GPRAR6N – 154T5HOSTC – 120V – ERS – 8` – RECW/PR/GFW
Transcription
GPRAR6N – 154T5HOSTC – 120V – ERS – 8` – RECW/PR/GFW
GPRAR6N-1T5 Perimeter Series Recessed Perimeter Drywall or Grid Mounted Regressed Asymmetric Ambient Illumination REFELECTOR SEMI SPECULAR OR WHITE WALL BRACKET HEAVY GA. INTEGRAL BULK HEAD Scan or click bar code to view product photos and updates. 10 5/8” Table of contents Pg 2. Photometric Report EXTRUDED ALUM HOUSING 7/8” K.O. Pg 3. Illumination Options 6” Pg 4. Lamp Barrier Pg 5. Lamp Stagger 7/8” DIA THRU HOLE @ EA - END WIRE ACCESS WALL 9.5” Pg 7. Run Length Pg 8. Mounting Styles 3.66” 3.5” Pg 15. Wall Interface PLASTER BLEND DRYWALL OR CEILING PANEL Construction GFW FLANGE 15/16” PLASTER RAIL* Patent Pending, USPTO docket # 54842.8002.US00 6” Housing: Extruded aluminum body, 6063T5, 0.090” minimum thickness. Available in one piece, unbroken lengths up to 8”’ Joiner System: Precision formed alignment spline with factory installed bolts for a hairline seam. No light leaks. Ballast: Osram - Sylvania or equal electronic programmed rapid start ballast with less than 10% THD is standard: ERS. For dimming ballast (DIM), specify model if available. Mounting: Shall be perimeter mounted to wall via Plaster Rail (*PR) or Adjustment Trim (AT) and recessed into a ceiling system. Power feed is accomplished through knockouts in housing. Designated fixtures can be ganged together mechanically and electrically in continuous rows. Electrical UL listed wiring and components throughout. Housing is completely wired with quick-connect plugs at all mating joints and individually tested. All fixtures bear UL & cUL Dry Location labels. Damp Location labels are available. Specify DL in the Options field. Optical Performance Reflectors: Shall be formed diffuse high reflectance aluminum (G) Finish Housing assembly is electrostatically sprayed with high solids aliphatic two component polyurethane to an average thickness of 2 mils. over acid etching primer. White high gloss or semi gloss are standard. Consult factory for other finishes. Specify WH for White High Gloss or WSG for White Semi Gloss in trim color and finish fields Standard Features Manufacturer Gammalux Ballast ERS Elec. RS <10% THD DIM Elec. Dimming (Specify Model) Optic Location C Ceiling Line, R Regressed Lamp Type T8, T5, T5HO Lamp Barrier B Barrier N None Voltage 120V 277V UNIV Trim Color Wall Interface PR Plaster Rail* AT Adjustment Trim Mounting Method REC Recessed Intra-Wall RECW Recessed Wall to Wall** W White Shielding OP Open Finish H High Gloss SGSemi Gloss GPRAR6N – 154T5HOSTC – 120V – ERS – 8' – RECW/PR/GFW – OP– WH – XX Lamp Stagger Aperture 6'' Illumination A Ambient AR Ambient w/ Roll-out reflector G Grazing Family P Perimeter Nominal Wattage Blank none STC Custom lamp stagger throughout entire run** STT Std. lamp stagger, run ends in telescoping fixture. 32 (4' - T8) 28 (4’ - T5), 54 (4’ - T5HO) Lamps in Cross Section 1 or 2 Lighting Systems Run Length Indicate nominal run length or pattern (2’ min) Ceiling Interface GFW Gyp or Grid Flanged, wire suspension GMR Gyp Mud trim, Rod suspension Options GLR - Fuse w/ holder BPE - Battery Pack Em. kit DL - UL Damp Label 2CKT - Dual circuiting EMERG - Emergency Ckt. CP - Chicago Plenum compliant *Plaster Rail must be perfectly straight on wall. **When STC or RECW are specified, exact field dimensions (at the wall height where the Plaster Rail will be installed) are required from installing contractor on approved submittal drawings. 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 1 Recessed Perimeter Series GPRAR6N-1T5 Photometric Report SUMMARY DATA CANDELA PLOT EFFICIENCY (Total): EFFICIENCY (Downlight): EFFICIENCY (Uplight): CIE CLASSIFICATION: SPACING CRITERION (90-Deg.): LUMENS/LAMP: NO. OF LAMPS: LUMINOUS OPENING: RECTANGULAR Width: Length: Height: INPUT WATTS: 90 59.6 % 59.6 % 0.0 % DIRECT 1.30 5000 1 80 250 70 4.00 (Feet) 0.83 0.72 59 500 60 750 50 ZONAL LUMEN SUMMARY Zone 0 - 30 0 - 40 0 - 60 60 - 90 0 - 90 90 - 180 0 - 180 Lumens % Lamp % Luminaire 821.7 16.4 27.6 1348.1 27.0 45.2 2431.4 48.6 81.6 548.8 11.0 18.4 2980.3 59.6 100.0 0.0 0.0 0.0 2980.3 59.6 100.0 1000 40 1250 10 Bilaterally Symmetric Solid: 180-0 Degrees Dashed: 90-270 Degrees AVERAGE LUMINANCE (Candelas / Square Meter) Angle 0 45 55 65 75 85 0 3580 2494 1149 507 314 105 22.5 3580 2430 1675 516 321 111 45 3580 2432 2223 926 362 133 67.5 3580 2731 2428 2033 963 186 90 3580 3108 2928 2534 1890 744 112.5 3580 1859 1478 1128 770 255 135 3580 1338 1168 903 496 163 157.5 3580 1253 1088 739 415 137 20 30 180 3580 1282 1095 695 412 131 COEFFICIENT OF UTILIZATION TABLE Effective Floor Cavity Reflectance = 20% Pcc Pw ... RCR 0 1 2 3 4 5 6 7 8 9 10 70 .71 .65 .59 .54 .49 .45 .42 .39 .36 .34 .32 80 50 30 .71 .62 .54 .48 .42 .38 .34 .31 .28 .26 .24 .71 .60 .50 .43 .37 .33 .29 .26 .23 .21 .19 10 70 .71 .58 .47 .39 .33 .29 .25 .22 .20 .18 .16 .69 .63 .58 .53 .48 .44 .41 .38 .35 .33 .31 Lighting Systems 70 50 30 .69 .61 .53 .47 .42 .37 .34 .30 .28 .25 .24 .69 .59 .50 .42 .37 .32 .29 .25 .23 .21 .19 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 .69 .57 .47 .39 .33 .28 .25 .22 .20 .18 .16 .66 .58 .51 .45 .40 .36 .32 .29 .27 .25 .23 .66 .56 .48 .41 .36 .32 .28 .25 .23 .21 .19 .66 .55 .45 .38 .33 .28 .25 .22 .19 .17 .16 .63 .56 .49 .43 .39 .35 .31 .29 .26 .24 .22 .63 .55 .47 .40 .35 .31 .27 .25 .22 .20 .19 .63 .53 .44 .38 .32 .28 .24 .22 .19 .17 .16 .61 .54 .47 .42 .37 .34 .31 .28 .26 .24 .22 .61 .53 .45 .39 .34 .30 .27 .24 .22 .20 .18 .61 .52 .43 .37 .32 .28 .24 .21 .19 .17 .16 .60 .50 .42 .36 .30 .26 .23 .20 .18 .16 .15 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 2 Illumination Options A The Ambient illumination optic is designed to bounce light off the top of the wall, back out into occupied space. The reflector material is white high reflectance, low gloss painted steel. Steel reflectors are pre-installed in 4’ increments. For the best effect, use no lamp barrier in the fixture. AR The Ambient illumination w/Roll-out reflector optic is designed to bounce light off the top of the wall, back out into occupied space. The reflector material is a white high reflectance film shipped separate from fixtures, in lengths up to 40’. For best effect, use no lamp barrier in the fixture. G The Grazing illumination optic is designed to drive light directly down through the fixture aperture. The reflector material is high reflectance, semi specular aluminum. Aluminum reflectors are pre-installed in 4’ increments. For the best effect, use the lamp barrier in the fixture. Gammalux Recommends a level 5 wall finish. The Grazing illumination optic will highlight all inconsistencies in the wall surface. Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 3 Lamp Barrier N No lamp barrier is used. Light will shine directly onto the top of the wall. Warning - Lamps will be visible to viewers in a a mirror’s reflection or if the fixture is mounted across the junction of a corridor. B The lamp Barrier is designed to block direct view of the lamp from any angle below the ceiling line. This barrier reflects light upward, onto the fixture’s main reflector for further reflection directly down through the fixture’s aperture. The lamp barrier is hinged for simple relamping and features tool-less removal for fixture maintenance. The best use of the lamp barrier is in conjunction with the Grazing illumination reflector system. Gammalux Recommends a level 5 wall finish. The Grazing illumination optic will highlight all inconsistencies in the wall surface. Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 4 Lamp Stagger Blank: Lamps are butted socket-to-socket throughout the length of the run. Depending on the run length and the type of lamp specified, this may result in inconsistent illumination in the run. T8, One - Lamp cross section 26'-4" *3' Lamps ** * * 8'-0" 8'-0" 6'-0" 4'-4" STC: Lamps are Custom-staggered throughout the entire run. An ideal range of 3” to 6” lamp stagger is sought, using 4’ nominal length lamps. In some cases, use of a 3’ or 2’ nominal length lamp may be required at the end of the run to allow for the most ideal lamp staggering and producing the most consistent illumination throughout the run. Exact field dimensions (at the wall height where the Plaster rail will be installed) are required. Fixtures with custom staggered lamps are built to exact length and have no field adjustment capability. One - Lamp, T5, T5HO 8'-8 21/32" Two - Lamp, T5, T5HO 8'-8 21/32" One - Lamp, T8 8'-8 21/32" Two - Lamp, T8 * * 8'-8 21/32" Lighting Systems 26'-2" 8'-8 21/32" 8'-8 21/32" 26'-2" *3' Lamps * * 8'-8 21/32" 8'-8 21/32" 26'-2" *3' Lamp * 8'-8 21/32" 8'-8 21/32" 26'-2" * 8'-8 21/32" *3' Lamps * 8'-8 21/32" 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 5 Lamp Stagger (cont’d) STT: Lamp stagger is pre-set at 4” overlap in all but the last fixture in the run. The last fixture in the run is a Telescoping module which receives the overlapping lamp from the previous fixture in the run and also features a sliding lamp. This sliding lamp can be moved to the end of the telescoping module. Telescoping modules have a 12” range of adjustability. 26'-2" One- lamp T5, T5HO 7'-0" 7'-0" TELE 5'-2" 7'-0" 26'-2" Two - lamp T5, T5HO 8'-0" * * 8'-0" * * *3' Lamps * TELE * 4'-2" 6'-0" 26'-2" *3' Lamps One- lamp T8 7'-4" * 7'-4" 7'-4" 4'-2" * 26'-2" Two - lamp T8 8'-0" Lighting Systems * 8'-0" *3' Lamps ** * * 6'-0" * 4'-2" 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 6 Run Length Specify fixtures in nominal run lengths. The level of detail required from the installing contractor is directly associated with the Lamp Stagger selection: STC - Housings are built in custom lengths to create a perfect end-to-end installation of fixtures. However, the as-built field dimensions of the walls may not match the architect’s designed dimensions exactly. Therefore, factory drawings will be produced showing the designed nominal run lengths and sent to the installing contractor for written verification or correction. Manufacturing of fixtures does not start until the final set of approved drawings (with field dimensions) comes back from the installing contractor. Dimensions must be measured at the wall height where the Plaster Rail will be installed. Fixtures are built to exact length and have no field adjustment capability. 26'-2" * * 8'-8 21/32" * 8'-8 21/32" *3' Lamps * 8'-8 21/32" Blank or STT - Exact field dimensions are NOT required. Factory drawings will show the run of fixtures and telescoping module in such a configuration that the specified (nominal) run length is located as close as possible to the center of the telescoping fixture’s range of adjustability. This eliminates the need for accurate field dimensions and allows for some construction variance in the field. 26'-2" Two - lamp T8 *3' Lamps ** * * * 8'-0" Lighting Systems 8'-0" 6'-0" * 4'-2" 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 7 Perimeter Series Mounting Styles Mounting style from page 1: RECW/PR/GMR Fixture is recessed above the ceiling line and against a side wall (RECW). The exposed portion of the side wall should be finished to match the rest of the wall. The Plaster Rail (PR) is positioned with mud ribs facing down, allowing it to be ‘mudded’ into the face of the back wall. The fixture bottom features a mud flange (GMR), allowing it to be ‘mudded’ into the drywall or plaster ceiling. Exact field dimensions are required. When mudding in the Plaster Rail, Gammalux recommends a Level 5 wall finish. • PLASTER RAIL IS INSTALLED ONTO WALL BEFORE THE WALL IS FINISHED. • PLASTER OR JOINT COMPOUND IS BLENDED DOWN THE WALL, EMBEDDING THE BOTTOM OF THE PLASTER RAIL INTO THE WALL. • WALLS ARE FINISHED PER ARCHITECTURAL INSTRUCTIONS (SIDE WALL SHOULD BE FINISHED 4” ABOVE THE CEILING LINE AND 6” FROM THE BACK WALL). • FIXTURE IS INSTALLED AND SUSPENDED FROM ABOVE. • CEILING IS INSTALLED, FIXTURE BOTTOM FLANGE IS MUDDED OVER. • FIXTURE IS MASKED AND CEILING IS FINISHED PER ARCHITECTURAL INSTRUCTIONS. Download installation instructions Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 8 Perimeter Series Mounting Styles Mounting style from page 1: RECW/PR/GFW Fixture is recessed above the ceiling line and against a side wall (RECW). The exposed portion of the side wall should be finished to match the rest of the wall. The Plaster Rail (PR) is positioned with mud ribs facing down, allowing it to be ‘mudded’ into the face of the back wall. The fixture bottom features a 1” flange (GFW), allowing it to rest under the ceiling material. Exact field dimensions are required. When mudding in the Plaster Rail, Gammalux recommends a Level 5 wall finish. • PLASTER RAIL IS INSTALLED ONTO WALL BEFORE THE WALL IS FINISHED. • PLASTER OR JOINT COMPOUND IS BLENDED DOWN THE WALL, EMBEDDING THE BOTTOM OF THE PLASTER RAIL INTO THE WALL. • WALLS ARE FINISHED PER ARCHITECTURAL INSTRUCTIONS (SIDE WALL SHOULD BE FINISHED 4” ABOVE THE CEILING LINE AND 6” FROM THE BACK WALL). • FIXTURE IS INSTALLED AND SUSPENDED FROM ABOVE. • CEILING IS INSTALLED, FIXTURE’S BOTTOM FLANGE RESTS UNDER CEILING MATERIAL. • IF NECESSARY, FIXTURE IS MASKED AND CEILING IS FINISHED PER ARCHITECTURAL INSTRUCTIONS. Download installation instructions Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 9 Perimeter Series Mounting Styles Mounting style from page 1: RECW/PR/GFW Fixture is recessed above the ceiling line and against a side wall (RECW). The exposed portion of the side wall should be finished to match the rest of the wall. The Plaster Rail (PR) is positioned with mud ribs facing up and not used. The plaster rail flange is visible on the back wall. The fixture bottom features a 1” flange (GFW), allowing it to rest under the ceiling material. Exact field dimensions are required. • WALLS ARE FINISHED PER ARCHITECTURAL INSTRUCTIONS. (SIDE WALL SHOULD BE FINISHED 4” ABOVE THE CEILING LINE AND 6” FROM THE BACK WALL). • PLASTER RAIL IS INSTALLED ONTO WALL AFTER THE WALL IS FINISHED. MUD RIBS ARE FACING UP AND ARE NOT USED, PLASTER RAIL’S FLANGE IS VISIBLE ON THE BACK WALL. • FIXTURE IS INSTALLED AND SUSPENDED FROM ABOVE. • CEILING IS INSTALLED, FIXTURE’S BOTTOM FLANGE RESTS UNDER CEILING MATERIAL. • IF NECESSARY, FIXTURE IS MASKED AND CEILING IS FINISHED PER ARCHITECTURAL INSTRUCTIONS. Download installation instructions Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 10 Perimeter Series Mounting Styles Mounting style from page 1: RECW/PR/GMR Fixture is recessed above the ceiling line and against a side wall (RECW). The exposed portion of the side wall should be finished to match the rest of the wall. The Plaster Rail (PR) is positioned with mud ribs facing up and not used. The plaster rail flange is visible on the back wall. The fixture bottom features a mud flange (GMR), allowing it to be ‘mudded’ into the drywall or plaster ceiling. Exact field dimensions are required. Drywall, or Plaster ceiling • WALLS ARE FINISHED PER ARCHITECTURAL INSTRUCTIONS. (SIDE WALL SHOULD BE FINISHED 4” ABOVE THE CEILING LINE AND 6” FROM THE BACK WALL). • PLASTER RAIL IS INSTALLED ONTO WALL AFTER THE WALL IS FINISHED. MUD RIBS ARE FACING UP AND ARE NOT USED, PLASTER RAIL’S FLANGE IS VISIBLE ON THE BACK WALL. • FIXTURE IS INSTALLED AND SUSPENDED FROM ABOVE. • CEILING IS INSTALLED, FIXTURE’S BOTTOM FLANGE IS MUDDED OVER. • FIXTURE IS MASKED AND CEILING IS FINISHED PER ARCHITECTURAL INSTRUCTIONS. Download installation instructions Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 11 Perimeter Series Mounting Styles Mounting style from page 1: RECW/PR/GMR Fixture is recessed above the ceiling line and IS NOT touching a side wall (REC). The Plaster Rail (PR) is positioned with mud ribs facing up and not used. The plaster rail flange is visible on the back wall. The fixture’s bottom trim and endcaps feature a mud flange (GMR), allowing them to be ‘mudded’ into the drywall or plaster ceiling. • WALLS ARE FINISHED PER ARCHITECTURAL INSTRUCTIONS. • PLASTER RAIL IS INSTALLED ONTO WALL AFTER THE WALL IS FINISHED. MUD RIBS ARE FACING UP AND ARE NOT USED, PLASTER RAIL’S FLANGE IS VISIBLE ON THE BACK WALL. • FIXTURE IS INSTALLED AND SUSPENDED FROM ABOVE. • CEILING IS INSTALLED, FIXTURE’S BOTTOM FLANGE IS MUDDED OVER. • FIXTURE IS MASKED AND CEILING IS FINISHED PER ARCHITECTURAL INSTRUCTIONS. Download installation instructions Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 12 Perimeter Series Mounting Styles Mounting style from page 1: REC/PR/GFW Fixture is recessed above the ceiling line and IS NOT touching a side wall (REC). The Plaster Rail (PR) is positioned with mud ribs facing up and not used. The plaster rail flange is visible on the back wall. The fixture’s bottom trim and endcaps feature a 1” flange (GFW), allowing them to rest under the ceiling material. • WALLS ARE FINISHED PER ARCHITECTURAL INSTRUCTIONS. • PLASTER RAIL IS INSTALLED ONTO WALL AFTER THE WALL IS FINISHED. MUD RIBS ARE FACING UP AND ARE NOT USED, PLASTER RAIL’S FLANGE IS VISIBLE ON THE BACK WALL. • FIXTURE IS INSTALLED AND SUSPENDED FROM ABOVE. • CEILING IS INSTALLED, FIXTURE’S BOTTOM FLANGE RESTS UNDER CEILING MATERIAL. • IF NECESSARY, FIXTURE IS MASKED AND CEILING IS FINISHED PER ARCHITECTURAL INSTRUCTIONS. Download installation instructions Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 13 Perimeter Series Mounting Styles Due to the complexity of feathering in plaster down and to the side of the wall, Gammalux does not recommend mudding in the Plaster Rail when fixtures are NOT being installed wall-to-wall. Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 14 Wall Interface PR The Plaster Rail* is a patent-pending invention of Gammalux Systems (USPTO Docket # 54842.8002.US00). This extruded aluminum element allows for the fixtures to be mounted directly to the wall while eliminating the gaps that are created by putting a perfectly straight housing along a built wall that is slightly imperfect. Using appropriate fasteners and hitting studs where possible, the Plaster Rail should be shimmed from a straight installation on the wall before the mud ribs are covered with plaster or other compound which is then feathered down the wall. This corrects minor inconsistencies in the wall’s straightness and provides a mechanism for the fixture’s reflector assembly to join directly to the wall. This results in Total Architectural Integration, a perfectly straight and clean look at the ceiling line. Because imperfections in a flat wall will be illuminated, Gammalux recommends a Level 5 wall finish 1) Plaster Rail is affixed to wall at a predetermined location prior to finishing. 2) Plaster or other compound is blended over the lower portion of the Rail and feathered down the wall, eliminating minor inconsistencies in wall straightness. 3) The wall is textured and finished. leaving a perfectly straight channel, ready to receive the fixture’s reflector assembly. 4) The run of fixtures and ceiling are installed. The fixture’s reflector assembly snaps directly into the Plaster Rail just above the painted portion of the wall. Gaps between the fixtures and wall are eliminated, resulting in Total Architectural Integration. Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 15 Wall Interface (cont’d) AT The Adjustment Trim is a supplemental flange that is affixed directly to the wall. It is flexible so that it can follow the gradual curvature of a built drywall construction wall. The Adjustment Trim eliminates the traditional gap found between most competitor fixtures and the wall. 1) Adjustment Trim is added to the wall at a pre-determined height. 2) The bottom of the fixture’s reflector assembly rests on the Adjustment Trim, providing 1/2” adjustability to allow for minor variances in wall straightness. While this Adjustment Trim does accommodate for minor inconsistencies in wall straightness, it can not correct deep pits. In cases where there is a small gap created between the back of the Adjustment Trim and the wall, a thin bead of caulking or other compound should be used to fill in that gap. WALL CAULKING Lighting Systems TRIM 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Website: http://www.gammalux.com Gammalux products comply with ARRA Buy American requirements 16