tender document for the furni electrical,lan,fire alarm ,civil
Transcription
tender document for the furni electrical,lan,fire alarm ,civil
TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI LTD. AT BHAWANI MALL(SAHEED NAGAR),BHUBANESWAR TENDER DOCUMENT MANAGER IFCI Ltd HIG – 4/8, BDA COLONY, CHANDRASEKHARPUR, BHUBANESWAR – 751016. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 1 of 44 CONTENTS 1. INSTRUCTION TO BIDDERS (ITB) 2. Article – 1:- SPECIAL CONDITIONS 3 Article – 2:- SITE AND SCOPE OF WORK 4. Article – 3:- MEASUREMENT, BILLING & PAYMENT 5. Article – 4:- MISCELLANEOUS INFORMATIONS 6. GENERAL CONDITIONS OF CONTRACT 7. ANNEXURES 8. AGREEMENT 9. SPECIFICATION FOR ELECTRIFICATION 10. SPECIFICATION FOR AIR CONDITIONING 11. LIST OF APPROVED MATERIALS 12. DRAWINGS 13. BILL OF QUANTITIES TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 2 of 44 IFCI INTRODUCTION IFCI Ltd., (IFCI) is the first Development Financial Institution of India (DFI), was set up in 1948, having its Registered Office at IFCI Tower, 61 Nehru Place, New Delhi-110019 with panIndia presence across 18 key locations. IFCI is a Government of India Undertaking under the Ministry of Finance. INSTRUCTIONS TO BIDDERS (ITB) 1. Name of Work: Furnishing Work (Interior, Electrical, LAN , Fire Alarm, Civil & HVAC Works, etc. in Composite) of Regional Office, IFCI Ltd. at Bhawani Mall, Saheed Nagar, Bhubaneswar. 2. IFCI Ltd. (IFCI) invites bids by E-tender system in two bid system (Technical & Financial Bid) from experienced and reputed, contractors, agencies/firms engaged in FURNISHING WORK (INTERIOR, ELECTRICAL,LAN,FIRE ALARM,CIVIL & HVAC WORKS etc. in Composite) having a minimum experience of seven (07) year in the field, as under :1. Name of Work : FURNISHING WORK (INTERIOR, ELECTRICAL, LAN , FIRE ALARM,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI LTD. AT BHAWANI MALL,SAHEED NAGAR, BHUBANESWAR. 2. 3. 4. Tender Document Cost Earnest Money Deposit(EMD) Site Inspection 5. 6. Pre Bid Meeting Date of downloading of tender document Deposit of Cost of tender document ,EMD including in original : Rs. 2,000/- (Non Refundable) : Rs. 91,000/: On 15.12.2015 at site from 11:00 Hrs. to 17:00 Hrs. : On 16.12.2015 at 14:30 Hrs. : Upto 27.12.2015 (17:00 Hrs.) from http://ifci.etenders.in : Up to 23.12.2015 (15:00 Hrs.) at Manager IFCI Ltd., HIG – 4/8,BDA COLONY, CHANDRASEKHARPUR, BHUBANESWAR – 751016 : 28.12.2015 upto 15:00Hrs. on http://ifci.etenders.in : On 29.12.2015 at 15:00 Hrs. on http://ifci.etenders.in : On http://ifci.etenders.in and To be intimated separately to the qualified bidders. : SIXTY (60) days from the date of issue of Letter of Intent (LOI) /Award of Work. 7. 8. 9. Last date and time of submission of electronic bid Opening of Technical bid 10. Opening of Financial Bid 11. Time of completion The bids are to be submitted on line in electronic format on website http://ifci.etenders.in . Bidder may download Tender Document along with terms and conditions from IFCI website www.ifciltd.com. However, for participating in the tender, it is mandatory to download & TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 3 of 44 submit the tender from the http://ifci.etenders.in website only. The bidders are requested to submit their bids prior to last date of submission to avoid non-submission of their bids due to non-availability of/hanging of website in last moments or any reason whatsoever. Either IFCI or the E-Tendering service provider shall not be responsible for any issues such as internet connectivity or internet browser etc. The last date of submission of bids will not be extended if system is hang up in last hours or congestion. IFCI reserves the right to reject all or any tender wholly or partly without assigning any reason whatsoever. 3. Bidders who wish to participate in this tender will have to register on line http://ifci.etenders.in. To participate in online tenders, bidders will have to procure Digital Signature Certificate (Type-II or Type-III) as per information Technology Act-2000 using which they can sign their electronic bids. Bidders can procure the same from any CCA approved certifying agency etc. or they may contact IFCI E-tender service provider M/s Nextenders India (P) Ltd., Contact No.: 020-30187500 (Help Desk 09:30 AM to 05:30PM on all working days.) email : support.ifci@nextenders.com Bidders who already have a valid Digital Certificate need not to procure a new Digital Certificate. The bidders are requested to read carefully the user manual available on website http://ifci.etenders.in before initiating the process of ETendering. 4. Bidder shall submit their offer online in electronic format both for “Technical” and “Financial bid”. However, cost of tender document and Earnest Money Deposit (EMD) as prescribed, in original should be submitted physically in the office of Manager, IFCI Ltd., HIG-4/8,BDA Colony, Chandrasekharpur, Bhubaneswar- 751016 on all working days during working hours before the last date and time of submission of bid. 5. Before electronically submitting the tenders, it should be ensured that all the tender papers are digitally signed by the bidders. 6. On Line submission of bids: The online bidders will have to be digitally signed and submitted in time specified on website http://ifci.etenders.in the following manner:a) Envelope-I: Technical Bid: Scanned Copies to be uploaded (.pdf):i) The bidder will have to deposit cost of tender document Rs.2,000/-(Two Thousand Only) (non-refundable) and EMD Rs.91,000/-(Rupees Ninety One Thousand Only) in the form of Demand Draft/Pay Order (PO) drawn on any Nationalized/Schedule bank in favour of “IFCI Ltd. ” payable at Bhubaneswar before opening of “Technical Bid” in the office of Manager, IFCI Ltd., HIG4/8,BDA Colony, Chandrasekharpur, Bhubaneswar- 751016 and obtain a receipt thereof and they shall upload the receipt as proof of depositing tender document cost and EMD (scanned copies) along with technical bid. Otherwise the bid in electronic form will not be considered. ii) The technical information has to be prepared very carefully as indicated in the tender document since it will be the basis for the pre- qualification of bidders. Only relevant and to the point information/document should be uploaded. Failure to provide any required information, may lead to the rejection of the offer. Bidders must read the tender document very carefully before signing on it. Technical formats i.e. all Annexures, ,all covering letters, information such as experience details, construction equipments, details of past experience, TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 4 of 44 present commitments, upto date income tax & VAT clearance certificate for last 3 years, PAN, TIN,EPF Registration No, Service tax registration no., Audited balance sheet along with profit and loss account of last 3 years, Valid and upto date Electrical license (M.V/H.T), In case of Third party License Authorization from the original License Holder on Stamp paper duly Notarized must be submitted , Firm Registration with appropriate authorities like Registrar of company, Tax Authority etc, must have office set up with proper organizational structure in Odisha, copies of letters of intent of works awarded, completion certificates etc. shall be submitted along with technical bid except Financial Bid/ Bill of Quantities. The any other relevant supporting documents including all the pages of tender document must be signed along with date as token of acceptance of the terms & conditions of tender. b) Envelope-II: Financial Bid: BOQs (.xls):- This envelope consists of Bill of Quantities (BOQs)/schedules only must be signed along with date. The rates as given in the each BOQ shall quote in figures and the rates must be inclusive of all taxes including Service Tax in financial bid and the total prices of each BOQ shall be filled by the bidder in BOQ-1 ‘ABSTRACT”. No additional charges will be allowed to be incorporated at a later date. The BOQ-1 is the “ABSTRACT” of Total Amount for complete interior furnishing works. The evaluation of financial bid shall be on basis of total amount in BOQ-1 ‘ABSTRACT”. The bidder is required to check the prices/amount carefully before uploading BOQ. 7. Proof for submitting cost of tender document and EMD are essential with technical bid otherwise bid in electronic form will not be considered. 8. In case, no bid or single bid is received, the bid will get extended by 15 days. The exact date and time of e-tender will be displayed on the E- tendering portal http://ifci.etenders.in 9. Only one bid would be considered from one firm. 10.Opening of Technical Bids: Technical bids will be opened on 29.12.2015 at 15:00 Hrs. on http://ifci.etenders.in. by the Tender Committee. IFCI shall evaluate the technical bid to pre-qualify the bidders. 11.Opening of Financial Bids: Exact date and time shall be communicated through official E-mail address given in the bid document to the qualified bidders. 12.Validity of bids: Tender submitted by Bidders shall remain valid for acceptance for a minimum period of 90 (ninety) days from the last date of submission of Bid. 13.IFCI reserves the right to reject any or all the offers without assigning any reasons thereof. 14.Conditional bids would be summarily rejected. 15.Preference will be given to the MSE bidders, who are registered as MSE in any of the recognized body as specified by Ministry of Micro, Small & Medium Enterprises (MSME) as per the provisions of the Public Procurement Policy for MSEs Order, 2012 issued by the Ministry of Micro, Small & Medium Enterprises, Govt. of India. MSE bidders are TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 5 of 44 exempted from EMD and tender document fees provided they submit necessary certificate for benefit of exemption in fees and EMD. 16.Pre-bid Meeting: For any clarification on the Bidding Document, a pre bid meeting will be held on 16.12.2015 at 14:30 Hrs. at IFCI Ltd., HIG-4/8,BDA Colony, Chandrasekharpur, Bhubaneswar- 751016. 17. Any separately submitted discount letter on the financial price shall not be considered by IFCI and shall be a ground for disqualification. Evaluation of financial bid shall be considered only on the quoted price in the financial bid submitted by the bidders. 18. Authorization and Attestation: The bidder has to submit an authorization letter or valid Power of Attorney on behalf of company/firm for signing the document 19. Contact Person: In case of any query, you may contact any of the following officials: a) Shri S. K. Mitra, Manager at Bhubaneswar (07381255601) & Email: sk.mitra@ifciltd.com b) Shri Amit Joshi, Manager at BNew Delhi (07042505087) & Email: amit.joshi@ifciltd.com c) Shri K. S Chauhan, DGM at New Delhi (09990725653) & Email: Ks.chauhan@ifciltd.com 20. Eligibility Criteria of Intending Applicants for Pre-Qualification Tenders: Firms of repute having executed projects as mentioned below need only apply. Average annual financial turnover during the last 3 years ending 31st March 2015, should be at least Rs. 15 Lakhs. And Experience of having successfully completed similar works during the last 7 years ending 31-03-2015, should be either of the following: a) Three similar completed works costing not less than the amount equal to Rs.18.20 LAKHS. OR b) Two similar completed works costing not less the amount equal to Rs.22.75 LAKHS. OR c) One similar completed work costing not less than the amount equal to Rs.36.40 LAKHS. Similar work mean carrying out Furnishing Work ( Interior, Electrical, LAN, Fire Alarm, Civil, HVAC Work etc) in Composite reputed corporate/ PSU / Govt. agencies. The tenderer should submit completion certificate from the employer clearly indicating the nature, magnitude, date of starting and date of completion, indicating whether the works are completed within the stipulated time in respect of qualifying TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 6 of 44 works. They should provide proper documentary proof supporting their claim in respect of all the above criteria. 21. An amount of Rs. 50, 00,000/- (Rupees. Fifty Lakhs Only) as Bank solvency Certificate, issued by any Nationalized/Scheduled Bank, to be furnished by the bidder. ARTICLE - 1 1. GENERAL SPECIAL CONDITIONS Conditions of Contract shall be read in conjunction with the General Conditions of Contract, Specifications of work, drawings, and any other document forming part of contract wherever the context so requires. Notwithstanding the sub-division of the document in these separate sections and volumes, every part of each shall be deemed to be supplementary of every other part and shall be with and into the contract so far as it may be practicable to do so. Where any portion of the conditions of Contract is repugnant to or at variance with any provisions of the General Conditions of Contract, then unless different intention appears, the provision(s) of the conditions of the contract shall be deemed to over ride the provisions of General conditions of the contract only to the extent of that such repugnance or variance cannot be reconciled with the conditions of contract. Wherever it is stated anywhere in this Tender Document such and such a supply is to be effected or such and such a work is to be carried out, it shall be understood that the same shall be effected/ carried out by the Contractor at his own cost, unless a different intention is specifically stated. Materials, design and workmanship shall satisfy the applicable standards, the job specifications contained herein and codes. In the absence of any standards/specifications/Codes covering any part of the work covered in this tender document, the instructions/directions of the Project Manager will be binding on the Contractor. 2. EARNEST MONEY DEPOSIT EMD for Rs. 91,000.00 ( Rupees Ninety One Thousand only) in the form of demand draft drawn in favour of IFCI Ltd. payable at Bhubaneswar from any scheduled/ Nationalised bank and should be submitted along with the Tender. The name of work/job number should be super scribed on the envelope. EMD will not carry any interest. EMD will be refunded to unsuccessful bidders after finalization of bid. The Earnest Money Deposit submitted by the bidder will be forfeited if, a) If successful bidder fails to execute an Agreement within specified time as per intimation/request of the IFCI, b) He withdraws his tender or backs out after acceptance, c) He withdraws his tender before the expiry of validity period stipulated in the bidding document, TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 7 of 44 d) He violates any of the terms and conditions of the tender, e) He revises any of the items quoted during the validity period , f) Evidences/Documents are found to be fraudulent/non-genuine EMD of successful bidder shall be returned after completion of the work, to the entire satisfaction of the IFCI/Architect. 3. Every contractor is expected, before quoting his rates, to inspect the site of proposed works and discuss with concerned engineer Architect and/or the officers of IFCI incharge. He should also inspect the source of materials, their quality and availability. The materials must strictly comply with the relevant specifications . Samples of materials as specified shall be submitted for the approval of the Architect/IFCI, before supplying at the site. 4. COMMENCEMENT AND COMPLETION OF THE WORK 5. The successful contractor should commence work from the date of issue of Letter of Intent/Work Order and complete the entire work within SIXTY (60) Days from the date of issue of LOI. In case the work is not completed in time due to the Contractor’s failure, liquidated damages at the rate 0.5% of the contract value per week for each calendar week of delay or part thereof, subject to a maximum of 10% of the total value of contract will be recovered from the Contractor. 6. PAYMENT TERMS Payments of the work executed will be made on presentation of the bill in triplicate, subject to a minimum amount of Rs 5,00,000/- (Rupees Five Lakhs only). Five percent (5%) of the value of bill will be deducted from the bill as security deposit for any defective workmanship and it will be released after 12 months from the completion date of the work, to the entire satisfaction of the IFCI/Architect. 7. VALIDITY OF TENDER: The rates quoted by Tenderer shall be valid for Three months (90 Days) and if tender is accepted rates will be valid for the entire duration of the project. 8. Rates quoted against each item will be firm throughout the contract. 9. The contractor shall not in any case after the acceptance of a contract rate, be paid any extra charges for lead involved in transport of materials to the site of work, erection and hire of T&P, or for any other reason in case the contractor is found later on to have misjudged the materials available. All taxes including Octroi, Toll Tax or any other taxes etc., shall be payable by the contractor and any claim whatsoever in this respect shall not be entertained. 10. No alteration which had been made by the contractor in the Notice of the Tender, instructions to the contractors, the contract form, the conditions of the contract, the specifications and quantities accompanying the same shall not be accepted, if any such alterations had been made or any special conditions had been attached, the tender is liable to the rejected. 11. The right of acceptance of the tender will rest with IFCI who does not bind itself to accept the lowest tender and reserves to itself the authority to reject any or all tenders received, without assigning any reason. All tenders in whom any of the prescribed conditions TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 8 of 44 are not fulfilled or are incomplete in any respect or are conditional in nature are liable to be rejected. 12. The work shall be carried out with the directions and supervision and in stages desired by IFCI or the authorized representatives of IFCI. On acceptance of the tender, the Contractor shall intimate the name of his accredited representative to IFCI. 13. The contractor or his representative shall depute a qualified Engineer and such other office personnel as may be required for the efficient execution of works. 14. No part of the contract shall be sublet without the prior written permission of IFCI nor shall transfer be made by power of attorney – authorizing others to receive payments on behalf of the contractors or in respect of any other rights. 15. The Contractor shall have to provide all safety appliances to their workers while working at heights at his own cost and follow all regulations and all statutory provisions in force. He shall be liable to incur all the expenses in consequence thereof and IFCI shall be in no way responsible for any damages arising out of this work contract. The contractor shall indemnify IFCI for all kinds of injury or death on account of any labour engaged by the contractor as well as property of the IFCI at the site of work. All the necessary compensation in this regard shall be paid by the Contractor and IFCI shall not be liable to pay any Compensation. The contractor shall be responsible for all implications and compliances under Labour Laws and Act of Odisha State and Central Government (Including fire insurance). 16. The contractor shall be totally responsible for any damage to the building, building material and his materials ,equipment, caused due to fire, rain, flood, storm, or any other natural calamities at the site of work during construction period .Also, he should keep all materials in his custody ; IFCI is not responsible for any thefts or for safeguarding the materials. 17. All works of operations and use of materials shall be as per specifications mentioned only as per the directions of the representative of the IFCI. After breaking the distressed/ damaged structural members and cleaning the rusting of reinforcement steel,. same will be shown to the representative of the IFCI before repairing and photographs of the same if required are to be provided by the Contractor. 18. The measurement of each item executed will be verified jointly and the payment shall be made within 30 days of submission of bill . 19. The contractor shall at all times abide by the instructions ,directions given in respect of the materials, workmanship etc. 20. Statutory compliance – The Contractor shall be responsible for complying with the applicable laws/bye laws/Regulations in force from time to time .Contractor shall have to bear all statutory liabilities as applicable to his workers/personnel engaged by home for the job. Nothing will be paid extra in this regard. If IFCI pays any amount in this regard, the same amount will be deducted from the final bill of the Contractor at the time of final settlement. 21. The Contractor shall have to arrange insurance for the workers/personnel engaged by him for the job. Also he will be responsible for all the dues of the workers/personnel engaged by him including the liabilities if any towards workmen compensation or under any other law for the time being in force or which may come into force during the course of fulfilment of the TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 9 of 44 Contract. 22. The Contractor shall be required to cause the demolition of any sub – standard work in respect of materials and workmanship or both .The Contractor must abide by all instructions that may be given in this regard. Loss due to such demolition, if any ,shall be borne by the Contractor only without recourse to IFCI. 23. The contractor shall maintain a site order book” at site where all instructions by IFCI shall be recorded and the contractor shall abide by such instructions and sign the book against each such instructions after compliance thereof . 24. Liquidated damage – In case of non – completion of the work within stipulated period, the contractor would be liable to pay penalty at the rate of 0.5% of the contract value per week for each calendar week of delay or part thereof , subject to a maximum of 10% of the total value of contract. 25. The contractor will purchase a comprehensive Insurance policy providing the maximum cover equivalent to the amount of work for a period of 2 months from the date start of works. 26. The contractor will quote the rates considering the prevailing taxes and IFCI reserves the right to ask for original purchase receipt of any material brought to the site. 27. The contractor will provide analysis of rate for any item quoted if so desired by IFCI. After completion of the work all the scaffolding materials are to be dismantled and removed from the premises of IFCI. All the debris are to be removed and to be dumped in a dump yard duly approved by the Bhubaneswar Municipal Corporation or any other local body by the Contractor for which the transportation arrangement shall be made by the Contractor. All the surplus materials of the contractor are to be removed and the site is to be cleaned in all respects and to be handed over to the IFCI. No extra payment will be made in this regard to the Contractor. The final completion certificate will be issued only after such action. 28. Each page of the Tender Documents should be signed by the person or persons submitting the tender in token of his/their having acquainted himself/themselves with the Conditions of Contract, General Specifications, Special Conditions etc. as laid down. Any tender with any of the documents/counterparts not signed by the Tenderer will be rejected. 29. The contractor should note that, unless otherwise stated the tender is strictly on item rate basis and their attention is drawn to the fact that, rates for each and every item should be correct, workable and self – supporting .The quantities in the schedule of quantities approximately indicate the total extent of work but may vary to any extent and may even be omitted thus altering the aggregate value of the contract. No claim shall be entertained on this account. The contractor shall bring it to the notice of the IFCI in case of any extra items not mentioned in the schedule of quantities are required during the course of the work and shall only carry out same on written approval from the IFCI. 30. The successful tenderer must co – operate with other contractors appointed by the IFCI to precede the work smoothly with least possible delay and to the satisfaction of the IFCI’S Consultant. 31. IFCI reserves the right to terminate the contract if the contractor fails to execute the job within the specified period or fails to adhere to the schedule of the work given by the contractor TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 10 of 44 and approved by the IFCI. Mode of Payment: Payment shall be made through running Bills for actual quantity jointly measured as the work progresses. 32. The contractor shall provide suitable protection system to external windows so as to avoid damages inside the office area, entry of dust, breaking of window glass panes etc. The entire scaffolding shall be covered with cloth or curtain to avoid any accident due to fall of loose materials or debris. ARTICLE – 2 SITE AND SCOPE OF WORK 2.1 LOCATION OF SITE Site of construction is located at 1st Floor, BMC Bhawani Mall, Office Space No.4, Block 1 &2 ,Sahid Nagar, in the city of Bhubaneswar in the state of Odisha. 2.2 SITE PARTICULARS Intending Tenderer should visit the site and familiarize himself with the site conditions before submitting the tender. Non - familiarity with the site conditions will not be considered a reason for extra claims, for not carrying out the work in conformity with the drawings and specifications or for not completing the work within stipulated time. For site visit, the intending Tenderer may contact the IFCI. 2.3 APPROACHES TO SITE Contractor shall make his own arrangements for any approach road to the site of work/ site office etc., which are necessary for the execution and completion of all works without any extra cost on this account. 2.4 SCOPE OF WORK Work consists of completely executing jobs civil, interior, furnishing, air conditioning and electrification works connected with the building, drawings and BOQ. 2.5 CONVEYING MATERIALS TO VARIOUS LEVELS The entire materials required for the construction of work shall be conveyed to the respective floors/levels manually approved by the Engineer in charge, without any extra cost. Contractor should make all arrangements for manual operation of the lift with necessary precautions if available. ARTICLE - 3 MEASUREMENT, BILLING AND PAYMENT 5.1 All measurements will be based on latest edition of IS:1200 5.2 Work in general is to be executed as per drawings issued for construction. For all payment purposes, measurements will be based on the actual work executed at site. Joint TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 11 of 44 measurements will be taken by the Architect Consultant and the contractor in presence of IFCI. 5.3 Linear measurements will be in metric system corrected to the nearest two decimal places. 5.4 While computing weights, for concreting purposes, weld metal weights will not be taken into consideration. 5.5 Measurements shall be in metric system and running account bills as per schedule of rates in triplicate shall be prepared and submitted for the work done based on joint measurements. 5.6 Payment shall be settled after submission of bill made within 30 days after the certification of the bill by the Architect/ IFCI– minimum amount of interim certificate will be Rs.5,00,000/- (Rupees Five Lakhs only) 5.7 Bill is to be prepared and submitted in the prescribed format. ARTICLE -4 MISCELLANEOUS INFORMATION 5.1 PROTECTION The contractor shall protect and preserve the works from all damage and / or accidents, providing any temporary roofs, window and door coverings, boxing or other construction as required. It is assumed that the contractor has assessed this cost in quoting the rates. If he does not provide such protection then the Project Manager may direct him to do so at his own cost. This protection shall be provided for all property adjacent to the site as well as on the site. Trees, shrubs and nearby buildings shall be protected from damage during the course of the work. 5.2 INSURANCE The Contractor shall be responsible for all injury to persons, animals or things, and for all structural damage to property which may arise from the operation or neglect of himself or of any nominated sub-contractor or any employee of either, whether such injury or damage arises from carelessness, accident or any other cause whatever in any way connected with the carrying out of this contract. This clause shall be held to include inter -alia any damage to buildings, whether immediately adjacent or otherwise, and any damage to roads, streets, foot paths, bridges, or way as well as all damage caused to the buildings and works forming the subject of this contract by forest, rain, wind or other inclemency of weather. The contractor shall reinstate all damages of every sort mentioned in this clause, so as to deliver up the whole of the contract works complete and perfect in every respect and so as to make or otherwise satisfy all claims or damage to the property of third parties. The owner shall be entitled to deduct the amount of any damage, compensation, costs charges and expenses arising or arising from or in respect of, any such claims or damage from any or all sum due or become due to contractor without prejudice to the Owner’s other rights in respect thereof. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 12 of 44 Necessary workman’s compensation and Contractors All Risk Policy (CAR) policy from a nationalized Insurance Company should be taken by the contractor before starting the work as per the Labour law in force and copy of which should be submitted to Client. Tax on works contract and workers welfare fund as per Odisha State Finance Act or any other state, rules or regulations will be the liability of the contractor. 5.3 SUB-CONTRACTORS No part of the work or contract shall be sub-let to other persons unless the written authority of the Project Manager is obtained. 5.4 DRAWINGS Drawings accompanying the tender documents are indicative of the scope of work and issued for tendering purpose only. Detailed construction drawings on the basis of which actual execution of the work is to be preceded will be furnished to the contractor progressively based on the programme evolved after the award of the work. 5.5 EXTRA ITEMS Rates for the extra items, if any, shall be worked out based on rate analysis of STATE PWD / CPWD schedules. The labour rate for such calculations shall be based on the prevailing cost of each category of labour in the state. The decision of the IFCI regarding such labour rates and material costs shall be final and binding on the contractor. No extra work should be carried out without written permission and approved rate. 5.6 SAFETY & SECURITY First-aid kits must be made available at the work spot / site office of each contractor and the same shall be replenished from time to time. Contractors have to provide Fire & safety equipments along with First-aid kits at the work spot. There first - aid appliance including adequate supply of sterilized dressings and cotton wool shall be maintained in a readily accessible place. An injured person shall be given first aid and taken to a hospital without loss of time, in case where the injury necessities hospitalization. Suitable and strong scaffolds should be provide for the workmen for all work that cannot safely be done from ground . No portable ladder shall be over 8 meters in length . The width between the side rails shall not be less than 30cm ( clear) and the distance between two adjacent rings shall not be more than 30cm. When a ladder is used an extra laborer / workman shall be engaged for holding the ladder . TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 13 of 44 Workers employed on mixing and handling materials such as asphalt, cement and cement mortar or concrete and lime mortar shall be provided with protective foot wear and rubber hand gloves and tin coat for covering faces and head. Those engaged in welding works shall be provided with welder's protective eye shield and gloves. 5.7 DRAWING REVISIONS Any revision in the drawings during the construction shall be accommodated without any extra cost. GENERAL CONDITIONS OF CONTRACT 1. Downloading Bid document from the website: The Bidder may download Tender Document along with terms and conditions from IFCI website www.ifciltd.com. However, for participating in the tender, it is mandatory to download & submit the tender from the http://ifci.etenders.in website only and must keep track of download any corrigendum and/ or addendum or any change in the schedule or any other relevant information issued in respect of the subject tender by IFCI. 2. Amendment to Bid documents: At any time prior to the deadline for submission of Bids, IFCI may, for any reason, whether at its own initiative or in response to a clarification sought by any prospective bidder, modify the bidding documents by amendment / addendum/corrigendum. i) The corrigendum/amendment will be issued in website http://ifci.etenders.in only. Bidders shall be solely responsible to check the web site for the amendment issued in shape of Corrigendum and/or Addendum up to last date of submission of bid. 3. Clarification on Bids: i) To assist in the examination, evaluation and comparison of the technical bids, IFCI may, at its discretion, ask the Bidder for a clarification on its Bid. No change in price of the Bid shall be sought, offered or permitted. If required, the IFCI reserves the right to ask the bidders to submit supplementary documents to support the documents already submitted by the bidder. ii) IFCI reserves the right to conduct joint post bid discussion after opening the technical bids, for clarification on technical bid and may amend the technical bid requirements so as to bring all the bidders on to a common platform. In case of any alteration in the technical bid requirements, all the bidders shall be given equal opportunity to submit supplementary price offers for that item in which alterations have been made. The supplementary offer must indicate the amount which shall be added to or TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 14 of 44 subtracted from the original price offered for that item. Both the original and the supplementary offer shall be evaluated jointly. 4. Site Visit and Pre Bid Meeting: A pre-bid meeting shall be conducted in Bhubaneswar on the schedule date & time mentioned in tender document. The prospective bidders should visit the site prior to the schedule date of pre-bid meeting and must participate in pre-bid meeting as per the schedule. During pre-bid meeting, clarification on technical bid conditions shall be done and IFCI may amend the technical Bid requirements so as to bring all the bidders on to a common platform. Any changes in technical criteria and term & conditions resulting out of pre-bid meeting shall be published in website http://ifci.etenders.in as Addendum / Corrigendum. No further deviation from the bidders shall be accepted thereafter. Accordingly, the bidders have to submit their bid. The bidders who will not attend prebid meeting as per the schedule can submit their bid; but no deviation from such bidders shall be accepted by IFCI. 5. Evaluation and comparison of Bids: Conditional bids may be rejected by IFCI. The technical evaluation shall be made strictly on the basis of the documents submitted by the bidders in support of the eligibility, the technical and commercial response. All the required information shall be furnished strictly in prescribed schedules/Annexure only. Any information indicated other than prescribed schedules/Annexure shall not be entertained. The financial evaluation shall be made on the basis of the total price as indicated in the BOQ-1 “ABSTRACT”. IFCI is not bound to accept the lowest quoted offer. Conditions, if any, on any document enclosed with Price Bid shall not be considered. IFCI’s decision in this regard shall be final and binding. 6. Execution of Contract Agreement: Bidder is required to execute contract agreement for the said work as per the prescribed proforma to be provided by the IFCI on a non-judicial stamp paper of not less than Rs.100/-within 15 days from the issue of LOI/Award Letter. The bidder shall pay for all stamps duty and legal charges, incidental expenses, if any. 7. Time is the Essence of the Contract: Time is the essence of the contract and the Contractor shall ensure that all the obligations under the contract are completed within the agreed time schedule. The Contractor shall be solely responsible for all the delays including the delays caused by it’s vendors. In case of delay in progress of the works, IFCI reserves the right to withhold the payment, cancel the contract unilaterally or complete the work departmentally or by engaging another agency at the cost and risk of the contractor. 8. Abnormal Rates: The bidder is expected to quote rate for each subsection after careful analysis of cost involved for the performance of the completed sub-section considering all specifications and conditions of contract. In case it is noticed that the rates quoted by the bidder for TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 15 of 44 any items are unusually high or unusually low, it will be sufficient case for the rejection of the tender unless the reasonableness of the rates is convincing. For scrutiny, the analysis for such rates is to be furnished by the bidder on demand. 9. Change Orders: At any time during the execution of the contract, changes may be made in the specifications, scope of contract by given a written notice to the contractor by IFCI. IFCI may make any changes in the quality and/or quantity of the work or any part thereof that may, in his opinion, be necessary and for that purpose the IFCI shall have the power to order the Contractor to do and the Contractor shall do any of the following:i) Increase or decrease or split the quantity of work include in the contract, ii) Omit any such work, iii) Change the character, quality or kind of any such work, iv) Change the dimensions of any such work, v) Execute additional work of any kind necessary for completion of the work under the contract, and no such change shall in any way vitiate or invalidate the contract but the cost, if any, arising out of all such changes shall be taken into account in ascertaining the total amount of the contract price. Where the rate is available in the contract and the same is applicable to the additional work, in the opinion of the IFCI, the cost of the additional work shall be determined as per this available rate. But, if the rate for additional work is not available in the contract, the same shall be determined by the IFCI after taking into account the market rate and labour cost at the site for similar works and shall be final. 10. The Bidder shall arrange, at his own expense, all tools, plant and equipment hereafter referred to as (T &P) labour, &electricity/water required for execution of the work. 11.Force Majeure: Any delays in or failure of the performance of either party herein shall not constitute default hereunder or give rise to any claim for damages, if any, to the extent such delays or failure of performance is caused by occurrences such as Act of God or the public enemy; expropriation or confiscation of facilities by Government authorities, or in compliance with any order or request of any Governmental authorities or due acts of war, rebellion or sabotage or fires, floods, explosions, riots or illegal joint strikes of all the workers of all the bidders. 12. Income Tax/WCT/VAT i) Income tax, work contract tax, including surcharge if any, at the prevailing rates shall be deducted from the Bidder’s bills as per the provision of Income Tax Act/Other Acts. ii) The Bidders shall ascertain from the concerned authorities regarding the applicability of Works Contract Tax/VAT/TIN/Service Tax. Necessary deductions will be made from the bidder’s bill as applicable. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 16 of 44 13.In case of any dispute as to the mode of measurement to be adopted for any item of the work not specially covered in the tender document, the mode of measurement as per Indian standard specification No. 1200 read with the latest modifications thereof shall be followed. If the contractor carries out work in multiple shifts with the permission of the client and he will have to observe all government rules and laws and shall pay to his labour fair wages in accordance with current labour and acts. No extra payment shall be payable to him by the owner on his account till the time of completion of the total project including any extensions, which may be allowed by the owner. 14. Arbitration & Reconciliation: i) In case amicable settlement is not reached in the event of any dispute of difference arising out of the execution of the contract or the respective rights and liabilities of the parties or in relation to interpretation of any provision by the bidder in any manner touching upon the contract, such dispute or difference shall (except as to any matters, the decision of which is specifically provided for therein) be referred to the sole arbitration of the arbitrator appointed by IFCI. ii) The award of the Arbitrator shall be binding upon the parties to the dispute. iii) Subject as aforesaid, the provisions of Arbitration and Reconciliation Act 1996 (India) or statutory modifications or re enactments thereof and the rules made there under and for the time being in force shall apply to the arbitration proceedings under this clause. The venue of the arbitration shall be the place from which the contract is issued or such other place as the Arbitrator at his discretion may determine. iv) The cost of arbitration shall be borne equally by both the parties. v) The work under the Contract shall, however, continue during the arbitration proceedings and no payment due to the bidder shall be withheld on account of such proceedings. vi) Failure to comply with any of the above conditions can result in termination of the contract, forfeiture of the security deposit, penalty as may be decided by IFCI and future blacklisting of the bidder. 15. RATE OF PROGRESS If for any reason which does not entitle the contractor to an extension of time, the rate of progress of the works or any section is at any time, in the opinion of IFCI/architect, too slow to comply with the time for completion IFCI /architect shall so notify Contractor who shall thereupon take such steps as are necessary, subject to the consent of the IFCI/architect, to expedite progress so as to comply with the time frame for completion. The contractor shall not be entitled to any additional payment for taking such steps. If, as a result of any notice given by the IFCI /architect under the clause, the contractor considers that it is necessary to do any work at night or on locally recognized days of rest, he shall be entitled to seek the consent of the IFCI/architect to do so. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 17 of 44 16.CLARIFICATIONS AND INTERPRETATIONS OF DRAWINGS /DOCUMENTS Should there be any discrepancy due to incomplete description/ ambiguity of omission in the drawings and other documents weather original or supplementary during the contract , found during currency of the installation work , the contractor shall immediately on observing the same , draw the attention of the IFCI/architect whose decisions will be final and binding on the Contractor. Clarifications required or discrepancies if any, not sought by the contractor in the various drawings supplied by the architects must be obtained before execution of work failing which decisions of the IFCI/Architect shall be final and binding on the contractor. Annexure -1 (1) Defect Liability Period (not fully applicable for release of retention money) : 12 months (2) Period of final measurements valuation : 30 days (3) Date of commencement : Date of LOI/Award Letter (4) Date of completion : 60 days from date of LOI (5) Agreed liquidated damages : 0.5% of the contract value per week for each calendar week of delay or part thereof, subject to a max. of 10% of the total contract value. (6) Value of work for interim certificate : 5 lakhs (7) Period of honouring certificate : 30 days TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 18 of 44 Annexure-2 BIDDER INFORMATION Dated:______________ S. No. Particulars/Details 1. Name of the Bidders/ Firm 2. Communication Address 3. Telephone No. Office Mobile Fax E-Mail Website Authorised Person - Name Designation Mobile E-Mail ID Alternate Authorised Person - Name Designation Mobile E-Mail ID 4. 5. 6. PAN No. 7. TIN No. 8. Service Tax Registration No. 9 EPF Registration No 10 ESI No. 11 VAT No. 12 Company Registration No. 13 Valid Electrical License (M.V./H.T.) TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 19 of 44 14 Income Tax Return for last 3 years 15. Beneficiary Bank Details Bank Account No IFSC/NEFT Code Name of Bank Address of Branch 16. Particular of Tender Fee Amount (DD/PO) No. Date Name of the Bank Address of Bank 17. 18. 19. 20. Particular of Earnest Money Deposit (EMD) Amount (DD/PO) No. Date Name of the Bank Address of Bank Rs. Rs. Furnish the names with address & telephone nos. of three responsible persons who will be in a position to certify about the services/quality as well as the past performance of your organization. Whether you accept all the terms and conditions of the tender; Yes/No Whether, MSME, if yes, attached valid copy of certificate. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 20 of 44 Annexure-3 1. Details of Similar Experience: Details of similar type furnishing works executed during the last 7 years. Sl. No. 1 Name & Address of the client, Concerned Person and contact/ Mobile No 2 Name and Location of work 3 Value of Work (In lakh) Stipulated Time of Completion Actual time completion with date of start & completion Completion/ Performance Certificate enclosed ‘Yes’ or ‘No’ Any other informatio n you would like to give 4 5 6 7 8 (Fill up the above table & Enclose legible copies of the supporting documents) 2. Financial Capability: Average Annual Turn Over of the bidder in the last 3 years SL. No. 1. 2. Financial Year 2012-13 2013-14 3. 2014-15 Turnover (Rs. in lakh) Average (Fill up the above table and Enclose copy of Turn over certificates, profit/loss statement certified by any Chartered Accountant.) Date: Signature of authorized person Place: Full Name & Designation: Company’s Seal TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 21 of 44 Annexure: 4 DECLARATION (TO BE TYPED ON A LETTER HEAD OF THE COMPANY/ FIRM) Dated: ____ , 2015. Deputy General Manager IFCI Ltd HIG-4/8, BDA COLONY CHANDRASEKHARPUR BHUBANESWAR – 751016 Re: FURNISHING WORK (INTERIOR, ELECTRICAL, CIVIL, LAN, FIRE ALARM & HVAC WORKS ETC. IN COMPOSITE) OF IFCI LTD. AT BHUBANESWAR REGIONAL OFFICE Dear Sir, This is with reference to above subject that:1. We have carefully read and understood all the terms and conditions of the tender and hereby convey our acceptance to the same. 2. The information / documents furnished along with the above offer are true and authentic to the best of my knowledge and belief. We are well aware of the fact that furnishing of any false information / fabricated document would lead to rejection of our tender at any stage besides liabilities towards prosecution under appropriate law. 3. We have apprised our self fully about the job to be done during the currency of the period of agreement and also acknowledge to bear consequences to of nonperformance or deficiencies in the services on our part. 4. We have no objection, if enquiries are made about the work listed by us. 5. We have not been blacklisted by IFCI or any other organization where we have worked. Further, if any of the partners/directors of the organization /firm is blacklisted or having any criminal case against them, our bid shall not be considered. At any later point of time, if this information is found to be false, IFCI may terminate the assigned contract immediately. 6. We have not been found guilty by a court of law in India for fraud, dishonesty or moral turpitude. 7. We agree that the decision of IFCI in selection of Bidders will be final and binding to us. Date: Place: Signature of authorized person Full Name & Designation: Company’s Seal: TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 22 of 44 Annexure -5 NON DISCLOSURE UNDERTAKING (INTEGRITY PACT) (To be typed and submitted in the Letter Head of the Company/Firm of Bidder) -----------------------------------------------------------------------------------------------------------NON DISCLOSURE UNDERTAKING (INTEGRITY PACT) I/We understand that IFCI ____ is committed to Information Security Management System as per their Information Security Policy. Hence, I/We M/s____________________________________________________________ who are submitting offer for providing works/ services to IFCI ___ against Tender No. ___________________________________________________________ hereby undertake to comply with the following in line with Information Security Policy of IFCI _____, ____________ To maintain confidentiality of documents & information which shall be used during the execution of the Contract. The documents & information shall not be revealed to or shared with third party which shall not be in the business interest of IFCI (Signature, date & seal of Authorized Signatory of the bidder) Date: TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 23 of 44 AGREEMENT (Form of Agreement to be executed on Rs. 100/- Stamp paper) Agreement made on the ……… day of …..................between IFCI (hereinafter called the ‘owner’) of the one part and …......................................... (Hereinafter called the ‘contractor’) of the other part. Whereas the owner is desirous of carrying out FURNISHING WORKS (INTERIOR, ELECTRICAL,LAN,FIRE ALARM, CIVIL,& HVAC WORKS ETC IN COMPOSITE for its Regional Office. (hereinafter called ‘ the work’) at BHAWANI MALL(SAHEED NAGAR),BHUBANESWAR as per drawings and bill of quantities showing and describing the work to be done to be prepared by under the direction of M/s. SOUBHAGYA NAYAK ASSOCIATES,S 3/736,NILADRIVIHAR,C.S PUR,BHUBANESWAR – 751021.……………………(Name of Consultants). And whereas the contractor has supplied the owner with a fully priced copy of the bill of quantities (hereinafter referred to ‘the contract bills’). And whereas the contract drawings and the contract bills have been signed by on behalf of the parties here to and given to IFCI NOW IT IS HEREBY AGREED AS FOLLOWS 1. For the consideration hereinafter mentioned the contractor upon and subject to the conditions annexed shall carry out and complete the work shown upon the contract drawings and described by or referred to in the contract bills and the said conditions. 2. The owner will pay the contractor the sum of Rs.................................. (Rupees …..................................................................................................................................) sum’ as shall become payable here in under at the times and in the manner specified in the general conditions and its annexed conditions. 3. The term ‘the Architect’ in the said conditions shall mean the said …M/s.SOUBHAGYA NAYAK ASSOCIATES……………….(Name of Consultants) or in the event of his death or ceasing to be the Architect for the purpose of this contract, such other person as the owner shall nominate for the purpose, not being a person to whom the contractor shall object for reasons, considered to be sufficient by an arbitrator appointed in accordance with said conditions. Provided always that no person subsequently appointed to be the architect under this contract shall be entitled to disregard or over rule any certificate of opinions of decision of approval or instruction given or expressed by the Architect for time being. 4. The contract is an ‘item rate contract’ and the rate for each item of work is as per the rates quoted by the contractor. 5. The said conditions shall be read and construed as forming part of this Agreement, and the parties here shall respectively abide by, submit themselves to the conditions and perform TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 24 of 44 the agreements on their parts respectively in such condition contained. as WITNESS our hands this Signed by the owner In the presence of day of OWNER Witness (1) Name: Address: Witness (2) Name: Address: Signed by the said contractor CONTRACTOR In the presence of Witness (1) Name: Address: Witness (2) Name: Address: TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 25 of 44 SPECIFICATION FOR ELECTRIFICATION 1. SCOPE This covers all the Specification for the electrical installation associated with the proposed Office for IFCI at BHAWANI MALL(SAHEED NAGAR),BHUBANESWAR. The installation shall be carried out in accordance with Indian Electricity Rules, relevant statutory requirements, applicable engineering standards and specific requirement included in this booklet. 2. STANDARDS The installation and components thereon shall conform to the requirements of following specifications:NBC 2005 National Building Code IS: 732 Code of practice for Electrical wiring IS: 4064 Load break switches IS: 2516 MCCBs & ACBs IS: 2559 Air break Contactors IS: 1248 Electrical indicating instruments IS: 2705 Electrical indicating instruments IS : 4237 General requirements for switchgear IS: 3047 Code of practice for Earthing. The installation & equipment offered shall further conform to standards stipulated by supply authorities, CEIG Odisha and any other statutory bodies. Modifications if any suggested by the authorities during their inspection shall be carried out at site without any extra cost. 3. DRAWINGS Following drawings & Documents will form a part of this tender document:a. POWER LAYOUT b. LIGHTING LAYOUT c. BILL OF QUANTITES Contractor shall prepare all drawings required to be submitted to the Electrical Inspectorate / CESU /any other statutory bodies and obtain necessary approvals. 4. BILL OF QUANTITIES The quantities mentioned in the bill of quantities are for the guidance of the bidder to quote. The client/consultant do not in any way guarantee that the actual work will exactly correspond to the quantities now indicated. It shall be the contractor’s responsibility to procure only requisite quantity. The client reserves the right to add/delete any portion of the work within the project site. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 26 of 44 5. TESTING All equipment included in contractor’s scope of supply shall be tested at manufacturer’s works before delivery and necessary test certificates shall be submitted. All performance tests shall be carried out after the installation in the presence of client/consultant. 6. SPECIFIC REQUIREMENTS a. If any discrepancy found between BOQ, Specification & Drawings then details as per BOQ will be prevailing. b. Electrical contractor shall have a valid ‘M.V/H.T’ license from ELBO the Odisha state Electricity Licensing Board. c. Electrical contractor shall deploy a full time supervisor with valid supervisory license at site. d. Contractor shall work in coordination with other agencies involved in the project. e. Obtaining statutory approval from CESU/BED, BHUBANESWAR, ODISHA with necessary power sanction will be an integral part of this contract. All necessary documents including the drawings for approval shall be prepared by the contractor. The installation shall deem to have taken over by the client when:1. Entire installation is physically tested in the presence of client / consultant and results were to be satisfactory. 2. Obtaining final approval from CESU including rectification of any defects pointed out during the inspection and 3. Contractor submits set of ‘AS BUILT’ drawings covering layouts and wiring diagram for the scope of work covered. 4. Contractor submits completion certificate. The defect liability period will start once contractor has completed all formalities as above. The installation and accessories shall be guaranteed for satisfactory operation for a period 12 months from the date of commissioning. Any defects noticed during this period shall be rectified free of cost. 7. SAFETY MEASURE The following points shall be strictly complied with:1. 2. 3. 4. 5. 6. All electrically operated hand tools shall be of the double insulated type. All hand tools shall have insulated handle. Safety belt to be used when working at a height of 3mt and above from ground. Properly designed ladders/scaffolding shall be used while working at heights. RCCB/ELCB to be provided in the construction power distribution network. Welding machine shall have proper terminal box for cable termination and earthing. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 27 of 44 8. SWITCHBOARDS Type of construction Thickness of sheet steel barriers Base frame Degree of protection Height of the switchboard Maximum operating height Minimum operating height Type of doors/covers : Cubicle, Compartmentalized, totally enclosed, Floor/wall Mounting, Freestanding, Single front, Single bus, on draw-out : 2mm for body/door/equipment mounting frame and 1.6mm for : Fabricated from ISMC 75 : Dust and Vermin proof – IP 54 : Not more than 2200mm. : Not more than 1800mm : Not less than 450mm : Hinged doors with concealed hinges for switchgear Compartments & cable alleys. Bolted covers for bus bar Compartment Cable entry : Front side. Top / bottom. Paint finish : Powder coated or stoved synthetic enamel of approved colour Thickness of paint finish : Not less than 50 microns Maintenance of components : From the front side only Type of name plates : Anodized aluminum with engravings Miscellaneous : • Length of shipping section less than 2.5M • Hardware shall be high tensile zinc passivated type • Spring washers for all bus bar joints, Equipment fixing and terminals • Endless neoprene gaskets to be provided on all doors and covers • Continuous earth bus of 25x6mm copper • External Feeder identification marking to be done Safety Features: • All live parts to be totally shrouded. • Wiring shall be finger touch proof. • Bus bar to be sleeved with heat shrinkable colour coded PVC sleeves • Door interlocks for switches. • Pad locking facility for switches • Component mounted door shall be earthed • Danger board on live parts covers. Bus bar Material : Electrolytic grade AL / Copper Supports : SMC/DMC/FRP. Current density : Not more than 0.8 Amp/Sq.mm Short time rating : 25KA for 1 Sec. Clearances : 50mm clear between phases and 25mm clear between phase to neutral and phase to earth. Wiring : • Internal wiring for metering and protection shall be carried out using 660V grade PVC insulated multistrand copper conductors. For control &signalling minimum size shall be 1.5Sq.mm.For CT circuits wire size shall be 2.5 Sq.mm. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 28 of 44 • Each wire shall be terminated with tinned copper lug at Separate terminal, identified at both ends by yellow colour ferrules • Shorting links shall be provided for all CT terminals • Rubber grommets shall be provided wherever required, so that metal parts shall not come in contact with any power or control wire/cable. Inspection & Testing : • During fabrication, switchgear shall be subject to inspection by client or by any other agency authorised by the client • Once the fabrication and assembly of the switchgear is Completed supplier shall arrange for an acceptance test. • A general visual check covering dimensional checks, verification of feeders, wiring, bus bars, etc. • Manual and electrical operation of all components • High voltage test at 2.5kV. • Insulation resistance check before and after high voltage test • Supplier shall furnish a test certificate covering all the test result Feeder details : Feeder details shall be as per single line diagram and Bill of Quantities. Guarantee : The switchgear and accessories shall be guaranteed for satisfactory operation for a period 12 months from the date of commissioning. Any defects noticed during this period shall be rectified free of cost Documentation : Following drawings shall be submitted for approval and ‘AS BUILT’ drawings shall be submitted after completion of the installation. • Overall size of the switchboard along with the bid • GA arrangement of the switchboard • Single line diagram and control wiring diagram if any 9. ISOLATORS This shall be of fault making load break type and motor duty with sheet steel enclosure. Operating handle /front drive shall have door interlock. Pad locking facility to be provided for operating handle so that switch can be kept locked in the off position. All live parts shall have shrouding. Sufficient room for cable entry to be provided. 10. EARTHING a. A TNS type of earthing with separate neutral and safety earth conductor running through out to be adopted for the installation. b. Ring main conductor shall be 25x3mm Electrolytic grade copper. This ring main conductor will be laid out to interconnect all earth electrodes and various earth benches throughout in the installation. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 29 of 44 c. In outdoor area above ring main can be buried in an excavated trench. Depth of laying shall be not less than 600mm. For indoor installation conductors shall be neatly clamped to the supporting system. Suitable clamps shall be used to install the earth conductor. Direct fixing using screws/bolts not permitted. d. The material for earthing shall be electrolytic grade bare copper. The end connection shall be of bolted type with suitable crimping type terminal lugs. e. All equipment receiving three-phase connection shall have double earthing and single-phase equipment shall have single earthing. f. All cable glands shall be earthed using earth tag/ copper clamps and suitable size bare copper conductor. All non-current carrying metal parts shall be connected to the earthing system using bonding conductors. g. Earthing conductor size shall be decided based on the size of the phase conductor and this is as follows:1. Up to 16Sq.mm copper (Phase conductor) Earth conductor size shall be 16Sq.mm. 2. Above 16Sq.mm size of Earth conductor shall be half of phase conductor. 3. Suitable de-rating shall be provided when Aluminum conductor is used as phase conductor whereas copper is the earth conductor. h. Metal Conduits if any shall be earthed separately near the MCB DB. All non –current carrying metal parts shall be connected to the earthing system. i. Each load center will have an earth bench suitably located and each switch board/ DB safety earthing shall be connected to the above bench and bench in turn will get connected to the ring main conductor. j. Wherever joints or tap off are required from the ring main, that area to be properly tinned. Lap joints in the conductors shall be with 50mm of overlap. k. All earth electrodes shall be prepared as per BIS and typical drawings enclosed. This shall include 3meter long 13mm thick cast iron pipe, test link, brick masonry chamber, heavy duty cast iron chamber cover etc All hardware shall be SS only. Name plate showing earth electrode details such as name, type, earth resistance, date of maintenance etc. to be provided inside the chamber. 11. LT CABLES a. The LT power cable above 6 Sq.mm area shall be of the Aluminum conductor and lower sizes shall be of copper conductor. b. This shall be of 1.1kV grade, PVC/XLPE insulated, PVC sheathed, galvanized tape/wire armored and PVC served suitable for underground laying. c. The Aluminum conductor used shall be of electrolytic grade, 99% purity. Whereas copper TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 30 of 44 conductor shall be made out of 99.9% pure copper. d. The conductor shall be of circular/sector shaped and internal insulation of individual conductor shall be color coded. e. Cables shall be visually inspected and insulation resistance test shall be conducted before commencing the installation. f. Sharp bends and kinks shall be avoided in the installation. Bending radius shall not be less than12 times the diameter of the cable. Cable shall be laid one beside the other and not on top of each other. Adequate extra lengths shall be provided near all the terminations. g. Identification tags made out of Aluminum bearing cable number and size shall be provided at either ends of the feeder cable. h. Cable glands shall be single compression SIBG type made out of extruded brass and cadmium plated. End termination shall be of crimping type Al or Cu depending on the conductor type. Cable glands shall have earth tag and it shall be securely connected to the earthing system via earth bench. i. Strict coordination to be provided between size of cable and rating of the up stream protection device and also with the earthing conductor as specified in earthing above. 12. CABLE TRAYS & SUPPORTING STEEL Cable trays shall be ladder type fabricated out of MS channels / angles / strips etc. size of the sections shall be as per cable tray dimensions and number of cables it has to carry. However minimum thickness of the section shall be 3mm. typical details are shown in the drawing enclosed. Trays shall be painted with 1 coat of primer and 2 coats of synthetic enamel. Trays and supporting system shall be designed to withstand the total weight and without any deformation. Steel frame work duly painted shall be used for supporting switch boards DBs etc. also ISMC 100/40 may be installed across the substation/ switch room trenches as a bridge and switchboards has to be installed to it. 13. MCBs, RCCBs, & MCB DBs a. The MCBs shall be DIN rail mounting, bimetallic magnetic type. This shall have minimum fault interrupting capacity of 10kA. b. RCCBs shall be DIN rail mounting type and have a sensitivity of 30/100mA, two/four pole as specified. The tripping time shall not be more than 30ms. This shall have short circuit protection if specified. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 31 of 44 c. MCB DB shall be wall mounting type factory assembled. DB shall be dust proof with double door arrangement and suitable for concealed/surface mounting. Door shall have good quality gaskets and hinges. This shall be suitable for either TP/SP MCB outgoing (vertical) or only SP MCB outgoing (horizontal) as required. d. All circuits shall be neatly terminated to the corresponding terminals and proper dressing inside the DB shall be carried out. Circuit identification ferrules to be provided for each conductors of a circuit. e. Horizontal DB shall have three separate neutral and earth bus/terminal strip. The DB shall be supplied with suitable Copper Bus bar of 63A rating and interconnection. f. Horizontal DB shall have earth leakage circuit breaker provided at each of the 3 phases and a 4P MCB / Isolator for the main incomer. g. The DBs shall have knock out cable entry at top and bottom and earthing terminals. h. Circuit identification, feeder identification and cable size shall be suitably marked on the DB after the installation. i. Only 30mA Earth leakage circuit breakers shall be used at user level final circuits. j. Where ever cables cannot be glanded on to the DB because of specific site conditions a separate factory made cable entry box (adaptor) shall be provided. 14. CONDUITS a. Unless otherwise specified all conduits used concealed in RCC slab shall be heavy duty PVC and medium duty PVC for concealed in brick masonry work. All accessories shall be of same type compatible each other. Black color conduits are preferred for electrical services. All conduits shall have ISI mark. b. Maximum number of wires that can be drawn through a specified size of conduit is as follows:Cross sectional Area in Sq.mm 1.5 5 2.5 5 4.0 3 6.0 2 20 25 10 8 8 5 Size of Conduit in mm 32 14 12 10 8 38 c. Conductors carrying different supply voltage shall be drawn through separate conduits. d. Only bends shall be used wherever conduits take right angle deviation and no Elbows are permitted. The above bends shall be of inspection type in the critical location for the ease of TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 32 of 44 maintenance. Cut ends of conduit shall have no sharp edges or burrs to avoid insulation damage while pulling. e. Conduits used in concealed RCC slabs shall be laid on the finished centering over the reinforcement bars and tied to the bars at every 600mm. using GI tie wire. f. Where ever conduits are required to embed in walls, same shall be cut to make conduit grooves to appropriate depth using cutting machines and conduits shall be fixed by means of saddles or pipe hooks at regular intervals. Horizontal conduit grooves shall be avoided as far as possible. Contractor shall make good the conduit grooves on the wall by covering with cement mortar. Top edge of the conduit shall be at least 20mm below the finished surface of the wall. g. For surface wiring, conduits shall be fixed by heavy gauge saddles to the wall etc., with GI screws. The spacing between the fixing saddles shall not be more than one meter. However, when there are accessories/fittings, saddles shall be fixed both sides at a distance of 300mm from the center of the fitting. h. Bends shall be avoided as far as possible in the concealed conduiting and all curves should be maintained by bending the conduit itself with a long radius for easy drawing of wires. i. The entire system of conduits after the installation shall be checked for mechanical and continuity. Metal Conduit system shall permanently connected to the earth grid properly by means of suitable earth clamps. 15. WIREWAY TRUNKING a. Wire way trunking shall be fabricated out of 1.6mm thick CRCA sheet with proper jigs and fixtures to get consistent dimensional accuracy. b. This shall comprise of totally enclosed ‘C’ type channel with screwed or push fit type of front cover all hardware used shall be of good quality zinc passivated type. c. Prior to painting this shall be properly pre-treated preferably by seven-tank process and shall be powder coated with an approved shade. d. Cable clamping provision at regular intervals of not more than 500mm shall be made inside the wire way. Further 25mm dia knock out entries shall be provided at every 1000mm on top and bottom. e. This shall be installed as surface/ concealed mounting in the wall / floor. The installation rate shall include necessary floor / wall chasing and finishing after the installation of wire way. 16. WIRING a. Maximum number of wires than can be drawn through a specified size of conduit is shown above and this limit shall not be exceeded. Different circuits shall be used for Power and Lighting. & UPS. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 33 of 44 b. Each circuit shall have phase neutral and earth conductor. Looping of earth and neutral conductor between different circuits are not permitted. Size of the neutral and earth conductor shall be same as the phase conductor. Wires shall be with copper conductor, fire retardant low smoke type. Conductor shall be bright annealed and properly bunched together to form a concentric shape. c. Each circuit inside the DB shall have circuit identification marking at both ends i.e. DB side and switch box end. Neutral conductor shall be terminated to the neutral bar of that particular phase and same as the case of earth conductor. Phase conductor shall be directly connected to the corresponding MCB. d. It is highly essential to protect each circuit using appropriate capacity MCBs at DB. Following guide lines shall be ensured:1) 1.5Sq.mm Copper wiring - 6A MCB. 2) 2.5Sq.mm Copper wiring - 10A MCB 3) 4.0Sq.mm Copper wiring - 16A MCB 4) 6.0Sq.mm Copper wiring - 20A MCB 5) 10Sq.mm Copper wiring - 25A MCB e. Wiring shall be colour coded and properly ferruled with yellow colour ferrules. As far as possible looping system shall be adopted and tap off joints to be avoided. f. Circuit wiring shall mean wiring from MCBDB to switch boxes/socket outlets. Point wiring shall mean wiring from switch box to light / fan points. This shall include conduits switches, front plate, GI/coated switch boxes, 1.5Sq.mm wiring, junction boxes, drop wiring (wiring from ceiling junction box to light fixture) including earth wire, steel reinforced flexible conduit with glands for drop wiring etc. All accessories required for a good quality installation shall be included 17. SWITCHES & SOCKETS a. All switches, sockets & accessories shall be decorative modular type or as specified in the bill of quantities. Metal boxes are preferred over PVC samples are to got approval from Architect/Client before placing order. b. All sockets shall have safety shutters to prevent inadvertent contact. c. Wherever switch boxes has to be of concealed type, only metal boxes made by the same manufacturer of switches / sockets shall be used. All metal switch boxes shall be suitably earthed. The end termination shall be with crimping type copper cable lugs. d. PVC switch boxes shall be used where surface mounting option is required. e. Switchboxes shall be recess mounted in the wall. Circuit identification with suitable permanent marking shall be provided on each switch box. Required knock outs only shall be opened for conduit entry. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 34 of 44 f. Extra care shall be ensured while installation so that ‘plumb’ and ‘level’ shall be properly maintained. g. Front edge of the switchbox shall be in line with finished surface (after plastering) of the wall. h. Switch boxes shall be earthed using the earth conductor of respective circuit wiring. i. Height (from FFL) of Light switches shall be 125cms or as specified in the drawings. j. Switchboxes shall be generally located 15cms from the edge of any door/window or as per the aesthetic requirement as the case may be. k. Only one circuit shall be terminated in one switchbox. If more number of circuits are required at one location separate switchboxes shall be installed side by side. l. At least one blank space shall be provided in each switchbox. m. Switches shall be provided only on the phase conductor never on a neutral conductor. 18. INDUSTRIAL PLUG & SOCKETS a. This shall be of heavy duty type with 3 pin for single phase supply and 5 pin for three phase supply. Sockets shall have either metallic or thermo plastic enclosure complete with interlocked rotary switch of appropriate rating as required. b. Interlocking will be such a way that plug cannot be removed from the socket when switch is on closed position. This shall have instant locking with screw less clamping arrangement. c. Mechanism shall ensure earth connection shall be establish first while connecting plug to socket and while removing earth connection should break after phase and neutral. d. All terminals shall have captive screws with ¾ rotation. And unit shall be color coded to distinguish single phase and three phase supply. 19. LUMINAIRES a. Luminaire shall be free issue item by the clients. Contractor shall receive it from site store and installed as marked in the drawings. b. Surface mounting Luminaires shall be directly installed to the ceiling / wall using GI anchor fasteners c. Recess mounting luminaire shall be installed using suitable arrangements like suspension chains from ceiling slab and weight of the luminaire shall not be transferred to the false ceiling grid. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 35 of 44 d. For installation where false ceiling is provided, it is preferred to have a common supporting system for conduits and luminaires. Contractor may coordinate with interior work contractor for any such method. e. Threaded type of suspension system is preferred over steel bracket. f. Earthing of the Luminaire body using respective earth conductor of point wiring shall be ensured. g. Steel reinforced Flexible conduits with glands shall be used for drop wiring (between ceiling junction box and luminaire) for recess mounting type. 20. FANS a. All fans shall be 5 star rated. b. Ceiling fans shall be three blade totally enclosed type with capacitor start and run suitable for 240volts single phase 50Hz supply. c. This shall be of double ball bearing type 1200 / 1400 mm sweep as the case may be complete with suspension rod canopies and mounting bushes. d. Wall mounting fans shall be 450mm sweep 3 blade low noise type and with oscillating mechanism and shall comprise mounting bracket wire guard for the blades and in built regulator for speed control. e. Exhaust fans shall be 3000mm dia 900 RPM 3 blade low noise type. This shall complete with mounting ring bracket, wire guard for the blades and bird screen. 21. PREAMBLE TO BILL OF QUANTITIES a. The bidder shall carefully go through the tender documents and quote the unit price, which shall be inclusive of all installation accessories and consumables. No extra amount will be paid for any incidental, contingent work and materials. b. The quantities indicated cover the probable quantities of work involved and are for the guidance of the bidder. The order arising out of this inquiry will be an unit rate contract and not a lumpsum one .The owner, however, does not in any way guarantee that the actual work involved would correspond to the quantities indicated in the tender. c. No change in unit rate will be allowed for any change in quantity or for any other reason whatsoever. d. All measurements will be carried out in metric units. e. The rates quoted shall include all taxes, duties, packing, forwarding, freight and unloading charges. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 36 of 44 f. The installation charges shall be inclusive of the cost of shifting materials from the Stores, unpacking, installation on foundations as specified elsewhere, supply of hardware, consumables and any minor Civil works involved. g. The installation rate for cables shall include shifting of cable drums, unwinding and laying as per engineering standards all labor supervision, routine testing, consumables such as identification tags, clamps etc. However, the cost shall exclude steel supports, installation of trays and cable termination. h. The supply rate quoted for cable termination shall include single compression brass cable gland, crimping type lugs earth tag for gland earthing. The installation rate shall include all consumables and labor. i. The installation rate of all switchboards shall exclude the cost of cable termination, but shall include the cost of shifting, leveling, grouting with necessary hardware and consumables and conducting all pre commissioning tests as per statute / Specified above. j. Installation rate for all switch board, DBs & switch box shall include proper neat legible feeder identification marking and circuit identification. k. The installation rate of wiring shall include the cost of all necessary hardware and consumables required for fixing the conduits / conduit accessories, drawing, P.V.C insulated copper wires and end termination. l. The rate for installation of earthing conductors shall include drilling holes for equipment terminations, cost of lugs for earthing wires, suitable fixing clamps and SS hardware. m. All testing charges for the Equipment shall be including in the installation rate of the respective equipment. n. The cost of steel framework, supporting the structure, etc. required for the Switchboards shall not be include in the installation price. The same shall be separately quoted under the Head Supply and installation of supporting steel SPECIFICATION AND CONDITIONS FOR AIR CONDITIONING 1. CONDITIONS IN CONJUNCTION WITH OTHER DOCUMENTS Conditions of contract shall be read in conjunction with the Technical specifications, Drawings, schedule of quantities and other documents forming part of this contract wherever the context so requires. 2. MAKE AND OTHER DETAILS OF MATERIALS The contractor shall furnish a list of makes selected from the list of approved makes indicated in the tender as well as other details of various materials he proposes to use on the work and this would be subject to the approval of the Consultant/IFCI. 3. SHOP DRAWING The Contractor shall submit to the Consultant detailed dimensioned shop drawings covering all items of ducting and diffusers, piping and valves, AHU location ,plant room, electrical layouts TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 37 of 44 etc. No fabrication and installation should be put into execution until these shop drawings are approved by Consultant. The Contractor shall submit in duplicate the shop drawings prepared by him for checking and variation by the consultant. The Contractor shall then submit in duplicate corrected shop drawings for final approval. 4. TESTING The Contractor shall solely be responsible for the testing and commissioning of those works covered by this specification in compliance with standard procedure. 5. SITE WORK CO-ORDINATION The Contractor should co-ordinate with all the others works being carried out at the site so that conflicts are foreseen in advance. The work program at the site should be prepared in advance and planned based on the completion date mentioned. If any information / work front / drawings are not available at the time of carrying out the work, these are to be informed to the Owner / Consultant immediately. 6. PROJECT DESCRIPTION Condensing Units and Air Handling Units has been designed to provide thermal environmental control for Proposed IFCI. The designated air-conditioned space with comfort cooling so as to maintain inside conditions of Dry Bulb Temperature (DBT) of 24 ± 1 ° C, and not more than 60% Relative Humidity. 7. SYSTEM DESCRIPTION The air conditioned areas and their respective tonnages is given in the Basis of Design. Thermally insulated supply air ducts shall be installed in the ceiling spaces. Conditioned air shall be directly discharged through supply air grilles/diffusers. SPLIT UNITS 1. CABINET The split units/Packaged units shall have metal cabinet of 1.6mm thick (16 Gauge) galvanized sheet steel. The body should be machine pressed and adequately stiffened. The body should be chemically treated for corrosion resistance and epoxy powder coated. The evaporator unit shall be ceiling suspended. 2. COMPRESSOR All compressors shall be hermetically sealed scroll type of suitable capacities. Compressor shall be suitable for freon refrigerant. The compressor shall be electrically interlocked with indoor and outdoor fan motors, HP/LP cutouts and thermostat in the evaporator. 3. CONDENSER (AIR COOLED) The coils shall be made of copper hydraulically bonded with aluminium fins. The tubes shall have a minimum of 9.5mm outer diameter, firmly bonded with aluminium fins spaced at 12-14 fins / inch. The air velocity across the face of the coil shall not exceed 200 m/min. The coils TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 38 of 44 shall be designed for a maximum working pressure of 35 kg / sq. cm. The condensor coil shall be protected on the open end by a wire mesh duly powder coated / plastic coated. 4. EVAPORATOR COIL The coils shall be made of copper hydraulically bonded with aluminium fins. The coils shall be hydrophilic in nature. The tubes shall have a minimum of 9.5mm outer diameter, firmly bonded withaluminium fins spaced at 12-14 fins / inch. The air velocity across the face of the coil shall not exceed 170 m/min. The coils shall be designed for a maximum working pressure of 35 kg / sq. cm. The circuit should include a thermostatic expansion valve/capillary tube, distributor, liquid strainer, suction line shut off valve and liquid line shut off valve. 5. CONDENSOR MOTOR The condensor motor shall be of IP –55 rating. 6. REFRIGERATION PIPING AND ACCESSORIES Only hard drawn copper shall be used in piping with brass fittings wherever required. Brazing shall be with silver copper phosphorous alloy. Horizontal lines shall have a grading of at least 1:250 away from the compressor and towards condenser to prevent gravity draining of oil to compressor.Liquid lines shall be sized to ensure that flashing of liquid refrigerant does not occur. The circuit shouldinclude a thermostatic expansion valve, distributors, liquid strainer, dehydrator and liquid lines shut offvalve and suction line shut off valve. Leaks shall be tested with soap solution at a minimum pressure of 21 kg / sq. cm. After all leaks have been repaired, system shall be tested with the test pressure maintained for a period of not less than 8 hours. No measurable drop in pressure should be detected after the pressure readings are adjusted for temperature changes. After satisfactory completion of the pressure test, the system shall be evacuated to reduce the pressure to 0.1 Kg/Sq.cm. for a period of 6 hours and vacuum broken. A vacuum pump connected to the refrigeration system shall be used to create the vacuum and the installed compressor shall not be used to create the purpose. The system shall again be evacuated and a vacuum of 0.01 Kg/Sq.cm. maintain for 24 hours before charging with correct quantity of refrigerant and oil. The system shall be operated for 12 hours and then again tested for leaks. 7. DRAIN PIPING Drain pipe shall be of 32mm dia. PVC pipes. All evaporator units shall be provided with independent drain lines with suitable U traps. The drain shall be taken to the nearest exit points. 8. FAN Fan section including wheel and housing shall be of heavy gauge steel / aluminium. Fans shall be centrifugal, forward curved multi-blade type. Fan housing shall have inlets and guide vanes for smooth air flow. Fans shall be complete with drive motor .The fans should be statically and dynamically balanced. The fan motor should be resilient mounted. The fan should deliver a static pressure of 20mm. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 39 of 44 9. DAMPERS All fresh air intakes shall be provided with dampers. The fan outlets should be controllable with a damper. The supply collars, wherever mentioned, shall be provided with collar dampers. 10. FILTERS All evaporator units shall be provided with air filters capable of filtration unto 20 microns. The filters shall be of washable synthetic fiber type. 11. CONTROL PANEL All units shall have independent electrical control panels housing contactors, overload relays, Voltage cutouts, time delays, interlocks, strip connectors, indication lamps, and control fuse. The control Panel shall be housed inside a cabinet which shall be fixed at a convenient spot on the plywood boxing. 12. THERMOSTAT The thermostat shall be control wired with the control panel and shall be placed in the return air path inside the boxing. 13. INSTALLATION Adequate vibration isolation using rubber / neoprene pads / vibration springs in order to reduce transmission of vibrations to the floor shall be provided for all condensing units. 14. TESTING Split units after installation shall be tested for its conformity to specifications. Units shall also be tested for the rated capacity and power consumption. TEST RESULTS The following readings shall be recorded hourly during the tests and capacity of the plant shall be computed. A. Compressor 1. Suction pressure - Kg/Cm2 (psi) 2. Discharge Pressure - Kg/Cm2 (psi) 3. Rated capacity - HP 4. Rated Volts - Volts 5. Rated current - Amps 6.Power Consumption at - KWHr .B Condenser 1. Refrigerant condensing pressure - Kg/cm2 (psi) TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 40 of 44 2. Refrigerant condensing Tempr. - C (F) 3. Entering air tempr. - C (F) 4. Leaving air tempr. - C (F) 5. Pressure drop through condenser - Kg/cm2 (psi) C Motor 1. Rated Horse Power - HP 2. Rated Volts - Volts 3. Rated Current - Amps 4. Actual current - Amps 5. Actual Volts - Volts 6. Starting current - Amps 7. Power factor D.Supply Air Grilles 1. Area of Grill - m2 (Sft) 2. Velocity - M/S (FPM) 3. Air flow rate - M3/Hr 4. Temperature DB - C (F) 5. Temperature WB - C (F) E. Filters 1. Total area - m2 (Sft) 2. Effective area - m2 (Sft) 3. Velocity of air - M/S (CFM) The observations of the test shall be recorded for each item separately. Scope of Work Supply of the equipments. Design of air conditioner Erection of equipment Armaflex insulation for refrigerant piping Erection of Evaporator Unit & Condenser Unit. Electrical Cabling connecting Evaporator unit and Condenser Unit. Refrigerant Piping with insulation Condenser unit Stand. Electrical cabling between indoor unit and outdoor unit.. Drain piping to take out condensate water in the evaporator unit. Leak Testing. Vaccumisation. R-410 Gas Charging. Testing & commissioning of the Air-conditioning system. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 41 of 44 LIST OF APPROVED BRAND NAMES All material specified in the schedule of quantities, specifications and conditions of contract must conform to the following brand names , be factory made and be of first quality, BIS /IS marked wherever available. Fabricated items shall be manufactured in accordance with the CPWD / ISI specifications and be first quality. Samples of all materials to be used must be submitted and got approved before actual procurement and IFCI / Architect reserves the right to select any of the brand names specified herein for use. S.No: MATERIAL DESCRIPTION BRAND / TRADE NAME OR EQUIVALENT APPROVED BY ARCHITECT /IFCI. 3 Locks ASIAN, ICI, BERGER, JOTUN OR EQUIVALENT APPROVED BY ENGINEER IN CHARGE/IFCI. APEX, WEATHER PROOF PAINT OR EQUIVALENT APPROVED BY ENGINEER IN CHARGE/IFCI. GODREJ, DORMA ,CIEF,ACME OR ANY OTHER APPROVED BY ARCHITECT/IFCI. 4 Venetian/Vertical/Roller Blinds VISTA , HUNTER DOUGLAS, MAC ,AEROLEX OR ANY OTHER APPROVED BY ARCHITECT/IFCI. 5 VITRIFIED/Ceramic tiles 6 White Cement 1 Paints Water 2 proof paint 7 FALSE CEILING BOARD 8 Steel Reinforcement Bars 9 Structural steel sections 10 FLOOR SPRING 11 AUTO CLOSING HINGES 12 CHAIRS/SOFA 13 14 15 KAJARIA, SOMANY,RAK OR ANY OTHER APPROVED BY ARCHITECT/IFCI. BIRLA, J.K OR EQUIVALENT APPROVED BY ENGINEER IN CHARGE/IFCI. INDIA GYPSUM,LAFARGE,ARMSTRONG OR ANY OTHER APPROVED BY ARCHITECT/IFCI. KAIRALI, VIZAG, METCON (ISI TMT)OR EQUIVALENT APPROVED BY ENGINEER IN CHARGE/IFCI. TISCO, SAIL OR EQUIVALENT APPROVED BY ENGINEER IN CHARGE/IFCI. DORMA,GODREJ,EVERITE OR ANY OTHER APPROVED BY ARCHITECT/IFCI. GODREJ,EBCO,HETTICH OR ANY OTHER APPROVED BY ARCHITECT/IFCI. GODREJ/DICE/STELLAR OR EQUIVALENT APPROVED BY ARCHITECT /IFCI. INDIAN PLYWOOD MFG.LTD, NATIONAL PLYWOOD, DURO, GREENPLY OR EQUIVALENT APPROVED BY Water Proof Shuttering Plywood ENGINEER IN CHARGE/IFCI. 1ST CLASS BURMA TEAK OR GHANA TEAK , KERALA TEAK OR EQUIVALENT APPROVED BY ENGINEER IN TEAK WOOD CHARGE/IFCI. HARDWARES HARRISONS,EBCO ,GODREJ,EARL BIHARI OR ANY OTHER APPROVED BY ARCHITECT/IFCI. TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 42 of 44 16 FEVICOL,VAMICOL,KTCOL,ARALDITE OR ANY OTHER APPROVED BY ARCHITECT/IFCI. ADHESIVE LAMINATE SUNMICA ,SONEAR,MERINO,OR ANY OTHER APPROVED BY ARCHITECT/IFCI. DECORATIVE VENEERS ALISHAN,DURO,GREEN,CENTURY OR ANY OTHER APPROVED BY ARCHITECT/IFCI. 19 ALUMINIUM SECTIONS HINDALCO, JINDAL OR ANY OTHER APPROVED BY ARCHITECT/IFCI. 20 GLASS SAINT GOBIN,MODI GUARD,ASAHI OR ANY OTHER APPROVED BY ARCHITECT/IFCI 21 BLOCK BOARD & PLY(IS: 710) ALISHAN, DURO, MAYUR (GOLD) OR ANY OTHER APPROVED BY ARCHITECT/IFCI. 17 18 Note:- For any other item required to be incorporated in work , sample shall be got approved from the IFCI/ Architect before actual procurement and commencement of that item of work. LIST OF APPROVED MAKE OR BRANDS FOR ELECTRICAL WORKS LT SWITCH BOARD PANEL : 11 KV CABLE TERMINATION : SWITCH FUSE/FUSE SWITCH UNITS :L&T/HAVELLS 11 KV (UE) 3 CORE ZLPE ARMORED CABLE : CCI/INCAB/RETCO HRC FUSE : HAVELLS/L&T RCCB/ELCB/MCCB : L&T/LEGRAND/HAVELLS LIGHTS : PHILIPS,HAVELLS CHANGE OVER SWITCH : 1.1 KV GRADE PVC INSULATED COPPER WIRE : 1.1 KV GRADE PVC : INSULATED ALUMINIUM CABLE 1.1 KV GRADE PVC INSULATED L&T/MDS/HAVELLS INCAB/CCI/RR CABLE L&T/LEGRAND/HAVELLS FINOLEX/HAVELLS CCI/INCAB/RR CABLE/RETCO TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 43 of 44 ALUMINIUM WIRE &FLEXI CORD :INCAB/NICCO/RR CABLE. MCB DISTRIBUTION BOARD :MDS/L&T/HAVELLS/LEGRAND MCB/MCB TYPE ISOLATOR MDS/HAVELLS/LEGRAND 15/5 AMP MODULAR PLUG :L&T/CRABTREE/LEGRAND 15/5 AMP SWITCH SOCKET :L&T/CRABTREE/LEGRAND CALL BELL/BUZZER : CONA/L.K FUGA FITTINGS : PHILIPS/HAVELLS (LIGHTS),C.G (FAN) CEILING ROSE : ANCHOR/CONA/LEGRAND DATA CABLE AND I.O BOX : D-LINK CC TV/SPEAKER/SMOKE DETECTOR : BOSCH/SONY/PHILIPS TENDER DOCUMENT FOR THE FURNISHING WORK (INTERIOR DECORATION, ELECTRICAL,LAN,FIRE ALARM ,CIVIL & HVAC WORKS ETC IN COMPOSITE) OF REGIONAL OFFICE, IFCI Ltd. AT BHUBANESWAR Page 44 of 44 5'-8" 6' UPS & INVERTER 11' 2'-9" 3' 2'-10" 3'-8" 4'-11" SAFE WASH AREA 9'-6" SERVER 6'-8" 4'-7" 6'-10" STORAGE EXISTING TOILET 12'-3" 3'-11" CEO & M.D 6'-10" 4'-11" 7' 11' 3' 3' 2'-5" REGIONAL HEAD 3'-6" OFFICER T -1 5' 2'-6" BACK STORAGE 6'-6" FULL HEIGHT GLASS PARTITION 12' 5'-1" 4'-2" PANTRY UTILITY 6' " 2'-8 BACK STORAGE 3'-6" BACK STORAGE 10' 3'-2" CONFERENCE 4' 5' OFFICER T -2 LOW HT PARTITION 5' 2'-10" 8' 11' 10' 6'-5" T -3 OFFICER 3' 11' 5' STORE & RECORDS WAITING LOUNGE 2'-8" BACK STORAGE RECEPTION 11' T -4 LOW HT PARTITION 16'-10" 4'-8" MAIN ENTRY 8'0" WIDE PASSAGE INTERIOR LAYOUT DWG. NO. - SNA/IFCI/01/15 SCALE : 1"=8'0" DATE : 22.09.15 ADDRESS : S-3/736,NILADRIVIHAR, CHANDRASEKHARPUR, BHUBANESWAR - 21, MOBILE : 09937147719 , E-MAIL : shaubhagya.nayak@gmail.com IFCI LIMITED FLEXIBLE LED STRIP LIGHTS OF PHILIPS 7'-11 34 " UPS & INVERTER MODULAR METAL CEILING LVL # 9'0" FROM FFL. WOODEN CEILING WITH TRAY & DROP LVL# 8'6" FROM FFL. EXISTING TOILET 6'-10" 7' 6'-8" SERVER GYP BOARD CEILING LVL # 9'0" FROM FFL. WASH AREA GYP BOARD CEILING LVL # 9'0" FROM FFL. WOODEN CEILING WITH TRAY & DROP LVL# 8'6" FROM FFL. 821" CEO & M.D PANTRY 778 " 7' 6' FLEXIBLE LED STRIP LIGHTS OF PHILIPS 22'-3" 812" RECESS MIRROR OPTICS LED SPOT LIGHT OF PHILIPS 7'-11 34" REGIONAL HEAD A/C GRILL/DIFFUSER WOODEN CEILING WITH TRAY & DROP LVL# 8'6" FROM FFL. A/C GRILL/DIFFUSER CONFERENCE WOODEN CEILING WITH TRAY & DROP LVL# 8'6" FROM FFL. 24' 29' 4' 8' 3' GYP BOARD CEILING LVL # 9'0" FROM FFL. FLEXIBLE LED STRIP LIGHTS OF PHILIPS 3'-2" 6'-5" 11' A/C GRILL/DIFFUSER STORE & SAFE ROOM RECESS MIRROR OPTICS LED OF 2'0"X2'0" OF PHILIPS 4'-8" MAIN ENTRY 8'0" WIDE PASSAGE CEILING LAYOUT DWG. NO. - SNA/IFCI/C.L/15 SCALE : 1"=8'0" DATE : 22.09.15 ADDRESS : S-3/736,NILADRIVIHAR, CHANDRASEKHARPUR, BHUBANESWAR - 21, MOBILE : 09937147719 , E-MAIL : shaubhagya.nayak@gmail.com IFCI LIMITED ELECTRICAL LEGEND SYMBOL DESCRIPTION APPD. RECESSED SPOTLIGHT APPD. BRACKET LIGHT APPD. TRACK LIGHT APPD. SURFACE MNTD. LIGHT APPD. TABLE / PEDASTAL LAMP APPROVED DUCTABLE A.C. SPLIT UNIT- FOR TONNAGE REF. PLAN 4'-0" DIA. APPD. CEILING FAN DB (DISTRIBUTION BOX) 1X36W SURFACE MNTD. TUBE COMPUTER POINT SWITCH BOARD SB-1 SB-2 SB-3 SB-4 SWITCH AT SKIRTING LVL=4" HIGH SWITCH AT 2'-0" F.F.L SWITCH AT 3'-0" F.F.L SWITCH AT 4'-6" F.F.L 15 AMP. SOKET 5/15 AMP. SOKET WITH SWITCH TWO WAY SWITCH TELEPHONE POINT DATA POINT(I.O BOX) UPS INPUT & OUTPUT INVERTER APPD. CEILING SUSP. LIGHTS APPD. CALLING BELL APPD. GATE LIGHT PARKING CEILING LIGHT PROJECT : PROPOSED ELECTRICAL LAYOUT PLAN OF REGIONAL OFFICE FOR IFCI LIMITED AT BHUBANESWAR ELECTRICAL LEGEND DWG. NO. - SNA/IFCI/03/15 OPTION: 00 DATE :22.09.15 ARCHITECT : CLIENT : Soubhagya Nayak Associates ADDRESS : S-3/736,NILADRIVIHAR, CHANDRASEKHARPUR, BHUBANESWAR - 21, MOBILE : 09937147719 , E-MAIL : shaubhagya.nayak@gmail.com IFCI LIMITED ELECTRICAL LEGEND SYMBOL DC DESCRIPTION KEY PAD DOOR CONTACT DVR DIGITAL VIDEO RECORDER MD MOTION DETECTOR K.P C.C TV APPROVED DUCTABLE A.C. SPLIT UNIT- FOR TONNAGE REF. PLAN 4'-0" DIA. APPD. CEILING FAN DB (DISTRIBUTION BOX) 1X36W SURFACE MNTD. TUBE COMPUTER POINT SWITCH BOARD SB-1 SB-2 SB-3 SB-4 SWITCH AT SKIRTING LVL=4" HIGH SWITCH AT 2'-0" F.F.L SWITCH AT 3'-0" F.F.L SWITCH AT 4'-6" F.F.L 15 AMP. SOKET 5/15 AMP. SOKET WITH SWITCH TWO WAY SWITCH TELEPHONE POINT DATA POINT(I.O BOX) UPS INPUT & OUTPUT GEYSER OF APPD. CAPACITY AND MAKE APPD. CEILING SUSP. LIGHTS APPD. CALLING BELL APPD. GATE LIGHT PARKING CEILING LIGHT PROJECT : PROPOSED ELECTRICAL LAYOUT PLAN OF REGIONAL OFFICE FOR IFCI LIMITED AT BHUBANESWAR ELECTRICAL LEGEND DWG. NO. - SNA/IFCI/03/15 OPTION: 00 DATE :22.09.15 ARCHITECT : CLIENT : Soubhagya Nayak Associates ADDRESS : S-3/736,NILADRIVIHAR, CHANDRASEKHARPUR, BHUBANESWAR - 21, MOBILE : 09937147719 , E-MAIL : shaubhagya.nayak@gmail.com IFCI LIMITED ELECTRICAL LEGEND SYMBOL K.P VOLUME CONTROL MCP FACP DESCRIPTION KEY PAD VOLUME CONTROL SWITCH MANUAL CALL POINT FIRE PANEL RI RESPONSE INDICATOR HD HEAT DETECTOR SD SMOKE DETECTOR SP CEILING MOUNTED SPEAKER F.H FIRE HOOTER COMPUTER POINT SWITCH BOARD SB-1 SB-2 SB-3 SB-4 SWITCH AT SKIRTING LVL=4" HIGH SWITCH AT 2'-0" F.F.L SWITCH AT 3'-0" F.F.L SWITCH AT 4'-6" F.F.L 15 AMP. SOKET 5/15 AMP. SOKET WITH SWITCH TWO WAY SWITCH TELEPHONE POINT DATA POINT(I.O BOX) UPS INPUT & OUTPUT GEYSER OF APPD. CAPACITY AND MAKE APPD. CEILING SUSP. LIGHTS APPD. CALLING BELL APPD. GATE LIGHT PARKING CEILING LIGHT PROJECT : PROPOSED ELECTRICAL LAYOUT PLAN OF REGIONAL OFFICE FOR IFCI LIMITED AT BHUBANESWAR ELECTRICAL LEGEND DWG. NO. - SNA/IFCI/03/15 OPTION: 00 DATE :22.09.15 ARCHITECT : CLIENT : Soubhagya Nayak Associates ADDRESS : S-3/736,NILADRIVIHAR, CHANDRASEKHARPUR, BHUBANESWAR - 21, MOBILE : 09937147719 , E-MAIL : shaubhagya.nayak@gmail.com IFCI LIMITED FINANCIAL BID Name of Work: TENDER FOR FURNISHING WORK (INTERIOR DECORATION,ELECTRICAL,LAN,FIRE ALARM,CIVIL,HVAC WORK IN COMPOSITE OF REGIONAL OFFICE FOR IFCI LIMITED AT BHUBANESWAR. Bill of Quantities-1 (BOQ-1): “ABSTRACT” DESCRIPTION AMOUNT (Rs.) S. No. 1. BOQ-2 : INTERIOR DECORATION AND FURNISHING WORK 2. BOQ-3 : CIVIL AND FURNITURE WORK 3. BOQ-4: ELECTRICAL/LAN/PA SYSTEM/CCTV/FIRE ALARM/UPS/HVAC/INVERTER WITH BATTERIES ETC. TOTAL AMOUNT( in Figure): Rs. In Words: Signature of Bidder Company Seal: Place: Date: BILL OF QUANTITIES-2 (BOQ-2) FOR INTERIOR DECORATION AND FURNISHING OF REGIONAL OFFICE FOR IFCI LIMITED AT BHAWANI MALL ,SAHEED NAGAR,BHUBANESWAR Quantity Sl.No. 1A Particulars Semi Glazed Full Height Partition (With Laminate) Providing and fixing in position partly glazed full Height Partition work as per drawing ,in frame work at 2’x2’ grind (horizontally and vertically) comprising of 2”x1” Almunium section of heavy gage as per frame work shown in the drawings with 6 mm plywood on both sides finished with 1.5 mm thick laminates of approved shade and colour as shown in drawings. Item to include 12 mm thick glass with etching and frosting as per design and 2”x2”T.W. member for door sides and glass sides and T.W. door frame to take10 mm thick glass with etching and frosting. All exposed T.W. surfaces to be finished in melamine polish of matching laminate colour as directed including all necessary Stainless Steel finish fittings/hardware, wood preservative paint etc. as per list of approved material and as approved by the Project Consultant/Bank complete in all respects.(Note : In case of false ceiling, the vertical members to be fixed with pucca ceiling but the area of partition payable will be below the false ceiling only) 1B 1C Solid Partition (One side Laminate One side Veneer ) Specification same as 1(A) SFT 300.00 SFT 75.00 SFT 230.00 SFT 550.00 Semi Glazed Full Height Partition (Veneer) Specification same as 1(A), The framing shall be finished with 6mm thick plywood on both side and the board skin to be finished with 4.0 mm thk approved veneer with melamine polish including 12 mm thk toughened Glass in etching & frosting with T.W beading all throughout the exposed edges including fixing the glas with studs,grooves,melamine polish to the mouldings .(Notes # Basic cost of veneer Rs.120/SQ.FT.) 2A 315.00 Fully Glazed Partition (With Toughened Glass) Providing , fitting & fixing 12 mm thick toughened glass partition with chemically eaching and frosting as per design.the partiton will be supported with S.S patch panel fittings (Apex Make) as per drawing and design. The exposed edge of the glass partition should be polished to super quality. The work should be completed as per direction of architect including cost of all labour & material 1E SFT Low Height Partition (With Both Side Veneer) Specification same as 1(A), up to 1500 mm Height 1D Unit Doors (Semi Glazed) Unit Rate ( in Rs.) Incl. all Taxes. Amount ( in Rs.) BILL OF QUANTITIES-2 (BOQ-2) FOR INTERIOR DECORATION AND FURNISHING OF REGIONAL OFFICE FOR IFCI LIMITED AT BHAWANI MALL ,SAHEED NAGAR,BHUBANESWAR Quantity Sl.No. 2B 2C 3 4 5 6 Particulars Unit Providing and fixing party glazed doors of sizes as shown in the drawing.The door shutter door shutter shall of 32 mm thick flush shutter of approved make and finished with 4.0 mm thick Veneer (Basic cost Rs.120/SQ.FT) on both sides finished in melamine polish as per architects direction..The shutter will have partly glazed 12mm thick Frosted toughened glass, side beveled ,with vision panel, high polished with body etching/LOGO .The rates are inclusive of approved patch fitting locking system,1 pair of 18" long S.S Handles of approved make,heavy duty Floor spring,Door closure,Dead lock,top pivot,top patch fittings,bottom patch fittings,corner lock with strike plate and euro profile cilinder and all labour, materials, taxes, leads & lift to the place of work executed to the satisfaction of the Architect./IFCI. SFT 150.00 SFT 40.00 SFT 90.00 NOS 8.00 NOS 10.00 SFT 700.00 Flush Doors (Fully Solid) Specification same as 2A ,but with Laminate finish. Main Entrance Door (With Toughened Glass) Providing and fixing fully glazed Aluminium (heavy duty 14 gauge)Doors at the Main Entrance with 6"x2" sections for top & bottom rails, 2"x2" for vertical styles.12mm thk toughened glass with frosting and etching/LOGO shall be fixed in the framing.Rate shall include pad lock,heavy duty floor spring (2 nos),18"long S.S Handles (2 nos),gaskets,top and bottom patch fitting locking systems of approved make. Name Plates Wooden (Personal) Supplying and fixing name plates using S.S finish with blue & light blue letters and border of approved size. Cylindrical Type S.S Dustbin & Flower Pot Providing cylindrical type S.S dustbin and S.S flower pot of size 1'0" dia and 18" height. Gyp Board False Ceiling (With Tray & Drop) False Ceiling (Gypsum Board) Providing & fixing in position false ceiling in Gypboard 12 mm thick (with 3" cornice) for horizontals & Verticals fixed over G.I. frame workas specified by India Gupsm Co. Ltd. including trap doors for A.C. Unit in 18mm thick M. R. Grade Plywood with Stainless Steel hinges & locks withmoulding 1” x 1” for edges including finishing with White Plastic EmulsionPaint etc. complete in all respects.(Note :- Only the plan area will be measured for payment. No extra payment will be made for cutouts, grooves,mouldings etc.) Modular Metal Ceiling Unit Rate ( in Rs.) Incl. all Taxes. Amount ( in Rs.) BILL OF QUANTITIES-2 (BOQ-2) FOR INTERIOR DECORATION AND FURNISHING OF REGIONAL OFFICE FOR IFCI LIMITED AT BHAWANI MALL ,SAHEED NAGAR,BHUBANESWAR Quantity Sl.No. 7 8 9 10 Particulars Unit Providing & fixing in position false ceiling in G.I Tiles metal sheet of Armstrong 600 x 600 mm x 15/16 mm Dune Supreme RH 95 Prima tile with sheihard gride Tegularedge framework as specified by Armstrong Co. with suspenders whereverrequired. Making necessary framework for A. C. ducting, if any, andnecessary cutouts for diffusers and light fittings, taping and finishing toproper line & level, including making grooves and trap doors for A. C. unit G.I Section with Stainless Steel hinges & locks withmoulding 1” x 1” for edges including finishing with White Plastic EmulsionPaint etc. complete in all respects.(Note :- Only the plan area will bemeasured for payment. No extra payment will be made for cutouts, grooves,mouldings etc.) SFT 100.00 SFT 400.00 NOS 1.00 NOS 1.00 False Ceiling (With Ply & Laminate) Providing & fixing in position false ceiling of 9 mm Ply and finished in 1.5 mm thick laminate of approved design form work ,fixed by using 25 mm long dry wall server and to the underside suspended G.I Channelsgrid comprising of suitable size as per site condition and as per manufactures specification.Grid is suspended by G.I soffet cleat(37X27X1.6 MM),using metal expansion fasteners of 12mm dia,35mm deep and connecting clipsand other accessories.(Note :- Only the plan area will be measured for payment. No extra payment will be made for cutouts, grooves,grills of specified sizes etc.).rate shall includes required finishing and pollishing without any cracks. Chief Executive Officer's Table (6'6"X3'0"X2'6") Providing and fixing of counter table of size 6'6"x3'-0"x 2'-6" ,with a side credenza of size 3'10"X1'4"X2'6" and a front drawer unit consisting 3 Nos of drawer units slides on telescopic slider made up of 19 mm th.ply with locking arrangement. The exposed edge surfaces are to be finished with 4.0 mm thick Veneer as per design of approved shade and the inner surface finished with 0.8 mm thick Laminate of approved shade.cablemanager are to be fixed as per drawing and design. The work shall be completed with all labour and material as per drawing and design including all the hardware required. Regional Head's Table (6'6"X3'0"X2'6") Providing and fixing of counter table of size 6'6"x3'-0"x 2'-6" ,with a side credenza of size 3'6"X1'4"X2'6" and a front drawer unit consisting 3 Nos of drawer units slides on telescopic slider made up of 19 mm th.ply with locking arrangement. The exposed edge surfaces are to be finished with 4.0 mm thick Veneer as per design of approved shade and the inner surface finished with 0.8 mm thick Laminate of approved shade.cablemanager are to be fixed as per drawing and design. The work shall be completed with all labour and material as per drawing and design including all the hardware required. Reception Counter Unit Rate ( in Rs.) Incl. all Taxes. Amount ( in Rs.) BILL OF QUANTITIES-2 (BOQ-2) FOR INTERIOR DECORATION AND FURNISHING OF REGIONAL OFFICE FOR IFCI LIMITED AT BHAWANI MALL ,SAHEED NAGAR,BHUBANESWAR Quantity Sl.No. Particulars Unit NOS 1.00 NOS 3.00 RFT 6.00 Providing and fixing in position Reception counter table made out of 19 mm BWR BB for front , top and sides finished with 4.0 mm thk. Veneer . Table will have two drawers made out of 19 mm thk. BWR BB ,4.0 mm Veneer for front,12 mm BWR ply for both sides and 6 mm ply for base and shutter fabricated out of 19 mm BWR BB ,4.0mm thk. Veneer. Drawer should run on Sliding channel.All inside area to be finished with 0.8 mm laminate.All exposed edges to be finished with white beach/white ceader moulding/lipping(as per design)with natural polish.Wire manager (approved colour),Readymade leg rest,black powder coated readymade Key board tray to be provided.The drawer & shutters to be provided with 4" s/s finish handle,godrej multipurpose lock,auto closing hinges etc.Table will have 12mm thk. bevelled glass and 18mm thk.jet black granite for top.19 mm BWR b/b finished with 1.0 mm thk.bruss steel laminate to be provided as shown in drawing.Table front will have some rasied portition finished with 1.0mm thk approved colour laminate as per drawings and Architects instruction. As per specification,design and approval of the Architects. 11 12 13 Officer's Table (5'0"X2'6"X2'6") Providing and fixing of counter table of size 5'0"x2'6"x 2'-6" ,with a side credenza of size 3'0"X1'4"X2'6" and a front drawer unit consisting 3 Nos of drawer units slides on telescopic slider made up of 19 mm th.ply with locking arrangement. The exposed edge surfaces are to be finished with 4.0 mm thick Veneer as per design of approved shade and the inner surface finished with 0.8 mm thick Laminate of approved shade.cablemanager are to be fixed as per drawing and design. The work shall be completed with all labour and material as per drawing and design . Running Table For Server . Providing and fixing of running counter table made up of 19 mm thick ply with drawer unit consisting 3 No’s of drawer units slides on telescopic slider made up of with locking arrangement. The exposed edge surfaces are to be finished with 1.0 mm thick laminates as per design of approved shade and the inner surface to be finished with 0.8 mm thick laminate of approved shade .The work is to be completed with all labour and material including all the hardware required. Conference Room Table (8'0"X4'0"X2'4") Unit Rate ( in Rs.) Incl. all Taxes. Amount ( in Rs.) BILL OF QUANTITIES-2 (BOQ-2) FOR INTERIOR DECORATION AND FURNISHING OF REGIONAL OFFICE FOR IFCI LIMITED AT BHAWANI MALL ,SAHEED NAGAR,BHUBANESWAR Quantity Sl.No. 14 15 16 17 18 Particulars Unit Providing and fixing a table of over all size of top as mentioned above.It shall consist of 19 mm thick BWP Grade ply top as per design (double edge on outer edge with 37 mmX10 mm) thick moulding with teak wood on the edges supported on three boxes of size24"X6" made of 19 mm thick ply inter connected with boxing 4"X6" as approved by the Architect.All external surfaces to be finished with 4.0 mm thick Veneer(Baci of approved shade finished with melamine polishup to the satisfaction of Architect/IFCI. NOS 1.00 SFT 400.00 NOS 7.00 NOS 7.00 SFT 165.00 Low Height & Full Height Storage ( With Veneer ) Providing and fixing of low height storage cabinate having 450 mm. depth made from 19 mm thick ply all side finished with 4.0 mm thick Veneer on the exterior shall be finished with natural melamine polish as per design of approved colour and the inner surface is finished with 0.8mm thk Laminate of approved colour. The work shall be completed with all necessary hardwares i.e, S.S Handles,brass locks,wall catches etc,labour and materials etc. (Notes # Basic cost of veneer Rs.120/SQ.FT) Key Board Tray Providing & supplying metal keyboard tray without Mousepad manufacture by M/S Godrej/EBCO.The Keyboard is pullout type, fixed to channels and screwed to below table top. CPU Trolly Providing & supplying metal CPU trolly manufactured by M/S Godrej/EBCO attached with 4 wheels for holding CPU and smooth movement. Wall Panelling (With Laminate) Encasing to columns , Banking hall etc where ever shown in drawings by fixing 6 mm thick BWP 701 Grade Ply (Alishan,Duro,Mayur) to the frames made out of Heavy duty Aluminium Box sections 50mmX25mm@600mm c/c,both ways horizontally and vertically on the wall by means of nailing or screwing over with 1 mm thick laminate of approved shade fixed by means of adhesive having grooves & necessary white beach beading as directed by the Architect finished with wooden moulding,skirting & Lipping etc. . At places niches shall be created to accommodate 12 mm tk soft board & fabric of approved quality fixed with necessary frame work of wood . Nitches shall be leaped with WB wood which is also melamine polished. The cost includes all the materials, labour, transportation taxes etc., complete for the work. Wall Panelling (With A.C.P) Unit Rate ( in Rs.) Incl. all Taxes. Amount ( in Rs.) BILL OF QUANTITIES-2 (BOQ-2) FOR INTERIOR DECORATION AND FURNISHING OF REGIONAL OFFICE FOR IFCI LIMITED AT BHAWANI MALL ,SAHEED NAGAR,BHUBANESWAR Quantity Sl.No. 19 20 21 22 23 Particulars Unit Providing & Fixing in position aluminum composite panel (ACP) with framing of aluminium tube sections of min 1.5"-1" and 20 gauge 2'-0" C/C both ways. ACP to be in 2' width panels or distributed equally.Panel to be fixed to the frame with 3M or equivalent adhesive.Joint to be finished with silicon based sealant. ACP thickness of 3mm minimun.Aluminium foil thickness to be Min 0.20MM both sides.ALUBOND,EUROBOND,or equivalent ISO certified or approved brands to be used. NOS 275.00 SFT 575.00 RFT 6.00 SFT 16.00 SFT 100.00 Wall Panelling (With Veneer) Providing and fixing framing on wall with 12 mm thick BWP 701 Grade Ply (Alishan,Duro,Sylvan) to the frames made out of Heavy duty Aluminium Box sections 50mmX25mm@600mm c/c,both ways horizontally and vertically on the wall by means of nailing or screwing over finished with 4.0 mm thick VENEER shall be finished with natural melamine polish of minium 2 coats to have desired matt melamine finish where ever specified by the Architect,finished with wooden mouldings,skirtings and Lippings etc,as per the direction of Architect.The shade of Veneer and polishing finish to be got approved from Architect.Measurement of Wall panelling shall be limited upto 6" above false ceiling and no separate payment shall be made for the work above 6" .(Notes # Basic cost of Veneer Rs.120.00/SQ.FT) Pantry Platform in Black Galaxy (With Sink & Cock) Providing and Laying platform of 2'0" width and 2'8" height(Top) above FFL of approved 20 mm thk granite with bull nose edges,supported on a 25 mm thk wooden top.rate shall be inclusive of making cutouts and polishing the edges for18"x18" s.s nirali sink without drain board (medium).A flexible pipe from sink to the nahni trap shall be provided.rate shall be one jaquar continental C.P SWAN NECK TAP with swinging casted. Shutters Below Granite Counters In Pantry Providing & fixing 19 mm thick BWR ply shutters with ply frame,skirting gap shall be maintained,division of shutters shall be made equally.shutters shall be hinged to the framework & finished with 1.0 mm thk laminate of approved shade from outside including other fittings complete Vertical Blinds Providing & Fixing 100 mm wide vertical blinds with proper mechanism of open and close of approved fabric,colour,shade and design of approved make complete as per drawing and direction of Architect (Basic cost # Rs.100/sq.ft),non metallic (fabric) vertical blinds of Mac/Viesta/Arroflex make complete. Wall Plastic Paint. Unit Rate ( in Rs.) Incl. all Taxes. Amount ( in Rs.) BILL OF QUANTITIES-2 (BOQ-2) FOR INTERIOR DECORATION AND FURNISHING OF REGIONAL OFFICE FOR IFCI LIMITED AT BHAWANI MALL ,SAHEED NAGAR,BHUBANESWAR Quantity Sl.No. 24 25 26 27 28 29 Particulars Unit Providing & applying 2 coats of plastic emulsion paint of royale ICI dulux & approved shade on wall, columns, beams, ceiling, etc. of back office hall including locker room, including preparation of surface, sand papering the intermediate coats, including cost of all materials, labour, conveyance,taxes, royalties, scaffolding, watering, curing, sundries, T&P, etc., as per direction of Engineer-in-charge. SFT 550.00 SFT 550.00 RFT 145.00 RFT 85.00 NOS 1.00 SFT 200.00 SFT 100.00 NOS 1.00 Wall Putty Work (With P.O.P Punning) Providing and applying wall puttyputty work punning in order to make the total plastered wall surface perfectly leveled , including cost of all materials,labour, conveyance, taxes, royalties, scaffolding, watering, curing, sundries,T&P, etc., as per direction of Architect/IFCI. Wooden Skirting Providing and fixing 4" wide skirting of beech wood/mahogany/Teak of 1/2" thick finished with melamine polish of approved shade and matching wooden lipping on top/bottom as directed by Architect/IFCI. Granite Frames To Toilet/Pantry Doors/Main Entry Providing and fixing 3/4" thk granite for door frames in vertical jambs and soffit with outer part of 4" width and inner part of 2" width fixed on walls with a difference of 1/2" for door shutter,including machine polish on exposed edges and rounding of corners,necessary backing material,and joint filling of same shade of granite. R.O Water Purifier Supply and Installation of Electric R.O Water Purifier of approved make of KENT/AQUAGUARD,8LTR capacity including plumbing work,material and labour etc complete. Rolling Shutter Boxing (With Laminate) Providing & fixing 3/4" marine ply boxing for existing rolling shutter.Necessary arrangement shall be provided for trap door for smooth operation of shutters and rest is closed with mirror screws.the shutter shall be finished with approved 1.5 mm thick laminate on all exposed sides,enamel paint internally and the rates shall be inclusive of all fittings lke hinges,ball catches,tower bolt (Ebco make) etc Low Height & Full Height Storage ( With Laminate ) Providing and fixing of low height storage cabinate having 450 mm. depth and finished with 1.0 mm th.laminates as per design of approved shadea and the inner surface is finished with 0.8 mm thk Laminate of approved shade. The surfaces are to be finished with as per design The work should be completed according to drawing and design including all labour and materials. made out of 19 mm th. block board. 30 A Plumbing & Sanitary Work Providing and fixing EWC of Hindware with all accessories like toilet seats and cistern with all necessary inner fittings and the interconnection all complete. Unit Rate ( in Rs.) Incl. all Taxes. Amount ( in Rs.) BILL OF QUANTITIES-2 (BOQ-2) FOR INTERIOR DECORATION AND FURNISHING OF REGIONAL OFFICE FOR IFCI LIMITED AT BHAWANI MALL ,SAHEED NAGAR,BHUBANESWAR Quantity Sl.No. Particulars Unit B Providing and fixing Wash basin (Hindware) of 450 x 450 with all internal fittings etc , chain plug and padestal colour white all complete. Providing and fixing angular stop cock ESSCO S.S. finish Providing and fixing Bib cock ESSCO S.S. Finish Providing and fixing Pillar cock ESSCO S.S. finish Providing and fixing floor trap and bottle trap Providing and fixing Soap dispenser Providing and fixing Towel ring/Towel Rod MIRROR FOR TOILET SIZE 2' -0" x 3-'0" Providing and fixing mirrior in toilets made out of 6mm thk. Machine polish glass all over edges mounted over 1/2" thk. Marine ply. The mirror shall be fixed with 1" dia s.s stud.The work to be completed in all respect as per design,direction and approval of the Architect. Jet spray with flex tube/hook,health faucet. Twin peg coat hook Napkin Ring All necessary G.I and C.I pipe lines for Pantry and all interconnecting water lines, waste pipe including bends , elbows what ever necessary to complete the job . The contractor has to inspect the spectic tank and do the necessary repair if needed. Providing and fixing Flatback Urinal of Johnson make. Providing and fixing 19 mm thick black granite machine polish Urinal divider Panelling With Wooden Strips Providing and fixing of wall panelling made with Mahogany/Maple wooden fluted strips as per the design and given a natural mleamine matt finish of approved shade.The size of each strip is 6"x6'0" shall be fixed horizontally with a groove of 6mm,finished with wooden grouts of approved colour.the rates includes labour,materials and polishing etc complete and upto the satisfaction of the Architect/IFCI. NOS 1.00 NOS NOS NOS NOS NOS NOS 2.00 2.00 2.00 2.00 2.00 2.00 SFT 12.00 NOS NOS NOS JOB 2.00 2.00 2.00 1.00 NOS SFT 1.00 10.00 NOS 150.00 C D E F G H I J K L M N 31 TOTAL Unit Rate ( in Rs.) Incl. all Taxes. Amount ( in Rs.) BILL OF QUANTITIES-3 (BOQ-3) FOR CIVIL AND FURNITURE WORK OF REGIONAL OFFICE Sl.No. 1A 2A FOR IFCI LIMITED AT BHAWANI MALL,SAHEED NAGAR,BHUBANESWAR Unit Rate ( in Rs.) Amount Particulars Unit Quantity ( in Rs.) Incl. all Taxes Vitrified Tile Flooring (Repair and Refitting) Providing and Fixing 600mmX600mm polished/un-polished Premium Quality vitrified ties in pattern of approved make/design in hall and other specified areas on existing Terrszo/Kota flooring/Tiles including 4" skirting to masonary walls and columns,laid with tile adhesive as per manufacturers recommendations.The work includes cleaning/levelling and removal of grading ,where ever necessary and dismantaling of old terrazo skirting and providing joints of 3mm thick using company made spacer and then filled with approved adhesive like Laticrete/Epoxy grouts of approved colour including cost of material,labour etc. NOTES # The finished work shall not sound hollow,when tapped with woolen mallet,After cleaning the floor shall be covered with oil free dry sawdust and should be removed only after completion of total renovation work.(Basic Rate of the Tile # 54/- SFT).The work to be complete up to the satisfaction of the Architect/IFCI. Utility Counter (2'0" top wide counter with storage) Providing and laying Utility counter using 25 mm thick BWR Grade ply Top,sides and back with storage units below the counter (450 mm depth).19 mm thick ply shutter with box type self closing higes of approved make and steam beach lipping finished with melamine polish.All external surface to be finished with 1.00 mm thick laminate of approved shade.Division of shutters shall be made equally according to the length of the storage unit.A 19 mm thick coom ply shelf on battens shall be provided in the middle.suitable steam beach moulding with melamine polish shall be provided to the edge of the counter top. The rate shall be inclusive of labour,material and fittings etc. 2C 45.00 JOB 1.00 RFT 3.00 Repairs/Modification(Existing Aluminium Windows) Making necessary modification as suggested by the Architect/IFCI in the existing two track aluminium sliding powder coated / anodised window opening-reducing/increasing the sizes,addition/alteration in window shutter etc.The Frame should be 2" x 1 1/2" wide sections with tracks on all the sides & drain tray system for the bottom frame. The shutters should be of suitable 2" x 1" sections for top & bottom member & 1 5/8" x 1" for vertical with 6 mm. Thk. Modiguard make clear float glass and imported beading shall be used. in addition 2 coats of anti rust paint/powder coating to be provide to the existing window shutters 2B SFT Banks Signage At Main Entry Sl.No. 2D 3 4 5 6 7 8 Particulars Unit Quantity Providing and fixing Digital type Internal signage of size (2'0"x12'0") with acrylic sheet,on both sides of the Main Entrance including the logo of IFCI LIMITED in exposing Digital Letter of approved size including lighting with LED strips/LED Tube ,with necessary aluminium boxing ,26 gauge G.I Sheet at the back with LDR based timer of kakatia energy system or G.E/L&T make.The rate includes the cost of material,labourcharges and fixing etc. SFT 50.00 SFT 105.00 SFT 50.00 NOS 2.00 NOS 2.00 NOS 1.00 SFT 80.00 Banks Signage On Exterior Façade Providing and fixing 30'0"X3'6" acrylic sheet of 12mm thick with stickered letters and its colour as per the drawing for fixing sinage of IFCI LIMITED in exposing Digital Letter with necessary aluminium boxing and framing and fixing on to the glazed outer wall and fixing 3 bracket lights make on to the board with electrical wiring provision on the building.the rates includes the cost of materials,labour charges and fixing etc complete with LDR based Timer of Kakatia energy system or LG/L&T make. Stone Cladding On Wall With first class quality rough stone finish Tiles fixed using approved quality glue with all labour,material etc complete Softscape Elements Providing rectangular Landscape boxes of size in Main Entrance area ,in pot shaped boxing and finishing using 1.0mm thick stainless steel finish mica of ISI Grade and edges finished in hardwood reapers all around and filling a height of 8" width ,filling with white pebbles of 1/2" to3/4" size and inserting 4 nos indoor plants and green creepers.The size of plywood boxing has to be 6'0"X1'6" and height 1'6" using 19 mm marine ply boxing.The rate shall include materials,labour,fiitting and fixing etc complete and as per the direction of the Architect/IFCI. Executive Sofa 3 Seater Sofa for Regional Head,CEO & MD with artificial whote texture Leather Finish of approved make and colour and as per the direction of the Architect/IFCI. Visitors Sofa 3 Seater sofa with leather finish in the Lounge area Providing and fixing two track aluminium sliding powder coated / anodised window. The Frame should be 2" x 1 1/2" wide sections with tracks on all the sides & drain tray system for the bottom frame. The shutters should be of suitable 2" x 1" sections for top & bottom member & 1 5/8" x 1" for vertical with 6 mm. Thk. Modiguard make clear float glass and imported beading shall be used. The tracks will be fixed on 2" x 1" aluminium pipe frame. - (Heavy Duty 2" thick frames (14 guage) - JINDAL / INDAL / HINDALCO" make),complet with all material,labour and fittings,hardwares etc. C.E.O & M.D Chair Unit Rate ( in Rs.) Amount ( in Rs.) Incl. all Taxes Sl.No. 9 10 11 12 13 Particulars Unit Quantity Providing High Back Chair ,M.S arm with powder coated chrome base,gas lift 100 mm ,caster wheel -38/50,PU Leather lite,tilting,dimensions 500 mm in width,480 mm in depth,750 mm height from seat,1150 mm minimum height from ground level in Black/Dark Blue colour of approved make. NOS 1.00 NOS 1.00 NOS 10.00 NOS 12.00 NOS 2.00 NOS 1.00 Regional Head Chair Providing High Back Chair ,M.S arm with powder coated chrome base,gas lift 100 mm ,caster wheel -38/50,PU Leather lite,tilting,dimensions 500 mm in width,480 mm in depth,650 mm height from seat,1150 mm minimum height from ground level in Black/Dark Blue colour of approved make. Officers Chair Providing Medium Back Chairs ,adjustable arm ,gas lift 100 mm ,caster wheel -28/60,PU Leather lite,tilting,dimensions 465 mm in width,430 mm in depth,450 mm height from seat,800 mm minimum height from ground level in Blue colour. Visitors Chair Providing Medium Back Chairs ,adjustable arm ,gas lift 100 mm ,caster wheel -28/60,PU Leather lite,tilting,dimensions 465 mm in width,430 mm in depth,450 mm height from seat,800 mm minimum height from ground level in Blue colour. Pantry Chairs Providing café chair,PP shell pipe frame,powder coated, dimensions 400mm width,470mm depth,465mm height from seat,900mm height from ground. Centre Table A Centre Table of size - 4'0"X2'0"X1'6",Rectangle shaped 19 mm thick marine ply in dark wood veneer finish finish .A rectangle shape wooden base and the top is finished with 12 mm thick toughened glass with machine polished edges .The rates shall include materials,labour etc compmete and upto the satisfaction of the Architect/IFCI TOTAL Unit Rate ( in Rs.) Amount ( in Rs.) Incl. all Taxes BILL OF QUANTITIES-4 (BOQ-4) FOR ELECTRICAL,LAN,FIRE ALARM,UPS,HVAC AND INVERTER ETC. WORK OF REGIONAL OFFICE FOR IFCI LTD, BHUBANESWAR Unit Rate ( in Rs.) Incl. all UNIT QUANTITY AMOUNT (Rs.) SL.No. DESCRIPTION OF ITEMS Taxes. A 1 WIRING TO POINTS Recess conduit wiring to light, ceiling fan, exhaust fan points with (2x1.5 sq mm + 1(1x1sqmm ) PVC single core copper wire in PVC/ Super polythene pipe with galvanized iron junction & switch boxes & clip in type 6 Amp modular type switches with all accessories, T&P & as directed by the Architect/IFCI. i) Primary ( I light/fan controlled by one switch ) 2 3 4 Nos. 40.00 ii) Secondary point (2 lights controlled by 1 switch) iii) Primery point (wall fan controlled by 1 switch and one sockets) 5 Amp. A. Recess conduit wiring to 6 Amp plug socket with switch on existing board as above B. Recess conduit wiring to 5/15 Amp plug socket with switch on separate board as, stabilized power plug above. Recess conduit wiring to call bell point with one gong bell of 6” dia placed at strategic point with 6 Amp switch bell push clip in type modular type fixed on G.I. boxes placed at skirting level for emergency use, the wiring details are as per Sr .no. - 01. The places as located in drawing & as per direction of Architect/IFCI Nos. 20.00 Nos 15.00 Nos. 20.00 Nos 20.00 Set 1.00 The supply to above will be given from 16 Amp switch placed in a modular box at the entrance of the Bank building, which can be operated by Guard. The M.S. box should have hinged door with locking arrangement. The cable in the wall & flooring is to be recessed properly & passed through 1” PVC pipe. The size of the box 200mm x 150mm x 100mm, made out of 18 SWG CRCA sheet properly painted with 2 coats of primer & above it 2 coats of enamel paint. The box contains 16 Amp switch-1 no. & 6 Amp switch- 1no. & 6 Amp socket- 1no. (all flush type) & as per direction of Architect/IFCI Set 1.00 SL.No. DESCRIPTION OF ITEMS 5 Supply of all required materials and wiring to circuits/ submains with following number and sizes of PVC insulated 1100 volt grade standard copper wire run inside pre-laid PVC conduit pipe of ISI mark as required and copper wire as earth continuity conductor and complete in all respect including making good to all damages caused and as per the direction of Consultant/IFCI UNIT Unit Rate ( in Rs.) Incl. all QUANTITY Taxes. A. Recessed wiring with 2x(1x2.5sqmm) +1x(1x1.5sqmm) copper wire B. Recessed wiring with 2x (1x4sqmm) + 1x (1x2.5sqmm) copper wire C. Recessed wiring with 4x (1x10sqmm) + 1x (1x6.0sqmm) copper wire Suppling ,fixing and testing of indoor wall mounted type distribution board of door type of approved make . Mts 278.00 Mts 212.00 Mts 30.00 L.D.B 8 way DP DB Incoming 1 No. 32A DP ELCB Out going 6 No. 6-10 A SP MCB Set 2.00 7 Supply of all required materials and wiring to AC plug point with 4 (1x10sqmm) PVC insulated copper wire run inside screw type PVC conduit pipe with ISI market laid on surfaced/recessed of wall/celling alongwith 1 (1x6sqmm) PVC insulated copper wire as earth continuity conductor complete in all respect including with use of 8.5 TR AC starter, concealed metal boxes with cover, wire, 40A TPN metalclad plug socket, metalic switch box for plug, junction box etc complete with making good the damages caused as required and as per direction of Architect/IFCI. Nos. 1.00 8.0 Supply,installation and testing of timer with contactor ( L&T / Legrand ) make controlling the glowsign board with all accessories complete as required as per direction of Architect/IFCI. The system will be apart of the panel board. Nos 2.00 B COMPUTER WIRING 6 AMOUNT (Rs.) SL.No. DESCRIPTION OF ITEMS 1 Supply of all required materials and wiring to circuits/ submains with following number and sizes of PVC insulated 1100 volt grade standard copper wire run inside pre-laid PVC conduit pipe of ISI mark as required and copper wire as earth continuity conductor and complete in all respect including making good to all damages caused and as per the direction of Consultant/IFCI 2 A. Recessed wiring with 2x(1x2.5sqmm) +1x(1x1.5sqmm) copper wire B. Recessed wiring with 2x (1x4sqmm) + 1x (1x2.5sqmm) copper wire Supplying & fixing of UPS input DB company made & wired with double door arrangement OF APPROVED make) with following arrangement. Incoming 63 amp TPN ELCB– 1 no Mts 285.00 Mts 125.00 SET 1.00 SET 1.00 C.D.B 8 way SPN DB Incoming 1 No. 32A DP ELCB Out going 6No. 6-10A SP MCB SET 2.00 Supplying & fixing of computer terminal boxes made of G.I. fitted with (3nos. of 6 Amp switches + 3 nos. 6Amp socket ), all clip in modular type & as per direction of Architect/IFCI Set 20.00 3 Supplying & fixing of UPS output DB company made & wired with double door arrangement OF APPROVED make) with the following arrangement. Outgoing 40 Amp DP ELCB – 3 nos. (1main & 1 spare). 4 Suppling ,fixing and testing of indoor wall mounted type distribution board of door type of approved make . 5 UNIT Unit Rate ( in Rs.) Incl. all QUANTITY Taxes. AMOUNT (Rs.) Unit Rate ( in Rs.) Incl. all QUANTITY Taxes. SL.No. DESCRIPTION OF ITEMS UNIT 6 Providing and fixing of chemical earth electroad made out of 50mm dia class-B Asahalock or equevalent 2m length with copper plate made out of 600x600x3.15 mm tinned copper plate along with one number 40x5mm tinned copper strip grazed with the plate buried vertically with top edge of the plate at a depth of 1500 mm with arrangements for termination of copper strip of earth continuty conductor including cost of charcole, saltoreign soil, water pouring arrangements brick massionry encloser on top with R.C.C cover complete with labour and material as per direction of Architect/IFCI Set 2.00 7 Supply of all required materials & wiring to clip in modular type 15 /5 amp socket points controlled by 1 no 15 amp switch complete in all respect including making good to damages caused as per direction of EIC for Hub connection supply . Nos 6.00 8 The earth lead by 8sq.mm PVC single core cupper wire in GI pipe to connect from earth electrodes to UPS outgoing earth bus & as per direction of Architect/IFCI. Mts 250.00 C 1 FITTINGS AND FIXTURES Supply,installation and testing of recess lights mirror optics fittings (2x36wt) of size 2'-0"x2'-0" of Philips with all accessories complete assembly of )as required as per direction of Architect/IFCI Model No - RC380B,LED-25-6500,PSE,OD WH Nos. 9.00 2 Supply,installation and testing of GREEN LED spot light mirror optics, fittings (2x18wt) with all accessories complete assembly of Philips ( MODEL No. DN191BLED,6S-4000,PSU WH) as required as per direction of Architect/IFCI. Nos. 36.00 3 Supply,installation and testing of Flexible LED strip of Model - (5M,DLI,30729),5MTR of Philips make along with electronic driver for 30w flexi LED strip SET 8.00 AMOUNT (Rs.) Unit Rate ( in Rs.) Incl. all QUANTITY Taxes. SL.No. DESCRIPTION OF ITEMS UNIT 4 1 X 13W, low loss ballast CFL fitted with lamp FBH 100/113 Providing and fitting single Tube lights patty fittings (1x28) watt ,surface mounting with all accessories complete assembly of Philips ,MODEL NO (ASPIRE,T-5,28 WATT),as required as per the direction of the Architect/IFCI. Nos 2.00 Nos. 10.00 5 6 3 W LED Spot light of PHILIPS/HAVELLS make Nos 20.00 7 Providing and fitting of 450 mm sweep Cabin fan of approved make . Providing and fitting of 450 mm sweep Wall fan of approved make . Providing and fitting of1200 mm sweep celing fan of approved make . Providing and fitting of 400 mm sweep Exhust fan of approved make . Providing and fitting of call bell of approved make . Nos. 4.00 Nos. 6.00 Nos. 1.00 Nos. 2.00 Nos. 4.00 8 9 10 11 D 1 PHONE WIRING/CONFERENCE SYSTEM Supply of all required materials & laying of the Mtrs. following sizes of phone wires of approved make inside the approved size PVC conduit complete in all respect as per instruction of EIC .2 pairs telephone wires 2 Supply , fixing , testing of phone point with suitable Nos. GI boxes with phone , socket complete in all respect as per direction of EIC/IFCI 3 4 5 6 S & I of point wiring for Discussion system comprising of 2x 1.0 sqmm stranded , copper conductor , flexible PVC insulated and PVC Sheathed wire pulled through 20 mm dia .PVC heavy gauge conduits and looped from one speaker to other and to the volume control and control switch wherever applicable and finally terminated at Tag Block. Supply & installation of built in Speaker of Bosch/Sony/Philips make for Chairman unit. Supply and installation of built in speaker of Bosch/Sony/Philips make for Delegate units Supply and installation of Discusion control unit (CU) of Bosch/Sony/Philips make for supply of power for all the delegates and chairman units in the system 60.00 6.00 Pts 8 Nos 1 Nos 4 Nos 1.00 AMOUNT (Rs.) SL.No. DESCRIPTION OF ITEMS UNIT Unit Rate ( in Rs.) Incl. all QUANTITY Taxes. PANEL BOARD . 7 Supply and installation of main LT panel, wall mounted front operated totally enclosed vermin proof, indoor non-drawout-cubicle type power panel fabricated out of 2mm thk CRCA sheet having gasketed hinged cover on each cubicle fully powder coated after 7 Tank treatment, incorporating horizontal and vertical sleeved copper busbars, complete with all internal wiring, danger board, 2 earthing legs, cable chamber etc as required, housing below mentioned switch gears / meter ( GA drawing of the panel got to be approved by Bank / Architect/IFCI) 1No.,125A,FP, Changeover Switch + 1 no. , 125A,TP, MCCB with ELR(0-3A) and CBCT as Incomer 3 nos. 40A & 2nos. 63A, TPN, MCB outgoing 1 no., 0-125A, Ammeter with CTand selector switch 1no., 0-500V, Voltmeter with selector switch and fuse 1Set, TPN, Copper busbars of size 20mm x 5mm thk PVC insulated suitable for 125 Amp load 1 Set, RYB, indicating lamps with resistors and fuses Full Set as above S & I of 200A, MCCB in sheet metal enclosure for 8 9 10 11 main switch near meter and stabiliser input etc. S & I of 200A,FP, Changeover switch in sheet metal enclosure for stabilizer bypass S & I of 125A,FP, Changeover switch in sheet metal enclosure for stabilizer bypass Supply and installation of 35 KVAR APFC panel, floor/wall mounted front operated totally enclosed vermin proof, indoor non-drawout-cubicle type power panel fabricated out of 2mm thk CRCA sheet having gasketed hinged cover on each cubicle fully powder coated with following acessories 1No.125A,TP, MCCB as incomer 1 nos. of 50A 3P contactor & 2 no. 25A 3P contactor 1 nos. 40A MCB & 2 no. 25A MCB 1 nos. 20KVAR & 1no. 10 KVAR & 1no.5 KVAR Capacitor Suitable bus bar for connecting the contactors and MCB's, Capacitors 1.00 SET 1.00 Nos. 1.00 Nos. 1.00 Nos. AMOUNT (Rs.) SL.No. DESCRIPTION OF ITEMS UNIT Unit Rate ( in Rs.) Incl. all QUANTITY Taxes. 1 no. 4 step APFC relay suitable for above arrangement ON/OFF/TRIP push button for each capacitor ON/OFF/TRIP indication lamp for each capacitor 12 13 14 E 1 Set, RYB, indicating lamps with resistors and fuses for incomer. Full Set as above 1.00 S & I of 1100V grade armoured cable having sector / circular shaped aluminium / copper conductor PVC insulated cores, laid up, PVC tape wrapped inner sheathed, GI strip / wire armoured and overall extruded PVC sheathed confirming to IS: 1554, laid on wall or ceiling using GI clamps and spacers as per route shown at site and further as directed by IFCI / Architect in the following sizes. 3 1/2 C x 70 Sq.mm Aluminium Mtrs. 3 1/2 C X 50 Sq.mm Al Cable Mtrs. Earthling as per I.E. rules with 40mm dia G.I. pipe Nos. of 3 mt. Long perforated on all sides with arrangements of light , termination of 600x600x3mm copper plate & 19x3 G.I flat firmly connected to plate with copper nut & bolt , washer etc . The earth pit should be filled with alternate layers of charcoal, salt & soil. The brick masonry chamber is to be covered with CI cover of minimum 300mm x 300mm size with all accessories & as per direction of Engineer-incharge./IFCI Supplying & fixing Earth lead with 8nos. of GI wire. Mtrs. 3 LOCAL AREA NETWORK (LAN) Recess wiring with Cat-6 Lan cable with PVC Mtrs. conduit Supply and fixing of Cat-6 IO box with cover for Nos. LAN Supply and fixing of Cat-6 Patch chord 2 mtr long Nos. 4 5 6 7 Supply and fixing of RJ 11 for voice 9U Data Rack-D-Link 24 Port 10/100 GIGA Switch-D-Link 24 Port patch panel-D-Link F MUSIC - CUM - PA - SYSTEM 1 2 Nos. Nos. Nos. Nos. SET 245.00 185.00 2.00 350.00 150.00 20.00 20.00 20.00 1.00 1.00 1.00 AMOUNT (Rs.) SL.No. 1 2 3 4 5 G 1 2 3 4 5 6 7 DESCRIPTION OF ITEMS UNIT S & I of point wiring for music - cum PA system comprising of 2x 1.0 sqmm stranded , copper conductor , flexible PVC insulated and PVC Sheathed wire pulled through 20 mm dia .PVC pts heavy gauge conduits and looped from one speaker to other and to the volume control and control switch wherever applicable and finally terminated at Tag Block. S & I of Philips / Bosch/Sony make music speaker flush mounted on the false ceiling with proper Nos. clamping arrangement S & I of volume control - cum - ON - OFF switch flush mounted on wall along with other electrical switches .The size and plate of the regulating Nos. knob should match with other switches nearby (PHILIPS/BOSCH/SONY make) S & I of 100 Watts BOSCH/PHILIPS make Central Music System Amplifier and MP3/CD set Player with FM facility of make Samsung/Onida/LG S & I of TV socket point flush mounted on wall / partition including cabling till outside the builing Nos. with connector CCTV/SECURITY ALARM/FIRE ALARM SYSTEM Supply and Installation of Digital Video Recorder(4 channel) of approved make as per the Nos requirement and specifications of the Security Vendor Supply and Laying of RG-11 Unarmoured Co-axial video cable (ISI marked) through 25 mm PVC Pnts conduit (ISI marked) including cost of the conduit with CCTV system Supply & Laying of 2 Core 1.5 Sq.mm Un armoured power cable for power supply to 14.00 cameras-CCTV, Panic Switch,Sensor, Hooters etc. Supply & Laying of 2 Core 1.5 Sq.mm Armoured 15.00 cable for Fire Alarm System S&I of Photo electric(Optical) type Smoke Detector with flashing LED Above the false ceiling where ever required as per the IS standard. S&I of Response indicator for the above false ceiling . Supply,testing and comissioning of Fire alarm 4 zone control panel working on 22 Volt AC complete with S.M.F battery back up with battery charger arrangement. Unit Rate ( in Rs.) Incl. all QUANTITY Taxes. 8 8 4 1 4 1 8 pnts pts no. 8 no. 7 no. 1 AMOUNT (Rs.) SL.No. 8 9 10 H 1.0 2.0 DESCRIPTION OF ITEMS S&I of Heat Detector with flashing LED above the false ceiling where ever required as per drawings and as per IS standards Supply & Laying of 4 Core 14/36 Shielded cable for Security Alarm System for motion sensor and Key pad Supply & Installation of Manual call pont with break glass near Main entrance FIRE EXTINGUISHERS Supply installation testing & commissioning of ISI marked FIRE EXTINGUISHERS ABC type - 2Kg ABC type - 5Kg UNIT Unit Rate ( in Rs.) Incl. all QUANTITY Taxes. no. 3 Pnts 2 Nos 2 No No 1 1 I UPS SYSTEM (NUMARIK/EMERSON MAKE) 1 Online UPS 5.0 KVA of 4 hrs. SMF backup with iron shelve: One No. Quoted price should include iron shelve, installation, all taxes & duties. (Make : Reputed brand with three years onsite warranty) Input Parameters Nominal input voltage 230 Vac 1Phase Line to neutral with 3-wire system (Earth wire) Permissible input voltage range 161 Vac (30%) to 276 Vac (+20%) Nominal Input frequency 50 Hz Permissible input frequency variation +/- 10% Input power factor > 0.99 at 230 Vac input voltage and 4.5kW output load & V i/pTHD < 2% Input Current Distortion - I - THD <= 10% at 230 Vac input voltage Maximum Battery back up time Up to 4 hours. Black Start Available No. of batteries (tubular battery Exide make) (12V) 20 nos. - SMF, 19 nos. - LATB Charging Time (to reach 90% of AH) 12 Hrs to 15 Hrs. Battery Capacity (Adjustable) 100AH. Full Set as above SET 1 TOTAL DESCRIPTION FOR AIR-CONDITIONING Unit Qty. (HVAC) SYSTEM EQUIPMENTS Testing and comissioning Supply of existing air cooled Ceiling Concealed Ductable AC (8.5 TR) having own make hermetic type scroll compressor housed inside the outdoor unit of the plant having microprocessor based control panel for operation & fault diagnosis of the plant in door unit of BLUE STAR make. J AMOUNT (Rs.) SL.No. DESCRIPTION OF ITEMS UNIT Unit Rate ( in Rs.) Incl. all QUANTITY Taxes. 8.5 TR Ductable Unit ANCILLARY WORK 1 a. b 2 3 4 a) b) 5 6 Refrigerant copper piping inter connecting respective condensing unit& Evaporator units with refrigerant grade hard drawn copper tubes complete with liquid line strainer, filter drier, pipe supports complete with insulation etc. Suction line hard drawn cu. Pipe with 9mm thick nitrile rubber tube insulation Liquid line hard drawn cu. Pipe with 6mm thick nitrile rubber tube insulation. Installation with Supports/suspension of condensing unit & Evaporator unit including ribbed neoprene VI pads. (Ductable AC) Hard PVC drain pipe of 25mm dia with 6mm nitrile insulation Design, supply, fabrication & erection of air distribution GSS Ducting in accordance with the approved ducting lay out drawing, complete with all accessories, dampers, guide vanes, support, etc. 24 G GP Sheet 20G GP Sheet Acoustic insulation inside the supply air duct with 12 mm thick rigid board, Tissue paper, & Alu. Perforated sheet. Providing insulation over the ducts with 13 mm thick Nitrile rubber Alu.foil Insulation fix with proper adhesive. 7 Providing & Connecting canvas in mouthpiece. 8 Dynacraft/Premier/carry air or equivalent make linear grills or extruded aluminium section finished with power coated or approved colour. a. b. 1)Grills/Diffuser 2) VCD (22 G.) 9 Laying control copper wire outdoor unit to indoor unit as required completing the work in all respect. 10 6c. X 1.5Sqmm Providing Iron structure/Brick pedestal base for outdoor unit placement for Duct able AC. 11 Commissioning, testing, balancing the system & handling over the same to the owner in satisfactory working condition of duct able AC. 12 Refrigerant R-22 Rft 40 Rft 40 Set 1 Rft 30 Sft Sft 400 300 Sft 150 Sft 400 Nos 1 Sft Sft 80 15 Rft 40 sets 1 LOTS 1 Lot 1 AMOUNT (Rs.) SL.No. DESCRIPTION OF ITEMS 13 Lifting, shifting and Placement of AC unit at their position. K INVERTER BATTERY(MICROTEK/LUMINOUS) 1 Inverter including Battery and Rack One Inverter 2500VA/ 36V with Three 165AH, 12V Tubular Battery Installation & Servicing charge Accessories viz: wire, switch board, catching, switch, sockets etc. Total UNIT Unit Rate ( in Rs.) Incl. all QUANTITY Taxes. sets 1 sets 1 AMOUNT (Rs.)