Stainless Steel Filters
Transcription
Stainless Steel Filters
INTERNORMEN Edelstahlfilter Stainless Steel Filters Wir schaffen Reinheit in Ihrem System • • • • Optimierte Baureihen Modulare Bauweise Komfortable Bedienung und einfache Wartung Qualitativ hochwertige Elemente We generate cleanliness in your system • • • • Optimised efficiency ranges Modular construction Comfortable operation and easy service High-quality elements Filterbaureihen Filter Types Beschreibung Edelstahl-Filter von INTERNORMEN Technology sind geeignet für den Einsatz der Medien Wasser und Emulsionen in der Offshore-Technik, der Chemieindustrie, der Lebensmittelindustrie und in Fällen extremer Außen- und Umweltbedingungen. Description Stainless steel filters from INTERNORMEN Technology are applicable for water and emulsions in the offshore technology, chemical industry, the food industry and in cases of extreme outdoor and environmental conditions. Edelstahlfilter zum Einbau in die Druckleitung Stainless steel filters for mounting in pressure lines Baugröße Anschluß Nenndruck in bar Filterfläche in cm² EdelstahlGewebe model No. port size working pressure MaßblattNr. Glasfaser filtration area cm² bar stainless steel wire mesh glass fibre data sheet No. EH-Gruppe / EH group EH 31 G 1/2 420 410 490 1435 EH 60 G 1/2 420 520 800 1430 EH 90 G 3/4 420 860 1330 1430 EH 150 G1 420 1440 2229 1430 EH 240 G 1 1/2, SAE 1 1/2” 420 1600 2581 1431 EH 450 G 1 1/2, SAE 1 1/2” 420 2980 4795 1431 EH 601 SAE 2” 315 3440 5606 1434 EH 901 SAE 2” 315 4980 8079 1434 EH 1351 SAE 2” 315 7410 12939 1434 Edelstahlfilter, umschaltbar Bestehend aus 2 Kammern, von denen sich eine Kammer in Funktion befindet, während die andere abgeschaltet ist. Dadurch kann das verschmutzte Filterelement ohne Betriebsunterbrechung ausgetauscht werden. Der Einbau kann in eine Saug-, Druck- oder Rücklaufleitung erfolgen. Stainless steel filter, change-over Flow path through the filter can be changed to either of the two chambers. The dirty element can be serviced/changed while in the “off” position without interrupting the operation. Can be mounted in suction, pressure or return lines. Baugröße Anschluß Nenndruck in bar Filterfläche * in cm² EdelstahlGewebe model No. port size working pressure bar MaßblattNr. Glasfaser filtration area cm² stainless steel wire mesh glass fibre data sheet No. EHD 91 G1 315 860 1330 2530 EHD 151 G1 315 1440 2229 2530 EHD 241 SAE 1 1/2” 315 1600 2581 2533 EHD 451 SAE 1 1/2” 315 2980 4795 2533 * Filterfläche: je Filterseite filtration area: per each filter side Titelseite: “Werksfoto Lurgi” title page: “photo Lurgi” EHD 241 Filterprüfung und Qualitätskontrolle nach ISO Filter testing and quality control according to ISO standards. Edelstahlfilter, umschaltbar Stainless steel filter, change-over Baugröße Anschluß Nenndruck in bar Filterfläche * in cm² EdelstahlGewebe model No. port size working pressure MaßblattNr. Glasfaser filtration area cm² bar stainless steel wire mesh glass fibre data sheet No. EDU 251 EDU 251 SAE 2” 25 3070 4672 2124 EDU 401 SAE 2” 25 5020 7612 2124 EDU 635 SAE 2 1/2” 25 6000 9978 2150 EDA 100/101 SAE 1”, ANSI 1” 40/20 1490 2920 2159/2168 EDA 250/251 SAE 2”, ANSI 2” 40/20 3070 4672 2157/2169 EDA 400/401 SAE 2”, ANSI 2” 40/20 5020 7612 2157/2169 EDA 630/631 SAE 3”, ANSI 3” 40/20 6000 9978 2158/2170 EDA 1000/1001 SAE 3”, ANSI 3” 40/20 8050 15760 2158/2170 DN 50, 65, 80, 100 16 11160 18018 EDSF 2001 DN 65, 80, 100, 125 16 17570 29630 EDSF 2401 DN 65, 80, 100, 125, 150 16 22320 36036 EDSF 3601 DN 80, 100, 125, 150 16 33480 54054 EDSF 4001 DN 65, 80, 100, 125 16 35140 59262 16 44640 72072 16 52710 88890 16 87850 148150 EDSF 1201 DN 100, 125, 150, 200 DN 100, 125, 150, 200 DN 125, 150, 200, 250 EDSF 4801 EDSF 6001 EDSF 10001 EDU 635 2161 Edelstahl-Filterbatterie Hohe Filterleistung bei großen Volumenströmen Stainless steel filter battery High filter efficiency at high volume flows Baugröße Anschluß Nenndruck in bar Filterfläche * in cm² EdelstahlGewebe model No. port size working pressure Glasfaser filtration area cm² bar stainless steel wire mesh glass fibre EBHDD 2 x 901 AVIT 2” 315 2 x 4980 2 x 8079 EBHDD 3 x 901 AVIT 2 1/2” 315 3 x 4980 3 x 8079 EBHDD 4 x 901 AVIT 3” 315 4 x 4980 4 x 8079 * Filterfläche: je Filterseite MaßblattNr. data sheet No. Filterbatterie Filter battery BEHD 4 x 901 2526 Weitere Baureihen auf Anfrage Other ranges on request! filtration area: per each filter side Edelstahlfilter Zum Einbau in die Saug-, Druck- und Rücklaufleitung Stainless Steel Filter For mounting in suction, pressure and return lines Baugröße Anschluß Nenndruck in bar Filterfläche in cm² EdelstahlGewebe model No. port size working pressure bar Glasfaser filtration area cm² stainless steel wire mesh glass fibre 1201 DN 50, 65, 80, 100 16 11160 18018 ELF 2001 DN 65, 80, 100, 125 16 17570 29630 ELF 2401 DN 65, 80, 100, 125 16 22320 36036 ELF 3601 DN 80, 100, 125, 150 16 33480 54054 ELF 4801 16 44640 72072 ELF 6001 16 52710 88890 16 87850 148150 ELF 10001 data sheet No. ELF 2001 ELF DN 100, 125, 150, 200 DN 100, 125, 150, 200 DN 125, 150, 200, 250 MaßblattNr. Vertrauen ist gut, Kontrolle ist besser! Reinheitsklassenermittlung mit unserem CCS 2. 1130 Reliance is good, control is better! Contamination determination with our CCS 2. Edelstahlfilter im Einsatz für Wasserhydraulik D/GB-01/2009 316026 Stainless steel filters in use in water hydraulics INTERNORMEN Technology GmbH Friedensstrasse 41 • D-68804 ALTLUSSHEIM - GERMANY Tel.: +49 (0) 6205 2094-0 • Fax: +49 (0) 6205 2094-40 Internet: www.internormen.com • e-mail: info@internormen.com Sheet No. STAINLESS STEEL-PRESSURE FILTER Series EH 31 DN 15 1435 C PN 420 1. Type index: 1.1. Complete filter: (ordering example) EH . 31. 10VG. HR. E. P. VA. G. 3. VA. -. AE 1 2 3 4 5 6 7 8 9 10 11 12 1 series: EH = stainless steel-pressure filter 2 nominal size: 31 3 filter-material and filter-fineness: 80G = 80 µm, 40G = 40 µm, 25G = 25 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 4 resistance of pressure difference for filter element: 30 = ∆p 30 bar HR = ∆p 160 bar (rupture strength ∆p 250 bar) 5 filter element design: E = single-end open 6 sealing material: P = Nitrile (NBR) V = Viton (FPM) 7 filter element specification: (see catalog) = standard VA = stainless steel IS06 = see sheet-no. 31601 8 connection: G = thread connection according to ISO 228 NPT = thread connection 9 connection size: 3 = ½“ 10 filter housing specification: VA = stainless steel 11 internal valve: = without S1 = with by-pass valve ∆p 3,5 bar S2 = with by-pass valve ∆p 7,0 bar 12 clogging indicator or clogging sensor: = without AOR = visual, see sheet-no. 1606 AOC = visual, see sheet-no. 1606 AE = visual-electrical, see sheet-no. 1615 VS1 = electronical, see sheet-no. 1617 VS2 = electronical, see sheet-no. 1618 1.2. Filter element: (ordering example) 01E. 30. 10VG. HR. E. P. VA 1 2 3 4 5 6 7 1 series: 01E. = filter element according to INTERNORMEN factory specification 2 nominal size: 30 3 - 7 see type index-complete filter weight: approx. 3,0 kg Changes of measures and design are subject to alteration! EDV 11/07 Friedensstrasse 41, 68804 Altlussheim, Germany phone fax +49 - (0)6205 - 2094-0 +49 - (0)6205 - 2094-40 e-mail url sales@internormen.com www.internormen.com 2. Spare parts: item 1 2 3 4 5 6 7 8 9 10 11 12 qty. 1 1 1 1 1 1 1 1 1 1 1 1 designation filter element O-ring O-ring support ring clogging indicator, visual clogging indicator, visual-electrical clogging sensor, electronical clogging sensor, electronical O-ring O-ring O-ring screw plug dimension 01E. 30 11 x 3 40 x 3 48 x 2,6 x 1 AOR or AOC AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 20913-4 article-no. 312603 (NBR) 304389 (NBR) 312727 (FPM) 304391 (FPM) 305391 see sheet-no. 1606 see sheet-no. 1615 see sheet-no. 1617 see sheet-no. 1618 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 314442 item 12 execution only without clogging indicator or clogging sensor 3. Description: The pressure filters of the series EH 31 are suitable for a working pressure up to 420 bar. The pressure peaks are absorbed by a sufficient margin of safety. The EH-filter is in-line mounted. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside. Filter elements are available down to 4 µm(c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available up to a pressure difference resistance of ∆p 160 bar and a rupture strength of ∆p 250 bar. The internal valves are integrated into the centering pivot for the filter element. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter. 4. Technical data: temperature range: operating medium: max. operating pressure: test pressure: connection system: housing material: sealing material: installation position: volume tank: -10°C to + 80°C (for a short time + 100°C) mineral oil, other media on request 420 bar 546 bar thread connection DIN 17440 - 1.4571 (320 S 18, 320 S 31 according to B.S.) Nitrile (NBR) or Viton (FPM), other materials on request vertical 0,12 l Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). 5. Symbols: without indicator with electrical indicator AE 30 and AE 40 with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with visual indicator AOR/AOC with electronical clogging sensor VS1 with electronical clogging sensor VS2 filter without internal valve filter with by-pass valve 6. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p-curves; depending on filter fineness and viscosity. 7. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 E 1435 C Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration performance Sheet No. STAINLESS STEEL- PRESSURE FILTER 1430 L Series EH 60-150 DN 15-25 PN 420 1. Type index: 1.1. Complete filter: (ordering example) EH. 90. 10VG. HR. E. P. VA. G. 4. VA. -. AE 1 1 2 3 4 5 6 7 8 9 10 11 12 series: EH = stainless steel-pressure filter nominal size: 60, 90, 150 2 3 filter-material and filter-fineness: 80G = 80 µm, 40G = 40 µm, 25G = 25 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 4 resistance of pressure difference for filter element: 30 = ∆p 30 bar HR = ∆p 160 bar (rupture strength ∆p 250 bar) 5 filter element design: E = single-end open 6 sealing material: P = Nitrile (NBR) V = Viton (FPM) 7 filter element specification: (see catalog) = standard VA = stainless steel IS06 see sheet-no. 31601 8 connection: G = thread connection according to ISO 228 NPT = thread connection according to ANSI B1.20.1 9 connection size: 3 = ½“ 4 = ¾“ 5 = 1“ 10 filter housing specification: VA = stainless steel 11 internal valve: = without S1 = with by-pass valve ∆p 3,5 bar S2 = with by-pass valve ∆p 7,0 bar R = reversing valve, Q ≤ 70,06 l/min 12 clogging indicator or clogging sensor : = without AOR = visual, see sheet-no. 1606 AOC = visual, see sheet-no. 1606 AE = visual-electrical, see sheet-no. 1615 VS1 = electronical, see sheet-no. 1617 VS2 = electronical, see sheet-no. 1618 1.2. Filter element: (ordering example) 01E. 90. 10VG. HR. E. P. VA 1 1 2. Dimensions: type EH 60 EH 90 EH 150 connection ½“ ¾“ 1“ A 195 260 370 B 78 78 84 C 215 280 390 1) D 30 36,5 40 2 3 4 5 6 7 2 series: 01E. = filter element according to INTERNORMEN factory specification nominal size: 60, 90, 150 3 - 7 E 20 20 23 see type index-complete filter F 90 90 95 G 82 82 84 weight kg 8,5 9,5 12,5 volume tank 0,3 l 0,4 l 0,6 l Connection assignments as showwn in the table are standard. To exchange connections see item 9 in type index. 1) dimension only with execution according to ISO 228 Changes of measures and design are subject to alteration! EDV 12/10 Friedensstrasse 41, 68804 Altlussheim, Germany phone fax +49 - (0)6205 - 2094-0 +49 - (0)6205 - 2094-40 e-mail url sales@internormen.com www.internormen.com 3. Spare parts: item qty. 1 2 3 4 5 6 7 8 9 10 11 12 1 1 1 1 1 1 1 1 1 1 1 1 designation EH 60 01E.60 filer element O-ring O-ring support ring clogging indicator, visual clogging indicator, visual-electrical clogging sensor, electronical clogging sensor, electronical O-ring O-ring O-ring screw plug dimension EH 90 EH 150 01E.90 01E.150 22 x 3,5 56 x 3 63 x 2,6 x 1 AOR or AOC AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 20913-4 article-no. 304341 (NBR) 305072 (NBR) 304392 (FPM) 305322 (FPM) 312309 see sheet no. 1606 see sheet no. 1615 see sheet no. 1617 see sheet no. 1618 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 314442 item 12 execution only without clogging indicator or clogging sensor 4. Description: The pressure filters of the series EH are suitable for a working pressure up to 420 bar. The pressure peaks are absorbed by a sufficient margin of safety. The EH-filter is in-line mounted. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to inside. Filter elements are available down to a filter fineness of 4µm (c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt-retaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available up to a pressure difference resistance of ∆p 160 bar and a rupture strength of ∆p 250 bar. The internal valves are integrated into the centering pivot for the filter element. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter. With the reverse valve a protection of the filter element is given when having a reverse flow inside the filter. The reverse flow will not be filtered. 5. Technical data: temperature range: operating medium: max. operating pressure: test pressure: connection system: housing material: sealing material: installation position: - 10°C to +80°C (for a short time +100°C) mineral oil, other media on request 420 bar 546 bar thread connection according to ISO 228 or ANSI B1.20.1 DIN 17440 - 1.4571 (320 S 18, 320 S 31 according to B.S.) Nitrile (NBR) or Viton (FPM), other materials on request vertical Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). 6. Symbols: without indicator with electrical indicator AE 30 and AE 40 with visual-electrical indicator AE 50 and AE 62 with visualelectrical indicator AE 70 and AE 80 with visual indicator AOR/AOC with electronical clogging sensor VS1 with electronical clogging sensor VS2 filter without internal valve filter with by-pass valve filter with reversing valve 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p-curves; depending on filter fineness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 E 1430 L Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration performance Sheet No. STAINLESS STEEL- PRESSURE FILTER 1431 H Series EH 240 - 450 DN 40 PN 420 1. Type index: 1.1. Complete filter: (ordering example) EH. 240. 10VG. HR. E. P. VA. FS. 7. VA. -. AE 1 2 3 4 5 6 7 8 9 10 11 12 1 series: EH = stainless steel-pressure filter 2 nominal size: 240, 450 3 filter-material and filter-fineness: 80G = 80 µm, 40G = 40 µm, 25G = 25 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) resistance of pressure difference for filter element: 30 = ∆p 30 bar HR = ∆p 160 bar (rupture strength ∆p 250 bar) 4 5 filter element design: E = single-end open 6 sealing material: P = Nitrile (NBR) V = Viton (FPM) 7 filter element specification: (see catalog) = standard VA = stainless steel IS06 see sheet-no. 31601 8 connection: G = thread connection (only with counter flange) FS = SAE-flange connection 6000 PSI 9 connection size: 7 = 1 ½“ 10 filter housing specification: VA = stainless steel 11 internal valve: = without S1 = with by-pass valve ∆p 3,5 bar S2 = with by-pass valve ∆p 7,0 bar R = reversing valve, Q ≤ 211,008 l/min 12 clogging indicator or clogging sensor : = without AOR = visual, see sheet-no. 1606 AOC = visual, see sheet-no. 1606 AE = visual-electrical, see sheet-no. 1615 VS1 = electronical, see sheet-no. 1617 VS2 = electronical, see sheet-no. 1618 1.2. Filter element: (ordering example) 01E. 240.10VG. HR. E. P. VA 1 1 2 3 4 5 6 7 series: 01E. = filter element according to INTERNORMEN factory specification 2 nominal size: 240, 450 3 - 7 see type index-complete filter 2. Dimensions: type EH 240 EH 450 connection G1 ½ or SAE 1 ½“ A 380 565 B 330 515 C 320 500 weight kg 22 30 volume tank 0,85 l 1,55 l Changes of measures and design are subject to alteration! EDV 11/07 Friedensstrasse 41, 68804 Altlussheim, Germany phone fax +49 - (0)6205 - 2094-0 +49 - (0)6205 - 2094-40 e-mail url sales@internormen.com www.internormen.com 3. Spare parts: item qty. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 1 1 1 1 1 1 1 1 1 1 1 1 1 designation dimension EH 240 EH 450 01E. 240 01E. 450 34 x 3,5 76 x 4 84 x 3,2 x 1,5 47,22 x 3,53 SAE 1 ½“ AOR or AOC AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 20913-4 filter element O-ring O-ring support ring O-ring (only with counter flange) counter flange 6000 PSI clogging indicator, visual clogging indicator, visual-electrical clogging sensor, electronical clogging sensor, electronical O-ring O-ring O-ring screw plug article-no. 304341 (NBR) 305072 (NBR) 304392 (FPM) 305322 (FPM) 312309 305078 (NBR) 310269 (FPM) 312406 see sheet no. 1606 see sheet no. 1615 see sheet no. 1617 see sheet no. 1618 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 314442 item 14 execution only without clogging indicator or clogging sensor 4. Description: The pressure filters of the series EH are suitable for a working pressure up to 420 bar. The pressure peaks are absorbed by a sufficient margin of safety. The EH-filters are flange mounted to the hydraulic system. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to inside. Filter elements are available down to a filter fineness of 4µm (c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt-retaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available up to a pressure difference resistance of ∆p 160 bar and a rupture strength of ∆p 250 bar. The internal valves are integrated into the centering pivot for the filter element. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter. With the reverse valve a protection of the filter element is given when having a reverse flow inside the filter. The reverse flow will not be filtered. 5. Technical data: temperature range: operating medium: max. operating pressure: test pressure: connection system: housing material: sealing material: installation position: -10°C to +80°C (for a short time +100°C) mineral oil, other media on request 420 bar 546 bar thread connection or SAE-flange connection 6000 PSI DIN 17440 - 1.4571 (320 S 18, 320 S 31 according to B.S.) Nitrile (NBR) or Viton (FPM), other materials on request vertical Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). 6. Symbols: without indicator with electrical indicator AE 30 and AE 40 with visual-electrical indicator AE 50 and AE 62 with visualelectrical indicator AE 70 and AE 80 with visual indicator AOR/AOC with electronical clogging sensor VS1 with electronical clogging sensor VS2 filter without internal valve filter with by-pass valve filter with reversing valve 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p-curves; depending on filter fineness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 E 1431 H Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration performance Sheet No. STAINLESS STEEL- PRESSURE FILTER Series 1434 F EH 601-1351 DN 50 PN 315 1. Type index: 1.1. Complete filter: (ordering example) EH. 901. 10VG. HR. E. P. VA. FS. 8. VA. -. AE 1 2 3 4 5 6 7 8 9 10 11 12 1 series: EH = stainless steel-pressure filter 2 nominal size: 601, 901, 1351 3 filter-material and filter-fineness: 80G = 80 µm, 40G = 40 µm, 25G = 25 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) resistance of pressure difference for filter element: 30 = ∆p 30 bar HR = ∆p 160 bar (rupture strength ∆p 250 bar) 4 5 filter element design: E = single-end open 6 sealing material: P = Nitrile (NBR) V = Viton (FPM) 7 filter element specification: (see catalog) = standard VA = stainless steel IS06 see sheet-no. 31601 8 connection: FS = SAE-flange connection 6000 PSI 9 connection size: 8 = 2“ 10 filter housing specification: VA = stainless steel 11 internal valve: = without S1 = with by-pass valve ∆p 3,5 bar S2 = with by-pass valve ∆p 7,0 bar R = reversing valve, Q ≤ 465,348 l/min 12 clogging indicator or clogging sensor : = without AOR = visual, see sheet-no. 1606 AOC = visual, see sheet-no. 1606 AE = visual-electrical, see sheet-no. 1615 VS1 = electronical, see sheet-no. 1617 VS2 = electronical, see sheet-no. 1618 1.2. Filter element: (ordering example) 01E. 900.10VG. HR. E. P. VA 1 1 2 3 4 5 6 7 series: 01E. = filter element according to INTERNORMEN factory specification 2 nominal size: 600, 900, 1350 3 - 7 see type index-complete filter 2. Dimensions: type connection A B weight kg volume tank EH 601 SAE 2“ 520 790 49 2,1 l EH 901 SAE 2“ 670 940 56 3,1 l EH 1351 SAE 2“ 918 1440 68 4,6 l Changes of measures and design are subject to alteration! EDV 11/07 Friedensstrasse 41, 68804 Altlussheim, Germany phone fax +49 - (0)6205 - 2094-0 +49 - (0)6205 - 2094-40 e-mail url sales@internormen.com www.internormen.com 3. Spare parts: item qty. 1 2 3 4 5 6 7 8 9 10 11 12 13 1 1 1 1 1 1 1 1 1 1 1 1 1 designation EH 601 01E.600 filer element O-ring O-ring support ring clogging indicator, visual clogging indicator, visual-electrical clogging sensor, electronical clogging sensor, electronical O-ring O-ring O-ring screw plug screw plug dimension EH 901 EH 1351 01E.900 01E.1350 48 x 3 98 x 4 110 x 3,5 x 2 AOR or AOC AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 20913-4 G½ article-no. 304357 (NBR) 301914 (NBR) 304404 (FPM) 304765 (FPM) 304802 see sheet no. 1606 see sheet no. 1615 see sheet no. 1617 see sheet no. 1618 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 314442 306966 item 12 execution only without clogging indicator or clogging sensor 4. Description: The pressure filters of the series EH are suitable for a working pressure up to 315 bar. The pressure peaks are absorbed by a sufficient margin of safety. The EH-filters are flange mounted to the hydraulic system. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside. Filter elements are available down to 4 µm(c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available up to a pressure difference resistance of ∆p 160 bar and a rupture strength of ∆p 250 bar. The internal valves are integrated into the centering pivot for the filter element. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter. With the reverse valve a protection of the filter element is given when having a reverse flow inside the filter. The reverse flow will not be filtered. 5. Technical data: temperature range: operating medium: max. operating pressure: test pressure: connection system: housing material: sealing material: installation position: -10°C to + 80°C (for a short time + 100°C) mineral oil, other media on request 315 bar 410 bar SAE-flange connection 6000 PSI DIN 17440 - 1.4571 (320 S 18, 320 S 31 according to B.S.) Nitrile (NBR) or Viton (FPM), other materials on request vertical Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). 6. Symbols: without indicator with electrical indicator AE 30 and AE 40 with visual-electrical indicator AE 50 and AE 62 with visualelectrical indicator AE 70 and AE 80 with visual indicator AOR/AOC with electronical clogging sensor VS1 with electronical clogging sensor VS2 filter without internal valve filter with by-pass valve filter with reversing valve 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p-curves; depending on filter fineness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 E 1434 F Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration performance Sheet No. STAINLESS STEEL- PRESSURE FILTER Series EHP 60-90 DN 15 1436 B PN 700/1400 1. Type index: 1.1. Complete filter: (ordering example) EHP. 90. 10VG. HR. E. P. VA. NPT. 3. VA. 700 1 2 3 4 5 6 7 8 9 10 1 series: EHP = stainless steel-pressure filter 2 nominal size: 60, 90 3 filter-material and filter-fineness: 80G = 80 µm, 40G = 40 µm, 25G = 25 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) resistance of pressure difference for filter element: 30 = ∆p 30 bar HR = ∆p 160 bar (rupture strength ∆p 250 bar) 4 5 filter element design: E = single-end open 6 sealing material: P = Nitrile (NBR) V = Viton (FPM) 7 filter element specification: (see catalog) = standard VA = stainless steel IS06 see sheet-no. 31601 8 connection: NPT = thread connection 9 connection size: 3 = NPT ½ 10 filter housing specification: VA = stainless steel 11 pressure level: 700 = max. operating pressure 700 bar 1400 = max. operating pressure 1400 bar 11 1.2. Filter element: (ordering example) 01E. 90. 10VG. HR. E. P. VA 1 1 2 3 4 5 6 7 series: 01E. = filter element according to INTERNORMEN factory specification 2 nominal size: 60, 90 3 - 7 see type index-complete filter 2. Dimensions: type A B C weight kg volume tank EHP 60 261 238 360 8,5 0,3 l EHP 90 326 303 425 9,7 0,4 l Changes of measures and design are subject to alteration! EDV 08/07 Friedensstrasse 41, 68804 Altlussheim, Germany phone fax +49 - (0)6205 - 2094-0 +49 - (0)6205 - 2094-40 e-mail url sales@internormen.com www.internormen.com 3. Spare parts: item 1 2 3 4 qty. 1 1 1 1 designation dimension EHP 60 01E.60 filer element O-ring O-ring support ring article-no. EHP 90 01E.90 22 x 3,5 45 x 3 52 x 2,6 x 1 304341 (NBR) 304991 (NBR) 304392 (FPM) 304997 (FPM) 311013 4. Description: The pressure filters of the series EHP are suitable for a working pressure up to 700 respectively 1400 bar. The pressure peaks are absorbed by a sufficient margin of safety. The EHP-filter is in-line mounted. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to inside. Filter elements are available down to a filter fineness of 4µm (c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt-retaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available up to a pressure difference resistance of ∆p 160 bar and a rupture strength of ∆p 250 bar. 5. Technical data: temperature range: operating medium: max. operating pressure: test pressure: connection system: housing material: sealing material: installation position: - 10°C to +80°C (for a short time +100°C) mineral oil, other media on request 700 bar 1400 bar 1000 bar 2000 bar thread connection EN10088-3 - 1.4418 + QT900 Nitrile (NBR) or Viton (FPM), other materials on request vertical Pressure stage 700: Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para 3. Pressure stage 1400: Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para 1.1.b) Category I (Modul A) Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). 6. Symbol: 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p-curves; depending on filter fineness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 E 1436 B Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration performance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over 2530 E Series EHD 61-151 DN 25 PN 315 1. Type index: 1.1. Complete filter: (ordering example) EHD. 91. 10VG. HR. E. P. VA. G. 5. VA. -. AE 1 2 3 4 5 6 7 8 9 10 11 12 1 series: EHD = stainless steel-pressure filter, change-over 2 nominal size: 61, 91, 151 3 filter-material and filter-fineness: 80G = 80 µm, 40G = 40 µm, 25G = 25 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) resistance of pressure difference for filter element: 30 = ∆p 30 bar HR = ∆p 160 bar (rupture strength ∆p 250 bar) 4 5 filter element design: E = single-end open 6 sealing material: P = Nitrile (NBR) V = Viton (FPM) 7 filter element specification: (see catalog) = standard VA = stainless steel IS06 see sheet-no. 31601 8 connection: G = thread connection according to ISO 228 9 connection size: 5 = G1 10 filter housing specification: VA = stainless steel 11 internal valve: = without S1 = with by-pass valve ∆p 3,5 bar S2 = with by-pass valve ∆p 7,0 bar R = reversing valve, Q ≤ 70,06 l/min 12 clogging indicator or clogging sensor : = without AOR = visual, see sheet-no. 1606 AOC = visual, see sheet-no. 1606 AE = visual-electrical, see sheet-no. 1615 VS1 = electronical, see sheet-no. 1617 VS2 = electronical, see sheet-no. 1618 1.2. Filter element: (ordering example) 01E. 90. 10VG. HR. E. P. VA 1 1 Pos. I: left filter-side in operation Pos. II: right filter-side in operation Connection V and VI to be used to bleed filter or to relieve pressure 2 3 4 5 6 7 series: 01E. = filter element according to INTERNORMEN factory specification 2 nominal size: 60, 90, 150 3 - 7 see type index-complete filter 2. Accessories: - measure- and bleeder connection, see sheet-no. 1650 3. Dimensions: type EHD 61 EHD 91 EHD 151 connection G1 A 224 289 399 B 210 340 450 weight kg 30 32 35 volume tank 2x 0,25 l 2x 0,4 l 2x 0,6 l Changes of measures and design are subject to alteration! EDV 04/08 Friedensstrasse 41, 68804 Altlussheim, Germany phone fax +49 - (0)6205 - 2094-0 +49 - (0)6205 - 2094-40 e-mail url sales@internormen.com www.internormen.com 4. Spare parts: item qty. designation 1 2 filter element 2 2 O-ring 3 2 O-ring 4 2 support ring 5 3 O-ring 6 2 support ring 7 4 O-ring 8 4 O-ring 9 4 O-ring 10 2 screw plug 11 2 screw plug 12 1 clogging indicator, visual 13 1 clogging indicator, visual-electrical 14 1 clogging sensor, electronical 15 1 clogging sensor, electronical 16 1 O-ring 17 1 O-ring 18 1 O-ring 19 1 screw plug 20 1 pressure balance valve item 19 execution only without clogging indicator or clogging sensor EHD 61 01E.60 dimension EHD 91 01E.90 22 x 3,5 56 x 3 63 x 2,6 x 1 45 x 3 49,7 x 2,4 x 1 38 x 3 28 x 3 8x2 G¾ G¼ AOR or AOC AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 20913-4 article-no. EHD 151 01E.150 304341 (NBR) 305072 (NBR) 304392 (FPM) 305322 (FPM) 312309 304991 (NBR) 304997 (FPM) 317709 304340 (NBR) 316778 (NBR) 310004 (NBR) 317013 (FPM) 318366 (FPM) 316530 (FPM) 313815 306968 see sheet-no. 1606 see sheet-no. 1615 see sheet-no. 1617 see sheet-no. 1618 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 314442 5. Description: Duplex pressure filters with change-over valve type EHD are suitable for a working pressure up to 315 bar. The pressure peaks are absorbed by a sufficient margin of safety. Duplex filters can be serviced without interruption of operation. The upper part has a three-way-change-over valve which allows to change-over the flow from the dirty filter-side to the clean filter-side without interrupting the operation. The change-over procedure does not lead to a cross sectional contraction. Prior to the change-over procedure a built-in pressure balance valve equalizes the housing pressure. After change-over the pressure balance valve is to be closed again. The closed filter-side has to be air-bled by vent V respectively by vent VI. Then change filter element. After screw in the filter bowl the pressure balance has to be opened shortly and the just serviced filter-side has to be air-bled. Filter elements are available down to a filter fineness of 4 µm(c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available with a pressure difference resistance up to ∆p 160 bar and a rupture strength up to ∆p 250 bar. The internal valves are integrated into the centering pivot for the filter element. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter. With the reverse valve a protection of the filter element is given when having a reverse flow inside the filter. The reverse flow will not be filtered. 6. Technical data: temperature range: -10°C to +80°C (for a short time +100°C) operating medium: mineral oil, other media on request max. operating pressure: 315 bar test pressure: 410 bar connection system: thread connection according to ISO 228 housing material: DIN 17440 - 1.4571 (320 S 18, 320 S 31 according to B.S.) sealing material: Nitrile (NBR) or Viton (FPM), other materials on request installation position: vertical air bleeding and mini-measuring connections dirt side: G¼ measuring connections clean side: G¾ Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). 7. Symbols: without indicator with electrical indicator AE 30 and AE 40 with visual- electrical indicator AE 50 and AE 62 with visual- electrical indicator AE 70 and AE 80 with visual indicator AOR/AOC with electronical clogging sensor VS1 with electronical clogging sensor VS2 filter without internal valve filter with by-pass valve filter with reversing valve 8. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’ respectively ∆p-curves ; depending on filter fineness and viscos ity. 9. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 E 2530 E Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration p erformance STAINLESS STEEL- PRESSURE FILTER, Series Sheet No. change-over 2533 D EHD 241 - 451 DN 40 PN 315 1. Type index: 1.1. Complete filter: (ordering example) EHD. 241. 10VG. HR. E. P. VA. FS. 7. VA. -. AE 1 2 3 4 5 6 7 8 9 10 11 12 1 series: EHD = stainless steel-pressure filter, change-over 2 nominal size: 241, 451 3 filter-material and filter-fineness: 80G = 80 µm, 40G = 40 µm, 25G = 25 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) resistance of pressure difference for filter element: 30 = ∆p 30 bar HR = ∆p 160 bar (rupture strength ∆p 250 bar) 4 5 filter element design: E = single-end open 6 sealing material: P = Nitrile (NBR) V = Viton (FPM) 7 filter element specification: (see catalog) = standard VA = stainless steel IS06 = see sheet-no. 31601 8 connection: FS = SAE-flange connection 6000 PSI 9 connection size: 7 = 1 ½“ 10 filter housing specification: VA = stainless steel 11 internal valve: = without S1 = with by-pass valve ∆p 3,5 bar S2 = with by-pass valve ∆p 7,0 bar R = reversing valve, Q ≤ 211,008 l/min 12 clogging indicator or clogging sensor : = without AOR = visual, see sheet-no. 1606 AOC = visual, see sheet-no. 1606 AE = visual-electrical, see sheet-no. 1615 VS1 = electronical, see sheet-no. 1617 VS2 = electronical, see sheet-no. 1618 1.2. Filter element: (ordering example) 01E. 240. 10VG. HR. E. P. VA 1 2 3 4 5 6 7 1 series: 01E. = filter element according to INTERNORMEN factory specification 2 nominal size: 240, 450 3 - 7 see type index-complete filter 2. Accessories: Pos. I: left filter-side in operation Pos. II: right filter-side in operation - Connection III and IV to be used to bleed filter or to relieve pressure. measure- and bleeder connection, see sheet-no. 1650 3. Dimensions: type EHD 241 EHD 451 connection SAE 1 ½“ A 398 583 B 340 525 weight kg 102 116 volume tank 2x 0,85 l 2x 1,55 l Changes of measures and design are subject to alteration! EDV 11/07 Friedensstrasse 41, 68804 Altlussheim, Germany phone fax +49 - (0)6205 - 2094-0 +49 - (0)6205 - 2094-40 e-mail url sales@internormen.com www.internormen.com 4. Spare parts: item qty. designation dimension 1 2 filter element 2 2 O-ring 3 2 O-ring 4 2 support ring 5 3 O-ring 6 2 sliding ring 7 4 O-ring 8 4 O-ring 9 4 O-ring 10 4 screw plug 11 1 clogging indicator visual 12 1 clogging indicator visual-electrical 13 1 clogging sensor electronical 14 1 clogging sensor electronical 15 1 O-ring 16 1 O-ring 17 1 O-ring 18 1 screw plug 19 1 pressure balance valve 20 4 screw plug item 18 execution only without clogging indicator or clogging sensor EHD 241 01E. 240 article-no. EHD 451 01E. 450 34 x 3,5 76 x 4 84 x 3,2 x 1,5 70 x 4 076 x70 x 45° 56 x 3 42,52 x 2,62 10 x 2 G¼ AOR or AOC AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 20913-4 nominal size 10 G1 304338 (NBR) 305599 (NBR) 304730 (FPM) 310291 (FPM) 312307 306253 (NBR) 310280 (FPM) 318070 305072 (NBR) 304352 (NBR) 309998 (NBR) 305322 (FPM) 304393 (FPM) 310272 (FPM) 306968 see sheet-no. 1606 see sheet-no. 1615 see sheet-no. 1617 see sheet-no. 1618 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 314442 310316 308498 5. Description: Duplex pressure filters with change-over valve type EHD are suitable for a working pressure up to 315 bar. The pressure peaks are absorbed by a sufficient margin of safety. Duplex filters can be serviced without interruption of operation. The upper part has a three-way-change-over valve which allows to change-over the flow from the dirty filter-side to the clean filterside without interrupting the operation. The change-over procedure does not lead to a cross sectional contraction. Prior to the change-over procedure a built-in pressure balance valve equalizes the housing pressure. After change-over the pressure balance valve has to to be closed again. The closed filter-side has to be air-bled by vent III respectively by vent IV. Then change filter element. After screw in the filter bowl the pressure balance has to be opened shortly and the just serviced filter-side has to be airbled. Filter elements are available down to a filter fineness of 4 µm(c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt-retaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available with a pressure difference resistance up to ∆p 160 bar and a rupture strength up to ∆p 250 bar. The internal valves are integrated into the centering pivot for the filter element. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter. With the reverse valve a protection of the filter element is given when having a reverse flow inside the filter. The reverse flow will not be filtered. 6. Technical data: temperature range: -10°C to +80°C (for a short time +100°C) operating medium: mineral oil, other media on request max. operating pressure: 315 bar test pressure: 450 bar connection system: SAE-flange connection 6000 PSI housing material: EN10088 - 1.4571 (320 S 18, 320 S 31 according to B.S.) sealing material: Nitrile (NBR) or Viton (FPM), other materials on request installation position: vertical air bleeding and mini-measuring connection: G¼ Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). 7. Symbols: without indicator with electrical indicator AE 30 and AE 40 with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with visual indicator AOR/AOC with electronical clogging sensor VS1 with electronical clogging sensor VS2 filter without internal valve filter with by-pass valve filter with reversing valve 8. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p-curves; depending on filter fineness and viscosity. 9. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 Verification of collapse/burst resistance ISO 2942 Verification of fabrication integrity ISO 2943 Verification of material compatibility with fluids ISO 3723 Method for end load test ISO 3724 Verification of flow fatigue characteristics ISO 3968 Evaluation of pressure drop versus flow characteristics ISO 16889 Multi-pass method for evaluating filtration performance E 2533 D STAINLESS STEEL-PRESSURE FILTER, change-over Series EDU 251-401 DN 50 PN 25 Sheet No. 2124 H 1. Type index: 1.1. Complete filter: (ordering example) EDU. 251. 10VG. 30. E. P. VA. FS. 8. VA. AE 1 1 2 3 4 5 6 7 8 9 10 11 2 3 4 5 6 7 8 9 10 11 series: EDU = stainless steel-pressure fi lter, change-over nominal size: 251, 401 filter-material and filter-fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm stainless steel wire mesh, 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass f ibre) resistance of pressure difference for filter element: 30 = ∆p 30 bar filter element design: E = single-end open S = with by-pass valve ∆p 2,0 bar S1 = with by-pass valve ∆p 3,5 bar sealing material: P = Nitrile (NBR) V = Viton (FPM) filter element specification: (see catalog) = standard VA = stainless steel IS06 = see sheet-no.31601 connection: FS = SAE-flange connection 3000 PSI connection size: 8 = 2 ‘’ filter housing specification: VA = stainless steel clogging indicator or clogging sensor: = without AE = visual-electrical, see sheet-no. 1609 OP = visual, see sheet-no. 1628 OE = visual-electrical, see sheet-no. 1628 VS1 = electronical, see sheet-no. 1607 VS2 = electronical, see sheet-no. 1608 1.2. Filter element: (ordering example) 01NL. 250. 10VG. 30. E. P. VA 1 1 2 3 4 5 6 7 2 series: 01NL. = standard filter element according to DIN 24550, T3 nominal size: 250, 400 3 - 7 see type index-complete filter 2. Accessories: Pos. I: Pos. II: left filter-side in ope ration right filter-side in operation - measure- and bleeder-connections, see sheet-no. 1650 - evacuation- and bleeder-connections, see sheet-no. 1651 - counter flange, see sheet-no. 1652 - shut-off valve, see sheet-no. 1655 weight EDU 251: approx. 40 kg weight EDU 401: approx. 50 kg Changes of measures and design are subject to alteration! EDV 11/07 Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax +49 - (0)6205 - 2094-40 url www.internormen.com 3. Spare parts: item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 designation filter element O-ring O-ring O-ring O-ring O-ring O-ring screw plug screw plug clogging indicator, visual clogging indicator, visual-electrical clogging indicator, visual-electrical clogging sensor, electronical clogging sensor, electronical O-ring screw plug pressure balance valve 6. Symbols: qty. 2 2 2 1 2 1 1 8 2 1 1 1 1 1 2 2 1 dimension EDU 251 01NL. 250...VA 115 x 3 G½ qty. 2 40 x 3 4 24 x 3 95 x 3 76 x 4 32 x 2,5 10 G¼ OP OE AE VS1 VS2 14 x 2 G¼ dimension EDU 401 01NL. 400...VA 115 x 3 G½ article-no. 304389 (NBR) 304391 (FPM) 303963 (NBR) 307762 (FPM) 303038 (NBR) 304397 (FPM) 305808 (NBR) 304828 (FPM) 305599 (NBR) 310291 (FPM) 306843 (NBR) 308268 (FPM) 306966 306968 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 304342 (NBR) 304722 (FPM) 306968 without indicator with electrical indicator AE 30 and AE 40 with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with visual indicator OP with visual-electrical indicator OE with electronical clogging sensor VS1 with electronical clogging sensor VS2 item 16 execution only without clogging indicator or clogging sensor 4. Description: Stainless steel-pressure filter of the series EDU 251-401 are suitable for a working pressure up to 25 bar. The pressure peaks are absorbed by a sufficient margin of safety. Rotary slide valve which is integrated in the middle of the housing makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. These filters can be installed as suction-filters. The filter element consist of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside. Filter finer than 40 µm should use throw-away elements made of Interpor fleece (glass fibre). Filter elements as fine as 5 µm (c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt-retaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. Approvals according to TÜV, and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. 5. Technical data: temperature range: operating medium: max. operating pressure: test pressure: connection system: housing material: sealing material: installation position: mini-measuring connections: evacuation-or bleeder connections: volume tank EDU 251: EDU 401: 7. Pressure drop flow curves: - 10°C to + 80°C (for a short time + 100°C) mineral oil, other media on request 25 bar 32,5 bar SAE-flange connection 3000 PSI DIN 17445 -1.4581 (318 C 17, ANC 4 C according to B.S.) Nitrile (NBR) or Viton (FPM), other materials on request vertical G¼ G½ 2x 2,5 l 2x 3,7 l Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). E 2124 H 8. Test methods: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. Filter elements are tested according to the following ISO standards: ISO 2941 Verification of collapse/burst resistance ISO 2942 Verification of fabrication integrity ISO 2943 Verification of material compatibility with fluids ISO 3723 Method for end load test ISO 3724 Verification of flow fatigue characteristics ISO 3968 Evaluation of pressure drop versus flow charact eristics ISO 16889 Multi-pass method for evaluating filtration perfo rmance STAINLESS STEEL-PRESSURE FILTER, change-over Series EDU 635 DN 65 Sheet No. PN 25 2150 A 1. Type index: 1.1. Complete filter: (ordering example) EDU. 635. 10VG. 30. E. P. VA. FS. 9. VA. -. AE 1 1 2 3 4 5 6 7 8 9 10 11 12 2 3 4 5 6 7 8 9 10 11 12 series: EDU = stainless steel-pressure filter, cha nge-over nominal size: 635 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm stainless steel wire mesh, 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 30 = ∆p 30 bar filter element design: E = single-end open S = with by-pass valve ∆p 2,0 bar S1 = with by-pass valve ∆p 3,5 bar sealing material: P = Nitrile (NBR) V = Viton (FPM) filter element specification: (see catalog) = standard VA = stainless steel IS06 = see sheet-no. 31601 IS07 = see sheet-no. 31602 connection: FS = SAE-flange connection 3000 PSI connection size: 9 = 2½“ filter housing specification: VA = stainless steel internal valve: = without clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 1.2. Filter element: (ordering example) 01NL. 630. 10VG. 30. E. P. VA 1 1 2 3 4 5 6 7 2 series: 01NL. = standard filter element according to DIN 24550, T3 nominal size: 630 3 - 7 see type index-complete filter 2. Accessories: - measure- and bleeder connections, see sheet-no. 1650 - evacuation and bleeder-conections, see sheet-no. 1651 - counter flanges, see sheet-no. 1652 - shut-off valve, see sheet-no. 1655 weight: approx. 90 kg Changes of measures and design are subject to alteration! Pos. I: left filter-side in operation Pos. II: lright filter-side in operation EDV 11/07 Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax +49 - (0)6205 - 2094-40 url www.internormen.com 6. Symbols: 3. Spare parts: item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 qty. 2 2 2 4 4 4 2 2 2 4 8 1 1 1 1 1 1 1 1 2 2 1 designation filter element O-ring O-ring O-ring O-ring gasket screw plug O-ring O-ring O-ring screw plug clogging indicator, visual clogging indicator, visual clogging indicator, visual-electrical clogging indicator, visual-electrical clogging sensor, electronical clogging sensor, electronical O-ring O-ring O-ring screw plug pressure balance valve dimension 01NL. 630...VA 60 x 3,5 125 x 3 85 x 4 95 x 3 G¼ 32 x 3 69,45 x 3,53 8x2 G½ AOR oder AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x2 G¼ article-no. 304377 (NBR) 304398 (FPM) 306025 (NBR) 307358 (FPM) 305685 (NBR) 310285 (FPM) 305808 (NBR) 304828 (FPM) 317651 306968 304368 (NBR) 311020 (FPM) 305868 (NBR) 307357 (FPM) 310004 (NBR) 316530 (FPM) 306966 see sheet no. 1606 see sheet no. 1628 see sheet no. 1628 see sheet no. 1609 see sheet no. 1607 see sheet no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 without indicator with electrical indicator AE 30 and AE 40 with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with visual indicator AOR/AOC/OP with visual-electrical indicator OE with electronical clogging sensor VS1 with electronical clogging sensor VS2 item 21 execution only without clogging indicator or clogging sensor 4. Description: Stainless steel-pressure filters, change-over series EDU 635 are suitable for operating pressure up to 25 bar. Pressure peaks can be absorbed with a sufficient margin of safety. Change-over ball valve between the two filter housings makes it possible to switch from the dirty filter-side to the clean filter-side without interruting operation. The filter element consist of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside. These filters can be installed as suct ion filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 mµ should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. Approvals according to TÜV, and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p-curves; depending on filter fin eness and viscosity. 5. Technical data: temperature range: operating medium: max. operating pressure: test pressure: connection system: housing material: switching housing-material: sealing material: installation position: mini-measuring connections: evacuation-or bleeder connections: volume tank: - 10°C to + 80°C (for a short time + 100°C) mineral oil, other media on request 25 bar 32,5 bar SAE-flange connection 3000 PSI DIN17445 - 1.4581(318 C 17, ANC 4 C according to B.S.) DIN17440 - 1.4541(320 S18, 320 S31 according to B.S.) Nitrile (NBR) or Viton (FPM), other materials on request vertical G¼ G½ 2x 5,7 l Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). E 2150 A 8. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrit y Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration performance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 101 NPS 1“ CLASS 150 PSI 2168 B 1. Type index: 1.1. Complete filter: (ordering example) EDA. 101. 10VG. 30. E. P. VA. FS. 5. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. Position I: Position II: Filter 1 in operation Filter 2 in operation 15 16 2 5 6 7 8 9 10 11 12 13 14 15 16 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 30 = ∆p 30 bar filter element design: E = single-end open, S = with by-pass valve ∆p 2,0 bar, S1 = with by-pass valve ∆p 3,5 bar sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA11 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA12 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 16 µm FD1 = flange connection DIN EN 1092-1, design B1 FD2 = flange connection DIN EN 1092-1, design B2 process connection size: 5 = 1“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1 Changes of measures and design are subject to alterat ion! 4 1.2. Filter element: (ordering example) 01NL. 100. 10VG. 30. E. P. VA 1 EDV 05/10 3 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 101 2 3 4 5 6 7 2 series: 01NL. = standard filter element according to DIN 24550, T3 nominal size: 100 3 - 7 see type index complete filter weight: approx. 60 kg Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 2. Accessories: 6. Symbols: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 150 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 1659 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 3. Spare parts: item qty. designation 1 2 filter element 2 1 change over UKK 3 2 O-ring 4 6 O-ring 5 6 screw plug 6 1 clogging indicator, visual 7 1 clogging indicator, visual-electrical 8 1 clogging indicator, visual-electrical 9 1 clogging indicator, visual-electrical 10 1 clogging sensor, electronical 11 1 clogging sensor, electronical 12 1 O-ring 13 1 O-ring 14 2 O-ring 15 2 screw plug 16 1 pressure balance valve 17 2 O-ring (only for execution with ANSI/DIN-flange) item 15 execution only with clogging indicator or clogging sensor dimension 01NL.100... DN 25 22 x 3,5 54 x 3 NPT ½ AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 32,9 x 3,53 article-no. 304341 (NBR) 304392 (FPM) 304657 (NBR) 304720 (FPM) 307766 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 318850 (NBR) 338231(FPM) 4. Description: Stainless steel-pressure filters, change-over series EDA 101 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ NPT ½“ NPT ½“ 2x 0,9 l according to B16.5 CLASS 150 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2168 B with visual-electrical indicator OE 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: 5. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank : operating pressure adapter flanges: with visual indicator AOR/AOC/OP ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 100 NPS 1“ CLASS 300 PSI 2159 C 1. Type index: 1.1. Complete filter: (ordering example) EDA. 100. 10VG. 30. E. P. VA. FS. 5. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 12 13 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. Position I: Position II: Filter 1 in operation Filter 2 in operation 14 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 100 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 30 = ∆p 30 bar filter element design: E = single-end open, S = with by-pass valve ∆p 2,0 bar, S1 = with by-pass valve ∆p 3,5 bar sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA1 = ANSI-flange connection CLASS 300 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA2 = ANSI-flange connection CLASS 300 PSI, sealing surface R z = 16 µm FD41 = flange connection DIN EN 1092-1, design B1 FD42 = flange connection DIN EN 1092-1, design B2 process connection size: 5 = 1“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NL. 100. 10VG. 30. E. P. VA 1 1 EDV 05/10 Changes of measures and design are subject to alterat ion! 2 3 4 5 6 7 2 series: 01NL. = standard filter element according to DIN 24550, T3 nominal size: 100 3 - 7 see type index complete filter weight: approx. 60 kg Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 2. Accessories: 6. Symbols: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 300 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 1659 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 3. Spare parts: item qty. designation 1 2 filter element 2 1 change over UKK 3 2 O-ring 4 6 O-ring 5 6 screw plug 6 1 clogging indicator, visual 7 1 clogging indicator, visual-electrical 8 1 clogging indicator, visual-electrical 9 1 clogging indicator, visual-electrical 10 1 clogging sensor, electronical 11 1 clogging sensor, electronical 12 1 O-ring 13 1 O-ring 14 2 O-ring 15 2 screw plug 16 1 pressure balance valve 17 2 O-ring (only for execution with ANSI/DIN-flange) item 15 execution only with clogging indicator or clogging sensor dimension 01NL.100... DN 25 22 x 3,5 54 x 3 NPT ½ AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 32,9 x 3,53 article-no. 304341 (NBR) 304392 (FPM) 304657 (NBR) 304720 (FPM) 307766 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 318850 (NBR) 338231(FPM) 4. Description: Stainless steel-pressure filters, change-over series EDA 100 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ NPT ½“ NPT ½“ 2x 0,9 l according to B16.5 CLASS 300 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2159 C with visual-electrical indicator OE 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: 5. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank : operating pressure adapter flanges: with visual indicator AOR/AOC/OP ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 251-401 NPS 2“ CLASS 150 PSI Sheet No. 2169 B 1. Type index: 1.1. Complete filter: (ordering example) EDA. 401. 10VG. 30. E. P. VA. FS. 8. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. 12 13 Position I: Position II: Filter 1 in operation Filter 2 in operation 14 15 16 2. Dimensions: type EDA 251 EDA 401 EDV 05/10 connection SAE 2“ ANSI 2“ DIN EN 2“ ANSI 1 ½“ DIN EN 1 ½“ SAE 2“ ANSI 2“ DIN EN 2“ ANSI 1 ½“ DIN EN 1 ½“ A B C D 455 398 260 365 595 538 410 475 E 180 162 179 159 180 162 179 159 weight kg 2 3 4 5 6 7 8 9 10 11 12 13 14 15 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 251, 401 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 30 = ∆p 30 bar filter element design: E = single-end open, S = with by-pass valve ∆p 2,0 bar, S1 = with by-pass valve ∆p 3,5 bar sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA11 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA12 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 16 µm FD1 = flange connection DIN EN 1092-1, design B1 FD2 = flange connection DIN EN 1092-1, design B2 process connection size: 7 = 1 ½“ (only with adapter), 8 = 2“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NL. 400. 10VG. 30. E. P. VA 1 ca. 130 1 2 3 4 5 6 7 2 series: 01NL. = standard filter element according to DIN 24550, T3 nominal size: 250, 400 3 - 7 see type index complete filter ca. 160 Changes of measures and design are subject to alteration! Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 16 7. Symbols: 3. Accessories: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 150 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 1659 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 4. Spare parts: item qty. designation 1 2 filter element 2 1 change over UKK 3 2 O-ring 4 6 O-ring 5 8 O-ring 6 6 screw plug 7 2 mini-measuring connection 8 1 clogging indicator, visual 9 1 clogging indicator, visual-electrical 10 1 clogging indicator, visual-electrical 11 1 clogging indicator, visual-electrical 12 1 clogging sensor, electronical 13 1 clogging sensor, electronical 14 1 O-ring 15 1 O-ring 16 2 O-ring 17 2 screw plug 18 1 pressure balance valve 19 2 O-ring (only for execution with ANSI/DIN-flange) item 17 execution only with clogging indicator or clogging sensor dimension EDA 251 EDA 401 01NL. 250... 01NL. 400... DN 50 40 x 3 100 x 5 56 x 3 NPT ½ MA.1.VA AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 56,75 x 3,53 article-no. 304389NBR) 305482FPM) 327063 (NBR) 327064 (FPM) 305072 (NBR) 305322 (FPM) 307766 320128 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 306035 (NBR) 310264 (FPM) with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 with visual indicator AOR/AOC/OP with visual-electrical indicator OE 5. Description: Stainless steel-pressure filters, change-over series EDA 251-401 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. 8. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 9. Test methods: Filter elements are tested according to the following ISO standards: 6. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank EDA 251: EDA 401: operating pressure adapter flanges: - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ 2x 3,0 l 2x 4,3 l according to B16.5 CLASS 150 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2169 B ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 250-400 NPS 2“ CLASS 300 PSI Sheet No. 2157 C 1. Type index: 1.1. Complete filter: (ordering example) EDA. 400. 10VG. 30. E. P. VA. FS. 8. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. 12 13 Position I: Position II: Filter 1 in operation Filter 2 in operation 14 15 16 2. Dimensions: type EDA 250 EDA 400 EDV 05/10 connection SAE 2“ ANSI 2“ DIN EN 2“ ANSI 1 ½“ DIN EN 1 ½“ SAE 2“ ANSI 2“ DIN EN 2“ ANSI 1 ½“ DIN EN 1 ½“ A B C D 455 398 260 365 595 538 410 475 E 187 165 185 162 187 165 185 162 weight kg 2 3 4 5 6 7 8 9 10 11 12 13 14 15 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 250, 400 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 30 = ∆p 30 bar filter element design: E = single-end open, S = with by-pass valve ∆p 2,0 bar, S1 = with by-pass valve ∆p 3,5 bar sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA1 = ANSI-flange connection CLASS 300 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA2 = ANSI-flange connection CLASS 300 PSI, sealing surface R z = 16 µm FD41 = flange connection DIN EN 1092-1, design B1 FD42 = flange connection DIN EN 1092-1, design B2 process connection size: 7 = 1 ½“ (only with adapter), 8 = 2“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NL. 400. 10VG. 30. E. P. VA 1 ca. 130 1 2 3 4 5 6 7 2 series: 01NL. = standard filter element according to DIN 24550, T3 nominal size: 250, 400 3 - 7 see type index complete filter ca. 160 Changes of measures and design are subject to alteration! Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 16 7. Symbols: 3. Accessories: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 300 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 1659 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 4. Spare parts: item qty. designation 1 2 filter element 2 1 change over UKK 3 2 O-ring 4 6 O-ring 5 8 O-ring 6 6 screw plug 7 2 mini-measuring connection 8 1 clogging indicator, visual 9 1 clogging indicator, visual-electrical 10 1 clogging indicator, visual-electrical 11 1 clogging indicator, visual-electrical 12 1 clogging sensor, electronical 13 1 clogging sensor, electronical 14 1 O-ring 15 1 O-ring 16 2 O-ring 17 2 screw plug 18 1 pressure balance valve 19 2 O-ring (only for execution with ANSI/DIN-flange) item 17 execution only with clogging indicator or clogging sensor dimension EDA 250 EDA 400 01NL. 250... 01NL. 400... DN 50 40 x 3 100 x 5 56 x 3 NPT ½ MA.1.VA AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 56,75 x 3,53 article-no. 304389NBR) 305482FPM) 327063 (NBR) 327064 (FPM) 305072 (NBR) 305322 (FPM) 307766 320128 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 306035 (NBR) 310264 (FPM) with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 with visual indicator AOR/AOC/OP with visual-electrical indicator OE 5. Description: Stainless steel-pressure filters, change-over series EDA 250-400 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. 8. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 9. Test methods: Filter elements are tested according to the following ISO standards: 6. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank EDA 251: EDA 401: operating pressure adapter flanges: - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ 2x 3,0 l 2x 4,3 l according to B16.5 CLASS 300 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2157 C ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 631-1001 NPS 3“ CLASS 150 PSI 2170 B 1. Type index: 1.1. Complete filter: (ordering example) EDA. 1001. 10VG. 30. E. P. VA. FS. A. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 12 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. Position I: Position II: Filter 1 in operation Filter 2 in operation 13 14 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 631, 1001 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 30 = ∆p 30 bar filter element design: E = single-end open, S = with by-pass valve ∆p 2,0 bar, S1 = with by-pass valve ∆p 3,5 bar sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA11 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA12 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 16 µm FD1 = flange connection DIN EN 1092-1, design B1 FD2 = flange connection DIN EN 1092-1, design B2 process connection size: A = 3“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent , see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NL. 1000. 10VG. 30. E. P. VA 1 2. Dimensions: type EDA 631 EDA 1001 EDV 05/10 connection SAE 3“ SAE 3“ 1 A 687 917 B 631 861 C 410 640 D 604 834 weight kg approx. 290 approx. 350 Changes of measures and design are subject to alteration! 2 3 4 5 6 7 2 series: 01NL. = standard filter element according to DIN 24550, T3 nominal size: 630, 1000 3 - 7 see type index complete filter Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 16 7. Symbols: 3. Accessories: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 150 PSI, see sheet-no. 165 8 - drain- and bleeder connection, see sheet-no. 1659 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 4. Spare parts: item qty. designation 1 2 filter element 2 1 change over UKK 3 2 O-ring 4 4 O-ring 5 2 O-ring 6 6 screw plug 7 2 mini-measuring connection 8 1 clogging indicator, visual 9 1 clogging indicator, visual-electrical 10 1 clogging indicator, visual-electrical 11 1 clogging indicator, visual-electrical 12 1 clogging sensor, electronical 13 1 clogging sensor, electronical 14 1 O-ring 15 1 O-ring 16 2 O-ring 17 2 screw plug 18 1 pressure balance valve 19 2 O-ring (only for execution with ANSI/DIN-flange) item 17 execution only with clogging indicator or clogging sensor dimension EDA 631 EDA 1001 01NL.630 01NL.1000 DN 80 60 x 3,5 135 x 4,75 136,12 x 3,53 NPT ½ MA.1.VA AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 85,32 x 3,53 article-no. 304377 (NBR) 304398 (FPM) 326348 (NBR) 326349 (FPM) 320162 (NBR) 320163 (FPM) 307766 320128 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 305590 (NBR) 306308 (FPM) 5. Description: Stainless steel-pressure filters, change-over series EDA 631-1001 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI 2x 8,3 l 2x 11,8 l according to B16.5 CLASS 150 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2170 B with visual-electrical indicator OE 8. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 9. Test methods: Filter elements are tested according to the following ISO standards: 6. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank EDA 631: EDA 1001: operating pressure adapter flanges: with visual indicator AOR/AOC/OP ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 630-1000 NPS 3“ CLASS 300 PSI 2158 C 1. Type index: 1.1. Complete filter: (ordering example) EDA. 1000. 10VG. 30. E. P. VA. FS. A. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 12 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. Position I: Position II: Filter 1 in operation Filter 2 in operation 13 14 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 630, 1000 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 30 = ∆p 30 bar filter element design: E = single-end open, S = with by-pass valve ∆p 2,0 bar, S1 = with by-pass valve ∆p 3,5 bar sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA1 = ANSI-flange connection CLASS 300 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA2 = ANSI-flange connection CLASS 300 PSI, sealing surface R z = 16 µm FD41 = flange connection DIN EN 1092-1, design B1 FD42 = flange connection DIN EN 1092-1, design B2 process connection size: A = 3“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NL. 1000. 10VG. 30. E. P. VA 1 2. Dimensions: type EDA 630 EDA 1000 EDV 05/10 connection SAE 3“ SAE 3“ 1 A 687 917 B 631 861 C 410 640 D 604 834 weight kg approx. 290 approx. 350 Changes of measures and design are subject to alteration! 2 3 4 5 6 7 2 series: 01NL. = standard filter element according to DIN 24550, T3 nominal size: 630, 1000 3 - 7 see type index complete filter Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 16 7. Symbols: 3. Accessories: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 300 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 1659 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 4. Spare parts: item qty. designation 1 2 filter element 2 1 change over UKK 3 2 O-ring 4 4 O-ring 5 2 O-ring 6 6 screw plug 7 2 mini-measuring connection 8 1 clogging indicator, visual 9 1 clogging indicator, visual-electrical 10 1 clogging indicator, visual-electrical 11 1 clogging indicator, visual-electrical 12 1 clogging sensor, electronical 13 1 clogging sensor, electronical 14 1 O-ring 15 1 O-ring 16 2 O-ring 17 2 screw plug 18 1 pressure balance valve 19 2 O-ring (only for execution with ANSI/DIN-flange) item 17 execution only with clogging indicator or clogging sensor dimension EDA 630 EDA 1000 01NL.630 01NL.1000 DN 80 60 x 3,5 135 x 4,75 136,12 x 3,53 NPT ½ MA.1.VA AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 85,32 x 3,53 article-no. 304377 (NBR) 304398 (FPM) 326348 (NBR) 326349 (FPM) 320162 (NBR) 320163 (FPM) 307766 320128 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 305590 (NBR) 306308 (FPM) 5. Description: Stainless steel-pressure filters, change-over series EDA 630-1000 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI 2x 8,3 l 2x 11,8 l according to B16.5 CLASS 300 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2158 C with visual-electrical indicator OE 8. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 9. Test methods: Filter elements are tested according to the following ISO standards: 6. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank EDA 630: EDA 1000: operating pressure adapter flanges: with visual indicator AOR/AOC/OP ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 1004 NPS 3“ CLASS 300 PSI 2176 A 1. Type index: 1.1. Complete filter: (ordering example) EDA. 1004. 10VG. 10. B. P. VA. FS. A. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 12 13 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. Position I: Position II: 14 Filter 1 in operation Filter 2 in operation 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 1004 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 10 = ∆p 10 bar filter element design: B = both sides open sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA1 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA2 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 16 µm FD41 = flange connection DIN EN 1092-1, design B1 FD42 = flange connection DIN EN 1092-1, design B2 process connection size: A = 3“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without, S1 = with by-pass valve ∆p 3,5 bar clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NR. 1000. 10VG. 10. B. P. VA 1 1 EDV 05/10 Changes of measures and design are subject to alteration! 2 3 4 5 6 7 2 series: 01NL. = standard-return-line filter element according to DIN 24550, T4 nominal size: 1000 3 - 7 see type index complete filter weight: approx. 370 kg Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 6. Symbols: 2. Accessories: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 300 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 1659 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 3. Spare parts: item qty. designation 1 2 filter element 2 1 change over UKK 3 4 O-ring 4 2 O-ring 5 2 circlip 6 4 O-ring 7 2 O-ring 8 12 screw plug 9 2 mini-measuring connection 10 1 clogging indicator, visual 11 1 clogging indicator, visual-electrical 12 1 clogging indicator, visual-electrical 13 1 clogging indicator, visual-electrical 14 1 clogging sensor, electronical 15 1 clogging sensor, electronical 16 1 O-ring 17 1 O-ring 18 2 O-ring 19 2 screw plug 20 1 pressure balance valve 21 2 O-ring (only for execution with ANSI/DIN-flange) item 19 execution only with clogging indicator or clogging sensor dimension 01NR.1000 ... DN 80 90 x 4 62 x 4 DIN472-75x2,5-1.4310 200 x 4 185 x 6 NPT ½ MA.1.VA AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 85,32 x 3,53 article-no. 306941 (NBR) 307031 (FPM) 308045 (NBR) 311472 (FPM) 318481 334555 (NBR) 334554 (FPM) 335381 (NBR) 335306 (FPM) 307766 320128 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 305590 (NBR) 306308 (FPM) with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 with visual indicator AOR/AOC/OP with visual-electrical indicator OE 4. Description: Stainless steel-pressure filters, change-over series EDA 1004 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: 5. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank : operating pressure adapter flanges: - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ 2x 19 l according to B16.5 CLASS 300 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2176 A ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 1005 NPS 4“ CLASS 300 PSI 2177 A 1. Type index: 1.1. Complete filter: (ordering example) EDA. 1005. 10VG. 10. B. P. VA. FS. B. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 12 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. Position I: Position II: Filter 1 in operation Filter 2 in operation 13 14 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 1005 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 10 = ∆p 10 bar filter element design: B = both sides open sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA1 = ANSI-flange connection CLASS 300 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA2 = ANSI-flange connection CLASS 300 PSI, sealing surface R z = 16 µm FD41 = flange connection DIN EN 1092-1, design B1 FD42 = flange connection DIN EN 1092-1, design B2 process connection size: B = 4“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without, S1 = with by-pass valve ∆p 3,5 bar clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NR. 1000. 10VG. 10. B. P. VA 1 1 EDV 05/10 Changes of measures and design are subject to alteration! 2 3 4 5 6 7 2 series: 01NL. = standard-return-line filter element according to DIN 24550, T4 nominal size: 1000 3 - 7 see type index complete filter weight: approx. 415 kg Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 6. Symbols: 2. Accessories: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 300 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 1659 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 3. Spare parts: item qty. designation 1 2 filter element 2 1 change over UKK 3 4 O-ring 4 2 O-ring 5 2 circlip 6 4 O-ring 7 2 O-ring 8 12 screw plug 9 2 mini-measuring connection 10 1 clogging indicator, visual 11 1 clogging indicator, visual-electrical 12 1 clogging indicator, visual-electrical 13 1 clogging indicator, visual-electrical 14 1 clogging sensor, electronical 15 1 clogging sensor, electronical 16 1 O-ring 17 1 O-ring 18 2 O-ring 19 2 screw plug 20 1 pressure balance valve 21 2 O-ring (only for execution with ANSI/DIN-flange) item 19 execution only with clogging indicator or clogging sensor dimension 01NR.1000 ... DN 100 90 x 4 62 x 4 DIN472-75x2,5-1.4310 200 x 4 185 x 6 NPT ½ MA.1.VA AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 110,72 x 3,53 article-no. 306941 (NBR) 307031 (FPM) 308045 (NBR) 311472 (FPM) 318481 334555 (NBR) 334554 (FPM) 335381 (NBR) 335306 (FPM) 307766 320128 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 316355 (NBR) 316356 (FPM) with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 with visual indicator AOR/AOC/OP with visual-electrical indicator OE 4. Description: Stainless steel-pressure filters, change-over series EDA 1005 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: 5. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank : operating pressure adapter flanges: - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ 2x 19 l according to B16.5 CLASS 300 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2177 A ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 1014 NPS 3“ CLASS 150 PSI 2175 A 1. Type index: 1.1. Complete filter: (ordering example) EDA. 1014. 10VG. 10. B. P. VA. FS. A. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 12 13 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. Position I: Position II: 14 Filter 1 in operation Filter 2 in operation 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 1014 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 10 = ∆p 10 bar filter element design: B = both sides open sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA11 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA12 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 16 µm FD1 = flange connection DIN EN 1092-1, design B1 FD2 = flange connection DIN EN 1092-1, design B2 process connection size: A = 3“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without, S1 = with by-pass valve ∆p 3,5 bar clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NR. 1000. 10VG. 10. B. P. VA 1 1 EDV 05/10 Changes of measures and design are subject to alteration! 2 3 4 5 6 7 2 series: 01NL. = standard-return-line filter element according to DIN 24550, T4 nominal size: 1000 3 - 7 see type index complete filter weight: approx. 370 kg Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 6. Symbols: 2. Accessories: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 150 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 1659 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 3. Spare parts: item qty. designation 1 2 filter element 2 1 change over UKK 3 4 O-ring 4 2 O-ring 5 2 circlip 6 4 O-ring 7 2 O-ring 8 12 screw plug 9 2 mini-measuring connection 10 1 clogging indicator, visual 11 1 clogging indicator, visual-electrical 12 1 clogging indicator, visual-electrical 13 1 clogging indicator, visual-electrical 14 1 clogging sensor, electronical 15 1 clogging sensor, electronical 16 1 O-ring 17 1 O-ring 18 2 O-ring 19 2 screw plug 20 1 pressure balance valve 21 2 O-ring (only for execution with ANSI/DIN-flange) item 19 execution only with clogging indicator or clogging sensor dimension 01NR.1000 ... DN 80 90 x 4 62 x 4 DIN472-75x2,5-1.4310 200 x 4 185 x 6 NPT ½ MA.1.VA AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 85,32 x 3,53 article-no. 306941 (NBR) 307031 (FPM) 308045 (NBR) 311472 (FPM) 318481 334555 (NBR) 334554 (FPM) 335381 (NBR) 335306 (FPM) 307766 320128 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 305590 (NBR) 306308 (FPM) with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 with visual indicator AOR/AOC/OP with visual-electrical indicator OE 4. Description: Stainless steel-pressure filters, change-over series EDA 1014 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: 5. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank : operating pressure adapter flanges: - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ 2x 19 l according to B16.5 CLASS 150 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2175 A ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 1015 NPS 4“ CLASS 150 PSI 2171 A 1. Type index: 1.1. Complete filter: (ordering example) EDA. 1015. 10VG. 10. B. P. VA. FS. B. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. Position I: Position II: Filter 1 in operation Filter 2 in operation 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 1015 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 10 = ∆p 10 bar filter element design: B = both sides open sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA11 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA12 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 16 µm FD1 = flange connection DIN EN 1092-1, design B1 FD2 = flange connection DIN EN 1092-1, design B2 process connection size: B = 4“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without, S1 = with by-pass valve ∆p 3,5 bar clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NR. 1000. 10VG. 10. B. P. VA 1 1 EDV 05/10 Changes of measures and design are subject to alteration! 2 3 4 5 6 7 2 series: 01NL. = standard-return-line filter element according to DIN 24550, T4 nominal size: 1000 3 - 7 see type index complete filter weight: approx. 415 kg Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 6. Symbols: 2. Accessories: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 150 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 1659 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 3. Spare parts: item qty. designation 1 2 filter element 2 1 change over UKK 3 4 O-ring 4 2 O-ring 5 2 circlip 6 4 O-ring 7 2 O-ring 8 12 screw plug 9 2 mini-measuring connection 10 1 clogging indicator, visual 11 1 clogging indicator, visual-electrical 12 1 clogging indicator, visual-electrical 13 1 clogging indicator, visual-electrical 14 1 clogging sensor, electronical 15 1 clogging sensor, electronical 16 1 O-ring 17 1 O-ring 18 2 O-ring 19 2 screw plug 20 1 pressure balance valve 21 2 O-ring (only for execution with ANSI/DIN-flange) item 19 execution only with clogging indicator or clogging sensor dimension 01NR.1000 ... DN 100 90 x 4 62 x 4 DIN472-75x2,5-1.4310 200 x 4 185 x 6 NPT ½ MA.1.VA AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 110,72 x 3,53 article-no. 306941 (NBR) 307031 (FPM) 308045 (NBR) 311472 (FPM) 318481 334555 (NBR) 334554 (FPM) 335381 (NBR) 335306 (FPM) 307766 320128 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 316355 (NBR) 316356 (FPM) with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 with visual indicator AOR/AOC/OP with visual-electrical indicator OE 4. Description: Stainless steel-pressure filters, change-over series EDA 1015 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: 5. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank : operating pressure adapter flanges: - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ 2x 19 l according to B16.5 CLASS 150 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2171 A ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 2204 NPS 3“ CLASS 300 PSI 2179 1. Type index: 1.1. Complete filter: (ordering example) EDA. 2204. 10VG. 10. B. P. VA. FS. A. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. Position I: Position II: Filter 1 in operation Filter 2 in operation 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 2204 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 10 = ∆p 10 bar filter element design: B = both sides open sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA1 = ANSI-flange connection CLASS 300 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA2 = ANSI-flange connection CLASS 300 PSI, sealing surface R z = 16 µm FD41 = flange connection DIN EN 1092-1, design B1 FD42 = flange connection DIN EN 1092-1, design B2 process connection size: A = 3“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without, S1 = with by-pass valve ∆p 3,5 bar clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NR. 1000. 10VG. 10. B. P. VA 1 1 EDV 05/10 Changes of measures and design are subject to alteration! 2 3 4 5 6 7 2 series: 01NL. = standard-return-line filter element according to DIN 24550, T4 nominal size: 1000 3 - 7 see type index complete filter weight: approx. 490 kg Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 6. Symbols: 2. Accessories: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 300 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 1659 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 3. Spare parts: item qty. designation 1 4 filter element 2 1 change over UKK 3 8 O-ring 4 2 O-ring 5 2 circlip 6 4 O-ring 7 2 O-ring 8 12 screw plug 9 2 mini-measuring connection 10 1 clogging indicator, visual 11 1 clogging indicator, visual-electrical 12 1 clogging indicator, visual-electrical 13 1 clogging indicator, visual-electrical 14 1 clogging sensor, electronical 15 1 clogging sensor, electronical 16 1 O-ring 17 1 O-ring 18 2 O-ring 19 2 screw plug 20 1 pressure balance valve 21 2 O-ring (only for execution with ANSI/DIN-flange) item 19 execution only with clogging indicator or clogging sensor dimension 01NR.1000 ... DN 80 90 x 4 62 x 4 DIN472-75x2,5-1.4310 200 x 4 185 x 6 NPT ½ MA.1.VA AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 85,32 x 3,53 article-no. 306941 (NBR) 307031 (FPM) 308045 (NBR) 311472 (FPM) 318481 334555 (NBR) 334554 (FPM) 335381 (NBR) 335306 (FPM) 307766 320128 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 305590 (NBR) 306308 (FPM) with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 with visual indicator AOR/AOC/OP with visual-electrical indicator OE 4. Description: Stainless steel-pressure filters, change-over series EDA 2204 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: 5. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank : operating pressure adapter flanges: - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ 2x 30 l according to B16.5 CLASS 300 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2179 ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 2205 NPS 4“ CLASS 300 PSI 2178 A 1. Type index: 1.1. Complete filter: (ordering example) EDA. 2205. 10VG. 10. B. P. VA. FS. B. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. Position I: Position II: Filter 1 in operation Filter 2 in operation 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 2205 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 10 = ∆p 10 bar filter element design: B = both sides open sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA1 = ANSI-flange connection CLASS 300 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA2 = ANSI-flange connection CLASS 300 PSI, sealing surface R z = 16 µm FD41 = flange connection DIN EN 1092-1, design B1 FD42 = flange connection DIN EN 1092-1, design B2 process connection size: B = 4“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without, S1 = with by-pass valve ∆p 3,5 bar clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NR. 1000. 10VG. 10. B. P. VA 1 1 EDV 05/10 Changes of measures and design are subject to alteration! 2 3 4 5 6 7 2 series: 01NL. = standard-return-line filter element according to DIN 24550, T4 nominal size: 1000 3 - 7 see type index complete filter weight: approx. 500 kg Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 6. Symbols: 2. Accessories: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 300 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 165 9 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 3. Spare parts: item qty. designation 1 4 filter element 2 1 change over UKK 3 8 O-ring 4 2 O-ring 5 2 circlip 6 4 O-ring 7 2 O-ring 8 12 screw plug 9 2 mini-measuring connection 10 1 clogging indicator, visual 11 1 clogging indicator, visual-electrical 12 1 clogging indicator, visual-electrical 13 1 clogging indicator, visual-electrical 14 1 clogging sensor, electronical 15 1 clogging sensor, electronical 16 1 O-ring 17 1 O-ring 18 2 O-ring 19 2 screw plug 20 1 pressure balance valve 21 2 O-ring (only for execution with ANSI/DIN-flange) item 19 execution only with clogging indicator or clogging sensor dimension 01NR.1000 ... DN 100 90 x 4 62 x 4 DIN472-75x2,5-1.4310 200 x 4 185 x 6 NPT ½ MA.1.VA AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 110,72 x 3,53 article-no. 306941 (NBR) 307031 (FPM) 308045 (NBR) 311472 (FPM) 318481 334555 (NBR) 334554 (FPM) 335381 (NBR) 335306 (FPM) 307766 320128 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 316355 (NBR) 316356 (FPM) with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 with visual indicator AOR/AOC/OP with visual-electrical indicator OE 4. Description: Stainless steel-pressure filters, change-over series EDA 2205 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: 5. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank : operating pressure adapter flanges: - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ 2x 30 l according to B16.5 CLASS 300 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2178 A ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 2214 NPS 3“ CLASS 150 PSI 2167 1. Type index: 1.1. Complete filter: (ordering example) EDA. 2214. 10VG. 10. B. P. VA. FS. A. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. Position I: Position II: Filter 1 in operation Filter 2 in operation 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 2214 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 10 = ∆p 10 bar filter element design: B = both sides open sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA11 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA12 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 16 µm FD1 = flange connection DIN EN 1092-1, design B1 FD2 = flange connection DIN EN 1092-1, design B2 process connection size: A = 3“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without, S1 = with by-pass valve ∆p 3,5 bar clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NR. 1000. 10VG. 10. B. P. VA 1 1 EDV 05/10 Changes of measures and design are subject to alteration! 2 3 4 5 6 7 2 series: 01NL. = standard-return-line filter element according to DIN 24550, T4 nominal size: 1000 3 - 7 see type index complete filter weight: approx. 490 kg Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 6. Symbols: 2. Accessories: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 150 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 1659 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 3. Spare parts: item qty. designation 1 4 filter element 2 1 change over UKK 3 8 O-ring 4 2 O-ring 5 2 circlip 6 4 O-ring 7 2 O-ring 8 12 screw plug 9 2 mini-measuring connection 10 1 clogging indicator, visual 11 1 clogging indicator, visual-electrical 12 1 clogging indicator, visual-electrical 13 1 clogging indicator, visual-electrical 14 1 clogging sensor, electronical 15 1 clogging sensor, electronical 16 1 O-ring 17 1 O-ring 18 2 O-ring 19 2 screw plug 20 1 pressure balance valve 21 2 O-ring (only for execution with ANSI/DIN-flange) item 19 execution only with clogging indicator or clogging sensor dimension 01NR.1000 ... DN 80 90 x 4 62 x 4 DIN472-75x2,5-1.4310 200 x 4 185 x 6 NPT ½ MA.1.VA AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 85,32 x 3,53 article-no. 306941 (NBR) 307031 (FPM) 308045 (NBR) 311472 (FPM) 318481 334555 (NBR) 334554 (FPM) 335381 (NBR) 335306 (FPM) 307766 320128 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 305590 (NBR) 306308 (FPM) with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 with visual indicator AOR/AOC/OP with visual-electrical indicator OE 4. Description: Stainless steel-pressure filters, change-over series EDA 2214 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: 5. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank : operating pressure adapter flanges: - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ 2x 30 l according to B16.5 CLASS 150 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2167 ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance Sheet No. STAINLESS STEEL-PRESSURE FILTER, change-over Series EDA 2215 NPS 4“ CLASS 150 PSI 2172 B 1. Type index: 1.1. Complete filter: (ordering example) EDA. 2215. 10VG. 10. B. P. VA. FS. B. IS30. -. AE. AV. IS21. F. F 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1) Connection for the potential equalisation at inlet and outlet, only for application in the explosive area. Position I: Position II: Filter 1 in operation Filter 2 in operation 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 series: EDA = stainless steel-pressure filter change-over, according to ASME-code nominal size: 2215 filter-material and filter- fineness: 80 G = 80 µm, 40 G = 40 µm, 25 G = 25 µm, 10 G = 10 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 25 API = 20 µm, 10 API = 10 µm Interpor fleece (glass fibre) according to API 25 P = 25 µm, 10 P = 10 µm paper resistance of pressure difference for filter element: 10 = ∆p 10 bar filter element design: B = both sides open sealing material: P = Nitrile (NBR), V = Viton (FPM) filter element specification: = standard, VA = stainless steel process connection: FS = SAE-flange connection 3000 PSI FA11 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 160 µm (not finer than 40 µm) FA12 = ANSI-flange connection CLASS 150 PSI, sealing surface R z = 16 µm FD1 = flange connection DIN EN 1092-1, design B1 FD2 = flange connection DIN EN 1092-1, design B2 process connection size: B = 4“ filter housing specification: (material) see sheet-no. 55050 = standard, per according to specification pressure vessel DGLR/ASME, 1.4571/type 304-316L IS30 = only type 316, see sheet-no. 55219 internal valve: = without, S1 = with by-pass valve ∆p 3,5 bar clogging indicator or clogging sensor: = without, OP = visual, see sheet-no. 1628 AOR = visual, see sheet-no. 1606, OE = visual-electrical, see sheet-no. 1628 AOC = visual, see sheet-no. 1606, VS1 = electronical, see sheet-no. 1607 AE = visual-electrical, see sheet-no. 1609, VS2 = electronical, see sheet-no. 1608 shut-off valve: = without, AV = shut-off valve, see sheet-no. 1655 specification pressure vessel: = standard (PED 97/23/EC) IS20 = ASME VIII Div.1 with ASME equivalent material, see sheet-no. 55217 IS21 = ASME VIII Div.1 with U-stamp, see sheet-no. 43415 IS23 = ASME VIII Div.1 without U-stamp, see sheet-no. 55218 switch lever: F = toward IN/OUT, B = opposite IN/OUT air bleeding/drain: F = toward IN/OUT, B = opposite IN/OUT 1.2. Filter element: (ordering example) 01NR. 1000. 10VG. 10. B. P. VA 1 1 EDV 05/10 Changes of measures and design are subject to alteration! 2 3 4 5 6 7 2 series: 01NL. = standard-return-line filter element according to DIN 24550, T4 nominal size: 1000 3 - 7 see type index complete filter weight: approx. 500 kg Friedensstrasse 41, 68804 Altlussheim, Germany phone +49 - (0)6205 - 2094-0 e-mail sales@internormen.com fax url www.internormen.com +49 - (0)6205 - 2094-40 6. Symbols: 2. Accessories: - SAE-counter flanges, see sheet-no. 1652 - adapter for connection acc. to EN1092-1, see sheet-no. 1657 - adapter for ANSI-connection B16.5 CLASS 150 PSI, see sheet-no. 1658 - drain- and bleeder connection, see sheet-no. 165 9 without indicator with shut-off valve with by-pass valve with electrical indicator AE 30 and AE 40 3. Spare parts: item qty. designation 1 4 filter element 2 1 change over UKK 3 8 O-ring 4 2 O-ring 5 2 circlip 6 4 O-ring 7 2 O-ring 8 12 screw plug 9 2 mini-measuring connection 10 1 clogging indicator, visual 11 1 clogging indicator, visual-electrical 12 1 clogging indicator, visual-electrical 13 1 clogging indicator, visual-electrical 14 1 clogging sensor, electronical 15 1 clogging sensor, electronical 16 1 O-ring 17 1 O-ring 18 2 O-ring 19 2 screw plug 20 1 pressure balance valve 21 2 O-ring (only for execution with ANSI/DIN-flange) item 19 execution only with clogging indicator or clogging sensor dimension 01NR.1000 ... DN 100 90 x 4 62 x 4 DIN472-75x2,5-1.4310 200 x 4 185 x 6 NPT ½ MA.1.VA AOR or AOC OP OE AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 G¼ DN 10 110,72 x 3,53 article-no. 306941 (NBR) 307031 (FPM) 308045 (NBR) 311472 (FPM) 318481 334555 (NBR) 334554 (FPM) 335381 (NBR) 335306 (FPM) 307766 320128 see sheet-no. 1606 see sheet-no. 1628 see sheet-no. 1628 see sheet-no. 1609 see sheet-no. 1607 see sheet-no. 1608 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 306968 310316 316355 (NBR) 316356 (FPM) with visual-electrical indicator AE 50 and AE 62 with visual-electrical indicator AE 70 and AE 80 with electronical sensor VS1 with electronical sensor VS2 with visual indicator AOR/AOC/OP with visual-electrical indicator OE 4. Description: Stainless steel-pressure filters, change-over series EDA 2215 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order. 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p- curves; depending on filter fin eness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: 5. Technical data: temperature ranges - calculation temperature (pressure vessel): - medium temperature: - ambient temperature: - survival temperature: operating medium: max. operating pressure: test pressure acc. to PED 97/23/EC: test pressure acc. to ASME VIII Div. 1: test pressure acc. to API 614, Chapter 1: connection system: housing material: sealing material: installation position: bleeder connection : drain connection dirt side : drain connection clean side : volume tank : operating pressure adapter flanges: - 10°C to +100°C - 10°C to +80°C - 40°C to +60°C - 40°C to +100°C (short-time) mineral oil, other media on request 40 bar 1,43 x operating pressure = 57 bar 1,3 x operating pressure = 52 bar 1,5 x operating pressure = 60 bar SAE-flange connection 3000 PSI stainless steel, see sheet-no. 55050 Nitrile (NBR) or Viton (FPM), other materials on request vertical NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ and SAE ¾“ 3000 PSI NPT ½“ 2x 30 l according to B16.5 CLASS 150 PSI / DIN EN 1092-1 Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4) E 2172 B ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration perfo rmance Sheet No. STAINLESS STEEL- PRESSURE FILTER Series EHPF 60-150 DN 18 1440 PN 315 1. Type index: 1.1. Complete filter: (ordering example) EHPF. 90. 10VG. HR. E. P. VA. F. 4. VA. -. AE 1 1 2 3 4 5 6 7 8 9 10 11 12 series: EHPF = stainless steel-pressure filter, manifold mounted nominal size: 60, 90, 150 2 3 filter-material and filter-fineness: 80G = 80 µm, 40G = 40 µm, 25G = 25 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) 4 resistance of pressure difference for filter element: 30 = ∆p 30 bar HR = ∆p 160 bar (rupture strength ∆p 250 bar) 5 filter element design: E = single-end open 6 sealing material: P = Nitrile (NBR) V = Viton (FPM) 7 filter element specification: (see catalog) = standard VA = stainless steel IS06 see sheet-no. 31601 8 connection: F = manifold mounted 9 connection size: 4 = DN 18 10 filter housing specification: VA = stainless steel 11 internal valve: = without S1 = with by-pass valve ∆p 3,5 bar S2 = with by-pass valve ∆p 7,0 bar R = reversing valve, Q ≤ 70,06 l/min 12 clogging indicator or clogging sensor : = without AOR = visual, see sheet-no. 1606 AOC = visual, see sheet-no. 1606 AE = visual-electrical, see sheet-no. 1615 VS1 = electronical, see sheet-no. 1617 VS2 = electronical, see sheet-no. 1618 1.2. Filter element: (ordering example) 01E. 90. 10VG. HR. E. P. VA 1 1 2 3 4 5 6 7 2 series: 01E. = filter element according to INTERNORMEN factory specification nominal size: 60, 90, 150 3 - 7 see type index-complete filter 2. Dimensions: type EHPF 60 EHPF 90 EHPF 150 connection DN 18 A 213 278 388 B 215 280 390 weight kg 10 11 13 volume tank 0,3 l 0,4 l 0,6 l Changes of measures and design are subject to alteration! EDV 10/08 Friedensstrasse 41, 68804 Altlussheim, Germany phone fax +49 - (0)6205 - 2094-0 +49 - (0)6205 - 2094-40 e-mail url sales@internormen.com www.internormen.com 3. Spare parts: item qty. 1 2 3 4 5 6 7 8 9 10 11 12 13 1 1 1 1 2 1 1 1 1 1 1 1 1 designation EHPF60 01E.60 filer element O-ring O-ring support ring O-ring clogging indicator, visual clogging indicator, visual-electrical clogging sensor, electronical clogging sensor, electronical O-ring O-ring O-ring screw plug dimension EHPF 90 EHPF 150 01E.90 01E.150 22 x 3,5 56 x 3 63 x 2,6 x 1 22 x 3 AOR or AOC AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 40171-4 article-no. 304341 (NBR) 305072 (NBR) 304392 (FPM) 305322 (FPM) 312309 304387 (NBR) 304931 (FPM) see sheet no. 1606 see sheet no. 1615 see sheet no. 1617 see sheet no. 1618 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 314442 item 13 execution only without clogging indicator or clogging sensor 4. Description: The stainless steel pressure filters of the series EHPF are suitable for a working pressure up to 315 bar. The pressure peaks are absorbed by a sufficient margin of safety. The EHPF-filters are flanged to the mounting-surface. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to inside. Filter elements are available down to a filter fineness of 4µm (c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt-retaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available up to a pressure difference resistance of ∆p 160 bar and a rupture strength of ∆p 250 bar. The internal valves are integrated into the centering pivot for the filter element. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter. With the reverse valve a protection of the filter element is given when having a reverse flow inside the filter. The reverse flow will not be filtered. 5. Technical data: temperature range: operating medium: max. operating pressure: test pressure: connection system: housing material: sealing material: installation position: - 10°C to +80°C (for a short time +100°C) mineral oil, other media on request 315 bar 450 bar manifold mounted EN10088 - 1.4571 (320 S 18, 320 S 31 according to B.S.) Nitrile (NBR) or Viton (FPM), other materials on request vertical Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). 6. Symbols: without indicator with electrical indicator AE 30 and AE 40 with visual-electrical indicator AE 50 and AE 62 with visualelectrical indicator AE 70 and AE 80 with visual indicator AOR/AOC with electronical clogging sensor VS1 with electronical clogging sensor VS2 filter without internal valve filter with by-pass valve filter with reversing valve 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p-curves; depending on filter fineness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 E 1440 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration performance Sheet No. STAINLESS STEEL- PRESSURE FILTER Series EHPF 170 - 450 DN 28 1441 PN 315 1. Type index: 1.1. Complete filter: (ordering example) EHPF. 360. 10VG. HR. E. P. VA. F. 5. VA. -. AE 1 2 3 4 5 6 7 8 9 10 11 12 1 series: EHPF 2 nominal size: 170, 240, 360, 450 3 filter-material and filter-fineness: 80G = 80 µm, 40G = 40 µm, 25G = 25 µm stainless steel wire mesh 25 VG = 20 µm(c), 16 VG = 15 µm(c), 10 VG = 10 µm(c), 6 VG = 7 µm(c), 3 VG = 5 µm(c) Interpor fleece (glass fibre) resistance of pressure difference for filter element: 30 = ∆p 30 bar HR = ∆p 160 bar (rupture strength ∆p 250 bar) 4 = stainless steel-pressure filter, manifold mouted 5 filter element design: E = single-end open 6 sealing material: P = Nitrile (NBR) V = Viton (FPM) 7 filter element specification: (see catalog) = standard VA = stainless steel IS06 see sheet-no. 31601 8 connection: F = manifold mounted 9 connection size: 5 = DN 28 10 filter housing specification: VA = stainless steel 11 internal valve: = without S1 = with by-pass valve ∆p 3,5 bar S2 = with by-pass valve ∆p 7,0 bar R = reversing valve, Q ≤ 211,008 l/min 12 clogging indicator or clogging sensor : = without AOR = visual, see sheet-no. 1606 AOC = visual, see sheet-no. 1606 AE = visual-electrical, see sheet-no. 1615 VS1 = electronical, see sheet-no. 1617 VS2 = electronical, see sheet-no. 1618 1.2. Filter element: (ordering example) 01E. 360.10VG. HR. E. P. VA 1 1 2 3 4 5 6 7 series: 01E. = filter element according to INTERNORMEN factory specification 2 nominal size: 170, 240, 360, 450 3 - 7 see type index-complete filter 2. Dimensions: type EHPF 170 EHPF 240 EHPF 360 EHPF 450 connection DN 28 A 333 383 463 568 B 330 380 460 565 weight kg 22 24 26 30 volume tank 0,7 l 0,9 l 1,2 l 1,6 l Changes of measures and design are subject to alteration! EDV 10/08 Friedensstrasse 41, 68804 Altlussheim, Germany phone fax +49 - (0)6205 - 2094-0 +49 - (0)6205 - 2094-40 e-mail url sales@internormen.com www.internormen.com 3. Spare parts: item qty. 1 2 3 4 5 6 7 8 9 10 11 12 13 1 1 1 1 2 1 1 1 1 1 1 1 1 designation EHPF 170 01E.170 filter element O-ring O-ring support ring O-ring clogging indicator, visual clogging indicator, visual-electrical clogging sensor, electronical clogging sensor, electronical O-ring O-ring O-ring screw plug dimensions EHPF 240 EHPF 360 01E.240 01E.360 34 x 3,5 76 x 4 84 x 3,2 x 1,5 32 x 3 AOR or AOC AE VS1 VS2 15 x 1,5 22 x 2 14 x 2 40171-4 article-no. EHPF 450 01E.450 304338 (NBR) 305599 (NBR) 304730 (FPM) 310291 (FPM) 312307 304368 (NBR) 311020 (FPM) see sheet-no. 1606 see sheet-no. 1615 see sheet-no. 1617 see sheet-no. 1618 315357 (NBR) 315427 (FPM) 304708 (NBR) 304721 (FPM) 304342 (NBR) 304722 (FPM) 314442 item 13 execution only without clogging indicator or clogging sensor 4. Description: The stainless steel-pressure filters of the series EHPF are suitable for a working pressure up to 315 bar. The pressure peaks are absorbed by a sufficient margin of safety. The EHPF-filters are flanged to the mounting-surface. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to inside. Filter elements are available down to a filter fineness of 4µm (c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt-retaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available up to a pressure difference resistance of ∆p 160 bar and a rupture strength of ∆p 250 bar. The internal valves are integrated into the centering pivot for the filter element. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter. With the reverse valve a protection of the filter element is given when having a reverse flow inside the filter. The reverse flow will not be filtered. 5. Technical data: temperature range: operating medium: max. operating pressure: test pressure: connection system: housing material: sealing material: installation position: -10°C to +80°C (for a short time +100°C) mineral oil, other media on request 315 bar 450 bar manifold mounted EN10088-1.4571 (320 S 18, 320 S 31 according to B.S.) Nitrile (NBR) or Viton (FPM), other materials on request vertical Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). 6. Symbols: without indicator with electrical indicator AE 30 and AE 40 with visual-electrical indicator AE 50 and AE 62 with visualelectrical indicator AE 70 and AE 80 with visual indicator AOR/AOC with electronical clogging sensor VS1 with electronical clogging sensor VS2 filter without internal valve filter with by-pass valve filter with reversing valve 7. Pressure drop flow curves: Precise flow rates see ‘INT-Expert-System Filter’, respectively ∆p-curves; depending on filter fineness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 ISO 2942 ISO 2943 ISO 3723 ISO 3724 ISO 3968 ISO 16889 E 1441 Verification of collapse/burst resistance Verification of fabrication integrity Verification of material compatibility with fluids Method for end load test Verification of flow fatigue characteristics Evaluation of pressure drop versus flow characteristics Multi-pass method for evaluating filtration performance
Similar documents
PRESSURE FILTER, manifold mounted
Precise flow rates see ‘INT-Expert-System Filter’ respectively ∆p-curves ; depending on filter fineness and viscosity.
More information