Architectural Inspection Asset Data
Transcription
Architectural Inspection Asset Data
NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 P.S. 26 - BROOKLYN, 1014 LAFAYETTE AVENUE, BROOKLYN, NY, 11221 School: InspectionId Inspection Type 303 ARCHITECTURAL - SENIOR 322 ARCHITECTURAL - ASSOCIATE Time In Last Edited 2014-10-16 09:16AM 2014-10-16 07:36AM 2015-05-29 01:37PM 2015-03-04 08:15AM Asset Data Question Answer Was the Building Fully Accessible for Inspection? Principal(s) Information Principal Name Principal Organization Meeting with Principal? Principal Feedback Yes Cynthia Celestine P.S. 26 - Brooklyn No The Principal's comments are as follows: 1-Electrical outlets to accommodate existing A/C units need to be installed. (The Fireman noted that there are brand new A/C units for various Classrooms unused because of no outlets to plug in to.) 2-Electrical outlets need to be upgraded. Principal Name Principal Organization Meeting with Principal? Principal Feedback Elvin Crespo Frederick Douglas Academy IV No No Feedback from Principal Principal Name Principal Organization Meeting with Principal? Principal Feedback Sharon Stephens Madiba Prep No No Feedback from Principal Wolfgang Hellmann Michael Wilson 124,000 None 3+B 1956 561 90 51 Fair Custodian Fireman Building Square Footage Comments on the Area (Square Feet) Comments on the Stories (Floors) plus Basements Comments on the Year Built Comments on the Student Population Comments on the Staff Population Comments on the Number of Classrooms Weather Facade Photo From Malcolm X & Lafayette Facing SW Mobile Validity Version 2.0 (P) Page 1 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Main Entrance Photo Malcolm X Blvd. Entry Roof Photo Atop 1965 Addition facing Northeast Systems: Roof replacement, New Coping, Flashing, Roof Barrier, Roof Fence and Drains. Exterior Masonry, Parapets, Bulkheads repaired. Years: 2013 Systems: Limited Roof and Drain repairs. Have any Systems/Major Building Components been upgraded? Years: Systems: 2010 New Science Labs. Years: Systems: 2009 Windows replaced, limited exterior masonry repairs, Parapet repairs. 2007 Roofs replaced. Years: Systems: Have there been any New Building Additions? Tandem Years: 1998 1965 + 18600 No Tandem Leased Space? No Priority Condition Priority Condition Exist Last Year? Priority Category Mobile Validity Version 2.0 (P) Condition Description Component Affected Location Description Page 2 of 33 Person(s) Notified Person(s) Title PhotoImage Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection No Broken Glass K026 Classroom window is cracked. Windows Room 347 Michael Wilson Fireman Structural Engineer Required Structural Condition Type Condition Description Component Affected Location Description Person(s) Notified Person(s) Title PhotoImage No condition recorded Accessibility Accessibility Status Question Response Is the Primary or secondary entrance on an accessible route? Is the building a multi-story building? Are All floors of the building accessible through compliant means? Are SOME floors other than the 1st floor and basement accessible through compliant means? Do any of the following spaces exist on the First floor? Classroom, Art Room, Auditorium, Cafeteria, Computer, Gymnasiums, Library, Multipurpose Room, Science Labs For the rooms that do exist, are SOME of them accessible on the 1st floor? Boys and Girls or Unisex accessible toilets exist on the 1st floor? Yes Yes No No Physical Breakdown Structure Exists Complies Yes Yes No Required Deficiency FUNCTIONAL ACCESSIBILITY Exterior Routes Yes Exterior Entrances & Exits Exterior H/C Lifts No No Exterior Ramps and Railings Yes Yes Yes Yes Interior Routes Interior Corridor Doors And Hardware Yes Interior Corridors & Lobbies Interior Elevators No Interior H/C Lifts No Yes Yes Interior Lobby Doors And Hardware No Interior Ramps Rooms & Spaces Art Rooms Room 104 Yes No NOT ON ACCESSIBLE ROUTE Auditorium 1st Floor Yes Yes 1st Floor Yes Yes None on Accessible Route Yes No Cafeteria Classrooms NOT ON ACCESSIBLE ROUTE Computer Rooms Rooms 205 & 308 Yes No NOT ON ACCESSIBLE ROUTE Gymnasium Mobile Validity Version 2.0 (P) Page 3 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection Physical Breakdown Structure K026 Exists Complies 1st Floor Yes Yes Room 231 Yes No Required Deficiency Library NOT ON ACCESSIBLE ROUTE Main Office Rooms 113, 212, 312 Yes No NOT ON ACCESSIBLE ROUTE Multi-purpose Room No Nurse's Office Room 109 Yes No NOT ON ACCESSIBLE ROUTE No Pool Science Lab Rooms 234, 236 Yes No NOT ON ACCESSIBLE ROUTE Toilet Rooms (boys) At Cafeteria Yes No CLEAR OPENING < 32" SINK ARRANGEMENT TURNING RADIUS URINAL ARRANGEMENT WATER CLOSET ARRANGEMENT Toilet Rooms (girls) At Cafeteria Yes No CLEAR OPENING < 32" SINK ARRANGEMENT TURNING RADIUS WATER CLOSET ARRANGEMENT Toilet Rooms (staff) Auditorium/Gymnasium Lobby Yes No CLEAR OPENING < 32" SINK ARRANGEMENT TURNING RADIUS URINAL ARRANGEMENT WATER CLOSET ARRANGEMENT Mobile Validity Version 2.0 (P) Page 4 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Building Template Inspection Question Response Architectural ATHLETIC FIELDS Does not exist EXTERIOR Inspected Inspected AREAWAY Instance AW1-AW4 4- Between Fair and Poor Instance Condition Instance Quantity 4 EACH Instance Quantity Uom Deficiency Deficiency Location/Instance AREAWAY GRATINGS:MINOR RUSTING Deficiency Quantity 120 S.F. MAINTENANCE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 AW4 Violations No violations recorded Deficiency Mobile Validity Version 2.0 (P) AREAWAY DRAINS:CLOGGED Page 5 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response EXTERIOR AREAWAY Deficiency Location/Instance Deficiency Quantity 1 EACH MAINTENANCE PRIORITY 5 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected AWNINGS AND CANOPIES 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected CHIMNEY Material Type(s) Masonry 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected COPING 1- Good Condition Deficiency No deficiencies recorded CORNICE Does not exist DOORS Inspected Inspected DOOR HARDWARE Condition 3- Fair Inspected DOORS AND FRAMES Condition 4- Between Fair and Poor Deficiency METAL CLAD:DETERIORATED DOOR AND FRAME MAJOR DETERIORATION Deficiency Location/Instance Deficiency Quantity 10 EACH REPLACE PRIORITY 4 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Cafeteria Exit, Facade B Violations No violations recorded Deficiency Mobile Validity Version 2.0 (P) METAL CLAD:DETERIORATED DOOR AND FRAME MINOR DETERIORATION Page 6 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response EXTERIOR DOORS DOORS AND FRAMES Deficiency Location/Instance Deficiency Quantity 4 EACH MAINTENANCE PRIORITY 4 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Facade B Exit Doors Violations No violations recorded Inspected LINTELS Condition 2- Between Good and Fair Deficiency No deficiencies recorded Does not exist TRANSOM/SIDE LIGHT EXTERIOR SOFFITS Does not exist EXTERIOR WALLS Material Type(s) Inspected Masonry Replacement Quantity Replacement Uom 36,000 S.F. Instance on All Facades Inspected Instance Condition 2- Between Good and Fair Instance Quantity Instance Quantity Uom 36,000 SF Deficiency CAST IN PLACE / PRE-CAST CONCRETE:MAJOR CRACKS/SPALLING Roof Plan Reference Elevation Elevation Reference Deficiency Quantity Facade A 20 S.F. REPLACE Quantity Uom Potential Action Mobile Validity Version 2.0 (P) Page 7 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response EXTERIOR EXTERIOR WALLS Urgency of Action Purpose of Action Deficiency Photo 1 PRIORITY 4 LEVEL 2 Facade A Violations No violations recorded LOADING DOCK Does not exist LOUVER Inspected 2- Between Good and Fair Condition Deficiency Roof Plan Reference MISSING SCREEN Elevation Deficiency Quantity 5 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Facade F Violations No violations recorded Inspected PARAPETS Material Type(s) Masonry Replacement Quantity Replacement Uom 9,000 C.F. Instance on All Facades Inspected Instance Condition 2- Between Good and Fair Instance Quantity Instance Quantity Uom 9,000 CF Deficiency No deficiencies recorded Does not exist PLAZA DECK Mobile Validity Version 2.0 (P) Page 8 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response EXTERIOR Inspected ROOF Inspected Roofing Replacement Quantity Replacement Uom 55,000 S.F. LEADERS, GUTTERS, DOWNSPOUTS, SCUPPERS Inspected 1- Good Condition Deficiency No deficiencies recorded Inspected ROOF BARRIER 1- Good Condition Deficiency No deficiencies recorded ROOF CAGE Does not exist ROOF FENCE Inspected 1- Good Condition Deficiency No deficiencies recorded Inspected ROOF HATCH/SMOKE HATCH 1- Good Condition Deficiency No deficiencies recorded Inspected ROOFING Instance on Modified Bitumen:All Roofs Inspected Instance Condition 1- Good Instance Quantity Instance Quantity Uom "Does the roof have major mechanical equipment?' Installation Year Source of Installation Year 55,000 S.F. No 2013 Custodial staff Deficiency No deficiencies recorded Inspected ROOFING DRAINS 1- Good Condition Deficiency No deficiencies recorded Inspected Specialties Inspected BULKHEAD/PENTHOUSE 2- Between Good and Fair Condition Deficiency No deficiencies recorded CUPOLA/ SPIRES/ TOWERS Does not exist DORMER Does not exist DUNNAGE STEEL Does not exist ROOF/GRAVITY TANK Does not exist SKYLIGHT/ROOF VENT Does not exist Inspected STAIRS/RAMPS: EXTERIOR Inspected BUILDING CHEEK/FLANK WALLS Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected RAILINGS Condition 4- Between Fair and Poor Deficiency Deficiency Location/Instance MISSING RAILING Deficiency Quantity 20 L.F. REPLACE Quantity Uom Potential Action Mobile Validity Version 2.0 (P) Page 9 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response EXTERIOR STAIRS/RAMPS: EXTERIOR RAILINGS Urgency of Action Purpose of Action Deficiency Photo 1 PRIORITY 5 LEVEL 6 Facade G Exit Violations No violations recorded Inspected STAIRS/RAMPS Condition 2- Between Good and Fair Deficiency Deficiency Location/Instance STONE:WORN-OUT TREAD/RISER/NOSING Deficiency Quantity 10 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Facade B Violations No violations recorded Inspected WINDOWS Replacement Quantity Replacement Uom 15,000 SF EXTERIOR GUARDS Inspected Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected LINTELS Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected WINDOWS Material Type(s) Instance on Aluminum:All Facades Aluminum Inspected Instance Condition 2- Between Good and Fair Instance Quantity Instance Quantity Uom Installation Year 15,000 SF 2007 Mobile Validity Version 2.0 (P) Page 10 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response EXTERIOR WINDOWS WINDOWS Source of Installation Year Custodial staff Deficiency Roof Plan Reference ALUMINUM:BROKEN PANE Elevation Elevation Reference Deficiency Quantity Facade B 6 S.F. MAINTENANCE PRIORITY 5 LEVEL 6 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Room 347 Violations No violations recorded Deficiency Roof Plan Reference ALUMINUM:HARDWARE POOR CONDITION/MISSING Elevation Elevation Reference Deficiency Quantity All Facades 12 EACH MAINTENANCE PRIORITY 4 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected INTERIOR Mobile Validity Version 2.0 (P) Page 11 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR AUDITORIUM Inspected Instance on 1st Floor - 396 Seats Ceiling Instance on 1st Floor - 396 Seats Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Door(s) Instance on 1st Floor - 396 Seats Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Fixed H/C Lift Does not exist Instance on 1st Floor - 396 Seats Fixed Seating Instance on 1st Floor - 396 Seats Inspected Instance Condition 2- Between Good and Fair Deficiency Deficiency Location/Instance Deficiency Quantity DAMAGED/BROKEN/INOPERABLE Seats H/8, M/1, Q/101, R/6, S/1 and others 10 EACH REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Seat H/8 Violations No violations recorded Floor Finish Instance on 1st Floor - 396 Seats Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Sliding-folding Partition Instance on 1st Floor - 396 Seats Does not exist Instance on 1st Floor - 396 Seats Inspected Stage Stage Instance on 1st Floor - 396 Seats Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Stage Curtain Rigging Instance on 1st Floor - 396 Seats Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Stage Curtains Instance on 1st Floor - 396 Seats Inspected Instance Condition 3- Fair Deficiency Deficiency Location/Instance Deficiency Quantity WORN/DETERIORATED Front, rear curtains 200 Mobile Validity Version 2.0 (P) Page 12 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR AUDITORIUM Stage Stage Curtains Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 S.F. REPLACE PRIORITY 3 LEVEL 2 Front curtain Violations No violations recorded Walls Instance on 1st Floor - 396 Seats Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Window Curtains/Shades/Blinds Instance on 1st Floor - 396 Seats Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded CAFETERIA Inspected Instance on 1st Floor Ceiling Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Door(s) Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Fixed Equipment Does not exist Instance on 1st Floor Floor Finish Instance on 1st Floor Inspected Instance Condition 5- Poor Deficiency Deficiency Location/Instance VINYL TILES:DETERIORATED SUBSTRATE Center of Cafeteria, near kitchen, near toilet rooms and other locations 1,000 S.F. REPLACE PRIORITY 3 LEVEL 2 Deficiency Quantity Quantity Uom Potential Action Urgency of Action Purpose of Action Mobile Validity Version 2.0 (P) Page 13 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR CAFETERIA Floor Finish Deficiency Photo 1 Center of Cafeteria Violations No violations recorded Sliding-folding Partition Instance on 1st Floor Does not exist Instance on 1st Floor Does not exist Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Stage Walls Window Curtains/Shades/Blinds Does not exist Instance on 1st Floor Inspected CLASSROOMS/CORRIDORS/ADMIN SPACES Inspected Ceiling Condition 2- Between Good and Fair Deficiency Deficiency Location/Instance ACOUSTIC TILES ON PLASTER:DAMAGED/MISSING Rooms 113, 341, Corridor near Rooms 103, 206, 211, 313 and other locations 50 S.F. REPLACE PRIORITY 3 LEVEL 2 No violations recorded Deficiency Quantity Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected Door(s) Condition 5- Poor Deficiency Deficiency Location/Instance Deficiency Quantity WOOD:DETERIORATED DOOR Rooms 135, 145, 232, 242A, 304 and other locations 10 EACH MAINTENANCE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Room 304 Violations No violations recorded Inspected Floor Finish Condition Mobile Validity Version 2.0 (P) 2- Between Good and Fair Page 14 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR CLASSROOMS/CORRIDORS/ADMIN SPACES Floor Finish Deficiency Deficiency Location/Instance Deficiency Quantity TERRAZZO:CRACKS North lobby 100 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 North lobby near Cafeteria Violations No violations recorded Deficiency Deficiency Location/Instance VINYL TILES:BROKEN/DETERIORATED/MISSING TILES Rooms 101, 208, 348, Corridor near Rooms 132, 226, 357 and other locations 200 S.F. REPLACE PRIORITY 3 LEVEL 2 Deficiency Quantity Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Room 208 Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity EPOXY FLOORING:CRACKS/SPALLING Room 236 50 S.F. REPLACE PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected Specialties Inspected Classroom Locker(s) 2- Between Good and Fair Condition Deficiency No deficiencies recorded Does not exist Fixed Seating Inspected Walls Condition 2- Between Good and Fair Deficiency Deficiency Location/Instance GLAZED BLOCK:CRACKS/SPALLING Corridor near Room 115, 249, 247, 346, opposite Room 357 and other locations 50 Deficiency Quantity Mobile Validity Version 2.0 (P) Page 15 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR CLASSROOMS/CORRIDORS/ADMIN SPACES Walls Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 S.F. REPLACE PRIORITY 3 LEVEL 2 Corridor opposite Room 357 Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity STONE:CRACKS/SPALLING North lobby 20 S.F. REPLACE PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations GYMNASIUM Inspected Instance on 1st Floor Ceiling Does not exist Instance on 1st Floor Door(s) Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Fixed Equipment Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Floor Finish Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency Deficiency Location/Instance Deficiency Quantity WOOD:DAMAGED/DETERIORATED Near drinking fountain 10 S.F. REPLACE PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Seating Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Sliding-folding Partition Instance on 1st Floor Does not exist Instance on 1st Floor Does not exist Stage Mobile Validity Version 2.0 (P) Page 16 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR GYMNASIUM Walls Instance on 1st Floor Inspected Instance Condition 3- Fair Deficiency Deficiency Location/Instance Deficiency Quantity WALL PADDING:DETERIORATED North, east and west sides of Gymnasium 140 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Northeast corner Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity MASONRY:CRACKS/SPALLING North, south and west sides of the Gymnasium 200 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 North side of the Gymnasium Violations No violations recorded Window Curtains/Shades/Blinds Does not exist Instance on 1st Floor Inspected INTERIOR DOOR HARDWARE 2- Between Good and Fair Condition Inspected INTERIOR GUARDS 2- Between Good and Fair Condition Deficiency No deficiencies recorded KITCHEN/WARMING PANTRY Inspected Instance on 1st Floor Ceiling Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Door(s) Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Mobile Validity Version 2.0 (P) Page 17 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR KITCHEN/WARMING PANTRY Floor Finish Instance on 1st Floor Inspected Instance Condition 3- Fair Deficiency Deficiency Location/Instance Deficiency Quantity CERAMIC TILE:BROKEN/MISSING TILES Near freezers, rear exit, corridor to rear exit and other locations 40 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Near freezers Violations No violations recorded Walls Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency Deficiency Location/Instance CERAMIC TILE:BROKEN/ MISSING Near entrance on right side of serving area, left side of kitchen near freezers and other locations 20 S.F. REPLACE PRIORITY 3 LEVEL 2 No violations recorded Deficiency Quantity Quantity Uom Potential Action Urgency of Action Purpose of Action Violations LIBRARY Inspected Instance on Room 231 Built-in Furnishing Instance on Room 231 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Ceiling Instance on Room 231 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Door(s) Instance on Room 231 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Floor Finish Instance on Room 231 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Room 231 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Walls Mobile Validity Version 2.0 (P) Page 18 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR LOCKER ROOM Instance on Basement - Boys Inspected Alternative Use Yes Instance on Basement - Girls Inspected Alternative Use Yes Ceiling Instance on Basement - Boys Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Basement - Girls Inspected Instance Condition 2- Between Good and Fair Deficiency Deficiency Location/Instance Deficiency Quantity PLASTER:CRACKS/SPALLING Near locker room entrance, near shower room 20 S.F. REPLACE PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Door(s) Instance on Basement - Boys Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Basement - Girls Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Floor Finish Instance on Basement - Boys Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Basement - Girls Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Locker Room Lockers Instance on Basement - Boys Inspected Instance Condition 3- Fair Deficiency No deficiencies recorded Instance on Basement - Girls Does not exist Instance on Basement - Boys Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Basement - Girls Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Walls MULTI-PURPOSE ROOM Does not exist POOLS Does not exist SCIENCE DEMO ROOM Does not exist SCIENCE LAB Instance on Rooms 234, 236 Inspected Alternative Use No Fixed Equipment Instance on Rooms 234, 236 Inspected Instance Condition 1- Good Mobile Validity Version 2.0 (P) Page 19 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR SCIENCE LAB Fixed Equipment Deficiency No deficiencies recorded SCIENCE PREP ROOM Instance on Room 235 Inspected Alternative Use No Fixed Equipment Instance on Room 235 Inspected Instance Condition 1- Good Deficiency No deficiencies recorded SHOWER ROOM Instance on Basement - Boys Inspected Alternative Use Yes Instance on Basement - Girls Inspected Alternative Use Yes Ceiling Instance on Basement - Boys Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Basement - Girls Inspected Instance Condition 5- Poor Deficiency Deficiency Location/Instance Deficiency Quantity PLASTER:CRACKS/SPALLING Center and right side of the room 200 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Center and right side of the room Violations No violations recorded Door(s) Instance on Basement - Boys Does not exist Instance on Basement - Girls Does not exist Floor Finish Instance on Basement - Boys Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Basement - Girls Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Basement - Boys Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Basement - Girls Inspected Instance Condition 5- Poor Walls Mobile Validity Version 2.0 (P) Page 20 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR SHOWER ROOM Walls Deficiency Deficiency Location/Instance Deficiency Quantity GLAZED BLOCK:CRACKS/SPALLING Rear of the room 120 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Rear of the room Violations No violations recorded Inspected STAIRS/RAMPS: INTERIOR Do Letter Stair Signs Exist? Yes Inspected Ceiling Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Door(s) Condition 2- Between Good and Fair Deficiency No deficiencies recorded Partition Does not exist Railings Inspected Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Stairs and Landings Condition 2- Between Good and Fair Deficiency Deficiency Location/Instance Deficiency Quantity STONE:BROKEN/MISSING Stair D/Basement, exit vestibule on west side of Cafeteria 30 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Exit vestibule on west side of Cafeteria Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity VINYL TILES:BROKEN/DETERIORATED/MISSING TILES Stair A/1, 2, 3 60 S.F. REPLACE Quantity Uom Potential Action Mobile Validity Version 2.0 (P) Page 21 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR STAIRS/RAMPS: INTERIOR Stairs and Landings Urgency of Action Purpose of Action Violations PRIORITY 3 LEVEL 2 No violations recorded Inspected Walls Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected STRUCTURAL Inspected COLUMNS/BEAMS/BEARING WALLS Condition 2- Between Good and Fair CONCRETE COLUMNS/BEAMS:CRACKED/SPALLED/REINFORCEMEN T EXPOSED West Corner of Crawlspace under Gymnasium 20 S.F. REPAIR PRIORITY 3 LEVEL 5 Deficiency Deficiency Location/Instance Deficiency Quantity Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 West Corner of Crawlspace under Gymnasium, also Basement under Auditorium near bell No violations recorded Violations Inspected FLOOR STRUCTURE Condition 4- Between Fair and Poor Deficiency CONCRETE:CRACKS/SPALLED/REINFORCEMENT EXPOSED Crawlspace under Gymnasium 150 S.F. REPAIR PRIORITY 3 LEVEL 5 Deficiency Location/Instance Deficiency Quantity Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Crawlspace under Gymnasium near Column 32. Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity CONCRETE SLAB ON GRADE:THRU CRACKS Basement under Auditorium Stage 200 S.F. REPAIR Quantity Uom Potential Action Mobile Validity Version 2.0 (P) Page 22 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR STRUCTURAL FLOOR STRUCTURE Urgency of Action Purpose of Action Deficiency Photo 1 PRIORITY 3 LEVEL 5 Basement under Auditorium Stage, also in Basement Boys And Girls Locker Rooms. No violations recorded Violations Inspected FOUNDATION WALLS Material Type(s) Concrete Condition 2- Between Good and Fair Deficiency CONCRETE:WATER INFILTRATION INTO NONINSTRUCTIONAL SPACE Basement Storage Room near tank 20 S.F. INSTALL WATERPROOFING PRIORITY 5 LEVEL 5 Deficiency Location/Instance Deficiency Quantity Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Basement Storage Room near tank Violations No violations recorded Inspected ROOF STRUCTURE Condition 2- Between Good and Fair Deficiency No deficiencies recorded VAULTS-BUNKERS Inspected Foundation Walls Inspected 3- Fair Condition Deficiency Deficiency Location/Instance Deficiency Quantity CRACKS, SPALLING Facade A 25 S.F. REPAIR PRIORITY 3 LEVEL 5 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected Slab Structure 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Vault/Ash Hoist Doors and Framing 5- Poor Condition Mobile Validity Version 2.0 (P) Page 23 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR STRUCTURAL VAULTS-BUNKERS Vault/Ash Hoist Doors and Framing DETERIORATED/DAMAGED VAULT/ASH HOIST DOORS AND FRAMING Facade A - Ash Hoist 2 EACH REPLACE PRIORITY 5 LEVEL 2 Deficiency Deficiency Location/Instance Deficiency Quantity Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Facade A - Ash Hoist Doors Violations No violations recorded Inspected TOILET ROOMS - STAFF Inspected Ceiling Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Door(s) Condition 5- Poor Deficiency Deficiency Location/Instance Deficiency Quantity WOOD:DETERIORATED DOOR Kitchen staff toilet room 1 EACH MAINTENANCE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Kitchen staff toilet room Violations No violations recorded Inspected Floor Finish Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Stalls Condition 5- Poor Deficiency Deficiency Location/Instance Deficiency Quantity RUST - MAJOR Rooms 237, 240 3 EACH REPLACE PRIORITY 3 Quantity Uom Potential Action Urgency of Action Mobile Validity Version 2.0 (P) Page 24 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR TOILET ROOMS - STAFF Stalls Purpose of Action Deficiency Photo 1 LEVEL 2 Room 237 Violations No violations recorded Inspected Walls Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected TOILET ROOMS - STUDENTS Inspected Ceiling Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Door(s) Condition 5- Poor Deficiency Deficiency Location/Instance Deficiency Quantity WOOD:DETERIORATED DOOR Room 257 1 EACH MAINTENANCE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Room 257 Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity METAL:DETERIORATED DOOR AND FRAME Inside Rooms 101, 142, 144, 146, Boys toilet room in Cafeteria 5 EACH MAINTENANCE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Inside Room 146 Mobile Validity Version 2.0 (P) Page 25 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response INTERIOR TOILET ROOMS - STUDENTS Door(s) Violations No violations recorded Inspected Floor Finish Condition 2- Between Good and Fair Deficiency Deficiency Location/Instance Deficiency Quantity CERAMIC TILE:BROKEN/MISSING TILES Rooms 114, 124, 253 30 S.F. REPLACE PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected Stalls Condition 2- Between Good and Fair Deficiency Deficiency Location/Instance Deficiency Quantity BROKEN/MISSING Room 214 1 EACH REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Room 214 Violations No violations recorded Inspected Walls Condition 2- Between Good and Fair Deficiency Deficiency Location/Instance Deficiency Quantity CERAMIC TILE:BROKEN/ MISSING Rooms 214, 224, 253, 314, 320 and other locations 50 S.F. REPLACE PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected LIFE SAFETY F.D. HOLDING AREA Does not exist STEEL STAIRS Does not exist Inspected SITE Inspected CONTAINERIZATION 5- Poor Condition Deficiency Deficiency Location/Instance Deficiency Quantity CONTAINER DAMAGED Schoolyard 1 EACH REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Mobile Validity Version 2.0 (P) Page 26 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response SITE CONTAINERIZATION Deficiency Photo 1 West side of schoolyard Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity FENCING MISSING Schoolyard 1,200 S.F. INSTALL NEW PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 West side of schoolyard Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity CONCRETE PAD MISSING Schoolyard 600 S.F. INSTALL NEW PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected Drainage System for Asphalt Inspected Catch Basins/Manhole - Surrounded by asphalt Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Drainage System for Concrete Inspected Catch Basins/Manhole - Surrounded by concrete Condition 5- Poor Deficiency Deficiency Location/Instance Deficiency Quantity BLOCKED Walkway from Exit 4 and 5 to Malcolm X Boulevard 1 EACH MAINTENANCE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Mobile Validity Version 2.0 (P) Page 27 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response SITE Drainage System for Concrete Catch Basins/Manhole - Surrounded by concrete Deficiency Photo 1 Walkway from Exit 4 and 5 to Malcolm X Boulevard Violations No violations recorded Inspected Drainage System for Soil Does not exist Catch Basins/Manhole - Surrounded by Soil DRINKING FOUNTAINS Does not exist FENCES Inspected 4- Between Fair and Poor Condition Deficiency Deficiency Location/Instance Deficiency Quantity WROUGHT IRON:DAMAGED/DETERIORATED Along Malcolm X Boulevard, Lafayette Avenue 200 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Along Malcolm X Boulevard Violations No violations recorded Deficiency Deficiency Location/Instance WROUGHT IRON:RUST - MAJOR Along Malcolm X Boulevard, at areaways near the flagpole and ash hoist 600 S.F. REPLACE PRIORITY 3 LEVEL 2 Deficiency Quantity Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Along Malcolm X Boulevard Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity CONCRETE CURB:DAMAGED/DETERIORATED Along Malcolm X Boulevard, Lafayette Avenue 60 S.F. Quantity Uom Mobile Validity Version 2.0 (P) Page 28 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response SITE FENCES Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 REPLACE PRIORITY 3 LEVEL 2 Malcolm X Boulevard Violations No violations recorded IRRIGATION SYSTEM Does not exist PAVING Inspected Inspected DOT Sidewalk Inspected Asphalt 3- Fair Condition Deficiency Deficiency Location/Instance Deficiency Quantity CRACKS - MINOR Along Lafayette Avenue 300 S.F. MAINTENANCE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Along Lafayette Avenue Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity CRACKS - MAJOR Along Lafayette Avenue near the main entrance. 100 S.F. REPLACE PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Deficiency Deficiency Location/Instance Deficiency Quantity DAMAGED CURBS Along Lafayette Avenue near the main entrance. 60 L.F. REPLACE PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected Concrete 4- Between Fair and Poor Condition Deficiency Deficiency Location/Instance Mobile Validity Version 2.0 (P) DAMAGED/DETERIORATED/MISSING SECTIONS Along Lafayette Avenue, Malcolm X Boulevard Page 29 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response SITE PAVING DOT Sidewalk Concrete Deficiency Quantity 2,000 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Along Malcolm X Boulevard Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity HEAVING Along Malcolm X Boulevard, Lafayette Avenue 300 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Along Malcolm X Boulevard Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity DAMAGED CURBS Along Lafayette Avenue 100 L.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Along Lafayette Avenue Violations No violations recorded Does not exist Pavers Inspected Site Sidewalks & Walkways Inspected Asphalt Mobile Validity Version 2.0 (P) Page 30 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response SITE PAVING Site Sidewalks & Walkways Asphalt Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Concrete 4- Between Fair and Poor Condition Deficiency Deficiency Location/Instance Deficiency Quantity CRACKS - MAJOR Entrance walkway to south side of school building 100 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Entrance walkway to south side of school building Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity DAMAGED/DETERIORATED/MISSING SECTIONS Schoolyard, walkway on west side of school 750 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Schoolyard Violations No violations recorded Deficiency Deficiency Location/Instance Deficiency Quantity DAMAGED CURBS Schoolyard 80 L.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Mobile Validity Version 2.0 (P) Page 31 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response SITE PAVING Site Sidewalks & Walkways Concrete Schoolyard Violations No violations recorded Inspected Pavers 3- Fair Condition Deficiency Deficiency Location/Instance Deficiency Quantity DAMAGED/MISSING Walkway on west side of school 100 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Walkway on west side of school Violations No violations recorded Inspected Student Non-Use Gravel Exists? No Inspected Asphalt 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Concrete 2- Between Good and Fair Condition Deficiency No deficiencies recorded Does not exist Pavers Inspected Student Use Gravel Exists? No Inspected Asphalt 4- Between Fair and Poor Condition Deficiency Deficiency Location/Instance Deficiency Quantity CRACKS - MAJOR Schoolyard 400 S.F. REPLACE PRIORITY 3 LEVEL 2 Quantity Uom Potential Action Urgency of Action Purpose of Action Deficiency Photo 1 Center of schoolyard Violations No violations recorded Deficiency Mobile Validity Version 2.0 (P) CRACKS - MINOR Page 32 of 33 Print Date: 6/16/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Architectural Inspection K026 Question Response SITE PAVING Student Use Asphalt Deficiency Location/Instance Deficiency Quantity Schoolyard 600 S.F. MAINTENANCE PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Concrete Does not exist Pavers Does not exist PLAYGROUNDS Does not exist PLAYING SURFACE Does not exist RETAINING WALLS Does not exist SEATING Does not exist SITE WALLS (NOT RETAINING WALLS) Does not exist STAIRS/RAMPS: EXTERIOR Does not exist Mobile Validity Version 2.0 (P) Page 33 of 33 Print Date: 6/16/2015