Fire Alarm Panel Upgrade PROJECT LOCATION: Queen`s Park
Transcription
Fire Alarm Panel Upgrade PROJECT LOCATION: Queen`s Park
CITY OF NEW WESTMINSTER Fire Alarm Panel Upgrade, Queen’s Park Arena NWIT-10-40 TENDER DOCUMENTS COVERING PAGE PROJECT TITLE: Fire Alarm Panel Upgrade PROJECT LOCATION: Queen’s Park Arena 51 Third Avenue Queen’s Park New Westminster, BC BID DUE: 3:00 PM (Local Time) on Wednesday, September 1, 2010 MANDATORY BIDDERS MEETING: DATE: 10:00 am (Local Time) on Wednesday, August 18, 2010 Queen’s Park Arena Queen’s Park See Queen’s Park Map for location New Westminster, BC August 12, 2010 CITY OF NEW WESTMINSTER 511 Royal Avenue New Westminster, B.C. V3L 1H9 Document #140829 CITY OF NEW WESTMINSTER Fire Alarm Panel Upgrade, Queen’s Park Arena NWIT-10-40 TENDER DOCUMENTS COVERING PAGE BID DOCUMENTS: Pages 1. 2. 3. 4. 6. 7. 1–2 1–4 1–4 1–5 1–1 Covering Pages Instructions to Bidders Bid Form General Requirements Supplementary Conditions to CCDC 2-2008 Drawings & Specifications listed below Title Dwg. No. Pages Key Plan and Specifications E100 1 Page Main Level Floor Plan E101 1 Page Upper Level Floor Plan E102 1 Page Specifications E103 1 Page Queen’s Park Map Document #140829 1 Page CITY OF NEW WESTMINSTER Fire Alarm Panel Upgrade, Queen’s Park Arena INSTRUCTIONS TO BIDDERS Page 1 of 4 1.0 Scope Of Work 1.1 Provide all labour, materials, plant, and equipment necessary to replace the existing fire alarm system with new, utilizing existing wiring and conduit infrastructure, as specified in the Tender Documents, General Requirements, Specifications, and Drawings. 2.0 Owner 2.1 The owner is the City of New Westminster, 511 Royal Avenue, New Westminster, B.C., V3L 1H9, herein after referred to as the “City”. 3.0 Submission Of Tender 3.1 Bidders shall submit the Tender on the enclosed Bid Form in a sealed envelope, clearly marked NWIT-10-40 Fire Alarm Panel Upgrade, Queen’s Park Arena. 3.2 The completed Tender shall be submitted to: Information Desk City of New Westminster 511 Royal Avenue New Westminster, B.C. V3L 1H9 Attention: Purchasing Manager 3.3 The City shall receive Tenders at the location specified in 3.2 above, prior to 3:00 PM (Local Time) on Wednesday, September 1, 2010. 3.4 Bidders shall submit the Bid Form with all blank spaces filled in. Alterations, qualifications, or omissions to the Bid Form may render the Bid liable for rejection by the City. The Bidder shall initial any erasures or corrections to the entries on the Bid Form. 3.5 The City does not accept facsimile, electronic mail, or other unsealed Bids. 3.6 The official time will be that on the clock located at the Information Desk. The City will not accept late submissions. 3.7 The City will not open this Tender in public. 4.0 Addenda 4.1 Should addenda to the Bid Documents be required for any reason, it is the City’s intention not to issue addenda during a period three (3) days prior to the Bid Closing date and time. 4.2 All Addenda become part of the Contract Documents. Bidders should include adjustment costs in the Bid Price. 4.3 Failure to acknowledge any Addendum may result in the disqualification of the Bidder. Document #140829 CITY OF NEW WESTMINSTER Fire Alarm Panel Upgrade, Queen’s Park Arena INSTRUCTIONS TO BIDDERS Page 2 of 4 5.0 Acceptance Of Bid 5.1 The City is not obligated to accept the lowest or any tender and may reject all bids. 5.2 The City may waive any non-compliance with the Bid Documents. 5.3 The City may, prior to contract award, negotiate changes to the scope of work with the low bidder or any one or more bidders without having any duty or obligation to advise any other bidders or to allow them to vary their bid prices due to changes to the scope of work. 5.4 Bids shall remain open for acceptance by the City for a period of sixty (60) days from the closing date. 6.0 Revision Of Bid 6.1 A Bid Form already delivered to the City may only be revised in the manner described below and, to qualify, the revision must be actually received by the City at the address given herein prior to the time and date specified for the closing of this Tender. 6.2 Bidders shall submit written Bid Revisions only in a sealed envelope. The Bidder may revise only the Bidder’s entries on the delivered Bid Form. 6.3 The City will not accept revisions of Bids by facsimile or email. 7.0 Knowledge Of Site And Work 7.1 Bidders shall visit the site of the work and make allowances in their bids for such conditions as in the sole opinion of the bidder are warranted. The City makes no representation or warranty as to the conditions of the site. 8.0 Proof Of Insurance 8.1 Within seven (7) days of acceptance of the Bid by the City and prior to the work starting, the Contractor shall provide proof of the insurance required by the Contract by delivering a completed certificate of insurance to the City. 9.0 Permits 9.1 If requested, the Contractor shall apply and pay for all permits required, by authorities having jurisdiction, to carry out the work. The City will apply for and pay for the building permit. 9.2 The successful Bidder is required to obtain a City of New Westminster Business license prior to commencement of work. Document #140829 CITY OF NEW WESTMINSTER Fire Alarm Panel Upgrade, Queen’s Park Arena INSTRUCTIONS TO BIDDERS Page 3 of 4 10.0 Pricing Requirements 10.1 All prices shall be firm and shall include the cost of labour, materials, equipment, permits, transportation, services, fuel charges, and all Federal and Provincial taxes in force as of the date of submission of the offer, except that the HST (Harmonized Sales Tax) shall be excluded from the price. 11.0 Queries 11.1 The City requests Bidders to advise the City of any errors, conflicts, or omissions in the Bid Documents so the City may issue an addendum. 11.2 After the Bid is accepted, bidders shall abide by the City's decision in the correction of previously unidentified obvious errors, conflicts, or omissions. 11.3 Address all queries or requests for additional information to: Heather Rossi, Purchasing Department, City of New Westminster, E-mail: hrossi@newwestcity.ca 12.0 Mandatory Bidders’ Meeting 12.1 The City has arranged a Mandatory Bidders’ Meeting on Wednesday, August 18, 2010 at 10:00 am at Queen’s Park Arena, Queen’s Park, New Westminster. See enclosed Queen’s Park Map for location. 12.2 To be eligible to submit a Bid for this Tender, Bidders must attend the Mandatory Bidders’ Meeting. Failure to attend the Mandatory Bidders Meetings will result in disqualification of the Bidder. 13.0 Bid Security, Performance Bonding and Guarantees 13.1 All Bidders are required to provide with their Bid, Bid Security in a form acceptable to and payable to the City of New Westminster. The amount of the Bid Security must be equal to ten percent (10%) of the Bid Price (excluding HST), and one of the following types: a) Bid Bond; b) Certified Cheque; c) Irrevocable Letter of Credit; or d) Bank Draft. 13.2 If, after Award of Contract, the Bidder refuses to enter into the Contract, the Bid Security (if any) may be forfeited to the City of New Westminster because of its damages, without prejudice to the City’s remedies for the Bidder’s breach of contract. 13.3 Failure to provide Bid Security (when required) will result in disqualification of the Bidder. Document #140829 CITY OF NEW WESTMINSTER Fire Alarm Panel Upgrade, Queen’s Park Arena INSTRUCTIONS TO BIDDERS Page 4 of 4 14.0 Form Of Contract 14.1 Any contract arising from this Invitation to Tender will use the CCDC 2 – 2008 Stipulated Price Contract (not bound in the tender documents) and the Supplementary Conditions included in the Tender Documents. 15.0 Ownership Of Tenders And Freedom Of Information 15.1 All documents submitted to the City of New Westminster become the property of the City, and as such, the City advises Bidders that parts, or all, of their bids may be subject to the provisions of British Columbia’s Freedom of Information and Privacy Protection Act (FOIPP) and Community Charter. Bidders who wish to protect particular parts of their bids from disclosure under the FOIPP Act should specifically identify any information or records with their bids that constitute trade secrets and that are supplied in confidence, and the release of which could significantly harm their competitive position. Information that does not meet all three of the foregoing categories may be subject to disclosure to third parties. Please refer to the Freedom of Information and Protection of Privacy Act for further information. The City, as owner of the documents submitted, retains the right to copy the documents. End of Instructions to Bidder Document #140829 CITY OF NEW WESTMINSTER Fire Alarm Panel Upgrade, Queen’s Park Arena 1.0 NWIT-10--40 BID FORM Page 1 of 4 PROJECT Title: Fire Alarm Panel Upgrade Location: Queen’s Park Arena, 51 Third Avenue, New Westminster, BC 2.0 BIDDER Name: (Hereinafter referred to as the “Bidder”) Address: (including postal code) Contact Name: Telephone No: Facsimile No: Email Address: 3.0 OWNER The Owner is the City of New Westminster, 511 Royal Avenue, New Westminster, BC, V3L 1H9, hereinafter referred to as the “City”. 4.0 OFFER 4.1 The Bidder, having examined the Bid Documents and having gained full knowledge of the scope, character and location of the work and having become familiar with the local conditions, hereby offers to the City to execute the Work for the above named project in accordance with the Bid Documents for the amount of: dollars ($ ), the contract price, which price shall be subject to adjustments as may be provided in the Tender Documents. The contract price excludes the HST (Harmonized Sales Tax). 4.2 The Contractor acknowledges that the City may, prior to contract award, negotiate changes to the scope of work with the low bidder or any one or more bidders without having any duty or obligation to advise any other bidders or to allow them to vary their bid prices due to changes to the scope of work. 5.0 ADJUSTMENTS TO CONTRACT PRICE 5.1 The Contractor further offers to carry out any changes to the work authorized by the City and to be compensated as provided in the General Conditions. Document #140829 CITY OF NEW WESTMINSTER Fire Alarm Panel Upgrade, Queen’s Park Arena NWIT-10--40 BID FORM Page 2 of 4 6.0 SCHEDULE 6.1 The Contractor offers to commence the Work and to achieve substantial performance of the Work in a manner acceptable to the City within fourteen (14) days from the date of the Notice to Proceed. 6.2 Failure to commence or complete the Work within the time stated may result in cancellation of the contract and completion of the Work by others. 7.0 ADDENDA 7.1 Any addenda issued by the City shall become part of the Bid Documents. 7.2 The Contractor acknowledges receipt of the following addenda and confirms that the Bid has been prepared in accordance therewith: Addendum No. Dated No. of Pages 8.0 SUBCONTRACTORS 8.1 The Contractor confirms that following is a list of all the subcontractors who will be employed for the Work. No other subcontractors will be employed unless prior written approval is received from the City. Name of Subcontractor Document #140829 Item of Work CITY OF NEW WESTMINSTER Fire Alarm Panel Upgrade, Queen’s Park Arena NWIT-10--40 BID FORM Page 3 of 4 9.0 CONTRACTOR NUMBERS 9.1 Contractor's WorkSafe BC Firm Number is ___________ 9.2 Contractor's City of New Westminster Business License Number is _________ (to be obtained before contract award) 10.0 REFERENCES Note: Failure to complete this section may result in disqualification. 10.1 Bidders shall provide sources for three (3) references (companies for whom work of a similar nature was done in the past two (2) years, including the City of New Westminster). 1 Company Name: Contact Person: Phone: Nature of Contract: Project Date: Approximate Value: 2 Company Name: Contact Person: Phone: Nature of Contract: Project Date: Approximate Value: 3 Company Name: Contact Person: Phone: Nature of Contract: Project Date: Approximate Value: 11.0 ACCEPTANCE 11.1 Acceptance of this offer by the City will be made by the issuance of a Letter of Award. Document #140829 CITY OF NEW WESTMINSTER Fire Alarm Panel Upgrade, Queen’s Park Arena 12.0 NWIT-10--40 BID FORM Page 4 of 4 SIGNATURES SIGNED, SEALED, AND DELIVERED by the Contractor: (Contractor's Name) (Legal Signing Authority) (Print Name and Title) (Date) End of Bid Form Document #140829 (Corporate Seal) CITY OF NEW WESTMINSTER Fire Alarm Upgrade, Queen’s Park Arena GENERAL REQUIREMENTS Page 1 of 5 1.0 Summary Of Work 1.1 The Contractor shall provide all labour, materials, products, equipment, services, and incidentals required to complete the Contract Work as indicated in the Contract Documents and amendments. 2.0 Coordination 2.1 The Contractor shall coordinate and direct the execution of the work including directing the subcontractors. 3.0 Cutting and Patching 3.1 As it is necessary to carry out the Contract Work, areas of cutting, removal, or opening up of exiting floors, walls, ceilings, or other existing site or building areas shall be fully restored to match the previously existing conditions or adjacent existing conditions in construction and finish. Obtain written approval from the structural engineer, retained and paid for by the contractor, prior to cutting, coring, and/or drilling into building structural elements. 4.0 Submittals 4.1 Pre-Construction Submittals .1 The following submittals shall be provided by the contractor for the Consultant's review within seven (7) days of award of the contract: a) Construction Schedule; b) Proof of Insurance (see General Conditions); c) Clearance Letter from WorkSafe BC 4.2 Shop Drawings & Samples .1 The Contractor shall provide to the Consultant in a timely manner prior to ordering of the material and equipment. 4.3 Submittals For Substantial Performance .1 The following submittals shall be provided by the contractor for the Consultant's review upon the Contractor's request for Certificate of Completion of the Contract: a) Final inspection certificates from the authorities having jurisdiction; b) Deficiency list, complete with a cost estimate of the value of remaining deficiencies; c) Record Set Drawings - one set of white print working drawings neatly marked up in red indicating any as-built conditions that vary from the original drawings; d) Data Manuals - 2 copies, typed 8.5” x 11” format, submitted in 3 ring hard cover binders including the following: i) List of Sub-trades; ii) Shop drawings; iii) Operation and maintenance information; iv) Warranties. Document #140831 CITY OF NEW WESTMINSTER Fire Alarm Upgrade, Queen’s Park Arena GENERAL REQUIREMENTS Page 2 of 5 5.0 Maintenance Manuals 5.1 At the time of application for Substantial Performance, provide the City with maintenance manuals as specified in the Contract Documents. 6.0 Utilities And Services 6.1 The City shall provide, at no cost to the Contractor for the related work, cold water, and electrical power. 6.2 The Contractor may use washrooms as designated by the City. 6.3 All other utilities and/or services required by the Contractor shall be the responsibility of the Contractor. 7.0 Security 7.1 The Contractor shall be responsible for the security of the job site building as related to the Work. Comply with all fire regulations during the period of construction. Leave no portion of existing buildings unlocked after public visiting hours at any time. Coordinate with the City as necessary. Except for designated public entrances, all doors will remain locked at all times. 7.2 The contractor‘s employees are to wear photo identification (provided by the City) at all times when in the work area inside the building. 8.0 Access 8.1 Coordinate with City staff prior to commencing work. Parking is available on site. 9.0 Dangerous Materials 9.1 No gasoline or other dangerous materials shall be stored on the site. 9.2 The Contractor shall separate any dangerous or hazardous materials removed from the site and take to the appropriate recycling or disposal station(s). 10.0 Site Control And Organization 10.1 The Contractor shall at all times keep the site orderly and, as work allows, generally clean. Remove all trash and debris daily. Sweep clean all floor areas in, and adjacent to, the work area on a daily basis. 11.0 Site Meetings 11.1 The Contractor shall coordinate and attend regular site meetings at such intervals as may be deemed necessary for the purpose of coordinating and expediting the progress of the work. Document #140831 CITY OF NEW WESTMINSTER Fire Alarm Upgrade, Queen’s Park Arena GENERAL REQUIREMENTS Page 3 of 5 11.2 An authorized representative of the City will attend these meetings, as and when required. The Contractor agrees to attend in person or send an authorized representative to any such meetings that the City may call. The Contractor’s subcontractors shall attend meetings as required to expedite the Work. 11.3 The Consultant shall record and distribute the minutes of any such meetings. 12.0 Pre-Construction Conference 12.1 The City shall advise the Contractor of the time and location of a pre-construction meeting that representatives of the Contractor and his trades shall attend prior to the start of any construction of this contract. The purpose of the meeting is to review site conditions, scheduling and other contractual items. 13.0 Rectify Damages 13.1 The Contractor shall make good any damage or spillage to adjacent buildings, areas, grounds, or vehicles at no cost to the City and leave the site in the same state as it was prior to commencement of the contract and to the satisfaction of the City. The Contractor shall perform all work in a manner that ensures the minimum interference with normal use of public spaces and facilities. 14.0 Rejected Work 14.1 Defective work whether the result of poor workmanship, use of defective products or damage through carelessness or other act or omission of the Contractor, shall be removed from the site by the Contractor and replaced and/or re-examined promptly in accordance with the Contract Documents, all at the Contractor's expense. 15.0 Quality Of Work 15.1 Workmanship shall be of the highest quality. When not specified elsewhere, the Contractor shall perform work in accordance with recognized trade standards and according to product manufacturer’s recommendations. 16.0 Temporary Supports 16.1 The Contractor shall be responsible for all temporary supports, bracing, or similar structural work as may be required during the carrying out of the Contract Work. 17.0 Consultation With Owner 17.1 The Contractor shall contact the City immediately: .1 For clarification regarding the Contract Work for information in addition to what is provided in the Contract Documents; .2 If any conflicts or inaccuracies are discovered in the Contract Documents; .3 If any site conditions become apparent that require revisions to the project design and Contract Documents. .4 For coordination and approval of shutdowns of building systems. The City prohibits any shutdown of building systems during normal working hours. Document #140831 CITY OF NEW WESTMINSTER Fire Alarm Upgrade, Queen’s Park Arena GENERAL REQUIREMENTS Page 4 of 5 18.0 Protection Of The Public And Others 18.1 The Contractor shall take adequate measures to protect the public, City of New Westminster staff, and others on site from injury, damage, or other loss resulting from construction and related activities. Included within the Contractor's work are hoarding, signage, and similar items appropriate for construction conditions and the progress of the job. The City shall have complete jurisdiction over entry of Contractor's workers and vehicle access to site and existing buildings. The Contractor shall make building access arrangements in consultation with applicable staff. 18.2 The Contractor will be required to meet with the City’s representative on site to review and accept responsibilities as identified in the City’s Prime Contractor Designation, Risk Assessment, and Pre-Job Meeting forms. 19.0 Hours Of Work 19.1 The Contractor shall carry out all work from 7:30 am through 7:00 pm, Monday through Friday. 19.2 The Contractor shall coordinate schedule with the applicable City staff. City staff must approve the schedule prior to the commencement of work. No workers can be on site outside of pre-approved hours. 20.0 Contractor Closeout 20.1 Final Accounting .1 Final statement of account - submit to Owner reflecting all adjustments and the following: a) Original Contract Sum; b) Additions and deductions resulting from: i) Change Orders; ii) Unit Prices; iii) Other adjustments; iv) Deductions for uncorrected work; c) Total Contract sum as adjusted; d) Previous payments; e) Sum remaining due. .2 20.2 The City retains the right to obtain proof of payment, in the form of a Statutory Declaration, of all sub-trades and material suppliers from the Contractor prior to making final payment. Project Closeout .1 Flush clear all drains affected by the work; .2 Clean site of materials and debris created by the Construction; .3 Submit written acceptance that utility companies have inspected services to their satisfaction; Document #140831 CITY OF NEW WESTMINSTER Fire Alarm Upgrade, Queen’s Park Arena .4 .5 .6 .7 GENERAL REQUIREMENTS Page 5 of 5 Provide Consultant with all Warranty and Bond Certificates with: a) The proper name and address of the Owner and of the Project; b) The date the warranty commences, which corresponds to the date of Substantial Performance; c) A clear statement of what is being warranted as referenced in the Specifications; d) The signature and seal of the company issuing the warranty, countersigned by the Contractor; Attend a final walk-through with the City and Consultant to identify any final deficiencies; Make good all known deficiencies in the work and notify the Consultant of readiness for final inspection only after completion of these items; The Consultant will review completion of deficiencies during one review only. Additional reviews required to check un-rectified deficiencies or incomplete work will be back-charged by the Owner on the Contractor’s progress payments and paid from those funds. 21.0 Special Instructions 21.1 The City does not permit smoking in or on the premises at any time. 22.0 Waste Management 22.1 The Contractor shall remove all waste from the site within forty-eight (48) hours after demolition. 22.2 The waste bins shall be located in an area that does not interfere with the normal operations of the building. 22.3 The City does not permit the use of existing on site waste receptacles by the Contractor. 22.4 Unless otherwise specified, all materials removed become the property of the Contractor, and must be disposed of in conformance with municipal, provincial, federal and WorkSafe BC requirements. 22.5 Separate recyclable and toxic waste materials from the waste stream. Deliver to a local waste management facility. End of General Requirements Document #140831 CITY OF NEW WESTMINSTER SUPPLEMENTARY GENERAL CONDITIONS CCDC-2 2008 Page 1 of 1 The Supplementary Conditions revise the General Conditions in the CCDC 2-2008 Stipulated Price Contract as follows: ARTICLE A-5 PAYMENT Paragraph 5.3 Interest – Paragraph 5.3.1 (1) – Delete “..2%..” and substitute “..0%..” Paragraph 5.3.1 (2) – Delete “..4%..” and substitute “..0%..” GENERAL CONDITIONS OF THE STIPULATED PRICE CONTRACT PART 1 GENERAL PROVISIONS GC 1.1 CONTRACT DOCUMENTS, 1.1.7.1 Between “the Agreement between the Owner and the Contractor” and “Definitions” – Insert “Addenda” PART 2 ADMINISTRATION OF THE CONTRACT GC 4.2 CONTINGENCY ALLOWANCE Delete in its entirety. PART 5 PAYMENT GC 5.1 FINANCING INFORMATION REQUIRED OF THE OWNER Delete in its entirely. GC 5.3 PROGRESS PAYMENT 5.3.2 Delete “10 calendar days” and substitute with “thirty (30) calendar days” PART 6 CHANGES IN THE WORK GC 6.2 CHANGE ORDER Add “6.2.3: The allowance for overhead and profit charged by the Contractor and subcontractors shall be as follows: .1 Cost of materials and labour plus 10% mark-up by the Contractor for changes in the work performed by the Contractor. .2 Cost of labour and materials plus 10% mark–up by the Contractor on changes in the work performed by the subcontractors. .3 Cost of labour and materials plus 10% mark-up by the subcontractors for changes in the work performed by the subcontractors. .4 The overhead and profit for changes in the work shall include supervision, administrative costs, small tools, miscellaneous materials, layout, additional bonding costs, and recording of the changes on the record drawings. PART 11 INSURANCE AND CONTRACT SECURITY GC 11.1 INSURANCE 11.1.1 .1 In line 2, after “Owner and the Consultant” insert “, sub-consultants and special consultants as identified by the Owner,” .4 In line 1, after “Owner and the Consultant” insert “, sub-consultants and special consultants as identified by the Owner,” 11.1.1.3 Delete in its entirety 11.1.1.5 Delete in its entirety CCDC 41 – CCDC INSURANCE REQUIREMENTS Delete paragraphs 3 and 5 80 40 20 10 0 650-2700 PRODUCTION WAY BURNABY, BC V5A 4X1 PH.604.676.9545 ACUMENENGINEERING.CA THIS DRAWING AND ALL ASSOCIATED DOCUMENTS ARE AN INSTRUMENT OF SERVICE AND ARE, AND WILL, AT ALL TIMES REMAIN EXCLUSIVE PROPERTY OF ACUMEN ENGINEERING LTD. ALL DESIGNS AND OTHER INFORMATION SHOWN ON THIS DRAWING ARE FOR USE ONLY ON THE SPECIFIED PROJECT; AND MAY BE USED ONLY FOR THE ISSUED PURPOSE AS STATED HEREIN. PAYMENT OF ALL SUMS DUE TO ACUMEN ENGINEERING LTD. UP TO THE DATE OF THE INTENDED USE OF THIS DRAWING IS A CONDITION PRECEDENT TO THE USE THEREOF. COPYRIGHT OF THIS DRAWING, ITS CONTENT AND DESIGN ARE RESERVED BY ACUMEN ENGINEERING LTD. THE DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED IN WHOLE, OR IN PART, WITHOUT PRIOR WRITTEN PERMISSION FROM ACUMEN ENGINEERING LTD. QUEENS PARK ARENA FIRE ALARM INITIATION ZONES: FIRE ALARM ADDRESS DEVICE 001 002 LOCATION FLOOR PULLSTATION SOUTH END SECTION #2 UPPER LEVEL PULLSTATION MEETING ROOM SOUTH UPPER LEVEL 003 PULLSTATION SOUTH END SECTION #25 UPPER LEVEL 004 PULLSTATION EAST END SECTION #24 UPPER LEVEL 005 PULLSTATION EAST END SECTION #22 UPPER LEVEL 006 PULLSTATION EAST END SECTION #18 UPPER LEVEL 007 PULLSTATION NORTH END SECTION #15 UPPER LEVEL 008 PULLSTATION WEST SIDE SECTION #9 UPPER LEVEL 009 PULLSTATION WEST SIDE SECTION #5 UPPER LEVEL 010 PULLSTATION WEST SIDE SECTION #3 UPPER LEVEL 011 PULLSTATION FRONT OFFICE LOWER LEVEL 012 PULLSTATION FRONT LOBBY MAIN ENTRANCE LOWER LEVEL 013 PULLSTATION FRONT LOBBY CENTER DOORS LOWER LEVEL 014 PULLSTATION FRONT LOBBY EAST EXIT LOWER LEVEL 015 PULLSTATION EAST SIDE EXIT/ENTRANCE LOWER LEVEL 016 PULLSTATION DRESSING ROOM #5 OUTSIDE EXIT LOWER LEVEL 017 PULLSTATION EAST DRESSING ROOM TUNNEL EXIT LOWER LEVEL 018 PULLSTATION LOWER NORTH TUNNEL EAST LOWER LEVEL 019 PULLSTATION LOWER NORTH TUNNEL WEST LOWER LEVEL 020 PULLSTATION WEST DRESSING ROOM TUNNEL EXIT LOWER LEVEL 021 PULLSTATION WEST SIDE EXIT/ENTRANCE LOWER LEVEL 022 PULLSTATION ASSISTANT'S OFFICE EXIT LOWER LEVEL 023 PULLSTATION CONCESSION STOCK ROOM LOWER LEVEL 024 PULLSTATION NORTH LOBBY EAST DOORS UPPER LEVEL 025 PULLSTATION NORTH LOBBY WEST STAIRS UPPER LEVEL 027 HEAT DETECTOR SOUTH OFFICE LOBBY UPPER LEVEL 027 HEAT DETECTOR SOUTH OFFICE #1 UPPER LEVEL 027 HEAT DETECTOR SOUTH OFFICE #2 UPPER LEVEL 027 HEAT DETECTOR SOUTH OFFICE STORAGE UPPER LEVEL 028 SMOKE DETECTOR SOUTH STAIR SECTION 2 UPPER LEVEL 029 SMOKE DETECTOR SOUTH STAIR SECTION 25 UPPER LEVEL 030 SMOKE DETECTOR NORTH STAIR SECTION 15 UPPER LEVEL 031 SMOKE DETECTOR STAIR NORTH LOBBY WEST SIDE UPPER LEVEL 032 HEAT DETECTOR LOBBY BREAKER ROOM LOWER LEVEL 033 HEAT DETECTOR ENGINE ROOM LOWER LEVEL 033 HEAT DETECTOR ENGINE ROOM LOWER LEVEL 033 PULLSTATION ENGINE ROOM LOWER LEVEL 034 AMMONIA ALARM ENGINE ROOM LOWER LEVEL 035 HEAT DETECTOR ELECTRICAL VAULT LOWER LEVEL 036 HEAT DETECTOR ELECTRICAL ROOM ENTRANCE LOWER LEVEL 037 HEAT DETECTOR ZAMBONI AREA LOWER LEVEL 037 PULLSTATION ZAMBONI AREA LOWER LEVEL 038 HEAT DETECTOR MAINTENANCE ENTRANCE LOWER LEVEL 039 HEAT DETECTOR MAINTENANCE WORK AREA LOWER LEVEL 040 WET SPRINKLER FLOW CANOPY SPRINKLERS LOWER LEVEL 041 WET SPRINKLER FLOW ARENA SPRINKLERS LOWER LEVEL 042 PRESSURE SWITCH DRY SPRINKLER LOW AIR LOWER LEVEL 043 TAMPER SWITCH CANOPY SPRINKLERS LOWER LEVEL 044 TAMPER SWITCH MAIN SPRINKLER LOWER LEVEL 045 PRESSURE SWITCH LOW WATER PRESSURE LOWER LEVEL 046 SMOKE BEAM DETECTOR ARENA WEST UPPER LEVEL 047 SMOKE BEAM DETECTOR ARENA CENTER WEST UPPER LEVEL 048 SMOKE BEAM DETECTOR ARENA CENTER EAST UPPER LEVEL 049 SMOKE BEAM DETECTOR ARENA EAST UPPER LEVEL 050 REMOTE ANNUNCIATOR STAFF ROOM - EVACUATION LOWER LEVEL 051 REMOTE ANNUNCIATOR STAFF ROOM - BELL SILENCE LOWER LEVEL FIRE ALARM UPGRADE QUEENS PARK NEW WESTMINSTER, BC Seal FIRE ALARM NOTES: 1. 2. 3. 4. 5. 026 6. 7. 8. 9. 10. 11. 12. 13. DRAWINGS SHALL BE READ IN CONJUNCTION WITH FRONT END TENDER DOCUMENTS PROVIDED BY THE CITY. ALL DOCUMENTS INCLUDING ADDENDA SHALL BE AVAILABLE ON THE CITY OF NEW WESTMINSTER WEB SITE. CONTRACTOR SHALL ATTEND MANDATORY SITE ORIENTATION MEETING, DATE AND TIME TO BE AS PER FRONT END TENDER DOCUMENTS. FAILURE TO ATTEND EXCLUDES WILL RESULT IN DISQUALIFICATION OF THE BIDDER. WHERE APPLICABLE AND WITH THE EXCEPTION OF CONCRETE CEILINGS, ALL FIRE ALARM WIRING SHALL BE RUN RECESSED IN ACCESSIBLE CEILING SPACE WHERE POSSIBLE. SURFACE MOUNTED CONDUIT OR RACEWAY SHALL BE UTILIZED FOR ALL REMAINING AREAS. FIRE ALARM SYSTEM SHALL REMAIN FULLY OPERATIONAL DURING RENOVATION. SHOULD THE SYSTEM BE SHUT DOWN DURING BUSINESS HOURS FOR ANY REASON, NOTIFY ACUMEN ENGINEERING IMMEDIATELY. FOR EXTENDED PERIODS, FIRE WATCH MAY HAVE TO BE IMPLEMENTED FOR ALL DEACTIVATED AREAS AT CONTRACTOR'S COST. EXISTING FIRE ALARM SYSTEM IS CURRENTLY MONITORED BY AN OUTSIDE SOURCE. PROVIDE FULL COORDINATION WITH MONITORING COMPANY PRIOR TO ANY WORK. FIRE ALARM SYSTEM SHALL BE FULLY OPERATIONAL AND MONITORED AFTER HOURS PRIOR TO LEAVING SITE. NOTIFY THE OWNER PRIOR TO TESTING OF ANY FIRE ALARM BELLS OR VISUAL DEVICES. NOTIFY ACUMEN ENGINEERING ON SCHEDULED FINAL FIRE ALARM VERIFICATION TO COORDINATE BETWEEN PARTIES, VERIFICATION SHALL BE WITNESSED BY CONSULTANT, FIRE AND BUILDING DEPARTMENT. AUTHORITIES MAY REQUEST TESTING OF RANDOM DEVICES ANYWHERE IN THE BUILDING OF THEIR CHOOSING. EXISTING FIRE ALARM CONTROL PANEL BEING REPLACED IS CERBERUS IDENTIFIRE NETWORK SYSTEM 2. FIRE ALARM INITIATING DEVICES COMPRISE OF MIXTURE OF CERBERUS, SIMPLEX AND EDWARDS DEVICES, ALL DEVICES SHALL BE REPLACED WITH NEW SINGLE MANUFACTURER. CITY OF NEW WESTMINSTER PREFERRED STANDARD FIRE ALARM SYSTEM IS SIMPLEX. REFER TO FIRE ALARM SPECIFICATIONS FOR PRE-APPROVED MANUFACTURERS. NEW SYSTEM SHALL BE ADDRESSABLE, SINGLE STAGE AND FULLY COMPATIBLE WITH EXISTING WIRING INFRASTRUCTURE. ALL PULLSTATIONS WITHIN ARENA AREA DESIGNATED 'PE' SHALL BE COMPLETE WITH PROTECTIVE WEATHER RESISTANT ENCLOSURE. PROVIDE ALL NECESSARY DETECTOR BASES AS REQUIRED. NEW BEAM SMOKE DETECTORS IN OPEN ARENA AREA TO BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATION. THIS INCLUDES MOUNTING HEIGHTS, MOUNTING HARDWARE, AVOIDANCE OF BANNERS/PUCK NETS/LIGHTING, ETC. TO PREVENT TROUBLE ALARMS AND TO ENSURE PROPER ACTIVATION DURING ALL SEASONS BEAM DETECTORS FORM INTEGRAL PART OF THE SYSTEM AND HAS BEEN PROBLEMATIC IN PAST WITH HUMIDITY, ROOF FLEXING, ETC. REFER TO FIRE ALARM SPECIFICATIONS FOR DETAILS. ISSUES NO. DATE # YY/MM/DD 1 10/07/16 ISSUED FOR PERMIT ONLY 2 10/08/13 ISSUED FOR TENDER REVISIONS NO. DATE # YY/MM/DD QUEEN'S PARK NEW WESTMINSTER GROUP 1; LAND DISTRICT PLAN 2620 Civic Address 51 THIRD AVENUE, NEW WESTMINSTER, B.C. Sheet Information Date Job Number 6757-E100.DWG 8/11/2010 7:44:04 AM FIRE ALARM NOTIFICATION ZONES: DEVICE LOCATION FLOOR 001 FIRE ALARM GONG AMMONIA ROOM LOWER LEVEL 001 FIRE ALARM GONG NORTH EAST TUNNEL EXIT LOWER LEVEL 001 FIRE ALARM GONG SOUTH EAST TUNNEL EXIT LOWER LEVEL 001 FIRE ALARM GONG LOBBY SOUTH WEST LOWER LEVEL 001 FIRE ALARM GONG LOBBY SOUTH EAST LOWER LEVEL 001 FIRE ALARM GONG SOUTH WALL UPPER FLOOR 001 FIRE ALARM GONG SOUTH EAST WALL UPPER FLOOR 001 FIRE ALARM GONG NORTH EAST WALL UPPER FLOOR 001 FIRE ALARM GONG TUNNEL CENTER EAST LOWER LEVEL 001 FIRE ALARM STROBE CHANGE ROOM EAST LOWER LEVEL 002 FIRE ALARM GONG ROYALS LOCKER ROOM LOWER LEVEL 002 FIRE ALARM GONG TUNNEL WEST SIDE LOWER LEVEL 002 FIRE ALARM GONG TUNNEL WEST SIDE LOWER LEVEL 002 FIRE ALARM GONG TUNNEL NORTH WEST SIDE LOWER LEVEL 002 FIRE ALARM GONG NORTH EXIT - ZAMBONI LOWER LEVEL 002 FIRE ALARM GONG NORTH EXIT - ZAMBONI STORAGE LOWER LEVEL 002 FIRE ALARM GONG NORTH EXIT - ADJACENT TO ZAMBONI LOWER LEVEL 002 FIRE ALARM GONG NORTH WALL UPPER FLOOR 002 FIRE ALARM GONG NORTH WEST WALL UPPER FLOOR 002 FIRE ALARM GONG SOUTH WEST WALL UPPER FLOOR REVISION DESCRIPTION Legal Description Drawn SIGNAL CIRCUIT ISSUE DESCRIPTION 6757 JL Checked RM Approved RM Title KEY PLAN AND SPECIFICATIONS Sheet E100 Key Plan N.T.S. QUEENS PARK ARENA 80 40 10 20 PROVIDE NEW CEILING MOUNTED COMBINATION STROBE/BUZZER IN WOOD CEILING. WIRING SHALL BE RUN VIA ACCESSIBLE CEILING ABOVE ENGINE ROOM PROVIDE NEW STROBE RECESSED IN WOOD CEILING PANEL. 0 017 DRESSING ROOM #1 FIRE ALARM DEVICES IN THIS ROOM (ZONE 33) TO HAVE SEPARATE ADDRESSES. PROVIDE ALL NECESSARY MODULES/WIRING AS REQUIRED. 033 033 S01 016 C C DRESSING ROOM #2 S01 650-2700 PRODUCTION WAY MECH PROVIDE NEW CEILING MOUNTED HEAT DETECTOR W/R 033 S01 AMMONIA DECTECTION SYSTEM N.I.C. PROVIDE VERIFICATION OF ZONE ONLY S01 WASH ROOM THIS DRAWING AND ALL ASSOCIATED DOCUMENTS ARE AN INSTRUMENT OF SERVICE AND ARE, AND WILL, AT ALL TIMES REMAIN EXCLUSIVE PROPERTY OF ACUMEN ENGINEERING LTD. ALL DESIGNS AND OTHER INFORMATION SHOWN ON THIS DRAWING ARE FOR USE ONLY ON THE SPECIFIED PROJECT; AND MAY BE USED ONLY FOR THE ISSUED PURPOSE AS STATED HEREIN. PAYMENT OF ALL SUMS DUE TO ACUMEN ENGINEERING LTD. UP TO THE DATE OF THE INTENDED USE OF THIS DRAWING IS A CONDITION PRECEDENT TO THE USE THEREOF. COPYRIGHT OF THIS DRAWING, ITS CONTENT AND DESIGN ARE RESERVED BY ACUMEN ENGINEERING LTD. THE DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED IN WHOLE, OR IN PART, WITHOUT PRIOR WRITTEN PERMISSION FROM ACUMEN ENGINEERING LTD. S01 032 STOR. FIRE ALARM ZONE #33 INPUT MODULE STOR. STOR. STOR. STOR. STOR. QUEENS PARK ARENA CUSTODIAN W/R FIRE ALARM ZONE #34 INPUT MODULE ELEC ROOM FIRE ALARM UPGRADE 014 QUEENS PARK NEW WESTMINSTER, BC PTD WASH ROOM ACUMENENGINEERING.CA 034 035 036 PH.604.676.9545 S01 LOCKER ROOM S01 VAULT MENS W/R S01 W/R BURNABY, BC V5A 4X1 PTD Seal S01 018 050 051 EXISTING REMOTE FIRE ALARM ANNUNCIATOR PANEL AND SILENCING SWITCHES TO BE REMOVED. PROVIDE NEW WIRING TO NEW ANNUNCIATOR PANEL LOCATION AS REQUIRED. STAFF ISSUES 013 S02 ZAMBONI NO. DATE # YY/MM/DD ISSUE 1 10/07/16 ISSUED FOR PERMIT ONLY 2 10/08/13 ISSUED FOR TENDER DESCRIPTION 037 FIRE ALARM ZONE #37 INPUT MODULE 037 FIRE ALARM DEVICES IN THIS ROOM (ZONE 37) TO HAVE SEPARATE ADDRESSES. PROVIDE ALL NECESSARY MODULES/WIRING AS REQUIRED. REVISIONS 019 NO. DATE # YY/MM/DD REVISION DESCRIPTION S02 012 EXISTING FIRE ALARM PANEL SEMI-RECESSED IN ASBESTOS WALL TO BE REPLACED WITH NEW ANNUNCIATOR PANEL. REUSE EXISTING WALL OPENING OR CABINET AS REQUIRED TO AVOID ASBESTOS ABATEMENT. COORDINATE WITH FIRE ALARM MANUFACTURER. S02 STOR. PROPOSED LOCATION FOR NEW FIRE ALARM PANEL c/w CONDUIT SLEEVE INTO ANNUNCIATOR PANEL FIRST AID FRONT OFFICE 011 038 OFFICE WASH ROOM STOR. STOR. STOR. STOR. STOR. STOR. OFFICE REPLACE EXISTING FIRE ALARM GONG WITH COMBINATION STROBE/BUZZER S02 S02 S02 PROVIDE NEW COMBINATION STROBE/BUZZER UNIT. MAINTENANCE PROVIDE NEW HEAT DETECTOR IN STORAGE BELOW STAIRS WOMENS W/R 039 S02 020 DRESSING ROOM #4 C S02 C PROVIDE NEW STROBE RECESSED IN WOOD CEILING PANEL. S02 DRESSING ROOM #5 MECH PROVIDE NEW CEILING MOUNTED HEAT DETECTOR LOCKER ROOM 023 OFFICE 022 SPRINKLER ROOM. SEE LAYOUT FOR DETAILS. Main Floor Plan ASBESTOS MATERIAL NOTES: ZONE 43 ZONE 42 ZONE 40 ZONE 41 ZONE 44 1. 6757-E101.DWG 3. ZONE 45 8/11/2010 7:44:07 AM 2. EXISTING SPRINKLER FLOW, TAMPER AND PRESSURE SWITCHES TO REMAIN Sprinkler Room Layout 1/4"=1'-0" WORK SHALL BE PERFORMED IN CONJUNCTION WITH THE CITY OF NEW WESTMINSTER'S AIM PROGRAM AND WORKER'S COMPENSATION BOARD REQUIREMENTS TO PREVENT THE RELEASE OF AIRBORNE ASBESTOS FIBERS. ELECTRICAL CONTRACTOR SHALL BE FAMILIAR WITH THE PRESENCE AND LOCATION OF ASBESTOS CONTAINING MATERIALS. THESE LOCATIONS HAVE BEEN IDENTIFIED (BUT NOT LIMITED TO) FLOOR TILES, GYPSUM BOARD FILLING COMPOUNDS, CEILING TILE ADHESIVES, MECHANICAL SYSTEM INSULATION, FIRESTOPPING (PACKINGS, GROUTS, PUTTIES), DUCTWORK MASTIC JOINTS, CEMENT BOARDS, FIREDOORS, ROOFING MATERIALS AND UNDERGROUND CEMENT PIPING. IN THE EVENT THAT ASBESTOS BE DISTURBED, ELECTRICAL CONTRACTOR SHALL NOTIFY THE AIM PROGRAM MANAGER IMMEDIATELY. TAKE ALL NECESSARY PRECAUTIONS TO ISOLATE THE AREA FROM THE REST OF THE BUILDING BY CLOSING DOORS AND OR ERECTING BARRIERS TO RESTRICT ACCESS. SIGNAGE SHALL BE PROVIDED AT ALL ENTRANCES TO THE AREA TO PREVENT PERSONNEL DURING CLOSED HOURS FROM INADVERTANTLY ENTERING THE AREA. ALL MECHANICAL SYSTEMS THAT ARE IN, SUPPLY OR PASS THROUGH THE AREA MUST BE SHUT DOWN AND ISOLATED. SEAL ALL INTAKE AND EXHAUST VENTS IN THE AREA WITH POLYETHYLENE AND TAPE. Renovation Legend Symbol Schedule EXISTING ELECTRICAL EQUIPMENT TO BE REMOVED AND TURNED OVER TO THE OWNER OR AS DIRECTED BY ENGINEER. REMOVE, BLANK OFF, EXTEND OR RELOCATE ALL ASSOCIATED WIRING AND MAKE SAFE. AUTOMATIC RATE OF RISE HEAT DETECTOR ANALOG TO ADDRESSABLE ZONE ADAPTER MODULE (OR EQUIVALENT) AUTOMATIC FIXED TEMP. HEAT DETECTOR SPRINKLER SYSTEM TAMPER SWITCH AUTOMATIC SMOKE DETECTOR SPRINKLER SYSTEM FLOW SWITCH EXISTING ELECTRICAL EQUIPMENT TO BE REMOVED AND RE-INSTALLED OR RELOCATED AS SHOWN UPON COMPLETION OF NEW CEILING OR WALL FINISH. REWIRE OR EXTEND WIRING AS REQUIRED. AUTOMATIC DUCT SMOKE DETECTOR SPRINKLER SYSTEM PRESSURE SWITCH AUTOMATIC SMOKE ALARM 120V FIRE ALARM END OF LINE RESISTOR AUTOMATIC SMOKE DETECTOR c/w AUX FIRE ALARM REMOTE ANNUNCIATOR EXISTING ELECTRICAL EQUIPMENT TO REMAIN IN IT'S PRESENT LOCATION. REWIRE OR EXTEND WIRING AS REQUIRED. SMOKE BEAM DETECTOR FIRE ALARM CONTROL PANEL SMOKE BEAM REFLECTOR MAGNETIC DOOR HOLDER INTERCONNECTED WITH F.A. TO RELEASE UPON ALARM EXISTING ELECTRICAL EQUIPMENT TO BE REMOVED. RE-INSTALL ALL NEW EQUIPMENT AS SHOWN. REWIRE OR EXTEND WIRING AS REQUIRED. EXISTING ELECTRICAL EQUIPMENT TO BE REMOVED AND RE-INSTALLED IN SAME LOCATION ONCE ALL OTHER WORK IS COMPLETED. FIRE ALARM MANUAL PULL STATION FIRE ALARM GONG OR BELL FIRE ALARM BUZZER FIRE ALARM STROBE LIGHT FIRE ALARM COMBINATION STROBE/BUZZER - Job Number 6757 JL Checked RM Approved RM Title FIRE ALARM ZONE #?? INPUT MODULE 3/32"=1'-0" Date Drawn STAFF 021 Sheet Information MAIN LEVEL FLOOR PLAN Sheet E101 80 40 10 20 MOUNTED ON WOOD STRUCTURE. REPLACE MOUNTING HARDWARE AS DIRECTED BY FIRE ALARM MANUFACTURER TO PREVENT TROUBLE SIGNAL AS REQUIRED. PE 006 005 221'-10" 004 S01 CONCESSION MOUNTED ON WOOD STRUCTURE. REPLACE MOUNTING HARDWARE AS DIRECTED BY FIRE ALARM MANUFACTURER TO PREVENT TROUBLE SIGNAL AS REQUIRED. 650-2700 PRODUCTION WAY SURFACE MOUNT NEW FIRE DETECTOR, EXTEND CONDUIT AND WIRING AS REQUIRED TO EXISTING ZONE. 0 S01 PE PE 049 BURNABY, BC V5A 4X1 PH.604.676.9545 ACUMENENGINEERING.CA THIS DRAWING AND ALL ASSOCIATED DOCUMENTS ARE AN INSTRUMENT OF SERVICE AND ARE, AND WILL, AT ALL TIMES REMAIN EXCLUSIVE PROPERTY OF ACUMEN ENGINEERING LTD. ALL DESIGNS AND OTHER INFORMATION SHOWN ON THIS DRAWING ARE FOR USE ONLY ON THE SPECIFIED PROJECT; AND MAY BE USED ONLY FOR THE ISSUED PURPOSE AS STATED HEREIN. PAYMENT OF ALL SUMS DUE TO ACUMEN ENGINEERING LTD. UP TO THE DATE OF THE INTENDED USE OF THIS DRAWING IS A CONDITION PRECEDENT TO THE USE THEREOF. COPYRIGHT OF THIS DRAWING, ITS CONTENT AND DESIGN ARE RESERVED BY ACUMEN ENGINEERING LTD. THE DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED IN WHOLE, OR IN PART, WITHOUT PRIOR WRITTEN PERMISSION FROM ACUMEN ENGINEERING LTD. FIRE ALARM ZONE #49 INPUT MODULE QUEENS PARK ARENA PE FIRE ALARM UPGRADE 029 003 QUEENS PARK NEW WESTMINSTER, BC PE 007 030 Seal FIRE ALARM ZONE #48 INPUT MODULE 024 249'-11" 048 MOUNTED ON CONCRETE WALL S01 MOUNTED ON WOOD STRUCTURE. REPLACE MOUNTING HARDWARE AS DIRECTED BY FIRE ALARM MANUFACTURER TO PREVENT TROUBLE SIGNAL AS REQUIRED. FIRE ALARM DEVICES IN THIS ROOM (ZONE 27) TO HAVE SEPARATE ADDRESSES. PROVIDE ALL NECESSARY MODULES/WIRING AS REQUIRED. OFFICE ISSUES OFFICE S01 027 027 027 OFFICE PROVIDE (4) NEW SMOKE DETECTORS IN CONCESSION AREA AS SHOWN. CONCESSION 027 002 NO. DATE # YY/MM/DD ISSUE 1 10/07/16 ISSUED FOR PERMIT ONLY 2 10/08/13 ISSUED FOR TENDER DESCRIPTION OFFICE FIRE ALARM ZONE #27 INPUT MODULE FIRE ALARM ZONE #47 INPUT MODULE REVISIONS 249'-11" 047 PROVIDE NEW DETECTOR SURFACE MOUNTED IN CORRIDOR. MOUNTED ON WOOD STRUCTURE. REPLACE MOUNTING HARDWARE AS DIRECTED BY FIRE ALARM MANUFACTURER TO PREVENT TROUBLE SIGNAL AS REQUIRED. NO. DATE # YY/MM/DD REVISION DESCRIPTION MOUNTED ON CONCRETE WALL PE 001 028 025 031 Sheet Information Date FIRE ALARM ZONE #46 INPUT MODULE Job Number Drawn 221'-10" MOUNTED ON WOOD STRUCTURE. REPLACE MOUNTING HARDWARE AS DIRECTED BY FIRE ALARM MANUFACTURER TO PREVENT TROUBLE SIGNAL AS REQUIRED. 046 008 S02 Upper Floor Plan PE 009 010 PE S02 PE SOUND ROOM SURFACE MOUNT NEW FIRE DETECTOR, EXTEND CONDUIT AND WIRING AS REQUIRED TO EXISTING ZONE. MOUNTED ON WOOD STRUCTURE. REPLACE MOUNTING HARDWARE AS DIRECTED BY FIRE ALARM MANUFACTURER TO PREVENT TROUBLE SIGNAL AS REQUIRED. 6757 JL Checked RM Approved RM Title UPPER LEVEL FLOOR PLAN Sheet 6757-E102.DWG 8/11/2010 7:44:10 AM 3/32"=1'-0" - E102 80 40 Fire Alarm Autodialer: 20 CONTRACTOR TO ARRANGE FOR AND COORDINATE TO ENSURE THAT FIRE ALARM SYSTEM IS CORRECTLY MONITORED VIA AN N.F.P.A. APPROVED METHOD TO A CENTRAL DEDICATED ULC-LISTED MONITORING FACILITY. REFERENCES .1 CLASS A, ZONED, NON-CODED. .1 CSA C22.1-02 - CANADIAN ELECTRICAL CODE, PART I (19TH EDITION), SAFETY STANDARD FOR ELECTRICAL INSTALLATIONS .2 .2 CAN/ULC-S524, INSTALLATION OF FIRE ALARM SYSTEMS ENCLOSURE: CSA ENCLOSURE 4, C/W LOCKABLE CONCEALED HINGED DOOR, FULL VIEWING WINDOW, FLUSH LOCK AND 2 KEYS. ENCLOSURE TO BE SUITABLE FOR SURFACE WALL MOUNTING .3 ULC-S525, AUDIBLE SIGNAL APPLIANCES FOR FIRE ALARM SYSTEMS .4 CAN/ULC-S526, VISUAL SIGNAL APPLIANCES, FIRE ALARM .5 CAN/ULC-S527, CONTROL UNITS, FIRE ALARM .6 CAN/ULC-S528, MANUAL PULL STATIONS .7 CAN/ULC-S529, SMOKE DETECTORS, FIRE ALARM .3 SPACE FOR FUTURE MODULES .8 CAN/ULC-S530, HEAT ACTUATED FIRE DETECTORS, FIRE ALARM .4 .9 CAN/ULC-S531, SMOKE ALARMS .10 CAN/ULC-S536, INSPECTION AND TESTING OF FIRE ALARM SYSTEMS LATCHING TYPE SUPERVISORY RECEIVER CIRCUITS, DISCRETE INDICATION FOR BOTH OFF-NORMAL AND TROUBLE .11 CAN/ULC-S537, VERIFICATION OF FIRE ALARM SYSTEMS .3 .4 .1 ALARM RECEIVER WITH TROUBLE AND ALARM INDICATIONS FOR CLASS A INITIATING CIRCUIT .2 SPARE ZONES: COMPATIBLE WITH SMOKE DETECTORS AND OPEN CIRCUIT DEVICES .13 CSA C22.1 SECTION 32, FIRE ALARM SYSTEMS AND FIRE PUMPS .14 LOCAL BUILDING CODE .15 CSA C22.2 NO. 0.3-01 - TEST METHODS FOR ELECTRICAL WIRES AND CABLES .16 CSA C22.2 NO. 38-95 (R2004) - THERMOSET INSULATED WIRES AND CABLES .17 NFPA 72E _ AUTOMATIC FIRE DETECTORS .18 NFPA 72G _ NOTIFICATION APPLIANCES FOR PROTECTIVE SIGNALLING SYSTEMS .1 NFPA 72H _ GUIDE FOR TEST PROCEDURES FOR PROTECTIVE SIGNALLING SYSTEMS .2 "POWER TROUBLE" INDICATION .3 "GROUND TROUBLE" INDICATION .20 NFPA 101 _ LIFE SAFETY CODE .4 "REMOTE ANNUNCIATOR TROUBLE" INDICATION .21 UNDERWRITERS LABORATORIES OF CANADA - LISTINGS .5 "SYSTEM TROUBLE" INDICATION .22 UNDERWRITERS LABORATORIES, INC., - LISTINGS .6 "SYSTEM TROUBLE" BUZZER AND SILENCE SWITCH C/W TROUBLE RESOUND FEATURE .7 SYSTEM RESET SWITCH .8 "LED TEST" SWITCH IF APPLICABLE .9 "ALARM SILENCE" SWITCH TO SILENCE SIGNALS MANUALLY. IF NEW ALARM OCCURS AFTER SIGNALS HAVE BEEN SILENCED, SIGNALS TO RESOUND .6 .7 PANEL TO BE COMPLETE WITH MINIMUM (BUT NOT LESS THAN REQUIRED BY LOAD) OF 4 SIGNAL CIRCUITS WIRED IN A CLASS A CONFIGURATION (UP TO 1.7A PER SIGNAL CIRCUIT). COMMON CONTROL AND POWER UNITS: .1 FIRE ALARM SYSTEM: FULLY ADDRESSABLE LOCAL FIRE ALARM SYSTEM WITH CONNECTIONS TO REMOTE CENTRAL MONITORING STATION AND (2) REMOTE LCD ANNUNCIATOR PANELS. SYSTEM INCLUDES BUT IS NOT LIMITED TO: .1 1.3 CONTROL PANEL TO CARRY OUT FIRE ALARM AND PROTECTION FUNCTIONS INCLUDING RECEIVING ALARM SIGNALS, INITIATING GENERAL ALARM, SUPERVISING SYSTEM CONTINUOUSLY, ACTUATING ZONE ANNUNCIATOR AND INITIATING TROUBLE SIGNALS. .2 TROUBLE SIGNAL DEVICES .3 POWER SUPPLY FACILITIES .4 MANUAL ALARM STATIONS .5 AUTOMATIC ALARM INITIATING DEVICES .6 AUDIBLE SIGNAL DEVICES .7 END-OF-LINE DEVICES .8 REMOTE ANNUNCIATOR PANEL .9 VISUAL ALARM SIGNAL DEVICES .10 ANCILLARY DEVICES .3 FIRE DEPARTMENT AND REMOTE MONITORING: TEST REPORTS: INDICATE SATISFACTORY COMPLETION OF REQUIRED TESTS AND INSPECTIONS .3 MANUFACTURER'S INSTALLATION INSTRUCTIONS: INDICATE APPLICATION CONDITIONS AND LIMITATIONS OF USE STIPULATED BY PRODUCT TESTING AGENCY. INCLUDE INSTRUCTIONS FOR STORAGE, HANDLING, PROTECTION, EXAMINATION, PREPARATION, INSTALLATION, AND STARTING OF PRODUCTS. 1.4 .9 .10 .11 PROVIDE OPERATION AND MAINTENANCE DATA FOR FIRE ALARM SYSTEM FOR INCORPORATION INTO MANUAL. INCLUDE: .1 .2 .3 .4 1.5 OPERATION AND MAINTENANCE AND REPAIR INSTRUCTIONS FOR COMPLETE FIRE ALARM SYSTEM TO PERMIT EFFECTIVE OPERATION AND MAINTENANCE .2 1.6 MANUFACTURER: COMPANY SPECIALIZING IN MANUFACTURING THE PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM 10 YEARS DOCUMENTED EXPERIENCE, AND WITH SERVICE FACILITIES WITHIN 160 KM FROM PROJECT SITE. PROVIDE PRODUCTS LISTED AND CLASSIFIED BY ULC .2 VERIFICATION COMPANY/FIRM SHALL BE ACCEPTABLE TO AUTHORITY HAVING JURISDICTION 1.7 1.8 .1 .2 1.9 .1 .2 PART 2 2.1 .1 .17 TROUBLE SIGNAL SEQUENCE OF OPERATION: SYSTEM OR CIRCUIT TROUBLE PLACES SYSTEM IN TROUBLE MODE, WHICH CAUSES THE FOLLOWING SYSTEM OPERATIONS: .2 VISUAL AND AUDIBLE TROUBLE ALARM INDICATED AT REMOTE ANNUNCIATOR PANEL. .3 TROUBLE SIGNAL TRANSMITTED TO REMOTE STATION. .4 MANUAL ACKNOWLEDGE FUNCTION AT FIRE ALARM CONTROL PANEL SILENCES AUDIBLE TROUBLE ALARM; VISUAL ALARM IS DISPLAYED UNTIL INITIATING FAILURE OR CIRCUIT TROUBLE IS CLEARED. VISUAL AND AUDIBLE TROUBLE ALARM INDICATED AT REMOTE ANNUNCIATOR PANEL. .3 TROUBLE SIGNAL TRANSMITTED TO REMOTE STATION. .4 MANUAL ACKNOWLEDGE FUNCTION AT FIRE ALARM CONTROL PANEL SILENCES AUDIBLE TROUBLE ALARM; VISUAL ALARM IS DISPLAYED UNTIL INITIATING FAILURE OR CIRCUIT TROUBLE IS CLEARED. ALARM SEQUENCE OF OPERATION: ACTUATION OF INITIATING DEVICE PLACES CIRCUIT IN ALARM MODE, WHICH CAUSES THE FOLLOWING SYSTEM OPERATIONS: .4 ACTIVATE BUILDING SMOKE REMOVAL SYSTEM (IF APPLICABLE) .5 TRANSMIT SIGNAL TO BUILDING MECHANICAL SYSTEMS TO INITIATE SHUTDOWN OF FANS AND DAMPER OPERATION (IF APPLICABLE) .6 TRANSMIT SIGNAL TO RELEASE DOOR HOLD OPEN DEVICES. MANUAL PULL STATIONS: TO CAN/ULC-S528 .7 THERMAL DETECTORS: TO CAN/ULC-S530 .8 SMOKE DETECTORS: TO CAN/ULC-S529 .9 SMOKE ALARMS: TO CAN/ULC-S531 .20 ALARM RESET: SYSTEM REMAINS IN ALARM MODE UNTIL MANUALLY RESET WITH KEY ACCESSIBLE RESET FUNCTION. .21 LAMP TEST: MANUAL LAMP TEST FUNCTION CAUSES ALARM INDICATION AT EACH ZONE AT FIRE ALARM CONTROL PANEL AND AT ANNUNCIATOR PANEL. SYSTEM OPERATION OPERATION OF ANY ALARM INITIATING DEVICE TO: .1 CAUSE AUDIBLE SIGNAL DEVICES TO SOUND THROUGHOUT BUILDING. .2 TRANSMIT SIGNAL TO FIRE DEPARTMENT VIA FIRE ALARM AUTODIALER TO REMOTE MONITORING STATION. .3 CAUSE ZONE OF ALARM DEVICE TO BE INDICATED ON CONTROL PANEL AND REMOTE ANNUNCIATOR. .4 CAUSE AIR CONDITIONING AND VENTILATING FANS TO SHUT DOWN OR TO FUNCTION SO AS TO PROVIDE REQUIRED CONTROL OF SMOKE MOVEMENT. .5 CAUSE FIRE DOORS AND SMOKE CONTROL DOORS IF NORMALLY HELD OPEN, TO CLOSE AUTOMATICALLY. PRE-APPROVED MANUFACTURERS .1 .2 ALL EQUIPMENT AND DEVICES WILL BE ULC LISTED AND LABELLED AND SUPPLIED BY A SINGLE MANUFACTURER .6 2.3 VISUAL AND AUDIBLE TROUBLE ALARM INDICATED (BY ZONE) AT FIRE ALARM CONTROL PANEL. INDICATE LOCATION OF ALARM ZONE ON FIRE ALARM CONTROL PANEL AND ON REMOTE ANNUNCIATOR PANEL VISUAL SIGNAL DEVICES: TO CAN/ULC-S526 .1 .1 .3 CONTROL UNIT: TO CAN/ULC-S527 MIRCOM, EDWARDS, SIMPLEX, NOTIFIER .22 DRILL SEQUENCE OF OPERATION: MANUAL DRILL FUNCTION CAUSES ALARM MODE OPERATION AS DESCRIBED ABOVE. .23 ZONING: AS INDICATED ON THE DRAWINGS AND AS REQUIRED. 2.5 POWER SUPPLY .1 .2 MAKE CONDUIT AND WIRING CONNECTIONS TO DOOR RELEASE DEVICES, SPRINKLER FLOW SWITCHES, SPRINKLER VALVE TAMPER SWITCHES, DUCT SMOKE DETECTORS AND ANY OTHER DEVICES AS REQUIRED. .6 INSTALL SYSTEMS IN ACCORDANCE WITH CAN/ULC-S524. .7 USE ISOLATION MODULES AS REQUIRED TO ISOLATE TROUBLE FOR SEPARATE ZONES. .8 INSTALL MAIN CONTROL PANEL AND CONNECT TO AC POWER SUPPLY, AND DC STANDBY POWER. .9 LOCATE AND INSTALL MANUAL ALARM STATIONS AND CONNECT TO ALARM CIRCUIT WIRING. .10 LOCATE AND INSTALL DETECTORS AND CONNECT TO ALARM CIRCUIT WIRING. DO NOT MOUNT DETECTORS WITHIN 1 M OF AIR OUTLETS. MAINTAIN AT LEAST 600 MM RADIUS CLEAR SPACE ON CEILING, BELOW AND AROUND DETECTORS. LOCATE DUCT TYPE DETECTORS IN STRAIGHT PORTIONS OF DUCTS. .11 CONNECT ALARM CIRCUITS TO MAIN CONTROL PANEL. .12 LOCATE AND INSTALL AUDIBLE SIGNAL AND VISUAL SIGNAL DEVICES AND CONNECT TO SIGNALLING CIRCUITS. .13 CONNECT SIGNALLING CIRCUITS TO MAIN CONTROL PANEL. .14 INSTALL END-OF-LINE DEVICES AT END OF ALARM AND SIGNALLING CIRCUITS, IN A SEPARATE BOX NOT MORE THAN 1730 MM ABOVE FINISHED FLOOR. .15 INSTALL REMOTE ANNUNCIATOR PANELS AND CONNECT TO ANNUNCIATOR CIRCUIT WIRING. 4.2 WIRING .4 .5 4.3 .1 .2 120 V, AC, 60 HZ INPUT, 24 V DC OUTPUT FROM RECTIFIER TO OPERATE ALARM AND SIGNAL CIRCUITS. INCLUDE SURGE PROTECTION ON INCOMING POWER WIRING. STANDBY SLA (SEALED LEAD ACID) BATTERY UNIT WITH AUTOMATIC BATTERY CHARGER TO PROVIDE SUPERVISORY AND TROUBLE SIGNAL CURRENT FOR 24 HOURS, PLUS GENERAL ALARM LOAD FOR MINIMUM OF 30 MINUTES. UNIT TO BE SIZED TO CARRY THE COMPLETE FULL LOAD OF FIRE ALARM SYSTEM. ALARM INITIATING DEVICES TO BE WIRED WITH MULTI CONDUCTOR #18 RW90 CABLES AS REQUIRED IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE. CIRCUIT RESISTANCE SHALL NOT EXCEED 50 OHMS. CONTRACTOR TO ENSURE AUTODIALER IS TESTED AND INSPECTED DURING THE FIRE ALARM VERIFICATION AND IS REPORTED ON THE WORKSHEETS. 4.5 .1 QUEENS PARK NEW WESTMINSTER, BC 1.0 .01 .02 .03 .04 .05 .06 .07 .08 .09 .10 .13 .14 .2 .3 .15 .16 VERIFICATION AND CERTIFICATION .17 THE MANUFACTURER SHALL MAKE AN INSPECTION OF THE FIRE ALARM EQUIPMENT, INCLUDING THOSE COMPONENTS NECESSARY TO THE DIRECT OPERATION OF THE SYSTEM SUCH AS DETECTORS AND CONTROLS, WHETHER OR NOT MANUFACTURED BY THE MANUFACTURER ADDED UNDER THIS CONTRACT. THE INSPECTOR SHALL COMPRISE AN EXAMINATION OF SUCH EQUIPMENT FOR THE FOLLOWING: .18 THAT THE TYPE OF EQUIPMENT INSTALLED IS THAT DESIGNATED BY THE SPECIFICATION THAT THE WIRING CONNECTIONS TO ALL EQUIPMENT COMPONENTS SHOW THAT THE INSTALLER UNDERTOOK TO HAVE OBSERVED ULC AND CSA REQUIREMENTS THAT EQUIPMENT OF THE MANUFACTURER'S MANUFACTURE HAS BEEN INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND THAT ALL SIGNALLING DEVICES OF WHATEVER MANUFACTURE HAVE BEEN OPERATED OR TESTED TO VERIFY THEIR OPERATION .4 THAT THE SUPERVISORY WIRING OF THOSE ITEMS OF EQUIPMENT CONNECTED TO A SUPERVISED CIRCUIT IS OPERATING AND THAT THE GOVERNMENTAL REGULATIONS, IF ANY, CONCERNING SUCH SUPERVISORY WIRING HAVE BEEN MET TO THE SATISFACTION OF INSPECTING OFFICIALS .5 TO ASSIST THE CONTRACTOR IN PREPARING HIS BID THE MANUFACTURER SHALL INDICATE THE NUMBER OF HOURS NECESSARY TO COMPLETE THIS INSPECTION PRIOR TO CLOSING OF TENDERS, AND THE NUMBER OF HOURS NECESSARY TO PROVIDE A SEMINAR ON THE SYSTEM FOR THE BUILDING OWNER .2 TEST, VERIFY AND COMMISSION THE SYSTEM ACCORDING TO REQUIREMENTS OF CAN/ULC_S537 STANDARD FOR VERIFICATION OF FIRE ALARM SYSTEM INSTALLATIONS CAN/ULC-S524, INSTALLATION OF FIRE ALARM SYSTEMS. THE SERVICES OF THE CONTRACTOR AND REPRESENTATIVES OF THE FIRE ALARM MANUFACTURER ARE REQUIRED FOR THE VERIFICATION Seal General Specifications CLASS A CIRCUITS. .1 FIRE ALARM UPGRADE THE CONTRACTOR SHALL COORDINATE TO ENSURE THE MONITORING COMPANY SUBMITS TO THE ENGINEER A LETTER CONFIRMING THE FOLLOWING: A. MONITORING OF FIRE ALARM, SPRINKLER SUPERVISORY AND FIRE ALARM SYSTEM TROUBLE SIGNALS B. USE OF ULC-LISTED FIRE TRANSPONDERS, ETC. C. USE AND TYPE OF DEDICATED TELEPHONE LINES. .12 INCLUDE SERVICES OF CERTIFIED TECHNICIAN TO SUPERVISE INSTALLATION, ADJUSTMENTS, FINAL CONNECTIONS, AND SYSTEM TESTING. QUEENS PARK ARENA BREAKER FOR FIRE ALARM PANEL AND AUTODIALER TO BE PAINTED RED. PROVIDE LAMICOID LABELS TO READ: "FIRE ALARM-DO NOT OPEN EXCEPT TO TEST" AND "FIRE ALARM DIALER-DO NOT OPEN EXCEPT TO TEST". MANUFACTURER'S FIELD SERVICES .1 THIS DRAWING AND ALL ASSOCIATED DOCUMENTS ARE AN INSTRUMENT OF SERVICE AND ARE, AND WILL, AT ALL TIMES REMAIN EXCLUSIVE PROPERTY OF ACUMEN ENGINEERING LTD. ALL DESIGNS AND OTHER INFORMATION SHOWN ON THIS DRAWING ARE FOR USE ONLY ON THE SPECIFIED PROJECT; AND MAY BE USED ONLY FOR THE ISSUED PURPOSE AS STATED HEREIN. PAYMENT OF ALL SUMS DUE TO ACUMEN ENGINEERING LTD. UP TO THE DATE OF THE INTENDED USE OF THIS DRAWING IS A CONDITION PRECEDENT TO THE USE THEREOF. COPYRIGHT OF THIS DRAWING, ITS CONTENT AND DESIGN ARE RESERVED BY ACUMEN ENGINEERING LTD. THE DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED IN WHOLE, OR IN PART, WITHOUT PRIOR WRITTEN PERMISSION FROM ACUMEN ENGINEERING LTD. CONTRACTOR SHALL USE EXISTING AUTODIALER LEASED TELEPHONE LINE AND CONNECTIONS TO AUTODIALER AS REQUIRED. SIMULATE GROUNDS AND BREAKS ON ALARM AND SIGNALLING CIRCUITS TO ENSURE PROPER OPERATION OF SYSTEM. TEST EACH CONDUCTOR ON ALL CIRCUITS FOR CAPABILITY OF PROVIDING ALARM SIGNAL DURING GROUND-FAULT CONDITION IMPOSED NEAR MIDMOST POINT OF CIRCUIT. RESET CONTROL UNIT AFTER EACH ALARM FUNCTION AND CORRECT IMPOSED FAULT AFTER COMPLETION OF EACH TEST. PH.604.676.9545 ACUMENENGINEERING.CA FIELD QUALITY CONTROL TEST EACH CONDUCTOR ON ALL CIRCUITS FOR CAPABILITY OF PROVIDING ALARM SIGNAL ON EACH SIDE OF SINGLE OPEN-CIRCUIT FAULT CONDITION IMPOSED NEAR MIDMOST POINT OF CIRCUIT. RESET CONTROL UNIT AFTER EACH ALARM FUNCTION AND CORRECT IMPOSED FAULT AFTER COMPLETION OF EACH TEST. 650-2700 PRODUCTION WAY BURNABY, BC V5A 4X1 DEVICES SHALL INCLUDE BUT NOT BE LIMITED TO FIRE ALARM PANEL INCLUDING ALL NECESSARY ADDITIONAL MODULES, AUTO DIALER, ULC-LISTED TRANSPONDER. SILENT KNIGHT MODEL #5104 FIRE CONTROL COMMUNICATOR OR APPROVED ULC-LISTED SHALL BE USED. .11 .2 4.4 THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL NECESSARY DEVICES TO ALLOW FOR CORRECT MONITORING OF: - FIRE ALARM SPRINKLER ACTIVATED - FIRE ALARM NON-SPRINKLER ACTIVATED - FIRE ALARM SYSTEM TROUBLE, AND - SPRINKLER SUPERVISORY SIGNALS ALL WIRING WILL BE TERMINATED INTO THE TERMINAL STRIPS IN THE FIRE ALARM CABINET WITH ALL WIRING FULLY LABELLED. ALL CABLING TO BE NEAT WITH CABLES BUNDLED AND WRAPPED INSIDE THE CABINETS. NO SPLICING WILL BE ALLOWED WITHIN THE CABINETS. A COMPLETE SCHEDULE OF ALL WIRING TERMINATIONS WILL BE MOUNTED INSIDE EACH CONTROL UNIT. A COMPLETE SCHEMATIC WITH ALL DEVICES, CABLE LABELLING INFORMATION, DESTINATIONS, ETC. WILL BE INCLUDED WITH THE SHOP DRAWINGS. .1 SUPERVISORY SIGNAL SEQUENCE OF OPERATION: SYSTEM OR CIRCUIT TROUBLE PLACES SYSTEM IN TROUBLE MODE, WHICH CAUSES THE FOLLOWING SYSTEM OPERATIONS: GENERAL .5 2.2 VISUAL AND AUDIBLE TROUBLE ALARM INDICATED (BY ZONE) AT FIRE ALARM CONTROL PANEL. TRANSMIT SIGNAL TO REMOTE STATION EQUIPMENT .4 .5 SIGNAL CIRCUITS TO BE WIRED WITH A MINIMUM 2 - #14 RW90 PER ZONE. IN NO CASE SHALL THE VOLTAGE DROP TO ANY SIGNAL EXCEED 3%. .2 AUDIBLE SIGNAL DEVICES: TO ULC-S525 MOUNT OUTLET BOX FOR ELECTRIC DOOR HOLDER TO WITHSTAND 36 KG PULLING FORCE. .3 PRODUCTS POWER SUPPLY: TO CAN/ULC-S524 .4 ENSURE CONDUCTORS ARE ROUTED IN SUCH A MANNER TO PROVIDE REQUIRED FIRE RATING. SOUND AND DISPLAY LOCAL FIRE ALARM SIGNALLING DEVICES WITH TEMPORAL CODE SIGNAL .3 MOUNT END_OF_LINE DEVICE IN BOX WITH LAST DEVICE OR SEPARATE BOX ADJACENT TO LAST DEVICE IN CIRCUIT. .2 .1 .2 .3 USE COMMUNICATION CHANNEL CLASS A (ADDRESSABLE SYSTEM) PROVIDE TROUBLE ACKNOWLEDGE, DRILL, AND ALARM SILENCE SWITCH. PROVIDE (5) SPARE SMOKE AND (5) SPARE HEAT DETECTORS USE 14 AWG MINIMUM SIZE CONDUCTORS FOR FIRE ALARM DETECTION AND SIGNAL CIRCUIT CONDUCTORS. .1 POWER SUPPLY: ADEQUATE TO SERVE CONTROL PANEL MODULES, REMOTE ANNUNCIATOR, DOOR HOLDERS, SMOKE DAMPERS, RELAYS, AND ALARM SIGNALLING DEVICES. INCLUDE BATTERY OPERATED EMERGENCY POWER SUPPLY WITH CAPACITY FOR OPERATING SYSTEM IN STANDBY MODE FOR 24 HOURS FOLLOWED BY ALARM MODE FOR 30 MINUTES. .16 PROVIDE 10 MANUAL STATION BREAK_GLASS RODS .2 MOUNT BATTERY PACK AND CHARGER IN THE CONTROL CABINET. AUXILIARY RELAYS: PROVIDE SUFFICIENT SPDT AUXILIARY RELAY CONTACTS TO PROVIDE ACCESSORY FUNCTIONS SPECIFIED. .19 INSTALL PRODUCTS TO MANUFACTURER'S WRITTEN INSTRUCTIONS. .19 A REPRESENTATIVE FROM THE MANUFACTURERS SHALL ATTEND THE SEMINAR EXTRA MATERIALS .1 SPRINKLER SYSTEM: WIRE ALARM AND SUPERVISORY SWITCHES AND CONNECT TO CONTROL PANEL. .15 ARRANGE AND PAY FOR TWO ON-SITE LECTURES AND DEMONSTRATIONS BY FIRE ALARM EQUIPMENT MANUFACTURER TO TRAIN OPERATIONAL PERSONNEL IN USE AND MAINTENANCE OF FIRE ALARM SYSTEM. SEMINARS WILL USE ACTUAL DEMONSTRATION. PREFERRED UNIT IS MIRCOM BEAM200SA OR APPROVED EQUAL. .18 REMOTE STATION SIGNAL TRANSMITTER: EXISTING TO REMAIN. TRAINING .8 LIST EACH AUXILIARY DEVICE, SUCH AS DOOR HOLDERS, DAMPERS, AND EXTERNAL RELAYS THAT MUST BE OPERATED FROM THE FIRE ALARM CONTROL PANEL POWER SUPPLY. .14 .18 MINIMUM OF 4 SENSITIVITY LEVELS WITH ABILITY TO AUTOMATICALLY ADJUST TO SUIT ENVIRONMENT. LOCATE AND INSTALL REMOTE RELAY UNITS TO CONTROL FAN SHUT DOWN. .1 PROVIDE SERVICE AND MAINTENANCE OF FIRE ALARM SYSTEM FOR ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION INTEGRAL SIGNAL STRENGTH INDICATION VIA DIGITAL DISPLAY. .7 .17 MAINTENANCE SERVICE .1 .6 LOCATE AND INSTALL DOOR RELEASING DEVICES. REGULATORY REQUIREMENTS .1 COMPLETE WITH LOCAL ALARM, TROUBLE AND NORMAL STATUS LED INDICATORS. .16 CONSULT MUNICIPAL FIRE SERVICE TO DETERMINE AVAILABILITY OF MUNICIPAL CONNECTION, OR CHOOSE EITHER REMOTE STATION OR CENTRAL STATION SYSTEM. CONSULT WITH MANUFACTURER AND REMOTE STATION SERVICE PROVIDER TO DETERMINE REQUIREMENTS. INSTALLER: COMPANY SPECIALIZING IN INSTALLING THE PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM 5 YEARS DOCUMENTED EXPERIENCE, AND CERTIFIED BY PROVINCE OF BC AS FIRE ALARM INSTALLER. .5 CONTROL PANEL: MODULAR CONSTRUCTION WITH SURFACE WALL MOUNTED ENCLOSURE. .13 COPY OF APPROVED SHOP DRAWINGS LIST OF RECOMMENDED SPARE PARTS FOR SYSTEM CONTACT TERMINAL SIZE: CAPABLE OF ACCEPTING 22-12 AWG WIRE. SYSTEM SUPERVISION: COMPONENT OR POWER SUPPLY FAILURE PLACES SYSTEM IN TROUBLE MODE. TECHNICAL DATA - ILLUSTRATED PARTS LISTS WITH PARTS CATALOGUE NUMBERS COMPLETE WITH INTEGRAL SENSITIVITY TEST FILTER AND EXTERNAL POWER SUPPLY. UNIT SHALL HAVE LOCAL TEST AND RESET SWITCHES. INSTALLATION CONTACTS: 1.0 A, 28V, FOR FUNCTIONS SUCH AS RELEASE OF DOOR HOLDERS OR INITIATION OF FAN SHUT DOWN. .12 QUALIFICATIONS .1 FIRE DEPARTMENT BYPASS SWITCH C/W INDICATOR FOR TROUBLE AT PANEL. .2 OPERATION AND MAINTENANCE DATA .1 .2 .1 PRODUCT DATA: PROVIDE ELECTRICAL CHARACTERISTICS AND CONNECTION REQUIREMENTS .2 PANEL TO INCLUDE; ALARM, SPRINKLER FLOW, SUPERVISORY, AND TROUBLE RELAYS FOR REMOTE MONITORING CONNECTIONS. HUMIDITY FACTOR OF 10 TO 93% NONCONDENSING. .4 4.1 AUXILIARY RELAYS: PLUG-IN TYPE, DUST COVER, SUPERVISED AGAINST UNAUTHORIZED REMOVAL BY COMMON TROUBLE CIRCUIT AND C/W INDIVIDUAL BYPASS SWITCH. SUBMITTALS .1 .1 .3 EXECUTION "SIGNALS SILENCED" INDICATION MASTER POWER SUPPLY PANEL TO PROVIDE 24 V DC TO SYSTEM FROM 120 V AC, 60 HZ INPUT. BE COMPLETE WITH LONG RANGE ACCESSORIES OR REFLECTORS AS NECESSARY TO SUIT BEAM DISTANCES AS SHOWN ON DRAWINGS. PART 4 "POWER ON" LED (GREEN) TO MONITOR PRIMARY SOURCE OF POWER TO SYSTEM .2 BEAM SMOKE DETECTORS BEAM SMOKE DETECTORS SHALL: BE COMPLETE WITH HEATER TO SUIT TEMPERATURES BELOW 5 DEGREES CELCIUS. UNIT TEMPERATURE RANGE SHALL BE BETWEEN -30 TO 55 DEGREES CELCIUS. .2 CONTROL AND ANNUNCIATOR PANELS CONTAINING FOLLOWING INDICATIONS AND CONTROLS: .10 .8 .1 PANEL SIGNAL CIRCUITS TO PROVIDE TEMPORAL SOUND RATE UPON ANY ALARM INITIATION. SYSTEM DESCRIPTION .1 3.1 ALARM RECEIVER PANEL WITH TROUBLE AND ALARM INDICATIONS FOR CLASS A INITIATING CIRCUIT. NBC, NATIONAL BUILDING CODE OF CANADA .5 PART 3 SUPERVISED, MODULAR DESIGN WITH PLUG-IN MODULES: .12 1.2 6757-E103.DWG FIRE ALARM CONTROL PANEL GENERAL 1.1 .19 8/11/2010 7:44:25 AM 2.4 PART 1 0 10 FIRE ALARM SPECIFICATIONS: .19 .20 .21 .22 .23 .24 .25 .27 .28 .29 GENERAL PROVISIONS THE GENERAL CONDITIONS OF THE CONTRACT SHALL FORM AN INTEGRAL PART OF THE SPECIFICATION. PROVIDE ALL LABOUR AND MATERIALS NECESSARY FOR COMPLETE AND OPERATING SYSTEMS AS INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN. ANY WORK, AND MATERIAL, EVEN IF NOT SHOWN OR SPECIFIED, WHICH IS OBVIOUSLY NECESSARY OR REASONABLY IMPLIED TO COMPLETE THE WORK, SHALL BE PROVIDED AS IF IT WAS BOTH SHOWN, AND SPECIFIED. ALL ELECTRICAL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE NATIONAL BUILDING CODE, ELECTRICAL SAFETY ACT OF THE PROVINCE OF BRITISH COLUMBIA, CURRENT PURSUANT REGULATION (B.C. ELECTRICAL CODE REGULATION, ELECTRICAL SAFETY BULLETINS, ETC.), TO THE SATISFACTION OF THE LOCAL INSPECTION AUTHORITY HAVING JURISDICTION AND TO THE APPROVAL OF THE CONSULTANT. WHERE, IN THE FOLLOWING CLAUSES OF THE SPECIFICATION, REFERENCE IS MADE TO THE "CANADIAN ELECTRICAL CODE", IT SHALL REFER TO THE CURRENT EDITIONS OF THE NATIONAL BUILDING CODE, ELECTRICAL SAFETY ACT AND REGULATIONS AS STATED ABOVE. THE CONTRACTOR SHALL VISIT THE SITE AND ASCERTAIN CONDITIONS AFFECTING THE WORK PRIOR TO SUBMITTING A TENDER QUOTE. REFER TO TENDER DOCUMENTS FOR SCHEDULED DATE AND TIME. NO EXTRAS FOR WORK WILL BE PAID UNLESS AUTHORIZED BY THE ARCHITECT OR OWNER. ALL WORK SHALL CONFORM TO THE CURRENT EDITION OF THE CANADIAN ELECTRICAL CODE, BUILDING CODE, NATIONAL BUILDING CODE AND LOCAL, MUNICIPAL AND PROVINCIAL CODES, BY-LAWS AND REGULATIONS. THE CONTRACTOR SHALL APPLY FOR ALL PERMITS, SERVICES, AND INSPECTIONS, AND PAY FOR ALL FEES TO THE AUTHORITIES HAVING JURISDICTION. INCLUDE ALL COSTS IN TENDER QUOTE. OBTAIN APPROVALS FROM THE ELECTRICAL INSPECTION AUTHORITY AND NOTIFY THE CONSULTANT OF ANY CHANGES REQUESTED IN THE DESIGN PLANS AND SPECIFICATIONS BY THE LOCAL INSPECTION AUTHORITY. INCLUDE ALL COSTS TO ACCOMMODATE THESE CHANGES IN TENDER QUOTE. CHECK DRAWINGS AND SPECIFICATIONS FOR ERRORS, OMISSIONS AND CONFORMITY WITH APPLICABLE REGULATIONS PRIOR TO TENDER SUBMISSION. REPORT DISCREPANCIES TO CONSULTANT PRIOR TO TENDER CLOSING, OR INCLUDE ALLOWANCE IN TENDER PRICE TO COVER COST OF REQUIRED CORRECTION. WHERE DOUBT EXISTS AS TO THE MEANING TO THE DRAWINGS OR SPECIFICATIONS, OBTAIN CLARIFICATION PRIOR TO TENDER SUBMISSION OR BASE TENDER PRICE ON MOST EXPENSIVE INTERPRETATION OF DISCREPANCY. ALL WORK SHALL BE SUBJECT TO REVIEW AND APPROVAL BY THE CONSULTANT. IN THE EVENT A REQUESTED FINAL REVIEW REVEALS DEFICIENCIES, THE CONTRACTOR SHALL TAKE ALL REASONABLE STEPS TO COMPLETE ALL DEFICIENCIES PRIOR TO THE SUBSEQUENT REVISIT AND DEFICIENCY REVIEW BY THE CONSULTANT. WHERE THE CONTRACTOR HAS NOT COMPLETED ALL DEFICIENCIES, AND THE CONSULTANT IS REQUESTED TO ATTEND THE SITE FOR DEFICIENCY SIGN OFF, THE CONTRACTOR SHALL BE LIABLE TO THE CONSULTANT'S FOR THE COSTS OF THE REVIEW AT NORMAL HOURLY RATES, PLUS REIMBURSABLE EXPENSES AND THE COST OF AN ADDITIONAL REVIEW WHICH MAY BE REQUIRED AT DEFICIENCY COMPLETION. THE CONTRACTOR SHALL SUPPLY, INSTALL, WIRE AND CONNECT ALL EQUIPMENT AS SPECIFIED, SHOWN AND/OR AS REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION. SHOP DRAWINGS FOR ELECTRICAL EQUIPMENT AND FIXTURES SHALL BE SUBMITTED FOR REVIEW BY CONSULTANT PRIOR TO MANUFACTURER OR INSTALLATION. CORRECTIONS OR COMMENTS MADE ON THE SHOP DRAWINGS DURING THIS REVIEW DO NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. THIS REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR: CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS; SELECTING FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION; COORDINATING ALL WORK WITH THAT OF ALL OTHER TRADES AND PERFORMING ALL WORK IN A SAFE AND SATISFACTORY MANNER. INCLUDE ALL FEDERAL, PROVINCIAL AND MUNICIPAL TAXES FOR THE WORK IN THE TENDER PRICE. ALL ELECTRICAL MATERIAL AND/OR EQUIPMENT SUPPLIED BY ANY CONTRACTOR OR SUBCONTRACTOR FOR INSTALLATION ON THIS PROJECT MUST BEAR EVIDENCE OF CERTIFICATION BY AUTHORIZED ORGANIZATION (E.G. CSA, WARNOCK HERSEY) OR SPECIAL CERTIFICATION ACCEPTABLE TO THE CHIEF INSPECTOR OF ELECTRICAL ENERGY FOR THE PROVINCE OF BRITISH COLUMBIA. ALL ELECTRICAL EQUIPMENT MOUNTED OR CONNECTED SHALL BE IDENTIFIED BY MEANS OF BLACK LAMACOID LABELS C/W MINIMUM 3/8" WHITE LETTERING. CLEAN ALL EQUIPMENT DURING CONSTRUCTION AND THOROUGHLY CLEAN ON COMPLETION OF THE CONTRACT. REMOVE ALL SURPLUS MATERIALS, CUTTINGS, PACKAGING AND DEBRIS FROM THE SITE DURING THE PROGRESS AND AT FINAL COMPLETION OF THE WORK. THE OWNER RESERVES THE RIGHT OF TRIAL OR TEMPORARY USAGE PRIOR TO ACCEPTING THE INSTALLATION. EXECUTE ALL WORK IN A PROFESSIONAL, WORKMANLIKE MANNER, TO PRESENT A NEAT MECHANICAL APPEARANCE. ONLY QUALIFIED WORKMEN SHALL BE EMPLOYED ON THIS CONTRACT. SUPERVISION SHALL BE BY JOURNEYMEN ELECTRICIANS AND WORK CARRIED OUT BY JOURNEYMEN AND/OR REGISTERED APPRENTICES ONLY. CO-ORDINATE WITH ALL OTHER TRADES AND ARRANGE EQUIPMENT IN PROPER RELATION WITH OTHER APPARATUS, DUCTS, PIPES, ETC., AND WITH BUILDING CONSTRUCTION ARCHITECTURAL FINISHES, AND DECOR. SUPPLY AND INSTALL ALL DRILLING, CORE DRILLING, WEATHERPROOFING, SEALING, SETTING OF INSERTS FIXTURE BACKING, PANEL AND DISTRIBUTION BACKBOARDS. CO-ORDINATE ALL CUTTING, PATCHING, EXCAVATION, BACKFILLING AND CONCRETE FOR THE CARRYING OUT OF THE WORK. INCLUDE ALL COSTS IN TENDER PRICE. ANY ELECTRICAL AND COMMUNICATION WORK CARRIED OUT ON BEHALF OF, OR BY, OTHER CONTRACTORS SHALL BE IN ACCORDANCE WITH THE REGULATIONS OF THE CANADIAN ELECTRICAL CODE AND THE APPLICABLE CLAUSES OF THIS SPECIFICATION. IT SHALL BE THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT ALL SUBCONTRACTORS AND SUPPLIERS OF ELECTRICAL EQUIPMENT OBSERVE THE APPLICABLE CLAUSES OF THE ELECTRICAL SPECIFICATIONS. IN CASE OF DIFFERENCES BETWEEN CONTRACTORS REGARDING EXTENT OF WORK RESPONSIBILITIES, SUCH MATTERS SHALL BE REFERRED TO THE CONSULTANT. SHOULD ANY DISCREPANCY BETWEEN THE SPECIFICATION AND DRAWINGS LEAVE THE CONTRACTOR IN DOUBT AS TO THE TRUE INTENT AND MEANING, A RULING SHALL BE OBTAINED FROM THE CONSULTANT BEFORE THE TENDER IS SUBMITTED. IF THIS IS NOT DONE IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE MORE EXPENSIVE ALTERNATE HAS BEEN INCLUDED..26 ALTERNATES WILL NOT BE ACCEPTED, NEW DEVICES SHALL BE OF SAME MANUFACTURER AS EXISTING SYSTEMS. CONTRACTOR SHALL SUBMIT TO CONSULTANT FOR REVIEW AND APPROVAL A DETAILED BREAKDOWN OF MATERIAL AND LABOR COSTS TO PERMIT A REVIEW OF PROGRESS CLAIM SUBMISSIONS IN ACCORDANCE WITH PROVINCIAL LIEN LEGISLATION. FAILURE TO SUBMIT THIS BREAKDOWN WILL AFFECT THE REVIEW PROCESS AND MAY DELAY PAYMENT. THE CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIAL COVERED IN THIS CONTRACT FOR A PERIOD OF ONE YEAR FROM THE DATE OF SUBSTANTIAL PERFORMANCE OF THE CONTRACT. THIS IS IN ADDITION TO ANY MANUFACTURER'S WARRANTY PROVIDED FOR SUPPLY OF MATERIALS AND EQUIPMENT. ALL WIRING SHALL BE COPPER, MINIMUM #12, LOOMEX WILL NOT BE PERMITTED. 2.0 .01 .02 .03 .04 .05 .06 .07 .08 .09 .10 .11 .12 3.0 .01 .02 .03 .04 .05 4.0 .01 .02 .03 .04 .06 RENOVATION AREA SPECIFICATIONS CONTRACTOR IS TO ENSURE THAT A MINIMUM OF DISRUPTION OCCURS TO THE OWNERS PRIMARY BUSINESS DURING THEIR NORMAL HOURS OF OPERATION. THIS MAY INVOLVE THE CONTRACTORS WORK BEING PERFORMED ON EVENINGS, WEEKENDS, AND/OR HOLIDAYS. THE CONTRACTOR SHALL INCLUDE ALL COSTS OF THIS PROVISION IN THEIR BASE TENDER QUOTE. NO ALLOWANCE WILL BE SUBSEQUENTLY BE MADE FOR FAILURE TO INCLUDE THESE COSTS IN BASE TENDER QUOTE. CONTRACTOR SHALL REWIRE, EXTEND WIRES, CONDUITS, ETC. OR INSTALL NEW FOR ANY RELOCATED ELECTRICAL DEVICES AS SHOWN ON THE DRAWINGS AND/OR AS REQUIRED. ALL ELECTRICAL DEVICES SHOWN ON THE DRAWINGS AND/OR AS REQUIRED SHALL BE NEW UNLESS OTHERWISE NOTED. ALL MODIFIED/NEW ELECTRICAL SYSTEMS SHALL BE FULLY OPERATIONAL AFTER RENOVATION IS COMPLETE AND BE ACCEPTED BY THE CONSULTANT AND OWNER. ALL REMOVED AND UNUSED ELECTRICAL DEVICES FROM THE RENOVATED AREAS SHALL BE TURNED OVER TO OWNER UNLESS OTHERWISE NOTED. INTERM STORAGE LOCATION OF THESE DEVICES SHALL BE COORDINATED WITH THE OWNER AND STORED SECURELY TO PREVENT DAMAGE. CONTRACTOR SHALL RELOCATE, REWIRE, OR REROUTE ALL WIRING WHICH PASSES THROUGH RENOVATED AREAS TO ENSURE PROPER OPERATION OF ALL ELECTRICAL SYSTEMS OUTSIDE OF RENOVATED AREAS. ANY FIXTURES, WIRING DEVICES, ETC. DAMAGED DURING AND AFTER REMOVAL SHALL BE REPLACED WITH NEW APPROVED EQUIPMENT AT CONTRACTOR'S COST. CONTRACTOR IS RESPONSIBLE FOR ADEQUATE PROTECTION OF EQUIPMENT, FURNITURE, ETC. (PLASTIC COVERS, MOVEMENT OF OWNER FURNITURE, ETC.) DURING THE EXECUTION OF THE WORK. CONTRACTOR IS RESPONSIBLE FOR CLEANING UP THE WORK AREA EACH DAY BEFORE LEAVING THE JOB SITE. ALL MATERIALS SHALL BE SUPPLIED AND INSTALLED AS SPECIFIED AND/OR SHOWN ON THE DRAWINGS. CONTRACTOR TO CONFIRM ALL LOCATIONS OF EXISTING EQUIPMENT, WIRING, CIRCUIT NUMBERS, ETC. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, PATCHING AND PAINT FOR ALL AREAS AFFECTED BY THE RENOVATION. FINAL FINISHES SHALL MATCH EXISTING AND IS SUBJECT TO FINAL APPROVAL BY THE CITY. SHOULD THE CITY ASSESS THAT THE COLORS OR FINISHES DO NOT MATCH, THE CONTRACTOR WILL BE REQUIRED TO PAINT ENTIRE WALL AND/OR CEILING. FIRESTOPPING ALL ELECTRICAL WIRES, CABLES, NONCOMBUSTIBLE RACEWAYS, OUTLET BOXES AND OTHER SIMILAR SERVICES THAT PENETRATE FIREWALL, FIRE SEPARATION OR ASSEMBLY REQUIRED TO HAVE A FIRE RESISTANCE RATING OR FIRE SEPARATION, SHALL BE SEALED BY FIRE STOP SYSTEM WHICH HAS AN "F" AND/OR "FT" RATING NOT LESS THAN REQUIRED FIRE PROTECTION RATING OF FIRE SEPARATION. "F" AND "FT" RATINGS SHALL BE DETERMINED BY FIRE TEST METHOD AS DETAILED IN CAN 4-S115-M "STANDARD METHOD OF FIRE TESTS OF FIRE STOP SYSTEMS". REFER TO RELEVANT SECTIONS OF THE NATIONAL BUILDING CODE. CONTRACTOR SHALL ONLY USE LISTED MATERIALS AND METHODS AS LISTED AND INDICATED IN ULC LIST OF EQUIPMENT AND MATERIALS, VOLUME 2, BUILDING CONSTRUCTION" (NO. 40U18 FIRE SEPARATION). SERVICE PENETRATION AND FIRE STOPPING OF SERVICE PENETRATION IN FIRE SEPARATION AND FIRE RATED ASSEMBLIES SHALL COMPLY WITH RELEVANT SECTIONS OF THE NATIONAL BUILDING CODE. PROVIDE FIRE STOPS IN CONCEALED SPACES AS REQUIRED AS PER RELEVANT SECTIONS OF THE NATIONAL BUILDING CODE. FIRE STOPPING MATERIAL SHALL BE USED TO SEAL ANY PENETRATION OF COMPARTMENT SEPARATION IN CONCEALED SPACES. FINAL ACCEPTANCE SUBMIT TO THE CONSULTANT, PRIOR TO SUBMISSION FOR SUBSTANTIAL PERFORMANCE, TWO MARKED UP SETS OF AS-BUILT DRAWINGS AND THREE SETS OF MAINTENANCE MANUALS FOR ALL ELECTRICAL COMPONENTS USED ON THIS PROJECT. AS-BUILT DRAWINGS SHALL HAVE ELECTRICAL CONTRACTOR COMPANY NAME, ADDRESS, PHONE NUMBER, DATE AND SIGNATURE STAMPED ON DRAWINGS. AS-BUILT DRAWINGS SHALL BE CONVERTED TO AUTOCAD BY THE CONSULTANT AND SUBMITTED TO THE OWNER WITH MANUALS. DELIVER TO THE CONSULTANT CERTIFICATE OF APPROVAL AND FINAL INSPECTION FROM AUTHORITIES HAVING JURISDICTION PRIOR TO FINAL OCCUPANCY. THESE MUST BE PROVIDED THREE WORKING DAYS PRIOR TO CONSULTANT FINAL OCCUPANCY REVIEW. AFTER THE CONTRACT IS COMPLETED, FURNISH TO OWNER A WRITTEN GUARANTEE THAT FOR ONE YEAR FROM DATE OF ACCEPTANCE, ANY DEFECTS IN MATERIALS OR WORKMANSHIP WILL BE CORRECTED AT NO COST TO THE OWNER. SUBMIT COPY OF GUARANTEE TO THE CONSULTANT. AS THE CONSULTANT IS REQUIRED TO GIVE PROFESSIONAL ASSURANCE THAT ALL ELECTRICAL SYSTEMS HAVE BEEN INSTALLED, TESTED AND VERIFIED IN ACCORDANCE WITH THE NATIONAL BUILDING CODE AND THE CANADIAN ELECTRICAL CODE, THE CONSULTANT REQUIRES THE FOLLOWING ITEMS FROM THE CONTRACTOR PRIOR TO ISSUANCE OF "LETTER OF PROFESSIONAL ASSURANCE " FOR BUILDING OCCUPANCY: WRITTEN REPORTS OF SITE REVIEWS BY AUTHORITIES. LETTER OF ASSURANCE OF PROFESSIONAL FIELD REVIEW AND COMPLIANCE. FIRE ALARM VERIFICATION REPORT. ALL COSTS FOR THE ABOVE SHALL BE INCLUDED IN BASE TENDER QUOTE. 5.0 DIV. 16 EXCLUSIONS 5.01 THE FOLLOWING WORK IS EXCLUDED FROM DIV. 16 SCOPE OF WORK BUT HAS TO BE DONE TO FACILITATE THE INSTALLATION OF ELECTRICAL SYSTEMS AND/OR IS AFFECTED BY ELECTRICAL INSTALLATIONS. THIS WORK HAS TO BE PERFORMED UNDER THE DIRECTION OF OTHER RELEVANT PROFESSIONAL SUCH AS AN ARCHITECT, MECHANICAL, CIVIL, BUILDING ENVELOPE, ETC, ENGINEER. THIS WORK SHALL BE PERFORMED UNDER OTHER RELEVANT SPECIFICATION SECTIONS (OTHER THAN DIV. 16). CONTRACTOR SHALL COORDINATE DIV. 16 WORK WITH ALL OTHER RELEVANT WORK. FOR DIRECTIONS, GUIDANCE, SPECIFICATION REGARDING THIS WORK, CONTRACTOR SHALL CONTACT RELEVANT PROFESSIONALS (NOT ELECTRICAL). 5.02 NON-EXHAUSTIVE LIST OF EXCLUSIONS: .1 WATERPROOFING OF NON-ELECTRICAL COMPONENTS LIKE BUILDING ENVELOPE, WALLS, ROOF, ETC. .2 X-RAYS FOR CUTTING, CORING, PATCHING. .3 CONTROL WIRING UNLESS SPECIFIED IN THIS SECTION. .4 ALL CIVIL CONCRETE, EXCAVATION OR BACKFILL WORK INCLUDING SHORING AND BEDDING. .5 COVERS FOR PULL PITS. .6 PRECAST AND/OR CAST IN PLACE CONCRETE PRODUCTS SUCH AS PULLBOXES, LIGHT POLE BASES, TRANSFORMER CONCRETE PADS, ETC. .7 DUCT DRAINAGE AND ASSOCIATED BACKWATER VALVES. .8 BACKING. .9 PAINTING UNLESS SPECIFIED IN THIS SECTION. .10 FIRE RATED DRYWALL ENCLOSURES FOR PANELBOARD AND LIGHT FIXTURES. .11 CUTTING, PATCHING OR CORING. .12 TEMPORARY LIGHTING UNLESS SPECIFICALLY DETAILED AS PART OF DIV. 16 WORK. ISSUES NO. DATE # YY/MM/DD ISSUE 1 10/07/16 ISSUED FOR PERMIT ONLY 2 10/08/13 ISSUED FOR TENDER DESCRIPTION REVISIONS NO. DATE # YY/MM/DD REVISION DESCRIPTION Sheet Information Date Job Number Drawn 6757 JL Checked RM Approved RM Title SPECIFICATIONS Sheet E103 QUEEN'S PARK - NEW WESTMINSTER, BC Meeting Location 0 Canada Games Pool & Centennial Community Centre 50 100 Meters Total Walk Route: 2.5 km NO LEFT TURN off McBride northbound M cB RIDE BLVD Park Entrance Millenni um Air Cadets il t t ul lo To Bridge y Ro Tra To P a Ho #4 ue en Softball Diamonds Vagabond Players Theatre Av #5 ARENEX al Parking Lot ial nn e t Cen odge L East Field Tennis Courts lly T Rose Garden South Field bed Greenhouse Complex Baseball Diamond Parking Lot STADIUM Picnic Shelter #2 FIRST ST Sports Field Granville To Pattullo Bridge Baseball Diamond #2 Vancouver Carpet Parks Maintenance Yard 4th Ave ROYAL AVE Washrooms Concession/ Washrooms #1 Baseball Diamond ARENA Off-leash Area Parking Lot 3rd Ave Picnic Shelter Petting Farm trance ng ki r a Spray Park ll he Playground s nd Ba k En Par P Tennis Courts Playground Right Turn Only il SIXTH AVE ra #3 ONE WAY