NEXIO NX1000MGX Hardware Guide for NX1000FCP
Transcription
NEXIO NX1000MGX Hardware Guide for NX1000FCP
Hardware Guide Nexio® NX1000MGX April 2014 175-000383-02 Delivering the Moment Publication Information © 2014 Imagine Communications Corp. Proprietary and Confidential. Imagine Communications considers this document and its contents to be proprietary and confidential. Except for making a reasonable number of copies for your own internal use, you may not reproduce this publication, or any part thereof, in any form, by any method, for any purpose, or in any language other than English without the written consent of Imagine Communications. All others uses are illegal. This publication is designed to assist in the use of the product as it exists on the date of publication of this manual, and may not reflect the product at the current time or an unknown time in the future. This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product. Trademarks 6800+™, ADC™, CCS Navigator™, Channel ONE™, ChannelView™, ClipSync™, Delay™, D-Series™, D-Series DSX™, Deliver the Moment™, Delivering the Moment™, FAME™, Farad™, G8™, G-Scribe™, HView™, IconMaster™, IconLogo™, IconStation™, IconKey™, InfoCaster™, InfoCaster Creator™, InfoCaster Manager™, InfoCaster Player™, InstantOnline™, Invenio®, Live-Update™, mCAPTURE™, Magellan™, Magellan CCS Navigator™, Magellan Q-SEE™, MultiService SDN™, NetPlus™, NetVX™, NewsForce™, Nexio® G8™, Nexio AMP® ChannelView™, Nexio® Channel ONE™, Nexio® ClipSync™, Nexio® Delay™, Nexio® Digital Turnaround Processor™, Nexio® Farad™, Nexio® GScribe™, Nexio® IconKey™, Nexio® IconLogo™, Nexio® IconMaster™, Nexio® IconStation™, Nexio® InfoCaster™, Nexio® InfoCaster Creator™, Nexio® InfoCaster Manager™, Nexio® InfoCaster Player™, Nexio® InfoCaster Traffic™, Nexio® InstantOnline™, Nexio® mCAPTURE™, Nexio® NewsForce™, Nexio® NXIQ™, Nexio® Playlist™, Nexio® Remote™, Nexio®RTX Net™, Nexio® TitleMotion™, Nexio® TitleOne™, Nexio® Velocity ESX™, Nexio® Velocity PRX™, Nexio® Velocity XNG™, Nexio® Volt™, OPTO+™, Panacea™, Platinum™, Playlist™, Predator II-GRF™, Predator II-GX™, Punctuate™, Remote™, RTX Net™, QuiC™, Q-SEE™, SD-STAR™, Selenio™, Selenio 6800+™, SelenioNext™, Selenio X50™, Selenio X85™, Selenio X100™, TitleMotion™, TitleOne™, Velocity ESX™, Velocity PRX™, Velocity XNG™, Versio™, Videotek® SD-STAR™, X50™, and X85™ are trademarks of Imagine Communications or its subsidiaries. Altitude Express®, Connectus®, Enabling PersonalizedTV®, ICE® Broadcast System, ICE Illustrate®, ICE-Q® algorithms, ICEPAC®, Imagine ICE®, Inscriber®, Inscriber® Connectus®, Invenio®, NEO®, Nexio®, Nexio AMP®, PersonalizedTV®, RouterWorks®, Videotek®, Videotek® ASI-STAR®, Videotek® GEN-STAR®, and Videotek® HDSTAR® are registered trademarks of Imagine Communications or its subsidiaries. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. HD-BNC is a trademark of Amphenol Corporation. Some products are manufactured under license from Dolby Laboratories. Dolby and the double-D symbol are registered trademarks of Dolby Laboratories. DTS Neural audio products are manufactured under license from DTS Licensing Limited. DTS and the Symbol are registered trademarks & the DTS Logos are trademarks of DTS, Inc. © 2008-2010 DTS, Inc. All other trademarks and trade names are the property of their respective companies. Contact Information Imagine Communications has office locations around the world. For locations and contact information see: http://www.imaginecommunications.com/contact-us/ Support Contact Information For support contact information see: Support Contacts: http://www.imaginecommunications.com/services/technical-support/ eCustomer Portal: http://support.imaginecommunications.com © 2014 Imagine Communications Corp. Proprietary and Confidential iii Contents About This Guide Intended Audience ........................................................................ 1 Finding Specific Information in This Guide ..................................... 2 Writing Conventions ............................................................................ 2 Related Documentation ....................................................................... 3 Obtaining Documentation .................................................................... 3 Unpacking/Shipping Information .......................................................... 5 Unpacking a Harris Product ........................................................... 5 Returning a Harris Product ............................................................. 5 Technical Support ................................................................................ 6 Chapter 1 Getting Started Overview ............................................................................................. 7 Starting the NX1000MGX .................................................................... 8 Confirming Connection to Additional Systems ..................................... 9 Chapter 2 Installation Rack Mounting .................................................................................. 11 Connecting the NX1000MGX ............................................................ 14 Rear Panel Port Descriptions ........................................................ 15 Front Panel Descriptions .............................................................. 17 Ethernet Teaming .............................................................................. 20 iv Contents Topologies ......................................................................................... 21 NX1000FCP ................................................................................. 21 NXA1000FTP ............................................................................... 23 NX1000MM ................................................................................ 25 NX1000IOL .................................................................................. 26 NX1000MIOH .............................................................................. 27 Chapter 3 Monitoring Status Monitoring Overview .......................................................................... 29 Front LED Indicator Lights ................................................................... 30 Ethernet Port Indicator Lights ............................................................. 32 Fibre Channel Card Indicator Lights .................................................... 33 Chapter 4 Troubleshooting The Power Supply Module .................................................................. 36 Identify and Replace Bad Power Supply Module ........................... 36 General PC Troubleshooting ............................................................... 37 IDE Hard Drive .................................................................................... 38 Index 1 About This Guide About This Guide provides an overview of this guide, describes guide conventions, and tells you where to look for specific information. This section also gives you important information on unpacking and shipping your Harris product. This guide introduces and describes procedures for installing and using the NEXIO™ NX1000MGX server. It also includes sample topologies for the NX1000FCP, NX1000FTP, NX1000MM, NX1000IOL, and NX1000MIOH. If the information in the release notes shipped with your product differs from the information in this guide, follow the instructions in the release notes. Intended Audience This guide is intended for users installing and operating the NEXIO Browse Encoder. 2 About This Guide Finding Specific Information in This Guide Writing Conventions This table shows the location of specific information in this guide. Table 1-1 Finding Specific Information in this Guide If you are looking for Go to Overview information about the NEXIO Browse Encoder Chapter 1: “Getting Started” on page 7 Installing and connecting the NEXIO Browse Encoder Chapter 2: “Installation” on page 11 Monitoring the status and health of the NEXIO Browse Encoder Chapter 3: “Monitoring Status” on page 29 Troubleshooting issues Chapter 4: “Troubleshooting” on page 35 This guide uses the following writing conventions. Table 1-2 Writing Conventions Convention Definition Bold Indicates dialog box, property sheet, field, button, check box, list box, combo box, menu, submenu, window, list, and selection names. Italics Indicates e-mail addresses, names of books and publications, and first instances of new terms and specialized words that need emphasis. CAPS Indicates a specific key on the keyboard, such as ENTER, TAB, CTRL, ALT, DELETE. Code Indicates variables or command-line entries, such as a DOS entry or something you type into a field. > Indicates the direction of navigation through a hierarchy of menus and windows. NEXIO NX1000MGX Hardware Guide Table 1-2 Writing Conventions Related Documentation Obtaining Documentation Convention Definition hyperlink Indicates a jump to another location within the electronic document or elsewhere. Internet address Indicates a jump to a Web site or URL. Note text Indicates important information that helps to avoid and troubleshoot problems. Caution text Indicates important information that if not followed could cause system problems. Warning text Indicates information that if not followed could prevent system operation or cause it damage. LLM User Guide (175-000163-03) NX1000MGX Installation Quick Start (175-000384-01) NEXIO Safety and Compliance Information Manual (175-000364-00) NEXIO FCP Integration Module User Guide (175-000509-01) NEXIO Ethernet Support Use of Customer Provided Ethernet Switches (MPR ABC-0001) Manuals, User Guides and other documents can be viewed or downloaded from the Harris Web site at https://premier.harris.com/ broadcast/. 1 Enter your E-mail and Password, and then click Submit. OR 3 4 About This Guide Click New User? to register with Harris. The Harris Broadcast Premier page appears. 2 Under NEXIO Server, click Support Documentation. 3 Click on the title of the desired document, and then click Open to view the document. OR Click Save to download the document. Tip: If you are having trouble finding a document, enter the title of the document or a keyword in the Keyword box, and then click search. Alternatively, contact your Harris Customer Service representative to request a document. NEXIO NX1000MGX Hardware Guide Unpacking/ Shipping Information Unpacking a Harris Product All Harris NEXIO products have been carefully inspected, tested and calibrated before shipment to ensure stable and trouble-free service. 1 Check the equipment for any visible damage that may have occurred during transit. 2 Confirm that you have received all items listed on the packing list. 3 Contact your Harris NEXIO dealer if any item on the packing list is missing. 4 Contact the carrier if any item is damaged. 5 Remove all packaging material from the product and its associated components before you install the unit. Returning a Harris Product In the unlikely event that a Harris product fails to operate properly, contact the Harris NEXIO Customer Service Department to obtain a Return Authorization (RA) number, then send the unit back for servicing. Include the RA number on the outside of the return box. Keep at least one set of original packaging in the event that a product needs to be returned for service. If the original package is not available, you can purchase replacement packaging from Harris Corporation. Otherwise, you can supply your own packaging as long as it meets the following criteria: The packaging must be able to withstand the product’s weight. The product must be held rigid within the package. There must be at least 2 in. (5 cm) of space between the product and the container. The corners of the product must be protected. If the product is still within the warranty period, Harris Corporation will return it to you by prepaid ground shipping after servicing. 5 6 About This Guide Technical Support Technical support is available 24 hours a day, 7 days a week. You can contact technical support by phone or e-mail. Phone: +1 888-534-8246 +1 416-445-4032 (International) +1 852-2174-2504 (Asia) E-mail: BCDService@harris.com Service.Europe@harris.com 7 1 Getting Started This chapter describes how to start and begin using the NEXIO™ Media Gateway Platform (NX1000MGX). This chapter includes the following topics: Overview Overview Starting the NX1000MGX Confirming Connection to Additional Systems The NEXIO Media Gateway Server, NX1000MGX, is a slim 1 rack unit server featuring mirrored boot drives, redundant hot swap power supplies, and redundant Fibre Channel connectivity to shared storage. NX1000MGX is designed to be a platform built for file transfer operations. An astonishing amount of connectivity is built into the machine. In addition to two 4Gb/s Fibre Channel connections, 6 Gigabit Ethernet ports are also provided. This gives the NX1000MGX unparalleled connectivity to the outside world as well as other NEXIO environments. It also provides 4 USB ports, for easy connection to a wide range of peripheral devices for added flexibility. FTP Server is provided as standard, making the NX1000MGX immediately ready for high speed data I/O. 8 Chapter 1 Getting Started Starting the NX1000MGX This section describes how to start the NX1000MGX and the initial tasks you should perform once you start the NX1000MGX server. To start the NX1000MGX Press the power button on the front panel. Under normal operation, the NEXIO server software starts when you start the server and the following application shortcuts appear on your desktop: LLM FTP Server After the Windows Start-up is complete you should see the following screen. Figure 1-1 NX1000MGX Main Screen NEXIO NX1000MGX Hardware Guide Table 1-1 Desktop Shortcuts Application Confirming Connection to Additional Systems Shortcut Description Low Level Module Starts the Low Level Module (LLM). The LLM application is the core software component for communication in your NEXIO system. FTP Server Starts the FTP Server and LLM. The FTP Server lets you manage the transfer of content in and out of your NEXIO system. Once the LLM has started confirm that the NX1000MGX is connected to shared storage and other NEXIO nodes. If the LLM does not start automatically, start if from the shortcut located on the desktop. If the LLM starts successfully, the LLM will see other nodes in the SAN indicating that the Ethernet network is functioning correctly and the SAN’s physical disk(s) indicating that the Fibre Channel network is operating correctly. If no active NEXIO nodes can be seen: Check to see if the light is on. Verify that the other nodes in the same SAN are operational. Check your Ethernet connections. Verify that the IP address is in the same range as other nodes on your NEXIO LAN. If the physical disk cannot be seen: Confirm that the NX1000MGX node can see the SAN’s drives using the Windows Device Manager. 9 10 Chapter 1 Getting Started If the drives cannot be seen in Windows Device Manager: Verify that the SAN storage system is operational. Check the Fibre Channel connections. Restart the NX1000MGX. If the SAN drives still cannot be seen: Contact Harris Customer Service for assistance. Figure 1-2 LLM Main Window The Local icon indicates the video server to which you are currently logged on. The Remote icons indicate all other active nodes. 11 2 Installation This chapter describes how to install and begin using the NEXIO™ NX1000MGX. This chapter includes: Rack Mounting Rack Mounting Connecting the NX1000MGX Ethernet Teaming Topologies The NX1000MGX comes with the following rack mounting hardware: Rack slides Rack extension brackets Note the following installation requirements/recommendations: Equipment — Mount the frame on an appropriate rack using the provided rack mounting and support equipment. Power source — Connect the power inlet to an adequate power source. Using a UPS is strongly recommended. Connect each of the two redundant power supply connections to a separate electrical circuit for added protection. 12 Chapter 2 Installation Adequate airflow — The NEXIO frames require adequate airflow around the chassis to provide sufficient cooling. All components draw air in through the front and exhaust via the rear of the frame. The surfaces must be clear of obstructions to provide proper air circulation and cooling. External device connections — Video monitors and all connections to external devices should be available and in working order. Cable clearance — Provide at least 2 inches of clearance in the rear of the rack for cabling. Insure that the rack is anchored to the floor so that it cannot tip over when the NX1000MGX is extended out of the rack. Refer to the NEXIO Safety and Compliance Information booklet for detailed safety and compliance information. To rack mount the NX1000MGX 1 Attach the rack rail to the chassis using (5) M10 screws on each side. Make sure the plastic retaining mechanism is located at the back of the chassis. Five of the holes on the inner rack rail line up with the holes on the chassis. 2 Attach the extenders to the outer rack rails to match the depth of your racks. 3 Attach the router rack rail to the rack mount rail post. 4 Slide the inner rack rail into the outer rack rail. 5 Attach the cables to the back panel of the chassis. 6 Turn on the chassis. 7 Use two thumbscrews to attach the bezel to the front of the chassis. NEXIO NX1000MGX Hardware Guide Figure 2-1 Rack Mounting To remove the chassis from the rack rail 1 Stand in front of the chassis and pull the rail out as far as it will go. 2 On the left rack rail, press down on the plastic retaining mechanism. 3 On the right rack rail, press up on the plastic retaining mechanism. For more information on rack mounting, see the NX1000MGX Installation Quick Start, part number 175-000384-00. 13 14 Chapter 2 Installation Connecting the NX1000MGX See the NX1000MGX rear panel connectors in Figure 2-2. The function of each connector is described in Table 2-1. Power Power Mouse Gigabit Ethernet Fibre Channel USB Keyboard Gigabit Ethernet RS-232 VGA Cable Figure 2-2 NX1000MGX Rear Panel Table 2-1 Rear Panel Connectors Label Description MOUSE Connector for PS2 mouse. KEYBOARD Connector for PS2 keyboard. GIGABIT ETHERNET RJ-45, 10/100/1000 Mbps baseband connection. USB Unassigned USB 2.0 port connector. VGA 15-pin port for primary VGA monitor connection. FIBRE CHANNEL 4Gb Fibre Channel connection to shared storage. NEXIO NX1000MGX Hardware Guide Rear Panel Port Descriptions The following sections describe the NX1000MGX rear panel port connections. Do not use wire or plastic ties on cables as this can impede cable performance. Use soft cable ties such as Velcro-based ties for wrapping cables. VGA The NX1000MGX has one VGA port. This lets you connect a monitor to the system. Ethernet There are six designated Gigabit Ethernet ports on the NX1000MGX. Harris servers that operate in a Storage Area Network (SAN) environment use Ethernet to keep all nodes in sync with each other and to perform functions not carried out via Fibre Channel. Port(s) assigned to this network are strictly for use by Harris products only. The Ethernet ports can be used for communications to the NEXIO LAN or file transfer. Ethernet port designations may change if you are in a teamed network environment. See “NX1000FCP” on page 21 for more information. NEXIO LAN—Designated as the LAN Ethernet port(s) for NEXIO systems control and communication. The following specifications apply to the NEXIO LAN: Use Ethernet network switch provided by Harris or customer provided switch as per MPR ABC-0001, NEXIO Ethernet Support Use of Customer Provided Ethernet Switches 100Base-T or 1000Base-T full duplex Ethernet (1000Base-T requires use of CAT5e or CAT6 cables) 100Base-T to the approved client workstations Category 5 or better cabling File Transfer—Lets you establish a transfer network to move content in and out of the NEXIO SAN via Ethernet. This is typically connected to a Gigabit Ethernet switch. These ports can be used by a 3rd party control system. 15 16 Chapter 2 Installation The following specifications apply when moving content in and out of a NX1000MGX: FTP Server must be running on the NEXIO node that is used to move clips in and out of the server system FTP Server does not need to run on the same NEXIO node that is using the FTP client controlling the transfer process All Ethernet link speed and duplex modes, including auto-detect, supported Category 5 or better cabling for up to 100Base-T networks Category 6 or better cabling for gigabit networks Clips can be transferred to and from any local drive, USB, shared folder, or mapped drive that is accessible by the NEXIO node’s transfer network port(s) or the Windows XP operating system FTP sites created for a drive, folder, or mapped drive that are accessed via Ethernet are created as folder type rather than an FTP server type For media transfers, the NEXIO FTP Server can move both SD and HD content in and out of the server system. USB There are four available USB 2.0 ports. Two USB ports are located on the front. Two USB ports are located on the rear of the NX1000MGX. All USB ports can be used to connect devices to the NX1000MGX. The following USB devices can be used as sources and destinations when moving content in and out of the NX1000MGX: USB CD-ROM/R/RW drives USB DVD-ROM/RW/RAM drives USB hard drives USB thumb drives An FTP site created for a USB device is created as folder type rather than an FTP server type. NEXIO NX1000MGX Hardware Guide These devices are mounted as drives by the Windows XP operating system. The mounted drives act as FTP sites when used in conjunction with FTP client software such as Transfer Manager. NEXIO supports USB 1.1 and 2.0. Keyboard/Mouse There is a port designated for use with a PS2 keyboard and a port designated for use with a PS2 mouse. Fibre Channel Fiber optical cable is used to connect the frame to shared storage. PORT 0 — Used for primary connection to storage. PORT 1 — Use only if directed by your system design. Front Panel Descriptions The front panel of the NX1000MGX includes the following: Alarm silence button DVD-ROM/CD-RW/Combo drive LED indicators Power on/off button Reset button USB ports Bezel illumination LED Redundant power supplies Figure 2-3 NX1000MGX Front Panel 17 18 Chapter 2 Installation Power (on/off) Button Alarm Silence Button Reset Button Bezel Illumination Switch Bezel Illumination LED Figure 2-4 Front Panel Buttons Power Button Use this button to turn on or turn off the NX1000MGX. Reset Button Use the Reset button to reset the NX1000MGX. Alarm Reset Button (only for the power supply) Use the Alarm Reset button to silence the alarm. An alarm sounds when only one power supply is connected or when there is a fault with one of the power supply connections. Possible Causes 1 The power source (strip) has failed. 2 The power cord is unconnected. 3 The power supply module has failed. See Chapter 4: “Troubleshooting” on page 35 for solutions. NEXIO NX1000MGX Hardware Guide Bezel Illumination Switch and LED The black microswitch senses when the bezel is removed and turns off the super-bright illumination LED to avoid inadvertently dazzling personnel. This switch defaults to the OFF state until it is pressed in by the front bezel or by your finger. The LED is illuminated as long as the switch is depressed. It is located below the bezel illumination LED. DVD/CD-RW Drive Use the DVD-ROM/CD-RW drive for DVD-ROM and CD-RW media. DVD-ROM/CD-RW drive USB ports Figure 2-5 DVD-ROM/CD-RW drive and USB ports LED Indicators The LED indicators show general status and health of the server. See “Front LED Indicator Lights” on page 30 for more information. Redundant Power Supplies The NX1000MGX comes with two redundant hot swappable power supplies located in the front of the machine. Under normal operation both modules work in tandem spreading the load between them. In the event of a failure, the functional module supplies all power needed by the machine. If a power supply module fails, an alarm will sound. Press the Alarm Reset button to silence the alarm. 19 20 Chapter 2 Installation To identify the failed power supply 1 Look at the status LED on the front of each module. The LED on the failed module will not be illuminated. 2 To remove a power supply, undo the thumb screw on the module and push the lock release tab to the left. 3 With the lock release tab still pushed to the left, grasp the module's handle and pull the module out of the frame. To insert a new power supply 1 Slide the replacement module into the empty slot. 2 Press firmly so that it clicks in place. If the power cord for the supply is in place, the module's status LED will illuminate. 3 Turn the thumb screw to secure the lock release tab. Ethernet Teaming Ethernet teaming is an industry standard method that lets you increase bandwidth when needed or create hardware redundancy in case one or more Ethernet interfaces fail. A team of Ethernet adapters functions as a single virtual network interface and does not appear any different to other network devices than a non-teamed adapter. A virtual network adapter advertises a single Layer 2 and one or more Layer 3 addresses. Ethernet Teaming is configured by Harris Field Support when the system is commissioned. Your Ethernet Teaming topology is based on the specifications outlined in your Sales Configuration order. Ethernet Teaming Requirements: An Extreme Networks (Summit 400 Series or BlackDiamond 8810) switch Ethernet switches must conform to IEEE 802.3ad (Link Aggregation) NEXIO NX1000MGX Hardware Guide Topologies NX1000FCP The following sections show sample topologies for connecting the NX1000FCP, NX1000FTP, NX1000MM, and NX1000IOL. The NX1000FCP enables you to connect up to 4 Macintosh clients using direct connect or by teaming up to 4 Ethernet ports. The following shows a sample NX1000FCP topology for directly connecting to MACs. Figure 2-6 Sample NX1000FCP Topology for Direct Connection to MACs 21 22 Chapter 2 Installation The following shows a sample NX1000FCP topology using teaming to connect to MACs. Figure 2-7 Sample NX1000FCP Topology for Teamed Connection to MACs NEXIO NX1000MGX Hardware Guide NXA1000FTP The NX1000FTP enables you to connect to FTP sources and destinations using a single connection, or by teaming up to 4 ports. The following shows a NX1000FTP topology using a single FTP connection. Figure 2-8 Sample NX1000FTP Topology for a Single FTP Connection 23 24 Chapter 2 Installation The following shows a NX1000FTP topology using a teamed FTP connection. Figure 2-9 Sample NX1000FTP Topology for Teamed FTP Connection NEXIO NX1000MGX Hardware Guide NX1000MM The NX1000MM enables you to connect as a Mirror Manager. The following shows a sample NX1000MM topology for Mirror Manager. Figure 2-10 Sample NX1000MM Topology for Mirror Manager 25 26 Chapter 2 Installation NX1000IOL The NX1000IOL enables you to connect to Preditor or a low resolution LAN. The following shows a sample NX1000IOL topology for connecting to Preditor or a low resolution LAN. Figure 2-11 Sample NX1000IOL Topology for Connection to Preditor or Low Resolution LAN NEXIO NX1000MGX Hardware Guide NX1000MIOH The NX1000MIOH is designed to support N + 1 MIOH servers streaming data from Fibre Channel shared storage over Ethernet to clients (I/O nodes) that are attached via Ethernet. This system design allows NEXIO to scale to very large channel counts, without being vulnerable to single points of failure in the connective layer. Groups of clients (I/O nodes) are not supported by single Ethernet to Fibre Channel bridge device. Instead, each client (I/O node) is able to automatically and seamlessly change to an alternate MIOH machine in the event there are communication problems with their primary MIOH. 27 28 Chapter 2 Installation 29 3 Monitoring Status This chapter describes how to monitor the status of the NEXIO™ NX1000MGX gateway server. This chapter contains the following sections: Monitoring Overview Monitoring Overview Front LED Indicator Lights Ethernet Port Indicator Lights Fibre Channel Card Indicator Lights The NX1000MGX displays general status information the following two ways: LED Indicator. DupliDisk RAID Management Utility The LED indicators are on the front and back panels of the NX1000MGX server. See Figure 3-12. The front LED indicator lights show general status and health of the NX1000MGX. 30 Chapter 3 Monitoring Status LED Indicators Figure 3-12 NX1000MGX Front Panel (without Bezel) Front LED Indicator Lights The general LED indicators are on the front of the NX1000MGX chassis. The Primary and Mirror LED indicators monitor status of the drives. The Status LED shows the status of the mirror between the master and slave drives. Figure 3-13 NX1000MGX Front Panel LED Indicator Lights Each NX1000MGX contains a set of mirror status LEDs that provide feedback, and a reset switch for the audible alarm (Buzzer). The following tables provide a description of the Control Panel display and functions. NEXIO NX1000MGX Hardware Guide Primary and Mirror LED’s monitor status of the drives as follows: Table 3-2 Primary and Mirror LED’s monitor status LED Description Solid Green Drive installed on the current channel. Flashing Orange Scanning the channel for drives Solid Red Drive not installed Flashing Red The Drive is marked as bad Orange Channel activity (read/write) Status LED’s show the status of the mirror between the master and slave drives as follows: Table 3-3 LEDs for the status of the mirror between the master and slave drives LED Description Solid Green Drives are in Mirror mode, data is identical. Flashing Green Drives may not be identical Solid Red Drives are not in Mirror mode* Flashing Red Copy/Compare is in progress Orange Copy/Compare in progress (under Windows) * Solid Red on Slave indicated that Slave drives are not present or not in mirror mode. The Buzzer provides the following indications: Short beep during power on (system boot up) indicates successful mirroring hardware self test. Second beep indicates the mirroring hardware is running in single mode. Continuous or intermittent beep indicates a drive failure. The Buzzer Off switch can be depressed to stop the beeping. 31 Chapter 3 Monitoring Status Left The NX1000MGX back panel has four Gigabit Ethernet ports with individual indicator lights. The NX1000MGX uses the Intel® PRO/1000 MT and PRO/1000 GT Quad Port Server Adapters for Ethernet connectivity. Left Right Right Figure 3-14 Gigabit Ethernet LED Indicators The right LED indicator lights represent link information. The left LED indicator lights represent connection speed information. Table 3-4 Gigabit Ethernet LED Descriptions Label LINK Ethernet Port Indicator Lights Right LED ACT/LNK CONNECTION SPEED 32 Left LED 10=OFF 100=GRN 1000=OR Indication Meaning Green on The port is connected to a valid link partner. Green flashing Data activity Off No link Orange flashing Identity Off 10 Mbps Green 100 Mbps Orange 1000 Mbps NEXIO NX1000MGX Hardware Guide Fibre Channel Card Indicator Lights The NX1000MGX uses the ATTO dual-channel Celerity FC-42XS host adapter to provide the highest available throughput for Fibre Channel applications. The Link LED indicators represent link connection information. If the Link LED is lit the storage adapter is online. The 4Gb and 2Gb LED indicators represent connection speed. Link Connection Speed Figure 3-15 Fibre Channel LED Indicators 33 34 Chapter 3 Monitoring Status 35 4 Troubleshooting This chapter describes workarounds or solutions for issues you may encounter when using the NEXIO™ NX1000MGX. This chapter includes information on the following topics: The Power Supply Module General PC Troubleshooting IDE Hard Drive 36 Chapter 4 Troubleshooting The Power Supply Module Identify and Replace Bad Power Supply Module Symptoms: The alarm is heard. What to do: 1 Look at the LEDs located on the power supply modules in the front of the NX1000MGX. The LED is located near the lock release tab and thumbscrew of each power supply module. The power supply module that does not have a powered LED light may be defective. A grey LED indicates that the power supply module is not powered on. Thumbscrew A green LED indicates that the power supply module is powered on. Release Tab Figure 4-16 Power Supply Modules 2 Ensure that both power cables are firmly inserted into the AC inlets in the rear of the NX1000MGX chassis. If seating the power cables turns off the alarm and the LED lights up on the module that was offline, the problem has been corrected. NEXIO NX1000MGX Hardware Guide 3 If the problem has not been corrected, do the following: a Loosen the thumbscrew. b Pull the power supply module out of the housing by squeezing the lock release tab in towards the power supply handle. c Gently pull on the power supply handle to remove the module. 4 Replace the power supply module with a known good module. 5 Reverse the procedure in step 3 to install the module into the chassis. If replacing the power supply module turns off the alarm and the LED lights up on the replaced module, the problem has been corrected. 6 If the problem has not been corrected, contact Harris Customer Service for further support. General PC Symptoms: Troubleshooting The computer has been turned on, but there is no VGA monitor output. What to do: 1 Check cable. Check the VGA cable to confirm that it is firmly attached. If the VGA cable was correctly seated, remove the VGA cable and check the VGA cable on known working device. 2 Verify power. Check to see that the chassis LED light up correctly. Check to see that both power supplies are turned on. Ensure that both power cables are securely inserted into the AC inlets in the rear of the NX1000MGX chassis and are plugged into a power outlet that is supplying the correct voltage. 3 If the problem has not been corrected, contact Harris Customer Service for further support. 37 38 Chapter 4 Troubleshooting IDE Hard Drive Symptoms: The front panel LED show that the Primary or Mirror drive is offline or that the RAID status is bad. What to do: Identify which drive is bad. See “Identifying a Bad Drive” on page 38. Replace the drive. See “Replacing the IDE Hard Drive” on page 41. Rebuild the drive. See “Rebuilding a Drive” on page 44. Identifying a Bad Drive You have two options to discover which drive is offline: To use the LED indicator lights, see the next procedure on this page. To use the GUI interface, see “Identifying a bad drive by using the DupliDisk3 Management Utility in the GUI” on page 39. Identifying a bad drive by using the LED indicator lights 1 Identify the bad drive by observing the LED on the front panel and noting the amber LED. See “Front LED Indicator Lights” on page 30 for a detailed description of what the LED lights signify. 2 Replace the IDE hard drive that is identified by the front panel LEDs as bad or not installed. Use the replacement instructions outlined “Replacing the IDE Hard Drive” on page 41. 3 If the problem persists, use the next procedure “Identifying a bad drive by using the DupliDisk3 Management Utility in the GUI” on page 39 to correct the problem, or contact Harris Customer Service for further support. NEXIO NX1000MGX Hardware Guide Identifying a bad drive by using the DupliDisk3 Management Utility in the GUI 1 Start the DupliDisk3 software from inside Windows by selecting Start > Programs > Arco DupliDisk. Figure 4-17 Navigating to DupliDisk3 The DupliDisk Raid Management Utility opens. 39 40 Chapter 4 Troubleshooting If there is a problem with a drive, it is marked as either Bad or Not Installed. The Primary channel is marked as Bad. The Mirror channel is marked as Not Installed. Figure 4-18 The DupliDisk Utility NEXIO NX1000MGX Hardware Guide Replacing the IDE Hard Drive 1 Disconnect all the cables from the chassis. 2 Remove the chassis from the rack. See the “To remove the chassis from the rack rail” on page 13. 3 Remove the lid of the chassis. a Remove the 3 screws from the top-front of the chassis. b Push the chassis lid back slightly, and then lift it straight up. 4 Disconnect the IDE hardware cable from the CD-ROM/IDE hard drive assembly. 5 Remove the screws that secure the CD-ROM/IDE hard drive assembly. 6 Remove the CD-ROM/IDE hard drive bracket assembly from the chassis. IDE Hardware Cable LED lights 41 42 Chapter 4 Troubleshooting 7 Remove the CD-ROM drive from the bracket. CD-ROM Primary Drive Mirror Drive LED lights 8 Remove the IDE hard drive/PC board assembly from the bracket and remove the IDE retaining screws of the drive to be replaced. NEXIO NX1000MGX Hardware Guide 9 Replace the IDE hard drive with NEXIO part number NX-DD-SD or equivalent Harris approved part and ensure proper alignment of the IDE pins to the PC board. 10 Re-assemble the NX1000 chassis by reversing the previous steps. 43 44 Chapter 4 Troubleshooting Rebuilding a Drive You can also use this process to check if a replaced drive is working properly. 1 Start the DupliDisk3 software from inside Windows by selecting Start > Programs > Arco DupliDisk. Figure 4-19 Navigating to DupliDisk3 The DupliDisk Raid Management Utility opens. Figure 4-20 DupliDisk Utility messages NEXIO NX1000MGX Hardware Guide 2 If the Scan Channels message displays, select YES to start the rebuild (copy) process. The DupliDisk Raid Management Utility window opens. Tip: If the Rebuild Drives message displays, click OK to start the rebuild process and go to step 3. If the next screen displays, the mirror drive is working properly. If there is a problem with it, one of the screens in Figure 4-18 displays instead. If this occurs, see step 4. This screen shows 2 healthy drives Figure 4-21 The Rebuild Tab 3 Click Start to begin the copy. Then click YES to confirm the rebuild. If the copy is successful, the following message displays: Figure 4-22 A successful rebuild 45 46 Chapter 4 Troubleshooting 4 If the rebuild was not completed successfully, you may decide to check the log file by selecting File > View Log. Figure 4-23 View Log Tip: If you know how to use the View Log, use it to troubleshoot the issue. If you do not know how to use it, call Customer Service and go over the View Log with the Customer Service representative. 5 If the RAID rebuild fails to complete or if the RAID rebuild is successful but the original problem resurfaces, contact Harris Customer Service for further support. 47 Index B I back panel 14 bezel illumination 19 installation rack mounting 12 requirements 11 intended audience 1 C connectors 14 customer support 6 D Drive Access LED 31 DupliDisk3 30 DVD/CD-RW drive 19 E L LED Ethernet 32 Fibre Channel 33 LED indicators 19, 29, 30 Drive Access 31 Fan Fail 31 LEDs 32 Ethernet 15, 32 N F NX1000FCP topology 21 NX1000FTP topology 23, 27 NX1000IOL topology 26 NX1000MM topology 25 Fan Fail 31 Fibre Channel 17 LEDs 33 finding information 2 front panel alarm reset 18 bezel illumination 19 DVD/CD-RW drive 19 LED indicators 19, 29, 30 power button 18 reset button 18 P ports Ethernet 15 keyboard 17 mouse 17 USB 16 power button 18 power supply module failure 36 48 Index replacing 37 R rack mounting 12 rear panel 14 Ethernet 15 Fibre Channel 17 keyboard 17 USB 16 VGA 15 related documentation 3 reset 18 topologies 21 topology NX1000FCP 21 NX1000IOL 26 NX1000MIOH 27 NX1000MM 25 NXA1000FTP 23 U USB 16 V S VGA 15 solutions 35 support 6 W T technical support 6 workarounds 35 writing conventions 2