Medi-Gas check catalogue
Transcription
Medi-Gas check catalogue
Medi-Gas Check Range Your one stop shop for medical pipeline testing Medical gas detection for safety and peace of mind www.bedfont.com ow on 01622 851122 or email ask@bedfont.com 1 2 For more information on this product call us no Contents Page Introduction3 The G series monitors 4-5 Moisture and Impurity detection 6 Particulate Matter and Sampling Kits 6 F3004 anaylzers7 Colourmetric Detector Tubes8 MEC range9 Vacuum gauge10 Calibration gas and ‘Also Available’ 10 Medigas Qube11 Gas detection tables and corresponding products12-13 ow on 01622 851122 or email ask@bedfont.com 3 Medical Gas Pipeline Guidance (HTM02 01) In 2006 the UK government produced new guidelines in the form of the Health Technical Memorandum (HTM) 02–01. This guidance details the operation, management and maintenance of medical gas pipeline systems (MGPS) in hospitals. This provides a manual for all Quality Control Pharmacists and Appointed Persons to work from. The guidelines have placed more emphasis on the verification and validation of the piped gases to ensure the quality of the gas delivered to the patient. This includes both monitoring of the plant room and service distribution points as well as at point of delivery to patients. More information on verification and validation as detailed in HTM 02-01 is available at www.bedfont.com To aid in this Bedfont has created a “one-stop-shop” for both fixed and portable gas detection monitors and their associated accessories for all applications required by HTM 02-01, including the measurement of: •Oxygen (O2) •Nitrous Oxide (N2O) •Moisture (H2O) •Oil Content •Particulate Matter •Carbon Monoxide (CO) •Carbon Dioxide (CO2) •Oxides of Nitrogen (NOx) •Sulphur Dioxide (SO2) 4 For more information on this product call us no Medi-Gas Check G210 - N2O, O2, CO2, CO The G210 has been specifically designed for the accurate measurement of N2O, O2, CO and CO2 in one easy to use hand-held monitor. The G210 offers the user a quick verification of gas quality on an easy to read digital screen, with the additional option of being able to enter specific identification numbers for certain monitoring points around the hospital. The G210 has the added benefit of being able to identify contaminants in the piped gas. Complete with data storage and alarms this monitor is ideal for many of your MGPS verification and testing requirements. This product measures %N2O, %O2, ppm CO and CO2, is an easy to use monitor with simple calibration, and has quick verification of gas quality and impurities Order codes: G210-CO G210-CO-CAL G210 Portable N20, 02, CO2 & CO Analyser G210 Calibration & Test Kit MEDI-REG-KIT pressure regulator kit for G210 for HTM02 standards G1.16 pressure regulator kit for G210 universal (no probes) Medi-Gas Check G200 - N2O The G200 is a low level N2O atmosphesic measurement device. This portable monitor not only acts as a personal alarm, but will also calculate the time weighted average (TWA) of an individual’s exposure to N2O. The G200 also acts as a leak detection device and will store up to 1,000 readings to be used for graphs and data analysis. The G200 is able to provide readings from 0-1,000ppm in less than 40 seconds and 0-10,000ppm in leak detection mode, safeguarding both health professionals and patients. This product is ideal for: dental departments, anaesthetic departments, hospital theatres, aswell as recovery, veterinary and X-ray departments. Order codes: G200 G200 G200/10-CASE G200-CAL PACK (full kit, including monitor, calibration kit, data, case, spare CO2 filters, spare moisture filters) (Background N2O monitor) (Carry case) (Calibration Kit) G200/10-DATA (Software kit for G200) ow on 01622 851122 or email ask@bedfont.com 5 Medi-Gas Check G150 - CO2 0 - 20,000 ppm Specifically designed to monitor CO2 with a range of 0-20,000 ppm, the G150 is ideal for all indoor air quality applications. This unit has been developed to incorporate the latest technology and specification requirements, that provide the user with a fast simple to use and accurate piece of environmental field kit. Order codes: G150 G150-O2 G150-O2-RH Portable monitor for 0-10,000ppm CO2 Portable monitor for 0-10,000ppm CO2 with O2 cell fitted Portable monitor for 0-10,000ppm CO2 with O2 cell fitted and Relative Humidity Medi-Gas Check G110 - CO2 0 - 100 percentage Specifically designed to monitor CO2 in a 0-100 percent range for all indoor air quality applications, this unit has been developed to provide the user with a CO2 analyser which monitors multiple applications, including hospital pipeline gases. Key features include, quick verification of CO2 levels, built in gas moisture removal and improved accuracy on CO2 readings. Order codes: G110 Portable CO2 0-100% Monitor G110-O2 Portable CO2 0-100% & O2 0-100% Monitor G110-O2-RH Portable CO2 0-100%, O2 0-100% & Relative Humidity Monitor Medi-Gas Check G100 - CO2 and more The G100 is an easy-to-use, handheld CO2 analyser with increased accuracy in the 0-20 percent range and a bright, easy to read display. Readings are stable thanks to inbuilt moisture removal. Timesaving twin-probes check incubator top and bottom temperatures and difference simultaneously. Additionally, the increased memory holds 1000 readings. Options include O2 and/or RH analysis, temperature probes, data logging, and USB-link software to download, analyse and export data. Order codes: G100 Portable monitor for 0-20% CO2 G100-O2 Portable monitor for 0-20% CO2 with O2 cell fitted G100-O2-RH Portable monitor for 0-20% CO2 with O2 cell fitted and Relative Humidity 6 For more information on this product call us no Moisture (H2O) and Impurity Detection Measuring moisture or dew point is intended to identify contamination of the pipeline system by water1. Bedfont provides a range of portable dew-point monitoring and impurity detection devices ensuring quality at the point of drying and patient administration. The HTM 02-01 stipulates that an electronic dew-point meter should be used in preference to water content measurements2. Medi-Gas Check MDM300 portable dewpoint detection The MDM300 is a portable, high-speed dew-point hygrometer, ideal for fast, accurate and repeatable testing on the move. The unit is able to offer more tests per working hour than any other monitor on the market, with the added benefit of being able to transmit data through Bluetooth. The MDM300 is ideal for all your portable dew point monitoring. Order Code: MDM-300 Particulate Matter (PMS-1) Particulate contamination can occur as a result of building materials, dust and any foreign bodies entering when installing a new pipeline system or repairing/ maintaining old systems. Also older systems may exhibit particles due to disruption of the system, such as reverse gas flow, pressure waves or vibration. The presence of such particles can adversely affect the quality of the delivered gases. Therefore, tests to confirm their absence are important4. This test can be carried out using Bedfont’s Particulate Matter Sampler (PMS) and specialist particulate membrane filters. Order Code: PMS1-V ow on 01622 851122 or email ask@bedfont.com 7 Pipeline Sampling Kit (MEDI-REG-KIT) As part of Bedfont’s commitment to making verification and validation of MGPS as quick and easy as possible, we supply a sampling kit for use with all our monitors, detector tubes and equipment. This kit comprises of a regulator to ensure the gas flow is passed though the monitor or detector tube at the correct flow, 5 specialist gas probes, and quick connect fittings for interchanging between gases. The HTM 02-01 stipulates that when purging and checking the identity of gases such as N2O, the gas should be discharged in a manner that minimises pollution and personnel exposure5. Therefore all Bedfont sampling kits can be provided with different lengths of exhaust tubing to fit all requirements. Order Code : MEDI-REG-KIT Medi-Gas Check F3004 (MEDIC- AIR) The F3004 sets new standards in medical air quality instrumentation. The F3004, combined with Draeger detector tubes, can establish levels of carbon monoxide, carbon dioxide, water vapour, oil, nitrous fumes, and sulphur dioxide, as well as various easily oxidized compounds via a Polytest. An inbuilt electronic sensor with digital reading measures oxygen content, recorded system pressures, and temperatures. The instrument is completely portable, Order Code- MEDIC-AIR opperating from standard AA batteries. 8 For more information on this product call us no Colourmetric Detector Tubes These cost effective detector tubes offer instant measurements of many gases and vapours. The tubes are easy to read with a sharp, clear colour change and provide accuracy without the need for calibration. They can be used for a spot check of the environment as well as for a long term average over a given period of time. Supplied in a standard box of ten tubes for all your measuring needs. Our most popular tubes include: •Carbon Dioxide •Oil Mist •Carbon Monoxide •Xylene •Formaldehyde •Nitrogen Oxides •Water vapour •Nitrogen Dioxide Gas Detected CO CO2 NOx SO2 Water Vapour Concentration 5 – 100 ppm 300 – 5000 ppm 1 – 50 ppm 1 – 15 ppm 0.05 – 1.0 mg/L Order Code DET-CO DET-CO2 DET-NOX DET-SO2 DET-H2O Other Applications Include: •Vinyl Chloride •Acetone •Ethanol •Amines •Trichloroethylene •Sulfur Dioxide •Ammonia •Hydrocarbons •Phosphine •Benzene •Hydrogen Chloride •Nitric Acid •Butadiene •Hydrogen Cyanide •Phenol •Ozone •Hydrogen Fluoride •Methyl Bromide •Chlorine •Chlorine Dioxide •Hydrogen Sulfide •Chlorine Dioxide ow on 01622 851122 or email ask@bedfont.com 9 MEC Range Medical Gas Test & Commissioning Kit • A complete competence person test kit • Comprises pressure and flow, AGSS test & commisssioning, fulll anti confusion, standard particulate & purging. Order Code: MGTC-KIT 10 For more information on this product call us no Vacuum Gauge Bedfont provides a simple and easy to use vacuum gauge to show suction is present in the vacuum system. ORDER CODE – MEDI-GAUGE Calibration kits for all our monitors can be found at www.bedfont.com/shop/medigascheck or contact us direct for a quote Calibration Gasses A majority of the monitors and instruments that Bedfont supply require calibration to maintain the credible accuracy that they provide the user with. Bedfont supplies these gasses to order, as either a seperate cannister, or as part of a calibration kit for a specific monitor. Bedfont supplies: Oxygen (O2) Nitrous Ocide (N2O) Carbon Monoxide (CO) Carbon Dioxide (CO2) Nitrogen (N2) And more upon request. Bibliography 1.Department of Health (2006) Medical Gases Health Technical Memorandum 02-01: Medical gas pipeline systems. P.133 2.Department of Health (2006) Medical Gases Health Technical Memorandum 02-01: Medical gas pipeline systems. P.131 3.Department of Health (2006) Medical Gases Health Technical Memorandum 02-01: Medical gas pipeline systems. P.134 4.Department of Health (2006) Medical Gases Health Technical Memorandum 02-01: Medical gas pipeline systems. P.132 5.Department of Health (2006) Medical Gases Health Technical Memorandum 02-01: Medical gas pipeline systems. P.138 6.Department of Health (2006) Medical Gases Health Technical Memorandum 02-01: Medical gas pipeline systems. P.136 Table 29 Quality specifications for medical gas pipeline tests ow on 01622 851122 or email ask@bedfont.com 11 Medi-Gas Qube Oil Content and Polytest The HTM 02-01 stipulates that oil content should be tested for all new medical/ surgical compressed air plants before use and on a quarterly basis for existing plants1. It is also recommended that the use of polytest tubes are used as a general test for contamination of pipelines2. Detection Concentration Order Code Oil 0.1 mg/m3 – 1.0 mg/m3 MEDI-OIL PolytestNo DiscolourationMEDI-POLY In order to do this, Bedfont has the Medi-Gas Qube for testing oil content and impurities in both O2 and air. Using a specifically designed sampling system and extremely accurate Oil Impactor, this test can be completed in just 5 minutes. ORDER CODE : MEDI-QUBE 12 For more information on this product call us no For more information on this product call us no ow 13on 01622 851122 or email ask@bedfont.com 13 20.9% O2 ± 0.5% Dental Compressed Air Carbon Dioxide (CO2) Helium (He) Oxygen (O2) Mixture - O2 <30% Oxygen (O2) From Liquid or Cylinders ≥70% He 0-100% CO2 0% Then 20.9% O2 ± 0.5% Minimum 99.5% O2 95-105% O2 Nominal value of 21-22.5% O2 20.9% O2 ± 0.5% Medical & Surgical Air Synthetic Air 50% ± 2% O2 50% ± 2% N20 50% ± 2% O2, 50% ± 2% N20 Nitrous Oxide (N20) Oxygen (O2) mixture ≥98% N20 -0.2% O2 Minimum 94% O2 Oxygen (O2) from PSA Plant/Concentrator Nitrous Oxide (N20) Purity Gas G210 G210 Servo-5200 G210 Servo-5200 Medi-Gas Check G210 Medi-Gas Check Servo-5200 Medi-Gas Check G210 Medi-Gas Check Servo-5200 Medi-Gas Check TM40 Medi-Gas Check TM40 TM40-CO2 TM40-HE Servo-5200 Servo-5200 Medi-Gas Check Servo-5200 Medi-Gas Check Servo-5200 G210 Medi-Gas Check G210 G210 Servo-5200 Medi-Gas Check Servo-5200 TM40-V G210 Medi-Gas Check G210 Medi-Gas Check TM40 TM40-V Medi-Gas Check TM40 Medi-Gas Check G210 Servo-5200 TM40-V Medi-Gas Check Servo-5200 Medi-Gas Check TM40 Medi-Gas Check G210 G210 Servo-5200 Medi-Gas Check G210 Servo-5200 Order Code Medi-Gas Check Servo-5200 Medi-Gas Check Servo-5200 Product(s) Gas Purity Concentrations and Available Bedfont Monitors now on 01622 851122 or email ask@bedfont.com 14 14 For more information on this product call us no Particulates Order Code Product(s) Vacuum PMS1-V PSM1 Particulate Matter Sampler (PMS) and Purging Kit OILMEDIPOLYQUBE TEST DET-CO DET-H2O MDM300 Medi-Gas Check G210 Detector Tube G210 Medi-Gas Check MDM300 Medi-Gas Check DP300 DP-300 DET-CO2 DET-NOX DET-SO2 Free from visible particles in a 75L sample Helium (He) Oxygen (O2) Mixture - O2 <30% Carbon Dioxide Free from visible particles in a (CO2) 75L sample Free from visible particles in a 75L sample Oxygen (O2) from liquid or cylinders MEDI-QUBE Medi-Gas Qube No Discolouration No Discolouration No Discolouration No Discolouration Free from visible particles in a 75L sample No Discolouration No Discolouration No Discolouration Polytest Synthetic Air Detector Tube Sulphur Dioxode (SO2) No Discolouration Detector Tube Oxides of Nitrogen (NOx) Free from visible particles in a 75L sample Medi-Gas Check G210 Detector Tube G210 Carbon Dioxide (CO2) Dental Compressed Air Carbon Monoxide (CO) No Discolouration Water Free from visible particles in a 75L sample MediGas Qube Oil Medical & Surgical Air Nitrous Oxide (N20) Free from visible particles in a 75L sample Nitrous Oxide Free from visible particles in a (N2O) Oxygen 75L sample (O2) Mixture Oxygen (O2) Free from visible from PSA Plant/ particles in a Concentrator 75L sample Gas Quality Specifications for Medical Gas Pipeline Tests and Availiable Bedfont Products Suction Present Medi-Gas Check Vacuum Gauge MEDIMEDI- IGAUGE GAUGE Vacuum ow on 01622 851122 or email ask@bedfont.com 15 Contact Bedfont for a free demonstration www.bedfont.com Tel:+44 (0)1622 851122 Email: ask@bedfont.com Scientific contributions to health. Bedfont Scientific Ltd Station Road, Harrietsham, Maidstone, Kent, ME17 1JA, England Tel: +44 (0)1622 851122. Fax: +44 (0)1634 673721 Email: ask@bedfont.com © Bedfont Scientific Limited 2015 Issue 4- January 2016, Part No: MKT333 Bedfont Scientific Limited reserves the right to change or update this literature without prior notice. Registered in: England and Wales. Registered No: 1289798 16 For more information on this product call us no