GPRAR6N – 154T5HOSTC – 120V – ERS – 8` – RECW/PR/GFW

Transcription

GPRAR6N – 154T5HOSTC – 120V – ERS – 8` – RECW/PR/GFW
GPRAR6N-1T5 Perimeter Series
Recessed Perimeter Drywall or Grid Mounted
Regressed Asymmetric Ambient Illumination
REFELECTOR
SEMI SPECULAR
OR WHITE
WALL BRACKET
HEAVY GA. INTEGRAL BULK HEAD
Scan or click bar code to view product
photos and updates.
10 5/8”
Table of contents
Pg 2. Photometric Report
EXTRUDED ALUM
HOUSING
7/8” K.O.
Pg 3. Illumination Options
6”
Pg 4. Lamp Barrier
Pg 5. Lamp Stagger
7/8” DIA THRU HOLE
@ EA - END WIRE ACCESS
WALL
9.5”
Pg 7. Run Length
Pg 8. Mounting Styles
3.66”
3.5”
Pg 15. Wall Interface
PLASTER BLEND
DRYWALL OR
CEILING PANEL
Construction
GFW FLANGE 15/16”
PLASTER RAIL*
Patent Pending, USPTO docket # 54842.8002.US00
6”
Housing: Extruded aluminum body, 6063T5, 0.090” minimum thickness. Available in one piece, unbroken lengths up to 8”’
Joiner System: Precision formed alignment spline with factory installed bolts for a hairline seam. No light leaks.
Ballast: Osram - Sylvania or equal electronic programmed rapid start ballast with less than 10% THD is standard: ERS. For dimming ballast
(DIM), specify model if available.
Mounting: Shall be perimeter mounted to wall via Plaster Rail (*PR) or Adjustment Trim (AT) and recessed into a ceiling system. Power feed is
accomplished through knockouts in housing. Designated fixtures can be ganged together mechanically and electrically in continuous rows.
Electrical
UL listed wiring and components throughout. Housing is completely wired with quick-connect plugs at all mating joints and individually tested. All fixtures
bear
UL & cUL Dry Location labels. Damp Location labels are available. Specify DL in the Options field.
Optical Performance
Reflectors: Shall be formed diffuse high reflectance aluminum (G)
Finish
Housing assembly is electrostatically sprayed with high solids aliphatic two component polyurethane to an average thickness of 2 mils. over acid
etching primer. White high gloss or semi gloss are standard. Consult factory for other finishes. Specify WH for White High Gloss or WSG for White
Semi Gloss in trim color and finish fields
Standard Features
Manufacturer
Gammalux
Ballast
ERS Elec. RS <10% THD
DIM Elec. Dimming
(Specify Model)
Optic Location
C Ceiling Line, R Regressed
Lamp Type
T8, T5, T5HO
Lamp Barrier
B Barrier
N None
Voltage
120V
277V
UNIV
Trim
Color
Wall Interface
PR Plaster Rail*
AT Adjustment Trim
Mounting Method
REC Recessed Intra-Wall
RECW Recessed
Wall to Wall**
W White
Shielding
OP Open
Finish
H High Gloss
SGSemi Gloss
GPRAR6N – 154T5HOSTC – 120V – ERS – 8' – RECW/PR/GFW – OP– WH – XX
Lamp Stagger
Aperture
6''
Illumination
A Ambient
AR Ambient w/
Roll-out
reflector
G Grazing
Family
P Perimeter
Nominal
Wattage
Blank none
STC Custom lamp stagger
throughout entire run**
STT Std. lamp stagger, run
ends in telescoping fixture.
32 (4' - T8)
28 (4’ - T5), 54 (4’ - T5HO)
Lamps in Cross Section
1 or 2
Lighting Systems
Run Length
Indicate
nominal run
length or
pattern
(2’ min)
Ceiling Interface
GFW Gyp or Grid
Flanged, wire suspension
GMR Gyp Mud trim, Rod
suspension
Options
GLR - Fuse w/ holder
BPE - Battery Pack Em. kit
DL - UL Damp Label
2CKT - Dual circuiting
EMERG - Emergency Ckt.
CP - Chicago Plenum
compliant
*Plaster Rail must be perfectly straight on wall.
**When STC or RECW are specified, exact field dimensions (at the wall height where the Plaster
Rail will be installed) are required from installing contractor on approved submittal drawings.
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
1
Recessed Perimeter Series
GPRAR6N-1T5
Photometric Report
SUMMARY DATA
CANDELA PLOT
EFFICIENCY (Total):
EFFICIENCY (Downlight):
EFFICIENCY (Uplight):
CIE CLASSIFICATION:
SPACING CRITERION (90-Deg.):
LUMENS/LAMP:
NO. OF LAMPS:
LUMINOUS OPENING: RECTANGULAR
Width:
Length:
Height:
INPUT WATTS:
90
59.6 %
59.6 %
0.0 %
DIRECT
1.30
5000
1
80
250
70
4.00 (Feet)
0.83
0.72
59
500
60
750
50
ZONAL LUMEN SUMMARY
Zone
0 - 30
0 - 40
0 - 60
60 - 90
0 - 90
90 - 180
0 - 180
Lumens % Lamp % Luminaire
821.7
16.4
27.6
1348.1
27.0
45.2
2431.4
48.6
81.6
548.8
11.0
18.4
2980.3
59.6
100.0
0.0
0.0
0.0
2980.3
59.6
100.0
1000
40
1250
10
Bilaterally Symmetric
Solid: 180-0 Degrees Dashed: 90-270 Degrees
AVERAGE LUMINANCE
(Candelas / Square Meter)
Angle
0
45
55
65
75
85
0
3580
2494
1149
507
314
105
22.5
3580
2430
1675
516
321
111
45
3580
2432
2223
926
362
133
67.5
3580
2731
2428
2033
963
186
90
3580
3108
2928
2534
1890
744
112.5
3580
1859
1478
1128
770
255
135
3580
1338
1168
903
496
163
157.5
3580
1253
1088
739
415
137
20
30
180
3580
1282
1095
695
412
131
COEFFICIENT OF UTILIZATION TABLE
Effective Floor Cavity Reflectance = 20%
Pcc
Pw ...
RCR
0
1
2
3
4
5
6
7
8
9
10
70
.71
.65
.59
.54
.49
.45
.42
.39
.36
.34
.32
80
50 30
.71
.62
.54
.48
.42
.38
.34
.31
.28
.26
.24
.71
.60
.50
.43
.37
.33
.29
.26
.23
.21
.19
10
70
.71
.58
.47
.39
.33
.29
.25
.22
.20
.18
.16
.69
.63
.58
.53
.48
.44
.41
.38
.35
.33
.31
Lighting Systems
70
50 30
.69
.61
.53
.47
.42
.37
.34
.30
.28
.25
.24
.69
.59
.50
.42
.37
.32
.29
.25
.23
.21
.19
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0
.69
.57
.47
.39
.33
.28
.25
.22
.20
.18
.16
.66
.58
.51
.45
.40
.36
.32
.29
.27
.25
.23
.66
.56
.48
.41
.36
.32
.28
.25
.23
.21
.19
.66
.55
.45
.38
.33
.28
.25
.22
.19
.17
.16
.63
.56
.49
.43
.39
.35
.31
.29
.26
.24
.22
.63
.55
.47
.40
.35
.31
.27
.25
.22
.20
.19
.63
.53
.44
.38
.32
.28
.24
.22
.19
.17
.16
.61
.54
.47
.42
.37
.34
.31
.28
.26
.24
.22
.61
.53
.45
.39
.34
.30
.27
.24
.22
.20
.18
.61
.52
.43
.37
.32
.28
.24
.21
.19
.17
.16
.60
.50
.42
.36
.30
.26
.23
.20
.18
.16
.15
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
2
Illumination Options
A The Ambient illumination optic is designed to
bounce light off the top of the wall, back out into
occupied space. The reflector material is white
high reflectance, low gloss painted steel. Steel
reflectors are pre-installed in 4’ increments. For
the best effect, use no lamp barrier in the fixture.
AR The Ambient illumination w/Roll-out reflector
optic is designed to bounce light off the top of
the wall, back out into occupied space. The
reflector material is a white high reflectance film
shipped separate from fixtures, in lengths up to
40’. For best effect, use no lamp barrier in the
fixture.
G The Grazing illumination optic is designed to
drive light directly down through the fixture
aperture. The reflector material is high
reflectance, semi specular aluminum.
Aluminum reflectors are pre-installed in 4’
increments. For the best effect, use the lamp
barrier in the fixture. Gammalux Recommends
a level 5 wall finish. The Grazing illumination
optic will highlight all inconsistencies in the wall
surface.
Lighting Systems
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
3
Lamp Barrier
N No lamp barrier is used. Light will shine
directly onto the top of the wall.
Warning - Lamps will be visible to viewers in a
a mirror’s reflection or if the fixture is mounted
across the junction of a corridor.
B The lamp Barrier is designed to block direct
view of the lamp from any angle below the
ceiling line. This barrier reflects light upward,
onto the fixture’s main reflector for further
reflection directly down through the fixture’s
aperture. The lamp barrier is hinged for simple
relamping and features tool-less removal for
fixture maintenance. The best use of the lamp
barrier is in conjunction with the Grazing
illumination reflector system. Gammalux
Recommends a level 5 wall finish. The Grazing
illumination optic will highlight all inconsistencies
in the wall surface.
Lighting Systems
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
4
Lamp Stagger
Blank: Lamps are butted socket-to-socket throughout the length of the run. Depending on the run
length and the type of lamp specified, this may result in inconsistent illumination in the run.
T8, One - Lamp cross section
26'-4"
*3' Lamps
**
*
*
8'-0"
8'-0"
6'-0"
4'-4"
STC: Lamps are Custom-staggered throughout the entire run. An ideal range of 3” to 6” lamp
stagger is sought, using 4’ nominal length lamps. In some cases, use of a 3’ or 2’ nominal length
lamp may be required at the end of the run to allow for the most ideal lamp staggering and
producing the most consistent illumination throughout the run. Exact field dimensions (at the wall
height where the Plaster rail will be installed) are required. Fixtures with custom staggered lamps are
built to exact length and have no field adjustment capability.
One - Lamp, T5, T5HO
8'-8 21/32"
Two - Lamp, T5, T5HO
8'-8 21/32"
One - Lamp, T8
8'-8 21/32"
Two - Lamp, T8
*
*
8'-8 21/32"
Lighting Systems
26'-2"
8'-8 21/32"
8'-8 21/32"
26'-2"
*3' Lamps
*
*
8'-8 21/32"
8'-8 21/32"
26'-2"
*3' Lamp
*
8'-8 21/32"
8'-8 21/32"
26'-2"
*
8'-8 21/32"
*3' Lamps
*
8'-8 21/32"
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
5
Lamp Stagger (cont’d)
STT: Lamp stagger is pre-set at 4” overlap in all but the last fixture in the run. The last fixture in the
run is a Telescoping module which receives the overlapping lamp from the previous fixture in the
run and also features a sliding lamp. This sliding lamp can be moved to the end of the telescoping
module. Telescoping modules have a 12” range of adjustability.
26'-2"
One- lamp T5, T5HO
7'-0"
7'-0"
TELE
5'-2"
7'-0"
26'-2"
Two - lamp T5, T5HO
8'-0"
*
*
8'-0"
*
*
*3' Lamps
*
TELE *
4'-2"
6'-0"
26'-2"
*3' Lamps
One- lamp T8
7'-4"
*
7'-4"
7'-4"
4'-2"
*
26'-2"
Two - lamp T8
8'-0"
Lighting Systems
*
8'-0"
*3' Lamps
**
*
*
6'-0"
*
4'-2"
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
6
Run Length
Specify fixtures in nominal run lengths. The level of detail required from the installing contractor is
directly associated with the Lamp Stagger selection:
STC - Housings are built in custom lengths to create a perfect end-to-end installation of
fixtures. However, the as-built field dimensions of the walls may not match the architect’s
designed dimensions exactly. Therefore, factory drawings will be produced showing the
designed nominal run lengths and sent to the installing contractor for written verification
or correction. Manufacturing of fixtures does not start until the final set of approved
drawings (with field dimensions) comes back from the installing contractor. Dimensions
must be measured at the wall height where the Plaster Rail will be installed. Fixtures are
built to exact length and have no field adjustment capability.
26'-2"
*
*
8'-8 21/32"
*
8'-8 21/32"
*3' Lamps
*
8'-8 21/32"
Blank or STT - Exact field dimensions are NOT required. Factory drawings will show the run
of fixtures and telescoping module in such a configuration that the specified (nominal) run
length is located as close as possible to the center of the telescoping fixture’s range of
adjustability. This eliminates the need for accurate field dimensions and allows for some
construction variance in the field.
26'-2"
Two - lamp T8
*3' Lamps
**
*
*
*
8'-0"
Lighting Systems
8'-0"
6'-0"
*
4'-2"
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
7
Perimeter Series Mounting Styles
Mounting style from page 1: RECW/PR/GMR
Fixture is recessed above the ceiling line and against a side wall (RECW). The
exposed portion of the side wall should be finished to match the rest of the wall.
The Plaster Rail (PR) is positioned with mud ribs facing down, allowing it to be
‘mudded’ into the face of the back wall. The fixture bottom features a mud flange
(GMR), allowing it to be ‘mudded’ into the drywall or plaster ceiling. Exact field
dimensions are required.
When mudding in the Plaster Rail,
Gammalux recommends a Level 5
wall finish.
• PLASTER RAIL IS INSTALLED ONTO WALL BEFORE THE WALL IS FINISHED.
• PLASTER OR JOINT COMPOUND IS BLENDED DOWN THE WALL,
EMBEDDING THE BOTTOM OF THE PLASTER RAIL INTO THE WALL.
• WALLS ARE FINISHED PER ARCHITECTURAL INSTRUCTIONS (SIDE WALL
SHOULD BE FINISHED 4” ABOVE THE CEILING LINE AND 6” FROM THE
BACK WALL).
• FIXTURE IS INSTALLED AND SUSPENDED FROM ABOVE.
• CEILING IS INSTALLED, FIXTURE BOTTOM FLANGE IS MUDDED OVER.
• FIXTURE IS MASKED AND CEILING IS FINISHED PER ARCHITECTURAL
INSTRUCTIONS.
Download
installation
instructions
Lighting Systems
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
8
Perimeter Series Mounting Styles
Mounting style from page 1: RECW/PR/GFW
Fixture is recessed above the ceiling line and against a side wall (RECW). The
exposed portion of the side wall should be finished to match the rest of the wall. The
Plaster Rail (PR) is positioned with mud ribs facing down, allowing it to be ‘mudded’
into the face of the back wall. The fixture bottom features a 1” flange (GFW),
allowing it to rest under the ceiling material. Exact field dimensions are required.
When mudding in the Plaster Rail,
Gammalux recommends a Level 5
wall finish.
• PLASTER RAIL IS INSTALLED ONTO WALL BEFORE THE WALL IS FINISHED.
• PLASTER OR JOINT COMPOUND IS BLENDED DOWN THE WALL,
EMBEDDING THE BOTTOM OF THE PLASTER RAIL INTO THE WALL.
• WALLS ARE FINISHED PER ARCHITECTURAL INSTRUCTIONS (SIDE WALL
SHOULD BE FINISHED 4” ABOVE THE CEILING LINE AND 6” FROM THE
BACK WALL).
• FIXTURE IS INSTALLED AND SUSPENDED FROM ABOVE.
• CEILING IS INSTALLED, FIXTURE’S BOTTOM FLANGE RESTS UNDER
CEILING MATERIAL.
• IF NECESSARY, FIXTURE IS MASKED AND CEILING IS FINISHED PER
ARCHITECTURAL INSTRUCTIONS.
Download
installation
instructions
Lighting Systems
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
9
Perimeter Series Mounting Styles
Mounting style from page 1: RECW/PR/GFW
Fixture is recessed above the ceiling line and against a side wall (RECW). The
exposed portion of the side wall should be finished to match the rest of the wall. The
Plaster Rail (PR) is positioned with mud ribs facing up and not used. The plaster
rail flange is visible on the back wall. The fixture bottom features a 1” flange (GFW),
allowing it to rest under the ceiling material. Exact field dimensions are required.
• WALLS ARE FINISHED PER ARCHITECTURAL INSTRUCTIONS. (SIDE
WALL
SHOULD BE FINISHED 4” ABOVE THE CEILING LINE AND 6” FROM THE
BACK WALL).
• PLASTER RAIL IS INSTALLED ONTO WALL AFTER THE WALL IS FINISHED.
MUD RIBS ARE FACING UP AND ARE NOT USED, PLASTER RAIL’S FLANGE
IS VISIBLE ON THE BACK WALL.
• FIXTURE IS INSTALLED AND SUSPENDED FROM ABOVE.
• CEILING IS INSTALLED, FIXTURE’S BOTTOM FLANGE RESTS UNDER
CEILING MATERIAL.
• IF NECESSARY, FIXTURE IS MASKED AND CEILING IS FINISHED PER
ARCHITECTURAL INSTRUCTIONS.
Download
installation
instructions
Lighting Systems
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
10
Perimeter Series Mounting Styles
Mounting style from page 1: RECW/PR/GMR
Fixture is recessed above the ceiling line and against a side wall (RECW). The
exposed portion of the side wall should be finished to match the rest of the wall. The
Plaster Rail (PR) is positioned with mud ribs facing up and not used. The plaster
rail flange is visible on the back wall. The fixture bottom features a mud flange
(GMR), allowing it to be ‘mudded’ into the drywall or plaster ceiling. Exact field
dimensions are required.
Drywall, or Plaster ceiling
• WALLS ARE FINISHED PER ARCHITECTURAL INSTRUCTIONS. (SIDE WALL
SHOULD BE FINISHED 4” ABOVE THE CEILING LINE AND 6” FROM THE
BACK WALL).
• PLASTER RAIL IS INSTALLED ONTO WALL AFTER THE WALL IS FINISHED.
MUD RIBS ARE FACING UP AND ARE NOT USED, PLASTER RAIL’S FLANGE
IS VISIBLE ON THE BACK WALL.
• FIXTURE IS INSTALLED AND SUSPENDED FROM ABOVE.
• CEILING IS INSTALLED, FIXTURE’S BOTTOM FLANGE IS MUDDED OVER.
• FIXTURE IS MASKED AND CEILING IS FINISHED PER ARCHITECTURAL
INSTRUCTIONS.
Download
installation
instructions
Lighting Systems
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
11
Perimeter Series Mounting Styles
Mounting style from page 1: RECW/PR/GMR
Fixture is recessed above the ceiling line and IS NOT touching a side wall (REC).
The Plaster Rail (PR) is positioned with mud ribs facing up and not used. The
plaster rail flange is visible on the back wall. The fixture’s bottom trim and endcaps
feature a mud flange (GMR), allowing them to be ‘mudded’ into the drywall or
plaster ceiling.
• WALLS ARE FINISHED PER ARCHITECTURAL INSTRUCTIONS.
• PLASTER RAIL IS INSTALLED ONTO WALL AFTER THE WALL IS FINISHED.
MUD RIBS ARE FACING UP AND ARE NOT USED, PLASTER RAIL’S FLANGE
IS VISIBLE ON THE BACK WALL.
• FIXTURE IS INSTALLED AND SUSPENDED FROM ABOVE.
• CEILING IS INSTALLED, FIXTURE’S BOTTOM FLANGE IS MUDDED OVER.
• FIXTURE IS MASKED AND CEILING IS FINISHED PER ARCHITECTURAL
INSTRUCTIONS.
Download
installation
instructions
Lighting Systems
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
12
Perimeter Series Mounting Styles
Mounting style from page 1: REC/PR/GFW
Fixture is recessed above the ceiling line and IS NOT touching a side wall (REC).
The Plaster Rail (PR) is positioned with mud ribs facing up and not used. The
plaster rail flange is visible on the back wall. The fixture’s bottom trim and endcaps
feature a 1” flange (GFW), allowing them to rest under the ceiling material.
• WALLS ARE FINISHED PER ARCHITECTURAL INSTRUCTIONS.
• PLASTER RAIL IS INSTALLED ONTO WALL AFTER THE WALL IS FINISHED.
MUD RIBS ARE FACING UP AND ARE NOT USED, PLASTER RAIL’S FLANGE
IS VISIBLE ON THE BACK WALL.
• FIXTURE IS INSTALLED AND SUSPENDED FROM ABOVE.
• CEILING IS INSTALLED, FIXTURE’S BOTTOM FLANGE RESTS UNDER
CEILING MATERIAL.
• IF NECESSARY, FIXTURE IS MASKED AND CEILING IS FINISHED PER
ARCHITECTURAL INSTRUCTIONS.
Download
installation
instructions
Lighting Systems
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
13
Perimeter Series Mounting Styles
Due to the complexity of feathering in plaster down and to the side of the wall,
Gammalux does not recommend mudding in the Plaster Rail when fixtures are NOT
being installed wall-to-wall.
Lighting Systems
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
14
Wall Interface
PR The Plaster Rail* is a patent-pending invention of Gammalux Systems (USPTO Docket #
54842.8002.US00). This extruded aluminum element allows for the fixtures to be mounted directly
to the wall while eliminating the gaps that are created by putting a perfectly straight housing along
a built wall that is slightly imperfect. Using appropriate fasteners and hitting studs where possible, the
Plaster Rail should be shimmed from a straight installation on the wall before the mud ribs are covered
with plaster or other compound which is then feathered down the wall. This corrects minor
inconsistencies in the wall’s straightness and provides a mechanism for the fixture’s reflector assembly
to join directly to the wall. This results in Total Architectural Integration, a perfectly straight and clean
look at the ceiling line. Because imperfections in a flat wall will be illuminated, Gammalux recommends
a Level 5 wall finish
1) Plaster Rail is affixed to wall at a predetermined location prior to finishing.
2) Plaster or other compound is blended over
the lower portion of the Rail and feathered
down the wall, eliminating minor
inconsistencies in wall straightness.
3) The wall is textured and finished. leaving a
perfectly straight channel, ready to receive
the fixture’s reflector assembly.
4) The run of fixtures and ceiling are installed.
The fixture’s reflector assembly snaps directly
into the Plaster Rail just above the painted
portion of the wall. Gaps between the fixtures
and wall are eliminated, resulting in
Total Architectural Integration.
Lighting Systems
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
15
Wall Interface (cont’d)
AT The Adjustment Trim is a supplemental flange that is affixed directly to the wall. It is flexible so
that it can follow the gradual curvature of a built drywall construction wall. The Adjustment Trim
eliminates the traditional gap found between most competitor fixtures and the wall.
1) Adjustment Trim is added to the wall at a
pre-determined height.
2) The bottom of the fixture’s reflector
assembly rests on the Adjustment Trim,
providing 1/2” adjustability to allow for minor
variances in wall straightness.
While this Adjustment Trim does accommodate for minor inconsistencies in wall straightness, it can
not correct deep pits. In cases where there is a small gap created between the back of the
Adjustment Trim and the wall, a thin bead of caulking or other compound should be used to fill in
that gap.
WALL
CAULKING
Lighting Systems
TRIM
248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288
E-mail: info@gammalux.com Website: http://www.gammalux.com
Gammalux products comply with ARRA Buy American requirements
16