Vent-A-Hood specifications sheet
Transcription
Vent-A-Hood specifications sheet
SPECIFICATION SHEETS SUBJECT TO CHANGE WITHOUT NOTICE UNDER CABINET SUBJECT TO CHANGE WITHOUT NOTICE UNDER CABINET RANGE HOOD SPECIFICATIONS PRH6-K Halogen lights only. This model not available with heat lamps. This model only available in Black, Biscuit, Gunsmoke, Stainless Steel, or White. Custom sizes not available. The VP521 transition is available for top vent applications at an additional charge. 7” 7 ½” 10” Connection Diagrams (24”, 30", 36", & 42" Widths) ” 3¼ Recommended Mounting Height* Electrical Electrical *Exceeding recommended mounting height may compromise performance. Electrical/Mechanical Specifications For Blower Units Model K250 (Top Vent) K250 (Back Vent) Volts Amps Hz RPM 115 115 3.2 3.2 60 60 1550 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 250 375 223 220 190 220 330 215 195 180 Minimum Round Duct Size 7" (38 in.2) 7" (38 in.2) Sones# 7.4 7.4 All K-Series hoods have two halogen lights. • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1109A C UL R US UNDER CABINET RANGE HOOD SPECIFICATIONS SLH6-K Halogen lights only. This model not available with heat lamps. This model only available in Black, Biscuit, Gunsmoke, Stainless Steel, or White. Custom sizes not available. The VP521 transition is available for top vent applications at an additional charge. 7” 7 ½” 10” Connection Diagrams (24”, 30", 36", & 42" Widths) ” 3¼ Recommended Mounting Height* Electrical Electrical *Exceeding recommended mounting height may compromise performance. Electrical/Mechanical Specifications For Blower Units Model K250 (Top Vent) K250 (Back Vent) Volts Amps Hz RPM 115 115 3.2 3.2 60 60 1550 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 250 375 223 220 190 220 330 215 195 180 Minimum Round Duct Size 7" (38 in.2) 7" (38 in.2) Sones# 7.4 7.4 All K-Series hoods have two halogen lights. • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1109A C UL R US UNDER CABINET RANGE HOOD SPECIFICATIONS NP9/NPH9/PR9/PRH9/SL9/SLH9 “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected models. 12” 12” 9” 4” WID TH 12” 9” 2” WID TH ” 21 NP9/NPH9 9” 2” WID TH ” 21 PR9/PRH9 SL9/SLH9 Connection Diagram (30” - 48” Widths) 5 ¼” 1 ¾” 1 �⁄�” Wall Side 5 ½” Wall Side Vent Hole Electrical 3 ¼” Recommended Mounting Height* 5 ¼” Vent Holes 1 ¾” 6” Outlet Soffit 8” Outlet Electrical 9” 600 CFM B200 Dual Blower (Top View) (Top View) 8’ Ceiling 300 CFM B100 Single Blower Connection Diagram (42” - 48" Widths) 10” Round 7 �⁄��” 5 ½” Wall Side Cabinets Centerline of Hood Centerline of Hood 7 �⁄��” ” 21 24”-27” 10” Round 1 ¾” 1 �⁄�” 36” Vent Holes 17 ½” Electrical (2) 5 ¼” Centerline of Hood 8” Outlet 6” Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blower (Top View) *Exceeding recommended mounting height may compromise performance. VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) 10” OR 12” Round Connection Diagram (48” Width) 11” 11” 5 ½” 12” Round 5 ½” Vent Holes 1 ¾” 16 ½” 8” Outlet 5 ¼” 8” Outlet 12” Round Wall Side Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round 3” 1200 CFM Double B200 Dual Blowers (Top View) VP563 Transition (Optional) For B400 (Double B200 Dual Blowers) VP562/VP563 transition centers outlet over top of hood Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals Volts Amps* Hz RPM 115 115 115 115 1.5 2.9 4.4 5.8 60 60 60 60 1550 1550 1550 1550 CFM CFM CFM Minimum Round • CFM Sones# SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6 * Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A C UL R US UNDER CABINET RANGE HOOD SPECIFICATIONS F/XR9/XRH9 “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected models. 12” 12” 9” ” 2¼ WID TH 9” ” 2¼ ¾” O ffse t WID TH ” 21 F (Fluorescent Lights Only) XR9/XRH9 Connection Diagram (30” - 48” Widths) 5 ¼” 1 ¾” 1 �⁄�” Wall Side 5 ½” Wall Side Vent Hole Electrical 3 ¼” Recommended Mounting Height* 5 ¼” Vent Holes 1 ¾” 6” Outlet Soffit 8” Outlet Electrical 9” 600 CFM B200 Dual Blower (Top View) (Top View) 8’ Ceiling 300 CFM B100 Single Blower Connection Diagram (42” - 48" Widths) 10” Round 7 �⁄��” 5 ½” Wall Side Cabinets Centerline of Hood Centerline of Hood 7 �⁄��” ” 21 24”-27” 10” Round 1 ¾” 1 �⁄�” 36” Vent Holes 17 ½” Electrical (2) 5 ¼” Centerline of Hood 8” Outlet 6” Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blower (Top View) *Exceeding recommended mounting height may compromise performance. VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) 10” OR 12” Round Connection Diagram (48” Width) 11” 11” 5 ½” 12” Round 5 ½” Vent Holes 1 ¾” 16 ½” 8” Outlet 5 ¼” 8” Outlet 12” Round Wall Side Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round 3” 1200 CFM Double B200 Dual Blowers (Top View) VP563 Transition (Optional) For B400 (Double B200 Dual Blowers) VP562/VP563 transition centers outlet over top of hood Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals Volts Amps* Hz RPM 115 115 115 115 1.5 2.9 4.4 5.8 60 60 60 60 1550 1550 1550 1550 CFM CFM CFM Minimum Round • CFM Sones# SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6 * Add 2.5 amp for each warming light and 0.5 amp for each halogen light. The F hood is available with fluorescent lights only (one per single or dual blower) and the XR9/XRH9 is available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A C UL R US UNDER CABINET RANGE HOOD SPECIFICATIONS SL6/SLH6 “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected models. ” 12 2” 6” 9” WID TH 6” 19 ½” SL6/SLH6 Connection Diagram (30” - 48” Widths) 5 ¼” 1 ¾” 1 �⁄�” Wall Side 5 ½” Wall Side Vent Hole Electrical 3 ¼” Recommended Mounting Height* 5 ¼” Vent Holes 1 ¾” 6” Outlet Soffit 8” Outlet Electrical 600 CFM B200 Dual Blower (Top View) (Top View) Connection Diagram (42” - 48" Widths) 10” Round 7 �⁄��” 5 ½” 6” 8’ Ceiling 300 CFM B100 Single Blower Wall Side Cabinets Centerline of Hood Centerline of Hood 7 �⁄��” 9” Sloped Bottom 21”-24” 10” Round 1 ¾” 1 �⁄�” 36” Vent Holes 17 ½” Electrical (2) 5 ¼” Centerline of Hood 8” Outlet 6” Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blower (Top View) *Exceeding recommended mounting height may compromise performance. VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) 10” OR 12” Round Connection Diagram (48” Width) 11” 11” 5 ½” 12” Round 5 ½” Vent Holes 1 ¾” 16 ½” 8” Outlet 5 ¼” 8” Outlet 12” Round Wall Side Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round 3” 1200 CFM Double B200 Dual Blowers (Top View) VP563 Transition (Optional) For B400 (Double B200 Dual Blowers) VP562/VP563 transition centers outlet over top of hood Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals Volts Amps* Hz RPM 115 115 115 115 1.5 2.9 4.4 5.8 60 60 60 60 1550 1550 1550 1550 CFM CFM CFM Minimum Round • CFM Sones# SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6 * Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hood is available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A C UL R US WALL MOUNT SUBJECT TO CHANGE WITHOUT NOTICE WALL MOUNT RANGE HOOD SPECIFICATIONS NP18/NPH18/NPX18/NPXH18/PR18/PRH18/PRX18/PRXH18/SL18/SLH18/SLX18/SLXH18 “H” in part number indicates halogen lighting. WBAR warming light bar is available on selected models (included on NP Series). X in part number indicates 27” depth. 12” 12” 12” 18” 18” 18” 6” 4” 4” 4” - 2 7” NP X - 2 P N WID TH 4” - 2 7” PR X - 2 R P WID TH NP(X)18/NP(X)H18 (Includes WBAR warming light bar) PR(X)18/PR(X)H18 SL(X)18/SL(X)H18 Connection Diagrams (30” - 48” Widths) 5 ¼” 1 ¾” 1 �⁄�” Wall Side 5 ½” Wall Side Vent Hole 6” Outlet 3 ¼” Recommended Mounting Height* 5 ¼” Optional Duct Cover Vent Holes 1 ¾” Electrical 8” Outlet Electrical 600 CFM B200 Dual Blower (Top View) (Top View) 8’ Ceiling 300 CFM B100 Single Blower Connection Diagram (42” - 60" Widths) 10” Round 7 �⁄��” 5 ½” Wall Side 18” Centerline of Hood Centerline of Hood 7 �⁄��” 4” - 2 7” SL X - 2 L S WID TH 30” 10” Round 1 ¾” 1 �⁄�” 36” Vent Holes 17 ½” Electrical (2) 5 ¼” Centerline of Hood 8” Outlet 6” Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blower (Top View) VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) *Exceeding recommended mounting height may compromise performance. 10” OR 12” Round Connection Diagram (48” - 66" Widths) 11” 11” 5 ½” 12” Round 5 ½” Vent Holes 1 ¾” 16 ½” 8” Outlet 5 ¼” 8” Outlet 12” Round Wall Side Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round 3” 1200 CFM Double B200 Dual Blowers (Top View) VP563 Transition (Optional) For B400 (Double B200 Dual Blowers) Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals Volts Amps* Hz RPM 115 115 115 115 1.5 2.9 4.4 5.8 60 60 60 60 1550 1550 1550 1550 VP562/VP563 transition centers outlet over top of hood CFM CFM CFM Minimum Round • CFM Sones# SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6 * Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B C UL R US WALL MOUNT RANGE HOOD SPECIFICATIONS DA18/DAH18/PWV18/PWVH18/XR18/XRH18/XRX18/XRXH18 “H” in part number indicates halogen lighting. WBAR warming light bar is available on selected models. X in part number indicates 27" depth. 12” 12” 12” 18” 3” 18” 3” 1½ ” Off set WID TH 18” ” Off set WID TH ” 24 1” O 4” 1½ WID TH ” 24 DA18/DAH18 PWV18/PWVH18 Connection Diagrams (30” - 48” Widths) 5 ¼” 1 ¾” 1 �⁄�” Wall Side 5 ½” Wall Side Vent Hole Electrical 3 ¼” 4” - 2 7” XR X - 2 XR XR(X)18/XR(X)H18 Recommended Mounting Height* 5 ¼” Vent Holes 1 ¾” 6” Outlet ffse t 8” Outlet Electrical Centerline of Hood Centerline of Hood 300 CFM B100 Single Blower 600 CFM B200 Dual Blower (Top View) (Top View) Connection Diagram (42” - 60" Widths) 7 �⁄��” 5 ½” Wall Side 10” Round 7 �⁄��” 10” Round 1 ¾” 1 �⁄�” Vent Holes 17 ½” Electrical (2) 5 ¼” Centerline of Hood 8” Outlet 6” Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blower (Top View) VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) 10” OR 12” Round Connection Diagram (48” - 66" Widths) 11” 11” 5 ½” 12” Round 5 ½” 16 ½” 8” Outlet 5 ¼” 8” Outlet 12” Round Wall Side Vent Holes 1 ¾” *Exceeding recommended mounting height may compromise performance. Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round 3” 1200 CFM Double B200 Dual Blowers (Top View) VP563 Transition (Optional) For B400 (Double B200 Dual Blowers) VP562/VP563 transition centers outlet over top of hood Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals Volts Amps* Hz RPM 115 115 115 115 1.5 2.9 4.4 5.8 60 60 60 60 1550 1550 1550 1550 CFM CFM CFM Minimum Round • CFM Sones# SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6 * Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0909A C UL R US WALL MOUNT RANGE HOOD SPECIFICATIONS CX30/CXH30/DA30/DAH30/PWV30/PWVH30/SL30/SLH30 “H” in part number indicates halogen lighting. WBAR warming light bar is available on selected models. 12” 12” 30” 3” 30” 3” 1½ ” Off set WID TH 12” 12” CX30/CXH30 ” Off set 4” 1½ 3” 1½ WID TH ” 24 30” 30” ” Off set WID TH ” 24 DA30/DAH30 WID TH ” 24 PWV30/PWVH30 SL30/SLH30 Connection Diagrams (30” - 48” Widths) 5 ¼” 1 ¾” 1 �⁄�” Wall Side 5 ½” Wall Side Vent Hole Electrical 3 ¼” Recommended Mounting Height* 5 ¼” Vent Holes 1 ¾” 6” Outlet ” 24 30” 8” Outlet Electrical Centerline of Hood Centerline of Hood 600 CFM B200 Dual Blower (Top View) (Top View) 8’ Ceiling 300 CFM B100 Single Blower 30” Connection Diagram (42” - 60" Widths) 7 �⁄��” 5 ½” Wall Side 10” Round 7 �⁄��” 10” Round 1 ¾” 1 �⁄�” 36” Vent Holes 17 ½” Electrical (2) 5 ¼” Centerline of Hood 8” Outlet 6” Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blower (Top View) *Exceeding recommended mounting height may compromise performance. VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) 10” OR 12” Round Connection Diagram (48” - 66" Widths) 11” 11” 5 ½” 12” Round 5 ½” Wall Side Vent Holes 1 ¾” 16 ½” 8” Outlet 5 ¼” 8” Outlet 12” Round Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round 3” 1200 CFM Double B200 Dual Blowers (Top View) VP563 Transition (Optional) For B400 (Double B200 Dual Blowers) Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals Volts Amps* Hz RPM 115 115 115 115 1.5 2.9 4.4 5.8 60 60 60 60 1550 1550 1550 1550 VP562/VP563 transition centers outlet over top of hood CFM CFM CFM Minimum Round • CFM Sones# SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6 * Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A C UL R US WALL MOUNT RANGE HOOD SPECIFICATIONS CW/CWH “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected models. 12” WI DT H 24” CW/CWH Connection Diagrams (30” - 48” Widths) 1 ¾” 1 �⁄�” Wall Side 5 ½” Wall Side Vent Hole 5 ¼” 1 ¾” Electrical 6” Outlet 3 ¼” Cabinets of Soffit Vent Holes 8” Outlet Electrical 12” Centerline of Hood Centerline of Hood 300 CFM B100 Single Blower 600 CFM Dual Blower (Top View) (Top View) 8’ Ceiling 5 ¼” Recommended Mounting Height* 30” Connection Diagram (42” - 60" Widths) 7 �⁄��” 5 ½” Wall Side 10” Round 7 �⁄��” 10” Round 1 ¾” 1 �⁄�” 36” Vent Holes 17 ½” Electrical (2) 5 ¼” Centerline of Hood 8” Outlet 6” Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blower (Top View) *Exceeding recommended mounting height may compromise performance. VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) 10” OR 12” Round Connection Diagram (48” - 66" Widths) 11” 11” 5 ½” 12” Round 5 ½” Vent Holes 1 ¾” 16 ½” 8” Outlet 5 ¼” 8” Outlet 12” Round Wall Side Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round 3” 1200 CFM Double B200 Dual Blowers (Top View) VP563 Transition (Optional) For B400 (Double B200 Dual Blowers) Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals Volts Amps* Hz RPM 115 115 115 115 1.5 2.9 4.4 5.8 60 60 60 60 1550 1550 1550 1550 VP562/VP563 transition centers outlet over top of hood CFM CFM CFM Minimum Round • CFM Sones# SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6 * Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hood is available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B C UL R US WALL MOUNT RANGE HOOD SPECIFICATIONS TLH (Halogen Lights) Not available with heat lamps. TILT (Fluorescent Light) Not available with heat lamps. Cut Out For Top Vent Cut Out For Back Vent Door Panel Must Be Supplied By Cabinet Maker Hinge 1” From Top H DT WI 24 ¼” Door Panel Can Overhang 24 ¼” 11 21 Bevel Minimum1 ¼” Long ¼” Or Less o Mounting Holes For Door Panel ¼” 8¼ Door Panel Specifications TLH/TILT ” Recommended Mounting Height* Connection Diagrams (30” - 48” Widths) 5 ¼” 1 ¾” 1 3⁄8” Wall Side 5 ½” Wall Side Vent Hole 5 ¼” 1 ¾” Electrical 6” Outlet 3 ¼” Cabinets or Soffit Vent Holes 8” Outlet Electrical 24 ¼” Centerline of Hood Centerline of Hood 600 CFM B200 Dual Blower (Top View) (Top View) Channel For Mounting Strip 36” 13 ½” 13 ½” 23 ¾” 10 ¾” 24 ¼” 24 ¼” 10 ¾” 12 ½” Cut Out For Back Vent 8’ Ceiling 300 CFM B100 Single Blower 11 ¼” Left End Back View of Hood *Exceeding recommended mounting height may compromise performance. Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual Volts Amps Hz RPM 115 115 1.5 2.9 60 60 1550 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 300 450 273 245 225 600 900 531 480 430 Minimum Round Duct Size 6" (28 in.2) 8" (50 in.2) Sones# 5.4 6.5 * Add 0.5 amp for each halogen light. Hood is available with a single fluorescent light or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0409A C UL R US EURO-STYLE WALL MOUNT SUBJECT TO CHANGE WITHOUT NOTICE EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS PD14/PDH14/SLD14/SLDH14 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. 10” 10” OPTIONAL DUCT COVER HEIGHT OPTIONAL DUCT COVER 10” 8” 2 5⁄ HEIGHT 10” 3” 14” 14” WID TH WID TH ” 21 ” 21 PD14/PDH14 SLD14/SLDH14 30” model is limited to B100 single blower only Connection Diagram (30" - 48" Widths) 1 ¾” 1 7⁄8” Wall Side Recommended Mounting Height Blower Exhaust Outlet Vent Hole 6" Round 14" Electrical 5 ¼” 6" Outlet Optional Duct Cover or Soffit 5" 14” Centerline Of Hood (Front View) 8’ Ceiling 300 CFM B100 Single Blower (Top View) 24” Connection Diagram (36”- 48” Widths) 5 ½” Wall Side 5 ¼” Blower Exhaust Outlet 1 ¾” 36” 8" Round Vent Holes 5" 14" 8” Outlet Electrical Centerline of Hood (Front View) 600 CFM B200 Dual Blower *Exceeding recommended mounting height may compromise performance. (Top View) Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual Volts Amps* Hz RPM 115 115 1.5 2.9 60 60 1550 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 300 450 273 245 225 600 900 531 480 430 Minimum Round Duct Size 6" (28 in.2) 8" (50 in.2) Sones# 5.4 6.5 * Add 0.5 amp for each halogen light. Hood is available with a single fluorescent light or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A C UL R US EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS EP(X)18/EP(X)H18/NEP(X)18/NEP(X)H18/SEP(X)18/SEP(X)H18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. 12” 12” OPTIONAL DUCT COVER HEIGHT OPTIONAL DUCT COVER 18” 4” WID TH 12” OPTIONAL DUCT COVER 18” 4” WID TH 4” - 2 7” EP X - 2 P E EP(X)18/EP(X)H18 12” HEIGHT 12” HEIGHT 12” 18” 3” WID TH ” 24 ” P - - 27 E N PX NE NEP(X)18/NEP(X)H18 ” 24 ” P - 27 SE PX SE SEP(X)18/SEP(X)H18 (X) in part number indicates 27” depth Connection Diagram (36" - 48" Widths) 5 ½” Wall Side Recommended Mounting Height* 5 ¼” Optional Duct Cover Vent Holes 1 ¾” 18” 8” Outlet Electrical 8’ Ceiling Centerline of Hood 600 CFM B200 Dual Blower (Top View) 30” Blower Exhaust Outlet 9" 8" Round 36” 18" *Exceeding recommended mounting height may compromise performance. (Front View) Electrical/Mechanical Specifications For Blower Units Model B200 Dual Volts Amps* Hz RPM 115 2.9 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 600 900 531 480 430 Minimum Round Duct Size 8" (50 in.2) Sones# 6.5 * Add 0.5 amp for each halogen light. Hood is available with a single fluorescent light or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A C UL R US EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS EP(X)T18/EP(X)TH18/NEP(X)T18/NEP(X)TH18/SEP(X)T18/SEP(X)TH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover sold separately). Optional duct covers available in standard and custom sizes. HEIGHT 18” 4” WID TH 14” 26” OPTIONAL DUCT COVER 18” 4” WID TH ” 24 ” T - 27 EP XT EP EP(X)T18/EP(X)TH18 26” OPTIONAL DUCT COVER HEIGHT 14” 26” HEIGHT 14” OPTIONAL DUCT COVER 18” 3” WID TH 4” - 2 7” PT - 2 NE PXT NE NEP(X)T18/NEP(X)TH18 4” - 2 7” PT - 2 SE PXT SE SEP(X)T18/SEP(X)TH18 (X) in part number indicates 27” depth Connection Diagram (42" - 66" Widths) Recommended Mounting Height 10" 12 �⁄�” 9 �⁄�” Wall Side 1 ¾” Optional Duct Cover 8 ½” Electrical (2) 18” 18" 10" Outlet Centered On Hood Top 900 CFM B200 Dual & B100 Single Blower (Top View) VP562 Standard Transition Installed (Front View) Connection Diagram (54” - 66” Widths) 8’ Ceiling Centerline Of Hood 30” 12" 1 ¾” 16 ½” 5 ½” 7 ½" Wall Side 7" 1 ¾” Electrical (2) 12" Outlet Centered On Top Of Hood 18" 36” Centerline Of Hood 1200 CFM Double B200 Dual Blowers VP563 Standard Transition Installed (Front View) (Top View) The transition shown (VP562 & VP563) is installed in the hood at the factory as a standard item. It will be located in the exact center of the duct cover (left to right & front to rear). Duct Cover (Top of Hood) *Exceeding recommended mounting height may compromise performance. 10" Dia. or 12" Dia. Transition Location "Centered" Electrical/Mechanical Specifications For Blower Units Model B200 Dual & B100 Single Two B200 Duals Volts Amps* Hz RPM 115 115 4.4 5.8 60 60 1550 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 900 1350 804 725 655 1200 1800 1062 960 860 Minimum Round Duct Size 10" (79 in.2) 12" (113 in.2) Sones# 6.3 6.6 * Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (one for each single or dual blower) or with halogen lights (3 lights: 42" - 53", 4 lights: 54" - 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B C UL R US CONTEMPORARY WALL MOUNT SUBJECT TO CHANGE WITHOUT NOTICE WALL MOUNT RANGE HOOD SPECIFICATIONS The VP521 transition is available for top vent applications at an additional charge. CWEH6-K Equipped with halogen lighting. This model not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. Available in painted and stainless steel finishes. Available in 30", 36", 42", and 48" widths only. OPTIONAL DUCT COVER 7” 7 ½” ” 10” CWEH6-K Connection Diagram Recommended Mounting Height* 3¼ (Top View) *Exceeding recommended mounting height may compromise performance. (Front View) Electrical/Mechanical Specifications For Blower Units Model K250 (Top Vent) Volts Amps* Hz RPM 115 2.2 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 250 375 223 220 190 Minimum Round Duct Size 7" (38 in.2) Sones# 7.4 * Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" & 36", 3 lights: 42" & 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1009A C UL R US WALL MOUNT RANGE HOOD SPECIFICATIONS GTH Equipped with halogen lighting. These models not available with heat lamps. Only available in stainless steel. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. Pot rail included. ” 12 The VP521 transition is available for top vent applications at an additional charge. OPTIONAL DUCT COVER 7” 12 ” 10” ” ½ 16 7 ½” 16 ” 1 ¾” ” 36 21 ” ” 10” GTH (36” Width Only) 3¼ Connection Diagram 1” Recommended Mounting Height* 3 ¼” x 10” Outlet Wall Side Optional Duct Cover 4 ½” 10” Centerline of Hood 8’ Ceiling Electrical 24” (Top View) Outlet 36” *Exceeding recommended mounting height may compromise performance. 6" NOTE: DUCT COVER EXTENDS 4” INTO TOP OF HOOD. (Front View) Electrical/Mechanical Specifications For Blower Units Model K250 (Top Vent) Volts Amps Hz RPM 115 3.2 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 250 375 223 220 190 Minimum Round Duct Size 7" (38 in.2) Sones# 7.4 All K-Series hoods have two halogen lights. • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B C UL R US WALL MOUNT RANGE HOOD SPECIFICATIONS Space Between Duct Covers OPTIONAL DUCT COVERS OPTIONAL DUCT COVER CWEH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with optional duct cover(s) (sold separately). Optional duct covers are available in standard and custom sizes. Width A 4" CWEH9-348 8" CWEH9-354 10" CWEH9-360 12" CWEH9-448 10" CWEH9-454 10" CWEH9-460 12" CWEH9-466 14" Model CWEH9-342 Connection Diagram (30”- 48” Widths) Connection Diagram (30”- 54” Widths) Recommended Mounting Height* Motor Cooling Vent Electrical Electrical 6" Round Motor Cooling Vent 8" Round 300 CFM B100 Single Blower 600 CFM B200 Dual Blower (Top View) (Top View) Connection Diagram (42”- 60” Widths) Model Motor Cooling Vent 8" Round 6" Round 900 CFM B200 Dual & B100 Single Blower (Top View) Width A Width B CWEH9-342 8" 8" CWEH9-348 10" 10" CWEH9-354 11" 11" CWEH9-360 12" 12" Outlet Spacing for 900 CFM Models Connection Diagram (48”- 66” Widths) Electrical (2) Motor Cooling Vent 8" Round 8" Round Model Width A Width B CWEH9-448 11" 11" CWEH9-454 11" 11" CWEH9-460 12" 12" CWEH9-466 13" 13" *Exceeding recommended mounting height may compromise performance. 1200 CFM Double B200 Dual Blowers Outlet Spacing for 1200 CFM Models Electrical/Mechanical Specifications For Blower Units (Top View) Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals Volts Amps* Hz RPM 115 115 115 115 1.5 2.9 4.4 5.8 60 60 60 60 1550 1550 1550 1550 CFM CFM CFM Minimum Round • CFM Sones# SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6 * Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1009A C UL R US WALL MOUNT RANGE HOOD SPECIFICATIONS CWLH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers are available in standard and custom sizes s (sold separately). Galley rail included. od Ho ds o FM Ho 0C M 90 00CF r fo 12 ide or ”W e f 26 “ Wid 34 12 ” 12 ” OPTIONAL DUCT COVER 4 ½” 12 ” 4 ½” OPTIONAL DUCT COVER 4 ½” 4 ½” ” 5¾ hs idt 8” Widths 4 & 2”, ” W ”, 4 48 36 2”, & , ” 4 0 - 3 6”, FM - 3 0 C 0CFM 0 3 60 9” 21 ” 3” hs idt s ” W idth 0 & 6 66” W 4”, -5 ,& M - 60” F 0C M 90 00CF 12 ” 5¾ 9” 21 ” 3” Recommended Connection Diagram (30”- 48” Widths) Connection Diagram (36”- 48” Widths) Mounting Height* 1 ¾” 5 ¼” ½” 1 ¾” Wall Side 4 ½” Wall Side 5 ¼” Vent Hole Vent Holes Electrical 1 ½” 6” Outlet Optional Duct Cover 5 ¼” Centerline of Hood Centerline of Hood 8” Outlet 600 CFM B200 Dual Blower (Top View) (Top View) 8’ Ceiling 300 CFM B100 Single Blower Connection Diagram (54”- 60” Widths) 7 �⁄��” 1 ¾” 1 �⁄�” 10” Round Vent Holes 10” Round 17 ½” 36” Electrical (2) 5 ¼” 6" Outlet Centerline of Hood 8" Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blower VP562 Transition (Optional) for B300 (B200 Dual & B100 Single Blower) (Top View) 11” 12” Round 11” 5 ½” 5 ½” 12” Round Wall Side Vent Holes 1 ¾” 16 ½” 8" Outlet 5 ¼” Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round 3” 1200 CFM Double B200 Dual Blowers (Top View) VP563 Transition (Optional) for B400 (For Double B200 Dual Blowers) Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals *Exceeding recommended mounting height may compromise performance. 10” OR 12” Round Connection Diagram (60”- 66” Widths) 8" Outlet 27” 7 �⁄��” 5 ½” Wall Side 9” Volts Amps* Hz RPM 115 115 115 115 1.5 2.9 4.4 5.8 60 60 60 60 1550 1550 1550 1550 VP562/VP563 transition centers outlet over top of hood CFM CFM CFM Minimum Round • CFM Sones# SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6 * Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A C UL R US WALL MOUNT RANGE HOOD SPECIFICATIONS XLH12 Equipped with halogen lighting. This model not available with heat lamps. Only available in stainless steel. Optional duct covers/finished duct available in standard and custom sizes (sold separately). ” 10 HOOD WITH OPTIONAL ROUND DUCT COLLARS AND FINISHED ROUND DUCT DUCT COVERS/FINISHED ROUND DUCT AND DUCT COLLARS PRICED SEPARATELY 10 ” 1” HOOD WITH OPTIONAL 10” X 10” DUCT COVER 12” 2” 15” ” 30 21 ” HOOD WITH OPTIONAL SQUARE DUCT COLLARS AND FINISHED ROUND DUCT ” 6 &3 2” LIP MAY BE BRASS, COPPER, STAINLESS STEEL, OR MIRROR STAINLESS STEEL XLH12 Connection Diagram (30” & 36” Widths) 1 ¾” 4 ½” Wall Side Blower Exhaust Outlet 5 ¼” Recommended Mounting Height* 8" Round Vent Holes 5 ¼” 12" 8” Outlet Electrical Optional Finished Duct Pipe 3" Centerline of Hood 12” (Front View) NOTE: WHEN PRICING CUSTOM FINISHED ROUND DUCT, INCLUDE THE 3” FINISHED ROUND THAT EXTENDS INTO TOP OF HOOD AND 1” THAT EXTENDS INTO CEILING (4” DUCT (REQUIRES TWO TOTAL.) TOTAL OVERALL HEIGHT CANNOT EXCEED 60” (10’ 8” CEILING). DUCT COLLARS) ROUND DUCT COLLAR SQUARE DUCT COLLAR Crimped Galvanized Connector 3” 1” Into Ceiling 10 12” For 7’ Ceiling 24” For 8’ Ceiling 36” For 9’ Ceiling Overall Height Of Finished Round Duct 24” 3” ” 10 10 ” 8’ Ceiling (Top View) ” ” 10 36” 10” x 10” SQUARE DUCT COVER 3” Into Hood 10” 10” HEIGHT 8” ROUND NOTE: TOP END OF FINISHED ROUND DUCT IS CRIMPED TO ALLOW FOR DUCT CONNECTION IN THE CEILING (CRIMP IS NOT INCLUDED IN THE OVERALL HEIGHT OF THE FINISHED ROUND DUCT). CUSTOM SIZES ALSO AVAILABLE *Exceeding recommended mounting height may compromise performance. NOTE: DUCT PIPE EXTENDS 3” INTO TOP OF HOOD AND 1” INTO CEILING. Electrical/Mechanical Specifications For Blower Units Model B200 Dual Volts Amps Hz RPM 115 3.9 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 600 900 531 480 430 Minimum Round Duct Size 8" (50 in.2) Sones# 6.5 Hood has two halogen lights. • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A C UL R US WALL MOUNT RANGE HOOD SPECIFICATIONS ZTH Equipped with halogen lighting. These models not available with heat lamps. Only available in stainless steel. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes (sold separately). Fixed pot rails included. OPTIONAL ” 12 ” 12 OPTIONAL DUCT COVER ” 12 OPTIONAL DUCT COVER 12 12 12 ” ” ” ” 18 ” 1” ” ” 18 ” 34 16 ” 1” 14 3⁄8” ” 36 24 ” ” 1” 14 �⁄�” DUCT COVER 12 16 ” 16 ” 18 16 ” 28 OPTIONAL DUCT COVER 14 �⁄�” ” 42 24 1” ” 48 24 ” ” 54 14 3⁄8” ” 24 ” ZTH Connection Diagram (36”- 48” Widths) 1 ¾” 4 ½” Wall Side 5 ¼” Blower Exhaust Outlet Vent Holes 5 ¼” Recommended Mounting Height* 8” Round Optional Duct Cover 14 �⁄�” 8” Outlet Electrical 14 �⁄�” 9” Centerline of Hood (Front View) 600 CFM B200 Dual Blower 8’ Ceiling (Top View) Connection Diagram (54” Width) 10” Round Wall Side 6 �⁄��" 8 �⁄��" 4 ½" 1 �⁄�" 30” 10” Round 1 ¾" 36” 17 ½” Vent Holes Electrical (2) 5 ¼" 6" Outlet Centerline Of Hood 8" Outlet 8” Round 900 CFM B200 Dual Blower & B100 Single Blower 8” Round 6” Round VP562 Transition (Optional) For B300 For B200 Dual and B100 Single Blower (Top View) Blower Exhaust Outlets 8” Round 2” *Exceeding recommended mounting height may compromise performance. NOTE:DUCT COVER EXTENDS 5 3/8” INTO TOP OF HOOD. 10”ROUND OR 12” 10” Round 6” Round 14 �⁄�” 9” VP562 transition centers outlet over top of hood (Front View) Electrical/Mechanical Specifications For Blower Units Model B200 Dual B200 Dual & B100 Single Volts Amps Hz RPM 115 115 4.9 6.4 60 60 1550 1550 CFM CFM CFM Minimum Round • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 600 900 531 480 430 8" (50 in.2) 900 1350 804 725 655 VP562: 10" (79 in.2) Sones# 6.5 6.3 Hood has four halogen lights (one light in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B C UL R US RETRO STYLE SUBJECT TO CHANGE WITHOUT NOTICE RETRO STYLE WALL MOUNT RANGE HOOD SPECIFICATIONS AH12 Halogen lights only. This model is not available with heat lamps. Painted round duct and ceiling collar are priced separately. 15” 16” 4” 12” WID TH Includes side wing panels and splash panel. Splash panel is 30” tall x hood width. 12” ” 27 2” x 2” Clipped Corners AH12 Recommended Mounting Height* Connection Diagram (30”- 48” Widths) 30” Model is Limited to B100 Single Blower Only Blower Exhaust Outlet 1 ¾” 1 7⁄8” Wall Side Optional Painted Round Duct 6" Round Vent Hole 2" Electrical 5 ¼” 6" Outlet 12” 12" Centerline Of Hood (Front View) 300 CFM B100 Single Blower 8’ Ceiling (Top View) Connection Diagram (36”- 48” Widths) 5 ½” Wall Side Blower Exhaust Outlet 5 ¼” 8" Round Vent Holes 1 ¾” 2" 36” 8” Outlet Electrical 33” 12" Centerline of Hood (Front View) *Exceeding recommended mounting height may compromise performance. Optional Ceiling Collars NOTE: DUCT PIPE EXTENDS 2” INTO TOP OF HOOD AND 1” INTO CEILING. 600 CFM B200 Dual Blower (Top View) Optional Painted Round Duct Crimped Galvanized Connector 1” Into Ceiling 11” 3” For 7’ Ceiling 15” For 8’ Ceiling 27” For 9’ Ceiling Overall Height Of Finished Round Duct 6 ¼” Diameter Opening ARC6 2” Into Hood 11” 8 1/4” Diameter Opening ARC8 Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual Volts Amps* Hz RPM 115 115 1.5 2.9 60 60 1550 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 300 450 273 245 225 600 900 531 480 430 Minimum Round Duct Size 6" (28 in.2) 8" (50 in.2) Sones# 5.4 6.5 * Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0908A C UL R US RETRO STYLE UNDER CABINET RANGEHOOD SPECIFICATIONS CLH9 Halogen lights only. 12” 9” 2” ½” Offset WID TH ” 21 CLH9 Connection Diagram (30” - 48” Widths) 5 ¼” 1 ¾” 1 �⁄�” Wall Side 5 ½” Wall Side Vent Hole 5 ¼” Vent Holes 1 ¾” Electrical 6” Outlet 3 ¼” Recommended Mounting Height* Soffit 8” Outlet Electrical Cabinets Centerline of Hood Centerline of Hood 9” 600 CFM B200 Dual Blower (Top View) (Top View) 8’ Ceiling 300 CFM B100 Single Blower Connection Diagram (42” - 48” Widths) 7 �⁄��” 5 ½” Wall Side 10” Round 7 �⁄��” 24”-27” 10” Round 1 ¾” 1 �⁄�” 36” Vent Holes 17 ½” Electrical (2) 5 ¼” Centerline of Hood 8” Outlet 6” Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blower (Top View) *Exceeding recommended mounting height may compromise performance. VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) 10” OR 12” Round Connection Diagram (48” Width) 11” 11” 5 ½” 12” Round 5 ½” Vent Holes 1 ¾” 16 ½” 8” Outlet 5 ¼” 8” Outlet 12” Round Wall Side Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round 3” 1200 CFM Double B200 Dual Blowers (Top View) VP563 Transition (Optional) For B400 (Double B200 Dual Blowers) VP562/VP563 transition centers outlet over top of hood Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals Volts Amps* Hz RPM 115 115 115 115 1.5 2.9 4.4 5.8 60 60 60 60 1550 1550 1550 1550 CFM CFM CFM Minimum Round • CFM Sones# SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6 * Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A C UL R US ISLAND SUBJECT TO CHANGE WITHOUT NOTICE ISLAND RANGE HOOD SPECIFICATIONS ISF18/ISFH18/ISL18/ISLH18/IXR18/IXRH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. 12 Bo ” Les tto s T m W han idt h ” 15 12 Bo ” Les tto s T m W han idt h ” 15 18” 18” 3” 1½ ”O WI 3” ffse t DT H 12 Bo ” Les tto s T m W han idt h ” 15 ” 27 WI DT H ISF18/ISFH18 ISL18/ISLH18 18” 4” 1” O ffse t WI 1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View) ” 27 DT H ” 27 IXR18/IXRH18 Connection Diagram (36” - 54”) Connection Diagram (60” - 66”) Centerline of Hood ¾” 2 �⁄�” 5” x 16” Exhaust Opening Electrical (2) Vent Holes Vent Holes ¾” 8" Transition Opening (2) 9" Above Top Of Hood Centerline Of Hood 550 CFM T200 Dual Blower 1100 CFM T2+ 200 Dual Blowers (Top View) (Top View) 30” 36” 9" 8" Round Optional Duct Cover 5" x 16" Exhaust Opening (2) 18” 8” Transition Opening 9” Above Top of Hood Electrical 2 �⁄�” Centerline Of Hood 11" 8’ Ceiling Centerline of Hood 11" Recommended Mounting Height* 8" Round 9" 18" 5" *Exceeding recommended mounting height may compromise performance. 16" VP565 Standard Transition Transition Installed (Included) (Side View) Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual Volts Amps* Hz RPM 115 2.9 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 550 900 507 471 431 Minimum Round Duct Size 8" (50 in.2) Sones# 6.0 * Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A C UL R US ISLAND RANGE HOOD SPECIFICATIONS PL18/PLH18/PLX18/PLXH18/PY18/PYH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. 12” 12 Bo ” Les tto s T m W han idt h ” 15 18” 18” 6” 3” WI DT H WI 1 ½” Connection Diagram (36” - 54”) 2 �⁄�” 11" 2 �⁄�” Centerline Of Hood 8” Transition Opening 9” Above Top of Hood Electrical 1 ½” �⁄��” Dia. Island Duct Cover Mounting Holes (Top View) ” 27 PY18/PYH18 Connection Diagram (60” - 66”) Centerline of Hood 5” x 16” Exhaust Opening ffse t DT H “X” in model number indicates 30” depth ¾” ”O 7” -2 ” PL - 30 X PL PL(X)18/PL(X)H18 Centerline of Hood 1½ Electrical (2) Vent Holes Vent Holes 11" Optional Duct Cover 5" x 16" Exhaust Opening (2) ¾” 18” 8" Transition Opening (2) 9" Above Top Of Hood Centerline Of Hood 1100 CFM T2+ 200 Dual Blowers (Top View) (Top View) 8’ Ceiling 550 CFM T200 Dual Blower 9" 8" Round Recommended Mounting Height* 30” 36” 8" Round 9" 18" 5" *Exceeding recommended mounting height may compromise performance. 16" VP565 Standard Transition Transition Installed (Included) (Side View) Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual Volts Amps* Hz RPM 115 2.9 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 550 900 507 471 431 Minimum Round Duct Size 8" (50 in.2) Sones# 6.0 * Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A C UL R US ISLAND RANGE HOOD SPECIFICATIONS ICX30/ICXH30/ISF30/ISFH30 “H” in part number indicates halogen lighting. These models not available with heat lamps. 12 Bo ” Les tto s T m W han idt h ” 15 12 Bo ” Les tto s T m W han idt h ” 15 30” 30” 1½ ”O WI 3” DT H ”O WI 2 1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View) Connection Diagram (36” - 54”) 11” 5" x 16" Exhaust Opening Vent Holes 7 ¾" ” 27 ISF30/ISFH30 Connection Diagram (60” - 66”) Centerline Of Hood Centerline Of Hood ffse t DT H 7” ICX30/ICXH30 Electrical 1½ ffse t 11” 5” x 16” Exhaust Opening (s) Centerline of Hood 8" Transition Opening 3” Below Top of Hood Vent Holes 30” 8” Transition Opening (2) 3” Below Top of Hood 7 ¼” Electrical (2) Centerline of Hood 550 CFM T200 Dual Blower 1100 CFM T2+ 200 Dual Blowers (Top View) (Top View) 3" 8" Round Recommended Mounting Height* 8’ Ceiling 3” 30” 36” 8" Round 30" *Exceeding recommended mounting height may compromise performance. 9" 5" 16" VP565 Standard Transition Transition Installed (Included) (Side View) Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual Volts Amps* Hz RPM 115 2.9 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 550 900 507 471 431 Minimum Round Duct Size 8" (50 in.2) Sones# 6.0 * Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A C UL R US ISLAND RANGE HOOD SPECIFICATIONS ISL30/ISLH30/PY30/PYH30 “H” in part number indicates halogen lighting. These models not available with heat lamps. 12 Bo ” Les tto s T m W han idt h ” 15 12 Bo ” Les tto s T m W han idt h ” 15 30” 30” 3” 3” DT H DT H ” 27 1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View) Connection Diagram (36” - 54”) Centerline Of Hood Vent Holes 7 ¾" ” 27 PY30/PYH30 Connection Diagram (60” - 66”) Centerline Of Hood 11” 5" x 16" Exhaust Opening ffse t WI ISL30/ISLH30 Electrical ”O 11” 8” Transition Opening (2) 3” Below Top of Hood 7 ¼” Vent Holes Electrical (2) Centerline of Hood 550 CFM T200 Dual Blower 1100 CFM T2+ 200 Dual Blowers (Top View) (Top View) 30” 36” 3" 8" Round 30” 5” x 16” Exhaust Opening (s) Centerline of Hood 8" Transition Opening 3” Below Top of Hood Recommended Mounting Height* 8’ Ceiling WI 1½ 8" Round 30" *Exceeding recommended mounting height may compromise performance. 9" 5" 16" VP565 Standard Transition Transition Installed (Included) (Side View) Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual Volts Amps* Hz RPM 115 2.9 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 550 900 507 471 431 Minimum Round Duct Size 8" (50 in.2) Sones# 6.0 * Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A C UL R US ISLAND RANGE HOOD SPECIFICATIONS CO/COH “H” in part number indicates halogen lighting. This model not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. ” 20” 14 OPTIONAL DUCT COVER ” 14 2 OPTIONAL DUCT COVERS 20” 3” 3” 12” WI 1½ ”O DT H 1½ WI ffse t DT H ”O ffse t 12” ” 27 1 ½” ” 1 ½” 5⁄16” Dia. 27 CO/COH Island Duct Cover Mounting Holes (Top View) Connection Diagram (36” - 54”) Connection Diagram (60” - 66”) Recommended Mounting Height* Centerline of Hood 11” Centerline of Hood ¾” 2 �⁄�” 5” x 16” Exhaust Opening Centerline of Hood 8” Transition Opening 9” Above Top of Hood Electrical Vent Holes 11” ¾” Electrical (2) Vent Holes Optional Duct Cover 5” x 16” Exhaust Opening (2) 8” Transition Opening (2) 9” Above Top of Hood 2 �⁄�” 12” 550 CFM T200 Dual Blower 1100 CFM T2+ 200 Dual Blowers (Top View) (Top View) 8’ Ceiling Centerline of Hood 30” 9" 8" Round 8" Round 36” 9" 12" 5" 16" VP565 Standard Transition Transition Installed (Included) (Side View) *Exceeding recommended mounting height may compromise performance. Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual Volts Amps* Hz RPM 115 2.9 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 550 900 507 471 431 Minimum Round Duct Size 8" (50 in.2) Sones# 6.0 * Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A C UL R US EURO-STYLE ISLAND SUBJECT TO CHANGE WITHOUT NOTICE EUROSTYLE ISLAND RANGE HOOD SPECIFICATIONS ISD18/ISDH18/PYD18/PYDH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. 12” 12” OPTIONAL DUCT COVER HEIGHT OPTIONAL DUCT COVER 12” 18” 3” WID TH HEIGHT 12” 18” 4” WID TH ” 27 ” 27 1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View) ISD18/ISDH18 PYD18/PYDH18 Connection Diagram (36" - 48" Widths) Recommended Mounting Height* Centerline Of Hood Optional Duct Cover 5" x 16" Exhaust Opening Centerline Of Hood 18” 7 ¾" Electrical 8" Transition Opening 8’ Ceiling Vent Holes 550 CFM T200 Dual Blower (Top View) 8" Round 30” 8" Round 36” 18" 9" 5" 16" VP565 Standard Transition Transition Installed (Included) (Side View) *Exceeding recommended mounting height may compromise performance. Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual Volts Amps* Hz RPM 115 2.9 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 550 900 507 471 431 Minimum Round Duct Size 8" (50 in.2) Sones# 6.0 * Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (one in front, one in back) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B C UL R US EUROSTYLE ISLAND RANGE HOOD SPECIFICATIONS EPI18/EPIH18/SEPI18/SEPIH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. 12” 12” 12” OPTIONAL DUCT COVER HEIGHT OPTIONAL DUCT COVER 18” 4” WID TH HEIGHT 12” 18” 3” WID TH ” 30 ” 30 1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View) EPI18/EPIH18 SEPI18/SEPIH18 Connection Diagram (36" - 48" Widths) Recommended Mounting Height* Centerline Of Hood Optional Duct Cover 5" x 16" Exhaust Opening Centerline Of Hood 18” 7 ¾" Electrical 8" Transition Opening 8’ Ceiling Vent Holes 550 CFM T200 Dual Blower 30” (Top View) 8" Round 8" Round 36” 18" 9" 5" *Exceeding recommended mounting height may compromise performance. 16" VP565 Stadard Transition Transition Installed (Included) (Side View) Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual Volts Amps* Hz RPM 115 2.9 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 550 900 507 471 431 Minimum Round Duct Size 8" (50 in.2) Sones# 6.0 * Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (one in front, one in back) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B C UL R US EUROSTYLE ISLAND RANGE HOOD SPECIFICATIONS EPIT18/EPITH18/SEPIT18/SEPITH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. 15” 15” OPTIONAL DUCT COVER HEIGHT OPTIONAL DUCT COVER 18” 4” WID TH 15” HEIGHT 15” 18” 3” WID TH ” 30 1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View) EPIT18/EPITH18 ” 30 SEPIT18/SEPITH18 Connection Diagram (48" - 66" Widths) Recommended Mounting Height* Centerline of Hood Optional Duct Cover Electrical (2) Vent Holes 7 ¾” 8” Blower Outlets Centerline of Hood 12" Transition Opening 2 ¼” Above Top of Hood 18” 8’ Ceiling 10 ½” 1100 CFM T400 Cluster Blower 30” (Top View) 2 ¼” 12" Round 12" Round 36” 11 ¼" 8" Round 18” 8" Round *Exceeding recommended mounting height may compromise performance. 8" Round VP564 Standard Transition Transition Installed (Included) (Side View) Electrical/Mechanical Specifications For Blower Units Model T400 Island Cluster Volts Amps* Hz RPM 115 5.8 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 1100 1800 998 855 774 Minimum Round Duct Size 12" (13 in.2) Sones# 6.4 * Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two in front, two in back) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B C UL R US CONTEMPORARY ISLAND SUBJECT TO CHANGE WITHOUT NOTICE ISLAND RANGE HOOD SPECIFICATIONS CIEH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with optional duct cover(s) (sold separately). Optional duct covers available in standard and custom sizes. OPTIONAL DUCT COVER 2 OPTIONAL DUCT COVERS CIEH9 (1100 CFM) CIEH9 (550 CFM) 1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View) Recommended Mounting Height* Connection Diagram (36”- 54” Widths) Centerline of Hood Centerline of Hood ¾” 5” x 16” Exhaust Opening 2 �⁄�” 9" 8" Round 8" Round 8” Transition Opening 9” Above Top of Hood Electrical Vent Holes 9" 9" 5" 16" 550 CFM T200 Dual Blower VP565 Transition Transition Installed (Top View) (Included) (Side View) *Exceeding recommended mounting height may compromise performance. Connection Diagram (60”- 66” Widths) 11” 11” Centerline of Hood 5” x 16” Exhaust Opening (2) ¾” Electrical (2) Vent Holes 9" 8" Round 8” Transition Opening (2) 9” Above Top of Hood 2 �⁄�” 8" Round 9" 9" Centerline of Hood 5" 16" 1100 CFM T2+200 Dual Blower VP565 Transition Transition Installed (Top View) (2 Included) (Side View) Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual Volts Amps* Hz RPM 115 2.9 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 550 900 507 471 431 Minimum Round Duct Size 8" (50 in.2) Sones# 6.0 * Add 0.5 amp for each halogen light. Hood is available with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1009A C UL R US ISLAND RANGE HOOD SPECIFICATIONS CILH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. Galley rail included. 14 ” ” 14 14 ” 14 ” OPTIONAL DUCT COVER 2 OPTIONAL DUCT COVERS 4 ½” 4” 4 ½” 4 ½” 4 ½” 3” 4” 3” 5 ¾” ” 20 ” 0” 5¾ ths 2 id ”W 54 30 ” FM 0C 5¾ 55 ” hs & 8”, 4 2”, -4 30 ” 5¾ -6 idt ”W 66 ” 1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View) CILH9 (550 CFM) FM 0C 0 11 0” & CILH9 (1100 CFM) Recommended Mounting Height* Optional Duct Cover Connection Diagram (42”- 54” Widths) Centerline of Hood ¾” 5” x 16” Exhaust Opening 2 �⁄�” 8" Round 8” Transition Opening 9” Above Top of Hood Electrical Vent Holes 9" 8" Round 8’ Ceiling Centerline of Hood 9” 9" 9" 5" 16" 550 CFM T200 Dual Blower VP565 Transition Transition Installed (Top View) (Included) (Side View) 36” *Exceeding recommended mounting height may compromise performance. Connection Diagram (60”- 66” Widths) 11” 11” Centerline of Hood 5” x 16” Exhaust Opening (2) ¾” Electrical (2) Vent Holes 30” 8" Round 8” Transition Opening (2) 9” Above Top of Hood 2 �⁄�” 9" 8" Round 9" 9" Centerline of Hood 5" 16" 1100 CFM T2+200 Dual Blower VP565 Transition Transition Installed (Top View) (2 Included) (Side View) Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual Volts Amps* Hz RPM 115 2.9 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 550 900 507 471 431 Minimum Round Duct Size 8" (50 in.2) Sones# 6.0 * Add 0.5 amp for each halogen light. Hood is available with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0908A C UL R US ISLAND RANGE HOOD SPECIFICATIONS IZTH Equipped with halogen lighting. These models not available with heat lamps. Only available in stainless steel. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. Pot rail included. OPTIONAL DUCT COVER OPTIONAL DUCT COVER ” 15 18 ” OPTIONAL DUCT COVER ” 22 15 ” ” ” 54 ” 42 14” 30 ” 22 15 ” ” 66 14” 30 ” OPTIONAL DUCT COVER ” OPTIONAL DUCT COVER ” 15 18 ” 15 ” ” 22 �⁄��” Dia. 1 ½” IZDC Island Duct Cover Mounting Holes (Top View) ” 60 ” 48 14” 30 14” 30 ” 14” 30 ” Recommended Mounting Height* Connection Diagram (42" - 48" Widths) 7" Centerline of Hood 8" Round 8" Round 5” x 16” Exhaust Opening Centerline of Hood Optional Duct Cover 21" 9" 6 ¼” Electrical 8” Transition Opening 7” Above Top of Hood Vent Holes 5" 14” 16" VP565 Transition Transition Installed (Top View) (Included) (Side View) 8’ Ceiling 550 CFM T200 Dual Blower Connection Diagram (54" - 66" Widths) 30” Centerline of Hood 10 ½” 9 ¼" 12" Round 12" Round Vent Holes 8” Blower Outlets 36” Centerline of Hood 23 ¼" 11 ¼" Electrical 6 ¼” 12” Transition Opening 9 ¼” Above Top of Hood 8" Round 8" Round 8" Round 1100 CFM T400 Cluster Blower VP564 Transition Transition Installed (Top View) (Included) (Side View) *Exceeding recommended mounting height may compromise performance. NOTE: DUCT COVER EXTENDS 2” INTO TOP OF HOOD. Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual T400 Island Cluster Volts Amps* Hz RPM 115 115 2.9 5.8 60 60 1550 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 550 900 507 471 431 1100 1800 998 855 774 Minimum Round Duct Size 8" (50 in.2) 12" (113 in.2) Sones# 6.0 6.4 * Add 0.5 amp for each halogen light. Hood is available with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808C C UL R US WALL MOUNT LINER SUBJECT TO CHANGE WITHOUT NOTICE WALL MOUNT LINER INSERT SPECIFICATIONS KHSLD LINER Halogen lights only. This model not available with heat lamps. This model only available in Black, Biscuit, Gunsmoke Gray, Stainless Steel, or White. The VP521 transition is available for top vent applications at an additional charge. 16 ½ ” AN S TH IDTH S E 5” L TOM W BOT 7” 2½ ” 6” 28 18” 34 3⁄8”, 3⁄8”, 7 ½” 8” 0 3⁄ 4 KHSLD ” 10” 3¼ Top Vent or Back Vent 3 ¼” x 10” Connection Diagrams (28 3/8", 34 3/8", & 40 3/8" Widths) Wall Cutout for Vertical Ducting Viewed from Above Recommended Mounting Height* Wall Cutout for Horizontal Ducting Viewed from Front Custom Enclosure 7⁄8" Top of Liner 2 5⁄8" Back of Liner 3 ½" 5" 5 1⁄8" 5 1⁄8" 5 1⁄8" Electrical 7" CL 6 ¼" CL 8’ Ceiling 6” 21”-24” 36” *Exceeding recommended mounting height may compromise performance. Electrical/Mechanical Specifications For Blower Units Model K250 (Top Vent) K250 (Back Vent) Volts Amps Hz RPM 115 115 3.2 3.2 60 60 1550 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 250 375 223 220 190 220 330 215 195 180 Minimum Round Duct Size 7" (38 in.2) 7" (38 in.2) Sones# 7.4 7.4 All K-Series hoods have two halogen lights. • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0909A C UL R US WALL MOUNT LINER INSERT SPECIFICATIONS BSLD/BHSLD LINER “H” in part number indicates halogen lighting. This model not available with heat lamps. 12” N THA TH ESS ID 6” L TOM W T BO 3” 12” 6 ”, 4 19 28 ¼” 3⁄8”, 34 3⁄8 40 3⁄8”, 3⁄8” BSLD/BHSLD Connection Diagram (28 3/8” - 40 3/8” Widths) 5 ¼” Recommended Mounting Height* 1 ¾” 1 3⁄8” Wall Side Custom Enclosure Vent Hole Electrical 6” Outlet 3 ¼” Centerline of Hood 12” 300 CFM B100 Single Blower 8’ Ceiling (Top View) Connection Diagram (28 3/8” - 46 3/8” Widths) 5 ½” Wall Side 5 ¼” Vent Holes 1 ¾” 24”-27” 36” 8” Outlet Electrical Centerline of Hood 600 CFM B200 Dual Blower *Exceeding recommended mounting height may compromise performance. (Top View) Connection Diagram (46 3/8” Width) 7 5⁄16” Wall Side 10” Round 7 5⁄16” 5 ½” 10” OR 12” Round 10” Round 1 ¾” 1 7⁄8” Vent Holes 17 ½” Electrical (2) 5 ¼” Centerline of Hood 8” Outlet 6” Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blower (Top View) VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) VP562/VP563 transition centers outlet over top of hood Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Volts Amps* Hz RPM 115 115 115 1.5 2.9 4.4 60 60 60 1550 1550 1550 CFM CFM CFM Minimum Round • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 300 450 273 245 225 6" (28 in.2) 600 900 531 480 430 8" (50 in.2) 900 1350 804 725 655 VP562: 10" (79 in.2) Sones# 5.4 6.5 6.3 * Add 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0609A C UL R US WALL MOUNT LINER INSERT SPECIFICATIONS BPSLD/BHPSLD LINER “H” in part number indicates halogen lighting. This model not available with heat lamps. 12” N THA TH ESS ID 6” L TOM W T BO 3” 12” 22 �⁄�”, 40 ”, �⁄�”, , 58 �⁄� 4 ” 3 �⁄�”, 2 �⁄� 28 �⁄�”, 5 4 �⁄�” 6 46 ½” BPSLD/BHPSLD Connection Diagram (28 3/8” - 52 3/8” Widths) 5 ½” Wall Side Recommended Mounting Height* 5 ¼” Vent Holes 1 ¾” Custom Enclosure 8” Outlet Electrical Centerline of Hood 12” 600 CFM B200 Dual Blower 8’ Ceiling (Top View) Connection Diagram (46 3/8” - 58 3/8” Widths) 7 �⁄��” 5 ½” Wall Side 10” Round 7 �⁄��” 27”-30” 10” Round 1 ¾” 1 �⁄�” Vent Holes 17 ½” 36” Electrical (2) 5 ¼” Centerline of Hood 8” Outlet 6” Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blower (Top View) VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) *Exceeding recommended mounting height may compromise performance. 10” OR 12” Round Connection Diagram (52 3/8” - 64 3/8” Widths) 11” 11” 5 ½” 12” Round 5 ½” Wall Side Vent Holes 1 ¾” 16 ½” 8” Outlet 5 ¼” 8” Outlet 12” Round Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round 3” 1200 CFM Double B200 Dual Blowers (Top View) VP563 Transition (Optional) For B400 (Double B200 Dual Blowers) VP562/VP563 transition centers outlet over top of hood Electrical/Mechanical Specifications For Blower Units Model B200 Dual B200 Dual & B100 Single Two B200 Duals Volts Amps* Hz RPM 115 115 115 2.9 4.4 5.8 60 60 60 1550 1550 1550 CFM CFM CFM Minimum Round • CFM Sones# SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6 * Add 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A C UL R US WALL MOUNT LINER INSERT SPECIFICATIONS BH340PSLB/B446PSLB/BH446PSLB LINER “H” in model number designates halogen lighting. BH340PSLB is available with halogen lights only. This model not available with heat lamps. 12” �⁄�” 40 �⁄�” 46 3” 12” Recommended Mounting Height* 22 Custom Enclosure ½” BH340PSLB/B446PSLB/BH446PSLB 12” Connection Diagram (40-3/8" Width) 5 ½” Wall Side 10” Round 7 �⁄��” 10” Round 8’ Ceiling 7 �⁄��” 1 ¾” 1 �⁄�” Vent Holes 17 ½” Electrical (2) 5 ¼” 6” Outlet Centerline of Hood 8” Outlet 8” Round 8” Round 6” Round 2” 900 CFM B200 Dual & B100 Single Blowers (Top View) 36” VP562 Transition (Optional) For B300 (B200 Dual & B100 Single Blowers) *Exceeding recommended mounting height may compromise performance. Connection Diagram (46-3/8" Width) 11” 12” Round 11” 5 ½” 5 ½” 10” OR 12” Round 12” Round Wall Side Vent Holes 1 ¾” 16 ½” 8” Outlet 5 ¼” 8” Outlet 27”-30” Centerline of Hood Electrical (2) 8” Round 8” Round 8” Round 3” 1200 CFM Double B200 Dual Blowers (Top View) VP563 Transition (Optional) For B400 Transition centers outlet (Double B200 Dual Blowers) over top of hood Electrical/Mechanical Specifications For Blower Units Model B200 Dual & B100 Single Two B200 Duals Volts Amps* Hz RPM 115 115 4.4 5.8 60 60 1550 1550 CFM CFM CFM Minimum Round • CFM Sones# SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" Duct Size 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6 * Add 0.5 amp for each halogen light. The B446PSLB is available with two fluorescent lights. Both models are available with three halogen lights. • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A C UL R US ISLAND LINER SUBJECT TO CHANGE WITHOUT NOTICE ISLAND LINER INSERT SPECIFICATIONS TSLE/THSLE “H” in part number indicates halogen lighting. This model not available with heat lamps. 15” AN TH DTH S S LE WI 12” TOM T BO 3” 12” ” 48 2”, ”, 4 36 27” TSLE/THSLE Connection Diagram (36” - 48” Widths) Recommended Mounting Height* Centerline Of Hood Centerline Of Hood 2 �⁄�” ¾” 5” x 16” Exhaust Opening Custom Enclosure 8” Transition Opening 9” Above Top of Hood Electrical Vent Holes 12” 550 CFM T200 Dual Blower 8’ Ceiling (Top View) 30” 9" 8" Round 8" Round 36” 9" 12" 5" 16" VP565 Standard Transition Transition Installed (Included) (Side View) *Exceeding recommended mounting height may compromise performance. Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual Volts Amps* Hz RPM 115 2.9 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 550 900 507 471 431 Minimum Round Duct Size 8" (50 in.2) Sones# 6.0 * Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (one in front, one in back) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B C UL R US ISLAND LINER INSERT SPECIFICATIONS TPSLE/THPSLE “H” in part number indicates halogen lighting. This model not available with heat lamps. 22” AN TH DTH S S LE WI 16” TOM T BO 3” 12” ” 6 ”, 6 , 48” 30” , 60 54” TPSLE/THPSLE Connection Diagram (48” - 66” Widths) Recommended Mounting Height* Centerline of Hood 1 ¾" Electrical (2) Custom Enclosure Vent Holes 8” Blower Outlets Centerline of Hood 5 ½" 12” 12" Transition Opening 11 ¼" Above Top of Hood 8’ Ceiling 10 ½" 1100 CFM T400 Cluster Blower (Top View) 12" Round 12" Round 30” 11 1/4" 36” 11 ¼" 12" 8" Round 8" Round *Exceeding recommended mounting height may compromise performance. 8" Round VP564 Standard Transition Transition Installed (Included) (Side View) Electrical/Mechanical Specifications For Blower Units Model T400 Island Cluster Volts Amps* Hz RPM 115 5.8 60 1550 CFM CFM CFM • CFM SP@0.0" Equivalent CFM SP@0.1" SP@0.2" SP@0.3" 1100 1800 998 855 774 Minimum Round Duct Size 12" (13 in.2) Sones# 6.4 * Add 0.5 amp for each halogen bulb. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B C UL R US
Similar documents
BROCHURE Female RR_COR Ok:Layout 1
COLL81 ABSOLUTE CAMELEON R E M OVA B L E FA C E S W I T H R E M OVA B L E L I P S
More informationElectrical and Ducting Specifications - Vent-A-Hood
Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce performance. Only use smooth, galvanized, metal duct. Observe local codes regarding special duct requireme...
More informationSunMaster new catalogue 2014/2015
Anti-days without sunshine Battery Battery Installation Battery life Wire 100%lighting throughout the year Human-friendly installation Overall performance
More information