Geoelectric and VLF electromagnetic survey on complex
Transcription
Geoelectric and VLF electromagnetic survey on complex
Versão online: http://www.lneg.pt/iedt/unidades/16/paginas/26/30/125 Comunicações Geológicas (2012) 99, 2, 95-100 ISSN: 0873-948X; e-ISSN: 1647-581X Geoelectric and VLF electromagnetic survey on complex aquifer structures, Central Sudan Pesquisa geoeléctrica e electromagnetica VLF em estruturas aquíferas complexas, Sudão Central N. E. Mohamed1*, H. Brasse2, M.Y. Abdelgalil1, K. M. Kheiralla1 Artigo original Original article Recebido em 15/11/2011 / Aceite em 11/05/2012 Disponível online em Maio de 2012 / Publicado em Dezembro de 2012 © 2012 LNEG – Laboratório Nacional de Geologia e Energia IP Abstract: The geophysical integration of the Geoelectric and Electromagnetic methods was applied to map the complex aquifer structures in northeast Nuba Mountains. The water flow is structurally controlled by the northwest-southeast extensional faults as one of several in-situ deformational patterns that are attributed to the collision of the Pan-African oceanic assemblage of the Nubian shield against the pre-Pan African continental crust to the west. This study involved the reconnaissance techniques of the horizontal electric profiling (HEP), vertical electrical soundings (VES), electrical resistivity tomography (ERT), in addition to the electromagnetic very low frequency-resistivity (VLF-R) profiling; to identify the major geological interfaces suspected to be faults/fractured zones. These VLF-R measurements were designed to be overlapped by the HEP, VES and ERT data to improve the reliability of the observed data and to provide better interpretation of the hydrogeological setting. This correlation is successfully delineated several fracture zones boundaries and new target aquifers in the study area. by the fractures that are attributed to the collision of the PanAfrican oceanic assemblage of the Nubian shield against the prePan African continental crust to the west (Vail, 1983 & 1985). The objectives of this study are twofold: to assess the integration of the geoelectric and the very low frequency electromagnetic data on the complex aquifer structure and to delineate new aquifer targets in the studied areas. The selected study area is bounded between latitude 11º - 12ºN, and 31º - 32ºE, and it consists of four big villages/small town which are: AlTrtr, AbuGeris, AlBetira, and AbuGebiha. Keywords: VLF, geoelectric, Nuba Mountains, Sudan. Resumo: Aplicou-se uma integração geofísica dos métodos geoeléctricos e electromagnéticos para mapear as complexas estruturas aquíferas no nordeste das Montanhas Nuba. O fluxo de água é controlado estruturalmente pelas falhas extensionais noroeste-sudeste, um dos muitos padrões de deformação in situ que são atribuídos à colisão do conjunto oceânico pan-africano para oeste. Este trabalho envolveu técnicas de reconhecimento do perfil eléctrico horizontal (HEP), sondagens elétricas verticais (VES), tomografia de resistividade eléctrica (ERT) para além de perfis de electromagnetismo de muito baixa frequência-resistividade (VLF-R) para identificar as principais interfaces geológicas suspeitas de serem zonas de falha/fracturação. Estas medições de VLF-R destinaramse a ser sobrepostas pelos dados de HEP, VES e ERT de modo a melhorar a fiabilidade dos dados observados e de modo a fornecer melhor interpretação do enquadramento hidrogeológico. Esta correlação delineou com sucesso várias zonas de fractura e novos alvos para a presença de aquíferos na área em estudo. Palavras-chave: VLF, geoeléctrico, Montanhas Nuba, Sudão. 1 Faculty of Petroleum and Minerals, AlNeelain University, Khartoum, Sudan. Fachrichtung Geophysik, Freie Universitaet Berlin, Germany. *Corresponding author /Autor correspondente: nuhazein@hotmail.com 2 Fig.1. The Nuba Mountains region lies ~550km from Khartoum in south Kordofan State. Fig.1. As Montanhas Nuba ficam a ~550km de Khartoum no sul do estado de Kordofan. 1. Introduction 2. Geology and Tectonic Setting The Nuba Mountains lies about 550km south west Khartoum (Fig.1) in South Kordofan State and occupies about 140.000km2. It is a crystalline basement uplift that is entirely surrounded by Mesozoic to Cenozoic rocks filling several graben (Browne & Fairhead, 1983). The groundwater flow is structurally controlled Studies by Vail (1973), Shaddad et al. (1979) and Sadig & Vail (1986) have established the basement divisions in the Nuba Mountains as: the high-grade gneisses in the west and the lowgrade volcano-sedimentary sequence to the east (Fig.2). The high-grade gneisses which are exposed as low outcrops overlain 96 N. E. Mohamed et al. / Comunicações Geológicas (2012) 99, 2, 95-100 in places by thick Quaternary sediments (Abdelsalam & Dawoud, 1991). The metamorphic and structural history of northeastern Nuba Mountains supports a pre-Pan-African age for the high-grade gneissic terrain. The Kabous ophiolitic melange (~10 km wide) separates the high-grade gneissic terrain from the low-grade volcano-sedimentary sequence, and it can be traced for more than 70 km in a NNE direction (Fig.2.). The low-grade volcano-sedimentary terrain occupied the eastern part of northeastern Nuba Mountains; where the four selected study areas are located; and is characterized by a thick sequence of poly deformed meta-sedimentary and metavolcanic rocks. Thicknesses of these units range from a few tens to a few hundreds of meters. The metamorphic mineral assemblages of the rocks indicate green schist facies grade of metamorphism. The superficial deposits exist in the Nuba mountains region as alluvial, which are head water sections of Wadies. The deposits are mainly composed of sands with some clayey lenses and the thickness of these alluvial may range from 8 to 25m. The gradient of the Wadies decreases downstream with increase in the clayey content, and the alluvial thickness increases and reach the maximum at 70m and increases towards the White Nile. The flow directions of these Wadies are related to the geology mentioned above and they generally follow the extensional fractures of NW-SE direction. Abdelsalam & Dawoud, (1991) studied the structural deformations of the northeastern Nuba Mountains which recorded three phases of deformation (D1, D2 and D3) that are almost completely destroyed the primary structures. The early phase D1 is characterized by overturned isoclinal folds associated with extensional lineation. D2 is the main phase and is characterized by tight, slightly overturned easterly verging folds dominates most of the southwestern part of the volcanosedimentary sequence. D3 is mainly cataclastic and forms E-W trending wrench faults and shear zones which can be traced over all northeastern Nuba Mountains. 3. Hydrogeology The Nuba Mountains region is characterized by a tropical summer climate (15°C - 35°C). Rainy seasons (April to October) re relatively longer compare to other parts of Kordofan State with an average annual rainfall 700 mm in the southern parts and 400 mm in the northern parts. The wadies flow NW towards the White Nile (Fig.2), which it is apparently structurally controlled by the NW-SE extensional faults as one of several in-situ deformational patterns in the study area. Due to the dominant sand dunes (qoz) west of the White Nile, it was difficult to know if the ground water flow in the study areas is well developed; i.e. reach the White Nile. The most pronounced drainage patterns are linear, angular and dense dendritic. The major seasonal wadies are: Tandik, AlBatha, Kabous, BanGadid, AbuRakuba, and AlTrtr. In addition to numerous minor wadies that are irregular and running parallel to the fault and joint systems of the basement complexes, which have considerable amounts of running water but it apparently seeps downs or highly evaporated during the rainy season. Potential groundwater can be found in a complex aquifer system in the study area, where the weathering of the metasedimentary and meta-volcanic rocks, in addition to the main fault zones mainly the extensional fractures where the water reservoir is structurally controlled 4. Hydyrogeophysical Methods As a consequence, both weathered layers and fracture zones play an important role for groundwater supply as porous layers and are considered hydraulic conductors. Moreover, fractures can easily found by low-expense geoelectrical and electromagnetic methods. Hence, two techniques were applied in this study to evaluate this complex aquifer system, the geoelectric and the electromagnetic methods are now routinely used as measuring anomalous quantities especially with parallel profiling arrays. Fig.2. Regional geological map of the Nuba Mountains region in Central Sudan. Fig.2. Mapa geológico regional das Montanhas Nuba na região central do Sudão. Geoelectric and VLF electromagnetic survey in Central Sudan Due to open water-filled fissures, the resistivity within a fracture zone is in general lower than the resistivity of the host rock even for dry fracture zones due to enhanced weathering at open fissures. 4.1. Geoelectric Survey Three geoelectric techniques were applied: horizontal electrical profiling (HEP) and vertical electrical sounding (VES), in addition to the electrical resistivity tomography (ERT). A number of 16 HEP were carried out using Terrameter SAS1000. A winner array was performed and laid out in a NE-SW orientation. A graphical plot of the apparent resistivity (ρa) versus AB/2 for each sounding was plotted simultaneously. The geoelectric data were compared to the VLF-R data qualitatively and quantitatively. More than 23 VES were carried out using Terrameter SAS1000. A shlumberger array was performed and laid out mainly in a NW-SE direction along prominent extensional fracture axis. A log-log plot of ρa versus AB/2 for each sounding was plotted simultaneously and inverted in IPI2Win software to calculate for the true resistivity values and their relative thicknesses. Fig.3 shows the inverted results of sounding TV19 and GrV11 as inversion examples, and the equivalence problem was considered during the processing of these VES data. HEP data were constrained by the nearest inverted VES locations. For comparative purposes, the ERT technique was chosen to provide some redundancy to the HEP and VES data and to improve the quality of the apparent resistivity responses. Based on hydrogeological considerations, 16 ERT profiles were initially measured using Wenner configuration crossing the NE-SW wadi flow. Each ERT profile was inverted smoothly. This inversion routine is a cell based inversion technique and subdivided the subsurface into a number of rectangular cells whose positions and sizes are fixed, which is used to determine the resistivity of cells that provides a model response that agrees with the observed data (Loke et al., 2003 and Günther, 2004). Fig.3. Examples of inverted soundings showing the different curve types in TV10 and GRV11, where the later illustrated the equivalence problem of the 1D inversion. Fig.3. Exemplos de sondagens invertidas mostrando os diferentes tipos de curvas em TV10 e GRV11, onde as últimas ilustram o problema de equivalência da inversão em 1D. 4.2. VLF-R Survey The very-low frequency-resistivity (VLF-R) is basically an electromagnetic method which detects electrical conductors by 97 utilizing radio signals in the 15 to 30 kHz range. VLF instruments compare the magnetic field of the primary (transmitted) signal to that of the secondary signal (induced current flow within the subsurface electrical conductor). When a conductor is crossed, the magnetic field becomes elliptically polarized and the major axis of the ellipse tilts with respect to the horizontal axis (McNeill & Labson, 1991). As with other frequency domain electromagnetic systems, both the in-phase (real or tilt-angle) and the out-of-phase (imaginary, ellipticity, or quadrature) components are measured. The VLF-R profiles were collected with Omni-plus system, manufactured by EDA Instruments Inc. (Now Scintrex Ltd.). The VLF-Resistivity (VLF-R) method was applied as a preliminary hydrogeological investigation of shallow structures in NE Nuba Mountains, using the transmitter stations GBZ, GBR and RHA as described in Table-1. The total magnitude of the earth's magnetic field and secondary field components of the primary field associated with these VLF stations were measured and stored every 10 meters. A total of 16 VLF-R profiles were carried out and thier responses at each station are presented separately where each profile is almost parallel to the regional strike of wadies with profile lengths vary from 300 to 1200 meters. Table 1. The used VLF transmitter stations GBZ, GBR and RHA of 16.0, 19.6 and 23.4 kHz. Tabela 1. As estações de transmissão VLF, GBZ, GBR e RHA usadas a 16.0, 19.6 e 23.4 kHz. 5. Integrated VLF and DC profiles It was observed that AlTrtr wadi changes its direction northeast wards instead of following the habitual direction of the extensional fractures as in the other three studied areas, which could be explained either by basement uplifting near VLF8 and DC4 or the release fracture deformation of the NE-SW strike may cause such effect. Both DCTP4 and VLFT8 profiles well mapped the southern edge fracture of the wadi, while DCTP1, VLFT9 and DCTP2 well mapped the northern edge fracture, with an estimated fracture width of ~600m (Fig.4). The VES data in DCTP1 and DCTP2 mapped the shallow basement at 8 to10m depth. Both VLF-R and DC profiles collected with 16.0 kHz in AlTrtr area showed shallow basement to the south which is confirmed by the VES data in DC4. In Albetira area, the drainage follows the NW-SE fractured quartzite of AlBetira fold. Khor (wadi) BanGadid and Baggara are well mapped and the high resistivity values in the middle of the wadies indicate the low lying basement as was observed in the field work. The interpretation of the VLF/HEP apparent resistivity readings is qualitative in nature; this was combined by VES data in which the current electrode spacings were gradually increased up to 600 m for the delineation of deeper structures, as shown in figures (4 and 5). Wadi Baggara was revealed in VLF3 with ~250m width while the corresponded DC1 was crossing a low line marble outcrop. DC3 and DC4 profiles delineate the fracture boundaries of wadi BanGadid while VLF2 mapped the effect of buried basement in shallow depths observed in the middle of the wadi as a high resistive dome anomaly. 98 N. E. Mohamed et al. / Comunicações Geológicas (2012) 99, 2, 95-100 fracture zones. The apparent resistivity data were inverted applying both smooth inversion and 2 layer-initial model robust inversions. The inverted models are shown in the form of contoured sections that help in visualizing the geological structures. Generally these models are geoelectrically subdivided into three zones: less than 20 ohm.m (clayey/clayey weathered products), ~120 ohm.m (coarse grained materials) and high resistive layer (hard rocks) up to 4000 ohm.m. Fig. 4. Combined VLF-R and HEP (DC) profiles across AlTrtr wadies. Ro and D are the calculated resistivity and depths to basement respectively from the adjacent VES locations. Shallow basement was recorded in DCT4 and VLF-T8 and explains the unordinary water flow toward the northeast direction. Fig. 4. Perfis combinados de VLF-R e HEP (DC) ao longo de AlTrtr wadies. Ro e D são a resistividade calculada e a profundidade à base respectivamente a partir das localizações de VES adjacentes. Base pouco profunda foi registada na DCT4 e VLF-T8 e explica o pouco usual fluxo de água para a direcção nordeste. Generally, the integrated VLF and HEP (DC) profiling combined with VES measurements was very efficient to map the fracture zones in hard rock terrains. Subsequently the location of these anomalous zones reveal that the fracture zones is AlTrtr area are wider and shallower while in AlBetira area are narrower and deeper especially that the VLF anomaly magnitude is larger in AlBetira. It is likely that fractures will become dry in summer season. However, fracture zones showing a large anomaly due to deeper conductive zones in AlBetira will be more suitable for groundwater exploitation for longer duration and it is unlikely that they will dry in summer season. The folded mountainous areas in AlBetira area represent a continuous recharging source in the hard rock areas, and as the movement of the groundwater takes place, the subsurface will become more productive due to an increase in the second porosity. 6. ERT and Laterally constrained 2D-VLF inversion For ERT data, a cell based inversion technique is commonly used; it subdivided the subsurface into a number of rectangular cells whose positions and sizes are mixed (Loke et al., 2003); to determine the resistivity of cells that provides a model response that agrees with the observed data. A commonly used inversion for 2D and 3D resistivity inversion is the regularized leastsquares optimization method (Oldenburg & Li, 1994). Based on the VES results and hydrogeological considerations, 16 imaging profiles were initially measured using wenner configuration and they crossed the NE-SW stream flow, which are prominent Fig. 5. Combined VLF-R and HEP (DC) profiles across BanGadid and Baggara wadies in AlBetira area. Ro and D are the calculated resistivity and depths to basement respectively from adjacent VES locations. The low lying basement was observed in the mid-wadi, which explains the anomalous high resistive values. Fig. 5. Perfis combinados de VLF-R e HEP (DC) ao longo de BanGadid e Baggara wadies na área de AlBetira. Ro e D são a resistividade calculada e a profundidade à base respectivamente a partir das localizações de VES adjacentes. A base pouco profunda foi observada no médio-wadi, o que explica os valores anómalos de alta resistividade. The 2Layinv program, made by Markku Pirttijärvi (2006), was used to interpret the electromagnetic VLF-R data (apparent resistivity and phase) along a single profile at a single frequency. The inversion is made separately for each data point using a onedimensional two-layer earth model which suits well the interpretation of the thickness and resistivity of layers and the resistivity variations of the basement rocks. Starting from an automatic initial model linearized inversion with adaptive damping was used to optimize the thickness and the resistivity of the overburden layer and the resistivity of the basement so that the model minimizes the error between the measured and the computed VLF-R data (less than 9%). As a result, a laterally constrained inversion and a smoothly varying model (Occam inversion) were obtained although it is actually one-dimensional model and that the interpretation results are shown as a 2-D resistivity pseudo section as shown in VLFT9 from AlTrtr area (Fig.6). More about smooth models from electromagnetic data Geoelectric and VLF electromagnetic survey in Central Sudan and Occam inversion are found in Constable & Parker (1987) and deGroot & Constable (1990). Fig. 6. Illustrates the VLF-R inversion routine as a 2D layer – laterally constrained model of VLF-T9 in ALTrtr area. 99 The inverted VLF data has data misfit less than 9% while the model misfit is less than 0.5%, this is a reasonable misfit range used for different geophysical inversion. VLF-Gr1 (from south to north) and VLF-Gr2 (from NE to SW) well mapped the southern fracture edge of AbuGeris wadi (Fig.7) though the abundance of the trees (Ketr trees) prevented further measurements towards the northeastern direction. In AbuGebiha area, the inverted VLF shows depths to basement, as in VLF-Gb2 and the corresponded ERT-Gb4. Also small resistive lenses are mapped at about 12m average depth (Fig.8). The inverted VLF-Gb1, across Tandik wadi, delineate the basement at ~12-37m depth while in ERT-Gb3 the basement was mapped at deeper depths in the southwestern part (~20m), nevertheless both VLF-Gb1 and ERT-Gb3 succeed to map the fracture zone in relatively same depths. Generally, the combined 2D laterally constrained VLF data and the ERT data revealed the depth to basement and located the fracture zones, Some VES measurements are needed in to improve hydro geophysical model of the fracture zones in this area especially 2km NW and SE from Alomda outcrop which is south of DC1 profile (Fig.8). Fig. 6. Ilustra a rotina de inversão VLF-R como uma camada 2D – modelo lateralmente constrangido da VLF-T9 na área ALTrtr. This inversion routine was used for all VLF-R profiles from the different four studied areas, nevertheless no DC profiles were prompted in AbuGeris and AbuGebiha areas, the 2D laterally constrained VLF inversion in both areas will be compared to the observed electric resistivity tomography (ERT) in these areas. The VLF apparent resistivity ranges from 30 to >1000 ohm.m, except of VLF Gb2 which crosses AlBatha wadi. Fig. 8. A combination of VLF and ERT profiles across AlBatha and Tandik wadis in AbuGebiha area, to detect the fracture zone. As shown, VLF-2 and ERT-4 do not reach the basement and a moderate resistive layer is observed in both profiles at ~20m depth. The fractured basement is mapped in both VLF-1 and ERT-3. Fig. 8. Uma combinação dos perfis VLF e ERTao longo de AlBatha e Tandik wadis na área de AbuGebiha para detectar uma zona de fractura. Tal como mostrado, VLF-2 e ERT-4 não chegam à base e é observada uma camada moderadamente resistiva em ambos os perfis aos ~20m de profundidade. A base fracturada está mapeada em ambos os VLF-1 e ERT-3. 6. Conclusions Fig. 7. A combination of VLF and ERT profiles across AbuGeris wadi, to detect the fracture zone and the basement is mapped as dashed lines with an average width of 200m. Fig. 7. Uma combinação dos perfis VLF e ERTao longo de AbuGeris wadi para detectar uma zona de fractura e a base está mapeada com linhas a tracejado com uma largura média de 200m. The VLF method is a very effective technique to locate zones of high electrical conductivity, such as mineralized or water-filled fractures or faults within the bedrock. Structures such as these often act as conduits along which ground water and contaminants flow. The combination of the VLF, VES and ERT data provide qualitative and quantitative information about the lateral and vertical variation of the basement surface and the fractured zones varying from tens to few hundred meters width as shown in 100 AlTrtr area. More data are needed to cover the gap areas of investigation in order to produce a reliable hydrogeological model. From the previous integrated geophysical measurements, the best aquifer targets for potential water supply in each area can be suggested as: the northern part of AlTrtr area and the wadi junction where it changes its direction to the northeast. In AlBetira area both Wadi Baggara and Wadi BanGadid are promising areas except that the water quality of BanGadid is better relatively than Baggara (Mohamed, et.al, 2011). In AbuGebiha the southern parts of the town and along Wadi AlBatha and Wadi Tandik of the town are considerably good aquifer targets. Acknowledgements Thanks and appreciations are due to: the German Academic Exchange Services (DAAD) for the financial support all over the period of this study. Appreciation goes to the Frie University – Berlin for providing the VLF equipment and to the field joined team from the Geological Research Authority in Sudan (GRAS) for providing the Resistivity Imaging equipment. Special gratefulness is due to Dr. Thomas Gunter for accessing his DC2DInvRes software. References Abdelsalam, M., Dawoud, A. S., 1991. The kabus ophiolitic melange, sudan, and its bearing on the western boundary of the nubian shield. Journal of the Geological Society, London, 148, 83-92. Browne, S. E., Fairhead, S. D., 1983. Gravity study of the central african rift system: A model for continental disruption, 1. the ngaoundere and abu gabra rifts. Tectonophysics, 94, 187-203. Constable, S., Parker, R., 1987. Occam' inversion: A practical alogrithm for generating smooth models from elctromagnetic data. Geophysics, 52, 289-300. N. E. Mohamed et al. / Comunicações Geológicas (2012) 99, 2, 95-100 deGroot Hedlin, C., Constable, S., 1990. Occam'inversion to generate smooth, two dimensional models from magnetotelluric data. Geophysics, 55, 1613-1624. Günther, T. 2004. Inversion methods and resolution analysis for the 2D/3D reconstruction of resistivity structures from DC measurements. Unpublished PhD Thesis, Univ. of Mining and Technology, Freiberg, Germany. Loke, M., Acworth, I., Dahkin, T., 2003. A comparison of the smooth and blocky inversion methods in 2d electrical imaging surveys. Exploration Geophysics, 34, 182-187. McNeill, J., Labson, V., 1991. Geological mapping using vlf radio fields electromagnetic methods in applied geophysics ii. In: Nabighian, M.N. (Ed.) Soc. Exp. Geophys., 521-640. Mohamed, N.E., Yaramanci, U., Kheiralla, K.M., Abdelgalil, M.Y., 2011. Assessment of integrated electrical resistivity data on complex aquifer structures in NE Nuba Mountains, Sudan. Journal of African Earth Sciences, 60, 337–345 Oldenburg, D., Li, Y., 1994. Inversion of induced polarization data. Geophysics, 59, 1327-1341. Pirttijärvi, M, 2006. 2Layinv program. A geophysical software for laterally constrained two-layer inversion of VLF-R measurements. Geophysics Division, Department of Geosciences, University of Oulu, Finland. Sadig, A., Vail, J. R., 1986. Geology and regional gravity traverses of the nuba mountains, kordofan province, Sudan. Journal of African Earth Sciences, 5, 329_338. Shaddad, M. S., Kropachev, S. M., Khalil, B., 1979. Regional geological setting of the nuba mountains in sudan. Annals geol. Surv of Egypt, IX, 446-454. Vail, J., 1973. Outline of the geology of the nuba mountains and vicinity, southern Kordofan province, Sudan. Bull. GMRD, Khartoum, 23, 24. Vail, J., 1983. Pan-african crustal accretion in northeast african. Journal of African Earth Sciences, 1, 285-294. Vail, J., 1985. Pan-african (late precambrian) tectonic terrains and reconstruction of the arabian nubian shield. Geology, 13, 839-842.