Geothermal Heat Pump Product Catalog
Transcription
Geothermal Heat Pump Product Catalog
ENERGY DISTRIBUTION Geothermal Heat Pump Product Catalog Environmentally-friendly products that produce, distribute and store energy for the most efficient homes and buildings. Geothermal Heat Pump Product Catalog Table of Contents Packaged Two-Stage Vertical Water-To-Air Units.......................................................................................................3 Packaged Two-Stage Horizontal Water-To-Air Units.................................................................................................5 Two-Stage Units Water-To-Water..................................................................................................................................7 Packaged Two-Stage Combination.................................................................................................................................9 Two-Stage Split System.................................................................................................................................................11 Downflow Kits for RXT/RCT Units...........................................................................................................................12 Hydronic Air Handler..................................................................................................................................................13 Hydronic A-Coils..........................................................................................................................................................13 DX Split System A-Coils for Dual Fuel Application..................................................................................................14 DX Split System Air Handler........................................................................................................................................14 Field-Installed External Electric (Duct) Heaters (RHT Series)...............................................................................15 Thermostats....................................................................................................................................................................15 Field-Installed Internal Electric Heaters.....................................................................................................................15 Air Pads...........................................................................................................................................................................16 Flow Centers...................................................................................................................................................................17 Replacement Pumps......................................................................................................................................................19 Hose Kits.........................................................................................................................................................................19 Close Loop Adapter Fittings........................................................................................................................................20 Open Loop (Well Water) Accessories.........................................................................................................................21 Replacement Optional Filers.......................................................................................................................................22 Filter Rack......................................................................................................................................................................22 Miscellaneous Installation Accessories......................................................................................................................23 Software..........................................................................................................................................................................23 Geothermal Heat Pump Product Catalog 2 September 2012 Packaged Two-Stage Vertical Water-to-Air Heat Pumps Roth two-stage vertical water-to-air heatpump: 2 to 6 ton capacity •Unique Multi-position cabinet that allows field configuration of: •Left or Right Return Air Plenum •Upflow or Downflow Supply Air •Non-Ozone depleting R-410A Refrigerant •Removable access panels for easy unit service •High performance micro channel air coil •ECM blower motor •Easily accessible top mounted controls •Corrosion proof molded high impact plastic drain pan •ETL certified to UL & CSA standards, AHRI certified to ISO standards. •Copper coaxial heat exchanger, flow switch protected •Auto retry on system fault to eliminate nuisance service calls •High efficiency two-stage Copeland Ultratech scroll compressors •10/5/5 Standard unit warranty: •10 years– Compressor and refrigeration circuit components •5 years- Unit warranty •5 years- Warranty service allowance WATER-TO-AIR HEAT PUMPS - COPPER COIL with DESUPERHEATER Part # 2380002000 2380002001 2380002002 2380002003 2380002004 Description Tons/ Compatibility Vertical 2-stage packaged with ECM, copper coil, 2 desuperheater Vertical 2-stage packaged with ECM, copper coil, 3 desuperheater Vertical 2-stage packaged with ECM, copper coil, 4 desuperheater Vertical 2-stage packaged with ECM, copper coil, 5 desuperheater Vertical 2-stage packaged with ECM, copper coil, 6 desuperheater Nomenclature Weight lbs RXT024C11MM1CSS 440 RXT036C11MM1CSS 440 RXT048C11MM1CSS 530 RXT060B11MM1CSS 530 RXT072B11MM1CSS 530 Nomenclature Weight lbs RXT024C10MM1CSS RXT036C10MM1CSS RXT048C10MM1CSS RXT060B10MM1CSS RXT072B10MM1CSS 440 440 530 530 530 WATER-TO-AIR HEAT PUMPS - COPPER COIL without DESUPERHEATER Part # Description 2380002005 2380002006 2380002007 2380002008 2380002009 Vertical 2-stage packaged with ECM, copper coil Vertical 2-stage packaged with ECM, copper coil Vertical 2-stage packaged with ECM, copper coil Vertical 2-stage packaged with ECM, copper coil Vertical 2-stage packaged with ECM, copper coil Geothermal Heat Pump Product Catalog Tons/ Compatibility 2 3 4 5 6 3 September 2012 WATER-TO-AIR HEAT PUMPS - CUPRO NICKEL COIL with DESUPERHEATER Part # Description 2380002010 Vertical 2-stage packaged with ECM, cupro nickel coil, desuperheater Vertical 2-stage packaged with ECM, cupro nickel coil, desuperheater Vertical 2-stage packaged with ECM, cupro nickel coil, desuperheater Vertical 2-stage packaged with ECM, cupro nickel coil, desuperheater Vertical 2-stage packaged with ECM, cupro nickel coil, desuperheater 2380002011 2380002012 2380002013 2380002014 Tons/ Compatibility 2 Nomenclature Weight lbs RXT024C11MM1NSS 440 3 RXT036C11MM1NSS 440 4 RXT048C11MM1NSS 530 5 RXT060B11MM1NSS 530 6 RXT072B11MM1NSS 530 WATER-TO-AIR HEAT PUMPS - CUPRO NICKEL COIL without DESUPERHEATER Part # Description 2380002015 Vertical 2-stage packaged with ECM, cupro nickel coil 2380002016 Vertical 2-stage packaged with ECM, cupro nickel coil Vertical 2-stage packaged with ECM, cupro nickel coil 2380002017 2380002018 2380002019 Vertical 2-stage packaged with ECM, cupro nickel coil Vertical 2-stage packaged with ECM, cupro nickel coil Geothermal Heat Pump Product Catalog Tons/ Compatibility 2 Nomenclature Weight lbs RXT024C10MM1NSS 440 3 RXT036C10MM1NSS 440 4 RXT048C10MM1NSS 530 5 RXT060B10MM1NSS 530 6 RXT072B10MM1NSS 530 4 September 2012 Packaged Two-Stage Horizontal Water-to-Air Heat Pumps Roth two-stage vertical water-to-air heatpump: 2 to 5 ton capacity •Compact horizontal cabinet for installation above ceilings or below floors and in crawl spaces •Multiple cabinet configurations choices for installation flexibility •Non-ozone depleting R-410A refrigerant •Coated air coil for extended life span •ECM blower motor •Corrosion proof high impact plastic drain pan •ETL certified to UL & CSA standards, AHRI certified to ISO standards •Copper coaxial heat exchanger, flow switch protected •Auto retry on system fault to eliminate nuisance service calls •High efficiency two-stage Copeland Ultratech scroll compressors •10/5/5 Standard unit warranty: •10 years- Compressor and refrigeration circuit components •5 years- Unit warranty •5 years- Warranty service allowance WATER-TO-AIR HEAT PUMPS - COPPER COIL with DESUPERHEATER Part # Description Tons/ Compatibility 2380003000 Horizontal 2-stage packaged with ECM, copper coil, 2 desuperheater 2380003001 Horizontal 2-stage packaged with ECM, copper coil, 3 desuperheater 2380003002 Horizontal 2-stage packaged with ECM, copper coil, 4 desuperheater 2380003003 Horizontal 2-stage packaged with ECM, copper coil, 5 desuperheater Nomenclature Weight lbs RHT024A11MM1CSS 280 RHT036A11MM1CSS 335 RHT048A11MM1CSS 385 RHT060A11MM1CSS 410 WATER-TO-AIR HEAT PUMPS - COPPER COIL without DESUPERHEATER Part # Description 2380003004 2380003005 2380003006 2380003007 Horizontal 2-stage packaged with ECM, copper coil Horizontal 2-stage packaged with ECM, copper coil Horizontal 2-stage packaged with ECM, copper coil Horizontal 2-stage packaged with ECM, copper coil Geothermal Heat Pump Product Catalog Tons/ Compatibility 2 3 4 5 Nomenclature Weight lbs RHT024A10MM1CSS RHT036A10MM1CSS RHT048A10MM1CSS RHT060A10MM1CSS 280 335 385 410 5 September 2012 WATER-TO-AIR HEAT PUMPS - CURPO NICKEL with DESUPERHEATER Part # Description Tons/ Compatibility 2380003008 Horizontal 2-stage packaged with ECM, curpo nickel, 2 desuperheater 2380003009 Horizontal 2-stage packaged with ECM, curpo nickel, 3 desuperheater 2380003010 Horizontal 2-stage packaged with ECM, curpo nickel, 4 desuperheater 2380003011 Horizontal 2-stage packaged with ECM, curpo nickel, 5 desuperheater Nomenclature Weight lbs RHT024A11MM1NSS 280 RHT036A11MM1NSS 335 RHT048A11MM1NSS 385 RHT060A11MM1NSS 410 WATER-TO-AIR HEAT PUMPS - CUPRO NICKEL without DESUPERHEATER Part # Description 2380003012 2380003013 2380003014 2380003015 Horizontal 2-stage packaged with ECM, cupro nickel Horizontal 2-stage packaged with ECM, cupro nickel Horizontal 2-stage packaged with ECM, cupro nickel Horizontal 2-stage packaged with ECM, cupro nickel Geothermal Heat Pump Product Catalog Tons/ Compatibility 2 3 4 5 Nomenclature Weight lbs RHT024A10MM1NSS RHT036A10MM1NSS RHT048A10MM1NSS RHT060A10MM1NSS 280 335 385 410 6 September 2012 Two-Stage Units Water-to-Water Heat Pumps Roth two-stage water-to-water heat pump: 3 to 10 ton capacity •Powder coated bolted steel cabinet •Non-Ozone depleting R-410A Refrigerant •Removable access panels for easy unit service •ETL certified to UL & CSA standards •AHRI certified to ISO standards •Copper coaxial heat exchangers, flow switch protected •Auto retry on system fault to eliminate nuisance service calls •High efficiency two-stage Copeland Ultratech scroll compressors •10/5/5 Standard unit warranty: •10 years– Compressor and refrigeration circuit components •5 years- Unit warranty •5 years- Warranty service allowance WATER-TO-WATER HEAT PUMPS - COPPER COIL with DESUPERHEATER Part # Description Tons/ Nomenclature Compatibility 2380001001 Water-to-water, copper coil, desuperheater 3 RWT036B11AAACSS 2380001002 Water-to-water, copper coil, desuperheater 4 RWT048B11AAACSS 2380001003 Water-to-water, copper coil, desuperheater 5 RWT060B11AAACSS 2380001005 Water-to-water, copper coil, desuperheater 8 RWT092A11AAACSS* 2380001006 Water-to-water, copper coil, desuperheater 10 RWT120A11AAACSS* Weight lbs 315 345 390 550 670 WATER-TO-WATER HEAT PUMPS WITH COPPER COIL AND without DESUPERHEATER Part # Description 2380001009 2380001010 2380001011 2380001013 2380001014 Water-to-water, copper coil Water-to-water, copper coil Water-to-water, copper coil Water-to-water, copper coil Water-to-water, copper coil Geothermal Heat Pump Product Catalog Tons/ Compatibility 3 4 5 8 10 Nomenclature Weight lbs RWT036B10AAACSS RWT048B10AAACSS RWT060B10AAACSS RWT092A10AAACSS* RWT120A10AAACSS* 315 345 390 550 670 7 September 2012 WATER-TO-WATER HEAT PUMPS - CUPRO NICKEL COIL with DESUPERHEATER Part # Description Water-to-water, cupro nickel coil, desuperheater Tons/ Nomenclature Compatibility RWT036B11AAANSS 3 2380001017 Weight lbs 315 2380001018 Water-to-water, cupro nickel coil, desuperheater 4 RWT048B11AAANSS 345 2380001019 2380001021 2380001022 Water-to-water, cupro nickel coil, desuperheater Water-to-water, cupro nickel coil, desuperheater Water-to-water, cupro nickel coil, desuperheater 5 8 10 RWT060B11AAANSS 390 RWT092A11AAANSS* 550 RWT120A11AAANSS* 670 WATER-TO-WATER HEAT PUMPS - CUPRO NICKEL COIL without DESUPERHEATER Part # Description Weight lbs Water-to-water, cupro nickel coil Tons/ Nomenclature Compatibility RWT036B10AAANSS 3 2380001025 2380001026 2380001027 2380001029 2380001030 Water-to-water, cupro nickel coil Water-to-water, cupro nickel coil Water-to-water, cupro nickel coil Water-to-water, cupro nickel coil 4 5 8 10 345 390 550 670 RWT048B10AAANSS RWT060B10AAANSS RWT092A10AAANSS* RWT120A10AAANSS* 315 *Not Energy Star Rated Geothermal Heat Pump Product Catalog 8 September 2012 Packaged Two-Stage Combination Heat Pumps Roth two-stage vertical water-to-air heatpump: 2 to 6 ton capacity •Unique multi-position cabinet that allows field configuration of left or right return air plenum and upflow or downflow supply air •Combines hydronic heating capability for in-floor radiant heating with forced air\ heating and cooling in a single efficient unit •Non-ozone depleting R-410A refrigerant •High performance micro channel air coil •ECM blower motor •Corrosion proof high impact plastic drain pan •ETL certified to UL&CSA standards, AHRI certified to ISO standards •Copper coaxial heat exchanger, flow switch protected •Auto retry on system fault to eliminate nuisance service calls •High efficiency two-stage Copeland Ultratech scroll compressors •10/5/5 Standard unit warranty: •10 years- Compressor and refrigeration circuit components •5 years- Unit warranty •5 years- Warranty service allowance COMBINATION HEAT PUMPS - COPPER COIL with DESUPERHEATER Part # Description 2380004000 Vertical 2-stage combination with ECM, copper coil, desuperheater 2380004001 Vertical 2-stage combination with ECM, copper coil, desuperheater 2380004002 Vertical 2-stage combination with ECM, copper coil, desuperheater 2380004003 Vertical 2-stage combination with ECM, copper coil, desuperheater Tons/ Nomenclature Weight lbs Compatibility 3 RCT036A11MM1CSS 420 4 RCT048A11MM1CSS 435 5 RCT060A11MM1CSS 535 6 RCT072A11MM1CSS 550 COMBINATION HEAT PUMPS - COPPER COIL without DESUPERHEATER Part # Description 2380004004 2380004005 2380004006 2380004007 Vertical 2-stage combination with ECM, copper coil Vertical 2-stage combination with ECM, copper coil Vertical 2-stage combination with ECM, copper coil Vertical 2-stage combination with ECM, copper coil Geothermal Heat Pump Product Catalog Tons/ Compatibility 3 4 5 6 Nomenclature Weight lbs RCT036A10MM1CSS RCT048A10MM1CSS RCT060A10MM1CSS RCT072A10MM1CSS 420 435 535 550 9 September 2012 COMBINATION HEAT PUMPS - CUPRO NICKEL with DESUPERHEATER Part # Description 2380004008 Vertical 2-stage combination with ECM, cupro nickel, desuperheater Vertical 2-stage combination with ECM, cupro nickel, desuperheater Vertical 2-stage combination with ECM, cupro nickel, desuperheater Vertical 2-stage combination with ECM, cupro nickel, desuperheater 2380004009 2380004010 2380004011 Tons/ Nomenclature Compatibility 3 RCT036A11MM1NSS Weight lbs 4 RCT048A11MM1NSS 435 5 RCT060A11MM1NSS 535 6 RCT072A11MM1NSS 550 420 COMBINATION HEAT PUMPS- CUPRO NICKEL without DESUPERHEATER Part # Description Weight lbs Vertical 2-stage packaged with ECM, cupro nickel Tons/ Nomenclature Compatibility 2 RCT036A10MM1NSS 2380002015 2380002016 2380002017 Vertical 2-stage packaged with ECM, cupro nickel Vertical 2-stage packaged with ECM, cupro nickel 3 4 RCT048A10MM1NSS RCT060A10MM1NSS 435 535 2380002018 Vertical 2-stage packaged with ECM, cupro nickel 5 RCT072A10MM1NSS 550 Geothermal Heat Pump Product Catalog 10 420 September 2012 Two-Stage Split System Heat Pumps - Compressor Section Roth two-stage split system heat pumps: 2 to 6 ton capacity •Enhance the performance of existing heating and cooling systems using geothermal in a dual-fuel configuration •Enhance design flexibility of forced air heating and cooling systems for new construction •Split system compatible with Roth ACD coils and MPD Fan Coil units •Powder coated bolted steel cabinet •Non-ozone depleting R-410A refrigerant •ETL certified to UL&CSA standards, AHRI certified to ISO standards •Copper coaxial heat exchanger, flow switch protected •Auto retry on system fault to eliminate nuisance service calls •High efficiency two-stage Copeland Ultratech scroll compressors •Built-in thermal expansion valve •10/5/5 Standard unit warranty: •10 years- Compressor and refrigeration circuit components •5 years- Unit warranty •5 years- Warranty service allowance SPLIT SYSTEM HEAT PUMPS - COPPER COIL with DESUPERHEATER Part # Description Nomenclature Weight lbs 2380005000 Split 2-stage, copper coil, desuperheater 2380005001 Split 2-stage, copper coil, desuperheater 2380005002 Split 2-stage, copper coil, desuperheater Tons/ Compatibility 2 3 4 RST024A11AAACSS RST036A11AAACSS RST048A11AAACSS 180 225 270 2380005003 Split 2-stage, copper coil, desuperheater 5 RST060A11AAACSS 270 2380005004 Split 2-stage, copper coil, desuperheater 6 RST072A11AAACSS 295 Nomenclature Weight lbs RST024A10AAACSS RST036A10AAACSS RST048A10AAACSS RST060A10AAACSS RST072A10AAACSS 180 225 270 270 295 SPLIT SYSTEM HEAT PUMPS - COPPER COIL without DESUPERHEATER Part # Description 2380005005 2380005006 2380005007 2380005008 2380005009 Split 2-stage, copper coil Split 2-stage, copper coil Split 2-stage, copper coil Split 2-stage, copper coil Split 2-stage, copper coil Geothermal Heat Pump Product Catalog Tons/ Compatibility 2 3 4 5 6 11 September 2012 SPLIT SYSTEM HEAT PUMPS - CUPRO NICKEL with DESUPERHEATER Part # Description Nomenclature Weight lbs 2380005010 Split 2-stage, cupro nickel, desuperheater 2380005011 Split 2-stage, cupro nickel, desuperheater 2380005012 Split 2-stage, cupro nickel, desuperheater Tons/ Compatibility 2 3 4 RST024A11AAANSS RST036A11AAANSS RST048A11AAANSS 180 225 270 2380005013 Split 2-stage, cupro nickel, desuperheater 5 RST060A11AAANSS 270 2380005014 Split 2-stage, cupro nickel, desuperheater 6 RST072A11AAANSS 295 Nomenclature Weight lbs RST024A10AAANSS RST036A10AAANSS RST048A10AAANSS RST060A10AAANSS RST072A10AAANSS 180 225 270 270 295 SPLIT SYSTEM HEAT PUMPS - CUPRO NICKEL without DESUPERHEATER Part # Description 2380005015 2380005016 2380005017 2380005018 2380005019 Split 2-stage, cupro nickel Split 2-stage, cupro nickel Split 2-stage, cupro nickel Split 2-stage, cupro nickel Split 2-stage, cupro nickel Tons/ Compatibility 2 3 4 5 6 DOWNFLOW KITS FOR RXT/RCT UNITS Telescoping duct section with insulation and installation instructions to facilitate the field re-configuration of the Roth RXT/RCT heat pump for downflow supply air orientation. Part # Description Nomenclature Weight lbs (kg) w/ pkg. Downflow kit for 2-3 ton RXT/RCT units Tons/ Compatibility N/A 2380009000 AXDNFL01A Downflow kit for 4-6 ton RXT/RCT units N/A AXDNFL02A 14 (6.5) 14 (6.5) 2380009001 Geothermal Heat Pump Product Catalog 12 September 2012 Two Stage Units Water-to-Water Heat Pumps HYDRONIC A-COILS •For installation on new or existing indoor furnaces for “dual fuel” system configuration •Integral drain pan with primary and secondary drain connections on LH or RH side of pan •Four capacities available 2-5 tons •Coils are ETL and CSA approved Part # Description Nomenclature Uncased Hydronic A-Coil Tons/ Compatibility 2 ACH024ASR Weight lbs (kg) w/ pkg. 38 (17.3) 2380009097 2380009098 Uncased Hydronic A-Coil 3 ACH036ASR 46 (20.9) 2380009099 Uncased Hydronic A-Coil 4 ACH048ASR 48 (21.8) 2380009100 Uncased Hydronic A-Coil 5 ACH060ASR 67 (30.5) HYDRONIC AIR HANDLER •Multi-position air flow pattern, upflow/downflow, horizontal right/left. Field convertible to downflow and horizontal right configuration (downflow kit required for downflow operation). •Single high efficiency copper tube/aluminum “A” coil for heating and cooling, designed for 100 to 120 degree F water temperature in heating mode. •Variable speed G.E. ECM fan motor with multiple speed taps. •Optimized for use with Roth water-to-water heat pumps. •Corrosion-proof plastic drain pan with primary and secondary drain connections. Part # Description Hydronic air handler, multi-position, 115V, 1ph Tons/ Nomenclature Compatibility 2 MPH024A9MM1SR* Weight lbs (kg) w/ pkg. 131 (59.4) 2380009002 2380009003 Hydronic air handler, multi-position, 115V, 1ph 3 MPH036A9MM1SR* 153 (69.4) 2380009004 Hydronic air handler, multi-position, 115V, 1ph 4 MPH048A9MM1SR* 220 (99.8) 2380009005 Hydronic air handler, multi-position, 115V, 1ph 5 MPH060A9MM1SR* 220 (99.8) 2380009006 Hydronic air handler, multi-position, 208-230V, 1ph 2 MPH024A1MM1SR 131 (59.4) 2380009007 Hydronic air handler, multi-position, 208-230V, 1ph 3 MPH036A1MM1SR 153 (69.4) 2380009008 Hydronic air handler, multi-position, 208-230V, 1ph 4 MPH048A1MM1SR 220 (99.8) 2380009009 Hydronic air handler, multi-position, 208-230V, 1ph 5 MPH060A1MM1SR 220 (99.8) *115 models cannot be used with internal backup electric heat (requires 230V model). Geothermal Heat Pump Product Catalog 13 September 2012 Accessories DX SPLIT SYSTEM A-COILS FOR DUAL FUEL APPLICATION •For installation on new or existing indoor furnaces for “dual fuel” system configuration •Integral drain pan with primary and secondary drain connections on LH or RH side of pan •Three capacities available 2-6 tons, sized and tested specifically for the Roth RST system to Energy Star standards •Coils are ETL and CSA approved Part # Description Nomenclature Weight lbs Uncased Hydronic A-Coil Tons/ Compatibility 2 2380009129 ACD024BSR 38 2380009130 Uncased Hydronic A-Coil 3 ACD036BSR 46 2380009131 Uncased Hydronic A-Coil 4-6 ACD060CSR* 67 *RST072 is not Energy Star Rated with ACD060 (only with MPD072)ACD060 (only with MPD072) DX SPLIT SYSTEM AIR HANDLER •Multi-position air flow pattern, upflow/downflow, horizontal right/left. •Fieldconvertible to downflow and horizontal right configuration (down flow kit required for downflow operation). •Single high efficiency copper tube/aluminum “A” coil for heating and cooling, sized and tested specifically for the Roth RST system to Energy Star standards •Variable speed G.E. ECM fan motor with multiple speed taps. •Corrosion-proof plastic drain pan with primary and secondary drain connections. Part # Description DX fan coil, multi-position, 208-230V, 1ph* Tons/ Nomenclature Compatibility 2 MPD024A1MM1SR Weight lbs (kg) w/ pkg. 131 (59.4) 2380009132 2380009133 DX fan coil, multi-position, 208-230V, 1ph* 3 MPD036A1MM1SR 153 (69.4) 2380009134 DX fan coil, multi-position, 208-230V, 1ph* 4&5 MPD060A1MM1SR 220 (99.8) 2380009135 DX fan coil, multi-position, 208-230V, 1ph* 6 MPD072A1MM1SR 220 (99.8) *Downflow kit required for downflow application. Geothermal Heat Pump Product Catalog 14 September 2012 Accessories FIELD-INSTALLED EXTERNAL ELECTRIC (DUCT) HEATERS (RHT) Part # Description 5kW Internal Electric Heater Tons/ Nomenclature Compatibility RHT024 AXHS051A 2380009136 Weight lbs 25 2380009137 10kW Internal Electric Heater RHT024 AXHS101A 40 2380009138 10kW Internal Electric Heater RHT036 AXHM101A 40 2380009139 15kW Internal Electric Heater RHT036 AXHM151A 55 2380009140 15kW Internal Electric Heater RHT048-060 AXHL151A 55 2380009141 20kW Internal Electric Heater RHT048-060 AXHL201A 57 THERMOSTATS •Programmable •Touchscreen interface •3 heating stages, 2 cooling stages, auto mode changeover •5/1/1 day or 7 day programs •Cool Savings™ feature auto-adjusts set value in cool mode. •Non Programmable •3 heating stages, 2 cooling stages •Auto mode changeover •Cool Savings ™ feature auto-adjusts set value in cool mode Part # Description Nomenclature 2380009012 Digital, programmable thermostat with touchscreen (3 heat/2 cool) Indoor remote sensor Tons/ Compatibility All water-toair units All water-toair units ATRPE32A 2380009010 Digital, non-programmable thermostat (3 heat/2 cool) 2380009011 1F83-0471 Weight lbs (kg) w/ pkg. 1 (.5) 1F95-1291 1 (.5) ATEISA 1 (.5) 2380009013 Outdoor remote sensor ATRPE32A ATSPIOA 1 (.5) FIELD-INSTALLED INTERNAL ELECTRIC HEATERS (RXT/RCT SERIES) •Modular electric grid heater provides auxiliary heating to supplement Heat Pump output in heating mode. •Unit installs in the RXT fan plenum, integral time delay relay included. Part # Description 2380009014 10kW internal plenum heater RXT024-072 and RCT024-072 AHTR101B Weight lbs (kg) w/ pkg. 9.5 (4.3) 2380009015 15kW internal plenum heater RXT048-072 and RCT048-072 AHTR151B 11.5 (5.2) 2380009016 20kW internal plenum heater RXT048-072 and RCT048-072 AHTR201B 12 (5.4) Geothermal Heat Pump Product Catalog Tons/Compatibility Nomenclature 15 September 2012 Accessories FIELD-INSTALLED INTERNAL ELECTRIC HEATERS (HYDRONIC AIR HANDLER) •Modular electric grid heater provides auxiliary heating to supplement fancoil output in heating mode. •Compatible with 230V Fan Coil units only. Part # Description Tons/ Compatibility Nomenclature Weight lbs (kg) w/ pkg. 2380009017 10kW Internal Electric Heater AHM101S 7 (3.2) 2380009018 10kW Internal Electric Heater AHM101M 7 (3.2) 2380009019 10kW Internal Electric Heater AHM101L 7 (3.2) 2380009020 15kW Internal Electric Heater AHM151L 8 (3.6) 2380009021 20kW Internal Electric Heater MPH/MPD024 -- 230V only MPH/MPD036 -- 230V only MPH/MPD048060 -- 230V only MPH/MPD048060 -- 230V only MPH/MPD048060 -- 230V only AHM201L 9 (4.1) AIR PADS •Available in molded high density plastic, polyethylene foam, or modular blocks. •Provides even support for the Heat Pump unit and vibration isolation. •RXT down flow configuration requires cutable air pad. Part # Description Tons/Compatibility Nomenclature 2380009142 24” x 36” x 2” high density plastic pad RST024 AP2436P Weight lbs (kg) w/ pkg. 15 (6.8) 2380009022 33" x 33" x 2" high density plastic pad RXT/RCT024-072, RST036-072 AP3333P 15 (6.8) 2380009023 24” x 32” x 2” polyethylene foam pad (Cutable) AP2432F 3 (1.36) 2380009024 30” x 36” x 2” polyethylene foam pad (Cutable) AP3036F 3 (1.36) 2380009143 36” x 48” x 2” high density plastic pad RWT092-120 AP3648P 15 (6.8) 2380009025 34” x 50” x 3” polyethylene foam pad RWT092-120 AP3450F 6 (2.7) 2380009026 30” x 36” x 3” modular block pad Modular AP3036P3 15 (6.8) Geothermal Heat Pump Product Catalog 16 September 2012 Accessories FLOW CENTERS - PRESSURIZED • Self-contained ground loop flow station •Includes insulated housing, Grundfos pump(s), fill and purge connections for the ground loop. •Also included are 1-1/4” Fusion x 1” double o-ring fittings (AGA6PES) for flow center connection to the HDPE ground loop. •Hose kits are required to connect flow center to the heat pump and are found and described in the Hose Kit section of this catalog. Part # Description 2380009101 Pressure Battery Expansion Tank 2380009102 Geo-Prime Reservoir Tank (creates non pressurized system with pressurized flow centers) 2380009027 Single Pump - Brass Valve UP26-116U-230V - Double O-Ring Fittings Double Pump - Brass Valve UP26-116U-230V - Double O-Ring Fittings Single Pump - Brass Valve UP26-99F-230V - 1” FPT 2380009028 2380009029 2380009030 Double Pump - Brass Valve UP26-99F-230V - 1” FPT 2380009103 Single Pump - Brass Valve UP26-99-230V - Double O-Ring Fittings 2380009104 Double Pump - Brass Valve UP26-99-230V - Double O-Ring Fittings 2380009031 Three Pump - Brass Valve UP26-99F-230V - 1” FPT 2380009032 Four Pump - Brass Valve UP26-99F-230V - 1”FPT 2380009033 Loop Pump Sharing Module (for using one flow center for 2 units) Geothermal Heat Pump Product Catalog Tons/ Compatibility AGFC Flow Centers AGFC Double O-ring pressurized flow centers Check pressure drop(normally 1.5 to 4 tons) Check pressure drop(normally 5 to 7 tons) Check pressure drop(normally 1.5 to 4 tons) Check pressure drop(normally 3.5 to 6 tons) Nomenclature APBTA Weight lbs (kg) w/ pkg. 5 (2.3) AGPTA 13 (5.9) AGFC1A 32 (14.5) AGFC2A 37 (16.8) AGFC1B 37 (16.8) AGFC2B 42 (19.1) Check pressure drop(normally 1.5 to 4 tons) Check pressure drop(normally 5 to 7 tons) Check pressure drop(normally 6 to 9 tons) Check pressure drop(usually 7 to 10 tons) All AGFC1D 24 (10.9) AGFC2D 30 (13.6) AGFC3E 55 (24.9) AGFC4E 60 (27.2) APSMA 1 (.5) 17 September 2012 Accessories FLOW CENTERS - NON-PRESSURIZED •B&D QT model insulated flow station •Single and multiple pump configurations available •Air separation chamber- continuous purge function •Removable lid •Easy to monitor fluid volume and flow rate •No purge cart required if valved indoor headers are used. Part # 2380009102 2380009106 2380009107 2380009108 2380009109 2380009110 Description Tons/ Compatibility Geo-Prime Reservoir Tank AGFC Double (creates non-pressurized system with O-ring Pressurized pressurized flow centers) Flow Centers Single Pump QT Series Module -UP26- Check pressure 99F-230V - 1” FPT drop(normally 1.5 to 3 tons) Single Pump QT Series Module -UP26- Check pressure 116F-230V - 1” FPT drop(normally 1.5 to 3 tons) Double Pump QT Series Module -UP26- Check pressure 99F-230V - 1” FPT drop(normally 3.5 to 6 tons) Double Pump QT Series Module -UP26- Check pressure 116F-230V - 1” FPT drop(normally 3.5 to 6 tons) Four Pump QT Series Module -UP26Check pressure 99F-230V - 1” FPT drop(usually 7 to 10 tons) Geothermal Heat Pump Product Catalog Nomenclature AGPTA Weight lbs (kg) w/ pkg. 13 (5.9) ABFC1A 41 (18.6) ABFC1B 41 (18.6) ABFC2A 50 (22.7) ABFC2B 50 (22.7) ABFC4A 150 (68.2) 18 September 2012 Accessories REPLACEMENT PUMPS • Replacement Grundfos pumps for pressurized and non-pressurized flow centers, 230V. Part # Description Tons/Compatibility Nomenclature 2380009034 UP26-116F-230V Replacement Pump Pressurized flow center AGPA1 Weight lbs (kg) w/ pkg. 11 (5) 2380009035 UP26-99F-230V Replacement Pump Pressurized flow center AGPA2 11 (5) 2380009111 UP26-99F-230V Replacement Pump ABPA1 11 (5) 2380009112 UP26-116F-230V Replacement Pump Non-pressurized flow center Non-pressurized flow center ABPA2 11 (5) HOSE KITS • Complete 10’ hose kit required for connecting the Heat Pump to the pressurized flow station connections. •Includes hose clamps, pressure and temperature test fittings, male NPT fittings for the source connections on the unit and fittings for the flow station connections as specified in the product descriptions below. Part # Description Tons/Compatibility Nomenclature 2380009036 Hose Kit: 10’ 1” rubber hose, hose clamps, (2)1/4” P/T fittings, (2) 1" MPT x 1" insert w/P/Tports, (2) double o-ring x 1” hose barb fittings Hose Kit: 10’ 1” rubber hose, hose clamps, (2)1/4” P/T fittings, (2) 1” MPT x 1” insert w/P/T ports, (2)AGBA55 1” MPT x 1” barb fittings All units* with AGFC_A series flow centers AGHK5A Weight lbs (kg) w/ pkg. 9.5 (4.3) All units* withAGFC_B and ABFC_A series flow centers AGHK5B 9.5 (4.3) 2380009037 *Except RWT092-120 Geothermal Heat Pump Product Catalog 19 September 2012 Accessories CLOSED LOOP ADAPTER FITTINGS Part # Description Nomenclature Double O-Ring x 1” Brass Insert (Set of 2) Tons/ Compatibility AGFC_A series AGA5INS Weight lbs (kg) w/ pkg. 1.55 (.7) 2380009039 2380009040 Double O-Ring x 1.25” Brass Insert (Set of 2) AGFC_A series AGA6INS 1.55 (.7) 2380009041 Double O-Ring x 1” Brass MPT (Set of 2) AGFC_A series AGA5MPT 1.55 (.7) 2380009042 Double O-Ring x 1” PE Socket (Set of 2) AGFC_A series AGA5PES .55 (.25) 2380009043 Double O-Ring x 1.25” PE Socket (Set of 2) AGFC_A series AGA6PES .55 (.25) 2380009113 Double O-ring x 1.25" PVC Glue (Set of 2) AGFC_A series AGPVC6 1 (.5) 2380009044 Double O-Ring x Cam Lever Male Elbow (Set of 2) Double O-Ring x 1” (FPT) (Set of 2) AGFC_A series AGAFP .7 (.3) AGFC_A series AGA5FPT 1.55 (.7) Double O-Ring x Garden Hose Male Fitting AGFC_A series to use when replacing a pump to avoid using a flush cart (Set of 2) Double O-Ring x Garden Hose Female Fitting AGFC_A series to use when replacing a pump to avoid using aflush cart (Set of 2) 1” MPT x 1” Barbed Brass Adaptor ABFC_A & AGFC_B series 1” MPT x 1.25” Barbed Brass Adaptor ABFC_A & AGFC_B series 1.25” PE Fusion x 1” Brass MPT ABFC_A & AGFC_B series 1” Rubber Hose (per foot) Hose kits AGAMGH .5 (.2) AGAFGH .5 (.2) AGBA55 .6 (.3) AGBA56* 1 (.5) GFMA65* .6 (.3) AGH5A 2 (.9) AGFC_A series AGO5INS 1.7 (.8) AGFC_A series AGO5MPT 1.55 (.7) 2380009054 Double O-Ring x 1” Hose Barb El w/PT Tap (Set of 2) Double O-Ring x 1” MPT Elbow w/PT Tap (Set of 2) 1” Check Valve (Threaded) Parallel pumping ASCV5A 1 (.5) 2380009055 3-Way Valve Kit AGFVK 2 (.9) APDFV 69.5 (31.5) SNC45 SNC55 .5 (.17) .5 (.17) 2380009045 2380009046 2380009047 2380009048 2380009049 2380009050 2380009051 2380009052 2380009053 2380009056 2380009038 2380009116 Non-press with inside header 1.25” PE Double Flush Valve Non-press with inside header Hose Kit Adapter - 3/4" FPT x 1" female swivel RHT024-036** Hose Kit Adapter - 1" FPT x 1" female swivel All except RWT092-120 *Either/Or required if using ABFC_A, AGFC_B **RHT024-036 have 3/4” FPT fittings. SNC45 converts to 1” for use with hose kits. Geothermal Heat Pump Product Catalog 20 September 2012 Accessories OPEN LOOP (WELL WATER) ACCESSORIES Part # Description Nomenclature 1” Plastic Solenoid Valve, Threaded Tons/ Compatibility Up to 6 tons APV5A Weight lbs (kg) w/ pkg. 1 (.5) 2380009057 2380009058 1" Brass Solenoid Valve, 24V, Threaded Up to 6 tons ABV5A 3 (1.4) 2380009059 Solenoid Valve Replacement Coil, 24V APV5A ABVCA 1 (.5) 2380009060 AMV4 2 (.9) AMV5 2 (.9) 2380009062 Taco Zone Valve 0.75” FPT - 24VAC coil with 22VA Up to 5 GPM draw Taco Zone Valve 1” SWT - 24VAC coil with 22VA Up to 10 GPM draw Taco Zone Valve Power Head Replacement AVM valves AMV-PH 1 (.5) 2380009063 Honeywell Solenoid Valve Actuator AVAHA 2 (.9) 2380009064 Honeywell Solenoid Valve Brass Body - .75” AVB4HA & AVB5HA AVAHA AVB4HA 2 (.9) 2380009065 Honeywell Solenoid Valve Brass Body - 1” AVAHA AVB5HA 2 (.9) 2380009144 Taco Electr. Ball Valve 0.75” FPT Up to 5 GPM ATEBV4A 2380009145 Taco Electr. Ball Valve 1” FPT Up to 10 GPM ATEBV5A 2380009146 Replacement Actuator ATEBV4A, 5A ATEBVAA 2380009066 See spec catalog for flow rate See spec catalog for flow rate See spec catalog for flow rate See spec catalog for flow rate See spec catalog for flow rate See spec catalog for flow rate See spec catalog for flow rate See spec catalog for flow rate See spec catalog for flow rate All All AFR2 1 (.5) AFR3 1 (.5) AFR4 1 (.5) AFR5 1 (.5) AFR6 1 (.5) AFR7 1 (.5) AFR8 1 (.5) AFR9 1 (.5) AFR10 1 (.5) 2380009075 2380009076 Flow Restrictor Fittings 0.75” x 0.75” FPT -2 GPM Flow Restrictor Fitting 0.75” x 0.75” FPT -3 GPM Flow Restrictor Fitting 0.75” x 0.75” FPT -4 GPM Flow Restrictor Fitting 0.75” x 0.75” FPT -5 GPM Flow Restrictor Fitting 0.75” x 0.75” FPT -6 GPM Flow Restrictor Fitting 0.75” x 0.75” FPT -7 GPM Flow Restrictor Fitting 0.75” x 0.75” FPT -8 GPM Flow Restrictor Fitting 0.75” x 0.75” FPT -9 GPM Flow Restrictor Fitting 0.75” x 0.75” FPT -- 10 GPM 0.25” MPT Brass PT Plug 0.50” MPT Brass PT Plug AGPT2A AGPT3A 2 (.9) 2 (.9) 2380009077 Stainless Steel Flow Meter -- 1 to 10 GPM AFM10A 1 (.5) 2380009078 Stainless Steel Flow Meter -- 1 to 17 GPM Refer to spec catalog Refer to spec catalog AFM12A 1 (.5) 2380009061 2380009067 2380009068 2380009069 2380009070 2380009071 2380009072 2380009073 2380009074 Geothermal Heat Pump Product Catalog 21 September 2012 Accessories REPLACEMENT/OPTIONAL FILTERS • Filters- Conventional paper pleat type filter cartridge, available in case quntities. •Electrostatic Filter- Self charging multi-layer filter, washable. Fits into existing filter tracks on the RXT Heat Pump. •Dynamic Air Cleaner- Electronic polarized media filter. This unit includes an activated charcoal screen and an active electrostatic field. External 24VDC power required. •Replacement media packaged in quantity of three each. Fits into existing filter tracks on the RXT Heat Pump. Part # Description Tons/Compatibility Nomenclature 2380009086 28” x 30” x 1” Pleated Air Filter, case of 12 (RXT024 – 036) APAF2830A Weight lbs (kg) w/ pkg. 1.7 (.77) 2380009087 28” x 34” x 1” Pleated Air Filter, case of 12 (RXT048 – 072) APAF2834A 1.75 (.8) 2380009088 28” x 30” x 1” Electrostatic Air Filter (RXT024- 036) AEF2830A 8 (3.6) 2380009089 28” x 34” x 1” Electrostatic Air Filter (RXT048- 072) AEF2834A 8 (3.6) 2380009090 28” x 30” x 1” Dynamic Electronic Air Cleaner (RXT024-036) AEAC2830 7.3 (3.3) 2380009091 28” x 34” x 1” Dynamic Electronic Air Cleaner (RXT048-072) AEAC2834 7.8 (3.5) 2380009092 Replacement Media (3 Pack) for AEAC2830 ACRM2830 10 (3.18) 2380009093 Replacement Media (3 Pack) for AEAC2834 ACRM2834 10 (3.18) FILTER RACK (HYDRONIC AIR HANDLERS ONLY) Part # Description Tons/Compatibility Nomenclature 2380009094 Small Filter Rack MPH/MPD024 AMPFILTERS Weight lbs (kg) w/ pkg. 6 (2.7) 2380009095 Medium Filter Rack MPH/MPD036 AMPFILTERM 7 (3.2) 2380009096 2380009152 2380009153 2380009154 Large Filter Rack Small Downflow Kit (MPD only) Medium Downflow Kit (MPD only) Large Downflow Kit (MPD only) MPH/MPD048-072 MPD024 MPD036 MPD060-072 AMPFILTERL AMPDNWFLWS AMPDNWFLWM AMPDNWFLWL 8 (3.6) Geothermal Heat Pump Product Catalog 22 September 2012 Accessories MISC. INSTALLATION ACCESSORIES Part # Description Tons/Compatibility Nomenclature 2380009079 0.5” Check Valve (Sweat) ACV3A 2380009080 0.75” Check Valve (Sweat) ACV4A 1 (.5) 2380009081 EZ-Trap 0.75” Kit Desuperheater Installation Desuperheater Installation 2-3 ton water-to-air Weight lbs (kg) w/ pkg. 1 (.5) ACDT1A 1 (.5) 2380009147 EZ-Trap 1” Kit 4-6 ton water-to-air ACDT2A 2380009082 Hard Start Kit 1.5 to 3 ton units ASK1A 1 (.5) 2380009083 Hard Start Kit 3.5 to 6 ton units ASK2A 1 (.5) 2380009148 Soft Start Kit RST/RWT024-036 AKSSSB 1 (.5) 2380009149 Soft Start Kit RST/RWT048-072 AKSSLB 1 (.5) 2380009150 Soft Start Kit RXT/RCT024-036 AKSSSC 1 (.5) 2380009151 Soft Start Kit RXT/RCT048-072 AKSSLC 1 (.5) SOFTWARE •Loop sizing and pressure drop calculations •Unit sizing with bin data report options •Flow center pump selection and curve reports •Economic comparison Geo vs Fossil fuel systems and payback period •Proposal package •Based directly on IGSHPA loop and system sizing algorithms Part # Description 2380010000 Geoanalyst- Geothermal Heat Pump Sizing and Selection Software Geothermal Heat Pump Product Catalog Tons/ Compatibility N/A Nomenclature 1 (.5) 23 September 2012 Other Roth Product Catalogs Available Include: Solar Product Catalog PEX-c Plumbing Product Catalog Double-Wall Oil Storage Tanks Hydronic and Radiant Product Catalog Call 1.888.266.7684 or visit www.roth-america.com for additional information. Roth, a family-owned business established in Germany over 60 years ago, now operates in over 40 countries worldwide with $250 million in sales and 1,100 employees. The North American division operates two manufacturing plants in upstate New York. Roth specializes in environmentally-friendly products that produce, distribute and store energy for the finest homes. ENERGY PRODUCTION: Solar and Heat Pump Systems Energy Storage: Septic, Cistern, Rainwater Collection and Oil Storage Tanks Energy Distribution: Radiant Floor Heating and Pex-c Plumbing Systems Roth Industries, Inc. North American Corporate Office P.O. Box 245, Syracuse, NY 13211 Toll Free US: 888.266.7684 CAN: 800.969.7684 September 2012 P: 315.755.1011 F: 315.755.1013 info@roth-usa.com service@roth-canada.com www.roth-america.com
Similar documents
Engineering Data and Installation Manual
* For the source water loop, GeoComfort residential models use 1” double o-ring fittings. GeoComfort commercial, Hydron Module & TETCO models use 1” FPT fittings.
More informationEngineering Data and Installation Manual
Section 4: Installation Unit Placement, Pre-Installation Checklist....................................................................................8 Unit Dimensional Data...........................
More information