Time-delay relays from riese
Transcription
Time-delay relays from riese
Time-delay relays from riese • Clock-pulsed • Flashing • Multifunction • On-delay • Interval time-delay • Off-delay Applications Relay designations Column On-delay RS-VR1, RS-VR2, RS-ZR1, RS-ZR2, RS-ER1, RS-ER2, RS-ERF, RS-LR1,RS-LR2, RS-LZ1, RS-LZ2, RS-LZF 1 2, 3 4, 5, 6, 7 Category according to EN 13849-1 1 1 1 1 1 1 1 Off-delay RS-AR1, RS-AR2, RS-AZ1, RS-AZ2, RS-LA1, RS-LA2, RS-AZS 8, 9 10, 11 1 1 1 1 Flashing RS-BR1, RS-BR2, RS-BRS1, RS-BRS2 12, 13 1 1 Clock-pulsed RS-TG1, RS-TG2, RS-TGI1, RS-TGI2 14, 15 1 1 Multifunction RS-MF 16 1 Interval time-delay RS-EI1, RS-EI2, RS-EIF, RS-WAR 17, 18, 19 1 1 1 Technical specifications Voltage drift +/- 0.001 % / % ∆U (CMOS technology) +/- 0.2 % / % ∆U (transistor technology) +/- 0.02 % / ∆°C (CMOS technology) +/- 0.15 % / ∆°C (transistor technology) 1 change-over contact: 10A (RS-SD,SDS: 8A) 2 change-over contacts: 5A each other switching current / switching capacity on enquiry 10g N/O contact 1.5g N/C contact in all 3 directions, approx. 32 Hz DIN VDE 0110-1, DIN EN 50178, degree of pollution 2, category of overvoltage 3 Terminals and housings to DIN VDE 0470-1, housings IP 50, terminals IP 20. Finger-touch and back-of-hand-touch protection to VDE 0106/100 as well as VBG4. Temperature drift Max. continuous current Shock/Vibration resistance Leakage paths / Air gaps Class of protection Dimensions see drawing + Repeat accuracy + Setting accuracy at end of scale (tolerance) Voltage tolerance range Frequency (AC-type) Max. switching voltage Mechanical life Ambient temperature Test voltage Mounting dimensions +/- 4%, /- 10%, /- 20% depending on device 0.85 - 1.1 x UB 50…60 Hz 250 V AC, 50..60 Hz, 30 V DC relay 6 at least 5x10 operations -25°C to +70°C 2500 V, 50 Hz to DIN EN 60715 Power consumption Duty cycle Max. switching rate Contact material Climatic resistance More Standards Weight Conductor Terminal markings to DIN EN 50005 Operating position +/- 0.5 % (CMOS technology) +/- 2.0 % (transistor technology) < 7,5 VA 100 % continuous 6000 operations/h hard silver or equivalent material to DIN 40040, class F to DIN VDE 0435 approx. 120 g 2x1.5 mm² solid or 2x1.0 mm² stranded with ferrules no restriction Visual switching state (green) and voltage supply (red); Initiator connection triggered via contact or 2-wire-proximity switch with residual current < 5mA. Not available for the following types: RS-VR1, RS-VR2, RS-AZ1, RS-AZ2, RS-LA1, RS-LA2, RS-AZS, RS-MF, RS-SD, RS-SDS. We reserve the right to make changes to the technical specification. We were taking great care making up the texts and drawings. Nevertheless failures cannot be eliminated completely. Release 2011 Puls schedule for RS-MF: Dimensions 22.5mm housing: 8-terminal 22.5 housing 12-terminal housing 99 22.5 Function EWI Voltag supply concact on off closed open Relayscontact closed open 35mm rails 75 80 80 Instantaneous tv Function TI Voltag supply on off Relayscontact closed open tv Outstanding quality We not just test our relays after they are finished, we even test them at every step of production! Our testing strategy thoroughly checks all functions of every single relay by means of a computerized testing system which we have developed ourselves. We simulate situations in which the bad cases happen all at once. Only after such testing a relay gets the "OK". Therefore, "riese-relays" are ideally situated to rough environments, e.g. severe vibrations, temperature fluctuations or voltage discrepancies. We are certified according to: ISO 9001:2008 and ISO/TS 16949:2009 (automotive standard) All products have a CE label. Product features: Connection terminals in standard terminal position. Captive plus/minus screws. Class of protection to DIN EN 50102, IP 20. Finger-touch and back-of-hand-touch protection to VDE 0106/100 as well as BGVA2 (VBG 4). Conductors to DIN EN 40050. Initiator connection (if available). Visual switching state and voltage supply indication by means of LED (not on RS-VR, RS-AZS). With EAN-Nr. (European Article Number) Mounting on standard 35mm rails to DIN 46 277 by means of snap-on fixings. Self-extinguishing housing material to UL 94-V1. Class of protection to DIN VDE 0470-1, IP 50. Wireless design. Special features 1. 12 V relays, e.g. for vehicles, vehicle mountings We have developed a number of relays especially for this purpose. Not all types are included in this leaflet so please call us for details. 2. 24 V relays, e.g. for railways, tram systems. Peculiar to railways and tram systems is the fact that the voltage changes depending on the number of vehicles. We have managed to overcome these and other specific problems. 3. Brandlabelling Do you need relays with your company logo? No problem! Your serial number and bar code your logo A1 B1 12 14 B2 B1 B3 A2 B2 B3 product name 11 Level Relay 2 MOhm U = 24VAC 50-60Hz K = 2 changer 22 24 your logo 5 A, 250VAC company 123 Main Street Anytown, ST 12345 company-name.com 21 min max 4. Special designs If you can't find the relay you're looking for in our range, then please contact our design department. We relish the opportunity to discover new ways of optimizing your applications. Who or what is riese electronic? • • • • • Since 1958, riese electronic develops assemblies, purchases materials worldwide, produces in SMT and THT and tests electronic devices according to customers' requirements. 1979: "Most innovative middle-sized company of the year 1979", Award by “manager magazine” and the german bank. Time-delay, control- and measuring relays bearing the "riese" name are available since 1987, safety relays since 1991. 2006 Adjustment of the business into two divisions 1. Automation & Safety (A&S) 2. Electronic Manufacturing Service (EMS) 2008 Official opening of the new building in Langenwolschendorf/ Thuringia. Riese electronic has 100 employees at its two sites in Horb, Baden-Wuerttemberg and Langenwolschendorf, Thuringia. Timerelay On-delay Type Function/ Contact Pulse schedule/ Function diagram RS-VR1, RS-VR2 RS-ZR1, RS-ZR2 RS-ER1, RS-ER2 RS-ERF RS-LR1, RS-LR2 RS-LZ1, RS-LZ2 RS-LZF On-delay 1 changer contact (RS-VR1) 2 changer contacts(RS-VR2) On-delay 1 changer contact (RS-ZR1) 2 changer contacts(RS-ZR2) On-delay 1 changer contact (RS-ER1) 2 changer contacts(RS-ER2) On-delay 1 changer contact and remote connection On-delay 1 changer contact (RS-LR1) 2 changer contacts(RS-LR2) On-delay 1 changer contact (RS-LZ1) 2 changer contacts (RS-LZ2) On-delay 1 changer contact and remote connection Voltage On supply Off Voltage On supply Off Voltage On supply Off Voltage On supply Off Voltage On supply Off Voltage On supply Off Voltage On supply Off tv Output closed relay open tv Output closed relay open tv Output closed relay open tv Output closed relay open tv Output closed relay open tv Output closed relay open All devices up to category 1 according to EN 13849-1 tv Output closed relay open Wiring diagram 15 A1 15 A1 15 A1 A2 16 18 A1 18 16 A2 18 16 A2 RS-VR1 LED Timing ranges Exciting voltage Tolerances 25 16 18 2628 28 A2 RS-VR2 No 0.05 0.15 0.5 1.5 3 5 15 30 15 A1 15 A1 15 A1 A2 16 18 A1 26 25 15 18 16 A2 RS-ZR1 A2 16 18 26 28 28 A2 RS-ZR2 12 24 42-48 110-127 230 1s 3s 10 s 30 s 60 s 100 s 300 s 600 s V AC/DC V AC/DC V AC V AC V AC 10% 0.05 0.15 0.5 1.5 3 5 15 30 - 12 24 42-48 110-127 230 15 A1 15 A1 15 A1 A2 16 18 A1 25 18 16 2 LEDs - 26 25 15 18 16 A2 RS-ER1 V AC/DC V AC/DC V AC V AC V AC 10% 0.05 0.15 0.5 1.5 3 5 15 30 A1 Z1 25 A2 16 18 26 28 18 16 28 A2 - 12 24 42-48 110-127 230 15 Z2 15 A1 Z1 A2 Z2 16 18 18 16 A2 RS-ERF RS-ER2 2 LEDs 1s 3s 10 s 30 s 60 s 100 s 300 s 600 s 26 25 15 V AC/DC V AC/DC V AC V AC V AC 4% 0.05 0.15 0.5 1.5 3 5 15 30 - 24 42-48 110-127 230 15 A1 15 A2 1618 18 16 A1 15 A1 A2 18 16 A2 RS-LR1 2 LEDs 1s 3s 10 s 30 s 60 s 100 s 300 s 600 s A1 RS-LR2 2 LEDs 1s 3s 10 s 30 s 60 s 100 s 300 s 600 s V AC/DC V AC V AC V AC 4% 1.5 3 0.15 0.5 26 25 15 16 18 26 28 28 A2 15 A1 15 A1 15 A1 A2 1618 A1 25 18 16 A2 30 min 60 min 3h 10 h 12 24 42-48 110-127 230 V AC/DC V AC/DC V AC V AC V AC 10% 15 Z2 A1 Z1 25 A2 16 18 26 28 28 A2 A1 Z1 15 A2 Z2 16 18 18 16 RS-LZ2 RS-LZ1 1.5 3 0.15 0.5 26 25 15 18 16 2 LEDs - A2 2 LEDs - 30 min 60 min 3h 10 h 12 24 42-48 110-127 230 V AC/DC V AC/DC V AC V AC V AC 4% 1.5 3 0.15 0.5 - 30 min 60 min 3h 10 h 12 24 42-48 110-127 230 V AC/DC V AC/DC V AC V AC V AC 4% CMOS technology Analog time setting Absolute scale CMOS technology Analog time setting Absolute scale CMOS technology Analog time setting Absolute scale CMOS technology Analog time setting Absolute scale CMOS technology Analog time setting Absolute scale CMOS technology Analog time setting Absolute scale Description of function The time lag begins after applying the exciting voltage to terminals A1 und A2. The output relay remains in its normal position. After the time has expired, the output relay attracts and remains in this switched position until the exciting voltage is interrupted. If the exciting voltage is interrupted, the output relay returns to its normal position. Pulse control shorter than reset time does not lead to the output relay switching through instantaneously. see col. 1 see col. 1 Resistance value for all time ranges is 10 kΩ. The factory fitted jumper is to be removed upon connecting an external potentiometer for setting the time. The remote potentiometer is to be connected to terminals Z1 and Z2. The internal potentiometer is to be set to the shortest time. The lines to the external potentiometer can be up to 100 m long. Note: there is no electrical isolation between terminals Z1 and Z2 and the exciting voltage A1 and A2. see col. 1 see col. 1 see col. 4 2 3 4 5 6 Are you missing a time range or do you need a fixed time? There are special customizing solutions riese-electronic is able to offer. Fo more information and questions you will find our contact address on the back of this leaflet. Time-relays of riese- electronic also operate with 12 V. Voltage tolerance up to +/-30% CMOS technology Analog time setting Absolute scale 1 Our devices accord to VDE 0116 (regulation for combustion plants)! RS-LZF Attributes Column Specials and extras for you Are you interested in "brandlabel" relays? Your and our free range for future ideas and developments. You would like to have your corporate symbol on safety-, time-delay-, or measuring- relays you are purchasing? Do you have certain housing forms you want to apply? We are able to provide you with many years of experience due to our customizing division. We are capable to meet your needs flexibly at any time. Let us know about your requirements. Whether there shall be only your logo on the relay, or also a certain colour or housing is demanded, we will create a complete brandlabelproject to develop, produce and test your specific relay, quick and with competence. 7 23 Timerelay Off-delay Type Function/ Contact Pulse schedule/ Function diagram RS-AR1, RS-AR2 RS-AZ1, RS-AZ2 RS-LA1, RS-LA2 RS-AZS Off-delay without auxiliary voltage 1 changer contact (RS-AR1) 2 changer contacts(RS-AR2) Off-delay with auxiliary voltage with seperate start contact 1 changer contact (RS-AZ1) 2 changer contacts (RS-AZ2) Off-delay with auxiliary voltage with seperate start contact 1 changer contact (RS-LA1) 2 changer contacts (RS-LA2) Off-delay with auxiliary voltage with seperate start contact 1 changer contact Voltage on supply off tv Output closed relay open Voltage supply on off Control contact closed open Voltage supply on off Control contact closed open tv tv Time-delay closed open contact Time-delay closed open contact Specials and extras for you All devices up to category 1 according to EN 13849-1 Voltage supply on off Control Contact closed open tv Time-delay closed open contact Wiring diagram B1 15 A1 15 A1 15 A1 A2 16 18 A2 A2 18 16 A1 18 16 RS-AR1 LED 26 25 15 B2 25 1618 2628 28 A2 RS-AR2 1 LED B1 15 B2 A1 B1 A1 15 A1 B1 A2 B2 A1 B1 16 18 18 16 15 B1 A2 B2 26 16 A2 RS-AZ1 28 18 B1 B2 25 B2 15 25 16 18 2628 A2 RS-AZ2 2 LEDs B1 B2 15 B2 A1 B1 A1 B1 15 A2 B2 1618 18 16 A1 A1 B1 A2 B2 26 16 A2 RS-LA1 15 B1 28 18 B1 B2 25 B2 15 25 15 A1 B1 1618 2628 A2 B2 18 16 A2 RS-LA2 2 LEDs B2 15 B2 A1 B1 Our devices accord to VDE 0116 (regulation for combustion plants)! 16 18 A2 RS-AZS No Timing ranges 0.05 1s 0.15 3s 0.5 10 s 1.5 30 s 3 60 s 5 - 100 s 15 - 300 s 30 - 600 s (not possible with 24 V AC/DC) 0.05 0.15 0.5 1.5 3 5 15 30 - 24 V AC/DC 42- 48 V AC 110-127 V AC 230 V AC 12 24 42-48 110-127 230 1s 3s 10 s 30 s 60 s 100 s 300 s 600 s 1.5 3 0.15 0.5 - 30 min 60 min 3h 10 h 12 24 42-48 110-127 230 V AC/DC V AC/DC V AC V AC V AC Fixed times: 1 s, 3 s, 10 s, 30 s, 60 s, 100 s, 300 s, 600 s Are you missing a time range or do you need a fixed time? There are special customizing solutions riese-electronic is able to offer. For more information and questions you will find our contact address on the back of this leaflet. 12 24 42-48 110-127 230 Time-relays of riese- electronic also operate with 12 V. Exciting voltage Tolerances Attributes Description of function Column 4% V AC/DC V AC/DC V AC V AC V AC 4% 4% V AC/DC V AC/DC V AC V AC V AC 4% Voltage tolerance up to +/-30% CMOS technology Analog time setting Absolute scale CMOS technology Analog time setting Absolute scale CMOS technology Analog time setting Absolute scale CMOS technology Fixed times These devices are off-delay time lag relays without auxiliary voltage. The output relay attracts instantaneounsly upon applying the exciting voltage to terminals A1 and A2. The output relay remains closed upon interruption for the exciting voltage and the time begins. The output relay returns to it's normal position upon expiry of the set time These devices are release delaying time relays under auxiliary current. They are controlled by a separate start contact free of potential. Exciting voltage needs to be available at terminals A1 and A2 during operation of the device. After closing the potential free start contact B1-B2, the output relay will close promptly. After opening the start contact, the output relay remains closed and the timing will start. After course of the chosen time, the outlet relay goes back into basic position.Voltage at terminals B1 and B2 is 24 V DC. In closed position of the start contact current of approx. 10 mA will be measured. Min. operation time of the start contact is 5 ms. Note: There is no galvanic cut between connectors B1 or B2 and exciting voltage A1 and A2. see col. 9 see col. 9 8 9 10 Are you interested in "brandlabel" relays? Your and our free range for future ideas and developments. You would like to have your corporate symbol on safety-, time-delay-, or measuring- relays you are purchasing? Do you have certain housing forms you want to apply? We are able to provide you with many years of experience due to our customizing division. We are capable to meet your needs flexibly at any time. Let us know about your requirements. Whether there shall be only your logo on the relay, or also a certain colour or housing is demanded, we will create a complete brandlabel- project to develop, produce and test your specific relay, quick and with competence. 11 23 Timerelay Flashing Type Function/ Contact RS-BR1, RS-BR2 RS-BRS1, RS-BRS2 Flashing 1 changer contact (RS-BR1) 2 changer contacts(RS-BR2) Flashing 1 changer contact(RS-BRS1) 2 changer contact(RS-BRS2) Voltage on supply off Voltage on supply off Pulse schedule/ Function diagram All devices up to category 1 according to EN 13849-1 tv Output relay Specials and extras for you tv Output relay closed open closed open Wiring diagram A1 15 A1 15 A2 16 18 18 16 A1 A2 18 16 A2 RS-BR1 LED A1 15 26 25 15 15 A1 25 1618 2628 28 A2 RS-BR2 2 LEDs A1 15 A2 16 18 18 16 A1 15 A1 A2 18 16 A2 RS-BRS1 Our devices accord to VDE 0116 (regulation for combustion plants)! 26 25 15 25 16 18 26 28 28 A2 RS-BRS2 2 LEDs Timing ranges Fixed clock - pulse times: 0.25 0.25 s 0.5 0.5 s 0.75 0.75 s 1 1 s 1.5 1.5 s Variable clock - pulse times: 0.15 - 3 s Are you missing a time range or do you need a fixed time? There are special customizing solutions riese-electronic is able to offer. For more information and questions you will find our contact address on the back of this leaflet. Exciting voltage 12 24 42-48 110 230 Tolerances Attributes Description of function Column V AC/DC V AC/DC V AC V AC V AC 10% 12 24 42-48 110 230 V AC/DC V AC/DC V AC V AC V AC 10% Voltage tolerance up to +/-30% CMOS technology Fixed times CMOS technology Analog time setting Absolute scale These devices are flashing relays with fixed interval/pulse ratios and fixed clockpulse time (RS-BR). The time lag of the interval begins upon applying the exciting voltage to terminals A1 and A2. The output relay remains in its normal position. After the interval has expired, the output relay attracts and remains in this switched position until the pulse time has expired. This procedure repeats in a cycle until the exciting voltage is interrupted. These devices are flashing relays with fixed interval/pulse ratios and variable clock-pulse time. The time lag of the interval begins upon applying the exciting voltage to terminal A1 and A2. The output relay remains in its normal position. After the interval has expired, the output relay attracts and remains in this switched position until the pulse time has expired. This procedure repeats in a cycle until the exciting voltage is interrupted. 12 Time-relays of riese- electronic also operate with 12 V. 13 Are you interested in "brandlabel" relays? Your and our free range for future ideas and developments. You would like to have your corporate symbol on safety-, time-delay-, or measuring- relays you are purchasing? Do you have certain housing forms you want to apply? We are able to provide you with many years of experience due to our customizing division. We are capable to meet your needs flexibly at any time. Let us know about your requirements. Whether there shall be only your logo on the relay, or also a certain colour or housing is demanded, we will create a complete brandlabel- project to develop, produce and test your specific relay, quick and with competence. 23 Timerelay Clock-pulsed Type Function/ Contact Pulse schedule/ Function diagram RS-TG1, RS-TG2 RS-TGI1, RS-TGI2 Clock-pulsed starting with pause 1 changer contact (RS-TG1) 2 changer contacts (RS-TG2) Clock-pulsed starting with pulse 1 changer contact (RS-TGI1) 2 changer contact(RS-TGI2) Voltage on supply off Voltage on supply off t1 t2 t1 Output closed relay open interval pulse Specials and extras for you All devices up to category 1 according to EN 13849-1 Output closed relay open t1 t2 pulse interval t1 interval pulse Wiring diagram 15 A1 A1 A2 15 A1 16 18 18 16 RS-TG1 LED A1 15 A2 18 16 A2 26 25 15 15 A1 25 1618 26 28 28 A2 RS-TG2 1LED A1 15 A2 1618 18 16 RS-TGI1 A1 15 A1 A2 18 16 A2 Our devices accord to VDE 0116 (regulation for combustion plants)! 26 25 15 25 16 18 2628 28 A2 RS-TGI2 1LED Timing ranges Pulse and interval times from any combination of the following: 0.05 1s 0.15 3s 0.5 10 s 1.5 30 s 3 60 s 5 - 100 s 15 - 300 s 30 - 600 s Pulse and interval times from any combination of the following: 0.05 1s 0.15 3s 0.5 10 s 1.5 30 s 3 60 s 5 - 100 s 15 - 300 s 30 - 600 s Are you missing a time range or do you need a fixed time? There are special customizing solutions riese-electronic is able to offer. For more information and questions you will find our contact address on the back of this leaflet. 24 42-48 110-127 230 24 42-48 110-127 230 Time-relays of riese- electronic also operate with 12 V. Exciting voltage Tolerances Attributes Description of function Column V AC/DC V AC V AC V AC 4% V AC/DC V AC V AC V AC 4% Voltage tolerance up to +/-30% CMOS technology Analog time setting Relative scale CMOS technology Analog time setting Relative scale These devices are repeat cycle timers with individually adjustable pulse and interval times.The time lag of the interval begins upon applying the exciting voltage to terminals A1 and A2. The output relay remains in its normal position. After the interval has expired, the output relay attracts and remains in this switched position until the pulse time has expired. This procedure repeats in a cycle until the exciting voltage is interrupted. These devices are repeat cycle timers with individually adjustable pulse and interval times. The time lag of the pulse time begins upon applying the exciting voltage to terminals A1 and A2. The output relay attracts instantaneously and remains in this switched position for the puls time. After the pulse time has expired, the output relay returns to its normal position and the interval begins.This procedure repeats in a cycle until the exciting voltage is interrupted. Your and our free range for future ideas and developments. You would like to have your corporate symbol on safety-, time-delay-, or measuring- relays you are purchasing? Do you have certain housing forms you want to apply? We are able to provide you with many years of experience due to our customizing division. We are capable to meet your needs flexibly at any time. Let us know about your requirements. Whether there shall be only your logo on the relay, or also a certain colour or housing is demanded, we will create a complete brandlabel- project to develop, produce and test your specific relay, quick and with competence. 14 15 23 Are you interested in "brandlabel" relays? Multifunction relay Type Function/ Contact Pulse schedule/ Function diagram RS-MF Multifunction relay 2 changer contacts Specials and extras for you Pulse schedule depends on function: EV see col. 1 AV see col. 9 EW see col. 17 TP see col. 12 TI see technical specifications EWI see technical specifications All devices up to category 1 according to EN 13849-1 Wiring diagram B1 A1 A3 15 B1 A1 A2 26 16 25 B2 15 potential-free contact B1 - B2 Our devices accord to VDE 0116 (regulation for combustion plants)! 25 16 18 26 28 28 18 A2 RS-MF LED 2 LEDs Timing ranges 0.15 0.6 5 40 or: 0.15 0.6 5 40 3s - 12 s - 100 s - 800 s 3 min - 12 min - 100 min - 800 min Are you missing a time range or do you need a fixed time? There are special customizing solutions riese-electronic is able to offer. For more information and questions you will find our contact address on the back of this leaflet. Exciting voltage Exciting voltage 1 (A1-A2) 90-250 V AC and exciting voltage 2 (A1-A3) 24 V AC/DC (only one voltage may be applied to the relay at the same time) Tolerances Attributes Description of function Column 4% Time-relays of riese- electronic also operate with 12 V. Voltage tolerance up to +/-30% CMOS technology Analog time setting Relative scale Are you interested in "brandlabel" relays? The functions: EV = on-delay AV = off-delay with auxiliary voltage EW = making-pulse contact/ pulse clipping TP = clock-pulsed, starting with pulse TI = clock-pulsed, starting with interval EWI = making-pulse contact/ pulse forming can be set by means of DIP switches on the front. Your and our free range for future ideas and developments. You would like to have your corporate symbol on safety-, time-delay-, or measuring- relays you are purchasing? Do you have certain housing forms you want to apply? We are able to provide you with many years of experience due to our customizing division. We are capable to meet your needs flexibly at any time. Let us know about your requirements. Whether there shall be only your logo on the relay, or also a certain colour or housing is demanded, we will create a complete brandlabel- project to develop, produce and test your specific relay, quick and with competence. 16 23 Interval time relay Type Function/ Contact Pulse schedule/ Function diagram RS-EI1, RS-EI2 RS-EIF RS-WAR Interval time relay 1 changer contact (RS-EI1) 2 changer contacts (RS-EI2) Interval time relay 1 changer contact and remote connection Interval time relay multifunction 1 changer contact Voltage on supply off Voltage on supply off tv tv Output closed relay open tv tv Output closed relay open Specials and extras for you All devices up to category 1 according to EN 13849-1 Voltage on supply off tv tv Output closed relay open Wiring diagram 15 A1 A1 15 A2 1618 18 16 A1 A2 18 16 A2 RS-EI1 LED A1 15 26 25 15 25 A1 Z1 15 1618 2628 A2 Z2 16 18 18 16 28 A2 15 X2 X3 X1X2 X3 15 A1 Our devices accord to VDE 0116 (regulation for combustion plants)! A2 16 18 16 A2 18 A2 RS-WAR RS-EIF RS-EI2 2 LEDs A1 X1 15 Z2 A1 Z1 2 LEDs No Timing ranges 0.05 0.15 0.5 1.5 3 5 15 30 - 1s 3s 10 s 30 s 60 s 100 s 300 s 600 s 0.05 0.15 0.5 1.5 3 5 15 30 - 1s 3s 10 s 30 s 60 s 100 s 300 s 600 s Fixed time: 0.5 s Are you missing a time range or do you need a fixed time? There are special customizing solutions riese-electronic is able to offer. For more information and questions you will find our contact address on the back of this leaflet. V AC/DC V AC V AC V AC 24 V AC/DC 110-127 V AC 230 V AC Time-relays of riese- electronic also operate with 12 V. CMOS technology Analog time setting Absolute scale CMOS technology Analog time setting Absolute scale Analog time setting Fixed time These devices are electronic pulse-clipping relays. After applying the exciting voltage to terminal A1 and A2, the output relay attracts instantaneously and remains in this switched position for the set time. Then it returns to its normal position. Resistance value for all time ranges is 10 kΩ. The factory fitted jumper is to be removed upon connecting an externel potentiometer for setting the time. The remote potentiometer is to be connected to terminal Z1 and Z2. The internal potentiometer is to be set to the shortest time. The lines to the external potentiometer may be up to 100 m long. Note: there is no electrical isolation between terminal Z1 and Z2 and the exciting voltage A1 and A2. These devices are electronic pulse-clipping relays The functions: EW = making-pulse contact AW = breaking-pulse contact and Exciting voltage 24 42-48 110-127 230 Tolerances Attributes Description of function V AC/DC V AC V AC V AC 10% 24 42-48 110-127 230 10% 20% Voltage tolerance up to +/-30% EW/AW = making- and breaking-pulse contact can be set via jumpers at terminals X1, X2 and X3. X1-X2 = EW X2-X3 = AW no jumper = EW/AW Column 17 18 19 Are you interested in "brandlabel" relays? Your and our free range for future ideas and developments. You would like to have your corporate symbol on safety-, time-delay-, or measuring- relays you are purchasing? Do you have certain housing forms you want to apply? We are able to provide you with many years of experience due to our customizing division. We are capable to meet your needs flexibly at any time. Let us know about your requirements. Whether there shall be only your logo on the relay, or also a certain colour or housing is demanded, we will create a complete brandlabel- project to develop, produce and test your specific relay, quick and with competence. 23 Star-delta-relay Type Function/ Contact Pulse schedule/ Function diagram RS-SD RS-SDS Star-delta relay 1 changer contact with change-over time Star-delta relay 2 normally open contacts with change-over time All devices up to category 1 according to EN 13849-1 Voltage on supply off Voltage on supply off Specials and extras for you closed NO (17/18) open closed NC (15/16) open tv 1 tv1 tv 2 tv2 closed NO (27/28) open closed NO (15/18) open Wiring diagram 15 A1 A1 A1 17 15 27 A1 17 A2 18 Our devices accord to VDE 0116 (regulation for combustion plants)! 27 100 ms A2 1618 18 16 A2 RS-SD LED 28 28 A2 18 RS-SDS 2 LEDs 2 LEDs 1.5 - 30 s 3 - 60 s 5 - 100 s 1.5 - 30 s 3 - 60 s 5 - 100 s Change-over times: 30, 50, 100 ms Change-over times: 30, 50, 100 ms 24 42-48 110-127 230 24 42-48 110-127 230 Timing ranges Are you missing a time range or do you need a fixed time? There are special customizing solutions riese-electronic is able to offer. For more information and questions you will find our contact address on the back of this leaflet. Exciting voltage Tolerances Attributes Description of function Column V AC/DC V AC V AC V AC 4% V AC/DC V AC V AC V AC 4% Time-relays of riese- electronic also operate with 12 V. Voltage tolerance up to +/-30% CMOS technology Analog time setting Absolute scale CMOS technology Analog time setting Absolute scale Are you interested in "brandlabel" relays? This is an on-delay time-lag relay with change-over time.The time lag begins after applying the exciting voltage to terminals A1 and A2. The output relay remains in its normal position. After expiry of time, the output relay attracts with a changeover time and remains in this switched position until the exciting voltage is interrupted. Upon interruption of the exciting voltage, the output relay returns to it's normal position The RS-SDS is a time delayed relay for star-delta change-over. After connecting the voltage supply to terminal A1 and A2, the NO-contact 1 (17-18) will close immediately and stay in this position with the duration of the adjusted time tv1. At the end of the time tv1 and end of the change-over time (selectable time of 30, 50 and 100 ms) the NO-contact 1 (1718) opens and NO-contact 2 (27-28) close. NO-contact 2 keeps close till disconnecting the voltage supply. After disconnecting the voltage supply the RS-SDS falls back in its basic position (NOcontact 1 and 2 are open). Your and our free range for future ideas and developments. You would like to have your corporate symbol on safety-, time-delay-, or measuring- relays you are purchasing? Do you have certain housing forms you want to apply? We are able to provide you with many years of experience due to our customizing division. We are capable to meet your needs flexibly at any time. Let us know about your requirements. Whether there shall be only your logo on the relay, or also a certain colour or housing is demanded, we will create a complete brandlabel- project to develop, produce and test your specific relay, quick and with competence. 20 21 23 Headquarter Subsidiary East riese electronic gmbh Industrievertretung für Automation und Sicherheit Dr.-Riese-Str. 1 07937 Langenwolschendorf Telefon +49 (0) 3 66 28 7 25 0 Telefax +49 (0) 3 66 28 7 25 17 info-lawo@automation-sicherheit.de www.automation-safety.com Junghansstr. 16 72160 Horb am Neckar Telefon +49 (0) 74 51 55 01 0 Telefax +49 (0) 74 51 55 01 70 info@riese-electronic.de www.automation-safety.com EUROPE Austria Distributor Reliste Steuerungstechnik GesmbH Vertriebsleitung Enzersdorfer Str. 8-10 A-2345 Brunn am Gebirge Phone +43 22 36 31 52 50 Fax +43 22 36 31 52 56 0 office@reliste.at www.reliste.at Belgium Belgium Representative Koning & Hartmann B.V. Div. Multitechnic Woluwelaan 31 B-1800 Vilvoorde Phone +32 22 57 02 40 Mobil +0478 93 90 26 Fax +32 22 57 02 49 michael.wauters@KoningenHartmann.be www.multitechnic.be Distributor Rotero Belgium BVBA Wayenborgstraat 10 B-2800 Mechelen Phone +32 15 45 18 40 Fax +32 15 45 18 41 info@rotero.be www.rotero.be Belgium Finland Great Britain Distributor Laumans Techniek B.V.: Weertersteenweg 138/2 B-3680 Kinrooi Phone +32 89 70 20 96 Fax +32 89 70 20 97 sales@laumans.com www.laumans.com Representative UTU Powel Oy, Components P.O.Box 33, Palopellonkatu 7 FIN-04251 Kerava Phone +35 89 27 46 41 1 Fax +35 89 27 46 41 41 powel@utu.eu www.utupowel.fi Representative Euchner /U.K. Ltd. Sheffield S4 7PZ Phone +44 11 42 56 01 23 Fax +44 11 42 42 53 33 euchneruk@email.msn.com www.euchner.com Greece Hungary Italy Distributor L. J. Skourgialos Industrial Automation Systems 241 El. Venizelou Ave 176 73 Lallithea Phone +30 21 09 51 02 60 Fax +30 21 09 51 10 48 ias@otenet.gr www.ias.gr Representative Merker 2007 Zrt. Kistályai út 14. H-3300 Eger Phone +36 36 52 42 00 Fax +36 36 31 15 10 ferenczm@tervker.hu www.tervker.hu Representative Tecnel System SpA Via Brunico 15 I-20126 Milano Phone +39 02 25 78 80 3 Fax +39 02 27 00 10 38 tecnel@tecnelsystem.it www.tecnelsystem.it Netherlands Netherlands Netherlands Distributor Laumans Techniek B.V.: NL-6003 DC Weert Phone +31 49 55 21 06 7 Fax +31 49 55 42 45 7 sales@laumans.com www.laumans.com Distributor Rotero B.V. Postbus 126 NL-3440 AC Woerden Phone +31 34 84 95 15 0 Fax +31 34 84 95 17 1 info@rotero.com www.rotero.com Distributor Isotron Systems B.V. De Merrheuvel 6A NL-5202 CE Hertgenbosch Phone +31 73 63 91 63 9 Fax +31 73 63 91 69 9 info@isotron.nl www.isotron.nl Spain Switzerland Switzerland Representative Soltekin S.L. Apdo. Correos No 62 C/EI Fou No 84 E-08440 Cardedeu Phone +34 (9) 38 71 19 45 Fax +34 (9) 38 46 23 32 central@soltekin.com www.soltekin.com Representative Bachofen AG Industrielle Automation Abteilung Schalttechnik Ackerstrassen 42 CH-8610 Uster Phone +41 (0) 44 944 11 11 Fax +41 (0) 44 944 10 04 sg@bachofen.ch www.bachofen.ch Distributor Surber AG Industriestr. 7 CH-4653 Obergösgen Phone +41 62 29 50 33 3 Fax +41 62 29 50 30 2 info@surberag.ch www.surberag.ch WORLDWIDE Brazil China South Africa Representative Westcon Industrial Ltd. Rua Alvaro Rodrigues, 257 04582-000 Sao Paulo-SP Brazil Telefon +55 11 55 61 74 88 Telefax +55 11 50 93 25 92 paolo@wii.com.br www.wii.com.br Distributor Beijing Controlway Tech & Trade Ltd. 100089 Beijing, P.R.C China Telefon +86 10 88 47 09 73 Telefax +86 10 88 44 71 90 georgejwu@controlway.cn www.controlway.com Representative Curmec CC P.O.Box 1818 Bedfordview 2008/Gauteng ZA-Germiston 1401 Phone +27 11 87 30 53 6 Fax +27 11 87 39 74 3 info@curmec.co.za www.curmec.co.za South Korea Taiwan USA/Canada/Mexico Representative TELKO Korea Co. Ltd. Seoul, Korea Phone +82 23 27 37 80 0 Fax +82 23 27 37 80 2 telko@unitel.co.kr www.telko.co.kr Representative Daybreak International (Taiwan) Corporation TAIPEI, ROC TAIWAN Phone +88 62 88 66 12 31 Fax +88 62 88 66 12 39 day111@ms23.hinet.net www.daybreak.com.tw Representative Norstat Inc. ROCKAWAY, NJ 07866, USA Phone +1 (973) 586 25 00 Fax +1 (973) 586 15 90 info@norstat.com www.norstat.com Handed over by: