medical - Ionbond
Transcription
medical - Ionbond
MEDICAL T HE SURFAC E ENGINEERS™ We are the leader in Medical Coatings, you get the benefits Ionbond Coatings for Medical Implants… Ion Concentration (p.p.m.) Co Cr Mo 25 20 15 10 5 Low wear anti-allergy solutions There are two primary types of artificial joint designs, those that use polyethylene separators and those that employ metal-on-metal designs. In both cases Medthin™ coatings significantly improve the performance of these systems. 0 No coating TiN-TiN* CrN-CrN Corrosion Resistance Femoral head coated with Ionbond Medthin Ultrahigh Molecular Weight Polyethylene Tibial plate coated with Ionbond Medthin Wear (mm3) MOM TiN onTiN CrN on CrN 2.5 Prevents corrosion caused by contact with body fluids Minimizes the creation of polyethylene wear debris Reduction of the metallic ion concentration by a factor of 1000 x over uncoated implants Metal-on-Metal Designs In some systems metal-on-metal contact is the preferred solution. These ball-socket type of joints are common in hips, wrists, ankles, and fingers. Ionbond over the last 15 years has developed special coatings for these ball-socket systems. With the loads bearing directly on the metallic joints the wear resistance in such systems is of primary importance. Medthin™ coatings provide: Reduced wear by a factor of 10 over uncoated joints Low friction coefficients of less than 0.2 Consistently high film cohesion 2.0 1.5 1.0 Cycles (x106) 0.5 0.0 0.0 Polyethylene-based Designs The established design of articulating systems experiencing heavy loads, as for example in the case of a full knee replacement, is to use a polyethylene separator to avoid metal-on-metal (MOM) contact. Here Ionbond nanoscale coatings are essential in three ways: 0.5 1.0 1.5 2.0 Wear Resistance State of the art PVD, CVD, and PACVD coatings for Medical applications …in the Most Demanding Applications Tribology Ionbond‘s Tribological PVD/PACVD films Spinal discs can be coated with our industryleading Medthin™ 43 ADLC (Diamolith) that provides: Rough surface prepared for osseointegration Tribological solutions PVD/PACVD thin films Hydrophobic surfaces Higher contact angle when compared with other thin films such as PVD nitrides High hardness Low friction coefficient Approved for low load applications (< 300 N) Cell attachment © SmArtSpine SAS Poly-Ether-Ether-Ketone Poly-Ether-Ether-Ketone (PEEK) substrates coated with thick PVD Medthin™ 65 Ti for cell attachment (Hydrophilic surfaces – low contact angle): Ionbond recently developed a unique industrial scale technique for application of Medthin™ 65 Ti onto implants made of PEEK and Carbon Fiber re-inforced PEEK. Ionbond «Metal on PEEK» coating has the following properties: Adhesion > 20 MPa. Coating thickness up to 20µm. Coating possible on smooth plastic injected molded surfaces as well as on blasted surfaces Medthin™ 65 Ti is a coating suitable for cell attachment Cell attachment to Medthin™ 65 Ti Ionbond Coatings for Medical Instruments Anti-reflection Ionbond Nanocrystalline anti-reflection coatings for surgical instruments: Nanocrystalline coating structure of Medthin™ 20 coatings allow long life time through improved corrosion resistance Light reflection reduced by 70% Deposition temperature below 200 °C PVD-process preserves properties of thin instruments tips Ionbond has extended capacity for coating large volumes at our medical device coating locations worldwide. Thread coating Ionbond tailored coatings for screw and spindle systems: Reduction of Friction Reduction of Galling Color-coding Instruments made from stainless steel and CrCoMo can be color coded. Excellent chemical inertness Amorphous or dense nanostructured thin films High resistance to sterilization processes T HE SURFAC E ENGINEERS™ You make it first, we make it last The Medthin™ Family of Biocompatible Coatings Nanocrystalline-AlTiN Hardness [GPa] 1µm Columnar w/Nanograins 1µm Surface morphology 1µm 50µm Photo: Cross section micrograph Photo: Cross section micrograph Photo: Cross section micrograph Photo: morphology micrograph Medthin™ 43 ADLC Medthin™ 20 AlTiN Medthin™ 01; 16; 30; 60 TiN, TiAlN, CrN, ZrN, Medthin™ 65 Ti Adhesion [N]: >50 Friction Coefficient: 0.10 Color: Black Adhesion [N]: >70 Friction coefficent: 0.2 after post treatment Color: Dark Gray Physical properties Hardness [GPa] Elastic modulus [GPa] Adhesion [N]: >60 Thick films are possible Multilayers are possible Adhesion [MPa]: >20 Roughness Ra >1µm Excellent intrinsic roughness for cell attachment Applied on PEEK and CF-PEEK Elastic Modulus [GPa] Amorphous C:H 50 400 40 350 300 30 250 20 200 0 100 1.2 × 10 Wear rates Post-treated coatings As deposited coatings –5 Adhesion Adhesion [MPa] 150 Wear Rate [mm3/(Nm)] 10 25 1 × 10–5 20 8 × 10–6 6 × 10–6 15 4 × 10–6 10 2 × 10–6 1 × 10–7 5 For a complete list of coatings see www.ionbond.com Competence and Innovation – Worldwide Ionbond is a global leader in surface enhancement technology with 39 local coating centers and has been dedicated to the medical device industry for more than 20 years. Ionbond has pioneered the commercial application of hard coatings. The Ionbond Medthin™ line of Medical Grade Coatings meets the strict guidelines and performance requirements of the medical device industry. Quality and consistency are insured through compliance with established industry regulatory requirements that include certified biocompatibility according to ISO 10993-1 and compliance with the tenets of ISO 13485. Ionbond employs IQ, OQ, PQ process validated systems and Medthin™ coatings have US FDA Master Files for Medical Devices (MAF). Key locations for Medical Coatings NORTH AMERICA Ionbond US – Rockaway 200 Roundhill Drive US-Rockaway, NJ 07866 USA Phone: +1 973 586 4700 eMail: infous@ionbond.com EUROPE Ionbond Switzerland – Olten Industriestrasse 211 CH-4600 Olten Phone: +41 62 287 86 86 eMail: infoch@ionbond.com Ionbond France – Paris 19, rue Robert-Schuman F-77350 Le Mée-sur-Seine Phone: +33 1 64 83 01 25 eMail: infofr@ionbond.com Ionbond UK – Consett Unit 36 Number One Industrial Estate Medomsley Road Consett, County Durham GB DH8 6TS Phone: +44 1207 500 823 eMail: infouk@ionbond.com ASIA Ionbond China – Kunshan Plainvim International Kunshan Industrial Park Building M, No. 369 Yu Yang Road Kunshan City, Jiangsu Province CN-215300 Phone: +86 512 3687 5188 eMail: infocn@ionbond.com See our Website for a full list of our coating centers. www.ionbond.com T HE SURFAC E ENGINEERS™ 07.2016 Ionbond Malaysia – Kualalumpur No. 5 Block B, Jalan Sungai Kayu Ara 32/39 Taman Berjaya, Seksyen 32 MY-40460 Shah Alam, Selangor Phone: +60 16 661 2727 eMail: infomy@ionbond.com
Similar documents
forming and molding
Phone: +1 248 398 9100 Phone: +1 800 929 1794 eMail: infous@ionbond.com Ionbond US – Chicago 925 Atlantic Drive West Chicago, IL 60185 USA Phone: +1 630 231 9200 eMail: infous@ionbond.com
More information