078446-01 Fire-Resistive Joint Systems
Transcription
078446-01 Fire-Resistive Joint Systems
SUBMITTAL REVIEW SHEET PROJECT: Canyon View Medical Plaza - Core & Shell DATE ISSUED: 3/2/13 S U B M I T T AL #: 078446-01 S U B M I T T AL T I T L E : Fire-Resistive Joint Systems C O N T R AC T O R ’ S S U B M I T T AL # : 078446-01 Owner: Development Solutions Group 1623 Blake Street Suite 300 Denver, CO 80202 Architect: Boulder Associates Contractor: GH Phipps 5995 Greenwood Plaza Blvd Suite 100 Greenwood Village, CO 80111 Architect’s Project #: 112039.00 1426 Pearl Street Suite 300 Boulder, CO 80302 File: G3 - Submittals The attached submittal was received electronically. The information contained herein is a representation of the original electronic document. A. Reviewed B. Not reviewed C. Reviewed and noted ✔ D. Resubmit ✔ E. Do not resubmit F. Resubmit for files The Architect’s review is for the sole purpose of aiding the contractor. The Architect is not responsible for correctness of dimensions, quantities, details, application or fabrication of any part of the Work, nor for any deviations from the Contract Documents. The Architect’s action does not constitute acceptance of any deviations from the requirements of the Contract Documents. Notes: - Boulder Associates comments in Blue only. - Both 1hr and 2hr conditions exist on this project, but primarily 2hr. Confirm UL assembly is sufficient for 2 hr condition. - GC to coordinate slip track clearances required with MEP Sub-contractors for 3D Coordination effort. Ensure MEP work is sufficiently clear of slip track & gyp. bd. to allow vertical movement. Issued by: Jeff Beardsley Signature: TRANSMITTAL 5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO 80111-4710 303-571-5377 303-629-7467 (fax) PROJECT: TO: DATE: 02/27/2013 GJMC-Grand Junction Medical Center Boulder Associates 1426 Pearl St #300 Boulder CO 80302 ATTN: Jeff Beardsley Ph/Fax: 303-499-7795 No. 12J2007-0103 RE: JOB: WE ARE SENDING: SUBMITTED FOR: 092900-Framing, Drywall and Insula 12J2007 ACTION TAKEN: Shop Drawings Approval Approved as Submitted Letter Your Use Approved as Noted Prints As Requested Returned After Loan Change Order Review and Comment Resubmit Submit Plans SENT VIA: Samples Returned Specifications / Product Data Attached Returned for Corrections Other: Separate Cover Via: Due Date: 03/13/2013 NOTES: Item Package Code Submittal 092900 078446-01 Rev. Copies Date 1 02/27/2013 Description Status Fire-Resistive Joint Systems - Product Data Architect Review CC: Signed: Brady McQuinn SUBMITTAL Head-of-Wall Deflection Track and Firestop System Manufacturer (800) 394-9875 ph 12098 County Rd. 150, Kimball, MN 55353 (320) 398-7660 fax info@firetrak.com www.firetrak.com Description The Fire Trak System consists of the Fire Trak ceiling runner with a shoulder offset the thickness of the wall material. A second piece of wall material is fitted tight to the roof or floor deck and then attached to the shoulder. This allows the deck and the Fire Trak ceiling runner to move in relation to the wall studs and allows the overlapping piece of wall material attached to the Fire Trak to slide over the primary wall material. Benefits Fire Trak 1 Hr. Shadowline Standard Wall - 1” Deflection Fire Trak is a fire rated Head-of-Wall Joint that has passed current fire and cycle tests at U.L. without fire caulk or spray. The system is classified and listed for use with U-400 series walls and is good for both roof and floor assemblies. Code Compliance The Fire Trak System meets all standard building codes and its unique design and exceptional performance are widely recognized and accepted by Building Officials. Fire Trak has U.L. listings for standard walls, cavity walls and shaft walls. It is tested and listed both parallel and perpendicular to the roof and/or floor deck. Test Standards: U.L. 2079 - Tests for Fire Resistance of Building Joint Systems Fire Trak 2 Hr. Cavity Shadowline Shaft Wall - 2” Deflection ASTM E1966 - Standard Test Method for Fire Resistive Joint Systems Cycling Requirements: The test assemblies were cycled 500 times, 100 cycles at 30 CPM and 400 cycles at 10 CPM. The system has Class I, II and III cycling capabilities. Movement Capabilities The Fire Trak System does not require fire caulk or spray to achieve a fire rating. This allows the Fire Trak System substantially greater movement capabilities than other systems. The Fire Trak System achieves a full 100% compression and/or extension and has been tested and listed with U.L. for deflection up to 6”. Fire Rated Condition: Up to 3” of Compression and 3” of Extension Fire Trak 2 Hr. Shadowline Standard Wall - 6” Deflection Up to 6” of Compression or Extension Patented System U.S. Patent No.’s 5,471,805 and 5,755,066 cover the Fire Trak System. Creating a shoulder on a track to attach an overlapping board for the purpose of joint movement is part of Fire Trak’s patented assembly and its use constitutes patent infringement. Availability U.S. PATENT NO’S 5,471,805 AND 5,755,066 Major Credit Cards are accepted. There is a 24 hour lead time on standard profiles. 800.394.9875 www.firetrak.com SUBMITTAL PAGE 1 OF 2 2008 U.L. Listings Type To Be Determined By Deck Type On Job SUBMITTAL % Compression Actual (Deflection) Compression Movement (Deflection) by “ 1” compression and 1“ extension (2 ” range of motion)* HW-D-0060 Standard wall HW-D-0061 Cavity wall HW-D-0117 Standard & Cavity walls HW-D-0118 Standard & Cavity walls HW-D-0119 Shaft wall HW-D-0120 Shaft wall HW-D-0400 Shaft wall Perpendicular and parallel against steel and concrete decks Perpendicular and parallel against steel and concrete decks Perpendicular to metal decks with flute filled with cementious fireproofing Perpendicular to metal decks with flute filled with fire caulk or fire spray Perpendicular and parallel against steel and concrete decks Perpendicular and parallel against steel and concrete decks Parallel under steel beam 1 to 3 hour 100% 1“ 1 to 3 hour 100% 1“ 1 and 2 hour 100% 1“ 1 and 2 hour 100% 1“ 1 to 3 hour 100% 1“ 1 to 3 hour 100% 1“ 1 and 2 hour 100% 1“ 1 to 3 hour 100% 3“ 1 to 3 hour 100% 3“ 1 and 2 hour 100% 3“ 1 and 2 hour 100% 3“ 3” compression and 3“ extension (6” range of motion)* HW-D-1011 Standard wall HW-D-1012 Cavity wall HW-D-1019 Standard & Cavity walls HW-D-1020 Standard & Cavity walls Perpendicular and parallel against steel and concrete decks Perpendicular and parallel against steel and concrete decks Perpendicular to metal decks with flute filled with cementious fireproofing Perpendicular to metal decks with flute filled with fire caulk or fire spray * Tracks can be configured to any deflection between 1” and 6”. Head Detail Steel Specifications UL HW-D-0060 TOP OF METAL DECK MINERAL FIBER BOTTOM OF METAL DECK SEE U.L. LISTINGS FOR SEALANT OPTIONS FIRE TRAK SHADOWLINE 5/8" TYPE 'X' G.W.B. METAL STUD Perpendicular to Metal Deck 1 Hr. Rating - 1” Deflection 20 Gauge (.0356 min thickness) galvanized steel Conforms to ASTM C-645 Steel Conforms to ASTM A-653, Minimum 33,000 ksi yield strength Galvanized in accordance with ASTM A-924, G-40 18 Gauge (.0466 min thickness) galvanized steel Conforms to ASTM C-645 Steel Conforms to ASTM A-653, Minimum 33,000 ksi yield strength Galvanized in accordance with ASTM A-924, G-60 16 Gauge (.0575 min thickness) galvanized steel Conforms to ASTM C-645 Steel Conforms to ASTM A-653, Minimum 50,000 ksi yield strength Galvanized in accordance with ASTM A-924, G-60 Submittal Approvals Job Name: Contractor: Approved By: Canyon View Medical Center TP Acoustics, Inc. Date: 800.394.9875 February 20th, 2013 www.firetrak.com SUBMITTAL PAGE 2 OF 2
Similar documents
Submittal - Firetrak
Perpendicular to metal decks with flute filled with cementious fireproofing Perpendicular to metal decks with flute filled with fire caulk or fire spray Perpendicular and parallel against steel and...
More information