Thermo Scientific Hamilton Air Flow Products
Transcription
Thermo Scientific Hamilton Air Flow Products
Thermo Scientific Hamilton Air Flow Products Table of Contents Fume Hood Technology and Terms.................................................................................4-11 Operating Instructions..........................................................................................................12 Ordering Information.......................................................................................................14-15 Fume Hood and Exhaust Unit Selections ....................................................................16-87 SafeAire Fume Hood .......................................................................................................16-47 Concept Fume Hood ........................................................................................................49-60 Pioneer Fume Hood .........................................................................................................61-63 Advantage Fume Hood ...................................................................................................64-65 Infinity Filtered Fume Hood ............................................................................................66-69 Horizon Fume Hood .........................................................................................................70-72 PaceAire Fume Hood............................................................................................................74 Table Top Fume Hood......................................................................................................75-76 Canopy Fume Hood ...............................................................................................................76 Articulated Exhaust Fume Hood .........................................................................................77 Forensic Exhausted Cabinets ........................................................................................78-79 Chemical Storage Cabinet ...................................................................................................80 captair Flex Ductless Fume Hood .................................................................................81-82 Biological Safety Cabinets .............................................................................................84-87 Remote and Front Loaded Valves and Fixtures ..........................................................88-95 Fume Hood Monitors/Alarms ..............................................................................................96 Work Surfaces, Cupsinks and Traps ..........................................................................97-103 Base Cabinets: Solvent, Acid Storage and Trays ..................................................105-109 Enclosure and Filler Panels For Fume Hood and Cabinets ..................................110-118 Electrical, Variacs Pressure Gauges and Lattice Racks ......................................119-122 Fire Extinguishers, Safety Labels and Auxiliary Air Conversion Packages ..............123 Exhaust Components, Blowers and Technical Information .................................124-138 Rough-in Details for all Fume Hood..........................................................................139-150 Technical Fume Hood Specifications.......................................................................151-153 Index (by part number) ...............................................................................................154-161 Dimension are nominal and illustrations and specifications are based on the latest product information available at the time of publication. The right is reserved to make changes at any time without notice. 3 Thermo Scientific Hamilton Air Flow Products Fume Hood Technology How a Fume Hood Works The complexities of fume hood operation become apparent when the many variables involved in exhausting fumes generated in the space are considered. An adequate ”pull” of air, known as face velocity is required to move fumes from the fume hood through the ductwork. Face velocity is measured in feet per minute (FPM) at the vertical sash plane. In order to maintain consistent face velocity, a certain quantity of air, or exhaust volume, is required. Exhaust volume is measured in cubic feet per minute (CFM). Sash position also impacts face velocity. The sash is a transparent panel set in the fume hood face. Airflow patterns into the fume hood are influenced by the air foil. Located just beneath the sash, the air foil decreases turbulence of air entering the fume hood. Some fume hood feature air foils on the left and right sides of the sash as well. Sash Baffles Air Foil Fume Hood with Air Foil Fume Hood Without Air Foil These diagrams illustrate how an air foil can reduce the turbulence of air entering a fume hood, thus improving fume hood containment. 4 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Fume Hood Technology How a Fume Hood Works (continued) Located across the inside rear of the fume hood, baffles control airflow patterns through the fume hood. Baffle panels are located in a position determined to be most effective for the application. A remote adjustment option allows the user to reposition the baffles according to characteristics of effluents generated in the fume hood. Remote baffle adjustment located on the outside of the fume hood corner post complies with OSHA Lab Standard recommendations. Baffle Positions For lighter-than-air gases and high heat generation, maximum airflow is provided at the top of the fume hood. The top slot is adjusted to wide open, center and side slots remain at normal position, and the bottom slot is reduced. For heavier-than-air gases and fumes generated at the work surface, maximum air flow is provided at the bottom of the fume hood, near the work surface. The top slot is closed, and the center, side and bottom slots are open. Concept and Pioneer fume hood only have a fixed baffle for lower face velocity applications. Sash Positions Sash operating position while work is being performed in the fume hood is a maximum 18” opening for vertical rising sashes. Sash setup position is defined as an opening greater than the operating position for loading materials with which to perform work. Work should not be performed in the setup position. 5 Thermo Scientific Hamilton Air Flow Products Fume Hood Technology Fume Hood Exhaust Systems Two types of fume hood exhaust systems are constant volume (CV) and variable air volume (VAV). Either system can be used with individual or manifold duct and blower configurations (see page 8). The fume hood exhaust system must be compatible with the room’s HVAC system. The type of fume hood and related exhaust system will depend on the building’s HVAC system, the number of fume hood in the lab, and any special or unique requirements. Consult with the Thermo Fisher Scientific representative, Facilities Manager and/or HVAC contractor. Constant Volume Exhaust Systems Constant volume fume hood maintain consistent exhaust volume regardless of sash position. Face velocity varies as the sash is moved. Three types of fume hood can provide constant volume function: Bypass, Auxiliary Air, and Restricted Bypass. Bypass Fume Hood with Constant Volume Exhaust Systems Incorporating a bypass, or additional source of exhaust air when the sash is lowered, is one way to keep face velocities within an acceptable range while maintaining a balance between the room ventilating system and fume hood exhaust volume. Constant volume fume hood are equipped with a bypass located above the sash which open as the sash is lowered thereby allowing additional air to enter the fume hood. Thermo Scientific Hamilton fume hood also feature a lower bypass located below the bottom air foil sill which continuously purges the work surface area. The face velocity will increase as the sash is lowered. The bypass acts as a relief to limit the increase in face velocity. This negates adverse effects on papers, powders or flames inside the fume hood. A Constant Volume Bypass fume hood shown first with the sash in the operating position and room air entering from the sash opening, then with the sash closed and room air entering through the louvered and lower bypass openings. Auxiliary Air Fume Hood with Constant Volume Exhaust Systems When there is insufficient room air to supply the fume hood’s exhaust volume requirements, an auxiliary air fume hood may be recommended. Air is brought in from the outside, heated to room temperature in winter, or cooled to room temperature +20° in summer, then supplied to the fume hood. (Thermo Scientific Hamilton fume hood will reach over 95% efficiency in controlling and capturing the supply air when its temperature falls in the ”room air to +20°F” range.) When the sash is raised, auxiliary air is directed to the fume hood face. When the sash is lowered, auxiliary air enters the fume hood from above. An Auxiliary Air fume hood shown first with the sash in operating position and auxiliary air entering from the sash opening, then with the sash closed and auxiliary air entering directly into the fume hood compartment. 6 Operating with 50 to 70% auxiliary supply air, these fume hood use significantly less room air, which can result in energy savings. However, supply air temperature and moisture content should be carefully controlled to manage containment effects on work performed in the fume hood. Undesirable turbulence at the fume hood face can be minimized by careful balancing of the fume hood with the room ventilation system. www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Fume Hood Technology Restricted Bypass Fume Hood with Constant Volume Exhaust Systems Constant volume operation can be achieved when Restricted Bypass fume hood are equipped with ”face opening reducing devices” and when the exhaust system is sized to maintain operational exhaust volume and face velocity at the reduced opening. Face opening reducing devices used with restricted bypass fume hood designs include horizontal sashes, combination sashes, and postless sashes. (See page 15.) These modified sash designs can reduce exhaust volumes by as much as 30% to 60%. This reduced exhaust volume enables the bypass to be reduced thus achieving constant volume operation without excessive face velocity increases. A Restricted Bypass fume hood shown first with sash in the operating position and air entering through the sash opening, then with sash closed and very little air entering the fume hood compartment. Variable Air Volume (VAV) Exhaust Systems VAV systems maintain constant face velocities by varying exhaust volume in response to changes in sash position. Maximum air is exhausted when the sash is open; minimum air is exhausted when the sash is closed. A minimum flow of 25 CFM per square foot of interior work space, as stated by NFPA, should be maintained to achieve optimum containment and satisfactory dilution with the sash closed. Restricted Bypass Fume Hood with VAV Exhaust Systems All VAV systems should be used with a restricted bypass fume hood. Since only the amount of air needed to maintain the specified face velocity is pulled from the room, significant energy savings can be realized when the sash is in a closed position. Either vertical or horizontal sash configurations can be used effectively in VAV applications. Important: Correlate multiple VAV fume hood controllers with room air supply units so that sufficient air volume is available for every fume hood and room pressure is maintained. A Variable Air Volume (VAV) system with restricted bypass, shown first with sash in the operating position and damper fully open, then with sash closed and damper allowing minimal exhaust. 7 Thermo Scientific Hamilton Air Flow Products Fume Hood Technology Typical Fume Hood Duct & Blower Configurations Both manifold and individual configurations can be used with either constant volume or variable air volume exhaust systems. Manifold System Manifold systems are popular for multiple-fume hood applications. Each fume hood’s exhaust is pulled into the exhaust duct plenum and removed by a centralized blower. Manifold systems cost less to install than individual fume hood/blower systems because they share a common blower and duct system. However, it is extremely important that adequate makeup air is available for each fume hood (regardless of the number of fume hood in operation at any given time) and that the total room HVAC system is properly balanced. Roof-mounted Blower Exhaust Duct Plenum Damper Shaded areas are specified, bid and installed as part of the Mechanical Contract. Shaded areas are specified, bid and installed as part of the Mechanical Contract. Individual System This is the simplest approach to exhausting a fume hood. This configuration can be used with single and multiple fume hood installations. Although installation and material costs are higher with individual blower systems, they are easier to balance, and failure of one blower will not affect use of remaining fume hood systems. 8 Ro om Ce ilin g Lin e Important: n Perchloric Acid fume hood should not be connected to a manifold system. n Both Individual and Manifold configurations can be designed for constant volume or variable air volume (VAV) systems. www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Fume Hood Technology Face Velocity, Exhaust Volume, and Static Pressure Face velocity, exhaust volume, and static pressure are critical parameters in fume hood performance, functioning in unison with the room’s HVAC design. Published Face Velocity Guidelines Determining Exhaust Volume The appropriate face velocity will vary depending on usage of the fume hood and the way in which the fume hood has been set up. There are several published guidelines that indicate general ranges for face velocity settings. Additional state and local guidelines for face velocity may exist. In order to calculate exhaust volume, fume hood type, size and the number of air changes per hour for the lab are required. (Consult with an HVAC professional or mechanical engineer.) To determine the quantity of room air available for fume hood exhaust (in CFM), use the following equation: Organization Reference Face Velocity OSHA 29 CFR 1910 • 1450 60-100 FPM ACGIH Industrial Ventilation Manual 23rd Edition, 60-100 FPM To determine exhaust volume for a particular fume hood, use the following equation: ANSI/AIHA Z9.5, 2003 80-120 FPM Exhaust Volume (CFM) = Face velocity (FPM) x fume hood opening (ft2) NFPA NFPA 45, 2000 80-120 FPM SEFA SEFA 1, 2006 60-100 FPM Consult with a planner for the appropriate face velocity for the fume hood selected, taking into account fume hood setup processes and the specific application. Under typical operating conditions, Thermo Scientific Hamilton fume hood most reliably provide containment at the levels specified by applicable industry standards when operated at a 100 feet per minute face velocity. For other Thermo Scientific Hamilton fume hood, please refer to the appropriate product specifications and consult with a lab planner to determine an appropriate face velocity for each specific application. Exhaust volume (CFM) = Room size (cubic feet) x [room changes per hour ÷ 60] Minor discrepancies can be resolved by adjusting fume hood exhaust volume or the amount of air delivered to the room. Choosing an alternative fume hood style or sash configuration may be the only way to reconcile major differences. As part of the balance contract at installation, a duct traverse should be performed to determine proper fume hood volume. Static Pressure Static pressure is the resistance created as air moves through a fume hood. Sometimes referred to as static pressure loss, it is measured in inches of water. Fume hood operate more efficiently and with less noise at lower static pressure values. A low fume hood static pressure rating indicates that the fume hood is offering minimal resistance to air flow, resulting in reduced noise and requiring a smaller exhaust fan. A few fume hood design characteristics that also affect static pressure include: n Larger baffle slots make it easier for air to move through the fume hood n A larger exhaust outlet enables more air to pass through at lower velocity n A tapered exhaust collar reduces turbulence n Together, the correct exhaust collar and baffle configuration will reduce fume hood static pressure The static pressure rating of the fume hood is very important to correct sizing of the blower system and should be provided to the HVAC contractor to ensure a properly sized exhaust system. 9 Thermo Scientific Hamilton Air Flow Products Fume Hood Technology Glossary ACGIH – American Conference of Governmental Industrial Hygienists ADA – Americans with Disabilities Act Air Foil – Shaped or streamlined member at fume hood entrance designed to enhance movement of air into the fume hood Air Volume – Rate of air flow, normally expressed in cubic feet per minute (CFM) ASHRAE – American Society of Heating, Refrigerating and Air Conditioning Engineers, a professional group that sets industryaccepted standards for fume hood testing procedures Face Velocity – Speed of air moving into the fume hood through the face opening (through the sash), measured in feet per minute (FPM) Floor-mounted – Tall or full-height type of fume hood, designed for large or tall apparatus FPM – Feet Per Minute; measurement of air velocity Fume Hood – Five-sided ventilated enclosure used in laboratories to collect and exhaust contaminants Fume Hood Diversity – See Diversity Liner – Fume hood interior sides, back and top, including baffle Auxiliary Air – Supply or make-up air delivered external to the chamber of a fume hood to reduce air consumption Lintel – Portion of fume hood front located above access opening Baffle – Panels located across back of fume hood interior which control pattern of air moving through the fume hood Louvers – Slit-like openings in the lintel that allow bypass air to enter the fume hood when the sash is closed Bench – Type of fume hood designed to rest atop a counter or base cabinet LPM – Liters Per Minute; Metric measurement of air volume Blower – Air-moving device (or fan) consisting of motor, impeller and scroll Magnehelic – Type of gauge suitable for measuring very low air pressures Manometer – Device used to measure air pressure differential Bypass – Compensating opening that helps maintain constant volume exhaust from fume hood, regardless of sash position Makeup Air – Free or available air needed to permit fume hood to develop face velocity Canopy Fume Hood – Ceiling-suspended ventilating device for noncritical use with heat, water vapor, odors, etc. MPM – Meters Per Minute; Metric measurement for air velocity CFM – Cubic feet per minute; unit of air volume measurement Combination Sash – Horizontal panels in a vertically rising frame; see Sash Constant Volume – Type of fume hood exhaust system that exhausts the same volume of air, regardless of sash position Containment – Extent to which fumes are confined within the fume hood compartment Damper – Device installed in duct to control air flow volume Demonstration Fume Hood – Fume hood accessible from front and back sides used for demonstration purposes NFPA – National Fire Protection Association Negative Pressure – Pressures lower than one atmosphere Plenum Chamber – Chamber or enclosure where air moves at reduced velocity and has different pressure from balance of system or atmosphere Positive Pressure – Pressures higher than one atmosphere Restricted Bypass Fume Hood – Fume hood operating type, designed with limited bypass area; commonly used in conjunction with Variable Air Volume (VAV) exhaust systems and restricted sash opening designs Diversity – Percentage of total fume hood that are in operation at one time Safety Shield – Transparent horizontal panel used in conjunction with a bench fume hood and vertical-rising sash that provides added protection for the user Duct – Round, square, or rectangular tube used to enclose moving air Sash – Sliding glass panel set in the fume hood face that provides access to the fume hood interior Duct Velocity – Speed of air moving in duct, measured in feet per minute (FPM) Sash Operating Position – Position of the sash while work is being performed in fume hood, typically an 18” opening for vertical rising sashes Entrance – Fume hood front or access opening Exhaust Collar – Place where exhaust duct connects to fume hood and through which all exhaust air passes Exhaust Volume/Parameters – Quantity of air exhausted by the fume hood; quantity of air required to maintain desired face velocity, expressed in cubic feet per minute (CFM) 10 Sash setup Position – Position of the sash while the fume hood is being loaded with materials to perform work Service Fitting – Water faucets and gas valves mounted on or fastened to the fume hood Slot Velocity – Speed of air moving through fume hood baffle openings www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Fume Hood Technology Glossary (continued) Smoke Stick – Smoke-producing item used in evaluating fume hood airflow patterns and containment performance Static Pressure – Air pressure, or resistance, in fume hood or duct, expressed in inches of water Superstructure – Portion of the fume hood supported by base cabinets, the work surface or the floor Supplemental Air – Air delivered to a fume hood to reduce volume of air exhausted from room, also known as supply air; see Auxiliary Air Total Pressure – Sum of velocity pressure and static pressure as measured in duct Transport Velocity – Speed of air moving in duct; used when particles must be carried by air stream UL 1805 – Verifies conformance to electrical, mechanical and airflow characteristics VAV – See Variable Air Volume Variable Air Volume – Type of fume hood exhaust system that typically maintains constant fume hood face velocity by adjusting blower motor speed or a balance damper in response to changes in sash position Velocity – Speed of air, measured in Feet per Minute (FPM) Velocity Pressure – Force per square inch applied by moving air Velometer – Instrument used to measure air flow velocity Volume – Quantity of air, usually measured in cubic feet per minute (CFM) Water Gauge (WG) – Measuring device using the weight of a column of water, calibrated in inches Work Surface – Top material; area in fume hood where apparatus rests and where work takes place 11 Thermo Scientific Hamilton Air Flow Products General Fume Hood Operating Instructions Warning This product is intended for use with certain chemicals that can cause serious injury or illness through inhalation or physical contact. While this product is intended to minimize exposure to certain hazardous chemicals when selected, installed and operated properly, its performance and the safety of the user is affected by a number of factors. These include the HVAC system, the specific chemicals and processes being used, proper operation and the condition of the room. Before using this fume hood, consult the owner’s industrial hygienist or safety representative to make sure: 1) the specific fume hood alarms, controls and the HVAC system have been properly selected and are operating correctly, 2) the fume hood has been tested after installation and routinely thereafter to ensure the fume hood is providing the proper containment for the specific chemicals and processes being used, 3) there has been appropriate training on the correct use of the fume hood and handling of the specific chemicals and the fume hood operating instructions have been reviewed, 4) any personal protective devices that are required are properly selected and provided, and 5) the fume hood is being operated at the appropriate face velocity. The fume hood should never be operated with the sash in the full open position. Failure to follow these instructions could result in physical injury or illness 1) Do not use this fume hood unless you have received proper training from the owner’s industrial hygienist or safety representative. 2) This fume hood is not intended to be used with all chemicals or all chemical processes. Consult the owner’s industrial hygienist or safety representative to determine whether the fume hood is appropriate for the chemicals and processes to be used. 3) Verify that the fume hood exhaust system and controls are operating properly and providing the necessary air flow. If in doubt, the owner’s industrial hygienist or safety representative should be consulted. It is recommended that the fume hood be equipped with an air flow monitoring device. Before using the fume hood, verify that the monitor is operating properly by testing the monitor. 4) The fume hood should not be operated with the sash in the full open (setup) position. When the fume hood is in use, the opening of the sash glass should be kept at a minimum. On a vertical rising sash, the sash glass should be no higher than 18”. Horizontal sliding panels on combination sashes must be closed when sash is raised vertically. The sash should remain closed when the fume hood is not in use. 5) Place chemicals and other work materials at least six (6) inches inside the sash. 6) Do not restrict air flow inside the fume hood. Do not put large items in front of the baffles. Large apparatus should be elevated on blocks. Remove all materials not needed for the immediate work. The fume hood must not be used for storage purposes. 7) Never place your head inside the fume hood. 8) External air movement can affect the performance of the fume hood. Do not operate near open doors, open windows or fans. Avoid rapid body movements. Do not open the fume hood if there are cross-drafts or turbulence in front of the fume hood. Do not open the sash rapidly. 9) If this fume hood is equipped with adjustable baffles, do not adjust the baffles without consulting the owner’s industrial hygienist or safety representative. 10) Wear gloves and other protective clothing if contact with contaminants is a hazard. 11) Clean spills immediately. 12) If fumes or odors are present, stop operating the fume hood, close the sash and contact the owner’s industrial hygienist or safety representative immediately. 13) It is recommended that this fume hood be tested and certified annually by the owner according to applicable industry and government standards. 12 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Research and testing Quality Control Testing & Certification n The Thermo Scientific Hamilton Fume Hood Test Facility is used for quantitative and qualitative evaluations, quality control and product development purposes. The fully adjustable exhaust system can duplicate fume hood operating parameters, including face velocity and exhaust volume. n Testing and certification to ANSI/ASHRAE 110 1995 is standard procedure for each type and size of fume hood. Supply air temperatures can be adjusted to simulate both winter and summer conditions. n The location of air vents, traffic aisles and doorways can be recreated to simulate their impact on containment and face velocities. n Smoke generation equipment reveals airflow vectors under all conditions. Testing procedures include the following criteria: n Face velocity profile is generated from a computer which monitors a probe grid. Probes in the grid, which is placed in front of the fume hood, take multiple readings per second. n Fume hood containment is tested using a mannequin with a leak meter mounted to its breathing zone to simulate a person standing in front of a fume hood. When a tracer gas is injected into the fume hood, the meter measures escaping gas. Inspections are also performed at each critical stage in the manufacturing process to ensure that every fume hood is built to the highest Thermo Scientific Hamilton standards. Testing Custom Fume Hood Designs If none of the products in the standard offering will meet specific application requirements, Thermo Fisher Scientific technicians will develop a custom fume enclosure to perform to specifications. A prototype may be developed and operating parameters verified in the Fume Hood Test Facility. Prototypes and new designs are routinely subjected to this type of intensive testing. Technicians also will test samples of standard fume hood under specific operating conditions upon request. Customers are encouraged to be present at the Two Rivers facility for this testing. See Fume Hood in Operation Visits to the Product Showroom in Two Rivers, Wisconsin are encouraged. Several types of working fume hood are installed for personal inspection. Contact your local Thermo Fisher Scientific representative to set up an appointment. Visiting the showroom presents an opportunity to view all lines of Thermo Scientific Hamilton laboratory casework, furniture systems, fixtures and accessories. Testing for Special Lab Conditions – Before Purchase Achieving optimum fume hood operation is challenging under any circumstances due to the complexity of the variables involved. By evaluating a specific fume hood under a variety of operating conditions prior to purchase specifications are confirmed before installation. The Fume Hood Test Facility has a sealed, environmentally controlled chamber where critical aspects of a specific laboratory environment can be recreated. 13 Thermo Scientific Hamilton Air Flow Products Ordering Information Follow the steps in this section to select the best fume hood model for a particular application, then fit it out with appropriate options and accessories. Please record the following information before beginning: n Room size (length x width x height) n Lineal feet of fume hood space required n Room air changes per hour* n Lab heat load* n Type of lab and nature of work performed n Types of materials handled Step of use of apparatus to be used in the fume hood n Frequency n Sizes *Consult with the facilities manager or HVAC contractor. IMPORTANT: Fume hood must be carefully coordinated with the building’s HVAC system, sink outlet material, trap material, and building acid waste system. Failure to verify compatibility of these elements can result in costly alterations or less-than-optimal component or system function. Compatibility is the responsibility of the laboratory specifier, as is compliance with local and state codes. 1 Select a Physical Style Bench fume hood are superstructures designed for installation on base cabinet/work surface assemblies. High-line fume hood are bench models designed with extra interior clearance to accommodate apparatus up to 60” (1524 mm) high. Floor-mounted fume hood are designed for large, complex laboratory apparatus setups and roll-in equipment. For flexible work and storage arrangements, Floor-mounted fume hood can be combined with removable shelves and/or an adjustable-height table. Bench Step Floor Mounted 2 Determine if a Special-Purpose Fume Hood is Required A Special-Purpose fume hood may be required when, for example: n Radioactive materials or perchloric acid will be handled in the fume hood. n Neither a general-purpose high-line nor general-purpose floormounted model will accommodate especially tall or large apparatus. n Wheelchair-bound persons will be using the fume hood. n A classroom situation calls for special demonstration fume hood. If any of these conditions apply to a special situation, review special-purpose fume hood product pages. If one of these fume hood meet a particular need, continue with Step 4 to determine the base product number. If a special-purpose fume hood is required and none of the models in this catalog will meet a specific need, a Thermo Fisher Scientific representative will help design a custom fume hood for the specific requirements. Step High-line Special Purpose Fume Hood Education ADA Research/ Chemical Other Horizon Concept ADA Radioisotope Canopy Pass/Through Demonstration Perchloric Acid PaceAire Postless Sash Table Tops 3 Determine the Appropriate Operating Type By now a determination of the style and size of fume hood needed, and a decision made that you do not require a special purpose model. The next step is to determine the operating type that is most appropriate for the particular application. Refer to pages 4-9 for information on fume hood exhaust systems, and consult with the facilities manager, architect, lab planner, HVAC contractor, or Thermo Fisher Scientific representative if assistance is needed. The diagram illustrates the operating-type choices available for each style of general purpose fume hood. Review the product page for the fume hood that is preferred. If none of these models are appropriate, a Thermo Fisher Scientific representative will help design a custom fume hood that meets a specific requirement. General Purpose Fume Hood Bench Bench High-line Floor-mounted Bypass Bypass Bypass Auxiliary Air Auxiliary Air Auxiliary Air Restricted Bypass Restricted Bypass Restricted Bypass Restricted Bypass Distillation www.thermo.com/hamilton 14 Thermo Scientific Hamilton Air Flow Products Step 4 Select a Liner Material Liner Material Suffix* Advantages Disadvantages Polyresin P High illumination, easy to clean. Strong and resilient. High chemical resistance Cement-based Board R Low cost. Low light reflectivity. Difficult to clean. Brittle. Cement-based Board with White Enamel E High light reflectivity, easy to clean. Brittle. Stainless Steel S Work surface is caulked to superstructure. Subject to attack by some chemicals. Stainless Steel K Coved corners make this easy to clean. Ideal for Perchloric Acid use. Subject to attack by some chemicals. PVC C Excellent for highly corrosive applications. Material loses structural integrity when exposed to high temperatures. * Suffix for ordering purposes. See Page 151-152 for more complete liner descriptions. Step 5 Select a Liner Material The standard sash on most fume hood models is a vertical rising frameless sash. The unique frameless design captures the edge of the sash glass in a vertical sash track located behind the fume hood front corner post. In the event of an explosion, this positive containment design is significantly more effective in retaining the glass sheet than a framed sash. A second benefit of an unframed sash is full width visibility of the fume hood interior. Optional sash configurations include framed vertical rising, horizontal, and combination. If you are interested in energy conservation, compare the exhaust volume value in the Exhaust Parameters chart on the product information page with the exhaust volume indicated for the sash option being considered. The lower the exhaust volume value, the greater is the potential energy savings. Step Unframed Vertical Rising Framed Vertical Rising Combination Vertical/Horizontal Most fume hood models are available with an optional sash. Sash options applicable to each fume hood model are indicated on the specific product information page. Sash Types: O = Standard unframed F = Framed sash option B = Combination sash option - bench-top fume hood 6 Select a Color The two-digit color codes are listed separate from the product number. Three selections can be made: 1. Base Color - this is side panels and front vertical corner posts if an accent color is selected, or, the entire exterior panel surface if an accent color is not selected. 2. Accent Color - a second color applied to the lintel panel above the sash. 3. Sash/Sill - sash pull and sill airfoil will be the same color as the base color unless otherwise specified. Accent Color Base Color (entire fume hood exterior if no accent colors selected) Fume Hood Base and Accent Colors BK BL BS BD CH DK G1 G3 HG Sill/Sash (Base Color) Black Blue Blue Slate Brown Burgundy Chameleon Dark Khaki Dove Grey Grey Slate Hunter Green IN KK PW PM PL PA SA SS SW Indigo Khaki Petal White Piedmont Green Platinum Purple Sand Sandstone Shell White RECOMMENDATION: Prior to making your final selection, please contact your representative to obtain samples. 15 Thermo Scientific Hamilton Air Flow Products SafeAire II The Thermo Scientific Hamilton SafeAire II has been designed and tested to incorporate the latest in technology, performance and ergonomic features. The ergonomic flush sill provides user comfort, and the secondary trough increases safety SafeAire® II fume hood are available in either bench or floor-mounted designs of widths 36- to 96-inches and depths 31- to 43-inches. 16 www.thermo.com/hamilton Exterior Fluorescent Lighting Located safely away from harmful fumes and vapors, the fluorescent lighting system provides excellent task lighting. Louvered Bypass Louvers provide an additional source of exhaust air when the sash is lowered, helping to maintain consistent face velocities. Unique Exhaust Collar Design A contoured rectangular exhaust collar provides more vertical space, reduces noise levels and conserves energy by maintaining lower static pressure. Safety Monitor (Recommended) The optional electronic safety monitor activates an alarm if face velocity reaches a predetermined set point. Gasketed Access Panel Soft PVC gasket on the interior access panel eliminates contaminant seepage into sidewall. Remote Baffle Control The optional two-position remote baffle control can be used to adjust baffle position according to the types of fumes generated in the fume hood. Sash Safety Features The unframed sash design has greater impact resistance. The 18” sash lock/release defines the operating position. Liner Materials Several liner materials available and have low flame spread ratings and meet NFPA standards. Service Fixture Options A choice of remote control fixtures is available, all with acid-resistant finishes. The fixtures are color coded for added safety. Low Profile Air Foil The ergonomically designed airfoil provides obstruction-free access to the fume hood interior. The pivoting airfoil allows the operator to use a hospital grade 20 amp plug cord without obstructing the work area. Secondary Trough The secondary trough provides an additional safeguard for the containment of spills not secured by a dished work surface. Perimeter Baffle Slots Side slots increase fume containment and eliminate dead spaces where fumes can accumulate. Chemical-resistant Finish Independently tested 1.0-1.5 mil thick urethane powdercoat finish has excellent chemical and abrasion resistance. Thermo Scientific Hamilton fume hood finishes are SEFA 8 and U.S. Green Building Council LEED compliant in 18 standard colors. Increased Vertical Space The exhaust collar and baffle angle designs create additional space and are perfect for taller apparatus. Life-cycle Tested Sash Counter Balance System This system features a single weight and cable system. The full weight of the counterweight is retained in the event of a cable break. Metal-free Interior Five non-metallic liners are resistant to high temperatures and meet all NFPA 45 standards. Interiors do not have metal brackets, angles or screw heads (which can rust or corrode). Full-frame Construction All panels are attached to full-perimeter steel frame members for long term strength and durability. 17 SafeAire II Thermo Scientific Hamilton Air Flow Products Thermo Scientific Hamilton Air Flow Products Restricted Bypass Bench Superstructure For use with Constant Volume or Variable Air Volume Exhaust Systems for installation on 26-1/8” (663 mm) to 42” (1067 mm) deep work surface. n Recommended for use when an independent VAV controller (supplied by others) is utilized. n Also recommended for use with horizontal or combination sashes used in conjunction with VAV or constant volume systems. n Incorporates a 2” (51 mm) bypass above sash when closed to minimize leakage at minimum flow. n Vertical sash is full-view, laminated safety glass with full-width recessed pull. n 28-1/2” (724 mm) high opening for setup. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n Shipped assembled. n 31-1/4” deep fume hood require a sink base unit below a rear cupsink. n UL 1805 classified n See page 17 for additional product features common to all SafeAire II fume hood. Fume Hood Size Collar Size 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 6” x 9” (152 x 229 mm) 6” x 15” (152 x 381 mm) 6” x 23” (152 x 584 mm) 6” x 23” (152 x 381 mm) 6” x 30” (152 x 762 mm) 100 FPM Vertical Sash 28-1/2” Opening* CFM SP 100 FPM Vertical Sash 18” Opening* CFM SP 100 FPM Combination Sash 28-1/2” Opening CFM SP 520 .22 360 .12 N/A N/A 760 .18 485 .09 420 .06 1000 .18 660 .09 570 .07 1250 .27 785 .13 690 .12 1710 .26 1081 .09 980 .08 60-3/4” (1543 mm) Exhaust Parameters 54-1/4” (1378 mm) SafeAire II n Designed Depth End View See page 12 for operating instructions. *Vertical 28-1/2” sash opening is for setup only; operating position is an 18” opening. Combination sash volume is based on vertically closed. Horizontally open sash position. 18 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Restricted Bypass Bench Superstructure SafeAire II For Use With Constant Volume or Variable Air Volume Exhaust Systems Base Product Numbers 31-1/4” Depth Width 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) Fixed Baffle 54L2766___ 54L2769___ 54L2772___ 54L2775___ 54L2778___ Remote Baffle Adjustment 54L2768___ 54L2771___ 54L2774___ 54L2777___ 54L2780___ 36” Depth Fixed Baffle 60L2766P__ 60L2769P__ 60L2772P__ 60L2775P__ 60L2778P__ 37-1/4” Depth Remote Baffle Adjustment Fixed Baffle 60L2768P__ 60L2771P__ 60L2774P__ 60L2777P__ 60L2780P__ — 61L2769P__ 61L2772P__ 61L2775P__ 61L2778P__ Remote Baffle Adjustment — 61L2771P__ 61L2774P__ 61L2777P__ 61L2780P__ 43-1/4” Depth Fixed Baffle — 62L2769P__ 62L2772P__ 62L2775P__ 62L2778P__ Remote Baffle Adjustment — 62L2771P__ 62L2774P__ 62L2777P__ 62L2780P__ Liner Materials – Insert suffix in 8th digit of product number for 31-1/4” depth only: P – Polyresin R – Cement-based Board E – Cement-based Board/White Enamel S – Stainless Steel (Not available on 36” wide fume hood) C – PVC Sash Options – Insert suffix in 9th digit of product number: Sash Type Suffix Standard 0 Combination B Framed F See page 15 for additional sash information. 36” wide fume hood only available with standard sash. Side Panels – Insert suffix in 10th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95). Alarms (page 96). Work surfaces, cupsinks and traps (pages 98-103). Base cabinets (pages 105-108). Ceiling/Blower Enclosures (pages 110-118) Accessories (pages 119-123). 19 Thermo Scientific Hamilton Air Flow Products High-line Restricted Bypass Bench Superstructure For use with Constant Volume or Variable Air Volume Exhaust Systems for installation on 26-1/8” (663 mm) to 42” (1067 mm) deep work surface. n Extra-height interior to accommodate apparatus up to 60” (1524 mm) high. n Recommended when an independent VAV controller is used (supplied by others). n Also recommended for use with horizontal or combination sashes used in conjunction with VAV or constant volume systems. n Incorporates a 2” (51 mm) bypass above sash when closed to minimize leakage at minimum flow. n Vertical sash is full-view, laminated safety glass with full-width recessed pull. n Choice of 28-1/2” (724 mm) or 36” (914 mm) high opening for setup. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n Shipped assembled. n 31-1/4” deep fume hood require a sink base unit below a rear cupsink. n UL 1805 classified. n See page 17 for additional product features common to all SafeAire II fume hood. Exhaust Parameters 100 FPM 100 FPM 100 FPM 100 FPM 100 FPM Vertical Sash Vertical Sash Vertical Sash Horizontal Sash Horizontal Sash 28-1/2” Opening* 18” Opening* 36” Opening* 28-1/2” Opening 36” Opening Fume Hood Size Collar Size CFM SP CFM SP CFM SP CFM SP CFM SP 48” 6” x 15” (1219 mm) (152 x 381 mm) 60” 6” x 23” (1524 mm) (152 x 584 mm) 72” 6” x 23” (1829 mm) (152 x 584 mm) 96” 6” x 30” (2428 mm) (152 x 762 mm) 760 .18 485 .09 960 .27 420 .06 510 .06 1000 .18 660 .09 1260 .28 570 .07 690 .07 1250 .27 785 .13 1560 .35 690 .12 830 .12 1710 .26 1081 .09 2160 .34 980 .08 1180 .08 See page 12 for operating instructions. *Vertical 28-1/2” and 36” sash openings are for setup only; operating position is an 18” opening. Combination sash volume is based on vertically closed. Horizontally open sash position. 20 66-1/4” (1683 mm) SafeAire II n Designed Depth End View www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products High-line Restricted Bypass Bench Superstructure SafeAire II For Use With Constant Volume or Variable Air Volume Exhaust Systems Base Product Numbers 31-1/4” Depth 48” 48” 60” 60” 72” 72” 96” 96” Width Sash Opening Height (1219 mm) (1219 mm) (1524 mm) (1524 mm) (1829 mm) (1829 mm) (2438 mm) (2438 mm) 28-1/2’’ 36’’ 28-1/2’’ 36’’ 28-1/2’’ 36’’ 28-1/2’’ 36’’ (724 mm) (914 mm) (724 mm) (914 mm) (724 mm) (914 mm) (724 mm) (914 mm) Fixed Baffle 54L2801___ 54L2813___ 54L2804___ 54L2816___ 54L2807___ 54L2819___ 54L2810___ 54L2822___ Remote Baffle Adjustment 54L2803___ 54L2815___ 54L2806___ 54L2818___ 54L2809___ 54L2821___ 54L2812___ 54L2824___ 36” Depth 37-1/4” Depth Fixed Baffle Remote Baffle Adjustment Fixed Baffle 60L2801P__ 60L2813P__ 60L2804P__ 60L2816P__ 60L2807P__ 60L2819P__ 60L2810P__ 60L2822P__ 60L2803P__ 60L2815P__ 60L2806P__ 60L2818P__ 60L2809P__ 60L2821P__ 60L2812P__ 60L2824P__ 61L2801P__ 61L2813P__ 61L2804P__ 61L2816P__ 61L2807P__ 61L2819P__ 61L2810P__ 61L2822P__ Remote Baffle Adjustment 61L2803P__ 61L2815P__ 61L2806P__ 61L2818P__ 61L2809P__ 61L2821P__ 61L2812P__ 61L2824P__ 43-1/4” Depth Fixed Baffle 62L2801P__ 62L2813P__ 62L2804P__ 62L2816P__ 62L2807P__ 62L2819P__ 62L2810P__ 62L2822P__ Remote Baffle Adjustment 62L2803P__ 62L2815P__ 62L2806P__ 62L2818P__ 62L2809P__ 62L2821P__ 62L2812P__ 62L2824P__ Liner Materials – Insert suffix in 8th digit of product number for 31-1/4” depth only: P – Polyresin R – Cement-based Board E – Cement-based Board/White Enamel C – PVC Sash Options – Insert suffix in 9th digit of product number: Sash Type Suffix Standard 0 Combination B Framed F See page 15 for additional sash information. Side Panels – Insert suffix in 10th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95). Alarms (page 96) Work surfaces, cupsinks and traps (pages 98-103). Base cabinets (pages 105-108). Ceiling/Blower Enclosures (pages 110-118) Accessories (pages 119-123). 21 Thermo Scientific Hamilton Air Flow Products Constant Volume Bypass Bench Superstructure for installation on 26-1/8” (663 mm) to 42” (1067 mm) deep work surface. n Incorporates double bypass to maintain constant exhaust volume at all sash positions. n Designed to permit exact balancing of room ventilation system with fume hood exhaust volume. n Vertical sash is full-view, laminated safety glass with full-width recessed pull. n 28-1/2” (724 mm) high opening for setup. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n Shipped assembled. n 31-1/4” deep fume hood require a sink base unit below a rear cupsink. n UL 1805 classified. n See pages 17 for additional product features common to all SafeAire II fume hood. Fume Hood Size Collar Size 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 6” x 9” (152 x 229 mm) 6” x 15” (152 x 381 mm) 6” x 23” (152 x 584 mm) 6” x 23” (152 x 381 mm) 6” x 30” (152 x 762 mm) 100 FPM 28-1/2” Sash Opening* CFM SP 100 FPM 18” Sash Opening* CFM SP 520 .22 360 .12 760 .18 485 .09 1000 .18 660 .09 1250 .27 785 .13 1710 .26 1081 .09 60-3/4” (1543 mm) Exhaust Volumes 54-1/4” (1378 mm) SafeAire II n Designed Depth End View See page 12 for operating instructions. *28-1/2” openings are for setup only; operating position is an 18” opening. 22 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products SafeAire II Constant Volume Bypass Bench Superstructure Base Product Numbers Width 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 31-1/4” Depth Remote Fixed Baffle Baffle Adjustment 54L2586___ 54L2589___ 54L2592___ 54L2595___ 54L2598___ 54L2588___ 54L2591___ 54L2594___ 54L2597___ 54L2600___ 36” Depth Remote Fixed Baffle Baffle Adjustment 60L2586P__ 60L2589P__ 60L2592P__ 60L2595P__ 60L2598P__ 60L2588P__ 60L2591P__ 60L2594P__ 60L2597P__ 60L2600P__ 37-1/4” Depth Remote Fixed Baffle Baffle Adjustment — 61L2589P__ 61L2592P__ 61L2595P__ 61L2598P__ — 61L2591P__ 61L2594P__ 61L2597P__ 61L2600P__ 43-1/4” Depth Remote Fixed Baffle Baffle Adjustment — 62L2589P__ 62L2592P__ 62L2595P__ 62L2598P__ — 62L2591P__ 62L2594P__ 62L2597P__ 62L2600P__ Liner Materials – Insert suffix in 8th digit of product number for 31-1/4” depth only: P – Polyresin R – Cement-based Board E – Cement-based Board/White Enamel S – Stainless Steel (Not available on 36” wide fume hood) C – PVC Sash Options – Insert suffix in 9th digit of product number: Sash Type Suffix Standard 0 Framed F See page 15 for additional sash information. 36” wide fume hood only available with standard sash. Side Panels – Insert suffix in 10th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95). Alarms (page 96). Work surfaces, cupsinks and traps (pages 98-103). Base cabinets (pages 105-108). Ceiling/Blower Enclosures (pages 110-118). Accessories (pages 119-123). 23 Thermo Scientific Hamilton Air Flow Products High-line Constant Volume Bypass Bench Superstructure Exhaust Volumes Fume Hood Size 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) Collar Size 100 FPM 28-1/2” Sash Opening* CFM SP 6” x 15” 760 (152 x 381 mm) 6” x 23” 1000 (152 x 584 mm) 6” x 23” 1250 (152 x 381 mm) 6” x 30” 1710 (152 x 762 mm) 100 FPM 100 FPM 18” 36” Sash Opening* Sash Opening* CFM SP CFM SP .18 485 .09 960 .27 .18 660 .09 1260 .28 .27 785 .13 1560 .35 .26 1081 .09 2160 .34 See page 12 for operating instructions. *28-1/2” and 36” openings are for setup only; operating position is an 18” opening. 24 66-1/4” (1683 mm) SafeAire II Designed for installation on 26-1/8” (663 mm) to 42” (1067 mm) deep work surface. n Extra-height interior to accommodate apparatus up to 60” (1524 mm) high. n Incorporates a double bypass to maintain constant exhaust volume at all sash positions. n Designed to permit exact balancing of room ventilation system with fume hood exhaust volume. n Vertical sash is full-view, laminated safety glass with full-width recessed pull. n Choice of 28-1/2” (724 mm) or 36” (914 mm) high opening for setup. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n Shipped assembled. n 31-1/4” (794 mm) deep fume hood require a sink base unit below a rear cupsink. n UL 1805 classified. n See page 17 for additional product features common to all SafeAire II fume hood. n Depth End View www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products SafeAire II High-line Constant Volume Bypass Bench Superstructure Base Product Numbers Width 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60 (1524 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) Sash Opening Height 28-1/2” 36” 28-1/2” 36” 28-1/2” 36” 28-1/2” 36” (724 mm) (914 mm) (724 mm) (914 mm) (724 mm) (914 mm) (724 mm) (914 mm) 31-1/4” Depth Remote Baffle Fixed Baffle Adjustment 54L2685___ 54L2697___ 54L2688___ 54L2700___ 54L2691___ 54L2703___ 54L2694___ 54L2706___ 54L2687___ 54L2699___ 54L2690___ 54L2702___ 54L2693___ 54L2705___ 54L2696___ 54L2708___ 36” Depth Remote Fixed Baffle Baffle Adjustment 60L2685P__ 60L2697P__ 60L2688P__ 60L2700P__ 60L2691P__ 60L2703P__ 60L2694P__ 60L2706P__ 60L2687P__ 60L2699P__ 60L2690P__ 60L2702P__ 60L2693P__ 60L2705P__ 60L2696P__ 60L2708P__ 37-1/4” Depth Remote Fixed Baffle Baffle Adjustment 61L2685P__ 61L2697P__ 61L2688P__ 61L2700P__ 61L2691P__ 61L2703P__ 61L2694P__ 61L2706P__ 61L2687P__ 61L2699P__ 61L2690P__ 61L2702P__ 61L2693P__ 61L2705P__ 61L2696P__ 61L2708P__ 43-1/4” Depth Remote Fixed Baffle Baffle Adjustment 62L2685P__ 62L2697P__ 62L2688P__ 62L2700P__ 62L2691P__ 62L2703P__ 62L2694P__ 62L2706P__ 62L2687P__ 62L2699P__ 62L2690P__ 62L2702P__ 62L2693P__ 62L2705P__ 62L2696P__ 62L2708P__ Liner Materials – Insert suffix in 8th digit of product number for 31-1/4” depth only: P – Polyresin R – Cement-based Board E – Cement-based Board/White Enamel C – PVC Sash Options – Insert suffix in 9th digit of product number: Sash Type Suffix Standard 0 Framed F See page 15 for additional sash information. Side Panels – Insert suffix in 10th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95). Alarms (page 96). Work surfaces, cupsinks and traps (pages 98-103). Base cabinets (pages 105-108). Ceiling/Blower Enclosures (pages 110-118). Accessories (pages 119-123). 25 Thermo Scientific Hamilton Air Flow Products Perchloric Acid Restricted Bypass Superstructure For Use With Constant Volume or Variable Air Volume Exhaust Systems Fume Hood Size Collar Size 48” (1219 mm) 72” (1829 mm) 6” x 15” (152 x 381 mm) 6” x 23” (152 x 584 mm) 100 FPM @ 28-1/2” Sash Opening* CFM SP 100 FPM @ 18” Sash Opening* CFM SP 760 1250 485 785 .18 .27 See page 12 for operating instructions. *28-1/2” openings are for setup only; operating position is an 18” opening. .09 .13 60-3/4” (1543mm) Exhaust Volumes 54-1/4” (1378mm) SafeAire II Designed specifically and exclusively for perchloric acid procedures to minimize possibility of fire and explosion. n One-piece type 304 stainless steel interior includes dished work surface, with all joints coved, welded and ground. n Optional type 316 stainless steel interior with integral work surface for high abuse applications (Special order – extended leadtime). n Integral full-width trough at back of work surface for collection and disposal of wash-down waters; double drain for large volumes. n High-volume spray heads behind upper baffle. n Vertical sash is full-view, laminated safety glass with full-width recessed pull. n 28-1/2” (724 mm) high opening for setup. n One each remote control cold water faucet with vacuum breaker and control valve for fume hood washdown (Additional valves are required for duct washdown). n Two each 120 VAC black duplex receptacles and flush plates. n One vapor-proof light with black switch and flush plate on 48” (1219 mm) wide hood; two vapor-proof lights with one black switch and flush plate on 72” (1829 mm) wide fume hood. n Does not include sidewall access panel. n Baffles are non-adjustable. n Not labeled UL 1805. n See page 17 for additional product features common to all SafeAire II fume hood. n 31-1/4” (794 mm) End View 26 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Perchloric Acid Restricted Bypass Superstructure SafeAire II For Use With Constant Volume or Variable Air Volume Exhaust Systems Base Product Numbers Product No. Width 54L2793K__ 54L2797K__ 48” (1219 mm) 72” (1829 mm) Liner Material – Stainless steel Type 304, consult factory for optional Type 316 high-abuse stainless steel. Sash Options – Insert suffix in 9th digit of product number: Suffix Sash Type Standard 0 Framed F Side Panels – Insert suffix in 10th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95). Alarms (page 96). Ceiling/Blower Enclosures (pages 110-118). See pages 128-131 for blower requirements. 27 Thermo Scientific Hamilton Air Flow Products Constant Volume Radioisotope Bypass Superstructure n Fume Hood Size 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) Collar Size 6” x 15” (152 x 381 mm) 6” x 23” (152 x 584 mm) 6” x 23” (152 x 584 mm) 6” x 30” (152 x 762 mm) 100 FPM @ 28-1/2” Sash Opening* CFM SP 760 1000 1250 1710 .18 .18 .27 .26 100 FPM @ 18” Sash Opening* CFM SP 485 660 785 1081 .09 .09 .13 .09 54-1/4” (1378 mm) Exhaust Volumes 60-3/4” (1543 mm) SafeAire II Designed for handling of radioactive isotopes. One-piece type 304 stainless steel interior and work surface with integral cupsink located at left front corner, all corners coved, welded and ground (Relocating cupsink extends leadtime). n Filter system recommended; see page 125. n Weight capacity of reinforced work surface is 200 lbs per square foot. n Incorporates double bypass to maintain constant exhaust volume at all sash positions. n Designed to permit exact balancing of room ventilation system with hood exhaust volume. n Vertical sash is full-view, laminated safety glass with full-width recessed pull. n 28-1/2” (724 mm) high opening for setup. n Does not include sidewall access panel. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, two 120 VAC black duplex receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n Not labeled UL 1805. n See page 17 for additional product features common to all SafeAire II fume hood. n See page 12 for operating instructions. *28-1/2” openings are for setup only; operating position is an 18” opening. 31-1/4” (794 mm) End View 28 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Constant Volume Radioisotope Bypass Superstructure SafeAire II For Use With Constant Volume Exhaust Systems Base Product Numbers 48” 60” 72” 96” Width Fixed Baffle Remote Baffle Adjustment (1219 mm) (1524 mm) (1829 mm) (2438 mm) 54L2733K__ 54L2736K__ 54L2739K__ 54L2742K__ 54L2735K__ 54L2738K__ 54L2741K__ 54L2744K__ Liner Material – Stainless Steel, No Options Sash Options – Insert suffix in 9th digit of product number: Sash Type Suffix Standard 0 Framed F Side Panels – Insert suffix in 10th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95). Alarms (page 96). Base cabinets (pages105-108). Ceiling/Blower Enclosures (pages 110-118) Accessories (pages 119-123). Acid or Flammable Liquid storage cabinets cannot be positioned below the existing cupsinks. 29 Thermo Scientific Hamilton Air Flow Products Auxiliary Air Bench Superstructure For Use With Constant Volume Exhaust Systems Designed for installation on 30” (762 mm) to 42” (1067 mm) deep work surface. Designed to utilize semi-tempered outside air as supply air when total fume hood exhaust volume exceeds room exhaust volume requirements. n Designed to yield a higher percentage capture rate with lower auxiliary air velocities. n Vertical sash is full-view, laminated safety glass with full-width recessed pull. n 28-1/2” (724 mm) high opening for setup. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n Shipped assembled. n UL 1805 classified. n n Collar Size 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 6” x 15” (152 x 381 mm) 6” x 23” (152 x 584 mm) 6” x 23” (152 x 381 mm) 6” x 30” (152 x 762 mm) 100 FPM 18” Sash Opening* CFM SP 760 .18 485 .09 1000 .18 660 .09 1250 .27 785 .13 1710 .26 1081 .09 Depth + 10-1/2” (267 mm) 63-11/16” (1618 mm) Fume Hood Size 100 FPM 28-1/2” Sash Opening* CFM SP 54-1/4” (1378 mm) SafeAire Exhaust Volumes Supply Air Requirements Percent of Fume Hood Air Requirement Fume Hood Size 70% 60% 50% 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 100 FPM 28-1/2” Sash Opening* CFM 100 FPM 18” SashOpening* SP CFM SP 532 700 875 1197 456 600 750 1026 380 500 625 855 340 460 550 760 290 295 470 650 245 330 335 540 .14 .29 .34 .31 .12 .26 .26 .33 .09 .16 .20 .30 Depth End View .07 .14 .20 .26 .05 .12 .22 .202 .03 .10 .18 .17 See page 12 for operating instructions. *28-1/2” openings are for setup only; operating position is an 18” opening. 30 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Auxiliary Air Bench Superstructure For Use With Constant Volume Exhaust Systems Base Product Numbers Width 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 33-13/16” Depth Remote Fixed Baffle Baffle Adjustment 54L625___ 54L628___ 54L631___ 54L634___ 54L627___ 54L630___ 54L633___ 54L636___ 38-9/16” Depth Remote Fixed Baffle Baffle Adjustment 60L625P__ 60L628P__ 60L631P__ 60L634P__ 60L627P__ 60L630P__ 60L633P__ 60L636P__ 39-13/16” Depth Remote Fixed Baffle Baffle Adjustment 61L625P__ 61L628P__ 61L631P__ 61L634P__ 61L627P__ 61L630P__ 61L633P__ 61L636P__ 45-13/16” Depth Remote Fixed Baffle Baffle Adjustment 62L625P__ 62L628P__ 62L631P__ 62L634P__ 62L627P__ 62L630P__ 62L633P__ 62L636P__ SafeAire Liner Materials – Insert suffix in 7th digit of product number for 33-13/16” depth only: P – Polyresin R – Cement-based board E – Cement-based board/white enamel S – Stainless Steel C – PVC Sash Options – Insert suffix in 8th digit of product number: Sash Type Suffix Standard 0 Framed F See page 15 for additional sash information. Side Panels – Insert suffix in 9th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95). Alarms (page 96). Work surfaces, cupsinks and traps (pages 98-103). Base cabinets (pages 105-108). Ceiling/Blower Enclosures (pages 110-118). Accessories (pages 119-123). 31 Thermo Scientific Hamilton Air Flow Products High-line Auxiliary Air Bench Superstructure For Use With Constant Volume Exhaust Systems Designed to utilize semi-tempered outside air as supply air when total fume hood exhaust volume exceeds room exhaust volume requirement. n Designed for installation on 30” (762 mm) to 42” (1067 mm) deep work surface. n Extra-height interior to accommodate apparatus up to 60” (1524 mm) high. n Designed to yield a higher percentage capture rate with lower auxiliary air velocities. n More headroom than standard bench models. n Vertical sash is full-view, laminated safety glass with full-width recessed pull. n Choice of 28-1/2” (724 mm) or 36” (914 mm) high opening for setup. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n Shipped assembled. n UL 1805 classified. n 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) Collar Size 6” x 15” (152 x 381 mm) 6” x 23” (152 x 584 mm) 6” x 23” (152 x 584 mm) 6” x 30” (152 x 762 mm) 100 FPM 18” Sash Opening* CFM SP 100 FPM 36” Sash Opening* CFM SP 760 .18 485 .09 960 .27 1000 .18 660 .09 1260 .28 1250 .27 785 .13 1560 .35 1710 .26 1081 .09 2160 .34 Supply Air Requirements Percent of Fume Hood Air Requirement 70% 60% 50% Fume Hood Size 100 FPM 28-1/2” Sash Opening* CFM SP 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 532 700 875 1197 456 600 750 1026 380 500 625 855 .14 .29 .34 .31 .12 .26 .26 .33 .09 .16 .20 .30 100 FPM 18” Sash Opening* CFM SP 340 460 550 760 290 400 470 650 240 330 390 540 .08 .14 .17 .24 .06 .14 .16 .21 .04 .12 .13 .16 100 FPM 36” Sash Opening* CFM SP 672 882 1092 1517 576 756 936 1296 480 630 780 1080 Depth + 10-1/2” (267 mm) 74-1/4” (1886 mm) Fume Hood Size 100 FPM 28-1/2” Sash Opening* CFM SP 66-1/4” (1683 mm) SafeAire Exhaust Volumes 1-1/4” (32 mm) Depth End View .16 .33 .38 .41 .15 .30 .32 .37 .12 .22 .26 .33 See page 12 for operating instructions. *28-1/2” and 36” sash openings are for setup only; operating position is an 18” high sash opening. 32 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products High-line Auxiliary Air Bench Superstructure For Use With Constant Volume Exhaust Systems Base Product Numbers 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) Sash Opening Height 28-1/2” 36” 28-1/2” 36” 28-1/2” 36” 28-1/2” 36 (724 mm) (914 mm) (724 mm) (914 mm) (724 mm) (914 mm) (724 mm) (914 mm) 54L709___ 54L721___ 54L712___ 54L724___ 54L715___ 54L727___ 54L718___ 54L730___ 54L711___ 54L723___ 54L714___ 54L726___ 54L717___ 54L729___ 54L720___ 54L732___ 38-9/16” Depth Remote Fixed Baffle Baffle Adjustment 60L709P__ 60L721P__ 60L712P__ 60L724P__ 60L715P__ 60L727P__ 60L718P__ 60L730P__ 60L711P__ 60L723P__ 60L714P__ 60L726P__ 60L717P__ 60L729P__ 60L720P__ 60L732P__ 39-13/16” Depth Remote Fixed Baffle Baffle Adjustment 61L709P__ 61L721P__ 61L712P__ 61L724P__ 61L715P__ 61L727P__ 61L718P__ 61L730P__ 61L711P__ 61L723P__ 61L714P__ 61L726P__ 61L717P__ 61L729P__ 61L720P__ 61L732P__ 45-13/16” Depth Remote Fixed Baffle Baffle Adjustment 62L709P__ 62L721P__ 62L712P__ 62L724P__ 62L715P__ 62L727P__ 62L718P__ 62L730P__ 62L711P__ 62L723P__ 62L714P__ 62L726P__ 62L717P__ 62L729P__ 62L720P__ 62L732P__ SafeAire Width 33-13/16” Depth Remote Fixed Baffle Baffle Adjustment Liner Materials – Insert suffix in 7th digit of product number for 33-13/16” depth only: P – Polyresin R – Cement-based board E – Cement-based board/white enamel C – PVC Sash Options – Insert suffix in 8th digit of product number: Sash Type Suffix Standard 0 Framed F See page 15 for additional sash information. Side Panels – Insert suffix in 9th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95) Alarms (page 96) Work surfaces, cupsinks and traps (pages 98-103) Base cabinets (pages 105-108) Ceiling/Blower Enclosures (pages 110-118) Accessories (pages 119-123) 33 Thermo Scientific Hamilton Air Flow Products Restricted Bypass Floor-mounted For use with Constant Volume or Variable Air Volume Exhaust Systems Three standard depth choices. Designed for large and complex laboratory apparatus setups and roll-in equipment. n Recommended when an independent VAV controller is used (supplied by others). n Also recommended with horizontal or combination sash used in conjunction with VAV or constant volume systems. n Incorporates a 2” (51 mm) bypass to minimize leakage and maintain minimum flow. n Double-hung, vertical sash is full-view, laminated safety glass with full-width recessed pulls. n Sashes raise completely for easy setup (66-1/2” (1689 mm) sash opening). n Two side-wall access panels with PVC gasket on left side, one on right. n One cupsink included at front left location. The 96” (2438 mm) wide fume hood has one cupsink and two access panels at each side. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n All floor-mounted fume hood except those with stainless steel liners are shipped knocked-down and require job-site assembly. n UL 1805 classified. n n 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) Collar Size 6” x 15” (152 x 381 mm) 6” x 23” (152 x 584 mm) 6” x 23” (152 x 584 mm) 6” x 30” (152 x 762 mm) 100 FPM Combination (Horizontal) Sash Opening CFM SP 850 .18 480 .09 1110 .20 670 .09 1380 .32 790 .13 1900 .29 1125 1.00 See page 12 for operating instructions. *Floor mounted fume hood should be operated through a maximum face opening of 18” through a single sash with the other sash closed. 34 90” (2286 mm) Fume Hood Size 100 FPM 31-1/2” Vertical Sash Opening* CFM SP 100-11/16” (2557 mm) SafeAire Exhaust Volumes Depth End View www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Restricted Bypass Floor-mounted For Use With Constant Volume or Variable Air Volume Exhaust Systems Base Product Numbers Width 48” 60” 72” 96” (1219 mm) (1524 mm) (1829 mm) (2438 mm) 32-11/32” Depth Remote Baffle Fixed Baffle Adjustment 554S326___ 554S329___ 554S332___ 554S335___ 554S328___ 554S331___ 554S334___ 554S337___ 38-11/32” Depth Remote Fixed Baffle Baffle Adjustment 551S326P__ 551S329P__ 551S332P__ 551S335P__ 551S328P__ 551S331P__ 551S334P__ 551S337P__ 44-11/32” Depth Remote Fixed Baffle Baffle Adjustment 552S326P__ 552S329P__ 552S332P__ 552S335P__ 552S328P__ 552S331P__ 552S334P__ 552S337P__ SafeAire Liner Materials – Insert suffix in 8th digit of product number for 32-11/32” depth only: P – Polyresin S – Stainless Steel Sash Options – Insert suffix in 9th digit of product number: Sash Type Suffix Standard 0 Combination, upper frame only B Framed F See page 15 for additional sash information. Side Panels – Insert suffix in 10th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95) Alarms (page 96) Ceiling/Blower Enclosures (pages 110-118) Accessories (pages 119-123) 35 Thermo Scientific Hamilton Air Flow Products Restricted Bypass Distillation Floor-mounted For use with Constant Volume or Variable Air Volume Exhaust Systems Three standard depths available. Designed for large and complex laboratory apparatus setups and roll-in equipment. n Recommended for use with an independent VAV controller is used (supplied by others). n Also recommended with horizontal or combination sash used in conjunction with VAV or constant volume systems. n Includes removable stainless steel work surface, movable to two positions above floor level. n Incorporates a 2” (51 mm) bypass to eliminate leakage and maintain minimum flow. n Double-hung, vertical sash is full-view, laminated safety glass with full-width recessed pulls. n Sashes raise completely for easy setup (66-1/2” (1689 mm) sash opening). n One cupsink and two side-wall access panels with PVC gasket included at front left location. The 72” (1829 mm) wide fume hood has one cupsink and two access panels at each side. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n Plugged holes for future service fixture installation standard on both posts. n Cold water fixtures and cupsink available at front location only (due to work surface). n All floor-mounted fume hood except those with stainless steel liners are shipped knocked-down and require job-site assembly. n UL 1805 classified. n Fume Hood Size Collar Size 48” (1219 mm) 72” (1829 mm) 6” x 15” (152 x 381 mm) 6” x 23” (152 x 584 mm) 100 FPM 31-1/2” Sash Opening* CFM SP 850 .18 1380 .32 See page 12 for operating instructions. *Floor mounted fume hood should be operated through a maximum face opening of 18” through a single sash with the other sash closed. 36 90” (2286 mm) SafeAire Exhaust Volumes 100-11/16” (2557 mm) n Depth End View www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Restricted Bypass Distillation Floor-mounted For Use With Constant Volume or Variable Air Volume Exhaust Systems Base Product Numbers Width 48” (1219 mm) 72” (1829 mm) 32-11/32” Depth Remote Baffle Fixed Baffle Adjustment 38-11/32” Depth Remote Fixed Baffle Baffle Adjustment 554S344_0_ 554S346_0_ 551S344P0_ 554S347_0_ 554S349_0_ 551S347P0_ 551S346P0_ 551S349P0_ 44-11/32” Depth Remote Fixed Baffle Baffle Adjustment 552S344P0_ 552S347P0_ 552S346P0_ 552S349P0_ Liner Materials – Insert suffix in 8th digit of product number for 32-11/32” depth only: P – Polyresin S – Stainless Steel SafeAire Sash Options – Special order only Side Panels – Insert suffix in 10th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95) Alarms (page 96) Ceiling/Blower Enclosures (pages 110-118) Accessories (pages 119-123) 37 Thermo Scientific Hamilton Air Flow Products Constant Volume Floor-mounted For use with Constant Volume Exhaust Systems Three standard depth choices available. n Designed for large and complex laboratory apparatus setups and roll-in equipment. n Incorporates double bypass to maintain constant exhaust volume at all sash positions. n Designed to permit exact balancing of room ventilation system with fume hood exhaust volume. n Double-hung, vertical sash is full-view, laminated safety glass with full-width recessed pulls n Sashes raise completely for easy setup (66-1/2” (1689 mm) sash opening). n Two side-wall access panels with PVC gasket on left side, one on right. n One cupsink and two side-wall access panels with PVC gasket included at front left location; 96” (2438 mm) wide fume hood has two cupsinks and two access panels at each side. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n All floor-mounted fume hood except those with stainless steel liners are shipped knocked-down and require job-site assembly. n UL 1805 classified. n Collar Size 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 6” x 15” (152 x 381 mm) 6” x 23” (152 x 584 mm) 6” x 23” (152 x 584 mm) 6” x 30” (152 x 762 mm) 850 .18 1110 .20 1380 .32 1900 .29 See page 12 for operating instructions. *Floor mounted fume hood should be operated through a maximum face opening of 18” through a single sash with the other sash closed. 38 90” (2286 mm) Fume Hood Size 100 FPM 31-1/2” Sash Opening* CFM SP 100-11/16” (2557 mm) SafeAire Exhaust Volumes Depth End View www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Constant Volume Floor-mounted Base Product Numbers Width 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 32-11/32” Depth Remote Fixed Baffle Baffle Adjustment 554S705___ 554S708___ 554S711___ 554S714___ 554S707___ 554S710___ 554S713___ 554S716___ 38-11/32” Depth Remote Fixed Baffle Baffle Adjustment 551S705P__ 551S708P__ 551S711P__ 551S714P__ 551S707P__ 551S710P__ 551S713P__ 551S716P__ 44-11/32” Depth Remote Fixed Baffle Baffle Adjustment 552S705P__ 552S708P__ 552S711P__ 552S714P__ 552S707P__ 552S710P__ 552S713P__ 552S716P__ SafeAire Liner Materials – Insert suffix in 8th digit of product number for 32-11/32” depth only: P – Polyresin S – Stainless Steel Sash Options – Insert suffix in 9th digit of product number: Sash Type Suffix Standard 0 Framed F See page 15 for additional sash information. Side Panels – Insert suffix in 10th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95) Alarms (page 96) Ceiling/Blower Enclosures (pages 110-118) Accessories (pages 119-123) 39 Thermo Scientific Hamilton Air Flow Products Constant Volume Auxiliary Air Floor-mounted Three standard depth choices available. n Designed for large and complex laboratory apparatus setups and roll-in equipment. n Designed to utilize semi-tempered outside air when total fume hood exhaust volume exceeds room exhaust volume required. n Designed to yield a higher percentage capture rate with lower auxiliary air velocities. n Double-hung, vertical sash is full-view, laminated safety glass with full-width recessed pulls. n Sashes raise completely for easy setup (66-1/2” (1689 mm) sash opening). n One cupsink and two side-wall access panels with PVC gasket included at front left location. The 96” (2438 mm) wide fume hood has one cupsink and two access panels at each side. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n All floor-mounted fume hood except those with stainless steel liners are shipped knocked-down and require job-site assembly. n UL 1805 classified. n Percent of Fume Hood Air Requirement 70% 60% Fume Hood Size 100 FPM 31-1/2” Sash Opening* CFM SP 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 532 700 875 1197 456 600 750 1026 Depth + 5-1/2” (1153 mm) 40-3/8” (1026 mm) .14 .29 .34 .31 .12 .26 .26 .33 98” (2489 mm) 90” (2286 mm) SafeAire Supply Air Requirements Exhaust Volumes Fume Hood Size Collar Size 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 6” x 15” (152 x 381 mm) 6” x 23” (152 x 584 mm) 6” x 23” (152 x 584 mm) 6” x 30” (152 x 762 mm) 100 FPM 31-1/2” Sash Opening* CFM SP 850 .18 1110 .20 1380 .32 1900 .29 End View 101-3/8” (2564 mm) Depth *Floor-mounted fume hood should be operated through a maximum face opening of 18” through a single sash with the other sash closed. See page 12 for operating instructions. 40 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Constant Volume Auxiliary Air Floor-mounted For use with Constant Volume Exhaust Systems Base Product Numbers Width 48” (1219mm) 60” (1524mm) 72” (1829mm) 96” (2438mm) 34-15/16” Depth Remote Baffle Fixed Baffle Adjustment 554S720___ 554S723___ 554S726___ 554S729___ 554S722___ 554S725___ 554S728___ 554S731___ 40-15/16” Depth Remote Fixed Baffle Baffle Adjustment 551S720P__ 551S723P__ 551S726P__ 551S729P__ 551S722P__ 551S725P__ 551S728P__ 551S731P__ 46-15/16” Depth Remote Fixed Baffle Baffle Adjustment 552S720P__ 552S723P__ 552S726P__ 552S729P__ 552S722P__ 552S725P__ 552S728P__ 552S731P__ SafeAire Liner Materials – Insert suffix in 8th digit of product number for 34-15/16” depth only: P – Polyresin S – Stainless Steel Sash Options – Insert suffix in 9th digit of product number: Sash Type Suffix Standard 0 Framed F See page 15 for additional sash information. Side Panels – Insert suffix in 10th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95) Alarms (page 96) Ceiling/Blower Enclosures (pages 110-118) Accessories (pages 119-123) 41 Thermo Scientific Hamilton Air Flow Products Combination Bench/Floor-mounted Constant Volume Combination bench/floor-mounted assembly consisting of fume hood superstructure, work surface and base cabinets. n Designed for unlimited access to work area for setup of wide apparatus. n Half of work surface is removable; cupboard base cabinet opens for roll-in capability. n Air foil design with double bypass to maintain constant exhaust volume at all sash positions. n Fixed work surface is dished epoxy resin; removable surface is flat stainless steel. n Choice of left or right side floor-mounted. n Vertical sash is full-view, laminated safety glass with full-width recessed pull. n 28-1/2” (724 mm) high opening for setup. n Polyresin liner; no options. n Two double-tube (T-8) fluorescent light fixtures, black light switch and flush plate, two 120 VAC black duplex receptacles and flush plates. n Plugged holes for future service fixture installation standard on both posts. n 96” (2438 mm) width only. n Extended lead time. n UL 1805 classified. n Fume Hood Size Collar Size 96” (2438 mm) 6” x 30” (152 x 762 mm) 100 FPM @ 28-1/2” Sash Opening* CFM SP 1710 .26 See page 12 for operating instructions. *28-1/2” openings are for setup only; operating position is an 18” opening. 89-1/2” (2273 mm) SafeAire Exhaust Volumes 31-1/4” (794 mm) End View 42 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Combination Bench/Floor-mounted Bypass Assembly For use with Constant Volume Exhaust Systems Base Product Numbers Product No. Fixed Baffle 554S350P_ 554S353P_ Remote Baffle Adjustment 554S352P_ 554S355P_ Walk-In Side Left Right Left Right Liner Material – Polyresin, no options. SafeAire Side Panels – Insert suffix in 9th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95) Alarms (page 96) Ceiling/Blower Enclosures (pages 110-118) Accessories (pages 119-123) 43 Thermo Scientific Hamilton Air Flow Products Framed Postless Sash Restricted Bypass Superstructure For use with Constant Volume or Variable Air Volume Exhaust Systems Designed for installation on 30” (762 mm) deep work surface. Designed for unlimited access to work area for setup of wide apparatus. n Two independently-operating framed vertical sashes are full-view, laminated safety glass with full-width recessed pull and disappearing guides. n 28-1/2” (724 mm) high opening for setup. n Incorporates a restricted bypass to eliminate leakage and maintain minimum flow. n Polyresin liner; no options. n Two-tube (T-8) fluorescent light fixtures, black light switch and flush plate, two 120 VAC black duplex receptacles and flush plates. n Plugged holes for future service fixture installation standard on both posts. n 120” (3049 mm) and 144” (3658 mm) wide units shipped in two sections and require job-site assembly and central support to ceiling. n Two exhaust collars each on 120” (3049 mm) and 144” (3658 mm) models. n UL 1805 classified. n Fume Hood Size Collar Size 72” (1829 mm) 96” (2438 mm) 120” (3048 mm) 144” (3658 mm) 6” x 23” (152 x 584 mm) 6” x 30” (152 x 762 mm) Two 6” x 23” (152 x 584 mm) Two 6” x 23” (152 x 584 mm) 100 FPM @ 28-1/2” Sash Opening* CFM SP 100 FPM @ 18” Sash Opening* CFM SP 1250 .27 785 .13 1710 .26 1081 .09 2180 .18 1384 .10 2660 .29 1684 .15 54-1/4” (1378 mm) SafeAire Exhaust Volumes Based on both sashes open 60-3/4” (1543 mm) n 31-1/4” (794 mm) End View See page 12 for operating instructions. *28-1/2” openings are for setup only; operating position is an 18” opening. 44 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Framed Postless Sash Restricted Bypass Superstructure For use with Constant Volume or Variable Air Volume Exhaust Systems Base Product Numbers 72” 96” 120” 144” Width Fixed Baffle Remote Baffle Adjustment (1829mm) (2438mm) (3048mm) (3658mm) 54L781P__ 54L784P__ 54L787P__ 54L790P__ 54L783P__ 54L786P__ 54L789P__ 54L792P__ SafeAire Liner Material – Polyresin, no options: Sash Type – Insert suffix in 8th digit of product number: Sash Type Suffix Combination B Framed F Side Panels – Insert suffix in 9th digit of product number: U – Without side panels L – Left side only R – Right side only B – Both sides Other Information – To complete the fume hood assembly, refer to the sections listed below: Fixtures (pages 88-95) Alarms (page 96) Work Surfaces, Cupsinks and Traps (pages 98-103) Base Cabinets (pages 105-108) Ceiling/Blower Enclosures (pages 110-118) Accessories (pages 119-123) 45 Thermo Scientific Hamilton Air Flow Products Pass-through Demonstration Assembly For use with Constant Volume or Variable Air Volume Exhaust Systems Designed to permit demonstration and observation from either side. Assembly consists of a Restricted Bypass fume hood superstructure, work surface and base cabinets. n Can be used freestanding or positioned in a wall between a classroom and a prep room. n Two 30” (762 mm) wide wood base cabinets with double hinged doors and one shelf. Cabinets are not double-faced. n Work surface is 1-1/4” (32 mm) thick epoxy resin without marine edge. n Standard fixtures include: one cold water gooseneck faucet; two single gas fixtures; two black duplex AC outlets/flush plates; one 16” x 8” x 7” (406 mm x 203 mm x 178 mm) molded resin sink; two exhaust collars. Maximum two fixtures per side. n All electrical is pre-wired to a junction box at the top of the fume hood. n Two full-view vertically rising sashes made of 7/32” (6 mm) laminated safety glass with recessed pulls (one each side). n 28-1/2” (724 mm) high opening for setup. n Fixed baffle position. n Two-tube (T-8) fluorescent light fixture (protected by safety glass panel) and black light switch/flush plate, mounted on each side of fume hood. n Optional sash interlock 90L162N0 allows only one sash to be opened at a time (special order and extended lead time). n 60” (1524 mm) wide. n UL 1805 classified (only with 90L162N0 sash interlock factory installed). n Fume Hood Width Collar Size (Two Collars) 60” (1524 mm) 6” x 15” (152 x 381 mm) 100 FPM @ 18”* Sash Opening CFM SP 700 54-1/4” (1378 mm) 89” (2661 mm) SafeAire Exhaust Volumes Based on sash open one side only. 96” (2438 mm) n .1 See page 12 for operating instructions. *28-1/2” openings are for setup only; operating position is an 18” opening (one side only). 32-1/2” (826 mm) End View 46 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Pass-through Demonstration Assembly For Use With Constant Volume or Variable Air Volume Exhaust Systems Base Product Number Product No. Complete Assembly 554C325E_ 554C325P_ Superstructure Only 54L825E0_ 54L825P0_ Width Liner Material 60” (1524 mm) 60” (1524 mm) Cement-based board – white enamel Polyresin 60” (1524 mm) 60” (1524 mm) Cement-based board – white enamel Polyresin Optional sash interlock Order product number 90L162N0; requires extended lead time. SafeAire Side Panels – Add suffix to end of product number: U – Without side panels L – Left side only R – Right side only B – Both sides 47 Thermo Scientific Hamilton Air Flow Products This page is intentionally blank. 48 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products 35” High Sightline Optimum visibility of the fume hood interior. Downdraft Bypass Air flows through the bypass area with increased volume and less resistance for quieter operation. Thermo Scientific Hamilton AutoSash Automatic Positioning System The sash locks in the setup position and automatically returns to the maximum operational height when the lock is released. Low Profile Airfoil Ergonomically designed to provide obstruction free access to the fume hood interior. Improved Combination Sash Top hung frameless sash panels with ball-bearing rollers for smooth operation. The reduced frame profile with a radiused bottom edge provides maximum interior visibility and minimum turbulence. Chain & Sprocket Sash Support System The counterbalance system features a chain and sprocket sash support system with alignment shaft and sash leveling system. Fixed Baffle System The baffle system requires no adjustment as it’s factory tuned for optimal airflow characteristics. 49 Concept 35” Thermo Scientific Hamilton Air Flow Products Constant Volume and Restricted Bypass Add the following suffix letter to product numbers below for side panel requirements: U = Without side panels. L = Left side only. R = Right side only. B = Both sides. See next Page for exhaust volumes. See Page 98-101 for work surfaces. Product Numbers Constant Volume Vertical Rising Unframed Sash 31-1/4” Depth* 37-1/4” Depth 43-1/4” Depth Width 54L2570P0_ 54L2571P0_ 54L2572P0_ 54L2573P0_ 54L2574P0_ 61L2570P0_ 61L2571P0_ 61L2572P0_ 61L2573P0_ 61L2574P0_ 62L2570P0_ 62L2571P0_ 62L2572P0_ 62L2573P0_ 62L2574P0_ 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 53” (1346 mm) 63-1/2” (1613 mm) Restricted Bypass Vertical Rising Unframed Sash Bypass and restricted bypass vertical rising sash 31-1/4” Depth* 37-1/4” Depth 43-1/4” Depth Width 54L2750P0_ 54L2751P0_ 54L2752P0_ 54L2753P0_ 54L2754P0_ 61L2750P0_ 61L2751P0_ 61L2752P0_ 61L2753P0_ 61L2754P0_ 62L2750P0_ 62L2751P0_ 62L2752P0_ 62L2753P0_ 62L2754P0_ 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) Depth Vertical Sash Restricted Bypass Combination Sash Concept 31-1/4” Depth* 37-1/4” Depth 43-1/4” Depth Width 54L2750PB_ 54L2751PB_ 54L2752PB_ 54L2753PB_ 54L2754PB_ 61L2750PB_ 61L2751PB_ 61L2752PB_ 61L2753PB_ 61L2754PB_ 62L2750PB_ 62L2751PB_ 62L2752PB_ 62L2753PB_ 62L2754PB_ 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 69-1/2” (1765 mm) 53” (1346 mm) * 31-1/4” deep fume hood require a sink base unit below a rear cupsink. Restricted bypass combination sash Depth Combination Sash 50 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Exhaust Volumes Concept Fume Hood with Combination Sash Concept Fume Hood with Vertical Sash Sash Opening Vertical Sash Opening Height Face Velocity Static Pressure Exhaust Collar Size 484 18* 28.5* 100 60 .09” 6” x 15” 400 60” 634 18* 28.5* 100 60 .09” 6” x 23” 72” 784 18* 28.5* 100 60 .13” 84” 934 18* 28.5* 100 60 1084 18* 28.5* 100 60 Fume Hood Width Exhaust Volume 48” 96” Face Velocity Horizontal Sash Opening Sliding Sash Panels 18* 24* 27 x 17.375 540 18* 24* 6” x 23” 650 .15” 6” x 26” .09” 6” x 30” * 28-1/2” and 24” opening is for setup only; operating position is an 18” high sash opening. Vertical Exhaust Sash Volume Height Vertical** Horizontal Static Pressure Exhaust Collar Size 2 80 60 100 .07” 6” x 15” 27 x 23.375 2 80 60 100 .07” 6” x 23” 18* 24* 27 x 28.250 4 80 60 100 .11” 6” x 23” 790 18* 24* 27 x 34.250 4 80 60 100 .13” 6” x 26” 930 18* 24* 27 x 40.250 4 80 60 100 .07” 6” x 30” ** Vertical face velocities – nominal. Minimum Variable Air Volume Face Velocity – 60-FPM Horizontal Sash CFM - S.P. 225 - .02 530 - .07 400 - .04 24 18 305 - .03 650 - .11 500 - .08 24 18 370 - .04 775 - .12 590 - .07 24 18 430 - .04 900 - .07 680 - .04 24 18 525 - .03 Concept Concept with combination sash Exhaust Volume Vertical Sash CFM S.P. Inches 400 - .07 24 300 - .04 18 51 Thermo Scientific Hamilton Air Flow Products High-line Constant Volume and Restricted Bypass Add the following suffix letter to product numbers below for side panel requirements: U = Without side panels. L = Left side only. R = Right side only. B = Both sides. See next page for exhaust volumes. See Page 98-101 for work surfaces. Product Numbers - 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) Polyresin Liner, Vertical Rising Sash, Restricted Bypass 31-1/4” Depth* 37-1/4” Depth 43-1/4” Depth Width 54L2641P0_ 54L2642P0_ 54L2643P0_ 54L2644P0_ 54L2645P0_ 61L2641P0_ 61L2642P0_ 61L2643P0_ 61L2644P0_ 61L2645P0_ 62L2641P0_ 62L2642P0_ 62L2643P0_ 62L2644P0_ 62L2645P0_ 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) Polyresin Liner, Combination Sash, Restricted Bypass Vertical rising sash 31-1/4” Depth* 37-1/4” Depth 43-1/4” Depth Width 54L2641PB_ 54L2642PB_ 54L2643PB_ 54L2644PB_ 54L2645PB_ 61L2641PB_ 61L2642PB_ 61L2643PB_ 61L2644PB_ 61L2645PB_ 62L2641PB_ 62L2642PB_ 62L2643PB_ 62L2644PB_ 62L2645PB_ 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 65” (1651 mm) Width 62L2650P0_ 62L2651P0_ 62L2652P0_ 62L2653P0_ 62L2654P0_ 38” (956 mm) Siteline 43-1/4” Depth 61L2650P0_ 61L2651P0_ 61L2652P0_ 61L2653P0_ 61L2654P0_ 32” (813 mm) Max. Vert. Opening 37-1/4” Depth 54L2650P0_ 54L2651P0_ 54L2652P0_ 54L2653P0_ 54L2654P0_ 28-1/2” (724 mm) Lock Open Position 31-1/4” Depth* 71” (1830 mm) Polyresin Liner, Vertical Rising Sash, Constant Volume Depth Vertical Sash Concept 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) Stainless Steel Liner, Vertical Rising Sash, Constant Volume Combination and Horizontal sash 31-1/4” Depth* 37-1/4” Depth 43-1/4” Depth Width 54L2650S0_ 54L2651S0_ 54L2652S0_ 54L2653S0_ 54L2654S0_ 61L2650S0_ 61L2651S0_ 61L2652S0_ 61L2653S0_ 61L2654S0_ 62L2650S0_ 62L2651S0_ 62L2652S0_ 62L2653S0_ 62L2654S0_ 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) Stainless Steel Liner, Vertical Rising Sash, Restricted Bypass 31-1/4” Depth* 37-1/4” Depth 43-1/4” Depth Width 54L2641S0_ 54L2642S0_ 54L2643S0_ 54L2644S0_ 54L2645S0_ 61L2641S0_ 61L2642S0_ 61L2643S0_ 61L2644S0_ 61L2645S0_ 62L2641S0_ 62L2642S0_ 62L2643S0_ 62L2644S0_ 62L2645S0_ 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 65” (1651 mm) Width 62L2641PC_ 62L2642PC_ 62L2643PC_ 62L2644PC_ 62L2645PC_ 38” (956 mm) Siteline 43-1/4” Depth 61L2641PC_ 61L2642PC_ 61L2643PC_ 61L2644PC_ 61L2645PC_ 32” (813 mm) Max. Vert. Opening 37-1/4” Depth 54L2641PC_ 54L2642PC_ 54L2643PC_ 54L2644PC_ 54L2645PC_ 28-1/2” (724 mm) Lock Open Position 31-1/4” Depth* 76” (1930 mm) Polyresin Liner, Horizontal Sash, Restricted Bypass Depth Combination Sash Stainless Steel Liner, Combination Sash, Restricted Bypass 31-1/4” Depth* 37-1/4” Depth 43-1/4” Depth Width 54L2641SB_ 54L2642SB_ 54L2643SB_ 54L2644SB_ 54L2645SB_ 61L2641SB_ 61L2642SB_ 61L2643SB_ 61L2644SB_ 61L2645SB_ 62L2641SB_ 62L2642SB_ 62L2643SB_ 62L2644SB_ 62L2645SB_ 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) Stainless Steel Liner, Horizontal Sash, Restricted Bypass 31-1/4” Depth* 37-1/4” Depth 43-1/4” Depth Width 54L2641SC_ 61L2641SC_ 62L2641SC_ 48” (1219 mm) 54L2642SC_ 61L2642SC_ 62L2642SC_ 60” (1524 mm) 54L2643SC_ 61L2643SC_ 62L2643SC_ 72” (1829 mm) 54L2644SC_ 61L2644SC_ 62L2644SC_ 84” (2134 mm) 54L2645SC_ 61L2645SC_ 62L2645SC_ 96” (2438 mm) * 31-1/4” deep fume hood require a sink base unit below a rear cupsink. 52 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Exhaust Volumes Concept High-line Fume Hood with Vertical Sash Vertical Sash Face Opening Velocity Static Height (Nominal) Pressure Fume Hood Width Exhaust Volume Exhaust Collar Size 48” 510 18* 28.5* 100 65 .09” 6” x 15” 60” 670 18* 28.5* 100 65 .09” 6” x 23” 72” 825 18* 28.5* 100 65 .13” 6” x 23” 84” 980 18* 28.5* 100 65 .15” 6” x 26” 96” 1150 18* 28.5* 100 65 .09” 6” x 30” *28-1/2” opening is for setup only; operating position is an 18” high sash opening. Concept High-line Fume Hood with Combination Sash Sash Opening Face Velocity (Nominal) Vertical Sash Height Horizontal Sash Opening Sliding Sash Static Panels Vertical Horizontal Pressure Exhaust Collar Size 48” 510 18* 28.5* 30.5 x 17.375 2 105 65 110 .08” 6” x 15” 60” 670 18* 28.5* 30.5 x 23.375 2 105 65 110 .09” 6” x 23” 72” 825 18* 28.5* 30.5 x 28.250 4 105 65 110 .12” 6” x 23” 84” 980 18* 28.5* 30.5 x 34.250 4 105 65 110 .13” 6” x 26” 96” 1150 18* 28.5* 30.5 x 40.250 4 105 65 110 .09” 6” x 30” Concept Fume Hood Exhaust Width Volume *28-1/2” opening is for setup only; operating position is an 18” high sash opening. Concept High-line Fume Hood with Horizontal Sash Exhaust volumes based on 100 FPM 31-1/2” vertical sash opening, bypass* area included. Fume Hood Width Exhaust Volume (CFM) Face Velocity (Nominal) Static Pressure Loss (Inches W.G.) Horizontal Sash Opening (Height x Width) 48” 460 100 0.08 31.5 x 17.375 60” 72” 84” 96” 620 750 910 1060 100 100 100 100 0.09 0.12 0.14 0.09 31.5 x 23.375 31.5 x 28.250 31.5 x 34.250 31.5 x 40.250 *Bypass is based on 3” by the interior width of the fume hood. (1” at the sill and 2” above the sash behind the lintel panel). 53 Thermo Scientific Hamilton Air Flow Products Constant Volume/Restricted Bypass Floor-mounted Fume Hood with Vertical Sash Three standard depth choices available. Designed for large and complex laboratory apparatus setups and roll-in equipment. n Double-hung, vertical rising sash is full-view, laminated safety glass with fullwidth recessed pulls. n AutoSash upper automatic sash positioning system – sash locks in setup position and automatically returns to maximum operational height of 18” when lock is released. n Chain and sprocket sash counterbalance system features alignment shaft and sash leveling system. n Preset fixed baffle system – no adjustment required – factory tuned for optimal airflow characteristics. n Downdraft bypass – improves airflow through bypass area with increased volume and less resistance for quieter operation. n One cupsink and two side-wall access panels with PVC gasket included at front left location. 84” (2134 mm) and 96” (2438 mm) wide fume hood have two cupsinks and two access panels at each side. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n All floor-mounted fume hood except those with stainless steel liners are shipped knocked-down and require job-site assembly. n UL 1805 classified. n n Exhaust Volume (CFM) 48” 60” 72” 84” 96” 28.5” 28.5” 28.5” 28.5” 28.5” 790 1035 1285 1520 1770 Based on 100 FPM at 18” Static Pressure Top Sash Height* Exhaust Volume (CFM) Static Pressure 0.17 0.19 0.30 0.28 0.30 18” 18” 18” 18” 18” 508 666 824 983 1141 0.10 0.09 0.14 0.15 0.11 *Both sashes raise for setup only, operating position is an 18” high sash opening. 66-1/2” Total Sash Opening Top Vertical Sash Opening Height* 71” Viewing Height Based on Top Sash at 100 FPM Fume Hood Width 89-1/2” (2273 mm) Concept Exhaust Volume 28-1/2” Lock Open 36-1/2” Lower Sash Depth End View 54 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Constant Volume/Restricted Bypass Floor-mounted Fume Hood with Vertical Sash Product Numbers 35” (889 mm) Depth 41” (1041 mm) Constant Volume fume hood with Stainless Steel Liner 48” (1219 mm) 554S2741S0_ 551S2741S0_ 60” (1524 mm) 554S2742S0_ 551S2742S0_ 72” (1829 mm) 554S2743S0_ 551S2743S0_ 84” (2134 mm) 554S2744S0_ 551S2744S0_ 96” (2438 mm) 554S2745S0_ 551S2745S0_ Constant Volume fume hood with Polyresin Liner 48” (1219 mm) 554S2741P0_ 551S2741P0_ 60” (1524 mm) 554S2742P0_ 551S2742P0_ 72” (1829 mm) 554S2743P0_ 551S2743P0_ 84” (2134 mm) 554S2744P0_ 551S2744P0_ 96” (2438 mm) 554S2745P0_ 551S2745P0_ Restricted Bypass fume hood with Stainless Steel Liner 48” (1219 mm) 554S2746S0_ 551S2746S0_ 60” (1524 mm) 554S2747S0_ 551S2747S0_ 72” (1829 mm) 554S2748S0_ 551S2748S0_ 84” (2134 mm) 554S2749S0_ 551S2749S0_ 96” (2438 mm) 554S2750S0_ 551S2750S0_ Restricted Bypass fume hood with Polyresin Liner 48” (1219 mm) 554S2746P0_ 551S2746P0_ 60” (1524 mm) 554S2747P0_ 551S2747P0_ 72” (1829 mm) 554S2748P0_ 551S2748P0_ 84” (2134 mm) 554S2749P0_ 551S2749P0_ 96” (2438 mm) 554S2750P0_ 551S2750P0_ 47” (1194 mm) 552S2741S0_ 552S2742S0_ 552S2743S0_ 552S2744S0_ 552S2745S0_ 552S2741P0_ 552S2742P0_ 552S2743P0_ 552S2744P0_ 552S2745P0_ 552S2746S0_ 552S2747S0_ 552S2748S0_ 552S2749S0_ 552S2750S0_ 552S2746P0_ 552S2747P0_ 552S2748P0_ 552S2749P0_ 552S2750P0_ Concept Width Add the following suffix letter to product numbers above for side panel requirements: U = Without side panels L = Left side only R = Right side only B = Both sides 55 Thermo Scientific Hamilton Air Flow Products Restricted Bypass Floor-mounted Fume Hood with Combination Sash Three standard depth choices available. Designed for large and complex laboratory apparatus setups and roll-in equipment. n Double-hung, vertical rising top-hung combination sash is full-view, laminated safety glass with full-width recessed pulls. n AutoSash upper automatic sash positioning system – sash locks in setup position and automatically returns to maximum operational height of 18” when lock is released. n Chain and sprocket sash counterbalance system features alignment shaft and sash leveling system. n Preset fixed baffle system, no adjustment required. Factory tuned for optimal airflow characteristics. n Downdraft bypass improves airflow through bypass area with increased volume and less resistance for quieter operation. n One cupsink and two side-wall access panels with PVC gasket included at front left location. 84” (2134 mm) and 96” (2438 mm) wide fume hood have two cupsinks and two access panels at each side. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n All floor-mounted fume hood except those with stainless steel liners are shipped knocked-down and require job-site assembly. n UL 1805 classified. n n 28.5” 28.5” 28.5” 28.5” 28.5” Exhaust Volume Static (CFM) Pressure 790 1035 1285 1520 1770 0.17 0.19 0.30 0.28 0.30 Top Sash Height 18” 18” 18” 18” 18” 18” Horizontal Exhaust Static Face Face Volume Pressure Velocity Velocity 508 666 824 983 1141 0.10 0.09 0.14 0.15 0.11 100 100 100 100 100 110 110 110 110 110 *Both sash assemblies raise for setup only, providing a 66-1/2” clearance; however the operating positions are an 18” vertical sash opening on or with the top vertical component closed and the sliding panels opened. 71” Viewing Height 48” 60” 72” 84” 96” Top Vertical Sash Opening Height* 66-1/2” Total Sash Opening Fume Hood Width Based on 100 FPM at 18” 89-1/2” (2273 mm) Concept Exhaust Volume Based on Top Sash at 100 FPM 27-1/2” Lock Open 36-1/2” Lower Sash Depth End View 56 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Restricted Bypass Floor-mounted Fume Hood with Combination Sash Product Numbers Width 35” (889 mm) Depth 41” (1041 mm) 47” (1194 mm) Restricted Bypass fume hood with and Stainless Steel Liner 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 554S2751SB_ 554S2752SB_ 554S2753SB_ 554S2754SB_ 554S2755SB_ 551S2751SB_ 551S2752SB_ 551S2753SB_ 551S2754SB_ 551S2755SB_ 552S2751SB_ 552S2752SB_ 552S2753SB_ 552S2754SB_ 552S2755SB_ Restricted Bypass fume hood with and Polyresin Liner 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 554S2751PB_ 554S2752PB_ 554S2753PB_ 554S2754PB_ 554S2755PB_ 551S2751PB_ 551S2752PB_ 551S2753PB_ 551S2754PB_ 551S2755PB_ 552S2751PB_ 552S2752PB_ 552S2753PB_ 552S2754PB_ 552S2755PB_ Concept Add the following suffix letter to product numbers above for side panel requirements: U = Without side panels L = Left side only R = Right side only B = Both sides 57 Thermo Scientific Hamilton Air Flow Products Restricted Bypass Floor-mounted Fume Hood with Horizontal Sliding Sash Three standard depth choices available. Designed for large and complex laboratory apparatus setups and roll-in equipment. n Full-view top-hung horizontal sliding sash with laminated safety glass. n Preset fixed baffle system, no adjustment required. Factory tuned for optimal airflow characteristics. n Downdraft bypass – improves airflow through bypass area with increased volume and less resistance for quieter operation. n One cupsink and two side-wall access panels with PVC gasket included at front left location. 84” (2134 mm) and 96” (2438 mm) wide fume hood have two cupsinks and two access panels at each side. n Two-tube (T-8) fluorescent light fixture, black light switch and flush plate, and two black duplex 120 VAC receptacles and flush plates. n 96” (2438 mm) wide units have two light fixtures. n Plugged holes for future service fixture installation standard on both posts. n All floor-mounted fume hood except those with stainless steel liners are shipped knocked-down and require job-site assembly. n UL 1805 classified. n n Product Numbers Depth 35” (889 mm) 41” (1041 mm) 47” (1194 mm) Restricted Bypass fume hood with Stainless Steel Liner 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 554S2760SC_ 554S2761SC_ 554S2762SC_ 551S2760SC_ 551S2761SC_ 551S2762SC_ 552S2760SC_ 552S2761SC_ 552S2762SC_ Restricted Bypass fume hood with Polyresin Liner 551S2760PC_ 551S2761PC_ 551S2762PC_ 552S2760PC_ 552S2761PC_ 552S2762PC_ Add the following suffix letter to product numbers above for side panel requirements: U = Without side panels L = Left side only R = Right side only B = Both sides Exhaust Volume Based on Two Sashes Open at 100 FPM Fume Top Vertical Hood Sash Opening Exhaust Static Width Height Volume (CFM) Pressure 72” 84” 96” 58 66.5” 66.5” 66.5” 1485 1770 2070 66-1/2” Total Sash Opening 554S2760PC_ 554S2761PC_ 554S2762PC_ 71” Viewing Height 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 89-1/2” (2273 mm) Concept Width Depth End View 0.35 0.33 0.35 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Distillation Shelf for Concept Floor-mounted Fume Hood n Steel shelf attaches to side walls Product No. Fume Hood Width Concept For 35” deep Fume Hood 54L38210 48” (1219 mm) 54L50210 60” (1524 mm) 54L62210 72” (1829 mm) 54L74210 84” (2134 mm) 54L86210 96” (2438 mm) For 41” deep Fume Hood 54L38270 48” (1219 mm) 54L50270 60” (1524 mm) 54L62270 72” (1829 mm) 54L74270 84” (2134 mm) 54L86270 96” (2438 mm) For 47” deep Fume Hood 54L38330 48” (1219 mm) 54L50330 60” (1524 mm) 54L62330 72” (1829 mm) 54L74330 84” (2134 mm) 54L86330 96” (2438 mm) 59 Thermo Scientific Hamilton Air Flow Products Concept ADA Assemblies For Use With Constant Volume or Variable Air Volume Exhaust Systems Convenient access from standing or sitting position. Restricted bypass operating type. n Interior panels for access to utilities; removable front post for fixture type. n Flush bottom air foil. n 1-1/4” (32 mm) thick dished epoxy resist work surface for primary containment. Order separately. n Spill trough assembly for secondary containment – urethane powdercoat finish. n Baffle screen prevents paper and objects from being exhausted into ductwork. n Combination horizontal/vertical sash with safety glass viewing panel. n Auto-sash positions vertical operating height at 18”. n Extra high sash provides clear vision line for standing user, even when hood is located at lower work surface height. 35” sash viewing height. n Two-tube (T-8) fluorescent light fixture protected by safety glass panel. n Available in standard 31-1/4” (794 mm) depth, or optional 37-1/4” (946 mm) depth. n Chain/sprocket counter balance. n Designed for 60-100 FPM face velocities. n One combination light switch/receptacle and one duplex prewired to a junction box. n n 69-1/2” 53” Depth Concept ADA Concept ADA Fume Hood with Combination Sash Product Numbers Width 48” 60” 72” 84” 96” (1219 mm) (1524 mm) (1829 mm) (2134 mm) (2438 mm) Width 48” 60” 72” 84” 96” (1219 mm) (1524 mm) (1829 mm) (2134 mm) (2438 mm) Depth Product Number 31.25” 31.25” 31.25” 31.25” 31.25” 54L2755PB 54L2756PB 54L2757PB 54L2758PB 54L2759PB Depth Product Number 37.25” 37.25” 37.25” 37.25” 37.25” 61L2755PB 61L2756PB 61L2757PB 61L2758PB 61L2759PB Only available with combination sash Order side panels separately, see page 115 * 31-1/4” deep Fume Hood require a sink base unit below a rear cupsink 60 Sash Opening Fume Vertical Hood Exhaust Sash Width Volume Height Face Velocity Horizontal Sash Opening Sliding Sash Panels Vertical** Horizontal Static Pressure Exhaust Collar Size 48” 18* 24* 400 27 x 17.375 2 80 60 100 .07” 6” x 15” 60” 18* 24* 540 27 x 23.375 2 80 60 100 .07” 6” x 23” 72” 18* 24* 650 27 x 28.250 4 80 60 100 .11” 6” x 23” 84” 18* 24* 790 27 x 34.250 4 80 60 100 .13” 6” x 26” 96” 18* 24* 930 27 x 40.250 4 80 60 100 .07” 6” x 30” ** Vertical face velocities – nominal * 24” openings is for setup only See page 98 for work surfaces See page 108 for ADA height base cabinets www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Restricted Bypass Pioneer Fume Hood Superstructure 35” High Sightline Provides users with optimum visibility of fume hood interior. Designed to maximize containment performance and energy efficiency, the Thermo Scientific Hamilton Directed Airflow Technology makes this possible. Subjected to both standard and modified ASHRAE test procedures, the Pioneer has been tested at face velocities as low as 50 fpm, sash fully open, with unmatched performance. Fixed Baffle System The baffle system is factory-tuned for optimal airflow characteristics and requires no adjustment. Chain and Sprocket Sash Support System The counter-balance system features alignment shaft and sash leveling device. Laminar Airflow Control Module Directed air flow helps purge operator’s breathing zone with room air when sash is raised above the 18” operating position. Dual Performance Monitor A multifunction control system monitors both the sash opening and the directed airflow system. AutoSash Automatic Positioning System Sash locks in setup position and automatically returns to maximum operational height when lock is released. Low Profile Sill Airfoil Ergonomically designed airfoil provides obstruction-free access to fume hood interior. Directed Airflow Technology Pioneer Setup Position – Sash above 18” to full open, laminar flow control module activated. Operating Position – Sash at 18” to closed, laminar flow control module deactivated. 61 Thermo Scientific Hamilton Air Flow Products Restricted Bypass Add the following suffix letter to product numbers below for side panel requirements: U = Without side panels, L = Left side only, R = Right side only, B = Both sides. Vertical 70.5” (1791 mm) Unframed Sash 53” (1346 mm) 37-1/4” (946 mm) Product Numbers Restricted Bypass Vertical Rising Unframed Sash 37-1/4” Depth Width 61L2655P0_ 48” 61L2656P0_ 60” 61L2657P0_ 72” 61L2658P0_ 84” 61L2659P0_ 96” Includes front ceiling/sash enclosure Pioneer Technical Data Pioneer Fume Hood with Vertical Sash Fume Hood Width Exhaust Volume 48” 440 60” 580 72” 715 84” 855 96” 990 Vertical Sash Opening Height Face Velocity 18* 27.5* 18* 27.5* 18* 27.5* 18* 27.5* 18* 27.5* 92 60 92 60 92 60 92 60 92 60 Static Pressure Exhaust Collar Size .08” 6” x 15” .08” 6” x 23” .12” 6” x 23” .14” 6” x 26” .08” 6” x 30” *27-1/2” opening is for setup only; operating position is an 18” high sash opening. 62 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Restricted Bypass Horizontal 73.5” (1867 mm) Combination Sash 53” 1346 mm) 37-1/4” (946 mm) Product Numbers Restricted Bypass Combination Sash 37-1/4” Depth Width 61L2655PB_ 48” 61L2656PB_ 60” 61L2657PB_ 72” 61L2658PB_ 84” 61L2659PB_ 96” Includes front ceiling/sash enclosure Technical Data Pioneer Fume Hood with Combination Sash Exhaust Volume 48” 440 60” 580 72” 715 84” 855 96” 990 18 27.5 18 27.5 18 27.5 18 27.5 18 27.5 Sash Opening Horizontal Sash Opening Sliding Sash Panels Face Velocity 28.5 x 17.375 2 28.5 x 23.375 2 28.5 x 28.250 4 28.5 x 34.250 4 28.5 x 40.250 4 Vertical 92 60 92 60 92 60 92 60 92 60 Horizontal Static Pressure Exhaust Collar Size 110 .08” 6” x 15” 110 .08” 6” x 23” 110 .12” 6” x 23” 110 .14” 6” x 26” 110 .08” 6” x 30” Pioneer Fume Hood Width Vertical Sash Height Spacer for Full-height Door Cabinets n n Pioneer fume hood incorporate a unique bottom airfoil sill that enhances air flow performance. The sill extends over the cabinet front. Base cabinets with full-height doors or full-overlay upper panels require a spacer between the cabinet and work surface to provide clearance. 30-3/4” depth Product No. 619S2480 619S2600 619S2720 619S2840 619S2960 Width 48” 60” 72” 84” 96” 63 Thermo Scientific Hamilton Air Flow Products Fume hood designed to address the ever-increasing requirements for safety, energy-efficiency and aesthetics. n The Advantage™ Fume Hood feature enhanced ergonomics for user comfort. n A full-height slanted front viewing area and side viewing panels enable simple and easy monitoring of precious samples. n With optional low voltage LED lighting, minimal exhaust static pressure, and variable air volume (VAV) compatibility to minimize exhaust air when the sash is down, the Advantage fume hood provides energy-efficient hazard containment. n The flush sill enhances safety by eliminating possible glassware tripping hazards. n AutoSash™ technology maximizes laboratory safety by ensuring correct sash positioning. n An additional trough is positioned at the front of the unit to catch any spills. Advantage COMBINATION SASH VERTICAL SASH Advantage Fume Hood CFMs 64 Fume Hood Width Exhaust Volume 48” (1219 mm) 435 60” (1524 mm) 570 72” (1829 mm) 700 84” (2134 mm) 840 96” (2438 mm) 975 Fume Hood Width Exhaust Volume 48” (1219 mm) 345 60” (1524 mm) 455 72” (1829 mm) 555 84” (2134 mm) 665 96” (2438 mm) 775 Vertical Sash Opening Face Velocity 18” (457 mm) 85 26” (660 mm) 60 18” (457 mm) 85 26” (660 mm) 60 18” (457 mm) 85 26” (660 mm) 60 18” (457 mm) 85 26” (660 mm) 60 18” (457 mm) 85 26” (660 mm) 60 Vertical Sash Opening Vertical Face Velocity 18 70 22 60 18 70 22 60 18 70 22 60 18 70 22 60 18 70 22 60 Static Pressure Collar Size 0.1 10” (254 mm) 0.13 10” (254 mm) 0.13 12” (305 mm) 0.12 12” (305 mm) 0.14 12” (305 mm) Hortizontal Sash Opening (HxW) Horitzontal Face Velocity Static Pressure Collar Size 24-1/2” x 18-3/4” 100 0.07 10” (254 mm) 24-1/2” x 24-3/4” 100 0.09 10” (254 mm) 24-1/2” x 30” 100 0.09 12” (305 mm) 24-1/2” x 36” 100 0.12 12” (305 mm) 24-1/2” x 42” 100 0.13 12” (305 mm) www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Vertical Rising Unframed Sash T8 flourescent lamps T8 LED lamps Common Features n Petal white color steel interior Width 33-1/2” Depth 39-1/2” Depth 33-1/2” Depth 39-1/2” Depth n Offered only with front loaded fixtures 48” 56L250T0 59L250T0 56L250L0 59L250L0 n 48” and 60” fume hood have a 10” round exhaust collar 60” 56L251T0 59L251T0 56L251L0 59L251L0 n 72”, 84” and 96” fume hood have a 12” round exhaust collar 72” 56L252T0 59L252T0 56L252L0 59L252L0 n Pre-wired with two black duplex receptacles and one black light switch 84” 56L253T0 59L253T0 56L253L0 59L253L0 96” 56L254T0 59L254T0 56L254L0 59L254L0 Combination Sash T8 flourescent lamps T8 LED lights lamps Width 33-1/2” Depth 39-1/2” Depth 33-1/2” Depth 39-1/2” Depth 48” 56L250TB 59L250TB 56L250LB 59L250LB 60” 56L251TB 59L251TB 56L251LB 59L251LB 72” 56L252TB 59L252TB 56L252LB 59L252LB 84” 56L253TB 59L253TB 56L253LB 59L253LB 96” 56L254TB 59L254TB 56L254LB 59L254LB Replacement LED Bulb One standard lamp 36” fixture requires 2 (two) 56L31LED replacement bulbs. 48” fixture 56L41LED Work Surfaces Width No Cupsink Left Front Cupsink Left Rear Cupsink Right Front Cupsink Right Rear Cupsink 2 Front Cupsinks Fume Hood Depth Fume Hood Depth Fume Hood Depth Fume Hood Depth Fume Hood Depth Fume Hood Depth 33-1/2” 39-1/2” 33-1/2” 39-1/2” 33-1/2” 39-1/2” 33-1/2” 39-1/2” 33-1/2” 39-1/2” 33-1/2” 39-1/2” – – – – – – – – 48” 21L4829000 21L4835000 21L48290LF 21L48350LF 21L48290LR 21L48350LR 21L48290RF 21L48350RF 21L48290RR 21L48350RR 60” 21L6029000 21L6035000 21L60290LF 21L60350LF 21L60290LR 21L60350LR 21L60290RF 21L60350RF 21L48290RR 21L60350RR 72” 21L7229000 21L7235000 21L72290LF 21L72350LF 21L72290LR 21L72350LR 21L72290RF 21L72350RF 21L72290RR 21L72350RR 84” 21L8429000 21L8435000 21L84290LF 21L84350LF 21L84290LR 21L84350LR 21L84290RF 21L84350RF 21L84290RR 21L84350RR 96” 21L9629000 21L9635000 21L96290LF 21L96350LF 21L96290LR 21L96350LR 21L96290RF 21L96350RF 21L96290RR 21L96350RR 21L96290BF 21L96350BF Optional Fume Hood End Panels Optional Back Enclosure Panel Depth Left End Right End Width Product No. 33-1/2” 56LLH34D 56LRH34D 48” 54L48600LBEP 39-1/2” 59LLH40D 59LRH40D 60” 54L60600LBEP 72” 54L72600LBEP 84” 54L84600LBEP 96” 54L96600LBEP Fixtures Product No. 32L715GW Front load pre-piped air 32L715AW Front load pre-piped vac 32L715VW Front load pre-piped CW 32L715CW Package includes all parts necessary to operate fume hood Advantage Front load pre-piped gas 65 Thermo Scientific Hamilton Air Flow Products * Infinity 48” Infinity shown with filters 72” Infinity shown with filters 60” Infinity shown with filters 96” Infinity shown with filters The Infinity™ line of innovative fume hood maintains user safety, is environmentally friendly and can generate savings. n GreenFumeHood® technology eliminates atmospheric pollution from the exhaust, reduces building infrastructure and dramatically reduces energy consumption costs. n The GreenFumeHood technology utilizes Neutrodine® filters in place of traditional carbon filters to eliminate emissions. * 3” minimum air space required between top of filter and ceiling. 66 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Include comparable size GFH technology assembly with each fume hood superstructure. Working Sash Opening 18” 18” 18” 18” Infinity Vertical Rising Unframed Sash Product No. Full Open Sash 59L350T0 22” 59L351T0 22” 59L352T0 22” 59L354T0 20” Width 48” 60” 72” 96” GFH Technology As. Product No. 48” filter package 59LPK400 60” filter package 59LPK500 72” filter package 59LPK600 96” filter package 59LPK800 Width 48” 60” 72” 96” No Cupsinks 21L4835100 21L6035100 21L7235100 21L9635100 Optional Fume Hood End Panels Product No. Side panels right 59LRH40F Side panels left 59LLH40F Package includes filters and all parts necessary to operate fume hood Work Surfaces Left Front Cupsink 21L48351LF 21L60351LF 21L72351LF 21L96351LF Right Front Cupsink 21L48351RF 21L60351RF 21L72351RF 21L96351RF 2 Front Cupsinks N/A N/A N/A 21L96352BF Notes: n Petal white color steel interior n Offered only with front loaded fixtures n Pre-wired with two black duplex receptacles Optional Back Enclosure Panel Width Product No. 48” 54L48525LBEP 60” 54L60525LBEP 72” 54L72525LBEP 96” 54L96525LBEP Fixtures Accessories Product No. Product No. Front load pre-piped gas 32L715GW Neutrodine filter 59LNE100 Replacement Front load pre-piped air 32L715AW Acid sensor 59LAC100 Replacement Front load pre-piped vac 32L715VW G guard software* 59LGSW00 Optional Front load pre-piped CW 32L715CW Hepa filter 59LHE100 Optional * Provides Microsoft interlink. One needed per project for up to 200 fume hood. Example of Complete Unit Order: Product No. GFH Filtered Infinity Fume Hood – Description 59L352T0 6” Filtered Infinity Hood; PW; Flourescent Light; Vertical Rising Sash 59LRH40F 40” D RH End-Panel-Filtered 59LLH40F 40” D LH End-Panel-Filtered 59LPK600 Filtered Technology Package 6’ Structure 21L7235100 40” D; Filtered hood top, no cupsinks; 6’ fume hood 32L715GW Front Loaded Pre-piped GAS fixture, 1/4” copper tubing 32L715AW Front Loaded Pre-piped AIR fixture, 1/4” copper tubing 32L715VW Front Loaded Pre-piped VAC fixture, 1/4” copper tubing 32L715CW Front Loaded Pre-piped CW fixture, 1/4” copper tubing; w/Gooseneck 20L91920 Cupsink cut-out 34L13700 Cupsink 3” x 6” I.D. Shallow 59GSW00 G Guard Software *1 PER PROJECT* (optional) 67 Thermo Scientific Hamilton Air Flow Products • Adaptable Product Offering – Choose from 48”, 60” and 72” widths in both single- and doublesided configurations. • Improved Visibility – Full-view side and back glass panels provide visibility for spotting hazardous situations. • Verifiable Performance – All Horizon fume hood meet or exceed ASHRAE 110 95 standards. • State-of-the-Art Airflow – Perimeter exhaust slots provide uniform airflow through the fume hood for added safety. Horizon • Lower Operating Costs – Lower static pressure ratings require lower initial system investment and more economical long-term operating costs. Multiple-unit Capability – Two Horizon fume hood placed side-byside sharing a common end. • Improved Access to Hood Interior – The flush air foil sill eliminates the vertical obstruction common to traditional raised sill style air foils. • Secondary Spill Containment – Integral spill trough along front edge of work surface provides additional protection from dangerous chemical spills. • More Usable Work Surface – Service fixtures are mounted in an isolated vertical service drop compartment in the fume hood interior, providing a larger work surface area. Perimeter Exhaust Slots – Improve airflow through the fume hood. Epoxy Resin Work Surfaces – With ”dished” edge for added spill containment. • More Interior Work Area – Air foil front with narrow post design provides more usable interior width. • Easier Handling Upon Delivery – Horizon units ship knocked-down for reduced freight costs and easier transport through interior doorways. • Lifetime Durability – Sash counterbalance system is life-tested to 100,000 cycles. • UL 1805 Classification – Covers electrical, mechanical, flammability and airflow characteristics Remote Control Service Valves – Easily accessible; no need to dismantle the fume hood for service. 68 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Horizon AutoSash Automatic 18” Sash Operating Opening – Reduces exhaust air and provides added face and upper body protection. Side Panels – Constructed of 7/32” laminated safety glass for excellent visibility and user protection. • • Isolated Service Drop – Allows for vertical fixture mounting away from the work surface. • Flush Air Foil Sill – Provides easy access to work surface. • Secondary Spill Containment Trough – Extra protection from the hazards associated with spills and accidents. • Wood Base Cabinets – Available in your choice of several standard finishes. 69 Thermo Scientific Hamilton Air Flow Products Horizon Full-view For Use With Constant Volume or Variable Air Volume Exhaust Systems Designed to facilitate total visibility of the entire lab from any location. Single-faced wall style or double-faced island models available; can be ”ganged” side-by-side. n Restricted bypass can be operated as constant volume with supplied header panels. n Back panel on single units is white polyresin (optional glass back panel is available on extended lead times); side panels and vertical sash are 7/32” (6 mm) laminated safety glass. n Back, side and sash panels on island units are 7/32” laminated safety glass. n Services, when specified, include remote control gas, air, vacuum and cold water with 3” x 6” (76 x 152 mm) cupsink. Service controls are base cabinet mounted. n If services are not specified, plugged fixture holes are provided for future use. n Automatic 18” (457 mm) sash stop. n 34” (864 mm) high opening for setup. n Standard dished epoxy resin work surface. Order separately. n Integral spill trough along front edge of work surface for secondary spill containment. n Narrow angled front posts for enhanced visibility and airflow. n Flush sill air foil for easy access to work surface. n Isolated service drop allows vertical fixture mounting for maximum work surface area. n Perimeter exhaust slots provide uniform airflow. n Two-tube (T-8) fluorescent light fixture. n 48” wide assembly has one combination light switch/receptacle and flush plate in right base cabinet. 60” wide assembly has one combination light switch/receptacle and flush plate in right base cabinet; one 120 VAC duplex receptacle and flush plate in left base cabinet. 72” wide assembly has one light switch and flush plate, and one 120 VAC duplex receptacle and flush plate in right base cabinet; one 120 VAC duplex receptacle and flush plate in left base cabinet. n n Horizon Optional lattice rack available. Ordered separately. Ships knocked-down. Product number includes superstructure, work surface, base cabinets and fillers. n Not applicable for use in highly corrosive environments. n UL 1805 classified. n Order optional. Only 54LAFA1000 can be used with this Fume Hood alarm separately. n n Standalone or Multiple-unit Assembly Components Instead of double ends between units, Horizon multipleunit assemblies include a cost-effective common end with a single pane of glass between adjoining units. Two-unit assemblies include a right and left connector. Three-unit assemblies include a right connector, middle, left connector. Additional middle units can be added for assemblies of more than three units. When building multiple unit assemblies, assemble fume hood from right unit to left unit. Standalone Suffix ”N” 70 Left end is referred to as ”R” product because it connects on its right side. Left End Suffix ”R” Right Side Connector Middle Suffix ”B” Right End Suffix ”L” Left Side Connector www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Horizon Product Numbers Stand-alone Superstructure Product Numbers Width Without Fixtures Fixtures Right Side Only Fixtures Both Sides Without Fixtures Single-faced Style 48” (1219 mm) 60” (1219 mm) 72” (1219 mm) 554C403N 554C405N 554C409N 554C403NR 554C405NR 554C409NR (Not Available) 554C405NB 554C409NB 54L853N0 54L854N0 54L855N0 54L853NR 54L854NR 54L855NR (Not Available) 54L854NB 54L855NB Double-faced Style 48” (1219 mm) 60” (1219 mm) 72” (1219 mm) 554C404N 554C406N 554C410N 554C404NR 554C406NR 554C410NR (Not Available) 554C406NB 554C410NB 54L850N0 54L851N0 54L852N0 54L850NR 54L851NR 54L852NR (Not Available) 54L851NB 54L852NB Left-end Assembly Product Numbers Fixtures Right Side Only Fixtures Both Sides Left-end Superstructure Product Numbers Width Without Fixtures Fixtures Right Side Only Fixtures Both Sides Without Fixtures Single-faced Style 48” (1219 mm) 60” (1219 mm) 72” (1219 mm) 554C403R 554C405R 554C409R 554C403RR 554C405RR 554C409RR (Not Available) 554C405RB 554C409RB 54L853R0 54L854R0 54L855R0 54L853RR 54L854RR 54L855RR (Not Available) 54L854RB 54L855RB Double-faced Style 48” (1219 mm) 60” (1219 mm) 72” (1219 mm) 554C404R 554C406R 554C410R 554C404RR 554C406RR 554C410RR (Not Available) 554C406RB 554C410RB 54L850R0 54L851R0 54L852R0 54L850RR 54L851RR 54L852RR (Not Available) 54L851RB 54L852RB Middle Assembly Product Numbers Fixtures Right Side Only Fixtures Both Sides Middle Superstructure Product Numbers Width Without Fixtures Fixtures Right Side Only Fixtures Both Sides Without Fixtures Single-faced Style 48” (1219 mm) 60” (1219 mm) 72” (1219 mm) 554C403B 554C405B 554C409B 554C403BR 554C405BR 554C409BR (Not Available) 554C405BB 554C409BB 54L853B0 54L854B0 54L855B0 54L853BR 54L854BR 54L855BR (Not Available) 54L854BB 54L855BB Double-faced Style 48” (1219 mm) 60” (1219 mm) 72” (1219 mm) 554C404B 554C406B 554C410B 554C404BR 554C406BR 554C410BR (Not Available) 554C406BB 554C410BB 54L850B0 54L851B0 54L852B0 54L850BR 54L851BR 54L852BR (Not Available) 54L851BB 54L852BB Right-end Assembly Product Numbers Fixtures Right Side Only Fixtures Both Sides Right-end Superstructure Product Numbers Width Without Fixtures Fixtures Right Side Only Fixtures Both Sides Without Fixtures Single-faced Style 48” (1219 mm) 60” (1219 mm) 72” (1219 mm) 554C403L 554C405L 554C409L 554C403LR 554C405LR 554C409LR (Not Available) 554C405LB 554C409LB 54L853L0 54L854L0 54L855L0 54L853LR 54L854LR 54L855LR (Not Available) 54L854LB 54L855LB Double-faced Style 48” (1219 mm) 60” (1219 mm) 72” (1219 mm) 554C404L 554C406L 554C410L 554C404LR 554C406LR 554C410LR (Not Available) 554C406LB 554C410LB 54L850L0 54L851L0 54L852L0 54L850LR 54L851LR 54L852LR (Not Available) 54L851LB 54L852LB Assemblies includes work surface. Fixtures Right Side Only Fixtures Both Sides Superstructures do not include work surface. Order separately. 71 Horizon Stand-alone Assembly Product Numbers Thermo Scientific Hamilton Air Flow Products Horizon Dimensions and Operating Parameters Typical Front Views 7” (178 mm) 57.01” (1448 mm) 21.44” (545 mm) 18” 18” (457 mm) (457 mm) 48” (1219 mm) 28.44” (722 mm) End View – Double Unit 12” (305 mm) 18” 18” (457 mm) (457 mm) 34.8” (884 mm) 60” (1524 mm) 1.25” (32mm) 96.05” (2440 mm) 60” (1524 mm) 1.25” (32 mm) 96.05” (2440 mm) 60” (1524 mm) 96.05” (2440 mm) 36” (914 mm) 24” (610 mm) 96.25” (2445 mm) 1.25” (32 mm) 72” (1829 mm) Horizon 34.8” (884 mm) Horizon 21.44” 14.125” 21.44” (545 mm) (359 mm) (545 mm) 32.3” (820 mm) 60” (1524 mm) Horizon 48” (1219 mm) Horizon 34.8” (884mm) 64.6” (1641 mm) 25” (635 mm) 35” (889 mm) Exhaust Collar 35” (889 mm) 50” (1270 mm) Exhaust Collar 36” (914mm) 24” (610 mm) 96.25” (2445 mm) End Views 12” (305 mm) 60” (1524 mm) 18” 18” 18” 18” (457mm) (457mm) (457mm) (457mm) 72” (1829 mm) End View – Single Unit For applications against wall or end of island or peninsula. Operating Parameters Operating Parameters VAV (Variable Air Volume) CV (Constant Volume) 100 FPM @ 18” Sash Opening* Fume Hood Size 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) Configuration Singled-sided Double-sided Single-sided Double-sided Single-sided Double-sided Collar Size 4” x 30” (102 x 762 mm) 9” x 30” (229 x 762 mm) 4” x 30” (109 x 762 mm) 9” x 30” (229 x 762 mm) 4” x 30” (102 x 762 mm) 9” x 30” (229 x 762 mm) CFM SP 550 .15 1100 .25 700 .18 1400 .30 50 .21 1700 .35 For free-standing use, use a 3-sided U-shaped sink shroud in place of the fillers on each side. 34” opening for set up only. Operating position is an 18” opening. Fume Hood Size 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 100 FPM @ 18” Both sashes open 100 FPM @ 18” One sash open One sash closed Both sashes closed** 1100 720 340 1400 915 430 1700 1110 520 **Set to meet NFPA recommendations of 25 CFM per sq. ft. of interior work surface. n Sash tracking (versus sidewall sensing controls) are recommended when fume hood is applied to a VAV system. n Utilize only series 54LAFA1000 alarm. n Use 2 alarms on double-sided fume hood. Plumbing Coiled tubing is 1/4” O.D. copper for all services. Plumber required to route to the top or bottom of fume hood for final connection. A field connection is required from valve in the cabinet to the fixture. Shipping Fume hood ships knocked down. Electrical Electrician to connect wiring from junction box in cabinet to top of fume hood. 72 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products This page is intentionally blank. 73 Thermo Scientific Hamilton Air Flow Products PaceAire Restricted Bypass Designed for small working spaces and small budgets; ideally suited to schools, hospitals, clinics and small industrial laboratories. n Compact, lightweight, yet sturdy and efficient. n Light-duty fume hood; not for highly corrosive environments. n Optional two-speed integral blower provides operation at lower mode to conserve energy; also allows face velocity to be coordinated with a wider range of duct conditions. n Constructed of 18 gauge steel, double-walled and reinforced, yet light enough for easy installation. n Compact size fits on any standard laboratory bench top, yet provides large interior work area. n Full-view vertically rising sash made of 7/32” (6 mm) laminated safety glass with full-width recessed pull. n Fixed baffle position. n Steel liner with gloss white finish. n Does not include sidewall access panel. n Vapor-proof light fixture and black light switch/flush plate. n Fume hood is pre-wired for lights and blower (if ordered). n 36” (914 mm) wide. n UL 1805 classified n Description 54L51300 54L51200 With Blower Without Blower Blower Specifications Exhaust Outlet – 5-1/4” (133mm) x 8-3/8” (213mm) Speed – Low: 1140 RPM; High: 1725 RPM Horsepower – Low: 1/8; High: 1/4 Electrical – 115 VAC, 60 Hz Exhaust outlet location without blower Collar Size 36” (914 mm) 8” Diameter (203 mm) 23-3/4” (603 mm) High Speed Low Speed 100 FPM @ 28-1/2” 75 FPM @ 28-1/2” Sash Opening* Sash Opening* CFM SP CFM SP 657 .28 490 7-1/4” (184 mm) 8-3/8” (213 mm) 7-5/16” (186 mm) Exhaust Volumes Blower Fume Hood Size 36” (914 mm) 8-1/8” (206 mm) 8” Diameter 16-3/4” (203 mm) (426 mm) 5-1/4” (133 mm) Exhaust outlet location with blower Top View .19 7-5/16” (186 mm) 8-1/4” (210 mm) BK BL BS BD CH DK G1 G3 HG Black Blue Blue Slate Brown Burgundy Chameleon Dark Khaki Dove Grey Grey Slate Hunter Green IN KK PW PM PL PA SA SS SW Indigo Khaki Petal White Piedmont Green Platinum Purple Sand Sandstone Shell White Optional Fume Hood Back Panel – to enclose fume hood back when installed in open area. (Product number 54L51400) 74 28-1/2” (724 mm) Finish Color Choices – 32-5/8” (829 mm) 33” (838 mm) 36” (914 mm) Front View 41” (1041 mm) * See page 12 for operating instructions. 53” (1364 mm) Specialty Exhaust Systems Product Numbers Product No. 18-1/2” (470 mm) 23-3/4” (603 mm) End View www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Table Top Fume Hood These workstation enclosures provide containment of fumes. Reduced exposure levels have been verified via testing to ASHRAE 110 1995 guidelines. Workstations have been designed to provide maximum comfort and visibility. A baffle system at the rear of the enclosure provides flow patterns and containment levels comparable to laboratory fume hood. Perimeter flow on top, bottom, and sides of enclosure reduce turbulence and reverse flows typical in non-baffled enclosures. This enhanced air flow provides containment at lower face velocities (50 FPM). Units are applicable to balance applications, tissue trimming, pipetting, electronics, and arts lab procedures. Constructed of clear 1/4” thick acrylic for visibility. All edges are fused and polished to ensure maximum clarity and durability. Hinged access shield for setup and removal of apparatus. Exhaust outlets are 4” diameter on 60 cm and 90 cm models and 6” diameter on 120 cm models to minimize sound levels. Designed to be connected to new or existing exhaust system with flex-duct (order separately). Exhaust Collar 10-3/8” Hinge 2” 20” Specialty Exhaust Systems 12-1/4” Removable Baffle 8” 2” 23” Front View End View Table Top Fume Hood Product Number Width Exhaust Collar Size 50 FPM Face Velocity CFM Static Pressure 54L27200 23.6” (600 mm) 4” Diameter 66 .25” 54L27300 35.4” (900 mm) 4” Diameter 98 .45” 54L27400 47.2” (1200 mm) 6” Diameter 131 .35” Flex Duct Product Number 54L26100 54L26200 Diameter Length Material 4” Diameter 6” Diameter 96” 96” Polyethylene Polyethylene 75 Thermo Scientific Hamilton Air Flow Products Up-draft Table-top Fume Hood Canopy Fume Hood n Designed to collect and exhaust heat, steam and odors when mounted above hot plates, water baths or portable equipment n Equipped with baffles to maximize slot velocities and control fumes n Steel with reagent-resistant finish (Optional stainless steel; available with extended leadtime) n Four 48” (1219 mm) rods with coupler for additional ceiling height n Connecting ductwork not included n Exhaust collar is 2” (51 mm) high with 12” (305 mm) diameter, located on a center line 9” (229 mm) from back of fume hood n Available with extended lead-time n Designed for use with overhead exhaust system to provide maximum efficiency n Adjustable, positive-control baffles n Steel with chemical-resistant powdecoat finish, specify color n Exhaust collar 2” (51 mm) by 6” (152 mm) n 16” (406 mm) wide n 18” (457 mm) high Exhaust Volumes Depth Description CFM SP 54L27000 10” (254 mm) Single-face 200 .50 54L27100 20” (508 mm) Double-faced 400 .50 12” Diameter (305 mm) Down-draft Drip-panel Table-top Fume Hood n Specialty Exhaust Systems Designed for use with hinged front top panel to accommodate tall equipment n Steel with chemical-resistant powdercoat finish, specify color n Available with extended lead-time n Exhaust collar 2” (51 mm) by 20” (58 mm) n 21” (533 mm) wide n 22” (559 mm) high Exhaust Volumes 76 Product No. Depth Description CFM SP 54L27600 16-3/4” (425 mm) Single-face 200 .50 54L27700 29” (508 mm) Double-faced 400 .50 Width 36” (914 mm) Front View End View Product Numbers Product No. 554S8810 554S8820 554S8830 554S8840 554S8850 554S8860 9” (229 mm) 24” (610mm) 48” (1219 mm) Product No. Width 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) Exhaust Volumes Based on two sides open, fume hood 42” (1067 mm) off work surface. Fume Hood Size 50 FPM Through Each Open Face CFM SP 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 1050 1225 1400 1575 1750 1925 .17 .20 .30 .37 .45 .57 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products 4” Diameter Fume Removal System n Articulated joints incorporates gas spring cylinders and an ergonomic handle for precision adjustment to point of use. n Can be mounted from ceiling or wall. n 90L22100 Ceiling Mount Extractor Arm (90L22000 is similar) Articulated joints let you position arms exactly where you need them. n Mounts on counter top, wall or ceiling. n Use for spot ventilation applications. n Stay-put fitted central joints ensure that arm stays in place. n Extractor arms are brushed aluminum. n Elbows and all accessories are white. n Normal operating CFM is 50 to 75, the maximum is 100 but not recommended. n Static pressure is 2-1/4” at 75 CFM. Product No. Description 90L22000 3” diameter wall mount extractor arm, 41” (1041 mm) working radius 3” diameter ceiling mount extractor arm, 41” (1041 mm) working radius 8” (203 mm) diameter fume hood attachment, white aluminum Wall bracket, use with 90L22000 arm Ceiling bracket, 20” (58 mm), use with 90L22100 arm Ceiling bracket, 30” (762 mm), use with 90L22100 arm Ceiling bracket, 40” (1016 mm), use with 90L22100 arm 90L22100 90L22200 Fume Hood 90L22200 90L22300 90L22400 Wall Bracket 90L22500 90L22600 Ceiling Bracket 90L22700 Table Mount Extractor Arm 90L22700 90L22800 Table mount extractor arm, 35” (889 mm) Working radius Table bracket, white powdercoat finish, use with 90L22700 arm Designed to handle air volumes up to 235 cfm. n Armature extends 71” (1803 mm). n Use for table-top fume removal applications. n Stay-put fitted central joints ensure that arm stays in place. n Extractor arms are brushed aluminum with white polypropylene elbows. n Product No. Description 90L21500 4” diameter wall-mount arm 4” diameter ceiling-mount arm 90L21600 Fume Hood Attachment Fume Hood Attachment 90L21700 8” (203 mm) diameter natural aluminum 90L21900 14” (203 mm) diameter natural aluminum 90L21800 20” (58 mm) diameter opaque polypropylene Mounting Bracket 90L21200 Wall-mount bracket (pair) white powdercoat finish Wall Bracket 90L21300 Ceiling column – 20” (58 mm), white powdercoat finish 90L21400 Ceiling column – 40” (1016 mm), white powdercoat finish 90L22200 Fume Hood Ceiling Bracket Table Bracket 77 Specialty Exhaust Systems 3” Diameter Fume Removal System Thermo Scientific Hamilton Air Flow Products Forensics Cabinets Forensics cabinets feature ducted fuming chambers to provide protection for laboratory personnel from dangerous fumes and odors generated during the treatment of evidentiary materials. Forensics cabinets are ideal for print analysis and fuming processes using cyanoacrylates. The cabinets contain individually vented chambers of various sizes designed to minimize overall airflow. Reduced airflow enhances the effectiveness of the fuming process and minimizes fuming time. Forensics cabinets are available in bench and floor mounted configurations. Common Features: n Three chambers, each chamber can be operated independently. n Each chamber features a vapor-proof incandescent light fixture. n Chamber doors include padlock hasp to secure evidence during fuming procedure. n Hanging rods are provided in each chamber, shelves are provided in the large chamber of the floor-mounted unit. n Electrical outlets with power cord pass through for routing hot plate cords are provided for each chamber. Specialty Exhaust Systems n Plastic laminate construction with 45 lb. density particle board core, doweled joinery, Wilsonart® Chemsurf® chemical resistant plastic laminate interior and high pressure plastic laminate exterior. n Unit is pre-wired to central junction box located on top of cabinet. Bench Top Unit n Bench top unit provides a total of 13 cubic feet of containment area. n Energy efficient – exhausts only 14 cubic feet of air per minute. 78 Floor Mounted Unit n Floor mounted unit provides a total of 31 cubic feet of containment area. n Energy efficient – exhausts only 31 cubic feet of air per minute. www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Ordering Information Vent outlet extends 3-1/2” above top of cabinet at rear. Counter Top Unit – Grey Plastic Laminate Exterior Product Number 950P200GY Capacity Exhaust Volume Exhaust Collar Diameter Weight 13 Cubic Feet 14 CFM 1.5” I.D. 230 lbs. 48” 15.75” 42” Vent outlet extends 4” above top of cabinet at rear. Floor Mounted Unit – Grey Plastic Laminate Exterior Product Number 950P201GY Capacity Exhaust Volume Exhaust Collar Diameter Weight 31 Cubic Feet 31 CFM 2” I.D. 395 lbs. Product No. Width Depth Height Weight 148P732GY 42” 22” 35” 155 lbs. Specialty Exhaust Systems Base Cabinet – Grey Plastic Laminate Exterior Counter Top – Black Chemsurf Product No. Width Depth Height Weight 20L24430 43” 24” 1” 55 lbs. Shelves Product No. For Cabinet Style Compartment Location 950P2020 950P2030 950P2040 950P2050 Counter Top Floor Mounted Floor Mounted Floor Mounted Right Upper Left Lower Left Right Upper Left Right Lower Left Specifications Unit shall consist of three separate fuming chambers of various sizes to allow separate fuming processes concurrently. Each chamber shall be dampered, lockable, and glazed. Chambers shall have v-strip sealed doors to minimize airflow during fuming process. Each compartment shall include a vapor-proof incandescent light and access to 110 volt AC receptacles. Construction shall be 45 lb. density particle board core with doweled joinery. Wilsonart Chemsurf chemical resistant plastic laminate interior and highpressure plastic laminate exterior. Each unit shall contain a test report verifying proper containment with the chamber closed. Test shall be based on ASHRAE 110 1995 methodology. Containment must be 4.0 AM 0.05 PPM or better. 79 Thermo Scientific Hamilton Air Flow Products Vented Chemical Storage Cabinet n Designed for storage of large volumes of non-flammable chemicals, reagents and samples during processing. Chemical, safety containers and samples can be vertically stacked while containing any noxious fumes that otherwise would enter the laboratory. n Upper compartment has five half-width adjustable perforated shelves and horizontal sliding framed glass doors with louvers. n Lower compartment has one heavy-duty perforated pull-out shelf and vertical rising framed glass sash with louvers. Each pull-out shelf can support up to 440 lbs Optional pull-out shelves can be purchased and field installed. Lower cavity can support up to four shelf assemblies n Upper compartment is 51-1/2” (1302 mm) high and lower compartment is 43-1/2” (1103 mm) high. n Overall n Duct dimensions: 99” (2515 mm) high x 48” (1219 mm) x 28-3/4” (730 mm) deep. manifold and shut-off damper is provided and installed by others Product No. 950S1120 950S1160 Complete Assembly Optional Pull-out Shelf Assembly Specialty Exhaust Systems Exhaust Parameters Exhaust Vents One One Two Size 2-1/2” I.D. 2-7/8” O.D. 2-1/2” I.D. 2-7/8” O.D. 2-1/2” I.D 2-7/8” O.D. Location Upper left cavity Upper right cavity Lower cavity Cubic Feet Per Minute Static Pressure 10 CFM per vent .15 (Expressed in inches of water) 24” 3-7/8” 4-1/2” 28-3/4” 4-1/2” Four outlets 2-7/8” O.D. 99” above floor 48” Roughing-in Diagram 80 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products captair® Flex™ Ductless Fume Hood n Easily movable. Ductless filtration system. n Use for handling of liquid, gaseous and solid chemicals. n Flex™ technology: adaptable modular filtration column. n Solid and liquid handlings. n Enclosure dimensions from 31-1/2” (800 mm) to 63” (1600 mm). n Very low energy consumption. n Easy installation and relocation. n Reduces infrastructure, setup and running costs. n Compliant with NF X 15-221 2009 standard. [Class 2] n Tested according to the ASHRAE 110 1995 standard. n No emission of harmful pollutants released into the atmosphere. n White exterior framing. n Optional backup filter* Fan module Specialty Exhaust Systems When placing a captair fume hood order: n Order work surfaces separately as listed on page 82. n Order filters separately as listed on page 82. n Order base cabinets separately, see pages 105-108. n Call Erlab, Inc. at 1.800.964.4434 for assistance in determining the appropriate filter. * To meet AFNOR Class 1, optional filter is required. Cover Activiated carbon filter for solvents and acids Ceiling Control panel Adaptable Modular Filtration Column Acrylic enclosure Service port Ergonomic openings Optional work surface and spill tray (Steel with laminated tempered glass work surface) 81 Thermo Scientific Hamilton Air Flow Products 30 15/16'' 30-15/16” 23 1/4'' 23-1/4” 30 15/16'' 30-15/16” 31-1/2” 52 5/8'' maxi 52-5/8” max *52-5/8” * 52 5/8'' max 23 1/4'' 23-1/4” 45 2/8'' mini 45-1/4” min 35” 35'' 23 1/4'' 23-1/4” 2 14/16'' 1-3/16” 1 3/16'' 25 3/16'' 25-3/16” 2' 7/16'' 28-7/16” 54L17000 23-1/4” * 45 2/8'' min *45-1/4” 35” 2 14/16'' 23-1/4” *45-1/4” min * 30-15/16” 63'' 63” * *52-5/8” max * *45-1/4” min 35” 6 3/4'' 6 3/4'' 6-3/4” 6 3/4'' 6-3/4” 2-14/16” 7 1/2'' 13-1/16” 7-1/2” 13 1/16'' 7 1/2'' 13-1/16” 7-1/2” 13 1/16'' Specialty Exhaust Systems 10'' 10” 1-3/16” 30 2/8'' 30-1/4” 25-3/16” 28-7/16” 10'' 10” 10” 10'' 38'' 38” 1-3/16” 25-3/16” 28-7/16” 6 3/4'' 6-3/4” 2-14/16” 48 13/16'' 48-13/16” 6-3/4” 13 1/16'' 7 1/2'' 13-1/16” 7-1/2” External dimensions 10'' 10” 1-3/16” 25-3/16” 28-7/16” Dimensions Product No. 61-1/2” 54L17300 23-1/4” 35” 13 1/16'' 2-14/16” 7 1/2'' 13-1/16” 7-1/2” 10” 1 3/16'' 1-3/16” 25 3/16'' 25-3/16” 2 7/16'' 28-7/16” 48-13/16” 50 3/16'' 50-3/16” *52-5/8” max *42-1/4” min 6-3/4” 13-1/16” 7-1/2” 10” 54L17200 30-15/16” 35” 2 14/16'' 1-3/16” 1 3/16'' 25 3/16'' 25-3/16” 2 7/16'' 28-7/16” 38” 39 3/8'' 39-3/8” *52-5/8” max * 6-3/4” 13-1/16” 7-1/2” 2-14/16” 10” 54L17100 31 1/2" 31-1/2” 30-15/16” * 52 5/8'' *52-5/8” max 35'' 6-3/4” 2-14/16” 13-1/16” 7-1/2” 10” 1-3/16” 1 3/16'' 25 3/16'' 25-3/16” 30-1/4” 2 7/16'' 28-7/16” 63” 23 1/4'' 23-1/4” 35” 6-3/4” 2-14/16” 13-1/16” 7-1/2” 2-14/16” 2 14/16'' 30 15/16'' 30-15/16” 52 5/8'' *52-5/8” max 45 2/8'' min *42-1/4” 35'' 35” -1/4” min 50-3/16” *45-1/4” * 45 2/8'' min 35'' -5/8” max 30 15/16'' 30-15/16” 39-3/8” 61 1/2'' 61-1/2” Work Surfaces (optional) Internal dimensions – without work surface Product No. Width Depth Height Width Depth Height 54L17000 31-1/2” (800 mm) 28-7/16” (722 mm) 45-1/4” (1149 mm) min. 52-5/8” (1337 mm) max 30-1/4” (768 mm) 23-1/4” (591 mm) 35” (889 mm) 54L17900 54L17100 39-3/8” (1000 mm) 28-7/16” (722 mm) 45-1/4” (1149 mm) min. 52-5/8” (1337 mm) max 38” (965 mm) 23-1/4” (591 mm) 35” (889 mm) 54L18000 54L17200 50-3/16” (1275 mm) 28-7/16” (722 mm) 45-1/4” (1149 mm) min. 52-5/8” (1337 mm) max 48-13/16” (1240 mm) 23-1/4” (591 mm) 35” (889 mm) 54L18100 54L17300 63” (1600 mm) 28-7/16” (722 mm) 45-1/4” (1149 mm) min. 52-5/8” (1337 mm) max 61-1/2” (1562 mm) 23-1/4” (591 mm) 35” (889 mm) 54L18200 Standard Equipment Specifications Number of columns 1 Air flow meter Permanent air face velocity monitoring system Number of fans (IP44) 1 Flow monitor Permanent ventilation control device according to EN 14175-2:2003 standard Processed air flow 135 CFM Sampling port For filter saturation detection (N/A if Molecode S installed) Programmable timer Timer – 60 hours setting by default according to NFX 15 211:2009 standard Air velocity at the openings 79 FPM to 118 FPM in working position Voltage/Frequency Total power consumption 45 watts (without lighting) Amperage 1.6 AMP Sound level Metallic parts Energy ports For the passage of cables Chemical Listing List of approved chemicals 85-260 V / 50-60 Hz Filters (order separetely) Product No. 52 dbA Anti-corrosion metallic alloy protected by a white thermo-hardened anti-acid polymer coating Side and front panels 3/16” (5 mm) thick acrylic Filtrations module Polypropylene Compliance to Standards 54L17400 For organic vapors n ANSI/ASHRAE 110 1995 – USA 54L17500 For organic vapors + acid vapors n BS 7258 – England 54L17600 For formaldehyde vapors 54L17700 For ammonia vapors 54L17800 H14 HEPA Filter for powders n AFNOR NF X 15-211 2009 – France n CSA Z316.5 – Canada n CE Marketing n NF P.92.507 (Acrylic part) n EN 1822 1998 (HI4 HEPA filter) 82 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products This page is intentionally blank. 83 Thermo Scientific Hamilton Air Flow Products Thermo Scientific 1300 Series A2 Class II, Type A2 Biological Safety Cabinets The 1300 Series portfolio of products meets the highest quality and safety standards, and is fully-compliant with NSF/ANSI 49 for Class II biological safety cabinets. Good for You, Good for the Environment Laboratories today are facing new challenges. Safety and reliability continue to be paramount. Yet, there is growing need for improved energy efficiency, simpler operation and less maintenance. Thermo Scientific 1300 Series A2 Class II, Type A2 biological safety cabinets provide best-in-class safety, ergonomics and energy efficiency for today’s most laboratory applications. Maximized Energy Efficiency • The 1300 Series A2 features advancements in brushless DC motor technology for dramatically improved energy efficiency, safety performance and reliability. • Night-set-back mode saves energy while maintaining a clean work area. When the front sash is closed, the intelligent speed control automatically reduces blower speed to 30%, extending HEPA filter life and ensuring a sterile working environment even when the cabinet is not in use. Model shown: 4’ 1300 Series A2 biological safety cabinet with one-piece stainless steel interior and optional electric stand. Independent Safety Systems for Unmatched Security Biological Safety Cabinets SmartFlow™ maintains a safe working environment. The 1300 Series A2 employs a unique airflow system that raises safety and containment to a new level. Independent supply and exhaust blowers automate balancing of downflow and inflow/exhaust velocities to ensure continuous safe working conditions. Our smart DC motors monitor and control fan speed in real-time to maintain user protection at the access opening, even as the filters load or the line voltage fluctuates. Digital Airflow Verification (DAVe) validates product and personnel protection. Independent pressure sensors detect changes in pressure across the exhaust and downflow plenums. An alarm signals when a 20% change in inflow/exhaust or downflow occurs to alert the user if safety is compromised. Airflow velocities are displayed on the control panel for monitoring and recording. 84 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Ergonomic Design Enhances Safety SmartClean™ Window Design reduces risk of sample contamination. The patented window design easily lowers for thorough cleaning of the window's inner surface. This unique design protects the operator by maintaining inflow even when the window is lowered. Additional Ergonomic Features Include: • Sloped Front – Cabinet front is sloped 10° for enhanced comfort and reduced operator fatigue. • Reduced Noise Level – Lower noise level enhances the attention and allows user to focus on work without distraction. • Spacious Work Area – Large, unobstructed work surface increases productivity and safety. Ordering Information Specifications and Order Information 4’ models 6’ models Standard Model Coated interior wall, cabinet only BIO1355 BIO1357 Standard Package Includes coated interior cabinet walls, manual adjustable height stand, factory installed UV light, and one set of armrests BIO1385 BIO1387 Stainless Steel Model One-piece stainless steel interior, cabinet only BIO1345 BIO1347 Includes stainless steel interior cabinet walls, Stainless Steel Package manual adjustable height stand, factory installed UV light, and one set of armrests BIO1375 BIO1377 120V, 60Hz 120V, 60Hz Electrical Requirements for Standard and Stainless Steel Dimensions Exterior Dimensions H x W x D inches (mm) 61.8 x 51.2 x 31.5 (1568 x 1300 x 800) 61.8 x 74.8 x 31.5 (1568 x 1900 x 800) Interior Dimensions H x W x D inches (mm)* 30.7 x 47.2 x 18.3 (780 x 1200 x 465) 30.7 x 70.9 x 18.3 (780 x 1800 x 465) Working Height of Front Window inches (mm) 10 (254) 10 (254) Maximum Opening Height of Front Window inches (mm) 21 (535) 21 (535) Shipping Dimensions H x W x D inches (mm) Weight 68.1 x 55.6 x 36.4 (1730 x 1410 x 925) 68.1 x 79.1 x 36.4 (1730 x 2010 x 925) Net Weight lbs (kg) 375 (170) 507 (230) Shipping Weight lbs (kg) 430 (195) 584 (265) Maximum Load of One-piece Work Tray lbs (kg) 110 (50) 110 (50) A variety of options and accessories are also available. Contact a Thermo Fisher Scientific sales representative for more details. 85 Biological Safety Cabinets Thermo Scientific 1300 Series A2 Class II, Type A2 Biological Safety Cabinets Thermo Scientific Hamilton Air Flow Products Thermo Scientific 1300 Series B2 Class II, Type B2 Total Exhaust Biological Safety Cabinets Simplifying Your Safety Decisions Class II, Type B2 biological safety cabinets are built for applications that require working with greater than minute quantities of volatile toxic chemicals and radionuclides, or the aseptic processing of hazardous drugs. The Thermo Scientific 1300 Series B2 is the most advanced Class II, Type B2 biological safety cabinet available – with advanced ergonomics and airflow design. • An auto compensation feature allows the safe use of optional downflow air prefilters. Automatic adjustment of downflow velocity during HEPA filter loading provides added product protection. • Timed UV light option reduces risk of sample contamination and lowers bulb replacement costs. • 10˚ sloped window for ergonomic posture reduces strain and fatigue associated with long working hours. • Convenient display lets you see the cabinet is operating safely while you are working. • The efficiency of the state-of-the-art DC motor results in significantly reduced energy consumption and cost savings. Model shown: 4' 1300 Series B2 total exhaust biological safety cabinet. Ordering Information Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinets Specifications Biological Safety Cabinets Model Coated interior wall, cabinet only With factory installed UV light Electrical Receptacles Damper Dimensions Exterior Dimensions H x W x D inches (mm) Interior Dimensions H x W x D inches (mm) (Work area is taller in front, shorter in back) 4’ models 6’ models BIO1310 BIO1360 BIO1311 BIO1361 115V, 50/60 Hz 230V, 50/60 Hz 230V, 50/60 Hz 115V, 50/60 Hz 230V, 50/60 Hz 230V, 50/60 Hz US China/Australia US US China/Australia US 10-inch diamter air-tight damper included 71.5 x 54.3 x 31.6 (1816 x 1379 x 803) 71.5 x 78 x 31.6 (1816 x 1981 x 803) 25.7 x 29.2 x 48.5 x 25.5 (653-742 x 1232 x 648) 25.7 x 29.2 x 72.5 x 25.5 (653-742 x 1841 x 648) 8 (203) 8 (203) Maximum Opening Height of Front Window inches (mm) 21.75 (552) 21.75 (552) Work Surface Area square inches (sq m) 854 (0.55) 1275 (0.82) 81 x 72 x 44 (2057 x 1829 x 1118) 81 x 86 x 44 (2057 x 2184 x 1118) Working Height of Front Window inches (mm) Shipping Dimensions H x W x D inches (mm) Options and accessories are also available. Contact a Thermo Fisher Scientific sales representative for more details. 86 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products 1300 Series A2 1300 Series B2 Choose the Best Model for Your Laboratoy The Thermo Scientific 1300 Series A2 and B2 The Thermo Scientific 1300 Series family of products address every common use of the Class II biological safety cabinet. By selecting the 1300 Series A2, the 1300 Series A2 with a thimble exhaust, or the 1300 Series B2 biological safety cabinet, your lab will meet all applicable recommendations from NSF/ANSI 49 for volatile toxic chemicals and radionuclides, and the National Institute for Occupational Safety and Health (NIOSH) Alert on Hazardous Drug Preparation for Class II biological safety cabinets. Exhaust technology recommendation for specific work applications. Work Application Using: 1300 Series A2 vented to the room 1300 Series A2 with thimble exhaust 1300 Series B2 with direct duct ”total exhaust” Recommended Exceeds Requirement Exceeds Requirement 1 Particulate contaminate and hazards including biological agents (viruses and bacterial) at Biosafety Levels 1, 2, 3 or in BSK4 suit laboratories 2 Agents in row 1 and/or minute quantities of volatile toxic chemicals and tracer amounts of radionuclides required as an adjunct to microbiological studies No Recommended Exceeds Requirement 3 Agents in rows 1 and/or more than minute quantities of volatile toxic chemicals and tracer amounts of radionuclides, required as an adjunct to microbiological studies No No Recommended 4 Agents in row 1 and/or in hazardous drug preparation No No Recommended Vunerability of system to exhaust variation None Minimal Significant Additional annual cost of required exhaust None $1,900 to $2,900 annually* $3,000 to $4,500 annually* * Cost estimates are based on the required exhaust volume for the cabinet type, and assume a cost of $4.50 per cfm per year for replacement air. E. Mills, D. Sartor / Energy 30 (2005) 1859-1864 87 Biological Safety Cabinets Biological Safety Cabinet Selection Guide Thermo Scientific Hamilton Air Flow Products Front-loaded Service Valves Common features: Fixture has forged brass valve body, black washer and colorcoded outlet to match index button. n Parts exposed in fume hood have acid- and solvent-resistant epoxy finish, color-coded to match index button (unless otherwise noted). n Goosenecks and outlets have removable serrated hose tip. n 3/8” (10 mm) IPS coupling brazed to gooseneck styles for accessory attachment. n Shipped loose for field installation only. n All standard valves are CSA approved. n Remote Control Service Valves n Two front-loaded service valves for hot and cold water mixing n Forged brass four-arm handle with clear plastic-coated chrome n Colored plastic index disc n Max. working pressure is 80 PSI n Requires 1-1/4” (32 mm) diameter hole in panel Product No. Service 32L26300 Hot and cold water n Front-loaded single service valve Forged brass four-arm handle with clear plastic-coated chrome n Colored plastic index disc n Max. working pressure is 80 PSI n Requires 1-1/4” (32 mm) diameter hole in panel n n Single service remote control valve Max. working pressure is 80 PSI n Valves with stem for use with outlet, with hose connector, page 87 n Product No. Service 32L20000 32L20001 Cold water with stem Distilled water with stem n Single service remote control valve n Max. working pressure is 125 PSI n Valves for oxygen and nitrogen are cleaned for pure gas service Product No. Service 32L20200 Gas, air, vacuum with stem Oxygen, nitrogen with stem 32L20300 n n Single service remote control valve Max. working pressure is 20 PSI Product No. Service 32L20400 Steam with stem Product No. Service 32L26400 32L26500 Hot or cold water Distilled water n Front-loaded single service valve Forged brass four-arm handle with clear plastic-coated chrome n Colored plastic index disc n Max. working pressure is 125 PSI n Requires 1-1/4” (32 mm) diameter hole in panel n Product No. Service 32L26600 32L26800 Gas, air, vacuum Oxygen, nitrogen n Front-loaded single service valve Four-arm heat resistant black handle n Black plastic index disc n Max. working pressure is 20 PSI n Requires 1-1/4” (32 mm) diameter hole in panel n Product No. Service 32L26700 Steam Remote Control Ball Valve Assembly n Remote control service valve is factory assembled, includes guide plate, rod and handle n Forged brass black nylon lever handle, for chrome-plated add suffix ”FH” n Colored plastic index disc n Max. working pressure is 75 PSI n Suitable for water and gas services Fixtures Product No. 32L20600 32L20700 88 Right Left Rod and Handle Assembly for Service Valves n Rod and handle assembly for remote control service valve n Black 3/8” (10 mm) diameter aluminum rod n Black nylon four-arm handle with color-coded index button n Requires field cut to fit Product No. Rod Length 32L24500 32L24600 32L24700 7-9/16” 11-1/2” 31-5/16” www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Gooseneck Outlets Common features: n Fixture has forged brass valve body, black washer and color-coded outlet to match index button. n Parts exposed in fume hood have acid- and solvent-resistant epoxy finish, color-coded to match index button (unless otherwise noted). n Goosenecks and outlets have removable serrated hose tip. n 3/8” (10 mm) IPS coupling brazed to gooseneck styles for accessory attachment. n Shipped loose for field installation only. n All standard valves are CSA approved. n Low profile gooseneck with turret and removable ten-serration hose end n Turret supplied with locknut, ferrule and compression nut n 1/2” I.D. compression inlet n Rigid/swing adapter n Color: green Product No. 32L26900 32L27000 Outlet with Hose Connector 4” spread gooseneck 6” spread gooseneck n Powdercoated brass turret and removable ten-serration hose connector positioned at 90 degrees n Turret supplied with locknut, ferrule and compression fitting for 3/8” copper tubing n 1/2” I.D. compression inlet n For use with remote control service valves with stems Product No. Service 32L25300 32L25500 Cold Water Hot Water n Gooseneck with vacuum breaker, turret and removable ten-serration hose end n Vandal resistant turret supplied with locknut n 3/8” NPS inlet * Vacuum breaker is not recommended inside fume hood per NFPA Product No. 32L27100 6” spread gooseneck n Powdercoated brass turret and removable ten-serration hose connector positioned at 90 degrees n Tin-lined connector and turret n Turret supplied with locknut, ferrule and compression fitting for 3/8” copper tubing n 1/2” I.D. compression inlet Product No. Service 32L25400 Distilled Water Vacuum Breakers for Fume Hood n Brass vacuum breaker with no finish For use with hidden applications n 3/8” IPS female inlet and outlet n Product No. 32L27400 n Product No. Service 32L24800 32L24900 32L25000 32L25100 32L25200 Generic (color: black) Air Vacuum Gas Nitrogen (Cleaned for pure gas service) Oxygen (Cleaned for pure gas service) 32L25600 n Brass vacuum breaker assembly with polished chrome finish n Union connection n 1/2” IPS female inlet and outlet Product No. 32L27500 n Brass vacuum breaker assembly with polished chrome finish n To be used with Concept and Horizon Fume Hood n Chrome plated locknuts n 3/8” IPS female inlet and outlet Fixtures Powdercoated brass turret and removable ten-serration hose connector positioned at a 30 degree angle n Turret supplied with locknut, ferrule and compression nut n 1/2” I.D. compression inlet Product No. 32L27600 89 Thermo Scientific Hamilton Air Flow Products Remote Control Deck-mounted Service Fixtures (continued) Common Features: n Fixture has forged brass valve body, black washer and color-coded outlet to match index button. n Parts exposed in fume hood have acid- and solvent-resistant epoxy finish, color-coded to match index button (unless otherwise noted). n Goosenecks and outlets have removable serrated hose tip. 3/8” (10 mm) IPS coupling brazed to gooseneck styles for accessory attachment. n Shipped loose for field installation only. n All standard valves are CSA approved. n n Single-service gooseneck with vacuum breaker n Washer and lock nut for deck mounting on 1-1/4” (32 mm) work surface n For use with cupsink installed front or back n H0 suffix indicates hot water n C0 suffix indicates cold water n Deck-mounted single-service valve for air, gases or vacuum n Mounting hardware for 1-1/4” (32 mm) work surface Product No. Service Top Depth Mount Location 30L567G0 30L567A0 30L567V0 Gas Air Vacuum 36” (914 mm) 36” (914 mm) 36” (914 mm) Wood Base Cabinet Wood Base Cabinet Wood Base Cabinet 30L568G0 30L568A0 30L568V0 Gas Air Vacuum 30” (762 mm) 30” (762 mm) 30” (762 mm) Table Frame, Wood/Steel Table Frame, Wood/Steel Table Frame, Wood/Steel 30L569G0 30L569A0 30L569V0 Gas Air Vacuum 36” (914 mm) 36” (914 mm) 36” (914 mm) Table Frame, Wood/Steel Table Frame, Wood/Steel Table Frame, Wood/Steel 30L570G0 30L570A0 30L570V0 Gas Air Vacuum 30” (762 mm) 30” (762 mm) 30” (762 mm) Steel Base Cabinet Steel Base Cabinet Steel Base Cabinet 30L571G0 30L571A0 30L571V0 Gas Air Vacuum 36” (914 mm) 36” (914 mm) 36” (914 mm) Steel Base Cabinet Steel Base Cabinet Steel Base Cabinet 30L572G0 30L572A0 30L572V0 Gas Air Vacuum 30” (762 mm) 30” (762 mm) 30” (762 mm) Wood Base Cabinet Wood Base Cabinet Wood Base Cabinet * Vacuum breaker is not recommended inside fume hood per NFPA Product No. Top Depth 32L622H0 32L622CO 32L623HO 32L623CO 32L624HO 32L624CO 32L625HO 32L625CO 32L626HO 32L626CO 32L628HO 32L628CO 36” 36” 30” 30” 36” 36” 30” 30” 36” 36” 30” 30” Mount Location (914 mm) (914 mm) (762 mm) (762 mm) (914 mm) (914 mm) (762 mm) (762 mm) (914 mm) (914 mm) (762 mm) (762 mm) Wood Base Cabinet Wood Base Cabinet Table Frame, Steel and Wood Table Frame, Steel and Wood Table Frame, Steel and Wood Table Frame, Steel and Wood Steel Base Cabinet Steel Base Cabinet Steel Base Cabinet Steel Base Cabinet Wood Base Cabinet Wood Base Cabinet n n Single-service gooseneck n Washer and lock nut for deck mounting on 1-1/4” (32 mm) work surface n For use with cupsink installed front or back n ”H0” suffix indicates hot water n ”C0” suffix indicates cold water Single-service color-coded gooseneck n For use with cupsink installed front or back n Sidewall mounted n Add HW (hot water) or CW (cold water) to end of Product Number for service required n Extended lead time Product No. CA32L552 Product No. Fixtures 32L617H0 32L617C0 32L618H0 32L618C0 32L619H0 32L619C0 32L620H0 32L620C0 32L621H0 32L621C0 32L627H0 32L627C0 90 Top Depth 36” (914 mm) 36” (914 mm) 30” (762 mm) 30” (762 mm) 36” (914 mm) 36” (914 mm) 30” (762 mm) 30” (762 mm) 36” (914 mm) 36” (914 mm) 30” (762 mm) 30” (762 mm) Mount Location Wood Base Cabinet Wood Base Cabinet Table Frame, Steel and Wood Table Frame, Steel and Wood Table Frame, Steel and Wood Table Frame, Steel and Wood Steel Base Cabinet Steel Base Cabinet Wood Base Cabinet Wood Base Cabinet Wood Base Cabinet Wood Base Cabinet www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Common Features: n Fixture has forged brass valve body, black washer and color-coded outlet to match index button. n Parts exposed in fume hood have acid- and solvent-resistant epoxy finish, color-coded to match index button (unless otherwise noted). n Black nylon four-arm handle with nylon color-coded index button. n Removable serrated tip. n 3/8” (10 mm) IPS coupling brazed to gooseneck styles for accessory attachment. Installation requirements: n Requires 1” (254 mm) mounting hole on interior end panels. n Requires 9/16” (143 mm) mounting hole at front posts. Remote Control Water Faucets (continued) n General mixing faucet n Turret base with serrated hose end n Flat mounting flange for wall mount n For use with cupsink installed front or back n ”WA” suffix indicates front fixtures n ”00” suffix indicates rear fixtures Fume Hood Type Auxiliary Air Auxiliary Air Bypass, VAV, Radioisotope Bypass, VAV, Radioisotope Front Back Front Back 32L567WA 32L60600 Bypass & VAV Floor-mounted Bypass & VAV Floor-mounted Front Back 32L568WA 32L60700 Auxiliary Air Floor-mounted Auxiliary Air Floor-mounted Front Back n Single-service water valve Turret base with serrated hose end n Flat mounting flange for wall mount n For working pressure up to 80 PSI n For use with cupsink installed at front n Distilled water fixtures are tin-lined n Product No. Service Fume Hood Type Fixture Location 32L551CW 32L551HW 32L576DW 32L62900 Cold Water Hot Water Distilled Water Steam Auxiliary Air Auxiliary Air Auxiliary Air Auxiliary Air Front Front Front Front 32L552CW 32L552HW 32L577DW 32L63000 Cold Water Hot Water Distilled Water Steam Bypass, VAV, Radioisotope Bypass, VAV, Radioisotope Bypass, VAV, Radioisotope Bypass, VAV, Radioisotope Front Front Front Front 32L554CW 32L554HW 32L579DW 32L63100 Cold Water Hot Water Distilled Water Steam Bypass & VAV Floor-mounted Bypass & VAV Floor-mounted Bypass & VAV Floor-mounted Bypass & VAV Floor-mounted Front Front Front Front 32L555CW 32L555HW 32L580DW 32L63200 Cold Water Hot Water Distilled Water Steam Auxiliary Air Floor-mounted Auxiliary Air Floor-mounted Auxiliary Air Floor-mounted Auxiliary Air Floor-mounted Front Front Front Front Fixture Location n Single-service water valve Turret base with serrated hose end n Flat mounting flange for wall mount n For working pressure up to 80 PSI n For use with rear mounted cupsink n Product No. Service Fume Hood Type 32L595CW 32L595HW 32L596CW 32L596HW 32L597CW 32L597HW 32L598CW 32L598HW Cold Water Hot Water Cold Water Hot Water Cold Water Hot Water Cold Water Hot Water Auxiliary Air Auxiliary Air Bypass, VAV, Radioisotope Bypass, VAV, Radioisotope Bypass & VAV Floor-mounted Bypass & VAV Floor-mounted Auxiliary Air Floor-mounted Auxiliary Air Floor-mounted n Single-service color-coded gooseneck n Sidewall mounted n For cold water service n For use with front mounted cupsink Product No. Fume Hood Type 32L688CW 32L689CW 32L690CW 32L691CW Auxiliary Air Bench/High-line Constant Volume/Restricted Bypass Bench/High-line Constant Volume/Restricted Bypass Floor-mounted Auxiliary Air Floor-mounted n Panel-mounted single-service valve for air, gases or vacuum n Color-coded outlet to match index button, with black washer Fixture Location Back Back Back Back Back Back Back Back Single-service color-coded gooseneck n Sidewall mounted n For cold water service n For use with rear mounted cupsink n Product No. Fume Hood Type 32L692CW 32L693CW 32L694CW 32L695CW Auxiliary Air Bench/High-line Constant Volume/Restricted Bypass Bench/High-line Constant Volume/Restricted Bypass Floor-mounted Auxiliary Air Floor-mounted Product No. Service Fume Hood Type 30L496GW 30L496AW 30L496VW 30L57300 30L57700 Gas Air Vacuum Nitrogen Oxygen Auxiliary Air Auxiliary Air Auxiliary Air Auxiliary Air Auxiliary Air 30L497GW 30L497AW 30L497VW 30L57400 30L57800 Gas Air Vacuum Nitrogen Oxygen Bypass, R.B., Radioisotope Bypass, R.B., Radioisotope Bypass, R.B., Radioisotope Bypass, R.B., Radioisotope Bypass, R.B., Radioisotope 30L499GW 30L499AW 30L499VW 30L57500 30L57900 Gas Air Vacuum Nitrogen Oxygen Bypass & R.B. Floor-mounted Bypass & R.B. Floor-mounted Bypass & R.B. Floor-mounted Bypass & R.B. Floor-mounted Bypass & R.B. Floor-mounted 30L500GW 30L500AW 30L500VW 30L57600 30L58000 Gas Air Vacuum Nitrogen Oxygen Auxiliary Air Floor-mounted Auxiliary Air Floor-mounted Auxiliary Air Floor-mounted Auxiliary Air Floor-mounted Auxiliary Air Floor-mounted 91 Fixtures Product No. 32L564WA 32L60400 32L565WA 32L60500 Remote Control Water Faucets (continued) Thermo Scientific Hamilton Air Flow Products Common features: n Fixture has forged brass valve body, black washer and color-coded outlet to match index button. n Parts exposed in fume hood have acid- and solvent-resistant epoxy finish, color-coded to match index button (unless otherwise noted). n Black nylon four-arm handle with nylon color-coded index button. n Removable serrated tip. Can be installed on right or left side. n For use with cupsink installed front or back. n Installation requirements: n Requires 1” (254 mm) mounting hole at interior end panels. n Requires 9/16” (143 mm) mounting hole at front posts. Remote Control Water Faucets with Vacuum Breakers n Single-service assembly Vacuum breaker n Front outlet fixture n Product No. Fume Hood Type 32L675CW 32L676CW Auxiliary Air Bypass, Restricted Bypass, Radioisotope Floor-mounted, Bypass, Restricted Bypass Floor-mounted, Auxiliary Air 32L677CW 32L678CW n Assembly for hot and cold water Vacuum breaker n Front outlet fixture n Product No. Fume Hood Type 32L66800 32L66900 Auxiliary Air Bypass, Restricted Bypass, Radioisotope Floor-mounted, Auxiliary Air 32L67000 n n n n Single-service assembly Vacuum breaker n Rear outlet fixture Assembly for hot and cold water Vacuum breaker n Rear outlet fixture Product No. Fume Hood Type Product No. Fume Hood Type 32L663CW 32L664CW Auxiliary Air Bypass, Restricted Bypass, Radioisotope Floor-mounted, Bypass, Restricted Bypass Floor-mounted, Auxiliary Air Perchloric Acid 32L67100 32L67200 Auxiliary Air Bypass, Restricted Bypass, Radioisotope 32L665CW 32L666CW 32L616CW n Single-service assembly Vacuum breaker n Rear outlet fixture n Product No. Fume Hood Type 32L925CW 32L926CW VAV Floor-mounted Vectrol Floor-mounted n Single-service assembly Top-mount front vacuum breaker n Front outlet fixture n Vacuum breaker is exposed n Product No. 32L657CW Fixtures 92 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products n All copper pipe is Type ”L” copper. Copper pipe joints are either soldered with 95/5 solder or are mechanically attached with compression fittings. n Front-loaded service fixtures are not available in standard pre-piped configurations. n Verify compliance with all state and local codes prior to ordering. n Products on this page cannot be shipped loose. Standard Configurations The following four pre-piping configurations are available with standard list pricing and standard lead-times. Piped to Turn-Down Elbow Piped to Turn-Up Elbow 6.00” Piped to Top of Fume Hood Piped to Bottom of Fume Hood 6.00” Vacuum Breaker Configurations Pre-piped cold water fixtures are available with vacuum breakers in two configurations. State and local codes will dictate the version that should be used in your location. Top Vacuum Breaker Top Front Vacuum Breaker Product Numbers – Standard Pre-piped Fixture Configurations Product No. To Up Elbow 32L80200 32L80300 32L80500 32L81400 32L81700 32L81800 32L82600 32L83000 32L84600 32L85000 32L91500 32L91600 30L80000 30L80100 30L80200 30L80300 30L82100 To Down Elbow 32L80000 32L80100 32L80400 32L81300 32L81900 32L82000 32L82500 32L82900 32L91900 32L92000 32L84500 32L84900 30L80500 30L80600 30L80700 30L80800 30L82000 Piped Up 32L80800 32L80900 32L81100 32L81600 32L82800 32L83200 32L842CW 32L844CW 32L84800 32L85200 30L81000 30L81100 30L81200 30L81300 30L82200 Piped Down 32L80600 32L80700 32L81000 32L81500 32L82700 32L83100 32L841CW 32L843CW 32L84700 32L85100 30L81500 30L81600 30L81700 30L81800 30L82300 Fixture Type Pipe Size/Material CW Front HW Front Steam Front CW Rear CW Front w/ Top VB CW Rear w/ Top VB H & CW Front H & CW Rear H & CW Rear w/ Top VB H & CW Front w/ Top VB CW Rear w/ Top Front VB CW Front w/ Top Front VB Air Front Vacuum Front Nitrogen Front Oxygen Front Gas Front 3/8” Copper 3/8” Copper 3/8” Black Iron 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Black Iron w/ Coupling CW Front HW Front Steam Front CW Rear CW Front w/ Top VB CW Rear w/ Top VB H & CW Front H & CW Rear CW Rear w/ Top Front VB CW Front w/ Top Front VB H & CW Rear w/ Top VB H & CW Front w/ Top VB Air Front Vacuum Front Nitrogen Front Oxygen Front Gas Front 3/8” Copper 3/8” Copper 3/8” Black Iron 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Black Iron w/ Coupling CW Front HW Front Steam Front CW Rear H & CW Front H & CW Rear CW Rear w/ Top VB CW Front w/ Top VB H & CW Rear w/ Top VB H & CW Front w/ Top VB Air Front Vacuum Front Nitrogen Front Oxygen Front Gas Front 3/8” Copper 3/8” Copper 3/8” Black Iron 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Black Iron w/ Coupling CW Front HW Front Steam Front CW Rear H & CW Front H & CW Rear CW Rear w/ Top VB CW Front w/ Top VB H & CW Rear w/ Top VB H & CW Front w/ Top VB Air Front Vacuum Front Nitrogen Front Oxygen Front Gas Front 3/8” Copper 3/8” Copper 3/8” Black Iron 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Copper 3/8” Black Iron w/ Coupling Fixtures Product information: n For fume hood that are pre-piped for a downward connection, pipes are pivoted upward for shipment and installation on top of the fume hood’s work-surface. Prior to making final hookups, disconnect the pipes at the valves, point them down and reinstall. n All piping configurations listed comply with the following national plumbing codes: SPC – Standard Plumbing Code NPC – National Plumbing Code UPC – Uniform Plumbing Code NSPC – National Standard Plumbing Code. 93 Thermo Scientific Hamilton Air Flow Products Common features: n Fixture has forged brass valve body and outlet. n Straight front panel mounting only. n Valve is chrome plated. n Valve seat can be replaced from the front of fixture. n Valve handle is chrome-plated with nylon color-coded index button. n Outlets in fume hood have acid- and solvent-resistant color-coded finish to match index button, with black washer. n Removable serrated tip. n Pressure varies with fixture: Water 80 PSI Needle Valve 125 PSI Steam Valve 20 PSI n Index buttons are included with fixtures. Installation requirements: n Requires 1” (25 mm) mounting hole at interior end panels. n Requires 1-1/4” (32 mm) mounting hole at front posts. Front-loaded Water Faucets n Single-service valve Turret base with serrated hose end n Without vacuum breaker n Tin-lined model for distilled water n For use with cupsink at front or back n Product No. Service 32L645CW 32L645HW 32L64800 Cold Water Hot Water Distilled Water n Single-service valve with vacuum breaker n Turret base with serrated hose end n For use with cupsink at front or back n General mixing faucet, hot and cold water with vacuum breaker n Turret base with serrated hose end n For use with cupsink at front or back Product No. 32L64900 n Needle valve service for gases, air and vacuum n Flat mounting flange with angle serrated hose end Product No. Service Product No. Service 32L647CW 32L647HW Cold Water Hot Water 30L589GW 30L589AW 30L589VW 30L589NW 30L589OW Gas Air Vacuum Nitrogen Oxygen n General mixing faucet, hot and cold water n Turret base with serrated hose end n Without vacuum breaker n For use with cupsink at front or back Fixtures Product No. 32L64600 94 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Common features of front loaded colortec valves Fixture has brass valve body with white hybrid epoxy/polyester blend finish. n Color-coded (per media) plastic hooded handle and plastic index button. n Color-coded (per media) removable serrated hose end with internal shank. n Shank washer finished in black powdercoat. n Installation requirements n Shipped loose – for field installation only. n Requires 1” (25 mm) mounting hole at interior end panels. n Requires 1-1/4” (32 mm) mounting hole at front posts. Atmospheric Vacuum Breaker Front-loaded ColorTec Water Faucets n 3/8” (10 mm) IPS laboratory vacuum breaker n Panel-mounted n 3/8” (10 mm) IPS mounting shank with locknut and washer n Panel-mount turret base with 6” (152 mm) rigid gooseneck n For straight front fume hood n Serrated hose end and internal shank n For use with cupsink installed front or back Product No. Service 28L152CW 28L152HW* Cold water Hot water * Available on extended lead time. Product No. 28L02700* * Available on extended lead time. n Brass vacuum breaker assembly with white powdercoat finish n For use with concealed piping n Union connection n 3/8” IPS female inlet and outlet Product No. 32L27700 n Single-service water valve n For straight front fume hood n Serrated hose end and internal shank Product No. Service 28L151CW 28L151HW Cold water Hot water Fixture replacement parts are available in the Thermo Scientific Hamilton Fixtures and Accessories catalog. Front-loaded Service Valves n Single-service valve For straight front fume hood n Panel-mount 30° angle outlet fitting n Serrated hose end and internal shank n Oxygen and nitrogen valves are cleaned for pure gas service Product No. Service 27L161A0 27L161G0 27L161V0 27L16200 27L16300 Air Gas Vacuum Oxygen Nitrogen Fixtures n 95 Thermo Scientific Hamilton Air Flow Products Air Flow Alarm Monitor – AFA500 Air Flow Alarm Monitor – AFA1000 n n Monitors Continuously monitors flow based on internal fume hood pressure and has field adjustable set points that will activate the alarm signal n Operations manual is provided n Features: – Low air alarm relay output – Simplified push-button calibration – Relay input for night setback to mute audible alarm n Specifications: Specifications: Alarm range: 30-400 fpm (.15-2.0 m/s) Field setup: One-point velocity calibration Accuracy: +or – 10% Airflow sensor: On-board Low air alarm delay: fixed five seconds Relay: Output – 1 Input – 2, night setback & sash high Analog Output: Not available Sash High Indication: Yes, using a micro or proximity switch input. With repeat alarm feature factory set to 5 minutes (Can be adjusted via laptop up to 30 minutes) Night Setback: Yes, using a relay input External Alarm Indication: Not available Power: Input 120VAC, 60Hz Output 15VDC, 500ma Display, visual: Red LED – Alarm Green LED – Normal Alarm Indication: Red LED and audible Horn Silence: Yes, temporary Mounting: Semi-flush Operating Temperature: 55-86oF, 13-30oC Dimensions: 5.2”H x 3-1/2”W x 2”D (132 x 81 x 51 mm) Agency Listing: UL and CE Product No. n Continuously monitors flow based on internal fume hood pressure and has field adjustable set points that will activate the alarm signal Operations manual is provided Features: – Digital display of face velocity – LED alarm indicators – Push-button calibration and configuration – One programmable output relays – Three configurable inputs – Com ports for local or network connection Display/Alarm range: 0-999 fpm (0-5.0 m/s) Field Setup: Two-point velocity calibration, with on-screen instructions Accuracy: Sensor/display resolution 1 fpm. Face velocity +or – 10% Alarm Delays: 0-60 sec. Relay: Output – 1, Input – 3 Analog Output: Not available Sash High Indication: Yes, with separate plug-in connection Night Setback: Yes External Alarm Indication: Yes Power: Input 120VAC, 60Hz, Output 15VDC, 500ma Units: English and metric, user selective Display, visual: Analog bar graph or fault timeline Red LED – Alarm Yellow LED – Caution Green LED – Normal Digital display of velocity reading can be turned off Alarm Indication: Red LED and audible Horn Silence: Yes, temporary Airflow sensor: Remote Low air alarm delay: fixed five seconds Mounting: Semi-flush o o Operating Temperature: 55-86 F, 13-30 C Dimensions: 5.2”H x 3.2”W x 2”D (132 x 81 x 51 mm) Agency Listing: UL and CE Fume Hood Use Factory Installed (Pre-wired) 54LAFA0500S4 SafeAire, 3 and 4-foot 54LAFA0500S5 SafeAire, 5-foot 54LAFA0500S6 SafeAire, 6-foot 54LAFA0500S8 SafeAire, 8-foot 54LAFA0500C4 Concept and Pioneer, 4-foot 54LAFA0500C5 Concept and Pioneer, 5-foot 54LAFA0500C6 Concept and Pioneer, 6-foot 54LAFA0500C7 Concept and Pioneer, 7-foot 54LAFA0500C8 Concept and Pioneer, 8-foot 54LAFA0500D0 Demonstration Field Installed (Cartoned) 54LAFA0500S1 10’ post-less sash fume hood 54LAFA0500S3 12’ post-less sash fume hood 54LAFA0500SC SafeAire, Concept and Pioneer 54LAFA0500HC Demonstration Product No. Fume Hood Use Factory Installed (Pre-wired) 54LAFA1000S4 SafeAire, 3 and 4-foot 54LAFA1000S5 SafeAire, 5-foot 54LAFA1000S6 SafeAire, 6-foot 54LAFA1000S8 SafeAire, 8-foot 54LAFA1000C4 Concept and Pioneer, 4-foot 54LAFA1000C5 Concept and Pioneer, 5-foot 54LAFA1000C6 Concept and Pioneer, 6-foot 54LAFA1000C7 Concept and Pioneer, 7-foot 54LAFA1000C8 Concept and Pioneer, 8-foot 54LAFA1000H0 Horizon 54LAFA1000D0 Demonstration 54LAFA0500S1 10’ postless sash fume hood 54LAFA0500S3 12’ postless sash fume hood Field Installed (Cartoned) 54LAFA1000SC SafeAire, Concept and Pioneer 54LAFA1000HC Horizon and Demonstration * Cartoned – alarm only. Attachment, electrical conduit or receptacle are not included. For use only on constant volume exhaust fume hood/systems. 96 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Epoxy Resin Stainless Steel Chemical-resistance S G Heat-resistance S G Stain-resistance G G Moisture-resistance E S Impact-resistance E S Abrasion-resistance G E Cleanability G E Sanitation P E Spill Containment G G Maintenance Cost Low Low Smoke Toxicity Low Low Disposal Impact Low Low S = Superior E = Excellent G = Good F = Fair Work Surfaces Proper selection of work surface material is critical for optimum fume hood performance. P = Poor Detailed chemical resistance test data is available upon request. 97 Thermo Scientific Hamilton Air Flow Products Common features: n Work surfaces are dished 3/8” (10 mm). n Work surfaces have a black, low-sheen finish. n Cupsink cutouts are sized for product no. 34L13200 polyolefin cupsinks. Special cutouts must be specified if alternate cupsinks are selected. n 1-1/4” (32 mm) thick. Ordering information: n Cutout only included; cupsinks and other service fixtures must be ordered separately. n 21L Series work surfaces are laid-up construction, not molded. Epoxy Resin for only SafeAire Fume Hood Product Numbers – Rear Right Cupsink Cutout Work Surface Depth 42” (1067 mm) 30” (762 mm) 34-3/4” (883 mm) 36” (914 mm) 54L – Fume Hood 60L – Fume Hood 61L – Fume Hood 62L – Fume Hood Width Epoxy Resin for only SafeAire Fume Hood Work Surfaces 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 20L19400 20L19500 20L19600 20L19700 20L19800 21L56500 21L56600 21L56700 21L56800 21L56900 — 21L58800 21L58900 21L59000 21L59100 — 21L60900 21L61000 21L61100 21L61200 Product Numbers – No Cupsink Cutouts Work Surface Depth 30” (762 mm) 34-3/4”” (883 mm) 36” (914 mm) 42” (1067 mm) 54L – Fume Hood 60L – Fume Hood 61L – Fume Hood 62L – Fume Hood Width 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 20L17900 20L18000 20L18100 20L18200 20L18300 21L55000 21L55100 21L55200 21L55300 21L55400 — 21L57600 21L57700 21L57800 21L57900 — 21L59700 21L59800 21L59900 21L60000 Product Numbers – Rear Left Cupsink Cutout Work Surface Depth 30” (762 mm) 34-3/4” (883 mm) 36” (914 mm) 42” (1067 mm) 54L – Fume Hood 60L – Fume Hood 61L – Fume Hood 62L – Fume Hood Width 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 20L18900 20L19000 20L19100 20L19200 20L19300 21L57000 21L57100 21L57200 21L57300 21L57400 — 21L59200 21L59300 21L59400 21L59500 — 21L61300 21L61400 21L61500 21L61600 Product Numbers – Front Right Cupsink Cutout Width 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 96” Wide Work Surface Depth 30” (762 mm) 34.75” (883 mm) 36” (914 mm) 42” (1067 mm) 54L – Fume Hood 60L – Fume Hood 61L – Fume Hood 62L – Fume Hood 20L18400 20L18500 20L18600 20L18700 20L18800 21L55500 21L55600 21L55700 21L55800 21L55900 — 21L58000 21L58100 21L58200 21L58300 — 21L60100 21L60200 21L60300 21L60400 120”/144” Wide Product Numbers – Front Right and Left Cupsink Cutout Work Surface Depth 30” (762 mm) 34.75” (883 mm) 36” (914 mm) 42” (1067 mm) 54L – Fume Hood 60L – Fume Hood 61L – Fume Hood 62L – Fume Hood Width 96” (2438 mm) 120” (3048 mm) 144” (3658 mm) 20L17500 20L26500 20L26600 21L57500 — — 21L59600 — — 21L61700 — — Product Numbers – Front Left Cupsink Cutout Width 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 98 Work Surface Depth 30” (762 mm) 34-3/4” (883 mm) 36” (914 mm) 42” (1067 mm) 54L – Fume Hood 60L – Fume Hood 61L – Fume Hood 62L – Fume Hood 20L17100 20L17200 20L17300 20L17400 20L17800 21L56000 21L56100 21L56200 21L56300 21L56400 — 21L58400 21L58500 21L58600 21L58700 — 21L60500 21L60600 21L60700 21L60800 Product Numbers – Rear Right and Left Cupsink Cutout Width 120” (3048 mm) 144” (3658 mm) Work Surface Depth 30” (762 mm) 34-3/4” (883 mm) 36” (914 mm) 42” (1067 mm) 54L – Fume Hood 60L – Fume Hood 61L – Fume Hood 62L – Fume Hood 20L26700 20L26800 — — — — — — www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Common features: n Black epoxy resin work surface. n Cupsink cutouts sized for product number 34L13200 polyolefin cupsinks. Special cutouts must be specified if alternate cupsinks are selected. n 1-1/4” (32 mm) thick. Ordering information: n Cupsinks and other service fixtures must be ordered separately. Epoxy Resin for SafeAire II and Concept Fume Hood Product Numbers – No Cupsink Cutouts 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 21L3626000 21L4826000 21L6026000 21L7226000 21L8426000 21L9626000 Work Surface Depth 30-7/8” (784 mm) 32-1/8” (815 mm) 60L – Fume Hood 61L – Fume Hood 21L3631000 21L4831000 21L6031000 21L7231000 — 21L9631000 — 21L4832000 21L6032000 21L7232000 21L8432000 21L9632000 38-1/8” (968 mm) 62L – Fume Hood — 21L4838000 21L6038000 21L7238000 21L8438000 21L9638000 Work Surfaces Width 26-1/8 (663 mm) 54L – Fume Hood Product Numbers – Left Front Cupsink Cutout Width 26-1/8” (663 mm) 54L – Fume Hood 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 21L36261LF 21L48261LF 21L60261LF 21L72261LF 21L84261LF 21L96261LF Work Surface Depth 30-7/8” (784 mm) 32-1/8” (815 mm) 60L – Fume Hood 61L – Fume Hood 21L36311LF 21L48311LF 21L60311LF 21L72311LF — 21L96311LF — 21L48321LF 21L60321LF 21L72321LF 21L84321LF 21L96321LF 38-1/8” (968 mm) 62L – Fume Hood — 21L48381LF 21L60381LF 21L72381LF 21L84381LF 21L96381LF Product Numbers – Left Rear Cupsink Cutout Width 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 26-1/8” (663 mm) 54L – Fume Hood* 21L36261LR 21L48261LR 21L60261LR 21L72261LR 21L84261LR 21L96261LR Work Surface Depth 30-7/8” (784 mm) 32-1/8” (815 mm) 60L – Fume Hood 61L – Fume Hood 21L36311LR 21L48311LR 21L60311LR 21L72311LR — 21L96311LR — 21L48321LR 21L60321LR 21L72321LR 21L84321LR 21L96321LR 38-1/8” (968 mm) 62L – Fume Hood — 21L48381LR 21L60381LR 21L72381LR 21L84381LR 21L96381LR *Rear mounted cupsink requires use of a sink base cabinet. Product Numbers – Right Front Cupsink Cutout Width 26-1/8” (663 mm) 54L – Fume Hood 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 21L36261RF 21L48261RF 21L60261RF 21L72261RF 21L84261RF 21L96261RF Work Surface Depth 30-7/8” (784 mm) 32-1/8” (815 mm) 60L – Fume Hood 61L – Fume Hood 21L36311RF 21L48311RF 21L60311RF 21L72311RF — 21L96311RF — 21L48321RF 21L60321RF 21L72321RF 21L84321RF 21L96321RF 38-1/8” (968 mm) 62L – Fume Hood — 21L48381RF 21L60381RF 21L72381RF 21L84381RF 21L96381RF 99 Thermo Scientific Hamilton Air Flow Products Common features: n Black epoxy resin work surface. n Cupsink cutouts sized for product number 34L13200 polyolefin cupsinks. Special cutouts must be specified if alternate cupsinks are selected. n 1-1/4” (32 mm) thick. Ordering information: Cupsinks and other service fixtures must be ordered separately. n Epoxy Resin for SafeAire II and Concept (continued) Product Numbers – Right Rear Cupsink Cutout Width Work Surfaces 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 26-1/8” (663 mm) 54L – Fume Hood* 21L36261RR 21L48261RR 21L60261RR 21L72261RR 21L84261RR 21L96261RR Work Surface Depth 30-7/8” (784 mm) 32-1/8” (815 mm) 60L – Fume Hood 61L – Fume Hood 21L36311RR 21L48311RR 21L60311RR 21L72311RR — 21L96311RR — 21L48321RR 21L60321RR 21L72321RR 21L84321RR 21L96321RR 38-1/8” (968 mm) 62L – Fume Hood — 21L48381RR 21L60381RR 21L72381RR 21L84381RR 21L96381RR *Rear mounted cupsink requires use of a sink base cabinet. Product Numbers – Two Front Cupsink Cutouts Width 26-1/8” (663 mm) 54L – Fume Hood 96” (2438 mm) 21L96262BF Work Surface Depth 30-7/8” (784 mm) 32-1/8” (815 mm) 60L – Fume Hood 61L – Fume Hood 21L96312BF 21L96322BF 38-1/8” (968 mm) 62L – Fume Hood 21L96382BF Epoxy Resin for Pioneer Product No. Fume Hood Width 21L4830_ _ 21L6030_ _ 21L7230_ _ 21L8430_ _ 21L9630_ _ 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) Add the following suffix letters to product numbers at left for cupsink cutout requirements: 000 = No cupsink cutouts 1LF = Left Front 1RF = Right Front 2BF = Both Front Sides (96” width only) 1LR = Left Rear 1RR = Right Rear 100 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Common features: n Stainless steel work surfaces are No. 304 stainless steel with smooth satin finish. n 1-1/4” (32 mm) thick. Ordering information: Integral cupsinks included, other service fixtures must be ordered separately. n Special cutouts must be specified if alternate cupsinks are selected. n Common features: n Work surface for use with Horizon fume hood assemblies. n Cupsink cutouts sized for product number 34L13200 polyolefin cupsinks. Special cutouts must be specified if alternate cupsinks are selected. n 1-1/4” (32 mm) thick. Ordering information: Cupsinks and other service fixtures must be ordered separately. n Horizon fume hood assemblies include a standard black epoxy resin work surface (see page 6871). n Stainless Steel for only SafeAire Fume Hood n Molded Black Resin for only Horizon Superstructures Front left cupsink 30” deep n Product No. 20L30500 20L30600 20L30700 20L30800 n n Width 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 20L30900 20L258BB 20L259BB 20L260BB n Front left and right cupsink 30” deep Product No. Two cupsinks Product No. Left cupsink Product No. 20L258BL 20L259BL 20L260BL Width 96” (2438 mm) Width 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) n Width 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) Right cupsink Product No. 20L258BR 20L259BR 20L260BR Width 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) Stainless Steel for only SafeAire II Fume Hood n n Front left cupsink n 26-1/4” deep Product No. 21L36261LFSS 21L48261LFSS 21L60261LFSS 21L72261LFSS Width 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) n Front right and left cupsink n 26-1/4” deep 21L96261LFSS Width 20L258BN 20L259BN 20L260BN 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) Molded White Resin for only Horizon Superstructure n Product No. No cupsinks Product No. Width Two cupsinks Product No. Width 20L258WB 20L259WB 20L260WB 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) n n Left cupsink Product No. Width 20L258WL 20L259WL 20L260WL 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) Right cupsink Product No. Width 20L258WR 20L259WR 20L260WR 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) n No cupsinks Product No. Width 20L258WN 20L259WN 20L260WN 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 101 Work Surfaces n Thermo Scientific Hamilton Air Flow Products n For use with: n Work surfaces with cupsink cutouts. Ordering information: Adapters to connect cupsink to plumbing must be ordered separately. Coordinate selection of plumbing fixtures, sink outlet material, trap material and building acid waste system. Glass Oval Cupsinks n 4” (102 mm) x 7” (178 mm) oval cupsink n Outlet I.D. – 1-1/2” (38 mm) n Overall height – 11” (279 mm) n Product No. 34L36100 Polyolefin Oval Cupsinks n 7-1/2” (191 mm) x 4-1/2” (114 mm) oval cupsink, 3” x 6” I.D. n IPS outlet – 1-1/2” (38 mm) n Overall height – 8-3/16” (208 mm) Stainless Steel Oval Cupsinks n Product No. 34L13200 6” (154 mm) Oval cupsink with 1-1/2” (38 mm) tailpiece n Overall diameter – 7-5/8” (194 mm) x 4-19/32” (117 mm) n Outlet – 1-1/2” (38 mm) n Overall height – 11-3/4” (298 mm) n Inside diameter – 3-23/32” (94 mm) x 6- 3/4” (172 mm) 5-11/16” (145 mm) Product No. n 7” (178 mm) x 3-7/8” (99 mm) oval panel-mounted cupsink with strainer n Outlet – 1-1/2” (38 mm) n Overall height – 6-13/16” (173 mm) Cupsinks and Tops Product No. 34L19000 34L19400 4-3/4” (121 mm) 34L19100 2x6 I.D. Cupsink Only Cupsink with Elbow Polyolefin Tailpiece n Product No. 12-5/8” (321 mm) 4-7/8” (113 mm) 18-3/4” (476 mm) 1-1/2” (38 mm) Tailpiece assembly 34L24500 n Shallow cupsink for restricted spaces, ideal for a fume hood installed above an acid or flammable storage cabinet n Provides for front-mounted location 6-3/8” above acid/flammable cabinet with (162 mm) flush front n 6” (152 mm) x 3” (76 mm) inside dimension n Outlet – 1-1/2” (38 mm) Product No. 34L13700 Shallow Cupsink with Elbow Adapter Couplings n Adapts 2” (51 mm) expanded inlet beaded-end trap to 1-1/2” (38 mm) plain-end cupsink tailpiece n Stainless steel outer band with rubber adapter and adapter seal Product No. 34L26900 34L27000 102 Tailpiece Outside Diameter 1-1/2” (38 mm) 1-3/4” (44 mm) www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Glass Swivel ”P” Traps n ”P” swivel trap Outlet I.D. – 1-1/2” (38 mm) n Inlet I.D. – 2” (51 mm) n Overall height – 8-3/4” (222 mm) n 11” (279 mm) Product No. 34L25700 1-5/8” (41 mm) 5” (127 mm) Polyolefin ”P” Traps 6-1/4” (159 mm) 5-3/16” (132 mm) 34L22400 1-1/2” (38 mm) 2” (51 mm) 2-1/2” (64 mm) - 10-1/2” (267 mm) 3-5/8” (92 mm)– 6” (152 mm) 2-1/2” (64 mm) Inlet/Outlet 34L22400 34L22500 Cupsinks and Tops 4-7/8” (124 mm) Product No. 5” (127 mm) 3-1/4” (83 mm) 34L22500 103 Thermo Scientific Hamilton Air Flow Products Base cabinets are required to support standard and high-line fume hood. Select from wood steel or plastic laminate base cabinets, or choose an acid storage or flammable liquid storage cabinet. Base cabinet assembly with 48” wide bench high-line fume hood Thermo Scientific Hamilton laboratory cabinets are available in steel, wood or plastic laminate. Examples of inset steel and lipped overlay wood base cabinets are shown for reference. Please refer to the appropriate Thermo Scientific Hamilton product specification catalog for complete cabinet offerings. Two 12” wide base-cabinets with 48” wide bench fume hood Base Cabinets Two 48” wide base cabinet assemblies with 96” wide bench fume hood 104 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products 21-5/8” (549 mm) Typical End View Steel Base Cabinets n Flush front panel above cupboard Product No. 121S5320 121S6320 121S7320 121S8320 Steel Polyethylene Lined Acid Storage Cabinets Width n 30” (762 mm) 36” (914 mm) 42” (1067 mm) 48” (1219 mm) n n For use below cupsink Flush front panel above cupboard n Use two or more of these base cabinets to support fume hood superstructure n Product No. For use with: n Fume hood superstructures. Common features: n For storage of flammable liquids. 35-1/4” n (895 mm) Two 2” (51 mm) pipe threaded vent outlets with flame arrestors on back of cabinet. n Rear and top access panel. n Label included. n Standard with locks. n Factory Mutual approved and UL listed. 21-5/8” (549 mm) n In full compliance with NFPA standards and OSHA regulations. Typical End View n Do not locate acid/flammable liquid storage cabinets under cupsinks. n Cannot be modified. Standing-height cabinet Flush panel above single left- or right-hinged door n Chemical resistant 3/16” (5 mm) thick molded Polyethylene lining with coved corners and 1” lip at front cabinet opening n Doors are lined with 1/8” (3 mm) thick polyethylene n Two vent holes in cabinet back n Removable back panel n One half-depth shelf and polyethylene spill tray Width Right-hinged (shown) 122S0320 12” (305 mm) Left-hinged 123S0320 12” (305 mm) Steel Acid Storage Cabinets Product No. Width Right-hinged (shown) 950S4190 950S4200 Left-hinged 950S2090 950S2100 18” (457 mm) 24” (610 mm) 18” (457 mm) 24” (610 mm) n n For storage of corrosive materials Flush front panel above cupboard n Chemical-resistant cement-based board lining and shelf surface n Vent access at rear n No not use under front mounted cupsinks n Product No. 144S5320 144S6320 144S7320 144S8320 Width Flush front top panel Chemical resistant 3/16” (5 mm) thick molded Polyethylene lining with coved corners and 1” lip at front cabinet opening n Doors are lined with 1/8” (3 mm) thick polyethylene n Two vent holes in cabinet back n Removable back panel n One half-depth shelf and polyethylene spill tray n 30” (762 mm) 36” (914 mm) 42” (1067 mm) 48” (1219 mm) Product No. 950S2280 950S2380 950S2400 Width 30” (762 mm) 36” (914 mm) 48” (1219 mm) n For standard depth fume hood Optional vent assembly for venting acid storage cabinets n Constructed of polyolefin n Product No. 90L06000 90L06300 For 31-1/4” deep fume hood For extended depth fume hood n Polyolefin vent pipes For venting polyethylene lined acid storage cabinets shown above n For 31-1/4” deep fume hood only n Product No. 90L07800 90L07900 Cabinet Type Full-height doors Flush panel 105 Base Cabinets 35-1/4” (895 mm) For use with: n Fume hood superstructures. Common features: n Solid hinged doors. n Shelf adjustable in 1/2” (13 mm) increments. n Standard without locks. To specify locks, change the last digit of the product number from ”0” to ”L.” n For acid storage units, use product number 34L13700 (shallow frontmounted cupsink) when required. Thermo Scientific Hamilton Air Flow Products Common features: n Available with finished or unfinished ends. n Shelf adjustable in 1-1/4” (32 mm) increments. 35” (889 mm) n Optional leveling glides provide for exact alignment of adjacent work surfaces. For use with: n Fume hood superstructures. 35-1/4” (895 mm) 21-5/8” (549 mm) Typical End View Common features: n For storage of flammable liquids. n Two 2” (51 mm) pipe threaded vent outlets with flame arrestors on back of cabinet. n Rear and top access panel. n Label included. n Standard with locks. n Factory Mutual approved and UL listed. n In full compliance with NFPA standards and OSHA regulations. n Do not locate acid/flammable liquid storage cabinets without upper flush panel under cupsinks. n Cannot be modified. Ordering information: Specify end and lock selection with suffix as follows: n 21-1/2” (546 mm) Typical End View With Finished End Right End Finished Left End Finished Both Ends Finished Both Ends Unfinished Locks Without Locks K T D P R L B U Wood Base Cabinets for Horizon Fume Hood Steel Flammable Liquid Storage Cabinets n n With flush panel n Single hinged door n Shelf adjustable in 1” (25 mm) increments. n Includes lock n Two vent outlets at rear of cabinet Inset panel above door This cabinet is not available with lock n Suffix C: With electric, fixtures holes plugged Suffix F: With electric, air, gas, vac., and CW mounted Suffix R: Electric coutout holes plugged for fixtures n Product No. Product No. Capacity Door Type Self-closing door 950S7761 12 gal. (45.4 l) 950S7771 12 gal. (45.4 l) Manual-closing door 950S7641 12 gal. (45.4 l) 950S7651 12 gal. (45.4 l) Width Right-hinged Left-hinged 24” (610 mm) 24” (610 mm) Right-hinged Left-hinged 24” (610 mm) 24” (610 mm) Width Right-hinged door (shown), finished right end, unfinished left end 204C032C 12” (305 mm) 204C032F 12” (305 mm) 204C032R 12” (305 mm) Left-hinged, finished left end, unfinished right end 205C032C 12” (305 mm) 205C032F 12” (305 mm) 205C032R 12” (305 mm) n With flush panel Double hinged doors n Shelf adjustable in 1” (25 mm) increments. n Includes lock n Two vent outlets at rear of cabinet n Base Cabinets Product No. Capacity Self-closing doors 950S7781 15 gal. (56.8 l) 950S7791 18 gal. (68.1 l) 950S7801 24 gal. (90.8 l) 950S7811 27 gal. (102.2 l) Manual-closing doors 950S7661 15 gal. (56.8 l) 950S7671 18 gal. (68.1 l) 950S7681 24 gal. (90.8 l) 950S7691 27 gal. (102.2 l) Width 30” (762 mm) 36” (914 mm) 42” (1067 mm) 48” (1219 mm) 30” (762 mm) 36” (914 mm) 42” (1067 mm) 48” (1219 mm) n Optional vent assembly for venting flammable liquid storage cabinets n Made of polyolefin n Inset panel above door This cabinet is not available with lock n Suffix C: With electric, plugs for fixtures Suffix F: With electric, fixture handles for air, gas, vac., and CW Suffix R: No electric, plugs for fixtures n Product No. Width Right-hinged door (shown), finished right end, unfinished left end 204C232C 18” (457 mm) 204C232F 18” (457 mm) 204C232R 18” (457 mm) Left-hinged, finished left end, unfinished right end 205C232C 18” (457 mm) 205C232F 18” (457 mm) 205C232R 18” (457 mm) 204C-series product number with electric includes a switch 205C-series product number with electric does not include a switch Product No. 90L19000 106 For 31-1/4” deep fume hood www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Wood Base Cabinets Wood Solvent Storage Cabinets n Inset panel above cupboard Product No. Right-hinged (shown) 121C032 Left-hinged 123C032 Inset Panel Shown n n Top panel inset with cabinet ends For storage of flammable liquids n UL listed and FM approved n 12 gallon (56 l) capacity n Width 12” (305 mm) Product No. 12” (305 mm) Right-hinged 950C764D Left-hinged (shown) 950C765D Inset or recessed panel above cupboard Product No. 121C532 121C632 121C732 121C832 Recessed panel 120C532 120C632 120C732 120C832 Width Width 24” (610 mm) 24” (610 mm) n Top panel inset with cabinet ends For storage of flammable liquids n UL listed and FM approved 30” (762 mm) 36” (914 mm) 42” (1067 mm) 48” (1219 mm) n Product No. 950C766D 950C767D 950C768D 950C769D 30” (762 mm) 36” (914 mm) 42” (1067 mm) 48” (1219 mm) Capacity 15 gal. (57L) 18 gal. (68L) 24 gal. (91L) 27 gal. (102L) Width 30” (762 mm) 36” (914 mm) 42” (1066 mm) 48” (1219 mm) Wood Acid Storage Cabinets n Polyolefin vent pipes For venting solvent storage base cabinets through fume hood n For 31-1/4” deep fume hood only n Inset panel (flush with ends) above right- or left-hinged door n Chemical resistant 1/4” (6 mm) cement-based board lining n Vent access at rear Product No. n Width Product No. Cabinet Type 90L18900 For cabinets with Inset front top panels Right-hinged (shown) 122C432 24” (610 mm) Left-hinged 123C432 24” (610 mm) Inset panel (flush with cabinet ends) above double hinged doors n Full-height hinged double doors n Chemical resistant 1/4” (6 mm) cement-based board lining n Vent access at rear Fume Hood Cabinet Accessories n n Filler end panel For enclosing service space at rear of base cabinet Product No. Product No. 144C532 144C632 144C732 144C832 Width For Steel Base Cabinets 30” (762 mm) 36” (914 mm) 42” (1067 mm) 48” (1219 mm) For steel cabinets 611S7320 For wood cabinets 611C7320 Width 7-3/8” (187 mm) 7” (178 mm) n Polyethylene vent pipe For venting cement-based board lined acid storage cabinets n On all cabinets, vent hole is 10” from top and from right side n Product No. 90L06600 For Wood Base Cabinets For Cabinet Type Inset panel above door Dimension are nominal and illustrations and specifications are based on the latest product information available at the time of publication. The right is reserved to make changes at any time without notice. 107 Base Cabinets n Thermo Scientific Hamilton Air Flow Products n Add 1/2” (13 mm) to depth for lipped 32-1/4” (819 mm) n Shelves are adjustable in design; add 7/8” (22 mm) to depth for flush and radius design. n Available with finished or unfinished outside ends n For extended depth ends, change 7th digit in product number to a 3 n Shelves are adjustable in 1-1/4” (32 mm) increments 1/2” (13mm) increments. n Units are standard without 32” (813 mm) 21-1/2” (546 mm) 31” (787 mm) Extended Depth 21-5/8” (549 mm) Typical End View Typical End View locks. Replace the ”0” with an ”L” in the eighth position of product number to specify a unit with locks for drawers and doors. n Available with service access in back as noted. ADA Base Cabinets – Steel ADA Base Cabinets – Wood n Flush panel above cupboard with right n Inset panel above right- or left- or left-hinged door hinged swinging door n Removable back panel Product No. Right-hinged (shown) 121C072 Left-hinged 123C072 Width Product No. 12” (305 mm) 12” (305 mm) Width Right-hinged 122S0720 122S4720 Left-hinged 123S0720 123S4720 12” (305 mm) 24” (610 mm) 12” (305 mm) 24” (610 mm) n Inset or recessed panel above hinged Inset Panel Shown double doors Product No. Width ADA Base Cabinets Inset panel (flush with cabinet ends) 121C572 30” (762 mm) 121C672 36” (914 mm) 121C772 42” (1067 mm) 121C872 48” (1219 mm) Recessed panel 120C572 30” (762 mm) 120C672 36” (914 mm) 120C772 42” (1067 mm) 120C872 48” (1219 mm) n Inset panel (flush with cabinet ends) Inset Panel above right- or left-hinged swinging door Product No. Right hinged (shown) 012C272 Left hinged 013C272 108 Width 18” (457 mm) 18” (457 mm) n Flush panel above cupboard with double swinging doors n Removable back panel Product No. Width 121S5720 121S6720 121S7720 121S8720 30” (762 mm) 36” (914 mm) 42” (1067 mm) 48” (1219 mm) n Flush top panel above left or right- hinged door. n Back cut out for large sinks. Product No. Right hinged 112C2720 Left hinged 113C2720 Width 18” (457 mm) 18” (457 mm) www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Shelf Protector Trays Shelf Protector Trays n n n n White polyolefin tray Fits into cupboard bottom or on full-depth shelf n 1” (25 mm) lip on four sides to contain spills Product No. Tray Size White polyolefin tray Fits into cupboard bottom or on full-depth shelf n 2” (129 mm) lip on four sides to contain spills Fits Cabinet Width For Steel Base Cabinets 90L23191* 23” x 19” (584 x 483 mm) 90L29191* 29” x 19” (737 x 483 mm) 90L35191* 35” x 19” (890 x 483 mm) 90L41191 41” x 19” (1041 x 483 mm) 90L47191* 47” x 19” (1194 x 483 mm) 90L57191* 57” x 19” (1148 x 483 mm) 24” (610 mm) 30” (762 mm) 36” (914 mm) 42” (1067 mm) 48” (1219 mm) 58” (1473 mm) Product No. Tray Size Fits Cabinet Width For Steel Base Cabinets 90L23192* 23” x 19” (584 x 483 mm) 90L29192* 29” x 19” (737 x 483 mm) 90L35192* 35” x 19” (890 x 483 mm) 90L41192* 41” x 19” (1041 x 483 mm) 90L47192* 47” x 19” (1194 x 483 mm) 90L57192 57” x 19” (1148 x 483 mm) 24” (610 mm) 30” (762 mm) 36” (914 mm) 42” (1067 mm) 48” (1219 mm) 58” (1473 mm) For Steel & Wood Acid Storage Cabinets and Wood Base Cabinets 90L21191* 21” x 19” (533 x 483 mm) 24” (610 mm) 90L27191* 27” x 19” (686 x 483 mm) 30” (762 mm) 90L33191* 33” x 19” (838 x 483 mm) 36” (914 mm) 90L39191* 39” x 19” (991 x 483 mm) 42” (1067 mm) 90L45191* 45” x 19” (1143 x 483 mm) 48” (1219 mm) For Steel & Wood Acid Storage Cabinets and Wood Base Cabinets 90L21192* 21” x 19” (533 x 483 mm) 24” (610 mm) 90L27192* 27” x 19” (686 x 483 mm) 30” (762 mm) 90L33192* 33” x 19” (838 x 483 mm) 36” (914 mm) 90L39192* 39” x 19” (991 x 483 mm) 42” (1067 mm) 90L45192* 45” x 19” (1143 x 483 mm) 48” (1219 mm) For Steel & Wood Flammable Storage Base Cabinets 90L19161* 19” x 16” (483 x 406 mm) 90L25161* 25” x 16” (635 x 406 mm) 90L29161* 29” x 16” (737 x 406 mm) 90L31161* 31” x 16” (787 x 406 mm) 90L37161* 37” x 16” (940 x 406 mm) 90L43161* 43” x 16” (1092 x 406 mm) For Steel & Wood Flammable Storage Base Cabinets 90L19162* 19” x 16” (483 x 406 mm) 90L25162* 25” x 16” (635 x 406 mm) 90L29162* 29” x 16” (737 x 406 mm) 90L31162* 31” x 16” (787 x 406 mm) 90L37162* 37” x 16” (940 x 406 mm) 90L43162* 43” x 16” (1092 x 406 mm) 24” (610 mm) 30” (762 mm) 34” (864 mm) 36” (914 mm) 42” (1067 mm) 48” (1219 mm) For Other Steel Flammable Storage Cabinets 90L14131 13” x 14” (330 x 356 mm) 90L25251 25” x 25” (635 x 635 mm) 90L37141 37” x 14” (940 x 356 mm) 950S8421 950S8411 950S8401 24” (610 mm) 30” (762 mm) 34” (864 mm) 36” (914 mm) 42” (1067 mm) 48” (1219 mm) For Other Steel Flammable Storage Cabinets 90L14132 13” x 14” (330 x 356 mm) 90L25252 25” x 25” (635 x 635 mm) 90L37142 37” x 14” (940 x 356 mm) 950S8421 950S8411 950S8401 * Available on extended lead time. * Available on extended lead time. Steel Cabinets Dimensions Overall Outside Dimensions Cupboard Inside Dimensions Width Height Depth Width Base Cabinets Height 12” (305 mm) 24” (610 mm) 30” (762 mm) 36” (914 mm) 48” (1219 mm) 35-1/4” (895 mm) 35-1/4” (895 mm) 35-1/4” (895 mm) 35-1/4” (895 mm) 35-1/4” (895 mm) 21-5/8” (549 mm) 21-5/8” (549 mm) 21-5/8” (549 mm) 21-5/8” (549 mm) 21-5/8” (549 mm) 11-7/8” (302 mm) 23-7/8” (606 mm) 29-7/8” (759 mm) 35-7/8” (911 mm) 47-7/8” (1216 mm) 29-3/4” (756 mm) 29-3/4” (756 mm) 29-3/4” (756 mm) 29-3/4” (756 mm) 29-3/4” (756 mm) Acid Storage Cabinets Height Depth Depth Width 20” (508 mm) 20” (508 mm) 20” (508 mm) 20” (508 mm) 20” (508 mm) 9-1/2” (241 mm) 21-1/2” (546 mm) 27-1/2” (699 mm) 33-1/2” (699 mm) 45-1/2” (1156 mm) 22-1/8” (562 mm) 22-1/8” (562 mm) 22-1/8” (562 mm) 22-1/8” (562 mm) 22-1/8” (562 mm) 19-1/2” (495 mm) 19-1/2” (495 mm) 19-1/2” (495 mm) 19-1/2” (495 mm) 19-1/2” (495 mm) Wood Cabinets Dimensions Cupboard Inside Dimensions Width Height Depth Width Base Cabinets Height 12” (305 mm) 24” (610 mm) 30” (762 mm) 36” (914 mm) 48” (1219 mm) 34-3/4” (883 mm) 34-3/4” (883 mm) 34-3/4” (883 mm) 34-3/4” (883 mm) 34-3/4” (883 mm) 22” (559 mm) 22” (559 mm) 22” (559 mm) 22” (559 mm) 22” (559 mm) 10-1/2” (267 mm) 22-1/2” (572 mm) 28-1/2” (724 mm) 34-1/2” (876 mm) 46-1/2” (1181 mm) 20-1/8” (511 mm) 20-1/8” (511 mm) 20-1/8” (511 mm) 20-1/8” (511 mm) 20-1/8” (511 mm) Acid Storage Cabinets Height Depth Depth Width 20-7/8” (530 mm) 20-7/8” (530 mm) 20-7/8” (530 mm) 20-7/8” (530 mm) 20-7/8” (530 mm) 10” (254 mm) 22” (559 mm) 28” (711 mm) 34” (864 mm) 46” (1168 mm) 20” (508 mm) 20” (508 mm) 20” (508 mm) 20” (508 mm) 20” (508 mm) 20-3/8” (518 mm) 20-3/8” (518 mm) 20-3/8” (518 mm) 20-3/8” (518 mm) 20-3/8” (518 mm) 109 Shelf Protectors Overall Outside Dimensions Thermo Scientific Hamilton Air Flow Products For Bench and High-line Hood (continued) Enclosures Product features: n Provides finished appearance between fume hood and ceiling. n Conceals and protects fume hood ductwork, electrical conduit and vertical service supply lines. n n Finished to match superstructure. 12-1/2” (318 mm) height can be cut down in field for ceilings as low as 8 feet. For SafeAire and SafeAire II n Bench and high line only Use to enclose space between ceiling and top of fume hood superstructure n Made of steel, finished to match fume hood superstructure n Installation hardware included n Lower front panel is removable for access to light fixture n Product No. Width Height Depth 54L0361231 54L0361731 54L0362431 54L0362931 54L0363631 54L0481231 54L0481731 54L0482431 54L0482931 54L0483631 54L0601231 54L0601731 54L0602431 54L0602931 54L0603631 54L0721231 54L0721731 54L0722431 54L0722931 54L0723631 54L0961231 54L0961731 54L0962431 54L0962931 54L0963631 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 60L0361236 60L0361736 60L0362436 60L0362936 60L0363636 60L0481236 60L0481736 60L0482436 60L0482936 60L0483636 60L0601236 60L0601736 60L0602436 60L0602936 60L0603636 60L0721236 60L0721736 60L0722436 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 110 Product No. Width Height 60L0722936 60L0723636 60L0961236 60L0961736 60L0962436 60L0962936 60L0963636 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) 61L0361237 61L0361737 61L0362437 61L0362937 61L0363637 61L0481237 61L0481737 61L0482437 61L0482937 61L0483637 61L0601237 61L0601737 61L0602437 61L0602937 61L0603637 61L0721237 61L0721737 61L0722437 61L0722937 61L0723637 61L0961237 61L0961737 61L0962437 61L0962937 61L0963637 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) 62L0361243 62L0361743 62L0362443 62L0362943 62L0363643 62L0481243 62L0481743 62L0482443 62L0482943 62L0483643 62L0601243 62L0601743 62L0602443 62L0602943 62L0603643 62L0721243 62L0721743 62L0722443 62L0722943 62L0723643 62L0961243 62L0961743 62L0962443 62L0962943 62L0963643 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (182 9 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” 12-1/2” 17” 24-1/2” 29” 36-1/2” (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) (318 mm) (431 mm) (622 mm) (737 mm) (927 mm) Depth 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 36” (914 mm) 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 37-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” 43-1/4” (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (946 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) (1099 mm) Installation information: With suspended ceilings, it is suggested that the enclosure assembly extend to the bottom of the ceiling. The hung ceiling should extend over the top of the fume hood and be trimmed around the mechanical connections to ensure proper room pressure control of the HVAC system. www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products For SafeAire Auxiliary Air Fume Hood n Enclosures Bench and high line only Use to enclose space between ceiling and top of fume hood superstructure n Made of steel, finished to match fume hood superstructure n Installation hardware included n Add ”S” to end of product number to designate for fume hood with stainless steel interior n Product No. Width Height Depth Product No. Width Height Depth 54L0482434 54L0482934 54L0483634 54L0602434 54L0602934 54L0603634 54L0722434 54L0722934 54L0723634 54L0962434 54L0962934 54L0963634 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) 33-13/16” (859 mm) 33-13/16” (859 mm) 33-13/16” (859 mm) 33-13/16” (859 mm) 33-13/16” (859 mm) 33-13/16” (859 mm) 33-13/16” (859 mm) 33-13/16” (859 mm) 33-13/16” (859 mm) 33-13/16” (859 mm) 33-13/16” (859 mm) 33-13/16” (859 mm) 61L0482440 61L0482940 61L0483640 61L0602440 61L0602940 61L0603640 61L0722440 61L0722940 61L0723640 61L0962440 61L0962940 61L0963640 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) 39-13/16” (1011 mm) 39-13/16” (1011 mm) 39-13/16” (1011 mm) 39-13/16” (1011 mm) 39-13/16” (1011 mm) 39-13/16” (1011 mm) 39-13/16” (1011 mm) 39-13/16” (1011 mm) 39-13/16” (1011 mm) 39-13/16” (1011 mm) 39-13/16” (1011 mm) 39-13/16” (1011 mm) 60L0482439 60L0482939 60L0483639 60L0602439 60L0602939 60L0603639 60L0722439 60L0722939 60L0723639 60L0962439 60L0962939 60L0963639 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) 38-5/8” (980 mm) 38-5/8” (980 mm) 38-5/8” (980 mm) 38-5/8” (980 mm) 38-5/8” (980 mm) 38-5/8” (980 mm) 38-5/8” (980 mm) 38-5/8” (980 mm) 38-5/8” (980 mm) 38-5/8” (980 mm) 38-5/8” (980 mm) 38-5/8” (980 mm) 62L0482446 62L0482946 62L0483646 62L0602446 62L0602946 62L0603646 62L0722446 62L0722946 62L0723646 62L0962446 62L0962946 62L0963646 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) 45-13/16” (1164 mm) 45-13/16” (1164 mm) 45-13/16” (1164 mm) 45-13/16” (1164 mm) 45-13/16” (1164 mm) 45-13/16” (1164 mm) 45-13/16” (1164 mm) 45-13/16” (1164 mm) 45-13/16” (1164 mm) 45-13/16” (1164 mm) 45-13/16” (1164 mm) 45-13/16” (1164 mm) For SafeAire Demonstration Fume Hood n Use to enclose space between ceiling and top of fume hood superstructure. n Made of steel, finished to match fume hood superstructure. n Installation hardware included. n Add ”S” to end of product number to designate for fume hood with stainless steel interior. n Lower front panel is removable for access to light fixture. Product No. Width Height Depth 54L0601233 54L0602433 54L0603633 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 12-1/2” (318 mm) 24-1/2” (622 mm) 36-1/2” (927 mm) 32-1/2” (826 mm) 32-1/2” (826 mm) 32-1/2” (826 mm) Installation information: With suspended ceilings, it is suggested that the enclosure assembly extend to the bottom of the ceiling. The hung ceiling should extend over the top of the fume hood and be trimmed around the mechanical connections to ensure proper room pressure control of the HVAC system. 111 Thermo Scientific Hamilton Air Flow Products For SafeAire Floor-mounted Fume Hood For SafeAire Auxiliary Air Floor-mounted Fume Hood n n Enclosures Use to enclose space between ceiling and top of floor-mounted fume hood n Made of steel, finished to match fume hood superstructure n Installation hardware included n Add ”S” to end of product number to designate for fume hood with stainless steel interior n Lower front panel is removable for access to light fixture Product No. Width Height Depth 554S0482432 554S0482932 554S0483632 554S0602432 554S0602932 554S0603632 554S0722432 554S0722932 554S0723632 554S0962432 554S0962932 554S0963632 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) 32-3/8” (822 mm) 32-3/8” (822 mm) 32-3/8” (822 mm) 32-3/8” (822 mm) 32-3/8” (822 mm) 32-3/8” (822 mm) 32-3/8” (822 mm) 32-3/8” (822 mm) 32-3/8” (822 mm) 32-3/8” (822 mm) 32-3/8” (822 mm) 32-3/8” (822 mm) 551S0482438 551S0482938 551S0483638 551S0602438 551S0602938 551S0603638 551S0722438 551S0722938 551S0723638 551S0962438 551S0962938 551S0963638 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) 38-3/8” (974 mm) 38-3/8” (974 mm) 38-3/8” (974 mm) 38-3/8” (974 mm) 38-3/8” (974 mm) 38-3/8” (974 mm) 38-3/8” (974 mm) 38-3/8” (974 mm) 38-3/8” (974 mm) 38-3/8” (974 mm) 38-3/8” (974 mm) 38-3/8” (974 mm) 552S0482444 552S0482944 552S0483644 552S0602444 552S0602944 552S0603644 552S0722444 552S0722944 552S0723644 552S0962444 552S0962944 552S0963644 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) 44-3/8” (1126 mm) 44-3/8” (1126 mm) 44-3/8” (1126 mm) 44-3/8” (1126 mm) 44-3/8” (1126 mm) 44-3/8” (1126 mm) 44-3/8” (1126 mm) 44-3/8” (1126 mm) 44-3/8” (1126 mm) 44-3/8” (1126 mm) 44-3/8” (1126 mm) 44-3/8” (1126 mm) Use to enclose space between ceiling and top of floor-mounted fume hood n Made of steel, finished to match fume hood superstructure n Installation hardware included n Add ”S” to end of product number to designate for fume hood with stainless steel interior Product No. 554S0482435 554S0482935 554S0483635 554S0602435 554S0602935 554S0603635 554S0722435 554S0722935 554S0723635 554S0962435 554S0962935 554S0963635 551S0482441 551S0482941 551S0483641 551S0602441 551S0602941 551S0603641 551S0722441 551S0722941 551S0723641 551S0962441 551S0962941 551S0963641 552S0482447 552S0482947 552S0483647 552S0602447 552S0602947 552S0603647 552S0722447 552S0722947 552S0723647 552S0962447 552S0962947 552S0963647 Width 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) Height 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” 24-1/2” 29” 36-1/2” (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) (622 mm) (737 mm) (927 mm) Depth 34-15/16” (887 mm) 34-15/16” (887 mm) 34-15/16” (887 mm) 34-15/16” (887 mm) 34-15/16” (887 mm) 34-15/16” (887 mm) 34-15/16” (887 mm) 34-15/16” (887 mm) 34-15/16” (887 mm) 34-15/16” (887 mm) 34-15/16” (887 mm) 34-15/16” (887 mm) 40-15/16” (1040 mm) 40-15/16” (1040 mm) 40-15/16” (1040 mm) 40-15/16” (1040 mm) 40-15/16” (1040 mm) 40-15/16” (1040 mm) 40-15/16” (1040 mm) 40-15/16” (1040 mm) 40-15/16” (1040 mm) 40-15/16” (1040 mm) 40-15/16” (1040 mm) 40-15/16” (1040 mm) 46-15/16” (1192 mm) 46-15/16” (1192 mm) 46-15/16” (1192 mm) 46-15/16” (1192 mm) 46-15/16” (1192 mm) 46-15/16” (1192 mm) 46-15/16” (1192 mm) 46-15/16” (1192 mm) 46-15/16” (1192 mm) 46-15/16” (1192 mm) 46-15/16” (1192 mm) 46-15/16” (1192 mm) Installation information: With suspended ceilings, it is suggested that the enclosure assembly extend to the bottom of the ceiling. The hung ceiling should extend over the top of the fume hood and be trimmed around the mechanical connections to ensure proper room pressure control of the HVAC system. 112 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products For SafeAire Postless Sash Fume Hood SafeAire Finished Backs Use to enclose space between ceiling and top of fume hood superstructure n Made of steel, finished to match fume hood superstructure n Installation hardware included n Lower front panel is removable for access to light fixture Product No. Width Height Depth 54L1201231 54L1201731 54L1202431 54L1202931 54L1203631 120” (3048 mm) 120” (3048 mm) 120” (3048 mm) 120” (3048 mm) 120” (3048 mm) 12-1/2” 17” 24-1/2” 29” 36-1/2” (318 mm) (432 mm) (622 mm) (737 mm) (927 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 54L1441231 54L1441731 54L1442431 54L1442931 54L1443631 144” (3658 mm) 144” (3658 mm) 144” (3658 mm) 144” (3658 mm) 144” (3658 mm) 12-1/2” 17” 24-1/2” 29” 36-1/2” (318 mm) (432 mm) (622 mm) (737 mm) (927 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) 31-1/4” (794 mm) n Used to enclose back of fume hood superstructure when exposed n Made of steel, finished to match fume hood superstructure n Installation hardware included n These finished backs do not fit on fume hoods with stainless steel interiors; special detailing is required Product No. 90L19200 90L19300 90L19400 90L19500 90L19600 90L19700 90L19800 90L19900 90L20000 90L20100 90L20200 90L20300 90L20400 Fume Hood Type 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) Benchtop Benchtop Benchtop Benchtop Benchtop High-line High-line High-line High-line Floor-mounted Floor-mounted Floor-mounted Floor-mounted Ceiling Enclosure Panels for Horizon n Single Enclosure Use to enclose space between ceiling and top of fume hood superstructure n All installation hardware provided n Single ceiling enclosure panel is 23-1/2” (597 mm) deep and double enclosure panel is 47” (1194 mm) deep Product No. For Hood With: Single Ceiling Enclosure 9-3/4” (248 mm) height 54L0481024 48” (1219 mm) 54L0601024 60” (1524 mm) 54L0721024 72” (1829 mm) Double Enclosure 21-3/4” (553 mm) height 54L0482224 48” (1219 mm) 54L0602224 60” (1524 mm) 54L0722224 72” (1829 mm) Double Ceiling Enclosure 9-3/4” (248 mm) height 54L0481030 48” (1219 mm) 54L0601030 60” (1524 mm) 54L0721030 72” (1829 mm) 21-3/4” (553 mm) height 54L0482230 48” (1219 mm) 54L0602230 60” (1524 mm) 54L0722230 72” (1829 mm) Installation information: With suspended ceilings, it is suggested that the enclosure assembly extend to the bottom of the ceiling. The hung ceiling should extend over the top of the fume hood and be trimmed around the mechanical connections to ensure proper room pressure control of the HVAC system. 113 Enclosures n Thermo Scientific Hamilton Air Flow Products Filler Assembly SafeAire and SafeAire II Ceiling Fillers SafeAire and SafeAire II n Enclosures Height Use to enclose space between wall and side of fume hood or space between back of fume hood and wall n Made of steel, finished to match fume hood superstructure n Installation hardware included Width Product No. Height Width For Standard Superstructure 90L15000 90L15100 90L15200 90L15300 54-1/4” (1378 mm) 54-1/4” (1378 mm) 54-1/4” (1378 mm) 54-1/4” (1378 mm) 1” (25 mm) 2” (51 mm) 3” (76 mm) 6” (152 mm) For High-line Superstructure 90L15400 90L15500 90L15600 90L15700 66-1/4” (1683 mm) 66-1/4” (1683 mm) 66-1/4” (1683 mm) 66-1/4” (1683 mm) 1” (25 mm) 2” (51 mm) 3” (76 mm) 6” (152 mm) For Floor-mounted Hood 90L15800 90L15900 90L16000 90L16100 90” 90” 90” 90” (2286 mm) (2286 mm) (2286 mm) (2286 mm) 1” (25 mm) 2” (51 mm) 3” (76 mm) 6” (152 mm) Width Height n Use to enclose space between wall and back of ceiling enclosure n Made of steel, finished to match fume hood superstructure n Installation hardware included Product No. Height 90L138N0 90L141N0 90L144N0 90L147N0 12-1/2” (318 mm) 12-1/2” (318 mm) 12-1/2” (318 mm) 12-1/2” (318 mm) 1” (25 mm) 2” (51 mm) 3” (76 mm) 6” (152 mm) Width 90L130N0 90L131N0 90L132N0 90L133N0 17” (432 mm) 17” (432 mm) 17” (432 mm) 17” (432 mm) 1” (25 mm) 2” (51 mm) 3” (76 mm) 6” (152 mm) 90L139N0 90L142N0 90L145N0 90L148N0 24-1/2” (622 mm) 24-1/2” (622 mm) 24-1/2” (622 mm) 24-1/2” (622 mm) 1” (25 mm) 2” (51 mm) 3” (76 mm) 6” (152 mm) 90L134N0 90L135N0 90L136N0 90L137N0 29” (737 mm) 29” (737 mm) 29” (737 mm) 29” (737 mm) 1” (25 mm) 2” (51 mm) 3” (76 mm) 6” (152 mm) 90L140N0 90L143N0 90L146N0 90L149N0 36-1/2” (927 mm) 36-1/2” (927 mm) 36-1/2” (927 mm) 36-1/2” (927 mm) 1” (25 mm) 2” (51 mm) 3” (76 mm) 6” (152 mm) Filler Assembly SafeAire and SafeAire II n Height Width Use to enclose space between wall and back of fume hood superstructure or floor-mounted fume hood n Made of steel, finished to match fume hood superstructure n Installation hardware included Product No. Height Width For Standard Superstructure 90L150N0 90L151N0 90L152N0 90L153N0 54-1/4” (1378 mm) 54-1/4” (1378 mm) 54-1/4” (1378 mm) 54-1/4” (1378 mm) 1” (25 mm) 2” (51 mm) 3” (76 mm) 6” (152 mm) For High-line Superstructure 90L154N0 90L155N0 90L156N0 90L157N0 66-1/4” (1683 mm) 66-1/4” (1683 mm) 66-1/4” (1683 mm) 66-1/4” (1683 mm) 1” (25 mm) 2” (51 mm) 3” (76 mm) 6” (152 mm) For Floor-mounted Fume Hood 90L158N0 90L159N0 90L160N0 90L161N0 114 90” 90” 90” 90” (2286 mm) (2286 mm) (2286 mm) (2286 mm) 1” (25 mm) 2” (51 mm) 3” (76 mm) 6” (152 mm) Installation information: With suspended ceilings, it is suggested that the enclosure assembly extend to the bottom of the ceiling. The hung ceiling should extend over the top of the fume hood and be trimmed around the mechanical connections to ensure proper room pressure control of the HVAC system. www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products For Concept and Pioneer n n Enclosure panels for front, sides and back of Concept and Pioneer fume hood superstructures n Encloses space between top of superstructure and ceiling n Made of steel, finished to match fume hood superstructure n Installation hardware included Product No. Replacement Side Enclosure Panels n Use to enclose one or both sides of Concept or Pioneer fume hood superstructures Product No. Fume Hood Depth For Standard Superstructure 54L31530FHEP 31-1/4” (794 mm) 54L37530FHEP 37-1/4” (946 mm) 54L43530FHEP 43-1/4” (1099 mm) For High-line Superstructure 54L31650FHEP 31-1/4” (794 mm) 54L37650FHEP 37-1/4” (946 mm) 54L43650FHEP 43-1/4” (1099 mm) Use to enclose space between front top and ceiling of Concept superstructure, also provides enclosure for raised sash Fume Hood Width Height 54L48170FCSE 54L48200FCSE 54L48280FCSE 54L48320FCSE 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) 54L60170FCSE 54L60200FCSE 54L60280FCSE 54L60320FCSE 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) 54L72170FCSE 54L72200FCSE 54L72280FCSE 54L72320FCSE 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) 54L84170FCSE 54L84200FCSE 54L84280FCSE 54L84320FCSE 84” (2134 mm) 84” (2134 mm) 84” (2134 mm) 84” (2134 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) 54L96170FCSE 54L96200FCSE 54L96280FCSE 54L96320FCSE 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) Front Ceiling Enclosure Panels for Pioneer n Lower Back Enclosure Panels n Use to enclose back of Concept and Pioneer fume hood superstructure Product No. Fume Hood Width For Standard Superstructure 54L48530LBEP 48” (1219 mm) 54L60530LBEP 60” (1524 mm) 54L72530LBEP 72” (1829 mm) 54L84530LBEP 84” (2134 mm) 54L96530LBEP 96” (2438 mm) For High-line Superstructure 54L48650LBEP 48” (1219 mm) 54L60650LBEP 60” (1524 mm) 54L72650LBEP 72” (1829 mm) 54L84650LBEP 84” (2134 mm) 54L96650LBEP 96” (2438 mm) Installation information: With suspended ceilings, it is suggested that the enclosure assembly extend to the bottom of the ceiling. The hung ceiling should extend over the top of the fume hood and be trimmed around the mechanical connections to ensure proper room pressure control of the HVAC system. Use to enclose space between front top ceiling/sash enclosure panel and room ceiling of Pioneer fume hood superstructure n 17-1/2” high front ceiling and sash enclosure panel is standard on Pioneer fume hood having an unframed sash n 20-1/2” high front ceiling panel is standard on combination sash fume hood Product No. Fume Hood Width Panel Height For use with 20-1/2” high side enclosure panels. For use only on unframed sash hood. 54L04803 54L06003 54L07203 54L08403 54L09603 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 3” 3” 3” 3” 3” (76 mm) (76 mm) (76 mm) (76 mm) (76 mm) For use with 28-1/2” high side enclosure panels 54L04811 54L06011 54L07211 54L08411 54L09611 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 11” 11” 11” 11” 11” (279 mm) (279 mm) (279 mm) (279 mm) (279 mm) For use with 32-1/2” high side enclosure panels 54L04815 54L06015 54L07215 54L08415 54L09615 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 15” 15” 15” 15” 15” (381 mm) (381 mm) (381 mm) (381 mm) (381 mm) 115 Enclosures Front Ceiling and Sash Enclosure Panels for Concept Thermo Scientific Hamilton Air Flow Products Left Ceiling Enclosure Panels – Bench Superstructures Upper Back Ceiling Enclosure Panels – Bench Superstructures Enclosures n Use to enclose space between lower back panel and ceiling of Concept and Hamilton Pioneer superstructure n 17-1/2” high panel is limited to Pioneer fume hood having an unframed sash n Requires front ceiling and sash enclosure, left and right ceiling enclosure panels n Use to enclose space at left side of Concept and Pioneer between lower left side panel and ceiling n 17-1/2” high panel is limited to Pioneer fume hood having an unframed sash n Requires front ceiling and sash enclosure panels Product No. Fume Hood Depth Height 54L31170LCEP 54L37170LCEP 54L43170LCEP 31-1/4” (794 mm) 37-1/4” (946 mm) 43-1/4” (1099 mm) 17-1/2” (445 mm) 17-1/2” (445 mm) 17-1/2” (445 mm) 54L31200LCEP 54L37200LCEP 54L43200LCEP 31-1/4” (794 mm) 37-1/4” (946 mm) 43-1/4” (1099 mm) 20-1/2” (521 mm) 20-1/2” (521 mm) 20-1/2” (521 mm) 54L31280LCEP 54L37280LCEP 54L43280LCEP 31-1/4” (794 mm) 37-1/4” (946 mm) 43-1/4” (1099 mm) 28-1/2” (724 mm) 28-1/2” (724 mm) 28-1/2” (724 mm) 54L31320LCEP 54L37320LCEP 54L43320LCEP 31-1/4” (794 mm) 37-1/4” (946 mm) 43-1/4” (1099 mm) 32-1/2” (826 mm) 32-1/2” (826 mm) 32-1/2” (826 mm) Right Ceiling Enclosure Panels – Bench Superstructures Product No. Fume Hood Width 54L48170UBCE 54L48200UBCE 54L48280UBCE 54L48320UBCE 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) Height 54L60170UBCE 54L60200UBCE 54L60280UBCE 54L60320UBCE 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) 54L72170UBCE 54L72200UBCE 54L72280UBCE 54L72320UBCE 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) 54L84170UBCE 54L84200UBCE 54L84280UBCE 54L84320UBCE 84” (2134 mm) 84” (2134 mm) 84” (2134 mm) 84” (2134 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) 54L96170UBCE 54L96200UBCE 54L96280UBCE 54L96320UBCE 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) n Use to enclose space at right side of Concept and Pioneer between lower right side panel and ceiling n 17-1/2” high panel is limited to Pioneer having an unframed sash n Requires front ceiling and sash enclosure panels Product No. Fume Hood Depth Height 54L31170RCEP 54L37170RCEP 54L43170RCEP 31-1/4” (794 mm) 37-1/4” (946 mm) 43-1/4” (1099 mm) 17-1/2” (445 mm) 17-1/2” (445 mm) 17-1/2” (445 mm) 54L31200RCEP 54L37200RCEP 54L43200RCEP 31-1/4” (794 mm) 37-1/4” (946 mm) 43-1/4” (1099 mm) 20-1/2” (521 mm) 20-1/2” (521 mm) 20-1/2” (521 mm) 54L31280RCEP 54L37280RCEP 54L43280RCEP 31-1/4” (794 mm) 37-1/4” (946 mm) 43-1/4” (1099 mm) 28-1/2” (724 mm) 28-1/2” (724 mm) 28-1/2” (724 mm) 54L31320RCEP 54L37320RCEP 54L43320RCEP 31-1/4” (794 mm) 37-1/4” (946 mm) 43-1/4” (1099 mm) 32-1/2” (826 mm) 32-1/2” (826 mm) 32-1/2” (826 mm) 116 Installation information: With suspended ceilings, it is suggested that the enclosure assembly extend to the bottom of the ceiling. The hung ceiling should extend over the top of the fume hood and be trimmed around the mechanical connections to ensure proper room pressure control of the HVAC system. www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Enclosure panels for front, both sides and back of Concept Floor-mounted fume hood. Encloses space between top of superstructure and ceiling n Made of steel, finished to match fume hood superstructure n Installation hardware included Enclosures n Front Ceiling and Sash Enclosure Panels for Floor-mounted Fume Hood n Use to enclose space between front top and ceiling of Concept floormounted fume hood n Provides enclosure for raised sash Product No. Fume Hood Width 54L48175FCSE 54L48205FCSE 54L48285FCSE 54L48325FCSE 54L60175FCSE 54L60205FCSE 54L60285FCSE 54L60325FCSE 54L72175FCSE 54L72205FCSE 54L72285FCSE 54L72325FCSE 54L84175FCSE 54L84205FCSE 54L84285FCSE 54L84325FCSE 54L96175FCSE 54L96205FCSE 54L96285FCSE 54L96325FCSE 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 84” (2134 mm) 84” (2134 mm) 84” (2134 mm) 84” (2134 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) Height 17-1/2” 20-1/2” 28-1/2” 32-1/2” 17-1/2” 20-1/2” 28-1/2” 32-1/2” 17-1/2” 20-1/2” 28-1/2” 32-1/2” 17-1/2” 20-1/2” 28-1/2” 32-1/2” 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) (445 mm) (521 mm) (724 mm) (826 mm) (445 mm) (521 mm) (724 mm) (826 mm) (445 mm) (521 mm) (724 mm) (826 mm) (445 mm) (521 mm) (724 mm) (826 mm) 117 Thermo Scientific Hamilton Air Flow Products Left Ceiling Enclosure Panel – for Floor Mounted Fume Hood Right Ceiling Enclosure Panel – for Floor Mounted Fume Hood Enclosures n Use to enclose space at left side of Concept Floor-mounted fume hood between lower left side panel and ceiling n Requires front ceiling and sash enclosure panels Product No. n Use to enclose space at right side of Concept Floor-mounted fume hood between lower right side panel and ceiling. n Requires front ceiling and sash enclosure panels. Fume Hood Depth Height Fume Hood Depth Height 54L35170LCEP 54L41170LCEP 54L47170LCEP 35” (889 mm) 41” (1041 mm) 47” (1194 mm) 17-1/2” (445 mm) 17-1/2” (445 mm) 17-1/2” (445 mm) 54L35170RCEP 54L41170RCEP 54L47170RCEP 35” (889 mm) 41” (1041 mm) 47” (1194 mm) 17-1/2” (445 mm) 17-1/2” (445 mm) 17-1/2” (445 mm) 54L35200LCEP 54L41200LCEP 54L47200LCEP 35” (889 mm) 41” (1041 mm) 47” (1194 mm) 20-1/2” (521 mm) 20-1/2” (521 mm) 20-1/2” (521 mm) 54L35200RCEP 54L41200RCEP 54L47200RCEP 35” (889 mm) 41” (1041 mm) 47” (1194 mm) 20-1/2” (521 mm) 20-1/2” (521 mm) 20-1/2” (521 mm) 54L35280LCEP 54L41280LCEP 54L47280LCEP 35” (889 mm) 41” (1041 mm) 47” (1194 mm) 28-1/2” (724 mm) 28-1/2” (724 mm) 28-1/2” (724 mm) 54L35280RCEP 54L41280RCEP 54L47280RCEP 35” (889 mm) 41” (1041 mm) 47” (1194 mm) 28-1/2” (724 mm) 28-1/2” (724 mm) 28-1/2” (724 mm) 54L35320LCEP 54L41320LCEP 54L47320LCEP 35” (889 mm) 41” (1041 mm) 47” (1194 mm) 32-1/2” (826 mm) 32-1/2” (826 mm) 32-1/2” (826 mm) 54L35320RCEP 54L41320RCEP 54L47320RCEP 35” (889 mm) 41” (1041 mm) 47” (1194 mm) 32-1/2” (826 mm) 32-1/2” (826 mm) 32-1/2” (826 mm) Product No. Upper Back Ceiling Enclosure Panels – for Floor Mounted Fume Hood n Use to enclose space between lower back panel and ceiling of Concept floor mounted fume hood. n 17-1/2” high panel is limited to Pioneer fume hood having an unframed sash. n Requires front ceiling and sash enclosure, left and right ceiling enclosure panels. Product No. Fume Hood Width 54L48170UBCE 54L48200UBCE 54L48280UBCE 54L48320UBCE 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 48” (1219 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) 54L60170UBCE 54L60200UBCE 54L60280UBCE 54L60320UBCE 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 60” (1524 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) 54L72170UBCE 54L72200UBCE 54L72280UBCE 54L72320UBCE 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 72” (1829 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) 54L84170UBCE 54L84200UBCE 54L84280UBCE 54L84320UBCE 84” (2134 mm) 84” (2134 mm) 84” (2134 mm) 84” (2134 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) 54L96170UBCE 54L96200UBCE 54L96280UBCE 54L96320UBCE 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 96” (2438 mm) 17-1/2” 20-1/2” 28-1/2” 32-1/2” (445 mm) (521 mm) (724 mm) (826 mm) 118 Lower Back Enclosure Panel– for Floor Mounted Fume Hood n Use to enclose back of Concept Floor-mounted fume hood. Product No. Fume Hood Width 54L48895LBEP 54L60895LBEP 54L72895LBEP 54L84895LBEP 54L96895LBEP 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) Height www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Manual Fan Motor Starter Ordering information: n Include the following information when ordering: product number, voltage, amps, watts and cycle of blower. n Magnetic Fan Motor Starter n Integral-HP magnetic AC motor starter for single and three-phase motors from 1 to 10 HP n Designed for full-voltage starting of motors n Single-phase starter for use with self-starting, single-phase motors up to 3 HP/115 volts and 7-1/2 HP/230 volts n Use with Remote Control Station for Motor Starter shown below n Protection against positive overload and low-voltage release n Heater coil not included n Must be installed in or on a wall near the fume hood n Extended lead time Product No. 36L20000 36L20100 36L20200 NEMA Contact Ratings – 60 Cycle Max HP Max HP 1-Phase 3-Phase NEMA Size Poles 115V 230V 230V 460/575V 0 0 1 2 3 3 1 – – 2 – – – 3 7-1/2 – 5 10 Manual Snap-switch Fan Motor Starter Product No. 36L19000 36L19100 36L19300 36L19400 36L19600 NEMA Contact Ratings - 60 Cycle Max HP Max HP 1-Phase 3-Phase Max. Amps. NEMA Size Poles 115V 230V 208V 240V 460V 18 18 18 18 27 0 0 0 0 1 2 2 3 3 3 1 – – – – – 2 2 – 3 – – – – – – – 3 – 7-1/2 – – – 5 – n Fractional HP manual AC motor starter for all single-phase motors up to one HP n Mounted in single gang receptacle box with flush stainless steel face plate n Double pole switch for up to 1 HP, single-phase, 60-cycle, 115/230 Vac motor n Thermal overload protection n Heater coil not included n Special order/extended lead time Product No. Remote Control Station for Motor Starter 36L20300 n Remote control station for use with Magnetic Fan Motor Starter n Vertical or horizontal mounting. n NEMA Type 1 general-purpose construction n Surface-mount station has steel base and tight-fitting wrap-around cover n Flush-mount station has stainless steel flat cover and mounting strap n Extended lead time Product No. 36L19800 36L19900 Mount Surface Flush Two-Speed Manual Motor Starter n For use with all two-speed blowers On-off selector switch for both high or low speed selection n Two on/off switches with pilot lights and thermal overload protection n NEMA Type 1, either as stainless steel plate for flush mounting, or as enclosure for surface mounting n Heater coil not included n Must be installed in or on a wall or base cabinet near the fume hood n Extended lead time n Product No. 36L20400 36L20500 Mount Surface Flush 119 Miscellaneous Accessories Integral-HP manual AC motor starter for single and three-phase motors from 1 to 10 HP n Designed for full-voltage starting of motors n Built-in start/stop buttons n Thermal overload protection n Heater coil not included n Must be installed in or on a wall near the fume hood n Extended lead time Thermo Scientific Hamilton Air Flow Products Outlets Product features n UL listed. n All fixtures on this page are ivory with chrome flush plate unless noted with: * = Black Plastic Flush Plate and Device S = Stainless Steel Flush Plate H = Hospital Grade n 240 Volt outlets are available on special order. Only flush single-faced electric outlets fit on fume hood front upright post. n Electrical fixtures are not recommended inside fume hood per NFPA-45. n Box Style Miscellaneous Accessories Receptacle Configuration Polarized 3-wire, grounding type, 120V, 20 Amp, NEMA 5-20R* Flush Single-faced Flush 2-Gang Single-faced 36L13300 36L20700* – NA – – NA – 36L15100 36L11200 36L112S0* 36L112H0 36L21200* – NA – – NA – 36L120H0 36L12000 – NA – 36L09000 36L12300 36L21300* – NA – – NA – 36L12900 36L10900 36L109S0 36L209S0 – NA – * = Black Plastic Flush Plate and Device Polarized 3-wire, grounding type 120V, 20 Amp, NEMA 5-20R * = Black Plastic Flush Plate and Device Polarized 3-wire, grounding type combination, 120V, 20 Amp, NEMA 5-20R 240 V, 15 Amp, NEMA 6-20R Polarized 3-wire, grounding type 240V, 20 Amp, NEMA 6-20R* * = Black Plastic Flush Plate and Device Polarized 3-wire, grounding type 250V, 20 Amp, NEMA 6-20R Ground Fault Interrupter n For protection against line-to-ground shock hazards. n 120V, 20 amp, NEMA-5-20R. n Flush mounted with black plastic face plate. Product No. 36L20600 120 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Switches & Pilot Lights Product features n UL listed. n All fixtures on this page are ivory with chrome flush plate unless noted with: * = Black plastic flush plate and device S = Stainless steel n For use on motor blowers up to 3/4 h.p. Pilot Light 36L13100 36L131S0 36L24400* X X X Single Volt Double 120 Amps 240 20 Miscellaneous Accessories Pole Product No. Pilot Light Only X X X – – – Toggle Switches 36L11600 36L24100* X X 36L11100 36L111S0 36L21100* 36L211S0 Lighted Toggle Switch 36L12100 36L121S0 36L12600 36L24200* 36L24300* X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Static Pressure Gauge Manometer n Used with filters in fume removal system. n Inclined vertical, liquid-filled gauge continuously measures pressure differentials to monitor filter conditions. n 0–3” WC operating range. n Assembly includes 8 feet of double tubing, two connectors, mounting screws, one bottle of red gauge oil, and instructions. n Extended lead time required for delivery. n Compact Minihelic® dial-type gauge to sense static pressure and determine airflow. n Flush- or surface-mounted with optional bracket. n Includes tube adapter, sensor set, 42” (1067 mm) long tubing and instructions. n Extended lead time. Product No. Width 54L31200 54L31300 0–1 0–3 - for use with HEPA filter Product No. 54L25600 121 Thermo Scientific Hamilton Air Flow Products Variac Voltage Transformers Vapor-proof Incandescent Light n Provides alternate interior fume hood illumination for procedures requiring vapor-proof incandescent lighting n Uses one 100-watt bulb n 120V, 60-cycle n One light is adequate for three- and four-foot fume hood; two lights recommended for five- six- and eight-foot fume hood n 3-3/4” (95 mm) diameter n 6” (152 mm) deep n Extended lead time n Designed for factory installation in the front flush panel of base cabinets to provide a variable voltage source for heating devices n ”A” suffix indicates a junction box attached to the rear of the enclosure n ”0” suffix indicates a 42” long twist-lock cord plug n Flush Variac units in base cabinets will create a nonstandard cabinet n n Includes a switch and pilot light Input – 120VAC, 50/60 Hz Output – One variable junction box 0-120VAC, 10AMP Miscellaneous Accessories Product No. Product No. 36L290S0 36L290W0 54L21400 Classified Explosion-proof Light For all steel cabinets For wood and plastic laminate cabinets n n For use in hazardous atmosphere conditions n UL listed to the following National Electric code classes: Class I – Division 1, 2 – Group C, D n Uses one 150-watt bulb n 120V, 60-cycle n One light is adequate for three and four-foot fume hood; two lights recommended for five, six and eightfoot fume hood Includes a switch and pilot light, one constant duplex electrical receptacle 120VAC 20AMP n Input – 120VAC, 50/60 Hz Output – 0-120VAC, 10AMP Product No. 36L288S0 36L288W0 36L288SA 36L288WA For all steel cabinets For wood and plastic laminate cabinets For all steel cabinets For wood and plastic laminate cabinets Product No. 54L21600 n Includes a switch and pilot light, one single electrical receptacle n Input – 120VAC, 50/60 Hz Output – one variable outlet, 0-120VAC, 10AMP Product No. 36L289S0 36L289W0 Lattice Rod Assemblies 36L289SA 36L289WA n For all SafeAire, SafeAire II, Pioneer and Concept fume hood n Solid 1/2” (13 mm) aluminum rod lattice to support interior fume hood apparatus n Fastening hardware included Product No. 26L15000 26L15100 26L15200 26L15300 Fume Hood Width 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) n For Horizon fume hood Solid 1/2” (13 mm) aluminum rod lattice – 30” (762 mm) height n Two horizontal and two vertical rods. n Fastening hardware included n Product No. 26L15800 26L15900 26L16000 122 Fume Hood Width 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) For all steel cabinets For wood and plastic laminate cabinets For all steel cabinets For wood and plastic laminate cabinets Free-Standing Variac Voltage Transformer n Variable auto-transformer free-standing module designed for installation on the counter top n Input, 120VAC, 50/60 Hz – output, 0-140VAC, 10AMP n Includes integral toggle switch, fuse holder, single electrical receptacle and power-on light n Supplied with 72” long power cord with receptacle plug Product No. 36L26700 (Special order) www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Automatic Fire Extinguisher Auxiliary Air Conversion Package Dry chemical system Includes dry chemicals, distribution piping, heads and activating link n Fume-resistant plastic finish on all exposed parts n Activating link set to operate at 300°F (148°C) n Extended lead time required for delivery n Requires field installation n Product No. Fume Hood Width Fume hood with all liners except ”S” & ”K” 54L48600 48” (1219 mm) 54L48700 60” (1524 mm) 54L48800 72” (1829 mm) 54L48900 96” (2438 mm) Fume hood with ”S” liners* 54L4860S 48” (1219 mm) 54L4870S 60” (1524 mm) 54L4880S 72” (1829 mm) 54L4890S 96” (2438 mm) Fume hood with ”K” liners* 54L4860K 48” (1219 mm) 54L4870K 60” (1524 mm) 54L4880K 72” (1829 mm) 54L4890K 96” (2438 mm) n Complete kit to convert only SafeAire Constant Volume bench-top fume hood to Auxiliary Air fume hood n Will not fit Radioisotope, Perchloric Acid or any floor-mounted fume hood Product No. 90L095N0 90L096N0 90L097N0 90L098N0 Fume Hood Width 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 96” (2438 mm) *Fume hood with ”S” & ”K” liners and Hamilton Concept are nonstandard when ordering fire extinguishers Face Velocity Labels n Mount on left or right post of vertical-rising sash fume hood n Identifies face velocity in relation to sash position n Peel-and-stick, fume- and reagent-resistant plastic material Product No. 100 FPM (black) 90L10000 90L07600 150 FPM (red) 90L10100 90L07700 Post Orientation Left Right Left Right 123 Miscellaneous Accessories n Thermo Scientific Hamilton Air Flow Products Zero-static Exhaust Outlets n Roof-top stack outlet for vertical fume hood exhaust discharge n For roof-mounted blowers only n Designed to minimize re-entrainment by ducting fumes above roof surface dead air area n Weather- and corrosion-resistant stainless steel, for weather protection without additional back-pressure n This assembly may be required by code in some states Miscellaneous Accessories Product No. For Use With Blower A B C 54L411 55L753 thru 55L758 81-7/8” (2080 mm) 16” (406 mm) 46” (1168 mm) 54L412 55L759 thru 55L766 82-1/8” (2086 mm) 16” (406 mm) 46” (1168 mm) 54L413 55L767 thru 55L772 55L785 and 55L786 87-1/8” (2213 mm) 16” (406 mm) 50” (1270 mm) 54L414 55L773 thru 55L778 55L787 and 55L788 104-1/2” (2654 mm) 16” (406 mm) 54L415 55L779 thru 55L782 55L789 111-3/8” (2829 mm) 54L416 55L783 and 55L784 55L790 120-3/4” (3067 mm) D E* F* G 9” (229 mm) 8-1/4” (210 mm) 5-3/8” (137 mm) 8” (203 mm) 10” (254 mm) 10-3/4” (273 mm) 6-1/2” (165 mm) 9” (229 mm) 11” (279 mm) 11-3/4” (298 mm) 8” (203 mm) 10” (254 mm) 62” (1575 mm) 14” (356 mm) 13-1/4” (337 mm) 9-5/8” (244 mm) 13” (330 mm) 18” (457 mm) 66” (1676 mm) 15” (381 mm) 14-3/8” (365 mm) 10-3/4” (273 mm) 14” (356 mm) 18” (457 mm) 74” (1880 mm) 17” (432 mm) 16-1/4” (413 mm) 11-3/4” (298 mm) 16” (406 mm) *Blower exhaust outlet. 124 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Combination Exhaust Collar/Transitions n Metal ductwork connecting fume hood exhaust or supply system to building exhaust or supply system n Exhaust transitions made in 22 gauge type 304 stainless steel (rectangular duct to round duct) n Supply transitions made in 22 gauge galvanized steel (round duct to rectangular duct) n Replaces standout rectangular vent exhaust collar n Cannot be used with stainless steel-lined fume hood 16” (406 mm) high Product No. Duct O.D. Exhaust transitions n For 316 stainless steel, add suffix S6 to the product number 54L90100 6” x 9” to 8” round (152 x 229 to 203 mm round) Exhaust Transition n 54L90200 6” x 15” to 10” round (152 x 381 to 254 mm round) 54L90300 6” x 23” to 12” round (152 x 584 to 305 mm round) 54L90900 6” x 26” to 12” round (152 x 660 to 305 mm Round) n Low profile transition from fume hood to duct for use where ceiling heights are lower than normal n Designed to reduce static pressure n Made of 22 gauge type 304 stainless steel n 13-1/2” (343 mm) high n Shipped separate unless ordered as nonstandard Product No. Fume Hood Width 54L91000 54L91100 54L91200 54L91800 54L91300 48” 60” 72” 84” 96” (1219 mm) (1524 mm) (1829 mm) (2134 mm) (2438 mm) Outlet Diameter Base Size 6” x 20-1/2” 6” x 26-1/2” 6” x 32-1/2” 6” x 35-1/2” 6” x 38-1/2” (152 x 521 mm) (152 x 673 mm) (152 x 826 mm) (152 x 902 mm) (152 x 978 mm) 10” 12” 12” 12” 14” (254 mm) (305 mm) (305 mm) (305 mm) (356 mm) Exhaust Filter Pack Assemblies 54L90400 6” x 30” to 14” round (152 x 762 to 356 mm round) Supply transitions n For 316 stainless steel, add suffix S6 to the product number Supply Transition n Eliminates exhaust of particulate contaminants and maintains clean conditions in duct downstream of rough filter 54L90500 9” round to 6” x 12” (203 mm round to 152 x 305 mm) n For 12” (305 mm) diameter intake and exhaust collar 54L90600 10” round to 6” x 15” (254 mm round to 203 x 381 mm) n Includes HEPA filter, rough filter and minihelic assembly 54L90700 11” round to 6” x 18” (279 mm round to 152 x 457 mm) n 54L90800 12” round to 6” x 24” (305 mm round to 152 x 610 mm) HEPA filter traps and retains particles as small as 0.3 to 0.5 microns n Access to filter exchange from front and sides n Metal frame, coated with fumeresistant powdercoat finish and steel panels, designed for inside use only n Set of replacement filters consisting of HEPA and rough filters n Requires duct transition (order separately) when mounted on top of fume hood n 1.6 total S.P. (clean) @ 1250 CFM n Extended delivery time required Exhaust Duct Transitions – for Horizon Only n Low profile transition from fume hood to duct for use where ceiling heights are lower than normal n Designed to reduce static pressure n Made of 22 gauge type 304 stainless steel n 13” (328 mm) overall height Product Numbers Product No. Fume Hood Width For single fume hood 54L91400 48” (1219 mm) 54L91400 60” (1524 mm) 54L91500 72” (1829 mm) For double fume hood 54L91600 48” (1219 mm) 54L91600 60” (1524 mm) 54L91700 72” (1829 mm) Base Size Outlet Diameter 4” x 30” (102 x 762 mm) 4” x 30” (102 x 762 mm) 4” x 30” (102 x 762 mm) 10” (254 mm) 10” (254 mm) 12” (305 mm) 9” x 30” (229 x 762 mm) 9” x 30” (229 x 762 mm) 9” x 30” (229 x 762 mm) 12” (305 mm) 12” (305 mm) 14” (356 mm) Mild Steel Frame Stainless Steel Frame Replacement Filters Width Height Depth Capacity 54L29600 54L29800 54L25400 24” 24” 24” 1300 CFM (610 mm) (610 mm) (610 mm) 54L29700 54L29900 54L30000 24” 24” 30” 1500 CFM (610 mm) (610 mm) (762 mm) 125 Miscellaneous Accessories Duct Transitions Thermo Scientific Hamilton Air Flow Products Perchloric Acid Duct Nozzle Assembly Miscellaneous Accessories Frequent washdown of perchloric systems will reduce explosion hazards. A thirty- to sixty-second washdown after fume hood usage is sufficient. Remove all apparatus from fume hood interior before washdown. Product No. Wall-hung Blower Mounting Brackets n Designed for provide a positive, fine spray for perchloric acid duct washdown n For 12” (305 mm) diameter duct; may be field cut for smaller duct diameters Provides stable base for wallmounted blowers n Includes shock-absorbing adjustable motor mounts n Installation hardware included n Brackets sold in pairs n Reference blower dimensions n Stainless steel and fluorocarbon plastic n Large nozzle orifice minimizes plugging Product No. n Installation hardware (bands, screws and fittings for 1/4” diameter IPS pipe) included 54L22000 54L22200 54L22400 n Available on extended lead time 20 1.9 30 2.3 40 2.7 Height 18” (457 mm) 25” (635 mm) 30” (762 mm) Depth 18” (457 mm) 25” (635 mm) 30” (762 mm) Blower Mounting Pads Water Volume for Each Nozzle 54L33300 Water pressure (PSI) Flow rate (GPM) n 50 3.0 60 3.3 70 3.5 80 3.8 n Neoprene vibration isolators designed to absorb vibration and maintain secure mount n Maximum deflection (under heaviest load range) is 0.30 inches Perchloric Acid Blower/Duct Drain Connection n Assembly including one set of two stainless steel and fluorocarbon plastic drains to provide connection between blower and duct for disposal of washdown waters n Stainless steel and fluorocarbon plastic n Attachment to blower scroll by screws, to duct by stainless steel bands or screws (provided) n Sized for 1/2” diameter IPS pipe n Connecting pipe not included n Available on extended lead time Locate nozzles approximately every five feet and in each elbow. Fume Hood drains will handle 30 GPM. With long duct systems, stage washdown to prevent overflow. Washdown system should drain empty through fume hood nozzles. Frequent wash- and wipe-down of perchloric systems will reduce explosion hazards and extend liner life. A 30-60 second washdown after fume hood usage is sufficient. Remove all apparatus from fume hood interior before washdown. Product No. For Use with Blower Pads/Package 54L54900 55L753 thru 55L772 55L785 and 55L786 55L773 thru 55L778 55L787 and 55L788 55L811 thru 55L814 4 54L55000 6 Silicone Duct Wrap n Fiberglass cloth provides vibration damping connection between blower and duct, or between fume hood collar and duct n Allows connector to serve as transition for differences in diameter or for minor offsets n Fume-, vapor- and condensationresistant n Installed with duct tape or silicone cement (not provided) n Not suitable for perchloric acid systems Product No. Width Length 54L33100 5”(127 mm) 72”(1829 mm) Product No. 54L33500 126 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products This page is intentionally blank. 127 Thermo Scientific Hamilton Air Flow Products Duct Work Recommended Duct Air Velocity Round ducts are more efficient and less expensive than rectangular ducts, and are highly recommended for fume hood supply and exhaust systems. Moderate duct air velocities (approximately 1600 FPM) are high enough to evaporate moisture and other condensates that might form in the duct system, but low enough to minimize static pressure and associated noise. The optimum diameter for the specific system will be determined by duct system static pressure and exhaust volume. Certain conditions may dictate the need for higher duct velocities. In these cases, an increase in static pressure and noise is to be expected. Duct Material Controlling Duct and System Noise The ideal duct material is resistant to corrosive fumes, fireproof, lightweight, low in cost and smooth on its interior surface. To minimize noise associated with a fume hood duct system, static pressure must also be minimized. (See discussion of static pressure in Understanding Fume Hood Technology, page 10.) Undersized ducts and tight duct elbows also can contribute to unacceptable noise levels. Commonly used: n Stainless Steel Types #302, 304 and 316 n Polyvinyl chloride (PVC) n Polyvinyl steel (PVS) Selecting a Fume Hood Blower Proceed through the following steps, in order presented, to select the most appropriate blower for the fume hood application. The steps required for selecting a blower are as follows: HVAC Step 1: Identifying Fume Hood Exhaust Volume & Static Pressure Loss (SPL) Step 2: Determining Optimum Duct Diameter Step 3: Calculating Total Duct Length Step 4: Calculating Duct SPL Step 5: Calculating Total System SPL Step 6: Choosing a blower with the capacity to move system exhaust volume at total system SPL Step Fume Hood Exhaust Volume & 1 Identify Static Pressure Loss (SPL) Turn to the specific product page in this catalog that describes the fume hood selected. Exhaust volume (CFM) and static pressure (SP) values are provided in the Operating Parameters chart. For definitions of exhaust volume and static pressure and their role in fume hood dynamics, refer to page 10 in Understanding Fume Hood Technology. Fume Hood Exhaust Volume (A): ______ CFM Fume Hood SPL* (B): ______ inches WG Example: The grey boxes appearing within these instructions include an example of selecting a blower for a 72” Restricted Bypass Fume Hood. Important: This process is intended only for selecting a blower for an individual fume hood/exhaust system, with the blower located on the building exterior at the discharge end of the exhaust duct. Consult with an HVAC professional to select a blower for a manifold system. 128 55L774 (Page 132) Fume Hood Exhaust Volume (A) Fume Hood SPL* (B): .18 1000 CFM inches WG * For Auxiliary Air fume hood, use the Static Pressure Value from the Supply Air Requirements chart (not the Operating Parameters chart) on the product information page of the specified unit. www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Determining the Proper Blower and Duct System Calculations for 10 Feet of Metal Duct Handling Air Diameter 2” (51 mm) 3” (76 mm) 4” (106 mm) 5” (127 mm) 6” (152 mm) 7” (178 mm) 8” (203 mm) 9” (229 mm) 10” (254 mm) 12” (305 mm) 14” (356 mm) 16” (406 mm) 18” (457 mm) 20” (508 mm) 24” (607 mm) Area (Square Inches) Area (Square Feet) 3.141 7.068 12.566 19.635 28.274 38.485 50.285 63.617 78.540 113.098 153.938 201.062 254.470 314.160 452.390 .0218 .0491 .0872 .1364 .1964 .2673 .3491 .4418 .5454 .7854 1.0690 1.3960 1.7670 2.1820 3.1420 Straight Duct Length Equivalent for 90 degree Elbows Duct diameter Linear feet 8” 15 10” 20 12” 25 14” 30 16” 36 18” 41 CFM Static Pressure Loss - WG 8” (203 mm) 8” (203 mm) 8” (203 mm) 8” (203 mm) 390 520 650 788 .025” .045” .068” .097” 1120 1490 1865 2260 10” (254 mm) 10” (254 mm) 10” (254 mm) 10” (254 mm) 10” (254 mm) 10” (254 mm) 10” (254 mm) 10” (254 mm) 10” (254 mm) 12” (305 mm) 12” (305 mm) 12” (305 mm) 12” (305 mm) 12” (305 mm) 12” (305 mm) 12” (305 mm) 12” (305 mm) 12” (305 mm) 12” (305 mm) 12” (305 mm) 12” (305 mm) 12” (305 mm) 400 570 630 760 850 950 1060 1140 1270 600 750 840 900 940 1000 1110 1250 1390 1500 1560 1670 1870 .009” .017” .021” .030” .037” .045” .056” .064” .079” .008” .011” .015” .017” .018” .020” .024” .030” .037” .043” .046” .052” .064” 735 1055 1155 1400 1580 1745 1945 2090 2330 760 950 1125 1270 1330 1375 1415 1625 1790 1900 1975 2175 2380 14” (357 mm) 14” (357 mm) 14” (357 mm) 14” (357 mm) 14” (357 mm) 14” (357 mm) 14” (357 mm) 14” (357 mm) 14” (357 mm) 14” (357 mm) 14” (357 mm) 16” (406 mm) 16” (406 mm) 16” (406 mm) 16” (406 mm) 16” (406 mm) 16” (406 mm) 16” (406 mm) 16” (406 mm) 16” (406 mm) 16” (406 mm) 16” (406 mm) 18” (457 mm) 18” (457 mm) 18” (457 mm) 18” (457 mm) 18” (457 mm) 18” (457 mm) 18” (457 mm) 18” (457 mm) 18” (457 mm) 18” (457 mm) 800 1000 1200 1430 1710 1900 2380 2140 2380 2570 2860 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 1800 2000 2200 2400 2600 2800 3000 3200 3500 3500 .006” .009” .013” .018” .026” .032” .048” .038” .048” .055” .067” .0048” .0067” .0080” .0120” .0150” .0180” .0220” .0250” .0280” .0330” .0380” .008” .010” .012” .014” .016” .019” .022” .024” .028” .028” 750 935 1125 1335 1600 1780 2230 2005 2230 2400 2730 725 875 960 1175 1300 1425 1600 1750 1875 2010 2175 1010 1175 1275 1370 1475 1600 1700 1825 2000 2000 Duct Diameter 20” 46 24” 57 Values in these charts are based on performance characteristics of round ducts. If the application requires the use of rectangular ducts, calculate the round duct diameter equivalents using the conversion information on the next page. Duct Velocity FPM HVAC Diameter and Area of a Round Duct 129 Thermo Scientific Hamilton Air Flow Products Step 2 Determine Optimum Duct Diameter Step Reference corresponding chart on previous page. Based on exhaust volume selected in Step 1, the ideal duct velocity should range from 1300 to 1600 FPM, which will help to determine the proper duct diameter. 4 Calculate Duct Static Pressure Loss (SPL) Divide total duct length (H) by 10 in order to use the values on the operating parameters table for 10 feet of duct. (H) ÷ 10 = (I) Refer to the line in the operating parameters table that was chosen in Step 3. Example: 1000 CFM Based on 10 feet of duct length the Static Pressure Loss = .020” wg (Duct Velocity = 1375 FPM) Duct Diameter Selected = 12” Multiply 10-foot duct SPL (C) by duct length (I) for total duct SPL (J) (C) x (I) = inches WG (J) Example: (H) ÷ 10 = 120 ÷ 10 = 12 10-ft lengths (I) Step 3 Calculate Total Duct Length (C) x (I) = .020 x 12 = .24 inches WG (J) Total duct length will be used in determining Duct System SPL. Length of straight duct (D): _______ linear feet (Use plan drawings for reference, if necessary.) Step Number of elbows (E): _______ 5 Determine Total System Static Pressure Loss (SPL) Length equivalent per elbow (F) (per chart below): _______ linear feet Add total Fume Hood SPL (B) to duct SPL (J) for total system SPL (K). Multiply the number of elbows (E) by the length equivalent of elbows (F) for the total elbow length equivalent (G). (B) + (J) = HVAC (E) x (F) = _______ linear feet (G) Add length of straight duct (D) to total elbow length equivalent (G) for total duct length (H). inches WG (K) Example: These two values will be required for selecting a fume hood blower. (B) + (J) = .18 + .24 = .42 inches WG (K) (D) + (G) = _______ linear feet (H) Summary Straight Duct Length Equivalent for 90o Elbows* Duct diameter .8” 10” 12” 14” 16” 18” 20” 24” Linear feet 15 20 25 30 36 41 46 57 Exhaust volume (A) = CFM Total system SPL (K) = inches WG *Based on smooth inside surface and elbows with radius 1.5 times duct diameter To calculate straight duct length equivalents for elbows with radii other than 90°, multiply the 90° equivalent from above table by the value as shown below. Elbow Radius Multiply 90o Equivalent By 60° 45° 30° .67 .50 .33 Example: Exhaust volume = 1000 Total static pressure loss = .42 Example: Length of straight duct (D): 30 linear feet Number of elbows (E): 3 elbows Length equivalent per elbow (F) = 30 (E) x (F) = 3 x 30 = 90 linear feet (G) linear feet (D) + (G) = 30 + 90 =120 linear feet (H) 130 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products 6 Select a Blower Select a blower from the next five pages with the capacity to move the system Exhaust Volume (A) at the Total System SPL (K). V-belt Drive Blowers are most desirable, as they can be adjusted to compensate for minor discrepancies in duct fabrication, room pressure and other building conditions that may cause deviations from anticipated fume hood face velocities. High-pressure Blowers feature V-belt drives and backward curved fan blades that are designed for higher static pressures. Rectangular-to-Round Duct Conversions All of the calculations in this section are based on the use of round ducts. If building conditions or other circumstances dictate the use of square or rectangular ducts, use the following chart to find the round duct diameter equivalent. Begin by finding the cross section area of the duct by multiplying height (A) by width (B). If duct area falls between the values listed in the table, choose the closest value. Direct-drive Blowers are the most economical, but offer no adjustment capabilities. To select a blower model: n Determine the preferred general operating type (V-Belt, High Pressure or Direct Drive). Turn to the appropriate product page in this catalog. n Find the total system SPL (K) in the Blower Ordering Chart. (Round up to the nearest quarter inch.) n Look vertically down the CFM column to find the total system Exhaust Volume (A). n If more than one blower model will fulfill this criteria, make a selection based on lowest motor horsepower and low RPM first, then inlet size closest to duct diameter. Ideally, the blower inlet size and duct diameter are the same. If this is not possible, choose an inlet size larger than the ductwork. n Finally, choose a blower product number for either a 115-volt or 230-volt model. Generally, motors of 3/4 HP and up operate more cost-effectively in a 230-volt configuration. B Rectangular Duct A Rectangular-To-Round Duct Equivalents Rectangular Duct Area Square Inches Square Feet Round Duct Equivalent 50.285 78.540 113.098 153.938 254.470 .349 .5454 .7854 1.0690 1.7670 8” 10” 12” 14” 18” HVAC Step Example: Round .42 to .5 for Static Pressure Loss & at 1000 CFM Blower Best Fit 55L769. 131 Thermo Scientific Hamilton Air Flow Products V-belt Drive Blowers Forward Curve n Adjustable fan speeds can compensate for variations between planned and actual duct and system characteristics. n 115-volt or 230-volt, 60-cycle, single-phase operation; other electric specifications available upon request. n Clockwise rotation standard. Contact factory for optional counterclockwise rotation. n Housing constructed of steel; fan wheel constructed of aluminum. n Housing interior and impellers coated with fume resistant finish. n Weather housing included. Caution: Advise factory if blower is for perchloric acid application, as it must be modified to eliminate organic material in airflow. Product Numbers Product No. HVAC 115-Volt Blowers 55L753 55L759 55L761 55L767 55L811 55L755 55L769 55L773 55L757 55L763 55L771 55L813 55L779 55L765 55L809 55L775 55L777 55L781 55L783 230-Volt Blowers 55L754 55L760 55L762 55L768 55L812 55L756 55L770 55L774 55L758 55L764 55L772 55L814 55L780 55L766 55L810 55L776 55L778 55L782 55L784 132 Motor HP Inlet O.D. 1/6 1/6 1/4 1/4 1/4 1/3 1/3 1/3 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 1 1 1 8” 9” 9” 10” 13-1/4” 8” 10” 13-1/4” 8” 9” 10” 13-1/4” 14-1/2” 9” 10” 13-1/4” 13-1/4” 14-1/2” 16-1/8” (203 mm) (229 mm) (229 mm) (254 mm) (337 mm) (203 mm) (254 mm) (337 mm) (203 mm) (229 mm) (254 mm) (337 mm) (368 mm) (229 mm) (254 mm) (337 mm) (337 mm) (368 mm) (410 mm) 1/6 1/6 1/4 1/4 1/4 1/3 1/3 1/3 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 1 1 1 8” 9” 9” 10” 13-1/4” 8” 10” 13-1/4” 8” 9” 10” 13-1/4” 14-1/2” 9” 10” 13-1/4” 13-1/4” 14-1/2” 16-1/8” (203 mm) (229 mm) (229 mm) (254 mm) (337 mm) (203 mm) (254 mm) (337 mm) (203 mm) (229 mm) (254 mm) (337 mm) (368 mm) (229 mm) (254 mm) (337 mm) (337 mm) (368 mm) (410 mm) Ordering information: Use the Exhaust Characteristics Table on page 133 to choose a specific blower model. n Use the Total System Static Pressure Loss (K) as the basis of selection. n Locate the Exhaust Volume value (A) for the system. n Choose an Inlet Size that is the same or slightly larger than the ductwork. n Choose the lowest possible horsepower. n Choose from 115-volt or 230-volt models. n Installation information: Refer to Blower Roughing-in Details, pages 147. n www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Exhaust Characteristics of V-belt Drive Utility Blower Blower Capacity in CFM (Cubic feet per minute) Static Pressure Loss (SP) 115 VOLT 230 VOLT Motor HP Inlet O.D. 1/4” SP CFM RPM 1/2” SP CFM RPM 3/4” SP CFM RPM 1” SP CFM RPM 55L753 55L754 1/6 8” 503 1021 658 1210 266 1081 602 1316 326 1324 555 1428 385 1529 496 1558 55L755 55L756 1/3 8” 770 1362 859 1482 645 1362 817 1568 452 1362 770 1645 385 1529 503 1729 444 1710 686 1821 474 1873 639 1923 503 2023 592 2036 55L757 55L758 1/2 8” 920 1556 998 1685 810 1556 962 1751 680 1556 918 1819 880 1556 – 1890 444 1710 844 1960 474 1873 812 2042 503 2023 710 2124 55L759 55L760 1/6 9” 725 817 819 881 421 842 761 971 515 1031 690 1075 55L761 55L762 1/4 9” 824 883 949 992 562 883 905 1056 515 1031 842 1144 608 1192 796 1242 655 1336 726 1340 55L763 55L764 1/2 9” 1141 1167 1217 1238 1080 1167 1189 1272 889 1167 1151 1325 421 1167 1111 1389 655 1331 1058 1463 749 1460 1009 1535 796 1576 960 1611 842 1684 913 1694 55L765 55L766 3/4 9” 1123 1167 1404 1412 1080 1167 1377 1433 889 1167 1350 1473 421 1167 1320 1520 655 1331 1279 1576 749 1460 1283 1638 796 1576 1191 1703 842 1684 1146 1765 55L767 55L768 1/4 10” 931 695 1166 794 636 727 1060 874 763 888 975 940 55L769 55L770 1/3 10” 931 695 1305 860 700 739 1200 926 763 888 1113 994 827 1022 1032 1059 55L771 55L772 1/2 10” 1357 883 1526 967 1081 883 1432 1031 751 883 1348 1089 827 1022 1272 1142 954 1144 1208 1198 1018 1252 1113 1261 55L809 55L810 3/4 10” 1638 1021 1763 1090 1410 1021 1688 1140 1208 1021 168 1196 827 1021 1535 1250 954 1144 1472 1297 1018 1252 1417 1344 55L811 55L812 1/4 13-1/4” 1201 545 1502 623 722 593 1330 677 944 726 1144 744 – – 55L773 55L774 1/3 13-1/4” 1201 545 1681 675 772 593 1522 721 1030 731 1352 775 55L813 55L814 1/2 13-1/4” 1544 629 1966 760 1115 629 1836 801 55L775 55L776 3/4 13-1/4” 2049 778 2284 858 55L777 55L778 1 13-1/4” 55L779 55L780 1/2 55L781 55L782 55L783 55L784 – – – – – – – – 1-1/4” SP CFM RPM – – – – – – – – 1-1/2” SP CFM RPM – – – – 1-3/4” SP CFM RPM – – – – 2” SP CFM RPM – – – – – – – – 562 2163 730 2216 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 1081 1208 1346 1393 1208 1447 1272 1453 – – – – – – – – – – – – – – – – – – 1030 1180 837 844 – – – – – – – – – – – – – – – – 1287 764 1699 844 1115 1544 840 891 1201 1395 937 950 – – – – – – – – – – – – 1716 778 2170 894 1373 778 2045 928 1287 1925 854 966 1373 948 1795 1009 1287 1025 1673 1058 1373 1107 1544 1115 – – – – 2145 817 2536 938 1888 817 2431 970 1552 817 2321 1000 1544 891 2219 1035 1544 968 2102 1070 1459 1035 1979 1107 1459 1110 1863 1151 14-1/2” 1677 594 2053 693 1355 594 1918 722 1154 669 1813 758 1364 1678 774 804 – – 1 14-1/2” 2366 778 2647 856 2137 778 2536 881 1892 778 2428 904 1372 2346 778 931 1783 2253 887 961 1678 2150 948 998 1 16-1/8” 2862 594 3291 668 2452 594 3169 696 1792 594 3018 726 1920 2856 676 758 1792 2680 740 796 2157 2496 819 837 – – – – – – – – – – 1459 1183 1750 1207 – – – – 1783 1023 2015 1039 – – – – 2048 2320 – – – – 874 884 HVAC Catalog No. 133 Thermo Scientific Hamilton Air Flow Products High-pressure Blowers Backward Curve For handling specified air volumes at higher static pressures caused by higher fume hood face velocities and extended duct runs with multiple convolutions. n Backward curved blades with high RPM settings. n 1/2 to 1 HP models available with 115/230 volt operation; 1-1/2 to 2 HP models available with 230/460 volt operation. n Clockwise rotation standard. Counterclockwise rotation available with extended delivery. (Specify rotation and discharge, voltage and current.) n Up-blast discharge standard; contact factory for optional discharge configurations. n Steel weather housing and fan wheel included. n Interior of housing and fan wheel coated with fume-resistant finish; optional coatings available. n Product Numbers Product No. Motor HP 55L785 55L786 55L787 55L788 55L789 55L790 1/2 1 1 1-1/2 1-1/2 2 Inlet O.D. 10” 10” 13-1/4” 13-1/4” 14-1/2” 16-1/8” (254 mm) (254 mm) (337 mm) (337 mm) (368 mm) (410 mm) HVAC Ordering information: n Use the Total System Static Pressure Loss (K) as the basis of selection. n Locate the Exhaust Volume value (A) for the system. n Choose an Inlet Size that is the same or slightly larger than the ductwork. n Choose the lowest possible horsepower. n Choose from 115-volt or 230-volt models. n Support bracket required for blowers with inlet O.D. 13-1/4” (337 mm) or larger. Installation information: Refer to Blower Roughing-in details. n Exhaust Characteristics –High Pressure Blowers Blower Capacity Motor HP Inlet O.D. 3/4” SP CFM RPM 1” SP CFM RPM 1-1/4” SP CFM RPM 1-1/2” SP CFM RPM 1-3/4” SP CFM RPM 55L785 1/2 10” 880 1766 1386 2380 731 1766 1310 2390 827 1985 1246 2404 827 2116 1176 2423 763 2196 1081 2435 827 1002 2354 2477 700 2507 827 2573 55L786 1 10” 1218 2178 1876 3012 1135 2178 1805 3006 1040 2178 1739 3008 904 2178 1678 3015 890 2282 1620 3022 954 1566 2441 3028 954 2651 1450 3059 827 2776 1311 3101 55L787 1 13-1/4” 1447 1634 2276 2272 1286 1634 2170 2260 1030 1599 2059 2251 1373 1834 1974 2264 1115 1860 1854 2258 1030 1759 1966 2272 1030 2187 1544 2303 1115 2397 1201 2401 55L788 1-1/2 13-1/4” 1627 1766 2696 2607 1490 1766 2574 2581 1321 1766 2507 2590 1152 1766 2412 2578 1201 1885 2329 2584 1287 2231 2021 2581 1201 2201 2059 2600 1459 2438 1875 2625 55L789 1-1/2 14-1/2” 1888 1556 3003 2214 1730 1556 2893 2205 1522 1556 2777 2200 1154 1556 2663 2196 1201 1885 2553 2198 1287 2442 2021 2202 1201 2201 2203 2222 1459 2438 1927 2259 2518 1390 4096 2032 2308 1390 3931 2014 2038 1390 3830 2022 1451 1390 3661 2005 2304 1624 3527 2003 2176 3375 1675 2002 1792 1782 3072 2021 1792 1937 2650 2051 Product No. 55L790 134 2 16-1/8” 2” SP CFM RPM 2-1/2” SP CFM RPM 3” SP CFM RPM — — — — www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Direct Drive Blowers Basic Blower Models For use when CFM exhaust requirements need not be exact, and when space and budget are limited. n Recommended for use with a balance damper. (supplied by other) n Backward curved blades with high RPM settings. n 115-volt or 230-volt, 60-cycle, single-phase operation; other electric specifications available. n Low-pressure and high-pressure units available. n Permits simplified mounting for any angle of discharge; discharge position changeable in field. n Blower housing made of steel; fan wheel made of aluminum. Models 55L791–55L796 have steel fan wheel. n Interior of housing and fan wheel coated with fume-resistant finish; optional coatings available. n Optional weather housing recommended for outdoor use. n Product Numbers – Low Pressure Models Motor HP 115-volt blowers 55L791 55L793 55L795 55L797 55L799 55L801 55L803 230-volt blowers 55L792 55L794 55L796 55L800 55L802 55L804 55L805 Product Numbers – High Pressure Models RPM 1/4 1/4 1/4 1/4 1/3 1/3 3/4 1750 1150 1750 1150 1750 1150 1150 1/4 1/4 1/4 1/3 1/3 3/4 2 1750 1150 1750 1750 1150 1150 1150 Product No. Motor HP RPM 1 1150 1 2 1750 1150 115-volt blowers 55L806 230-volt blowers 55L807 55L808 Ordering information: n Use the Total System Static Pressure Loss (K) as the basis of selection. n Determine if a high-pressure or low-pressure blower would best fit the application. n Locate the Exhaust Volume value (A) for the system. n Choose an Inlet Size that is the same or slightly larger than the ductwork. n Choose the lowest possible horsepower. n Choose from 115-volt or 230-volt models. HVAC Product No. Installation information: Refer to Blower Roughing-in details. n Exhaust Characteristics –Low Pressure Models Product No. Blower Capacity 115 Volt 230 Volt Motor HP Fan RPM Free Air CFM RPM 1/8” SP CFM RPM 1/4” SP CFM RPM 3/8” SP CFM RPM 1/2” SP CFM RPM 55L791 55L793 55L795 55L797 55L799 55L801 55L803 – 55L792 55L794 55L796 – 55L800 55L802 55L804 55L805 1/4 1/4 1/4 1/6 1/3 1/3 3/4 2 1750 1150 1750 1150 1750 1150 1150 1150 184 390 595 760 1150 1180 1260 3350 169 330 560 680 1085 1160 1970 3275 144 250 515 620 1050 1125 1870 3195 112 100 470 535 1005 1090 1800 3115 – – 420 430 960 1035 1710 3025 1630 1880 2865 2570 3885 2520 3240 3900 1500 1590 2700 2300 3665 2480 3095 3815 1275 1205 2480 2095 3550 2400 2940 3725 995 480 2265 1810 3400 2325 2830 3630 – – 2025 1455 3240 2210 2690 3530 5/8” SP CFM RPM – – 365 – 915 963 1605 2940 – – 1760 – 3090 2060 2525 3430 3/4” SP CFM RPM 1” SP CFM RPM 1-1/4” SP CFM RPM – – 300 – 865 855 1500 2850 – – 1445 – 2920 1825 2355 3320 – – – – – – – – 750 2535 – – 1290 2030 2660 3100 – – – – 580 – 1020 2450 – – – – 1960 – 1605 2855 Exhaust Characteristics –High Pressure Models Product No. 115 Volt 230 Volt 55L806 55L807 – 55L808 Blower Capacity Motor HP Fan RPM Free Air CFM RPM 1/8” SP CFM RPM 1/4” SP CFM RPM 3/8” SP CFM RPM 1/2” SP CFM RPM 5/8” SP CFM RPM 3/4” SP CFM RPM 1” SP CFM RPM 1-1/4” SP CFM RPM 1 2 1750 1750 1720 3670 2910 4510 1675 3580 2800 4380 1620 3460 2680 4150 1550 3310 2550 3900 1445 3085 2415 3795 1290 2755 2240 3520 1100 2345 2130 3345 – – 1990 3130 – – 1850 2910 135 Thermo Scientific Hamilton Air Flow Products For V-belt Drive Blowers Support bracket required on blowers with 13-1/4” O.D. inlet and larger. Z L BB AA Outlet J G DD N M P I CC AA K F A BB P Foundation Plan C R L Z AA E O.D. O H H H P B D X W B D Up Blast Discharge (UBD) M N Top Angular Up Discharge (TAUD) M N Top Horizontal Discharge (THD) AA AA H H H AA H AA M N Top Angular Down Discharge (TAAD) M N Down Blast Discharge (DBD) M N Bottom Horizontal Discharge (BHD) M N Bottom Angular Up Discharge (BAUD) V-Belt Drive Blowers viewed from ”Drive” Side Blower Product No. HVAC Diameter A B C D E F G H I J K L M N O P R W Z AA BB CC DD 55L753 thru 55L758 20-7/8” 5-5/8” 3” 6-7/16” 4-5/8” 6-7/8” 5-3/8” 14” 8” 7-7/8” 6” 4-3/16” 11-1/4” 12-7/8” 6-3/4” 9/16” 1-1/2” 23-7/16” 11” 8-1/4” – – – 55L767 thru 55L772 55L759 thru 55L766 21-1/8” 6-1/4” 3” 7” 5-5/8” 7-1/8” 6-1/2” 14” 9” 9-3/16” 6-3/4” 4-3/16” 12-1/2” 14” 7-3/4” 9/16” 1-1/2” 24-5/8” 11” 10-3/4” – – – 55L773 thru 55L778 55L809 and 55L810 22-1/8” 7-1/4” 3” 7-13/16” 6-3/4” 8-1/8” 8” 14” 10” 10-11/16” 7-7/8” 5-19/32” 14-1/2” 15-5/8” 9-1/8” 9/16” 1-1/2” 26-7/32” 11” 11-3/4” – – – 55L811 thru 55L814 27-1/2” 8-3/4” 3” 9-1/2” 8-1/2” 10-1/2” 9-5/8” 17” 13-1/4” 13-1/4” 10-1/8” 6-15/32” 17-1/2” 19” 11-1/2” 9/16” 1-1/2” 28-11/32” 11” 13-1/4” 5-5/8” 14-3/4” 16-3/8” 55L779 thru 55L782 28-3/8” 9-3/4” 3” 10-1/2” 9-3/8” 11-3/8” 10-3/4” 17” 14-1/2” 14-3/8” 11-1/8” 6-15/16” 19-1/2” 21” 12-5/8” 9/16” 1-1/2” 29-7/16” 11” 14-3/8” 6-3/16” 16” 17-5/8” 55L783 and 55L784 29-3/4” 10-5/16” 3” 11-1/16” 10-3/8” 12-3/8” 11-3/4” 17-3/8” 16-1/8” 16-1/4” 12-3/8” 7-7/16” 20-5/8” 22-1/8” 14-1/8” 9/16” 1-1/2” 30-7/16” 11” 16-1/4” 16-11/16” 17-5/8” 19-1/4” Dimensions shown are nominal. Some variations may occur in manufacturing and installation. 136 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products For High Pressure Blowers n n Support bracket required on blowers with 13-1/4” O.D. inlet and larger. Inlet and outlet designed for slip connections. AA Outlet J G I AA K F O.D. AA E A O P C R BB Z L H H H P M N Top Angular Up Discharge (TAUD) B B D D Up Blast Discharge (UBD) X W M N Top Horizontal Discharge (THD) AA H AA H H AA H AA M N Top Angular Down Discharge (TAAD) M N Down Blast Discharge (DBD) M N Bottom Horizontal Discharge (BHD) M N Bottom Angular Up Discharge (BAUD) High-pressure Blowers viewed from ”Drive” Side Blower Product No. 55L785 and 55L786 22-1/16” 7-1/4” 3” 7-13/16” 6-11/16” 8-1/16” 8” 14” 10” 10-3/4” 7-7/8” 5-19/32” 14-1/2” 15-5/8” 9-1/8” 9/16” 1-1/2” 26-7/32” 5-1/8” 11” 11-3/4” – 55L787 and 55L788 27-1/2” 8-3/4” 3” 9-1/2” 8-1/2” 10-1/2” 9-5/8” 17” 13-1/4” 13-1/4” 10-1/8” 6-15/32” 17-1/2” 19” 11-1/2” 9/16” 1-1/2” 28-11/32” 6-3/8” 11” 13-1/4” 5-5/8” 55L789 28-3/8” 9-3/4” 3” 10-1/2” 9-3/8” 11-3/8” 10-3/4” 17” 14-1/2” 14-3/8” 11-1/8” 6-15/16” 19-1/2” 21” 12-5/8” 9/16” 1-1/2” 29-7/16” 7” 11” 14-3/8” 6-3/16” 55L790 29-3/4” 10-5/16” 3” 11-11/16” 10-3/8” 12-3/8” 11-3/4” 17-3/8” 16-1/8” 16-1/4” 12-3/8” 7-7/16” 20-5/8” 22-1/8” 14-1/8” 9/16” 1-1/2” 30-3/8” 7-1/16” 11” 16-1/4” 6-1/16” HVAC Diameter A B C D E F G H I J K L M N O P R W X Z AA BB Dimensions shown are nominal. Some variations may occur in manufacturing and installation. 137 Thermo Scientific Hamilton Air Flow Products For Direct-drive Blowers n n Housing permits simplified mounting for angle of discharge. Discharge position can be easily changed in the field. L K 1-1/16” J M O H D P C R E E X V N A F B W G Direct-drive Blowers Blower Product No. 55L791 and 55L792 55L793 thru 55L796 55L797 thru 55L799 55L801 and 55L802 55L806 and 55L807 55L803 and 55L804 55L808 55L805 9” x 4-1/4” 12-1/8” 8” 10-3/4” 6-1/2” 5-3/8” 7” 1/2” 6-3/4” 5-3/8” 7-3/4” 7-1/8” 16-1/8” 3/8” 4-3/8” 9” 9-1/4” – – 9-7/8” 10-5/8” x 5-1/4” 14-3/4” 11-1/2” 11-3/4” 8” 6-7/8” 10” 3/4” 8” 6-3/4” 9-1/8” 8-1/8” 16-1/2” 3/8” 5” 10” 10-3/4” – – 11-1/4” 12-1/4” x 6-1/2” 16-3/8” 13” 13-1/4” 9-5/8” 7-3/8” 9-3/4” 2-1/2” 10-1/8” 8-1/2” 11-1/2” 10-1/2” – 3/16” 6-1/2” 13-1/4” 13-1/4” 11-1/4” 11-1/4” 17” Wheel HVAC Diameter A B C D E F G H J K L M* N O P R V W X 4-1/2” x 2-1/2” 8-3/8” 7” 5-1/8” 3-3/8” 3-3/4” 6” 1/2” 3-1/2” 3-1/8” 3-3/4” 4-1/8” 9-7/8” 3/8” 2-3/4” 5” 4-5/8” – – 8-1/2” 6” x 3” 9-3/8” 8” 7-3/8” 4-1/4” 4-1/4” 7” 1/2” 5” 4” 6” 5” 10-7/8” 3/8” 3-1/4” 6” 7-1/8” – – 8-1/2” 7-5/8” x 3-5/8 11” 8” 8-1/4” 5-3/8” 5” 7” 1/2” 6” 4-5/8” 6-3/4” 6-7/8” 10-7/8” 3/8” 3-3/4” 8” 8” – – 8-1/2” *Varies with motor. Dimensions shown are nominal. Some variations may occur in manufacturing and installation. 138 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Typical Front Views Unless otherwise noted these dimensions apply to all SafeAire, SafeAire II, Advantage, Infinity, Concept and Pioneer fume hoods. A Concept 89.5” SafeAire 90” 4-13/16” B 4-13/16” Superstructures 4-13/16” B 4-13/16” A Fume Hood Width Superstructure A Superstructure B High-line Superstructure A High-line Superstructure B Floor-mounted A Floor-mounted B 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 120” (3048 mm) 144” (3658 mm) 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) 120” (3048 mm) 144” (3658 mm) 26-3/8” (670 mm) 38-3/8” (975 mm) 50-3/8” (1279 mm) 62-3/8” (1584 mm) 74-3/8” (1889 mm) 86-3/8” (2194 mm) 111-5/8” (2835 mm) 135-5/8” (3445 mm) 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) — — 26-3/8” (670 mm) 38-3/8” (975 mm) 50-3/8” (1279 mm) 62-3/8” (1584 mm) 74-3/8” (1889 mm) 86-3/8” (2194 mm) — — 36” (914 mm) 48” (1219 mm) 60” (1524 mm) 72” (1829 mm) 84” (2134 mm) 96” (2438 mm) — — 26-3/8” (670 mm) 38-3/8” (975 mm) 50-3/8” (1279 mm) 62-3/8” (1584 mm) 74-3/8” (1889 mm) 86-3/8” (2194 mm) — — 139 Technical Floor-mounted Thermo Scientific Hamilton Air Flow Products Typical End Views These dimensions apply to general-purpose and special-purpose fume hood unless otherwise noted on specific fume hood catalog page. 36” 5-5/16” 31-1/4” 5-5/16” 37-1/4” 5-5/16” 43-1/4” 5-5/16” 29” 34” 19” 53” 47-11/16” 28-1/2” Sash Opening 59-1/2” Sash Open 28” 22” 1-1/4” 36-1/2” Steel 36” Wood 7” 1” 22” 30” 11-3/4” 22” 34-3/4” SafeAire II Standard Bench 54-Series 1” 13” 36” 5-5/16” 31-1/4” 5-5/16” 1” 42” Extended Depth Fume Hood 61-Series 60-Series 22” 19” 1” 22” 36” 62-Series 37-1/4” 5-5/16” 43-1/4” 5-5/16” 29” 34” 65” 59-11/16” 28-1/2” Sash Opening (35” Optional) 28” 22” 1-1/4” 36-1/2” Steel 36” Wood 7” 11-3/4” 1” 22” 30” Technical SafeAire II Standard Bench High-line 54-Series 5-5/16” 22” 34-3/4” 1” 13” 22” 36” 1” 42” Extended Depth Fume Hood 61-Series 60-Series 22” 19” 1” 62-Series 5-5/16” 5-5/16” 31” 37” 38-11/32” 44-11/32” 100-11/16” 31-1/2” Sash Opening 84-11/16” 90” 66-1/2” Both Sashes Open 25” 32-11/32” SafeAire Floor-mounted 554-Series 140 Extended Depth Fume Hood 551-Series 552-Series www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products SafeAire Auxilairy Air Typical End Views These dimensions apply to general-purpose and special-purpose fume hood unless otherwise noted on specific fume hood catalog page. 44-5/16” 39-19/64” 5-5/16” 49-1/16” 44-3/64” 50-5/16” 45-19/64” 5-5/16” 5-5/16” 56-5/16” 51-19/64” 5-5/16” 18-7/32” 19” 24-3/8” 23-3/4” 31” 44” 27-1/2” 62-7/16” Sash Opening 47-11/16” 35-13/16” 1-1/4” 7” 29” 28” 23-1/2” 22” 30” 11-3/4” 1” Standard Bench Superstructure 54-Series 44-5/16” 39-19/64” 39-13/16” 38-9/16” 1” 36-1/2” Steel 36” Wood 22” 34-3/4” 13” 1” 36” 49-1/16” 44-3/64” 1” 19” 1” 22” 42” 62-Series 56-5/16” 51-19/64” 50-5/16” 45-19/64” 5-5/16” 5-5/16” 22” 45-13/16” Extended Depth Fume Hood 61-Series 60-Series 1-13/32” 35-1/2” 5-5/16” 5-5/16” 18-7/32” 19” 13-3/4” 24-3/8” 28” 29” 31” 56” 59-11/16” 27-1/2”Sash Opening (35” Opt.) 23-1/2” 1-1/4” 1” 33-13/16” 35-1/2” 39-13/16” 38-9/16” 45-13/16” 36-1/2” Steel 36” Wood 22” 30” 1” 11-3/4” Standard Bench High-line Superstructure 54-Series 22” 34-3/4” 60-Series 1” 13” 22” 1” 5-5/16” 22” 1” 42” Extended Depth Fume Hood 61-Series 46-7/16” 40-7/16” 19” 36” Technical 7” 62-Series 52-7/16” 5-5/16” 5-5/16” 31” 37” 41” 47” 18-7/32” 10-1/2” 99-7/16” 31-1/2” Sash Opening 84-11/16” 79-13/16” 66-1/2” Both Sashes Open 25” 35” Floor-mounted 554-Series 101-3/8” to Open Sash Extended Depth Fume Hood 551-Series 552-Series 141 Thermo Scientific Hamilton Air Flow Products Typical End Views These dimensions apply to general-purpose and special-purpose fume hood unless otherwise noted on specific fume hood catalog page. 35-3/4" (908 mm) 41-3/4" (1061 mm) 37-1/4" (946 mm) 31-1/4" (794 mm) 5-5/16" (135 mm) 5-5/16" (135 mm) 69.5" (1765mm) Combination Sash Open 53" (1346 mm) 24" (610 mm) Combination Sash Open 22" (559 mm) 35" (889 mm) Viewing Height 28" (711 mm) 33-1/4" (845 mm) 22" (559 mm) 29" (737 mm) 17" (432 mm) 13" (330 mm) 22" (559 mm) 35" (889 mm) Concept ADA Fume Hood Assemblies 54-Series 61-Series 8-1/2” (216 mm) 8-1/2” (216 mm) 33-1/2” (815 mm) Deep Hood 39-1/2” (1003 mm) Deep Hood 69” (1753 mm) 69” (1753 mm) 68” (1727 mm) Combo Sash Open 68” (1727 mm) Combo Sash Open 60” (1524 mm) Technical 22” (559 mm) Lock Open Combo 26” (559 mm) Lock Open Vertical Rising 22-3/4” (578 mm) 33-1/2” (851 mm) 22” (559 mm) Lock Open Combo 26” (559 mm) Lock Open Vertical Rising 8-3/4" (222 mm) (55922"mm) 30-3/4" (781 mm) 39-1/2” (1003 mm) 68-3/5" (1742 mm) 26” Max Sash Open 34" (834 mm) Interior 14-3/4" 36-3/4" (933 mm) 44-1/2" (1130 mm) Interior 43” (1092 mm) Viewing Height 28-3/4” (730 mm) Advantage Hood Side View 56-Series 142 60” (1524 mm) 43” (1092 mm) Viewing Height 26” Max Sash Open 22" (559 mm) Advantage Hood Side View 59-Series 39-3/5" (1006 mm) 14-3/4" 22" (559 mm) 36-3/4" (933 mm) Infinity Hood Side View 59-Series www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Concept Typical End Views 35-3/4” (908 mm) 41-3/4” (1061 mm) 37-1/4” (946 mm) 31-1/4” (794 mm) 5-5/16” (135 mm) 53” (1346 mm) 22” (559 mm) 63-1/2” (1613 mm) Unframed Sash Open 69-1/2” (1765 mm) Combination Sash Open 28-1/2” (724 mm) Vert. Sash Open 24” (610 mm) Comb. Sash Open 41-3/4” (1061 mm) 37-1/4” (946 mm) 47-3/4” (1213 mm) 43-1/4” (1099 mm) 5-5/16” (135 mm) 5-5/16” (135 mm) 35” (889 mm) Viewing Height 28” (711 mm) 5-5/16” (135 mm) 35” (889 mm) Viewing Height 34” (864 mm) 53” (1346 mm) 70-1/2” (1791 mm) with Vert. Sash 73-1/2” (1867 mm) with Combination Sash 35” (889 mm) Viewing Height 28” (711 mm) 22” (559 mm) 29” (737 mm) 13” (330 mm) 22” 19” (483 mm) (559 mm) 41” (1041 mm) 22” (559 mm) 35” (889 mm) Concept Fume Hood Assemblies 61-Series 54-Series 27-1/2” (699 mm) Sash Open 36-1/2” (927 mm) Steel 36” (914 mm) Wood 36-1/2” (927 mm) Steel 36” (914 mm) Wood 7” (178 mm) 17-1/2” (445 mm) with Vert. Sash 20-1/2” (521 mm) with Combination Sash 39-10/16” (1006 mm) 5-15/16” (151 mm) 8-3/8” (213 mm) 22” (559 mm) 30-3/8” (772 mm) Pioneer Fume Hood Assemblies 61-Series 62-Series 45-1/32” (1158 mm) 51-19/32” (1311 mm) 28-1/2” (724 mm) 34-1/2” (876 mm) 24-1/2” (622 mm) 30-1/2” (775 mm) 36-1/2” (927 mm) 35” (889 mm) 41” (1041 mm) 47” (1194 mm) 102” (2591 mm) Unframed Sash Open 108” (2743 mm) Combination Sash Open 89-1/2” (2273 mm) 22-1/2” (572 mm) 66-1/2” (1689 mm) Concept Floor-mounted Fume Hood Assemblies 551-Series 35-3/4” (908 mm) 41-3/4” (1061 mm) 37-1/4” (946 mm) 31-1/4” (794 mm) 5-5/16” (135 mm) 65” (1651 mm) 22” (559 mm) 71” (1803 mm) Unframed Sash Open 76” (1930 mm) Combination Sash Open 28-1/2” (724 mm) Lock Open 47-3/4” (1213 mm) 43-1/4” (1099 mm) 5-5/16” (135 mm) 28” (711 mm) 552-Series Technical 554-Series 5-5/16” (135 mm) 38” (965 mm) Viewing Height 34” (864 mm) 38” (965 mm) Viewing Height 36-1/2” (927 mm) Steel 36” (914 mm) Wood 7” (178 mm) 22” (559 mm) 29” (737 mm) 54-Series 13” (330 mm) 22” (559 mm) 35” (889 mm) 19” 22” (483 mm) (559 mm) 41” (1041 mm) Concept Hi-line Fume Hood Assemblies 61-Series 62-Series 143 Thermo Scientific Hamilton Air Flow Products For Pre-piped Fume Hood General information: n Fume hood service line connections for water, waste, gas, air and vacuum will vary, depending on the point of origin and number of services provided. n Services may be brought up from below, through the floor, or down from the ceiling through the fume hood wall. n Any other method of supplying services may require special scribing or installation procedures Product information: n Pre-piped fume hood include plumbing to elbow or to bottom or top of fume hood as specified. Typical Layout Pre-piped and pre-wired fume hood installation, Show in roughed-in from above. n Material selections are as follows: Water pipe – copper Air pipe – copper (standard); black iron (optional) Gas pipe – black Iron Vacuum pipe – copper (standard); black iron (optional) Installation information: n Piping and connectors required for final connection to building lines are not furnished. n Because of code requirements and variable building conditions, connection components should be furnished by appropriate contractor. n Refer to roughing-in details for the specific type of fume hood for location of service outlets. Standard Configurations – The four pre-piped configurations below are available with standard pricing and lead times Piped to Turned-up Elbow Piped to Turned-down Elbow 6’’ Technical 6’’ Piped to Top of Fume Hood Piped to Bottom of Fume Hood W – 1-1/2” O.D. Waste 144 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products For Pre-wired Fume Hood Product information: n Pre-wired electrical service connections are available as an option and must be ordered separately. n All electrical services in fume hood post are pre-wired to a single junction box on top of fume hood. n All electrical services for items included in base cabinet(s) must be ordered separately. (e.g. VARIACS.) n Contact your Thermo Fisher Scientific representative for pricing and delivery information. Installation information: n Fume Hood ordered with pre-wired option will have all electrical services in fume hood post pre-wired to a single junction box on top of the fume hood. Pre-wired Fume Hood Junction Box Factory Pre-wiring of Standard Fume Hood Used as a pre-wire line for the standard set of electrical devices on any standard fume hood superstructure. One line is required for each device. In addition, it may be used to pre-wire one (1) additional standard, cataloged, 36L series product on each fume hood corner post. Please note that two-gang devices are not included, as these items will not fit in a standard fume hood corner post. This product number does not represent a product that can be ordered by itself. The product should be used in conjunction with a fume hood superstructure ordered with a fixture location sheet. Technical Standard attached fume hood safety monitors do not require a pre-wire line. Product No. 54L79900 145 Technical Thermo Scientific Hamilton Air Flow Products For Bench Fume Hood Dimensions – all bench fume hood except auxiliary air: Dimensions – bench auxiliary air fume hood only: n Top of exhaust vent: Bench Hood 88-1/4” (2242 mm) above finished floor with steel base. 87-3/4” (2229 mm) above finished floor with wood base. n Top of supply inlet: 98-15/16” (2513 mm) above finished floor with steel base. 98-7/16” (2500 mm) above finished floor with wood base. n Duct connection must overlap inlet by maximum of 1-7/8” (48 mm). n Top of exhaust vent: Bench High-line Hood 100-1/4” (2546 mm) above finished floor with steel base. 99-3/4” (2534 mm) above finished floor with wood base. n Duct connection must overlap vent by maximum of 1-1/4” (32 mm). (See page 125 for Duct Transition.) Symbols: CW – Cold Water HW – Hot Water G – Gas A – Compressed Air V – Vacuum W – Waste AC – 115 or 230 Volt 5” 1-1/4” CW G A AC115V V CW G A AC115V V 1-1/4” 1-1/4” 31-1/4” Air Foil 6” x 9” Fume Vent 18” 5” 5” CW G A V 39-19/64” Auxiliary Air 48” Wide Bench Fume Hood 1-1/4” 39-19/64” Auxiliary Air 5-5/16” CW G A 6” x 23” V Fume Vent CW G A AC115V V 1-1/4” 31-1/4” Air Foil 44-5/8” Auxiliary Air 48” 36” Wide Bench Fume Hood 5” CW G 6” x 15” A Fume Vent V 24” 6” x 12” Supply Inlet 36” 5” 5-5/16” 30” 6” x 15” Supply Inlet 5” 5” 1-1/4” 31-1/4” Air Foil 44-5/8” Auxiliary Air 1-1/4” 39-19/64” Auxiliary Air CW G A 6” x 23” V Fume Vent 36” 6” x 18” Supply Inlet 60” Technical 1-1/4” 72” Wide Bench Fume Hood 5-5/16” CW G A AC115V V 6” x 26” Fume Vent 42” 84” 84” Wide Bench Fume Hood Concept and Pioneer Only 5” CW G A V 5” 1-1/4” 1-1/4” 5-5/16” CW G A AC115V V 6” x 30” Fume Vent 39-19/64” Auxiliary Air 31-1/4” Concept 37-1/4” Concept & Pioneer 43-1/4” Concept n Optional depth fume hood – add either 4.75”, 6.00” or 12.00” to overall depth dimension. n See page 147 for details relating to rough-in from above fume hood. 146 1-1/4” 31-1/4” Air Foil 44-5/8” Auxiliary Air 72” 60” Wide Bench Fume Hood 5” 5” 5-5/16” CW G A AC115V V 48” CW G A V 6” x 24” Supply Inlet 96” 96” Wide Bench Fume Hood www.thermo.com/hamilton 5” 1-1/4” 31-1/4”. Air Foil 44-5/8” Auxiliary Air Thermo Scientific Hamilton Air Flow Products For Floor-mounted Fume Hood Dimensions – all floor-mounted fume hood except auxiliary air: n Top of exhaust vent is 88-7/16” (2246 mm) above finished floor (87-15/16” [2237mm] for Concept). n Duct connection must overlap vent by maximum of 1-1/4” (32 mm). (See page 125 for Duct Transition.) Symbols: CW – Cold Water HW – Hot Water G – Gas A – Compressed Air V – Vacuum W – Waste AC – 115 or 230 Volt Dimensions – Floor-mounted auxiliary air fume hood only: n Top of supply inlet 99-7/16” (2526 mm) above finished floor. n Duct connection must overlap inlet by maximum of 1-7/8” (48 mm). Waste roughing-in indicated on this center line 28” above finished floor in wall. 2” diameter hole to be cut in end panel support bracket at same location as waste line roughing-in. 43-1/4” 6” x 15” Fume Vent 2-3/8” 5-5/16” 5” CW G A V AC115V 1-1/4” 40-7/16” Auxiliary Air CW G A V 24” 6” x 12” Supply Inlet 2-3/8” Only When Required 2-3/8” 5-5/16” 5” 5” 1-1/4” 32-11/16” Air Foil 45-7/16” Auxiliary Air 1-1/4” 40-7/16” Auxiliary Air 55-1/4” 6” x 23” Fume Vent CW G A V AC115V 2-3/8” Only When Required CW G A V 5” 30” 6” x 15” Supply Inlet 48” 48” Wide Floor-mounted Fume Hood 1-1/4” 32-11/16” Air Foil 45-7/16” Auxiliary Air 60” 60” Wide Floor-mounted Fume Hood Waste roughing-in indicated on this center line 28” above finished floor in wall. 2” diameter hole to be cut in end panel support bracket at same location as waste line roughing-in. 67-1/4” 5-5/16” 5” 40-7/16” Auxiliary Air 1-1/4” 2-3/8” Only When Required 6” x 23” Fume Vent CW G A V CW G A V AC115V 36” 5” 1-1/4” 32-11/16” Air Foil 45-7/16” Auxiliary Air 6” x 18” Supply Inlet 2-3/8” 5-5/16” 5” CW G A V AC115V 1-1/4” 40-7/16” Auxiliary Air CW G A V 48” 72” 2-3/8” Only When Required 91-1/4” 6” x 30” Fume Vent 6” x 24” Supply Inlet 5” 1-1/4” 32-11/16” Air Foil 45-7/16” Auxiliary Air 96” 72” Wide Floor-mounted Fume Hood 2-3/8” Technical 2-3/8” 96” Wide Floor-mounted Fume Hood Back of Fume Hood n Optional depth Fume Hood – add either 6” or 12” to overall depth dimension. n Waste on Concept Fume Hood is located on the floor in either sideport – or 9” off the floor if routed to the back. 24” 2-1/2” Typical Rough-in Free Area (Left side shown, right side similar) 147 Thermo Scientific Hamilton Air Flow Products For Postless Sash Fume Hood Dimensions – all postless sash fume hood: n Top of exhaust vent: 88-1/4” (2242 mm) above finished floor with steel base. 87-3/4” (2229 mm) above finished floor with wood base. n Duct connection must overlap inlet by maximum of 1-1/4” (32 mm). n Suggested roughing-in dimensions are from floor. 5” 1-1/4” CW G A V AC115V 36” 6” x 23” Fume Vent Symbols: CW – Cold Water HW – Hot Water G – Gas A – Compressed Air V – Vacuum W – Waste AC – 115 or 230 Volt 5” 5” CW G A V 1-1/4” 1-1/4” CW G A V AC115V 31-1/4” 48” 5” CW G A V AC115V 30” 6” x 30” Fume Vent 5” 1-1/4” 31-1/4” 96” 72” 72” Wide Postless Sash Fume Hood 1-1/4” CW G A V 96” Wide Postless Sash Fume Hood 5-5/16” 6” x 23” Fume Vent CW G A V 5” 1-1/4” 30” 31-1/4” 120” 120” Wide Postless Sash Fume Hood 5” Technical 1-1/4” W 4” CW G A V AC115V 36” 5-5/16” 6” x 23” Fume Vent CW G A V 36” 5” 1-1/4” 31-1/4” 144” 144” Wide Postless Sash Fume Hood 148 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Dimensions – all radioisotope and perchloric acid fume hood: n Top of exhaust vent: Bench Fume Hood 88-1/4” (2242 mm) above finished floor with steel base. 87-3/4” (2229 mm) above finished floor with wood base. n Top of exhaust vent: Bench High-line Fume Hood 100-1/4” (2546 mm) above finished floor with steel base. 99-3/4” (2534 mm) above finished floor with wood base. n Duct connection must overlap vent by maximum of 1-1/4” (32 mm). (See page 125 for Duct Transition.) n Suggested roughing-in dimensions are from floor. Symbols: CW – Cold Water HW – Hot Water G – Gas A – Compressed Air V – Vacuum W – Waste AC – 115 or 230 Volt For Radioisotope Fume Hood 1-1/4” 5-5/16” CW G A 6” x 15” V Fume Vent CW G A AC 115V V 24” 5” 5” 1-1/4” 1-1/4” 31-1/4” 36” 31-1/4” 60” Wide Radioisotope Fume Hood 72” Wide Radioisotope Fume Hood 6” x 30” Fume Vent 48” 1-1/4” 72” 5-5/16” CW G A V AC 115V 1-1/4” 5-5/16” CW G A V 6” x 23” Fume Vent CW G A V AC 115V 60” 48” 5” 5” 5” 6” x 23” Fume Vent 30” 48” Wide Radioisotope Fume Hood 1-1/4” 5-5/16” CW G A V CW G A V AC 115V 5” 1-1/4” 31-1/4” 5” CW G A V 1-1/4” 31-1/4” 96” 96” Wide Radioisotope Fume Hood For Perchloric Acid Fume Hood 7-3/4” 7-3/4” 5” 1-1/4” W 4” CW G A AC115V V 5-5/16” W CW G A V 24” 6” x 15” Fume Vent 5” 5” 1-1/4” 1-1/4” W 5-5/16” CW G A V W 4” CW G A AC115V V 31-1/4” 5” 1-1/4” 6” x 23” Fume Vent 36” Technical 5” 31-1/4” 72” 48” 48” Wide Perchloric Acid Fume Hood 72” Wide Perchloric Acid Fume Hood For Pass Through/Demonstration Fume Hood 8” 5” 8-1/2” W 16-1/4” CW 6” x 15” Fume Vent 7-5/8” G 6-1/2” 32-1/2” 4” 7-5/8” 60” 60” Wide Pass-through/Demonstration Fume Hood 149 Thermo Scientific Hamilton Air Flow Products Dimensions – Advantage: n Top of exhaust vent: Advantage Fume Hood 95” (2413 mm) above finished floor with 36” (914 mm) high base cabinet. n Duct connection must overlap vent by maximum of 1-1/4” (32 mm). (See page 125 for Duct Transition.) n Rectangular to round transition included 2-5/8” 2-1/8” 5” 2-5/8” 2-1/8” 8-2/5” 5” 24” Plumbing Area (Typ Both Sides) Junction Box For Electrical Connection 33-1/2” 39-1/2” 33-1/2” 39-1/2” Ø 10.000 Junction Box For Electrical Connection Exhaust Outlet Ø Fixture information for Advantage Fume Hood: n Four fixtures per post maximum n Use 1/4” soft copper lines only – black iron and steam lines will not fit 2-5/8” 2-1/8” 8-2/5” 5” 30” 33-1/2” 39-1/2” 10.000 Exhaust Outlet 36” 9-2/5” Junction Box For Electrical Connection Ø 2-5/8” 42” 2-5/8” 2-1/8” 5” Ø 48” 2-1/8” 5” 9-2/5” Junction Box For Electrical Connection 12.000 Exhaust Outlet 72” 60” 48” 33-1/2” 39-1/2” Symbols: CW – Cold Water HW – Hot Water G – Gas A – Compressed Air V – Vacuum W – Waste AC – 115 or 230 Volt 9-2/5” 33-1/2” 39-1/2” 12.000 Exhaust Outlet Ø 84” 12.000 Exhaust Outlet 96” Horizon Fume Hood 22” 22” 3” 7.3” 5” Technical 3” x 2” Pipe Chase 28” 3” 3” 28” CL Plumbing Free 4” x 30” 32-5/16” Area at Floor Fume Vent Single Sided 22” 3” C L Plumbing Free 4” x 30” Area at Floor Fume Vent 3” x 2” Pipe Chase Single Sided 28” 3” 3” 64-19/32” C L 7.3” 7.3” 5” 5” 3” 3” x 2” Pipe Chase Plumbing Free Area at Floor 4” x 30” Fume Vent 32-5/16” Single Sided 34” 28” 64-19/32” C L 9” x 30” Plumbing Free C L Fume Vent 6” x 2” Area at Floor Pipe Chase Double Sided 34” 3” 3” 3” 60” C L 72” 7.3” C L Plumbing Free 9” x 30” Area at Floor Fume Vent 6” x 2” Double Sided Pipe Chase 150 32-5/16” 60” 22” 48” 34” 3” 7.3” 5” 7.3” 5” 48” 7.3” 5” 5” 34” 3” 7.3” 5” 5” 7.3” 64-19/32” C L 9” x 30” Plumbing Free C L Fume Vent 6” x 2” Area at Floor Pipe Chase Double Sided 72” www.thermo.com/hamilton Example of Specification for SafeAire and SafeAire II Part 1 – General 1.01 Fume Hood General Design Requirements A. Negative variations of face velocity shall not exceed 20% of the average face velocity. B. Average illumination of work area: Minimum 80 foot candles. C. Fume hood shall be designed to minimize static pressure loss with adequate slot area and rectangular exhaust collar configuration. Maximum static pressure loss readings shall not exceed the following maximum with sash in full open position: Measured S.P.L. (w.g.): .30 inches D. Maximum variation in exhaust CFM, static pressure and average face velocity as a result of baffle adjustment shall not exceed 5% for any baffle position. E. Noise Criteria: Test data of octave band analysis verifying fume hood is capable of a 50 NC value when connected to a 50 NC HVAC source. Reading taken 3' in front of open sash at 100 FPM face velocity. Submit test report. F. Fume Hood must be UL 1805 labeled. 1.02 Linear Surface Finish Performance Requirements (At specifier's option, insert applicable performance requirements for type C, E, R, P or S liners.) 1.03 Submittals A. Test reports: Submit test reports on each size and type of fume hood verifying conformance to test performance specified. 1.04 Quality Assurance A. Single source responsibility: Fume hood casework, work surfaces, and other laboratory equipment and accessories shall be manufactured or furnished by a single laboratory furniture company. 1. Five years or more experience in manufacture of laboratory fume hood and equipment of type specified. 2. UL 1805 labeled fume hood. Part 2 – Products 2.01 Manufacturer A. Casework and equipment manufacturer: Hamilton L.L.C., 1316 - 18th Street, Two Rivers, WI 54241 2.02 Fume Hood Materials A. Steel: High quality, cold rolled steel meeting requirements of ASTM A1008. B. Stainless Steel: Type 304. C. Ceiling enclosure panels: Minimum 18 gauge steel, upward directional louvers. D. Safety glass: 7/32” (6 mm) thick laminated safety glass. E. Sash cables: Stainless steel, uncoated, 1/8” diameter military spec. quality (MIL-DTL-83420). F. Sash guides: Corrosion-resistant poly-vinyl chloride. G. Pulley assembly for sash cable: 2” diameter, zinc dichromate finish, ball bearing type, with cable retaining device. (Nylon tire not acceptable.) H. Sash Pull: Full width corrosion-resistant, stainless steel or steel with chemical-resistant powdercoating. I. Gaskets: 70 durometer PVC for interior access panels. Gasket interior access panels to eliminate air leakage and to retain liquids inside fume hood. J. Fasteners: 1. Interior fastening devices concealed. Exposed screws not acceptable. 2. Exterior panel member fastening devices to be corrosion-resistant, non-metallic material. Exposed screws not acceptable. K. Interior Liners: The liner consists of all interior surfaces, including sides, back, top, and baffles. Not all liner materials are available for every fume hood model; refer to the product information page for options applicable to a specific fume hood. All liner materials have low flame ratings and meet NFPA-45 standards. Descriptions of each follow below: 1. White Polyresin ”P” – The preferred fume hood liner material, white polyresin is a press-molded, heatconverted catalyzed glass polyester sheet. A premium quality material, polyresin is excellent for use in high-abuse areas because of its excellent corrosion resistance. With a working temperature of 160°C, polyresin is flame-retardant and selfextinguishing. Scratches are less obvious because the white color extends throughout the material thickness. 2. Cement-based Board ”R” – The most economical fume hood liner material, cement-based board is a chemically resistant mixture of Portland cement and non-asbestos fibers formed under pressure into dense, light grey, 1/4” (6 mm) thick monolithic sheets. Low light reflectivity is a disadvantage. A reliable material under normal and light-duty use, cement-based board usually is specified when budgets are limited. 3. Cement-based Board with White Enamel Finish ”E” – cement-based board is covered and sealed with a chemical fume and splash-resistant enamel finish to provide a brighter, more comfortable working area. The enamel finish is also easier to clean. 4. Stainless Steel ”S” – All interior liner surfaces and baffles are fabricated of 16 gauge, Type 304 stainless steel with a number 4 finish. The liner top is spot-welded to the sides, and the dished work surface is attached and caulked to the sides and back. Rear vertical corners have a 1/2” (13 mm) radius for easy cleanup. 151 Specification Thermo Scientific Hamilton Air Flow Products Thermo Scientific Hamilton Air Flow Products 5. Stainless Steel ”K” – Standard without interior access panels, Type K interiors are suitable for radioisotope and perchloric acid fume hood. Made of 16 gauge Type 304 stainless steel with a number 4 finish, these interiors are welded, ground and polished to eliminate any seams or cracks where contaminants might collect. This fully coved, seamless interior simplifies cleanup and decontamination procedures. 6. PVC ”C” – White in color, 1/4” (6 mm) thick Type 1, Grade 1 with flame rating of less than 25. This liner is an excellent choice for highly corrosive applications. 2.03 Fume Hood Construction A. Superstructure: Rigid, self-supporting assembly of double wall construction, maximum 4-7/8” (124 mm) thick. Panels must be attached to a full frame construction, minimum 14 gauge galvanized members. Panels and brackets attached to eliminate screw heads and metallic bracketry from fume hood interior. B. Exhaust outlet: Rectangular with ends radiused. C. Access opening perimeter: Air foil or streamlined shape with all right angle corners radiused or angled. Bottom foil shall provide access areas for electrical cords. D. Fume hood sash: Full view type with clear, unobstructed, side-to-side view of fume hood interior and service fixture connections. 1. Counter balance system: Single weight, sprocket and chain, counter balance system which prevents sash tilting and permits ease of operation at any point along full width pull. Maximum 7 pounds pull required to raise or lower sash throughout its full 18” height of operating sash opening. Life cycle test sash and weight. Provide independent test data. Open and close sash against rubber bumper stops. E. Fume hood liner: Polyresin (designated by suffix ”P”). Reinforced polyester panel; smooth finish and white color in final appearance. Flexural strength: 14,000 psi. Flame spread: 25 or less per UL 723 and ASTM E84-80. F. Baffles: Provide exhaust slots full height on vertical sides of the baffle with upper and lower slots adjustable. All baffle supports/brackets to be non-metallic. G. Electrical Services: Three wire grounding type receptacles rated at 120 VAC at 20 amperes. H. Work surfaces: 1-1/4” (32 mm)thick surface, dished a nominal 1/2” (13 mm)to contain spills. Specification 2.04 Restricted Bypass Fume Hood A. Bypass shall be sufficient in size to allow 25% flow with sash closed. Bypass must be achieved through grill or louver on face of front lintel panel for SafeAire and SafeAire II and from top front of Concept. 2.05 Bypass Fume Hood A. Bypass shall be sufficient in size to allow sash as it is nearly closed (6”) to provide no more than four times increase in face velocity as measured when the sash was full open. 152 2.06 Metal Finish A. Preparation: Spray clean metal with a heated cleaner/phosphate solution, pretreat with iron phosphate spray, water rinse, and neutral final seal. B. Application: Electrostatically apply urethane powdercoat of selected color and bake in controlled high temperature oven. 1. Exterior and interior surfaces exposed to view: 1.5 mil., average and 1.2 mil., minimum coverage. 2.07 Source Quality Control Testing of Fume Hood A. Evaluation of manufacturer's standard product shall take place in manufacturer's own test facility, with testing personnel, samples, apparatus, instruments, and test materials supplied by the manufacturer at no cost to the Owner. B. Fume Hood shall achieve a rating of 4.0 AM 0.05 PPM or better when subjected to ASHRAE 110 1995 test procedures. 2.08 Field Quality Control Testing of Fume Hood A. Field testing requirements: 1. Perform tests after installation is complete, the building ventilation system has been balanced, all connections have been made, and written verification has been submitted that the above conditions have been met. B. Test procedure SEFA 2006. www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products 1.01 Scope A. The work of this section consists of fume hood workstations and related items. 1. Furnishing and installation of fume hood, including superstructure, fixtures, work top and base cabinet. 1.02 Submittals A. Shop Drawings: Submit complete shop drawings of all work on this section to architect for approval. B. Samples: Submit samples of all finish materials to the Architect for approval. 1. Sample of non-metallic glass retaining extrusion. C. Product Data: Submit complete manufacturer's product data covering each item of equipment to architect for approval. Proof of manufacturer of Fume Hood of similar design for a minimum of five years on five separate projects. Part 2 – Products 2.01 Type and Manufacturers A. Manufacturers: Subject to compliance with these minimum specified requirements, provide Fume Hood as manufactured by: 1. Thermo Fisher Scientific 1316 - 18th Street Two Rivers, WI 54241 B. Equipment Manufacturer: Only those manufacturers that equal this specification for design, construction and finish will be acceptable. Standard products are not necessarily considered equal unless meeting these minimum construction requirements. The owner's representative shall make the determination of equal products. The supplier shall be liable to meet these minimum requirements at no additional cost to the owner. C. UL 1805 labeled. 2.02 Fume Hood (Horizon) A. Construction of this shall provide a ventilated work area to protect operators from chemical fumes. B. Shall operate with sash open at 18” and provide upper body protection from sash viewing portion above 18” (457 mm) opening. C. Sash must automatically self-close to 18” (457 mm) position when left at any dimension above the 18” (457 mm) design working height, except when locked full open for setup. D. A manual non-exposed lock open feature shall be actuated from the front post to retain sash in full open setup position. E. Sash shall be glazed with 7/32” (6 mm) laminated safety glass. End panels shall be of 7/32” (6 mm) laminated safety glass. F. Center dividing panel between operators on either side of the fume hood shall be single panel 7/32” (6 mm) laminated safety glass. Multiple panels or baffles not acceptable. Lexan or similar plastic glazing not permitted. G. Lower 34” (864 mm) of fume hood above work surface must constitute a minimum of 75% clear glass glazing to maximize sight line. H. Shall be double sided (center bench) for operators to work on both sides (refer to drawings for layout), or single sided of like construction. I. Exhaust ventilation shall be provided at the work surface for heavy gases and in upper area for light gases. Vertical ventilation slots shall be provided on both sides of fume hood interior to purge sidewalls of fume hood and create a perimeter slot area. A single point rectangular exhaust connection at top of fume hood is required. J. Safety glass end panels and center divider panel shall be framed with PVC extrusions. K. Sash shall be counterbalanced with single weight attached with continuous military spec. grade stainless steel cable. Sash and counterbalance system to be life tested to 100,000 cycles with no sign of failure. L. Sash shall be retained in full-height sash track both sides of sash, with polyvinyl chloride extrusions. M. Provide top of bottom sill flush with top of work surface incorporating a trough for secondary containment of Shall be capable of achieving a 4.0 AM 0.05 rating when subjected to the ASHRAE 110 1995 tracer gas test performed with the sash at the 18” opening. O. Structure shall be of 18 gauge, 16 gauge, and 14 gauge cold rolled furniture steel, finished with acid and solventresistant urethane powdercoat finish. Visible screws or other fasteners shall not be permitted on fume hood interior or exterior. P. Service Fixtures and Fittings – Provision shall be made inside of fume hood to locate mechanical outlets off of work surface. Mechanical lines must not be exposed to contaminated fume hood or exhaust plenum areas. Remote control of services to be base cabinet located. Q. Work surfaces: 1-1/4” (32 mm) thick surface, dished a nominal one-half inch to contain spills. R. Fume Hood shipped knocked down, field assembly required. Specification Horizon Part 1 – General 153 Thermo Scientific Hamilton Air Flow Products Product Number Page Number ”B” SERIES NUMBERS BIO1310 . . . . . . . . . . . . . . . . . 86 BIO1311 . . . . . . . . . . . . . . . . . 86 BIO1345 . . . . . . . . . . . . . . . . . 85 BIO1347 . . . . . . . . . . . . . . . . . 85 BIO1355 . . . . . . . . . . . . . . . . . 85 BIO1357 . . . . . . . . . . . . . . . . . 85 BIO1360 . . . . . . . . . . . . . . . . . 86 BIO1361 . . . . . . . . . . . . . . . . . 86 BIO1375 . . . . . . . . . . . . . . . . . 85 BIO1377 . . . . . . . . . . . . . . . . . 85 BIO1385 . . . . . . . . . . . . . . . . . 85 BIO1387 . . . . . . . . . . . . . . . . . 85 ”C” SERIES NUMBERS 012C272 . . . . . . . . . . . . . . . . 108 013C272 . . . . . . . . . . . . . . . . 108 112C2720 . . . . . . . . . . . . . . . 108 113C2720 . . . . . . . . . . . . . . . 108 120C532 . . . . . . . . . . . . . . . . .107 120C572 . . . . . . . . . . . . . . . . 108 120C632 . . . . . . . . . . . . . . . . .107 120C672 . . . . . . . . . . . . . . . . 108 120C732 . . . . . . . . . . . . . . . . .107 120C772 . . . . . . . . . . . . . . . . 108 120C832 . . . . . . . . . . . . . . . . 107 120C872 . . . . . . . . . . . . . . . . 108 121C032 . . . . . . . . . . . . . . . . 107 121C072 . . . . . . . . . . . . . . . . 108 121C532 . . . . . . . . . . . . . . . . 107 121C572 . . . . . . . . . . . . . . . . 108 121C672 . . . . . . . . . . . . . . . . 108 121C772 . . . . . . . . . . . . . . . . 108 121C872 . . . . . . . . . . . . . . . . 108 121C632 . . . . . . . . . . . . . . . . 107 121C732 . . . . . . . . . . . . . . . . 107 121C832 . . . . . . . . . . . . . . . . 107 122C432 . . . . . . . . . . . . . . . . 107 123C032 . . . . . . . . . . . . . . . . 107 123C432 . . . . . . . . . . . . . . . . 107 123C072 . . . . . . . . . . . . . . . . 108 144C532 . . . . . . . . . . . . . . . . 107 144C632 . . . . . . . . . . . . . . . . 107 144C732 . . . . . . . . . . . . . . . . 107 144C832 . . . . . . . . . . . . . . . . 107 204C032C 204C032F 204C032R 204C232C 204C232F 204C232R 205C032C 205C032F 205C032R 205C232C 205C232F 205C232R . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 Product Number Page Number 554C403NR . . . . . . . . . . . . . . 71 554C403R . . . . . . . . . . . . . . . . 71 554C403RR . . . . . . . . . . . . . . . 71 554C404B . . . . . . . . . . . . . . . . 71 554C404BR . . . . . . . . . . . . . . 71 554C404L . . . . . . . . . . . . . . . . 71 554C404LR . . . . . . . . . . . . . . . 71 554C404N . . . . . . . . . . . . . . . . 71 554C404NR . . . . . . . . . . . . . . 71 554C404R . . . . . . . . . . . . . . . . 71 554C404RR . . . . . . . . . . . . . . . 71 554C405B . . . . . . . . . . . . . . . . 71 554C405BB . . . . . . . . . . . . . . 71 554C405BR . . . . . . . . . . . . . . 71 554C405L . . . . . . . . . . . . . . . . 71 554C405LB . . . . . . . . . . . . . . . 71 554C405LR . . . . . . . . . . . . . . . 71 554C405N . . . . . . . . . . . . . . . . 71 554C405NB . . . . . . . . . . . . . . 71 554C405NR . . . . . . . . . . . . . . 71 554C405R . . . . . . . . . . . . . . . . 71 554C405RB . . . . . . . . . . . . . . 71 554C405RR . . . . . . . . . . . . . . . 71 554C406B . . . . . . . . . . . . . . . . 71 554C406BB . . . . . . . . . . . . . . 71 554C406BR . . . . . . . . . . . . . . 71 554C406L . . . . . . . . . . . . . . . . 71 554C406LB . . . . . . . . . . . . . . . 71 554C406LR . . . . . . . . . . . . . . . 71 554C406N . . . . . . . . . . . . . . . . 71 554C406NB . . . . . . . . . . . . . . 71 554C406NR . . . . . . . . . . . . . . 71 554C406R . . . . . . . . . . . . . . . . 71 554C406RB . . . . . . . . . . . . . . 71 554C406RR . . . . . . . . . . . . . . . 71 554C409B . . . . . . . . . . . . . . . . 71 554C409BB . . . . . . . . . . . . . . 71 554C409BR . . . . . . . . . . . . . . 71 554C409L . . . . . . . . . . . . . . . . 71 554C409LB . . . . . . . . . . . . . . . 71 554C409LR . . . . . . . . . . . . . . . 71 554C409N . . . . . . . . . . . . . . . . 71 554C409NB . . . . . . . . . . . . . . 71 554C409NR . . . . . . . . . . . . . . 71 554C409R . . . . . . . . . . . . . . . . 71 554C409RB . . . . . . . . . . . . . . 71 554C409RR . . . . . . . . . . . . . . . 71 554C410B . . . . . . . . . . . . . . . . 71 554C410BB . . . . . . . . . . . . . . 71 554C410BR . . . . . . . . . . . . . . 71 554C410L . . . . . . . . . . . . . . . . 71 554C410LB . . . . . . . . . . . . . . . 71 554C410LR . . . . . . . . . . . . . . . 71 554C410N . . . . . . . . . . . . . . . . 71 554C410NB . . . . . . . . . . . . . . 71 554C410NR . . . . . . . . . . . . . . 71 554C410R . . . . . . . . . . . . . . . . 71 554C410RB . . . . . . . . . . . . . . 71 554C410RR . . . . . . . . . . . . . . . 71 554C325E . . . . . . . . . . . . . . . . 47 554C325P . . . . . . . . . . . . . . . . 47 611C7320 . . . . . . . . . . . . . . . 107 554C403B . . . . . . . . . . . . . . . . 71 554C403BR . . . . . . . . . . . . . . 71 554C403L . . . . . . . . . . . . . . . . 71 554C403LR . . . . . . . . . . . . . . . 71 554C403N . . . . . . . . . . . . . . . . 71 950C764D 950C765D 950C766D 950C767D 950C768D . . . . . . . . . . . . . . . 107 . . . . . . . . . . . . . . . 107 . . . . . . . . . . . . . . . 107 . . . . . . . . . . . . . . . 107 . . . . . . . . . . . . . . . 107 Product Number Page Number 950C769D . . . . . . . . . . . . . . . 107 ”L” SERIES NUMBERS 20L17100 . . . . . . . . . . . . . . . . 98 20L17200 . . . . . . . . . . . . . . . . 98 20L17300 . . . . . . . . . . . . . . . . 98 20L17400 . . . . . . . . . . . . . . . . 98 20L17500 . . . . . . . . . . . . . . . . 98 20L17800 . . . . . . . . . . . . . . . . 98 20L17900 . . . . . . . . . . . . . . . . 98 20L18000 20L18100 20L18200 20L18300 20L18400 20L18500 20L18600 20L18700 20L18800 20L18900 20L19000 20L19100 20L19200 20L19300 20L19400 20L19500 20L19600 20L19700 20L19800 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 20L24430 . . . . . . . . . . . . . . . . 79 20L258BB . . . . . . . . . . . . . . . 101 20L259BB . . . . . . . . . . . . . . . 101 20L260BB . . . . . . . . . . . . . . . 101 20L258BL . . . . . . . . . . . . . . . 101 20L259BL . . . . . . . . . . . . . . . 101 20L260BL . . . . . . . . . . . . . . . 101 20L258BN . . . . . . . . . . . . . . 101 20L259BN . . . . . . . . . . . . . . 101 20L260BN . . . . . . . . . . . . . . 101 20L258BR . . . . . . . . . . . . . . . 101 20L259BR . . . . . . . . . . . . . . . 101 20L260BR . . . . . . . . . . . . . . . 101 20L258WB . . . . . . . . . . . . . . 101 20L259WB . . . . . . . . . . . . . . 101 20L260WB . . . . . . . . . . . . . . 101 20L258WL . . . . . . . . . . . . . . 101 20L259WL . . . . . . . . . . . . . . 101 20L260WL . . . . . . . . . . . . . . 101 20L258WN . . . . . . . . . . . . . . 101 20L259WN . . . . . . . . . . . . . . 101 20L260WN . . . . . . . . . . . . . . 101 20L258WR . . . . . . . . . . . . . . 101 20L259WR . . . . . . . . . . . . . . 101 20L260WR . . . . . . . . . . . . . . 101 20L26500 . . . . . . . . . . . . . . . . 98 20L26600 . . . . . . . . . . . . . . . . 98 20L26700 . . . . . . . . . . . . . . . . 98 20L26800 . . . . . . . . . . . . . . . . 98 20L30500 . . . . . . . . . . . . . . . 101 20L30600 . . . . . . . . . . . . . . . 101 20L30700 . . . . . . . . . . . . . . . 101 20L30800 . . . . . . . . . . . . . . . 101 20L30900 . . . . . . . . . . . . . . . 101 21L3626000 . . . . . . . . . . . . . . 99 Product Number Page Number 21L36261LF . . . . . . . . . . . . . . 99 21L36261LFSS . . . . . . . . . . . 101 21L36261LR . . . . . . . . . . . . . . 99 21L36261RF . . . . . . . . . . . . . . 99 21L36261RR . . . . . . . . . . . . . 100 21L3631000 . . . . . . . . . . . . . . 99 21L36311LF . . . . . . . . . . . . . . 99 21L36311LR . . . . . . . . . . . . . . 99 21L36311RF . . . . . . . . . . . . . . 99 21L36311RR . . . . . . . . . . . . . 100 21L4826000 . . . . . . . . . . . . . . 99 21L4829000 . . . . . . . . . . . . . . 65 21L48261LF . . . . . . . . . . . . . . 99 21L48261LFSS . . . . . . . . . . . 101 21L48261LR . . . . . . . . . . . . . . 99 21L48261RF . . . . . . . . . . . . . . 99 21L48261RR . . . . . . . . . . . . . . 99 21L48290LF . . . . . . . . . . . . . . 65 21L48290LR . . . . . . . . . . . . . . 65 21L48290RF . . . . . . . . . . . . . . 65 21L48290RR . . . . . . . . . . . . . . 65 21L4830 . . . . . . . . . . . . . . . . 100 21L4831000 . . . . . . . . . . . . . . 99 21L48311LF . . . . . . . . . . . . . . 99 21L48311LR . . . . . . . . . . . . . . 99 21L48311RF . . . . . . . . . . . . . . 99 21L48311RR . . . . . . . . . . . . . 100 21L4832000 . . . . . . . . . . . . . . 99 21L48321LF . . . . . . . . . . . . . . 99 21L48321LR . . . . . . . . . . . . . . 99 21L48321RF . . . . . . . . . . . . . . 99 21L48321RR . . . . . . . . . . . . . 100 21L4835000 . . . . . . . . . . . . . . .65 21L4835100 . . . . . . . . . . . . . . .67 21L48350LF . . . . . . . . . . . . . . 65 21L48350LR . . . . . . . . . . . . . . 65 21L48350RF . . . . . . . . . . . . . . 65 21L48350RR . . . . . . . . . . . . . . 65 21L48351LF . . . . . . . . . . . . . . 67 21L48351RF . . . . . . . . . . . . . . 67 21L4838000 . . . . . . . . . . . . . . 99 21L48381LF . . . . . . . . . . . . . . 99 21L48381LR . . . . . . . . . . . . . . 99 21L48381RF . . . . . . . . . . . . . . 99 21L48381RR . . . . . . . . . . . . . 100 21L55000 21L55100 21L55200 21L55300 21L55400 21L55500 21L55600 21L55700 21L55800 21L55900 21L56000 21L56100 21L56200 21L56300 21L56400 21L56500 21L56600 21L56700 21L56800 21L56900 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . .98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 Product Number 21L57000 21L57100 21L57200 21L57300 21L57400 21L57500 21L57600 21L57700 21L57800 21L57900 21L58000 21L58100 21L58200 21L58300 21L58400 21L58500 21L58600 21L58700 21L58800 21L58900 21L59000 21L59100 21L59200 21L59300 21L59400 21L59500 21L59600 21L59700 21L59800 21L59900 Page Number . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 . . . . . . . . . . . . . . . . 98 21L60000 . . . . . . . . . . . . . . . . 98 21L60100 . . . . . . . . . . . . . . . . 98 21L60200 . . . . . . . . . . . . . . . . 98 21L6026000 . . . . . . . . . . . . . . 99 21L60261LF . . . . . . . . . . . . . . 99 21L60261LFSS . . . . . . . . . . . 101 21L60261LR . . . . . . . . . . . . . . 99 21L60261RF . . . . . . . . . . . . . . 99 21L60261RR . . . . . . . . . . . . . . 99 21L6029000 . . . . . . . . . . . . . . 65 21L60290LF . . . . . . . . . . . . . . 65 21L60290LR . . . . . . . . . . . . . . 65 21L60290RF . . . . . . . . . . . . . . 65 21L60300 . . . . . . . . . . . . . . . . 98 21L6031000 . . . . . . . . . . . . . . 99 21L6035000 . . . . . . . . . . . . . . 65 21L60350LF . . . . . . . . . . . . . . 65 21L60350LR . . . . . . . . . . . . . . 65 21L60350RF . . . . . . . . . . . . . . 65 21L60350RR . . . . . . . . . . . . . . 65 21L60311LF . . . . . . . . . . . . . . 99 21L60311LR . . . . . . . . . . . . . . 99 21L60311RF . . . . . . . . . . . . . . 99 21L60311RR . . . . . . . . . . . . . 100 21L6032000 . . . . . . . . . . . . . . 99 21L60321LF . . . . . . . . . . . . . . 99 21L60321LR . . . . . . . . . . . . . . 99 21L60321RF . . . . . . . . . . . . . . 99 21L60321RR . . . . . . . . . . . . . 100 21L6035100 . . . . . . . . . . . . . . .66 21L60351LF . . . . . . . . . . . . . . 67 21L60351RF . . . . . . . . . . . . . . 67 21L6038000 . . . . . . . . . . . . . . .99 21L60381LF . . . . . . . . . . . . . . 99 21L60381LR . . . . . . . . . . . . . . 99 21L60381RF . . . . . . . . . . . . . . 99 Dimension are nominal and illustrations and specifications are based on the latest product information available at the time of publication. The right is reserved to make changes at any time without notice. 154 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Product Number Page Number 21L60381RR . . . . . . . . . . . . . 100 21L60400 . . . . . . . . . . . . . . . . 98 21L60500 . . . . . . . . . . . . . . . . 98 21L60600 . . . . . . . . . . . . . . . . 98 21L60700 . . . . . . . . . . . . . . . . 98 21L60800 . . . . . . . . . . . . . . . . 98 21L60900 . . . . . . . . . . . . . . . . 98 21L61000 . . . . . . . . . . . . . . . . 98 21L61100 . . . . . . . . . . . . . . . . 98 21L61200 . . . . . . . . . . . . . . . . 98 21L61300 . . . . . . . . . . . . . . . . 98 21L61400 . . . . . . . . . . . . . . . . 98 21L61500 . . . . . . . . . . . . . . . . 98 21L61600 . . . . . . . . . . . . . . . . 98 21L61700 . . . . . . . . . . . . . . . . 98 21L7226000 . . . . . . . . . . . . . . 99 21L7229000 . . . . . . . . . . . . . . 65 21L72261LF . . . . . . . . . . . . . . 99 21L72261LFSS . . . . . . . . . . . 101 21L72261LR . . . . . . . . . . . . . . 99 21L72261RF . . . . . . . . . . . . . . 99 21L72261RR . . . . . . . . . . . . . 100 21L72290LF . . . . . . . . . . . . . . 65 21L72290LR . . . . . . . . . . . . . . 65 21L72290RF . . . . . . . . . . . . . . 65 21L72290RR . . . . . . . . . . . . . . 65 21L7230 . . . . . . . . . . . . . . . . 100 21L7231000 . . . . . . . . . . . . . . 99 21L72311LF . . . . . . . . . . . . . . 99 21L72311LR . . . . . . . . . . . . . . 99 21L72311RF . . . . . . . . . . . . . . 99 21L72311RR . . . . . . . . . . . . . 100 21L7232000 . . . . . . . . . . . . . . 99 21L72321LF . . . . . . . . . . . . . . 99 21L72321LR . . . . . . . . . . . . . . 99 21L72321RF . . . . . . . . . . . . . . 99 21L72321RR . . . . . . . . . . . . . 100 21L7235000 . . . . . . . . . . . . . . 65 21L72350LF . . . . . . . . . . . . . . 65 21L72350LR . . . . . . . . . . . . . . 65 21L72350RF . . . . . . . . . . . . . . 65 21L72350RR . . . . . . . . . . . . . . 65 21L7235100 . . . . . . . . . . . . . . 67 21L72351LF . . . . . . . . . . . . . . 67 21L72351RF . . . . . . . . . . . . . . 67 21L7238000 . . . . . . . . . . . . . . 99 21L72381LF . . . . . . . . . . . . . . 99 21L72381LR . . . . . . . . . . . . . . 99 21L72381RF . . . . . . . . . . . . . . 99 21L72381RR . . . . . . . . . . . . . 100 21L8426000 . . . . . . . . . . . . . . 99 21L8429000 . . . . . . . . . . . . . . 65 21L84261LF . . . . . . . . . . . . . . 99 21L84261LR . . . . . . . . . . . . . . 99 21L84261RF . . . . . . . . . . . . . . 93 21L84261RR . . . . . . . . . . . . . 100 21L84290LF . . . . . . . . . . . . . . 65 21L84290LR . . . . . . . . . . . . . . 65 21L84290RF . . . . . . . . . . . . . . 65 21L84290RR . . . . . . . . . . . . . . 65 21L8430 . . . . . . . . . . . . . . . . 100 21L8432000 . . . . . . . . . . . . . . 99 21L84321LF . . . . . . . . . . . . . . 99 21L84321LR . . . . . . . . . . . . . . 99 21L84321RF . . . . . . . . . . . . . . 99 Product Number Page Number 21L84321RR 21L8435000 21L84350LF 21L84350LR 21L84350RF 21L84350RR 21L8438000 21L84381LF 21L84381LR 21L84381RF 21L84381RR . . . . . . . . . . . . . 100 . . . . . . . . . . . . . . 65 . . . . . . . . . . . . . . 65 . . . . . . . . . . . . . . 65 . . . . . . . . . . . . . . 65 . . . . . . . . . . . . . . 65 . . . . . . . . . . . . . . 99 . . . . . . . . . . . . . . 99 . . . . . . . . . . . . . . 99 . . . . . . . . . . . . . . 99 . . . . . . . . . . . . . 100 21L9626000 . . . . . . . . . . . . . . 99 21L9629000 . . . . . . . . . . . . . . 65 21L96261LF . . . . . . . . . . . . . . 99 21L96261LFSS . . . . . . . . . . . 101 21L96261LR . . . . . . . . . . . . . . 99 21L96261RF . . . . . . . . . . . . . . 99 21L96261RR . . . . . . . . . . . . . . 99 21L96262BF . . . . . . . . . . . . . 100 21L96290BF . . . . . . . . . . . . . . 65 21L96290LF . . . . . . . . . . . . . . 65 21L96290LR . . . . . . . . . . . . . . 65 21L96290RF . . . . . . . . . . . . . . 65 21L96290RR . . . . . . . . . . . . . . 65 21L9630 . . . . . . . . . . . . . . . . 100 21L9631000 . . . . . . . . . . . . . . 99 21L96311LF . . . . . . . . . . . . . . 99 21L96311LR . . . . . . . . . . . . . . 99 21L96311RF . . . . . . . . . . . . . . 99 21L96311RR . . . . . . . . . . . . . . 99 21L96312BF . . . . . . . . . . . . . . 99 21L9632000 . . . . . . . . . . . . . . 99 21L96321LF . . . . . . . . . . . . . . 99 21L96321LR . . . . . . . . . . . . . . 99 21L96321RF . . . . . . . . . . . . . . 99 21L96321RR . . . . . . . . . . . . . 100 21L96322BF . . . . . . . . . . . . . 100 21L9635000 . . . . . . . . . . . . . . 65 21L9635100 . . . . . . . . . . . . . . 67 21L96350BF . . . . . . . . . . . . . . 65 21L96350LF . . . . . . . . . . . . . . 65 21L96350LR . . . . . . . . . . . . . . 65 21L96350RF . . . . . . . . . . . . . . 65 21L96350RR . . . . . . . . . . . . . . 65 21L96351LF . . . . . . . . . . . . . . 67 21L96351RF . . . . . . . . . . . . . . 67 21L96352LF . . . . . . . . . . . . . . 67 21L9638000 . . . . . . . . . . . . . . 99 21L96381LF . . . . . . . . . . . . . . 99 21L96381LR . . . . . . . . . . . . . . 99 21L96381RF . . . . . . . . . . . . . . 99 21L96381RR . . . . . . . . . . . . . 100 21L96382BF . . . . . . . . . . . . . 100 26L15000 26L15100 26L15200 26L15300 26L15800 26L15900 26L16000 . . . . . . . . . . . . . . . 122 . . . . . . . . . . . . . . . 122 . . . . . . . . . . . . . . . 122 . . . . . . . . . . . . . . . 122 . . . . . . . . . . . . . . . 122 . . . . . . . . . . . . . . . 122 . . . . . . . . . . . . . . . 122 27L161A0 27L161G0 27L161V0 27L16200 . . . . . . . . . . . . . . . . 95 . . . . . . . . . . . . . . . . 95 . . . . . . . . . . . . . . . . 95 . . . . . . . . . . . . . . . . 95 Product Number Page Number 27L16300 . . . . . . . . . . . . . . . . 95 28L02700 . . . . . . . . . . . . . . . . 95 28L151CW . . . . . . . . . . . . . . . 95 28L151HW . . . . . . . . . . . . . . . 95 28L152CW . . . . . . . . . . . . . . . 95 28L152HW . . . . . . . . . . . . . . . 95 30L496AW . . . . . . . . . . . . . . . 91 30L496GW . . . . . . . . . . . . . . . 91 30L496VW . . . . . . . . . . . . . . . 91 30L497AW . . . . . . . . . . . . . . . 91 30L497GW . . . . . . . . . . . . . . . 91 30L497VW . . . . . . . . . . . . . . . 91 30L499AW . . . . . . . . . . . . . . . 91 30L499GW . . . . . . . . . . . . . . . 91 30L499VW . . . . . . . . . . . . . . . 91 30L500AW . . . . . . . . . . . . . . . 91 30L500GW . . . . . . . . . . . . . . . 91 30L500VW . . . . . . . . . . . . . . . 91 30L567A0 . . . . . . . . . . . . . . . . 90 30L567G0 . . . . . . . . . . . . . . . . 90 30L567V0 . . . . . . . . . . . . . . . . 90 30L568A0 . . . . . . . . . . . . . . . . 90 30L568G0 . . . . . . . . . . . . . . . . 90 30L568V0 . . . . . . . . . . . . . . . . 90 30L569A0 . . . . . . . . . . . . . . . . 90 30L569G0 . . . . . . . . . . . . . . . . 90 30L569V0 . . . . . . . . . . . . . . . . 90 30L570A0 . . . . . . . . . . . . . . . . 90 30L570G0 . . . . . . . . . . . . . . . . 90 30L570V0 . . . . . . . . . . . . . . . . 90 30L571A0 . . . . . . . . . . . . . . . . 90 30L571G0 . . . . . . . . . . . . . . . . 90 30L571V0 . . . . . . . . . . . . . . . . 90 30L572A0 . . . . . . . . . . . . . . . . 90 30L572G0 . . . . . . . . . . . . . . . . 90 30L572V0 . . . . . . . . . . . . . . . . 90 30L57300 . . . . . . . . . . . . . . . . 91 30L57400 . . . . . . . . . . . . . . . . 91 30L57500 . . . . . . . . . . . . . . . . 91 30L57600 . . . . . . . . . . . . . . . . 91 30L57700 . . . . . . . . . . . . . . . . 91 30L57800 . . . . . . . . . . . . . . . . 91 30L57900 . . . . . . . . . . . . . . . . 91 30L58000 . . . . . . . . . . . . . . . . 91 30L589AW . . . . . . . . . . . . . . . 94 30L589GW . . . . . . . . . . . . . . . 94 30L589NW . . . . . . . . . . . . . . . 94 30L589OW . . . . . . . . . . . . . . . 94 30L589VW . . . . . . . . . . . . . . . 94 30L80000 30L80100 30L80200 30L80300 30L80500 30L80600 30L80700 30L80800 30L81000 30L81100 30L81200 30L81300 30L81500 30L81600 30L81700 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 Product Number Page Number 30L81800 30L82000 30L82100 30L82200 30L82300 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 . . . . . . . . . . . . . . . . 93 32L20000 32L00001 32L20200 32L20300 32L20400 32L20600 32L20700 32L24500 32L24600 32L24700 32L24800 32L24900 32L25000 32L25100 32L25200 32L25300 32L25400 32L25500 32L25600 32L26300 32L26400 32L26500 32L26600 32L26700 32L26800 32L26900 32L27000 32L27100 32L27400 32L27500 32L27600 32L27700 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 88 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 89 . . . . . . . . . . . . . . . . 95 Product Number Page Number . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 . . . . . . . . . . . . . . . 91 32L60500 . . . . . . . . . . . . . . . . 91 32L60600 . . . . . . . . . . . . . . . . 91 32L60700 . . . . . . . . . . . . . . . . 91 32L616CW . . . . . . . . . . . . . . . 92 32L617HO . . . . . . . . . . . . . . . . 90 32L617CO . . . . . . . . . . . . . . . . 90 32L618HO . . . . . . . . . . . . . . . . 90 32L618CO . . . . . . . . . . . . . . . . 90 32L619HO . . . . . . . . . . . . . . . . 90 32L619CO . . . . . . . . . . . . . . . . 90 32L620CO . . . . . . . . . . . . . . . . 90 32L620HO . . . . . . . . . . . . . . . . 90 32L622CO . . . . . . . . . . . . . . . . 90 32L621HO . . . . . . . . . . . . . . . . 90 32L621CO . . . . . . . . . . . . . . . . 90 32L622H0 . . . . . . . . . . . . . . . . 90 32L623C0 . . . . . . . . . . . . . . . . 90 32L623H0 . . . . . . . . . . . . . . . . 90 32L624C0 . . . . . . . . . . . . . . . . 90 32L624H0 . . . . . . . . . . . . . . . . 90 32L625C0 . . . . . . . . . . . . . . . . 90 32L625H0 . . . . . . . . . . . . . . . . 90 32L626C0 . . . . . . . . . . . . . . . . 90 32L626H0 . . . . . . . . . . . . . . . . 90 32L627H0 . . . . . . . . . . . . . . . . 90 32L627C0 . . . . . . . . . . . . . . . . 90 32L628H0 . . . . . . . . . . . . . . . . 90 32L628C0 . . . . . . . . . . . . . . . . 90 32L62900 . . . . . . . . . . . . . . . . 91 32L63000 . . . . . . . . . . . . . . . . 91 32L63100 . . . . . . . . . . . . . . . . 91 32L63200 . . . . . . . . . . . . . . . . 91 32L645CW . . . . . . . . . . . . . . . 94 32L645HW . . . . . . . . . . . . . . . 94 32L64600 . . . . . . . . . . . . . . . . 94 32L647CW . . . . . . . . . . . . . . . 94 32L647HW . . . . . . . . . . . . . . . 94 32L64800 . . . . . . . . . . . . . . . . 94 32L64900 . . . . . . . . . . . . . . . . 94 32L657CW . . . . . . . . . . . . . . . 92 32L663CW . . . . . . . . . . . . . . . 92 32L664CW . . . . . . . . . . . . . . . 92 32L665CW . . . . . . . . . . . . . . . 92 32L666CW . . . . . . . . . . . . . . . 92 32L66800 . . . . . . . . . . . . . . . . 92 32L66900 . . . . . . . . . . . . . . . . 92 32L67000 . . . . . . . . . . . . . . . . 92 32L67100 . . . . . . . . . . . . . . . . 92 32L67200 . . . . . . . . . . . . . . . . 92 32L675CW . . . . . . . . . . . . . . . 92 32L676CW . . . . . . . . . . . . . . . 92 32L677CW . . . . . . . . . . . . . . . 92 32L678CW . . . . . . . . . . . . . . . 92 32L688CW . . . . . . . . . . . . . . . 91 32L689CW . . . . . . . . . . . . . . . 91 32L690CW . . . . . . . . . . . . . . . 91 32L691CW . . . . . . . . . . . . . . . 91 32L692CW . . . . . . . . . . . . . . . 91 32L693CW . . . . . . . . . . . . . . . 91 32L694CW . . . . . . . . . . . . . . . 91 32L695CW . . . . . . . . . . . . . . . 91 32L715AW . . . . . . . . . . . . 65, 67 32L715CW . . . . . . . . . . . . 65, 67 32L715GW . . . . . . . . . . . . 65, 67 32L715VW . . . . . . . . . . . . 65, 67 32L60400 . . . . . . . . . . . . . . . . 91 32L80000 . . . . . . . . . . . . . . . . 93 CA32L552 . . . . . . . . . . . . . . . . 90 32L551CW 32L551HW 32L552CW 32L552HW 32L554CW 32L554HW 32L555CW 32L555HW 32L564WA 32L565WA 32L567WA 32L568WA 32L576DW 32L577DW 32L579DW 32L580DW 32L595CW 32L595HW 32L596CW 32L596HW 32L597CW 32L597HW 32L598CW 32L598HW 155 Thermo Scientific Hamilton Air Flow Products Product Number Page Number 32L80100 . . . . . . . . . . . . . . . . 93 32L80200 . . . . . . . . . . . . . . . . 93 32L80300 . . . . . . . . . . . . . . . . 93 32L80400 . . . . . . . . . . . . . . . . 93 32L80500 . . . . . . . . . . . . . . . . 93 32L80600 . . . . . . . . . . . . . . . . 93 32L80700 . . . . . . . . . . . . . . . . 93 32L80800 . . . . . . . . . . . . . . . . 93 32L80900 . . . . . . . . . . . . . . . . 93 32L81000 . . . . . . . . . . . . . . . . 93 32L81100 . . . . . . . . . . . . . . . . 93 32L81300 . . . . . . . . . . . . . . . . 93 32L81400 . . . . . . . . . . . . . . . . 93 32L81500 . . . . . . . . . . . . . . . . 93 32L81600 . . . . . . . . . . . . . . . . 93 32L81700 . . . . . . . . . . . . . . . . 93 32L81800 . . . . . . . . . . . . . . . . 93 32L81900 . . . . . . . . . . . . . . . . 93 32L82000 . . . . . . . . . . . . . . . . 93 32L82500 . . . . . . . . . . . . . . . . 93 32L82600 . . . . . . . . . . . . . . . . 93 32L82700 . . . . . . . . . . . . . . . . 93 32L82800 . . . . . . . . . . . . . . . . 93 32L82900 . . . . . . . . . . . . . . . . 93 32L83000 . . . . . . . . . . . . . . . . 93 32L83100 . . . . . . . . . . . . . . . . 93 32L83200 . . . . . . . . . . . . . . . . 93 32L841CW . . . . . . . . . . . . . . . 93 32L842CW . . . . . . . . . . . . . . . 93 32L843CW . . . . . . . . . . . . . . . 93 32L844CW . . . . . . . . . . . . . . . 93 32L84500 . . . . . . . . . . . . . . . . 93 32L84600 . . . . . . . . . . . . . . . . 93 32L84700 . . . . . . . . . . . . . . . . 93 32L84800 . . . . . . . . . . . . . . . . 93 32L84900 . . . . . . . . . . . . . . . . 93 32L85000 . . . . . . . . . . . . . . . . 93 32L85100 . . . . . . . . . . . . . . . . 93 32L85200 . . . . . . . . . . . . . . . . 93 32L91500 . . . . . . . . . . . . . . . . 93 32L91600 . . . . . . . . . . . . . . . . 93 32L91900 . . . . . . . . . . . . . . . . 93 32L92000 . . . . . . . . . . . . . . . . 93 32L925CW . . . . . . . . . . . . . . . 92 32L926CW . . . . . . . . . . . . . . . 92 34L13200 34L13700 34L19000 34L19100 34L19400 . . . . . . . . . . . . . . . 102 . . . . . . . . . . . . . . . 102 . . . . . . . . . . . . . . . 102 . . . . . . . . . . . . . . . 102 . . . . . . . . . . . . . . . 102 34L22400 34L22500 34L24500 34L25700 34L26900 34L27000 . . . . . . . . . . . . . . . 103 . . . . . . . . . . . . . . . 103 . . . . . . . . . . . . . . . 102 . . . . . . . . . . . . . . . 103 . . . . . . . . . . . . . . . 102 . . . . . . . . . . . . . . . 102 34L36100 . . . . . . . . . . . . . . . 102 36L09000 . . . . . . . . . . . . . . . 120 36L10900 36L109S0 36L11100 36L111S0 156 . . . . . . . . . . . . . . . 120 . . . . . . . . . . . . . . . 120 . . . . . . . . . . . . . . . 121 . . . . . . . . . . . . . . . 121 Product Number Page Number 36L11200 36L112H0 36L11600 36L12000 36L12100 36L120H0 36L121S0 36L12300 36L12600 36L12900 36L13100 36L131S0 36L13300 36L15100 36L19000 36L19100 36L19300 36L19400 36L19600 36L19800 36L19900 . . . . . . . . . . . . . . . 120 . . . . . . . . . . . . . . . 120 . . . . . . . . . . . . . . . 121 . . . . . . . . . . . . . . . 120 . . . . . . . . . . . . . . . 121 . . . . . . . . . . . . . . . 120 . . . . . . . . . . . . . . . 121 . . . . . . . . . . . . . . . 120 . . . . . . . . . . . . . . . 121 . . . . . . . . . . . . . . . 120 . . . . . . . . . . . . . . . 121 . . . . . . . . . . . . . . . 121 . . . . . . . . . . . . . . . 120 . . . . . . . . . . . . . . . 120 . . . . . . . . . . . . . . . 119 . . . . . . . . . . . . . . . 119 . . . . . . . . . . . . . . . 119 . . . . . . . . . . . . . . . 119 . . . . . . . . . . . . . . . 119 . . . . . . . . . . . . . . . 119 . . . . . . . . . . . . . . . 119 36L20000 36L20100 36L20200 36L20300 36L20400 36L20500 36L20600 36L20700 36L209S0 . . . . . . . . . . . . . . . 119 . . . . . . . . . . . . . . . 119 . . . . . . . . . . . . . . . 112 . . . . . . . . . . . . . . . 112 . . . . . . . . . . . . . . . 112 . . . . . . . . . . . . . . . 112 . . . . . . . . . . . . . . . .120 . . . . . . . . . . . . . . . .120 . . . . . . . . . . . . . . . 120 36L21100 36L211S0 36L21200 36L21300 . . . . . . . . . . . . . . . 121 . . . . . . . . . . . . . . . 121 . . . . . . . . . . . . . . . 120 . . . . . . . . . . . . . . . 120 36L24100 . . . . . . . . . . . . . . . 121 36L24200 . . . . . . . . . . . . . . . 121 36L24300 . . . . . . . . . . . . . . . 121 36L24400 . . . . . . . . . . . . . . . 121 36L26700 . . . . . . . . . . . . . . . 122 36L288SA . . . . . . . . . . . . . . . 122 36L288SO . . . . . . . . . . . . . . . 122 36L288WA . . . . . . . . . . . . . . 122 36L288WO . . . . . . . . . . . . . . 122 36L289SA . . . . . . . . . . . . . . . 122 36L289SO . . . . . . . . . . . . . . . 122 36L289WA . . . . . . . . . . . . . . 122 36L289WO . . . . . . . . . . . . . . 122 36L290SO . . . . . . . . . . . . . . . 122 36L290WO . . . . . . . . . . . . . . 122 54LAFA0500C4 54LAFA0500C5 54LAFA0500C6 54LAFA0500C7 54LAFA0500C8 54LAFA0500HC 54LAFA0500D0 54LAFA0500SC 54LAFA0500S1 54LAFA0500S3 54LAFA0500S4 54LAFA0500S5 54LAFA0500S6 54LAFA0500S8 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 Product Number 54LAFA1000C4 54LAFA1000C5 54LAFA1000C6 54LAFA1000C7 54LAFA1000C8 54LAFA1000H0 54LAFA1000HC 54LAFA1000D0 54LAFA1000SC 54LAFA1000S4 54LAFA1000S5 54LAFA1000S6 54LAFA1000S8 Page Number . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 . . . . . . . . . . . 96 54L0361231 . . . . . . . . . . . . . 110 54L0361731 . . . . . . . . . . . . . 110 54L0362431 . . . . . . . . . . . . . 110 54L0362931 . . . . . . . . . . . . . 110 54L0363631 . . . . . . . . . . . . . 110 54L04803 . . . . . . . . . . . . . . . 115 54L0481024 . . . . . . . . . . . . . 113 54L0481030 . . . . . . . . . . . . . 113 54L04811 . . . . . . . . . . . . . . . 115 54L0481231 . . . . . . . . . . . . . 110 54L04815 . . . . . . . . . . . . . . . 115 54L0481731 . . . . . . . . . . . . . 110 54L0482224 . . . . . . . . . . . . . 113 54L0482230 . . . . . . . . . . . . . 113 54L0482431 . . . . . . . . . . . . . 110 54L0482434 . . . . . . . . . . . . . 111 54L0482931 . . . . . . . . . . . . . 110 54L0482934 . . . . . . . . . . . . . 111 54L0483631 . . . . . . . . . . . . . 110 54L0483634 . . . . . . . . . . . . . 111 54L06003 . . . . . . . . . . . . . . . 115 54L0601024 . . . . . . . . . . . . . 113 54L0601030 . . . . . . . . . . . . . 113 54L06011 . . . . . . . . . . . . . . . 115 54L0601231 . . . . . . . . . . . . . 110 54L0601233 . . . . . . . . . . . . . 111 54L06015 . . . . . . . . . . . . . . . 115 54L0601731 . . . . . . . . . . . . . 110 54L0602224 . . . . . . . . . . . . . 113 54L0602230 . . . . . . . . . . . . . 113 54L0602431 . . . . . . . . . . . . . 110 54L0602433 . . . . . . . . . . . . . 111 54L0602434 . . . . . . . . . . . . . 111 54L0602931 . . . . . . . . . . . . . 110 54L0602934 . . . . . . . . . . . . . 111 54L0603631 . . . . . . . . . . . . . 110 54L0603633 . . . . . . . . . . . . . 111 54L0603634 . . . . . . . . . . . . . 111 54L07203 . . . . . . . . . . . . . . . 115 54L0721024 . . . . . . . . . . . . . 113 54L0721030 . . . . . . . . . . . . . 113 54L07211 . . . . . . . . . . . . . . . 115 54L0721231 . . . . . . . . . . . . . 110 54L07215 . . . . . . . . . . . . . . . 115 54L0721731 . . . . . . . . . . . . . 110 54L0722224 . . . . . . . . . . . . . 113 54L0722230 . . . . . . . . . . . . . 113 54L0722431 . . . . . . . . . . . . . 110 54L0722434 . . . . . . . . . . . . . 111 54L0722931 . . . . . . . . . . . . . 110 54L0722934 . . . . . . . . . . . . . 111 54L0723631 . . . . . . . . . . . . . 110 54L0723634 . . . . . . . . . . . . . 111 Product Number Page Number 54L08403 . . . . . . . . . . . . . . . 115 54L08411 . . . . . . . . . . . . . . . 115 54L08415 . . . . . . . . . . . . . . . 115 54L09603 . . . . . . . . . . . . . . . 115 54L09611 . . . . . . . . . . . . . . . 115 54L0961231 . . . . . . . . . . . . . 110 54L09615 . . . . . . . . . . . . . . . 115 54L0961731 . . . . . . . . . . . . . 110 54L0962431 . . . . . . . . . . . . . 110 54L0962434 . . . . . . . . . . . . . 111 54L0962931 . . . . . . . . . . . . . 110 54L0962934 . . . . . . . . . . . . . 111 54L0963631 . . . . . . . . . . . . . 110 54L0963634 . . . . . . . . . . . . . 111 54L1201231 . . . . . . . . . . . . . 113 54L1201731 . . . . . . . . . . . . . 113 54L1202431 . . . . . . . . . . . . . 113 54L1202931 . . . . . . . . . . . . . 113 54L1203631 . . . . . . . . . . . . . 113 54L1441231 . . . . . . . . . . . . . 113 54L1441731 . . . . . . . . . . . . . 113 54L1442431 . . . . . . . . . . . . . 113 54L1442931 . . . . . . . . . . . . . 113 54L1443631 . . . . . . . . . . . . . 113 54L17000 . . . . . . . . . . . . . . . . .82 54L17100 . . . . . . . . . . . . . . . . .82 54L17200 . . . . . . . . . . . . . . . . .82 54L17300 . . . . . . . . . . . . . . . . .82 54L17400 . . . . . . . . . . . . . . . . .82 54L17500 . . . . . . . . . . . . . . . . .82 54L17600 . . . . . . . . . . . . . . . . .82 54L17700 . . . . . . . . . . . . . . . . .82 54L17800 . . . . . . . . . . . . . . . . .82 54L17900 . . . . . . . . . . . . . . . . .82 54L18000 . . . . . . . . . . . . . . . . .82 54L18100 . . . . . . . . . . . . . . . . .82 54L18200 . . . . . . . . . . . . . . . . .82 54L21400 . . . . . . . . . . . . . . . 122 54L21600 . . . . . . . . . . . . . . . 122 54L22000 . . . . . . . . . . . . . . . 126 54L22200 . . . . . . . . . . . . . . . 126 54L22400 . . . . . . . . . . . . . . . 126 54L250T0 . . . . . . . . . . . . . . . . 64 54L251T0 . . . . . . . . . . . . . . . . 64 54L252T0 . . . . . . . . . . . . . . . . 64 54L253T0 . . . . . . . . . . . . . . . . 64 54L25400 . . . . . . . . . . . . . . . 125 54L254T0 . . . . . . . . . . . . . . . . 64 54L25600 . . . . . . . . . . . . . . . 121 54L2570P0 . . . . . . . . . . . . . . . 50 54L2571P0 . . . . . . . . . . . . . . . 50 54L2572P0 . . . . . . . . . . . . . . . 50 54L2573P0 . . . . . . . . . . . . . . . 50 54L2574P0 . . . . . . . . . . . . . . . 50 54L2586 . . . . . . . . . . . . . . . . . 23 54L2588 . . . . . . . . . . . . . . . . . 23 54L2589 . . . . . . . . . . . . . . . . . 23 54L2591 . . . . . . . . . . . . . . . . . 23 54L2592 . . . . . . . . . . . . . . . . . 23 54L2594 . . . . . . . . . . . . . . . . . 23 54L2595 . . . . . . . . . . . . . . . . . 23 54L2597 . . . . . . . . . . . . . . . . . 23 54L2598 . . . . . . . . . . . . . . . . . 23 54L2600 . . . . . . . . . . . . . . . . . 23 54L26100 . . . . . . . . . . . . . . . . 75 Product Number Page Number 54L26200 . . . . . . . . . . . . . . . . 75 54L2641PB . . . . . . . . . . . . . . . 52 54L2641PC . . . . . . . . . . . . . . . 52 54L2641P0 . . . . . . . . . . . . . . . 52 54L2641SB . . . . . . . . . . . . . . . 52 54L2641SC . . . . . . . . . . . . . . . 52 54L2641S0 . . . . . . . . . . . . . . . 52 54L2642PB . . . . . . . . . . . . . . . 52 54L2642PC . . . . . . . . . . . . . . . 52 54L2642P0 . . . . . . . . . . . . . . . 52 54L2642SB . . . . . . . . . . . . . . . 52 54L2642SC . . . . . . . . . . . . . . . 52 54L2642S0 . . . . . . . . . . . . . . . 52 54L2643PB . . . . . . . . . . . . . . . 52 54L2643PC . . . . . . . . . . . . . . . 52 54L2643P0 . . . . . . . . . . . . . . . 52 54L2643SB . . . . . . . . . . . . . . . 52 54L2643SC . . . . . . . . . . . . . . . 52 54L2643S0 . . . . . . . . . . . . . . . 52 54L2644PB . . . . . . . . . . . . . . . 52 54L2644PC . . . . . . . . . . . . . . . 52 54L2644P0 . . . . . . . . . . . . . . . 52 54L2644SB . . . . . . . . . . . . . . . 52 54L2644SC . . . . . . . . . . . . . . . 45 54L2644S0 . . . . . . . . . . . . . . . 45 54L2645PB . . . . . . . . . . . . . . . 52 54L2645PC . . . . . . . . . . . . . . . 52 54L2645P0 . . . . . . . . . . . . . . . 52 54L2645SB . . . . . . . . . . . . . . . 52 54L2645SC . . . . . . . . . . . . . . . 52 54L2645S0 . . . . . . . . . . . . . . . 52 54L2650P0 . . . . . . . . . . . . . . 52 54L2650S0 . . . . . . . . . . . . . . 52 54L2651P0 . . . . . . . . . . . . . . 52 54L2651S0 . . . . . . . . . . . . . . 52 54L2652P0 . . . . . . . . . . . . . . 52 54L2652S0 . . . . . . . . . . . . . . 52 54L2653P0 . . . . . . . . . . . . . . 52 54L2653S0 . . . . . . . . . . . . . . 52 54L2654P0 . . . . . . . . . . . . . . 52 54L2654S0 . . . . . . . . . . . . . . 52 54L2685 . . . . . . . . . . . . . . . . . 25 54L2687 . . . . . . . . . . . . . . . . . 25 54L2688 . . . . . . . . . . . . . . . . . 25 54L2690 . . . . . . . . . . . . . . . . . 25 54L2691 . . . . . . . . . . . . . . . . . 25 54L2693 . . . . . . . . . . . . . . . . . 25 54L2694 . . . . . . . . . . . . . . . . . 25 54L2696 . . . . . . . . . . . . . . . . . 25 54L2697 . . . . . . . . . . . . . . . . . 25 54L2699 . . . . . . . . . . . . . . . . . 25 54L2700 . . . . . . . . . . . . . . . . . 25 54L2702 . . . . . . . . . . . . . . . . . 25 54L2703 . . . . . . . . . . . . . . . . . 25 54L2705 . . . . . . . . . . . . . . . . . 25 54L2706 . . . . . . . . . . . . . . . . . 25 54L2708 . . . . . . . . . . . . . . . . . 25 54L27000 . . . . . . . . . . . . . . . . 76 54L27100 . . . . . . . . . . . . . . . . 76 54L27200 . . . . . . . . . . . . . . . . 75 54L27300 . . . . . . . . . . . . . . . . 75 54L2733K . . . . . . . . . . . . . . . . 29 54L2735K . . . . . . . . . . . . . . . . 29 54L2736K . . . . . . . . . . . . . . . . 29 54L2738K . . . . . . . . . . . . . . . . 29 54L2739K . . . . . . . . . . . . . . . . 29 54L27400 . . . . . . . . . . . . . . . . 75 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Product Number Page Number 54L2741K . . . . . . . . . . . . . . . . 29 54L2742K . . . . . . . . . . . . . . . . 29 54L2744K . . . . . . . . . . . . . . . . 29 54L2750P0 . . . . . . . . . . . . . . . 50 54L2750PB . . . . . . . . . . . . . . . 50 54L2751PB . . . . . . . . . . . . . . . 50 54L2751P0 . . . . . . . . . . . . . . . 50 54L2752P0 . . . . . . . . . . . . . . . 50 54L2752PB . . . . . . . . . . . . . . . 50 54L2753P0 . . . . . . . . . . . . . . . 50 54L2753PB . . . . . . . . . . . . . . . 50 54L2754P0 . . . . . . . . . . . . . . . 50 54L2754PB . . . . . . . . . . . . . . . 50 54L27600 . . . . . . . . . . . . . . . . 76 54L2766 . . . . . . . . . . . . . . . . . 19 54L2768 . . . . . . . . . . . . . . . . . 19 54L2769 . . . . . . . . . . . . . . . . . 19 54L27700 . . . . . . . . . . . . . . . . .76 54L2771 . . . . . . . . . . . . . . . . . 19 54L2772 . . . . . . . . . . . . . . . . . 19 54L2774 . . . . . . . . . . . . . . . . . 19 54L2775 . . . . . . . . . . . . . . . . . 19 54L2777 . . . . . . . . . . . . . . . . . 19 54L2778 . . . . . . . . . . . . . . . . . 19 54L2780 . . . . . . . . . . . . . . . . . 19 54L2793K . . . . . . . . . . . . . . . . 27 54L2797K . . . . . . . . . . . . . . . . 27 54L2801 . . . . . . . . . . . . . . . . . 21 54L2803 . . . . . . . . . . . . . . . . . 21 54L2804 . . . . . . . . . . . . . . . . . 21 54L2806 . . . . . . . . . . . . . . . . . 21 54L2807 . . . . . . . . . . . . . . . . . 21 54L2809 . . . . . . . . . . . . . . . . . 21 54L2810 . . . . . . . . . . . . . . . . . 21 54L2812 . . . . . . . . . . . . . . . . . 21 54L2813 . . . . . . . . . . . . . . . . . 21 54L2815 . . . . . . . . . . . . . . . . . 21 54L2816 . . . . . . . . . . . . . . . . . 21 54L2818 . . . . . . . . . . . . . . . . . 21 54L2819 . . . . . . . . . . . . . . . . . 21 54L2821 . . . . . . . . . . . . . . . . . 21 54L2822 . . . . . . . . . . . . . . . . . 21 54L2824 . . . . . . . . . . . . . . . . . 21 54L29600 . . . . . . . . . . . . . . . 125 54L29700 . . . . . . . . . . . . . . . 125 54L29800 . . . . . . . . . . . . . . . 125 54L29900 . . . . . . . . . . . . . . . 125 54L30000 . . . . . . . . . . . . . . . 125 54L31170LCEP . . . . . . . . . . . 116 54L31170RCEP . . . . . . . . . . 116 54L31200 . . . . . . . . . . . . . . . 121 54L31200LCEP . . . . . . . . . . . 116 54L31200RCEP . . . . . . . . . . 116 54L31280LCEP . . . . . . . . . . . 116 54L31280RCEP . . . . . . . . . . 116 54L31300 . . . . . . . . . . . . . . . 121 54L31320LCEP . . . . . . . . . . . 116 54L31320RCEP . . . . . . . . . . 116 54L31530FHEP . . . . . . . . . . . 115 54L31650FHEP . . . . . . . . . . . 115 54L33100 . . . . . . . . . . . . . . . 126 54L33300 . . . . . . . . . . . . . . . 126 54L33500 . . . . . . . . . . . . . . . 126 54L35170LCEP . . . . . . . . . . . 118 54L35170RCEP . . . . . . . . . . 118 54L35200LCEP . . . . . . . . . . . 118 Product Number Page Number 54L35200RCEP . . . . . . . . . . 118 54L35280LCEP . . . . . . . . . . . 118 54L35280RCEP . . . . . . . . . . 118 54L35320LCEP . . . . . . . . . . . 118 54L35320RCEP . . . . . . . . . . 118 54L37170LCEP . . . . . . . . . . . 116 54L37170RCEP . . . . . . . . . . 116 54L37200LCEP . . . . . . . . . . . 116 54L37200RCEP . . . . . . . . . . 116 54L37280LCEP . . . . . . . . . . . 116 54L37280RCEP . . . . . . . . . . 116 54L37320LCEP . . . . . . . . . . . 116 54L37320RCEP . . . . . . . . . . 116 54L37530FHEP . . . . . . . . . . . 115 54L37650FHEP . . . . . . . . . . . 115 54L38210 . . . . . . . . . . . . . . . . 59 54L38270 . . . . . . . . . . . . . . . . 59 54L38330 . . . . . . . . . . . . . . . . 59 54L411 . . . . . . . . . . . . . . . . . 124 54L41170LCEP . . . . . . . . . . . 118 54L41170RCEP . . . . . . . . . . 118 54L41200LCEP . . . . . . . . . . . 118 54L41200RCEP . . . . . . . . . . 118 54L412 . . . . . . . . . . . . . . . . . 124 54L41280LCEP . . . . . . . . . . . 118 54L41280RCEP . . . . . . . . . . 118 54L413 . . . . . . . . . . . . . . . . . 124 54L41320LCEP . . . . . . . . . . . 118 54L41320RCEP . . . . . . . . . . 118 54L414 . . . . . . . . . . . . . . . . . 124 54L415 . . . . . . . . . . . . . . . . . 124 54L416 . . . . . . . . . . . . . . . . . 124 54L43170LCEP . . . . . . . . . . . 116 54L43170RCEP . . . . . . . . . . 116 54L43200LCEP . . . . . . . . . . . 116 54L43200RCEP . . . . . . . . . . 116 54L43280LCEP . . . . . . . . . . . 116 54L43280RCEP . . . . . . . . . . 116 54L43320LCEP . . . . . . . . . . . 116 54L43320RCEP . . . . . . . . . . 116 54L43530FHEP . . . . . . . . . . . 115 54L43650FHEP . . . . . . . . . . . 115 54L47170LCEP . . . . . . . . . . . 118 54L47170RCEP . . . . . . . . . . 118 54L47200LCEP . . . . . . . . . . . 118 54L47200RCEP . . . . . . . . . . 118 54L47280LCEP . . . . . . . . . . . 118 54L47280RCEP . . . . . . . . . . 118 54L47320LCEP . . . . . . . . . . . 118 54L47320RCEP . . . . . . . . . . 118 54L48170FCSE . . . . . . . . . . . 115 54L48170UBCE . . . . . . 116, 118 54L48175FCSE . . . . . . . . . . . 117 54L48200FCSE . . . . . . . . . . . 115 54L48200UBCE . . . . . . 116, 118 54L48205FCSE . . . . . . . . . . . 117 54L48280FCSE . . . . . . . . . . . 115 54L48280UBCE . . . . . . 116, 118 54L48285FCSE . . . . . . . . . . . 117 54L48320FCSE . . . . . . . . . . . 115 54L48320UBCE . . . . . . 116, 118 54L48325FCSE . . . . . . . . . . . 117 54L48525LBEP . . . . . . . . . . . . 67 54L48530LBEP . . . . . . . . . . . 115 54L48600 . . . . . . . . . . . . . . . 123 54L4860K . . . . . . . . . . . . . . . 123 Product Number Page Number 54L4860S . . . . . . . . . . . . . . . 123 54L48600LBEP . . . . . . . . . . . . 65 54L48650LBEP . . . . . . . . . . . 115 54L48700 . . . . . . . . . . . . . . . 123 54L4870K . . . . . . . . . . . . . . . 123 54L4870S . . . . . . . . . . . . . . . 123 54L48800 . . . . . . . . . . . . . . . 123 54L4880K . . . . . . . . . . . . . . . 123 54L4880S . . . . . . . . . . . . . . . 123 54L48895LBEP . . . . . . . . . . . 118 54L48900 . . . . . . . . . . . . . . . 123 54L4890K . . . . . . . . . . . . . . . 123 54L4890S . . . . . . . . . . . . . . . 123 54L50210 54L50270 54L50330 54L51200 54L51300 54L54900 54L55000 . . . . . . . . . . . . . . . . 59 . . . . . . . . . . . . . . . . 59 . . . . . . . . . . . . . . . . 59 . . . . . . . . . . . . . . . . 74 . . . . . . . . . . . . . . . . 74 . . . . . . . . . . . . . . . 126 . . . . . . . . . . . . . . . 126 54L60170FCSE . . . . . . . . . . . 115 54L60170UBCE . . . . . . 116, 118 54L60175FCSE . . . . . . . . . . . 117 54L60200FCSE . . . . . . . . . . . 115 54L60200UBCE . . . . . . 116, 118 54L60205FCSE . . . . . . . . . . . 117 54L60280FCSE . . . . . . . . . . . 115 54L60280UBCE . . . . . . 116, 118 54L60285FCSE . . . . . . . . . . . 117 54L60320FCSE . . . . . . . . . . . 115 54L60320UBCE . . . . . . . . . . 116 54L60325FCSE . . . . . . . . . . . 117 54L60530LBEP . . . . . . . . . . . 115 54L60525LBEP . . . . . . . . . . . . 67 54L60650LBEP . . . . . . . . . . . 115 54L60600LBEP . . . . . . . . . . . . 65 54L60895LBEP . . . . . . . . . . . 118 54L62210 . . . . . . . . . . . . . . . . 59 54L62270 . . . . . . . . . . . . . . . . 59 54L62330 . . . . . . . . . . . . . . . . 59 54L625 . . . . . . . . . . . . . . . . . . 31 54L627 . . . . . . . . . . . . . . . . . . 31 54L628 . . . . . . . . . . . . . . . . . . 31 54L630 . . . . . . . . . . . . . . . . . . 31 54L631 . . . . . . . . . . . . . . . . . . 31 54L633 . . . . . . . . . . . . . . . . . . 31 54L634 . . . . . . . . . . . . . . . . . . 31 54L636 . . . . . . . . . . . . . . . . . . 31 54L709 . . . . . . . . . . . . . . . . . . 33 54L711 . . . . . . . . . . . . . . . . . . 33 54L712 . . . . . . . . . . . . . . . . . . 33 54L714 . . . . . . . . . . . . . . . . . . 33 54L715 . . . . . . . . . . . . . . . . . . 33 54L717 . . . . . . . . . . . . . . . . . . 33 54L718 . . . . . . . . . . . . . . . . . . 33 54L720 . . . . . . . . . . . . . . . . . . 33 54L721 . . . . . . . . . . . . . . . . . . 33 54L72170FCSE . . . . . . . . . . . 108 54L72170UBCE . . . . . . 116, 118 54L72175FCSE . . . . . . . . . . . 117 54L72200FCSE . . . . . . . . . . . 108 54L72200UBCE . . . . . . 116, 118 54L72205FCSE . . . . . . . . . . . 117 54L72280FCSE . . . . . . . . . . . 108 Product Number Page Number 54L72280UBCE . . . . . . 116, 118 54L72285FCSE . . . . . . . . . . . 117 54L723 . . . . . . . . . . . . . . . . . . 33 54L72320FCSE . . . . . . . . . . . 108 54L72320UBCE . . . . . . 116, 118 54L72325FCSE . . . . . . . . . . . 117 54L724 . . . . . . . . . . . . . . . . . . 33 54L72525LBEP . . . . . . . . . . . . 67 54L72530LBEP . . . . . . . . . . . 115 54L726 . . . . . . . . . . . . . . . . . . 33 54L72600LBEP . . . . . . . . . . . . 65 54L72650LBEP . . . . . . . . . . . 115 54L727 . . . . . . . . . . . . . . . . . . 33 54L72895LBEP . . . . . . . . . . . 118 54L729 . . . . . . . . . . . . . . . . . . 33 54L730 . . . . . . . . . . . . . . . . . . 33 54L732 . . . . . . . . . . . . . . . . . . 33 54L74210 . . . . . . . . . . . . . . . . 59 54L74270 . . . . . . . . . . . . . . . . 59 54L74330 . . . . . . . . . . . . . . . . 59 54L781P . . . . . . . . . . . . . . . . . 45 54L783P . . . . . . . . . . . . . . . . . 45 54L784P . . . . . . . . . . . . . . . . . 45 54L786P . . . . . . . . . . . . . . . . . 45 54L787P . . . . . . . . . . . . . . . . . 45 54L789P . . . . . . . . . . . . . . . . . 45 54L790P . . . . . . . . . . . . . . . . . 45 54L792P . . . . . . . . . . . . . . . . . 45 54L79900 . . . . . . . . . . . . . . . 145 54L825E0 . . . . . . . . . . . . . . . . 47 54L825P0 . . . . . . . . . . . . . . . . 47 54L84170FCSE . . . . . . . . . . . 115 54L84170UBCE . . . . . . 116, 118 54L84175FCSE . . . . . . . . . . . 117 54L84200FCSE . . . . . . . . . . . 115 54L84200UBCE . . . . . . 116, 118 54L84205FCSE . . . . . . . . . . . 117 54L84280FCSE . . . . . . . . . . . 115 54L84280UBCE . . . . . . 116, 118 54L84285FCSE . . . . . . . . . . . 117 54L84320FCSE . . . . . . . . . . . 115 54L84320UBCE . . . . . . 116, 118 54L84325FCSE . . . . . . . . . . . 117 54L84530LBEP . . . . . . . . . . . 115 54L84600LBEP . . . . . . . . . . . . 65 54L84650LBEP . . . . . . . . . . . 115 54L84895LBEP . . . . . . . . . . . 118 54L850B0 . . . . . . . . . . . . . . . . 71 54L850BR . . . . . . . . . . . . . . . . 71 54L850L0 . . . . . . . . . . . . . . . . 71 54L850LR . . . . . . . . . . . . . . . . 71 54L850N0 . . . . . . . . . . . . . . . . 71 54L850NR . . . . . . . . . . . . . . . . 71 54L850R0 . . . . . . . . . . . . . . . . 71 54L850RR . . . . . . . . . . . . . . . . 71 54L851B0 . . . . . . . . . . . . . . . . 71 54L851BB . . . . . . . . . . . . . . . . 71 54L851BR . . . . . . . . . . . . . . . . 71 54L851L0 . . . . . . . . . . . . . . . . 71 54L851LB . . . . . . . . . . . . . . . . 71 54L851LR . . . . . . . . . . . . . . . . 71 54L851N0 . . . . . . . . . . . . . . . . 71 54L851NB . . . . . . . . . . . . . . . 71 54L851NR . . . . . . . . . . . . . . . . 71 54L851R0 . . . . . . . . . . . . . . . . 71 54L851RB . . . . . . . . . . . . . . . . 71 Product Number Page Number 54L851RR 54L852B0 54L852BB 54L852BR 54L852L0 54L852LB 54L852LR 54L852N0 54L852NB 54L852NR 54L852R0 54L852RB 54L852RR 54L853B0 54L853BR 54L853L0 54L853LR 54L853N0 54L853NR 54L853R0 54L853RR 54L854B0 54L854BB 54L854BR 54L854L0 54L854LB 54L854LR 54L854N0 54L854NB 54L854NR 54L854R0 54L854RB 54L854RR 54L855B0 54L855BB 54L855BR 54L855L0 54L855LB 54L855LR 54L855N0 54L855NB 54L855NR 54L855R0 54L855RB 54L855RR 54L86210 54L86270 54L86330 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 71 . . . . . . . . . . . . . . . . 59 . . . . . . . . . . . . . . . . 59 . . . . . . . . . . . . . . . . 59 54L90100 54L90200 54L90300 54L90400 54L90500 54L90600 54L90700 54L90800 54L90900 54L91000 54L91100 54L91200 54L91300 54L91400 54L91500 54L91600 54L91700 54L91800 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 . . . . . . . . . . . . . . . 125 157 Thermo Scientific Hamilton Air Flow Products Product Number 54L96170FCSE 54L96170UBCE 54L96175FCSE 54L96200FCSE 54L96200UBCE 54L96205FCSE 54L96280FCSE 54L96280UBCE 54L96285FCSE 54L96320FCSE 54L96320UBCE 54L96325FCSE 54L96525LBEP 54L96530LBEP 54L96600LBEP 54L96650LBEP 54L96895LBEP 55L753 55L754 55L755 55L756 55L757 55L758 55L759 55L760 55L761 55L762 55L763 55L764 55L765 55L766 55L767 55L768 55L769 55L770 55L771 55L772 55L773 55L774 55L775 55L776 55L777 55L778 55L779 55L780 55L781 55L782 55L783 55L784 55L785 55L786 55L787 55L788 55L789 55L790 55L791 55L792 55L793 55L794 55L795 55L796 55L797 55L798 55L799 Page Number . . . . . . . . . . . 115 . . . . . . 116, 118 . . . . . . . . . . . 117 . . . . . . . . . . . 115 . . . . . . 116, 118 . . . . . . . . . . . 117 . . . . . . . . . . . 115 . . . . . . 116, 118 . . . . . . . . . . . 117 . . . . . . . . . . . 115 . . . . . . 116, 118 . . . . . . . . . . . 117 . . . . . . . . . . . . 67 . . . . . . . . . . . 115 . . . . . . . . . . . . 65 . . . . . . . . . . . 115 . . . . . . . . . . . 117 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . 124, 126, 132, 133, 136 . . . . . . 124, 132, 133, 136 . . . . . . 124, 132, 133, 136 . . . . . . 124, 132, 133, 136 . . . . . . 124, 132, 133, 136 . . . . . . 124, 132, 133, 136 . . . . . . 124, 132, 133, 136 . . . . . . 124, 126, 134, 137 . . . . . . 124, 126, 134, 137 . . . . . . 124, 126, 134, 137 . . . . . . 124, 126, 134, 137 . . . . . . . . . . 124, 134, 137 . . . . . . . . . 124, 134, 137 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . . . . . .138 . . . . . . . . . . . . . .135, 138 55L800 . . . . . . . . . . . . . . . . . .135 158 Product Number 55L801 55L802 55L803 55L804 55L805 55L806 55L807 55L808 55L809 55L810 55L811 55L812 55L813 55L814 Page Number . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . . . . .135, 138 . . . . . . . . . . 132, 133, 136 . . . . . . . . . . 132, 133, 136 . . . . . . 126, 132, 133, 136 . . . . . . 126, 132, 133, 136 . . . . . . 126, 132, 133, 136 . . . . . . 126, 132, 133, 136 56L250LB . . . . . . . . . . . . . . . . .65 56L250L0 . . . . . . . . . . . . . . . . .65 56L251LB . . . . . . . . . . . . . . . . .65 56L251L0 . . . . . . . . . . . . . . . . .65 56L252LB . . . . . . . . . . . . . . . . .65 56L252L0 . . . . . . . . . . . . . . . . .65 56L253LB . . . . . . . . . . . . . . . . .65 56L253L0 . . . . . . . . . . . . . . . . .65 56L254LB . . . . . . . . . . . . . . . . .65 56L254L0 . . . . . . . . . . . . . . . . .65 56L250TB . . . . . . . . . . . . . . . . .65 56L250TO . . . . . . . . . . . . . . . . .65 56L251TB . . . . . . . . . . . . . . . . .65 56L251TO . . . . . . . . . . . . . . . . .65 56L252TB . . . . . . . . . . . . . . . . .65 56L252TO . . . . . . . . . . . . . . . . .65 56L253TB . . . . . . . . . . . . . . . . .65 56L253TO . . . . . . . . . . . . . . . . .65 56L254TB . . . . . . . . . . . . . . . . .65 56L254TO . . . . . . . . . . . . . . . . .65 56L31LED . . . . . . . . . . . . . . . . .65 56L41LED . . . . . . . . . . . . . . . . .65 56LLH34D . . . . . . . . . . . . . . . . .65 56LLH40D . . . . . . . . . . . . . . . . .65 56LRH34D . . . . . . . . . . . . . . . .65 56LRH40D . . . . . . . . . . . . . . . .65 59L250LB 59L250L0 59L251LB 59L251L0 59L252LB 59L252L0 59L253LB 59L253L0 59L254LB 59L254L0 59L250TB 59L250TO 59L251TB 59L251T0 59L252TB 59L252T0 59L253TB 59L253T0 59L254TB 59L254T0 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 . . . . . . . . . . . . . . . . .65 59L350T0 59L351T0 59L352T0 59L354T0 . . . . . . . . . . . . . . . . .67 . . . . . . . . . . . . . . . . .67 . . . . . . . . . . . . . . . . .67 . . . . . . . . . . . . . . . . .67 Product Number Page Number 59LAC100 . . . . . . . . . . . . . . . . .67 59LGSW00 . . . . . . . . . . . . . . . .67 59LHE100 . . . . . . . . . . . . . . . . .67 59LLH40F . . . . . . . . . . . . . . . . .67 59LNE100 . . . . . . . . . . . . . . . . .67 59LPK400 . . . . . . . . . . . . . . . . .67 59LPK500 . . . . . . . . . . . . . . . . .67 59LPK600 . . . . . . . . . . . . . . . . .67 59LPK800 . . . . . . . . . . . . . . . . .67 59LRH40F . . . . . . . . . . . . . . . . .67 60L0361236 60L0361736 60L0362436 60L0362936 60L0363636 60L0481236 60L0481736 60L0482436 60L0482439 60L0482936 60L0482939 60L0483636 60L0483639 60L0601236 60L0601736 60L0602436 60L0602439 60L0602936 60L0602939 60L0603636 60L0603639 60L0721236 60L0721736 60L0722436 60L0722439 60L0722936 60L0722939 60L0723636 60L0723639 60L0961236 60L0961736 60L0962436 60L0962439 60L0962936 60L0962939 60L0963636 60L0963639 60L2586P 60L2588P 60L2589P 60L2591P 60L2592P 60L2594P 60L2595P 60L2597P 60L2598P 60L2600P 60L2685P 60L2687P 60L2688P 60L2690P 60L2691P 60L2693P 60L2694P 60L2696P . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 103 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . . . . 23 . . . . . . . . . . . . . . . . 23 . . . . . . . . . . . . . . . . 23 . . . . . . . . . . . . . . . . 23 . . . . . . . . . . . . . . . . 23 . . . . . . . . . . . . . . . . 23 . . . . . . . . . . . . . . . . 23 . . . . . . . . . . . . . . . . 23 . . . . . . . . . . . . . . . . 23 . . . . . . . . . . . . . . . . 23 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 Product Number Page Number 60L2697P 60L2699P 60L2700P 60L2702P 60L2703P 60L2705P 60L2706P 60L2708P 60L2766P 60L2768P 60L2769P 60L2771P 60L2772P 60L2774P 60L2775P 60L2777P 60L2778P 60L2780P 60L2801P 60L2803P 60L2804P 60L2806P 60L2807P 60L2809P 60L2810P 60L2812P 60L2813P 60L2815P 60L2816P 60L2818P 60L2819P 60L2821P 60L2822P 60L2824P . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 25 . . . . . . . . . . . . . . . . 19 . . . . . . . . . . . . . . . . 19 . . . . . . . . . . . . . . . . 19 . . . . . . . . . . . . . . . . 19 . . . . . . . . . . . . . . . . 19 . . . . . . . . . . . . . . . . 19 . . . . . . . . . . . . . . . . 19 . . . . . . . . . . . . . . . . 19 . . . . . . . . . . . . . . . . 19 . . . . . . . . . . . . . . . . 19 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 60L625P 60L627P 60L628P 60L630P 60L631P 60L633P 60L634P 60L636P . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 60L709P 60L711P 60L712P 60L714P 60L715P 60L717P 60L718P 60L720P 60L721P 60L723P 60L724P 60L726P 60L727P 60L729P 60L730P 60L732P . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 61L0361237 61L0361737 61L0362437 61L0362937 61L0363637 61L0481237 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 Product Number 61L0481737 61L0482437 61L0482440 61L0482937 61L0482940 61L0483637 61L0483640 61L0601237 61L0601737 61L0602437 61L0602440 61L0602937 61L0602940 61L0603637 61L0603640 61L0721237 61L0721737 61L0722437 61L0722440 61L0722937 61L0722940 61L0723637 61L0723640 61L0961237 61L0961737 61L0962437 61L0962440 61L0962937 61L0962940 61L0963637 61L0963640 Page Number . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 61L2570P0 . . . . . . . . . . . . . . . 50 61L2571P0 . . . . . . . . . . . . . . . 50 61L2572P0 . . . . . . . . . . . . . . . 50 61L2573P0 . . . . . . . . . . . . . . . 50 61L2574P0 . . . . . . . . . . . . . . . 50 61L2589P . . . . . . . . . . . . . . . . 23 61L2591P . . . . . . . . . . . . . . . . 23 61L2592P . . . . . . . . . . . . . . . . 23 61L2594P . . . . . . . . . . . . . . . . 23 61L2595P . . . . . . . . . . . . . . . . 23 61L2597P . . . . . . . . . . . . . . . . 23 61L2598P . . . . . . . . . . . . . . . . 23 61L2600P . . . . . . . . . . . . . . . . 23 61L2641PB . . . . . . . . . . . . . . . 52 61L2641PC . . . . . . . . . . . . . . . 52 61L2641P0 . . . . . . . . . . . . . . . 52 61L2641SB . . . . . . . . . . . . . . . 52 61L2641SC . . . . . . . . . . . . . . . 52 61L2641S0 . . . . . . . . . . . . . . . 52 61L2642PB . . . . . . . . . . . . . . . 52 61L2642PC . . . . . . . . . . . . . . . 52 61L2642P0 . . . . . . . . . . . . . . . 52 61L2642SB . . . . . . . . . . . . . . . 52 61L2642SC . . . . . . . . . . . . . . . 52 61L2642S0 . . . . . . . . . . . . . . . 52 61L2643PB . . . . . . . . . . . . . . . 52 61L2643PC . . . . . . . . . . . . . . . 52 61L2643P0 . . . . . . . . . . . . . . . 52 61L2643SB . . . . . . . . . . . . . . . 52 61L2643SC . . . . . . . . . . . . . . . 52 61L2643S0 . . . . . . . . . . . . . . . 52 61L2644PB . . . . . . . . . . . . . . . 52 61L2644PC . . . . . . . . . . . . . . . 52 61L2644P0 . . . . . . . . . . . . . . . 52 61L2644SB . . . . . . . . . . . . . . . 52 www.thermo.com/hamilton Index Thermo Scientific Hamilton Air Flow Products Product Number Page Number 61L2644SC . . . . . . . . . . . . . . . 52 61L2644S0 . . . . . . . . . . . . . . . 52 61L2645PB . . . . . . . . . . . . . . . 52 61L2645PC . . . . . . . . . . . . . . . 52 61L2645P0 . . . . . . . . . . . . . . . 52 61L2645SB . . . . . . . . . . . . . . . 52 61L2645SC . . . . . . . . . . . . . . . 52 61L2645S0 . . . . . . . . . . . . . . . 52 61L2650P0 . . . . . . . . . . . . . . 52 61L2650S0 . . . . . . . . . . . . . . 52 61L2651P0 . . . . . . . . . . . . . . 52 61L2651S0 . . . . . . . . . . . . . . 52 61L2652P0 . . . . . . . . . . . . . . 52 61L2652S0 . . . . . . . . . . . . . . 52 61L2653P0 . . . . . . . . . . . . . . 52 61L2653S0 . . . . . . . . . . . . . . 52 61L2654P0 . . . . . . . . . . . . . . 52 61L2654S0 . . . . . . . . . . . . . . 52 61L2655PB . . . . . . . . . . . . . . . 63 61L2655P0 . . . . . . . . . . . . . . . 62 61L2656PB . . . . . . . . . . . . . . . 63 61L2656P0 . . . . . . . . . . . . . . . 62 61L2657PB . . . . . . . . . . . . . . . 63 61L2657P0 . . . . . . . . . . . . . . . 62 61L2658PB . . . . . . . . . . . . . . . 63 61L2658P0 . . . . . . . . . . . . . . . 62 61L2659PB . . . . . . . . . . . . . . . 63 61L2659P0 . . . . . . . . . . . . . . . 62 61L2685P . . . . . . . . . . . . . . . . 25 61L2687P . . . . . . . . . . . . . . . . 25 61L2688P . . . . . . . . . . . . . . . . 25 61L2690P . . . . . . . . . . . . . . . . 25 61L2691P . . . . . . . . . . . . . . . . 25 61L2693P . . . . . . . . . . . . . . . . 25 61L2694P . . . . . . . . . . . . . . . . 25 61L2696P . . . . . . . . . . . . . . . . 25 61L2697P . . . . . . . . . . . . . . . . 25 61L2699P . . . . . . . . . . . . . . . . 25 61L2700P . . . . . . . . . . . . . . . . 25 61L2702P . . . . . . . . . . . . . . . . 25 61L2703P . . . . . . . . . . . . . . . . 25 61L2705P . . . . . . . . . . . . . . . . 25 61L2706P . . . . . . . . . . . . . . . . 25 61L2708P . . . . . . . . . . . . . . . . 25 61L2750P0 . . . . . . . . . . . . . . . 50 61L2750PB . . . . . . . . . . . . . . . 50 61L2751P0 . . . . . . . . . . . . . . . 50 61L2751PB . . . . . . . . . . . . . . . 50 61L2752P0 . . . . . . . . . . . . . . . 50 61L2752PB . . . . . . . . . . . . . . . 50 61L2753P0 . . . . . . . . . . . . . . . 50 61L2753PB . . . . . . . . . . . . . . . 50 61L2754P0 . . . . . . . . . . . . . . . 50 61L2756PB . . . . . . . . . . . . . . . 50 61L2755PB . . . . . . . . . . . . . . . 60 61L2756PB . . . . . . . . . . . . . . . 60 61L2757PB . . . . . . . . . . . . . . . 60 61L2758PB . . . . . . . . . . . . . . . 60 61L2759PB . . . . . . . . . . . . . . . 60 61L2769P . . . . . . . . . . . . . . . . 19 61L2771P . . . . . . . . . . . . . . . . 19 61L2772P . . . . . . . . . . . . . . . . 19 61L2774P . . . . . . . . . . . . . . . . 19 61L2775P . . . . . . . . . . . . . . . . 19 61L2777P . . . . . . . . . . . . . . . . 19 61L2778P . . . . . . . . . . . . . . . . 19 61L2780P . . . . . . . . . . . . . . . . 19 Product Number 61L2801P 61L2803P 61L2804P 61L2806P 61L2807P 61L2809P 61L2810P 61L2812P 61L2813P 61L2815P 61L2816P 61L2818P 61L2819P 61L2821P 61L2822P 61L2824P Page Number . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . 21 61L625P 61L627P 61L628P 61L630P 61L631P 61L633P 61L634P 61L636P . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . .31 . . . . . . . . . . . . . . . . . 31 61L709P 61L711P 61L712P 61L714P 61L715P 61L717P 61L718P 61L720P 61L721P 61L723P 61L724P 61L726P 61L727P 61L729P 61L730P 61L732P . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 29 . . . . . . . . . . . . . . . . . 29 . . . . . . . . . . . . . . . . . 29 . . . . . . . . . . . . . . . . . 29 . . . . . . . . . . . . . . . . . 29 . . . . . . . . . . . . . . . . . 29 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 62L0361243 62L0361743 62L0362443 62L0362943 62L0363643 62L0481243 62L0481743 62L0482443 62L0482446 62L0482943 62L0482946 62L0483643 62L0483646 62L0601243 62L0601743 62L0602443 62L0602446 62L0602943 62L0602946 62L0603643 62L0603646 62L0721243 62L0721743 62L0722443 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 Product Number 62L0722446 62L0722943 62L0722946 62L0723643 62L0723646 62L0961243 62L0961743 62L0962443 62L0962446 62L0962943 62L0962946 62L0963643 62L0963646 Page Number . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 . . . . . . . . . . . . . 110 . . . . . . . . . . . . . 111 62L2570P0 . . . . . . . . . . . . . . . 50 62L2571P0 . . . . . . . . . . . . . . . 50 62L2572P0 . . . . . . . . . . . . . . . 50 62L2573P0 . . . . . . . . . . . . . . . 50 62L2574P0 . . . . . . . . . . . . . . . 50 62L2589P . . . . . . . . . . . . . . . . 23 62L2591P . . . . . . . . . . . . . . . . 23 62L2592P . . . . . . . . . . . . . . . . 23 62L2594P . . . . . . . . . . . . . . . . 23 62L2595P . . . . . . . . . . . . . . . . 23 62L2597P . . . . . . . . . . . . . . . . 23 62L2598P . . . . . . . . . . . . . . . . 23 62L2600P . . . . . . . . . . . . . . . . 23 62L2641PB . . . . . . . . . . . . . . . 52 62L2641PC . . . . . . . . . . . . . . . 52 62L2641P0 . . . . . . . . . . . . . . . 52 62L2641SB . . . . . . . . . . . . . . . 52 62L2641SC . . . . . . . . . . . . . . . 52 62L2641S0 . . . . . . . . . . . . . . . 52 62L2642PB . . . . . . . . . . . . . . . 52 62L2642PC . . . . . . . . . . . . . . . 52 62L2642P0 . . . . . . . . . . . . . . . 52 62L2642SB . . . . . . . . . . . . . . . 52 62L2642SC . . . . . . . . . . . . . . . 52 62L2642S0 . . . . . . . . . . . . . . . 52 62L2643PB . . . . . . . . . . . . . . . 52 62L2643PC . . . . . . . . . . . . . . . 52 62L2643P0 . . . . . . . . . . . . . . . 52 62L2643SB . . . . . . . . . . . . . . . 52 62L2643SC . . . . . . . . . . . . . . . 52 62L2643S0 . . . . . . . . . . . . . . . 52 62L2644PB . . . . . . . . . . . . . . . 52 62L2644PC . . . . . . . . . . . . . . . 52 62L2644P0 . . . . . . . . . . . . . . . 52 62L2644SB . . . . . . . . . . . . . . . 52 62L2644SC . . . . . . . . . . . . . . . 52 62L2644S0 . . . . . . . . . . . . . . . 52 62L2645PB . . . . . . . . . . . . . . . 52 62L2645PC . . . . . . . . . . . . . . . 52 62L2645P0 . . . . . . . . . . . . . . . 52 62L2645SB . . . . . . . . . . . . . . . 52 62L2645SC . . . . . . . . . . . . . . . 52 62L2645S0 . . . . . . . . . . . . . . . 52 62L2650P0 . . . . . . . . . . . . . . 52 62L2650S0 . . . . . . . . . . . . . . 52 62L2651P0 . . . . . . . . . . . . . . 52 62L2651S0 . . . . . . . . . . . . . . 52 62L2652P0 . . . . . . . . . . . . . . 52 62L2652S0 . . . . . . . . . . . . . . 52 62L2653P0 . . . . . . . . . . . . . . 52 62L2653S0 . . . . . . . . . . . . . . 52 62L2654P0 . . . . . . . . . . . . . . 52 62L2654S0 . . . . . . . . . . . . . . 52 Product Number Page Number 62L2685P . . . . . . . . . . . . . . . . 25 62L2687P . . . . . . . . . . . . . . . . 25 62L2688P . . . . . . . . . . . . . . . . 25 62L2690P . . . . . . . . . . . . . . . . 25 62L2691P . . . . . . . . . . . . . . . . 25 62L2693P . . . . . . . . . . . . . . . . 25 62L2694P . . . . . . . . . . . . . . . . 25 62L2696P . . . . . . . . . . . . . . . . 25 62L2697P . . . . . . . . . . . . . . . . 25 62L2699P . . . . . . . . . . . . . . . . 25 62L2700P . . . . . . . . . . . . . . . . 25 62L2702P . . . . . . . . . . . . . . . . 25 62L2703P . . . . . . . . . . . . . . . . 25 62L2705P . . . . . . . . . . . . . . . . 25 62L2706P . . . . . . . . . . . . . . . . 25 62L2708P . . . . . . . . . . . . . . . . 25 62L2750P0 . . . . . . . . . . . . . . . 50 62L2750PB . . . . . . . . . . . . . . . 50 62L2751P0 . . . . . . . . . . . . . . . 50 62L2751PB . . . . . . . . . . . . . . . 50 62L2752P0 . . . . . . . . . . . . . . . 50 62L2752PB . . . . . . . . . . . . . . . 50 62L2753P0 . . . . . . . . . . . . . . . 50 62L2753PB . . . . . . . . . . . . . . . 50 62L2754P0 . . . . . . . . . . . . . . . 50 62L2754PB . . . . . . . . . . . . . . . 50 62L2769P . . . . . . . . . . . . . . . . 19 62L2771P . . . . . . . . . . . . . . . . 19 62L2772P . . . . . . . . . . . . . . . . 19 62L2774P . . . . . . . . . . . . . . . . 19 62L2775P . . . . . . . . . . . . . . . . 19 62L2777P . . . . . . . . . . . . . . . . 19 62L2778P . . . . . . . . . . . . . . . . 19 62L2780P . . . . . . . . . . . . . . . . 19 62L2801P . . . . . . . . . . . . . . . . 21 62L2803P . . . . . . . . . . . . . . . . 21 62L2804P . . . . . . . . . . . . . . . . 21 62L2806P . . . . . . . . . . . . . . . . 21 62L2807P . . . . . . . . . . . . . . . . 21 62L2809P . . . . . . . . . . . . . . . . 21 62L2810P . . . . . . . . . . . . . . . . 21 62L2812P . . . . . . . . . . . . . . . . 21 62L2813P . . . . . . . . . . . . . . . . 21 62L2815P . . . . . . . . . . . . . . . . 21 62L2816P . . . . . . . . . . . . . . . . 21 62L2818P . . . . . . . . . . . . . . . . 21 62L2819P . . . . . . . . . . . . . . . . 21 62L2821P . . . . . . . . . . . . . . . . 21 62L2822P . . . . . . . . . . . . . . . . 21 62L2824P . . . . . . . . . . . . . . . . 21 62L625P 62L627P 62L628P 62L630P 62L631P 62L633P 62L634P 62L636P . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 . . . . . . . . . . . . . . . . . 31 62L709P 62L711P 62L712P 62L714P 62L715P 62L717P 62L718P . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 33 Product Number Page Number 62L720P . . . . . . . . . . . . . . . . . 33 62L721P . . . . . . . . . . . . . . . . . 33 62L723P . . . . . . . . . . . . . . . . . 33 62L724P . . . . . . . . . . . . . . . . . 33 62L726P . . . . . . . . . . . . . . . . . 33 62L727P . . . . . . . . . . . . . . . . . 33 62L729P . . . . . . . . . . . . . . . . . 33 62L730P . . . . . . . . . . . . . . . . . 33 62L732P . . . . . . . . . . . . . . . . . 33 90L06000 . . . . . . . . . . . . . . . 105 90L06300 . . . . . . . . . . . . . . . 105 90L06600 . . . . . . . . . . . . . . . 107 90L07600 . . . . . . . . . . . . . . . 123 90L07700 . . . . . . . . . . . . . . . 123 90L07800 . . . . . . . . . . . . . . . 105 90L07900 . . . . . . . . . . . . . . . 105 90L095N0 . . . . . . . . . . . . . . . 123 90L096N0 . . . . . . . . . . . . . . . 123 90L097N0 . . . . . . . . . . . . . . . 123 90L098N0 . . . . . . . . . . . . . . . 123 90L10000 90L10100 90L130N0 90L131N0 90L132N0 90L133N0 90L134N0 90L135N0 90L136N0 90L137N0 90L138N0 90L139N0 90L140N0 90L141N0 90L14131 90L14132 90L142N0 90L143N0 90L144N0 90L145N0 90L146N0 90L147N0 90L148N0 90L149N0 90L15000 90L150N0 90L15100 90L151N0 90L15200 90L152N0 90L15300 90L153N0 90L15400 90L154N0 90L15500 90L155N0 90L15600 90L156N0 90L15700 90L157N0 90L15800 90L158N0 90L15900 90L159N0 90L16000 90L160N0 . . . . . . . . . . . . . . . 116 . . . . . . . . . . . . . . . 116 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 159 Thermo Scientific Hamilton Air Flow Products Product Number Page Number 90L16100 90L161N0 90L18900 90L19000 90L19161 90L19162 90L19200 90L19300 90L19400 90L19500 90L19600 90L19700 90L19800 90L19900 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 114 . . . . . . . . . . . . . . . 107 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 113 . . . . . . . . . . . . . . . 113 . . . . . . . . . . . . . . . 113 . . . . . . . . . . . . . . . 113 . . . . . . . . . . . . . . . 113 . . . . . . . . . . . . . . . 113 . . . . . . . . . . . . . . . 113 . . . . . . . . . . . . . . . 113 90L20000 90L20100 90L20200 90L20300 90L20400 90L21191 90L21192 90L21200 90L21300 90L21400 90L21500 90L21600 90L21700 90L21800 90L21900 90L22000 90L22100 90L22200 90L22300 90L22400 90L22500 90L22600 90L22700 90L22800 90L23191 90L23192 90L25161 90L25162 90L25251 90L25252 90L27191 90L27192 90L29161 90L29162 90L29191 90L29192 . . . . . . . . . . . . . . . 113 . . . . . . . . . . . . . . . 113 . . . . . . . . . . . . . . . 113 . . . . . . . . . . . . . . . 113 . . . . . . . . . . . . . . . 113 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . . 77 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 90L31161 90L31162 90L33191 90L33192 90L35191 90L35192 90L37141 90L37142 90L37161 90L37162 90L39191 90L39192 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 90L41191 . . . . . . . . . . . . . . . 109 90L41192 . . . . . . . . . . . . . . . 109 160 Product Number 90L43161 90L43162 90L45191 90L45192 90L47191 90L47192 Page Number . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 . . . . . . . . . . . . . . . 109 90L57191 . . . . . . . . . . . . . . . 109 90L57192 . . . . . . . . . . . . . . . 109 ”P” SERIES NUMBERS 148P732GY . . . . . . . . . . . . . . . 79 950P200GY . . . . . . . . . . . . . . . 79 950P201GY . . . . . . . . . . . . . . . 79 950P2020 . . . . . . . . . . . . . . . . 79 950P2030 . . . . . . . . . . . . . . . . 79 950P2040 . . . . . . . . . . . . . . . . 79 950P2050 . . . . . . . . . . . . . . . . 79 ”S” SERIES NUMBERS 121S5320 . . . . . . . . . . . . . . . 105 121S5720 . . . . . . . . . . . . . . . .108 121S6320 . . . . . . . . . . . . . . . 105 121S6720 . . . . . . . . . . . . . . . .108 121S7320 . . . . . . . . . . . . . . . 105 121S7720 . . . . . . . . . . . . . . . .108 121S8320 . . . . . . . . . . . . . . . 105 121S8720 . . . . . . . . . . . . . . . .108 122S0320 . . . . . . . . . . . . . . . 105 122S0720 . . . . . . . . . . . . . . . .108 122S4720 . . . . . . . . . . . . . . . .108 123S0320 . . . . . . . . . . . . . . . 105 123S0720 . . . . . . . . . . . . . . . .108 123S4720 . . . . . . . . . . . . . . . .108 144S5320 . . . . . . . . . . . . . . . 105 144S6320 . . . . . . . . . . . . . . . 105 144S7320 . . . . . . . . . . . . . . . 105 144S8320 . . . . . . . . . . . . . . . .105 551S0482438 551S0482441 551S0482938 551S0482941 551S0483638 551S0483641 551S0602438 551S0602441 551S0602938 551S0602941 551S0603638 551S0603641 551S0722438 551S0722441 551S0722938 551S0722941 551S0723638 551S0723641 551S0962438 551S0962441 551S0962938 551S0962941 551S0963638 551S0963641 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 551S2741P0 551S2741S0 551S2742P0 551S2742S0 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 Product Number Page Number 551S2743P0 551S2743S0 551S2744P0 551S2744S0 551S2745P0 551S2745S0 551S2746P0 551S2746S0 551S2747P0 551S2747S0 551S2748P0 551S2748S0 551S2749P0 551S2749S0 551S2750P0 551S2750S0 551S2751PB 551S2751SB 551S2752PB 551S2752SB 551S2753PB 551S2753SB 551S2754PB 551S2754SB 551S2755PB 551S2755SB 551S2760PC 551S2760SC 551S2761PC 551S2761SC 551S2762PC 551S2762SC . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 551S326P . . . . . . . . . . . . . . . . 35 551S328P . . . . . . . . . . . . . . . . 35 551S329P . . . . . . . . . . . . . . . . 35 551S331P . . . . . . . . . . . . . . . . 35 551S332P . . . . . . . . . . . . . . . . 35 551S334P . . . . . . . . . . . . . . . . 35 551S335P . . . . . . . . . . . . . . . . 35 551S337P . . . . . . . . . . . . . . . . 35 551S344P0 . . . . . . . . . . . . . . . 37 551S346P0 . . . . . . . . . . . . . . . 37 551S347P0 . . . . . . . . . . . . . . . 37 551S349P0 . . . . . . . . . . . . . . . 37 551S705P 551S707P 551S708P 551S710P 551S711P 551S713P 551S714P 551S716P 551S720P 551S722P 551S723P 551S725P 551S726P 551S728P 551S729P 551S731P . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 552S0482444 552S0482447 552S0482944 552S0482947 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 Product Number Page Number 552S0483644 552S0483647 552S0602444 552S0602447 552S0602944 552S0602947 552S0603644 552S0603647 552S0722444 552S0722447 552S0722944 552S0722947 552S0723644 552S0723647 552S0962444 552S0962447 552S0962944 552S0962947 552S0963644 552S0963647 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 552S2741P0 552S2741S0 552S2742P0 552S2742S0 552S2743P0 552S2743S0 552S2744P0 552S2744S0 552S2745P0 552S2745S0 552S2746P0 552S2746S0 552S2747P0 552S2747S0 552S2748P0 552S2748S0 552S2749P0 552S2749S0 552S2750P0 552S2750S0 552S2751PB 552S2751SB 552S2752PB 552S2752SB 552S2753PB 552S2753SB 552S2754PB 552S2754SB 552S2755PB 552S2755SB 552S2760PC 552S2760SC 552S2761PC 552S2761SC 552S2762PC 552S2762SC . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 552S326P . . . . . . . . . . . . . . . . 35 552S328P . . . . . . . . . . . . . . . . 35 552S329P . . . . . . . . . . . . . . . . 35 552S331P . . . . . . . . . . . . . . . . 35 552S332P . . . . . . . . . . . . . . . . 35 552S334P . . . . . . . . . . . . . . . . 35 552S335P . . . . . . . . . . . . . . . . 35 552S337P . . . . . . . . . . . . . . . . 35 552S344P0 . . . . . . . . . . . . . . . 37 Product Number Page Number 552S346P0 . . . . . . . . . . . . . . . 37 552S347P0 . . . . . . . . . . . . . . . 37 552S349P0 . . . . . . . . . . . . . . . 37 552S705P 552S707P 552S708P 552S710P 552S711P 552S713P 552S714P 552S716P 552S720P 552S722P 552S723P 552S725P 552S726P 552S728P 552S729P 552S731P . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 41 554S0482432 554S0482435 554S0482932 554S0482935 554S0483632 554S0483635 554S0602432 554S0602435 554S0602932 554S0602935 554S0603632 554S0603635 554S0722432 554S0722435 554S0722932 554S0722935 554S0723632 554S0723635 554S0962432 554S0962435 554S0962932 554S0962935 554S0963632 554S0963635 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 . . . . . . . . . . . . 112 554S2741P0 554S2741S0 554S2742P0 554S2742S0 554S2743P0 554S2743S0 554S2744P0 554S2744S0 554S2745P0 554S2745S0 554S2746P0 554S2746S0 554S2747P0 554S2747S0 554S2748P0 554S2748S0 554S2749P0 554S2749S0 554S2750P0 554S2750S0 554S2751PB . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . . 55 . . . . . . . . . . . . . 57 www.thermo.com/hamilton Thermo Scientific Hamilton Air Flow Products Page Number Product Number 554S2751SB 554S2752PB 554S2752SB 554S2753PB 554S2753SB 554S2754PB 554S2754SB 554S2755PB 554S2755SB 554S2760PC 554S2760SC 554S2761PC 554S2761SC 554S2762PC 554S2762SC . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . 57 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 . . . . . . . . . . . . . . 58 554S326 . . . . . . . . . . . . . . . . . 35 554S328 . . . . . . . . . . . . . . . . . 35 554S329 . . . . . . . . . . . . . . . . . 35 554S331 . . . . . . . . . . . . . . . . . 35 554S332 . . . . . . . . . . . . . . . . . 35 554S334 . . . . . . . . . . . . . . . . . 35 554S335 . . . . . . . . . . . . . . . . . 35 554S337 . . . . . . . . . . . . . . . . . 35 554S344 . . . . . . . . . . . . . . . . . 37 554S346 . . . . . . . . . . . . . . . . . 37 554S347 . . . . . . . . . . . . . . . . . 37 554S349 . . . . . . . . . . . . . . . . . 37 554S350P . . . . . . . . . . . . . . . . 43 554S352P . . . . . . . . . . . . . . . . 43 554S353P . . . . . . . . . . . . . . . . 43 554S355P . . . . . . . . . . . . . . . . 43 554S705 554S707 554S708 554S710 554S711 554S713 554S714 554S716 554S720 554S722 554S723 554S725 554S726 554S728 554S729 554S731 . . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . . 41 554S8810 554S8820 554S8830 554S8840 554S8850 554S8860 . . . . . . . . . . . . . . . . 76 . . . . . . . . . . . . . . . . 76 . . . . . . . . . . . . . . . . 76 . . . . . . . . . . . . . . . . 76 . . . . . . . . . . . . . . . . 76 . . . . . . . . . . . . . . . . 76 Product Number Page Number 950S1160 . . . . . . . . . . . . . . . . 80 950S2090 950S2100 950S2280 950S2380 950S2400 . . . . . . . . . . . . . . . 105 . . . . . . . . . . . . . . . 105 . . . . . . . . . . . . . . . 105 . . . . . . . . . . . . . . . 105 . . . . . . . . . . . . . . . 105 950S4190 . . . . . . . . . . . . . . . 105 950S4200 . . . . . . . . . . . . . . . 105 950S7641 950S7651 950S7661 950S7671 950S7681 950S7691 950S7761 950S7771 950S7781 950S7791 950S7801 950S7811 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 . . . . . . . . . . . . . . . 106 611S7320 . . . . . . . . . . . . . . . 107 619S2480 619S2600 619S2720 619S2840 619S2960 . . . . . . . . . . . . . . . . 63 . . . . . . . . . . . . . . . . 63 . . . . . . . . . . . . . . . . 63 . . . . . . . . . . . . . . . . 63 . . . . . . . . . . . . . . . . 63 950S1120 . . . . . . . . . . . . . . . . 80 161
Similar documents
Hamilton Scientific Fume Hood Accessories Catalog
Manometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Static Pressure Gauge. . ...
More information