HP1050 - McDonald Lab
Transcription
HP1050 - McDonald Lab
1050 Series of HPLC Modules Service Handbook Copyright Agilent Technologies 2001 All rights reserved. Reproduction, adaption, or translation without prior written permission is prohibited, except as allowed under the copyright laws. Part No. NONE 09/2001 Printed in Germany Warranty IMPORTANT NOTE The information contained in this document is subject to change without notice. This version of the 1050 service manual includes all sections from the 01050-90102 edition 4 (1995). Agilent Technologies makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties or merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Agilent Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn Germany The series I opticals information (79854A MWD and G1306A DAD) and the 79853A VWD information has been removed (products went out of support during 2000). Part numbers have been updated as of 09/2001. Contact your local Agilent support office in case of part number issues or upgrades. The latest version of this manual is available as Adobe Acrobat Reader (PDF) version only and can be downloaded from the Agilent Technolgies web page www.agilent.com. Contents 1 Common: General Information This chapter provides general information about the 1050 Series of HPLC Modules 29 Safety Information 30 General 30 Operation 30 Safety Symbols 32 Radio Interference 33 Manufacturer’s Declaration Sound Emission 33 33 Manufacturer’s Declaration UV-Radiation 34 Solvent Information 33 35 Flow Cell 35 Solvents 35 1050 Introduction 36 The Modules Overview 36 1050 Identification 38 Repair Policy 38 2 Common: Electronic Information This chapter provides common electronic information about the 1050 Series of HPLC Modules 39 Overview 41 Common Main Processor Board (CMP) 42 Common 1050 Functions CMP Details 44 Remote Control 47 42 Service Handbook for 1050 Series of HPLC Modules - 09/2001 3 Contents Firmware Board (FIM) Firmware Description 53 53 Fluorescent Indicator Module (FIP) External Contacts 56 Power Supply (DPS-B / DPS-A) 57 55 General Description 57 Base Supply (DPS-B) 58 Lamp Supply (DPS-A) 60 Communication Interface (CIB / CRB) 64 3 Common: Cable Information This chapter provides information on cables for the 1050 Modules 67 Overview 68 Analog Cables 70 Remote Cables 72 BCD Cables 77 4 Pumps: General Information This chapter provides general information about the 1050 Pumps 83 Introduction 84 About this Manual 84 About the Pumps 85 Repair Policy 85 Product Structure 86 4 Service Handbook for 1050 Series of HPLC Modules - 09/2001 Contents Capillaries 87 Specifications 88 5 Pumps: Hardware Information This chapter provides hardware information about the 1050 Pumps 91 Overview 93 How does the Pump Work? 95 Isocratic Operation Gradient Operation 95 96 Overview of the Electronics 96 Overview of the Flow Path 98 Solvent Cabinet 99 Helium Degassing 99 Manual Injection Valve Column Heater 100 100 Multi Channel Gradient Valve (MCGV) Metering Drive Assembly 103 Pump Head Assembly 104 Continuous Seal Wash 105 Active Inlet Valve 107 Outlet Ball Valve 108 Frit Adapter Assembly 109 Purge Valve 110 High Pressure Damper 111 Column Holder 112 102 Service Handbook for 1050 Series of HPLC Modules - 09/2001 5 Contents 6 Pumps: Electronic Information This chapter provides electronic information about the 1050 Pumps 113 Overview 115 Pump Drive Control Board (PDC2) 118 Relative A/D Converter Board (RAD) 123 Firmware Board (SFW) 127 HRI Board - Heater Isocratic Board 128 Heater Quaternary Board (HRQ) 131 High Pressure Transducer Board (HPT) 134 Connector Board (CON) 136 Pump Motherboard (HPS) 138 7 Pumps: Diagnostic Information This chapter provides information on error messages and diagnostic features of the 1050 Pumps 143 How to use the Diagnostic Test Functions Pump Pressure Ripple 146 Flow (Pressure) Tests 147 Prerequisites for the Pressure Tests 148 Normal Pressure Test 149 The Modified Pressure Test 150 Flow Test Method 151 Flow Test Method - Firmware Rev. 1.0 152 Flow Test Method - Firmware Rev. 3.0 and above Gradient Test Method 157 159 Prerequisites for the Gradient Test Method Running the Gradient Test Method 159 6 145 159 Service Handbook for 1050 Series of HPLC Modules - 09/2001 Contents Error Messages Selftest 163 ROM/RAM Test 162 163 Panic Error / Bus Error Address Error 164 Common 1050 Error Messages 165 Pump Initialization Error Messages 167 Normal Operation Error Messages 171 Column Heater Error Messages 175 Online Monitor Messages 177 Troubleshooting Hints 180 Standard Pressure Tests with different Solvents 181 Modified Pressure Tests 181 Pressure Tests - Firmware Revision 1.0 182 Pressure Tests - Firmware Revision 3.0 and above 184 Pressure Tests when the Pump is broken 185 Pressure Tests - Leak at Piston Seal 1 186 Pressure Tests - Leak at Piston Seal 2 189 Pressure Tests - Defective Piston 1 192 Pressure Tests - Defective Piston 2 196 Pressure Tests - Defective Active Inlet Valve 200 8 Pumps: Maintenance Information This chapter provides provide procedures for service and maintenance of the 1050 Pumps 203 Solvent Cabinet and Column Heater 205 Replacing the Heat Exchanger 205 Replacing the Cable Assembly 206 Replacing the Active Inlet Valve 207 Service Handbook for 1050 Series of HPLC Modules - 09/2001 7 Contents Replacing the Outlet Ball Valve 209 Maintaining the Frit Adapter Assembly Maintaining the Purge Valve 211 210 Maintaining the Pump Head Assembly 212 Procedure 1: Pump Head with old Plunger Housing 213 Stage 1: Removing the Pump Head Assembly 213 Stage 2: Disassembling the Pump Head assembly 213 Stage 3: Replacing the Seals 214 Stage 4: Disassembling the Plunger Housing 215 Stage 5: Reassembling the Plunger Housing 216 Stage 6: Reassembling the Pump Head Assembly 217 Stage 7: Mounting the Pump Head Assembly 217 Procedure 2: Pump Head with new Plunger Housing 218 Stage 1: Removing the Pump Head Assembly 218 Stage 2: Disassembling the Pump Head Assembly 218 Stage 3: Replacing the Seals 219 Stage 4: Reassembling the Pump Head Assembly 220 Stage 5: Mounting the Pump Head Assembly 220 Continuous Seal Wash Option 221 Replacing the Fan 222 Removing the Metering Drive Assembly 223 9 Pumps: Parts Information This chapter provides information on parts of the 1050 Pumps 225 Electronic Boards 227 Complete List of Ti-Parts 229 Solvent Cabinet 230 8 Service Handbook for 1050 Series of HPLC Modules - 09/2001 Contents Solvent Cabinet with Helium Degassing 232 Solvent Cabinet with Column Heater and Manual Injection Valve 234 Overall Diagram 236 Hydraulic Flow Path 240 Metering Drive Assembly 243 Pump Head Assembly (old version) 244 Pump Head Assembly (new version) 245 Pump Head Assembly with Seal Wash 246 Active Inlet Valve 248 Outlet Ball Valve 249 Frit Adapter Assembly 250 Purge Valve Assembly 251 Column Holder Assembly 252 Special Tools 253 10Pumps: Additional Information This chapter provides additional information about the 1050 Pumps 255 Product History 257 Firmware History 259 Revision 1.0 Revision 3.0 Revision 3.1 Revision 3.2 259 259 260 260 How does the On-line Monitor work 261 Normal Operation 262 M2 Gas Bubble 263 M4 Leak at first Piston 265 Service Handbook for 1050 Series of HPLC Modules - 09/2001 9 Contents M6 Valve Backflow 266 M8 Outlet Valve Problem 267 If You Need Operational Hints 268 Helium Degassing Principle 269 Helium Regulators 269 Bottle Head Assembly 270 Isocratic Pumps 270 Pump Head Assembly 271 PDC Board 271 PDC2 Board 271 HRQ Board 272 GVD Board 272 Wear Retainer 272 Outlet Ball Valve 273 Flow Test Method 273 Method loading 273 Flow Gradients 273 Manual Injection Valve 273 Metering Drive Repairs 274 Troubleshooting E27 Errors (Max Motor Drive Power Exceeded) Piston with Conical Holder 276 Ghost Leak messages 276 PANIC Errors 276 275 11Sampler: General Information This chapter provides general information about the 1050 Autosampler 281 About this Manual 282 About the Autosampler 282 Repair Policy 283 10 Service Handbook for 1050 Series of HPLC Modules - 09/2001 Contents Product Structure 283 Capillaries 284 Specifications 285 12Sampler: Hardware Information This chapter provides hardware information about the 1050 Autosampler 287 Overview 289 Solvent Flow Path 290 How Does The Autosampler Work? 291 The Injection Sequence 293 What happens when the 18596L/M Sample Tray is connected? 294 Overview of the Electronics 295 Sampling Unit 297 Metering Drive 299 Analytical Head Assembly 300 High Pressure Switching Valve 301 Pneumatic Assembly 302 Actuator Air Solenoids 303 Additional 100 Sample Capacity 304 13Sampler: Electronic Information This chapter provides electronic information about the 1050 Autosampler 307 Overview 309 Service Handbook for 1050 Series of HPLC Modules - 09/2001 11 Contents Max Tray Drive Board (MTD) 312 Needle Mini Tray Drive Board (NMD) 316 Valve Metering Drive Board (VMD) 320 Firmware Board (FIM) 324 Autosampler Motherboard (ALM) 325 Extender Test Board (ET) 330 14Sampler: Diagnostic Information This chapter provides information on error messages and diagnostic features of the 1050 Autosampler 333 Single Steps 335 Entering the Test Functions 335 Single Steps For The 21 Sample Tray 336 Single Steps for the 100 Sample Tray 338 Entering the Additional Single Steps 338 18596L/M Sample Tray Diagnostic Mode 340 Entering Diagnostic Mode 340 Z Test (Gripper Assembly) 340 R Test (radial arm movement) 341 Theta Test (angular movement) 341 Error Messages 342 Selftest 343 Panic Error 343 Common 1050 Error Messages 344 Error Messages for Firmware Revision 4.0 and greater 346 Injector Program Error Messages 350 Normal Operation Messages for Firmware Revision 3.1 and below 351 Events Messages 354 12 Service Handbook for 1050 Series of HPLC Modules - 09/2001 Contents 18596L/M Vial Tray 355 15Sampler: Maintenance Information This chapter provides provide procedures for service and maintenance of the 1050 Autosampler 357 Sampling Unit 359 Stage 1: Removing the Sampling Unit 359 Stage 2: Removing the Needle 360 Stage 3: Installation of the Needle 361 Stage 4: Removing the Seat Capillary 361 Stage 5: Disassembling the Needle Arm 362 Stage 6: Reassembling the Needle Arm 362 Stage 7: Disassembling the Tray Mechanic 363 Metering Device 365 Removing the Metering Device 365 Removing the Gear Belt 365 Analytical Head Assembly 366 Procedure 1: Analytical Head Assembly with old Adapter Housing Procedure 2: Analytical Head with new Adapter Housing 369 Reassembling the Metering Device 371 High Pressure Switching Valve 366 372 Stage 1: Removing 372 Stage 2: Disassembling 372 Adjust the Sensors 374 Service Only Level 374 Sensors of the Sampling Unit 376 Sensor of the High Pressure Switching Valve Metering Device Home Sensor 380 379 Service Handbook for 1050 Series of HPLC Modules - 09/2001 13 Contents 16Sampler: Parts Information This chapter provides information on parts of the 1050 Autosampler 381 Electronic Boards and Fuses 383 Electronic Boards Fuses 383 383 Complete List of Ti-Parts 384 Overall Diagram 79855A/B 385 Hydraulic Flow Path 389 Sampling Unit 391 Arm Assembly Spare Parts 395 Metering Drive and Analytical Head Metering Drive 396 Analytical Head (Old Version) 396 396 High Pressure Switching Valve 399 Pneumatic Valve Assembly 401 17Sampler: Additional Information This chapter provides additional information about the 1050 Autosampler 403 Product History 405 Firmware Revisions 406 Firmware Revision 1.0 Firmware Revision 2.0 Firmware Revision 2.1 Firmware Revision 3.0 Firmware Revision 3.1 Firmware Revision 4.0 14 406 406 407 408 409 410 Service Handbook for 1050 Series of HPLC Modules - 09/2001 Contents Firmware Revision 4.1 411 Firmware Revision 4.2 411 If you update the firmware to revision 4.0 and greater 412 If you add a 100 vial tray to the autosampler 412 If you have Intermittant E17: Needle cannot move out of vial If you have to update the autosampler with a fan 413 If the fan in the autosampler does not work properly 413 If the needle lifts the vial out of the tray 414 If the injections are not reproducible (grooved needle) 414 413 18DAD/MWD: General Information This chapter provides general information about the 1050 Diode Array and Multiple Wavelength Detectors 419 About the Detector 420 General 420 Repair Policy 420 Identification 421 Compatibility 421 DAD Differences 422 Added features 422 Removed features from local keyboard Restrictions of user interface 423 Compatibility 423 Local User Interface 424 Workstation Interface 426 Test Functions 428 Options 428 422 Specifications DAD/MWD 429 Service Handbook for 1050 Series of HPLC Modules - 09/2001 15 Contents 19DAD/MWD: Hardware Information This chapter provides hardware information about the 050 Diode Array and Multiple Wavelength Detectors 433 Overview: Optical System 435 Overview: Electronics 436 Optical Unit 438 Flow Cell Assemblies 439 Slit Assembly 441 Deuterium Lamp Assembly 442 Heat Exchanger Assembly 444 Shutter Assembly 445 Leak Sensor Assembly 446 Fans 447 20DAD/MWD: Electronic Information This chapter provides electronic information about the 1050 Diode Array and Multiple Wavelength Detectors 449 Overview 451 Array Signal Conversion Board (ASC) 454 Data Acquisition Board (AQB) 459 Firmware Board (FIM) 463 Common Main Processor Board (CMP) 464 Remote Control 466 Communication Interface (CRB) 467 Digital to Analog Conversion Board (DAC) Fluorescent Indicator Module (FIP) 472 Motherboard (LUM) 473 LPC Board 477 16 468 Service Handbook for 1050 Series of HPLC Modules - 09/2001 Contents Power Supply (DPS-A) 478 21DAD/MWD: Diagnostic & Troubleshooting Information This chapter provides information on error messages and diagnostic features of the 1050 Diode Array and Multiple Wavelength Detectors 483 STATUS Information 485 Status Modes 485 Status LEDs 486 Warnings 486 Error Messages 487 Selftest 487 Common 1050 Error Messages 488 1050 DAD/WMD Error Messages 490 Diagnostic Features 493 Entering the Test Functions 493 Measure Intensity Profile 494 Lamp Intensity Test 496 Measure Holmium Spectrum 498 D/A Converter Test 500 Electronic Noise Test 502 Check of Wavelength Calibration 504 ASC Test 505 Shutter Position 506 ROM/RAM/DISPLAY Tests 507 Using the Built-in Test Chromatogram 508 How to print the DAD Profiles 510 Service Handbook for 1050 Series of HPLC Modules - 09/2001 17 Contents 22DAD/MWD: Maintenance Information This chapter provides provide procedures for service and maintenance of the 1050 Diode Array and Multiple Wavelength Detectors 513 Tools Needed 514 Warnings and Notes 515 Removing the Optical Unit 516 Flow Cell Maintenance 517 Flushing Procedure 517 Replacements on Standard Flow Cells 518 Replacements on High Pressure Flow Cells 520 Lamp House Window Maintenance Removing the Quartz Window 522 522 Replacing the Achromat 524 Replacing Fans 525 Replacement of Shutter or LPC Board 526 Replacement of Leak Sensor 527 Upgrade to from 79854A MWD to G1306A DAD 528 Upgrade MWD with Series II Optical 529 Verifying the Performance 530 Specifications 530 What You Need 530 Preparations 530 Scaling Factors 532 23DAD/MWD: Parts Information This chapter provides information on parts of the 1050 Diode Array and Multiple Wavelength Detectors 533 18 Service Handbook for 1050 Series of HPLC Modules - 09/2001 Contents Overall Diagram 535 Optical Unit 538 Heat Exchanger and Flow Cell 540 Flow Cell Parts (STD-SST) 541 High Pressure Flow Cell Parts (HP-STD-SST) 542 High Pressure Flow Cell Parts (HP-Micro-SST) 543 Cell Repair Kits 544 Lamp Housing 545 Upgrade Parts MWD to DAD 546 Upgrade Parts MWD to Series II Optical 547 List of Accessories 548 24DAD/MWD: Additional Information This chapter provides additional information about the 1050 Diode Array and Multiple Wavelength Detectors 549 Product History Hardware Changes 551 551 Firmware Changes 552 Known Problems 553 Panic Errors 553 25VWD: General Information This chapter provides general information about the 1050 Variable Wavelength Detectors 559 About the Detector 561 Versions vs. Support Periods (EOS) 561 Service Handbook for 1050 Series of HPLC Modules - 09/2001 19 Contents 79853A 79853C 561 561 Repair Policy 562 Specifications 563 26VWD: Hardware Information This chapter provides hardware information about the 1050 Variable Wavelength Detectors 565 Overview 566 Optical System Overview 568 Leak Interface Assembly 569 Leak Sensor Assembly 570 Fan Assemblies 571 Optical Unit 572 Flow Cells 573 Deuterium Lamp 576 Photodiodes Assemblies 579 Filter Assembly 580 Grating Assembly and Motor 581 Mirrors 582 Slit Assemblies 582 Beam Splitter 582 Enhanced Optical Unit (“D”) 583 27VWD: Electronic Information This chapter provides electronic information about the 1050 Variable Wavelength Detectors 585 20 Service Handbook for 1050 Series of HPLC Modules - 09/2001 Contents Location of Electronic Assemblies 587 Interconnection Diagram 589 Detector Controller Board (DCB) 590 Digital Section 592 Analog Sections 594 Power Supply (DPS-A) Keyboard 602 601 Keyboard Electronics (KDI / VFD) 603 Pre-Amplifier Boards 605 Power Supply Connection Board (PSC) 606 GPIB Communication Interface 607 GPIB Firmware Revisions 608 28VWD: Diagnostic & Troubleshooting Information This chapter provides information on error messages and diagnostic features of the 1050 Variable Wavelength Detectors 609 Self Diagnosis 611 During Power On 611 During Normal Operation 611 Error Messages Before Lamp Ignition At Power ON 612 612 Error Messages After Lamp Ignition 616 Error Messages During Normal Operation 617 Error Messages During Use of Control Functions 619 User Control Functions 620 Service Control Functions 622 Entering the Service Mode 622 Zero Order Calibration 624 Service Handbook for 1050 Series of HPLC Modules - 09/2001 21 Contents Wavelength Calibration 626 Wavelength Calibration Check 628 SET WL Parameter 629 Fix Signal 631 Leak Sensor Voltage 634 Voltage Test 635 ADC Noise 636 Grating Photo Sensor 637 Filter Photo Sensor 638 Remote Test 639 Filter Check 640 Zero Order Test 641 DAC Test 642 Pre-amplifier Gain 644 EEROM Test 645 DAC Calibration 646 Wavelength Compensation 647 29VWD: Maintenance Information This chapter provides provide procedures for service and maintenance of the 1050 Variable Wavelength Detectors 649 Warnings 650 Securing for Transport 651 Replacement of Deuterium Lamp 652 Step 1: Replacement 652 Step 2: 0th Order Calibration 653 Step 3: WL CALIBRATION 654 Flow Cell Maintenance Flow Cell Maintenance Kits Replacing Cell Parts 655 22 655 655 Service Handbook for 1050 Series of HPLC Modules - 09/2001 Contents Flushing Procedure Leak Test 657 656 Using the Cuvette Holder 658 Replacing DCB Board and Firmware 661 DCB Board 661 DCB Firmware 661 Replacing Display Boards 662 Replacing the Leak Interface 663 Leak Sensor Assembly Leak Interface 664 663 Replacements in the Optical Unit 665 Removing the Optical Unit 666 Replacing the PSC Board 667 Replacing Pre-amplifiers or Photodiodes 667 Replacing Grating Assembly Parts 668 Replacing Filter Assembly Parts 670 Replacing Mirrors, Beamsplitter and Slits 670 Optical Alignment Procedures 671 Procedure 1: Simple Alignment 671 Procedure 2: Sample Beam Alignment 672 Procedure 3: Reference Beam Alignment 674 Cleaning of Optical Unit Parts 675 Upgrade to GPIB 676 Performance Verification 677 What you need 677 Preparations 677 Starting a run 678 Scaling Factors 679 30VWD: Parts Information This chapter provides information on parts of the 1050 Vari- Service Handbook for 1050 Series of HPLC Modules - 09/2001 23 Contents able Wavelength Detectors 681 Overall Diagram 683 Front Panel Parts 686 Leak Interface 686 Font Panel 687 Optical Unit “C” 688 Optical Unit “C” Inner Parts Top 689 Optical Unit “C” Inner Parts Bottom 690 Grating Assembly 691 Filter Assembly 692 Standard Flow Cell “C” (SST/Ti) 693 Semi-Micro Flow Cell (SST) 695 High Pressure Flow Cell (SST) 696 Ultra High Pressure Flow Cell (SST) 697 Preparative Flow Cell (Ti) 698 Cuvette Holder 700 Accessories 701 Screws 702 31VWD: Enhanced Optical Unit Information This chapter provides information about the enhanced optical unit “D” 705 Compatibility 706 Support of Previous Optical Units Introduction 707 Support Considerations 708 706 Prefix Change 708 Identification 708 24 Service Handbook for 1050 Series of HPLC Modules - 09/2001 Contents Compatibility Matrix 708 Part Numbers for Enhanced “D” Optical Unit 709 Standard Flow Cell “D” Repair Parts 710 Repair and Mainenance 711 Tools required: 711 Pre-requisites: 711 Additional Information 712 Replacements and Calibrations 712 Installing the Test Slit 713 Replacing Mirror #1 Assembly 715 Replacing Mirror #3 or #4 Assembly 716 Replacing the Grating or Grating Motor 718 Replacing the Beam Splitter 720 Cleaning or Replacing the Lens 721 Unlocking the Reference Aperture 723 Optimizing the Reference Readings 725 Installing the Standard Slit 726 32VWD: Additional Information This chapter provides additional information about the 1050 Variable Wavelength Detectors 727 Product History Prefix Changes 729 729 DCB ROM Firmware Revisions 731 GPIB ROM Firmware Revisions 733 Hardware Changes and Service Notes 734 Modified Pre-Amplifier Gain 734 Important Service Note 734 Service Handbook for 1050 Series of HPLC Modules - 09/2001 25 Contents 26 Service Handbook for 1050 Series of HPLC Modules - 09/2001 1050 Series of HPLC Modules Service Handbook Common Information Copyright Agilent Technologies 2001 All rights reserved. Reproduction, adaption, or translation without prior written permission is prohibited, except as allowed under the copyright laws. Part No. NONE 11/2001 Printed in Germany Warranty IMPORTANT NOTE The information contained in this document is subject to change without notice. This version of the 1050 service manual includes all sections from the 01050-90102 edition 4 (1995) and G1306-90102 edition 2 (May 1994). It merges both sections, the MWD and the DAD. Agilent Technologies makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties or merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Agilent Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn Germany The series I opticals information (79854A MWD) information has been removed (product went out of support during 2000). Part numbers have been updated as of 11/2001. Contact your local Agilent support office in case of part number issues or upgrades. The latest version of this manual is available as Adobe Acrobat Reader (PDF) version only and can be downloaded from the Agilent Technolgies web page www.agilent.com. 1 1 Common: General Information This chapter provides general information about the 1050 Series of HPLC Modules Common: General Information Safety Information Safety Information The following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Agilent Technologies assumes no liability for the customer’s failure to comply with these requirements. General This is a Safety Class I instrument (provided with terminal for protective earthing) and has been manufactured and tested according to international safety standards. Operation Before applying power, comply with the installation section. Additionally the following must be observed. Do not remove instrument covers when operating. Before the instrument is switched on, all protective earth terminals, extension cords, auto-transformers, and devices connected to it must be connected to a protective earth via a ground socket. Any interruption of the protective earth grounding will cause a potential shock hazard that could result in serious personal injury. Whenever it is likely that the protection has been impaired, the instrument must be made inoperative and be secured against any intended operation. Make sure that only fuses with the required rated current and of the specified type (normal blow, time delay, and so on.) are used for replacement. The use of repaired fuses and the short-circuiting of fuseholders must be avoided. Some adjustments described in the manual, are made with power supplied to the instrument, and protective covers removed. Energy available at many points may, if contacted, result in personal injury. Any adjustment, maintenance, and repair of the opened instrument under voltage should be avoided as much as possible. When inevitable, this should be carried out by a skilled person who is aware of the hazard involved. Do not attempt internal service or adjustment unless another person, capable of 30 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: General Information Safety Information rendering first aid and resuscitation, is present. Do not replace components with power cable connected. Do not operate the instrument in the presence of flammable gases or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard. Do not install substitute parts or make any unauthorized modification to the instrument. Capacitors inside the instrument may still be charged, even though the instrument has been disconnected from its source of supply. Dangerous voltages, capable of causing serious personal injury, are present in this instrument. Use extreme caution when handling, testing and adjusting. When working with solvents please observe appropriate safety procedures (for example, goggles, safety gloves and protective clothing) as described in the material handling and safety data sheet by the solvent vendor, especially when toxic or hazardous solvents are used. Service Handbook for 1050 Series of HPLC Modules - 11/2001 31 Common: General Information Safety Information Safety Symbols Table 1 shows safety symbols that are used on the instrument and in the manuals. Table 1 Safety Symbols Symbol Description The apparatus is marked with this symbol when the user should refer to the instruction manual in order to prevent risk of harm to the operator and protect the apparatus against damage. Indicates dangerous voltages. Indicates a protected ground terminal. Eye damage may result from directly viewing the light produced by the deuterium lamp used in this product. Always turn off the deuterium lamp before opening the metal lamp door on the side of the instrument. WA R N I N G A warning alerts you to situations that could cause physical injury or damage to the equipment. Do not proceed beyond a warning until you have fully understood and met the indicated conditions. C A UT I O N A caution alerts you to situations that could cause a possible loss of data. Do not proceed beyond a caution until you have fully understood and met the indicated conditions. 32 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: General Information Radio Interference Radio Interference Manufacturer’s Declaration This is to certify that this equipment is in accordance with the Radio Interference Requirements of Directive FTZ 1046/1984. The German Bundespost was notified that this equipment was put into circulation, the right to check the series for compliance with the requirements was granted. Test and Measurement If test and measurement equipment is operated with equipment unscreened cables and/or used for measurements on open set-ups, the user has to assure that under operating conditions the radio interference limits are still met within the premises. Sound Emission Manufacturer’s Declaration This statement is provided to comply with the requirements of the German Sound Emission Directive of 18 January 1991. This product has a sound pressure emission (at the operator position) < 70 dB. • Sound Pressure Lp < 70 dB (A) • At Operator Position • Normal Operation • According to ISO 7779:1988/EN 27779/1991 (Type Test) Service Handbook for 1050 Series of HPLC Modules - 11/2001 33 Common: General Information UV-Radiation UV-Radiation Emissions of ultraviolet radiation (200-315 nm) from this product is limited such that radiant exposure incident upon the unprotected skin or eye of operator or service personnel is limited to the following TLVs (Threshold Limit Values) according to the American Conference of Governmental Industrial Hygienists: Table 2 UV-Radiation Limits Exposure/day Effective Irradiance 8 hours 0.1 µW/cm2 10 minutes 5.0 µW/cm2 Typically the radiation values are much smaller than these limits: Table 3 UV-Radiation Typical Values Position Effective Irradiance Lamp installed, 50-cm distance average 0.016 µW/cm2 Lamp installed, 50-cm distance maximum 0.14 µW/cm2 34 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: General Information Solvent Information Solvent Information Observe the following recommendations on the use of solvents. Flow Cell Long term operation at pH > 11 should be avoided. Never leave strongly alkaline solutions in the flow cell without flow. Solvents Always filter solvents through 0.4 µm filters, small particles can permanently block the capillaries. Avoid the use of the following steel-corrosive solvents: • Solutions of alkali halides and their respective acids (for example, lithium iodide, potassium chloride, and so on). • High concentrations of inorganic acids like sulfuric acid, especially at higher temperatures (replace, if your chromatography method allows, by phosphoric acid or phosphate buffer which are less corrosive against stainless steel). • Halogenated solvents or mixtures which form radicals and/or acids, for example: 2CHCl3 + O2 → 2COCl2 + 2HCl This reaction, in which stainless steel probably acts as a catalyst, occurs quickly with dried chloroform if the drying process removes the stabilizing alcohol. • Chromatographic grade ethers, which can contain peroxides (for example, THF, dioxane, di-isopropylether) such ethers should be filtered through dry aluminium oxide which adsorbs the peroxides. • Solutions of organic acids (acetic acid, formic acid, and so on) in organic solvents. For example, a 1-% solution of acetic acid in methanol may attack steel. • Mixtures of carbon tetrachloride with 2-propanol or THF dissolve stainless steel. Service Handbook for 1050 Series of HPLC Modules - 11/2001 35 Common: General Information 1050 Introduction 1050 Introduction The Modules Overview 1050 is a series of HPLC products based on a modular concept. The necessary functions are broken down into independent stand-alone modules with standardized external design hydraulic- and external interfaces. Following modules will be available at introduction: Table 4 1050 Modules Module Product Number 1050 Isocratic Pump 79851A 1050 Quaternary Pump 79852A 1050 Quaternary Pump (bio compatible) 79852B 1050 Variable Wavelength Detector 79853C 1050 Multiple Wavelength Detector 79854A 1050 Diode Array Detector G1306A 1050 Autosampler 79855A 1050 Autosampler (bio compatible) 79855B 36 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: General Information 1050 Introduction Figure 1 1050 Modules Service Handbook for 1050 Series of HPLC Modules - 11/2001 37 Common: General Information 1050 Introduction 1050 Identification Each module is identified by a 5 digit product number and a 10 unit serial number on a label attached to the wall inside the module. The first four digits of the serial number are the serial prefix. The letter identifies the country of origin. The last five digits are an identification number unique to each module. Any changes to the modules will be covered initially by Service Notes. They will be sent out to all Service personnel prior to implementation of the change to the instrument. With every reprint these changes will be incorporated into the documentation. Repair Policy Major mechanical and electrical assemblies inside the 1050 modules will be repaired on an assembly-exchange level. All other items have to be repaired on board/component level. Repair procedures are given in the respective sections of this manual (refer to Table of Contents). Assemblies can be set up to the Blue Stripe Exchange system or can be removed. If in doubt contact Waldbronn Product Support (Europe/ICON) or Little Falls Product Support (USA/Canada). 38 Service Handbook for 1050 Series of HPLC Modules - 11/2001 2 2 Common: Electronic Information This chapter provides common electronic information about the 1050 Series of HPLC Modules Common: Electronic Information This chapter gives information about the common electronics used in more than one of the 1050 Series of modules: • Overview • Common Main Processor (CMP) • Remote Control • Firmware Boards (FIM, SFW) • Fluorescent Indicator Module (FIP) • External Contacts • Poweer Supplies (DPS-B, DPS-A) • Communication Interfaces (CIB, CRB) 40 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Overview Overview Some of the electronic boards are used in more than one 1050 module. The following table shows common electronic assemblies: Table 5 Common Electronic Boards Description Modules Part Number Exchange Power Supply (DPS-B) pump, sampler 5061-3374 01050-69374 Power Supply (DPS-A) MWD, DAD, VWD 5061-3375 01050-69375 Common Main Processor (CMP) pump, sampler, MWD, DAD 5061-3380 01050-69580 Display Interface Board (FIP) pump, sampler, MWD, DAD 5061-3376 no Communication Interface (CIB) pump, sampler 5061-3382 no Communication Interface (CRB) MWD, DAD 5062-2482 no Service Handbook for 1050 Series of HPLC Modules - 11/2001 41 Common: Electronic Information Common Main Processor Board (CMP) Common Main Processor Board (CMP) Repair Level: Board Table 6 Part Numbers for CMP Board Item Part Number CMP Board (Exchange) 01050-69580 CMP Board (NEW) 5061-3380 Common 1050 Functions • display handling • keyboard polling • remote control input and output • leak sensing • option interfacing • time programming • method storage • module configuration • memory switching • 32 kbyte RAM with battery back-up for parameter storage. 42 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Common Main Processor Board (CMP) Figure 2 Blockdiagram CMP Service Handbook for 1050 Series of HPLC Modules - 11/2001 43 Common: Electronic Information Common Main Processor Board (CMP) According to the above functions the main processor board contains some basic hardware which is common to all 1050 modules: • 68008 main processor running at 8 MHz; • 64 kByte RAM (32 kbyte RAM with battery back-up for parameter storage. The data will be lost when CMP is removed from the slot); • interrupt logic for system communication; • 3 channel software controlled timer; • interface to keyboard/display module; • remote I/O hardware; • leak sensor electronics; • interface to backplane bus; • watchdog hardware. Firmware is not part of this board, because parts of the main processor’s software are module specific. The main processor firmware will be located on the ’personality module’ (AQB-, RAD, VMD-Board) or on an optional board. CMP Details Interrupt system There are one non-maskable interrupt six high priority hardware interrupt lines and seven low priority mail interrupt lines. The non-maskable interrupt is connected to the powerfail line of the power supplies (DPS-A/B). The high priority interrupt lines are: One from timer 6840 for hardware synchronization and five from remaining slots (these lines are disabled by SOK- = HIGH (system not ok). The low priority interrupt lines are: Five lines from all slots except power supply used for communication with local processors via dual port RAMs and two lines for CMP controlled software interrupts. Watchdog timer (Test for CPU hang-up) This circuitry is software retriggerable and is disabled during CPU initialization. In case of CPU hang-up SOK line is set the CPU is halted and the remote line ’shutdown’ is set. 44 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Common Main Processor Board (CMP) LED on board There is a RED LED on the board which is the output of the watchdog circuit. It is ON during initialization and when the processor has a hang-up (LD 101). Programmable timer It includes 3 independent timers: • Timer 1 is connected to the backplane bus it’s free for module special use. • Timer 2 is used as software timer for the CMP. • Timer 3 is used to generate the BUS ERROR signal. Reset system A harware reset is performed • at power • manually by on-board switch Hardware reset will reset all devices connected to the bus but main processor can reset these devices by software too. Reset for display unit The latch for the status LEDs and the brigthness control will not be reseted by power on or by software reset. The alphanumeric display is reseted at power on. I/O Two remote connectors are at the rear panel. They provide start, stop, not ready, shutdown, prepare-run and power on signals. The remote lines are input and output and are decoupled for EMC. The shutdown line is set by hardware in the case of leak or CPU hang-up. System control The POK (peripheral OK) is driven from all devices. The SOK- (system OK) • is outputted from main processor to all devices; • is hardware and software controlled • disables/enables all devices by main software; • disables all devices if main processor watchdog becomes active (main processor hang-up); Service Handbook for 1050 Series of HPLC Modules - 11/2001 45 Common: Electronic Information Common Main Processor Board (CMP) All devices are enabled after initialization. Bus control After bus request the main processor will pass bus control to the requesting external controller. The local main processor areas including I/O are accessible too. This may be a feature for diagnostics or if data rate is increasing to much with later options. For this second case an external fast transfer hardware (for example DMA device) could do the transfers after set-up by the main processor. Leak sensing The leak detection circuit is located on the CMP board and checks continuously for presence and leak conditions. If the sensor is missing (defect) or in leak condition the PTC is cooled down the error message appears. When the module is turned on the leak message is disabled for some time to allow the sensor to reach its working range. Working condition of the PTC Normal: about 75°C 400...500 Ohm Error: below 55°C about 150 Ohm Actions: ❏ Check for leak. ❏ Check connector of the sensor. ❏ Check resistance of leak sensor. ❏ Change leak sensor. ❏ Change CMP board. ❏ Change FIM board. 46 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Common Main Processor Board (CMP) Remote Control The CMP board provides two remote connectors. Remote control allows easy connection between single instruments or systems to ensure coordinated analysis with simple coupling requirements. When 1050 System is started from the autosampler the following signals can be measured at the remote lines. The START REQUEST signal is only available when the autosampler was started from any other module (remote configuration set to HPSystem). Figure 3 Remote Control Analysis Service Handbook for 1050 Series of HPLC Modules - 11/2001 47 Common: Electronic Information Common Main Processor Board (CMP) For the 1050 Series of HPLC Modules the subminiatur D connector is used. Each module provides two remote connectors which are both parallel and inputs/outputs (wired-or technique). To provide maximum safety within a distributed analysis system one line is dedicated to SHUT DOWN the system’s critical parts in case any module detects a serious problem. To detect whether all participating modules are switched on or properly powered one line is defined to summarize the POWER ON state of all connected modules. Control of analysis is maintained by signal readiness READY for next analysis followed by START of run and optional STOP of run triggered on the respective lines. In addition PREPARE and START REQUEST may be issued. Signal description SHUT DOWN (L) System has serious problem (e.g. leak: stops pump). Receiver is any module capable to reduce safety risk. POWER ON (H) All modules connected tosystem are switched on. Receiver is any module relying on operation of others. READY (H) System is ready for next analysis. Receiver is any sequence controller. PREPARE (L) Request to prepare for analysis (e.g. calibration detector lamp on). Receiver is any module performing preanalysis activities. START REQUEST (L) Request to start injection cycle (e.g. by start key on any module). Receiver is the autosampler. START (L) Request to start run / timetable. Receiver is any module performing runtime controlled activities. STOP (L) Request to reach system ready state as soon as possible (e.g. stop run abort or finish and stop injection). Receiver is any module performing runtime controlled activities. The signal level are defined as standard TTL levels (0 V is logic true, + 5 V is logic false). The remote lines can be input or output (wired or technique). • Fan-out is 10 • Input Load 2 kOhm against + 5 V • Outputs are open collector type 48 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Common Main Processor Board (CMP) The REMOTE Connector To help you make the correct connections the signals carried on each pin are listed in the table below (the colors refer to wires of remote cable 01046-60201). Figure 4 APG Remote Connector Table 7 Remote Signals Pin Signal Active Color 1 Digital ground 2 Prepare run LOW brown 3 Start LOW gray 4 Shut down LOW blue 5 Reserved 6 Power ON HIGH yellow 7 Ready HIGH red 8 Stop LOW green 9 Start request LOW black white pink Remote Configuration The 1050 Series provides three remote configurations: HPsystem Start of automatic operation from any modules’ start key. Start request is outputted. GLOBAL Synchronized start of several modules for a single run. Start / Stop is outputted. LOCAL Single modules’ start. No pulses outputted. Service Handbook for 1050 Series of HPLC Modules - 11/2001 49 Common: Electronic Information Common Main Processor Board (CMP) Figure 5 Table of line definition Notes • Y1 is done by balance key of MWD only. • Y2 BALANCE on detectors is performed. • Y3 is not used in the module. • The remote line SHUT DOWN will always be active. • The remote line POWER ON will not be processed. 50 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Common Main Processor Board (CMP) Figure 6 Schematic of Remote Control N OT E Above schematic is for Pump, Autosampler, MWD and DAD. The signal level are defined as standard TTL levels • (0 V is logic true, +5 V is logic false). • The remote lines can be input or output (wired or technique). • Fan-out is 10 • Input Load >=2.2 kOhm against + 5 V • Outputs are open collector type Service Handbook for 1050 Series of HPLC Modules - 11/2001 51 Common: Electronic Information Common Main Processor Board (CMP) Figure 7 Board Layout CMP 52 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Firmware Board (FIM) Firmware Board (FIM) Repair Level: Exchange Board Table 8 Part Numbers for Firmware Boards Item Part Number Exchange for Pumps (79851/2A/B) on RAD Board 01018-66518 no for Autosamplers (79855A/B) on VMD Board 01078-66504 no for Multiple Wavelength Detectors (79854A) on AQB Board 01048-66504 no for Diode ArrayDetectors (G1306A) on AQB Board G1306-66524 no Firmware Description Figure 3-7 shows the firmware structure for the 1050 Series of modules (pump, autosampler, multiple wavelength detector and diode array detector). As many as possible tasks use the same core firmware and only special routines for each module are developed seperate (control of the hardware sensors motors and so on). This common structure gives maximum flexibility for later development of similar products. It is obvious that also in the common firmware different commands display contents method parameters and so on. appear (Dialog, Method Handler, Parameter Handler). But nevertheless the structure is the same. In each part of the firmware there exist tables which hold the module specific commands parameters and so on, which are all handled under the same conditions. The firmware works with a foreground background mode. All time critical tasks (timetable execution, sensor and motor information) are working in the foreground mode and have highest priority. All other tasks share the remaining time in the background. If there are no tasks running the processor goes into the idle state. The firmware per module has approxmiately 300 kByte, where 170 kByte is Common and 130 kByte module specific). Service Handbook for 1050 Series of HPLC Modules - 11/2001 53 Common: Electronic Information Firmware Board (FIM) The firmware is located on the module specific firmware board which is piggy back on the personality board of each module (AQB-, RAD- or VMD-board) and can be exchanged easily. Figure 8 Firmware Structure 54 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Fluorescent Indicator Module (FIP) Fluorescent Indicator Module (FIP) Repair Level: Board or Fuse ICP1 Table 9 Part Numbers for FIP Board Item Part Number used for FIP Board 5061-3376 pumps, autosampler, MWD amd DAD Fuse 1 A 2110-0099 The FIP module is located behind the keyboard module of pump, autosampler and multiple wavelength detector. The function of the FIP module is to provide an interface between a host system and the user. Messages can be displayed with up to 32 characters (2 lines x 16 characters/line). A matrix keyboard is scanned for numeric or special function input and status information is displayed through 4 LEDs. The characters are displayed in a 5 x 7 dot matrix. In case of a dark display, check the on board fuse ICP1 (1 A) which is soldered in close to the connector P1/P2. Figure 9 Board Layout FIP Service Handbook for 1050 Series of HPLC Modules - 11/2001 55 Common: Electronic Information External Contacts External Contacts The personality boards of the 1050 modules (MWD/DAD: AQB, Pumps: RAD and Autosampler: VMD) have two external conacts at the rear. • 1 contact without supply (contact closure) <newline>max. 30 V/250 mA (fused with 250 mA) • 1 contact with internal 24 V supply (max. 250 mA output with fuse) The schematic for all three boards (AQB, NMD and RAD) is in general the same. Only the values of the components vary from board to board due to internal specifications. Figure 10 External Contacts Table 10 Components of External Contacts Components AQB RAD VMD L1, L2, L3, L4 4.7 µH 10 µH 1 µH C1, C2, C6, C7 100 nF 1 nF C3, C4, C8, C9 10 nF 10 nF C5, C10 1 nF 10 nF Fuse F250 mA (2110-0004) 56 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Power Supply (DPS-B / DPS-A) Power Supply (DPS-B / DPS-A) Repair Level: Fuses and DPS-B / DPS-A Table 11 Part Numbers for LUC/LPC Board Item Part Number used for DPS-B (Exchange) 01050-69374 Pumps and Autosamplers DPS-B (New) 5061-3374 Pumps and Autosamplers DPS-A (Exchange) 01050-69375 MWD, DAD, VWD DPS-A (New) 5061-3375 MWD, DAD, VWD Fuse for 110 V operation 3 A 2110-0003 Fuse for 220 V operation 2 A 2110-0002 General Description The power supply is a primary switching regulated type. It consists of two parts. the Base Supply and the Lamp Supply. The Base Supply provides outputs of +5 V, ±19 V, +24 V and +36 V. In addition the Lamp Supply provides all circuits necessary for the operation of a deuterium lamp. Service Handbook for 1050 Series of HPLC Modules - 11/2001 57 Common: Electronic Information Power Supply (DPS-B / DPS-A) Base Supply (DPS-B) Figure 11 on page 59 shows the base part of the DPS-A. The line voltage is rectified filtered and switched with about 50 kHz by a power MOS-FET. The complete control of frequency and pulsewidth is made by the control board #1 containing the logic needed and the FET driver. The isolation between the primary and the secondary part is made by opto-couplers and the switching transformer. The DC-output voltages are generated by single-phase rectifiers and LC-filtering with the additional features: The +36 V output has an separate over-voltage protection to limit the voltage to +45 V maximum. The +5 V output contains an additional analog series regulator to provide a stable output for all load conditions under different applications. The synchronization input is used in the 1050 MWD/DAD only to synchronize the switching frequency to a value of three times (54 kHz) of the diode array readout frequency. This output is not used in the other modules. The power supply status is monitored by the processor system to detect a powerfail condition and to save all important data. The Power Supply STATUS LED (GREEN) at the rear panel shows the OK condition of the power supply. N OT E OK means that the pulsewidth of the switching FET is inside the allowed limits. OK does not means that all voltages at the output are present (for example a broken inductor is not detected). 58 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Power Supply (DPS-B / DPS-A) Figure 11 Block Diagram DPS-B (Base Supply) Service Handbook for 1050 Series of HPLC Modules - 11/2001 59 Common: Electronic Information Power Supply (DPS-B / DPS-A) Lamp Supply (DPS-A) Figure 12 on page 61 and Figure 13 on page 62 show the additional circuits necessary for the deuterium lamp: • a DC output of 5.5 V for the regulated heater output (located on the primary board); • a regulated constant current source with selectable current of 320 mA, 360 mA or 400 mA; • a 600 V lamp ignition circuit; • a 12 V regulated output for future use. WA R N I N G Hazardous voltage present at the output connector with instrument power cord connected to AC line. The main feature of this power supply is a low noise current source for the deuterium lamp. For realization a pulse-width modulated DC-DC converter (36 V input, 170 V no load output) is built-up with a switching FET and high voltage transformer. The pulse-width is regulated so that the DC-output is about 12V above the actual anode voltage of the deuterium lamp. This design allows minimum power loss if the anode voltage varies from lamp to lamp and by aging between 65 V and 100 V. The final regulation to the selected current is made by an analog power regulator. Again the switching frequency is synchronized to 54 kHz in the 1050 MWD/DAD. 60 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Power Supply (DPS-B / DPS-A) Figure 12 Block Diagram DPS-A (Lamp Supply I) Service Handbook for 1050 Series of HPLC Modules - 11/2001 61 Common: Electronic Information Power Supply (DPS-B / DPS-A) Figure 13 Block Diagram DPS-A (Lamp Supply II) 62 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Power Supply (DPS-B / DPS-A) Lamp Ignition To ignite the deuterium lamp a 0.5 µF capacitor loaded with 600 V is discharged via a 10 kOhm resistor to the anode. These 600 V are generated by a separate winding. The lamp status output signal shows "OK" if the lamp current has the selected value. Otherwise an error message is generated. The heater output made by a series regulator is in the pre-heating status 2.5 V always. After ignition a different output voltage is selected depending on the lamp type used: In the 79853C VWD, 79854A MWD and the G1306A DAD, the heater is switched off after ignition. The 12 V low noise output is made by a series regulator connected to the +19 V output. Service Handbook for 1050 Series of HPLC Modules - 11/2001 63 Common: Electronic Information Communication Interface (CIB / CRB) Communication Interface (CIB / CRB) Repair Level: Exchange Board Table 12 N OT E Part Numbers for CRB Board Item Part Number used for CIB Board (NEW) 5061-3382 Pumps and Autosampler CRB Board (NEW) 5062-2482 79854A MWD / G1306A DAD This section describes the communication interface for the 1050 Pumps (79851/2A/B), Autosamplers (79855A/B), Multiple Wavelength Detectors (79854A) and Diode Array Detector (G1306A) only. The communication interface for the 1050 Variable Wavelength Detector (79853C) is described in the chapter of the 1050 VW Detector. The communication interface board is necessary for the control by a Personal Computer and to connect printer or plotter devices. The communication interface board provides one GPIB and one RS-232 interface. The CRB for the 1050 MWD/DAD has a 96 kbyte runbuffer for the data/spectrum operation with the Multiple Wavelength Detector. The interface is located in Slot #2 of the module. 64 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Electronic Information Communication Interface (CIB / CRB) Compatibilities Table 13 CIB/CRB Compatibility Instrument CIB CRB Firmware 1050 Pump R P REV 3.1 1050 Sampler R P REV 3.1 1050 MWD C R REV 3.1 1050 DAD C R REV 1.0 R recommended configuration P possible but not neccessary C only for instrument control Firmware To use the communication interface board it is mendatory to have the 1050 Modules equipped with the latest firmware revisions (see Table 13). Baud rate The board contains a baudrate generator. The baudrate is setable up to 19200 baud from the keyboard. The transmitter and receiver baudrate are independent adjustable. RS-232 Interface The implemented serial interface is a subset of the RS-232 standard only. It contains at PIN 2 RxD receive data (data input) PIN 3 TxD transmit data (data output) PIN 4 GND (Ground) The 1050 modules are designed as DCE (data communication equipment) without hardware handshake. Service Handbook for 1050 Series of HPLC Modules - 11/2001 65 Common: Electronic Information Communication Interface (CIB / CRB) 66 Service Handbook for 1050 Series of HPLC Modules - 11/2001 3 3 Common: Cable Information This chapter provides information on cables for the 1050 Modules Common: Cable Information Overview The 1050 Modules provide • Analog Signal Output (Pumps, Detectors) • Remote Control Connector (all) • BCD Connector (Autosampler) WA R N I N G Never use cables other than the ones supplied by Agilent Technologies to ensure proper functionality and compliance with safety or EMC regulations. 68 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Cable Information Overview Table 14 Cables Overview Type Description Part Number Analog cables 3390/2/3 integrators 01040-60101 3394/6 integrators, 35900A A/D converter 35900-60750 General purpose (spade lugs) 01046-60105 3390 integrator 01046-60203 3392/3 integrators 01046-60206 3394 integrator 01046-60210 3396A (Series I) integrator 03394-60600 Remote cables 3396 Series II / 3395A integrator, see page 74 BCD cables GP-IB cable 3396 Series III / 3395B/96C/97A integrator 03396-61010 1100 / 1050 modules / 1046A FLD / 35900A A/D converter 5061-3378 1040 DAD / 1090 liquid chromatographs / SDM 01046-60202 3392/3 integrators obsolete 3396 integrator 03396-60560 General purpose (spade lugs) 18594-60520 1100 module to ChemStation, 1 m 10833A 1100 module to ChemStation, 2 m 10833B 1100 module to ChemStation, 5 m 10833D Service Handbook for 1050 Series of HPLC Modules - 11/2001 69 Common: Cable Information Analog Cables Analog Cables One end of these cables provides a BNC connector to be connected to 1050 Series modules. The other end depends on the instrument to which connection is being made. 1050 to 3390/2/3 Integrators Connector 01040-60101 Pin 3390/2/3 Pin 1050 Signal Name 1 Shield Ground 2 3 Not connected Center 4 5 Signal + Connected to pin 6 Shield Analog - 6 Connected to pin 4 7 Key 8 Not connected 1050 to 3394/6 Integrators Connector 35900-60750 Pin 3394/6 Pin 1050 1 70 Signal Name Not connected 2 Shield Analog - 3 Center Analog + Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Cable Information Analog Cables 1050 to BNC Connector Connector 8120-1840 Pin BNC Pin 1050 Signal Name Shield Shield Analog - Center Center Analog + Pin 1050 Signal Name 1050 to General Purpose Connector 01046-60105 Pin 3394/6 1 Not connected 2 Black Analog - 3 Red Analog + Service Handbook for 1050 Series of HPLC Modules - 11/2001 71 Common: Cable Information Remote Cables Remote Cables One end of these cables provides a Agilent Technologies APG (Analytical Products Group) remote connector to be connected to 1050 Series modules. The other end depends on the instrument to be connected to. 1050 to 3390 Integrators Connector 01046-60203 72 Pin 3390 Pin 1050 Signal Name Active (TTL) 2 1 - White Digital ground NC 2 - Brown Prepare run Low 7 3 - Gray Start Low NC 4 - Blue Shut down Low NC 5 - Pink Not connected NC 6 - Yellow Power on High NC 7 - Red Ready High NC 8 - Green Stop Low NC 9 - Black Start request Low Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Cable Information Remote Cables 1050 to 3392/3 Integrators Connector 01046-60206 4 - Key Pin 3392/3 Pin 1050 Signal Name Active (TTL) 3 1 - White Digital ground NC 2 - Brown Prepare run Low 11 3 - Gray Start Low NC 4 - Blue Shut down Low NC 5 - Pink Not connected NC 6 - Yellow Power on High 9 7 - Red Ready High 1 8 - Green Stop Low NC 9 - Black Start request Low Pin 3394 Pin 1050 Signal Name Active (TTL) 9 1 - White Digital ground NC 2 - Brown Prepare run Low 3 3 - Gray Start Low NC 4 - Blue Shut down Low NC 5 - Pink Not connected NC 6 - Yellow Power on High 5,14 7 - Red Ready High 6 8 - Green Stop Low 1 9 - Black Start request Low 1050 to 3394 Integrators Connector 01046-60210 13, 15 N OT E Not connected START and STOP are connected via diodes to pin 3 of the the 3394 connector. Service Handbook for 1050 Series of HPLC Modules - 11/2001 73 Common: Cable Information Remote Cables 1050 to 3396A Integrators Connector 03394-60600 Pin 3394 Pin 1050 Signal Name 9 1 - White Digital ground NC 2 - Brown Prepare run Low 3 3 - Gray Start Low NC 4 - Blue Shut down Low NC 5 - Pink Not connected NC 6 - Yellow Power on High 5,14 7 - Red Ready High 1 8 - Green Stop Low NC 9 - Black Start request Low 13, 15 Active (TTL) Not connected 1050 to 3396 Series II / 3395A Integrators Use the cable 03394-60600 and cut pin #5 on the integrator side. Otherwise the integrator prints START; not ready. 74 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Cable Information Remote Cables 1050 to 3396 Series III / 3395B Integrators Connector 03396-61010 Pin 33XX Pin 1050 Signal Name 9 1 - White Digital ground NC 2 - Brown Prepare run Low 3 3 - Gray Start Low NC 4 - Blue Shut down Low NC 5 - Pink Not connected NC 6 - Yellow Power on High 14 7 - Red Ready High 4 8 - Green Stop Low NC 9 - Black Start request Low 13, 15 Active (TTL) Not connected 1050 to 1050, 1046A or 35900 A/D Converters Connector 5061-3378 Pin 1050 / … Pin 1050 Signal Name 1 - White 1 - White Digital ground 2 - Brown 2 - Brown Prepare run Low 3 - Gray 3 - Gray Start Low 4 - Blue 4 - Blue Shut down Low 5 - Pink 5 - Pink Not connected 6 - Yellow 6 - Yellow Power on High 7 - Red 7 - Red Ready High 8 - Green 8 - Green Stop Low 9 - Black 9 - Black Start request Low Service Handbook for 1050 Series of HPLC Modules - 11/2001 Active (TTL) 75 Common: Cable Information Remote Cables 1050 to 1090 LC, 1040 DAD or Signal Distribution Module Connector 01046-60202 5 - Key Pin 1090 Pin 1050 Active Signal Name (TTL) 1 1 - White Digital ground NC 2 - Brown Prepare run Low 4 3 - Gray Start Low 7 4 - Blue Shut down Low 8 5 - Pink Not connected NC 6 - Yellow Power on High 3 7 - Red Ready High 6 8 - Green Stop Low NC 9 - Black Start request Low Pin 1050 Signal Name Active (TTL) 1 - White Digital ground 2 - Brown Prepare run Low 3 - Gray Start Low 4 - Blue Shut down Low 5 - Pink Not connected 6 - Yellow Power on High 7 - Red Ready High 8 - Green Stop Low 9 - Black Start request Low 1050 to General Purpose Connector 01046-60201 76 Pin Universal Service Handbook for 1050 Series of HPLC Modules - 11/2001 Common: Cable Information BCD Cables BCD Cables One end of these cables provides a 15-pin BCD connector to be connected to the 1050 Series modules. The other end depends on the instrument to be connected to. 1050 to 3392/3 Integrators (Obsolete) Connector 18584-60510 6 - Key Pin 3392/3 Pin 1050 Signal Name BCD Digit 10 1 BCD 5 20 11 2 BCD 7 80 3 3 BCD 6 40 9 4 BCD 4 10 7 5 BCD 0 1 5 6 BCD 3 8 12 7 BCD 2 4 4 8 BCD 1 2 1 9 Digital ground 2 15 +5V Service Handbook for 1050 Series of HPLC Modules - 11/2001 Low 77 Common: Cable Information BCD Cables 1050 to 3396 Integrators Connector 03396-60560 Pin 3392/3 Pin 1050 Signal Name BCD Digit 1 1 BCD 5 20 2 2 BCD 7 80 3 3 BCD 6 40 4 4 BCD 4 10 5 5 BCD 0 1 6 6 BCD 3 8 7 7 BCD 2 4 8 8 BCD 1 2 9 9 Digital ground NC 15 +5V Low Wire Color Pin 1050 Signal Name BCD Digit Green 1 BCD 5 20 Violet 2 BCD 7 80 Blue 3 BCD 6 40 Yellow 4 BCD 4 10 Black 5 BCD 0 1 Orange 6 BCD 3 8 Red 7 BCD 2 4 Brown 8 BCD 1 2 Gray 9 Digital ground White 15 +5 Vt 1050 to General Purpose Connector 18594-60520 78 Low Service Handbook for 1050 Series of HPLC Modules - 11/2001 In This Book This manual contains technical information about the Agilent 1050 liquid chromatographs. This manual is available as electronic version (Adobe Acrobat Reader file) only. 1050 Series of HPLC Modules Service Handbook Pumps (79851A/79852A/B) Copyright Agilent Technologies 2001 All rights reserved. Reproduction, adaption, or translation without prior written permission is prohibited, except as allowed under the copyright laws. Part No. NONE 11/2001 Printed in Germany Warranty IMPORTANT NOTE The information contained in this document is subject to change without notice. This version of the 1050 service manual includes all sections from the 01050-90102 edition 4 (1995) and G1306-90102 edition 2 (May 1994). It merges both sections, the MWD and the DAD. Agilent Technologies makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties or merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Agilent Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn Germany The series I opticals information (79854A MWD) information has been removed (product went out of support during 2000). Part numbers have been updated as of 11/2001. Contact your local Agilent support office in case of part number issues or upgrades. The latest version of this manual is available as Adobe Acrobat Reader (PDF) version only and can be downloaded from the Agilent Technolgies web page www.agilent.com. 4 4 Pumps: General Information This chapter provides general information about the 1050 Pumps Pumps: General Information Introduction This chapter gives general information on • about this pump • repair policy • product structure • capillaries • specifications About this Manual This manual provides service information about the 1050 Pumps (isocratic and quaternary). The following sections give the detailed descriptions of all electronic and mechanical assemblies. You will find illustrated part-breakdowns interconnection tables connector configurations as well as all necessary replacement procedures in this manual. Detailed diagnostic procedures using firmware resident test methods and error messages are also given in this manual. 84 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: General Information About the Pumps About the Pumps The 1050 Pump modules houses the mechanical devices and the electronic circuitry for either the isocratic or quaternary module which control the various functions of the flow system. The module is controlled via the user interface through which the operator defines his requirements (flow-composition and so on) and which provides the required analytical information. Repair Policy The 1050 Pumps are designed that all components are easy accessible Customers are able to repair certain parts of the 1050 Pumps see Operator’s Handbook. For details on repair policy refer to “Repair Policy” on page 38. Service Handbook for 1050 Series of HPLC Modules - 11/2001 85 Pumps: General Information Product Structure Product Structure The 1050 Series of HPLC modules are available in two versions. In the standard version most of the parts used are stainless steel. In the 1050 Ti Series the flow path of the quaternary pump consists solely of corrosion resistant materials such as titanium, tantalum, quartz, sapphire, ruby, ceramic and fluorocarbon polymers. It is recommended for use with mobile phases containing high salt concentrations, extreme pH solutions and other aggressive mobile phases. N OT E Isocratic Pump 79851A Quaternary Pump 79852A Ti - Quaternary Pump 79852B The isocratic pump was also introduced as Ti - version (79851B) but due to the insufficient orders it became obsolete end of FY 91. 86 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: General Information Capillaries Capillaries In the 1050 Pumps the capillary shipped with the module will have a plastic color coating for identification in terms of material and internal diameter. All capillaries before the injector have a internal diameter of 0.25 mm. From the injector the internal diameter is reduced to 0.17 mm. Table 15 Capillary Color Code color Internal Diameter blue 0.25 mm green 0.17 mm red 0.12 mm white N OT E Material tantalum For the Ti pumps the fittings are always titanium with a titanium nitrite coating and the front and back ferrules are gold plated. The Ti capillaries have two color coatings. One for identifying the material covering the main part of the capillary and a small one for the internal diameter. Service Handbook for 1050 Series of HPLC Modules - 11/2001 87 Pumps: General Information Specifications Specifications Table 16 Specifications of 1050 Pumps Hydraulic System Dual-pistons in-series with proprietary servo-controlled variable stroke drive floating pistons and active inlet valve. Flow Range Setpoint from 0.001 to 9.999 ml/min in 0.001 ml/min increments. Piston Displacement 20 to 100 µl, automatic matched to flow rate or user-selectable. Flow Precision <0.3% RSD (typically <0.15%) based on retention time at 0.5 ml/min and 2.5 ml/min. Pressure Operating range from 0-400 bar (5880 psi) up to 5 ml/min; from 0-200 bar (2950 psi) up to 10 ml/min. Display in bar, psi or MPa. Pressure Pulsation <2% amplitude (typically <1%), 1 ml/min isopropanol at all pressures >10 bar. Compressibility Compensation User-selectable, based on mobile phase compressibility. Recommended pH Range 2.3 to 12.5 (stainless steel version). Solvents with pH below 2.3 should not contain acids which attack stainless steel. 1.0 to 14 (TI series). Gradient Formation Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay Volume 900 to 1100 µl dependent on back pressure. Composition Range 0 to 100% in 0.1% increments from four independent channels. Composition Precision ±0.25% absolute (typically ±0.15%) peak to peak, binary mixed water/acetonitrile from 0.5 ml/min to 5.0 ml/min without mixer. Solvent Preparation Four 1 liter bottles each with individually-regulated helium sparger, cap and filter. 88 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: General Information Specifications Table 16 Specifications of 1050 Pumps Oven Temperature Range Ambient +5°C to ambient +60°C in 0.1°C increments.Display in °C, °F or K. Oven Temperature Stability ±0.15°C Oven Capacity Two 25-cm or three 20-cm columns. Control Integrated keyboard with function keys; parameter editing during run possible; keyboard lock; optional control by PC. Parameters Flow rate, compressibility, stroke volume, upper and lower pressure limits, 2 external contacts; %B, %C, %D (for quaternary pump). Time-programmable Parameters: Flow rate, upper pressure limit, external contacts; %B, %C, %D. Methods Battery-backed storage of up to 10 methods. Automatic start up and shut down methods. Editing of stored methods possible in run. Analog Output For pressure monitoring, 2 mV/bar. Communications Outputs: ready signal and two external outputs (one 24 V relay and one 30V (AC/DC) contact closure, both with 0.25 A. In-and outputs: start, stop and shut down signals. Optional interface for GPIB and RS-232C. Safety Aids Extensive diagnostics, error detection and display via front-panel LED's and status logbook. User-definable shutdown method activated in case of error. Leak detection and safe leak handling. Low voltages in major maintenance areas. Column pressure protection with maximum rate of pressure change of <20 bar/sec after a setpoint change. Environment 4°C to 55°C (constant temperature) with <95% humidity (non-condensing). Power Requirements Line voltage: 100-120 or 220-240 VAC ±10% Line frequency: 48-66 Hz Power consumption: 120 VA max. Service Handbook for 1050 Series of HPLC Modules - 11/2001 89 Pumps: General Information Specifications Table 16 Specifications of 1050 Pumps Dimensions Height: 208 mm (8.2 in) Width: 325 mm (12.8 in) Depth: 560 mm (22.0 in) For complete description of test conditions used to obtain specifications, see Owner’s Manual. 90 Service Handbook for 1050 Series of HPLC Modules - 11/2001 5 5 Pumps: Hardware Information This chapter provides hardware information about the 1050 Pumps Pumps: Hardware Information This chapter gives general and technical information about the hardware components of the 1050 Pumps. • Solvent Cabinet • Pump Hardware ❏ Multi Channel Gradient Valve (MCGV) ❏ Metering Drive Assembly ❏ Pump Head Assembly ❏ Continuous Seal Wash ❏ Active Inlet Valve ❏ Outlet Ball Valve ❏ Frit Adapter Assembly ❏ Purge Valve ❏ High Pressure Damper • Column Holder 92 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Hardware Information Overview Overview The 1050 Pump is based on a dual piston series design which comprises all essential functions a solvent delivery system has to fulfill. Metering of solvent and delivery to the high pressure side are performed by one metering assembly which can generate pressure up to 400 bar. The basic system (isocratic) comprises the metering assembly including an active inlet valve, an outlet valve, a frit adapter assembly and a damping unit. The gradient operation system includes a highs peed proportioning valve allowing quaternary operation and a solvent cabinet with separate Helium degassing for each solvent channel. Since the introduction of the G1303A Online Degasser (December 1,1991) the Helium degassing might be replaced by the degasser module. A purge valve is installed on the pump head for convenient priming of the pump. An continuous seal wash is available when the pump is used with buffer solutions. It is mandatory in the Ti - pump and can be ordered as an option for the standard version. The solvent cabinet for the 1050 Pumps can be equipped with a manual injection valve and a column heater. Service Handbook for 1050 Series of HPLC Modules - 11/2001 93 Pumps: Hardware Information Overview Figure 14 Overview Pump System 94 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Hardware Information How does the Pump Work? How does the Pump Work? The metering assembly comprises two substantially identical piston pump units. Both pump units comprise a ball screw drive and a pump head with a sapphire piston for reciprocating movement in it. The servo controlled variable reluctance motor drives the two ball drive screws in opposite direction. The gears for the ball screw drives have different circumferences (ratio 2:1) allowing the first piston to move double the stroke length of the second piston. The solvent enters the pump heads close to the bottom limit and leaves it at its top. The outer diameter of the piston is smaller than the inner diameter of the pump head chamber allowing the solvent to fill the gap in between. The first piston has a stroke volume in the range of 20 µl to 100 µl depending on the flow rate. The microprocessor controls all flow rates in a range of 1 µl to 10 ml. The inlet of the first pumping unit is connected to the active inlet valve which is processor controlled opened or closed allowing solvent to be sucked into the first pump unit. The outlet of the first pump unit is connected via the outlet ball valve and the damping unit to the inlet of the second pump unit. The outlet of the metering assembly is than connected to the following chromatographic system. Isocratic Operation When turned on the pump runs through a initialization procedure to determine the upper dead center of the first piston. The first piston moves slowly upwards into the mechanical stop of the pump head and from there it moves back a predetermined path length. The controller stores this piston position in memory. After this initialization the pump starts operation with the set parameters. The active inlet valve is opened and the down moving piston draws solvent into the first pump head. At the same time the second piston is moving upwards delivering into the system. After a controller defined stroke length (depending on the flow rate) the drive motor is stopped and the active inlet valve is closed. The motor direction is reversed and moves the first piston up until it reaches the stored upper limit and at the same time moving the second piston downwards. Then the sequence starts again moving the pistons up and down between the two limits. Service Handbook for 1050 Series of HPLC Modules - 11/2001 95 Pumps: Hardware Information Overview of the Electronics During the up movement of the first piston the solvent in the pump head is pressed through the outlet ball valve and the damping unit into the second pumping unit. The second piston draws in half of the volume displaced by the first piston and the remaining half volume is directly delivered into the system. During the drawing stroke of the first piston the second piston delivers the drawn volume into the system. Gradient Operation For gradient operation the multi channel gradient valve (MCGV) connected to solvent containers A, B, C and D is required. The controller makes sure that each intake stroke of the first piston contains the required solvent composition. The controller divides the length of the intake stroke in certain fractions in which the MCGV connects the specified solvent channel to the pump input. Overview of the Electronics The figure 2-2 shows the block diagram of the 1050 Pumps including all currently available options. The common main processor (CMP) controls all functions of the modules. The controller firmware is attached to the relative A/D converter board (RAD). The column heater can be installed into the solvent cabinet. The electronic control is done via the pump module. Two different boards will be available for supporting the column heater in either the isocratic pump (79851A) or the quaternary pump (79852A/B). For the quaternary pump (79852A/B) the heater quaternary board (HRQ) controls the column heater and drives the multi channel gradient valve (MCGV). For the isocratic pump (79851A) the heater isocratic board (HRI) controls only the column heater. The HRI board is a subtract of the HRQ Board; the blank board is identical but the components for the gradient operation are not mounted. 96 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Hardware Information Overview of the Electronics The communication interface board (CIB) provides an GPIB and RS232C interface. With the CIB installed the pump can be controlled via the ChemStation or via the 3396B integrator. Figure 15 Block Diagram 1050 Pumps Service Handbook for 1050 Series of HPLC Modules - 11/2001 97 Pumps: Hardware Information Overview of the Flow Path Overview of the Flow Path From the bottle head assembly (tube #1) the solvent moves via the gradient valve (MCGV), the connection tube #2 and the active inlet valve into the pump. From the outlet ball valve the capillary #3 is connected to the damper and from there the solvent streams back to the second piston chamber (capillary #4). The standard interface capillary #5 (70 cm long 0.25 mm ID) connects the pump to the next module (for example the autosampler). In the isocratic pump the solvent sucking tube #2 is directly connected to the solvent bottle and the interface capillary (#5) is connected to the frit adapter. In the quaternary pump the interface capillary (#5) is connected to a purge valve. The purge valve allows convenient priming of the system. When opened the flow is directed via tubing (#7) in to the waste. The typical delay volume for the pump is in the range 900 to 1100 µl (depending on system back pressure). If the seal wash accessory is installed the wash bottle on top of the instrument (tube #6) is connected to the two support rings for back flushing of the piston seals. From the second support ring the wash solvent flows into the collecting vessel. Figure 16 Hydraulic Path 98 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Hardware Information Solvent Cabinet Solvent Cabinet Repair Level: Component Table 17 Product Numbers for Solvent Cabinet Item Part Number Solvent Cabinet 79856A Ti - Solvent Cabinet 79856B The solvent cabinet allows storage of 4 four 1 liter solvent bottles. It is designed to hold the following options: • Helium degassing; later it was replaced by 1050 online degassing • Manual injection valve • Column Heater • Manual injection valve and column heater Helium Degassing N OT E For low pressure mixing degassing is a must. Therefore the Helium degassing or the Online Degasser G1303A is mandatory for the quaternary pump. If the Helium degassing is selected a internal tubing guides the Helium from the back of the solvent cabinet to an on/off valve and from there to four regulators. Each of the regulator supplies helium to one bottle head assembly for separate sparging of each bottle. The bottle head assembly consists of a sintered glass sparger, stainless steel or titanium filter and a cap with vent position. It is designed for the provided standard bottle, but allows also operation with supply bottles from certain vendors. The bottle head assembly has also a connection for a fume hood tubing (see also “Helium Degassing Principle” on page 269). Service Handbook for 1050 Series of HPLC Modules - 11/2001 99 Pumps: Hardware Information Solvent Cabinet N OT E The connected helium pressure has to be in the range 2 to 4 bar (30 to 60 psi). With pressures below 2 bar the helium degassing system may not work correctly. Pressure above 4 bar might damage the helium regulators. Manual Injection Valve If ordered with manual injection valve a Rheodyne 7125 valve with 20 µl loop will be installed in the solvent cabinet. If ordered as a Ti version a Rheodyne 7125 titanium valve with Tefzel rotor seal will be present in the cabinet. A remote-start output is available at the back of the cabinet. Column Heater The column heater fits into the recess of the cabinet. Electronic control is done via the pump module. The column heater can hold up to 25 cm long columns. The flow path of the column heater is stainless steel even in the Ti version. The heater uses a heating foil which is attached to a aluminum heating block where the solvent capillaries are leading through (heat exchanger). The column rests in the U-shaped heat exchanger. When turned on, the heat exchanger will heat up the solvent, the column and the surrounding air in the compartment. Temperature is monitored on the heating block via a Pt. 100. A multi (3) color LED shows the actual status of the column heater. The power consumption of the heater is reduced by heat recycling. Incoming and outgoing capillaries of the heat exchanger are in close thermal contact allowing radial heat exchange while the solvent is streaming through. 100 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Hardware Information Solvent Cabinet Figure 17 Solvent Cabinet including all options Service Handbook for 1050 Series of HPLC Modules - 11/2001 101 Pumps: Hardware Information Multi Channel Gradient Valve (MCGV) Multi Channel Gradient Valve (MCGV) Repair Level: Exchange Assembly Table 18 Part Numbers MCGV Item Part Number Exchange MCGV 79835-67701 79835-69701 Ti - MCGV 01019-67701 The multi channel gradient valve (MCGV) works like a multi position switch. Depending on the timing of the control electronic the Heater Quaternary Board (HRQ) activates one of the four solenoids connecting the selected channel to the output of the valve. In the Ti-version of the gradient valve only the materials have been changed. Table 19 Technical Data of MCGV Switching Time: approximately 2 ms Solenoid Voltage: +12 V (+36 V Chopper Drive) Ti Series Materials in contact with solvent: Figure 18 PFA, PTFE, sapphire, ruby, ceramic, Titanium MCGV 102 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Hardware Information Metering Drive Assembly Metering Drive Assembly Repair Level: Exchange Assembly Table 20 Part Numbers Metering Drive Assembly Item Part Number Exchange Metering Drive Assembly 01018-60001 01018-69100 The metering drive assembly is identical for the stainless steel and the Ti version. The metering pump system is driven by a variable reluctance motor (servo) and electrically controlled by the Pump Drive Control Board (PDC). Feedback about actual movement is sensed by a shaft encoder mounted on top of the motor. In order to achieve required flow resolution a gear is used to transmit motor movement to the two pistons. The gears for the ball screw drives have different circumferences (ratio 2:1) allowing the first piston a twice as large stroke volume as the second piston. The second piston operates with a fixed 180° difference relative to the first piston. A sensor on the motor surface checks for over temperature conditions (90°C). Table 21 Figure 19 Technical Data of Metering Drive Resolution of mechanical system: 6.6 nl/steps of Encoder Resolution of Encoder: 0.25 degree Lowest Frequencies: 2.5 Hz Highest Frequencies: 25 KHz Number of steps between piston extension limits: 8191 Metering Drive Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 103 Pumps: Hardware Information Pump Head Assembly Pump Head Assembly Repair Level: Component Table 22 Part Numbers Pump Head Assembly Item Part Number Pump Head Assembly 01018-60004 Ti - Pump Head Assembly 01019-60002 Two identical piston move inside the solvent filled chamber in the pump head assembly. The piston are ball loaded on the spindles and center itself in the seal. The built in spring prevents clearances of the plunger affecting flow accuracy (see also “Pump Head Assembly” on page 271). Table 23 Technical Data of Pump Head Maximum displacement volume: 108 µl Ti - Series Materials in contact with solvents Figure 20 titanium, gold, sapphire, ceramic Pump Head Assembly 104 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Hardware Information Continuous Seal Wash Continuous Seal Wash Repair Level: Component Table 24 Part Numbers Seal Wash Item Part Number Seal Wash Kit 01018-68722 Velocity regulator 3/pk 5062-2486 Bioscience application do very often use high concentrated buffer solutions. Therefore the seal wash is installed in each Ti pump. For the stainless steel version it is available as an option and should be used when buffer solutions are used in the instrument. If high buffer concentration are used in the pump the continuous seal wash will maintain the life time of the pump seal. Buffer solutions below 0.1mol normally do not require the seal wash option. The option is customer installable. The option consists of a support ring (1) a secondary seal (2) and a gasket (3) for both piston sides. A wash bottle filled with water/isopropanol (90/10) will be placed above the pump module and gravity will maintain a flow through the pump head removing all possible buffer crystals from the back of the pump seal. N OT E Running dry is the worst case for a seal and drastically reduces the life time of it. Therefore the tubings of the wash option should always be filled with solvent to maintain the life time of the wash seal. Use always a mixture of distilled water (90%) and isopropanol (10%) as wash solvent. The mixture prevents bacteria growth in the wash bottle and reduces also the surface tension of the water. The flow rate should be regulated to approximately 20 drops/minute (velocity regulator 5062-2486). Service Handbook for 1050 Series of HPLC Modules - 11/2001 105 Pumps: Hardware Information Continuous Seal Wash Figure 21 Continuous Seal Wash 106 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Hardware Information Active Inlet Valve Active Inlet Valve Repair Level: Assembly Table 25 Part Numbers Active Inlet Valve Item Part Number Active Inlet Valve 01018-60010 Ti - Active Inlet Valve 01019-60010 The active inlet valve is a solenoid driven check valve. In the Ti version all parts in contact with solvents are corrosion resistant. The solenoid is controlled by the Pump Drive Control Board (PDC). A spring loaded ruby ball sitting in a sapphire seat closes or opens the flow path. If the solenoid is deactivated the keeper of the magnet presses the ruby ball down opening the flow path. At the same time the down moving first piston draws solvent into the pump head. The activated solenoid enables the spring to press the ruby ball in its seat and the flow path is blocked. Older versions do have a solvent protection cover installed. Table 26 Ti - Series Materials in contact with solvents Figure 22 titanium, gold, sapphire, ceramic, Active Inlet Valve Service Handbook for 1050 Series of HPLC Modules - 11/2001 107 Pumps: Hardware Information Outlet Ball Valve Outlet Ball Valve Repair Level: Assembly Table 27 Part Numbers Outlet Ball Valve Item Part Number Outlet Ball Valve G1311-60012 The outlet ball valve is made of corrosion resistant materials and can be used in both pump versions. The outlet valve cartridge contains two seat / ball pairs with the necessary seals. A slight weight on top of each ball limits the movement of the ball and maintains a small delay volume. The cartridge (3) is fixed with adhesive and the valve will be damaged if opened. The valve should always be tightened at the housing screw (2) and never at the cartridge (3) itself. Table 28 Ti - Series Materials in contact with solvents Figure 23 titanium, gold, ruby, sapphire Outlet Ball Valve 108 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Hardware Information Frit Adapter Assembly Frit Adapter Assembly !Repair Level: Component Table 29 Part Numbers Seal Wash Item Part Number Frit Adapter Assembly 01018-60007 The housing of the frit adapter assembly is made from titanium and is suitable for both pump versions. The frit adapter assembly is installed in each isocratic pump. It is the interface to the following system components (for example autosampler) and holds a PTFE frit. The capacity of the frit when installed correctly is large enough to collect all the particles during the normal life time of the piston seal. It is recommended to replace the frit each time the seal has to be replaced as part of the normal pump maintenance. The second criteria for replacing the frit is the pressure across over it. If the pressure drop is more then approximately 10 bar with 5ml/min H2O the frit should be changed. Table 30 Ti - Series Materials in contact with solvents Figure 24 Titanium, PTFE, gold Frit Adapter Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 109 Pumps: Hardware Information Purge Valve Purge Valve Repair Level:Assembly except of PTFE frit and gold seal (item 1 to 3) Table 31 Part Numbers Purge Valve Item Part Number Purge Valve (replacement) G1311-60009 Purge Valve Update Kit 01018-68723 The purge valve was introduced in November 1990. The purge valve is made from corrosion resistant materials and is suitable for both pump versions. The purge valve will be installed on all quaternary pumps and can be ordered as an option to the isocratic pump. The lower part of the purge valve is designed like the frit adapter assembly and holds the PTFE frit. A ball seat combination builds the purge valve. When opened at the thumb screw the ball is lifted out of its seat allowing the solvent to flow through the waste outlet. When the thumbscrew is turned down the internal springs press the ball into the seat. Flow is directed to the following system components. Table 32 Ti - Series Materials in contact with solvents Figure 25 Titanium, PTFE, gold, ceramic Purge Valve Assembly 110 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Hardware Information High Pressure Damper High Pressure Damper Repair Level:Assembly Table 33 Part Numbers High Pressure Damper Item Part Number Damper 79835-60005 Ti - Damper 01019-60005 For the Ti version of the high pressure damper all parts which are in contact with solvents are gold plated. Two functions are obtained from the High Pressure Damper. Flow is damped (flow ripple reduction) and the pressure in the system is measured. The damping function is provided by an aluminum housing partly filled with water as the compressible medium and a solid steel block (3) which compensates for different coefficients of expansion of water and the aluminum housing. A protection plate (2) mounted between cover and housing prevents membrane (1) damage resulting from pressure excess or pressure shocks. Pressure is measured with a pressure transducer. The electrical circuit that outputs a voltage proportional to the pressure measured is mounted directly to the pressure transducer. Table 34 Ti - Series Materials in contact with solvents Figure 26 gold High Pressure Damper Service Handbook for 1050 Series of HPLC Modules - 11/2001 111 Pumps: Hardware Information Column Holder Column Holder Repair Level:Assembly Table 35 Part Numbers High Pressure Damper Item Part Number Column Holder Assembly 5062-2469 The column holder is standard for the 1050 Ti Pumps. It is designed for use with any of the 1050 Series modules either separately or in a stack. A 1050 module will fit onto the column holder base (1) and the stand (2) can be used to attach columns which do not fit into the solvent module compartment using the clamp (3). Possible leaks will be collected in the groove (5). The support block (4) maintains the correct height adjustment of the autosampler foot support (100 vial tray). WA R N I N G The column holder is not intended for use with solvents which are flammable or toxic. If such solvents are used you must use a leak tray or equivalent. You must also position the column so that any leaking solvent is collected by the leak tray. Figure 27 Column Holder 112 Service Handbook for 1050 Series of HPLC Modules - 11/2001 6 6 Pumps: Electronic Information This chapter provides electronic information about the 1050 Pumps Pumps: Electronic Information • This chapter gives information about the electronic of the pumps: • Overview • Pump Drive Control Board (PDC) • Relative A/D Converter Board (RAD) • Firmware Board (SWF) • Heater Isocratic Board (HRI) • Heater Quaternary Board (HRQ) • High Pressure Transducer Board (HPT) • Connector Board (CON) • Pump Motherboard (HPS) 114 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information Overview Overview All electronic boards (except the FIP, behind the keyboard and the CON, above the MCGV) are located in the rear part of the module and they are connected to the Motherboard (HPS). Excess to the boards is from the back of the instrument. Slot numbers for the boards (as shown in the status screen) are counted from left to right. The power supply board is located in slot 1 and the common main processor is located in slot 7. In the 1050 pumps the following electronic assemblies are available: Table 36 N OT E Electronic Boards Description Part Number Exchange Power Supply (DPS-B) 5061-3374 01050-69374 Common Main Processor (CMP) 5061-3380 01050-69580 Pump Drive Control (PDC2) 01018-66532 Relative A/D Converter (RAD) 01018-66503 Firmware Board (SFW) 01018-66506 Heater Isocratic Board (HRI) 01018-66517 Heater Quaternary Board (HRQ) 01018-66518 Connector Board (CON) 01018-66505 Motherboard (HPS) 01018-66501 Display Interface Board (FIP) 5061-3376 Communication Interface (CIB) 5061-2482 01018-69503 01018-69518 For information about Power Supply, Common Processor and Fluorescent Interface refer to “Common: Electronic Information” on page 39. Service Handbook for 1050 Series of HPLC Modules - 11/2001 115 Pumps: Electronic Information Overview Figure 28 Rear of 1050 Pumps 116 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information Overview Figure 29 Block Diagram 1050 Pumps Service Handbook for 1050 Series of HPLC Modules - 11/2001 117 Pumps: Electronic Information Pump Drive Control Board (PDC2) Pump Drive Control Board (PDC2) Repair Level: Board, Fuses and U78, U79 Table 37 Part Numbers for ASC Board Item Part Number PDC2 01018-66532 PDC replaced by PDC2 Fuse: F16 (PDC), F481 (PDC2) 1.5 A 2110-0304 Fuse F891, F892 (PDC); F112, F113 (PDC2) on board 500 mA 2110-0934 U78 (MC78L15ACP) 1826-0274 U79 (MC79L15ACP) 1826-0281 The main functions of the PDC board are the control of the pump motor and the active inlet valve. For the quaternary system the PDC board has also to generate the control signals for the gradient valve circuit on the Heater Quaternary Board (HRQ). The PDC2 board succeeds the PDC board. For standardization and cost reduction reasons part of the circuit has been implemented in ASIC (Application Specific Integrated Circuit). The board size was reduced the board is also used in the other APG products and a stainless steel plate extends the board to 1050 board size. Fuses Fuse F16 (PDC) or F481 (PDC2) (1.5 A) protects the +36 V for servo motor and active inlet valve for overcurrent conditions on the old PDC board. F891 (PDC) or F113 (PDC2) (500 mA) protects the active inlet valve for overcurrent conditions while F892 (PDC) or F112 (PDC2) is for future use (space for additional connector on CON board). 118 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information Pump Drive Control Board (PDC2) Figure 30 Block Diagram PDC2 Board Service Handbook for 1050 Series of HPLC Modules - 11/2001 119 Pumps: Electronic Information Pump Drive Control Board (PDC2) U78, U79 PDC Boards revision A need an replacement of U78 and U79 when the metering drive (01018-69100) of the instrument has to be changed. Clock Generator The clock generator provides the clocks for the different pump boards. The pump control chip needs the 2 MHz clock and the pump control logic on the Relative A/D Board (RAD) and the Gradient Valve Driver Board (GVD) need the 1 MHz clock. Filter and Logic The filter and logic circuit disables the operation of the control chip in case of malfunctions in the system. Input signals for the block is the system OK (SOK) signal from the common main processor (CMP) which is active when the processor has locked up. The second signal connected to the circuit comes from the over temperature sensor on the surface of the pump motor. The TOK signal is active when the motor temperature exceeds 90°C. 12 V Check The +12 V voltage will be checked for under voltage conditions. In case the voltages drops below approximately +10 V a proper working of the pump is no longer possible and the pump control chip will be disabled. Pump Control Chip The pump control chip is the brain of the PDC board. It handles all time critical and time consuming tasks for the digital position control of the pumping system. The chip works independent from the processor which supplies only the pump parameters (for example flow, stroke, compensation, gradient information and so on). All parameter changes will be transferred directly to the pump control chip. The feedback from the motor comes to the chip via the shaft encoder and allows accurate control of the motor (speed, direction and so on). The control chip sends the signals for the motor driver to energize the various motor windings. The control chip influences the current through the motor windings by changing the pulse width and by an amplification factor (Gain). The actual value of the current is supplied by the current amplifier and comparator circuit. 120 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information Pump Drive Control Board (PDC2) The active inlet valve gets its control signals from the control chip. The optional gradient valve driver board (GVD), which controls the MCGV works under the supervision of the control chip. Motor Driver The motor driver circuit block contains the power stages for the motor. The motor is a three phase variable reluctance motor. Current Amplifier and Comparator One task of this circuit block is to measure the current through all the windings and to feed this signal into the control chip. From the control chip the circuit gets the pulse width (PW) and gain (GA) signals. With the pulse width the current value through the windings is determined. If the gain signal is active the amplifier multiplies the current with a factor (1.4). This is necessary to assure a constant torque at all motor positions. Active Inlet Valve The control chip provides the signals to activate or deactivate the active inlet valve. Figure 31 shows the control signal from the control chip and the current in the solenoid valve. The high current allows fast switching of the valve while the holding current reduces the heat dissipation of the solenoid. Figure 31 Inlet Valve Control Service Handbook for 1050 Series of HPLC Modules - 11/2001 121 Pumps: Electronic Information Pump Drive Control Board (PDC2) Figure 32 Board Layout PDC 122 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information Relative A/D Converter Board (RAD) Relative A/D Converter Board (RAD) Repair Level: Exchange Board or Fuses Table 38 Part Numbers for ASC Board Item Part Number Exchange RAD 01018-66503 01018-69503 Fuse: F12, F22, 250 mA 2110-0004 The main function of the board is the relative A/D conversion with an analog pressure output and overpressure measurement for the flow reduction. In addition the RAD board controls the two external contacts and checks for the status of active inlet valve and motor temperature. The firmware board (SFW) which contains the module firmware is attached to the RAD board and is used by the common main processor (CMP). Control Logic The control logic synchronizes the communication between the RAD and the main processor. Status Register The status register sends information about board identification motor temperature and active inlet valve to the main processor. Via the board identification the main processor identifies the board in the card cage. In case of a wrong board position the processor does not allow signals to the board. The over temperature sensor on the pump motor surface generates an error message when the motor temperature exceeds 90°C (fan defective?). If the active inlet valve is not connected an error message is generated (when pump will be turned on) and the operation of the pump is inhibited. Service Handbook for 1050 Series of HPLC Modules - 11/2001 123 Pumps: Electronic Information Relative A/D Converter Board (RAD) Figure 33 Block Diagram RAD 124 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information Relative A/D Converter Board (RAD) Relay Contact Register The relay contact register activates the two relay contact circuits on request of the processor. When activated contact 1 provides fused (250 mA) +24 V while contact 2 provides a fused (250 mA) 30 V (AC/DC) rated contact closure. For more technical information about the relay contacts see “External Contacts” on page 56. Relative A/D Conversion The relative A/D conversion consist of a A/D converter a D/A converter with differential amplifier and a divider and filter. In addition a filter and amplifier for the pressure signal is needed and a comparator for the overpressure signal. The relative A/D converter delivers a binary data word which is independent from the absolute value of the signal. The output data word shows the % difference of the actual value compared to a reference value. The 8 bit D/A converter and the differential amplifier provide the reference voltage URef. The dynamic range for the relative measurement represents ±6.4% of the absolute value of the signal. The divider and filter stage determines the Reference signal which is Ref=URef x 12.8%. The pressure signal from the high pressure damper is filtered and amplified. The outlet of this stage is the input voltage (UIn) for the A/D converter. The same signal is directly fed to the BNC output which has a resolution of 2 mV/bar for the range between 0 to 440 bar. The output has an offset of 30 mV (typical value) for offset compensation of the damping unit. The comparator compares reference signal and actual pressure signal. In case of overpressure conditions the flow will be reduced via the PDC board. The A/D converter allows different operation modes. Measurements of the difference between URef - UIn in relation to the reference (Ref) value or the absolute measurement of UIn - AGND in relation to Ref is possible. The results will be used by the processor to show the pressure ripple and the actual pressure on the display. It is also used to reduce the flow in case of overpressure conditions and for the online diagnostic (for example gas bubble detector, ball valve check, and so on). The BNC output is an additional diagnostic tool for checking the performance of the pump. For normal operation the use of the displayed pressure ripple is sufficient. Service Handbook for 1050 Series of HPLC Modules - 11/2001 125 Pumps: Electronic Information Relative A/D Converter Board (RAD) Figure 34 Board Layout RAD 126 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information Firmware Board (SFW) Firmware Board (SFW) Repair Level: Board Table 39 Part Numbers for FIM Board Item Part Number Firmware Board (SWF) 01018-66506 The SFW board is a piggy back board, placed on RAD board (’personality module’). • The programmed SFW contains the firmware of the 1050 pump module. • The board is designed for on board programming. • The FIM contains 128K x 8bit EPROMs. • All inputs/outputs are pulled down for electrostatic discharge protection. Figure 35 Layout of SFW Board Service Handbook for 1050 Series of HPLC Modules - 11/2001 127 Pumps: Electronic Information HRI Board - Heater Isocratic Board HRI Board - Heater Isocratic Board Repair Level: Board or Fuses Table 40 Part Numbers for HRI Board Item Part Number HRI 01018-66517 Fuse: F4, 2.5 A 2110-0083 The main function of the board is to control the column heater in the solvent conditioning module of the 1050 Isocratic Pump. Fuse Fuse F4 (2.5A) protects the +24V for the heater foil for overcurrent conditions. Control Logic The control logic synchronizes the communication between the HRI and the main processor. Status Register The register provides the main processor with the board identification. Synchronization The circuit receives the timing for the D/A converter from the main processor via the control logic. Synchronization adapts the timing to the needs of the 12 bit D/A converter. Pulse Width Modulator When the column heater is turned on the main processor provides control signals to the pulse width modulator. The output is a TTL signal with a duty cycle which depends on the temperature difference (error signal) between actual and setpoint temperature. 128 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information HRI Board - Heater Isocratic Board Figure 36 Block Diagram HRI/HRQ Board Service Handbook for 1050 Series of HPLC Modules - 11/2001 129 Pumps: Electronic Information HRI Board - Heater Isocratic Board Temperature Measurement The temperature of the heat exchanger is measured with a Pt. 100 temperature sensor. (Resistance 1000 Ohm; at 0°C and approximately 1400 Ohm; at 100°C). The temperature converter circuit provides an analog signal (0V to +5V) correlating to the temperature of the heating block. The chosen setpoint temperature is converted in a reference voltage via the 12 bit A/D converter. Actual and setpoint temperature are then compared in the comparator. The derived error signal is send via Latch 1 to the main processor which updates the necessary signals for the heating section. The sensor check circuit provides information whether the temperature sensor is installed or not. Heater Driver The heater driver circuit contains the power stages for the heater foil. If the temperature of the heater block exceeds 100°C a over-temperature switch on the heater foil interrupts the connection to the heater driver. Latch 2 The latch provides the signals to the multi color LED which gives visible information about the heater status. The LED shines green when the heater is on and at correct temperature. When maintaining the temperature the LED flashes yellow indicating the percentage of power used. The LED shines yellow when the heater is on and is at correct temperature but the not ready time has not been elapsed. During the heating up phase the LED flashes yellow. A red LED appears in case of error conditions. The system ok signal (SOK) of the processor is connected to the latch. In case of problems Latch 1 and the PWM are disabled and the heating process is interrupted. Board Layout Refer to “Board Layout HRI/HRQ” on page 133. 130 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information Heater Quaternary Board (HRQ) Heater Quaternary Board (HRQ) Repair Level: Exchange Board or Fuses Table 41 Part Numbers for HRQ Board Item Part Number Exchange HRQ 01018-66518 01018-69518 Fuse: F4, 2.5 A 2110-0083 Fuse: F16, 1 A 2110-0007 The main function of the board is the control of the column heater as well as the multi channel gradient valve (MCGV). The board comprises the function of the HRI Board. Therefore only the multi channel gradient control has been described. The HRQ board replaced the gradient valve driver board (GVD) which controlled the MCGV. Block Diagram Refer to “Block Diagram HRI/HRQ Board” on page 129. Fuses Fuse F16 (1A) protects the +36V for the multi channel gradient valve (MCGV) for overcurrent conditions. Originally the fuse had 500 mA which was a incorrect value. Control Logic The control logic synchronizes the communication between the HRQ and the main processor. Valve Sequence Register The valve sequence register contains the information about the sequence in which the solenoids of the MCGV should be activated (for example A, B, C, D or A, C, D and so on). Service Handbook for 1050 Series of HPLC Modules - 11/2001 131 Pumps: Electronic Information Heater Quaternary Board (HRQ) 4 Bit Counter The control chip divides the piston path length for one stroke into four parts. The length for each part is depending on the flow composition. The four bit counter gets a pulse each time the portion is changed. The output is a 2 bit data word for the valve select memory. Valve Select Memory The following figure shows an example for the input and output of the valve select memory circuit. The channel number information comes from the 4 bit counter. The pump drive control board (PDC) supplies the gradient power pulse (GPP) and the blank out pulse (BOP). GPP delivers the power switching signals for the multi channel gradient valve (MCGV). BOP makes sure that all solenoids of the MCGV are switched off before opening the next one. Valve sequence register gives the relation between the four piston portions and the solvent channels. Output of the valve select memory is the accurate timing for the four solenoids of the MCGV. Figure 37 Valve Select Memory Signals Valve Driver The valve Driver contains the power stages for the multi channel gradient valve (MCGV). 132 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information Heater Quaternary Board (HRQ) Common Valve Switch Fast switching of the four valves without any interference between the channels is achieved with the common valve switch. One side of all the four valves is connected together and is opened each time before switching to the next valve (BOP). Figure 38 Board Layout HRI/HRQ Service Handbook for 1050 Series of HPLC Modules - 11/2001 133 Pumps: Electronic Information High Pressure Transducer Board (HPT) High Pressure Transducer Board (HPT) Repair Level: Damper The High Pressure Transducer Board (HPT) is built into the High Pressure Damper and measures the system pressure on the high pressure side. A negative going voltage is provided showing a linear characteristic between 0 bar to 440 bar from -1 V to -8 V. The measurement is taken with a strain gauge bridge. The firmware of the pump allows a interactive offset adjustment for the damping unit. In certain limits the software compensates the offset of the high pressure transducer. N OT E The HPT is installed and preadjusted in the factory. In case of malfunctions the complete assembly should be replaced in the field. Figure 39 HPT Pressure Diagram 134 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information High Pressure Transducer Board (HPT) Figure 40 Block Diagram HPT Service Handbook for 1050 Series of HPLC Modules - 11/2001 135 Pumps: Electronic Information Connector Board (CON) Connector Board (CON) Repair Level: Board or Fuse Table 42 Part Numbers for CON Board Item Part Number CON (NEW) 01018-66505 Fuse: F2, 375 mA 2110-0421 The connector board (CON) allows easy access to plugs for the multi channel gradient valve (MCGV) active inlet valve and the leak sensor. The connector cable transmits the signals to the motherboard and from there it is fed to the various boards. The fuse protects the active inlet valve circuit for overcurrent conditions (only on board revisions B and greater). Figure 41 Board Layout CON 136 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information Connector Board (CON) Table 43 CON Connectors Connector Function J1 MCGV J2 not used J3 Active Inlet Valve J4 Leak Sensor J5 Cable J1 MCGV Service Handbook for 1050 Series of HPLC Modules - 11/2001 137 Pumps: Electronic Information Pump Motherboard (HPS) Pump Motherboard (HPS) Repair Level: Board Table 44 Part Numbers for LUM Board Item Part Number HPS Board 01018-66501 The Motherboard connects the various boards of the pump to each other and supplies the signals for the front parts like metering drive, damper, MCGV, fan and keyboard. Figure 42 shows the location of all connectors, Figure 43 to Figure 45 show the main signals of the pump. Figure 42 Layout of Pump Motherboard J1 - Power Supply J6 - Not used J11 - Fan J2 - PDC Board J7 - CMP J12 - High Pressure Damper J3 - RAD/SFW Board J8 - FIP Keyboard J13 - Connector Board Cable J4 - not used yet J9 - Temperature Sensor J14 - Metering Drive Motor J5 - HRI/HRQ Board J10 J15 - Shaft Encoder 138 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information Pump Motherboard (HPS) Figure 43 Connection Table HPS (I) Service Handbook for 1050 Series of HPLC Modules - 11/2001 139 Pumps: Electronic Information Pump Motherboard (HPS) Figure 44 Connection Table LUM (II) 140 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Electronic Information Pump Motherboard (HPS) Figure 45 Connection Table LUM (III) Service Handbook for 1050 Series of HPLC Modules - 11/2001 141 Pumps: Electronic Information Pump Motherboard (HPS) 142 Service Handbook for 1050 Series of HPLC Modules - 11/2001 7 7 Pumps: Diagnostic Information This chapter provides information on error messages and diagnostic features of the 1050 Pumps Pumps: Diagnostic Information This chapter provides information about: • Test Functions • Flow (Pressure) Tests • Pump Pressure Ripple • Normal Pressure Test • Modified Pressure Test • Flow Test Method - Firmware Revision 1.0 • Flow Test Method - Firmware Revision 3.0 and above • Gradient Test • Error Messages • Selftest • Common 1050 Messages • Pump Initialization • Normal Operation • Column Heater • Online Monitor • Troubleshooting Hints (Pressure Tests) • Pressure Tests with water and methanol • Pressure Tests when the pump is broken 144 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information How to use the Diagnostic Test Functions How to use the Diagnostic Test Functions The test function of the firmware is part of the control section. The first test function is a online monitor of the actual pressure ripple. The two other programs allow verification of the pump performance. The two test methods are also used for the final test of the 1050 Pump modules. Press CTRL and with Next move the cursor to TEST FUNCTIONS (enter) After pressing Enter the following TEST FUNCTIONS are accessible. PUMP PRESSURE RIPPLE YY.Y% Monitors the actual flow ripple if the diagnosis level (Configuration) is turned on (1, 2 or 3). LOAD FLOW TEST METHOD Loads a special program (pressure test) for performance verification of the flow system. LOAD GRADIENT TEST METHOD Loads a gradient test program (tracer test) for the performance of the gradient system. Service Handbook for 1050 Series of HPLC Modules - 11/2001 145 Pumps: Diagnostic Information Pump Pressure Ripple Pump Pressure Ripple The pressure ripple display shows the actual pressure variation of the solvent flow. It can be used as a quick check for determination of gas bubbles in the system. If the online diagnostic is turned on no pressure ripple (--.-%) indicates either no flow in the system or too many gas bubbles in the system exceeding the measurement range or a pressure below 30 bar to 50 bar. Positive pressure ripple values (for example 0.5%) are shown when the pump is overcompensated. Negative pressure ripple values (for example -0.8%) are shown in case of an under compensated pump. Whether the values in the display are either positive or negative is strictly depending on the solvents in use and the respective pressure compensation values which are user selectable. Typical pressure ripple readings are in the range ±1%. A higher ripple which can not be reduced by pressure compensation changes may indicate an air bubble. N OT E In purge mode the pressure ripple is not measured. The display might show incorrect values during this time. 146 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Flow (Pressure) Tests Flow (Pressure) Tests The pump has an analog output for the pressure signal for monitoring and troubleshooting purposes. The tightness and performance of the pump can be tested with various pressure tests. The outlet of the pump will be blocked and depending on the chosen pressure test the system pressure rises until it is stopped either by the program itself or the pressure limit. The plotted pressure signal provides information about the performance of the system. In case of system failures it might be possible to combine the pressure tests for clear identification of the failing part. Firmware revision 3.0 and above These firmware provide an additional feature which allows to monitor which of the two piston is delivering into the system. This is a very helpful tool when troubleshooting the system. Pressure drops in the pressure tests can be related to the delivering piston. Conclusions which parts failed are much easier done. Press Status and twice Next to get the following display. currently active piston 1 The display shows whether piston 1 or piston 2 are just delivering into the system. ** indicates that the change from one piston to the other is to fast to be monitored (flow >1.2 ml/min). Service Handbook for 1050 Series of HPLC Modules - 11/2001 147 Pumps: Diagnostic Information Flow (Pressure) Tests Prerequisites for the Pressure Tests 1 Place a bottle of isopropanol (HPLC grade) into the solvent cabinet and connect it to one of the solvent channels (lets take channel B). 2 Switch on the degassing for that channel and establish an appropriate helium flow rate in the bottle. 3 Connect the signal cable between RAD board and integrator input (for example a 339X integrator). The pressure signal provides 2 mV/bar. 4 Purge the channel (B). Observe the pressure reading until the value is stable. The pump pressure ripple display should show a value in the range ±0.5% for isopropanol (with default settings). N OT E If the system is not well primed or degassed incorrect measurements may be taken resulting in wrong interpretation of the plots. 5 Set Integrator parameters (339X series). Zero 10 ATT 210 CHART SPEED 2 cm/min 148 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Flow (Pressure) Tests Normal Pressure Test This test is well known for verifying system tightness. ❏ Turn on pump and set FLOW 0.000 ml/min and disconnect the interface tubing at pump outlet. ❏ Plug pump outlet with a blank nut (01080-83202). ❏ Start the integrator with the plot mode. ❏ Set Flow FLOW 1.000 ml/min to start the pressure test. Figure 46 Normal Pressure Plot with IPA Explanations to Plot The plot shows a typical pressure profile of a normal performing 1050 Pump. With the flow of 1 ml/min the pressure in the system raises until the pump stops via the overpressure condition at 400 bar. After one minute wait time the pressure drop should not exceed 5 bar/min. Service Handbook for 1050 Series of HPLC Modules - 11/2001 149 Pumps: Diagnostic Information Flow (Pressure) Tests The Modified Pressure Test This test is a slight modification of the previous used normal pressure test. ❏ Turn pump on, set FLOW 0.000ml/min and disconnect the interface capillary at the outlet of the pump. ❏ Plug pump outlet with a blank nut (01080-83202). ❏ Start the integrator with the plot mode. ❏ Set Flow FLOW 1.000ml/min to start the pressure test. ❏ Observe the pressure display and reduce the flow to FLOW 0.100ml/min at approximately 200 bar. Figure 47 Modified Pressure Test with IPA Explanations to the Modified Pressure Plot The plot shows a typical pressure profile of a normal performing 1050 Pump. The pressure in the system rises as seen in the previous test. When switched to the reduced flow rate the pressure increases with a lower slope. During the time until the system pressure limit will be reached piston I and II deliver alternately into the system. A straight line as seen indicates that both piston chambers are leak free. After switched off at 400 bar and one minute wait time the pressure drop should not exceed 5 bar/min. 150 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Flow (Pressure) Tests Flow Test Method The firmware of the pump module holds a firmware resident flow test method which contains the parameters for the pressure test. The parameters cannot be displayed. During the life time of the instrument the firmware has been changed (communication update rev. 1.0 to 3.0) and the flow test method was revised. Therefore firmware revision 1.0 and 3.0 run different tests when the flow test method will be executed. ❏ Place a bottle of isopropanol (HPLC grade) into the solvent cabinet and connect it to one of the solvent channels (lets assume its channel B). ❏ Set PRIMARY CHANNEL B N OT E The Test Method uses exclusively the solvent specified by the primary channel and ignores the setting of the % display. However for flushing the system a setting %B 100 is necessary. ❏ Connect the signal cable between RAD board and integrator input. ❏ Flush the system. Observe the pressure reading until the value is stable. (hint: use pressure ripple display). ❏ Set FLOW 0.000ml/min and disconnect interface tubing at pump outlet. ❏ Load Flow Test Method. N OT E Loading the flow test method resets the pump an action which moves the pistons into a predefined position. In addition the instrument sets the actual flow to zero (FLOW 0.000ml/min) if not already set. ❏ Plug the pump outlet with a blank nut (01080-83202). ❏ Set integrator parameters (339XA) Attenuation 210 Chart Speed 1 cm/min (PLOT mode). ❏ Press START, then ENTER to run the test method. Service Handbook for 1050 Series of HPLC Modules - 11/2001 151 Pumps: Diagnostic Information Flow (Pressure) Tests Flow Test Method - Firmware Rev. 1.0 Figure 48 Pressure Test (Rev. 1.0) with IPA Explanations to Pressure Plot The plot shows a typical pressure profile of a normal performing 1050 Pump. Following are some remarks to the various steps in the plot. N OT E The pump displaces approximately 150 µl until the first plateau will be reached at a pressure of 120 to 130 bar. After pump initialization the 1. piston is in its upper position which means the 2. piston starts delivering into the system. With the given stroke length of 70 µl strokes of both pistons (II-I-II- I)| are necessary to reach the 1. plateau. Drastic leaks at active inlet valve outlet ball valve or seals will disturb the intake stroke of the 1. piston. The result might be a pressure drop when the 1. piston takes over to deliver into the system at a pressure between 20 to 40 bar. If the pressure test does not reach the first plateau the pressure plot cannot give any reliable diagnostic or troubleshooting hints. 152 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Flow (Pressure) Tests 1 From the predefined position the pistons start moving with a flow of 150 µ| and rises the pressure in the pump. 2 At the first plateau the firmware makes sure that the first piston is delivering into the pump. With the very small flow rate of 2 µl the pump pressure should remain stable. During the 1min at this plateau a maximum pressure drop of 5 bar is allowed (pressure display). At this position the tightness of the whole system is measured. 3 Pressure is increased until the second piston is delivering. 4 At the second plateau the second piston is delivering into the system with a flow of 2 µl. Again a straight line is expected. A pressure drop of 5 bar during the 1min is allowed. 5 The pistons move now with a higher speed (flow 500 µl/min) increasing the pressure in the system. 6 While increasing system pressure the pistons move with a stroke volume of 4 µl. The system pressure must reach a value of 330 bar ±30 bar. This part of the test checks for the mechanical tolerances from system to system and is of minor interest for system troubleshooting. 7 The system pressure is increased until the system shows an overpressure condition (>400 bar) which turns the pump off. 1 min after turning off the pump pressure drop should not exceed 5 bar/min. Possible Failure Modes The most relevant service information are obtained from the plot of the first (2) and second (4) plateau of the pressure plot. Three major failure modes are possible. For troubleshooting the system both plateaus should be seen together and not separately. The following plots show the different failure modes. Service Handbook for 1050 Series of HPLC Modules - 11/2001 153 Pumps: Diagnostic Information Flow (Pressure) Tests Straight line at first plateau but negative slope at second plateau Figure 49 Negative Slope at second Plateau The plot shows a leak free system when the first piston provides the flow. But during the stroke of the second piston the pressure drops down indicating a internal leak. The pump seals are definitely ok. Possible failure: Contaminated outlet ball valve (backflow). 154 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Flow (Pressure) Tests Negative slope at first plateau and stable plot at second plateau Figure 50 First Plateau unstable Plot shows malfunction in the system when the first piston maintains the pressure in the system. The delivery stroke of the second piston is separated from the first one via the outlet ball valve and shows no problem. Possible failure: • leak at first piston seal • leak at active inlet valve • no tight connection at outlet ball valve. Service Handbook for 1050 Series of HPLC Modules - 11/2001 155 Pumps: Diagnostic Information Flow (Pressure) Tests Negative slope at both pistons Figure 51 Problems at both Plateaus Plot shows same failure mode on both pistons when maintaining the pressure in the pump. Under the assumption that the slope has the same angle for both “plateaus” it can be said that the problem is probably coming from the second piston chamber. Different angles indicate more than one leak in the pump. Possible failure • Blank nut not tight enough • Fittings at frit adapter assembly or damper not tight • Leaking piston seal at second piston. 156 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Flow (Pressure) Tests Flow Test Method - Firmware Rev. 3.0 and above Figure 52 Pressure Test (Rev. 3.0) with IPA Explanations to Pressure Plot N OT E This flow test method is pressure controlled. The actual pressure has to exceed at least 270 bar for the first step otherwise the test cannot reach the following steps. 1 Starting with a flow of 500 µl/min and a stroke of 20 µl the pump starts delivering into the system. The pressure rises until the damper detects a system pressure of more than 270 bar. The pump continues to deliver with the same parameters until piston I reaches its upper limit. At this position the stroke is changed to 80 µl and piston II delivers one stroke with the larger stroke volume. 2 Now the flow is changed to 100 µl/min (stroke 80 µl) and piston I continues with this parameters for about 1/3 of its stroke. 3 At the plateau piston I delivers for approximately 1 minute with a very low flow rate (4 µl) into the system. A straight line or a slight pressure increase is expected for a normal performing pump. A pressure drop during this minute indicates a problem in the pump. Service Handbook for 1050 Series of HPLC Modules - 11/2001 157 Pumps: Diagnostic Information Flow (Pressure) Tests 4 Piston II delivers into the system. At the end of the first plateau the flow is increased back to 500 µl until piston II reaches approximately 1/3 of its stroke. At the second plateau piston II delivers with a very low flow rate (4 µl) into the system. A straight line or a slight pressure increase is expected for a normal performing pump. A pressure drop during this minute indicates a problem in the pump. 5 The flow is increased to 250 µl and the pumps works with this rate until the damper detects more than 390 bar. The flow is set to zero and the test is finished. It might happen that the system stops with a pressure slightly below 400 bar. This allows to restart the pump without reset. In most of the cases the pressure will exceed the upper pressure limit of 400 bar and will show the error message. 1 minute after reaching the maximum pressure of the test the pressure drop should not exceed 5 bar/min. Possible Failure Modes The plateaus (3, 4) of the pressure test provide the same information like in the previous test (Rev. 1.0). The only difference is that the two plateaus are moved to higher pressure values. The section pressure plots of this manual will provide additional pressure tests under failure conditions of the pump. 158 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Gradient Test Method Gradient Test Method The test measures all the relevant data which have an influence on the pump performance. The step performance of the MCGV and the gradient linearity are controlled with this tracer test. The tracer test is a chromatographic test and therefore requires a UV detector connected (no column installed) to the 1050 Pump module. The gradient test is decided into two parts. The first part tests the step reproducibility of a gradient and the second part tests the linearity of a gradient. Prerequisites for the Gradient Test Method Place the following solvents (HPLC grade) into the solvent cabinet and degas them thoroughly. Channel A Distilled Water Channel B Tracer (Isopropanol + 0.5% Acetone) Channel C Isopropanol Channel D Isopropanol Running the Gradient Test Method 1 Flush each channel for a couple of minutes. 2 Connect the outlet capillary of the pump to a detector. 3 Set detector parameters Sample Wavelength 267 nm (Bandwidth 4 nm) or equivalent, Reference Wavelength 550 nm, 100 (if available) or equivalent or fixed reference. 4 Connect the signal cable between detector and integrator. Service Handbook for 1050 Series of HPLC Modules - 11/2001 159 Pumps: Diagnostic Information Gradient Test Method 5 Set integrator parameters (339X). Zero = 5 Att 2^ = ** CHT SP = 1.0 PK WD = 0.01 THRSH = 11 AT 12 min Att 2^ = ** AT 12 min CHT SP = 0.5 AT 45 min STOP ** The tracer concentration may vary from mixture to mixture. Therefore check for the appropriate integrator attenuation. Start the integrator manually change %B = 7 observe the plot and adjust the attenuation to a value which gives the highest deflection without exceeding the paper range. Proceed in the same way with %B = 100. Set the pump parameters back to start values (%B = 0). 6 Load gradient test method. 7 Press START, then ENTER to run the test method. Figure 53 Gradient Test Method (part 1) 160 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Gradient Test Method Figure 54 Gradient Test Method (part 2) Explanations to Gradient Test In the first part of the test the step reproducibility will be tested. The steps should have all the same height except the last two steps. The last steps (from 2% to 1% to 0%) will not have the same step height because of a too small solvent volume versus the switching time at this positions. In addition the composition precision can be tested. The noise on each of the steps should not exceed 50% of the step height. Typically values of 30% representing a composition precision of ±0.15% are reached. In the second part of the test the gradient linearity will be verified. Except of the bump at the upper end of the gradient the curve should show a straight line indicating a good linearity of the system. Be aware that the performance of the detector (linearity, stray light, and so on) will have a significant impact on the results. Service Handbook for 1050 Series of HPLC Modules - 11/2001 161 Pumps: Diagnostic Information Error Messages Error Messages The error messages will help to locate and repair a failure. In case an error message appears the Error LED will be turned on and the message will be written into the system logbook. Reset Pump or switching on the pump again will reset the error. The entry in the logbook remains. The error messages can be divided into the following blocks: • Selftest • PANIC Error • Common 1050 Messages • Pump Initialization • Normal Operation • Column Heater • Online Monitor 162 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Selftest Selftest ROM/RAM Test RAM and display can be tested via the build in selftest. The selftest will be performed when CRTL will be pressed while the module is turned on at the LINE~ switch. In case of a failure one of the following messages appears. The complete test requires approximately two minutes. ROM test failed ( ROM test failed ) The ROMs on the SFW board are tested. In case of a checksum error the ROM test fails. ❏ Replace the SFW board. RAM test failed ( RAM test failed ) The RAM’s on the CMP board will be tested. In case of a failure the error message appears and the CMP has to be replaced. ❏ Replace the CMP board. Service Handbook for 1050 Series of HPLC Modules - 11/2001 163 Pumps: Diagnostic Information Panic Error / Bus Error Address Error Panic Error / Bus Error Address Error PANIC: XXXXXXH BUS ERROR PANIC: XXXXXXH Address ERROR The panic error messages should not appear under normal operation conditions. In case of hardware or firmware problems the instrument might try to access a wrong or not existing address which results in the error message on the display. The instrument is locked up and has to be switched off/on. Reason for the PANIC error message can be any disturbance on the bus lines due to bad contacts (high resistance) or defective IC on any of the boards. ❏ Check boards for good connections or corrosions at the contacts (clean contact pins). ❏ Check revision of firmware board (SWF). It should be revision C or higher. Revision C boards do have a dynamic bus termination for spike suppression on the bus lines. ❏ Replace one board at a time to identify the faulty one. ❏ If board replacement will not cure the problem replace the motherboard. 164 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Common 1050 Error Messages Common 1050 Error Messages The common messages are either event or error messages which may appear in all the 1050 series modules. The messages are identical or very similar in the various modules. E00 : Power Fail E00 HH:MM DDMMM power fail > This message indicates that the instrument has either been disconnected from line source or a line power voltage drop has occurred. System clock will stop and has to be set again after turning on the pump. E01 : Leak Detected E01 HH:MM DDMMM leak detected > leak detected in pump The leak detection system uses a PTC resistor as leak sensing item. Liquid cooling the PTC results in a decrease of the resistance. The PTC is built in a resistor divider which is connected to a constant voltage. From the voltage divider a signal can now be obtained depending on the current through the PTC and hence depending on the temperature. The leak detection circuit is located on the CMP board and checks continuously for presence and leak conditions. If the sensor is missing (defect) or in leak condition the PTC is cooled down the error message appears (only when pump motor was turned on beforehand otherwise only a status information is given). When the module is turned on the leak message will be disabled for a short period of time (30 seconds) to allow the sensor to warm up and stabilize. Working condition of the PTC Normal: about 75°C 400...500 Ohm Error: below 55°C about 150 Ohm Service Handbook for 1050 Series of HPLC Modules - 11/2001 165 Pumps: Diagnostic Information Common 1050 Error Messages Actions: ❏ Check for leaks in the pump module. ❏ Check connector of the sensor. ❏ Check resistance of leak sensor. ❏ Change leak sensor. ❏ Change CMP board. ❏ Change SFW board. E02 : Shutdown In Other Module E02 HH:MM DDMMM shut down > error in other module An external device pulled the shut down line of the remote connector down. This forces the pump to stop the pump motor inhibiting a flow into the system. Probably a leak appeared in one of the connected modules. E03 : Error Method loaded E03 HH:MM DDMMM error method > error method has been loaded The operator may define a method as a error method. The event message indicates that the module detected an error and that the error method was loaded. E04 : Time Out E04 HH:MM DDMMM time out The operator may define a time after which the instruments stops all further actions. Mainly two cases will lead to the time out message. First if a normal run is finished the pump is turned off after the specified time (only if no new start command appears during this time). Second a not ready condition in a sequence mode or in multiple run mode will start the time out timer eventually leading to the message. 166 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Pump Initialization Error Messages Pump Initialization Error Messages During the pump initialization the system performs some start up routines to prepare the motor drive system for normal operation. The system starts the servo system and measures the upper dead center of the first piston. Malfunctions during the turn on process will lead to the following error messages. E11 : Gradient feedback failed E11 HH:MM DDMMM init failed > gradient feedback failed In case the gradient valve (MCGV) is installed and recognized during boot up the system turns on the Primary Channel before it starts with any other action. The error message indicates that the primary channel could not be turned on. Reason is an communication problem between the pump drive control board (PDC) and gradient valve driver board (HRQ). ❏ Check for proper connection of HRQ and PDC boards. ❏ Replace HRQ board. ❏ Replace PDC board. Work around: Set different primary channels one of them should work. Use pre mixed solvents and connect the solvent directly to the active inlet valve. E12 : Servo restart failed E12 HH:MM DDMMM init failed > servo restart failed > The first action for the servo motor is to switch on the C-phase of the variable reluctance motor. The rotor will move to one of the C-positions. This action is called the Servo Restart. From such a rotor stator relation the servo will be able to take over the phase sequencing with the commutator (on the PDC board). If the rotor is not able to move or the C-phase cannot be reached the error message appears. ❏ Check Fuse on the PDC board. ❏ Check cables to pump motor. ❏ Check for mechanical blockage of the drive system. ❏ Change PDC board. ❏ Change drive assembly. Service Handbook for 1050 Series of HPLC Modules - 11/2001 167 Pumps: Diagnostic Information Pump Initialization Error Messages E13 : Pump timeout E13 HH:MM DDMMM init failed > pump timeout After restart the pump will move the first piston to its upper position. The upper position is recognized when the piston touches the mechanical stop rising drive power for the blocked motor. If the piston will not reach the upper limit within one minute the initialization will be stopped and the error message appears. ❏ Check gears of the drive assembly (broken coupler?). ❏ Change PDC board. ❏ Change the drive assembly. E14 / E15 / E16 The following three error messages use the same measurement principle with different limits. During the pump initialization the first piston hits the upper dead center of the pump head and stops there. To make sure that the piston will not run into this mechanical stop during normal operation the index hole of the motor shaft encoder wheel is used as the initialization reference. From the upper center the piston travels back until it reaches the index hole. There will be no reinitialization during normal operation (initialization only during pump on procedure or pump reset command). The Index position is expected in a certain range from the upper dead center. If the Index does not appear in this range one of the three messages will show up on the display. E14 : Home position not found E14 HH:MM DDMMM init failed > home position not found After the piston has hit the upper limit it will move down to find the first Index hole of the encoder. If the Index is not found in the maximum allowed number of steps this error message appears. The communication to the shaft encoder index hole is missing. ❏ Check cable and connector of the encoder. ❏ Check PDC board connection. ❏ Change PDC board. ❏ Change Drive Assembly. 168 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Pump Initialization Error Messages E15 : Home position out of limit E15 HH:MM DDMMM init failed > home position out of limit When the motor is stopped for reversing the direction the moment of inertia of motor and spindle will continue the movement for certain steps until it finally stops. Therefore an minimum number of steps is necessary until the Index should be reached. In case the number is to small this error message appears. Changed adjustment or sticking movement of the system can be the reason for this. ❏ Check drive system for smooth movement. ❏ Change motor drive assembly. ❏ Change PDC board. E16 : Pump head missing E16 HH:MM DDMMM init failed > pump head missing The mechanical tolerances from one system to the other need an offset compensation to make sure that the piston reverses its direction always at the same position. If the distance between the upper limit and the first index exceeds the compensation range but is still below the maximum limit (E14) the error message will show up. Reason can be that the pump head is missing or not mounted in the right way. ❏ Mount pump head correctly. ❏ Check drive system for smooth movement. ❏ Change motor drive assembly. ❏ Change PDC board. E17 : Idle power exceeded E17 HH:MM DDMMM init failed > idle power exceeded The PDC board measures the actual electrical current. If the motor needs more then a defined current for a pressure free pump it indicate a failure in the system. Reason is either an tight mechanical system or a defective motor. ❏ Check drive system for smooth movement. ❏ Check PDC board. Service Handbook for 1050 Series of HPLC Modules - 11/2001 169 Pumps: Diagnostic Information Pump Initialization Error Messages E18 : Stroke length misadjusted E18 HH:MM DDMMM init failed > stroke length misadjusted This error message appears only when the pump is running in DIAGNOSE LEVEL 3 which is a manufacturing test. The error indicates a incorrect spindle position adjustment. Hint: If error message E27 occurs when pump works with 100 µl stroke volume diagnose level 3 allows a quick check of the pump. Set diagnose level 3 and turn on pump. If E18 occurs the metering drive is mis-adjusted and generates the E27 problem. Metering drive has to be changed. 170 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Normal Operation Error Messages Normal Operation Error Messages Operation error messages can be detected at any time of a normal operation. They are normally independent of the current state of the pump. The ERROR LED will be ON and the message will be entered in the logbook. Restarting the pump will reset the error. E19 : Pressure above upper limit E19 HH:MM DDMMM press too high > pressure above upper limit The actual pressure in the system is continuously monitored during operation of the pump. The firmware allows only operation up to the user defined upper limit, if not in purge mode. If the high pressure damper detects more than the upper limit the pump is turned off or a specified error method will be activated and the error message appears. All this measurements are performed on the RAD board. ❏ Check flow system for blockages. ❏ Check Flow setting. ❏ Change RAD board. E20 : Pressure above maximum limit E20 HH:MM DDMMM press too high > pressure above maximum limit The system pressure is normally checked with the upper and lower limit values. In case of any malfunction (for example pump does not stop at 400 bar rapid fast pressure increase) in the system which allow the pressure to rise above 420 bar the pump is stopped and the error message appears. This message shows up when the system is blocked and the pressure shoots up very fast (pressure test). ❏ Check flow system for blockages. ❏ Check flow setting. ❏ Change RAD board. ❏ Change PDC board. Service Handbook for 1050 Series of HPLC Modules - 11/2001 171 Pumps: Diagnostic Information Normal Operation Error Messages E21 : Pressure below lower limit E21 HH:MM DDMMM press too low > pressure below lower limit The lower limit value function is firmware controlled. In case the system pressure drops once below a user defined value the pump motor will be turned off or the specified error method will be activated and the error message appears. The error message allows to check the system for empty solvent bottles, broken capillaries, fitting leakage and so on. ❏ Check flow value and solvent composition. ❏ Check all seals and fittings in the complete LC system. E22 : Temperature sensor failed E22 HH:MM DDMMM sensor failed > temperature sensor failed While the pump is turned on the firmware checks for the presence of the temperature sensor. In case the sensor is disconnected defective or the sensor is activated (switch open) by an over temperature condition the error message appears. The temperature sensor switch opens at 90°C and the pump motor will be turned off. ❏ Check fan. ❏ Check air filters. ❏ Check sensor with meter. ❏ Change metering drive. ❏ Change RAD board. E23 : Motor temperature exceeded limit E23 HH:MM DDMMM overtemperature> motor temp exceeded limit The highest power consumption in the module is inside the variable reluctance motor. High system back pressure at low flow rates results in maximum heat dissipation. A fan and a special designed foam part make sure that the heat of the motor is brought out of the instrument. In case the airstream of the module is interrupted or the fan fails the motor temperature will rise above allowed limits. A thermal switch is mounted on the surface of the motor and turns off the pump when the temperature exceeds 90°C. The error event circuit reacts immediately on the PDC board and turns off the pump motor power. The same signal line on the PDC board is also used from the system ok command (SOK). This means that the error also appears in case of a SOK error. The SOK is set when the processor has locked up 172 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Normal Operation Error Messages preventing damage of pump or others or one of the boards holds the signal down. ❏ Check fan. ❏ Check air flow path. ❏ Check temperature of the motor. ❏ Change PDC board. ❏ Check all other boards in the system. ❏ Change CMP board. E24 : Inlet valve disconnected E24 HH:MM DDMMM valve missing > inlet valve disconnected If the active inlet valve is disconnected and the first piston is delivering solvent the valve may be damaged. Therefore the presence of the active inlet valve is controlled. In case the active inlet valve is not connected during the initialization of the pump the pump motor is turned off and the message occurs. ❏ Check Connector of the valve. ❏ Check the connector cable to the motherboard. ❏ Change RAD board. E25 : Adjust pressure offset E25 HH:MM DDMMM pressure offset> adjust pressure offset The high pressure damping unit measures the system pressure in the range from 0 to 400 bar. Thermal drift of the electronic components may cause drift to negative values. If the pressure offset is below -15 bar the error message appears on the display. Incorrect adjustment may influence the pump performance (pressure ripple measurement and so on). ❏ Perform offset adjustment. ❏ Check connector of damping unit. ❏ Change RAD board. ❏ Change damping unit. Service Handbook for 1050 Series of HPLC Modules - 11/2001 173 Pumps: Diagnostic Information Normal Operation Error Messages E26 : Pump drive lost init values E26 HH:MM DDMMM init lost pump drive lost init values The reference position for the upper limit of the piston is reached during each pump cycle. In case the difference of the actual value in relation to the value of the initialization is too large the system will turn off the pump and the error message appears. ❏ Check connector and cable of the encoder. ❏ Change PDC board. ❏ Change motor drive assembly. E27 : Max motor drive E27 HH:MM DDMMM power use high> power exceeded max motor drive power exceeded The power consumption of the motor drive will be monitored. In case of servo failures or blockages of the ball screw drive the motor current will exceed the maximum limit and the processor will turn off the pump. ❏ Check motor drive for smooth movement. ❏ Check the +12 V on the PDC board. ❏ Change PDC board. ❏ Change motor drive assembly. ❏ Check outlet ball valve for blockages. E28 : Secondary Powerfail E28 HH:MM DDMMM Sec Powerfail > +12 V analog supply failed The +12 V generated on the PDC board will be continuously checked for under voltage conditions. In case the voltages drops below approximately +10 V the pump will shut down and the error message will appear. The +12 V will be also used on the RAD board and the pressure transducer board of the damping unit. ❏ Change the PDC Board. ❏ Change the RAD Board. ❏ Change the Damping Unit. 174 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Column Heater Error Messages Column Heater Error Messages The following messages may appear as you work with the column heater. E33 : Column heater cable disconnected E33 HH:MM DDMMM column heater > cable disconnected The firmware recognizes the column heater option when the cable is correct installed. If afterwards the cable is disconnected or a wrong cable is connected to the HRI/HRQ board the error message appears and the red error LED is turned on. N OT E When the remote cable is connected to the HRI/HRQ board the error message will appear and the +24 V of the board is disabled to prevent damage of the modules which are connected to the remote cable. If the column heater cable is connected to the remote connector of the pump module the LED on the heater module will lit yellow/red. ❏ Check for correct cabling of the column heater module. E34 : Column heater board failed E34 HH:MM DDMMM column heater > board failed The watch dog circuit on the CMP board (SOK signal) controls the correct communication between processor and interface boards. If the SOK signal is activated the error massage appears and the error LED of the pump module is turned on and the column heater LED shines red. Reason for the error can be either an electronic component failure or interference on the bus lines. ❏ Reboot the pump module. ❏ Reseat all boards in the card cage. ❏ Change the HRI/HRQ board. ❏ Change the CMP board. ❏ Change the CIB board. ❏ Change the SFW board. ❏ Change the HPS board. Service Handbook for 1050 Series of HPLC Modules - 11/2001 175 Pumps: Diagnostic Information Column Heater Error Messages E35 : Column heater overtemperature E35 HH:MM DDMMM column heater > overtemperature The column temperature is normally checked with the Pt. 100. In case of malfunctions the temperature may exceed the normal working range. At 90°C the firmware disables the heater circuit, sets the error message and turns on the red error LED at the pump and the column heater. In case the heater transistor is defective and still heats up the heat exchanger the over temperature switch on the heater foil opens at 100°C and interrupts heating. ❏ Change the HRI/HRQ board. E36 : Column heater fuse blown E36 HH:MM DDMMM column heater > fuse blown With the column heater turned on the firmware checks for the presence of the +24 V on the HRI/HRQ board. If fuse F4 is blown, the +24 V is missing and the instrument shows the error message, turns on the red error LED on the pump and the column heater module. The fuse blows in case of a shortage on the +24 V line. ❏ Replace fuse F4. 176 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Online Monitor Messages Online Monitor Messages The online monitor function checks the metering pump during normal operation and is described in the diagnostic section. Messages may appear when the chromatographic performance might be influenced or the instrument is in a special mode (initialization purge). The messages except of M01 and M11 are related to the Diagnose Level (0, 1, 2) of the instrument. If the diagnose level is turned off (0) the messages will be suppressed. Diagnose Level 1 writes the messages into the logbook with no further action. Diagnose Level 2 writes the messages into the logbook and the Not Ready LED will be turned ON. For more information about the online monitor, see the diagnostic chapter. M01 : Pump reference M01 HH:MM DDMMM initialized > initialized pumps reference initialized The initialization of the metering drive reference values appears under three conditions. First after initial turn on of the pump after boot up second with a reset pump command (Control Function) and third when the pump is turned on and the reference values have been lost for any reasons. In this case the message is an indication that a covered problem appeared while the pump was turned off. Because of its state (off) the pump could not show the malfunction and the instrument performs a new initialization. During this initialization the probable error will be cleared and when the error is not solid the pump will be turned on without problem. M02 / M03 : Gas bubble M02 HH:MM DDMMM gas bubble > gas problem ripple too high M03 HH:MM DDMMM bubble solved > problem solved ripple in range If the pressure ripple of the pump exceeds a certain range the message M02 appears. In case of a temporary disturbance the ripple might return to its normal working range and indicates this with message M03. ❏ Check for proper degassing. ❏ Check for appropriate compressibility setting. Service Handbook for 1050 Series of HPLC Modules - 11/2001 177 Pumps: Diagnostic Information Online Monitor Messages M04 / M05 : 1st piston M04 HH:MM DDMMM 1st piston leak> leak check seals or inlet valve M05 HH:MM DDMMM 1st piston ok > problem solved leak in range If the online monitor function detects a leak in the first piston chamber the above message M4 appears. If the instrument returns to normal operation (problem solved by user) the message M5 indicates a good working instrument. The occurrence of M4 is a very good indicator when the seals should be changed. ❏ Check for leaks a fittings. ❏ Check for tight connection of the active inlet valve. ❏ Change seals. ❏ Change active inlet valve. M06 / M07 : Valve backflow M06 HH:MM DDMMM valve backflow> check outlet valve M07 HH:MM DDMMM valve tight > problem solved no backflow M06 indicates that the pump detected a backflow in the outlet valve which indicates that the valve has been closed but is not tight. M07 indicates that the problem was solved. ❏ Clean outlet valve. ❏ Change outlet ball valve. M08 / M09 : Outlet Valve M08 HH:MM DDMMM outlet valve > clean outlet valve M09 HH:MM DDMMM outlet valve ok> problem solved outlet valve ok M08 appears when the outlet ball valve shows a time delay before it blocks the flow path in the correct way. This is an indication that the valve sticks and need to be cleaned. ❏ Clean outlet ball valve. ❏ Change outlet ball valve. 178 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Online Monitor Messages M11 : Purging mode activated M11 HH:MM DDMMM purging > purge mode activated This message shows when the instrument was purged the last time. Service Handbook for 1050 Series of HPLC Modules - 11/2001 179 Pumps: Diagnostic Information Troubleshooting Hints Troubleshooting Hints This section gives practical hints in troubleshooting the pumps according to the pressure plots: • Pressure Tests with different Solvents (water methanol) • Pressure Tests when the Pump is broken 180 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Standard Pressure Tests with different Solvents Standard Pressure Tests with different Solvents The factory tests all the 1050 Pumps with isopropanol (IPA). Therefore the tests should be done with this solvent for comparison reasons. Sometimes isopropanol is not available at customer side. Following are pressure tests which are performed with water and methanol. Modified Pressure Tests The pressure profile looks very similar to the one with isopropanol. There are little steps when the piston change there direction. This is due to the compressibility compensation setting (default 100). It is important that the slope for both pistons are parallel to each other. With methanol the pressure drop at 400 bar is larger than with isopropanol because of the lower viscosity. Figure 55 Modified Pressure Test with Water Service Handbook for 1050 Series of HPLC Modules - 11/2001 181 Pumps: Diagnostic Information Standard Pressure Tests with different Solvents Figure 56 Modified Pressure Test with Methanol With methanol the pressure drop at 400 bar is larger than with isopropanol because of the lower viscosity. Pressure Tests - Firmware Revision 1.0 The results with water and methanol are similar than the one with isopropanol. The plateaus reach approximately the same height. Also the step 6 should be in the range 300 bar to 360 bar. The test with water shows that the step 6 exceeds already the upper pressure limit (400 bar). Reason is the lower compressibility of water compared to isopropanol. 182 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Standard Pressure Tests with different Solvents Figure 57 Pressure Test (Rev. 1.0) with Water Figure 58 Pressure Test (Rev. 1.0) with Methanol Service Handbook for 1050 Series of HPLC Modules - 11/2001 183 Pumps: Diagnostic Information Standard Pressure Tests with different Solvents Pressure Tests - Firmware Revision 3.0 and above Due to the pressure controlled test the results are very similar as the one with isopropanol. The pressure drop with methanol is slightly larger. Figure 59 Pressure Test (Rev. 3.0) with Water Figure 60 Pressure Test (Rev. 3.0) with Methanol 184 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Pressure Tests when the Pump is broken The pressure plots of the 1050 Pumps are a helpful tool for troubleshooting the pumping system. Online diagnostic messages and flow related error messages should be always verified by the previous described pressure plots. This section shows examples of pressure plots for different in the factory generated failure modes. They should give indications how a possible failure looks like. The modified pressure test and the flow test method for firmware revision 1.0 and 3.0 are shown for the same failure symptom. The modified test and the flow test method should be always used together to get a clear information about the problem of the pump. Service Handbook for 1050 Series of HPLC Modules - 11/2001 185 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Pressure Tests - Leak at Piston Seal 1 Figure 61 Modified Pressure Test - Leak at Piston Seal 1 The flow is reduced to 0.1 ml/min at approximately 240 bar. From this point both piston deliver with a constant value and increase the pressure to <nobreak|320 bar|. From this point the pressure moves up to 400 bar in an oscillating curve. This means that one of the two pistons has a leak rate when delivering into the system. At the upper pressure limit (400 bar) the pressure is stable. The outlet ball valve is closed in this position and indicates that the leak is probably on the first piston side. In this case it is a defective piston seal. Firmware revision 3.0 allows to identify the leaky piston side via the current active piston display. 186 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Figure 62 Pressure Test (Rev. 1.0) - Leak at Piston Seal 1 The flow test method shows a quite normal pressure profile. Only on the slope to reach the upper limit some pressure fluctuations can be seen. The modified pressure test showed that the seal leaked at more than 320 bar. Therefore the flow test method cannot detect this defective seal. Service Handbook for 1050 Series of HPLC Modules - 11/2001 187 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Figure 63 Pressure Test (Rev. 3.0) - Leak at Piston Seal 1 The flow test method reduces the flow to 100 µl at approximately 320 bar. The pressure drops and when the piston I delivers with its small flow rate a continuous pressure drop can be observed at the first plateau. The second plateau shows a slight pressure increase and the upper limit shows stable conditions. The pressure drop at the first plateau indicates a leak on the first piston side. In this case a leaky piston seal. 188 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Pressure Tests - Leak at Piston Seal 2 Figure 64 Modified Pressure Test - Leak at Piston Seal 2 The flow is reduced to 0.1 ml/min at approximately 240 bar. From this point both piston deliver into the system with a constant rate. At 360 bar to <nobreak|370 bar| the curve is bent. With both pistons still delivering into the system the pressure cannot exceed more than 380 bar. The fact that both piston cannot increase the pressure above a certain value point to a leak on the second piston side. In this case a leaky piston seal. Service Handbook for 1050 Series of HPLC Modules - 11/2001 189 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Figure 65 Pressure Test (Rev. 1.0) - Leak at Piston Seal 2 The pressure profile shows a pressure drop at the upper limit. The modified test showed that the leak appears at more than 370 bar. Therefore the two plateaus cannot show the malfunction. At the upper limit the outlet ball valve is closed which indicates that the problem is on the second piston side. In this case the flow test method cannot clearly identify the leaky seal. The modified test is needed in addition. 190 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Figure 66 Pressure Test (Rev. 3.0) - Leak at Piston Seal 2 Both plateaus for piston 1 and piston 2 and the upper limit of the test show a certain pressure drop. Here it is very obvious that the problem is on the second piston side. In this case it is the second piston seal. Service Handbook for 1050 Series of HPLC Modules - 11/2001 191 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Pressure Tests - Defective Piston 1 Figure 67 Modified Pressure Test - Defective Piston 1 (Stroke AUTO) The pump is working with the default stroke (AUTO) setting. The flow is reduced to 0.1 ml/min at approximately 260 bar. The pressure moves up to the upper pressure limit in a oscillating curve. At the upper limit the pressure remains stable. One of the two pistons generates a small leak when delivering (pressure drop). The stable pressure line at 400 bar points to a problem on the first piston side. Firmware revision 3.0 allows to verify that the pressure drop appears on piston 1. N OT E When the piston is scratched in a certain part the failure cannot be always detected when using the default stroke setting. Therefore the test should be done also with a stroke of 100 µl. 192 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Figure 68 Modified Pressure Test - Defective Piston 1 (Stroke 100 µl) Here the pressure test has been done with a stroke of 100 µl. The pressure profile gives additional information to the previous plot. When delivering with the small flow rate the pressure increases for a long time but drops only for a relatively short time. With the currently active display of firmware revision 3.0 it can be seen that the pressure drops while the first piston is in the middle of its stroke. This indicates that the piston itself is the source of the problem. The test checks the pressure tightness of the seal over the full length of the piston. Service Handbook for 1050 Series of HPLC Modules - 11/2001 193 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Figure 69 Pressure Test (Rev. 1.0) - Defective Piston Seal 1 Before the pressure reaches the two plateaus there is always a pressure dip when the piston change there direction. Before the pressure reaches the upper limit an oscillating curve can be seen. At the upper limit the pressure is stable. All this indicates that the pump is not working correctly but it is very difficult to locate the source of the problem. 194 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Figure 70 Pressure Test (Rev. 3.0) - Defective Piston 1 The pressure increases in an oscillating curve. When exceeding 270 bar piston 2 delivers with one large stroke into the system and increases the pressure by more than 40 bar. This points already to a problem on the first piston side. Now piston 1 delivers into the system increases the pressure for a short time and then the pressure decreases for the whole plateau. The second plateau looks quite normal and also the upper value when reached after some pressure dips is stable. It is quite obvious that the problem is on the first piston side. In this case the piston is defective. Service Handbook for 1050 Series of HPLC Modules - 11/2001 195 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Pressure Tests - Defective Piston 2 Figure 71 Modified Pressure Test (Stroke AUTO) - Defective Piston 2 Even with the reduced flow of 0.1 ml/min the pistons deliver with constant rate into the system. After reaching the upper pressure value a continuous pressure drop occurs. This indicates a problem. Therefore the test was repeated with a stroke of 100 µl. 196 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Figure 72 Modified Pressure Test (Stroke 100 µl) - Defective Piston 2 This pressure profile shows a totally different behavior then the previous one. There are already pressure drops when the flow is 1.0 ml/min and the piston change there directions. When the flow is reduced to 0.1 ml/min the pressure drops with each stroke of the pistons until it is zero. With firmware revision 3.0 it can be checked that the pressure drops appear on both pistons but that the slight pressure increase is generated by piston 1. The piston is scratched in its lower part. Delivering with a small stroke volume into the system generates no problem. With the maximum flow rate of 100 µl the scratched part has to move through the seal and is obviously leaking. Service Handbook for 1050 Series of HPLC Modules - 11/2001 197 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Figure 73 Pressure Test (Rev. 1.0) - Defective Piston 2 The both pressure plateaus cannot be reached but when switching to the part where the instrument uses a stroke volume of 4 µl the pressure increases up to its normal value. At the upper limit a slight leak rate is visible. The scratches in the lower part of the piston are not visible when the pump is working with its small stroke volume. 198 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Figure 74 Pressure Test (Rev. 3.0) - Defective Piston 2 The pressure profile looks very strange. In the first part the pressure increases up to approximately 320 bar and than it drops down to about 100 bar with normal behavior of the two plateaus and afterwards an increase of the pressure to 400 bar with a slight pressure decrease at the upper limit. Before reaching the first plateau the second piston performs one large (80 µl) stroke. At this point the pressure drops. When the piston is moving only with the upper part through the seal no leak can be seen. But when the scratched part of the piston moves through the seal the system is no longer tight and the pressure drops. At the low pressure value the system is still tight and therefore the plateaus show no problem. The pump then reaches the upper limit with 250 µl and a stroke volume of 20 µl. Here the piston uses again only the unscratched part of the piston. Service Handbook for 1050 Series of HPLC Modules - 11/2001 199 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Pressure Tests - Defective Active Inlet Valve Figure 75 Modified Pressure Test - Defective Active Inlet Valve With the reduced flow rate of 0.1 ml/min the pressure increases slowly in an oscillating curve until the upper limit is reached. At the upper limit the pressure is stable pointing onto a problem on the first piston side. The actively current piston display of firmware revision 3.0 shows that the pressure drop is on the first piston side. 200 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Figure 76 Pressure Test (Rev. 1.0) - Defective Active Inlet Valve The test fails completely. The pressure in the system cannot be increased to reach the plateaus at a pressure of more than 100 bar. Also the rest of the test does not reach useful pressure values. Therefore the test provides no information about the problem in the system. N OT E In such a case the pump can be troubleshooted in the following way. Move the solvent inlet tubing out of the bottle and let the pump draw a large air bubble (for example 5 cm in the tubing). In a normal working pump the bubble will move during the intake stroke of piston 1 and will stop when the first piston is delivering into the system. If the active inlet valve is internally leaky the air bubble will move forwards during the intake stroke and the whole time backwards when the piston is delivering into the system. Service Handbook for 1050 Series of HPLC Modules - 11/2001 201 Pumps: Diagnostic Information Pressure Tests when the Pump is broken Figure 77 Pressure Test (Rev. 3.0) - Defective Active Inlet Valve Also the new version of the test fails. The pressure in the system cannot be increased to the two plateaus (>270 bar). The pressure in the system stabilizes below that value. The pump can be troubleshooted as described before. 202 Service Handbook for 1050 Series of HPLC Modules - 11/2001 8 8 Pumps: Maintenance Information This chapter provides provide procedures for service and maintenance of the 1050 Pumps Pumps: Maintenance Information This section provides information on the procedures used for maintenance replacement and alignment of assemblies in the pump. You will find procedures for: • Solvent Cabinet and Column Heater ❏ Heat Exchanger ❏ Solvent Cabinet Cable Assembly • Pump Mainframe ❏ Active Inlet Valve ❏ Outlet Ball Valve ❏ Frit Adapter Assembly ❏ Purge Valve ❏ Pump Head Assembly ❏ Continuous Seal Wash ❏ Fan ❏ Metering Drive Assembly 204 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Maintenance Information Solvent Cabinet and Column Heater Solvent Cabinet and Column Heater Replacing the Heat Exchanger ❏ Open column heater door and disconnect all capillaries from the heat exchanger. ❏ Using a flat screw driver loosen the solvent cabinet screws. ❏ Carefully take out the front panel with helium valves and manual injection valve and place on top of the solvent module. ❏ Move the insulation out of its position and take it out. ❏ Take out the plastic heat shield. ❏ Disconnect the heater flex cable from the zero insertion force connector on the cable board. N OT E Pull the outer sleeve of the connector to its front position. This releases the tension from the cable and it can be removed from the connector without problem. ❏ The heat exchanger holding screws are accessible from underneath the solvent module. Therefore move the module above the table and remove the two screws with the washers. ❏ Take the heat exchanger out of the column heater compartment. ❏ Place the new heat exchanger assembly into the column heater compartment. Place the washers onto the screws and fix the heat exchanger assembly in its position. ❏ Insert the flex cable into the zero insertion force connector and push the sleeve back to fix the cable in its position. ❏ Insert the heat shield into the compartment. ❏ Place the insulation into the heat shield and carefully press it into its position. Make sure that the parts are inserted underneath the plastic ledge at the back panel of the compartment. Service Handbook for 1050 Series of HPLC Modules - 11/2001 205 Pumps: Maintenance Information Solvent Cabinet and Column Heater ❏ Slide the front base back into its guiding slits. Assure that the front edge of the plastic heat shield is guided into the gap between the front panel and the connected metal panel. ❏ Tighten the two solvent cabinet screws. ❏ Reinstall all capillaries at the column heater assembly. Replacing the Cable Assembly ❏ Follow the above mentioned steps for replacing the heat exchanger assembly. ❏ Remove bottle tub and solvent bottles from the cabinet. ❏ Remove the front base by pushing the plastic knobs from underneath the solvent cabinet and slide it out of the instrument. ❏ Put the solvent cabinet onto the side loosen the cable holding screw at the back of the module and slide the cable out of the position. ❏ Loosen the screw which fixes the cable connector board in its position and slide the board out of the recess. ❏ Remove the tape which fixes the multi color LED. ❏ Put the solvent cabinet onto the side and move the cable assembly through the holes in the back panels to get it out of the solvent cabinet. ❏ Place the new cable assembly into the solvent cabinet that the board is located in the column heater compartment. ❏ Slide the board into its recess place the end of the cable insulation under the washer and tighten the holding screw. N OT E Do not clamp the single wires of the cable. ❏ Fix the multi color LED with a piece of tape in the groove. ❏ Reinsert the base plate and fix it with the two plastic knobs. Make sure that the LED is positioned correctly and that the cables are not clamped. N OT E The rear end of the front base must fit into the recess at the back panel of the compartment. ❏ Reinstall the heat exchanger assembly by following steps described in section replacing the heat exchanger assembly. 206 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Maintenance Information Replacing the Active Inlet Valve Replacing the Active Inlet Valve ❏ Remove the ESD cover. ❏ Disconnect the solenoid cable from the connector board. ❏ Loosen the screw which holds the shield cable and unplug the spade lug. ❏ Disconnect the active inlet valve inlet tubing. ❏ Using the supplied 12 mm wrench (8710-1841) loosen the valve and remove it. N OT E It is recommended to insert a new gold seal into the plastic cap when changing the active inlet valve. ❏ Place new inlet seal into the plastic cap and fix it onto the valve. ❏ Insert the active valve and screw it hand tight. In this position counter hold the screw with the wrench. By hand turn the solenoid itself in either direction until the capillary connection hole is about 60° to 90° away from its final position. Figure 78 Valve Final Position (Pump head disassembled) Service Handbook for 1050 Series of HPLC Modules - 11/2001 207 Pumps: Maintenance Information Replacing the Active Inlet Valve ❏ Using the 12 mm wrench tighten the screw of the valve by turning the assembly in its final position (should not be more than a quarter turn). Make sure that the ESD cover and the solvent sucking tube can be installed with the valve in its position. ❏ Fix the spade lug of the shield cable in its position and reconnect the solenoid cable to the connector board. N OT E If the active inlet valve is installed in an instrument without connection for the shield connector connect the spade lug to the holding screw of the connector board. ❏ Connect the valve inlet tube to the active inlet valve. ❏ Install the ESD cover ❏ Perform the pressure tests to verify tightness of the system. 208 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Maintenance Information Replacing the Outlet Ball Valve Replacing the Outlet Ball Valve ❏ Using the 14 mm wrench (8710-1924) loosen the valve screw and remove it. N OT E It is recommended to insert a new gold seal into the seal cap when the same valve will be used again. ❏ Before inserting a new valve check for correct center position of the cap with the gold seal. ❏ Insert the valve into the pump head and screw it hand tight. Fix the valve by turning another quarter turn with the 14 mm wrench. N OT E The plastic cover should always be installed. This prevents loosing the holding screw when disassembled and does not allow to damage the outlet ball valve by tightening at the cartridge itself. ❏ Perform the pressure tests to verify the tightness of the system. Service Handbook for 1050 Series of HPLC Modules - 11/2001 209 Pumps: Maintenance Information Maintaining the Frit Adapter Assembly Maintaining the Frit Adapter Assembly ❏ Using the 14 mm wrench (8710-1924) loosen the frit adapter assembly and remove it. ❏ Remove the cap (6) with the gold seal (5) and take out the dirty frit (4). ❏ Clean the adapter chamber from all particles. Best is to use a degreaser spray. ❏ Insert the new frit into the adapter. Ensure that the slit of the frit is facing downwards, otherwise the filter capacity is reduced. ❏ Place cap and gold seal onto adapter. N OT E It is recommended to use always a new gold seal when the frit adapter assembly was removed from the pump head. ❏ Insert the frit adapter assembly into the pump head and screw it hand tight. Fix the assembly by turning another quarter turn with the 14 mm wrench. ❏ Perform the pressure tests to verify the tightness of the pump. Figure 79 Frit Adapter Assembly 210 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Maintenance Information Maintaining the Purge Valve Maintaining the Purge Valve Changing the PTFE Frit ❏ Disconnect capillary to injector and waste tube from purge valve outlet. ❏ Using the 14 mm wrench open the purge valve at the hexagonal nut. ❏ For the next steps refer to “Maintaining the Frit Adapter Assembly” on page 210. Cleaning the Purge Valve N OT E Leaks in the purge valve can be due to particles (for example salt precipitation) between seat and ball. Therefore the cleaning procedure should be performed before replacing the whole valve. ❏ Remove the purge valve from the pump head as described before. ❏ Open the purge valve counter clockwise until the had screw (6) is loose. N OT E Do not open the securing ring on top of the hand screw and do not change the seat. ❏ Clean the upper and lower part in a ultrasonic bath using methanol or isopropanol. ❏ Re-assemble the purge valve parts and re-install purge valve. Figure 80 Purge Valve Service Handbook for 1050 Series of HPLC Modules - 11/2001 211 Pumps: Maintenance Information Maintaining the Pump Head Assembly Maintaining the Pump Head Assembly There are two different versions of the pump head available. In the latest version the spring is integrated in the plunger housing. The following table shows the serial number prefix at introduction of the new plunger housing design. Table 45 Pump Head Versions Pump SN Prefix Procedure 79851A 3447 G ..... 2 79852A/B 3447 G ..... 2 79851A 3448 A ..... 2 79852A/B 3448 A ..... 2 212 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Maintenance Information Procedure 1: Pump Head with old Plunger Housing Procedure 1: Pump Head with old Plunger Housing N OT E The pump head has two identical channels. When disassembling the pump head it is advisable not to interchange the parts of each channel for better failure identification. N OT E Since introduction of the new plunger housing design the old plunger housing parts are no longer available. The new parts are fully compatible to all existing pump heads. Stage 1: Removing the Pump Head Assembly ❏ Disconnect all four capillaries from the pump head assembly. ❏ Remove the ESD cover and disconnect the cable of the active inlet valve. ❏ Remove the two pump head screws and take out the pump head assembly. Stage 2: Disassembling the Pump Head assembly ❏ Place the assembly on the head and remove the three holding screws. ❏ Carefully separate the head from the plunger housing. C A UT I O N Do not twist the parts while separating. This could break the sapphire plunger. Service Handbook for 1050 Series of HPLC Modules - 11/2001 213 Pumps: Maintenance Information Procedure 1: Pump Head with old Plunger Housing Stage 3: Replacing the Seals ❏ Remove the two seal keeper (8) or the support seal assembly (7a). ❏ Using the three millimeter hexagonal key remove the two seals (9). ❏ Remove the two wear retainer (10). ❏ Clean the pump head chamber from all seal particles. Best is to use a degreaser spray. ❏ Place new wear retainer (10) into the pump chambers. ❏ Insert new seals (9). ❏ Place the two seal keeper (8) onto the seal. The support seal assembly will be installed onto the plunger housing. Figure 81 Pump Head Assembly 214 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Maintenance Information Procedure 1: Pump Head with old Plunger Housing Stage 4: Disassembling the Plunger Housing WA R N I N G The very strong spring will catapult the adapter up when released without holding it down. ❏ Remove the two support rings (1) or the support seal assembly. ❏ Hold the adapter (2) down on a table and loosen the setscrew (3) of one of the plungers (5). Carefully release the tension of the spring. ❏ Proceed with the second plunger in the same way. Figure 82 Plunger Housing Service Handbook for 1050 Series of HPLC Modules - 11/2001 215 Pumps: Maintenance Information Procedure 1: Pump Head with old Plunger Housing Stage 5: Reassembling the Plunger Housing ❏ Place the plunger keeper (6) on a table and insert plunger (5) and spring (4). ❏ Take the plunger housing (2) and place it on top of the spring (4). N OT E Make sure that the spring (4) does not stick before the top of the housing (2). ❏ Press the housing (2) down over the plunger keeper (6) and when flat on the table tighten the setscrew (3). N OT E The plunger keeper (6) should not stick out of the bottom of the plunger housing (2). ❏ Proceed in the same way for the second plunger. ❏ Slide the two support rings or the support seal assembly onto the plungers but do not try to press it in its position. N OT E If the support ring or the support seal assembly (1) sticks at the housing (2) carefully push the plunger from the bottom. This will center the plunger and the support ring slides into its final position. Check the alignment by lifting the support ring out of its position. Release the support ring and check that it slides back in its position without sticking. The support seal assembly should be installed onto the plungers as described before. 216 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Maintenance Information Procedure 1: Pump Head with old Plunger Housing Stage 6: Reassembling the Pump Head Assembly See Figure 81 on page 214. ❏ Prepare the head and the plunger housing as described beforehand. N OT E The seal keeper (8) should be installed on the head in front of the seals. In this position they guide the plunger into the seal and reduce the possibility of breaking the plunger during the assembling of head and plunger housing. ❏ Mount the plunger housing onto the head. The guiding pins prevent incorrect mounting. ❏ Grease the three screws with the white Teflon lubricant (79841-65501). ❏ Insert the three screws and tighten them stepwise with increased torque. Observe the slit between the two parts and make sure that they are in parallel to each other. Stage 7: Mounting the Pump Head Assembly ❏ Place the pump head assembly onto the two stay bolts of the metering drive. Make sure that no capillary sticks between pump head and metering drive. ❏ Put a light coating of white Teflon grease onto the mounting screws. ❏ Insert the two screws and tighten them crosswise. ❏ Reinstall the capillaries to the valves and the connector screw. ❏ Reconnect the active inlet valve connector and fix the shield to ground. Service Handbook for 1050 Series of HPLC Modules - 11/2001 217 Pumps: Maintenance Information Procedure 2: Pump Head with new Plunger Housing Procedure 2: Pump Head with new Plunger Housing N OT E The pump head has two identical channels. When disassembling the pump head it is advisable not to interchange the parts of each channel for better failure identification. Stage 1: Removing the Pump Head Assembly ❏ Disconnect all four capillaries from the pump head assembly. ❏ Remove the ESD cover and disconnect the cable of the active inlet valve. ❏ Remove the two pump head screws and take out the pump head assembly. Stage 2: Disassembling the Pump Head Assembly ❏ Place the assembly on the head and remove the three holding screws. ❏ Pull the block straight up from the head being careful not to put any sidewards strain on the sapphire pistons since they could shear and break. ❏ Put the plunger housing aside taking care to avoid dropping the pistons from the plunger housing. N OT E The pistons are not secured in the plunger housing and will fall out when the housing is turned upside down. ❏ Remove the pistons from the plunger housing. ❏ Check for scratches and dirt on the piston. N OT E Dirt can be removed by using a small quantity of tooth paste. 218 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Maintenance Information Procedure 2: Pump Head with new Plunger Housing Stage 3: Replacing the Seals ❏ Remove the two support seal assemblies. ❏ Using the three millimeter hexagonal key remove the two seals. ❏ Remove the two wear retainer. ❏ Clean the pump head chamber from all seal particles. Best is to use a degreaser spray. ❏ Place new wear retainer into the pump chambers. ❏ Insert new seals. ❏ Place the two support seal assemblies onto the seal. Figure 83 Pump Head Assembly (new plunger housing design) Service Handbook for 1050 Series of HPLC Modules - 11/2001 219 Pumps: Maintenance Information Procedure 2: Pump Head with new Plunger Housing Stage 4: Reassembling the Pump Head Assembly ❏ Prepare the head as described beforehand. ❏ Place the plunger housing without the pistons onto the head. ❏ Tighten the three socket head screws hand tight. N OT E Tightening the screws fully will require much more force to insert the pistons into its position in the seals. ❏ Insert the pistons into the assembly and carefully push it into the seal. ❏ Tighten the three screws stepwise with increasing torque. Make sure that the head and plunger housing surfaces are in parallel. Stage 5: Mounting the Pump Head Assembly ❏ Place the pump head assembly onto the two stay bolts of the metering drive. Make sure that no capillary sticks between pump head and metering drive. ❏ Put a light coating of white Teflon grease onto the mounting screws. ❏ Insert the two screws and tighten them crosswise. ❏ Reinstall the capillaries to the valves and the connector screw. ❏ Reconnect the active inlet valve connector and fix the shield to ground. 220 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Maintenance Information Continuous Seal Wash Option Continuous Seal Wash Option N OT E The previous described procedures for the pump heads are also applicable for the seal wash option. This procedure will only describe the secondary seal replacement. ❏ Remove the pump head assembly and disassemble it following stage 1 and stage 2. ❏ Remove the two support rings from the plunger housing. ❏ Remove the gasket from the support ring. ❏ Using the tool from the upgrade kit (01018-23702) remove the wash seal. ❏ Place the new seal onto the tool and insert the new wash seal into the support ring. Ensure that the wash seal clicks into place in the support ring. Figure 84 Pump Head with continuous seal wash Service Handbook for 1050 Series of HPLC Modules - 11/2001 221 Pumps: Maintenance Information Replacing the Fan Replacing the Fan ❏ Remove the top cover. ❏ Disconnect the fan cable at the motherboard. ❏ Lift the foam part at the left side of the module and slide it out to the front. ❏ Carefully remove the fan from the foam part (one edge after the other). N OT E In case it is not possible to get the fan out of the foam cut the foam part at the back side between the two naps. ❏ With the blade of a screwdriver separate the protection cover from the fan. ❏ Insert the new fan into the foam part. The air stream should be into the module (arrow pointing down). Cable should show to the back. ❏ Place the fan protection cover onto the new fan. ❏ Place the foam part into its place. N OT E The foam part must be inserted into the chassis and must be replaced close to the back panel. Make sure that the upper foam part fits behind the ridge of the bottom part. It might be more convenient to replace the foam part when the motor plug is disconnected. 222 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Maintenance Information Removing the Metering Drive Assembly Removing the Metering Drive Assembly ❏ Remove the pump head assembly. ❏ Remove the top cover. ❏ Remove the foam part with the fan. ❏ Disconnect the three cable of the metering drive. ❏ Unscrew the three holding screws of the base of the metering drive. N OT E The third screw is accessible through the bottom foam part. ❏ Move the motor of the metering drive out of the foam part and take it out. Service Handbook for 1050 Series of HPLC Modules - 11/2001 223 Pumps: Maintenance Information Removing the Metering Drive Assembly 224 Service Handbook for 1050 Series of HPLC Modules - 11/2001 9 9 Pumps: Parts Information This chapter provides information on parts of the 1050 Pumps Pumps: Parts Information This chapter gives complete parts listings and exploded views for the HP 1050 (Ti) Pumps. • Electronic Boards • All Ti - Parts • Solvent Cabinet • Overall Diagram • Flow Path • Metering Drive Assembly • Pump Head Assemblies • Active Inlet Valve • Outlet Ball Valve • Frit Adapter Assembly • Purge Valve Assembly • Special Tools 226 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Electronic Boards Electronic Boards For fuses refer to Table 47 on page 228. Table 46 Electronic Boards Item Description Part Number 1 Power Supply Board DPS-B 5061-3374 2 Pump Drive Control 2 Board PDC2 Exchange PN 01050-69374 01018-66532 # U 78 MC78L15ACP 1826-0274 # U 79 MC79L15ACP 1826-0281 3 Relative A/D Converter RAD 01018-66503 01018-69503 4 Firmware Board SFW 01018-66506 5 Heater Isocratic Board HRI 01018-66517 6 Heater Quaternary Board HRQ 01018-66518 01018-69518 7 Communication Interface Board CIB 5061-3382 01050-69582 8 Common Main Processor Board CMP 5061-3380 01050-69580 9 Fluorescent Indicator Module FIP 5061-3376 10 Connector Board CON 01018-66505 11 Motherboard HPS 01018-66501 # U 78 and U 79 have to be replaced when a new metering device 01018-60001/-69100 (parts included) is installed in a pump with PDC board revision A. Service Handbook for 1050 Series of HPLC Modules - 11/2001 227 Pumps: Parts Information Electronic Boards Table 47 Fuses Description Board Part Number Fuse 110V operation (3 A) DPS-B 2110-0003 Fuse 220V operation (2 A) DPS-B 2110-0002 Fuse F16 (PDC); F481 (PDC2) 1.5 A PDC2 2110-0304 Fuse F891, F892 on board 500 mA PDC 2110-0934 Fuse F112, F113 on board 500 mA PDC2 2110-0934 Fuse F12, F22 250 mA RAD 2110-0004 Fuse F4 2.5 A HRI, HRQ 2110-0083 Fuse F15 1 A HRQ 2110-0007 Fuse ICP1 1 A FIP 2110-0099 Fuse F1 375 mA CON 2110-0421 228 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Complete List of Ti-Parts Complete List of Ti-Parts Table 48 Complete List of Ti-Parts Description Part Number Description Part Number Ti - Pump Head Assembly 01019-60002 Ti - Capillary ID 0.17 35 cm lg 01019-87608 Ti - Pump Chamber Housing 01019-25205 Ti - Active Inlet Valve 01019-60010 Accessories Ti - Piston Seal 0905-1199 PCTFE - Adapter 5021-1872 Ti - Damping Unit 01019-60005 Ti - MCGV 01019-67701 Ti - Maintenance Kit 01019-68724 Ti - Manual Injection Valve obsolete includes: Ti - Rotor Seal Tefzel 0101-0620 Ti - Piston Seal (2x) 0905-1199 Ti - Stator 0101-0663 PTFE Frits 5/PK 01018-22707 Ti - Loop Capillary 20 µl 0101-0655 Gasket Seal Wash (2x) 6/pk 5062-2484 Ti - Bottle Head Assembly obsolete Seal Wash (2x) 0905-1175 Ti - Bushing 01019-21734 Seal Gold Outlet (5x) 5001-3707 Solvent Glass Filter Adapter 5041-2168 5062-8517 Cap Outlet (5x) 4/pk 5042-1346 Ti - He - Sparge Assembly 01019-82702 Ti - Screw Tube 01019-23232? Ti - High Pressure Solvent Filter Kit 01019-68709 Ti - Name Plate includes: Ti - Capillary Piston 1 260 mm lg 01019-67301 Ti - Capillary ID 0.25 13 cm lg 01019-87308 Ti - Capillary Piston 2 210 mm lg 01019-67302 Ti - Fitting Insert (2x) 01019-27601 Ti - Tubing ID 0.25 mm 700 mm lg 01019-67305 Fitting Nut (1x) 79900-25701 Ti - Sucking Tube see item 13 Fitting Screen (1x) 79900-22401 Fitting Insert (1x) 01019-27601 Service Handbook for 1050 Series of HPLC Modules - 11/2001 229 Pumps: Parts Information Solvent Cabinet Solvent Cabinet Table 49 Solvent Conditioning Module Item Description Part Number Item Description Part Number 1 Solvent Compartment incl. (2) 01018-60019 11 Holder He-Valves 01018-05501 2 Bottle Tub no PN 12 Washer 5001-3746 3 Front Panel no PN 13 Screw 0624-0045 Cover Cap, no injection valve 6960-0024 14 Injector Tub 01018-44503 Cover Cap, no Helium on/off valve 6960-0027 15 Screw M3 4 mm lg 0515-1508 16 Capillary ID 0.17 400 mm lg 79826-87608 16 Ti - Capillary ID 0.17 35 cm lg 01019-87608 Cover Cap, no Helium Regulators 6960-0028 4 Front Base 01018-40512 5 Oven Door 01018-60302 6 Bolt 01018-43701 7 Door Hinge 01018-45101 Angle Injection Position (part of Sensor Assembly) 01018-00511 8 Name Plate 5041-2170 Sensor Assembly 5062-2432 Screw lock female (2x) 1251-7788 Washer M4 (2x) 3050-0893 9 Tubing Flexible ID 4 mm OD 5 mm 10 Funnel Leak 01018-43211 230 17 Accessory Kit, includes following 01018-68704 items Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Solvent Cabinet Figure 85 Solvent Cabinet Service Handbook for 1050 Series of HPLC Modules - 11/2001 231 Pumps: Parts Information Solvent Cabinet with Helium Degassing Solvent Cabinet with Helium Degassing Table 50 Solvent Cabinet with Helium Degassing Item Description Part Number Item Description Part Number 1 Solvent Compartment, incl. (2) 01018-60019 14 Solvent Bottle, 1 liter 9301-0656 2 Front Panel no PN 15 Bottle Head Assembly, includes item 16 to 25 01018-60017 3 Holder He-Valves 01018-05501 15 Ti - Bottle Head Assembly, includes item 16 to 25 01019-60017 4 Screw 0624-0045 16 Bottle Head Cap 01018-44111 5 Washer 5001-3746 17 Bottle Head Shaft 01018-43711 6 Regulator Knob A 01018-47413 18 Bottle Head Washer 01018-48811 Regulator Knob B 01018-47414 Regulator Knob C 01018-47415 19 Connector Helium Sparger (6/pk) 5062-8515 Regulator Knob D 01018-47416 20 Helium Sparger 10-16 µl 5041-8339 7 Knob On/Off 01018-47412 21 Solvent Filter SST 01018-60025 8 Helium Regulator Assembly, includes item 6 an 7 01018-67001 21 Solvent Glass Filter Adapter 5041-2168 5062-8517 9 Tubing PTFE ID 1/16” OD 1/8” 0890-0746 22 Tube Bushing Teflon 79835-21734 10 Fitting 0100-1430 22 Ti - Bushing 01019-21734 11 Tubing Flexible ID 0,156” 0890-0581 23 Tube Screw 5041-2163 12 Fitting 0100-1047 24 Tubing FEP ID 1.5 mm OD 3 mm 5 m 5062-2483 25 Tubing PTFE ID 1.45 mm OD 2.5 mm 5 m 5062-2461 Filter Disc (part of 12) 13 Air Tubing Flexible 5 m 232 Helium Sparge Assembly, includes item 19 and 20 01019-82702 5021-7127 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Solvent Cabinet with Helium Degassing Figure 86 Solvent Cabinet with Helium Degassing Service Handbook for 1050 Series of HPLC Modules - 11/2001 233 Pumps: Parts Information Solvent Cabinet with Column Heater and Manual Injection Valve Solvent Cabinet with Column Heater and Manual Injection Valve Table 51 Solvent Cabinet with Column Heater and Manual Injection Valve Item Description Part Number 1 Solvent Compartment, incl. (2) 01018-60019 2 Front Panel no PN 3 Plug 4 Item Description Part Number Rheodyne Valve 7125 complete, includes item 22 to 29 0101-0607 22 Isolation Seal 1535-4046 01018-44103 23 Rotor Seal Vespel 0101-0623 Cable Assembly Heater 01018-61600 23 (Ti) Rotor Seal Tefzel (high pH) 0101-0620 5 Washer 5001-3746 24 Stator Face Assembly no PN 6 Screw M4 6 mm lg 0515-0915 25 Stator (Head) 1535-4044 7 Heater Assembly 01018-66901 25 Ti - Stator (Head) 0101-0663 8 Washer 3050-0893 26 Loop Capillary 20µl 0101-0377 9 Screw M3 16 mm lg 0515-0986 26 Ti - Loop Capillary 20 µl 0101-0655 10 Insulation 01018-45401 27 Stator Screw 1535-4857 11 Heat Shield 01018-40601 28 Connector Capillary no PN 12 Front Base 01018-40512 29 Valve Transport Protection no PN 13 Oven Door 01018-60302 30 Capillary ID 0.17 400 mm lg 79826-87608 14 Bolt 01018-43701 30 Ti - Capillary ID 0.17 35 cm lg 01019-87608 15 Door Hinge 01018-45101 31 Tubing ID 0.25 mm 700 mm lg 01018-67305 16 Waste Vial 9301-1168 31 Ti - Tubing ID 0.25 mm 700 mm lg 01019-67305 17 Vial Holder 01018-44901 32 Sensor Assembly 5062-2432 18 Holder He-Valves 01018-05501 33 Remote Cable 5061-3378 19 Screw 0624-0045 Syringe 25 µl 9301-0633 20 Washer 5001-3746 Needle 10-100 µl 9301-0679 21 Angle Injection Position 01018-00511 234 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Solvent Cabinet with Column Heater and Manual Injection Valve Figure 87 Solvent Cabinet with Column Heater and Manual Injection Valve Service Handbook for 1050 Series of HPLC Modules - 11/2001 235 Pumps: Parts Information Overall Diagram Overall Diagram Table 52 Overall Diagram Item Description Part Number Item Description Part Number 1 Fan Grill 3160-0544 35 Screw (plastic) for MCGV 0515-1256 2 DC Fan 01048-68500 36 no longer used no PN 3 Cooling Drain 01018-47706 37 no longer used no PN 4 Push Button, white 5041-1203 38 no longer used no PN 5 Power Actuator 5041-2162 39 Leakage Tray right 01018-44502 6 Spring Compression 1460-1510 40 High Pressure Damper 79835-60005 7 Cover Hinge 5041-2147 41 Active Inlet Valve 01018-60010 8 Sheet Metal Kit 01018-68701 42 Frit Adapter Assembly 01018-60007 9 Foot Front 5041-2161 42 Purge Valve G1311-60009 10 Cable to Connector Board 5062-2416 43 Adapter short 01018-23207 11 Connection Tube 150 mm lg G1311-67304 44 Outlet Ball Valve G1311-60008 12 MCGV Exchange 79835-67701 79835-69701 45 Metering Drive Assembly 01018-60001 13 Connector Board 01018-66505 46 Pump Head Assembly includes item 41 to 44 01018-60004 14 Front Plate 01018-04106 47 Pump Plate 01018-04704 15 Leakage Tray, left 01018-44501 48 Capillary Piston 1 ID 0.5 27 cm lg 01018-67309 16 Leak Sensor 5061-3356 49 Capillary Piston 2 ID 0.5 21 cm lg 01018-67302 17 Logo Base 5041-2144 50 Power Supply (DPS-B) Exchange 5061-3374 01050-69374 18 Name Plate 5041-2170 51 PDC2 Board 01018-66532 19 Front Door 01018-60301 52 SFW Board (Firmware) 01018-66506 20 Power Switch Base 5041-2145 53 RAD Board Exchange 01018-66503 01018-69503 236 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Overall Diagram Table 52 Overall Diagram Item Description Part Number Item Description Part Number 21 ESD Cover 01018-44106 54 HRI Board 01018-66517 22 Cover Keyboard 5001-3736 54 HRQ Board 01018-66518 23 Leak Assembly, includes item 24, 5062-8551 25, 26 56 Motherboard 01018-66501 27 Keyboard Module 01018-60201 57 Cover Plate P/S 5001-3728 28 Fluorescent Interface 5061-3376 58 Top Cover 5001-3724 29 Cable to Display Board 5061-3400 59 Plate Cover, 1.5 inch 5001-3722 30 Screw M3.5 6 mm lg 0515-0889 60 Plate Cover, 1.3 inch 5001-3721 31 Bumper 0403-0427 61 Card Cage no PN 32 Screw M4 6 mm lg 0515-0898 62 Screw M3.5 6 mm lg also for AIV ground cable 0515-0887 33 Screw M4 20 mm lg (special) 0515-1918 34 Screw M3 8 mm lg 0515-0912 Screw, ESD cover Service Handbook for 1050 Series of HPLC Modules - 11/2001 5021-1862 237 Pumps: Parts Information Overall Diagram Figure 88 Overall Diagram Part 1 238 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Overall Diagram Figure 89 Overall Diagram Part 2 (Pars II) Service Handbook for 1050 Series of HPLC Modules - 11/2001 239 Pumps: Parts Information Hydraulic Flow Path Hydraulic Flow Path Table 53 Hydraulic Flow Path Quaternary Pump Item Description Part Number 1 Drawing Tubing consists of Item Description Part Number no PN Gripper MCGV 0100-1431 Solvent Filter SST 01018-60025 Connector MCGV 0100-1432 Helium Sparger 10-16 µl 5041-8339 Ferrule, inlet valve 20/pk 5061-3321 Connector Helium Sparger (6/pk) 5062-8515 Gripper, inlet valve 20/pk 5061-3322 Tubing FEP ID 1.5 mm OD 3 mm 5 m 5062-2483 Male, inlet valve 20/pk 5061-3323 Tube Bushing Teflon 79835-21734 Buffer Disc, inlet valve 40/pk 5061-3324 Screw Tube 5041-2163 3 Capillary Piston 1 ID 0.5 27 cm lg 01018-67309 3 Ti - Capillary Piston 1 260 mm lg 01019-67301 1 Ti - Drawing Tubing, consists of no PN 4 Capillary Piston 2 ID 0.5 21 cm lg 01018-67302 Solvent Glass Filter Adapter 5041-2168 5062-8517 4 Ti - Capillary Piston 2 210 mm lg 01019-67302 Tubing FEP ID 1.5 mm OD 3 mm 5 m 5062-2483 5 Tubing ID 0.25 mm 700 mm lg Ti - Bushing 01019-21734 5 Ti - Tubing ID 0.25 mm 700 mm lg 01019-67305 Screw Tube 5041-2163 6 Teflon Tubing ID 1 mm OD 3 mm 0890-1764 G1311-67304 7 Tubing PTFE ID 1.45 mm OD 2.5 mm 5 m 2 Connection Tube, consists of 01018-67305 5062-2461 Flex Tubing PTFE ID 0.7 mm5 m lg 5062-2462 240 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Hydraulic Flow Path Table 54 Hydraulic Flow Path Isocratic Pump Item Description Part Number 2 Drawing Tubing, consists of 01018-67303 Item Description 2 Ti - Drawing Tubing, consists of Part Number 01019-67303 Solvent Filter SST 01018-60025 Solvent Glass Filter Adapter 5041-2168 5062-8517 Tubing FEP ID 1.5 mm OD 3 mm 5 m 5062-2483 Tubing FEP ID 1.5 mm OD 3 mm 5 m 5062-2483 Nut 79835-25731 Nut 79835-25731 Screw Tube 79835-23231 Ti - Screw Tube 01019-23232 Service Handbook for 1050 Series of HPLC Modules - 11/2001 241 Pumps: Parts Information Hydraulic Flow Path Figure 90 Hydraulic Path 242 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Metering Drive Assembly Metering Drive Assembly Table 55 Metering Drive Assembly Item Description Part Number Item Description 01018-60001 5 Bumper 5021-1839 01018-69100 6 Screw M3.5 8 mm lg 0515-0887 1 Cover 01018-44102 7 Pump Plate 01018-04704 2 Screw M2.5 6 mm lg 0515-0894 8 Screw M4 5021-1841 4 Stay Bolt 01018-23704 3 Metering Drive Assembly Exchange Assembly, includes item 1, 2, 4, U78 and U79 for PDC board rev. A Figure 91 Part Number Metering Drive Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 243 Pumps: Parts Information Pump Head Assembly (old version) Pump Head Assembly (old version) Table 56 Pump Head Assembly (old version) Item Description Part Number Complete Assembly Item Description 01018-60004 1 Plunger Keeper Part Number 11 Pump Chamber Housing 01018-25203 12 Screw M5 50 mm lg 0515-1220 2 Sapphire Plunger 5063-6586 13 Active Inlet Valve 01018-60010 3 Spring Compression 1460-2220 14 Adapter short 01018-23207 4 Screw M4 40 mm lg 0515-0850 15 Outlet Ball Valve G1311-60008 5 Plunger Housing see page 245 6 Set Screw M3 8 mm lg 0515-1917 Tools 7 Support Seal Assembly 5001-3739 Wrench 12 mm 8710-1841 8 Seal Keeper part of (7) Wrench 14 mm 8710-1924 9 Plunger Seal (2/Pk) 5063-6589 Insert Tool Seals 01018-23702 5064-8249 Teflon Grease 79841-65501 10 Wear Retainer (10/pk) Figure 92 Pump Head Assembly (old version 244 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Pump Head Assembly (new version) Pump Head Assembly (new version) Table 57 Pump Head Assembly (new version) Item Description Part Number Complete Assembly 01018-60004 Item Description 9 Adapter short Part Number 01018-23207 1 Sapphire Plunger 5063-6586 10 Active Inlet Valve 01018-60010 2 Screw M4 40 mm lg 0515-0850 11 Screw M5 50 mm lg 0515-1220 3 Plunger Housing 01018-60006 Tools 4 Support Seal Assembly 5001-3739 Wrench 12 mm 8710-1841 5 Plunger Seal (2/Pk) 5063-6589 Wrench 14 mm 8710-1924 6 Wear Retainer (10/pk) 5064-8249 Insert Tool seals 01018-23702 7 Outlet Ball Valve G1311-60008 8 Pump Chamber Housing 01018-25203 Teflon Grease 79841-65501 Figure 93 Pump Head Assembly (new version) Service Handbook for 1050 Series of HPLC Modules - 11/2001 245 Pumps: Parts Information Pump Head Assembly with Seal Wash Pump Head Assembly with Seal Wash Table 58 Pump Head Assembly with Seal Wash Item Description Part Number Item Description Part Number Complete Assembly 01018-60005 17 Sapphire Plunger 5063-6586 Ti - Complete Assembly 01019-60002 18 Plunger Keeper no PN 1 Screw M5 50 mm lg 0515-1220 19 Plunger Housing 01018-60006 2 Active Inlet Valve 01018-60010 2 Ti - Active Inlet Valve 01019-60010 Tools 3 Adapter short 01018-23207 Wrench 12 mm 8710-1841 4 Pump Chamber Housing 01018-25203 Wrench 14 mm 8710-1924 4 Ti - Pump Chamber Housing 01019-25205 Insert Tool, seals 01018-23702 5 Outlet Ball Valve G1311-60008 Teflon Grease 79841-65501 6 Wear Retainer (10/pk) 5064-8249 7 Plunger Seal (2/Pk) 5063-6589 Accessories 7 Ti - Seal 0905-1199 8 Seal Keeper 5001-3743 Seal Wash Option Update Kit includes tubing, seals (2x), support ring (2x) and items # 9 Gasket, seal wash (6/Pk) 5062-2484 # Syringe 9301-0411 10 Seal Wash 0905-1175 # Adapter Luer (3x) 0100-1681 11 Support Ring Seal Wash 5062-2465 # Abrasive Paper TP 240 01018-68722 12 Teflon Tubing ID 1 mm OD 3 mm 0890-1764 # Insert Tool Seal 01018-23702 13 Set Screw M3 8 mm lg 0515-1917 # Seal Keeper (item 8) (2x) 5001-3743 14 Plunger Housing (old version) order 19 15 Screw M4 40 mm lg 0515-0850 Velocity Regulator (3/pk) 5062-2486 16 Spring Compression 1460-2220 246 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Pump Head Assembly with Seal Wash Figure 94 Pump Head Assembly with Seal Wash Service Handbook for 1050 Series of HPLC Modules - 11/2001 247 Pumps: Parts Information Active Inlet Valve Active Inlet Valve Table 59 Active Inlet Valve # Description Figure 95 Part Number AIV Assembly, complete 01018-60010 Ti - AIV Assembly, complete 01019-60010 1 Cap Inlet Valve 01018-21207 2 Gold Seal 5001-3708 3 Retainer Ring, gold coated 5021-1874 Active Inlet Valve 248 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Outlet Ball Valve Outlet Ball Valve Table 60 Outlet Ball Valve # Description Figure 96 Part Number Outlet Ball Valve Assembly, complete G1311-60008 Ti - Outlet Ball Valve Assembly, complete 01018-60032 1 Socket Cap 5042-1345 2 Housing Screw 01018-22410 3 Outlet Valve Cartridge no PN 4 Gold Seal, Outlet 5001-3707 5 Cap 5062-2485 Outlet Ball Valve Service Handbook for 1050 Series of HPLC Modules - 11/2001 249 Pumps: Parts Information Frit Adapter Assembly Frit Adapter Assembly Table 61 Frit Adapter Assembly # Description Frit Adapter Assembly, complete Figure 97 Part Number 01018-60007 1 O-ring (12/Pk) 5180-4167 2 Housing Screw 01018-22410 3 Adapter 01018-23209 4 PTFE Frit (5/Pk) 01018-22707 5 Gold Seal 5001-3707 6 Cap (4/pk) 5062-2485 Frit Adapter Assembly 250 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Purge Valve Assembly Purge Valve Assembly Table 62 Purge Valve Assembly # Description Purge Valve Assembly, complete Figure 98 Part Number G1311-60009 1 Gold Seal 5001-3707 2 Cap (4/pk) 5062-2485 3 PTFE Frit (5/Pk) 01018-22707 4 Tubing PTFE ID 1.45 mm OD 2.5 mm 5 m 5062-2461 Purge Valve Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 251 Pumps: Parts Information Column Holder Assembly Column Holder Assembly Table 63 Column Holder Assembly # Description Column Holder Assembly Figure 99 Part Number 5062-2469 1 Holder Brass no PN 2 Stand 5001-3738 3 Clamp no PN 4 Support Block no PN Column Holder Assembly 252 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Parts Information Special Tools Special Tools Table 64 Special Tools # Description Part Number Wrench, 12 mm 8710-1841 Wrench, 14 mm 8710-1924 Insert Tool, Seals 01018-23702 Teflon Grease 79841-65501 Service Handbook for 1050 Series of HPLC Modules - 11/2001 253 Pumps: Parts Information Special Tools 254 Service Handbook for 1050 Series of HPLC Modules - 11/2001 10 10 Pumps: Additional Information This chapter provides additional information about the 1050 Pumps Pumps: Additional Information This section gives information about: • Pumps Prefix History • Pumps Firmware History • Online Monitor • Operational Hints • Helium Degassing Principle • Isocratic Pumps • Pump Head Assembly • PDC Board • HRQ Board • Wear Retainer • Outlet Ball Valve • Flow Test Method • Method Loading • Flow Gradients • Manual Injection Valve 256 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Additional Information Product History Product History Since introduction of the 1050 Pumps in 1988 a couple of hardware and firmware changes have been implemented in production. With most of this changes the serial number prefix has been changed too. Following is a list of all prefix changes done in Waldbronn and Little Falls. Table 65 Product History 79851A and 79852A/B S/N Prefix Changes 2813 G ..... Introduction of the 1050 Pumps 2913 G ..... ESD cover added to the gradient valve. Hardware changes of extrusion and holding bracket for the MCGV. 2949 G ..... 2949 A..... Wear retainer installed in front of each seal. 3010 G ..... 3012 A ..... Introduction of the current pump head version. In the meantime all old pump heads have been updated. 3016 G ..... 3019 A ..... Introduction of firmware revision 3.0 and introduction of column heater. Introduction of HRI/HRQ Board (HRQ replaces GVD board). 3031 G ..... 3034 A ... (51A) or Introduction of firmware revision 3.1 3032 A ... (52A) 3045 G ..... Purge Valve added to all quaternary pumps 3106 G ..... 3106 A ... (51A) or New voltage regulators on PDC board (rev B), 3107 A ... (52A) exchange metering drives require a PDC update. 3117 G ..... 3117 A ... (51A) or Introduction of firmware revision 3.2 3118 A ... (52A) 3206 G ..... Introduction of dedicated seal and hardware modifications of pump chamber and seal keeper 3243 G .....3244 A...(51A) or 3145 A...(52A) Introduction of PDC2 board. Service Handbook for 1050 Series of HPLC Modules - 11/2001 257 Pumps: Additional Information Product History Table 65 Product History 79851A and 79852A/B S/N Prefix Changes 3312 G ..... Integrated spindle for metering drive assembly 01018-60001 3334 G ..... Support seal assembly replaces support ring and seal keeper 3404 G ..... 3404 A ... (51A) or Introduction of Damper with new pressure sensor and 3405 A ... (52A) electronic board (Rev. G) Table 66 3447 G ..... 3448 A ..... Spring integrated in plunger housing June 1996 Active Inlet Valve with Exchangeable Valve Cartridge March 1998 Plunger Housing with new springs available November 1998 Part Number Change for DC-Fans September 2001 End of Support of 1050 Isocratic Pump 79851B TI ends September 30, 2001 Product History Solvent Cabinet S/N Prefix Changes 3019 G ..... Solvent Cabinet 79856A/B serialized 3205 G ..... Improvement of Helium Regulators; better regulation range and tightening behavior. 3216G... Modification of Bottle Head Shaft of the Bottle Head Assembly. 258 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Additional Information Firmware History Firmware History Revision 1.0 Revision 1.0 was the firmware at introduction of the 1050 Pumps. Known Problems In purge mode flow values above 5 ml/min will not be shown on the display. At higher values the display remains at 5 ml/min but the pump is purging with the set value. Revision 3.0 Europe/ICON SN 3016 G..... US/Canada SN 3019 A ..... Revision 3.0 incorporates: • Communication with the GPIB communication interfaces. • Support of the column heater. • Improved flow test method. Known Problems 1 If a gradient test method is started directly after running the build in flow test method the gradient might be distorted. Switching the pump off and on again after a pressure test solves the problem. 2 For applications with system pressures below 30 to 40 bar the lower pressure limit is not applicable. 3 Internal tests of the DOS workstation (Phoenix) revealed a couple of bugs in the communication part of the firmware. Service Handbook for 1050 Series of HPLC Modules - 11/2001 259 Pumps: Additional Information Firmware History Revision 3.1 Europe/ICON SN 3031 G..... US/Canada SN 3034 A ..... (for 79851A/B) SN 3033 A ..... (for 79852A/B) This firmware revision fixes the bugs encountered with the ChemStation. Known Problems Due to an internal timing problem relay contact 1 and 2 may switch incorrectly when used together in the timetable. Relay contact 2 might be activated together with contact 1 even when the timetable shows only an entry for contact 1. Revision 3.2 Europe/ICON SN 3117 G..... US/Canada SN 3117 A ..... This revision fixes the known bug of firmware revision 3.1. 260 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Additional Information How does the On-line Monitor work How does the On-line Monitor work The online monitor is part of the 1050 Pump firmware and checks the performance of the metering pump. The online Monitor detects appearing leaks 1st piston leak valve problems valve backflow and checks via the pressure ripple for gas bubbles in the system gas bubble. N OT E The online monitor is a user selectable function and can be enabled or disabled via the diagnose level in the configuration displays. The online monitor is only active if the pressure in the pump is above 50 bar. DIAGNOSIS LEVEL 0 disables the online monitor and none of the following messages will be generated. DIAGNOSIS LEVEL 1 turns the online monitor on. Any measured deviation from the normal operation modes will generate an entry in the logbook. DIAGNOSIS LEVEL 2 comprises the same functions like level 1 and in addition lids the not ready LED at the keyboard. The remote output shows the not ready condition and disables further injections when connected to the 1050 Autosampler. DIAGNOSIS LEVEL 3 is used for factory adjustment of the metering drive. Service Handbook for 1050 Series of HPLC Modules - 11/2001 261 Pumps: Additional Information How does the On-line Monitor work Normal Operation The figure below shows the normal pressure profile of the instrument. The curve is ideal and can only be recorded with a very fast transient recorder. A normal integrator (339X) is too slow to record the very fast changes of the curve and shows a smoothed one. However occurring operation problems can be also seen on a integrator plot. During the delivering strokes of the two pistons the instrument measures the pressure at the points D1 to D10. Failure conditions like leaks or gas bubbles influence the pressure curve from which the processor can determine certain failure modes. Figure 100 Online Diagnostic: Normal Operation 262 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Additional Information How does the On-line Monitor work M2 Gas Bubble The following figure shows the pressure profile when a gas bubble was drawn from the bottle. During the delivery phase of piston I the gas bubble will be compressed first before solvent can be delivered into the second chamber. This means the pressure will drop during the compression phase of the air bubble before it returns to normal behavior. The pressure profile of the second piston shows no deviation. The pressure drop at the beginning of the stroke generates a higher pressure ripple which is used to determine a gas bubble problem. The pressure ripple is depending on various parameters like solvent, flow, compressibility and so on. For this reasons the pressure ripple has to exceed a certain range before a gas bubble can be detected. The relation between pressure ripple and compressibility setting is shown in the respective figure. N OT E Drastic pressure changes (for example suddenly no more solvent to pump due to empty bottle) can not be detected under all circumstances. To make sure that the system will stop in such a case (for example running out of solvent during an unattended sequence) a lower pressure limit should be set. Figure 101 Online Diagnostic: Gas Bubble Service Handbook for 1050 Series of HPLC Modules - 11/2001 263 Pumps: Additional Information How does the On-line Monitor work Figure 102 Online Diagnostic: Compressibility vs. Pressure Ripple 264 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Additional Information How does the On-line Monitor work M4 Leak at first Piston The following figure shows the pressure profile when the system is leaky either at the inlet valve or at the piston seal. The delivery stroke of piston I shows a pressure drop while piston II delivers without any problems. Figure 103 1050 Online Diagnostic: Leak at first piston Service Handbook for 1050 Series of HPLC Modules - 11/2001 265 Pumps: Additional Information How does the On-line Monitor work M6 Valve Backflow The following figure shows the pressure profile when the outlet ball valve is not working correctly. Delivery stroke of piston I shows normal behavior while during the stroke of piston II the pressure drops because of the internally leaking ball valve. Figure 104 Online Diagnostic: Outlet Ball Valve Backflow 266 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Additional Information How does the On-line Monitor work M8 Outlet Valve Problem The following figure shows the pressure profile when the outlet valve sticks in its position. During the delivery stroke of piston II the pressure drops because a sticky ruby ball needs longer time to be closed. Figure 105 Online Diagnostic: Outlet Ball Valve Service Handbook for 1050 Series of HPLC Modules - 11/2001 267 Pumps: Additional Information If You Need Operational Hints If You Need Operational Hints You will find general information about the pumps and certain parts followed by description of known behaviors of the instrument. This section gives information about: • Helium Degassing Principle • Helium Regulators • Isocratic Pumps • Pump Head Assembly • PDC Board • HRQ Board • Wear Retainer • Outlet Ball Valve • Flow Test Method • Method Loading • Flow Gradients • Manual Injection Valve 268 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Additional Information If You Need Operational Hints Helium Degassing Principle The Helium degassing works in two stages. First, replacing the dissolved gas in the solvent. Helium streams through the solvent and replaces the air dissolved. So after some time the solvent is saturated with Helium. Second, prevent that air diffuses back into the solvent. The compartment above the solvent will also be filled with Helium. The Helium above the solvent is absolutely necessary to make sure that no air can be introduced back into the solvent. So the bottle head has to be in its position otherwise the degassing will not work or it will require a too high Helium stream through the solvent. N OT E If the vent position of the bottle head is connected to a fume hood, make sure that the Helium is not sucked out of the bottle. Best is to install a restriction (for example change diameter from 1/4" to 1/8") to make sure that the Helium blanket above the solvent surface remains in its place. Otherwise performance problems especially with gradient runs or excessive high Helium consumption might be the result. Helium Regulators The helium regulators allow the regulation of the helium flow. The regulator design does not allow to set the helium stream to zero. A small flow of helium is still possible. Service Handbook for 1050 Series of HPLC Modules - 11/2001 269 Pumps: Additional Information If You Need Operational Hints Bottle Head Assembly During the lifetime of the solvent cabinet a problem with the bottle head assembly was encountered. The helium leaves the bottle head assembly through the vent connector. To reach this vent the helium has to pass the bottle head shaft. The helium passes through the gaps between the holes in the shaft and the supply tubings for helium and solvent. Variations in the tolerances for hole size and tubing diameter may restrict the helium flow out of the solvent bottle. This may cause the effect that the solvent gets oversaturated with helium. Oversaturation may lead to problems in pump and detector. For that reason the bottle head assemblies have been modified with a separate vent hole (1 mm to 2 mm in diameter) to the bottle head shaft (01018-43711). All solvent cabinets 79856A/B with serial number prefix 3216 G... and greater will have the modification installed. Instruments without the vent hold should be updated. Using a screwdriver simply punch a hole of 1 mm to 2 mm diameter in the shafts of the bottle head assemblies (01018-43711). Isocratic Pumps Isocratic pumps are often sold without the solvent conditioning module option. The bottle is then placed beside the instrument. Tests have shown that best results in regards of pressure ripple stability, air sensitivity and so on are reached when the solvent bottle is placed on top of the module or even higher (for example on top of a stack of modules). The slight gravity pressure reduces the under pressure the pump requires to draw solvent from the solvent bottle. 270 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Additional Information If You Need Operational Hints Pump Head Assembly In February 1992, the pump head assembly was improved. The seal, the pump chamber housing and the seal keeper have been changed. All together the changes will assure a higher lifetime for the pump seal. Seal A dedicated seal was designed for the 1050 Pumps. Compared to the old seal used in 1050 and in the 1090 the seal is the same material and color, but slightly different in appearance. Nevertheless the seals are fully backward compatible. They should be used in all existing 1050 pumps. Lifetime should be expected the same as always. The wear retainer is still required. Pump Chamber Housing and Seal Keeper A groove has been added to the seal surface of the pump chamber and a cutting edge was added to the seal keeper. These both changes ensure a better compression of the new seal resulting in a higher lifetime. Part numbers of the two parts were not changed because of there compatibility. PDC Board When exchanging the metering drive assembly 01018-69100 in a pump with PDC Board revision A installed (see “Product History” on page 257), the voltage regulators U78 and U79 on the board have to be replaced. Parts are included in the exchange metering drive. PDC Board revision B and greater and the PDC2 Board do not have the new type voltage regulator already installed. A short in the active inlet valve cable (for example cable squeezed between pump head and metering drive) will generate excessive current on the components of the PDC board. This overcurrent will at least damage (unsolder) one resistor on the board. The fuse added to the CON board (introduction approximately January 1992) will prevent damage of the PDC board. PDC2 Board In a standardization (board will also be used in other APG products) and cost reduction program part of the circuit was implemented in ASIC (Application Specific Integrated Circuit) which allowed a reduction in board size. A stainless steel plate and the cover plate assure compatibility to the 1050 board. Service Handbook for 1050 Series of HPLC Modules - 11/2001 271 Pumps: Additional Information If You Need Operational Hints HRQ Board Originally the fuse F16 on the HRQ board was a 500 mA type. Evaluation of returned defective exchange boards showed that the fuse was blown in most of the cases. The fuse was to weak and could be blown without circuit failure. Therefore the fuse was changed to a 1 A type. GVD Board At introduction of the 1050 Pumps the Gradient Valve Driver (GVD) board controlled the multi channel gradient valve (MCGV). During the design phase of the column heater option it was decided that the control of the heater should be also done via the same board. Therefore the GVD was replaced by the HRQ board for control of column heater and gradient valve (see “Product History” on page 257). Wear Retainer The abrasion of the seal is a very well known fact. The wear retainer is a device which keeps the departed particles around the seal instead of allowing to move immediately into the flow path. The retainer consist of a small porous Teflon disc placed directly in front of the seal. When installed the retainer disc deflects and with the piston diameter slightly bigger than the one of the Teflon disc a recess for the seal material is build. With the operation time the plunger will widen the diameter of the disc allowing part of the particles to move into the flow system. Therefore the wear retainer should always be changed together with the seal. The high pressure filter in the purge valve will collect all this materials without problem. When changing the seals also the high pressure filter should be changed too. 272 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Additional Information If You Need Operational Hints Outlet Ball Valve The outlet ball valve is a cartridge type and does not need any maintenance. It is not spring loaded and therefore uses gravity and the back pressure for closing. To increase the reliability of this type of valve two ceramic seat/ ball packages are used. The valve is less sensitive to contaminations and does not require a sieve assembly in front. The cap in front of the valve holds a gold seal for proper tightening. If the valve fails it is probably contaminated. Cleaning can be done either in a sonic bath or by flushing using degreaser spray in flow direction. Disassembling will damage the valve. The outlet ball valve should only be tightened at the holding screw and not at the cartridge itself. Under worst case conditions this could damage the cartridge generating leaks at the seat/ball packages. Flow Test Method The flow test method should be always started with the remote mode in LOCAL. If set to GLOBAL the test method can be inhibited when a manual injection valve in inject position is connected via the remote connector. If the remote mode is set to HPSYSTEM the flow test will not be started at all, because of the start request which is send out instead of a start. Method loading If a method will be loaded while pumping, the pump might be switched off when there is a lower pressure limit set in the new method. Flow Gradients Timetables containing flow gradients with a starting point of 0 ml/min will not be executed. Gradient parameter changes will always be executed at the culmination point of the first piston. With a flow set to zero, this point will never be reached. Manual Injection Valve Starting a 3390A or 3394A from the remote start of the manual injector requires a slight modification of the injection sensor. 3390/94 integrators need a dynamic signal which the manual injector can provide only if position sensor is installed into an upright position. Service Handbook for 1050 Series of HPLC Modules - 11/2001 273 Pumps: Additional Information If You Need Operational Hints Metering Drive Repairs Evaluation of defective metering drives 01018-69100 showed that the wiper in the spindle housing was broken or bent. The wiper defines the position of the spindles to each other. Discussions with CE’s revealed that some people try to check out the metering drive without the pump head installed, especially when troubleshooting E27 (max motor drive power exceeded) problems. When the pump head is removed and the pump is initialized the spindle movement is stopped by the wiper. The pump displays the message pumphead missing. This is generally no problem for the mechanical system. The following problems may occur when operating from this point on. ❏ The pump is turned on again without reinstalling the pump head. Under this condition the pump will start with normal operation. The wiper position is used as reference point. The movement of the spindle is always stopped by hitting the wiper. This operation condition may damage the wiper or misalign the spindles. ❏ The pump head is reinstalled without initializing the pump. The pump still uses the previous determined position as the reference values for the pump. So when started the piston may run with full flow speed into the mechanical stop. This can crack the pistons. This problems can be avoided by: ❏ NOT running the pump without pump head installed (also not for test reasons). ❏ Always do a pump initialization when the pump head is re-installed. 274 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Pumps: Additional Information If You Need Operational Hints Troubleshooting E27 Errors (Max Motor Drive Power Exceeded) The E27 can have two reasons - a problem in the metering drive and also a blocked outlet ball valve. ❏ Blocked Outlet Ball Valve. It is possible that the valve is blocked (for example the pin on the ball canted). In such a case the first piston cannot deliver anything onto the high pressure side. The pressure in the first chamber rises to values far above 400 bar. This pressure in the first chamber cannot be detected by the pressure damper as it is located behind the outlet ball valve. The pump motor working against a too high pressure will exceed the maximum allowed drive power and gives error E27. This can also be an intermittent problem. Troubleshooting Procedure: ❏ Remove outlet ball valve and let the pump run without the valve. ❏ Replace the outlet ball valve and pump at high back pressure (restriction). Error E27 under this condition verifies metering drive problems. No error messages identify faulty outlet ball valves. ❏ Problem with Metering Drive. Possible problems on the metering drive are defective bearings defective motors or misalignment of the wipers. Troubleshooting Procedure ❏ Proceed in the same way as described before. Intermittent motor problems might be identified. ❏ Remove pump head and press down spindle by hand. This should be possible without too much resistance. High resistance indicates a bearing defect. ❏ Remove metering covers and check for broken or loose wipers. Service Handbook for 1050 Series of HPLC Modules - 11/2001 275 Pumps: Additional Information If You Need Operational Hints Piston with Conical Holder Reports from the field and evaluation of returned parts showed that the spring in the piston housing can scratch at the piston holder and may generate a squeaking noise. This will not lead to a malfunction of the pump but the noise has lead to customer complaints. The piston holder was changed and now has a conical shape. The spring should no longer scratch at the piston holder. Ghost Leak messages If the pump shows intermittent leak messages without any solvent in the leak tray you should check the following two points. • Make sure that the leak sensor is not in close proximity of the plastic funnel. This can cool down the sensor to the trigger level resulting in ghost error messages. • Check the revision of the CMP board. CMP boards with revision E and higher do have a improved leak sensor circuit installed. CMP boards with revision D or below can be modified by soldering two 100nF capacitors (0160-6623 or 0160-0576) between pin 12 and 11 and pin 12 and 9 of U45. U45 is the sixth IC in the bottom row of the board (main connector on right side). There are two fourteen pin IC beside each other. U45 is the right one. PANIC Errors Intermittent PANIC errors are mostly generated by spikes (disturbances) on the bus lines. A dynamic bus termination has been added to the FIM board to suppress the spikes and to reduce the possibility of this failure mode. All firmware boards with revision C and higher do have the dynamic bus termination installed (RC-network instead of a R-network). In case of intermittent PANIC errors replace FIM boards (rev A or B) with the current version. 276 Service Handbook for 1050 Series of HPLC Modules - 11/2001 In This Book This manual contains technical information about the Agilent 1050 liquid chromatographs. This manual is available as electronic version (Adobe Acrobat Reader file) only. 1050 Series of HPLC Modules Service Handbook Sampler (79852A/B) Copyright Agilent Technologies 2001 All rights reserved. Reproduction, adaption, or translation without prior written permission is prohibited, except as allowed under the copyright laws. Part No. NONE 11/2001 Printed in Germany Warranty IMPORTANT NOTE The information contained in this document is subject to change without notice. This version of the 1050 service manual includes all sections from the 01050-90102 edition 4 (1995) and G1306-90102 edition 2 (May 1994). It merges both sections, the MWD and the DAD. Agilent Technologies makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties or merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Agilent Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn Germany The series I opticals information (79854A MWD) information has been removed (product went out of support during 2000). Part numbers have been updated as of 11/2001. Contact your local Agilent support office in case of part number issues or upgrades. The latest version of this manual is available as Adobe Acrobat Reader (PDF) version only and can be downloaded from the Agilent Technolgies web page www.agilent.com. 11 11 Sampler: General Information This chapter provides general information about the 1050 Autosampler Sampler: General Information This chapter gives general information on • about this autosampler • repair policy • product structure • capillaries • specifications About this Manual This manual provides service information about the 1050 Autosamplers. The following sections give the detailed descriptions of all electronic and mechanical assemblies. You will find illustrated part-breakdowns interconnection tables connector configurations as well as all necessary replacement procedures in this manual. Detailed diagnostic procedures using firmware resident test methods and error messages are also given in this manual. About the Autosampler The 1050 Autosampler module houses the mechanical devices and the electronic circuitry for control of the various functions of the injection system. The module is controlled through the user interface through which the operator defines his requirements (vial number, injection volume and so on) and which provides the required information. 282 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: General Information Repair Policy Repair Policy The 1050 Autosampler is designed that all components are easy accessible. Customers are able to repair certain parts of the 1050 Autosampler, see Operator’s Handbook. For details on repair policy refer to “Repair Policy” on page 38. Product Structure The 1050 Series of HPLC modules are available in two versions. In the standard version most of the parts in the flow path are stainless steel. In the 1050 Ti Series the flow path of the autosampler consists solely of corrosion resistant materials such, as titanium, tantalum, quartz, sapphire, ruby and fluorocarbon polymers. It is recommended for use with mobile phases containing high salt concentrations, extreme pH solutions and other agressive mobile phases. Autosampler 79855A Ti - Autosampler 79855B Service Handbook for 1050 Series of HPLC Modules - 11/2001 283 Sampler: General Information Capillaries Capillaries In the 1050 Series all capillary shipped with the modules will have a plastic colour coating for identification in terms of material and internal diameter. Table 67 Capillary Color Code color Internal Diameter blue 0.25 mm green 0.17 mm red 0.12 mm white N OT E Material tantalum The capillaries for the 1050 Series will have only one color coating for the internal diameter. The capillaries for the 1050 Ti Series have two color coatings. One for identifying the material, covering the main part of the capillary, and a small one for the internal diameter. For the 1050 Ti Series the fittings are always titanium with a titanium nitrite coating and the front and back ferrules are gold plated. 284 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: General Information Specifications Specifications Table 68 Specifications of 1050 Autosampler Injection Range Programmable from 0.1 to 100 µl in 0.1 µl increments without hardware change required. Up to 1.8 ml with larger injection valve capillary. Replicate Injections 1-99 from one vial. Precision Typically <0.5% RSD of peak areas from 5-100 µl and <1% from 2-5 µl Minimum Sample Volume 1 µl can be sampled from 5 µl in 100 µl micro vial or 10 µl in 300 µl micro vial. Carryover <0.1% typically Wash Cycle None required, sample path flushed continuously with mobile phase during normal operation. Sample Viscosity Range 0.2 - 50 cp Sample Capacity 21 or 34 in standard trays, with additional 100 in external tray (less two positions for access). Random Vial Access <4 seconds from standard tray. Injection Cycle Time 20 seconds typically, depending on injection volume and drawing speed. Recommended pH Range 2.3 to 9.5 standard; 1.0 to 12.5 optional (TEFZEL™ replaces VESPEL™ rotor). Solvent with pH below 2.3 should not contain acids which attack stainless steel. Ti-Series pH 1 to 14. Control Integrated keyboard with function keys; parameter editing possible during run; keyboard lock. Optional control by PC or 3396 Series II integrator. Method Parameters Injection volume, draw offset, sample draw/eject speed, 2 external contacts, stop time, post time, injector program. Service Handbook for 1050 Series of HPLC Modules - 11/2001 285 Sampler: General Information Specifications Table 68 Specifications of 1050 Autosampler Methods Battery-backed storage of up to 10 methods. Automatic startup and shutdown methods. Editing of stored methods possible during run. Sequence Parameters Up to 10 parameter sets, each with keyboard setup of: first- and last sample vial, # of injections per sample vial, first- and last calibration vial, # of injections per calibration vial, re-calibration frequency and injection method. Editing of stored parameter sets possible during run. Communications Inputs: start request. Outputs: BCD for bottle number; start; two external relay contacts (one 24 V relay, one 30 V (AC/DC) contact closure, both 0.25A). In- and Outputs: stop, ready, shut, down. Optional interface for GPIB and RS-232C. Safety Aids Extensive diagnostics, error detection and display via front-panel LED’s and status logbook. User-definable shutdown method activated in case of error. Leak detection, safe leak handling, leak output signal to shutdown pump. Low voltages in major maintenance areas. Environment 4°C to 55°C (constant temperature) with <95% humidity (non-condensing) 100-Sample Tray Temperature Control 1°C to 60°C using external circulating bath with thermostat. Power Requirements Line voltage: 100-120 or 220-240 VAC ±10% Line frequency: 48-66 Hz Power consumption: 120 VA max. Autosampler Dimensions Height: 208 mm (8.2 in) Width: 325 mm (12.8 in) Depth: 560 mm (22.0 in) Weight: 16 kg (35 lb) 286 Service Handbook for 1050 Series of HPLC Modules - 11/2001 12 12 Sampler: Hardware Information This chapter provides hardware information about the 1050 Autosampler Sampler: Hardware Information This chapter gives general and technical information about the hardware components of the 1050 Autosampler. • Overview about the Autosampler • Autosampler hardware • Sampling Unit ❏ Metering Drive ❏ Analytical Head Assembly ❏ High Pressure Switching Valve ❏ Pneumatic Assembly • Additional 100 vial capacity 288 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Hardware Information Overview Overview The 79855A/B Autosampler is a fully programmable module and is controlled via the user interface. The operator sets the parameters at the user interface which provides also the required analytical information. The processor controlled electronic drives the mechanic of the 79855A/B Autosampler consisting of sampling unit metering device and high pressure valve unit. The pump delivers flow to a six port high pressure valve unit in which a sampling unit and a metering device take the place of a sample loop. In normal mode the needle of the sampling unit is held firm in its seat forming a leak free seal. The valve unit directs the solvent through the metering device and the sampling unit to the column. During injection the flow is bypassed and the metering device loads the sample. Needle and metering device are always flushed and ready for the next injection. Service Handbook for 1050 Series of HPLC Modules - 11/2001 289 Sampler: Hardware Information Solvent Flow Path Solvent Flow Path Solvent coming from the pump (capillary #1) enters via port 1 of the switching valve the autosampler. In normal mode (switching valve in main pass) the flow is guided from port 2 to the analytical head (capillary #2) and from there via the loop capillary (#3) and the fitting (#4) to the needle (#5). The needle is pressed into the seat and via the seat capillary #6 the flow streams back to port 5 of the switching valve. The seat capillary can be extended for injection volumes above 100 µl (multiple injections). From port 6 of the switching valve the solvent will be connected to the column (capillary #7). During the injection cycle (switching valve in bypass) ports 1 and 6 are connected and flow is directly connected to the column. The metering device displaces its volume into the waste (capillary #8) before drawing the injection volume form the vial. Figure 106 Solvent Flow Path 290 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Hardware Information How Does The Autosampler Work? How Does The Autosampler Work? The processor controls the injection sequence. To avoid malfunctions the 1050 Autosampler will perform a mechanical reset after initial turn-on of the module. It can also be reset using the {{CONTROL RESET}} instruction of the user interface. First step of the injection sequence is activating the pneumatic valve unit so that the air pressure can change the position of the high pressure switching valve (see step 1 on page 292). The flow is bypassed and sampling unit and metering device are without pressure. The stepper motor of the metering device is activated moving the piston to its home position displacing its volume into waste. Next the electrically driven sampling unit lifts the needle and moves the sampling tray with a programmed vial under the needle (see step 2 on page 292). If the additional 100 sample tray (18596L/M) is installed the arm of this tray moves the vial into the transfer position of the 21 sample tray (vial 16). The sampling unit lowers the needle into the vial and the programmed injection volume is then drawn up into the sampling unit by the metering device. The needle is raised the tray is moved back to home position and the needle is reseat. The valve unit returns to its normal position reconnecting the needle loop to the flow system (see step 3 on page 292). All of the sample is pumped out of the 1050 Autosampler onto the column. Sampling unit and metering device are always in the main flow path (normal mode) and therefore an extra flushing procedure is not necessary. In case of air in the system (metering device) increase flow (for example 5 ml) or use appropriate solvent (for example isopropanol). Service Handbook for 1050 Series of HPLC Modules - 11/2001 291 Sampler: Hardware Information How Does The Autosampler Work? 1 Injection Sequence I 2 Injection Sequence II 3 Injection Sequence III 292 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Hardware Information The Injection Sequence The Injection Sequence The injection sequence is stored in controller memory. For each step of the sequence a time for execution is assumed. If execution takes too long (time-out) or fails, it will result in an aborted injection and an error message. Each single step of the sequence can be executed solely when the system is brought into the test functions. 1 Switch Valve Unit to bypass flow. 2 Initialize Metering Device. # Includes step 1 to 5 of 18596L/M sample tray if installed and selected. 3 Raise needle. 4 Move vial underneath needle. 5 Lower needle into vial. 6 Draw sample up from sample vial. 7 Raise needle out of vial. 8 Move vial back to home position. 9 Lower needle onto seat. 10 Switch Valve Unit to flow through sample loop. # Executes steps 6 to 9 of 18596L/M sample tray if installed and selected. N OT E Steps 1 through 5 can be aborted. Service Handbook for 1050 Series of HPLC Modules - 11/2001 293 Sampler: Hardware Information What happens when the 18596L/M Sample Tray is connected? What happens when the 18596L/M Sample Tray is connected? If the optional 18596L/M sample tray is connected to the autosampler, the additional steps of the 100 sample tray will be incorporated into the injection sequence. The 100 sample tray arm will move each selected vial into the transfer position 16 of the 21 sample tray. After the injection, the 100 tray arm moves the vial back to the original position in the 100 vial tray. 1 Initialize 100 vial tray. 2 Move to selected vial position. 3 Pick up vial. 4 Move to 21 sample tray. 5 Insert vial into position 16 of 21 sample tray. 6 Remove vial from 21 sample tray. 7 Move arm to vial position. 8 Insert vial into 100 vial tray. 9 Move the 100 tray arm to home position. 294 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Hardware Information Overview of the Electronics Overview of the Electronics Figure 107 shows the block diagram of the 1050 Autosampler including all currently available options. The Common Main Processor (CMP) controls all functions of the module. The firmware board (FIM) containing the EPROM’s with the sampler specific firmware is attached to the VMD board. Therefore the processor board (CMP) remains identical for all modules. The Max Tray Drive (MTD) controls the 18596L/M 100 sample tray when connected to the autosampler. This expands the vial range from 21 vials to a total of 119 vials. Two vial positions in the 21 vial tray are needed for access from the 100 vial tray. The rotor reader option can be connected to the 18596L/M tray. Electronic control is done from the rotor reader board which is attached to the MTD board. The communication interface board (CIB) provides an GPIB and RS232C interface. With the CIB installed the autosampler can be controlled via the LC ChemStation or via the 3396 Series II integrator. Service Handbook for 1050 Series of HPLC Modules - 11/2001 295 Sampler: Hardware Information Overview of the Electronics Figure 107 Block Diagram 1050 Autosampler 296 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Hardware Information Sampling Unit Sampling Unit Repair Level: Component (see Parts ID) Table 69 Part Numbers Sampling Unit Item Part Number Sampling Unit 01078-60001 Ti - Sampling Unit 01079-60001 The Sampling Unit comprises two functions, control of needle movement and positioning the respective vial under the needle. The sampling unit is controlled by the needle mini tray drive board (NMD). The stepper motor for the needle movement is connected to a lead screw which moves the needle arm with the needle up and down. Lightswitches at the needle arm check for upper and lower limit of the needle and also check the presence of a vial during the injection cycle. The second stepper motor drives the coupler which holds the sample tray. The home position of the tray is determined when a little magnet in the tray is located directly above the home sensor. Standard sample tray with 21 vials or micro tray with 34 vials are identified by the polarity of the tray magnet (north pole for standard tray and south pole for the micro tray). A quadrature encoder on the coupler shaft allows accurate positioning of the tray. Service Handbook for 1050 Series of HPLC Modules - 11/2001 297 Sampler: Hardware Information Sampling Unit Table 70 Technical Data Sampling Unit Number of spindle motor steps between upper and lower limit 5867 steps (44 mm) Number of spindle motor steps between upper limit and needle in vial position 5334 steps (40 mm) Needle speed 20 mm/sec Spindle 200 steps (1.5 mm)/revolution Number of encoder wheel slits 500 Resolution of the tray 2000 steps/revolution Reproducibility of tray position ±1 mm Tray speed 2.3 seconds/revolution Sealing Force 50-55 N Ti Series Materials in contact with solvent: Figure 108 tantalum, titanium, Peek, gold Sampling Unit 298 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Hardware Information Metering Drive Metering Drive Repair Level: Assembly or component level for given parts (see Parts ID) Table 71 Part Numbers Metering Drive Item Part Number Metering Drive 01078-60002 The Metering Drive is responsible for drawing the sample into the sample loop. The stepper motor controlled by the Valve Metering Drive Board (VMD) drives the spindle via a belt. The circular movement of the spindle is transformed in a linear movement for the piston via a bronze nut. A light sensor determines the home position of the piston. Table 72 Figure 109 Technical Data Metering Drive Resolution of mechanical system 7 nl/step of motor Number of steps between extension limits 15000 Metering Drive Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 299 Sampler: Hardware Information Analytical Head Assembly Analytical Head Assembly Repair Level: Component (see Parts ID) Table 73 Part Numbers Metering Drive Item Part Number Analytical Head assembly 01078-60003 Ti - Analytical Head assembly 01079-60003 The sapphire piston moves up or down the spindle on a bronze nut. The built in spring prevents clearance affecting drawing accuracy. Piston movement in the analytical head is guided by a sapphire ring. On the backward stroke the piston draws sample from the vial. Table 74 Technical Data Analytical Head Maximum stroke 100 µl Ti Series Materials in contact with solvent Figure 110 Filled Teflon, sapphire, titanium Analytical Head Assembly 300 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Hardware Information High Pressure Switching Valve High Pressure Switching Valve Repair Level: either Exchange Assembly or component level for given parts (see Parts ID) Table 75 Part Numbers Metering Drive Item Part Number Exchange High Pressure Switching Valve 01078-60004 01078-69004 Ti - High Pressure Switching Valve 01079-60004 01079-69004 The High Pressure Switching Valve bypasses the flow direct to the column during the injection cycle. The valve is air driven. The switching positions of the valve are sensed with a light switch that provides a status signal to the Valve Metering Drive (VMD) indicating proper execution of any movement. Table 76 Technical Data High Pressure Switching Valve Ti Series Materials in contact with solvent Figure 111 Tefzel, titanium, ceramic High Pressure Switching Valve Service Handbook for 1050 Series of HPLC Modules - 11/2001 301 Sampler: Hardware Information Pneumatic Assembly Pneumatic Assembly Repair Level: Component (see Parts ID) Table 77 Part Numbers Pneumatic Assembly Item Part Number Pneumatic Assembly 01078-66101 Air supply is connected from the rear of the module to a self latching solenoid valve. Pressure is sensed for an under pressure condition (<5 bar) with a sensor that provides an electrical status signal. Air pressure is applied to the SUP connector of the valve. In normal position pressure is connected to connector CYL1.When the solenoid is activated by a pulse, the air stream is directed to outlet CYL2 and the air pressure moves the 6 port valve and forces it to stay there. Air pressure is applied to the SUP connector of the valve. In normal position pressure is switched to connector CYL1 and when the valve is switched it moves to CYL2. Both exhaust outlets (EXH1/EXH2) are connected together at the rear of the module. The air leaves through a filter to reduce the noise during the switching. Electrical control of the valve is from the Valve Metering Drive (VMD). Figure 112 Valve Connections 302 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Hardware Information Pneumatic Assembly For test reasons the actuator air solenoid may be switched manually. Actuator Air Solenoids Manual air actuation is done in the following way: Table 78 Figure 113 Switching of Solenoids Screw A Screw B Cyl #1 Cyl #2 Comment 0 0 SUP EXH Relaxed Position 1 0 SUP EXH 0 0 SUP EXH 0 1 EXH SUP 0 0 EXH SUP Solenoid ready for next switch Solenoid ready for next switch Pneumatic Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 303 Sampler: Hardware Information Additional 100 Sample Capacity Additional 100 Sample Capacity Repair Level: Component This option for the autosampler comprises the max tray drive board assembly (MTD), the tray support and the foot support. A new firmware might be required when updating existing instruments. With these parts it is possible to adapt the unmodified 18596A/B GC tray to the 79855A Autosampler (See also Updating to an additional 100 vial tray). The 100 vial tray has to be ordered separately. N OT E The 18596A/B tray get a different order suffix when ordered for an 1050 Autosampler. Reason are the different accessories (for example manuals and so) when ordered for an LC or GC. Table 79 100 Vial Tray GC LC 18596A 18596L 18596B 18596M For access of the additional vials the firmware adds 100 to each tray position so that the 100 sample tray holds the positions 101 to 200. The arm of the 100 sample tray moves the selected bottle into position 16 of the 21 sample tray. Position 15 has to be empty for the undisturbed movement of the tray arm. After the injection the vial is placed back into its original position in the large tray. The remaining vial range of the 21 sample tray (1 to 14 and 17 to 21) is fully accessible. The firmware automatically skips vial 15 and 16. N OT E Service Information about the 18696A/B can be obtained from the 7673 Service Manual for the A tray and for the B tray. 304 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Hardware Information Additional 100 Sample Capacity Figure 114 Additional Tray Option Service Handbook for 1050 Series of HPLC Modules - 11/2001 305 Sampler: Hardware Information Additional 100 Sample Capacity 306 Service Handbook for 1050 Series of HPLC Modules - 11/2001 13 13 Sampler: Electronic Information This chapter provides electronic information about the 1050 Autosampler Sampler: Electronic Information This chapter gives information about the electronic of the 1050 autosampler: • Overview • Max Tray Drive Board (MTD) • Needle Mini Tray Drive Board (NMD) • Valve Metering Drive Board (VMD) • Firmware Board (FIM) • Autosampler Motherboard (ALM) 308 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Electronic Information Overview Overview All electronic boards (except the FIP, behind the keyboard) are located in the rear part of the module and they are connected to the Motherboard (ALM). Excess to the boards is from the rear of the instrument. Slot numbers (for example in the status display) are counted from left to right. The Power Supply (DPS-B) is located in slot 1 and the common main processor is located in slot 7. The rear of the autosampler is shown in Figure 115 on page 310. In the Autosampler the following electronic assemblies are available: Table 80 Electronic Boards Description Part Number Exchange Power Supply (DPS-B) 5061-3374 01050-69374 Common Main Processor (CMP) 01050-69380 01050-69580 01078-66503 01078-69503 ## Max Tray Drive Assembly (18596B/M) (MTD) 01078-66513 01078-69513 # Max Tray Drive Assembly (18596A/L) (MTD) # Rotor Reader Drive Assembly (G1926A) (RRC) 01078-66507 # Valve Metering Drive (VMD) 01078-66501 01078-69501 Needle Mini Tray Drive (NMD) 01078-66502 01078-69502 Firmware Board (SFW) 01018-66506 Motherboard (ALM) 01078-66504 Display Interface Board (FIP) 5061-3376 Communication Interface (CIB) 5061-2482 Optional board ## Optional board, attached to the MTD board (not described in this manual) Service Handbook for 1050 Series of HPLC Modules - 11/2001 309 Sampler: Electronic Information Overview N OT E For information about Power Supply, Common Processor and Fluorescent Interface refer to chapter 1050 Common Information. Figure 115 Rear of 1050 Autosampler N OT E The MTD board is optional. 310 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Electronic Information Overview Figure 116 Block Diagram 1050 Autosampler Service Handbook for 1050 Series of HPLC Modules - 11/2001 311 Sampler: Electronic Information Max Tray Drive Board (MTD) Max Tray Drive Board (MTD) Repair Level: Board Table 81 N OT E Part Numbers for MTD Board Item Part Number Exchange MTD Board 18596M 01078-66513 01078-69513 MTD Board 18596L 01078-66503 01078-69503 RRC Board for both versions 01078-66507 The RRC board will be attached to the MTD board when Rotor Reader Option (G1926A) for the 100 vial tray is installed. The function of the board is to control the 18596L/M sample tray and to provide the electrical interface to the common main processor (CMP). The 18596L/M is part of the 7673A product family. I/O Control The I/O control circuit enables the common main processor (CMP) and the maxi tray drive (MTD) to exchange data. This is done via a bidirectional I/O buffer. A board identification (a resistor network) allows the processor to identify the board and to address. Sensor Status Via the sensors interface circuit the sensor status is transferred to the sensor status latch. The sensor status latch transfers the information via the common bus to the CMP. 312 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Electronic Information Max Tray Drive Board (MTD) Data Conversion While the common main processor bus has a parallel data structure the Main Processor Unit (MPU) uses a serial data bus. The data conversion section performs the parallel to serial and serial to parallel conversion for the different bus structures. Figure 117 Block Diagram MTD Board Clock The clock circuit provides all necessary frequencies for the main processor unit (MPU) and the data conversion section. It uses a 4.9152 MHz clock generator. Service Handbook for 1050 Series of HPLC Modules - 11/2001 313 Sampler: Electronic Information Max Tray Drive Board (MTD) Main Processor Unit (MPU) The MPU is the heart of the MTD board and controls all the functions of the 18596L sample tray. All the necessary memory needed to run the 100 tray resides inside the MPU chip. The MPU chip provides all the signals for the motor drivers and sends a tray fault signal out in case of malfunctions. To control all the steps of the tray the MPU reads the sensor status from the sensor interface. Reset and Watchdog This circuit checks for proper operation of the Main Processor Unit (MPU). In case of malfunctions (for example timing problems and so on), the reset and watchdog resets the system preventing any damage of the 18956L tray. The System OK Signal (SOK) from the Common Main Processor (CMP) is also fed into the reset and watchdog block. In case of 79855A processor problems or problems which influence the SOK status, the reset and watchdog will also reset the MTD board. Motor Drivers Three motors control all the movements of the 18596L 100 sample tray. The radial arm drives (R-Motor) and the gripper drives (Z-Motor) are similar. To keep the position of the arm or the gripper mechanism when not turning the motors are powered down to maintain a standby torque. The angular driver (Theta-Motor) provides a constant standby current in chopper mode and normal on/off switching of the motor windings at standard speed. Sensor Interface Three position sensors are located in the tray to provide feedback as to the position of the tray arm. An additional sensor in the gripper on the arm to indicates the presence of a bottle. The bottle sensor is simply a micro switch which provides a short ground when the bottle is present. The two position sensors that are used to sense the home positions for radial (R) axis and gripper (Z) axis are hall sensors that provide a logic low output when they encounter a suitable magnetic field. Small permanent magnets are placed in the appropriate positions in the tray. The angular (Theta) axis position sensor is an optical photo diode transistor pair. The photo diode is turned on only when the motor is being actuated. The interlock is a sense line which identifies whether the sample tray (cable) is installed or not. 314 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Electronic Information Max Tray Drive Board (MTD) Figure 118 Board Layout MTD Service Handbook for 1050 Series of HPLC Modules - 11/2001 315 Sampler: Electronic Information Needle Mini Tray Drive Board (NMD) Needle Mini Tray Drive Board (NMD) Repair Level: Board, Capacitor Table 82 Part Numbers for NMD Board Item Part Number Exchange NMD Board 01078-66502 01078-69502 Capacitor 100 pF (between pin 5 and 7 of U26) 0160-4801 The main function of the NMD board is the control of needle motor and tray motor. Capacitor 100pF Firmware revision 4.0 and above require a modification of the NMD board. Otherwise incorrect positioning of the 21 or 34 vial tray may occur. The 100 pF capacitor soldered between pin 5 and 7 of U26 solves the problem. Instruments with serial number prefix 3117 G ..... or 3121 A ..... do have this capacitor. I/O Control The I/O control circuit enables the common main processor and the needle mini tray drive (NMD) to exchange data. This is done via a bidirectional I/O buffer. A board identification circuit allows the processor to identify the board and to address it. BCD Output The circuit codes the bottle number into BCD and provides the signal to the connector on the back of the NMD board. The BCD code is implemented in positive true logic. Firmware REV 2.0 and above allow configuration of the output for either 2 digit BCD coded or 8 bit binary (HEX) coded information. 316 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Electronic Information Needle Mini Tray Drive Board (NMD) Figure 119 Block Diagram NMD Board Service Handbook for 1050 Series of HPLC Modules - 11/2001 317 Sampler: Electronic Information Needle Mini Tray Drive Board (NMD) Sensor Status The hall sensor, the bottle sensor and the needle sensor are connected to this circuit block. The hall sensor checks the presence of the sample tray and is used to set the home position. The bottle sensor checks for the presence of a bottle during injection cycle. The needle sensor checks upper and lower position of the needle. The status information from the sensors are transferred directly to the processor. Control Logic The control logic provides the motor parameters to the motor driver. The parameters are the direction, resolution and current for the motors. The control logic starts the timer and stops it under two conditions. In case a light sensor detects the home position or the number of steps of the motor have been elapsed, the timer will be stopped. To increase the life time of the sensors the control logic activates the light sensors only during the injection cycle and switches it off afterwards. Timer The timer chip of the timer circuit consist of three independent timer/counter stages from which only two are used. One timer generates the speed (step frequency) of needle and sample tray motor. The second timer defines the number of steps the motor has to perform to reach its selected destination (needle position). Motor Driver The motor driver delivers the power to the two motors. A bipolar phase controller allows a high torque at high frequency for the movement. Quadrature Decoder The quadrature encoder on the tray coupler senses the movement of the sample tray. The derived signals contain information of the direction and the actual position of the tray motor. The decoder reads the signals and transfers the information to the processor. 318 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Electronic Information Needle Mini Tray Drive Board (NMD) Figure 120 Board Layout NMD Service Handbook for 1050 Series of HPLC Modules - 11/2001 319 Sampler: Electronic Information Valve Metering Drive Board (VMD) Valve Metering Drive Board (VMD) Repair Level: Board, Fuse Table 83 Part Numbers for NMD Board Item Part Number Exchange Valve Metering Drive (VMD) 01078-66501 01078-69501 Fuse F12, F14 250 mA 2110-0004 The main functions of the board is to control the Metering Drive and the High Pressure Switching Valve. In addition the VMD board holds also the firmware for the common main processor (CMP).The firmware is attached to the VMD board but has no functional connection to the board. I/O Control The I/O control circuit enables the common main processor and the Valve Metering Drive (VMD) to communicate data. This is done via a bidirectional I/O buffer. A board identification circuit allows the processor to identify the board and to address it. Control Logic The control logic provides the motor parameters to the motor driver circuit. The parameters are the direction, resolution and current for the metering drive motor. The control logic starts the timer. It stops it in case the home position light switch is activated or the motor steps have been elapsed. To increase the life time of the sensors the control logic activates the light sensors only during the injection cycle and switches it off afterwards. The pneumatic valve will be switched via the valve driver circuit to change the position of the high pressure switching valve. 320 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Electronic Information Valve Metering Drive Board (VMD) Figure 121 Block Diagram VMD Board Service Handbook for 1050 Series of HPLC Modules - 11/2001 321 Sampler: Electronic Information Valve Metering Drive Board (VMD) Relay Contact Control Two relay contacts are controlled. When activated, contact 1 provides fused (250 mA) +24 V, while contact 2 provides a fused (250 mA) 30 V maximum (AC/DC) rated contact closure. For more information about the relay contacts see “External Contacts” on page 56 in the chapter 1050 Common Information. Timer The timer chip of the timer circuit consist of three independent timer/counter stages from which only two are used. One timer generates the speed (step frequency) of the metering motor. The second timer defines the number of steps the motor has to perform to reach its selected destination (volume). Motor Driver The motor driver delivers the power to the motor. A bipolar phase driver allows a high torque for the movement. Sensor Status The metering home sensor the valve position sensor and the air pressure switch are connected to the sensor status circuit. The home position sensor checks whether the piston of the metering unit is in the maximum front position or not. The valve position sensor checks the switching of the bypass valve. The air pressure switch senses low air pressure in the system and inhibits further injections. The metering motion status signal gives the information whether the metering drive motor is running or not. The signal is derived from the timer circuit. The switch (S28) is not used so far and is reserved for future use. 322 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Electronic Information Valve Metering Drive Board (VMD) Figure 122 Board Layout VMD Service Handbook for 1050 Series of HPLC Modules - 11/2001 323 Sampler: Electronic Information Firmware Board (FIM) Firmware Board (FIM) Repair Level: Board Table 84 Part Numbers for FIM Board Item Part Number Firmware Board (New) 01078-66506 The FIM board is a piggy back board, placed on VMD board (“personality module”). • The programmed FIM contains the firmware of the 1050 Autosampler. • The board is designed for on board programming. • The FIM contains 128K x 8bit EPROMs. • All inputs/outputs are pulled down for electrostatic discharge protection. Figure 123 Layout of FIM Board 324 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Electronic Information Autosampler Motherboard (ALM) Autosampler Motherboard (ALM) Repair Level: Board Table 85 Part Numbers for ALM Board Item Part Number ALM Board 01078-66504 The motherboard contains all connectors for the boards and the assemblies in the front part, like sampling unit, metering drive, high pressure switching valve, pneumatic valve and keyboard. Figure 124 on page 326 shows the location of all connectors. A mechanical Injection Counter displays the actual number of injections counted by switching valve transitions. Service Handbook for 1050 Series of HPLC Modules - 11/2001 325 Sampler: Electronic Information Autosampler Motherboard (ALM) Figure 124 Layout of Autosampler Motherboard Table 86 ALM Connectors J1 - Power Supply J9 - DGND J17 - Leak Sensor J2 - TAR Board J10 - Bottle Sensor J18 - Home Sensor J3 - VMD/FIM Board J11 - future option J19 - Metering Motor J4 - NMD Board J12 - Needle Motor J20 - Valve Position J5 - Not used J13 - Tray Motor J21 - Low Pressure Switch J6 - Not used J14 - Shaft Encoder J22 - Pneumatic Solenoid Valve J7 - CMP J15 - Hall Sensor J8 - FIP Keyboard J16 - Needle Sensor Figure 125 on page 327 to Figure 127 on page 329 show the main signals and voltages of the various boards and connectors. 326 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Electronic Information Autosampler Motherboard (ALM) Figure 125 Connectors ALM (Part I) Service Handbook for 1050 Series of HPLC Modules - 11/2001 327 Sampler: Electronic Information Autosampler Motherboard (ALM) Figure 126 Connectors ALM (Part II) 328 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Electronic Information Autosampler Motherboard (ALM) Figure 127 Connectors ALM (Part III) Service Handbook for 1050 Series of HPLC Modules - 11/2001 329 Sampler: Electronic Information Extender Test Board (ET) Extender Test Board (ET) Table 87 Part Numbers for Extender Test Board Item Part Number Extender Test Board 01078-66509 Cable Assembly 01078-61609 The extender test board in combination with the cable assembly allows the operation of sampling unit metering drive and high pressure switching valve taken out of the autosampler module. The test board contains all the connectors for the different items and holds some electronic for troubleshooting and sensor adjustment. Figure 128 shows the circuit diagram of the test board. The LED’s CR1 to CR7 show the actual status of the sensors. An LED which is ON indicates that the sensor is either blocked or deactivated. The sensors are only activated during the injection cycle. Figure 128 Extender Test Board 330 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Electronic Information Extender Test Board (ET) Figure 129 Circuit Diagram ET Board Service Handbook for 1050 Series of HPLC Modules - 11/2001 331 Sampler: Electronic Information Extender Test Board (ET) 332 Service Handbook for 1050 Series of HPLC Modules - 11/2001 14 14 Sampler: Diagnostic Information This chapter provides information on error messages and diagnostic features of the 1050 Autosampler Sampler: Diagnostic Information This chapter provides information about • diagnostic steps • error messages • additional information 334 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Diagnostic Information Single Steps Single Steps The autosampler has several test functions which are part of the control section. The test functions provides access to the single steps of the injection sequence. If the 18596L/M sample tray (100 sample tray) is installed the firmware provides also single steps for this tray. Entering the Test Functions ❏ Press CTRL and with NEXT move the cursor to the TEST FUNCTIONS display and press ENTER. ❏ With the PREV or NEXT keys all of the single steps are accessible. N OT E This section describes only the function of the single steps. In case of malfunctions or error messages refer to the troubleshooting section of this manual. Service Handbook for 1050 Series of HPLC Modules - 11/2001 335 Sampler: Diagnostic Information Single Steps For The 21 Sample Tray Single Steps For The 21 Sample Tray C A UT I O N Single steps can be performed in any order and the step sequence is under the control of the operator. In case of incorrect step sequences damage of needle, seat, sample tray and other parts of the instrument might be possible. Multiple execution of the steps should be avoided because of occurring error messages or possible damage of the instrument. The single steps should always be performed with the inner cabinet installed. SINGLE STEP 1 SINGLE STEP 1 BYPASS The high pressure switching valve is activated and the mobile phase is directed to the column bypassing the metering device and the sampling unit. The correct switching of the valve is checked via a light sensor. Multiple execution of this step will create an error condition (E11). SINGLE STEP 2 SINGLE STEP 2 METERING HOME Metering device drives in the plunger to its mechanical limit named the home position. At home position a lever at the spindle system blocks the light path of a light switch. The metering device motor stops and reverses the direction until the lever has moved out of the light path. Multiple executions of this step are possible. SINGLE STEP 3 SINGLE STEP 3 NEEDLE UP Sampling unit raises needle. Interrupter sensor detects upper position of the needle. Multiple execution creates an error message (E13) because of the missing activation of the sensor. SINGLE STEP 4 SINGLE STEP 4 POS. MINITRAY Sample tray moves vial under needle. During the initialization of the autosampler the home position of the sample tray will be determined (hall sensor). From this home position the selected vial will be reached by counting the steps of the encoder, which is mounted to the tray shaft. Multiple execution of this step are possible. 336 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Diagnostic Information Single Steps For The 21 Sample Tray SINGLE STEP 5 SINGLE STEP 5 NEEDLE INTO VIAL Sampling unit lowers needle into vial. The stepper motor executes a defined number of steps to lower the needle. No sensor is involved in this action. Do not execute this step a second time. Otherwise the needle will be lowered again by the same number of steps. This means that the needle hits either the bottom of the vial or the plastic of the sample tray (if no vial is present). No error message will occur. SINGLE STEP 6 SINGLE STEP 6 DRAW UP Metering device withdraws plunger drawing up sample according to selected injection volume. For each injection volume the metering device motor performs certain steps to withdraw the plunger. Multiple execution of this step will withdraw the plunger until it reaches the maximum position. No error will occur. SINGLE STEP 7 SINGLE STEP 7 NEEDLE OUT Sampling unit raises needle out of vial. The needle motor is activated until stopped by the interrupter sensor, which is activated at upper position. Multiple execution of the step are possible without any problem (needle moves always up until it reaches the upper position and is moved back). SINGLE STEP 8 SINGLE STEP 8 MINITRAY HOME Sample tray moves back to home position. The number of encoder steps performed under step 4 will be executed in opposite direction. The home sensor is not involved in this action. Multiple execution of this step are possible without any problem (tray remains in home position). SINGLE STEP 9 SINGLE STEP 9 NEEDLE DOWN Sampling unit lowers needle into needle seat. Lower position is determined by the activation of the interrupter sensor. Multiple execution will create an error message (E19) because light path of sensor is already blocked. SINGLE STEP 10 SINGLE STEP 10 MAINPASS Switches switching valve to direct mobile phase through metering device and sampling unit and then into column. Light switch recognizes the change of the position. Multiple execution of this step will create an error message (E20) because the light switch will not be activated again. Service Handbook for 1050 Series of HPLC Modules - 11/2001 337 Sampler: Diagnostic Information Single Steps for the 100 Sample Tray Single Steps for the 100 Sample Tray If the 18596L/M 100 sample tray is connected to the autosampler the firmware provides also single steps capability for this tray. Entering the Additional Single Steps ❏ Press CTRL and with NEXT move the cursor to the TEST FUNCTIONS display and press ENTER. ❏ With the PREV NEXT keys move to the display SINGLE STEPS 100 vial tray and press ENTER. N OT E This section describes only the function of the single steps. In case of occurring malfunctions or error messages refer to the troubleshooting section of this manual. C A UT I O N Single steps can be performed in any order and the step sequence is under the control of the operator. In case of incorrect step sequences damage of gripper assembly tray arm and other parts of the instrument might be possible. Multiple execution of the steps should be avoided, because of occurring error messages or possible damage of the instrument. SINGLE STEP 1 SINGLE STEP 1 INIT 100 TRAY 100 sample tray performs an initialization. Multiple execution of this step causes no problem. SINGLE STEP 2 SINGLE STEP 2 MOVE TO POS 101 From the home position the tray arm moves to the position 1 of the 100 sample tray. The firmware does not support access to other vials. Do not execute the step a second time. Otherwise the arm performs the same number of steps again and moves into the mechanical stop. SINGLE STEP 3 SINGLE STEP 3 PICK UP VIAL The gripper assembly moves down, picks up the bottle and the gripper moves up to home position (determined by a hall sensor). Second execution of this step will lead to incorrect position in step 4. 338 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Diagnostic Information Single Steps for the 100 Sample Tray SINGLE STEP 4 SINGLE STEP 4 MOVE TO 21 TRAY Tray arm moves vial to the 21 sample tray position and stops above vial position 16 of the tray. Do not execute this step a second time, because the arm would move into the mechanical stop. SINGLE STEP 5 SINGLE STEP 5 INSERT VIAL Gripper assembly moves down and places the vial into the 21 sample tray and gripper returns to home position. Down position of the gripper can be influenced via the teach tray mode. Do not execute the step a second time. Otherwise incorrect positioning of the tray arm will occur and the following steps might show incorrect results. SINGLE STEP 6 SINGLE STEP 6 REMOVE VIAL Gripper assembly picks up the vial from the 21 tray. Step is similar to step 2. SINGLE STEP 7 SINGLE STEP 7 MOVE TO POS 101 From the 21 sample tray the arm moves back to the position 1 of the 100 sample tray. Second execution should be avoided, otherwise the tray arm moves into the mechanical stop. SINGLE STEP 8 SINGLE STEP 8 INSERT VIAL The gripper assembly moves down and replaces the vial into its original position. SINGLE STEP 9 SINGLE STEP 9 HOME 100 TRAY The tray arm is moved back to the home position. This step is not identical with the initialization of the tray arm. Service Handbook for 1050 Series of HPLC Modules - 11/2001 339 Sampler: Diagnostic Information 18596L/M Sample Tray Diagnostic Mode 18596L/M Sample Tray Diagnostic Mode Tray diagnostics mode isolates sample tray motion in each of the Z (gripper arm), R (radial movement of tray arm) and Theta (angular movement of tray arm) direction. Entering Diagnostic Mode ❏ Turn off power at the 79855A autosampler. ❏ Take out the MTD board and put the RUN-TEST jumper J13 into TEST position. ❏ Replace the board. ❏ Take the sample quadrants out of the 18596L/M sample tray, if not taken out interference in Z direction will occur. ❏ Turn on line power and the 18596L/M will go automatically into the Z test. Z Test (Gripper Assembly) First the tray will home itself to the Z sensor at the top of travel. The tray will then drive the gripper down in Z back up to the sensor and up further to the mechanical stop. If the test passed (for example no problem in Z direction), the tray will pause two seconds and then it will repeat the test. If the bottle switch is pressed after passing the test, the sample tray will advance to the R test. N OT E If the Z sensor was not found (due to shorted motor, board problem, bad flex circuit, bad sensor, and so on), the test will abort. Turn off the autosampler and turn on again to restart the test. Pressing the bottle switch when in this error condition will advance the sample tray to the R test. 340 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Diagnostic Information 18596L/M Sample Tray Diagnostic Mode R Test (radial arm movement) First the arm will drive to the hard stop in R and locate the R sensor. The arm will then be driven out to full extension in R, back to the R sensor and back to the hard stop. If the test was passed, the sample tray will pause two seconds and then it will repeat the R test. If the bottle switch is pressed after passing the test, the sample tray will advance to the Theta test. N OT E If the R sensor was not found, the test will abort. Turn off the autosampler and on again to restart the test. Pressing the bottle switch when in this error condition will advance the sample tray to the Theta test. Theta Test (angular movement) First the sample tray will home itself in R and Theta direction. The R axis is homed so that the Theta motion can be made with R in its normal operating position. Failure of the R axis to home will not prevent the Theta test from running. The Theta test drives both R and Theta motors. After homing R and Theta, the arm will rotate 180° counter-clockwise, 360° clockwise and 180° counter-clockwise and check for the Theta sensor. If the test was passed, the tray will pause for two seconds and then it will repeat the test. If the bottle switch is pressed after passing the test, the sample tray will advance to the Z test. N OT E If motor steps are lost, the test will abort. Turn off the autosampler and on again to restart the Z and R test. Service Handbook for 1050 Series of HPLC Modules - 11/2001 341 Sampler: Diagnostic Information Error Messages Error Messages The error messages will help to locate and repair a possible failure. In case an error message appears the Error LED will be turned on and the message will be written into the system logbook. RESET INJECTOR clears the error message. The entry in the logbook remains. The error messages are divided into the following blocks: • Selftest • PANIC Error • Common 1050 Messages • Error Messages for Firmware Revision 4.0 and greater • Injector Program • Error Messages for Firmware Revision 3.1 and below • Events • 18596L/M vial tray 342 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Diagnostic Information Error Messages Selftest RAM and display can be tested via the build in selftest. The selftest will be performed when CTRL will be pressed while the module is turned on at the LINE ~ switch. In case of a failure one of the following messages appears. The complete test requires approximately two minutes. ROM test failed ( ROM test failed ) The ROMs on the FIM board are tested. In case of a checksum error the ROM test fails. Replacement of the FIM board will probably fix the problem. RAM test failed ( RAM test failed ) The RAM’s on the CMP board will be tested. In case of a failure the error message appears and the CMP has to be replaced. Panic Error Bus Error Address Error PANIC: XXXXXXH BUS ERROR PANIC: XXXXXXH Address ERROR The panic error messages should not appear under normal operation conditions. In case of hardware or firmware problems the instrument might try to access a wrong or not existing address which results in the error message on the display. The instrument is locked up and has to be switched off/on. Reason for the PANIC error message can be any disturbance on the bus lines due to bad contacts (high resistance) or defective IC on any of the boards. ❏ Check boards for good connections or corrosions at the contacts (clean contact pins). ❏ Check firmware revision of the firmware board (SWF). It should be revision C or higher. Boards with revision C do have a dynamic bus termination for spike suppression on the bus lines. ❏ Replace one board at a time to identify the faulty one. ❏ If board replacement will not cure the problem, replace the motherboard. Service Handbook for 1050 Series of HPLC Modules - 11/2001 343 Sampler: Diagnostic Information Common 1050 Error Messages Common 1050 Error Messages The common messages are either event or error messages which may appear in all the 1050 series modules. The messages are identical or very similar in the various modules. E00 : Power Fail E00 HH:MM DDMMM power fail This event message indicates that the instrument has either been turned off or disconnected from line source or a line power voltage drop has occurred. The system clock will stop and has to be set after turning on the module. E01 : Leak Detected In E01 HH:MM DDMMM leak detected > Detector leak detected > in injector The leak detection system uses a PTC resistor as leak sensing item. Liquid cooling the PTC results in a decrease of the resistance. The PTC is built in a resistor divider which is connected to a constant voltage. From the voltage divider a signal can now be obtained depending on the current through the PTC and hence depending on the temperature. The leak detection circuit is located on the CMP board and checks continuously for presence and leak conditions. If the sensor is missing (defect) or in leak condition the PTC is cooled down the error message appears. When the module is turned on the leak message will be disabled for some time (30 seconds) to allow the sensor to reach its working range. Working condition of the PTC Normal: about 75°C 400...500 Ohm Error: below 55°C about 150 Ohm Actions: ❏ Check for leaks in autosampler. ❏ Check connector of the sensor. ❏ Check resistance of leak sensor. ❏ Change leak sensor. ❏ Change CMP board. ❏ Change FIM board. 344 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Diagnostic Information Common 1050 Error Messages E02 : Shut down E02 HH:MM DDMMM shut down > error in other module An external device pulled the shut down line of the remote connector down. This forces the autosampler to stop all further injections. E03 : Error Method loaded E03 HH:MM DDMMM error method > error method has been loaded The operator may define an method as a error method. The event message gives the information that the instrument detected an error and that the error message has been loaded. E04 : Time Out E04 HH:MM DDMMM time out > The operator may define a time period after which the instruments stops all further actions. In case the instrument is in a sequence and a not ready has been detected in one of the other modules the instrument will stop the sequence after time out time has been elapsed. Service Handbook for 1050 Series of HPLC Modules - 11/2001 345 Sampler: Diagnostic Information Error Messages for Firmware Revision 4.0 and greater Error Messages for Firmware Revision 4.0 and greater N OT E Firmware revision 4.0 and greater incorporates the injector program for the autosampler. The injector program required a restructure of the internal code of the injection cycle. Therefore some of the error messages had to be removed. This section shows the error messages for the current firmware revision 4.0 and greater. Nevertheless the same messages appear also in all the previous firmware versions. The additional error messages for firmware version 3.1 and below are described in section “Normal Operation Messages for Firmware Revision 3.1 and below” on page 351. The following messages might appear during the initialization, the injection cycle and a reset of the injector. At initialization and reset the system sets all components (sampling unit, metering device and high pressure switching valve) to home position. Missing or low air pressure will not result in an error condition. When started, the injection cycle will perform all the steps which are necessary to introduce the sample into the flow path. E11 : Valve not moved E11 HH:MM DDMMM inject failed > to bypass valve not moved to bypass A light switch controls the movement of the high pressure switching valve. In case the sensor does not see a dynamic signal change the error message appears. Reason might be missing air (air pressure message?), a misadjusted lights witch or failures in the electronic circuit. ❏ Check air supply. ❏ Check sensor adjustment. ❏ Check wether the solenoid is activated. ❏ Change the VMD board. ❏ Change the sensor. 346 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Diagnostic Information Error Messages for Firmware Revision 4.0 and greater E13 : Needle has not been raised E13 HH:MM DDMMM inject failed > needle has not been raised The motor is activated and moves the needle arm out of the seat or vial. In the upper position the interrupter pin blocks the light path of the interrupter sensor. The motor is stopped and the interrupter pin is moved out of the lights witch. Both positions upper limit and lower limit are determined by the same lights witch (interrupter sensor). ❏ Check for blockages of the sensor. ❏ Check for proper connection of motor and sensor. ❏ Check for smooth movement of the spindle system. ❏ Check for smooth movement of the bottle vane (bottle sensor). ❏ Check drive nut. ❏ Change NMD board. ❏ Change interrupter sensor. E14 : Vial position not E14 HH:MM DDMMM inject failed > found vial position not found During the initialization, the sample tray determines its home position (magnet above home sensor). The shaft encoder mounted onto the tray coupler provides the information to reach the various vial positions of the tray. If the selected position cannot be reached the error message will appear. Possible failure modes are blockages of the mechanical system, defective encoder or a electronic problem. ❏ Check for mechanical blockages of the mechanical system (sample tray, tray coupler, belt and so on). ❏ Check all cable connections. ❏ Change NMD board. ❏ Change encoder. Service Handbook for 1050 Series of HPLC Modules - 11/2001 347 Sampler: Diagnostic Information Error Messages for Firmware Revision 4.0 and greater E18 : Home position of E18 HH:MMDDMMM inject failed > tray not found home position of tray not found After moving the requested vial to the injection position the sample tray moves back to its home position. The encoder checks the movement of the tray. If the tray cannot be moved the error message will appear. Failure modes might be mechanical blockages of the tray or problems from the encoder. ❏ Check for blockages of the system. ❏ Check Encoder signal. ❏ Check Home sensor signal. ❏ Change NMD board. E19 : Needle has not been lowered E19 HH:MM DDMMM inject failed > needle has not been lowered From the upper position the needle gets the command to move down into the seat or vial. In case of malfunctions the error appears. A defective bottle in place sensor might also generate the error. ❏ Check the needle motor and sensor connection. ❏ Check for blockages of the mechanical system. ❏ Check sensor signal. ❏ Check for smooth movement of the bottle vane (bottle sensor). ❏ Lubricate bottle vane. ❏ Change NMD board. ❏ Check bottle in place sensor. E20 : Valve not moved E20 HH:MM DDMMM inject failed > to mainpass valve not moved to mainpass Last step in the injection sequence is to turn back the high pressure switching valve into its main pass position. Problems in the air supply, sensor or board problems may cause the error message to appear. ❏ Check the pneumatic assembly. ❏ Check cable connections. ❏ Check sensor adjustment. ❏ Change VMD board. 348 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Diagnostic Information Error Messages for Firmware Revision 4.0 and greater E22 : Plunger home position not found E22 HH:MM DDMMM inject failed > plunger home pos not found The plunger of the metering device is moved forward until the home position sensor indicates the maximum allowed front position. In case the home sensor cannot be recognized the plunger moves into the mechanical stop. The motor will be stopped after the programmed time out has been elapsed. Second possibility is that the motor does not start and the plunger will not move at all. After time out the error message appears. Possible failure modes are a misadjusted or defective sensor or a defective motor. ❏ Check for proper connection of motor and sensor. ❏ Change VMD board. ❏ Check alignment of sensor. ❏ Change sensor. E24 : Tray home position not found E24 HH:MM DDMMM inject failed > tray home pos not found During the initialization the sample tray determines its home position (magnet above home sensor). If the home position could not be recognized the error appears (for example sample tray not installed). At the begin of an injection the system checks for the presence of the home sensor. If this cannot be recognized the tray will be positioned incorrectly and the error will show up. ❏ Check the magnet of the sample tray. ❏ Check for mechanical blockages of the mechanical system (sample tray, tray coupler and so on). ❏ Check tray motor. ❏ Change encoder. ❏ Change NMD board. Service Handbook for 1050 Series of HPLC Modules - 11/2001 349 Sampler: Diagnostic Information Injector Program Error Messages Injector Program Error Messages The injector program introduced with the firmware revision 4.0 and greater comprises the programmable functions such as draw eject and mix sample. This allows to program particular injections for the autosampler. The injector program will be part of the method when stored. E16 : Plunger failed to E16 HH:MM DDMMM inject failed > draw/mix/eject inject failed to draw/mix/eject sample sample The program line cannot be performed because a lack of draw, eject or mix volume is left in the syringe. Use the verify function to identify the faulty program line and correct the volume. E97 : Program wait time elapsed E97 HH:MM DDMMM inject failed > program wait time elapsed The utility functions allow to wait for remote line changes. If a remote line change has not occurred before the time-out has elapsed, the error occurs. E98 : no device for vial E98 HH:MM DDMMM inject failed > no device for vial The vial number used exceeds the limit of the vial range. This is possible when using the SAMPLE+ command (adding a number to the actual vial number) in the injector program. This function cannot be tested with the verify function. E98 : Volume exceeds E98 HH:MM DDMMM inject failed > limit volume exceeds limit Incorrect setting of draw/eject commands may lead to a limit violation for the injection volume. This function cannot be tested with the verify if the volume was determined via the “def” command. 350 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Diagnostic Information Normal Operation Messages for Firmware Revision 3.1 and below Normal Operation Messages for Firmware Revision 3.1 and below N OT E Following error messages describe the failure modes for instruments with firmware revision 3.1 and below. The error messages will appear in addition to the errors described before for revision 4.0 and greater. E12 : Plunger home position not found E12 HH:MM DDMMM inject failed > plunger home pos not found The plunger of the metering device is moved forward until the home position sensor indicates the maximum allowed front position. In case the home sensor cannot be recognized, the plunger moves into the mechanical stop. The motor will be stopped after the programmed time out has been elapsed. Second possibility is that the motor does not start and the plunger will not move at all. After time out the error message appears. Possible failure modes are a misadjusted or defective sensor or a defective motor. ❏ Check for proper connection of motor and sensor. ❏ Change VMD board. ❏ Check alignment of sensor. ❏ Change sensor. E15 : Needle did not move into vial E15 HH:MM DDMMM inject failed > needle did not move into vial The system assumes that the needle is in its upper position. From this position the needle will be lowered into the vial. The processor determines how many steps the motor has to perform. This information will be send to the NMD board. In case the needle will not be lowered a electrical malfunction should be the failure mode. ❏ Check connection of the needle motor. ❏ Change NMD board. Service Handbook for 1050 Series of HPLC Modules - 11/2001 351 Sampler: Diagnostic Information Normal Operation Messages for Firmware Revision 3.1 and below E16 : Plunger failed to E16 HH:MM DDMMM inject failed > draw sample plunger failed to draw sample From the home position the plunger is moved back a certain number of steps to draw the requested volume. Failure mode is the electronics of the VMD board. ❏ Check connections of metering motor. ❏ Change VMD board. E17 : Needle did not move out of vial E17 HH:MM DDMMM inject failed > needle did not move out of vial The needle motor is activated to move the needle in its upper position. If this action fails the error appears. Possible failure mode is the interrupter sensor, spindle motor or the NMD board. ❏ Check interrupter sensor. ❏ Change NMD board. E23 : Needle has not been raised E23 HH:MM DDMMM init failed > needle has not been raised During this step the needle is raised from any position. In case this step fails the error message appears. ❏ Check for blockages of the sensor. ❏ Check for proper connection of motor and sensor. ❏ Check for smooth movement of the spindle system. ❏ Check drive nut. ❏ Change NMD board. ❏ Change interrupter sensor. 352 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Diagnostic Information Normal Operation Messages for Firmware Revision 3.1 and below E25 : Needle has not been lowered E25 HH:MM DDMMM init failed > needle has not been lowered From the upper position the needle driver gets the command to move the needle down into the seat. In case of malfunctions the error appears. Firmware revision 2.0 and above connect the functioning of the needle sensor and the bottle in place sensor. If the bottle in place sensor is defective the error will also appear. ❏ Check the needle motor and sensor connection. ❏ Check for blockages of the mechanical system. ❏ Check for smooth movement of the bottle vane (bottle sensor). ❏ Lubricate bottle vane. ❏ Check sensor signal of interrupter and bottle in place sensor. ❏ Change NMD board. Service Handbook for 1050 Series of HPLC Modules - 11/2001 353 Sampler: Diagnostic Information Events Messages Events Messages Event messages give the operator informations about the performed action of the instrument. Messages will appear in the logbook. E26 : No vial in sam[ple tray E26 HH:MM DDMMM missing vial > no vial in sample tray During the injection sequence the bottle in place sensor checks for the presence of a vial. If no vial is in the tray the message appears in the logbook. Depending on the system configuration (stop/cont/skip at missing vial), the message is interpreted as an error or a event message. If the vial sensor is not connected or defective error message E19 will appear. ❏ Place a bottle into vial position. ❏ Check bottle in place sensor. ❏ Check cabling of sensor board. ❏ Change sensor. ❏ Change NMD board. E29 : Sequence done E29 HH:MM DDMMM sequ done > sequ exec finished Sequence finished is an event message. It records the correct termination of an automated operation. E30 : Sequence aborted E30 HH:MM DDMMM sequ aborted > sequ exec aborted Sequence either stopped by operator or error occurred during operation. In case of an error the Error lamp will be on. Check next logbook line for more information. 354 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Diagnostic Information 18596L/M Vial Tray 18596L/M Vial Tray The following error messages may occur when the 100 sample tray is connected to the autosampler. E31 : Vial in claw E31 HH:MM DDMMM init failed > vial in claw remove vial! After turning on the autosampler or the reset command the 18596L/M performs an initialization. The initialization fails when there is a bottle in the claw. If the initialization fails the Error lamp is on and the message appears in the logbook. ❏ Remove vial from the claw and reset system. ❏ Check bottle sensor. E32 : Cannot remove vial from device E32 HH:MM DDMMM inject failed > cannot remove vial from device The 18596L/M sample arm tried to take a vial out of its own tray or the 21 sample tray and failed. ❏ Check claw position in teach tray mode. E33 : Cannot insert vial in device E33 HH:MM DDMMM inject failed > cannot insert vial in device The 18596L/M sample arm tried to place a vial either in the transfer position of the 21 sample tray or the 100 sample tray and failed. Most common reason is the presence of a vial in this position. It is also possible that the claw position was not correctly set in the tray teach mode. ❏ Remove vial from selected position. ❏ Check claw position in teach tray mode. Service Handbook for 1050 Series of HPLC Modules - 11/2001 355 Sampler: Diagnostic Information 18596L/M Vial Tray E34 : Failed to home axis E34 HH:MM DDMMM inject failed > serious error in 100 vialtray Error appears when the tray arm is not able to move to its selected position. ❏ Reset autosampler. ❏ Check cable connection. ❏ Change MTD board. ❏ Check tray arm. E35 : Teach of 100 vial E35 HH:MM DDMMM teach done > tray done teach of 100 vialtray done Event message indicating use of the teach tray function. E36 : Vial number for unknown device E35 HH:MM DDMMM teach done > teach of 100 vialtray done This error appears when an incorrect vial range has been set. Example: The vial range was specified 1 to 30 for the 34 vial tray. When the 21 vial tray is installed the autosampler will show error E36 when reading 22 or greater. E38 : Barcode verification failed E38 HH:MM:DDMMM verified failed barcode verification failed The error can only be seen when the DOS workstation is connected to the autosampler with 100 vial tray and barcode reader. The label from the vial will be verified with the setting for the analyzed vial position. A mismatch will generate the error message. ❏ Check vial label and computer information for correctness. ❏ Check/replace barcode reader and driver board. E39 : Error state of 100 E39 HH:MM:DDMMM injector aborted > vial tray error state of 100 vial tray The error appears when a previous error on the 100 vial tray is still present (error LED blinking) and a new action for the 100 vial tray has been started. 356 Service Handbook for 1050 Series of HPLC Modules - 11/2001 15 15 Sampler: Maintenance Information This chapter provides provide procedures for service and maintenance of the 1050 Autosampler Sampler: Maintenance Information This chapter describes the procedures that have to be performed during servicing and maintenance of the 1050 Autosampler. You will find procedures for: • Sampling Unit • Metering Device • Analytical Head • High Pressure Switching Valve • Sensor Adjustments 358 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Maintenance Information Sampling Unit Sampling Unit N OT E Needle and needle seat changes can be performed without removing the sampling unit. For stage 2 it is necessary that the needle is in the needle change position. Stage 1: Removing the Sampling Unit ❏ Remove front door. ❏ Remove the Sample Tray. ❏ Remove the Inner Cabinet. ❏ Remove the Leak Tub. ❏ Disconnect the loop capillary either at the needle or at the switching valve. ❏ Disconnect the seat capillary at the switching valve. ❏ Disconnect all cables of the sampling unit from the motherboard. ❏ Remove the holding screw of the sampling unit. ❏ Slide the unit backwards and then to the right to remove it from its place. ❏ Take out the sampling unit. Service Handbook for 1050 Series of HPLC Modules - 11/2001 359 Sampler: Maintenance Information Sampling Unit Stage 2: Removing the Needle ❏ Move the needle in the needle change position (Control Configuration). ❏ With the Pozidrive# 2 loosen the clamp screw. ❏ Turn the needle with the ZDV fitting out of its recess and lift the needle to get it out of the clamp screw. ❏ Disconnect the needle from the ZDV fitting. ❏ Needle with laser welded fitting: Disconnect the loop capillary from the needle fitting Figure 130 Needle Change 360 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Maintenance Information Sampling Unit Stage 3: Installation of the Needle N OT E If a new needle will be installed the needle seat should be changed too otherwise leaks might be possible. ❏ Needle with laser welded fitting: Connect the loop to the needle fitting and tighten it. ❏ Connect the new needle to the ZDV fitting and screw it hand tight. ❏ Insert the needle into the groove behind the clamp plate and swing the ZDV fitting back to the recess. ❏ Tighten the connection at the ZDV fitting (only old version). ❏ Tighten the clamp screw. N OT E No further needle adjustment necessary. In case the needle is not straight carefully bend the needle for proper alignment. Stage 4: Removing the Seat Capillary N OT E To avoid possible leaks, it is recommended to install a new needle seat when the seat capillary will be changed. ❏ Raise the needle (Control Test Functions). ❏ With a wrench 5/16” unscrew the seat and remove it. ❏ Remove the seat capillary from the socket. ❏ Disconnect the seat capillary at the High Pressure Switching Valve. Service Handbook for 1050 Series of HPLC Modules - 11/2001 361 Sampler: Maintenance Information Sampling Unit Stage 5: Disassembling the Needle Arm N OT E Follow the steps of this procedure when replacing either guide rod, spindle, needle arm or drive nut. ❏ Remove needle (make sure that the needle is in its change position or turn the motor coupler to reach it) and interrupter sensor (only in case of sensor or needle arm change readjustment necessary). ❏ Loosen the set screw for the guide rod and remove it from the sampling unit. It might be necessary to use a mallet and a punch pin to get the guide rod out. ❏ Remove the retainer on top of the spindle and save retainer and spring disc. ❏ Loosen the screw of the motor coupler which holds the spindle. ❏ Move the needle arm up to move the spindle out of its ball bearing (some force is required). ❏ Remove the brass bearing sleeve from the top shaft of the spindle and carefully take out the assembly. Stage 6: Reassembling the Needle Arm ❏ Insert the spindle into the top hole and then insert the small shaft into the ball bearing. ❏ Push the motor coupler as close as possible to the bearing and fix it in this position. ❏ Insert the guide rod and fix it with the set screw. ❏ Insert the spindle bearing sleeve and the spring disc at the top of the unit and mount the retainer. ❏ Reinstall needle and interrupter sensor and perform required adjustments (see “Adjustment of Interrupter Sensor with test board” on page 377). 362 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Maintenance Information Sampling Unit Stage 7: Disassembling the Tray Mechanic N OT E Follow this instructions when either changing Tray Motor, Gear, Belt, Tray Coupler, toothed wheel or Quadrature Encoder, see Figure 131 on page 364. ❏ Remove bottom cover of the sampling unit. ❏ Remove the tray Motor. N OT E The Tray Motor is fixed from the bottom. Loosening the four screws on top of the motor will damage the tray motor. ❏ Remove the belt N OT E The belt roller will be pressed to the belt to stretch it. But the pretension of the belt should not affect the smooth movement of the tray coupler. ❏ Remove the black cap in the sample unit housing to get access to the two set screws of the coupler toothed wheel. ❏ Loosen the set screws and remove the coupler from the unit. ❏ Carefully slide the toothed wheel out of its place, see Figure 131 on page 364. N OT E The toothed wheel is coupled with the encoder slit wheel which is running in the quadrature encoder. Take care not to damage the slit wheel while lifting the assembly. ❏ Disconnect the cable of the encoder unscrew it and take it out. N OT E The encoder cable is not keyed. Make sure that position 1 of the cable is connected to position 1 of the encode, see Figure 131 on page 364. If the cable is positioned in the wrong direction the system cannot initialize the tray. The behavior is like with a defective home sensor. Service Handbook for 1050 Series of HPLC Modules - 11/2001 363 Sampler: Maintenance Information Sampling Unit Figure 131 Bottom View of the Sampling Unit 364 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Maintenance Information Metering Device Metering Device N OT E Move the plunger into the plunger change position before removing the metering device from the instrument. Removing the Metering Device ❏ Remove Top Cover. ❏ Disconnect the two capillaries to the head of the Metering Device. ❏ Disconnect motor and sensor cable. ❏ Remove the transport securing screw. ❏ Remove the screw which fixes the Metering Device on the High Pressure Switching Valve. ❏ Take out the Metering Device. Removing the Gear Belt ❏ Remove the cover of the gear box. ❏ Remove the stepper motor. ❏ Take out the gear belt. Service Handbook for 1050 Series of HPLC Modules - 11/2001 365 Sampler: Maintenance Information Metering Device Analytical Head Assembly There are two different versions of the analytical head available. In the latest version the spring is integrated in the adapter housing. The following table shows the serial number prefix at introduction of the new adapter housing design. Table 88 N OT E New Analytical Head Assembly Autosampler SN Prefix Version 79855A/B 3404 G ..... new; Procedure2 79855A/B 3406 A ..... new; Procedure 2 Follow this instruction when either changing Plunger Seal or Plunger. Do not forget to use the plunger change position in the control section before removing the analytical head assembly. The numbers in brackets refer to Figure 132 on page 367. Procedure 1: Analytical Head Assembly with old Adapter Housing Stage 1: Disassembling the Analytical Head Assembly ❏ Unscrew the Analytical Head Assembly and remove it from the Metering Drive. ❏ Place the Assembly on its round head (13) and remove the two screws (14). ❏ Carefully pull the head (13) to separate it from the body (9). N OT E Do not twist the head while pulling. This could break the plunger. 366 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Maintenance Information Metering Device Stage 2: Changing the Seal ❏ Remove the seal keeper (11) from the head (13). ❏ Using the three millimeter hexagonal key remove the seal (12). ❏ Clean the head chamber (13) from all seal particles. Best is to use a degreaser spray (for example 8500-0232). ❏ Insert a new seal (12). Stage 3: Disassembling the Body ❏ Remove the support ring (10) or the support seal assembly. ❏ Hold the body down on a flat surface loosen the setscrew (15) and carefully release the tension of the spring. WA R N I N G The spring will catapult the body up if released without holding it. Figure 132 Analytical Pump Head Assembly (old) Service Handbook for 1050 Series of HPLC Modules - 11/2001 367 Sampler: Maintenance Information Metering Device Stage 4: Reassembling the Analytical Head Assembly ❏ Place sapphire plunger (7) and spring (8) into the spring support (6). ❏ Place the adapter (9) on a flat surface and insert the parts from the previous step. ❏ Hold the adapter (9) from one side with the thumb and press the spring support (9) with plunger and spring with the fingers into the body. ❏ Hold the spring support (6) with one hand in place and fix the setscrew. ❏ Slide the support ring (10) or the support seal assembly onto the plunger. N OT E If the support ring (10) or the support seal assembly sticks at the body when sliding down the plunger push the plunger (7) slightly from the bottom. This will center the plunger and the ring keeper slides into its position. ❏ Place the seal keeper (11) on the seal (12) of the head. N OT E In this position the seal keeper guides the plunger into the seal and reduces the possibility to break the plunger. ❏ Carefully place the head (13) onto the adapter (9). ❏ Turn the assembly upside-down insert the screws (14) and fix them stepwise with increased torque. N OT E It is important that the surface of head and adapter are parallel to each other to obtain a good seal. 368 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Maintenance Information Metering Device Procedure 2: Analytical Head with new Adapter Housing Stage 1: Disassembling the Analytical Head Assembly ❏ Unscrew the Analytical Head Assembly and remove it from the Metering Drive. ❏ Place the Assembly on its round head (6) and remove the two screws (2). ❏ Pull the adapter (3) straight up from the head (6) being careful not to put any sidewards strain on the sapphire piston (1), since it could shear and break. ❏ Put the adapter housing (3) aside taking care to avoid dropping the piston (1) from the housing. N OT E The piston is not secured in the adapter housing and will fall out when the housing is turned upside down. ❏ Remove the piston (1) from the adapter (3). ❏ Check for scratches and dirt on the piston. N OT E Dirt on the piston surface can be removed by using a small quantity of toothpaste. Stage 2: Changing the Seal ❏ Remove the support seal assembly 4) from the head (6). ❏ Using the three millimeter hexagonal key remove the seal (5). ❏ Clean the head chamber (6) from all seal particles. Best is to use a degreaser spray. ❏ Insert a new seal (5). ❏ Place the support seal assembly (4) onto the seal (5). Service Handbook for 1050 Series of HPLC Modules - 11/2001 369 Sampler: Maintenance Information Metering Device Figure 133 Analytical Pump Head Assembly (new) Stage 3: Reassembling the Analytical Head Assembly ❏ Prepare the head (6) as described beforehand. ❏ Place the adapter housing (3) without the piston (1) onto the head (6). ❏ Insert the two screws (2) and tighten until hand tight. N OT E Tightening the screws fully will require much more force to push the piston into its position in the seal. ❏ Insert the piston (1) into the adapter housing (3) and carefully push it into the seal. ❏ Tighten the two screws (2) stepwise with increasing torque. Make sure that head and adapter surfaces are in parallel. 370 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Maintenance Information Metering Device Reassembling the Metering Device ❏ Put the Analytical Head Assembly onto the metering drive and insert the two screws. N OT E The Head Assembly should be installed like shown in Figure 132 on page 367 or Figure 133 on page 370. The capillary from the high pressure switching valve is connected to the bottom of the head assembly. ❏ Tight the screws stepwise with increasing torque. Service Handbook for 1050 Series of HPLC Modules - 11/2001 371 Sampler: Maintenance Information High Pressure Switching Valve High Pressure Switching Valve Stage 1: Removing ❏ Disconnect the air supply at the rear of the module. ❏ Remove the top cover. ❏ Remove front door and inner cabinet. ❏ Remove the leak tub. ❏ Remove the metering device. ❏ Disconnect all capillaries from the valve. ❏ Unscrew the holding screw at the base. ❏ Slide the unit out of its holder. ❏ Disconnect the air tubings. ❏ Take out the High Pressure Switching Unit. Stage 2: Disassembling ❏ Loosen and remove the three socket head stator screws (4). ❏ Remove the stator (2) from the top of the valve. ❏ Remove the stator ring from the valve. Take special care not to lose the stop pins in the stator ring. ❏ Using the blade of a screwdriver, release the rotor seal from the valve. 372 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Maintenance Information High Pressure Switching Valve Figure 134 High Pressure Switching Valve Service Handbook for 1050 Series of HPLC Modules - 11/2001 373 Sampler: Maintenance Information Adjust the Sensors Adjust the Sensors Adjusting of the sensors inside the instrument is very difficult. For that reason the extender test board (see chapter Electronics) has been designed. It allows to operate the assemblies outside of the instrument with easy access to the sensors. The firmware of the autosampler itself includes a service level which allows to verify the sensor positions and to perform the sensor adjustment. This section describes: • Service Only Level • Sensor adjustment Sampling Unit • Sensor adjustment Metering Device • Sensor adjustment High Pressure Switching Valve Service Only Level The service only will be accessed with a “password” to avoid accidental changes of parameters. N OT E Do not enter or change any numbers in this part which are not described in the following sections. Accidental change of system parameters could damage the instrument. Entering Service Only ❏ Press CTRL and with NEXT move the cursor to the < end of list >. ❏ Enter password (79855) and SERVICE ONLY will be displayed. ❏ With PREV or NEXT the following displays are accessible. EXECUTE STEP 1 INSTR# 1 VAL 1 ; 0 Read the notes on next page first. 374 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Maintenance Information Adjust the Sensors N OT E EXECUTE STEP allows the performance of the step commands (Test Functions) by entering the step number. #1 Switch Valve Unit to bypass. #2 Initialize Metering Device. #3 Raise needle. #4 Move vial underneath needle. #5 Lower needle. #6 Draw sample up from sample vial. #7 Raise needle. #8 Move vial to home position. #9 Lower needle. #10 Switch Valve Unit to flow through sample loop. INSTR# allows to read the position of the various sensors and can be used for adjustment of sensors. An negative number (for example -2) writes the actual value into the processor memory for adjustment calculations. For more information see chapter sensor adjustment. #1 Reads the position of the shaft encoder. for example INSTR# 1 VAL 1 ; 0 #2 Reads the left stop of the sample tray. for example INSTR# 2 VAL -56 ; -56 #3 Reads the right stop of the sample tray. for example INSTR# 3 VAL 53 ; 53 #4 Calculate correction value for measurement performed under #2 and #3. The result is shown in µm. for example INSTR# 4 VAL 251 ; 251 #5 Reads the data which represents the actual sensor status for the complete sampling unit (interrupter home and bottle sensor). for example INSTR# 5 VAL 227 ; 227 after initialization. Depending on the sensor which is activated or not the value changes in increments of 1, 4, 8. 8 for the sample tray 4 for the bottle in place sensor 1 for interrupter sensor. Service Handbook for 1050 Series of HPLC Modules - 11/2001 375 Sampler: Maintenance Information Adjust the Sensors N OT E #6 Reads the data which represents the actual sensor status for the metering home sensor and the valve position sensor. Readings can be used for sensor adjustment or troubleshooting. for example INSTR# 6 VAL 240 ; 240 after initialization. Depending on the sensor which is activated or not the value changes in increments of 1 or 8. 8 for the metering device home sensor. 1 for the valve position sensor. Sensors of the Sampling Unit N OT E Four sensors are controlling the various functions of the sampling unit. N OT E Interrupter Sensor: Initializes a signal to stop the needle motor at upper and lower limit. The adjustment ensures a defined force for the needle into the seat and determines the position of the needle in the sample vial during the injection cycle. Home Sensor: Determines the home position of the sample tray. The processor counts the selected vial number relative to the home position. Adjustment ensures that the needle hits the septa of the sample vial in each vial position. Bottle in Place Sensor Checks for presence of a vial during the injection cycle. No adjustment required. Quadrature Decoder Checks the actual position of the 21 sample tray for adjustment of the 21 vial tray. If the 34 vial tray is installed the more precise procedure should be selected. No adjustment required. The home sensor will be adjusted with the build in service level test features. For the interrupter sensor there are two adjustment procedures available. Adjustment can be done via the extender test board which is the easiest way because of the accessibility of the sensor. If the test board is not available the features of the service level also allow adjustment of the sensor. 376 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Maintenance Information Adjust the Sensors Adjustment of Interrupter Sensor with test board ❏ With the test functions commands move the needle into upper position. ❏ By turning the motor coupler move the needle arm downwards until the interrupter pin just touches the upper plate. ❏ Now move the needle arm upwards 1 mm. N OT E One revolution of the spindle moves the needle arm 1.5 mm up. Therefore 240° represent 1 mm. ❏ Position the sensor that the LED on the extender board just changes its state from on to off (should remain off) and fix it in this position. Adjustment of Interrupter Sensor via Service Only Level ❏ Follow steps 1 to 3 of the previous described procedure. ❏ Enter SERVICE ONLY level. ❏ Move to the Instr# and enter #5 to get the following display. INSTR# 5 VAL 239 ; 239 (without sample tray) ❏ Position the interrupter sensor that the value just changes to 238. Move it back until you reach 239 and fix it in this position. Adjustment of Home Sensor - procedure for 21/34 vial tray N OT E During RESET of the autosampler the processor finds the home position of the sample tray and stores the actual dehydrator encoder reading as zero position. The position of vial #1 is used as reference for the adjustment. With INSTR# 1 the processor reads the steps from the home position to the actual position. If the tray is aligned correctly the encoder should read the following values for the position of vial #1: 21 vial tray: VAL 0;-200 tolerance ±1 34 vial tray: VAL 0;-191 tolerance ±1 The above values can be obtained from the SERVICE ONLY level. Service Handbook for 1050 Series of HPLC Modules - 11/2001 377 Sampler: Maintenance Information Adjust the Sensors Adjustment Procedure ❏ Remove door, inner cabinet and the top cover from the autosampler. ❏ Make sure that the tray is installed correctly and that the vial is in position #1. ❏ Using the CTRL functions of the instrument RESET the autosampler. ❏ Enter the TEST FUNCTIONS. ❏ Use single steps 3 to raise the needle. ❏ In the display SINGLE STEP 4 POS. TRAY AT 10 change the vial position to 1 (use > ) and press 1 ENTER. They tray moves to position #1. ❏ The needle should point to the center of the vial. If not, turn the tray manually until the position is correct. ❏ *Enter the service only level and select the following display INSTR# 1 VAL 0; -XXX. N OT E XXX is the value for the actual position of the tray. If the home sensor is adjusted correctly, the value should be -191 ±1 for the 34 vial tray or -200 ±1 for the 21 vial tray. If XXX differs from the above values the sensor has to be adjusted. 6 counts represent approximately 1mm. ❏ Remove the tray, loosen the sensor screws and move the sensor ❏ Towards the front of the autosampler (ccw) when the actual values of XXX are larger then the nominal (for example -199 for 34 vial tray; or -205 for 21 vial tray). ❏ Towards the back of the autosampler (cw) when the actual value of XXX is smaller then the nominal (for example -185 for 34 vial tray; or -195 for the 21 vial tray). ❏ Verify the correct position. Insert the tray, RESET the injector and repeat step 4 to 8 of this procedure. 378 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Maintenance Information Adjust the Sensors Sensor of the High Pressure Switching Valve The sensor at the back side of the high pressure switching valve controls the correct movement of the valve. ❏ Take the high pressure unit out of the instrument and make connection to the extender test board for operation outside of the instrument. ❏ Make sure that the valve is in one of its end positions. ❏ Connect the sensor to the holding arm and move it until the LED on the test board becomes on. Then move it downwards until the LED just turns off and fix the board in this position. ❏ * Verify the proper operation of the high pressure switching valve. Adjustment of Valve Sensor via Service Only ❏ Follow step 1 to 2. ❏ Enter SERVICE ONLY level and move to the Instr# and enter #6 to get the following display. INSTR# 6 VAL 248 ; 248 (metering device in home position). ❏ Position the sensor that the display value just changes to 249. Move the sensor back until the value changes back to 248 and fix it in this position. ❏ Verify proper operation of the switching valve. Service Handbook for 1050 Series of HPLC Modules - 11/2001 379 Sampler: Maintenance Information Adjust the Sensors Metering Device Home Sensor The metering drive home sensor determines the maximum allowed front position of the plunger. A lever mounted to an spindle mechanism moves into the light switch to stop the motor. Adjustment is necessary that the plunger can not run into the mechanical stop of the analytical head and to be compatible with future options. The adjustment for the metering home sensor is not critical. Therefore a rough alignment without firmware support is sufficient. The sensor housing has a slot for the adjustment. Mount the sensor into a middle position of the sensor housing. Use the test functions to move the piston to home position. The plunger should stop before the mechanical stop. If the plunger moves into the stop adjust the sensor slightly back and try again. 380 Service Handbook for 1050 Series of HPLC Modules - 11/2001 16 16 Sampler: Parts Information This chapter provides information on parts of the 1050 Autosampler Sampler: Parts Information This chapter gives diagrams for parts identification and the complete parts listings respectively for the 1050 (Ti) Autosampler. • Electronic Boards • Ti - Parts • Overall Diagram • Solvent Flow Path • Sampling Unit • Metering Drive and Analytical Head • High Pressure Switching Valve • Pneumatic Valve Assembly 382 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Parts Information Electronic Boards and Fuses Electronic Boards and Fuses Electronic Boards Table 89 Electronic Boards Item Description Part Number Exchange 1 Power Supply Board DPS-B 5061-3374 01050-69374 2 Maxi Tray Drive Board for 18596A/L MTD 01078-66503 01078-69503 3 Maxi Tray Drive Board for 18596B/M MTD 01078-66513 01078-69513 4 Rotor Reader Drive Board RRC 01078-66507 5 Valve Metering Drive Board VMD 01078-66501 6 Firmware Board FIM 01078-66506 7 Needle Mini Tray Drive Board NMD 01078-66502 01078-69502 8 Communication Interface Board CIB 5061-3382 01050-69582 9 Common Main Processor Board CMP 50613380 01050-69580 10 Fluorescent Indicator Module FIP 5061-3376 11 Motherboard ALM 01078-66504 01078-69501 Fuses Table 90 Fuses Description Board Part Number Fuse 110V operation (3 A) DPS-B 2110-0003 Fuse 220V operation (2 A) DPS-B 2110-0002 Fuse F12, 250 mA VMD 2110-0004 Fuse: ICP1 1 A FIP 2110-0099 Service Handbook for 1050 Series of HPLC Modules - 11/2001 383 Sampler: Parts Information Complete List of Ti-Parts Complete List of Ti-Parts Following is a complete list of all special Ti parts. For the assemblies and accessories kits only the Ti parts are mentioned. Table 91 Complete List of Ti-Parts Description Part Number Description Part Number Ti - Needle 01079-67201 High Pressure Switching Valve Exchange 01079-60004 01079-69004 Ti - ZDV Fitting 5021-1871 Ti - Rotor Seal TEFZEL pH 12.5 0101-0627 Ti - Loop Capillary 100 µl ID 0.5 1.08 m lg 01079-87302 Ti - Pump Capillary ID 0.25 70 cm lg 01079-87306 Ti - Valve Metering Capillary ID 0.25 140 mm lg 01079-87301 Ti - Sampling Unit 01079-60001 Ti - Seat Capillary ID 0.17 180 mm lg 01079-87303 Ti - Needle Seat (Peek) 01079-67101 Ti - Capillary 500 µl Volume ID 0.5 2.8 m lg 01079-87307 Ti - Capillary 2 ml Volume ID 0.94 2.8 m lg 01079-87308 Ti - Flush Union 01079-23203 Analytical Head Assembly, includes 01079-60003 Ti- Piston Seal 0905-1199 Ti - Head Body 01079-27710 Ti - Column Capillary ID 0.17 70 cm lg 01079-87305 384 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Parts Information Overall Diagram 79855A/B Overall Diagram 79855A/B Table 92 Overall Diagram Item Description Part Number Item Description Part Number 1 Foot Support 01078-21001 21 Flexible Tubing (12ft) 5021-7127 2 100 Sample Tray 18596L/M 22 Press Switching Cable 01078-61601 3 Tray Support Assembly 01078-64701 23 Nut M4 0535-0056 4 Screw M3.5 6 mm lg 0515-0889 24 Pneumatic Assembly 01078-66101 5 Cover Hinge 01078-44112 25 Screw M4 35 mm lg 0515-1666 6 Screw M3.5 6 mm lg 0515-0889 26 Name Plate 5041-2170 7 Fan Holder 01078-02302 27 Logo Base 5041-2144 8 Fan Assembly 3160-0862 28 Front Panel 01078-60301 29 Inner Cabinet 01078-64401 0515-1918 30 Screw M3.5 8 mm lg 5021-1862 10 Sheet Metal Kit 01078-68701 31 Power Switch Base 5041-2145 11 Screw M3.5 6 mm lg 0515-0889 32 Leak Assembly, includes 33, 34, 35 5062-8551 12 Bumper 0403-0427 36 Sample Tray 01078-44501 13 Foot Front 5041-2161 37 Sample Tray 34 vials 01078-44511 14 Push bottom, white 5041-1203 38 Sampling Unit 01078-60001 15 Actuator 5041-2162 39 Screw M3.5 6 mm lg 0515-0887 16 Spring Compression 1460-1510 40 Flexible Tubing (12ft) 5021-7127 17 Front Plate 5001-3725 41 Connector 0100-1175 18 Leak Sensor 5061-3356 42 Muffler 0100-1176 19 Screw M3 10 mm lg 0515-1105 43 Adapter 79846-23202 20 Leak Tub 01078-44502 44 Connector, long 0100-1047 Fan Upgrade Kit (for ALS without 01078-68720 fan) 9 Screw M4 20 mm lg (special) Service Handbook for 1050 Series of HPLC Modules - 11/2001 385 Sampler: Parts Information Overall Diagram 79855A/B Table 92 Overall Diagram Item Description Part Number Item Description Part Number 45 Valve Metering Capillary ID 0.25 140 mm lg 01078-87301 59 Screw M4 6 mm lg 0515-0898 46 Top Cover 01078-04110 60 Analytical Head Assembly 01078-60003 47 Loop Capillary 100 µl ID 0.5 1.08 m lg 01078-87302 61 Metering Drive 01078-60002 48 DPS-B 5061-3374 62 Cable; FIP to ALM 5061-3400 49 Plate Cover P/S 5001-3728 63 HPS Valve Exchange 01078-60004 01078-69004 50 MTD Board (18596A/L) Exchange 01078-66503 01078-69503 64 Valve Waste Capillary ID 0.5 130 mm lg 01078-87304 50 MTD Board (18596B/M) Exchange 01078-66513 01078-69513 65 Screw M4 6 mm lg 0515-1963 51 Cover large (3 inch) 01078-04115 66 Screw M5 6 mm lg 0515-1117 52 FIM Board 01078-66506 67 Valve Base Plate part of (10) 53 Screw M3 6 mm lg 0515-0912 68 Valve Holder Plate 01078-02310 54 VMD Board Exchange 01078-66501 01078-69501 69 Card Cage part of (10) 55 NMD Board Exchange 01078-66502 01078-69502 70 Keyboard Module 01078-60201 56 Cover small (1.3 inch) 5001-3721 71 Fluorescent Interface 5061-3376 57 CMP Board Exchange 5061-3380 01050-69580 72 ALM 01078-66504 58 Screw M5 10 mm lg 0515-1117 386 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Parts Information Overall Diagram 79855A/B Figure 135 Overall Diagram Part 1 Service Handbook for 1050 Series of HPLC Modules - 11/2001 387 Sampler: Parts Information Overall Diagram 79855A/B Figure 136 Overall Diagram Part 2 388 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Parts Information Hydraulic Flow Path Hydraulic Flow Path Table 93 Hydraulic Flow Path Autosampler Item Description Part Nmber Item Description 6 Multi Draw Kit, includes Part Nmber 1 Pump Capillary ID 0.25 70 cm lg 01078-87306 1 Ti - Pump Capillary ID 0.25 70 cm lg 01079-87306 500 µl Volume ID 0.5 2.8 m lg 01078-87307 2 Valve Metering Capillary ID 0.25 140 mm lg 01078-87301 2 ml Volume ID 0.94 3.1 m lg 01078-87308 2 Ti - Valve Metering Capillary ID 0.25 140 mm lg 01079-87301 Flush Union 79846-23203 3 Loop Capillary 100 µl ID 0.5 1.08 m lg 01078-87302 6 Ti - Multi Draw Kit, incudes 01079-68704 3 Ti - Loop Capillary 100 µl ID 0.5 1.08 m lg 01079-87302 Ti - Capillary 500 µl Volume ID 0.5 2.8 m lg 01079-87307 4 ZDV Fitting 0100-0900 Ti - Capillary 2 ml Volume ID 0.94 2.8 m lg 01079-87308 4 Ti - ZDV Fitting 5021-1871 Ti - Flush Union 01079-23203 5 Needle (fitting laser welded) 01078-67200 5 Ti - Needle 01079-67201 7 Column Capillary ID 0.17 80 cm lg 01078-87305 5 Needle Grooved 01078-67202 7 Ti - Column Capillary ID 0.17 70 cm lg 01079-87305 6 Seat Capillary ID 0.17 180 mm lg 01078-87303 8 Valve Waste Capillary ID 0.5 130 mm lg 01078-87304 6 Ti - Seat Capillary ID 0.17 180 mm lg 01079-87303 Service Handbook for 1050 Series of HPLC Modules - 11/2001 01078-68704 389 Sampler: Parts Information Hydraulic Flow Path Figure 137 Solvent Flow Path 390 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Parts Information Sampling Unit Sampling Unit Table 94 Sampling Unit Item Description Part Nmber Item Description Part Nmber Complete Assembly 01078-60001 18 Lubrication Ring 5001-3749 Complete Ti - Assembly 01079-60001 19 Coupler Assembly 01078-63201 1 Tray Motor Assembly 01078-64702 20 Plug Hole 6960-0076 2 Screw M3 12 mm lg 0515-1110 21 Motor Coupler 1500-0796 3 Washer 3050-0890 22 Set Screw M5 10 mm lg 0515-1741 4 Screw M2.5 6 mm lg 0515-0894 23 Belt 1500-0698 5 BOS Board 01078-66505 24 Belt Roller 01078-22501 6 Screw M3.5 6 mm lg (older version) 0515-0887 25 Bearing Sleeve 1410-1253 6 Screw M3.0 6 mm lg 0515-0886 26 Washer 3050-0891 7 Washer 3050-0892 27 Screw M3 25 mm lg 0515-1060 8 Cable Clamp 1400-0082 28 Needle Seat 79846-67101 9 Retaining Ring 0510-1310 28 Ti - Needle Seat (Peek) 01079-67101 10 Washer Spring 3050-1299 29 Seat Capillary ID 0.17 180 mm lg 01078-87303 11 Bearing Sleeve 1410-1261 29 Ti - Seat Capillary ID 0.17 180 mm lg 01079-87303 12 Sampler Body no PN 30 Socket 01078-25201 13 Screw M2.5 6 mm lg 0515-0894 31 Shock Mount 1520-0260 14 Washer 3050-0890 32 Screw M3 6 mm lg 0515-0886 15 Home Sensor 5180-0861 33 Spindle Motor Assembly 01078-64703 16 Traction Relief 5001-3752 34 Spring 1460-2365 17 Tray Coupler 01078-43201 35 Needle Arm Assembly 01078-60000 Service Handbook for 1050 Series of HPLC Modules - 11/2001 391 Sampler: Parts Information Sampling Unit Table 94 Sampling Unit Item Description Part Nmber Item Description Part Nmber 36 Washer 3050-0890 43 Ti - ZDV-Fitting 5021-1871 37 Screw M2.5 6 mm lg 0515-0894 44 Needle (fitting laser welded) 01078-67200 38 Interrupter Sensor 5041-2142 45 Connector Cable 01078-61602 39 Cable Clamp 1400-0082 46 Traction Relief 5001-3752 40 Washer 3050-0892 47 Quadrature Encoder 1990-1265 41 Screw M3.5 6 mm lg (old version) 0515-0887 48 Screw M2.5 25 mm lg 0515-1640 41 Screw M3.0 6 mm lg 49 Screw M3.5 6 mm lg (older version) 0515-0887 42 Needle (old design) 49 Screw M3.0 6 mm lg 0515-0886 42 Ti - Needle 01079-67201 50 Gear Cover 01078-04101 43 ZDV-Fitting 0100-0900 51 Bumper Foott 0403-0282 392 0515-0886 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Parts Information Sampling Unit Figure 138 Sampling Unit I Service Handbook for 1050 Series of HPLC Modules - 11/2001 393 Sampler: Parts Information Sampling Unit Figure 139 Sampling Unit II 394 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Parts Information Sampling Unit Arm Assembly Spare Parts Table 95 Arm Assembly Spare Parts Item Description Part Nmber Arm Spare Part Kit Item Description Part Nmber 01078-68706 3 Bottle Vane no PN 1 Bottle Vane Screw no PN 4 Clamp Plate no PN 2 Screw M3.5 10 mm lg no PN Figure 140 Arm Assembly Spare Parts Service Handbook for 1050 Series of HPLC Modules - 11/2001 395 Sampler: Parts Information Metering Drive and Analytical Head Metering Drive and Analytical Head Metering Drive Table 96 Metering Drive Item Description Part Nmber Metering Drive Assembly Item Description Part Nmber 01078-60002 3 Interrupter Sensor 5041-2142 1 Metering Motor no PN 4 Screw M2.5 6 mm lg 0515-0894 2 Belt 1500-0697 5 Washer 3050-0890 Analytical Head (Old Version) Table 97 Analytical Head (old version) Item Description Part Nmber Item Description Part Nmber Analytical Head Assembly 01078-60003 11 Seal Keeper order (10a) Ti - Analytical Head Assembly 01079-60003 12 Seal (2/pk) 5062-8516 6 Spring Support no PN 12 Ti-Seal 0905-1199 7 Sapphire Plunger 5063-6586 13 Head Body 01078-27710 8 Spring 1460-2220 13 Ti - Head Body 01079-27710 9 Adapter see new version 14 Screw M4 40 mm lg 0515-0850 order (10a) 15 Set Screw M3 5 mm lg 0515-1039 5001-3739 16 Screw M5 60 mm lg 0515-2118 10 Support Ring 10a Support Seal Assembly 396 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Parts Information Metering Drive and Analytical Head Figure 141 Metering Drive and Analytical Head (old version) Service Handbook for 1050 Series of HPLC Modules - 11/2001 397 Sampler: Parts Information Metering Drive and Analytical Head Analytical Head (New Version) Table 98 Analytical Head (new version) Item Description Part Number Item Description Part Number Analytical Head Assembly 01078-60003 5 Seal (2/pk) 5062-8516 Ti - Analytical Head Assembly 01079-60003 5 Ti-Seal 0905-1199 1 Sapphire Plunger 5063-6586 6 Head Body 01078-27710 2 Screw M4 40 mm lg 0515-0850 6 Ti - Head Body 01079-27710 3 Adapter with spring 01078-23202 7 Screw M5 60 mm lg 0515-2118 4 Support Seal Assembly 5001-3739 Figure 142 Analytical Head (new version) 398 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Parts Information High Pressure Switching Valve High Pressure Switching Valve Table 99 High Pressure Switching Valve Item Description Part Number Item Description Part Number High Pressure Switching Valve Assembly 01078-60004 7 Valve Sensor Board 79846-66504 Exchange Assembly excluding items 11 to 17 01078-69004 8 Bracket Actuator 79846-01206 Ti - New Assembly 01079-60004 9 Screw M5 6 mm lg 0515-1510 Exchange Assembly excluding items 11 to 17 01079-69004 10 Elbow Fitting 0100-1408 0101-0626 11 Valve Waste Capillary ID 0.5 130 mm lg 01078-87304 0101-0627 12 Valve Holder Plate 01078-02310 2 Stator 1535-4044 13 Valve Base Plate part of 01078-68701 3 Isolation Seal 1535-4046 14 Screw M5 6 mm lg 0515-1510 4 Stator Screw 1535-4857 15 Screw M4 6 mm lg (flat head) 0515-1963 5 Stator Set Screw no PN 16 Screw M3.5 8 mm lg 0515-1105 6 Bearing Ring 1535-4045 17 Screw M2.5 6 mm lg 0515-0894 1 Rotor Seal VESPEL Ti - Rotor Seal TEFZEL pH 12.5 Service Handbook for 1050 Series of HPLC Modules - 11/2001 399 Sampler: Parts Information High Pressure Switching Valve Figure 143 High Pressure Switching Valve 400 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Parts Information Pneumatic Valve Assembly Pneumatic Valve Assembly Table 100 Pneumatic Assembly Item Description Part Nmber Complete Assembly excluding items 5, 6 and 7 Item Description Part Nmber 01078-66101 4 Elbow Fitting 0100-1408 1 Solenoid Valve 0101-0559 5 Screw M4 35 mm lg 0515-1666 2 Low Air Pressure Switch 1/8” 3107-0019 6 Nut M4 0535-0056 3 Push-in Fitting Male 0100-1410 7 Pressure Switch Cable 01078-61601 Figure 144 Pneumatic Valve Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 401 Sampler: Parts Information Pneumatic Valve Assembly 402 Service Handbook for 1050 Series of HPLC Modules - 11/2001 17 17 Sampler: Additional Information This chapter provides additional information about the 1050 Autosampler Sampler: Additional Information This section gives the following informations: • Autosampler Prefix History • Autosampler Firmware History • Update to Firmware Revision 4.0 • Adding the 100 vial tray • Intermittant E17 • Update the autosampler with a fan 404 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Additional Information Product History Product History Since introduction of the 1050 Autosampler in 1988 a couple of hardware and firmware changes have been implemented into the production. With most of this changes the serial number prefix has been changed too. Following is a list of all prefix changes done in Waldbronn and Little Falls. Table 101 Product History 79855A/B S/N Prefix Changes 2813 G ... 28XX A ... Introduction of the 1050 Autosampler 2848 G ... 2902 A ... Introduction of firmware revision 2.0 2934 G ... 2941 A ... Introduction of firmware revision 2.1 2944 G ... 2950 A ... #024 (add 100 vial capacity) for support of 18596B/M tray 3020 G ... 30XX A ... Fan Assembly added to the autosampler 3031 G ... 30XX A ... Introduction of 1050 Ti Autosampler 3031 G ... 3033 A ... Introduction of firmware revision 3.1 3117 G ... 3121 A ... Introduction of firmware revision 4.0 3130 G ... 3130 A ... Support Ring for Analytical Head with Ceramic Insert 3141 G ... 3141 A ... Introduction of firmware revision 4.1 3313 G ... 3315 A ... New Revision of High Pressure Switching Valve 3313 G 02712 or 3315 A 02247 Modification of ALM board to increase fan voltage 3334 G ... Introduction of support seal assembly 3338 G ... Introduction of firmware rev. 4.2 3404 G ... 3406 A ... Analytical Head - Spring integrated in the adapter May 1995 Needle with integrated Fitting October 1998 Adapter (Analytical Head) with new spring 3442 G ... 3443 A ... Sampling Unit - ZDV Fitting Laser welded to the Needle Service Handbook for 1050 Series of HPLC Modules - 11/2001 405 Sampler: Additional Information Firmware Revisions Firmware Revisions Firmware Revision 1.0 Rev 1.0 was the firmware at introduction of the 79855A Autosampler. Known Problem: Time table execution Problem is in the timetable execution, if there is more then one entry in the timetable. Manually stop of the run (before elapsing the stoptime) may lead to wrong behavior of the relay contacts in the next run. Workaround/Solution 1 To stop a run manually reduce the stoptime to a value lower then the actual run time. 2 Other 1050 modules do not show this problem and can be used as an alternative to control the relay contacts. Firmware Revision 2.0 Europe/ICON 2848 G ..... US/Canada 2902 A ..... Firmware revision 2.0 incorporates: • Support of 18596A/L sample tray. • Configuration of BCD output (either 2 digit BCD or 8 bit binary coded) • Draw Offset Position for the needle. • Fix of revision 1.0 bug. 406 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Additional Information Firmware Revisions Firmware Revision 2.1 Europe/ICON 2934 G ..... US/Canada 2941 A ..... Revision 2.1 incorporates: • Support of 18596B/M sample tray (Killer Bee). N OT E The 18596B/M sample tray is not compatible to the 18596A/L tray. It does requires a change in firmware and hardware (MTD board). Nevertheless firmware revision 2.1 support both versions of the tray. Known Problem: Intermittant BUS ADDRESS ERRORS Intermittant BUS ADDRESS ERRORS or similar lock ups of the autosampler may occur when the 100 vial tray is connected. A firmware bug in combination with a weak air supply genereates the problem. During the injection cycle a underpressure condition may be detected. This condition might be misinterpreted and then leads to the error. Service Handbook for 1050 Series of HPLC Modules - 11/2001 407 Sampler: Additional Information Firmware Revisions Firmware Revision 3.0 Europe/ICON 3020 G ..... US/Canada 3019 A ..... Revision 3.0 incorporates: • Communication with the HPIB communication interfaces. • Support of the Roto Reader of the 18596A/B tray. • Support of the 34 vial tray in the autosampler. • Introduces the AUTO-ON feature. Known Problems ❏ Serious Problem with 21 vial tray. If the 21 vial tray is not in home position at the begin of an injection, the tray will be recognized as 34 vial tray and positioned accordingly. Damage of the needle can be the result. Any time the 21 vial tray has been moved or replaced, perform a RESET INJECTOR prior to starting an injection. ❏ Reset during injection Break. If the injection cycle is interrupted (injection break-stop during injection) and followed by a RESET INJECTOR hardware crashes may appear. It was observed that either the syringe piston was forced into the mechanical stop or the tray was moved against the needle arm. Swtching off and on the autosampler will cure the problem. Do not use the RESET INJECTOR during injection break. ❏ Teach Mode If one of the possible teach modes (tray or bar code reader) is done without a vial in position 101 the autosampler is forced into an error mode. The error LED is blinking and the display shows the value 3000. ESCAPE and RESET INJECTOR brings the autosampler back into the normal operation mode. 408 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Additional Information Firmware Revisions Firmware Revision 3.1 Europe/ICON 3031 G ..... US/Canada 3033 A ..... The final tests for the DOS workstation revealed some firmware bugs in the autosampler firmware. Revision 3.1 fixes these communication bugs. Known Problems ❏ Problems with Relay Contact 2. Relay Contact 2 generates a double pulse each time it is turned on or off. ❏ Intermittant E26, E32, E33 or E34: 100 vial tray arm moves two vials into position #16 of the 21 vial tray. A firmware bug in the synchronization between the autosampler and the 100 vial tray generates the problem. The firmware expects that the metering syringe is already in home position before the 100 vial tray places its vial into the 21 vial tray. With large injection volumes (for example100 µl) and lower eject speed (for example <200 µl) the initialization of the syringe takes longer then the movement of the tray arm. Set the EJECT SPEED to at least 300 when using larger injection volumes. Service Handbook for 1050 Series of HPLC Modules - 11/2001 409 Sampler: Additional Information Firmware Revisions Firmware Revision 4.0 Europe/ICON 3117 G ..... US/Canada 3121 A ..... Revision 4.0 incorporates: • Support of Injector Program. • Introduction of additional displays. • Changes in tray movement. • Addition of error messages. • Fixes of known bugs. N OT E Autosamplers with serial number prefix below 3117 G ..... and 3121 A ..... need a modification of the NMD board when updated to revision 4.0. A capacitor (100 pF part number 0160-4801) has to be soldered between pin 5 and 7 of U26 on the NMD board. Known Problems ❏ Incorrect BCD output for vials in 100 vial tray. When working from the 100 vial tray the transfer position is always used as output for the BCD output. Therefore the bottle number displayed on the integrator is always 16 for BCD, or 10 for BIN, if the bottle number is transfered via a BCD cable. PHOENIX and LC APPAC do not show the problem. ❏ Using the injector program feature allows a work around for the problem. {{ 10 DRAW def µl from SMPL SPEED def µl/min OFFSET def mm}} {{ 20 UTILITY OUTPUT SMPL }} ❏ Intermittant hang-up of a sequence that uses overlap and return mode for the 100 vial tray. ❏ Adjustment of the sampling unit home (hall) sensor via the service only is not possible. INSTR# 4 gives incorrect values. 410 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Additional Information Firmware Revisions Firmware Revision 4.1 Europe/ICON 3141 G ..... US/Canada 3141 A ..... Revision 4.1 incooperates: • Fix of the three known bugs of revision 4.0 • The default transfer position is redifined (better position). • The utility ’tray move’ command of the injector program allows to use the sample vial option now. • The wait after a post time represents a seperate event (for future workstation only). • Keep/Return configuration changes during the injection are possible now. Firmware Revision 4.2 The following two bugs in the revison 4.1 firmware have been fixed with revision 4.2. • The LC ChemStation could not access all Injector Program features. The bar code reader did not function in this mode. • Autosampler with 100 vial tray in KEEP mode show a malfunction when a injection >1 is interrupted (STOP during the injection cycle) and then aborted. The inject LED remains on and a new START command will result in a "Not Ready Wait 0.00" display and no injection will take place. Service Handbook for 1050 Series of HPLC Modules - 11/2001 411 Sampler: Additional Information Firmware Revisions If you update the firmware to revision 4.0 and greater Firmware revision 4.0 requires a modification of the NMD board otherwise incorrect positioning of the 21/34 vial tray may appear. The new firmware revealed an already existing problem of the NMD board. Noise on a signal line which is used more often then in previous firmware versions might lead to incorrect data words for the 21/34 vial tray. A 100 pF capacitor (part number 0160-4801) soldered between pin 5 and 7 of U26 on the NMD board cures the problem. All autosampler with serial number prefix 3117 G ... and 3121 A ... do have the capacitor already installed. If you add a 100 vial tray to the autosampler The update for the additional 100 vial tray comprises an option or upgrade kit for the autosampler, which consists of bracket, electronic controler board and firmware (if required) and the unmodified GC tray 18596. Currently there are two 100 vial trays in the field, the 18596A and the HP 18596B. Looking the same from the outside they differ and are not compatible. Different electronic boards (MTD) are neccessary to control the two trays. The basic difference is the controller firmware on the MTD board. Table 102 Compatibility Table 18596A/L 18596B/M Firmware 2.0 or higher 2.1 or higher SN Prefix 2848 G / 2902A 2944 G / 2950 A MTD Board 01078-66503 / -69503 01078-66513 / -69513 MTD firmware (U33) 412 18594-80295 Service Handbook for 1050 Series of HPLC Modules - 11/2001 Sampler: Additional Information Firmware Revisions If you have Intermittant E17: Needle cannot move out of vial Variations in the size of the vial ground might be the source of the problem. If the needle touches the ground during the injection cycle the error might appear. If the down movement of the needle is stopped by the vial ground it may happen that the interrupter sensor gets activated. This indicates that the needle is in the home position (seat). The up movement of the needle is prohibited when the interrupter sensor is activated and results in the error message. Using the draw offset command for the needle will solve the problem. All firmware revisions 3.1 and below may show this problem. Revision 4.0 and greater do not show the problem because of the changes done for the injector program. If you have to update the autosampler with a fan In August 1990 a fan was added to the autosampler (see also “Product History” on page 405). It cools down the electronic boards and prevents an increase of the electronical failure rate when the card cage is equipped with one or more additional option boards (for example MTD board, RRC board or CIB board). All autosampler equipped with the 100 vial tray (MTD RRC) or/and the HPIB board (CIB) should be updated with the fan. The fan upgrade kit 01078-68720 allows to retrofit autosampler without fan. If the fan in the autosampler does not work properly There is a possible problem with the fan in the 1050 Autosampler. It has been realized that the fan does not start in all cases when the autosampler is switched on. Measurements showed that the voltage at the fan can drop below the needed +12V during the turn on cycle of the fan. Depending on the quality of the fan (batch related) it will not start in any case. All autosampler with serial number prefix 3313 G 02712 or 3315 A 02247 have the voltage for the fan increased by changing R1 on the motherboard (ALM) from 100 Ohm 2 Watt to 33.2 Ohm 0.5 Watt (0757-0995). N OT E The noise of the fan will be slightly increased by this modification. Service Handbook for 1050 Series of HPLC Modules - 11/2001 413 Sampler: Additional Information Firmware Revisions Update of existing Autosampler Check wether the fan of the autosampler is running or not. Make also sure that the fan will start at turn on of the module. If not, replace R1 on the motherboard with the 33.2 Ohm resistor. ❏ Identify R1 which is located next to the connector J8 for the keyboard cable. ❏ Cut the wires of the 100 Ohm resistor close to its body. This allows you to solder the new 33.2 Ohm resistor (0757-0995) to the existing wires without removing the ALM board from the card cage. If the needle lifts the vial out of the tray When the needle is raised out of the vial during an injection, cycle it may happen that the vial is lifted out of its position (but finally drops back into the tray). The reason might be a too weak spring in the bottle in place sensor assembly. This happens only, if the septa is very tight. All autosamplers with serial number prefix 3313 G... have a stronger spring 1460-2365 installed. The new spring is much stronger then the old one and will keep the vial in place also with tight septa. If the injections are not reproducible (grooved needle) It has been reported that a couple of customers had reproducibilty problems when injecting larger volumes from vials that have been crimped very tight. For such cases a grooved needle has been set up. 414 Service Handbook for 1050 Series of HPLC Modules - 11/2001 In This Book This manual contains technical information about the Agilent 1050 liquid chromatographs. This manual is available as electronic version (Adobe Acrobat Reader file) only. 1050 Series of HPLC Modules Service Handbook Diode Array Detector (G1306A) and Multiple Wavelength Detector (79854A) Copyright Agilent Technologies 2001 All rights reserved. Reproduction, adaption, or translation without prior written permission is prohibited, except as allowed under the copyright laws. Part No. NONE 11/2001 Printed in Germany Warranty IMPORTANT NOTE The information contained in this document is subject to change without notice. This version of the 1050 service manual includes all sections from the 01050-90102 edition 4 (1995) and G1306-90102 edition 2 (May 1994). It merges both sections, the MWD and the DAD. Agilent Technologies makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties or merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Agilent Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn Germany The series I opticals information (79854A MWD) information has been removed (product went out of support during 2000). Part numbers have been updated as of 11/2001. Contact your local Agilent support office in case of part number issues or upgrades. The latest version of this manual is available as Adobe Acrobat Reader (PDF) version only and can be downloaded from the Agilent Technolgies web page www.agilent.com. 18 18 DAD/MWD: General Information This chapter provides general information about the 1050 Diode Array and Multiple Wavelength Detectors DAD/MWD: General Information This chapter gives general information on • about this detector • repair policy • features • user-interfaces • specifications About the Detector General The 1050 Diode Array Detector (G1306A DAD) and Multiple Wavelength Detector (79854A MWD) module houses the optical system and the electronic circuitry which acquire and process absorbance data. Control of optics (radiation source shutter photo diode array etc.) is an integral part of the electronics. The module is controlled through the user interface through which the operator defines his requirements (detection parameters etc.) and through which the system presents the required analytical information. Repair Policy The 1050 DAD/MWD is designed that you can access all components easily. Customers are able to repair certain parts of the 1050 DAD/MWD described in the User Handbooks. For details on repair policy refer to “Repair Policy” on page 38 in chapter 1050 Common Information. 420 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: General Information About the Detector Identification The module is identified by a 5 digit product number (G1306A or 79854A) and a 10 unit serial number on a label attached to the wall inside the module. The first four digits of the serial number are the serial prefix. The letter identifies the country of origin. The last five digits are an identification number unique to each module. Any changes to the modules will be covered initially by Service Notes. They will be sent out to all Service personnel prior to implementation of the change to the instrument. With every reprint these changes will be incorporated into the service documentation. Compatibility The replacement parts of the 1050 MWD are usable in the 1050 DAD and vice versa. The 1050 MWD can be upgraded to a 1050 DAD. Service Handbook for 1050 Series of HPLC Modules - 11/2001 421 DAD/MWD: General Information DAD Differences DAD Differences The G1306A Diode Array Detector (DAD) is basically the 1050 Multiple Wavelength Detector (MWD). The DAD has the same hardware as the 1050 MWD with two exceptions: keyboard and firmware are different. • The 1050 DAD is NO replacement for the 1050 MWD. • The 1050 DAD adds spectra capabilities to the existing 1050 MWD, necessary for workstation controlled 3D detection systems. • The 1050 DAD needs control by the HPLC DOS ChemStation (PHOENIX 3D-PLUS) to become operable. • Upgrade from 1050 MWD to 1050 DAD will need new firmware and a new user interface (keyboard). Added features The following features are new (compared to the 1050 MWD): • up to five independent signals (sample and reference wavelength each) • up to 5 spectra/second (time programmed, periodically or peak controlled) • temporary storage of up to 90 spectra in internal run buffer • up to 1 spectrum/second for monitor output • lamp-on time information Removed features from local keyboard The following features are removed from local keyboard access (compared to the 1050 MWD). The functionality is covered by the workstation: • reduced run buffer size for signal data (shared between signal and spectra) • no local spectra evaluation (e.g. spectra plot to analog output and spectrum maximum calculations). This also affects the diagnostic functions holmium test and intensity profile plots. • No signal arithmetic for the analog outputs. Signal A is analog output 1 and signal B is analog output 2. 422 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: General Information DAD Differences The signal multiplication factor has been removed from signal parameter set points. • no max monitor screen. Restrictions of user interface The user interface does have the following restrictions: • no access to method parameter including the time table (e.g. signal settings, external contacts). • no method storage functionality (includes ’on error method’). • no access to time-out or auto-on function. • DATE&TIME will be monitored but cannot be set locally. • no parameter lock on/off. • no settings of the analog output functions and offsets. Compatibility The replacement parts of the 1050 MWD are usable in the 1050 DAD and vice versa. The 1050 MWD can be upgraded to a 1050 DAD. An upgrade kit will contain the necessary hardware and instructions (see section Parts Identification). The 1050 DAD cannot be operated properly in an integrator based system. The LC APPACK software will not recognize the 1050 DAD as a module to control. Service Handbook for 1050 Series of HPLC Modules - 11/2001 423 DAD/MWD: General Information DAD Differences Local User Interface The keyboard of the user interface has been changed. A different keypad foil shows a limited number of available keys (see Figure 145 on page 424). Figure 145 Local User Interface 424 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: General Information DAD Differences The following functions remain the same as for the 79854A MWD (same keys): • LAMP ON/OFF Pressing NEXT LAMP ON FOR n hours and RESET LAMPHOURS (enter)are displayed. • BALANCE • START and STOP • Status line including signal A monitor, not ready conditions, logbook, installed options and firmware revisions. The following functions are hidden behind the STATUS key for maintenance purpose): • DATE&TIME • REVISION • CONFIGURATION ❏ remote configuration. ❏ set GPIB address. ❏ autobalance on/off. ❏ lamp current setting. ❏ set wavelength calibration factor. ❏ set analog output voltage. • TEST FUNCTIONS ❏ measure intensity. ❏ Holmium spectrum. ❏ lamp intensity. ❏ gain (ASC). ❏ D/A converter. ❏ electronics noise. ❏ shutter position. ❏ wavelength calibration check. Service Handbook for 1050 Series of HPLC Modules - 11/2001 425 DAD/MWD: General Information DAD Differences Workstation Interface The 1050 DAD must be operated with the LC ChemStation. Rawdata File The run buffer within the detector is shared by signal and spectra data. In case the run buffer is going to overflow, the signal data will have the higher priority: the last stored spectrum is removed from the run buffer. This will guarantee useful signal data but may cause loss of interesting spectral data. The run buffer can hold up to 30000 signal data points or about 90 spectra. Peak Detector The peak detector (PD) always uses signal A as the ’pilot’ signal. The PD is adjusted by means of the two set points peak width and threshold. Both setpoint are time programmable. Whereas the PD-threshold is a method parameter of its own, the PD-peak width parameter is derived from the general peak width (PKWD) parameter. At start of the run the value for the PD-peak width is set equal to the PKWD setpoint. During the run the PD-peak width parameter can be changed by time programming. Spectra Acquisition Modes The spectra acquisition mode allows automatic storage of spectra during a run. The mode can be changed during the run by time programming. Compared to the 1040 DAD the 1050 DAD will have two new features • storing spectra at the baseline before the begin of a peak • periodically store spectra during a peak and at a reduced data rate. The modes in detail are: 426 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: General Information DAD Differences Table 103 Spectra Acquisition Modes Mode Details none no spectra is stored apex top of peak spectra is stored apex + baselines last baseline spectrum before peak, top of peak spectrum and first baseline spectrum after peak is stored. apex + slopes spectrum in peak upslope, at top of peak and in peak downslope is stored. apex + slopes + baselines combined apex + slopes and apex + baselines. all in peak compared to storing all spectra periodically, only stores spectra within a peak at doubled period. Starts with last baseline spectrum before peak and ends with first baseline spectrum after peak. If baseline spectra are not detected, the spectrum before the first spectrum in peak or the spectrum after the last spectrum within the peak is stored instead. all periodically all spectra are stored. The period depends on the peak width setting. For peak width setting=0 (narrowest peak), the spectrum data rate would be 20 Hz Service Handbook for 1050 Series of HPLC Modules - 11/2001 427 DAD/MWD: General Information DAD Differences Test Functions The 1050 DAD has a reduced user interface and no analog output (DAC board is optional). It has no means to display (plot) the spectra (or intensity scans) of some of the built-in tests. These plots can be retrieved with the Workstation. Options Because the 1050 DAD is only operable together with the workstation, the Communication Interface Board (CRB) is mandatory. Because the 1050 DAD typically needs no analog output signals, the Digital to Analog Conversion Board (DAC) is optional. For complete description of test conditions used to obtain specifications, see Owner’s manual. 428 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: General Information Specifications DAD/MWD Specifications DAD/MWD Table 104 Specification of the 1050 DAD/MWD (Series II Optical) Detection Type Double beam photometer Signals Up to 3 (MWD) or 5 (DAD), each defined by a sample wavelength and bandwidth and an optional reference wavelength and bandwidth. Signal Combinations Sum of two signals; difference of two signals; ratio of two signals, with definable range and threshold; window plot with definable ratio, range and threshold. Noise < ±2.0 x 10-5 AU peak-to-peak, at 254 nm with 4 nm bandwidth, flowing water at 1 ml/min, 1 second response time (10-90%). Drift < 2 x 10-3 AU/hour, at 254 nm, after warm-up. Wavelength Range 190-600 nm, selectable in 1 nm increments. Bandwidth Range 2-400 nm, selectable in 1 nm increments. Wavelength Accuracy ±1 nm. Linear Absorbance Range Better than 1% up to 1.5 AU, using acetone at 265 nm. Response Time 8 choices, ranging from 0.1 to 20 seconds (10-90%). Spectra Storage of at least 8 spectra, with definable wavelength range from 190-600 nm (total number of spectra depends on range defined). Post-run plotting of original or subtracted spectra possible. Spectra Resolution depends on slit width. Absorbance Resolution < 5 x 10-6 AU Spectra Acquisition 12.5 ms from 190 to 600 nm; according to the response time settings scans are accumulated for one data point for improved sensitivity. Service Handbook for 1050 Series of HPLC Modules - 11/2001 429 DAD/MWD: General Information Specifications DAD/MWD Table 104 Specification of the 1050 DAD/MWD (Series II Optical) Light Source Deuterium lamp. Flow Cell (Series II) SST cell, 8 µl volume with 6 mm path length or 13 µl volume with 10 mm path length and 120 bar (1760 psi) maximum pressure. Optional high-pressure cells (400 bar). Display 2 line by 16 character fluorescent display with real-time display of operating parameters or absorbance and wavelength of maximum absorbance. Control Integrated keyboard with function keys; parameter editing during run possible; keyboard lock. External control via GPIB with ChemStation or RS-232. Integrated keyboard with function keys; limited functionality and control on DAD. Parameters Signal definitions (wavelengths/bandwidths), attenuation, response time, zero offset, balance; spectra definitions; external contacts; analog outputs. Time-programmable Parameters Wavelengths/bandwidths, attenuation, spectra acquisition, external contacts. Methods Battery-backed storage of up to ten methods (depends on length of method), including initial and time-programmed parameters. Automatic startup and shutdown methods. Editing of stored methods possible during run. Analog Outputs Two analog outputs are available (on DAD optional) for output of signals and/or signal combinations; both 1 V/2 AU or 100 mV/2 AU, user-selectable. Communications START (in- and output), STOP (in- and output), READY (output), SHUTDOWN (output) for synchronization with other LC modules; two external contacts including: 1 relay with 24 V and 250 mA; 1 contact closure with maximum 30 V and 250 mA. 430 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: General Information Specifications DAD/MWD Table 104 Specification of the 1050 DAD/MWD (Series II Optical) Safety Aids Extensive diagnostics, error detection and display via front-panel LED’s and status logbook. User-definable shutdown method activated in case of error. Leak detection, safe leak handling, leak output signal to shutdown the pump. Environment Temperature range: 5 to 55 °C Humidity: < 85% (non-condensing) Power Requirements Line voltage: 100-120 or 220-240 VAC ±10% Line frequency: 48-66 Hz Power consumption: 150 VA max. Dimensions Height: 208 mm (8.2 inch) Width: 325 mm (12.8 inch) Depth: 560 mm (22.0 inch) Weight: 16 kg (35 lb.) For complete description of test conditions used to obtain specifications, see Owner’s manual. Service Handbook for 1050 Series of HPLC Modules - 11/2001 431 DAD/MWD: General Information Specifications DAD/MWD 432 Service Handbook for 1050 Series of HPLC Modules - 11/2001 19 19 DAD/MWD: Hardware Information This chapter provides hardware information about the 050 Diode Array and Multiple Wavelength Detectors DAD/MWD: Hardware Information This chapter gives general and technical information about the hardware components of the 1050 Diode Array and Multiple Wavelength Detectors. • overview about the optical system • overview about the electronics • detector hardware ❏ optical units ❏ flow cells ❏ heat exchanger ❏ lamp ❏ shutter assembly ❏ leak sensor ❏ fans N OT E This chapter describes the Series II optical unit hardware only. 434 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Hardware Information Overview: Optical System Overview: Optical System The light from the deuterium lamp is passing an achromat lens system and is focussed first on the exit of the flow cell. Then it passes a lens and is focussed again on the slit assembly. Due to this separation of flow cell and slit and the availability of flow cells with different path lengths (6 and 10 mm) and slit assemblies with different optical slit width (2, 4, 8 nm), it is now possible to optimize the signal-to-noise and the spectral resolution. The optical unit is optimized for the flow cell with 6 mm path length together with the 4 nm slit assembly. Figure 146 Optical System 1 - deuterium lamp 2 - windows 3 - shutter 4 - achromat 5 - flow cell 6 - slit assembly 7 - lens 8 - grating 9 - array Service Handbook for 1050 Series of HPLC Modules - 11/2001 435 DAD/MWD: Hardware Information Overview: Electronics Overview: Electronics Figure 147 shows a block diagram of the 1050 DAD/MWD. The Common Main Processor (CMP) controls all functions of the module. The CMP communicates with the AQB, controls directly the shutter of the optical unit and the power supply. If a leak is detected inside the optical unit, this leak message is connected to the CMP. The CMP also provides the I/O Remote connections. To the CMP the common main processor BUS is connected which allows the communication with the user interface (keyboard), Digital to Analog Converter (DAC) and GPIB/RS232 interface. The Digital to Analog Converter interface is optional. Because of the structure of the 1050 Series the module specific controller firmware is piggy-back loaded to the Data Acquisition Board (AQB). The AQB controls the Analog to Digital Conversion Board (ASC) and the Photo Diode Array (PDA). 436 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Hardware Information Overview: Electronics Figure 147 Block Diagram 1050 DAD/MWD Service Handbook for 1050 Series of HPLC Modules - 11/2001 437 DAD/MWD: Hardware Information Optical Unit Optical Unit The main areas of the optical unit are: Optical housing same for use in 1050 MWD and 1040/90 DAD (different flow cell, cover and slit). flow cell available as stainless steel (SST) with different path lengths (6/10 mm, 8/13 µl) for high pressure use (120 bar). Additional high-pressure cells (400 bar) are also available. Slit assembly available with optical slit width of 2, 4 and 8 nm slit. LPC board interface between leak sensor/shutter assembly and main electronics. Due to this separation of flow cell and slit and the availability of flow cells with different path lengths and slit assemblies with different optical slit width, it is now possible to optimize the signal-to-noise and the spectral resolution. The optical unit is optimized for the flow cell with 6 mm path length together with the 4 nm slit assembly. Figure 148 Optical Unit 438 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Hardware Information Optical Unit Flow Cell Assemblies The new flow cell design allows the work up to higher pressure and the possibility of maintaining and replacing parts. The flow cells can be disassembled, cleaned or repaired. Figure 149 Flow Cell Table 105 Flow Cell Data STD HP-STD HP-Micro Volume 8 or 13 13 1.7 Path length 6 or 10 10 6 mm Maximum pressure in the cell 120 400 400 bar Inlet capillary id 0.17 0.17 0.12 mm Outlet capillary id 0.17 0.17 0.12 mm recommended pH range C A UT I O N µl >2.3 to 9.5 STD Standard Flow Cell HP-STD High Pressure Cell with 13 µl volume HP-Micro High Pressure Cell with 1.7 µl volume Because the very small inner diameter (0.17 or 0.12 mm) of the inlet capillary only very clean solvents should be used. Service Handbook for 1050 Series of HPLC Modules - 11/2001 439 DAD/MWD: Hardware Information Optical Unit Additional Information of High Pressure Cells Typical applications of the high-pressure flow cells are: • Hyphenated systems (LC-MS) • Super Critical Fluid Chromatography (SFC) • Multi-detector systems • Narrow-bore column applications The main difference between the standard and high-pressure flow cells is the design of the window assemblies. The high-pressure flow cells have a different window screw, window and seal ring, washer, and a different number and orientation of conical disk (bevelled) springs, see Figure 150. The seal rings support and hold the window and at the same time form the high-pressure seal. Figure 150 Cross-section of Window Assembly Washer Windows Washer Conical Disk Springs (see below) Window Screw Detail of Conical Disk Springs Showing Orientation The following materials are in contact with solvents: • Stainless steel (AISI 316) • Quartz • Vespel® (polyamide) Vespel is a registered trademark of DuPont. 440 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Hardware Information Optical Unit Under standard conditions (1 ml/min water flow, 254 nm detection wavelength, 4 nm bandwidth, 1 s response time) the noise of the high-pressure micro flow cell might increase. The high-pressure micro flow cell is supplied with an additional 0.12 mm i.d. capillary, allowing you to bypass the heat exchanger. Slit Assembly The separation of the slit from the flow cell allows to change the slits according the needs to optimize signal-to-noise and spectral resolution. Available slit sizes are 2, 4 and 8 nm. Figure 151 Slit Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 441 DAD/MWD: Hardware Information Optical Unit Deuterium Lamp Assembly The deuterium lamp used in the 1050 DAD is the known lamp from the 1040 Diode Array Detector, the 1050 DAD/MWD and the 1050 Variable Wavelength Detector (79853C). The reduction of energy emission of the lamp (Figure 153 on page 443) is time and wavelength dependent and is significantly higher within the first days and for wavelengths in the ultra violet range compared to the visible range (change in transmission of lamp glass). Usually, the response maximum of the lamp is near 230 nm, but can be shifted to a higher wavelength for an aged lamp. It has no relevance for intensity degradation at other wavelengths. Figure 152 Deuterium Lamp Assembly Two versions were used: • 79880-60002 was the original lamp • 79883-60002 with 20% higher initial energy 442 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Hardware Information Optical Unit Figure 153 Intensity Degradation of Lamp (79883-60002) • Measured wavelength is 230 nm • initial intensity about 20% higher than 79880-60002 • should be used with 2 nm slit initially top prevent overload of photo diodes (if intensity is to high). • decrease in intensity is less with use N OT E The lamp should be replaced only if the following two criteria are both fulfilled: Baseline Noise (with test cell) has increased significantly. Amount of counts of the lamp (with test cell) has decreased to less than 50% of the count record of this same lamp when newly installed). The decision to replace the lamp due to criteria 2 alone is not relevant, because the signal/noise may be still within instrument specifications. Service Handbook for 1050 Series of HPLC Modules - 11/2001 443 DAD/MWD: Hardware Information Optical Unit Heat Exchanger Assembly The MWD may exhibit severe noise under certain solvent and LC conditions. This is most noticeable when Acetonitrile is the mobile phase. Therefore a heat exchanger assembly is installed underneath the optical unit. The outlet capillary of the heat exchanger is mounted at the flow cell and is led then into the inlet of the flow cell connected by a union. The heat exchanger contains 60 cm capillary of 0.17 mm i.d. Pressure drop with water at 1 ml/min approximately 25 bar. Figure 154 Heat Exchanger and Flow Cell 444 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Hardware Information Optical Unit Shutter Assembly The Shutter Assembly is located in the cell compartment of the optical unit. The stepper motor is responsible for moving the shutter into one of three possible positions: 3 Shutter not in light path (normal operation) 4 Shutter in filter mode (a holmium filter is moved into the light), refer to TEST FUNCTIONS, see “Shutter Position” on page 506. 5 Shutter in dark position (no light is coming through the cell; this is necessary for dark current measurements carried out for calibration purposes). Figure 155 Shutter Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 445 DAD/MWD: Hardware Information Optical Unit Leak Sensor Assembly A leak sensor is located just under the cell. Should the cell leak, solvent would cool the leak sensor (self-heating thermistor). The resulting change in resistance, measured by comparators on the CMP board would generate an error message on the CMP board and switch the instrument to STANDBY. A drain is located at the bottom of the cell compartment and is led to the module waste system. Damage to the array compartment is prevented by a window which separates the cell from the array compartment. N OT E In a 1050 System (using remote connections) the leak message will switch off the pump. To switch off non-1050 Modules refer to operating manual. Figure 156 Leak Sensor Assembly 446 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Hardware Information Fans Fans Two DC-fans are located between the optical unit and the motherboard, inserted in a set of foam. The left one provides air for the lamp housing and power supply and the right one provides air for the electronics in the rear. For replacement refer to section Procedures. In May 1994, a protection cover for the left fan (close to the lamp connector) was introduced for safety reasons (not shown in Figure 157). Figure 157 Fans Fan cover not shown Service Handbook for 1050 Series of HPLC Modules - 11/2001 447 DAD/MWD: Hardware Information Fans 448 Service Handbook for 1050 Series of HPLC Modules - 11/2001 20 20 DAD/MWD: Electronic Information This chapter provides electronic information about the 1050 Diode Array and Multiple Wavelength Detectors DAD/MWD: Electronic Information This chapter gives information about the electronic of the 1050 Diode Array and Multiple Wavelength Detectors: • Overview • Array Signal Conversion Board (ASC) • Data Acquisition Board (AQB) • Firmware Board (FIM) • Common Main Processor Board (CMP) • Communication Interface Board (CRB) • Fluorescent Indicator Module (FIP) • Motherboard (LUM) • LPC Board • Power Supply (DPS-A) • Digital to Analog Conversion Board (DAC) N OT E For additional details of the assemblies you may refer to the 1050 Service Handbook, Chapter Common Information. 450 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Overview Overview All electronic boards (except the FIP, behind the keyboard and the LPC, in the optical unit) are located in the rear part of the module and they are connected to the Motherboard (LUM). The rear of the detector is shown in Figure 158 on page 452. In the 1050 DAD the following electronic assemblies are available: Table 106 Electronic Boards Description Part Number Exchange Power Supply (DPS-A) 5061-3375 01050-69375 Common Main Processor (CMP) 5061-3380 01050-69380 Array Signal Conversion (ASC) 01048-66501 Digital/Analog Conversion (DAC) (optional) 01048-66502 Data Acquisition (AQB) 01048-66543 Firmware Board (FIM) for DAD G1306-66524 Firmware Board (FIM) for MWD 01048-66504 Leak/Shutter Interface (LPC) 79883-66509 Motherboard (LUM) 01048-66510 Display Interface Board (FIP) 5061-3376 Communication Interface (CRB) 5062-2482 Service Handbook for 1050 Series of HPLC Modules - 11/2001 451 DAD/MWD: Electronic Information Overview Figure 158 Rear of 1050 DAD/MWD N OT E The DAC board is optional in the 1050 DAD. 452 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Overview The system consists of the Photo Diode Array (PDA) with 211 elements, the Array Front End Board (AFE), the Analog Signal Conversion Board (ASC) and the Acquisition Processor Board (AQB). The PDA detects a spectrum of incident light in the wavelength from 190...600 nm with 2 nm increments. The AFE Board consists of a Readout Amplifier, which transfers the accumulated charge from the diodes and generates the PDA signal. The ASC Board consists of a variable gain amplifier, a 16-bit A/D converter, a microprocessor interface and a control logic to control the PDA, the amplifier and the microprocessor interface. Figure 159 Block Diagram of Electronics Service Handbook for 1050 Series of HPLC Modules - 11/2001 453 DAD/MWD: Electronic Information Array Signal Conversion Board (ASC) Array Signal Conversion Board (ASC) Repair Level: Board Table 107 Part Numbers for ASC Board Item Part Number ASC board 01048-66501 The two main functions of the ASC board are: • providing of control signals for the readout routine of the photo diode array; • analog to digital conversion of the array signal. Photo Diode Array Readout Routine The readout cycle (12.5 ms) is divided into 225 time slots each 55.55 µs. Time Slot Function 0 not used 1 dummy diode, not used 2 Bit 1 of shift register, not used 3...211 information of intensity 212 Bit 213 of shift register, not used 213 dummy diode, not used 214 not used 215 Offset value, Gain = 1 216 Offset value, Gain = 2 217 Offset value, Gain = 4 218...224 not used 454 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Array Signal Conversion Board (ASC) Figure 160 Block Diagram ASC Board Service Handbook for 1050 Series of HPLC Modules - 11/2001 455 DAD/MWD: Electronic Information Array Signal Conversion Board (ASC) The analog ARRAY SIGNAL coming from the AFE board is in the range of -5 V to - 10 V depending on the intensity of the light falling on to the photo diodes. Analog/Digital Conversion The principle of conversion is based on the Triple-Slope technique see Figure 161. During the TRACK phase the integration capacitor is loaded by a constant voltage Uc. This voltage is proportional to the ARRAY SIGNAL voltage. The voltage Uc is in the range of 0...10 V and is present for 12.37 µs. Figure 161 Triple Slope Integration During the HOLD phase (the ARRAY Signal voltage is disconnected). Uc is discharged by two constant bipolar currents I1 and I2 and the discharge time is measured. U c is discharged with I1 until the zero passage is reached. The time used for this down slope is counted with the clock (18.432 MHz) and will represent the upper 9 bits of the 16 bit data word. After the zero passage I1 is switched off with the next active clock and the negative residual charge is discharged with I 2 until the zero passage is reached the second time. The time between both zero passages represent the lower 7 bits of the 16 bit data word. In reality only I 1 is switched and I2 is on permanent to avoid failures due to multiple switching. 456 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Array Signal Conversion Board (ASC) The cycle for the conversion takes 55.55 µs (18 kHz) and is divided into 1024 steps of 54.2 ns (18.432 MHz) which is the internal clock on the board. During steps 0...227 the amplified input voltage (ARRAY SIGNAL) is switched through and the integration capacitor is charged. The gain level can be 1, 2 or 4 depending on the instrument characteristic of the light source. These amplification factors are measured for each diode at the begin of a chromatographic run when a BALANCE is made. The values are put as a table into memory on the AQB Board. Starting with step 228 the input voltage is disconnected from the capacitor and a RESET pulse resets all flip-flops and counters. Current I1 is switched on. The conversion starts. Up to this point the described timing sequence is independent of the input voltage. The following processes are controlled by the zero passages. The 9-bit counter counts the clock pulses until the comparator sees a zero passage of the integrator voltage. Then I1 and the 9-bit counter are switched off. I 2 and a 8-bit counter are now active discharging the negative integrator voltage until the next zero passage. The 8-bit counter stops. During steps 1012...1016 the 16 bit data word is build. The 16 bit word is moved into the output registers from where the AQB Board takes the information. Because of the ‘long’ availability of the data word (55.55 µs) the AQB processor has enough time to get the data. Input Amplifier and Integrator The ARRAY SIGNAL coming from the AFE Board is in the range of +0.1 V (dark) and -5.1 V (bright). A input amplifier transfers this voltage into the range of -0.7 V to -11.1 V which is the input of an amplification switch. This switch changes the amplification factor of the integrator stage (gain factor 1, 2 or 4). The adjustment of the separate photo diodes is done by the AQB Board. Ramp Amplifier and Comparator The ramp amplifier is used to increase the slope speed of the integrator voltage. The comparator looks for the zero passage and provides the signals COMP and COMP- for the time and control logic. Service Handbook for 1050 Series of HPLC Modules - 11/2001 457 DAD/MWD: Electronic Information Array Signal Conversion Board (ASC) DC-Voltages The internal reference voltages +10 V and -10 V are derived from the +15 V. Input voltages: +19 V, -19 V, AGND +5 V, DGND Output Voltages: +15 V, -15 V, AGND +5 V, DGND Digital Sections This section provides all timing and control signals used on the ASC Board. The timing is done with a Programmable Array Logic (PAL) that gets 8 synchronous input signals in the range of 2.304 MHz and 18 KHz all derived out of the 18.432 MHz main clock. A SYNC signal is used for synchronization of the switching power supply. The comparator signals COMP and COMP- (generated in the analog part) control the 9-bit and 8-bit counter. The 16-bit data word is transferred to the Data Acquisition Board (AQB) via the 16-bit Data Register. Status information is transferred to the Data Acquisition Board (AQB) via the Status Register. 458 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Data Acquisition Board (AQB) Data Acquisition Board (AQB) Repair Level: Board and Fuse F11, F12 and Firmware Table 108 Part Numbers for AQB Board Item Part Number also used for AQB Board 01048-66543/-69543 G1600A CE Firmware Board DAD/CE G1306-66524 Firmware Board MWD 01048-66504 Fuse F11, F12 (250 mA) 2110-0004 G1600A CE The Data Acquisition Board (AQB) is the ’personality module’. It contains the firmware for the main processor system. Firmware including address decoder will be located piggy back on the FIM board. But the main purpose of this board is to hold special hardware only necessary for the DAD/MWD. This is frontend control hardware and a data reduction processor system including dual port RAM for data transfer to main processor. Main Functions • max. four EPROM main firmware on FIM board • FIM board piggy back on AQB board • lamp control hardware • stepper motor driver hardware for shutter • 2 external contacts ❏ 2 connectors on rear panel ❏ 1 contact without supply (only contact closure) max. 30 V (fused with 250 mA) ❏ 1 contact with internal 24 V supply (fused with 250 mA) Service Handbook for 1050 Series of HPLC Modules - 11/2001 459 DAD/MWD: Electronic Information Data Acquisition Board (AQB) Figure 162 Block diagram of AQB Board 460 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Data Acquisition Board (AQB) Frontend Processor Area • 6809 running at 2 MHz • A/D converter interface • frontend firmware 512 byte • 8 Kilobyte dual port RAM including interrupt register Main Processor Area • max. four EPROM main firmware on FIM board • FIM board piggy back on AQB board • lamp control hardware ❏ lamp on/off (anode voltage) ❏ heater on/off ❏ lamp start (600 V ignition) ❏ 2 lines for lamp current select status • stepper motor driver hardware for light shutter ❏ motor on/off ❏ 4 bit step pattern lines • bus buffer for backplane bus connection • 2 external contacts Input / Output • 2 external contacts ❏ 2 connectors on rear panel ❏ 1 contact without supply (only contact closure) max. 30 V/250 mA ❏ 1 contact with internal 24 V supply (max. 250 mA output with fuse) • via motherboard ❏ stepper motor lines to optical unit ❏ lamp control to power supply ❏ connection to ASC board ❏ backplane bus Service Handbook for 1050 Series of HPLC Modules - 11/2001 461 DAD/MWD: Electronic Information Data Acquisition Board (AQB) Figure 163 Layout of AQB Board 462 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Firmware Board (FIM) Firmware Board (FIM) Repair Level: Board Table 109 Part Numbers for FIM Board Item Part Number also used for Firmware Board DAD/CE G1306-66524/-69524 G1600A CE Firmware Board MWD 01048-66504 The FIM board is a piggy back board, placed on AQB board (’personality module’). • The programmed FIM contains the firmware of the 1050 DAD module. • The board is designed for on board programming. • The FIM contains up to four 128K x 8bit EPROM (U4 to U7). • All inputs/outputs are pulled down for electrostatic discharge protection. Figure 164 Layout of FIM Board Service Handbook for 1050 Series of HPLC Modules - 11/2001 463 DAD/MWD: Electronic Information Common Main Processor Board (CMP) Common Main Processor Board (CMP) Repair Level: Board Table 110 Part Numbers for CMP Board Item Part Number also used for CMP Board 5061-3380/01050-69580 G1600A CE Common 1050 functions for the main processor are: • display handling • keyboard polling • remote control input and output • leak sensing • option interfacing • time programming • method storage • module configuration • memory switching • 32 kilobyte RAM with battery back-up for parameter storage. Firmware is not part of this board, because parts of the main processor’s software are module specific. The main processor firmware will be located on the ’personality module’ (AQB Board) or on an optional board. 464 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Common Main Processor Board (CMP) Figure 165 Block diagram CMP Service Handbook for 1050 Series of HPLC Modules - 11/2001 465 DAD/MWD: Electronic Information Common Main Processor Board (CMP) Remote Control The CMP board provides two remote connectors. Remote Signals Table 111 Pin Signal Active Color 1 Digital ground 2 Prepare run LOW brown 3 Start LOW gray 4 Shut down LOW blue 5 Reserved 6 Power ON HIGH yellow 7 Ready HIGH red 8 Stop LOW green 9 Start request LOW black white pink Remote Configuration The 1050 Series provides three remote configurations: HPsystem Start of automatic operation from any modules’ start key. Start request is outputted. GLOBAL Synchronized start of several modules for a single run. Start / Stop is outputted. LOCAL Single modules’ start. No pulses outputted. The signal level are defined as standard TTL levels (0 V is logic true, + 5 V is logic false). The remote lines can be input or output (wired or technique). • Fan-out is 10 • Input Load 2 kOhm against + 5 V • Outputs are open collector type 466 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Communication Interface (CRB) Communication Interface (CRB) Repair Level: Board Table 112 Part Numbers for CRB Board Item Part Number also used for CRB Board 5062-2482 G1600A CE The communication interface board is necessary for the control by a Personal Computer and to connect printer or plotter devices. The communication interface board provides one GPIB and one RS232 interface. The CRB for the 1050 DAD has a 96 kilobyte run buffer for the data/spectrum operation with the Multiple Wavelength Detector. The interface is located in Slot #2 of the module. The board contains a baud rate generator. The baud rate is selectable up to 19200 baud from the keyboard. The transmitter and receiver baud rate are independent adjustable. The implemented serial interface is a subset of the RS232 standard only. It contains at PIN 2 RxD receive data (data input) PIN 3 TxD transmit data (data output) PIN 4 GND (Ground) The 1050 modules are designed as DCE (data communication equipment) without hardware handshake. Service Handbook for 1050 Series of HPLC Modules - 11/2001 467 DAD/MWD: Electronic Information Digital to Analog Conversion Board (DAC) Digital to Analog Conversion Board (DAC) Repair Level: Board Table 113 Part Numbers for DAC Board Item Part Number also used for DAC Board 01048-66502 G1600A CE The main functions of the DAC board are: • conversion of digital data into analog signals compatible with external integrators; • provide two independent analog outputs. The DAC board comprises two independent pulse-width modulated 16 bit D/A converters with noise <1/4 LSB (peak to peak). The repetition rate for the data per channel is 90 Hz. The two analog outputs can be used for integrators and recorders. The rise time and the offset voltage is selectable per software. Output voltage: -4 ... 996 mV (1 V) or -0.4 mV ... 99.6 mV (100 mV) Scale factor: 0.5 V/AU or 0.05 V/AU (for multiplication factor =1) Rise Time (10/90%): 0.1/0.3/1/3 s Noise (0.1 s rise time): < 4 µV (< 0.008 mAU) 468 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Digital to Analog Conversion Board (DAC) Figure 166 Block diagram of DAC Board Service Handbook for 1050 Series of HPLC Modules - 11/2001 469 DAD/MWD: Electronic Information Digital to Analog Conversion Board (DAC) Address Decoder and Data Storage The digital signal prepared for conversion is sent from AQB through LUM data bus in 8 bit portions. The appropriate address is available on LUM address bus. This address is decoded by the address decoder and the data storage circuit is activated and the digital word is stored. The two channels are separated only through the appropriate address recognized by the address decoder. Timers Three 16 bit timers are available on the DAC. One is fixed as a divider (6.555 MHz/90 Hz) and provides the 90 Hz clock for the control logic. The other two timers work as Pulse width Modulator for channel 1 and 2. They are loaded with the digital word stored in the data storage and activated with a 90 Hz clock. Starting with the loaded word each counter will count downwards with the 6.555 MHz cycle. Pulse Width Modulator The pulses generated in the counter section are fed to diode switches that are responsible to switch the constant current source on or off to the low pass filter section. Low Pass Filter All low pass filters should suppress the 90 Hz cycle. The cutoff frequency is <4 Hz and suppresses the 90 Hz with >100 dB. The second low pass filter is a variable low pass filter dependent on the rise time (0.1/0.3/1/3 s). The third low pass filter has a variable gain which allows a scale factor for the analog output voltage at 50 mV/AU or 0.5 V/AU. Rise time The rise time is software selectable to 0.1 s, 0.3 s, 1 s, or 3 s. This rise time is varied in combination with the peak width setting. The default setting is 1 s. Refer to Operating Manual for more details. Power Supply The ±19 V from the Power Supply is used to generate ±15 V and + 10 V as a reference voltage for the constant current source. 470 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Digital to Analog Conversion Board (DAC) Board Diagnostics There are two possibilities to troubleshoot the DAC board: • output voltage check, see User Manual • D/A converter test, see “D/A Converter Test” on page 500 Both of these tests can be done on both output channels. Figure 167 Layout of DAC Board Service Handbook for 1050 Series of HPLC Modules - 11/2001 471 DAD/MWD: Electronic Information Fluorescent Indicator Module (FIP) Fluorescent Indicator Module (FIP) Repair Level: Board or Fuse ICP1 Table 114 Part Numbers for FIP Board Item Part Number FIP Board 5061-3376 Fuse 1 A 2110-0099 The FIP module is located behind the keyboard module of pump, autos ampler and multiple wavelength detector. The function of the FIP module is to provide an interface between a host system and the user. Messages can be displayed with up to 32 characters (2 lines x 16 characters/line). A matrix keyboard is scanned for numeric or special function input and status information is displayed through 4 LEDs. The characters are displayed in a 5 x 7 dot matrix. In case of a dark display, check the on board fuse ICP1 which is soldered in close to the connector P1/P2. Figure 168 Board Layout FIP 472 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Motherboard (LUM) Motherboard (LUM) Repair Level: Board Table 115 Part Numbers for LUM Board Item Part Number LUM Board 01048-66510 The Motherboard contains all connectors for the boards and the assemblies in the front part, like fans, optical unit and keyboard. Figure 169 shows the location of all connectors. Figure 169 Layout of Motherboard J1 - DPS J6 - Not used J10 - Shutter/Leak J2 - ASC J7 - CMP J11 - Lamp J3 - AQB J8 - FIP J12 - not used J4 - DAC J9 - PDA J13 - Fan (left) J5 - not used J14 - Fan (right) Service Handbook for 1050 Series of HPLC Modules - 11/2001 473 DAD/MWD: Electronic Information Motherboard (LUM) Figure 170 Connection Table LUM (I) 474 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Motherboard (LUM) Figure 171 Connection Table LUM (II) Service Handbook for 1050 Series of HPLC Modules - 11/2001 475 DAD/MWD: Electronic Information Motherboard (LUM) Figure 172 Connection Table LUM (III) 476 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information LPC Board LPC Board Repair Level: Board Table 116 Part Numbers for LUC/LPC Board Item Part Number also used for LPC Board 79883-66509 G1600A CE The board routes the signals from the leak sensor and signals to the shutter assembly. Via J3 it is connected to J10 of the LUM board (Motherboard). Figure 173 LPC Board Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 477 DAD/MWD: Electronic Information Power Supply (DPS-A) Power Supply (DPS-A) Repair Level: Fuses and DPS-A Table 117 Part Numbers for LUC/LPC Board Item Part Number also used for DPS-A 5061-3375/01050-69375 G1600A CE Fuse for 110 V operation 3 A 2110-0003 Fuse for 220 V operation 2 A 2110-0002 For detailed information refer to the 1050 Service Handbook, Chapter Common Information. General Description The power supply is a primary switching regulated type. It consists of two parts. the Base Supply and the Lamp Supply. The Base Supply provides outputs of +5 V, ±19 V, +24 V and +36 V. In addition the Lamp Supply provides all circuits necessary for the operation of a deuterium lamp. Lamp Ignition The heater output made by a series regulator is in the pre-heating status 2.5 V always. After ignition the heater voltage is switched off (DAD/MWD). Figure 174 Deuterium Lamp Ignition 478 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Power Supply (DPS-A) Figure 175 Block Diagram DPS-A (Base Supply) Service Handbook for 1050 Series of HPLC Modules - 11/2001 479 DAD/MWD: Electronic Information Power Supply (DPS-A) Figure 176 Block Diagram DPS-A (Lamp Supply I) 480 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Electronic Information Power Supply (DPS-A) Figure 177 Block Diagram DPS-A (Lamp Supply II) Service Handbook for 1050 Series of HPLC Modules - 11/2001 481 DAD/MWD: Electronic Information Power Supply (DPS-A) 482 Service Handbook for 1050 Series of HPLC Modules - 11/2001 21 21 DAD/MWD: Diagnostic & Troubleshooting Information This chapter provides information on error messages and diagnostic features of the 1050 Diode Array and Multiple Wavelength Detectors DAD/MWD: Diagnostic & Troubleshooting Information The 1050 DAD/MWD provides • STATUS information during the normal operation (e.g. conditions errors); • ERROR MESSAGES that identify the problem; • DIAGNOSTIC features on special request to allow troubleshooting of the module. 484 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information STATUS Information STATUS Information Status Modes • Status Modes • Status LEDs • Warnings SYSTEM INIT initializing ..... After turning on the module runs through an initialization. STANDBY 1050 STANDBY 01:A 0.00mAU All LEDs and the deuterium lamp are off. Edit of all parameters is possible (if PARAMETER LOCK is off). LAMP IGNITION LAMP ON <lamp is off> ENTER LAMP IGNITION 01:A 0.00mAU During the ignition process the NOT READY LED is on. PRERUN PRERUN 01:A 0.00mAU The same as in STANDBY mode except that the deuterium lamp is on now. Transition to RUN only possibly by pressing START (LOCAL) or via REMOTE. RUN timeprogram starting is displayed for 2 seconds. Then actual display shows RUN 01:A 0.00mAU. The RUN LED is on and the timetable commands are executed. The deuterium lamp cannot be switched to off. timeprogram stopped POSTRUN POSTRUN 01:A 0.00mAU The RUN LED is blinking. If post time has elapsed or STOP occurs the instrument switches to BALANCE mode (calibration) if auto calibration parameter is ON else to PRERUN mode. Service Handbook for 1050 Series of HPLC Modules - 11/2001 485 DAD/MWD: Diagnostic & Troubleshooting Information STATUS Information BALANCE balancing A calibration in performed and the NOT READY LED is on. SYSTEM TEST This mode is normally skipped and has to be called up through the TEST functions or during power on by pressing STATUS and LINE~ switch. Then ROM- RAM- and DISPLAY Test is performed. For details see “ROM/RAM/DISPLAY Tests” on page 507. Status LEDs ERROR LED ON This state indicates an error condition and requires an interaction of the user. A message will be written into the system logbook. The display will be overwritten with a messages: NOT READY LED ON This state indicates a NOT READY condition (action not yet finished see also mode description). A logbook entry is made. The following reasons may be reported on display for 2 seconds: • lamp ignition in progress • amp test in progress • balancing LAMP LED ON Deuterium lamp on. RUN LED ON Instrument in RUN mode. If instrument is in POSTRUN mode the RUN LED is blinking. Warnings A warning is written into the logbook if a problem occurs which doesn’t cause the user to stop analysis. A message is written to the display for 2 seconds. Possible warnings can be: • lamp below intensity test limit; • excessive leakage current of one of the photo diodes (non-linear); • intensity too high (wrong calibration at gradient run); • temporary memory overflow. 486 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information Error Messages Error Messages This section describes the troubleshooting of the 1050 DAD/MWD according to the error messages. The error messages will help to locate and repair a failure. In case an error message appears the Error LED will be turned on and the message will be written into the system logbook. Selftest ROM RAM and display can be tested via the build in selftest. The selftest will be performed when STATUS will be pressed while the module is turned on at the LINE~ switch. In case of a failure one of the following messages appears. The complete test requires approximately two minutes. ROM test failed ( ROM test failed ) The ROMs on the FIM board are tested. In case of a checksum error the ROM test fails. Replacement of the FIM board will probably fix the problem. RAM test failed ( RAM test failed ) The RAM’s on the CMP board will be tested. In case of a failure the error message appears and the CMP has to be replaced. Service Handbook for 1050 Series of HPLC Modules - 11/2001 487 DAD/MWD: Diagnostic & Troubleshooting Information Common 1050 Error Messages Common 1050 Error Messages The common messages are either event or error messages which may appear in all the 1050 series modules. The messages are identical or very similar in the various modules. E00: Power Fail E00 HH:MM DDMMM power fail > clock stopped set time&date This message indicates that the instrument has either been disconnected from line source or a line power voltage drop occurred. E01: Leak Detected In E01 HH:MM DDMMM leak detected > Detector leak detected > in detector The leak detection circuit is located on the CMP board and checks continuously for presence and leak conditions. If the sensor is missing (defect) or in leak condition the PTC is cooled down the error message appears. When the module is turned on the leak message is disabled for some time to allow the sensor to reach its working range. The deuterium lamp is switched OFF. Working condition of the PTC Normal: about 75°C 400...500 Ohm Error: below 55°C about 150 Ohm Actions: ❏ Check connector of the sensor. ❏ Check resistance of leak sensor. ❏ Change leak sensor. ❏ Change CMP board. ❏ Change FIM board. 488 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information Common 1050 Error Messages E02: Error In Other Module E02 HH:MM DDMMM shut down > serious error in other module An external device pulled the shut down line down (pins 1 and 4 of REMOTE connector), for example when a leak is detected. E03: Error Method loaded E03 HH:MM DDMMM error method > error method has been loaded An error has come up in the DAD and this caused to load an error method (if specified) and turned off the lamp. E04: Time Out E04 HH:MM DDMMM time out > lamp turned off automatically If the time after finishing the last run or a not ready condition exceed the value of set time-out time the deuterium lamp is turned off automatically. A time out occurs (pin 1 and 7 of REMOTE connector). E05: Turn On Lamp Automatically E05 HH:MM DDMMM lamp has been > turned on automatically If the lamp was programmed to be turned on automatically this message is displayed. Service Handbook for 1050 Series of HPLC Modules - 11/2001 489 DAD/MWD: Diagnostic & Troubleshooting Information 1050 DAD/WMD Error Messages 1050 DAD/WMD Error Messages The following error messages are 1050 DAD/MWD specific. E11/12: WL Calibration out of range E11 HH:MM DDMMM WLcalibration > WLcal factor more than +12 E12 HH:MM DDMMM WLcalibration > WLcal factor more than -12 This message occurs when the wavelength calibration test failed. Actions: ❏ Check whether the cell is inserted properly. ❏ Check for air bubbles in cell. ❏ Perform WL-Calibration Test. E13: Spectra buffer full E13 HH:MM DDMMM spectramem.full> not all ttbl spectra stored Too many spectra were taken during time program. Actions: ❏ Reduce number of spectra or time programmed spectra. E14: No lamp current E14 HH:MM DDMMM lamp failed > no lamp current lamp is off Actions: ❏ Check lamp. ❏ Change lamp current. ❏ Check connections. ❏ Replace power supply. ❏ Replace AQB board. 490 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information 1050 DAD/WMD Error Messages E15: Lamp ignition failed E15 HH:MM DDMMM ignition failed> lamp failed during ignition Actions: ❏ Turn lamp on. ❏ Check lamp connector. ❏ Perform lamp test. ❏ Change lamp. ❏ Replace AQB. ❏ Replace power supply. E16: Low intensity E16 HH:MM DDMMM intensity test> low intensity make lamptest Actions: ❏ Perform lamp test. ❏ Change lamp. ❏ Change flow cell. E17: Data overflow E17 HH:MM DDMMM data overflow > intensity too high Actions: ❏ Check whether cell is inserted correctly. ❏ Reduce lamp current. ❏ Change lamp. E18: Data underflow E18 HH:MM DDMMM data underflow> ASC data too low Actions: ❏ Check whether cell is inserted correctly. ❏ Increase lamp current. ❏ Change lamp. ❏ Change ASC, cable, AFE. Service Handbook for 1050 Series of HPLC Modules - 11/2001 491 DAD/MWD: Diagnostic & Troubleshooting Information 1050 DAD/WMD Error Messages E19: Lamp turned on automatically E19 HH:MM DDMMM lamp turned on> lamp turned on automatically The lamp has been switched on per time program. 492 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information Diagnostic Features Diagnostic Features The instrument offers several built-in test features. Some are limited to ChemStation operation (for details see descriptions of tests): • intensity test • holmium oxide test • lamp intensity test • ASC test • D/A-Converter test • electronic noise test • close/open shutter • check wavelength calibration • RAM test • ROM test • Display test N OT E When using these test functions the 1050 DAD/MWD must not be in RUN MODE. Press BALANCE prior to perform the test. When test cell is mentioned, remove cell and insert 4 nm slit for Series II optical Entering the Test Functions You are entering the TEST FUNCTIONS by pressing STATUS followed by PREV (4x). TEST FUNCTIONS <enter> ENTER. Service Handbook for 1050 Series of HPLC Modules - 11/2001 493 DAD/MWD: Diagnostic & Troubleshooting Information Measure Intensity Profile Measure Intensity Profile N OT E This function is available from local keyboard only! An intensity profile of the optical unit is measured. No calibration is made before the measurement and the actual gain values are used. Perform this test after the flow cell is flushed or removed with 4 nm slit installed. MEASURE INTENSITYPROFILE Taking the Profile After pressing ENTER the message scanning ... is displayed for a second and an intensity measurement between 190...600 nm is taken and stored like a spectrum. The wavelength and the count number at maximum are displayed max at max 17805cts at 234nm ; 0.00min. Plotting the Profile (MWD only) ❏ Press SPECTR and RIGHT to display PLOT 01 REF -- ;ints 0.00min. ❏ You can change now the wavelength range (190...600 nm) and the output channel (out 1) if necessary. ❏ Press ENTER. START INTEGR. AT SPEED=30 (enter) ❏ Start the integrator with the PLOT key and the spectrum of the intensity profile is plotted after pressing ENTER. ❏ When the plot has finished max 17805cts at 234nm ; 0.00min is displayed. ❏ Press ESC to return to beginning of line. 494 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information Measure Intensity Profile Find Maximum of Spectrum (MWD only) ❏ Press SPECTR, DOWN and RIGHT. MAX. 01 REF -- ;ints 0.00min ❏ You can change now the wavelength range (190...600 nm) and the output channel if necessary. ❏ The maximum is shown after pressing ENTER. max 17805cts at 234nm ; 0.00min Figure 178 Intensity Profile with Test Cell Service Handbook for 1050 Series of HPLC Modules - 11/2001 495 DAD/MWD: Diagnostic & Troubleshooting Information Lamp Intensity Test Lamp Intensity Test N OT E This function is available from local keyboard and from ChemStation! An integral measurement of the lamp intensity is made in the range of 210 to 350 nm and the average counts are displayed (test is performed with minimum gain = 0). Now you can retrieve the plots or the maximum information. The plotted curve should be within ±3% deviation from the intensity profile. Otherwise the gain switching on the ASC board may not work properly. N OT E The characteristics vary from instrument to instrument depending on optics lamp and array characteristics. Figure 179 DAD/MWD Test: Lamp Intensity 496 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information Lamp Intensity Test On local keyboard If performed locally the display shows: LAMP INTENSITY TEST ; 0 ENTER LAMP INTENSITY TEST ; 14296 On ChemStation If performed on the ChemStation this test is part of the DAD Test, see Figure 179 on page 496. The profile (190 to 600 nm) is stored on the ChemStation. ❏ Select Instrument, More DAD, DAD Tests... ❏ Press Measure and the instrument will perform the Lamp Intensity Test and the Holmium Test automatically. ❏ Press Save to store both profiles. ❏ To print the profile refer to How to print the DAD Profiles, page 5-29. Service Handbook for 1050 Series of HPLC Modules - 11/2001 497 DAD/MWD: Diagnostic & Troubleshooting Information Measure Holmium Spectrum Measure Holmium Spectrum N OT E This function is available from ChemStation only! The shutter is moved to holmium filter position and a spectrum is measured and plotted (full scale set to 4 AU). Perform a BALANCE before entering this function. The scan (190 to 600 nm) is stored. N OT E The characteristics vary from instrument to instrument depending on optics lamp and array characteristics. Figure 180 DAD/MWD Test: Holmium Spectrum N OT E At least one point should be >3000 mAU in the range of 190...300 nm. 498 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information Measure Holmium Spectrum On ChemStation On the ChemStation this test is part of the DAD Test, see Figure 180. The profile (190 to 600 nm) is stored on the ChemStation. ❏ Select Instrument, More DAD, DAD Tests... ❏ Press Measure and the instrument will perform the Lamp Intensity Test and the Holmium Test automatically. ❏ Press Save to store both profiles. ❏ To print the profile refer to How to print the DAD Profiles, page 5-29. On local keyboard MAX. 01 REF -- ;holm 0.00min ENTER max 3912mAU at 228nm ; 0.00min Service Handbook for 1050 Series of HPLC Modules - 11/2001 499 DAD/MWD: Diagnostic & Troubleshooting Information D/A Converter Test D/A Converter Test N OT E This function is available from local keyboard only and is used to test the DAC board (DAD optional)! D/A CONVERTER TEST OFF D/A CONVERTER TEST ON The DAC board is tested by generation of a test pattern as DAC input. The output voltages (out 1 and out 2) should show a constant value corresponding to the ZERO OFFSET value. On top of this constant voltage is a switched voltage with a duration of 12 seconds and a height of 15 µV, see Figure 181. Figure 181 D/A Converter Test If the D/A converter and the plotting device are in specification then the noise is depending on the peak width (5 µV are equal to 1 x 10-5 AU). 500 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information D/A Converter Test When the function is switched on start the plotter (ATTN -5, ZERO=50) and zero it. Table 118 Limits of D/A Converter Test Peak widths Noise (pp) / Step height < 0.01 / > 0.01 / > 0.02 1.3 > 0.05 / > 0.1 / > 0.2 0.5 > 0.4 / > 0.8 0.3 Service Handbook for 1050 Series of HPLC Modules - 11/2001 501 DAD/MWD: Diagnostic & Troubleshooting Information Electronic Noise Test Electronic Noise Test N OT E This function is available from local keyboard only! ELECTRONIC NOISE TEST OFF ELECTRONIC NOISE TEST ON The optical unit and its electronic is tested with the possibility of changing the parameters wavelength bandwidth peak width (before entering this function). The shutter is closed and the gain is fixed to minimum=0. You can leave this function ONLY by switching to OFF. Figure 182 Electronic Noise Test With this test non-logarithmic intensity is measured. Result of test must not exceed a given limit. If test fails the ASC DAC or optical unit may be defective. If DAC test is OK then ASC or optical unit may be the problem. 502 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information Electronic Noise Test Table 119 Limits of Electronic Noise Test Peak width Rise time µVpp Limit 3390/2/3 Limit 3394/96 ATTN < 0.01 0.1 s 90 13.5 mm 27 mm -1 > 0.01 0.2 s 90 13.5 mm 27 mm -1 > 0.03 0.3 s 50 15.0 mm 30 mm -2 > 0.05 1.0 s 30 18.0 mm 36 mm -3 > 0.10 1.3 s 30 18.0 mm 36 mm -3 > 0.20 2.6 s 20 12.0 mm 24 mm -3 > 0.40 5.2 s 20 12.0 mm 24 mm -3 > 0.85 10.0 s 20 12.0 mm 24 mm -3 Measurement conditions Any sample wavelength, bandwidth 4 nm, reference is switched off automatically, 1 V full scale. Table 120 NOISE 1: Test as described. NOISE 2: Test as described under NOISE 1 but with PDA/LUM cable disconnected Noise Test Results Result Explanation System OK If NOISE 1 > NOISE 2 and in specification. Electrical Problem If NOISE 1 > limit and NOISE 2 >= limit. Optical Problem If NOISE 1 > limit and NOISE 2 < NOISE 1 Service Handbook for 1050 Series of HPLC Modules - 11/2001 503 DAD/MWD: Diagnostic & Troubleshooting Information Check of Wavelength Calibration Check of Wavelength Calibration N OT E This function is available from local keyboard and from ChemStation. The maximum absorbance of the Holmium filter is measured at 361 nm and compared with a stored value. The difference in wavelength is displayed. On local keyboard CHECK WL CALIBRATION IT SHOULD BE 2 AND IT IS 0 The value of 2 corresponds to 1 nm. To change/correct the setting use function SET WL CALIB. On ChemStation ❏ Select Instrument, More DAD, Wavelength Calibration. ❏ The wavelength calibration is started automatically (if lamp is on) see Figure 183. ❏ If the value of Current and Should be is not equal then use Adjust to correct. ❏ Press OK to store the new values and to add them to the Calibration history. ❏ To print the profiles refer to How to print the DAD Profiles page 5-29. Figure 183 Wavelength Calibration 504 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information ASC Test ASC Test N OT E This function is available from local keyboard only! ASC TEST WITH GAIN 0 ; 0 ASC TEST WITH GAIN 0 ; 3871 ASC TEST WITH GAIN 1 ; 4462 ASC TEST WITH GAIN 2 ; 4654 The ASC board is tested by closing the shutter and measuring the dark current of the photo diodes with three possible gains (0, 1, 2). Start test with minimum gain first. High values may reflect in a non-linearity. (Default is minimum gain = 0). The value that is shown is the average dark current counts of a all photo diodes. A value between 2500...5500 is the limit measured with gain 0. The value in gain 1 and 2 may have a difference of ±1500 compared to the value from gain 0. N OT E High values may reflect in a non-linearity. The scan (190 to 600 nm) is stored. You can change now the wavelength range (190...600 nm) and the output channel if necessary. Now you can retrieve the plots or the maximum information. MAX. 01 REF -- ;tasc 0.00min ENTER max 3885cts at 475nm ; 0.00min N OT E If the difference between average and maximum is >100 then the array has a problem at this particular wavelength. This might be no problem if the customer is using a different wavelength. Service Handbook for 1050 Series of HPLC Modules - 11/2001 505 DAD/MWD: Diagnostic & Troubleshooting Information Shutter Position Shutter Position N OT E This function is available from local keyboard only! SHUTTERPOSITION OPEN SHUTTERPOSITION HOLMIUM/CLOSED The shutter can be positioned manually to OPEN, HOLMIUM and CLOSED (dark current). Leave this function by switching to OPEN. 506 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information ROM/RAM/DISPLAY Tests ROM/RAM/DISPLAY Tests The following functions are also performed during power on when both STATUS and the LINE~ switch are pressed. ROM TEST (enter) The ROM checksum is compared with a stored value and the firmware revision is displayed. ROM TEST <executing> ( ROM test failed ) Action: Replace the FIM board. RAM TEST (enter) The RAM is tested. RAM TEST <executing> ( RAM test failed ) Action: Replace CMP board. DISPLAY TEST (enter) The 32 characters of the display and the LEDs are tested. This test is the same as performed during power on. DISPLAY TEST <executing> Action: If the display shows nothing, check first the soldered in on-board fuse, see “Fluorescent Indicator Module (FIP)” on page 472. Service Handbook for 1050 Series of HPLC Modules - 11/2001 507 DAD/MWD: Diagnostic & Troubleshooting Information Using the Built-in Test Chromatogram Using the Built-in Test Chromatogram N OT E This function is available from ChemStation only! The 1050 DAD has a built-in Test Chromatogram that can be used to check the signal path from the detector to the ChemStation and the data analysis. See Figure 184 and Figure 185 on page 509. The chromatogram is repeated continuously until a stop is performed per stop time or manually. To use the function proceed as follows: ❏ Set peak width to >0.05 minutes and run time to 4.5 minutes. For a peak width of <0.01 the stop time can be set to 0.6 minutes. ❏ Type into the command line LoadSignal1050DAD INTERNAL. The detector status goes to Prerun (Test) / Ready. ❏ Start a run. The results are calculated like a normal chromatogram and the results can be printed. ❏ The peak height is always the same but the area and the retention time is depending on the set peak width. 508 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information Using the Built-in Test Chromatogram Figure 184 Test Chromatogram: Peak width <0.05 Figure 185 Test Chromatogram: Peak width <0.01 Service Handbook for 1050 Series of HPLC Modules - 11/2001 509 DAD/MWD: Diagnostic & Troubleshooting Information Using the Built-in Test Chromatogram How to print the DAD Profiles Figure 186 shows the ChemStation screen when having performed the DAD Test. Figure 186 DAD Test Using Paintbrush ❏ Press ALT and Print Screen keys to make screen capture. ❏ Leave the DAD Test and enter Paintbrush from the Program Manager. ❏ Select View and click Zoom Out. ❏ Select Edit and Paste (2x). ❏ Select View and click Zoom In. ❏ Select File, Print and [[OK]]. 510 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Diagnostic & Troubleshooting Information Using the Built-in Test Chromatogram Using the Data Editor ❏ Select View, Data Analyses. ❏ Select View, Review DAD Test... ❏ Select from the table the spectrum of interest see Figure 187 or Figure 188. ❏ Press [[Show Selected Spectrum]] and select the window. At this point you may zoom a certain part of the profile. ❏ Select File, Print, Selected Window for print. Figure 187 DAD Test: Lamp Intensity Service Handbook for 1050 Series of HPLC Modules - 11/2001 511 DAD/MWD: Diagnostic & Troubleshooting Information Using the Built-in Test Chromatogram Figure 188 DAD Test: Holmium 512 Service Handbook for 1050 Series of HPLC Modules - 11/2001 22 22 DAD/MWD: Maintenance Information This chapter provides provide procedures for service and maintenance of the 1050 Diode Array and Multiple Wavelength Detectors DAD/MWD: Maintenance Information This chapter describes the following procedures that have to be performed during servicing and maintenance of the 1050 DAD. • removing the optical unit; • flow cell maintenance; • cleaning the quartz window; • replacing fans; • replacing shutter assembly or LUC/LPC board; • replacing the leak sensor; • upgrade to new optical unit; • performance verification. Tools Needed ❏ Screw driver flat 6 mm ❏ Hex wrench 6 mm ❏ Hex wrench 4 mm and length of 200 mm ❏ Pozidriv small ❏ cleaning tissue 514 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Maintenance Information Warnings and Notes WA R N I N G Dangerous voltages capable of causing serious personal injury are present in this instrument. Use extreme caution when handling testing and adjusting. N OT E DO NOT open the screws of the large cover of the optical unit. This may result in misalignments of the optical path. exchange lamp housing. They are matched to the optical and replacement may result in a misalignment of the optical path. return defective exchange optical without information about the problem (use attached info-note). return flooded optical without information about the last used solvents (this is needed for recycling). N OT E The lamp housing may be hot when you have to work at the optical unit. Service Handbook for 1050 Series of HPLC Modules - 11/2001 515 DAD/MWD: Maintenance Information Removing the Optical Unit Removing the Optical Unit ❏ Turn OFF the instrument and unplug the power. ❏ Remove top cover. ❏ Disconnect flow cell at union holder [2], remove cell from optical unit and place it in front of the heat exchanger. ❏ Disconnect PDA [6] and Shutter [5] cable at optical unit and the Display cable at the motherboard (LUM). ❏ Disconnect lamp connector [1]. ❏ Disconnect the waste tube [3]. ❏ Loosen the three bolts [4] that hold the optical unit (4 mm hex key > 100 mm long) and take out the optical unit. Figure 189 Optical Unit 1 - deuterium lamp 2 - union holder 3 - waste tube 4 - bolts 5 - connector shutter 6 - connector PDA 516 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Maintenance Information Flow Cell Maintenance Flow Cell Maintenance Flushing Procedure To cleaning the flow cell (by using a glass syringe!) perform as described below: 6 Flush with iso-Propanol. 7 Flush with bi-distilled water. 8 Flush with nitric acid : water (5 : 95). 9 Flush with bi-distilled water. 10 Flush with iso-Propanol C A UT I O N This concentration of nitric acid is dangerous and proper attention to safety should be given. Also the nitric acid flushing procedure is not a certain cure for a dirty cell. It is to be used as a last attempt to salvage the cell before cell replacement. Note that the cell is essentially a consumable item. Service Handbook for 1050 Series of HPLC Modules - 11/2001 517 DAD/MWD: Maintenance Information Flow Cell Maintenance Replacements on Standard Flow Cells Replacing the Gaskets ❏ Take out the flow cell. ❏ Take a flat screwdriver (6 mm width) or a 6 mm hex wrench and turn out the flow cell window assembly [1]. ❏ In case of an leakage replace the gasket [2]. ❏ Fix the flow cell window assembly. Figure 190 Disassembled Flow Cell Replacing Window Assembly Parts ❏ Take out the flow cell window assembly (Figure 190, item 1). ❏ Take out the quartz window carefully by pressing it out of the window holder. N OT E If the washers have fallen out of the assembly they have to be inserted in the correct order. Otherwise the window may break or will be leaky see. ❏ Clean or replace the window. ❏ Fix the window assembly. 518 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Maintenance Information Flow Cell Maintenance 1 Flow cell window assembly. 2 Window assembly schematic. 1 - window screw 2 - spring washers 3 - compression washers 4 - window holder 5 - quartz window 6 - gasket 3 Assembling of the washers. 4 Assembling of Teflon ring and window assembly. Service Handbook for 1050 Series of HPLC Modules - 11/2001 519 DAD/MWD: Maintenance Information Flow Cell Maintenance 5 Replacing flow cell window in window assembly. Replacements on High Pressure Flow Cells For cleaning the flow cell windows you will need ❏ a 4 mm hexagonal key (supplied with flow cell) ❏ a 20 mm open-ended wrench ❏ tweezers and ❏ a toothpick. Figure 191 Cross-section of Window Assembly Washer Windows Washer Conical Disk Springs (see below) Window Screw Detail of Conical Disk Springs Showing Orientation 520 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Maintenance Information Flow Cell Maintenance Stage 1: Disassembling the Window Assembly ❏ Take flow cell out of optical unit. ❏ Unscrew window assembly (see Figure 191) using a 4 mm hexagonal key--use a 20 mm open-ended wrench to hold the flow cell. ❏ Carefully take out window using a toothpick or a 4 mm hexagonal key. ❏ Take out the conical disk springs and discard them. ❏ Clean window in ultrasonic bath filled with methanol or ethanol. Stage 2: Assembling the Window Assembly ❏ Put conical disk springs in window screw see Figure 191. Always use new conical disk springs. ❏ Press window and seal rings together using tweezers. ❏ Put window and seal rings in window screw. Keep window facing upwards to prevent it falling out. ❏ Screw window assembly into flow cell until finger tight. ❏ Tighten window assembly using a 4 mm hexagonal key, use a 20 mm open-ended wrench to hold flow cell. ❏ Check flow cell for leaks. If you have an 1050 Series pumping system use flow test method described in Installing and Maintaining Your Pumping System. Connect inlet capillary of flow cell to pump outlet. Connect blank nut to outlet capillary of flow cell. If flow cell leaks tighten window screw and check again for leaks. ❏ Put flow cell in optical unit. Service Handbook for 1050 Series of HPLC Modules - 11/2001 521 DAD/MWD: Maintenance Information Lamp House Window Maintenance Lamp House Window Maintenance This procedure can to be performed in case the intensity gets low and lamp exchange does not increase the light trough put. Between the lamp housing and the achromat lens system a quartz window is located to protect the achromat against contaminations. Removing the Quartz Window Refer to Figure 192 on page 523. ❏ Take optical unit out of the instrument. ❏ Remove the lamp housing (2 screws). ❏ Remove the securing ring (1) with a pliers. ❏ Take out the spring (2) the aperture (3) and the window (4). ❏ Clean or replace the window. N OT E Use ethanol or methanol and lens paper to clean the window. DO NOT touch or scratch the surface of the window. This will result in loss of intensity. ❏ Replace all parts in correct order. Watch for correct direction of the aperture! 522 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Maintenance Information Lamp House Window Maintenance Figure 192 Removing Lamp House Parts 1 Removing of lamp housing. 2 Removing the quartz window. 1 = Securing Ring, 2 = Spring, 3 = Aperture, 4 = Window Service Handbook for 1050 Series of HPLC Modules - 11/2001 523 DAD/MWD: Maintenance Information Replacing the Achromat Replacing the Achromat To replace the achromat assembly proceed as follows: ❏ Switch off the power from the instrument. ❏ Take the optical unit out of the instrument. ❏ Remove the cover plate above the flow cell/shutter compartment. C A UT I O N Do not touch the AFE connector board! ❏ Unscrew the achromat assembly (hex key) and remove it. ❏ Insert the new achromat assembly completely and fix it. ❏ Replace the optical cover and reconnect the cables. ❏ Reinstall the optical unit and turn on the power. ❏ Perform a WL CALIBRATION TEST and correct the ‘is’ and ‘should be’ values if required (should be within ±3 steps from the original value from step 1). If not within the range, rotate the achromat and repeat this step. Figure 193 Location of Achromat Assembly AFE Connector Setscrew Achromat Assembly 524 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Maintenance Information Replacing Fans Replacing Fans ❏ Remove top cover and disconnect ALL cables from Motherboard. Figure 194 Removing Fans Fan cover not shown ❏ Take out the foam part which contains the fans completely. N OT E Take care that no connector on the Motherboard breaks when removing or inserting the foam part. ❏ Note the position of the fan and replace it (arrow on the fan). ❏ Replace foam part carefully into the module. ❏ Connect ALL cables at the Motherboard and replace top cover. Service Handbook for 1050 Series of HPLC Modules - 11/2001 525 DAD/MWD: Maintenance Information Replacement of Shutter or LPC Board Replacement of Shutter or LPC Board In case the shutter assembly or the LPC board shows a malfunction it can be replaced. Figure 195 Shutter Assembly ❏ Remove the main cover to have access to optical unit. ❏ Disconnect flow cell and remove it. ❏ Remove slit assembly. ❏ Remove the cover of the optical compartment (5 screws). ❏ Disconnect LPC board from shutter assembly. ❏ Replace shutter assembly or LPC board. ❏ Replace all parts in correct order. 526 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Maintenance Information Replacement of Leak Sensor Replacement of Leak Sensor In case the leak sensor assembly shows a malfunction it can be replaced. Figure 196 Leak Sensor Assembly ❏ Remove the main cover to have access to optical unit. ❏ Disconnect flow cell and remove it. ❏ Remove slit assembly. ❏ Remove the cover of the optical compartment (5 screws). ❏ Disconnect leak sensor from LPC board using a pliers. ❏ Replace leak sensor. ❏ Replace all parts in correct order. Service Handbook for 1050 Series of HPLC Modules - 11/2001 527 DAD/MWD: Maintenance Information Upgrade to from 79854A MWD to G1306A DAD Upgrade to from 79854A MWD to G1306A DAD When upgrading 79854A MWD to DAD capabilities the keyboard and the firmware board has to be exchanged. For parts list refer to “Upgrade Parts MWD to DAD” on page 546. C A UT I O N Electronic boards are sensitive for electrostatic discharge. Use ESD protection when replacing electronic boards. ❏ Remove the AQB board. ❏ Update the firmware board (FIM) to DAD version. ❏ Install the AQB board. ❏ Disconnect cable from keyboard electronics (FIP) to LUM (motherboard). ❏ Remove keyboard module from instrument. ❏ Remove metal cover at the rear. ❏ Remove FIP from MWD keyboard module. ❏ Install FIP into DAD keyboard module. ❏ Install keyboard module in the instrument. ❏ Reconnect cables. 528 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Maintenance Information Upgrade MWD with Series II Optical Upgrade MWD with Series II Optical N OT E For required parts refer to “Upgrade Parts MWD to Series II Optical” on page 547. 1 If an AQB board 01048-66543 (latest version) is installed skip step 2 and 3. 2 Check the AQB board for presence of 220 Ohm resistor that is located between fuse F22 and the rear connector J1 (SN 01050-016). If not exist, replace. 3 Q1C should be cut out only if the resistor on the AQB, mentioned in SN 01050-016, has a value of 220 ohms and the firmware has revision 3. Otherwise the current will be too low to move the shutter correctly (SN 01050-021A). 4 Install new FIM board (3.10) if required. 5 Install series II optical unit. 6 Install series II flow cell. 7 Reconnect capillaries. 8 Check for leaks. Service Handbook for 1050 Series of HPLC Modules - 11/2001 529 DAD/MWD: Maintenance Information Verifying the Performance Verifying the Performance Specifications The noise and drift specifications of your detector are 4 x 10-5 AU and 2 x 10-3 AU/h respectively at 254 nm, 4 nm bandwidth, 1 second response time and 1 ml/min flow of water after warm-up. What You Need To check these specifications you need: • A pump that can deliver bi-distilled water at a rate of up to 1 ml/min against a back-pressure of about 200 bar; • A column: we recommend a 100 x 4.6 mm i.d. 5 µm Hypersil ODS column. • A recording device that can accept the output signal from your detector and that has attenuation set to about 35 cm/mV. Preparations ❏ Prime the pump and ensure there are no air bubbles in the system. ❏ Thoroughly degas about 300 ml of bi-distilled water. ❏ Set pump to deliver bi-distilled water at a flow rate of 1 ml/min. ❏ Set the attenuation of the recording device to about 35 cm/mV. ❏ Set run time to 6.0 minutes. ❏ Turn ON detector and allow intensity of emitted radiation from radiation source to stabilize. ❏ Set detection wavelength to 254 nm and bandwidth to 4 nm. Set reference wavelength to 450 nm and bandwidth to 100 nm. ❏ Set peak width to >0.05 minutes. ❏ Set output signal so that 1 AU is equivalent to 0.5V. ❏ Start a run, press [[START]] [[ENTER]]. 530 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Maintenance Information Verifying the Performance The baseline noise should not exceed 20 µV (4 x 10-5 AU) equivalent to 12 mm at attenuation - 3 on a3390/2/3 integrator and equivalent to 24 mm at attenuation - 3 on a 3394/6 integrator. Figure 197 Example of Noise Plot Service Handbook for 1050 Series of HPLC Modules - 11/2001 531 DAD/MWD: Maintenance Information Verifying the Performance Scaling Factors The table below shows the scaling factors for the 339XA family of integrators. The 3390A, 3392A and 3393A have a full scale deflection of 75 mm. The 3394A and the 3396A have a full scale deflection of 150 mm, they also have an attenuation range between -8 and 36. Table 121 Scaling Factors on 339X integrators ATTN mV full scale mAU full scale -3 0.125 0.25 -2 0.25 0.5 -1 0.5 1 0 1 2 1 2 4 2 4 8 3 8 16 4 16 32 5 32 64 6 64 128 7 128 256 8 256 512 9 512 1024 10 1024 2048 532 Service Handbook for 1050 Series of HPLC Modules - 11/2001 23 23 DAD/MWD: Parts Information This chapter provides information on parts of the 1050 Diode Array and Multiple Wavelength Detectors DAD/MWD: Parts Information This chapter gives diagrams for parts identification and the complete parts listings respectively. • Overall Diagram • Optical Unit • Heat Exchanger and Flow Cell • Flow Cell Kits • Upgrade Parts MWD to DAD • Accessory Kit 534 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Parts Information Overall Diagram Overall Diagram Table 122 Overall Diagram Item Description Part Number 1 Fan Base (set of two) 01048-47701 2 Fan DC Axial 01048-68500 Fan Cover 3160-0544 # 3 Mainframe Item Description 24 Keyboard Module (DAD) Keyboard Module (MWD) Part Number 01048-60202 01048-60201 25 FIP Board 5061-3376 26 Cable FIP/LUM 5061-3400 4 Screw M4 20 mm lg 0515-0175 27 Optical Unit see page 538 5 Screw M3.5 8 mm lg 0515-0889 28 Cable PDA/SHUTTER-LUM 5062-2410 6 Foot Rear 0403-0427 29 Heat Exchanger/Flow Cell see page 540 7 Foot Front 5041-2161 30 Cable Lamp/LUM 01048-61603 8 Cover Hinge 5041-2147 # 31 Cover Power Supply 01048-04104 9 PWR Switch Actuator 5041-2162 32 Power Supply Assembly 01050-69375 10 PWR Switch Spring 1460-1510 33 ASC Board Assembly 01048-66501 11 PWR Switch Push Button G1600-47400 34 AQB Board Assembly 01048-69543 35 FIM Board Assembly (DAD) G1306-66524 #12 Frame + Cover Keyboard (42) 13 Filter Part of 16 FIM Board Assembly (MWD) 01048-66504 14 Ring Filter Part of 16 Screw M3 6 mm lg 0515-0886 15 Logo Base/Name Plate 5041-2144/n.a. 36 DAC Board Assembly 01048-66502 16 Front Panel (incl. 13, 14) 01048-60301 37 Plate Cover (33 mm width) 5001-3721 17 Power Switch Base 5041-2145 38 CMP Board Assembly 01050-69580 18 Leak Interface TOP 5062-8551 39 Top Cover 5001-3724 19 Leak Interface BOTTOM Part of 18 20 Leak Interface Adapter Part of 18 41 LUM Mother Board Assembly 21 Tube Flexible 6.5 mm i.d. (5 m) 5062-2463 43 Communication Interface Board CRB 5062-2482 22 Tube Flexible 0.7 mm i.d. (5 m) 5062-2462 23 Bolt 5041-2164 # 40 Card Cage Assembly 01048-84501 01048-66510 # These items are part of Sheet Metal Kit 01048-68701 Service Handbook for 1050 Series of HPLC Modules - 11/2001 535 DAD/MWD: Parts Information Overall Diagram Figure 198 Overall Diagram Part 1 (Series II) 536 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Parts Information Overall Diagram Figure 199 Overall Diagram Part 2 (Series II) Service Handbook for 1050 Series of HPLC Modules - 11/2001 537 DAD/MWD: Parts Information Optical Unit Optical Unit Table 123 Optical Unit Item Description Part Number Item Description Part Number # Optical Unit - New 01048-60024 # 15 Flow Cell Assembly STD see page 541 # Optical Unit - Exchange 01048-69024 Flow Cell Assembly HP-STD see page 542 79883-61901 Flow Cell Assembly HP-Micro see page 543 0515-0886 Cell Clamp Assembly 79883-85001 79883-66509 Screw M2.5 6mm lg 0515-1056 # 1 Shutter Assembly 2 Screw M3 6mm lg # 3 LPC Board Assembly 4 Screw M2.5 6mm lg 0515-0894 # 16 Capillary IN 0.17 79883-87303 5 Bolt 5021-1853 # 17 Capillary OUT 0.17 79883-87304 6 RFI Strip 01048-09101 18 Union 0100-0900 7 Damper 5041-2165 19 Clamp Union 79883-00502 8 Deuterium Lamp Assembly 79883-60002 9 Screw M3 10mm lg 0515-0757 21 Heat Exchanger Assembly 01048-87305 10 Union Holder 01048-02321 22 Screw M3 8mm lg 0515-0897 11 Screw M3 8mm lg 0515-1430 23 Tubing Flexible 80mm lg 0890-0581 12 Set Screw M3 6mm lg 0515-0031 24 Elbow Fitting (Plastic) 0100-1428 13 Union 0100-0900 25 Leak Sensor Assembly 5061-3356 # 14 Slit Assembly 2 nm 79883-80002 26 Nut M3 0535-0004 Slit Assembly 4 nm 79883-80004 27 Screw M3 8mm lg 0515-1430 Slit Assembly 8 nm 79883-80008 # 20 Screw 0515-0922 # 28 Cover Illum Compartment 79883-04101 # 29 Achromat Assembly 79883-60000 # These parts are not interchangeable with the previous optical unit design (Series I). 538 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Parts Information Optical Unit Figure 200 Optical Unit 29 Service Handbook for 1050 Series of HPLC Modules - 11/2001 539 DAD/MWD: Parts Information Heat Exchanger and Flow Cell Heat Exchanger and Flow Cell Table 124 Heat Exchanger and Flow Cell Item Description Part Number Item Description Part Number 1 Heat Exchanger 01048-87305 5 Capillary OUT see flow cell 2 Screw M3 8mm lg 0515-0897 6 Union 0100-0900 3 Flow Cell STD see page 541 7 Clamp Union 79883-00502 Flow Cell High Pressure STD see page 542 8 Screw M2.5 8mm lg 0515-0922 Flow Cell High Pressure Micro see page 543 4 Capillary IN Figure 201 see flow cell Capillary Column/MWD (60 cm lg 01048-87302 0.17 mm i.d.) Heat Exchanger and Flow Cell Since 1992 with two welded ZDV 540 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Parts Information Flow Cell Parts (STD-SST) Flow Cell Parts (STD-SST) Table 125 Standard Flow Cell Item Description Part Number Item Description Part Number Flow cell SST 6 mm, 8 µl 79883-60051 5 Compression Washer 79883-28801 Flow cell SST 10 mm, 13 µl 79883-60052 6 Washer (pack of 10) 5062-8553 Cell Repair Kits see page 544 7 Window Screw 79883-22402 Capillary IN 0.17, 100 mm lg 79883-87303 8 Cell Clamp Assembly 79883-85001 Capillary OUT 0.17, 150 mm lg 79883-87304 1 Window Assembly consists of 3, 4, 5, 6, 7 Screw M2.5 x 4 mm lg (cell body) 0515-1056 Clamp Union 79883-00502 Screw M2.5 x 8 mm lg (clamp) 0515-0922 2 Cell Gasket see page 544 Wrench 4 mm for fittings 8710-1534 3 Window Quartz 1000-0488 Hex Key 6 mm for cell screw 8710-2023 4 Window Holder 79883-22301 Figure 202 Flow Cell Parts (STD-SST) Service Handbook for 1050 Series of HPLC Modules - 11/2001 541 DAD/MWD: Parts Information High Pressure Flow Cell Parts (HP-STD-SST) High Pressure Flow Cell Parts (HP-STD-SST) Table 126 High Pressure Flow Cell Item Description 1 Part Number Item Description Part Number High Pressure Flow Cell 79883-60054 5 Washer (pack of 10) 5062-8553 Cell Repair Kits see page 544 6 Window Screw SST 79883-22404 Cell IN 50 .17, 100 mm lg 79883-87303 Cell OUT 50 .17, 150 mm lg 79883-87304 Window Assembly consists of 2, 3, 4, 5, 6 2 Seal ring HP 79883-27101 Hex Key 6 mm for cell screw 8710-2023 3 Window Quartz HP 1000-0953 Wrench 4 mm for fittings 8710-1534 4 Compression Washer HP 79883-28802 Figure 203 High Pressure Flow Cell (HP-STD-SST) 542 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Parts Information High Pressure Flow Cell Parts (HP-Micro-SST) High Pressure Flow Cell Parts (HP-Micro-SST) Table 127 High Pressure Flow Cell Item Description Part Number Item Description Part Number Micro Flow Cell 1.7 µl 79883-60055 5 Washer (pack of 10) 5062-8553 Cell Repair Kits see page 544 6 Window Screw SST 79883-22404 1 Window Assembly consists of 2, 3, 4, 5, 6 Cell IN 50 .17, 100 mm lg 79883-87303 Cell IN .12, 100 mm lg 79883-87305 2 Seal ring HP 79883-27101 Cell OUT 50 .12, 370 mm lg 79883-87306 3 Window Quartz 1000-0953 Hex Key 6 mm for cell screw 8710-2023 4 Compression Washers HP 79883-28802 Wrench 4 mm for fittings 8710-1534 Figure 204 High Pressure Flow Cell (HP-Micro-SST)) Service Handbook for 1050 Series of HPLC Modules - 11/2001 543 DAD/MWD: Parts Information Cell Repair Kits Cell Repair Kits Table 128 Cell Repair Kits Description contains (Qty) Cell Repair Kit 79883-68701 Seal Kit Seal Kit 79883-68702 Cell Screw Kit 79883-68703 Cell Gasket (12) 79883-68702 Cell Screw Kit 79883-68703 Window Quartz (2) 1000-0488 Compression Washers (2) 79883-28801 Window Holder (2) 79883-22301 Window Screw (1) 79883-22402 Spring Washers (10) 5062-8553 Cell Kit High Pressure 544 Part Number 79883-68700 Window Quartz HP (1) 1000-0953 Spring Washers (10) 5062-8553 Seal ring HP (2) 79883-27101 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Parts Information Lamp Housing Lamp Housing Table 129 Figure 205 Lamp Housing # Description Part Number 1 Retaining Ring 0510-1219 2 Spring Compression 1460-2254 3 Aperture 79883-24601 4 Window 79880-28111 Lamp Housing Service Handbook for 1050 Series of HPLC Modules - 11/2001 545 DAD/MWD: Parts Information Upgrade Parts MWD to DAD Upgrade Parts MWD to DAD The following parts are required to upgrade a 1050 MWD (79854A) to 1050 DAD (G1306A). Table 130 1050 Upgrade Parts MWD to DAD Description Part Number Firmware Board FIM G1306-66524 Keyboard (plastics) 01048-60202 Installation Note see “Upgrade to from 79854A MWD to G1306A DAD” on page 528 546 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Parts Information Upgrade Parts MWD to Series II Optical Upgrade Parts MWD to Series II Optical The following parts are required to upgrade a 1050 MWD (79854A) to 1050 MWD Series II optical. Table 131 Upgrade Parts MWD to Series II Optical Description Part Number Optical Unit 79883-60024 Firmware Board FIM 01048-66504 * Slit assemblies as required see “Optical Unit” on page 538 Flow cell as required see Flow Cells Resistor for AQB board modification 220 Ohm 5% 2W 0698-3628 ** or AQB board (latest version) 01048-69543 * Only required, if firmware revision is < 3.1. Only required if AQB board does not have the resistor that is located between fuse F22 and the rear connector J1 (SN 01050-016). ** Service Handbook for 1050 Series of HPLC Modules - 11/2001 547 DAD/MWD: Parts Information List of Accessories List of Accessories The following list shows parts that were part of the STD Accessory Kit. Please order by item if required. Table 132 Accessories Description Part Number Hex Key for flow cell 8710-2023 Capillary Column/MWD 0.17 mm i.d. 800 mm lg 01048-87302 Crimp Terminals 0362-0321 Screw M3 6 mm lg 0515-0886 Tube Flexible 0.7 mm i.d. (re-order 5 m) 5062-2462 CONT CONN UTIL F 1251-3911 CONN UTIL 2PIN F 1251-4782 Fuse 2 A 250 V NTD 2110-0002 Fuse 3 A 2110-0003 Fuse 250 V 0.25 A NB 2110-0004 Ferrule 5041-2121 Gripper 5041-2122 Male 5041-2123 Buffer Disc 5041-2124 Wrench 5/16-1/4 8710-0510 Screwdriver POZI 1 PT 3 8710-0899 Hex Key 3 mm 8710-0911 Hex Key 6 mm for cell screw 8710-2023 548 Service Handbook for 1050 Series of HPLC Modules - 11/2001 24 24 DAD/MWD: Additional Information This chapter provides additional information about the 1050 Diode Array and Multiple Wavelength Detectors DAD/MWD: Additional Information This section gives the following informations: • Hardware changes • Firmware changes • Known Problems 550 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Additional Information Product History Product History The introduction of the 79854A Multiple Wavelength Detector was in 1988. The introduction of the G1306A Diode Array Detector was in 1993. The following hardware and firmware changes have been implemented. Hardware Changes Table 133 Hardware Changes Date Serial Number Change 1990 3016G.... Introduction of Series II optical Jul 1992 Introduction of new cell screw design for Series II flow cells. 6 mm hexagonal key instead of screw with slit. Nov 1992 Introduction of High Pressure Cell with 13 µl and 1.7 µl for 400 bar operation (for Series II). Oct 1993 3343G00938 Apr 1994 New AQB board, same for 79854A MWD, G1306A DAD and G1600A CE. Introduction of Fan Cover and new part number for fans Apr 1994 3414G00321 New Firmware 1.10 (see “Firmware Changes” on page 552). May 1994 3423G../3423A... Introduction of n-MOS optical units. Jul 1994 Change on ASC board (delay time of amplifier), revision D-3444. Dec 1995 DAD New Firmware 1.20 (see “Firmware Changes” on page 552). May 1997 DAD New Firmware 1.30 (see “Firmware Changes” on page 552). Service Handbook for 1050 Series of HPLC Modules - 11/2001 551 DAD/MWD: Additional Information Firmware Changes Firmware Changes Table 134 Table 135 DAD Firmware Revisions Revision Major Changes Comments 1.00 First official release for G1306A 1.10 Instrument checks for lamp overflow before WL calibration and returns an error message (RE3001) if lamp overflow occurs. Essential for optical used in Capillary Electrophoresis instruments. FIM board same in G1306A and G1600A (CE) 1.20 added fraction collection for G1600A same in G1306A and G1600A (CE) (CE) 1.30 for use with new ChemStation Software same in G1306A and G1600A (CE) MWD Firmware Revisions Revision Major Changes Comments 1.00 No GPIB communication First official release for 79854A 3.00 GPIB communication for HPLC ChemStation. Showed some GPIB communication problems. Should be replaced with revision 3.1 (01048-66504). 3.10 GPIB communication problems solved Replaced version 3.00 (01048-66504). 552 Service Handbook for 1050 Series of HPLC Modules - 11/2001 DAD/MWD: Additional Information Known Problems Known Problems Panic Errors Intermittent PANIC errors are mostly generated by spikes (disturbances) on the bus lines. A dynamic bus termination has been added to the FIM board to suppress the spikes and to reduce the possibility of this failure mode. All FIM boards with revision C and higher do have the dynamic bus termination installed (RC-network instead of R-network). In case of intermittent PANIC errors replace FIM boards (revision A or B) with the current version. Service Handbook for 1050 Series of HPLC Modules - 11/2001 553 DAD/MWD: Additional Information Known Problems 554 Service Handbook for 1050 Series of HPLC Modules - 11/2001 In This Book This manual contains technical information about the Agilent 1050 liquid chromatographs. This manual is available as electronic version (Adobe Acrobat Reader file) only. 1050 Series of HPLC Modules Service Handbook Variable Wavelength Detector (79853C) Copyright Agilent Technologies 2001 All rights reserved. Reproduction, adaption, or translation without prior written permission is prohibited, except as allowed under the copyright laws. Part No. NONE 11/2001 Printed in Germany Warranty IMPORTANT NOTE The information contained in this document is subject to change without notice. This version of the 1050 service manual includes all sections from the 01050-90102 edition 4 (1995). Agilent Technologies makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties or merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Agilent Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn Germany The series I opticals information (79854A MWD) and the 79853A VWD information has been removed (products went out of support during 2000). Part numbers have been updated as of 11/2001. Contact your local Agilent support office in case of part number issues or upgrades. The latest version of this manual is available as Adobe Acrobat Reader (PDF) version only and can be downloaded from the Agilent Technolgies web page www.agilent.com. 25 25 VWD: General Information This chapter provides general information about the 1050 Variable Wavelength Detectors VWD: General Information This chapter gives general information on • about this detector • repair policy • specifications 560 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: General Information About the Detector About the Detector The 1050 Variable Wavelength Detector (VWD) is a detector of the modular type liquid chromatograph 1050 Series. This is a standalone grating/photodiode type general purpose detector. The performance and features match the requirements of the routine analysis and QC/QA analysis. The 1050 VWD is a standard size detector of 1050 modular type LC series and can be build up with other LC modules, such as pump and automatic sampler. Since it is standalone type, it can be also used as an ordinary LC detector. It has a functional keyboard and 16-character fluorescent display which provides you easy operation. Versions vs. Support Periods (EOS) 79853A • The 79853A VWD was shipped between May 1988 and January 1992. The support with parts ended November 1, 2000. 79853C • The 79853C VWD replaced the model 79853A VWD in January 1992. The end of support (EOS) will be August 1, 2006 with all 1050 series HPLC modules. • The 79853C VWD got a redesigned optical unit (“D” enhanced optical, see “VWD: Enhanced Optical Unit Information” on page 705) that replaced the original “C” optical unit in June 1995. The end of support (EOS) for the “C” optical unit parts will be August 1, 2006 with all 1050 series HPLC modules. Service Handbook for 1050 Series of HPLC Modules - 11/2001 561 VWD: General Information Repair Policy Repair Policy The 1050 VWD is designed that you can access all components easily. You can recalibrate wavelength using control functions. Customers are able to maintain certain parts of the 1050 VWD see Operator’s Handbook. For details on repair policy refer to “Repair Policy” on page 38 in chapter 1050 Common Information. 562 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: General Information Specifications Specifications Table 136 Specifications of 79853C VWD Detection Type Double beam photometer. Noise < 1.5 x 10-5 AU peak-to-peak at 254 nm, flowing water at 1 ml/min, 1 second response time (10-90%), standard flow cell. Drift < 5 x 10-4 AU/hour at 254 nm after warm-up. Wavelength Range 190 - 600 nm, settable in 1 nm increments. Wavelength Accuracy ±2 nm. Wavelength Reproducibility ±0.3 nm. Bandwidth 6.5 nm. Linear Absorbance Range Better than 1% up to 1.2 AU using acetone at 265 nm. Response Time 0.25, 1 or 4 seconds (10-90%); user-selectable. Spectra Storage of 1 spectrum during run; scan rate 10 nm/sec; range from 190 to 600 nm, selectable. Post-run plotting speed from 1 to 50 nm/sec selectable; plotting of background-corrected spectrum. Light Source Deuterium lamp from 1090/40/50 DAD. Flow Cells Standard 14 µl volume, 8 mm pathlength cell with 40 bar (588 psi) pressure maximum. Optional micro, preparative, high-pressure cells are available. Display Single line, 16 character fluorescent display with real time display of operating parameters and/or absorbance. Control Integrated keyboard with function keys; parameter editing during run possible; keyboard lock; optional control by computer or 3396 Series II integrator. Service Handbook for 1050 Series of HPLC Modules - 11/2001 563 VWD: General Information Specifications Table 136 Specifications of 79853C VWD Parameters Wavelength, output range, response time, zero, offset, balance, spectrum acquisition. Diagnostic Aids Wavelength calibration check with Holmium oxide filter. Time-programs Time-programmable wavelength and output range; storage of up to 5 time-programs. Analog Output One output user-configurable as recorder or integrator. For recorder: 100 mV or 1 V output range from 0.001 to 4 AU, user-selectable; for integrator: 100 mV/2 AU full scale or 1 V/2 AU full scale, user-selectable. Communications START (input/output), STOP (input/output), READY (output), SHUTDOWN (output) for synchronization with other LC modules. Safety Aids Extensive diagnostics, error detection and display via front-panel LED’s. Leak detection, safe leak handling, leak output signal for shutdown pumping system. Low voltages in major maintenance areas. Environment Temperature range: 5 to 55°C Humidity: < 95% (non-condensing) Power Requirements Line voltage: 100-120 or 220-240 VAC ±10% Line frequency: 48-66 Hz Power consumption: 150 VA max. Dimensions Height: 133 mm ( 5.2 inch) Width: 325 mm (12.8 inch) Depth: 545 mm (21.5 inch) Weight: 14 kg ( 31 lb) 564 Service Handbook for 1050 Series of HPLC Modules - 11/2001 26 26 VWD: Hardware Information This chapter provides hardware information about the 1050 Variable Wavelength Detectors VWD: Hardware Information Overview N OT E The information in this chapter is based on the original optical unit (version “C”). In June 1995 this optical was replaced by the enhanced version “D” to overcome baseline stability problems in unstable environments. For details on this “D” version refer to section Enhanced Optical Unit Information “VWD: Enhanced Optical Unit Information” on page 705. Figure 206 on page 567 shows the block diagrams of the 1050 VWD 79853C. The main components are: Table 137 Main Components Overview Component Purpose Power Supply (DPS-A) provides all voltages within the instruments Detector Controller Board (DCB) controls power supply, grating stepper motor, cutoff filter, keyboard, display and GPIB interface. It processes the signals coming from the pre-amplifier boards (sample and reference), the information from the grating and filter position sensor, leak sensor, remote control lines and the GPIB interface. Optical Unit contains all optical parts Keyboard/Display entry and display of parameter GPIB Interface communication with external controllers via GPIB 566 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Hardware Information Overview Figure 206 Block Diagram of VWD Service Handbook for 1050 Series of HPLC Modules - 11/2001 567 VWD: Hardware Information Optical System Overview Optical System Overview Figure 207 shows the optical diagram of the 79853C VWD. The radiation from the deuterium lamp is focused on a spherical mirror (M1). The light beam passes then a plane mirror (M2) the cutoff filter, the entrance slit, a spherical mirror (M3), the grating, again a spherical mirror (M4), a beam splitter and the flow cell to the sample diode. The beam through the flow cell is absorbed depending on the solutions in the cell, where UV absorption takes place. The intensity is converted to an electrical signal by means of the sample photodiode. Part of the light is directed to the reference photodiode by the beam splitter to obtain reference signal for compensation of intensity fluctuation of the light source. A slit in front of the reference photodiode focusses the light. Wavelength selection is made by rotating the grating, which is driven directly by a stepper motor. This configuration allows fast change of the wavelength. The cutoff filter is moved into the lightpath above 370 nm to reduce higher order light. Figure 207 Light Path of Detector 568 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Hardware Information Leak Interface Assembly Leak Interface Assembly To route waste from a module standing above the 1050 VWD to a module below a leak interface can be installed at the detector. It is part of the accessory kit. Figure 208 Leak Interface Service Handbook for 1050 Series of HPLC Modules - 11/2001 569 VWD: Hardware Information Leak Sensor Assembly Leak Sensor Assembly A drain is located at the bottom of the cell compartment and can be led to the waste container or the 1050 waste handling system (the VWD has to stand on top of another module when the leak interface is not used). A leak sensor is located behind the front panel assembly (Figure 209). Solvent would cool the leak sensor (self heating thermistor). The resulting change in resistance, measured by comparators on the Detector Controller Board (DCB), would generate an error message and switch the deuterium lamp OFF. N OT E In the 1050 System remote mode the leak message will turn off the pump. Figure 209 Leak Sensor Assembly 570 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Hardware Information Fan Assemblies Fan Assemblies The instrument is equipped with two fans. On the 79853C VWD, the fans are of different type: HIGH type this fan is located close to the lamp housing and runs with a higher speed LOW type this fan is located at the rear under the GPIB interface and runs with a lower speed The fans are connected to +24 VDC on the DCB Board. Service Handbook for 1050 Series of HPLC Modules - 11/2001 571 VWD: Hardware Information Optical Unit Optical Unit N OT E The information in this chapter is based on the original optical unit (version “C”). In June 1995 this optical was replaced by the enhanced version “D” to overcome baseline stability problems in unstable environments. For details on this “D” version refer to section Enhanced Optical Unit Information “VWD: Enhanced Optical Unit Information” on page 705. The Optical Unit houses all parts, from the deuterium lamp to the photodiode pre-amplifiers. N OT E The repair level is component. The optical unit is also available as assembly. Figure 210 Optical Unit 572 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Hardware Information Optical Unit Flow Cells There are several flow cells available as stainless steel or as titanium version, see Table 138 on page 574. The flow cell (Figure 211) can be exchanged easily. No adjustments are necessary. After disassembling of the flow cell, gaskets and windows can be replaced (refer to section “Flow Cell Maintenance” on page 655). There are several kits set up with replacement parts like gaskets and windows, see “Standard Flow Cell “C” (SST/Ti)” on page 693 and the following pages. Figure 211 STD Flow Cell N OT E At the outlet of the flow cell a defined peek capillary (from the accessories must be connected to build up a certain back pressure (noise reduction). See “Standard Flow Cell “C” (SST/Ti)” on page 693 and the following pages for parts. Service Handbook for 1050 Series of HPLC Modules - 11/2001 573 VWD: Hardware Information Optical Unit Table 138 Flow Cell Data STD (SST) UHP MICRO (SST) (SST) STD (TI) PREP (TI) Maximum Pressure 40 400 40 40 40 bar Pathlength 8 8 5 8 VAR mm Volume 14 14 1 14 VAR µl Inlet i.d. 0.25 0.25 0.10 0.25 0.80 mm Inlet length 555 555 555 555 67 mm Outlet i.d. 0.25 0.25 0.25 0.25 0.80 mm Outlet length 67 67 67 67 100 mm Outer diameter 1/16 1/16 1/16 1/16 1/16 inch Used materials for SST flow cells: SST, quartz and PTFE or Polyimide HP cell Used materials for TI flow cells: N OT E TI, quartz and PTFE STD Standard Flow Cell HP High Pressure Flow Cell (replaced by UHP early 1993) UHP Ultra High-Pressure Flow Cell (replaces HP early 1993), see details on “Ultra High-Pressure Flow Cell” on page 575. PREP Variable Preparative Flow Cell with volume of 0.9, 1.8, 4.4 or 8.8 µl depending on which gasket is used. MICRO Semi Micro Flow Cell The gaskets, windows and rings are not compatible with the high pressure Cell (79853-60009 - OBSOLETE) that has been replaced by the ultra high pressure Cellflow cell (79853-60013). See “Ultra High Pressure Flow Cell (SST)” on page 697 for details. 574 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Hardware Information Optical Unit Table 139 Correction factors for 79853C flow cells Flow cell type Cell volume Part number Path length (nominal) Path length (actual) Correction factor Standard flow cell 14 µl 79853-60000 8 mm 8.00 ± 0.19 mm 8/8.05 Standard flow cell TI 14 µl 79853-60011 8 mm 8.00 ± 0.19 mm 8/8.00 Micro flow cell 1 µl 79853-60010 5 mm 5.00 ± 0.19 mm 5/5.00 Ultra High pressure flow cell 14 µl 79853-60013 8 mm 8.00 ± 0.19 mm 8/8.00 Ultra High-Pressure Flow Cell Typical applications of the high-pressure flow cells are: • Hyphenated systems (LC-MS) • Supercritical Fluid Chromatography (SFC) • Multidetector systems • Narrow-bore column applications The main difference between the standard and high-pressure flow cells is the design of the window assemblies. The high-pressure flow cells have different windows, seal ring and gaskets, see Figure 212. The seal rings support and hold the window and at the same time form the high-pressure seal. N OT E The gaskets, windows and rings are not compatible with the high pressure Cell (79853-60009 - OBSOLETE) that has been replaced by the ultra high pressure Cellflow cell (79853-60013). See “Ultra High Pressure Flow Cell (SST)” on page 697 for details. The following materials are in contact with solvents: Stainless steel (AISI 316), Quartz, Kapton® polyimide (Kapton is a registered trademark of DuPont). Recommended pH range: 2.3 to 9.5 Service Handbook for 1050 Series of HPLC Modules - 11/2001 575 VWD: Hardware Information Optical Unit Figure 212 Exploded Diagram of High-Pressure Flow Cell Deuterium Lamp On the 79853C VWD, the deuterium lamp (Figure 213) is the high intensity lamp (79883-60002), which is same as in the 1040/90/50 series Diode Array Detectors. The reduction of energy emission of the lamp (Figure 214 on page 577) is time and wavelength dependent and is significantly higher within the first days and for wavelengths in the ultra violet range compared to the visible range (change in transmission of lamp glass). Usually, the response maximum of the lamp is near 230 nm, but can be shifted to a higher wavelength for an aged lamp. It has no relevance for intensity degradation at other wavelengths. The deuterium lamp filament is heated only during the ignition phase. The deuterium lamp can be exchanged easily. The lamp needs no adjustments. 576 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Hardware Information Optical Unit Figure 213 Deuterium Lamp Figure 214 Intensity Degradation of Lamp (79883-60002) • Measured wavelength is 230 nm • initial intensity about 20% higer than 79880-60002 • decrease in intensity is less with use Service Handbook for 1050 Series of HPLC Modules - 11/2001 577 VWD: Hardware Information Optical Unit N OT E The lamp should be replaced only if the following two criterias are both fulfilled: Baseline Noise (with test cell) has increased significantly. Amount of counts of the lamp (with test cell) has decreased to less than 50% of the count record of this same lamp when newly installed). The decision to replace the lamp due to criterium 2 alone is not relevant, because the signal/noise may be still within instrument specifications. 578 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Hardware Information Optical Unit Photodiodes Assemblies Two photodiode assemblies (Figure 215) are installed in the optical unit. The sample diode assembly is located at the right side of the optical unit. The reference diode assembly is located in the front of the optical unit. N OT E Neither, the diodes nor the pre-amplifier boards are interchangeable. N OT E Refer to “Replacing Pre-amplifiers or Photodiodes” on page 667 for cleaning. Figure 215 Photodiode Assemblies sample diode reference diode Service Handbook for 1050 Series of HPLC Modules - 11/2001 579 VWD: Hardware Information Optical Unit Filter Assembly On the 79853C VWD (Figure 216), the Filter Assembly has a three filters [1] installed and is processor controlled. It can move into four positions: OPEN nothing in lightpath at wavelength < 370 nm CUTOFF cut off filter in lightpath at wavelength > 370 nm DARK 0 order calibration filter to reduce the light throughput to the photodiode during grating calibration at 0 order light HOLMIUM holmium filter for grating motor alignment A photo sensor [3] determines the correct position. N OT E Refer to “Replacing Filter Assembly Parts” on page 670 for cleaning. Figure 216 Filter Assembly 580 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Hardware Information Optical Unit Grating Assembly and Motor The Grating has 1200 lines/mm and is directly rotated by the Grating Drive Stepper Motor, depending on the wavelength entry. The whole range (190...600 nm) is equal to 1238 steps (15.5°). The step angle of the stepper motor rotation is 3.75° and is reduced to 1/300 by a gear mounted directly to the motor shaft. The stepper motor is controlled and driven by the Detector Controller Board (DCB). The stepper motor reference position is determined by a plate fitted on the motor shaft interrupting a beam of a photo sensor. The wavelength calibration of the grating is done at the 0 order light position and at at 656 nm, which is the emission line of the deuterium lamp. If the motor assembly has to be exchanged it is necessary to do a compensation of motor tolerances. Refer to “Replacing Grating Assembly Parts” on page 668. Figure 217 Grating Asembly N OT E The grating is coated with magnesium fluoride. The grating surface should not be touched or cleaned (see also “Replacing Grating Assembly Parts” on page 668). This will destroy the surface and reduce the light reflection. Service Handbook for 1050 Series of HPLC Modules - 11/2001 581 VWD: Hardware Information Optical Unit Mirrors The instrument contains four mirrors (M1, M2, M3, M4). Three of them are spherical type, one plane. On M2, M3 and M4 the beam height is adjustable. Mirror M3 and M4 are identical. N OT E The mirrors are coated with magnesium fluoride. They should not be touched or cleaned (see also “Replacing Mirrors, Beamsplitter and Slits” on page 670). This will destroy the surface and reduce the light reflection. Slit Assemblies The instrument has two slit assemblies. The first slit is located at the light entry into the main optical compartment and focused the light on mirror M3. The second slit is in front of the reference diode. Beam Splitter The beam splitter splits the light beam. One part goes directly to the sample diode. The reference diode gets the other part. The height of the light beam is adjustable. Refer to “Replacing Mirrors, Beamsplitter and Slits” on page 670 for cleaning. 582 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Hardware Information Enhanced Optical Unit (“D”) Enhanced Optical Unit (“D”) In June 1995 this original optical unit was replaced by the enhanced version “D” to overcome baseline stability problems in unstable environments. For details on this “D” version refer to section Enhanced Optical Unit Information “VWD: Enhanced Optical Unit Information” on page 705. Service Handbook for 1050 Series of HPLC Modules - 11/2001 583 VWD: Hardware Information Enhanced Optical Unit (“D”) 584 Service Handbook for 1050 Series of HPLC Modules - 11/2001 27 27 VWD: Electronic Information This chapter provides electronic information about the 1050 Variable Wavelength Detectors VWD: Electronic Information This chapter gives information about the electronic of the 1050 Variable Wavelength Detector: • Overview • Interconnection Diagram • Detector Controller Board (DCB) • Power Supply (DPS-A) • Keyboard/-electronics • Pre-amplifier Boards • Power Supply Connection Board (PSC) • GPIB Communication Interface 586 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Electronic Information Location of Electronic Assemblies Location of Electronic Assemblies In the 1050 VWD, the following electronic assemblies are available (for item numbers refer to Figure 218 on page 588): Table 140 Electronic Assemblies Item Description 1 GPIB Interface Firmware ROM GPIB 2 Fan Assembly (LOW) 3 Fan Assembly (HIGH) 4 Connection Board (PSC) 5 Deuterium Lamp Assembly 6 Sample Diode Assembly (SDA) 6 Pre-Amplifier Board SAMP 7 Display Interface Board (KDI) 7 Display Module (VFD) 8 Leak Sensor Assembly 9 Reference Diode Assembly (RDA) 9 Pre-Amplifier Board REF 10 Controller Board (DCB) 11 Firmware ROM DCB 12 Power Supply Assembly (DPS-A) Service Handbook for 1050 Series of HPLC Modules - 11/2001 587 VWD: Electronic Information Location of Electronic Assemblies Figure 218 Location of Electronic 588 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Electronic Information Interconnection Diagram Interconnection Diagram Figure 219 Interconnection Diagram Service Handbook for 1050 Series of HPLC Modules - 11/2001 589 VWD: Electronic Information Detector Controller Board (DCB) Detector Controller Board (DCB) Repair Level: EPROM and Board Table 141 Part Numbers for DCB tem Part Number Comment DCB (Exchange) 79853-69511 for use with PSC -66512 DCB 79853-66511 for use with PSC -66512 DCB 79853-66506 (OBSOLETE) for use with PSC -66509 (OBSOLETE) Firmware ROM DCB 79853-13005 N OT E If the DCB board is replaced by 79853-66511 version, the PSC board MUST be changed to 79853-66512. Main Functions The main functions of the Detector Controller Board (DCB) are: CPU signal processing display analog output digital input/output A/D conversion D/A conversion control of Optical Unit deuterium lamp ignition grating movement filter movement leak detector remote control 590 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Electronic Information Detector Controller Board (DCB) Figure 220 Block Diagram DCB Service Handbook for 1050 Series of HPLC Modules - 11/2001 591 VWD: Electronic Information Detector Controller Board (DCB) Digital Section CPU A 8-bit 1-chip Microprocessor 7810 is used as CPU. The 7810 includes 256 byte-RAM, 8 channel 8-bit A/D Converter, 16-bit timer/event counter, 2-channel 8-bit timer and two 8-bit I/O Ports. The Data Bus is 8-bit multiplexed with the address. ROM/RAM/EEPROM The ROM contains the firmware of the the detector and can be exchanged separately. In addition to the built-in functions, the 7810 has 64 Kbyte| of external memory address and 32 Kbyte-ROM, 8 Kbyte-SRAM and 2 Kbyte-EEPROM are added. The EEPROM contains: • the time program; • the grating calibration constant; • D/A converter calibration constant; • parameters set by key input (wavelength, range, response time, mode). Clock The main clock (24 MHz) is divided and distributed to: 24 MHz A/D Converter Count Pulse 12 MHz CPU Clock 6 MHz D/A Converter Count Pulse 3 MHz GPIB Controller, Key/Display Controller Clock 1.2 KHz A/D Converter Integration period After the power turns on, for about 100 ms the RESET signal is supplied to CPU, GPIB Controller and Key/Display controller. Also, anytime when power voltage becomes less than 4.7 V, the RESET signal is generated. The CPU controls directly the Buzzer and the Stepper Motor Driver to move the filters on the filter assembly. The stepper motor for the grating, the input and the output port are connected to the internal BUS (DATA ADDRESS and CONTROL) and are controlled by the CPU. The grating motor and the filter motor are driven by a motor controller IC and phase pattern are coming from CPU. 592 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Electronic Information Detector Controller Board (DCB) Figure 221 Block Diagram DCB - Digital Service Handbook for 1050 Series of HPLC Modules - 11/2001 593 VWD: Electronic Information Detector Controller Board (DCB) Analog Sections Signal Processing The light beam from the SAMPLE and REFERENCE enters the photodiode respectively. Its current output is converted into a voltage by pre-amplifier. The gain of the pre-amplifier can be changed into four stages with CPU control. The voltage signal from the pre-amplifiers are multiplexed and converted into digital form by a 18-bit A/D Converter. The conversion time of A/D Converter is 25 ms and is performed cyclically in the order of Zero Sample-Reference (Zero=GNDA) Electrically zero calibration is done while balancing. Digital data is transmitted to the CPU, digitally filtered based on response time and converted into the absorbance unit using the equation shown below: AU = log 10 ( REF ) – log 10 ( SAMP ) The input voltage range of the integrator is -0.5..+9.5 V. 594 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Electronic Information Detector Controller Board (DCB) Figure 222 Block Diagram DCB - A/D Conversion Service Handbook for 1050 Series of HPLC Modules - 11/2001 595 VWD: Electronic Information Detector Controller Board (DCB) A/D Converter Method for the A/D conversion is feedback type Pulse Width Modulation (PWM). Figure 223 A/D Converter Positive or negative reference voltage is alternately added to the integrator. Duty cycles of each reference voltage is controlled by the output of a comparator connected to the output of integrator. Input voltage (U1) is converted to pulse width so that sum of both reference voltages is balanced with the U1. Clock voltage and ±ES control this system and determines the period. The sum of clock voltage in one cycle is set to zero. Pulse width, which is proportional to input voltage U1, is counted and is converted into a digital output. The A/D converter has 18 bits resolution with 25 ms conversion time. D/A Converter D/A converter combines a Pulse Width Modulator (PWM) and a 12-bit DAC. The lower 4 bits of the DAC pulse width modulated with 12 bit resolution is added to the upper 8 bits of the DAC. The upper 8 bits are also modulated by fixed pulse width so that the lower 4 bits balances to LSB of the upper 8 bits (pulse width is 15/16). The lower 4 bits are scaled to each bit of the upper 8 bits when using 44:DAC CALIBRATION. The output of the 12-bit DAC is passed through a low-pass filter and 20-bit resolution analog signal is outputted to the BNC Connector. The cutoff frequency of a low-pass filter is set at 17 Hz while conversion frequency is 183 Hz. 596 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Electronic Information Detector Controller Board (DCB) Figure 224 D/A Conversion Signal Output The signal output is classified into three types: Display Out, Analog Out, Digital In/Out. Display Out The display module receives ASCII codes via Keyboard Interface Board via the Data Bus. On the Display Module, the ASCII code is converted to display code and gives output on fluorescent display with 5 x 7 dots and 16 characters. Signal (Analog) Out The Signal (Analog) Out is available at a BNC connector at the rear of the instrument. It is generated by 20-bit D/A converter. The conversion cycle of the D/A converter is about 5.5 ms. The output of the D/A converter is filtered by a low-pass filter. The output can be switched to: Full Scale Output Impedance 1V 1000 Ohm 0.1 V 100 Ohm Digital In/Out The digital signal is delivered to the GPIB Interface (option) via the Data Bus and is converted into an GPIB signal. Control of Deuterium Lamp The deuterium lamp is ignited using Anode Current, Trigger Voltage and Heater Voltage supplied from the Power Supply Unit. The ignition procedures are controlled by the CPU signal. The heater voltage is switched from 2.5 V during ignition to 0 V after ignition. Service Handbook for 1050 Series of HPLC Modules - 11/2001 597 VWD: Electronic Information Detector Controller Board (DCB) Control of Grating Assembly The wavelength is set by rotating the grating with a 2-phase stepper motor. The step angle of the stepper motor rotation (1 step angle 3.75°) and is reduced to 1/300 by a gear. The stepper motor is controlled and driven by DCB. The CPU contrls the motor controller IC that drives the motor. Stepper Motor reference position is determined by a plate fitted on the swing arm interrupting a beam of photo interrupter. The output signal of the photo interrupter is read by a 8-bit ADC of the CPU. Control of Filter Assembly The rotation of stepper motor controls the insertion of a diffterent filters into the light path (cutoff, holmium, light reduction). The stepper motor is controlled and driven by DCB. The CPU controls the motor controller IC that drives the motor. Remote Control The REMOTE connectors communicate start or stop, error and not ready signal inputs and outputs. For detailed description of remote control refer to the 1050 Service Handbook, chapter Common Information. N OT E When the 79853C VWD is used in a system which is connected via remote, the VWD should be switched on as first module. Otherwise it may influence other modules at power on. Leak Detection The leakage from a flow cell is detected by change of Thermal Radiation Constant of NTC thermistor. Wheatstone bridge is constructed from NTC thermistor and resistors on the DCB. Its supply voltage is varied by controlling 24 V-power with Switching Regulator controller. The supply voltage is controlled to keep the thermistor at about 150 Ohm (150°C) constantly. If leakage occurs and the thermistor is soaked in the leaked liquid, the thermal radiation constant are changed and gives higher supply voltage at both ends of wheatstone bridge. This change is read by the CPU and compensated with ambient temperature. Error condition is when LS > LL. The values are visable with 33:LEAK TEST. 598 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Electronic Information Detector Controller Board (DCB) Figure 225 Block Diagram - Leak Detection Change in Thermal Radiation Constant with surrounding temperature change is compensated by second NTC thermistor having same characteristics. Service Handbook for 1050 Series of HPLC Modules - 11/2001 599 VWD: Electronic Information Detector Controller Board (DCB) Figure 226 Board Layout DCB Table 142 Test Connector J16 Pin Purpose Pin Purpose Pin Purpose Pin Purpose Pin Purpose 5 1 Photocurrent 2 REF Photocurrent 3 SAMP +15 V 4 -15 V 6 +5 V A/D Clock 1.2 kHz Ref Voltage +10 V 9 Analog GND 10 600 7 8 Digital GND Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Electronic Information Power Supply (DPS-A) Power Supply (DPS-A) Repair Level: Fuses and Exchange DPS-A Table 143 Part Numbers for DPS-A Item Part Number DPS-A (Exchange) 01050-69375 DPS-A (New) 5061-3375 Fuse for 110 V operation 3 A 2110-0003 Fuse for 220 V operation 2 A 2110-0002 For detailed information on the power supply refer the 1050 Service Handbook, chapter 1050 Common Information. Lamp Ignition The heater output made by a series regulator is in the pre-heating status 2.5 V always. After ignition a different output voltage is selected depending on the lamp type used: In the 79853C VWD the heater is switched off after ignition. Service Handbook for 1050 Series of HPLC Modules - 11/2001 601 VWD: Electronic Information Keyboard Keyboard The flat keys at the front panel is composed of 6 x 4 matrix. Data is read by scanning at Key/Display Controller on the Keyboard Display Interface Board. Key entry is checked by reading the status of the controller by the CPU at every 10 ms. The Key/Display Controller also controls LED lamp lighting. Figure 227 Keyboard 602 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Electronic Information Keyboard Keyboard Electronics (KDI / VFD) Repair Level: Board Table 144 Part Numbers for Keyboard Electronics Item Part Number Keyboard Display Interface (KDI) 79853-66502 Display Module Board (VFD) 79853-66503 Behind the frontpanel two electronic boards are located: Keyboard Interface Board (KDI) and the Display Module Board (VFD). Keyboard Display Interface The Keyboard Interface Board (KDI) is connected to the DCB board and contains: • interface between key-matrix (6 x 4) and DATA bus • LED driver for the status messages ERROR, NOT READY, LAMP and RUN • buzzer. Display Module The Display Module Board (VFD) is connected to the KDI and contains: • CPU for control of latch driver • latch driver for the Vacuum Fluorescence Display (FLD) • DC/DC converter to provide the voltages for the FLD. Refer to “Replacing Display Boards” on page 662, when replacing this board. Service Handbook for 1050 Series of HPLC Modules - 11/2001 603 VWD: Electronic Information Keyboard Figure 228 Block Diagram of Keyboard Electronics 604 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Electronic Information Pre-Amplifier Boards Pre-Amplifier Boards Repair Level: Board Table 145 Part Numbers for Pre-Amplifiers Item Part Number Pre-Amplifier Board Sample 79853-66507 Pre-Amplifier Board Reference 79853-66508 Sensor Sample 79853-61109 Sensor Reference 79853-61110 The light (absorbtion) from the deuterium lamp (flow cell) is detected by the sample and the reference photodiode. Its current is then amplified by the pre-amplifiers. The signal then is routed to the DCB. The wires from the photodiodes are soldered onto the board. Figure 229 Photodiode Assemblies Sample Reference Service Handbook for 1050 Series of HPLC Modules - 11/2001 605 VWD: Electronic Information Power Supply Connection Board (PSC) Power Supply Connection Board (PSC) Repair Level: Board Table 146 N OT E Part Numbers for PSC Board Item Part Number PSC Board (for DCB -66511) 79853-66512 PSC Board (for DCB -66506 OBSOLETE) 79853-66509 OBSOLETE If the DCB board is replaced by 79853-66511 version, the PSC board MUST be changed to 79853-66512. This board connects the Power Supply DPS-A with the DCB and the Deuterium Lamp Assembly. The wires of the lamp cable are soldered in. Figure 230 Board Layout PSC 606 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Electronic Information GPIB Communication Interface GPIB Communication Interface Repair Level: Board, Firmware Table 147 Part Numbers for GPIB Interface Board Item Part Number GPIB Board (with cable) 79853-68711 GPIB Cable to DCB Board Firmware ROM GPIB 79853-13004 Parallel Interface Dual direction transceiver for data bus between master and slave CPU’s. 8 bit aux code from DCB to GPIB board. 3 bit control code from GPIB board to DCB Microprocessor Single chip microprocessor with 1 Mbyte address capability, 512 byte internal RAM and 32 I/O ports. Memories 32 Kbyte of ROM for program memory and 128 Kbyte RAM for the run buffer. Firmware Description The GPIB board performs all interruption processing from the GPIB controller. DCB and GPIB board communicate with hardware interrupts. Receiving GPIB commands the GPIB board passes them to the DCB with 3 bit control code. This control code shows the kind of bus data such as GPIB commands, error codes or requesting data code and whether the data ended or not. During run or monitor mode the DCB send chromatogram data immediately to the GPIB board with 8 bit aux code. This aux code shows the kind of bus data such as chromatogram data, parameters, time tables, remote line status or GPIB board control code and whether the data ended or not. The GPIB board writes the received data into the run buffer. The GPIB sends out the formatted data adding the start and the end record. GPIB Address Setting The GPIB address setting is done with a switch (1) at the rear of the GPIB board. The factory setting is ’10’ (position A). Service Handbook for 1050 Series of HPLC Modules - 11/2001 607 VWD: Electronic Information GPIB Communication Interface Figure 231 Location of GPIB board GPIB Firmware Revisions Refer to “GPIB ROM Firmware Revisions” on page 733 for information on firmware revisions. 608 Service Handbook for 1050 Series of HPLC Modules - 11/2001 28 28 VWD: Diagnostic & Troubleshooting Information This chapter provides information on error messages and diagnostic features of the 1050 Variable Wavelength Detectors VWD: Diagnostic & Troubleshooting Information This section provides information on the • diagnostic routines • error messages • user contol functions • service control functions 610 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Self Diagnosis Self Diagnosis At power on and after lamp ignition the instrument checks itself for correct operation. In case of malfunctions, error messages will inform the operator on the fault. During Power On The following tests are done automatically during power on. They are descibed on the next pages together with the error message: • Vaccuum Fluorescent display • ROM and RAM • Display • Leak sensor • Voltages • A/D Converter • EEROM Data • Grating Drive During Normal Operation The following tests are done automatically during normal operation: • for light intensity • for filter movement • for leaks Service Handbook for 1050 Series of HPLC Modules - 11/2001 611 VWD: Diagnostic & Troubleshooting Information Error Messages Before Lamp Ignition Error Messages Before Lamp Ignition Error messages may come up during the power on state or the normal operation. At Power ON During power on the instrument run automatically through different selftest routines. If all test are passed, the display shows HP 1050 VWD. While initializing the CPU checks the response of the Vaccuum Fluorescent Display (VFD) module. If there is no problem, SELF DIAGNOSIS IN PROGRESS is displayed. If there is no response from the VFD, the ERROR lamp will light, the buzzer is heard for 2 seconds and is halted. ❏ Check connection DCB/KDI and KDI/VFD module. ❏ Replace VFD Module. ❏ Replace KDI Board. ❏ Replace DCB Board. ❏ Replace DPS. ROM TEST FAILED The ROM Test calculates the checksum and compares it with a stored value. If a differrence is found, ERROR LED lights, ROM TEST FAILED is displayed and the CPU is halted. Otherwise ROM TEST OK is displayed. ❏ Replace EPROM. ❏ Replace DCB. RAM TEST FAILED During RAM Test, firstly every RAM address is uniformly written. Then in ascending order, each address is tested for contents and then the data is inverted and written. Then the same procedure is repeated in decending order with the inverted data. This cycle is repeated twice. If an error is found, RAM TEST FAILED is displayed and further operation is prohibited. Otherwise, RAM TEST OK is displayed. ❏ Replace DCB. 612 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Error Messages Before Lamp Ignition Display Test During Display Test every dot on the VFD module is set and you have to confirm it by yourself. If display is black or shows missing dots ❏ Check connection of flat ribbon cable DCB to KDI. ❏ Replace KDI. L.SENSOR TROUBLE The Leak Sensor Test checks the leak sensor and the leak sensor circuit, but not for a leak resulting from the cell. The voltage applied is measured using built-in 8 bit ADC (A/D Converter) of the CPU as well as temperature compensation voltage from a second thermistor. If the LS > LL, L.SENSOR TROUBLE is displayed. The range during turn on should be: LS:0.63..4.06 V and LL:2.82..4.00 V. ❏ Use 33:LEAK S.VOLT to verify the values, (see message LEAK DETECTED. ❏ Check connection of leak sensor to DCB. ❏ Replace leak sensor. ❏ Replace DCB. POWER FAILURE During Voltage Test this message is displayed if the voltages exceeds the tolerance. If a voltage is not correct, it is displayed for a short moment, for example +24V TROUBLE. ❏ Check voltages using function 34:VOLTAGE TEST: Table 148 DC Voltages Voltages Used for + 12 V (±1 V) filter and grating motor - 15 V, + 15 V (±1 V) analog circuits + 24 V (± 4.8V) leak sensor, fans ❏ Replace DCB. ❏ Replace Power Supply. Service Handbook for 1050 Series of HPLC Modules - 11/2001 613 VWD: Diagnostic & Troubleshooting Information Error Messages Before Lamp Ignition ADC TROUBLE During the A/D Converter Test the 18 bit ADC for photocurrent acquisition is tested with multiplexer channel fixed at analog ground. Pulse count for ground input is measured 20 times and calculate the average and the fluctuations. If the value exceeds the pre-determined value ADC TROUBLE is displayed. ❏ Replace DCB. EEROM DATA LOST During EEROM Data Test various parameters such as monochrometer parameter and time table are stored in EEROM (Electrically Erasable Read Only Memory) in order to save the value in absence of power. At initializing those values are checked using checksum. If an error is found, EEROM DATA LOST is displayed and default values are set. Different types of EEROM DATA LOST messages are possible: EEROM DATA LOST0 The key settable parameters (wavelength, responsetime, and so on) or time time tables are lost. They are replaced by default values. ❏ Re-enter the values. ❏ Replace DCB. EEROM DATA LOST1 Wavelength parameter (zero order) are lost. They are replaced by default values. The monochromater parameters are differrent for each instrument. ❏ Execute 20:0th CALIB. or enter the 0th order parameter directly using 31:SET WL PARAM. ❏ Execute 45:WL COMPENSATE. EEROM DATA LOST2 The DAC parameters are lost. The parameters are the scaling factors for each DAC bit and ZERO SPAN factors. The lost parameters are recoverable. ❏ Execute 44:DAC CALIB. EEROM DATA LOST3 The DAC parameters are lost. The parameters are the offset parameter of the ADC reading for the output of each DAC bit (used for DAC calibration). N OT E These parameters can be re-written at the factory only. ❏ Perform 41:DAC TEST. If OK, then leave it as it is. If NOT OK, then continue. 614 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Error Messages Before Lamp Ignition ❏ Perform 44:DAC CALIB. The default values of the offset parameters are taken now. ❏ Perform 41:DAC TEST. If OK, then leave it as it is. If NOT OK, then replace DCB board. WL SET TROUBLE During the initialization of the grating motor position, the motor moves backward to the home position where position sensor detects the limit. If it is not able to detect the limit, WL SET TROUBLE is displayed. ❏ Check connection of position sensor and grating drive motor. ❏ Switch OFF lamp, remove top cover of optical unit to observe movement of grating mirror (changing wavelength). If grating will not rotate after changing the wavelength, replace DCB or the Grating Driver Assy. ❏ Using 36:GRATING P.S. you can move the grating shaft automatically or stepwise by pressing the down/up key. Normally in the position of about -200 steps, the output voltage of the position sensor will change from LOW to HIGH, detecting the limit position. If the output voltage will never change, the position sensor is defective or the grating drive assembly has a problem and has to be replaced. Service Handbook for 1050 Series of HPLC Modules - 11/2001 615 VWD: Diagnostic & Troubleshooting Information Error Messages After Lamp Ignition Error Messages After Lamp Ignition LAMP ERROR ❏ Check connections of lamp connector, PSC board and DPS to DCB. ❏ Replace lamp, DPS, DCB. LOW ILLUMINATION Light intensity of deuterium lamp is checked after lamp ignition at the wavelength of 250 nm. If the reference voltage at 250 nm is < 0.6 V, the detector will check the reference voltage at 500 nm and if < 0.12 V, LOW ILLUMINATION will be displayed. In this case the detector will never return to the original wavelength. It will remain at 500 nm. This test is skipped if WL SET TROUBLE is displayed and unable to set the wavelength. ❏ Check the lamp image on the entrance slit. If the image does not cover the slit properly, adjust mirror M1. ❏ Check connection to pre-amplifiers. ❏ Replace the lamp for deterioration of lamp. ❏ Replace the mirrors M1 and M2 for deterioration of mirrors. FILTER ERROR During Filter Test the second order light cutoff filter is tested by inserting it at the wavelength of > 370 nm and measuring the change of light intensity. If an error is found FILTER ERROR is displayed. This message comes up if • The reference current at 220 nm is more than 2.00 and at 500 nm more than 1/16 of the value at 220 nm. Then the filter is always off. • The photocurrent at 220 nm is less than 2.00 and at 500 nm more than 0.04. Then the filter is always ON. • The reference light beam is focussed far from the reference diode. ❏ Flow cell should be clean and bubble free. ❏ Check connection of filter motor. ❏ Check correct operation of filter with 39:FILTER TEST and photo sensor of filter with 37:FILTER P.S. ❏ Check beam splitter alignment. 616 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Error Messages During Normal Operation Error Messages During Normal Operation LEAK DETECTED ❏ Enter service mode function 33:LEAK S. VOLT and check leak sensor voltages. Error condition is when LS > LL. The normal range should be: Table 149 Working Ranges for LS and LL LS signal LL signal 2.35..2.85 V 2.95..3.45 V ❏ If there is no leakage, check the connection leak sensor to DCB. ❏ Replace Leak Detector board. ❏ Replace Leak Sensor. DATA UNDERFLOW This message may come up only during BALANCING when the sample or referrence voltage is lower than 1 mV. ❏ Check, whether the flow cell is in correct position and the screws are tightened. ❏ Check the connection of pre-amplifier sample to DCB. ❏ Clean cell windows. ❏ Replace photo diode assembly. ❏ Replace DCB. DATA OVERFLOW This message may come up only during BALANCING when the sample or referrence voltage exceeds 9.4 V. Check, whether the flow cell is in correct position and the screws are tightened. Replace DCB. Service Handbook for 1050 Series of HPLC Modules - 11/2001 617 VWD: Diagnostic & Troubleshooting Information Error Messages During Normal Operation ADC OVERFLOW ❏ Execute BALANCE, so that the proper pre-amplifier gain is selected. ❏ Check, whether the flow cell is in correct position and the screws are tightened. ❏ Is apature gasket installed in flow cell? ❏ Replace DCB. No response for HPIB ❏ set address switch correct. ❏ check connection to DCB and GPIB cable. ❏ change GPIB board. 618 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Error Messages During Use of Control Functions Error Messages During Use of Control Functions CALIB FAILURE • When using 20:0th CALIB. this message may come up because the lamp is turned OFF or to much light reaches the sample diode. ❏ Turn On the lamp. ❏ Reduce light to sample diode. • When using 21:WL CALIBRATION this message may come up under the following reasons: If during scan the measured voltage of each step is the same (Figure 232-a), or is on an upslope (Figure 232-b) or is on a downslope (Figure 232-c). ❏ Use other wavelength setting to get a different range, 31:SET WL PARAM. ❏ Recalibrate grating with 21:WL CALIBRATION. Figure 232 Calibration Failure Service Handbook for 1050 Series of HPLC Modules - 11/2001 619 VWD: Diagnostic & Troubleshooting Information User Control Functions User Control Functions These functions are accessable for every instrument user. They are used for parameter settings and special operating functions during normal work. Table 150 User Control Functions # Display Used for 1 1:SAMPLE SCAN takes a sample scan 2 2:REF. SCAN takes a reference scan 3 3:SPECTRUM OUT plots the spectrum 4 4:SCAN FROM defines scan range from 5 5:SCAN TO defines scan range to 6 6:ZERO OFFSET zero offset in % 7 7:RESPONSETIME choices 0.25, 1 and 4 s 8 8:AUTO LAMPOFF automatic lamp off 9 9:AUTO LAMP ON automatic lamp on 10 10:OUTP. DEVICE integrator or recorder 11 11:OUTPUT VOLT 1 V or 100 mV 12 12:STATUS FW revision, errors or status 13 13:START MODE local, remote, hpsystem 14 14:OUTPUT CHECK checks the output voltage 15 15:RESET reset to default 16 16:PHOTOCURRENT sample and reference diode’s current 17 17:PARAM. LOCK locks certain parameters 18 18:WL SHIFT WL change on display 19 19:POLARITY polarity of signal (analog/GPIB) 20 20:0th CALIB. 0th order calibration 620 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information User Control Functions Table 150 User Control Functions # Display Used for 21 21:WL CALIBRATION 656 nm calibration 22 22:HOLMIUMCHECK WL Calibration check Functions 1 to 21 are described in detail in the User Documentation. Service Handbook for 1050 Series of HPLC Modules - 11/2001 621 VWD: Diagnostic & Troubleshooting Information Service Control Functions Service Control Functions N OT E These functions are secured by a PASSWORD, because they are normally used by trained Service Engineers. Misuse of certain function may result in a misalignment of the optical path or electronical values. If the VWD is in service mode, the ERROR status lamp blinks. If the instrument enters into this mode accidentally, the easiest way to abort from this mode is: TURN OFF the power off the instrument. Entering the Service Mode 1 Press [CTRL] [3] [0] [ENTER] 2 {30:SERVICE MODE} [ENTER] 3 {Pass Word} [1] [0] [5] [0] [ENTER] This control function is the entry point for all service control functions. You can enter service control function only through this control function. Select your desired control function using [DOWN] or [UP]. Once you abort from this mode, you have to execute this function again. However if power has not switched off since last entry, you can skip password by just pressing [ENTER]. It is adviced that you will turn-off the power, after you finished using service control functions to avoid the accidental entry to service control mode. In Table 151 on page 623 all service related functions are listed. Due to different firmware versions and improvements on 79853C VWD, the order of the functions is different. 622 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions The functions 20, 21 and 22 are part of the User Functions, but they are described in this section. Table 151 C A UT I O N Service Control Functions # Display Used for 20 20:0th CALIB. Zero Order calibration 21 21:WL CALIBRATION 656 nm calibration 22 22:HOLMIUMCHECK Wavelength Calibration check 31 31:SET WL PARAM. Parameter Set for Zero Order and 656 nm 32 32:FIX SIGNAL Fixed voltage to sample or reference path 33 33:LEAK S. VOLT Shows leak sensor voltages 34 34:VOLTAGE TEST Shows DC Voltages 35 35:ADC NOISE Check of ADC noise 36 36:GRATING P.S. Check of Grating Sensor 37 37:FILTER P.S. Check of Filter Sensor 38 38:REMOTE TEST Check of Remote lines- 39 39:FILTER CHECK Checks movement of Filter 40 40:0TH TEST OFF Positions the Zero Order Beam 41 41:DAC TEST Checks DAC 42 42:PREAMP GAIN Checks linearity of gains 43 43:EEROM TEST Checks EEROM data 44 44:DAC CALIB . Calibrates the DAC 45 45:WL COMPENSATE Compensates non-lineraties of grating Important parameters might be lost. DO NOT use control functions 31 through 45 until you have read this paragraph and fully understand the functions and result of operation. Some functions may change the monochrometer parameters and misuse of these functions leads to inaccurate wavelength setting. Service Handbook for 1050 Series of HPLC Modules - 11/2001 623 VWD: Diagnostic & Troubleshooting Information Service Control Functions Zero Order Calibration 20:0th CALIB. This control function is used for the electrical calibration of the zero order beam of the monochrometer. The step number corresponds to the number in 31:SET WL PARAM. The grating is driven by the stepper motor through steps 150 to 250 searching for a maximum. The step number with the maximum voltage is displayed, and if accepted, written into the EEROM. The intensity of the zero order light is reduced by inserting a filter in the calibration position automatically. Prior to the use of this function, the grating assembly should be pre-aligned on the zero order light, using control function 40:0TH TEST OFF. Table 152 Control Function: Zero Order Calibration Key Operation ENTER Display Description 20:0th CALIB. Select function. nn step CHANGE? display current parameter or change to 200. ENTER or to continue calibration or CLEAR to abort. wait appr. 20 seconds. nn step x.xxxV starts the calibration scan from 150 step to 250step No key entry is allowed here. Possible error message at this point may be: 624 CALIB. FAILURE Indicates that the lamp is OFF. DATA OVERFLOW Indicates that too much light reaches the sample photo diode. Reduce light and insert paper between cell and sample diode Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions Table 152 Control Function: Zero Order Calibration Key Operation Display Description DATA UNDERFLOW Indicates that not enough light reaches the sample photo diode. Check light path. The next line will be shown, if no error message occured. ENTER nn step y.yyyV Displays the step that gave the maximum light intensity. nnn step OK ? Promps for confirmation, to change the parameter. ENTER Takes the displayed step number. CLEAR Rejects the displayed step number. ENTER nnn step New parameter is written in EEROM and monochrometer is reset with new parameter. 20:0th CALIB. End of Zero order beam calibration. You may repeat the procedure again. Service Handbook for 1050 Series of HPLC Modules - 11/2001 625 VWD: Diagnostic & Troubleshooting Information Service Control Functions Wavelength Calibration 21:WL CALIBRATION This control function is used for the calibration of the monochrometer using the 656 nm line emission from the deuterium lamp. The step number appeared in this control function is the number of steps of stepper motor from the 0 order beam to the 656 nm emission line. Maximum light intensity is searched between ±50 steps of 656 nm value. If the maximum peak is found, the step number is written into EEROM and corresponds to the value in 31:SET WL PARAM. Table 153 Control Function: WL Calibration Key Operation ENTER Display Description 21:WL CALIBRATION Select function. 656nm xxxx step Displays the wavelength for calibration and steps based on present PARAM.WL 656. ENTER or To continue calibration or CLEAR to abort. Wait appr. 30 seconds. xxxxstep y.yyyV Starts the calibration scan from 656 nm ±50 steps and seeks for maximum light intensity. No key entry is allowed here. Possible error message at this point may be: CALIB. FAILURE Indicates that there was no maximum found (see “CALIB FAILURE” on page 619). DATA UNDERFLOW Indicates that not enough light reaches the sample photodiode (<30 mV). The next line will be shown, if no error message occured. 626 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions Table 153 Control Function: WL Calibration Key Operation Display Description xxxxstep y.yyyV Displays the step that gave the maximum light intensity. ENTER 656nm xxxx step Displays the wavelength and step that gave the maximum light intensity. after 2 seconds 656nm xxxxstep Displays the new parameter at 546 nm and prompts the confirmation. ENTER Takes the displayed step number. CLEAR Rejects the displayed step ENTER 656 yyyystepOK New parameter is written in EEROM and monochrometer is reset with new parameter. after 2 seconds 21:WL CALIBRATION End of calibration. You can repeat the procedure again. Service Handbook for 1050 Series of HPLC Modules - 11/2001 627 VWD: Diagnostic & Troubleshooting Information Service Control Functions Wavelength Calibration Check 22:HOLMIUMCHECK This control function is used for the automatic check of the instruments WL calibrations using the some specific lines on the Holmium oxide filter which is moved into the light path. Table 154 Control Function: HOLMIUMCHECK Key Operation ENTER Display Description 22:HOLMIUMCHECK Select function. CHECK? CLEAR to leave function. ENTER to start the calibration check. 360.8nm automatic verification 418.5nm automatic verification 536.4nm automatic verification HOLMIUM CHECK OK if within specification CLEAR to leave function. DOWN 360.8nm 360.7nm displays measured value DOWN 418.5nm 418.4nm displays measured value DOWN 536.4nm 536.4nm displays measured value CLEAR 22:HOLMIUMCHECK to leave function. If this test was not successful, perform 20:0th CALIB. and 21:WL CALIBRATION. 628 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions SET WL Parameter 31:SET WL PARAM. This control function is used for the confirmation of monochrometer parameters or for changing them directly. PARM.WL0 is the number of steps of stepper motor from the position sensor, while PARM.WL656 is the number of steps from 0 order beam. As these values changes slightly from instrument to instrument, they are originally calibrated and written into EEROM. The parameter 360.8 nm, 418.5 nm, 486 nm and 536.4 nm cannot be changed. These four parameters set with 45:COMPENSATE are used to compensate non-linearity of the grating drive. If PARM.WL656 is changed, these four parameters are automatically shifted. Table 155 Control Function: SET WL PARAM. Key Operation ENTER Display Description 31:SET WL PARAM. Select function. Parm.WL0 200 Displays the 0 order light parameter (same value found with 20:0th CALIB. . UP Select the parameter WL656 nm. Parm. 656yyyy Displays the step number at 656 nm (same value found with 21:WL CALIBRATION. Enter the parameter using numeric keys. UP Parm.360.8yyyy Displays the step number at 360.8 nm. UP Parm.418.5yyyy Displays the step number at 418.5 nm. UP Parm. 486 yyyy Displays the step number at 486 nm. UP Parm.536.4yyyy Displays the step number at 536.4 nm. Service Handbook for 1050 Series of HPLC Modules - 11/2001 629 VWD: Diagnostic & Troubleshooting Information Service Control Functions Table 155 Control Function: SET WL PARAM. Key Operation Display Description ENTER 31:SET WL PARAM. Control function is displayed again. CLEAR On WL0 or WL656 parameter, reenters the displyed value. In order to change both parameters you have to repeat the above procedure for both wavelengths. 630 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions Fix Signal 32:FIX SIGNAL If the 1050 VWD shows noise or drift problems, this function can help to isolate the cause. The reference or the sample diode can be set to an fixed electrical value to remove influences from the light path. This function can also be used to retrieve the instrument profile of the instrument. Table 156 Control Function: FIX SIGNAL Key Operation ENTER Display Description 32:FIX SIGNAL Select function. REF. CH. FIXED The photocurrent of reference photo diode is a fixed electrical value. DOWN or UP ENTER N OT E Select the parameter. NORMAL-NOT FIXED Return to normal condition (neither photocurrrent is fixed.) SMP. CH. FIXED The photocurrent of sample photo diode is a fixed value. 32:FIX SIGNAL Control function is displayed again. If either channel is fixed, the ERROR status lamp is blinking even after returning to analysis mode from service control mode. This is an alarm to show that the instrument is abnormal condition. You can return to normal condition by executing NORMAL-NOT FIXED or switching off the power. Service Handbook for 1050 Series of HPLC Modules - 11/2001 631 VWD: Diagnostic & Troubleshooting Information Service Control Functions Use of FIX SIGNAL Use this function for ❏ checking the noise of both sides separately; ❏ taking the instrument profile of both sides separately. With fixed signal, either the reference or the sample side is supplied with a constant current. So influences from the lamp effects only that side which is not fixed. Influence due to a drifting or defective photo diode effects both, a scan and the signal (noise). Small wavelength variations between fixed sample and reference scans are caused by the characteristics of the photo diodes. Noise with Reference Signal Fixed: If the noise is large, the problem may be caused by light path, flow cell or sample diode/pre-amplifier. Noise with Sample Signal Fixed: If the noise is large, the problem may be caused by light path, lamp or reference diode/pre-amplifier. To take an instrument profile proceed as follows: ❏ Enter 32:FIX SIGNAL and set SMP. CH. FIXED . ❏ Press [ENTER] and leave function. ❏ Press [BALANCE]. ❏ Take a reference scan 2:REF SCAN . ❏ Take a sample scan 1:SAMPLE SCAN . ❏ Set integrator to ATTN9, CS10 and Zero10%. ❏ Press [BALANCE]. ❏ Enter 3:SPECTRUM OUT , press [ENTER] [ENTER]. ❏ Start plot on integrator and press [ENTER]. The intensity profile is now plotted on the integrator. ❏ Perform above steps with REF. CH. FIXED to check the light through put of the cell. Figure 233 on page 633 shows both plots. 632 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions Figure 233 Example of Intensity Profiles Service Handbook for 1050 Series of HPLC Modules - 11/2001 633 VWD: Diagnostic & Troubleshooting Information Service Control Functions Leak Sensor Voltage 33:LEAK S.VOLT You can check the leak sensor with this contol function in case of trouble. Table 157 Control Function: Leak Sensor Voltage Key Operation Display Description 33:LEAK S.VOLT Select function. ENTER LS:2.70 LL:3.30 Displays LS (Leak Sensor Voltage) and LL (Temperature compensation voltage). Error condition is when LS > LL. The normal ranges are: LS signal 2.35..2.85 V, LL signal 2.95..3.45 V CLEAR 33:LEAK S.VOLT Leaves function. 634 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions Voltage Test 34:VOLTAGE TEST You can check some (but not all) voltages with this contol function. Table 158 Control Function: Voltage Test Key Operation Table 159 Display Description 34:VOLTAGE TEST Select function. ENTER 15.0 22.9 Displays first set of voltages. DOWN or UP 12.1 -15.0 Displays second set of voltages. CLEAR 34:VOLTAGE TEST Leaves function. DC Voltages Voltages Used for + 12 V (±1 V) filter and grating motor - 15 V, + 15 V (±1 V) analog circuits + 24 V (± 4.8V) leak sensor, fans Service Handbook for 1050 Series of HPLC Modules - 11/2001 635 VWD: Diagnostic & Troubleshooting Information Service Control Functions ADC Noise 35:ADC NOISE The output signal of the ADC noise corresponds to 196 AD counts at the Analog Output with 1 V full scale setting. The ADC noise must be within ±10 counts (±50 mV) over a time of 10 minutes (Figure 234). Table 160 Control Function: ADC Noise Key Operation Figure 234 Display Description 35:ADC NOISE Select function. ENTER TESTING ADC ADC noise is outputted. Start plotter in ATTN 7, ZERO 50, Chartspeed 1 (on HP 339X) CLEAR 35:ADC NOISE Leaves function. ADC Noise 636 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions Grating Photo Sensor 36:GRATING P.S. This control function can be used to check the function of the photo sensor and the drive mechanism of the grating. The movement of the grating can be done automatically or step for step. It will provide the step number and the voltage of photo sensor which detects the backward limit when the drive mechanism moves into the photo sensor. The photo sensor voltage exceeds 3 V when the photo sensor reaches at backward limit position. A normal step value for change from LOW to HIGH is around -200 steps. Table 161 Control Function: Grating Photo Sensor Key Operation Display Description 36:GRATING P.S. Select function. ENTER STPxxx PS0.11 Present step of stepper motor and photo sensor voltage is displayed. DOWN or UP STPxxx PSy.yy You can move the stepper motor and observe the voltage. ENTER STP-nnn PS3.90 Starts automatically the search for the home position and displays the step number (nnn) and the corresponding voltage. CLEAR 36:GRATING P.S. Leaves function. Service Handbook for 1050 Series of HPLC Modules - 11/2001 637 VWD: Diagnostic & Troubleshooting Information Service Control Functions Filter Photo Sensor 37:FILTER P.S. This control function can be used to check the function of the photosensor and the filter motor. The movement is done step for step. It will provide the step number and the voltage of photo sensor when the drive mechanism moves into the photo sensor. Table 162 Control Function: Filter Photo Sensor Key Operation Display Description 37:FILTER P.S. Select function. ENTER STP0 PS4.98 Move to home position and shows steps and photo sensor voltage. DOWN or UP STPxxx PSy.yy You can move the stepper motor and observe the voltage. When the motor leaves the photo sensor, then PS changes to 0.01. CLEAR 37:FILTER P.S. Leaves function. Pressing UP once rotates the filter 1 step (7.5°) to the left. DOWN once rotates the filter 1 step (7.5° to the right. 638 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions Remote Test 38:REMOTE TEST This control function is to test the remote control line. Disconnect the remote cables to avoid interferrence to and from other instruments. Remote lines tested are: START, SHUT DOWN, POWER DOWN, READY and STOP. PREPARE and START REQUEST are not tested. Table 163 Control Function: REMOTE Test Key Operation Display Description 38:REMOTE TEST Select function. ENTER Disconnect REMOTE Cable and Press START START REMOTE LINE TEST The REMOTE LINE TEST starts. REMOTE LINE OK When test is passed. REMOTE FAILURE There’s a trouble. 38:REMOTE TEST Leaves function. CLEAR Service Handbook for 1050 Series of HPLC Modules - 11/2001 639 VWD: Diagnostic & Troubleshooting Information Service Control Functions Filter Check 39:FILTER CHECK This control function is used to check the motion of second order cutoff filter. The cutoff filter returns to original position at the end of this control function. Table 164 Control Function: Filter Test Key Operation Display Description 39:FILTER CHECK Select function. ENTER CUT FILTER OFF Displays present filter status. DOWN or UP CUT FILTER ON Cutoff Filter moves in or out. CLEAR 39:FILTER CHECK Leaves function. 640 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions Zero Order Test 40:0TH TEST OFF This control function is used to move the stepper motor into the zero order position and has to be performed during the alignment of the grating. Table 165 Control Function: Zero Order Test Key Operation Display Description 40:0TH TEST OFF Select function. The test is still off and the grating is on set parameter wavelength. ENTER 0th STEP NOnnn Take the number of steps from 31:SET WL PARM. , (default) or use 200 steps. ENTER 0TH TEST ON The stepper motor is moved to zero order position. CLEAR 40:0TH TEST OFF Leaves function and grating is turned to set wavelength. Service Handbook for 1050 Series of HPLC Modules - 11/2001 641 VWD: Diagnostic & Troubleshooting Information Service Control Functions DAC Test 41:DAC TEST This control function is used to check the D/A converter by setting different bits. An AC voltage is added to the DC output and should be < 0.8 x 10-5 AU. Table 166 Control Function: DAC Test Key Operation Table 167 Display Description 41:DAC TEST Select function. ENTER TESTING BIT 0 Bit 0 is tested. UP TESTING BIT 1 Bit 1 is tested. UP TESTING BIT 2 Bit 2 is tested. UP TESTING BIT 3 Bit 3 is tested. UP TESTING BIT 4 Bit 4 is tested. UP TESTING BIT 5 Bit 5 is tested. UP TESTING BIT 6 Bit 6 is tested. UP TESTING BIT 7 Bit 7 is tested. CLEAR 41:DAC TEST Leaves function. DAC DC Values Bit mV Decription 0 27 1 32 jump of 5 mV 2 42 jump of 10 mV 3 62 jump of 20 mV 4 104 jump of 40 mV 5 22 GND plus offset voltage 6 185 jump of 80 mV 7 511 about half of maximum output voltage If you do not see a linear response, replace the DCB board. 642 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions An AC voltage is added to the DC output and should be < 0.8 x 10-5 AU. Figure 235 DAC Test Bit 0 (AC) Figure 236 DAC Test Bit 7 (AC) If one or more tested bits are out of limit, then perform 44:DAC CALIB. Service Handbook for 1050 Series of HPLC Modules - 11/2001 643 VWD: Diagnostic & Troubleshooting Information Service Control Functions Pre-amplifier Gain 42:PREAMP GAIN This control function allows the check of gain switching on the DCB. The gain can be switched to 1, 2, 4 and 8. Table 168 Control Function: Pre-Amplifier Gain Key Operation Display Description Change wavelength to 500 nm to reduce intensity of light. 42:PREAMP GAIN Select function. ENTER G1 R0.115 S0.045 Shows the photocurrent of reference and sample side with gain 1. DOWN G2 R0.227 S0.089 Shows the photocurrent of reference and sample side with gain 2. DOWN G4 R0.455 S0.179 Shows the photocurrent of reference and sample side with gain 4. DOWN G8 R0.914 S0.358 Shows the photocurrent of reference and sample side with gain 8. The displayed values should double each time. If not, change wavelength to 500 nm or change DCB. CLEAR 42:PREAMP GAIN Leaves function. 644 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions EEROM Test 43:EEROM TEST This control function checks the EEROM and is used as factory test. Table 169 Control Function: EEROM Test Key Operation ENTER CLEAR Display Description 43:EEROM TEST Select function. EEROM TEST****** The blinking * indicates the checked section. EEROM TEST OK Test was successful. If test failes, replace DCB. 43:EEROM TEST Leaves function. Service Handbook for 1050 Series of HPLC Modules - 11/2001 645 VWD: Diagnostic & Troubleshooting Information Service Control Functions DAC Calibration 44:DAC CALIB. This control function does a scaling between lower 12 bits and upper 8 bits of DAC and an automatic recalibration of the DAC internal voltages. It should be performed when the noise is higher than expected and a DAC non-linearity is found. The test runs automatically. The initial calibration is done at the factory. The lamp can be off, but the instrument should be on for some time for stabilizing the instrument to reduce drift. Table 170 Control Function: DAC Calibration Key Operation Display Description 44:DAC CALIB. Select function. ENTER Disconnect SIGNAL Cable and Press START START DAC SCALING Scaling starts. SCALING 0 Step 0 of 7 is displayed. f0 yyyy pre-scaling done for step 0. Now you steps 1 to 7 are done. ENTER CLEAR 646 DAC CALIB. OK Calibration was successful. 44:DAC CALIB. Takes new factors and leaves function. DAC CALIB.FAILED Calibration was not successful. 44:DAC CALIB. Keeps previous factors when calibratio failed and leaves function. Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Diagnostic & Troubleshooting Information Service Control Functions Wavelength Compensation 45:WL COMPENSATE This control function is used to compensate non-lineratity of the grating drive. N OT E If the grating motor or the grating has been replaced or moved, this function MUST be executed. During this test, the flow cell should be empty (no windows) or clean filled with water or methanol (no air bubbles). Absorption in the flow cell causes an error. • First step is to search for the 656 nm line emission of the deuterium lamp within a window of ±50 steps. • Then the processor sets the ideal (linear) steps for four interpolative points, 360.8 nm, 418.5 nm, 486 nm and 536.4 nm. 360.8 nm and 418.5 nm are absorption points of the holmium oxide spectra. 536.4 nm is a line emission from the deuterium lamp. • Next, it scans each ideal interpolative point (±25 steps) as reference. • Then the holmium oxide filter is inserted and it scans again for the three absorption points of holmium oxide spectra (±25 steps). • If all found values are in limit, then the parameters are written into EEROM (visable with 31:SET WL PARAM.). Table 171 Control Function: WL Compenstation Key Operation ENTER Display Description 45:WL COMPENSATE Select function. PARAM. CHANGE ? ENTER to continue calibration CLEAR to abort calibration XXXstep y.yyyV displays steps and voltage during calibration CALIB. FINISHED new parameter, written into EEROM. Service Handbook for 1050 Series of HPLC Modules - 11/2001 647 VWD: Diagnostic & Troubleshooting Information Service Control Functions Table 171 Control Function: WL Compenstation Key Operation Display Description ENTER 45:WL COMPENSATE Takes new factors and leaves function. WL CALIB. FAILURE one or more peaks could not be found with ±25 steps. Parameters are set to previous values. 45:WL COMPENSATE Keeps previous factors when calibration failed and leaves function. CLEAR 648 Service Handbook for 1050 Series of HPLC Modules - 11/2001 29 29 VWD: Maintenance Information This chapter provides provide procedures for service and maintenance of the 1050 Variable Wavelength Detectors VWD: Maintenance Information N OT E The information in this chapter is based on the original optical unit (version “C”). In June 1995 this optical was replaced by the enhanced version “D” to overcome baseline stability problems in unstable environments. For details on this “D” version refer to section Enhanced Optical Unit Information “VWD: Enhanced Optical Unit Information” on page 705. Warnings WA R N I N G Dangerous voltage is present in the cabinet, though it is covered and insulated. DO NOT TOUCH PARTS unless they are specified in the procedure. Be careful when you have to work in the optical unit. The lamp housing is hot. Be sure to wear a pair of safety or sun glasses. Since the deuterium lamp emits intensive ultraviolet light, it is dangerous to perform optical alignment without eye protection. Be careful not to expose your eyes directly to the light coming from the lamp. 650 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Securing for Transport Securing for Transport Figure 237 Securing for Transport Service Handbook for 1050 Series of HPLC Modules - 11/2001 651 VWD: Maintenance Information Replacement of Deuterium Lamp Replacement of Deuterium Lamp If the Deuterium lamp no longer ignites or the lamp emission has become too low and noisy, the lamp has to be replaced. The deuterium lamp is exchangeable by the user. No adjustment is necessary. For accurate wavelength setting excute user control function 20:0th CALIB. and 21:WLCalibration after exchanging the lamp. Step 1: Replacement ❏ Turn the lamp off. ❏ Loosen the two screws at the rear of the instrument which fix the cover and remove them. ❏ Remove top cover. ❏ Unplug the lamp and remove it. ❏ Exchange the lamp (no adjustment is required). ❏ Reconnect the lamp. ❏ Replace top cover. ❏ Turn the lamp on. 652 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Replacement of Deuterium Lamp Step 2: 0th Order Calibration The instrument scans for the maximum of the zero-order light. During 0th order calibration a filter for reducing light intensity to prevent ADC data overflow will be inserted automatically. Select control function 20:0th CALIB. [ENTER] enters function 200step CHANGE? displays the current parameter [ENTER] or [CLEAR] to continue or to abort 150step 0.000V instrument scans now for maximum from step 150 to 250 201step X.XXXV maximum when calibration successfully finished, press [ENTER] 201 step OK ? press [ENTER] to keep the new value and to leave function If CALIB. FAILURE occurs, press [CLEAR] to keep the old value and to leave function. Service Handbook for 1050 Series of HPLC Modules - 11/2001 653 VWD: Maintenance Information Replacement of Deuterium Lamp Step 3: WL CALIBRATION The instrument scans for maximum light intensity of 656 nm line spectrum of deuterium lamp. Enter control function 21:WL CALIBRATION. [ENTER] enters function 656nm 1900step displays the current parameter. [ENTER] or [CLEAR] to continue or to abort 1875step 0.000V the instrument scans now for for maximum for 100 steps 1902step X.XXXV maximum when calibration successfully finished, press [ENTER] 656 1902stepOK? press [ENTER] to keep the new value and to leave function. If CALIB. FAILURE occurs, press [CLEAR] to keep the old value and to leave function. 654 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Flow Cell Maintenance Flow Cell Maintenance To replace or clean certain parts of the flow cell you should have a clean working area. Refer to “Standard Flow Cell “C” (SST/Ti)” on page 693 and the following pages for detailed flow cell schematics. Flow Cell Maintenance Kits There are several maintenance kits available with replacement parts for the flow cells. For details see“Standard Flow Cell “C” (SST/Ti)” on page 693 and the following pages. Replacing Cell Parts For the detailed procedures refer to the Operating Manual. ❏ Remove flow cell. ❏ Unscrew the cell screw using a 6 mm hexagon wrench, see Figure 238 on page 656, item 1. ❏ Remove inner parts carefully and place them in the correct order in front of you. ❏ Replace window, gaskets or other parts as needed. N OT E Once a gasket has been compressed or spoiled on the surface, DO NOT use it again. A used gasket may cause leakage. ❏ Insert all parts in the correct order. ❏ Tighten the cell screw. ❏ Perform a “Leak Test” on page 657. Service Handbook for 1050 Series of HPLC Modules - 11/2001 655 VWD: Maintenance Information Flow Cell Maintenance Figure 238 Standard Flow Cell Flushing Procedure Cleaning the cell (by using a glass syringe!) ❏ Flush with iso-Propanol. ❏ Flush with bidistilled water. ❏ Flush with nitric acid : water (5 : 95). ❏ Flush with bidistilled water. ❏ Flush with iso-Propanol C A UT I O N This concentration of nitric acide is dangerous and proper attention to safety should be given. Also, the nitric acid flushing procedure is not a certain cure for a dirty cell. It is to be used as a last attempt to salvage the cell before certain cell parts have to be replaced. 656 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Flow Cell Maintenance Leak Test Remove the flow cell and connect the outlet tubing of the flow cell directly to the pump. Then flow an appropriate solvent (for example Isopropanol) at 10 ml/min. After several minutes check the cell visually. If it is necessary to check it for higher pressure, put an appropriate stainless steel tubing which can build up a back-pressure. C A UT I O N DO NOT apply higher back pressure to the flow cell than maximum pressure of the flow cell. Table 172 Pressure Rating on Flow Cells Type Standard Flow Cell Ultra High-Pressure Cell Pressure 40 bar 400 bar Preparative Flow Cell 40 bar Semi-Micro Flow Cell 40 bar Service Handbook for 1050 Series of HPLC Modules - 11/2001 657 VWD: Maintenance Information Using the Cuvette Holder Using the Cuvette Holder When required: If your own standard should be used to checkout the instrument. Tools required: None Parts required: Cuvette Holder 79853-60016 Cuvette with the “standard”, e.g. NIST certified holmium oxide sample This cuvette holder can be placed instead of a flow cell in the variable wavelength detector. Standard cuvettes with standards in it, for example, National Institute of Standards & Technology (NIST) holmium oxide solution standard, can be fixed in it. This can be used for wavelength verifications. Figure 239 Cuvette Holder 658 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Using the Cuvette Holder Preparation for this procedure are: 1 Locate the cuvette holder on the desk. ❏ Remove the normal flow cell. ❏ Install the cuvette holder in the instrument and perform a wavelength calibration. ❏ Have cuvette with standard available. 2 Unscrew the bracket. 3 Insert the cuvette with the sample into the holder. Light path Clear side Service Handbook for 1050 Series of HPLC Modules - 11/2001 659 VWD: Maintenance Information Using the Cuvette Holder 4 Replace the bracket and fix the cuvette. 5 Install the cuvette holder in the instrument. 6 Perform your verification. 660 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Replacing DCB Board and Firmware Replacing DCB Board and Firmware When performing one of these tasks, take care for electrostatic discharge protection to keep the electronics alive. DCB Board ❏ Note the parameters from 31:SET WL PARAM. ❏ Disconnect the power from the instrument. ❏ Remove main cover and disconnect all connectors from DCB. ❏ Replace DCB after loosening the 3 fixing screws. ❏ Fix all screws and reconnect all connectors to the DCB. ❏ Carefully remove the firmware ROM from removed DCB and insert it on new DCB. ❏ Replace main cover and turn the instrument ON. ❏ Turn lamp on and wait some minutes to stabilize the lamp. ❏ Perform functions 20:0th CALIB., 21:WL CALIBRATION, 44:DAC CALIB. and 45:COMPENSATE to input the detector specific parameters into the EEROM. DCB Firmware ❏ Disconnect the power from the instrument. ❏ Remove main cover. ❏ Carefully replace the firmware ROM. ❏ Replace main cover and turn the instrument ON. ❏ Turn lamp on and wait some minutes to stabilize the lamp. Service Handbook for 1050 Series of HPLC Modules - 11/2001 661 VWD: Maintenance Information Replacing Display Boards Replacing Display Boards ❏ Remove front panel assembly and disconnect cables between front panel and DCB. ❏ Unscrew the six screws which hold the plastic part at the metal frame (except the two screws that fix the leak assembly). ❏ Disconnect the grounding cable and the cable between the two display boards. ❏ Replace the defective board. ❏ To loosen the flat cable [3] from the keyboard, press a flat screwdriver onto the two noses on each side of the connector [1] to release the upper part [2] of the connector. Figure 240 Release of connector 662 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Replacing the Leak Interface Replacing the Leak Interface Leak Sensor Assembly ❏ Remove the flow cell. ❏ Remove top cover. ❏ Disconnect leak cable from DCB and the flat ribbon cable from DCB to keyboard at the KDI board. ❏ Unscrew the screws that fix the front panel. ❏ Remove front panel. ❏ Replace sensor board or complete assembly. Figure 241 Leak Sensor Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 663 VWD: Maintenance Information Replacing the Leak Interface Leak Interface ❏ Carefully remove the leak interface. ❏ Replace the defective item. All three parts (top, bottom and tubing are coming together as kit). ❏ Install the leak interface. Figure 242 Leak Interface 664 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Replacements in the Optical Unit Replacements in the Optical Unit The repair level of optical unit parts is component level. Refer to section “Optical Unit “C”” on page 688 for additional parts. N OT E The information in this chapter is based on the original optical unit (version “C”). In June 1995 this optical was replaced by the enhanced version “D” to overcome baseline stability problems in unstable environments. For details on this “D” version refer to section Enhanced Optical Unit Information “VWD: Enhanced Optical Unit Information” on page 705. WA R N I N G Be sure to wear a pair of safety or sun glasses. Since the deuterium lamp emits intensive ultraviolet light, it is dangerous to perform optical alignment without eye protection. Be careful not to expose your eyes directly to the light coming from the lamp. Service Handbook for 1050 Series of HPLC Modules - 11/2001 665 VWD: Maintenance Information Replacements in the Optical Unit Figure 243 Optical Unit Removing the Optical Unit ❏ Disconnect power from instrument. ❏ Remove flow cell. ❏ Remove top cover. ❏ Disconnect all cables that go from the optical to the Detector Controller Board (DCB). ❏ Place the instrument on its left or right side. ❏ Remove all nuts that fix the optical unit. ❏ Take out the optical unit. 666 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Replacements in the Optical Unit Replacing the PSC Board ❏ Refer to “Removing the Optical Unit” on page 666. ❏ Remove the PSC protection cover (2 screws). ❏ Loosen the PSC board (3 screws). ❏ Remove the lamp supply connector from the fan assembly. ❏ Fed the wire carefully between fan cover and power supply cabinet. If not possible, loosen the fan cover. ❏ Replace the PSC board and reuse the old cable to the DCB board. ❏ When replacing the PSC protection cover, take care for correct routing of the wire at the right side. Replacing Pre-amplifiers or Photodiodes ❏ Remove the top cover and the front panel assembly. ❏ Refer to Figure 244 for next steps. ❏ Remove the cover that protects the pre-amplifier. ❏ To replace the pre-amplifier boards ❏ disconnect cable from pre-amplifier board ❏ unscrew the board ❏ unsolder the wire from the photodiode ❏ replace the board. ❏ To replace the photodiode ❏ remove cover plate of photodiode ❏ unsolder photodiode ❏ unscrew photodiode ❏ replace photodiode. Service Handbook for 1050 Series of HPLC Modules - 11/2001 667 VWD: Maintenance Information Replacements in the Optical Unit Figure 244 Location of Photodiodes Sample Reference Replacing Grating Assembly Parts Photo Sensor ❏ Refer to “Removing the Optical Unit” on page 666. ❏ Remove the bottom plate of the optical unit. ❏ Unscrew the photo sensor and replace it. Grating For [ ] items refer to Figure 245 on page 669. ❏ Remove the top cover of the optical unit. ❏ Use a hex key (2.5 mm) to loosen the grating screw [2]. ❏ Replace the grating [1]. ❏ Refer to “Optical Alignment Procedures” on page 671. 668 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Replacements in the Optical Unit Grating Motor For [ ] items refer to Figure 245 on page 669. ❏ Refer to “Removing the Optical Unit” on page 666. ❏ Refer to “Replacing Grating Assembly Parts” on page 668 and take grating out. ❏ Remove the bottom plate of the optical unit. ❏ Remove the two springs. ❏ Unscrew the three screws [6] that fix the motor assembly [5] and take it out. Keep spring [3] and gasket [4]. ❏ Replace the spring [3], gasket [4] and complete motor assembly [5]. ❏ Reinstall the grating [1]. ❏ Refer to “Optical Alignment Procedures” on page 671. Figure 245 Grating Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 669 VWD: Maintenance Information Replacements in the Optical Unit Replacing Filter Assembly Parts ❏ Refer to Refer to “Removing the Optical Unit” on page 666. ❏ Remove the bottom plate of the optical unit. ❏ Unscrew the 2 screws that fix the filter assembly. ❏ Take out the complete assembly. ❏ Replace the complete filter assembly, sensor lever or the sensor. Figure 246 Filter Assembly Replacing Mirrors, Beamsplitter and Slits ❏ Open the optical untit's top cover. ❏ Replace the item that need to be replaced. ❏ Refer to “Optical Alignment Procedures” on page 671. N OT E DO NOT touch the surface of the mirrors, beam splitter and the grating. 670 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Optical Alignment Procedures Optical Alignment Procedures WA R N I N G Procedure 1: alignment after exchange of a specific part Procedure 2: alignment of complete optical (sample path) Procedure 3: alignment of complete optical (reference path) Be sure to wear a pair of safety or sun glasses. Since the deuterium lamp emits intensive ultraviolet light, it is dangerous to perform optical alignment without eye protection. Be careful not to expose your eyes directly to the light coming from the lamp. Procedure 1: Simple Alignment When replacing just a single part in the light path other than grating parts, M4 and beam splitter, this procedure can be performed. ❏ Execute 40:0th TEST which shows the step number from 31: SET WL PARM. and watch the location of the images on the slit assemblies (entrance and reference slit) and the cell center. ❏ Exchange the part Refer to Replacing ... for more information. ❏ Position the part so that the image centers on entrance and reference slit. ❏ Fix the part. ❏ If image on exit slit is too high or low, follow procedure “Procedure 2: Sample Beam Alignment” on page 672. ❏ If image on reference slit is too high or low, follow procedure “Procedure 3: Reference Beam Alignment” on page 674. ❏ Excute the 20:0th CALIB. and 21:WL CALIBRATION. ❏ Refer to “Replacement of Deuterium Lamp” on page 652, Step 2 and 3. Service Handbook for 1050 Series of HPLC Modules - 11/2001 671 VWD: Maintenance Information Optical Alignment Procedures Procedure 2: Sample Beam Alignment For [ ] items refer to Figure 247. M1, M2, Entrance Slit, ❏ Remove the entrance slit [3]. M3 ❏ Turn the deuterium lamp [1] on. ❏ Make sure the light spot covers over mirror M1 [4]. ❏ Adjust the direction of mirror M1 [4] so that the light beam covers over mirror M2 [5]. ❏ Adjust the angle and direction of mirror M2 [5] so that the light beam covers over mirror M3 [6]. ❏ Install the entrance slit [3] where the light beam illuminates the center of the slit. ❏ Adjust the angle and direction of the mirror M3 [6] so that the light beam covers over the grating mirror [7]. Figure 247 Optical Unit Parts 672 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Optical Alignment Procedures Grating, M4, Beam Splitter ❏ Excute control function 40:0TH TEST OFF to set the grating motor position to 200 steps (center step number). ❏ Adjust the direction of the grating mirror [7] so that the light beam covers over the mirror M4 [6]. ❏ Remove the beam splitter [8] now so that you can see the center of the flow cell. ❏ Adjust the angle and direction of the mirror M4 [6] so that the light beam illuminates the center of the flow cell. ❏ Leave control function 40:0TH TEST OFF and return to normal display. ❏ Excute the 20:0th CALIB. and 21:WL CALIBRATION. Refer to “Replacement of Deuterium Lamp” on page 652, Step 2 and 3. ❏ If grating has been moved, use 45:COMPENSATE to compensate non-linearity of the grating motor. ❏ Set wavelength to 254nm. ❏ Place cover on optical unit (do not fix the screws at this time). M4 fine tuning ❏ Excute control function 16:PHOTOCURRENT. ❏ Remove the blank screw for mirror M4 adjustment (Figure 243 on page 666) on the top cover (leave the blank screw for beam splitter adjustment in). ❏ Adjust the angle of the mirror M4 with inserting a hexagon wrench (1.5 mm) through the top cover screw hole to get maximum photocurrent for the sample. Turn right to move image down and left for up. ❏ Replace the blank screw in the top cover. ❏ Excute the 20:0th CALIB. and 21:WL CALIBRATION. Refer to “Replacement of Deuterium Lamp” on page 652, Step 2 and 3. ❏ Install the beam splitter [8]. Service Handbook for 1050 Series of HPLC Modules - 11/2001 673 VWD: Maintenance Information Optical Alignment Procedures Procedure 3: Reference Beam Alignment For [ ] items refer to Figure 247 on page 672. ❏ Excute 40:0TH TEST ON with calibrated step value displayed. ❏ Open the top cover and adjust the angle and direction of the beam splitter [8], so that the light beam illuminates the center of the reference slit [12]. ❏ Place the cover on the optical unit. ❏ Leave 40:0TH TEST ON and set wavelength to 254 nm.❏ Remove the blank screw for beam splitter adjustment (Figure 243 on page 666) in the top cover. ❏ Excute 16:PHOTOCURRENT. ❏ Adjust the angle of the beam splitter inserting a hexagon wrench through the top cover screw hole to get maximum photocurrent for the reference. Turn right to move image down and left for up. ❏ Replace the blank screw in the top cover. ❏ Repeat the 20:0TH CALIB. and 21:WL CALIBRATION. Refer to “Replacement of Deuterium Lamp” on page 652, Step 2 and 3. ❏ Use 45:COMPENSATE to compensate non-linearity of the grating motor. 674 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Cleaning of Optical Unit Parts Cleaning of Optical Unit Parts There are only a few parts within the optical unit that can be cleaned. Table 173 Cleanable Optical Parts NOT CLEANABLE grating and all mirrors Touching or cleaning will result in decrease of reflaction/intensity CLEANABLE filters (holmium, cutoff and 0 order calibration), beam splitter, photo diodes You can wipe the surface with ethanol. In case you cannot remove stains, the part has to be replaced. Service Handbook for 1050 Series of HPLC Modules - 11/2001 675 VWD: Maintenance Information Upgrade to GPIB Upgrade to GPIB ❏ Note the values for WL, 0 and 656 nm using 31:SET WL PARAM., just in case the EEROM looses the values. ❏ Turn off the instrument. ❏ Remove top cover of the instrument. ❏ Remove plate at the rear panel above the fan. ❏ Install the GPIB board in that location using the screws that hold the plate. ❏ Connect the GPIB cable to J12 of the DCB board. GPIB Address Setting The GPIB address setting is done with a switch (1) at the rear of the GPIB board. The factory setting is ’10’ (position A). Figure 248 Location of GPIB board 676 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Performance Verification Performance Verification Table 174 Noise and Drift Specifications Noise 1.5 x 10-5 AU Drift 5.0 x 10-4 AU/h What you need ❏ a pump that can deliver bidistilled water, at a rate of up to 1 ml/min against a back-pressure of about 200 bar. ❏ a column: we recommend our 100 x 4.6 mm i.d., 5 µm Hypersil ODS column. ❏ a recording device that can accept the output signal from your detector and that has attenuation set to about 35 cm/mV. Preparations ❏ Prime the pump and ensure there are no air bubbles in the system. ❏ Thoroughly degas about 300 ml of bidistilled water. ❏ Set pump to deliver bidstilled water at a flow rate of 1 ml/min. ❏ Set the attenuation to about 35 cm/mV. ❏ Set run time on recorder to 6.0 min. ❏ Turn-ON line power and deuterium lamp. ❏ Set wavelength to 254 nm, response time to 1 second and output voltage to 1 V. Service Handbook for 1050 Series of HPLC Modules - 11/2001 677 VWD: Maintenance Information Performance Verification Starting a run ❏ Give the optical unit time to warm-up and stabilize. ❏ Start a run. The baseline noise should not exceed 7.5 µV (1.5 x 10-5 AU|) equivalent to 4.5 mm at attenuation - 3 on a 3390/2/3 integrator and equivalent to 9 mm at attenuation - 3 on a 3394/6 integrator. Figure 249 Example of Noise Plot This plot was taken with • a 79853C VWD • an 35900C A/D converter • a LC DOS workstation • flow cell windows removed, but gasket #2 installed. It shows, that the drift on this example is < 1 x 10-4 AU/hr and the noise at about < 1 x 10-5 AU. 678 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Maintenance Information Performance Verification Scaling Factors The table below shows the scaling factors for the 339XA family of integrators. The 3390A, 3392A and 3393A have a full scale deflection of 75 mm. The 3394A and the 3396A have a full scale deflection of 150 mm, they also have an attenuation range between -8 and 36. Table 175 Scaling Factors on 339X integrators ATTN mV full scale mAU full scale -3 0.125 0.25 -2 0.25 0.5 -1 0.5 1 0 1 2 1 2 4 2 4 8 3 8 16 4 16 32 5 32 64 6 64 128 7 128 256 8 256 512 9 512 1024 10 1024 2048 Service Handbook for 1050 Series of HPLC Modules - 11/2001 679 VWD: Maintenance Information Performance Verification 680 Service Handbook for 1050 Series of HPLC Modules - 11/2001 30 30 VWD: Parts Information This chapter provides information on parts of the 1050 Variable Wavelength Detectors VWD: Parts Information This chapter gives diagrams for parts identification and the complete parts listings respectively. • Overall Diagram • Optical Unit • Flowcell • Flow Cell Kits • Accessory Kit N OT E The information in this chapter is based on the original optical unit (version “C”). In June 1995 this optical was replaced by the enhanced version “D” to overcome baseline stability problems in unstable environments. For details on this “D” version refer to section Enhanced Optical Unit Information “VWD: Enhanced Optical Unit Information” on page 705. 682 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Parts Information Overall Diagram Overall Diagram Table 176 Overall Diagram Item Description Part Nmber Item Description Part Nmber 1 Power Supply (5061-3375) 01050-69375 15 Cover Assembly 79853-64101 2 DCB Board Assembly, see * 79853-69511 16 GPIB Board Assembly 79853-68711 2 ROM DCB Firmware “C” only 79853-13005 16 ROM GPIB Firmware 79853-13004 2 ROM DCB Firmware “D” only 79853-13000 Cable DCB-GPIB 79853-61610 3 PSC Board for DCB 79853-66511 79853-66512 17 Fan Assembly (LOW) 79853-68503 4 Cable PSC-DCB 79853-61605 18 Cover Fan 79853-04102 5 Cover PSC N.A. 19 Sheet Fan N.A. 6 Leak Sensor Board see page 687 20 Fan Assembly (HIGH) 79853-68502 7 Leak Sensor Assembly see page 687 21 Switch Bearing 79853-61903 8 Sheet Front Panel see page 687 22 Switch Bracket N.A. 9 Front Panel Assembly see page 687 23 Switch Shaft 79853-61901 10 Display Interface (KDI) 79853-66502 24 Switch Top 79853-61902 11 Display Module (VFD) 79853-66503 25 Cable DCB-KDI 79853-61609 12 Cable KDI-VFD 79853-61602 26 Optical Unit see page 688 13 STD Flow Cell Assembly see page 693 13 Semi-micro Flow Cell Assembly see page 695 Transport Screw Kit, contains 3 screws with washer and spacer 79853-68700 13 Ultra High Pressure Flow Cell Assembly see page 697 PEEK Inlet Tubing Kit 5062-8522 13 Prep Flow Cell Assembly TI see page 698 PEEK Waste Tubing Kit 5062-8535 14 Bracket DPS N.A. * If installed in instruments with PSC -66509, then PSC must be updated to 79853-66512. Service Handbook for 1050 Series of HPLC Modules - 11/2001 683 VWD: Parts Information Overall Diagram Figure 250 Overall Diagram Part 1 684 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Parts Information Overall Diagram Figure 251 Overall Diagram Part 2 Service Handbook for 1050 Series of HPLC Modules - 11/2001 685 VWD: Parts Information Front Panel Parts Front Panel Parts Leak Interface Table 177 Leak Interface Description Part number Leak Interface Kit, contains 79853-68731 Top, Bottom and Tubing Figure 252 Leak Interface Top Tubing Bottom 686 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Parts Information Front Panel Parts Font Panel Table 178 Front Panel # Description Part number Front Panel Complete 79853-60203 Front Panel 79853-60202 1 Leak Sensor Board 79853-66510 2 Leak Sensor Assembly 79853-66111 3 Display Module Board (VFD) 79853-66503 4 Cable KDI-VFD 79853-61602 5 Display Interface (KDI) 79853-66502 6 Cable DCB-KDI 79853-61609 O-ring, Leak Assembly Figure 253 79853-82501 Front Panel Service Handbook for 1050 Series of HPLC Modules - 11/2001 687 VWD: Parts Information Optical Unit “C” Optical Unit “C” The parts identification of the optical unit is splitted into four sections: • Optical Unit Inner Parts (Top) • Optical Unit Inner Parts (Bottom) • Grating Assembly • Filter Assembly • Flow Cell Assemblies N OT E The information in this chapter is based on the original optical unit (version “C”). In June 1995 this optical was replaced by the enhanced version “D” to overcome baseline stability problems in unstable environments. For details on this “D” version refer to section Enhanced Optical Unit Information “VWD: Enhanced Optical Unit Information” on page 705. For complete optical unit “C” replacements use part number 79853-60015. This upgrades to “D” version, see “Part Numbers for Enhanced “D” Optical Unit” on page 709 688 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Parts Information Optical Unit “C” Optical Unit “C” Inner Parts Top Table 179 Optical Unit “C” Inner Parts TOP Item Description Part Nmber Item Description Part Nmber Optical Unit (complete assembly) 79853-69015 7 Grating Assembly see page 691 Plate Optical Top 79853-04108 8 Beam Splitter 79853-20402 79883-60002 9 Pre-Amplifier Board, SAMPLE 79853-66507 1 Deuterium Lamp Assembly Lamp housing 79853-22006 10 Sensor, Sample 79853-61109 2 Filter Assembly see page 692 11 Pre-Amplifier Board, REF 79853-66508 3 Entrance Slit Assembly 79853-23103 12 Sensor, Reference 79853-61110 4 Mirror #1 79853-68107 Reference Slit 79853-23104 5 Mirror #2 79853-68108 Spacer Reference Sensor 79853-24702 6 Mirror #3 or #4 79853-68109 PTFE Ring 53C 79853-24500 Figure 254 Optical Unit “C” Inner Parts TOP Service Handbook for 1050 Series of HPLC Modules - 11/2001 689 VWD: Parts Information Optical Unit “C” Optical Unit “C” Inner Parts Bottom Table 180 Optical Unit “C” Inner Parts Bottom Item Description Part Nmber Item Description Part Nmber Optical Unit (comple assembly) 79853-60015 7 Filter Assembly Plate Optical Base 79853-04109 7 Position Sensor Assembly, Filter 79853-61107 1 Optical Body N/A 8 Cable Assembly, Sample 79853-61607 2 Plate Sample Sensor 79853-04110 9 Cable Assembly, Reference 79853-61608 3 Position Sensor Assembly, Grating 79853-61106 Spacer, Optical (metal foot) 79853-24701 4 Plate Reference Sensor 79853-04111 Insulator, Optical (rubber foot) 79853-85401 5 Spring #1, Grating 79853-29102 Foot Kit Optical 79853-22005 6 Grating Assembly see page 691 Figure 255 see page 692 Optical Unit “C” Inner Parts Bottom 690 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Parts Information Grating Assembly Grating Assembly Table 181 Grating Assembly # Description Part number 1 Grating 79853-64605 Hex Screw M3 14 mm lg 2 Spring #2, Grating 3 Gasket 4 Grating Motor Assembly 5 Screws M3 6 mm long Photo Sensor Figure 256 79853-29103 79853-64606 79853-61106 Grating Assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 691 VWD: Parts Information Filter Assembly Filter Assembly Table 182 Filter Assembly # Description Part number 1 Filter Assembly 79853-67903 2 Lever Position Sensor 3 Position Sensor Filter 79853-61107 4 Screws M3 6 mm long Figure 257 Filter Assembly 692 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Parts Information Standard Flow Cell “C” (SST/Ti) Standard Flow Cell “C” (SST/Ti) Table 183 N OT E Standard Flow Cell “C” (SST/Ti) Item Description Part Nmber Qty 1 Cell Screw 79853-27201 2 Conical Spring 10/pk 79853-27203 10 3 Ring 2/pk 79853-27202 2 4 Gasket #1 PTFE 5 Window Quartz 6 Gasket #2 PTFE 7 Gasket #3 PTFE STD Flow Cell 8 mm SST see Note below STD Flow Cell 8 mm Ti 79853-60011 PEEK Inlet Tubing Kit 5062-8522 Cell Kit STD, includes items 4 (2x), 5 (2x), 6 (1x) and 7 (1x) 79853-68718 5 Window Quartz Kit 79853-68719 2 4 Gasket #1 PTFE Kit STD 10/pk 79853-68720 10 6 Gasket #2 PTFE Kit STD 5/pk 79853-68721 5 7 Gasket #3 PTFE Kit STD 5/pk 79853-68722 5 The original STD flow cell 79853-60008 was replaced in June 1995 by the “D” version 79853-60000. For parts ID refer to “Standard Flow Cell “D” Repair Parts” on page 710. Service Handbook for 1050 Series of HPLC Modules - 11/2001 693 VWD: Parts Information Standard Flow Cell “C” (SST/Ti) Figure 258 Standard Flow Cell “C” (SST/Ti) 694 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Parts Information Semi-Micro Flow Cell (SST) Semi-Micro Flow Cell (SST) Table 184 Semi-Micro Flow Cell (SST/Ti) Item Description Part Nmber Qty 1 Cell Screw (same as STD) 79853-27201 2 Conical Spring (same as STD) 79853-27203 10/pk 3 Ring (same as STD) 79853-27202 2/pk 4 Gasket #1 PTFE (same as STD) 10/pk 79853-68720 10/pk 5 Window Quartz (same as STD) 79853-68719 2/pk 6 Gasket #2 PTFE Micro 79853-68724 10/pk Semi-Micro Flow Cell (complete) 79853-60010 PEEK Capillary 400 mm lg ID 0.12 mm 5021-1823 Fitting for PEEK capillary 0100-1516 2/pk Cell Kit Micro, includes items 4 (2x), 5 (2x) and 79853-68723 6 (2x) Figure 259 Semi-Micro Flow Cell (SST) Service Handbook for 1050 Series of HPLC Modules - 11/2001 695 VWD: Parts Information High Pressure Flow Cell (SST) High Pressure Flow Cell (SST) Table 185 High Pressure Flow Cell (SST) Item Description 1 Cell Screw (same as STD) Part Nmber Qty 79853-27201 2 Ring POLYIMIDE 3 Window Quartz 79853-68740 2/pk 4 Gasket #1 POLYIMIDE 79853-68729 10/pk 5 Gasket #2 POLYIMIDE 79853-68730 5/pk High Pressure Flow Cell SST replaced by UHP Cell, see “Ultra High Pressure Flow Cell (SST)” on page 697 PEEK Tubing Assembly 5062-8522 Cell Kit HP, includes items 2 (2x), 3 (2x), 4 (2x) 79853-68728 and 5 (1x) N OT E The gaskets, windows and rings are not compatible with the Ultra High Pressure Cell (79853-600013) that replaced the high pressure flow cell (79853-60009). For parts identification refer to “Ultra High Pressure Flow Cell (SST)” on page 697. 696 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Parts Information Ultra High Pressure Flow Cell (SST) Ultra High Pressure Flow Cell (SST) Table 186 Ultra High Pressure Flow Cell (SST) Item Description 1 Cell Screw Part Nmber Qty 79853-27200 2 Ring PEEK UHP Figure 260 3 Window Quartz Kit, UHP 79853-68734 2/pk 4 Gasket #1 POLYIMIDE Kit UHP 79853-68737 2/pk 5 Gasket #2 POLYIMIDE Kit UHP 79853-68738 2/pk Ultra High Pressure Flow Cell SST 79853-60013 PEEK Tubing Assembly 5062-8522 Cell Kit UHP, includes items 2 (1x), 3 (2x), 4 (2x) and 5 (2x) 79853-68733 Ultra High Pressure Flow Cell (SST) Service Handbook for 1050 Series of HPLC Modules - 11/2001 697 VWD: Parts Information Preparative Flow Cell (Ti) Preparative Flow Cell (Ti) Table 187 Preparative Flow Cell (Titanium) Item Description Part Nmber 1 Cell Screw (same as STD) 79853-27201 2 Conical Spring (same as STD) 79853-27203 10/pk 3 Ring (same as STD) 79853-27202 2/pk 4 Gasket #1 PTFE (same as STD) 79853-68720 10/pk 5 Window #1 Quartz (same as STD) 79853-68719 2/pk 6 Gasket #2 PTFE (0.1) for 0.9 µl 6 Gasket #2 PTFE (0.2) for 1.8 µl 6 Gasket #2 PTFE (0.5) for 4.4 µl 6 Gasket #2 PTFE (1.0) for 8.8 µl 7 Window #2 Quartz 8 Gasket #3 PTFE Preparative Flow Cell (complete) 79853-60012 PEEK Tubing Assembly 5062-8522 Cell Kit PREP, includes items 4 (1x), 5 (1x), 6 (1 of each size), 7 (1x) and 8 (1x) 79853-68725 Qty Window Quartz Kit PREP includes items 5 (1x), 79853-68726 7 (1x) Gasket Kit PREP includes one of each size of gasket #2 698 79853-68727 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Parts Information Preparative Flow Cell (Ti) Figure 261 Preparative Flow Cell (Ti) Service Handbook for 1050 Series of HPLC Modules - 11/2001 699 VWD: Parts Information Cuvette Holder Cuvette Holder Table 188 Control Module Parts Item Description Part Number Cuvette Holder 79853-60016 For informationon the use of the cuvette holder, refer to “Using the Cuvette Holder” on page 658. Figure 262 Cuvette Holder 700 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Parts Information Accessories Accessories These parts are shipped with the 79853C VWD Table 189 Accessories Description Part number QTY Manual Getting Ready 01050-90211 1 Cable Remote 5061-3378 1 PEEK Waste Accessory Kit 5062-8535 1 Standard Accessory Kit 79853-68701 1 Fitting 0100-1516 1 Fuse 250 V 2A 2110-0002 3 Fuse 250 V 3A 2110-0003 3 Wrench 1/4-5/16 inch 8710-0510 1 Screwdriver POZI 1 PT 3 8710-0899 1 Leak Interface Kit 79853-68731 1 Manual SOP 79853-90009 1 includes Service Handbook for 1050 Series of HPLC Modules - 11/2001 701 VWD: Parts Information Screws Screws Below table lists all screws within the instrument. They can be bought locally, if needed. Table 190 Screws Location Size filter motor M 2.3 4 mm lg hexagon socket set screw with cup point grating motor M3 3 mm lg hexagon socket set screw with cup point mirror adjustment M3 8 mm lg hexagon socket set screw with dog point grating adjustment M3 14 mm lg hexagon socket cap screw grating motor M3 4 mm lg countersink screw to fix assemblies on the optical body; cover on M 3 the DCB board; plate of lamp house; KDI and VFD board; mirrors, filter and grating; 6 mm lg screw position sensor M3 6 mm lg screw with smaller head REF sensor plate M3 10 mm lg screw SAMP and REF amplifier boards M3 18 mm lg screw cover assembly; optical unit top cover; DCB and GPIB boards from rear panel; M4 6 mm lg screw with lock washer to fix assemblies on the base; DCB abd GPIB M 4 board; leak detector assembly; front panel bracket; SAMP and REF covers; optical unit bottom cover; blank screws of optical unit top cover; plate for cell on the optical body; 5 mm lg screw blank plate of cell; lock screws 12 mm lg screw 702 M4 Length Type Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Parts Information Screws Table 190 Screws Location Size Length Type lamp house M4 14 mm lg screw fan assemblies M4 35 mm lg screw cell M5 10 mm lg screw All screws are plus-shaped type. Service Handbook for 1050 Series of HPLC Modules - 11/2001 703 VWD: Parts Information Screws 704 Service Handbook for 1050 Series of HPLC Modules - 11/2001 31 31 VWD: Enhanced Optical Unit Information This chapter provides information about the enhanced optical unit “D” VWD: Enhanced Optical Unit Information Since June 1995, the design of the optical unit for the 79853C Variable Wavelength Detector (VWD) was changed to improve its performance under unstable temperature conditions. Together with the enhanced optical unit (“D”), the standard flow cell was changed (79853-60000). N OT E In this document the term “D” is used for the new enhanced optical design and “C” for the original optical design. Compatibility This new enhanced optical unit (“D”) is fully backward compatible with all 79853C VWDs shipped since January 1992. The new standard flow cell (79853-60000) is backward compatible with the “C” optical unit. Some of the parts for the enhanced optical unit (“D”) are not usable in the “C” version. In case of replacing a “C” optical unit with an enhanced “D” optical unit, the new standard flow cell is required. Support of Previous Optical Units The parts for the “C” optical unit will continue to be available as a repair part as long as the 79853C is supported (08/2006). In case the complete “C” optical must be replaced, use the “D” upgrade mentioned on “Part Numbers for Enhanced “D” Optical Unit” on page 709. 706 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Enhanced Optical Unit Information Introduction Introduction To overcome wander problems due to temperature variations of the lab environment, the optical unit of the 79853C Variable Wavelength Detector (VWD) has been modified. Following hardware modifications were implemented in June 1995: • different coupling of the lamp housing (lens between lamp housing and optical casting). • area around mirror M1 and M2 has been redesigned to eliminate one mirror - result is a mirror #1 assembly with a plane mirror. • redesigned entrance slit holder. Slits are changeable (standard/test). • beam splitter assembly no longer vertically adjustable. • reference slit assembly redesigned for better optimization. • new standard flow cell with different aperture material and different inlet capillary. Figure 263 Optical Path of Enhanced Optical Unit new lens assembly new entrance slit assembly new mirror #1 assembly new beam splitter assembly new reference slit new standard flow cell Service Handbook for 1050 Series of HPLC Modules - 11/2001 707 VWD: Enhanced Optical Unit Information Support Considerations Support Considerations Prefix Change The enhanced Optical Unit (“D” version) was introduced in production units in June 1995. Since the detector appears to look the same as before, a prefix change was made. All units with prefix 3522 J 04305 and above have the new optical installed. N OT E Some units with a prefix lower than 3522 J 04305 have been installed on customer sites prior to the official shipments. Identification Following identifications for the enhanced “D” version are available: • Prefix and serial number 3522 J 04305 and above (rear of instrument) • firmware revision 4.31 (press CTRL 12 ENTER ENTER DOWN) • label on the optical unit “ENHANCED ILLUMINATION SYSTEM” • handle of new reference slit looking out of the optical’s cover plate (see Figure 266 on page 715). Compatibility Matrix Due to a redesign, several components are usable in the enhanced “D” version only. Refer to Table 191 on page 709 for details. N OT E Both optical unit versions (“C” and “D”) can be operated with firmware revision 4.24 (79853-13005). Due to the modifications, the photocurrent readings are about 50% of those of the original “C” opticals. To make them comparable the firmware for the enhanced “D” version got a new revision and part number. 708 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Enhanced Optical Unit Information Part Numbers for Enhanced “D” Optical Unit Part Numbers for Enhanced “D” Optical Unit Table 191 Enhanced “D” Version Part Numbers Part Number Description Comments 79853-60000 Standard Flow Cell backward compatible*, for details see Table 192 on page 710. 79853-69014 Exchange “D” Optical includes firmware 79853-13000 when “D” optical should be replaced, needs Standard Flow Cell 79853-60000 79853-69015 Exchange “D” Optical includes a Standard Flow Cell 79853-60000 and firmware 79853-13000 when “C” optical should be replaced 79853-68110 “D” Mirror 1 Assembly for “D” only, includes test slit 79853-68111 “D” Mirror 3/4 Assembly backward compatible**, includes test slit 79853-68112 “D” Beam Splitter for “D” only, includes test slit 79853-68113 “D” Lens Assembly for “D” only, includes test slit 79853-66508 Pre-amplifier Board REF from “C” used for SAMPLE and REFERENCE on “D” 79853-61109 Diode Sample from “C” used for SAMPLE and REFERENCE on “D” 79853-64605 Grating Assembly same part number as before, but test slit added 79853-13000 Firmware “D” rev 4.31 for “D” only, added also to 79853-69014/15 and 79853-69511 (DCB) 79853-68746 Slit Kit “D” Test slit plus STD slit * ** with “C” version optical units with “C” version optical units; part number 79853-68109 should only be used for 79853C optical until stock has expired. N OT E The part numbers 79853-68110, -68111, -68112, -68113 and -64605 include beside the test slit in addition a seal to close the hole for Mirror 4 adjustment setscrew. Close the hole with this seal during replacements (see Figure 266 on page 715 for the location). Service Handbook for 1050 Series of HPLC Modules - 11/2001 709 VWD: Enhanced Optical Unit Information Standard Flow Cell “D” Repair Parts Standard Flow Cell “D” Repair Parts Table 192 Standard Flow Cell “D” Repair Parts Item 1 Description Part Number STD Flow Cell “D”, complete assembly 79853-60000 Cell Screw 79853-27200 Kits: Cell Kit STD “D”, consists of: two windows, two gaskets #1, 79853-68741 one gasket #2 and one gasket #3. Figure 264 2 Conical Spring “D”, Qty=10 79853-29100 3 Ring SST “D”, Qty=2 79853-22500 5 Window Quartz “D”, Qty=2 79853-68742 4 Gasket #1 “D”, PTFE, Qty=10 79853-68743 6 Gasket #2 “D”, Aperture, gold, Qty=5 79853-68744 7 Gasket #3 “D”, PTFE, Qty=5 79853-68745 Standard Flow Cell “D” Repair Parts 1 2 3 4 5 6 7 5 4 3 2 1 710 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Enhanced Optical Unit Information Repair and Mainenance Repair and Mainenance WA R N I N G These procedures need special knowledge on servicing the 79853C VWD and should be done by trained Service Engineers only. These procedures should be carried out in a room where the light can be reduced. Since the deuterium lamp emits intensive ultraviolet light, it is dangerous to perform optical alignment without eye protection. Tools required: ❏ Test Slit (supplied with mirror or grating assembly) ❏ Pozi Driv PT1 ❏ hexagonal wrench (1.5 mm) ❏ hexagonal wrench (2.5 mm) ❏ pair of tweezers (not too sharp points) Pre-requisites: ❏ Assure that the flow cell is clean, flushed with water and bubble free. ❏ Remove detector from system. ❏ Place the detector on a bench. ❏ Remove the main cover. Service Handbook for 1050 Series of HPLC Modules - 11/2001 711 VWD: Enhanced Optical Unit Information Additional Information Additional Information For additional information about replacements and the use of the Service control Functions refer to “VWD: Maintenance Information” on page 649 and “Service Control Functions” on page 622. Replacements and Calibrations The following procedures describe the replacements of parts separately. N OT E It is important that only one assembly (mirror, grating, beam splitter, ...) is changed and calibrated at a time. Otherwise you will lose correct optical assembly alignment during the calibration process. WA R N I N G Do not remove the Entrance Slit Holder nor loosen it. Otherwise the optical unit has to be exchanged completely. N OT E The photocurrent readings with test slit installed are much lower than with the standard slit. 712 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Enhanced Optical Unit Information Installing the Test Slit Installing the Test Slit The small diameter of the test slit allows a straight forward alignment of the optical path. It enables the lamp image to be positioned optimally. This ensures correct illumination of the Entrance Slit and the Reference Slit. N OT E This procedure has to be carried out at the beginning of all replacement procedures. 1 Turn on the detector and the lamp. 2 Set the wavelength to 250 nm. 3 Carefully remove the cover of the optical unit. Take care for the reference aperture handle, see Figure 266 on page 715. 4 Remove the standard slit from the entrance slit holder using a pair of tweezers and place it safe. Figure 265 Replacing the Entrance Slit entrance slit assembly entrance slit mirror #1 assembly test slit Service Handbook for 1050 Series of HPLC Modules - 11/2001 713 VWD: Enhanced Optical Unit Information Installing the Test Slit 5 Carefully insert the test slit (with round hole) into the entrance slit holder. The slit must sit flat on the holder with the white side towards the incoming light. 714 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Enhanced Optical Unit Information Replacing Mirror #1 Assembly Replacing Mirror #1 Assembly 1 Install the Test Slit, see “Installing the Test Slit” on page 713. 2 Remove mirror #1 assembly. 3 Install new Mirror #1 assembly. N OT E DO NOT remove or change its position of adapter plate underneath the mirror #1 assembly. 4 Position the lamp image onto the test slit hole: - horizontally by rotating the mirror, - vertically using the setscrew on the mirror. 5 Fix the mirror. 6 Install the Standard Slit and perform grating calibrations, see “Installing the Standard Slit” on page 726. 7 Carefully replace the cover of the optical unit. Take care for the reference aperture handle. 8 Reassemble the detector. Figure 266 handle of reference aperture Handle of the Reference Aperture hole / seal of Mirror #4 for alignment cover of optical unit Service Handbook for 1050 Series of HPLC Modules - 11/2001 715 VWD: Enhanced Optical Unit Information Replacing Mirror #3 or #4 Assembly Replacing Mirror #3 or #4 Assembly N OT E Replace and calibrate one mirror at a time. 1 Install the test slit, see “Installing the Test Slit” on page 713. 2 Carefully replace the cover of the optical unit. Take care for the reference aperture handle, see Figure 266 on page 715. 3 Execute CTRL 20: 0th CALIB. 4 Activate service function CTRL 40: 0TH TEST ON. 5 Carefully remove the cover of the optical unit. Take care for the reference aperture handle, see Figure 266 on page 715. 6 Unlock the reference aperture, “Unlocking the Reference Aperture” on page 723. 7 Center the reference slit on the white image by moving the aperture up or down, see Figure 267. The image diameter is nearly equal to the reference slit diameter. Figure 267 Algning the Reference Slit handle of reference aperture reference image 716 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Enhanced Optical Unit Information Replacing Mirror #3 or #4 Assembly 8 Install new mirror #3 or #4 assembly. 9 Position the white image precisely onto the reference slit: - horizontally by rotating the mirror, - vertically using the setscrew of the mirror 10 Carefully replace the cover of the optical unit. Take care for the reference aperture handle. 11 De-activate CTRL 40: 0TH TEST OFF, press CLEAR, CLEAR and BALANCE. 12 Set λ=250 nm. 13 Activate CTRL 16: PHOTOCURRENT. 14 Optimize the sample readings using the setscrew of mirror #4 through the hole in the optical unit cover, see Figure 266 on page 715. 15 Optimize the reference readings with the reference aperture, see “Optimizing the Reference Readings” on page 725. 16 Install the standard slit and perform electronic calibrations, see “Installing the Standard Slit” on page 726. Service Handbook for 1050 Series of HPLC Modules - 11/2001 717 VWD: Enhanced Optical Unit Information Replacing the Grating or Grating Motor Replacing the Grating or Grating Motor N OT E To replace the Grating and/or the Grating Motor refer to “Replacing Grating Assembly Parts” on page 668 and continue with the Alignment Procedure below. 1 Install the test slit, see “Installing the Test Slit” on page 713. 2 Carefully replace the cover of the optical unit. Take care for the reference aperture handle, see Figure 266 on page 715. 3 Execute CTRL 20: 0th CALIB. 4 Activate service function CTRL 40: 0TH TEST ON. 5 Carefully remove the cover of the optical unit. Take care for the reference aperture handle, see Figure 266 on page 715. 6 Unlock the reference aperture, see “Unlocking the Reference Aperture” on page 723. 7 De-activate CTRL 40: 0TH TEST OFF. 8 Center the reference slit on the white image by moving the aperture up or down. The image diameter is nearly equal to the reference slit diameter. 9 Remove the grating and reassemble new grating. N OT E Assure that the grating is not fixed on the shaft with the setscrew. 10 Set the Param. λ=200, using service function CTRL 31: SET λ PARAM. 11 Activate service function CTRL 40: 0TH TEST ON. 12 Turn the grating so that the center of the image is on the reference slit (a small horizontal and vertical deviation can be accepted). 13 Fix the grating with the setscrew. 14 De-activate and re-activate CTRL 40: 0TH TEST and check the position of the image on the reference slit. If not correct, loosen the grating and repeat steps 12 to 14. 718 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Enhanced Optical Unit Information Replacing the Grating or Grating Motor 15 Do a vertical adjustment with Mirror #4 for precise vertical fit of image on reference slit, using the setscrew of mirror #4 through the hole in the optical unit cover, see Figure 266 on page 715. 16 Carefully replace the cover of the optical unit. Take care for the reference aperture handle. 17 De-activate CTRL 40: 0TH TEST OFF, press [CLEAR], [CLEAR] and [BALANCE]. 18 Execute CTRL 20: 0th CALIB. 19 Activate CTRL 40: 0TH TEST ON and readjust the Beam Splitter for ideal horizontal fit. 20 De-activate CTRL 40: 0TH TEST OFF. 21 Set λ=250 nm. 22 Activate CTRL 16: PHOTOCURRENT. 23 Optimize the sample readings, using the setscrew of mirror #4 through the hole in the optical unit cover, see Figure 266 on page 715. 24 Unlock the reference aperture, see “Unlocking the Reference Aperture” on page 723. 25 Optimize the reference readings with the reference slit, see “Optimizing the Reference Readings” on page 725. 26 Install the standard slit and perform electronic calibrations, see “Installing the Standard Slit” on page 726. Service Handbook for 1050 Series of HPLC Modules - 11/2001 719 VWD: Enhanced Optical Unit Information Replacing the Beam Splitter Replacing the Beam Splitter 1 Install the test slit, see “Installing the Test Slit” on page 713. 2 Execute CTRL 20: 0th CALIB. 3 Carefully remove the cover of the optical unit. Take care for the reference aperture handle, see Figure 266 on page 715. 4 Activate service function CTRL 40: 0TH TEST ON. 5 Unlock the reference aperture, see “Unlocking the Reference Aperture” on page 723. 6 Center the reference slit on the white image by moving the aperture up or down. The image diameter is nearly equal to the reference slit diameter. 7 Install the new beam splitter assembly. 8 Position horizontally the white image center of the beam splitter onto the reference slit. 9 Fix the beam splitter after precise image fit. 10 Correct new vertical position with reference slit. 11 Carefully replace the cover of the optical unit. Take care for the reference aperture handle. 12 De-activate CTRL 40: 0TH TEST OFF, press [CLEAR], [CLEAR] and [BALANCE]. 13 Set λ=250 nm. 14 Activate CTRL 16: PHOTOCURRENT. 15 Optimize the sample readings using the setscrew of mirror #4, using the setscrew of mirror #4 through the hole in the optical unit cover, see Figure 266 on page 715. 16 Optimize the reference readings, see “Optimizing the Reference Readings” on page 725. 17 Install the standard slit and perform electronic calibrations, see “Installing the Standard Slit” on page 726. 720 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Enhanced Optical Unit Information Cleaning or Replacing the Lens Cleaning or Replacing the Lens The lens is located between lamp housing and casting and can be cleaned or replaced. 1 Turn the detector off. 2 Disconnect the lamp connector and all other connectors to the DCB board. 3 Remove the optical unit completely from the instrument. 4 Unscrew the four screws of the lamp housing and remove lamp housing. Figure 268 Lens Assembly Location lens assembly spring washer location of lens assembly casting of optical unit lamp housing with lamp N OT E For easier repositioning the lens ring is marked with color paint, see Figure 269 on page 722. The position of the marker could differ from instrument to instrument and may be different to the position shown in the figure. 5 Remove, clean or replace the lens. If reusing old lens use markings for repositioning. Service Handbook for 1050 Series of HPLC Modules - 11/2001 721 VWD: Enhanced Optical Unit Information Cleaning or Replacing the Lens Figure 269 Lens Position marker lens assembly N OT E The more plane lens side with smaller aperture faces towards the lamp. N OT E If a new lens is installed, mirror #1 assembly has to be realigned after this procedure, see “Replacing Mirror #1 Assembly” on page 715. 6 Reassemble the flat spring. 7 Replace the Lamp housing and tighten it. 8 Reassemble the detector. 722 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Enhanced Optical Unit Information Unlocking the Reference Aperture Unlocking the Reference Aperture N OT E Only necessary, if required during a replacement procedure. For performance reasons, the reference aperture is fixed by one screw only and has to be unlocked prior to any replacement/calibration within the optical unit. 1 Unscrew the front panel and place it in front of the detector to have access to the reference pre-amplifier area. N OT E When moving the front panel, assure that the keyboard cable is not partially disconnected - damage to the electronics is possible. 2 Unscrew the right screw of the reference pre-amplifier cover and loosen the left screw. 3 Turn the cover counter-clockwise until you can loosen the top screw of the photo diode holder sheet. Figure 270 Unlocking the Reference Slit handle of reference aperture lock screw reference diode assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 723 VWD: Enhanced Optical Unit Information Unlocking the Reference Aperture 4 Replace the reference pre-amplifier cover (to prevent stray light). 5 Fit the front panel with one screw at the right of the mainframe. 6 Turn on the detector and the lamp 7 Set wavelength to 250 nm. 8 Return to your replacement procedure. 724 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Enhanced Optical Unit Information Optimizing the Reference Readings Optimizing the Reference Readings 1 Carefully replace the cover of the optical unit. Take care for the reference aperture handle. 2 Activate CTRL 16: PHOTOCURRENT. 3 Shift reference aperture vertically for maximum reference readings. 4 Fix the reference slit with the top lock screw of the photo diode assembly. 5 Replace the reference photodiode cover. 6 Continue with the next step of the procedure of the assembly you are replacing. Figure 271 Optimizing the Reference Readings handle of reference aperture lock screw reference diode assembly Service Handbook for 1050 Series of HPLC Modules - 11/2001 725 VWD: Enhanced Optical Unit Information Installing the Standard Slit Installing the Standard Slit N OT E This procedure has to be carried out at the end of all replacement procedures. 1 Carefully remove the cover of the optical unit. Take care for the reference aperture handle, see Figure 266 on page 715. 2 Remove the test slit from the entrance slit holder using a pair of tweezers and place it safe. Figure 272 Replacing the Entrance Slit entrance slit assembly test slit mirror #1 assembly standard slit 3 Carefully insert the standard slit into the entrance slit holder. The slit must sit plane on the holder. 4 Carefully replace the cover of the optical unit. Take care for the reference aperture handle, see Figure 266 on page 715. 5 Execute CTRL 20: 0th CALIB. 6 Execute CTRL 21: l CALIBRATION. 7 Reassemble the detector. 726 Service Handbook for 1050 Series of HPLC Modules - 11/2001 32 32 VWD: Additional Information This chapter provides additional information about the 1050 Variable Wavelength Detectors VWD: Additional Information Since the introduction of the 79853C Variable Wavelength Detector in 1991, the following hardware and firmware changes have been implemented. 728 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Additional Information Product History Product History Since introduction of the 79853C Variable Wavelength Detector in January 1992 following changes have been implemented. Prefix Changes Table 193 Prefix Changes Serial Number Changes Additional Information 3145 J 00101 Start of customer shipments ∅ 3152 J 00263 New amplification factor of reference See “Modified side due to high output of new DAD Pre-Amplifier Gain” on lamps. page 734. 3152 J 00489 Introduction of DCB firmware revision See “SN 01050-055” on 4.22 page 734. 3217 J 00603 Introduction of DCB firmware revision See “SN 01050-055” on 4.23 page 734. 3225 J 00773 Introduction of DCB firmware revision See “SN 01050-055” on 4.24 page 734. 3225 J 01801 Introduction of PTFE ring in optical unit See “SN 01050-068” on page 734. Volume changes on Preparative Flow See Table 138 on page Cell in September 1992 574 and Table 187 on page 698. 3225 J 02011 Introduction of new DCB/PSC boards See “SN 01050-072” on page 734. 3323 J 03117 Introduction of new lamp housing 3334 J 03255 Change of manufacturing process for to improve stability photo diodes mounting against humidity Ultra High Pressure cell replaced High Pressure Cell in 1993 Service Handbook for 1050 Series of HPLC Modules - 11/2001 729 VWD: Additional Information Product History Table 193 Prefix Changes Serial Number Changes Additional Information 3522 J 04305 Enhanced optical unit “D” with STD flow cell “D” in June 1995 to improve temperature stability, see “VWD: Enhanced Optical Unit Information” on page 705 730 Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Additional Information DCB ROM Firmware Revisions DCB ROM Firmware Revisions Table 194 DCB ROM Firmware Revisions Revision Major Changes Comments 4.08 Used for first internal Waldbronn/Avondale units and some demo units. 4.09 PHOENIX problem: won’t stop when running with A/D Concerter (for example ABORT). Not released.Used for internal Waldbronn/Avondale tests. 4.21 CTRL 45 COMPENSATE bug fix, calibrated wavelength deviation might exceed the specification. CTRL 22 HOLMIUMCHECK for GLP reasons added. Released for 79853C in January 1992. For replacements use part number 79853-13005 (4.24). NEEDS GPIB ROM version 0.20 or above (79853-13004) 4.22 New algorithm for CTRL 45 COMPENSATE and CTRL 22 HOLMIUMCHECK. Released for 79853C in March 1992. Started with serial number 3152J00489. For replacements use part number 79853-13005 (4.24). NEEDS GPIB ROM version 0.20 or above (79853-13004) 4.23 Removed bug: Incorrect wavelength setting during stepper motor intialisation bewteen 536.4 nm and 600 nm. Released for 79853C in April 1992. Started with serial number 3217J00603. For replacements use part number 79853-13005 (4.24). NEEDS GPIB ROM version 0.20 or above (79853-13004) Service Handbook for 1050 Series of HPLC Modules - 11/2001 731 VWD: Additional Information DCB ROM Firmware Revisions Table 194 DCB ROM Firmware Revisions Revision Major Changes Comments 4.24 Removed bug : EEROM DATA LOST1 Released for 79853C in June 1992. Removed bug : Wavelength accuracy Started with serial number between 360 nm and 486 nm 3225J00773. For replacements use part number 79853-13005 (4.24). NEEDS GPIB ROM version 0.20 or above (79853-13004) 4.31 For Enhanced Optical Unit “D” only 732 Released for 79853C in June 1995. Started with serial number 3522J04305. For replacements use part number 79853-13000 (4.31). NEEDS GPIB ROM version 0.20 or above (79853-13004) Service Handbook for 1050 Series of HPLC Modules - 11/2001 VWD: Additional Information GPIB ROM Firmware Revisions GPIB ROM Firmware Revisions The table below lists all GPIB ROM firmware revisions for the 79853A/C. Table 195 GPIB ROM Revisions Revision Major Changes Comments 0.04 First official realease for 79853A. 0.05 LC APPACK problem: BUFFER OVERFLOW message preventing run buffer overflow. Released for 79853A. 0.08 Also useable for 79853C. PHOENIX Released for 79853A and 79853C. problem: prevents hang-ups at power For replacements use part number on (if VWD is switched on after 79853-13004 (0.2X) PHOENIX has been switched on). 0.09 PHOENIX problem: prevents VECTRA 486 hang-ups. NOT officially released. 0.20 additional changes for future PHOENIX enhancements. Released for 79853A and 79853C in January 1992. Required for 79853C firmware revision 4.21 and above. For replacements use part number 79853-13004 (0.2X) Service Handbook for 1050 Series of HPLC Modules - 11/2001 733 VWD: Additional Information Hardware Changes and Service Notes Hardware Changes and Service Notes Modified Pre-Amplifier Gain First instruments where shipped with a pre-amplifier gain of 100% on the reference side. The new deuterium lamps (79883-60002) showed sometimes very high energies which gave very high numbers on the reference side 16:PHOTOCURRENT. To prevent an overload the amplification factor was changed to 75%. The feedback resistors on the reference side changed from 200 MOhm to 150 MOhm and on the sample side from 100 MOhm to 75 MOhm. N OT E No revision change was made. The modified pre-amplifiers started with serial number 3145J00263. Important Service Note SN 01050-055 Service Note 1050-055 describes the introduction of the DCB firmware revision 4.24 and the problems with previous revisions in more detail. SN 01050-068 This note describes problems with POM ring between lamp housing and optical casting. Exchange POM ring against PTFE Ring 53C (79853-24500). SN 01050-072 This note describes problems with negative baseline jumps on analog output signal. New DCB (79853-66511) and PSC (79853-66512) Boards have been introduced. SN 01050-085 This note describes the optimization for drift problems. SN 01050-104 Introduction of Enhanced Optical Unit, see “VWD: Enhanced Optical Unit Information” on page 705. SN 01050-107 Cuvette Holder for Wavelength Verification with Certified Standard Solutions available see “Cuvette Holder” on page 700. SN 01050-112 Check of photometric accuracy - information on path lengths of flow cells, see “Correction factors for 79853C flow cells” on page 575. 734 Service Handbook for 1050 Series of HPLC Modules - 11/2001 In This Book This manual contains technical information about the Agilent 1050 liquid chromatographs. This manual is available as electronic version (Adobe Acrobat Reader file) only.