Why using GORGY TIMING solutions?
Transcription
Why using GORGY TIMING solutions?
9th INSTRUCTIONS HANDBOOK Time, synchronization systems and communication displays. www.gorgy-timing.com/en Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 2/48 Summary 1 2 3 4 5 6 7 8 9 Sources of external synchronization......................................................................................................................................................................... 6 1.1 Transmission of time satellite reference ............................................................................................................................................................. 6 1.2 Transmission of the reference time by radio transmitters ................................................................................................................................... 6 1.3 Other sources of external synchronization: ........................................................................................................................................................ 6 Modes of transmission of time.................................................................................................................................................................................. 7 Operation of time distribution ................................................................................................................................................................................. 10 3.1 Wire time distribution …................................................................................................................................................................................... 10 3.2 Wireless distribution… ..................................................................................................................................................................................... 12 3.3 Time synchronization over network… .............................................................................................................................................................. 13 3.4 Mixed time distribution … ................................................................................................................................................................................ 14 Choosing a suitable type of transmission ............................................................................................................................................................... 15 Applications : Key points and patterns types .......................................................................................................................................................... 17 5.1 Banks ........................................................................................................................................................................................................... 18 5.2 Broadcast - Radios/Televisions .................................................................................................................................................................... 20 5.3 Power plants ................................................................................................................................................................................................ 22 5.4 Schools - Universities ................................................................................................................................................................................... 24 5.4.1 Schools (schools, colleges) .................................................................................................................................................................... 24 5.4.2 Universities ............................................................................................................................................................................................ 26 5.5 Hospitals, Clinics .......................................................................................................................................................................................... 28 5.6 Hotels ........................................................................................................................................................................................................... 30 5.7 Industries, Offices......................................................................................................................................................................................... 32 5.8 Swimming-pools ........................................................................................................................................................................................... 34 5.9 Air transportation .......................................................................................................................................................................................... 36 5.10 Railways ....................................................................................................................................................................................................... 38 Equipment description............................................................................................................................................................................................ 40 6.1 Comparative table (input synchronization, outputs, power supplies, sizes…) .................................................................................................. 40 6.2 Technical cards ............................................................................................................................................................................................... 42 Standards and regulations ..................................................................................................................................................................................... 43 7.1 ISO Certification .............................................................................................................................................................................................. 43 7.2 Compliance of products with EC ...................................................................................................................................................................... 43 7.3 ROHS Compliance .......................................................................................................................................................................................... 43 References ............................................................................................................................................................................................................ 44 Contacts ................................................................................................................................................................................................................ 45 Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 3/48 Our profession changes …. Recent developments in cabled, optical and wireless networks have fundamentally changed our profession and offer new possibilities that are more economical, more accurate and easier to implement. Only a short time ago, time distribution by GORGY TIMING consisted solely of displaying the time on a clock and supplying time to computers on a serial port. This world is now completely obsolete, we have entered the age of time synchronization on communication networks (Ethernet, Internet and wireless WIFI and WIMAX). This has had a profound, irreversible impact: the nature of synchronization exchanges is wider and faster and distance is no longer an obstacle. GORGY TIMING, French manufacturer, has been the most fervent supporter of the standardization of time transmission with a view to transparency and customer satisfaction. The present catalogue has been compiled to show how our profession has progressed and help you chose the application that best meets your requirements. Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 4/48 Why using GORGY TIMING solutions? Global product offer Led digital clocks, Analog clocks, Time servers, time centres, Telecom synchronization units. Inter operable solution Use of international standards and protocols. Flexible, reliable, 24/7 availability solutions Hot Plug, redundancy, power saving, modularity. Services Hot Line, site assistance commissioning, warranty extension, training, site acceptance test, factory acceptance test. Reduced costs of installation use of existing network, wireless solution, battery or POE supply. Know-how over 35 years experience. ISO Certification French manufacturing Products proposed and schemes are not restrictive examples. Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 5/48 1 Sources of external synchronization... For a greater accuracy, our quartz time bases can be synchronized by several external synchronization sources. 1.1 Transmission of satellite time reference Synchronization by GPS satellites. The GPS (Global positioning System) consists of 24 satellites that continuously broadcasts signals on the frequency 1.575 ghz provide the location and timing, for military and civilian sectors. A specific antenna receives these time messages in UTC (Universal Time Coordinated) Good reception with a minimum of three satellites can achieve a better than one microsecond accuracy. 1.2 Transmission of the reference time by radio transmitters The radio-synchronization is based on receiving time signals from transmitters : • France Inter Radio France 162kHz sinus waves, • DCF 77,5kHz (Germany), • MSF 60 kHz (UK), • WWVB 60kHz (USA), • JJY 8000-15000 kHz (Japon). The time signals are received in local time and include a complete message : hour, minute, second, date, day of week, month, year, daylight saving time. The remote active antenna of our master clock systems, allows them to automatically get time and date, and daylight saving time. 1.3 • • • • • • • Other sources of external synchronization: AFNOR NFS 87500 - IRIG B NTP (Net Time Protocol) PTP (Precision Time Protocol) ASCII SMPTE EBU DHW (Wireless time distribution) Pulse signal Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 6/48 2 Modes of transmission of time... The time servers must synchronize the clocks and the network of a company without being dependent on proprietary technology from a single manufacturer. • Impulse Transmission This mode of electrical transmission of time is old (1897).GORGY TIMING recommend it only to synchronize a few clocks or upgrade existing installations. • RS485 Transmission code This network transmission code allows to carry the time on a phone pair with shielding screen. GORGY TIMING has now dropped it in favour of the Afnor NFS 87500/Irig B standard time code . Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 7/48 • AFNOR NFS 87500 - IRIG B Transmission code This code standardized in time message and frequency allows customers to choose freely between several clocks suppliers to find the timing devices that suits the best to their requirements .This amplitude modulated code can now transmit the time to more than 250 clocks up to 40 km on a simple telephone cable. This code has the advantage of having no interference on surrounding lines and it is not subject to industrial and electrical interferences. • IRIG DCLS transmission This simplified code contains the Irig -B time message, but without modulation. The range is limited to a few hundred meters. • SMPTE EBU code transmission Standardized code for synchronization of video and audio signals in audio-visual applications Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 8/48 • PPS Transmission Pulse Per Second, broadcasting of time signals at programmable intervals. • NTP Transmission The Network time protocol (RFC 1305) transmitted over TCP/IP, calculates and corrects the deviation of data propagation time on local or remote networks. (cabled Ethernet or Wi-fi atmospheric networks). • PTP Transmission This Precision Time Protocol (IEEE 1588-2002) on TCP/IP corrects the deviation of propagation time using the principle of hardware timestamps to achieve accuracy of several nanoseconds. • DHW Transmission The Afnor standard time information is transmitted via radio waves on frequency 869.525 MHz EN300-2201(EU), FCC15.249(US), EN301.489, it has a range of 5 km in a free field and limited to a 250m radius subject to the composition of the building structure. Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 9/48 3 Operation of time distribution 3.1 • Wire time distribution … Impulse ☺ • Low prices for analog receiver clocks. Advice • Labourious commissioning. • Manual time setting of receiver clocks in case of cut-off line • High installation costs due to wiring • Interference on nearby phone lines. • Old mode of transmission, nearly obsolete. Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications To be proposed on small installations, up to 10 clocks on a maximum distance of 800m, or upgrading existing impulse set-ups... 10/48 • AFNOR NFS 87500/IRIG B code ☺ • Time synchronization without manual intervention • Standardized AFNOR code. • Reduced installation costs by using a pair available on a phone cable or optical fibre • Ability to transport time over long distances • No interference on of phone lines nearby Advice… • higher unit price per analog clock than with impulse. • Wiring Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications To be proposed on installations containing between 10 and 250 clocks with a distance up to 40km per output line of clocks. 11/48 3.2 • Wireless distribution… DHW : Wireless time distribution ☺ • Easy installation and lower installation costs (no wiring in DHW ) • Standardized time message . • Advice… • Coverage limited to a radius of 250m (for radius > 250m, repeaters are required) • Reception of the signal conditioned by the structure of the building No apparent cable. Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications To recommend for extensions of existing installations in case wiring is not allowed. This type of transmission requires expertise on site by one of our technicians to control that the frequency is received correctly in the whole building . 12/48 3.3 • Time synchronization over network… Ethernet and WIFI ☺ • Use of the existing computer network. • Standard protocol NTP RFC 1305. • Reduced installation costs. • POE power supply (Power Over Ethernet). Standard POE 802.3. • Synchronization of computer network and other networkconnected devices (our slave clocks are available in NTP version) • Reliability and easy implementation of system • A significant quantity of clocks and connected devices. • Supervision of products connected to the network via SNMP • Encryption MD5 Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications Advice… • Higher unit price of the clocks. Innovative solution to recommend on new facilities or facilities with an Ethernet network. 13/48 3.4 Mixed time distribution … ☺ • • Ideal for buildings expansion or renovation Flexibility of implementation Advice… • Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications Different clock versions to manage To recommend on extensions or “multifunctional “ applications to meet specific requirements. 14/48 4 Choosing a suitable type of transmission The diversity of our products combined with different modes of time transmission such as Afnor, NTP, wireless… can meet the needs of our customers and be adapted to different types of buildings. Each application has a solution: • For a new construction, it is possible to anticipate the wiring for power supply and for time code transmission. • In that case, we can use either Afnor or NTP. • As part of renovation of a building, it is possible to anticipate a wired time distribution if the cable already exists , or by radio (DHW) if it isn’t possible wiring. • A NTP synchronization with POE (IEEE 802.3af) power supply is more appropriate if the building is equipped with an Ethernet network. • In some cases, it is possible to have a mixed solution : Afnor + NTP or NTP + DHW . GORGY TIMING products can meet all these requirements . Our offer consists of : • Master clocks and time servers, whose main functions are to synchronize computer devices, distribute time to clocks, trigger ringtones, activate dry contacts. • Analog and digital clocks (interior and exterior) for time display, with NTP, DHW, AFNOR NFS87500 receivers • Dynamic communication displays. It is necessary to establish a diagnosis, analyse the state of the building structure and the quantity of clocks to be installed, in order to choose the transmission mode and the type of products that suits the best to your needs in compliance with international standards. Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 15/48 Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 16/48 5 Applications : Key points and patterns types Banks Broadcast – Radio/Television Power plants Schools - Universities Hospitals, clinics Hotels Industries, offices Swimming- pools Air transport Railways If your application does not appear in this list, contact our sales department : gorgy@gorgy-timing.fr 33 4.76.30.48.20 Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 17/48 5.1 Banks Today, the banks are diversifying. They are not just managing the accounts but also insurance or estate, hence they need to inform their customers about their activities It is important for a bank with several offices to have the identical time on all these sites and the ability to display information in real time. With the growing development of E-commerce and the account management via internet, the bank must secure their systems and date accurately their data exchanges, to avoid litigation. In trading rooms, it is necessary to display the exact time on all different trading places. Key points • • • • • • Display identical time on the clocks and on all equipment connected to the computer network Synchronize the computer network. Display official time throughout the building (trading rooms, offices, agencies…) Give time of different time zones on a same display. Saving energy: programming of lighting, heating, airing… Distribute and display information in real time to agents and customers (video, commercials, pictures…) Suggested equipment (non exhaustive list) • • • • • • Modular time centre : RT4000 Time server : LEDI NETWORK Programmer master clock : RTCP09 Digital LEDI clocks and analog HANDI clocks for interior and exterior LEDI WORLD clocks (with time zones) Communication displays : LEDICOM Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 18/48 • Typical installation : banks Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 19/48 5.2 Broadcast - Radios/Televisions On the radios and televisions, blackouts for national and regional programming must be perfectly synchronized, speaking time has to be displayed and timed by accurate time bases .Time allotted to journalists is planned. National radios give a precise time signal every hour. Mobile digital television requires great accuracy and frequency stability to guarantee changeover from one transmitting cell to next without interruption. Key points • • • • • • • • Generate and display Time Code. Read time instantly and view the remaining time.. Have silent clocks. Time the speaking time (counting up and down) Display identical time on the clocks and on all equipment connected to the computer network Synchronize the computer network Saving energy : programming of lighting, heating, ventilation… Distribute and display information in real time Suggested equipment (non exhaustive list ) • • • • • • Modular time centre : RT4000 Time server : LEDI NETWORK Programmer master clock : RTCP09 Digital LEDI clocks for interior and exterior LEDI WORLD clocks (with time zones) Communication displays Installations of timing system for recording van : PLEASE CONTACT US Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 20/48 • Typical installation : broadcast, radio/televisions Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 21/48 5.3 Power plants Electrical power requirements must correspond as precisely as possible with production. Load-shedding has to be triggered and synchronized with great accuracy and these occurrences must be precisely dated. More than ever before, power stations need to be regulated by extremely accurate time /frequency servers. The timing requirements are made on several accuracy levels : a) Events dating : accuracy 1 to 10 ms This dating is done at source (synchronizing each PLC). The event is dated at its detection by the PLC or the tilt-disturbance recorder. This timing at source is also called “fine timing”. b) Load management: accuracy inferior to 1 µs. Synchronization of electrical blackouts during periods of peak load-shedding consists in the voluntary shut-down (manually or automatically) one or a few consumption loads determined in advance in a power network in response to an abnormal situation, in order to maintain network integrity and to reduce blackouts. The cuts of these elements must be made respecting a very precise timing because of voltages and currents to be handled. c) Sale of Energy : accuracy about 100ms As result of energy deregulation, it was, necessary to design and deploy a new information system for counting, remote servers and record energy meters, installed on all input and output points of the transportation system. They communicate data to the servers in real time. This equipment located in different locations must be perfectly synchronised. The synchronization requirements are used to monitor power grids, including frequency changes 50 or 60Hz. Key points • • • • Display identical time on the clocks and on all equipment connected to the computer network Synchronize the computer network. Distribute accurate and safe time Distribute and display information in real time Suggested equipment (non exhaustive list) • • • • • • Modular time centre : RT4000 Module NT509 for RT4000 - sector frequency management 50 or 60 Hz Time server : LEDI NETWORK Frequency generator: OSA – Accuracy 2.048 MHz as per G.703-13 Digital LEDI clocks for interior and exterior Communication displays Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 22/48 • Typical installation : power plants Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 23/48 5.4 Schools - Universities 5.4.1 Schools, colleges GORGY TIMING master clocks synchronize GORGY TIMING receiver clocks, displaying the time in classrooms , corridors, library and playground, and they also can synchronize the computer networks with time servers. The programming units GORGY TIMING can trigger the ringtones at the beginning and at the end of the course but also enable to save energy by schedule programming for heating or lighting . GORGY TIMING offers a wide range of master clocks and receiver clocks. Communication between the school , the students , or students parents, goes via text displays to display information. Key points • • • • • • Display identical time in all the buildings (classrooms, corridors, playground, gymnasium…) Program ringtones, door openings. Display information in real time for teachers, students and parents. Reply with compliant clocks to standards for resistance to fire (EN60.950 et CEI60.950) Synchronize computer network and all connected devices. Make energy savings, by schedule programming of lighting, heating, ventilation… Suggested equipment (non exhaustive list) • • • • • • Time servers : LEDI NETWORK Programmer master clock: RTCP09 Digital LEDI clocks and analog HANDI clocks for interior and exterior LEDICA LCD (hour, date and temperature display) LEDI WORLD clocks ( with time zones) Communication displays : LEDICOM Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 24/48 • Typical installation : schools, colleges Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 25/48 5.4.2 Universities Universities or campus gather several distant buildings, it is important to limit the wiring and to use existing cables such as Ethernet network. GORGY TIMING offers both time servers and clocks on the Ethernet , the used time protocol is NTP, much safer and more accurate that the SNTP. It is, then possible to monitor the clocks and peripherals from a single location via the GT supervision software. Key points • • • • • • • Display identical time in all the buildings (classrooms, corridors, outside, cafeteria, library, gymnasium…) Program ringtones. Synchronize computer network and all connected devices. Display speaking time (counting up and down) Make energy savings, by programming of lighting, heating, ventilation… Display information in real time for teachers and students Reply with compliant clocks to standards for resistance to fire (EN60.950 et CEI60.950) Suggested equipment (non exhaustive list) • • • • • • • Time centre : RT4000 Time server : LEDI NETWORK Programmer master clock : RTCP09 Digital LEDI clocks and analog HANDI clocks for interior and exterior LEDICA LCD (time display, date and temperature) LEDI WORLD clocks (with time zones) Communication display Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 26/48 • Typical installation : universities Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 27/48 5.5 Hospitals, Clinics Hospital staff need to have the official time, operating theatres require specific timer clocks to meet the new hygiene and security standards. All the operational equipment from the PABX for call management, to communication recorders and computer network, must be perfectly synchronized, thereby, they have a precise chronology of the progress in rescue operations. The schedule of lighting, ventilation, heating can make energy savings. GORGY TIMING equipment, master clocks, time servers, synchronize the receiver clocks that display time in different offices, corridors, rooms, the lobby, operating theatres, and synchronize security pass, communication display, telephony… GORGY TIMING communication displays help disseminate information both for patients, visitors and hospital staff. Key points • • • • • • • Reply with compliant clocks to standards for resistance to fire (EN60.950 et CEI60.950) and hygiene standards.. Time the rescue operations (counting up and down) Display identical time on the clocks and on all equipment connected to the computer network Synchronize the computer network Display identical time throughout the building (operating theatres, recovery rooms, maternity …) Make energy savings, by scheduled programming of lighting, heating, ventilation…. Disseminate and display information in real time for hospital staff, patients, and visitors Suggested equipment (non exhaustive list) • • • • • • Time centre : RT4000 Time server : LEDI NETWORK Programmer master clock : RTCP09 Digital LEDI clocks and analog HANDI clocks for interior and exterior LEDI 7.S Hospital – flush mount case, front safety glass, wired touch remote control with stopwatch function Communication display Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 28/48 • Typical installation : hospitals, clinics Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 29/48 5.6 Hotels Customers need to know the time and date when they are at the reception, in the dining room, conference rooms and in their own room. They also wish to receive information in real time during their visit, being informed of an offer or an event. Key points • • • • • Display identical time on the clocks and all the equipment connected to computer network. Synchronize computer network and call management Make energy savings, schedule by programming of lighting, heating, ventilation… Reply with clocks compliant to standards for resistance to fire (EN60.950 et CEI60.950) Disseminate and display information in real time for the staff and the customers (commercials, seminars, photos…) Suggested equipment (non- exhaustive list) • • • • • • • Time server : LEDI NETWORK Programmer master clock : RTCP09 Digital LEDI clocks and analog HANDI clocks for interior and exterior Double display clocks LEDI NIGHT LEDICA LCD clock( hour, date and temperature display) LEDI WORLD (display several time zones) Communication displays : LEDICOM Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 30/48 • Typical installation : hotels Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 31/48 5.7 Industries, Offices The technology of time synchronization and network computing move on together to provide simpler solutions and more secure timing references. It also helps to unify the timing fordifferent systems in one building or in companies with remote sites. The master clocks and GORGY TIMING time servers synchronize the receiving clocks, secure data exchange, synchronize secure computer networks to avoid data loss information or overwriting files. Our systems can also achieve energy savings, it is possible to have control over lighting, ventilation, heating activity… Key points • • • • • • Display identical time on the clocks and all the equipment connected to computer network. Trigger ringtones in workshops. Have robust materials. Reply with compliant clocks to standards for resistance to fire (EN60.950 et CEI60.950) Make energy savings, schedule by lighting, heating, ventilation programming … Disseminate and display information in real time for the staff and the customers (videos, photos, announce a visitor…) Suggested equipment (non- exhaustive list) • • • • • • • Modular time centre : RT4000 Time server : LEDI NETWORK Programmer master clock : RTCP09 Digital LEDI clocks and analog HANDI clocks for interior and exterior LEDICA LCD clock (hour, date and temperature display) LEDI WORLD (display different time zones) Communication displays : LEDICOM Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 32/48 • Typical installation : industries, offices Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 33/48 5.8 Swimming-pools Due to high humidity, the pools must be equipped with waterproof and robust materials. The public need to know the water temperature for the different basins. This information can be relayed to the lobby through multi-zones displays. Key points • • • • • • • • Timing events Display air and pools temperature. Have robust and waterproof material. Display identical time on the clocks and all the equipment connected to computer network. Synchronize the computer network Make energy savings, by schedule programming of lighting, heating , ventilation… Disseminate and display information in real time for the staff and the visitors (videos , text , photos …) Reply with clocks compliant to standards for resistance to fire (EN60.950 et CEI60.950) Suggested equipment (non- exhaustive list) • • • • • Time server : LEDI NETWORK Programmer master clock : RTCP09 Digital LEDI clocks and analog HANDI clocks for interior and exterior LEDIPOOL clock (display time, pools and air temperature) Communication display Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 34/48 • Typical installation : swimming-pools Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 35/48 5.9 Air transportation Air traffic sustains a strong growth and requires a precise dating of time information in the control towers, airport terminals, and on board aircraft to ensure safety in the airspace and for good traffic flow. The solutions developed by GORGY TIMING engineering design department and our sales teams are based on 35 years of experience in this field. Today, more than 1 000 international airports are equipped with our synchronization systems. Synchronization requirements in ATM are on several levels : • • • • • A reliable time information, a redundant equipment . A quick and easy maintenance, thanks to the Hot-Plug modular system. A 24/7 availability for the systems. A warranty for perennity of equipment for over 10 years. The transportation of UTC and local time on network. Key points • • • • • • • Display identical time on the clocks and all the equipment connected to computer network. Synchronise the computer network. Display official time and GMT in the control towers and terminals. Reply to sensitive applications with secured hardware. Date events . Disseminate and display information in real time for the staff and the passengers (video , information, security…). Reply with compliant clocks with fire standards (EN60.950 et CEI60.950) Suggested equipment (non- exhaustive list) • • • • • • • • Modular time centre RT4000 High time bases accuracy Time server : LEDI NETWORK Desk clock : LEDI 1/S Programmer master clock : RTCP09 Digital LEDI clocks for interior and exterior LEDI WORLD (display different time zones) Communication displays Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 36/48 • Typical installation : air transportation Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 37/48 5.10 Railways In the subways…. Today, the trains circulate without driver, the operator needs a very accurate time for its telecom infrastructure and passengers information. In the telecommunications SDH / ATM / SONET : The flow of communication is constantly increasing. For efficient and reliable encoding /decoding, real-time images, videos and sounds, time servers/ frequency are used with nanoseconds accuracy. This level of precision is required to generate these frequencies 10 Mz , 5 MHz, and 2.048MHz. Our products control and synchronize information flow (voice, data , sound) via network. The technology of time synchronization and network computing approximate to provide simpler and more secure time solutions. Thanks to network of data processing Ethernet/ internet, the time information transmission link in the railways has been greatly simplified and standardized. The networks can carry time and data over long distances safely and thus allow large savings on wiring. In trains… The trains run over 300km/h, the synchronization technology deployed on the tracks and on trains must ensure a flawless reliable and secured process of time information for safe driving. The railways system needs the time at any level : Embedded clocks in the trains for on board equipment synchronization. On the platforms for passengers information. In the stations for the synchronization for BV(tickets), access control, monitoring CCTV… In power signal -box Energy position Key points • • • • • • Display identical time on the clocks of the different stations (on the platform, in the commercial areas, in station halls, in the relaxing areas) Synchronize computer network Display official time for the departure of the trains . Date events. Reply to sensitive applications with secured hardware. Disseminate and display information in real time for the staff and the passengers (video, security information…) Suggested equipment (non- exhaustive list) • • • • • • Modular time centre : RT4000 Time server : LEDI NETWORK Programmer master clock : RTCP09 Digital LEDI clocks for interior and exterior. Station platform clocks 93-700 and TGV clocks 94-500. Embedded clocks. Double display clocks. Communication displays: LEDICOM Communication display Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 38/48 • Typical installation :railways Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 39/48 6 Equipment description 6.1 Comparative table (input synchronization, outputs, power supplies, sizes…) Master clocks… RT93 RTCP09 RADIO TIMING NETWORK RTBGPS Wall mount enclosure Wall mount enclosure or Rack 19" 1U Wall mount enclosure Wall mount enclosure INPUT SYNCHRONIZATION Stand alone TDF/France Inter receiver DCF/Germany receiver Afnor NFS87500/IRIG B ASCII receiver GPS + antenna NTP DHW 869,525 Mhz - Radio (Wireless) OUTPUT OPTIONS Minute 24v // 1/2 minute Impulse reversed second Impulse Afnor NFS87500/IRIG B ASCII Dry contacts (programming) NTP DHW 869,525 Mhz - Radio (Wireless) POWER SUPPLY 230 VAC/50-60hz 115 VAC/50-60hz 12VDC 24 VDC 48 VDC 18-72 VDC 127 VAC/50-60hz DATA DISPLAY Hour/ minute Calendar SIZE / FIXING OPTION Tropicalization Available function Unavailable function Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 40/48 Time server… RT4000 LEDI Network ITS ITS Universal power supply LEDI 1/S/RK enhanced LEDI network NTP LEDI Network IN INPUT SYNCHRONIZATION TDF/France Inter receiver DCF/Germany receiver Afnor NFS87500/IRIG B NTP receiver GPS receiver GPS ANTENNA none 25m to 80m cable without lightening protection 25m to 80m cable with lightening protection POWER SUPPLY 230 vac /50-60hz 115vac/50-60hz 18-72 VDC 85-264vac/ 100-375 VDC 24 VDC 48 VDC telecom OSCILLATOR XO TCXO OCXO OUTPUT OPTIONS 1 alarm contact PIP 1000hz AFNOR 87500 AFNOR/ DCLS ASCII485 or 232 + PIP NTP/SNTP Server SMPTE/EBU Module SNMP/ http Supervision parallel or serial Impulse minute FTM Module (frequency supervision) SIZES Rack 19" 1U Rack 19" 3U OPTIONS Tropicalization Available function Unavailable function Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 41/48 6.2 Technical cards All our datasheets are available on www.gorgy-timing.com or upon request by contacting our sales department. Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 42/48 7 Standards and regulations 7.1 ISO Certification GORGY TIMING is certified ISO 9001. Certification ISO 14001. 7.2 Compliance of products with EC GORGY TIMING products are in compliancy with: • Directive 2004/108/CE of the European Parliament and Council of 2004 December the 15 , on approximation of laws of Members States relating to electromagnetic compatibility and repealing Directive 89/336/EEC th • Directive 2006/95/CE of the European Parliament and Council of 2006 December the 12th, concerning the approximation of laws of Members States relating to electrical equipment designed for us within certain voltage limits. This compliance is presumed reference to the following standards: 7.3 • NF EN 55024 • NF EN 55022 B class • NF EN 60950-1 Limits and methods of measurement of immunity features of A.T.I. – (Ed 1999 January ) Amended by NF EN 55024/A1 (2002 February) Amended by NF EN 55024/A2 (2003 April ) Limits and methods of measurement of feature radio interference produced by A.T.I. – (Ed 2007 March) Safety equipment information processing : general requirements : – (Ed. 2006 September) Supplemented by NF EN 60950-22 for equipment to be installed outside (2006 September) ROHS Compliance Unleaded. Attestations and certificates available on request. Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 43/48 8 References AIRPORTS SUBWAYS - TRAMWAYS ROISSY 2 / PARIS – ORLY SUD/ PARIS NICE : MARIGNANE /MARSEILLES SATOLAS/LYON - MONTPELLIER - TOULOUSE - CORSICA - BRUSSELS/BELGIUM FRANKFURT/GERMANY – COPENHAGEN/DENMARK –SPATA NEW INT’L AIRPORT ATHENS/GREECE- P.PORTY LOTNIZCY WARSAW/POLAND DUBLIN/SHANNON/CORK - IRELAND BARCELONA/PAMPELONA - SPAIN VILNIUS - PALANGA/ LITHUANIA GATWICK AIRPORT - UK -HELSINSKI ATC AIRPORT - FINLAND - NICOSIA ATC AIRPORT CYPRUS - LIEGE AIRPORT /BELGIUM SEYCHELLES – ST DENIS/ST PIERRE (Reunion Island) - MAURITIUS SRI LANKA AIRPORT - MALDIVES CIVIL AVIATION - SOUTH AFRICA : DURBAN, PORT ELIZABETH, BLOMFONTAINE BUJUMBURA-BURUNDI / DAKAR- SENEGAL / COTONOU - BENIN / DOUALA –YAOUNDE - CAMEROON / BANGUI - ZAIRE - ABIDJAN IVORY COAST / BURKINA FASO LIBREVILLE MYENGUE GABON - TABARKA- MAROCO / TUNIS CARTHAGE - TUNISIA -ANTANARIVO MADAGASCAR - NOUAKCHOTT-MAURITANIA / DAHRAN - SAUDI ARABIA - TRIPOLI BENGHAZI LYBIA / CAIRO - EGYPT - JORDAN AIRPORTS - KUWAIT INTERNATIONAL AIRPORT HONG KONG INTERNATIONAL AIRPORT LORAK-SHANGI SINGAPORE INTERNATIONAL AIRPORT DAVAO INTERNATIONAL AIRPORT Philippines UJUNG PENDANG AIRPORT/JAKARTA – INDONESIA CAMBOGIA AIRPORT - PHU MUY / NO BAI INT’L AIRPORTS VIETNAM - CHENGDU AIRPORT SANYA AIRPORT / CHINA - SRI LANKA INTERNATIONAL AIRPORT LAHORE KARACHI PAKISTAN -MELBOURNE/VICTORIA/BRISANE AIRPORTS AUSTRALIA (10 Sites) - NEW ZEALAND AIRPORTS (5 Sites) - TAHITI – POLYNESIA AIRPORT / NOUMEA CALEDONIAN AIRPORT BACOLOD SILAY AIRPORT - PHILIPPINES PARIS - MARSEILLES – LILLE - STRASBOURG ST ETIENNE – GRENOBLE – NANTES – LYON - CAEN - VAL D’ORLY - TURINO ITALY - CAIRO - EGYPT MRT HONG KONG - LRT SINGAPORE – SENKANG/PUNGGOL LINES - LRT MANILA PHILIPPINES - KAOHSIUNG MRT RED AND ORANGE LINES - TAIWAN AFRICA – MIDDLE EAST RAILWAYS PARIS - RENNES - POITIERS - LYON CLERMONT FERRAND - St ETIENNE LIMOGES - MONTPELLIER - LILLE DUNKERQUE - METZ - CHAMBERY - ANNECY - STRASBOURG - NICE - GRENOBLE MONTPELLIER - CARCASSONNE - BEZIERS TOULOUSE - PERPIGNAN - MARSEILLES RENFE BARCELONA/ MADRID / SEVILLA / VALENCIA SPAIN - BELIORUSSIA RAILWAYS AMERICA Airports HALIFAX CANADA - CHICHUAHUA – HERMOSILLO AIRPORTS - MEXICO ARUBA CARRIBEAN ISLAND - RIO DE JANEIRO BAZIL SANTIAGO DE CHILE – CHILE ST PIERRE & MIQUELON ISLAND - CARACAS VENEZUELA Subways-Tramways NEW YORK TRANSPORTATION -MEXICO C.V. MEXICO - SAO PAULO BRAZIL - METRO DE SOFIA BULGARIE RADIO & TV EURONEWS LYON - CANAL PLUS PARIS - AB PRODUCTIONS PARIS - ANTENNE 2 PARIS FRANCE 3 REGIONS (MORE THAN 30 STATIONS) - TF1 - RTL - TELE SATELLITES RADIO FRANCE – RFO – RFI - NRJ - FUN RADIO - RADIO NOSTALGIE - FRANCE INTER FRANCE MUSIQUE - EUROPE 1 - EUROPE 2 RADIO MONTE CARLO PARIS RADIO MONTE CARLO MONACO - SFP – ARTE Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications PARIS - SUD RADIO TOULOUSE - M6 – LA CINQ RADIO FOURVIERE – KTO - PARABOLE REUNION ANTENNE REUNION - RADIO RUNDFUNK BERLIN NSR – NDR - ZDF - ARD - MCI - RS 2 WDR SDR SWF - SAT 1 – ORF - PRO 7 - RADIO FFN BAYERISCHER RUNDFUNK - RTL PLUS - RTL TV DEUTSCHLANDFUNK - INFORADIO BERLIN ANTENNE BAYERN ANTENNE 2 - DELTA RADIO RIAS BERLIN - DEUTSCHE WELLE - SACHSEN RADIO – FUNKHAUS BERLIN - RADIO HAMBURG ANTENNE SACHSEN – AKK HAMBURG SAARLANDISCHER RUNDFUNK – SENDER FREIES BERLIN – HESSISCHER RUNDFUNK ANTENNE BRANDENBURG - INSTITUT FUR RUNDFUNKTECHNIK – FERNSEHSTUDIO MUNCHEN – MITTELDEUTSCHER RUNDFUNK – RADIO 100.6 MEDIEN - BAYERISCHE RUNDFUNKWERBUNG -OSTDEUTSCHER RUNDFUNK BRANDENBURG - RADIO ZET WARSCHAU - SENDER EUROPA 1 - RTBF RTL – ANTENNE CENTRE - RADIO PRAHA - RADIO FREE EUROPE CZECH REPUBLIC / RTV SLOVEJINA.DANISH TV. FINNISH BROADCASTING COMPANY - HELLAS SOUND - RAI – TELE MONTE CARLO – RTI MILANO RTL MILANO BETANEWSTELE P4 - NORVEGIAN BROADCASTING - RADIO Z RADIO MUZIKA - RADIODIFUSAO PORTUGUESAIMPRESSA LIVRES – RADIO COMERCIAL AUVIDSCIENFITICO - RADIO CATALUNYA SGT MADRID - RNE BARCELONA / MADRID – ANTENNA 3 - NRJ STOCKHOLM – NATIONAL OPERA STOCKHOLM - SWISS RADIO INT’L BERN – RADIO SUISSE ROMANDE -SWISS RADIO LAUSANNE / GENEVA – EUROPEAN BROADCASTING UNION/GENEVA - EDI ROMANIA MOSCOW RADIO – RUSSIAN TV CHANNEL. – NOUA RADIO – EUROPA 2 - BBC – RADIO TV MBC(MUNHWA BROADCASTING CORP) KOREA HINDUSTAN TIMES RADIO - INDIA BUDAPEST HUNGARY - EDINBURG / DUBLIN HOSPITALS/UNIVERSITY CENTRE HOSPITALIER DE RENNES HOPITAL BECKER CENTRE HOSPITALIER UNIVERSITAIRE DE GRENOBLE CLINIQUE MUTUALISTE GRENOBLE CENTRE HOSPITALIER DE VOIRON CENTRE HOSPITALIER D’ANNECY HOSPICES CIVILS DE LYON UNIKLINIK HEIDELBERG UNIKLINIK FREIBURG HENRICH HEINE UNI Dusseldorf ST JOSEF KANKENFHAUS WIPPERFURT ST GEORG KRANKEHAUS IN WUPPERTAL KRANKENHAUS Bonn KRANKENANSTALTEN OFFENBURG KRANKENHAUS SALEM Heildelberg KRANKENHAUS KREFLED UNIVERSITATSKRANKENHAUS EPPENDORF UNIVERSITY CENTRE HOSPITAL CAIRO EGYPT - ST GEORGES HOSPITAL BEYROUTH LEBANON - FRANCO VIETNAMESE HOSPITAL HO CHI MINH VIETNAM - SAN SALVADOR HOSPITAL - AI AIN HOSPITAL – UAE AMERICAN SCHOOL OF NUMBAI – INDIA STADIUMS ISTANTUL STADIUM PORTO – LISBONNE STADIUMS BEYROUTH STADIUM TUNIS CARTHAGE STADIUM STADE OF FRANCE – ST DENIS 44/48 9 CONTACTS GORGY TIMING SAS Quartier Beauregard 38350 La Mure d'Isère - France Phone: +33 476 30 48 20 Fax: +33 476 30 85 33 Technical support : 0892 68 70 68 (0,337 euro TTC/min) By e-mail : Trade service : gorgy@gorgy-timing.fr Support : support@gorgy-timing.fr Export service : export@gorgy-timing.fr Commercial subsidiaries: GORGY TIMING GMBH Östliche Rheinbrückenstr. 50 D-76187 Karlsruhe - DEUTSCHLAND FON 0721/60156 FAX 0721/695259 info@gorgy-timing.de GORGY TIMING Spain World Trade Center - Edificio Este, 6ª Plta. C/ Moll de Barcelona, s/n 08039 Barcelona – ESPAÑA Tel: +34 93 508 83 53 Fax: +34 93 508 83 54 gorgy@gorgy-timing.es Yantai Polaris Gorgy Timing Technology Co., Ltd 240 Beima Road, Yantai, Shandong, China Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 45/48 Notes Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 46/48 Ref. : GP_UK-V1.0 GORGY TIMING – non contractual pictures, subject to any modifications 47/48
Similar documents
TIME SERVERS - Gorgy Timing
synchronization input (GPS, IRIG…) as well as an internal clock based on a precise oscillator. Time broadcast is made possible thanks to the NTP network protocol. As well as an NTP output, GORGY TI...
More information