CC-Link IE - Mitsubishi Electric Australia
Transcription
CC-Link IE - Mitsubishi Electric Australia
2009 Mar Ethernet-based Open Network CC-Link IE Ethernet-based Open Network Advanced Gigabit Ethernet technology designed for achieving high speed and large data capacity CC-Link IE Controller Network modules CC-Link IE Controller Network interface boards On the shop floor, the amount of data that each controller exchanges with other devices or Enterprise information systems is increasing more than ever. Mitsubishi Electric supports the Gigabit industrial Ethernet open network to realize these growing demands in manufacturing. CC-Link IE based on Gigabit fiber optic Ethernet medium allows connection of various devices including 3rd party for achieving the high speed and large data capacity requirements. Gigabit Ethernet Standard type With external power supply function Reducing costs while improving cycle times Ethernet topology ● Ethernet topology (IEEE802.3) Utilizing Ethernet standard cables and connectors can achieve substantial reduction in costs. ● Multi-mode optical fiber (1000BASE-SX) ● LC connector (IEC61754-20) Standard type With external power supply function * * A communication unit for GOT is mounted. Evolution More troubleshooting functions for reducing communication time Visualization of network connection status High speed data update Visually displays a whole system's network connection status such as the error point when a trouble occurs. Maintenance cost can be reduced. Performance of cyclic data update of network type shared memory is enhanced. Transfer delay time is shortened and application waiting time also can be reduced. Large capacity memory Network type shared memory (cyclic data) with 256K bytes is realized on one network. Dividing network is not necessary so that a system that handles a large capacity data is easily realized. *1 Values are compared at a network configuration by 32 modules, with each station's LW2K points equally allocated, and without disconnected or reconnected stations. Large volume (8 times greater than conventional networks) *1 Ultra-high speed (14 times faster than conventional networks) *1 Enhances the check function of optical fiber Check function for detecting error points and wrongly inserted ports of optical fiber cable is enhanced. Efficient Error point Next generation deterministic network designed for the industrial world Error No complicated programming involved in configurating a network Easy data refresh of network shared memory Data consistency guaranteed by station Using read/write method of memory, data transmission is easy. No need for additional applications (user program) to assure consistency Automatic refresh between network shared memory and programmable controller device Sharing data between controllers is easy because there is no need to be conscious of the network. Stable operation with external power supply input Supports input of an external power supply to CC-Link IE Controller Network modules and interface boards. Even if the programmable controller CPU or personal computer is shut down, communication continues without having to rely on the 'loop back' function. External power supply External power supply Controller Network External power supply 1 External power supply External power supply External power supply 2 Ethernet-based Open Network CC-Link IE Ethernet-based Open Network Application Example : Automotive production line Its performance lives up to the name, “IE: Industrial Ethernet” Basic Specification Comparison Item CC-Link IE Controller Network MELSECNET/H Communication speed 1 Gbps 25 Mbps Number of LB points per network 32 K points 16 K points Number of LW points per network 128 K points 16 K points Number of stations per network 120 stations 64 stations Link scan time* Approx. 5 ms Approx. 70 ms*2 External power supply connectivity Available Available Interface board connectivity Available Available 1 CC-Link IE: High-speed network reliably carries huge amounts of data ●Faster speed: Shorter operation cycle improves productivity. ●Determinism: Stabilized operation cycle improves manufacturing quality. ●Large capacity: A large amount of data can be easily collected from the production equipment. ALC server Database server *1: 32 stations with 2K LW points per station system. Link scan time is calculated value (max. value). *2: Performance of MELSECNET/H beyond 16 K points is a calculated predicted value. Large amount of actual performance data and operation data Large-capacity data batch transmission Ethernet Provides a high-speed, large-capacity network through seamless communication across all layers Network shared memory (Cyclic data ) Controller Network ● Data sharing ● Data exchange ● Data sharing ● Data exchange ● Data sharing ● Data exchange ● Data sharing ● Data exchange ● Data sharing ● Data exchange ● Data sharing ● Data exchange Enterprise level network NEW Seamless communication Controller Network Power train machining Power train assembly Stamping Welding Painting Final assembly Control level network Device level network Sensor level network 3 4 Ethernet-based Open Network Performance Specifications Item Specification Maximum number of link points per network Maximum number of link points per station LB 32 K points (32,768 points, 4 KB) LW 128 K points (131,072 points, 256 KB) LX 8 K points (8,192 points, 1 KB) LY 8 K points (8,192 points, 1 KB) LB 16 K points (16,384 points, 2 KB) LW 16 K points (16,384 points, 32 KB) LX 8 K points (8,192 points, 1 KB) LY 8 K points (8,192 points, 1 KB) Transmission speed Group cyclic transmission Shared group No.1 Control station: No.1 LB0 1 Gbps Number of stations per network Connecting cable*1 120 stations max. Overall length (overall optical cable length) No.1 send range No.1 No.1 No.2 No.2 send range No.2 No.3 No.3 No.3 send range 66 km (when connecting to 120 stations) 550 m max. (core/clad = 50/125 µm) Duplex LC connector: IEC61754-20 Type LC connector, insertion loss: 0.3 dB max., polished surface: PC (physical contact) polishing Connector Maximum number of networks Dual loop Compatible CPU Universal model QCPU, High Performance model QCPU, Basic model QCPU*2 NEW , Process CPU NEW , Redundant CPU NEW , Safety CPU*2 NEW *1: For the recommended cables and other information, contact the CC-Link Partner Association. *2: For details, refer to the "CC-Link IE Controller Network Reference Manual (SH-080668ENG)". No.1 No.1 No.4 No.4 send range No.4 No.5 No.5 No.5 send range LB7FFF Product List Product name Functions Item Description ●Refreshes link relay/link registers assigned by network common parameters in all stations regularly. data link registers are guaranteed (data transmission is not divided into 16 bits). ●Communication data consistency is guaranteed by station. ●Group cyclic transmission*3 NEW ●32-bit ●N:N Transient transmission Others Normal station: No.5 32 Transmission path Data communication functions Normal station: No.4 239 Maximum number of groups Cyclic transmission Shared group No.2 Normal station: No.3 Link relay (LB) 1000BASE-SX (MMF) fiber optic cable: IEC60793-2-10 Types A1a.1 (50/125 µm multimode), transmission loss: 3.5 dB/km max. (λ= 850 nm),transmission band: 500 MHz·km min. (λ= 850 nm) Station-to-station distance Normal station: No.2 transition (monitor, program upload/download, etc.) ●Various dedicated instructions from the programmable controller program (READ, SREAD, WRITE, SWRITE, REQ, SEND, RECV, RECVS, ZNRD, ZNWR, RRUN, RSTOP, RTMRD, and RTMWR). ●Group function (multi-cast communication of transient transmission). ●Routing function (data communication can be established with stations on other network not directly connected). ●Points for link dedicated instruction: 8192 words NEW CC-Link IE Controller Network module CC-Link IE Controller Network interface board CC-Link IE Controller Network communication unit Model Outline QJ71GP21-SX QJ71GP21S-SX Q80BD-J71GP21-SX Q80BD-J71GP21S-SX GT15-J71GP23-SX NEW CC-Link IE Controller Network dual loop fiber optic interface module (1000BASE-SX)For control/normal station CC-Link IE Controller Network dual loop fiber optic interface module (1000BASE-SX)For control/normal station, with external power supply function CC-Link IE Controller Network dual loop fiber optic interface board for PC (1000BASE-SX) For control/normal station CC-Link IE Controller Network dual loop fiber optic interface board for PC (1000BASE-SX) For control/normal station, with external power supply function CC-Link IE Controller Network dual loop fiber optic communication unit for GOT (1000BASE-SX) For control/normal station, compatible model: GT15 ●Interrupt program (interruption during data reception from other stations). between data links (cyclic data is automatically transferred to other networks when multiple networks exist). ●Transmission ●Off-line test (H/W test, self-loopback test, etc.) diagnostics using GX Developer (monitoring network status and status of each station). ●Network diagnostics by SB/SW. ●Control station shifting function (control station substituting function at time of control station failure). ●Loopback function in the event of disconnection and duplexing. ●External power supply function (QJ71GP21S-SX、Q80BD-J71GP21S-SX). ●Improved fiber optic cable integrity monitoring (detecting cable fault and incorrect cable connection). ●Network RAS functions *3: It is a function to share cyclic data with stations in the same shared group. By receiving cyclic data from the stations in the shared group, the link refresh points are reduced, and the link refresh time is shortened. (This function can be used when the control station and the station to set the shared group are Universal model QCPU.) 5 6 Ethernet-based Open Network Interface Board Operating Environment Description Item CPU Personal computer Required memory PCI bus specifications Personal computer with one or more PCI bus slots, or server personal computer with one or more PCI-X bus slots, which meets the specifications of "Applicable operating system and required PC performance" shown below. MEMO 5 V or 3.3 V DC, 32-bit or 64-bit bus, Basic clock: 33 MHz, supporting PCI bus standard Rev.2.2 or later, supporting PCI-X bus standard 1.0 or later Resolution: 1024 × 768 dots or higher Display 80MB or more Hard disk space Disk drive CD-ROM disk drive Microsoft® Visual Basic® 6.0 (English version), Microsoft® Visual Basic® .NET 2003 (English version), Microsoft® Visual Studio 2005 Visual Basic® (English version), Microsoft® Visual C++® 6.0 (English version), Microsoft® Visual C++® .NET 2003 (English version), or Microsoft® Visual Studio 2005 Visual C++® (English version) Programming language Applicable operating system and required PC performance CPU Operating system Required memory Microsoft Windows 2000 Professional (English version) ® ® 256MB or more Microsoft® Windows® XP Professional (English version) Microsoft® Windows® XP Home Edition (English version) Microsoft® Windows® Server 2003 R2 (English version) PentiumIII® 1GHz or higher Microsoft® Windows Vista® Home Basic (English version) Microsoft Windows Vista Home Premium (English version) ® ® 512MB or more Microsoft® Windows Vista® Business (English version) Microsoft® Windows Vista® Ultimate (English version) Microsoft® Windows Vista® Enterprise (English version) Reference Manual for Interface Board Driver Development A "reference manual" to develop drivers compatible with various operation systems is provided for customers who intend to use the CC-Link IE Controller Network interface board in an operation system other than Windows. This reference manual contains the following information that is required for the driver development. Hardware information (PCI configuration, dual-port memory, I/O port memory map) Software information (Initial setting and parameter setting procedures for the driver) Driver (to be developed) Application Sample codes of the C language and their usage (included on the attached CD-ROM) Various OS other than Windows CC-Link IE Controller Network interface board Q80BD-J71GP21-SX * We will introduce entrusted partners for the software development if you wish. Document (reference manual) Manual name CC-Link IE Q80BD-J71GP21-SX Driver Development 7 Manual number SH-080819ENG 8 Guide to Partner Products Ethernet-based Open Network Cable Accessories CC-Link IE Controller Network Compatible Optical Fiber Cable QG Series * LCF connector: Double-row LC connector (IEC61754-20) Standard Accessories Protective holder (One protective holder is enclosed per cable.) Performance specifications Cable features 1. This optical fiber cable, recommended by the CC-Link Partner Association, can be used safely and worry-free. 2. A full lineup of cable is available, including types for use inside panels, indoors, outdoors, and reinforced type for outdoors, allowing use in various environments. 3. The newly developed thin cable (for indoor and outdoor use) incorporates a cord bundling structure, allowing safe use even in confined factory cable-laying environments. 4. The indoor use and outdoor use cables are free of tension members, and have an allowable tension equivalent to the reinforced type for outdoor use. 5. The outdoor use cable is waterproof, and can be used even in flooded or temporary submerged areas. 6. By attaching the enclosed protective holder (patent pending), breakage at the connector base can be prevented and space in the panel can be saved. 7. A connector boot, with improved bending characteristics, reduces breakage at the connector base. Optional Parts Relay adaptor Connector insertion tool SPAD-LCF-G50 SCT-SLM Item Single mode optical fiber cable dedicated port (OPT1 port) Multi-mode optical fiber cable dedicated port (OPT2 port) Compliant Standards IEEE802.3z Gigabit Ethernet (1000BASE-LX) Full duplex method Transmission method Applicable optical fiber IEEE802.3z Gigabit Ethernet (1000BASE-SX) 1.25Gbps Transmission speed (NRZ) 1000BASE-LX compatible single mode optical fiber cable 1000BASE-SX compatible multi-mode optical fiber cable (band 500MHz·km or more, λ = 850nm) Send/receive connectors, one port each (total two ports) Interface Applicable connector Double SC connector (IEC61754-4)*2 Double LC connector (IEC61754-20) Connector polishing method PC, SPC, AdPC, UPC polishing PC polishing Light projecting center wavelength 1270 to 1360nm 820 to 860nm Light receiving wavelength 1100 to 1600nm 770 to 860nm Light projecting level -3 to -10dBm -4 to -9.5dBm Light receiving level -3 to -20dBm 0 to -17dBm Allowable light loss 0 to 10dB 0 to 7.5dB Reference transmission distance 550m (max.) 2m to 15km * 1 *1: Guide when connected to same model. When connecting to a different 1000BASE-LX compatible unit, the distance is 5km. *2: When connecting with CC-Link IE, the single-end double LC connector and single-end double SC connector optical fiver cable is used. Power specifications Item Rated input voltage • Protects connector base, and prevents breakage • Maintains minimum bending radius • Saves space in control panel (60mm or less from front of PLC to end of protective holder) Caution: The protective holder is dedicated for the Mitsubishi Electric System Service Co., Ltd. LCF connector, and is not available as a single unit. It cannot be mounted on other LCF connector brands. Media Converter Applications: • Extends optical fiber cable (relay connection) • Temporary connection for stations which may be extended later Applicable connector: • LCF connector (insertion loss: 0.3dB or less *1) *1: Using master fiber Application: • Insertion and removal of connector at small spaces such as slots on back of personal computer Applicable connector: • LCF/LC/SC/MU connector DMC-1000SL 100 to 120VAC 1.5A or less – Rated input frequency – 50/60Hz 3.2 to 3.6VDC 90 to 132VAC Power consumption (DC section) Apparent power 5.0W or less – – 11VA or less For details of Mitsubishi Electric System & Service Co., Ltd. products, contact us by sending an e-mail to the following address. <Sales office> FA PRODUCT DIVISION mail:oss-ip@melsc.jp From promotion to specification development, the CLPA supports the spread of CC-Link. Features CC-Link IE Controller Network Compatible Optical Media Converter AC power rating (AC adaptor) 3.3VDC Current consumption Voltage range Applications: DC power rating If the distance between stations is separated by 550m or more (between factory A and C, between factory B and C), the maximum distance between stations can be extended up to 15km by inserting two of these products and connecting with single mode optical fiber cables. CC-Link IE Controller Network communication configuration CC-Link Partner Association The Japan-original open field network, CC-Link. CLPA (CC-Link Partner Association), in which Mitsubishi Electric also participates, was established with a view to spreading CC-Link to the world. Through vigorous activities such as planning and running trade shows and seminars, conducting conformance tests, and providing information by catalogs, pamphlets, and the Internet, the number of CLPA partner manufacturers and CC-Link compatible products is increasing steadily, and the CLPA is becoming a driving force for the globalization of CC-Link. Conformance tests support the rapid increase of compatible products. Exhibitions and seminars are held to recruit new partner members. Multi-mode optical fiber cable Max. 550m Factory A 1000BASE-SX 9 1000BASE-LX conversion Single mode optical fiber cable Max. 15km Factory C Factory B Single mode optical fiber cable Max. 15km This web site provides the latest CC-Link information. 6F Meiji Yasuda Seimei Ozone Bldg., 3-15-58, Ozone, Kita-ku, Nagoya 462-0825, Japan TEL : +81-52-919-1588 FAX : +81-52-916-8655 URL : http://www.cc-link.org E-mail : cc-link.@post0.mind.ne.jp 10 Ethernet-based Open Network CC-Link IE This catalog explains the typical features and functions of the MELSEC-Q Series programmable controllers and CC-Link IE Controller Network modules and does not provide restrictions and other information on usage and module combinations. When using the products, always read the user's manuals of the products. Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties. L (NA)08111E-B 0903 (MDOC) New publication, effective Mar. 2009 Specifications subject to change without notice.