Reznor V3-UESA Gas Fired Unit Heater
Transcription
Reznor V3-UESA Gas Fired Unit Heater
UESA HIGH EFFICIENT GAS-FIRED condensing UNIT HEATERS Cooke Industries - Phone: +64-9-579 2185 Fax: +64-9-579 2181 Email: sales@cookeindustries.co.nz Web: www.cookeindustries.co.nz REZNOR has over 35 years experience in designing and refining high efficient gas-fired unit heaters. The UESA is a condensing gas-fired unit heater and is designed for up to 104% heat input (Hi). The units are available in 4 different sizes, from 35 till 102 kW gas output. Simplicity and ease of use Up to 25 % lighter than the previous model and easy to install. The unit can be easily suspended from 4 suspen- sion points. All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection. The MacroChannel secondary heat exchanger has a Reliable and safe 3/4” PVC pipe for attaching a coupling, thus simplify- The UESA combustion circuit is separated from ing installation and cleaning of the required condensate drain. Thanks to the the vacuum combustion circuit the space to be heated. All connections (gas and electricity) are accessible the unit is extra safe and approved for all European countries. at one side of the heater. The internal security system protects the unit from overload and keeps the flue gas temperature down in the flue gas circuit. Main standard features The Tcore3TM high efficiency heat exchanger and single burner combustion system. The titanium stabilized aluminized steel primary heat exchanger with extruded aluminium MacroChannelSM secondary heat exchanger. The vibration and noise isolated fan motor. The sealed control compartment houses all electrical components. Cooke Industries - Phone: +64-9-579 2185 Fax: +64-9-579 2181 Email: sales@cookeindustries.co.nz Web: www.cookeindustries.co.nz Guaranteed high efficiency A conventional unit-heater does not use all available combustion heat. An important part of the heat is still present in the exhausted flue gases. The Reznor UESA is able to extract the residual heat by leading the flue gases through a second heat exchanger, so they cool down to a temperature below Side view: each compartment has its own door. the dewpoint. Design Environmentally friendly The unit heaters are designed to provide all the features Heating by gas is the most environmentally friendly you expect in a REZNOR heater plus improved heating method. efficiency, easier installation and a new look ~ both A condensing gas-fired unit heater has a higher heat inside and out. gain than for example a fuel oil condensing unit. Look for the unique white unit with no visible front and The flue gases extracted from natural gas contain less bottom hardware, deep red louvres and angled corner harmfull substances and the condensate is less to know you have a genuine REZNOR unit. corrosive. DIMENSIONS SIDE VIEW FRONT VIEW REAR VIEW 1. combustion air inlet 2. flue connection 3. gas connection 4. electrical connections 5. service panel 6. condensate drain Dimensions (mm) A B C D E F UESA 035-055 112 140 366 1512 510 456 UESA 083-102 99 225 470 1520 866 812 The dimensions are purely informative and are published with reservation. TOP VIEW Cooke Industries - Phone: +64-9-579 2185 Fax: +64-9-579 2181 Email: sales@cookeindustries.co.nz Web: www.cookeindustries.co.nz BALANCED FLUE WALL AND ROOF TERMINAL OR C-type: the allowed length between the unit heater and the flue terminal amounts to 9 m, a 90° bend offering an equivalent resistance of 1,5m and a 45° bend -0,75m. Advice: the high efficient balanced roof terminal avoids icicles. TECHNICAL DATA Model UESA 035 055 Gas category 083 102 II2H3+ (UK) Comb. air & flue, type B 1 B22p Comb. air & flue, type C C12, C32, C42, C52, C62, C82 1 Heat input Hs kW 37,74 58,60 88,01 107,66 Heat input Hi kW 34,00 52,80 79,30 97,00 Heat output kW 34,87 54,77 82,20 99,49 Thermal efficiency % 102,60 103,70 103,70 102,60 Gas consumption G20 m³/h 3,60 5,60 8,40 10,30 G25 m³/h 4,20 6,50 9,80 11,90 G31 kg/h 2,70 4,10 6,20 7,60 26 26 27 27 3900 6100 9060 10570 Gas pipe connection (not Ø supply line size) 3/4” Temperature rise ΔT ± 1 K Air flow (15°C) m³/h Nominal motor speed RPM 900 1400 900 900 Recommended mounting height 2 m 3,50 3,50 4 4 Horizontal throw m 25 40 34 36 dB (A) 67 75 74 73 4 dB(A) 45 53 52 51 Sound pressure 5 dB(A) 52 60 59 58 Total electrical rating 6 W 628 816 990 1300 Condensate amount l/h 2,30 3,10 6,60 7,50 Connection collars mm 100 100 130 130 Net weight kg 148 151 222 230 3 Sound power Sound pressure Electrical service (protection IP20) 230/240V 1N~50Hz 1. Gas Appliance Classifications for Approved Venting Methods based on CEN-report CR1749:2001 2. Height from floor to bottom surface of heater. These are recommendations only. Positioning of unit heaters for proper performance is application dependent. Operation is affected by other air moving equipment in the space, obstructions to the airflow, draughts and/or close proximity to doors or windows, etc… Care should taken to avoid mounting the heaters above these recom- mendations, unless downturn nozzle options are used, as significant stratification may occur resulting in poor floor coverage and higher energy losses through the roof structure. 3. Isothermal conditions at 20°C ambient air temperature, discharge louvre zero deflection, v = 0,5 m/s. 4. Sound pressure level in dB(A) in free field conditions, measured at 5 meters from the unit 5. Sound pressure level in dB(A), measured at 5 meters from the unit with A=160m² and Q=2 6. Measured at nominal input rate with G20 at 20°C ambient temperature. G A S T E C A T&B Group Company Cooke Industries - Phone: +64-9-579 2185 Fax: +64-9-579 2181 Email: sales@cookeindustries.co.nz Web: www.cookeindustries.co.nz 0805UESA GBEN J&M Sabbestraat 130 B-8930 Menen Belgium Tel. +32(0) 56 52 95 11 Fax. +32(0) 56 52 95 33 e-mail: reznor.europe@tnb.com website: www.reznor.eu Company Standards and Services: All Reznor products are tested and approved to CE standards. Reznor Europe nv is assessed to GASTEC EN ISO 9001: 2000 Quality Assurance. Reznor offers a service to its customers; including budget schemes, on site technical support and a comprehensive after-sales package. Reznor reserves the right to change specifications without prior notice.
Similar documents
Waste Oil Heaters MULTIPLE COST SAVINGS ENGINEERED FOR RELIABILITY (350 & 500 MBH)
More information
UNIT HEA TERS
»» Units can be selected to operate at 60 Hz or 50 Hz »» Accurate size selection can be determined by using Reznor selection software program ●●Dependable - The standard totally enclosed motors hav...
More informationLow NO High Efficiency Condensing Unit Heaters
Natural gas G20 Calorific value 10.48kW/m3 GCV, inlet gas pressure maximum 50mbar, minimum 17.5mbar. Propane G31 Calorific value 14.0kW/kg GCV, inlet gas pressure maximum 50mbar, minimum 37mbar.
More information