Nastec Pilot Pump Control Box
Transcription
Nastec Pilot Pump Control Box
pilot > we move it faster > PUMP CONTROL & PROTECTION Comprehensive Pump & Motor Protection the most compact and cost-effective solution for the full protection of a pump ENERGY SAVING, INNOVATIVE PUMP CONTROL DPI Trading www.dpitrading.co.za www.incledon.co.za pilot > we move it faster > PUMP CONTROL & PROTECTION PILOT Blue Box is an electronic device for the control of single phase and three phase motors (pumps) which provides protection against: Ÿ Over current, phase loss, excessive number of starts. The backlit LCD displays the running current and PILOT stops the pump if the maximum value set by the user is exceeded. Code Model Voltage [+/- 10%] 50/60 Hz Maximum current Weight [kg] 137991 137992 137993 137994 PILOT 112 PILOT 118 PILOT 312 PILOT 325 1 X 230 VAC 1 X 230 VAC 3 X 400 VAC 3 X 400 VAC 12 A 18 A 12 A 25 A 2 2 2,2 2,4 The maximum number of pump starts is also user selectable and PILOT Blue Box will stop the pump operation if this value is exceeded. Dry running * capacitor not included in the singlephase models (available upon request) PILOT provides a display of the power factor value (P.F. or cosø) and allows the user to set a minimum threshold value for normal operations. PILOT Blue Box will stop the pump below this value to protect against dry running. Max. environment temperature: 40°C (104 °F) Max. altitude: 2000 m IP Protection: IP55 (NEMA 4) PILOT Blue Box will make up to 5 automatic restart attempts following an alarm condition at time intervals set by the user. 180 mm 120 mm PILOT Blue Box stores in memory the number of pump starts and total running hours. The alarm history is also stored to assist with servicing. 180 mm The body is constructed entirely of aluminium, making PILOT Blue Box extremely solid and easily cooled. The IP55 protection makes it possible to install PILOT Blue Box even in humid and dusty environments. Also Available 2 x PG9 2 digital inputs, user selectable as normally open (N.O.) or normally closed (N.C.), for connection of external control switches. These contacts (volt free) allow the pump to be stopped or started by float switches, pressure switches, thermal protection, etc...... 1 output relay contact to control an external alarm (250 VAC or 30 VDC, max 5A). This user configurable as N.O. or N.C. Contacts to connect a boost capacitor to assist the starting of single phase pumps. 2 x PG21 PILOT, in combination with a VASCO inverter, will start and stop D.O.L. pumps while providing them with full protection. DISCLAIMER Whilst every care was taken in compiling this data, information and related material contained herein are subject to change without notification. All detail that this document contains are provided in good faith and therefore no representation or warranty whatsoever regarding the completeness, accuracy, “up to date”, or adequacy of, suitability, functionality, ommission, or operation is specifically disclaimed of any liability for direct, indirect or consequential loss or damage, however so arising, from the use or reliance on information herein thereafter provided. INCLEDON BLOEMFONTEIN Tel: 051 408 9200 BURGERSFORT KLERKSDORP Tel: 018 462 0009 LEPHALALE Tel: 013 231 7224 Tel: 014 763 5824 GERMISTON Tel: 011 323 0800 KATHU Tel: 053 723 2213 NELSPRUIT Tel: 013 752 3121 POLOKWANE Tel: 015 292 8660 RUSTENBURG DURBAN Tel: 017 631 4200 UPINGTON Tel: 054 332 1089 WELKOM Tel: 057 396 1131 Tel: 043 736 6022 PORT ELIZABETH Tel: 041 409 8000 Tel: 014 591 7700 SECUNDA Tel: 031 716 2200 EAST LONDON DPI TRADING (Western Cape) CAPE TOWN Tel: 021 957 5600 GEORGE Tel: 044 874 2327