Centrimaster GT-3
Transcription
Centrimaster GT-3
Centrimaster GT-3 Belt driven, single inlet centrifugal fans Technical Data Version 12/2002 Centrimaster GT-3 CATALOGUE Contents Contents ...................................................................3 Belt-driven, Single-inlet Centrifugal Fans ...............4 Versions..............................................................5 General Survey Charts .............................................6 Design Fan casing ..........................................................7 Fan inlet.............................................................7 Impellers ............................................................8 Shafts .................................................................8 Bearings .............................................................9 Materials and Finish, Motor ..................................10 Starting of Fans ......................................................11 Tolerances and Quality ..........................................12 Specification Text GTLF...............................................................13 GTLB ..............................................................14 GTHB..............................................................15 Fan Charts – Explanation......................................17 Acoustic Data – Explanation .................................18 Dimensions and Weights, Fan Charts, Acoustic Data GTLF-3-025 ...............................................20-21 GTLB-3-025...............................................22-23 GTLF-3-031 ..............................................24-25 GTLB-3-031...............................................26-27 GTLF-3-040 ...............................................28-29 GTLB/GTHB-3-040 ...................................30-31 GTLF-3-045 ..............................................32-33 GTLB/GTHB-3-045 ...................................34-35 GTLF-3-050 ..............................................36-37 GTLB/GTHB-3-050 ...................................38-39 GTLF-3-056 ..............................................40-41 GTLB/GTHB-3-056 ...................................42-43 GTLF-3-063 ..............................................44-45 GTLB/GTHB-3-063 ...................................46-47 GTLF-3-071 ..............................................48-49 GTLB/GTHB-3-071 ...................................50-51 GTLB/GTHB-3-080 ...................................52-53 GTLB/GTHB-3-090 ...................................54-55 GTLB/GTHB-3-100 ...................................56-57 GTLB-3-112...............................................58-61 GTLB-3-125...............................................62-65 GTLB-3-140...............................................66-69 Motor Data .......................................................70-76 Accessories Plummer block with grease nipple ...................77 Flexible connections, inlet................................78 Protective screen, inlet .....................................78 Flexible connections, outlet..............................79 Protective screen, outlet ...................................79 Counterflange, outlet .......................................79 Inspection cover ...............................................80 Drain ...............................................................80 Anti-vibration mountings .................................80 Flow measurement device.................................81 Painted finish...................................................82 Motor cover .....................................................82 Ordering codes..................................................83-84 Fläkt Woods Oy FIFLO 4249 GB 02.12 3 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Belt-driven, Single-inlet Centrifugal Fans The type GT CENTRIMASTER belt-driven, singleinlet centrifugal fans cover air flows up to 27 m3/s and pressure rises up to 3.300 Pa. The fan series consists of centrifugal fans available with two types of impeller: – Impeller with forward-curved blades for the GTLF fans – Impeller with backward-curved blades for the GTLB and GTHB fans The backward-curved blades in the GTLB fans have the same aerodynamic characteristics as those in the GTHB fans, but the GTHB is a reinforced version for higher speeds. Fläkt Woods Oy FIFLO 4249 GB 02.12 4 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Versions Besides the normal version, the fans are also available in a spark-proof version. The smoke extraction version of GT has been tested by the French CTICM institute and by the Russian VNIIPO institute. CTICM has tested the fans for +400 °C, 2 hours and the tests cover GTLB-3-025–140 as well as GTLF-3031–071. VNIIPO has tested the fans for +400 °C, 2 hours and for +600 °C, 1 hour and the tests cover all single inlet GT-fans. As compared with the normal version, the fans in the smoke extraction version have metallic bearing dampers. The fans in the spark-proof version conform to the provisions of German Standard VDMA 24 169 3.1 – 3.2 and 3.4. The inlet cone is made of brass and in the GTLF fans the inlet is fitted with a brass band. GTLB The single-inlet fans are rated for continuous operation at temperatures up to +80 °C if the inlet of the fan is connected to the ducting. If the motor is exposed to the air stream, i.e. on afree inlet fan, the ambient temperature must not exceed +40 °C. Motors for higher temperatures are available to special order. GTHB with painted finish GTLF Fläkt Woods Oy FIFLO 4249 GB 02.12 5 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE General Survey Charts GTLF-3250 500 1000 2500 5000 10 000 25 000 50 000 Air flow, m3/h 3000 Sizes 025–071 2000 025 1000 040 031 045 050 Total pressure rise, Pa 056 063 071 500 200 100 0 0,1 0,2 0,5 1 2 3 4 5 10 15 Air flow, m3/s GTLB/GTHB-3200 250 500 1000 2500 5000 10 000 25 000 50 000 Air flow, m3/h 4000 Sizes 025–140 090 080 045 040 2000 050 056 063 071 025 1000 031 100 112 Total pressure rise, Pa 500 125 140 200 100 0 0,1 0,2 0,5 1 2 3 4 5 10 15 30 Air flow, m3/s Fläkt Woods Oy FIFLO 4249 GB 02.12 6 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Design Fan Casing – Sizes 025–071 Fan Inlet The fan casing is made of Sendzimir galvanised sheet steel. The casing side plates are stamped in one piece and the inlets are deep-pressed in the end walls. The fan casing is jointed by the "Pittsburg folding method" which produces tight, strong joints. This jointing method and the deep-pressed inlets guarantee a stable design and high, consistent quality. The fan tongue has been specially designed to offer optimised aerodynamic properties. The design of the fan inlet is of vital importance to high fan efficiency and a low level of sound generated by the fan. On the size 025–071 GTLF fans, the inlet is directly deep-pressed into the end walls. On the GTLB and GTHB fans the inlet must be deeper and must also extend into the impeller with a certain amount of overlap and a small, accurately predetermined radial gap. The inlet cones of the GTLB and GTHB fans are deepdrawn in one piece and are fitted to end walls of GTLF fans. This means that the GTLB and GTHB fans have a "double inlet" that gives the fan casing additional rigidity. On the size 080–140 fans, the inlet cone is made separately for both types of fan and directly fitted to the end walls. Fan Casing – Sizes 080–140 The fan casing is made of Sendzimir galvanised sheet steel. The casing of the size 080 and 090 fans is jointed by the Pittsburg folding method and the casing is as standard equipped with a stable, welded frame. The casing of the size 100–140 fan consists of five flanged sections that can be dismantled. Pittsburg Tunga för GTLB- och GTHB-fläktar Fläkt Woods Oy FIFLO 4249 GB 02.12 7 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Design Fan Impellers Shafts The fan impellers with backward-curved blades (GTLB and GTHB) are made of sheet steel and welded, coated with 60 mm thick epoxy powder, (colour: AM 8043, dark grey). The fan impellers with forward-curved blades (GTLF) are made of Sendzimir galvanised sheet steel. The impellers of the size 040–140 GTLB and GTHB fans are dynamically balanced to an accuracy to ISO 1940–1973 G 2.5 at the maximum speed. The impeller of the size 025–031 GTLB fans and all sizes of GTLF fans are dynamically balanced to accuracy according to ISO Standard 1940–1973 G 6.3 at the maximum speed. The impeller of the size 025–100 fans is secured to the shaft by means of a key. The shafts are made of steel and are provided with keyways for the belt pulleys. The shafts are designed with a high factor of safety against fatigue, and for a critical speed, which is at least 20% higher than the maximum fan speed. The shafts have anti-corrosion protection. Fan impeller of the type GTHB fans Fan impeller of the type GTLF fans Fläkt Woods Oy FIFLO 4249 GB 02.12 8 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Design Bearings The size 025–071 GTLB and GTLF fans are equipped with single-row, deep-groove ball bearings (Y-bearings) that are permanently lubricated and sealed on both sides. These bearings are secured to the shaft by means of an eccentric locking collar. The bearings are supported by robust three-armed or four-armed bearing support. The size 080–100 GTLB fans are equipped with singlerow, deep-groove ball bearings seated in plummer blocks with grease nipple. These bearings are secured to the shaft by means of a tapered adapter sleeve. The bearings of the GTLB and GTLF fans are designed for a life cycle of 20.000 hours. The plummer blocks with grease nipple are supplied as accessories for the size 025–071 GTLF and GTLB fans. See under Accessories. Bearing of the type GTLF and GTLB fans up to size 071. The size 040–071 GTHB fans are equipped with singlerow, deep-groove ball bearings that are permanently lubricated and sealed on both sides. These bearings are secured to the shaft by means of a tapered adapter sleeve. This means that the dimension of the bearing increases by 5 mm in relation to the shaft and this increases the useful life of the bearing. The bearings are supported by a robust three-armed or four-armed bearing support. Plummer blocks with grease nipple are also available as accessories. Bearing of the size 080 – 100 GTLB fans. The size 080–100 GTHB fans and the size 112–140 GTLB fans are equipped with plummer blocks with roller bearings secured to a sturdy bearing bracket made of welded flat iron bar. All the roller bearings are as standard equipped with grease nipples. The bearings of the GTHB fans are designed for a life cycle of 40.000 hours. GTHB-040-071 GTHB-080-100 and GTLB-112-140 Fläkt Woods Oy FIFLO 4249 GB 02.12 9 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Materials and Finish, Motor Selecting the Motor Materials and Finish The shaft power (P, kW) and the recommended min. permissible motor output for direct on-line starting (PM, kW) are specified in the fan charts, i.e. the safety factor is already included. Base your motor selection on this PM figure. The GX fans in the standard version meet the provisions of Environmental Class M2. Fan casing: Inlet cone: Shaft: Fan impeller: Sendzimir galvanised sheet steel, (275 g/ m2 thick zinc) Sendzimir galvanised sheet steel in the normal version. Brass in the spark-proof version. Centreless-ground steel with anti-corrosion protection. GTLB and GTHB: Sheet steel, welded, coated with 60 mm epoxy powder and baked, colour: AM8043, dark grey. GTLF: Sendzimir galvanised steel. The safety factor covers belt losses that arise with standardised belt pulleys. Recommendations: When selecting GTLB and GTHB fans (with backward-curved blades) that at a given speed have an output peak within their operating range, use this output peak for selecting a motor and not the output at the duty point. When selecting GTLF fans (with forward-curved blades) whose power demand, at a given speed, continuously increases as the air flow increases, use the shaft power demand P at the duty point (adding the safety factor!) or the recommended min. permissible motor output PM. If you cannot with certainty plot the duty point in the fan chart, select a motor for an output that is another 15–20 % higher. Motor The GT fans are normally supplied with the motor mounted. This enables the fan to be trial run prior to dispatch and ABB can assume undivided warranty liability. If the fan is supplied without motor, the size and speed of the motor must be specified when the order is placed so that the correct belt drive can be selected. Detailed motor data is tabulated in separate tables. See under Motor Data. Belt Drive The belt drive consists of belt pulleys and belt(s). The pulleys have a separate Taper-Lock-type hub, which is easy to fit and remove. The belt guard and slide rails are included in the GT fan delivery. Fläkt Woods Oy FIFLO 4249 GB 02.12 10 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Starting of Fans Power demand of the fan Transmission losses Motor output required to operate fan Select the motor Select starting procedure Direct on-line or star-delta starting Calculate the starting time Starting time is too long Check the permissible motor starting time Equipment for heavy starting Select the starter Starting time is too long Check the tripping time of the overload protection To calculate the starting time in direct on-line starting Use the following formula: Symbols used The calculated starting time is the time needed for accelerating the fan from rest to full speed. To calculate the starting time in star-delta starting Use the following formula: FIFLO 4249 GB 02.12 = motor rating ............................................ kW Pm 1) = power demand with the fan running at rated speed (including any belt-drive losses) ...... kW PY/D = lowest rating of motor for which star-delta staringcan be employed ............... kW Mst 3) ––––– M Mmax3) ––––– M nf J2) = ratio of motor starting torque to normal torque t = starting time ................................................ s = ratio of maximum motor torque to normal torque = rated speed of fan ................................. r/min = Moment of inertia of the system referred to the fan shaft ........................ kg m2 1) PM som redovisas i vissa katalogavsnitt. 2) The moment of inertia of the impeller is given in the fan charts. The moment of inertia of the motor can generally be disregarded. 3) See the catalogue of the motor supplier. The calculated starting time is the time during which the stardelta starter must be in star for the fan to reach about 90 % of full speed, whereupon the starter switches over to delta. On star-delta starting, also check that the motor curve is higher than the fan torque curve during the star connection period. The lowest possible motor rating for star-delta starting can be calculated from the following expression. Fläkt Woods Oy P 11 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Tolerances and Quality ISO 9001 and ISO 14001 Quality Tolerances The particulars in the charts of the size 040–140 GTLB- and GTHB fans are given with the tolerance specified in the DIN 24 166 Standard, Class 1. Tolerance Class 2 is applicable to the size 025–031 GTLB fans and all the GTLF fans. Fläkt Woods has received quality management certification in accordance with ISO 9001. We document our quality management responsibility at every stage of our business activities from the product development to production, procurement and marketing. We have received environmental management certification in accordance with ISO 14001. We aim to minimise the impact of our business activities and our products on the environment. Tolerance Class DIN 24166 1 2 3 Air flow qv: ±2,5% ±5,0% ±10,0% Pressure rise, ∆pt: ±2,5% ±5,0% ±10,0% Shaft power demand*, P: +3,0% +8,0% +16,0% Efficiency**, h: –2,0% –5,0% – A-weighted sound power level*, LWA: +3 dB +4 dB +6 dB * Negative tolerance permissible ** Positive tolerance permissible Fläkt Woods Oy FIFLO 4249 GB 02.12 12 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Specification Text – GTLF GXLF GTLF Fan details for the GTLF in accordance with DIN 24166, Class 2 Single-inlet centrifugal fan for a belt-drive. The fan casing is made of Sendzimir galvanised sheet steel, jointed by the "Pittsburg folding method". Fan impeller with forward-curved blades, made of Sendzimir galvanised sheet steel. The fan impeller is dynamically balanced to accuracy according to ISO Standard 1940 – 1973 G 6.3. The shaft is designed for a critical speed, which is at least 20% higher than the maximum fan speed. Single-row, deep-groove ball bearings are permanently lubricated and sealed on both sides. These bearings are secured to the shaft by means of an eccentric locking collar. The bearings are supported by three-arm or four-arm bearing supports. The specified aerodynamic performance has been measured in accordance with AMCA 210-85 and 300-85. The quality management system of the supplier has been granted ISO 9001 certification and his environmental management system has been granted ISO 14001 certification. Air flow, qv .........................................................m3/s Total pressure rise, ∆pt ........................................Pa Power demand, P................................................kW Min. fan efficiency, η .........................................% Max. A-weighted total sound power level, LWA ...dB – Normal version – Smoke extraction version – can withstand 400 °C for 2 hours – Spark-proof version Fläkt Woods Oy FIFLO 4249 GB 02.12 13 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Specification Text – GTLB GTLB Fan details for the GTLB in accordance with DIN 24166 Sizes 040–140: Class 1 Sizes 025–031: Class 2 The quality management system of the supplier has been granted ISO 9001 certification and his environmental management system has been granted ISO 14001 certification. Single-inlet centrifugal fan for a belt-drive. The fan casing is made of Sendzimir galvanised sheet steel, jointed by the "Pittsburg folding method", in size 100 consisting of five sections with flanges. Fan impeller with backward-curved blades, made of sheet steel, welded and coated with 60 mm thick epoxy powder. The fan impeller is dynamically balanced to accuracy according to ISO Standard 1940 – 1973 G 2.5 (sizes 040–140) or G 6.3 (sizes 025–031). The shaft is designed for a critical speed, which is at least 20% higher than the maximum fan speed. Singlerow, deep-groove ball bearings are permanently lubricated and sealed on both sides. These bearings are secured to the shaft by means of an eccentric locking collar. The bearings are supported by three-arm or four-arm bearing supports. The size 080–100 fans are equipped with plummer blocks with ball bearings and the size 112–140 with plummer blocks with roller bearings fitted to a sturdy bearing bracket made of welded flat iron bar. The specified aerodynamic performance has been measured in accordance with AMCA 210-85 and 300-85. Air flow, qv................................................................m3/s Total pressure rise, ∆pt ..............................................Pa Power demand, P ......................................................kW Min. fan efficiency, η ................................................% Max. A-weighted total sound power level, LWA .........dB – Normal version – Smoke extraction version – can withstand 400 °C for 2 hours – Spark-proof version Fläkt Woods Oy FIFLO 4249 GB 02.12 14 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Specification Text – GTHB GTHB Fan details for the GTHB in accordance with DIN 24166, Class 1 The quality management system of the supplier has been granted ISO 9001 certification and his environmental management system has been granted ISO 14001 certification. Single-inlet centrifugal fan for a belt-drive. The fan casing is made of Sendzimir galvanised sheet steel, jointed by the "Pittsburg folding method", in size 100 consisting of five sections with flanges. Fan impeller with backward-curved blades, made of sheet steel, welded, coated with 60 mm thick epoxy powder and baked. The fan impeller is dynamically balanced to accuracy according to ISO Standard 1940 – 1973 G 2.5. The shaft is designed for a critical speed, which is at least 20% higher than the maximum fan speed. The size 040–071 GTHB fans are equipped with singlerow, deep-groove ball bearings that are permanently lubricated and sealed on both sides. These bearings are secured to the shaft by means of a tapered adapter sleeve. The bearings are supported by a robust three-armed or four-armed bearing support. The size 080–100 GTHB fans are equipped with plummer blocks with roller bearings secured to a sturdy bearing bracket made of welded flat iron bar. The roller bearings are as standard equipped with grease nipples. The specified aerodynamic performance has been measured in accordance with AMCA 210-85 and 300-85. Air flow, qv................................................................m3/s Total pressure rise, ∆pt ..............................................Pa Power demand, P ......................................................kW Min. fan efficiency, η ................................................% Max. A-weighted total sound power level, LWA .........dB – Normal version – Spark-proof version Fläkt Woods Oy FIFLO 4249 GB 02.12 15 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Notes Fläkt Woods Oy FIFLO 4249 GB 02.12 16 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Explanation 10 The GT fan charts on the following pages are applicable to air with a density of 1.2 kg/m3. 1 = Air flow, m3/s (x-axis) 3000 3 = Air flow, 80 3000 1000 7 8 3000 .997 60 2500 .991 2000 .981 40 1500 500 80 L wA,dB 75 1000 r/min 200 85 90 95 = Total sound power level LwA (dB), broken line 6 0 1 qv 2000 = Power demand, P (kW) 0.1 3 m 3/s 2 4000 6000 8000 7 10000 1 m 3/h 2 1000 0.2 = Min. recommended motor rating for direct online starting, PM (kW) 1500 .959 100 1000 .903 100 50 J = 0.24 kgm 2 9 1500 P,kW 6 75 5 4 ∆p t ,Pa = Fan efficiency η, % 3500 1 2000 3 5 r/min η-korr 2500 = Total pressure rise, Pa (y-axis) = Fan speed, r/min η,% GTLBmax 2800 (x-axis) 4 GTHB-3-040 GTLB-3-040 81 0.5 1 1 2000 P M ,kW 2 80 GTHBmax 3500 2000 m3/h 15 3500 8 2 9 = Moment of inertia, J (kg = Fan size 11 = Dynamic pressure at the outlet, pd 12 = Connection loss at the inlet, ∆p1 2800 3000 3 = Connection loss at the outlet, ∆p2 + pd 14 = Protective screen at the inlet, ∆p3 15 = Protective screen at the outlet, ∆p4 11 pd ∆p 1 12 ∆ p 2 + pd 13 4 6 3500 r/min 6 7 14 16 2500 4 10 13 2 m2) ∆p 3 ∆p 4 10 20 5 8 60 10 40 80 100 20 30 100 10 160 40 200 250 60 200 Pa 80 Pa 400 Pa 300 20 40 60 70 Pa 20 40 60 Pa = Correction factor for the efficiency kη = Recommended operating range = Recommended operating range of a heavy-duty fan The charts for fans with backward-curved blades include a kη scale that indicates how much the efficiency will decrease if the fan is running at low speed. This scale can be applied with high precision within the normal operating range at which the power consumption of the fan at a given speed is fairly independent of the air flow. The bearing losses are included in the power consumption of the fan and influence its efficiency. The power consumed by the fan is defined in the fan chart as the power consumed at the shaft end and thus contains the bearing losses. The efficiency figures in the chart are applicable to a fan operating at max. speed. Fläkt Woods Oy FIFLO 4249 GB 02.12 17 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Acoustic Data – Explanation Acoustic Data Correction Kokt, dB A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: LWokt(s) = LWA + Kokt(s) Where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: Speed range Sound path (s) LWA(s) – LWt(s) – Octave band, mid-frequency, Hz 1 000 2 000 4 000 LWA LWA(s) 8 000 dB dB r/min 63 125 250 500 To outlet duct (1) 0 – 964 965 – 1928 1929 – 3200 0 -2 -3 5 -1 -4 2 3 -4 -3 -3 -1 -6 -6 -6 -9 -9 -8 -14 -14 -13 -18 -17 -16 0 0 0 8.2 6.4 4.1 To inlet duct (2) 0 – 964 965 – 1928 1929 – 3200 4 2 -2 3 -1 -5 0 0 -6 -3 -3 -2 -4 -5 -4 -9 -8 -7 -12 -10 -9 -14 -13 -14 0.4 0.3 0.8 7.8 6.2 3.3 To surroundings – the fan inlet and outlet ducted (3) 0 – 964 965 – 1928 1929 – 3200 -8 -10 -12 -5 -8 -14 -6 -6 -11 -8 -10 -8 -11 -12 -10 -15 -16 -16 -22 -25 -24 -33 -36 -35 -6.1 -7.3 -6.4 6.1 5.8 3.1 To fan outlet (open-discharge fan) (4) 0 – 964 965 – 1928 1929 – 3200 -9 -13 -17 0 -6 -9 0 1 -6 -3 -3 -1 -6 -6 -6 -9 -9 -8 -14 -14 -13 -18 -17 -16 -0.6 -0.5 -0.1 5.5 4.5 2.3 LWA(s) = LWA + [LWA(s) – LWA] where the correction figure LWA(s) – LWA can be obtained from the table. The table also includes correction figures LWt(s) – LWA(s) that can be used for obtaining the total sound power level on each sound path: LWt(s) = LWA(s) + [LWt(s) – LWA(s)] Description of sound path 1 = To outlet duct 2 = To inlet duct 3 = To inlet duct (the fan inlet and outlet ducted) Test arrangement 2 1 3 4 = To fan outlet (for open-discharge fan) 2 4 3 Symbols used LWA s LWA(s) LWt(s) LWokt(s) Kokt(s) L ∆L LpA(s) A-weighted sound power level emitted to outlet duct Sound path A-weighted sound power level equivalent to sound path s Total sound power level (without frequency weighting A), (corresponding to sound path s) Total sound power level at each octave band (without frequency weighting A), (corresponding to sound path s) Correction figure for breaking down sound level at each octave band, (corresponding to sound path s) Distance Distance absorption (applicable to ideal conditions with hemispherical sound propagation) A-weighted sound power level at distance L from fan, (corresponding to sound path s) Fläkt Woods Oy FIFLO 4249 GB 02.12 18 dB(A) dB(A) dB dB dB m dB dB(A) Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Acoustic Data – Explanation Distance absorption The following formula is used to obtain the sound pressure level LpA(s) on free sound emission to the surroundings (sound paths 3 and 4) at various distances L: LpA(s) = LWA(s) – ∆L where the distance absorption ∆L can be obtained from the table below: L, m 1 3 5 10 15 20 25 30 40 50 75 100 ∆L, dB 8 17 22 28 31 34 36 37 40 42 45 48 Example: GTHB-3-045: Air flow qv = 2.2 m3/s, total pressure rise ∆pt = 1800 Pa. From fan chart: Speed n = 2670 r/min. Power demand P = 5.25 kW. Fan efficiency η = 0.996 x 80% = 79.7%. A-weighted sound power level to outlet duct LWA = 95.7 dB(A). If the fan has a ducted inlet and outlet, the sound level at each octave band and the total sound power level for each sound path will be the following: Inlet duct: LW63Hz = 95.7 – 2 = 93.7 dB LWA = 95.7 + 0.8 = 96.5 dB(A) LWt = 96.5 + 3.3 = 99.8 dB Sound path 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz LwA. dB(A) Lwt. dB Outlet duct 92.7 91.7 91.7 94.7 89.7 87.7 82.7 79.7 95.7 99.8 Inlet duct 93.7 90.7 89.7 93.7 91.7 88.7 86.7 81.7 96.5 99.8 Surroundings (the fan inlet and outlet ducted) 83.7 81.7 84.7 87.7 85.7 79.7 71.7 60.7 89.3 98.8 The A-weighted sound power level at a distance of one metre from the fan will be: LpA = 89.3–7 = 82.3 dB(A) If the fan has an open discharge, the A-weighted sound power level at the fan outlet will be: LwA = 95.7–0,1 = 95.6 dB(A). The corresponding sound power level at a distance of 50 metres will be: LpA = 95.6–42 = 53.6 dB(A). Fläkt Woods Oy FIFLO 4249 GB 02.12 19 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLF-3-025 Dimensions and Weights 381 Right-hand version with 90° direction of discharge shown 346 Fan shaft 45 239 6 174 ø9 22,5 Max. IEC112 20 213*) 248 388 486 ø 244 215 713*) 753 36*) 7 188 *) Distance between the anti-vibration mountings 30 Right-hand version (viewed from drive side) 322 30 473 322 456 493 322 299 261 167 33 43 771 30 230 90° 165 851 785 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLF-3-025: 17,5 Belt drive: 3,0 270° Outlet flange 239 ø10 15 19,5 15 19,5 15 4,5 322 179 209 219 Motor data: See separate motor list. FIFLO 4249 GB 02.12 382 352 ø10 Fläkt Woods Oy 2 x 176 362 20 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLF-3-025 Belt-driven, single-inlet, forward-curved blades 2500 r/min 3000 58 50 GTLF-3-025 2000 η,% Impeller diameter: 250 mm 50 2500 1000 1500 500 ∆p t ,Pa 40 2000 95 90 1000 L wA,dB 85 200 100 50 0.2 0.6 qv 1000 0.1 1.4m 3/s 1 2000 3000 1000 J = 0.02 kgm 2 P M ,kW 0.2 P,kW 5000 m 3/h 4000 1500 2000 1 Acoustic Data 1 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 2500 2 3000 2 r/min 4 3.5 pd 50 ∆p 1 10 20 ∆ p 2 + pd ∆p 3 Lwokt(s)=LWA+Kokt(s) 100 100 40 20 10 80 40 60 r/min 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 1116 1117 – 2233 2234 – 3000 4 5 5 5 4 2 1 -1 -3 -3 -6 -5 -7 -5 -7 -10 -8 -7 To inlet duct (2) 0 – 1116 1117 – 2233 2234 – 3000 8 7 6 -1 1 1 -4 -8 -5 -8 -11 -9 -6 -6 -9 To surroundings – the fan inlet and outlet ducted (3) 0 – 1116 1117 – 2233 2234– 3000 -8 -8 -8 -6 -7 -7 -5 -8 -10 -4 -10 -10 To fan outlet (open-discharge fan) (4) 0 – 1116 1117 – 2233 2234– 3000 -15 -16 -18 -3 -6 -10 -3 -5 -7 -5 -8 -6 Fläkt Woods Oy 80 80 Sound path (s) Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 100 120 Pa 100 100 Correction, Kokt, dB Speed range FIFLO 4249 GB 02.12 21 Pa 600 60 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 400 Pa 400 40 20 300 60 200 10 ∆p 4 30 200 Pa 120 Pa LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -10 -9 -8 -12 -11 -11 0 0 0 9 8.7 7.9 -12 -10 -8 -13 -10 -9 -19 -15 -12 -2.4 -2.0 -1.7 11.5 10.4 9.6 -7 -7 -8 -12 -9 -6 -17 -17 -13 -22 -23 -20 -2.6 -3.3 -2.1 4.1 3.2 2.2 -7 -5 -7 -10 -8 -7 -10 -9 -8 -12 -11 -11 -1.3 -0.6 -0.6 3.9 2.2 1.4 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB-3-025 Dimensions and Weights 381 Right-hand version with 90° direction of discharge shown 346 Fan shaft 45 239 6 174 ø9 22,5 Max. IEC112 20 213*) 248 388 486 ø 244 215 713*) 753 36*) 7 188 *) Distance between the anti-vibration mountings 30 Right-hand version (viewed from drive side) 322 30 473 322 456 493 322 299 261 167 33 43 771 30 230 90° 165 851 785 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLB-3-025: 18,5 Belt drive: 3,0 270° Outlet flange 239 ø10 15 19,5 15 19,5 15 4,5 322 179 209 219 Motor data: See separate motor list. FIFLO 4249 GB 02.12 382 352 ø10 Fläkt Woods Oy 2 x 176 362 22 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB-3-025 Belt-driven, single-inlet, backward-curved blades 2200 2000 75 4500 75 4500 1 η,% 4000 Impeller diameter: 250 mm r/min η-korr GTLB-3-025 76 70 4000 .993 3500 3500 .982 60 1000 3000 3000 .966 2500 40 500 2500 .941 ∆p t ,Pa 2000 Only the GTLB is available in the smoke extraction version. L wA,dB 70 1500 200 75 80 85 90 95 2000 .898 r/min 1500 .817 100 50 0 500 0.2 qv 0.4 1000 0.6 1500 2000 1 m 3/s 0.8 2500 3500 m 3/h 3000 0.01 1500 J = 0.03 kgm 2 0.1 2000 0.1 0.2 2500 0.2 Acoustic Data 0.4 3000 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 3500 0.6 0.8 1 4000 1 1.4 4500 r/min 1.8 1.6 pd 10 ∆p 1 20 5 60 10 ∆ p 2 + pd Lwokt(s)=LWA+Kokt(s) 80 100 120 20 40 30 ∆p 3 10 20 ∆p 4 10 20 30 r/min 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 1928 1929 – 3857 3858 – 4500 1 -2 -4 2 0 -3 3 -7 -3 -4 0 -7 -7 -7 -3 -8 -10 -8 To inlet duct (2) 0 – 1928 1929 – 3857 3858 – 4500 1 -1 -4 2 0 -2 3 -8 -4 -4 -0 -7 -5 -5 -2 To surroundings – the fan inlet and outlet ducted(3) 0 – 1928 1929 – 3857 3858 – 4500 -7 -11 -13 -5 -10 -13 -4 -10 -9 -9 -8 -14 To fan outlet (open-discharge fan) (4) 0 – 1928 1929 – 3857 3858 – 4500 -16 -21 -25 -6 -9 -13 -1 -11 -7 -5 -1 -8 Fläkt Woods Oy 200 Pa 50 Pa 40 Pa 40 Pa Correction, Kokt, dB Speed range FIFLO 4249 GB 02.12 23 60 Pa 200 Sound path (s) Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 160 40 100 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: P M ,kW P,kW 0.05 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -13 -12 -11 -16 -15 -15 0 0 0 7.5 5.1 3.7 -10 -11 -10 -13 -12 -12 -18 -17 -17 0 0.3 0.1 7.6 5.1 3.8 -12 -11 -10 -14 -18 -16 -21 -23 -22 -31 -34 -34 -6.1 -7.0 -7.5 6.7 4.3 3.5 -7 -7 -3 -8 -10 -8 -13 -12 -11 -16 -15 -15 -1.3 -0.8 0.3 3.9 2.3 1.0 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLF-3-031 Dimensions and Weights 419 Right-hand version with 90° direction of discharge shown Fan shaft 50 393 277 8 212 ø9 28 Max. IEC132 25 253*) 286 495 591 ø 310 250 820*) 860 36*) 33 203 *) Distance between the anti-vibration mountings 30 Right-hand version (viewed from drive side) 404 30 548 404 528 613 404 379 292 187 38 92 935 33 249 90° 203 952 923 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLF-3-031: 23,5 Belt drive: 4,0 270° Outlet flange 277 ø10 15 19,5 15 19,5 15 4,5 404 217 247 257 Motor data: See separate motor list. FIFLO 4249 GB 02.12 464 434 ø10 Fläkt Woods Oy 2 x 217 444 24 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLF-3-031 Belt-driven, single-inlet, forward-curved blades 2500 r/min 2400 50 60 η,% 62 60 2000 2200 Impeller diameter: 315 mm 2000 50 1800 1000 1600 40 1400 1200 95 1000 800 200 90 L wA,dB 85 600 100 GTLF-3-031 50 0.2 1 3000 1.4 4000 P,kW 0.2 1 Acoustic Data 2 2 m 3/s 1.8 5000 600 800 1000 1200 1400 1600 1800 2000 2200 2400 r/min 0.1 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 0.6 qv 2000 7000 m 3/h 6000 0.2 J = 0.05 kgm 2 1 P M ,kW ∆p t ,Pa 500 2 4 4 7 6 pd 50 ∆p 1 10 ∆ p 2 + pd 50 20 200 40 40 20 80 Pa 100 Pa Pa 400 20 10 300 60 200 10 ∆p 4 30 100 ∆p 3 Lwokt(s)=LWA+Kokt(s) 100 60 40 60 80 80 Pa 100 Pa where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: Sound path (s) r/min 63 125 250 500 8 000 dB LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 1010 1011 – 2020 2021 – 2400 3 5 5 4 4 4 -2 -2 -3 -2 -6 -7 -7 -5 -7 -9 -8 -6 -10 -9 -8 -11 -13 -12 0 0 0 8.0 8.6 8.5 To inlet duct (2) 0 – 1010 1011 – 2020 2021 – 2400 7 7 7 -3 -1 1 -6 -7 -6 -5 -9 -7 -4 -3 -8 -10 -8 -6 -12 -10 -8 -19 -15 -12 -0.8 -0.1 -0.5 9.0 8.5 9.2 To surroundings – the fan inlet and outlet ducted (3) 0 – 1010 1011 – 2020 2021 – 2400 -9 -8 -8 -6 -7 -9 -4 -6 -10 -3 -10 -12 -7 -7 -8 -11 -9 -5 -17 -17 -13 -21 -25 -21 -1.9 -3.3 -1.7 3.9 3.5 1.6 To fan outlet (open-discharge fan) (4) 0 – 1010 1011 – 2020 2021 – 2400 -13 -12 -13 -3 -4 -3 -5 -5 -6 -3 -7 -8 -7 -5 -7 -9 -8 -6 -10 -9 -8 -11 -13 -12 -0.7 -0.6 -0.5 3.4 2.7 2.6 where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] Fläkt Woods Oy Correction, Kokt, dB Speed range FIFLO 4249 GB 02.12 25 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz 1 000 2 000 4 000 LWA LWA(s) dB Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB-3-031 Dimensions and Weights 419 Right-hand version with 90° direction of discharge shown Fan shaft 50 393 277 8 212 ø9 28 Max. IEC132 25 253*) 286 495 591 ø 310 250 820*) 860 36*) 33 203 *) Distance between the anti-vibration mountings 30 Right-hand version (viewed from drive side) 404 30 548 404 528 613 404 379 292 187 38 92 935 33 249 90° 203 952 923 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLB-3-031: 25,0 Belt drive: 4,0 270° Outlet flange 277 ø10 15 19,5 15 19,5 15 4,5 404 217 247 257 Motor data: See separate motor list. FIFLO 4249 GB 02.12 464 434 ø10 Fläkt Woods Oy 2 x 217 444 26 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB-3-031 Belt-driven, single-inlet, backward-curved blades 2200 2000 75 3600 77 3400 3200 Impeller diameter: 315 mm r/min η-korr GTLB-3-031 3600 1 η,% 3400 .997 75 3000 3200 .994 70 2800 3000 .99 2600 1000 2800 .985 60 2400 2600 .979 2200 2400 .972 2000 2200 .963 40 1800 500 2000 .951 ∆p t ,Pa 1600 Only the GTLB is available in the smoke extraction version. 1800 .936 1400 1600 .915 1200 r/min L wA,dB 70 200 75 80 85 90 1200 .845 100 50 0 0.4 qv 1000 0.05 P,kW 0.1 Acoustic Data 0.2 0.6 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 1 1.4 2 2.2 0.8 2000 10 ∆p 1 4000 5 2 2.6 60 10 80 100 120 20 40 30 100 160 200 Pa 50 60 Pa 40 300 Pa 200 ∆p 3 10 20 40 Pa ∆p 4 10 20 40 Pa Sound path (s) r/min 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 1928 1929 – 3600 1 -1 -1 -2 4 -6 -4 -2 -7 -6 -8 -7 To inlet duct (2) 0 – 1928 1929 – 3600 1 -2 -1 -5 3 -9 -1 0 -5 -4 To surroundings – the fan inlet and outlet ducted (3) 0 – 1928 1929 – 3600 -7 -10 -8 -12 -5 -9 -9 -9 To fan outlet (open-discharge fan) (4) 0 – 1928 1929 – 3600 -13 -18 -8 -9 1 -9 -5 -3 Fläkt Woods Oy 0.2 1 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] m 3/h 0.1 5000 J = 0.085 kgm2 20 ∆ p 2 + pd Lwokt(s)=LWA+Kokt(s) 3000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 r/min pd 1.6 m 3/s 1.2 P M ,kW Note: Max. speed of the smoke extraction version is 3100 rpm. where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 1400 .886 95 Correction Kokt, dB Sound path (s) FIFLO 4249 GB 02.12 27 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -15 -12 -17 -16 0 0 7.3 4.5 -10 -8 -11 -10 -16 -16 0.9 1.0 6.4 3.4 -12 -10 -14 -15 -23 -23 -32 -35 -6.4 -6.4 6.0 3.8 -7 -6 -8 -7 -15 -12 -17 -16 -1.1 -0.6 4.5 1.8 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLF-3-040 Dimensions and Weights 516 Right-hand version with 90° direction of discharge shown 452 Fan shaft 50 329 8 263 ø9 33 Max. IEC132 30 303*) 338 543 744 ø 388 312 945*) 985 36*) 41 249 *) Distance between the anti-vibration mountings 30 Right-hand version (viewed from drive side) 507 30 600 507 764 653 507 469 363 239 38 121 1075 41 310 203 1130 90° 1041 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLF-3-040: 39,0 Belt drive: 4,0 270° Outlet flange 329 - 149,5 ø10 15 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 4x 134,3 546 567 537 507 269 299 308 28 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLF-3-040 Belt-driven, single-inlet, forward-curved blades 2000 r/min 1700 65 η,% 60 1600 60 Impeller diameter: 400 mm 1400 1000 1200 50 1000 40 500 100 600 200 95 90 L wA,dB 85 100 GTLF-3-040 50 0.5 1 qv 4000 2000 3 m 3/s 2 6000 8000 10000 m 3/h 0.1 0.2 0.2 600 P,kW 1000 1 1 1200 Acoustic Data 2 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: J = 0.14 kgm 2 800 1400 2 1600 1700 r/min 3 5 4 7 6 pd 50 ∆p 1 100 10 ∆ p 2 + pd 20 50 40 20 10 40 20 40 60 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: Sound path (s) r/min 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 1010 1011 – 1700 4 5 3 2 -2 -4 -3 -6 -6 -5 -8 -7 To inlet duct (2) 0 – 1010 1011 – 1700 5 6 2 -1 -7 -10 -6 -8 -3 -3 To surroundings – the fan inlet and outlet ducted (3) 0 – 1010 1011 – 1700 -8 -8 -6 -7 -4 -8 -4 -10 To fan outlet (open-discharge fan) (4) 0 – 1010 1011 – 1700 -11 -11 -3 -4 -4 -6 -4 -7 where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] Fläkt Woods Oy Pa 60 200 10 ∆p 4 200 30 100 ∆p 3 Lwokt(s)=LWA+Kokt(s) 80 Speed range 29 Pa 400 Pa 60 Pa 80 Correction, Kokt, dB FIFLO 4249 GB 02.12 P M ,kW ∆p t ,Pa 800 Pa LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -10 -9 -14 -13 0 0 7.9 7.8 -7 -6 -10 -10 -16 -14 0.4 0.4 7.4 7.3 -6 -7 -10 -8 -17 -17 -24 -25 -1.8 -3.0 3.8 3.0 -6 -5 -8 -7 -10 -9 -14 -13 -0.6 -0.4 3.4 2.5 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB/GTHB-3-040 Dimensions and Weights 516 Right-hand version with 90° direction of discharge shown 452 Fan shaft 50 329 8 263 ø9 33 Max. IEC132 30 303*) 338 543 744 ø 388 312 945*) 985 36*) 41 *) Distance between the anti-vibration mountings 249 30 Right-hand version (viewed from drive side) 507 30 600 507 764 653 507 469 363 239 38 121 1075 41 310 203 1130 90° 1041 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLB/HB-3-040: 41,0 Belt drive: 4,0 270° Outlet flange 329 - 149,5 ø10 15 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 4x 134,3 546 567 537 507 269 299 308 30 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB/GTHB-3-040 Belt-driven, single-inlet, backward-curved blades 3500 80 GTHBmax 3500 3000 Impeller diameter: 400 mm r/min η-korr GTHB-3-040 80 GTLB-3-040 81 3500 1 η,% 3000 75 3000 .997 GTLBmax 2800 2000 2500 60 2500 .991 2000 1000 2000 .981 40 Only the GTLB is available in the smoke extraction version. 80 L wA,dB 75 1000 r/min 200 85 90 95 1500 .959 100 1000 .903 100 50 0 1 qv 2000 0.1 3 m 3/s 2 4000 6000 8000 10000 m 3/h 1000 0.2 J = 0.24 kgm 2 0.5 P,kW 1500 1 1 2000 Acoustic Data 2 2 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 2500 2800 3000 3 4 4 6 3500 r/min 6 7 pd 10 ∆p 1 20 5 ∆ p 2 + pd 8 60 10 80 100 20 40 ∆p 3 Lwokt(s)=LWA+Kokt(s) 30 100 10 ∆p 4 160 40 60 80 60 70 Pa 20 40 60 Pa 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 1928 1929 – 3500 1 -1 -2 -3 2 -7 -5 -2 -5 -5 -8 -7 To inlet duct (2) 0 – 1928 1929 – 3500 2 -1 0 -4 -2 -10 -3 -2 -6 -4 To surroundings – the fan inlet and outlet ducted (3) 0 – 1928 1929 – 3500 -7 -10 -9 -13 -6 -10 -10 -9 To fan outlet (open-discharge fan) (4) 0 – 1928 1929 – 3500 -11 -16 -7 -8 0 -9 -6 -3 FIFLO 4249 GB 02.12 31 Pa 400 Pa 300 Correction, Kokt, dB Speed range Pa 40 r/min Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 250 20 Sound path (s) where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 200 200 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: Fläkt Woods Oy P M ,kW ∆p t ,Pa 1500 500 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -15 -12 -18 -17 0 0 6.3 4.4 -9 -6 -11 -8 -11 -15 -0.3 1.1 6.6 3.3 -10 -9 -14 -15 -23 -23 -33 -36 -6.2 -6.0 5.3 3.3 -5 -5 -8 -7 -15 -12 -18 -17 -0.8 -0.3 3.9 1.8 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLF-3-045 Dimensions and Weights 545 Right-hand version with 90° direction of discharge shown Fan shaft 55 488 359 10 293 ø9 38 Max. IEC160 35 338*) 378 621 824 ø 445 338 1080*) 1120 36*) 41 282 *) Distance between the anti-vibration mountings 30 Right-hand version (viewed from drive side) 569 30 685 569 858 718 569 525 396 257 41 133 1205 38 354 282 1252 90° 1161 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLF-3-045: 45,0 Belt drive: 5,0 270° Outlet flange 359 - 164,5 ø10 15 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 4x 149,8 608 629 599 569 299 329 338 32 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLF-3-045 Belt-driven, single-inlet, forward-curved blades 2000 r/min 1500 60 65 η,% 1400 Impeller diameter: 450 mm 60 1300 1200 1000 50 1100 1000 900 40 800 500 100 600 95 200 L wA,dB 85 90 100 GTLF-3-045 50 0.5 1 2 qv 4000 6000 4 m 3/s 3 8000 10000 14000 m /h 12000 P,kW 0.2 1 2 Acoustic Data A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 0.4 600 700 800 900 1000 1100 1200 1300 1400 1500 r/min J = 0.23 kgm 2 1 2 5 5 8 10 8 pd 50 ∆p 1 10 ∆ p 2 + pd ∆p 3 Lwokt(s)=LWA+Kokt(s) 100 20 50 30 100 10 ∆p 4 10 200 40 200 40 40 60 r/min 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 1010 1011 – 1500 1 1 3 2 -2 -4 -3 -5 -6 -5 -7 -7 To inlet duct (2) 0 – 1010 1011 – 1500 3 3 1 -2 -5 -8 -5 -6 -2 -2 To surroundings – the fan inlet and outlet ducted (3) 0 – 1010 1011 – 1500 -11 -12 -6 -9 -5 -8 -4 -9 To fan outlet (open-discharge fan) (4) 0 – 1010 1011 – 1500 -14 -15 -2 -3 -4 -6 -3 -5 Fläkt Woods Oy 100 80 80 100 Correction, Kokt, dB Speed range FIFLO 4249 GB 02.12 33 Pa 600 Pa 60 Sound path (s) Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 80 Pa 400 20 20 300 60 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: P M ,kW ∆p t ,Pa 700 Pa Pa LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -11 -10 -15 -14 0 0 6.9 6.2 -7 -6 -10 -9 -15 -13 1.0 1.2 7.9 7.3 -6 -7 -9 -8 -18 -18 -25 -26 -1.7 -2.9 3.3 2.2 -6 -5 -7 -7 -11 -10 -15 -14 -0.2 -0.3 3.5 2.7 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB/GTHB-3-045 Dimensions and Weights 545 Right-hand version with 90° direction of discharge shown Fan shaft 55 488 359 10 293 ø9 38 Max. IEC160 35 338*) 378 621 824 ø 445 338 1080*) 1120 36*) 41 *) Distance between the anti-vibration mountings 282 30 Right-hand version (viewed from drive side) 569 30 685 569 858 718 569 525 396 257 41 133 1205 38 354 282 1252 90° 1161 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLG/HB-3-045: 49,5 Belt drive: 5,0 270° Outlet flange 359 - 164,5 ø10 15 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 4x 149,8 608 629 599 569 299 329 338 34 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB/GTHB-3-045 Belt-driven, single-inlet, backward-curved blades 3500 80 GTHBmax 3200 3000 3000 81 80 r/min η-korr GTHB-3-045 GTLB-3-045 3200 1 η,% Impeller diameter: 450 mm 3000 .999 75 GTLBmax 2500 2000 2500 .995 60 2000 1000 2000 .987 ∆p t ,Pa 1500 Only the GTLB is available in the smoke extraction version. 40 500 1500 .972 1000 r/min 200 L wA,dB 80 85 95 90 100 1000 .93 100 50 0 1 qv 2000 0.2 2 4000 6000 8000 10000 0.5 1 1500 1 1.5 2 2000 P M ,kW P,kW J = 0.46 kgm 2 2 3 3 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 4 2500 4 6 6 3000 8 3200 r/min 8 10 10 pd 10 ∆p 1 20 5 40 10 ∆ p 2 + pd Lwokt(s)=LWA+Kokt(s) 40 60 80 100 20 30 100 150 40 60 200 100 500 Pa 400 10 20 40 60 80 Pa ∆p 4 10 20 40 60 80 Pa 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 964 965 – 1928 1929 – 3200 0 -2 -3 5 -1 -4 2 3 -4 -3 -3 -1 -6 -6 -6 -9 -9 -8 To inlet duct (2) 0 – 964 965 – 1928 1929 – 3200 4 2 -2 3 -1 -5 0 0 -6 -3 -3 -2 -4 -5 -4 To surroundings – the fan inlet and outlet ducted (3) 0 – 964 965 – 1928 1929 – 3200 -8 -10 -12 -5 -8 -14 -6 -6 -11 -8 -10 -8 To fan outlet (open-discharge fan) (4) 0 – 964 965 – 1928 1929 – 3200 -9 -13 -17 0 -6 -9 0 1 -6 -3 -3 -1 Correction, Kokt, dB Speed range FIFLO 4249 GB 02.12 Pa ∆p 3 r/min Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 80 300 Sound path (s) where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 12 250 300 350 Pa 200 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: Fläkt Woods Oy 14000 m 3/h 12000 1000 0.5 Acoustic Data 4 m 3/s 3 35 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -14 -14 -13 -18 -17 -16 0 0 0 8.2 6.4 4.1 -9 -8 -7 -12 -10 -9 -14 -13 -14 0.4 0.3 0.8 7.8 6.2 3.3 -11 -12 -10 -15 -16 -16 -22 -25 -24 -33 -36 -35 -6.1 -7.3 -6.4 6.1 5.8 3.1 -6 -6 -6 -9 -9 -8 -14 -14 -13 -18 -17 -16 -0.6 -0.5 -0.1 5.5 4.5 2.3 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLF-3-050 Dimensions and Weights 581 Right-hand version with 90° direction of discharge shown 533 Fan shaft 65 394 10 328 ø 12 38 Max. IEC160 35 383*) 433 657 912 ø 495 372 1200*) 1250 36*) 48 304 *) Distance between the anti-vibration mountings 30 Right-hand version (viewed from drive side) 638 30 722 638 950 801 638 580 449 276 40 109 1331 48 432 304 1388 90° 1298 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLF-3-050: 56,0 Belt drive: 5,0 270° Outlet flange 394 - 182 ø10 15 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 4 x 167 677 698 668 638 334 364 373 36 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLF-3-050 Belt-driven, single-inlet, forward-curved blades 2000 r/min 1300 Impeller diameter: 500 mm η,% 65 60 60 1200 50 1100 1000 1000 40 900 800 700 105 600 100 500 200 L wA,dB 85 400 90 95 100 GTLF-3-050 50 0.5 1 2 qv 4000 6000 P,kW 0.2 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 8000 1 10000 12000 14000 1 2 5 10 pd 50 ∆p 1 100 10 ∆ p 2 + pd ∆p 3 50 20 30 100 200 40 200 10 40 20 80 100 40 60 60 Sound path (s) r/min 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 1010 1011 – 1300 -2 -2 2 1 -2 -5 -3 -4 -6 -5 -7 -7 To inlet duct (2) 0 – 1010 1011 – 1300 1 0 -2 -3 -3 -8 -4 -3 -2 -2 To surroundings – the fan inlet and outlet ducted (3) 0 – 1010 1011 – 1300 -14 -15 -7 -8 -5 -9 -4 -8 To fan outlet (open-discharge fan) (4) 0 – 1010 1011 – 1300 -14 -14 -2 -3 -4 -7 -3 -4 80 80 FIFLO 4249 GB 02.12 37 Pa 100 Correction, Kokt, dB Speed range Pa 600 Pa 400 20 10 14 Pa 300 60 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: Fläkt Woods Oy 0.4 J = 0.32 kgm 2 10 11 ∆p 4 Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 18000 m 3/h 16000 5 Lwokt(s)=LWA+Kokt(s) where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 5 m 3/s 4 400 500 600 700 800 900 1000 1100 1200 1300 r/min 2 Acoustic Data 3 P M ,kW ∆p t ,Pa 500 Pa LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -11 -10 -15 -14 0 0 5.9 5.1 -7 -6 -9 -8 -15 -13 1.3 1.7 7.1 6.8 -6 -7 -9 -8 -18 -18 -25 -26 -1.7 -2.8 3.0 2.1 -6 -5 -7 -7 -11 -10 -15 -14 -0.2 -0.2 3.5 2.7 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB/GTHB-3-050 Dimensions and Weights 581 Right-hand version with 90° direction of discharge shown Fan shaft 65 533 394 10 328 ø 12 38 Max. IEC160 35 383*) 433 657 912 ø 495 372 1200*) 1250 36*) 48 304 *) Distance between the anti-vibration mountings 30 Right-hand version (viewed from drive side) 638 30 722 638 801 950 638 580 449 276 40 109 1331 48 432 304 1388 90° 1298 0° 270° Left-hand version (same dimensions as the right-hand version) 90° Weight (kg) GTLB/HB-3-050: Belt drive: 0° 270° Outlet flange 61,0 5,0 394 - 182 ø10 15 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 4 x 167 677 698 668 638 334 364 373 38 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB/GTHB-3-050 3500 80 GTHBmax 2800 2600 80 Impeller diameter: 500 mm r/min η-korr GTHB-3-050 GTLB-3-050 82 3000 2400 2800 1 η,% 2600 .999 75 2400 .998 2200 GTLBmax 2100 2000 2000 2200 .996 60 1800 2000 .994 1800 .992 1600 1000 1600 .988 1400 40 ∆p t ,Pa 1200 Only the GTLB is available in the smoke extraction version. 1200 .975 1000 L wA,dB 80 85 90 95 100 1000 .961 800 r/min 200 800 .938 100 50 Note: Max. speed of the smoke extraction version is 870 rpm. 0 1 qv 4000 2000 0.1 0.2 2 6000 3 8000 5 m 3/s 4 m 3/h 10000 12000 14000 16000 800 0.5 J = 0.70 kgm 2 1000 P,kW 1400 .983 500 1200 1 1 1400 1600 2 3 2000 2100 2200 4 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 2 1800 Acoustic Data 4 6 2400 2600 8 8 2800 r/min 10 ∆p 1 20 5 60 80 100 10 ∆ p 2 + pd 40 ∆p 3 Lwokt(s)=LWA+Kokt(s) 20 30 100 10 ∆p 4 160 200 40 60 200 500Pa 400 60 80 Pa 20 40 60 80 Pa 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 964 965 – 1928 1929 – 2800 -4 -4 -5 5 0 -4 2 3 -2 -5 -5 0 -5 -5 -6 -9 -9 -10 To inlet duct (2) 0 – 964 965 – 1928 1929 – 2800 4 1 -4 2 -2 -6 -1 1 -3 -3 -4 -1 -3 -4 -4 To surroundings – the fan inlet and outlet ducted (3) 0 – 964 965 – 1928 1929 – 2800 -12 -12 -14 -6 -7 -14 -7 -5 -9 -10 -12 -7 To fan outlet (open-discharge fan) (4) 0 – 964 965 – 1928 1929 – 2800 -12 -13 -17 1 -4 -8 1 2 -3 -5 -5 0 Correction, Kokt, dB Speed range FIFLO 4249 GB 02.12 39 Pa 40 r/min Fläkt Woods Oy 100 20 Sound path (s) Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 80 300 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 10 12 14 250 300 350 Pa 12 pd P M ,kW Belt-driven, single-inlet, backward-curved blades LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -14 -14 -14 -19 -17 -17 0 0 0 7.7 6.2 4.4 -10 -8 -8 -13 -11 -10 -17 -16 -14 0.4 0.4 0.9 7.4 5.8 3.3 -10 -11 -10 -15 -16 -18 -22 -25 -25 -34 -36 -36 -6.4 -7.2 -6.2 5.2 6.0 3.4 -5 -5 -6 -9 -9 -10 -14 -14 -14 -19 -17 -17 -0.5 -0.4 0 5.8 5.0 3.2 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLF-3-056 Dimensions and Weights 632 Right-hand version with 90° direction of discharge shown Fan shaft 65 585 435 12 368 ø 12 43 Max. IEC180 40 424*) 474 686 1030 ø 562 422 1314*) 1364 36*) 55 335 *) Distance between the anti-vibration mountings 30 Right-hand version (viewed from drive side) 715 30 790 715 1060 902 715 644 512 315 34 141 1493 37 467 90° 335 1561 1435 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLF-3-056: 84,0 Belt drive: 6,0 270° Outlet flange 109,3 ø10 15 435 186,3 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 4x 186,3 754 775 745 715 375 405 414 40 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLF-3-056 Belt-driven, single-inlet, forward-curved blades 2200 2000 r/min 1300 65 60 η,% 1200 Impeller diameter: 560 mm 60 1100 50 1000 1000 900 40 800 700 30 500 ∆p t ,Pa 600 500 200 L wA,dB 80 85 90 95 100 100 GTLF-3-056 50 1 2 5000 3 qv 4 10000 5 15000 6.5 m 3/s 6 m 3/h 20000 0.5 500 600 700 800 900 1000 1100 1200 1300 r/min 2 Acoustic Data A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 16 14 pd 40 ∆p 1 60 10 80 100 120 20 ∆ p 2 + pd Sound path (s) LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 30 100 ∆p 3 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: Fläkt Woods Oy 4 10 10 160 200 40 300 40 80 350 Pa 100 60 60 80 80 LWA LWA(s) 8 000 dB dB -11 -10 -16 -14 0 0 5.7 5.2 -6 -7 -10 -10 -15 -14 1.2 1.5 4.6 3.7 -6 -7 -9 -8 -18 -18 -26 -26 -1.7 -2.8 3.0 2.0 -6 -5 -7 -7 -11 -10 -16 -14 -0.2 -0.1 3.7 2.9 125 250 500 0 – 884 885 – 1200 -2 -2 1 1 -1 -4 -3 -4 -6 -5 -7 -7 To outlet duct (2) 0 – 884 885 – 1200 2 1 -3 -4 -4 -7 -5 -5 -2 -1 To surroundings – the fan inlet and outlet ducted (3) 0 – 884 885 – 1200 -14 -15 -7 -10 -5 -8 -4 -8 To fan outlet (open-discharge fan) (4) 0 – 884 885 – 1200 -13 -14 -3 -3 -2 -5 -3 -4 41 Pa LWA(s) – LWt(s) – Octave band, mid-frequency, Hz 63 FIFLO 4249 GB 02.12 r/min Pa 100 Correction, Kokt, dB Speed range Pa Pa 400 40 20 300 60 160 200 20 ∆p 4 Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 2 10 Lwokt(s)=LWA+Kokt(s) where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 1 J = 0.60 kgm 2 P M ,kW P,kW 1 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB/GTHB-3-056 Dimensions and Weights 632 Right-hand version with 90° direction of discharge shown 585 Fan shaft 65 435 12 368 ø 12 43 Max. IEC180 40 424*) 474 686 1030 ø 562 422 1314*) 1364 36*) 55 335 *) Distance between the anti-vibration mountings 30 Right-hand version (viewed from drive side) 715 30 790 715 1060 902 715 644 512 315 34 141 1493 37 467 90° 335 1561 1435 0° 270° Left-hand version (same dimensions as the right-hand version) 90° Weight (kg) GTLB/HB-3-056: Belt drive: 0° 270° Outlet flange 91,0 8,0 109,3 ø10 15 435 186,3 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 4x 186,3 754 775 745 715 375 405 414 42 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB/GTHB-3-056 Belt-driven, single-inlet, backward-curved blades 3500 GTHBmax 2500 2400 3000 80 82 η,% 80 r/min η-korr GTHB-3-056 GTLB-3-056 2500 1 2400 1 2200 Impeller diameter: 560 mm 75 GTLBmax 2000 2000 2200 .998 1800 2000 .997 60 1600 1800 .995 1400 1000 1600 .993 Only the GTLB is available in the smoke extraction version. 500 40 1000 r/min 1400 .989 100 L wA,dB 80 90 85 95 1200 .983 200 1000 .973 100 50 0.5 1 2000 2 qv 6000 4000 3 4 6 m 3/s 5 8000 10000 12000 14000 16000 18000 20000 m 3/h 0.5 1 1000 P,kW 1 1200 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 6 3 1600 3 4 2 1400 2 Acoustic Data J = 1.10 kgm 2 4 5 6 1800 2000 8 2200 10 2400 2500 r/min 10 20 ∆p 1 60 5 ∆ p 2 + pd Lwokt(s)=LWA+Kokt(s) 10 100 20 40 140 30 200 40 100 200 400 Pa ∆p 3 10 20 40 60 Pa ∆p 4 10 20 40 60 Pa r/min 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 964 965 – 1928 1929 – 2500 -5 -5 -6 4 -2 -5 1 2 -3 -5 -5 -1 -4 -4 -5 -9 -9 -9 To inlet duct (2) 0 – 964 965 – 1928 1929 – 2500 0 -2 -5 3 -3 -6 0 1 -5 -5 -6 -1 -3 -3 -4 To surroundings – the fan inlet and outlet ducted (3) 0 – 964 965 – 1928 1929 – 2500 -13 -13 -14 -5 -9 -12 -7 -5 -10 -10 -12 -8 To fan outlet (open-discharge fan) (4) 0 – 964 965 – 1928 1929 – 2500 -13 -14 -16 0 -6 -9 0 1 -4 -5 -5 -1 Fläkt Woods Oy 80 90 Pa 300 Sound path (s) Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 250 60 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 12 14 16 300Pa 14 pd Correction, Kokt, dB Speed range FIFLO 4249 GB 02.12 43 P M ,kW ∆p t ,Pa 1200 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -14 -14 -14 -18 -17 -17 0 0 0 7.0 5.4 3.7 -8 -8 -8 -12 -12 -11 -15 -15 -14 0.6 0.4 0.7 6.4 4.9 3.0 -9 -10 -11 -15 -16 -16 -22 -25 -25 -33 -36 -36 -5.9 -6.8 -6.8 5.1 5.1 3.5 -4 -4 -5 -9 -9 -9 -14 -14 -14 -18 -17 -17 -0.3 -0.2 0 5.0 4.1 2.7 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLF-3-063 Dimensions and Weights 674 Right-hand version with 90° direction of discharge shown 628 Fan shaft 65 477 14 409 ø 12 48,5 Max. IEC180 45 466*) 516 706 1149 ø 620 468 1395*) 1445 36*) 59 375 *) Distance between the anti-vibration mountings 50 Right-hand version (viewed from drive side) 801 30 845 801 1188 1000 801 722 566 350 41 199 1504 59 482 90° 375 1716 1539 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLF-3-063: 107,0 Belt drive: 6,0 270° Outlet flange 119,6 ø10 15 477 207,8 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 4x 207,8 840 861 831 801 417 447 456 44 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLF-3-063 Belt-driven, single-inlet, forward-curved blades 1800 r/min 1000 Impeller diameter: 630 mm 69 65 60 η,% 65 60 900 1000 800 700 500 90 500 85 400 200 L wA,dB 80 300 100 GTLF-3-063 50 1 P,kW 5000 5 15000 1 2 8 m 3/s 7 20000 m 3/h 25000 300 400 500 600 700 J = 0.90 kgm 2 2 800 Acoustic Data 4 900 1000 r/min A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 10 10 18 16 pd 40 ∆p 1 10 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: Sound path (s) LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 100 30 100 ∆p 3 10 160 200 50 60 40 200 300 20 ∆p 4 where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 60 20 ∆ p 2 + pd 40 Lwokt(s)=LWA+Kokt(s) Fläkt Woods Oy 3 qv 10000 P M ,kW ∆p t ,Pa 40 95 600 40 80 350 Pa 100 60 60 80 80 LWA LWA(s) 8 000 dB dB -11 -10 -16 -15 0 0 5.7 5.7 -6 -6 -10 -9 -16 -15 1.2 1.2 4.5 4.4 -6 -7 -9 -8 -18 -18 -26 -27 -1.8 -3 2.9 2.2 -6 -5 -7 -7 -11 -10 -16 -15 -0.1 -0.3 3.9 3.7 125 250 500 0 – 785 786 – 1000 -2 -1 1 2 -1 -4 -3 -5 -6 -5 -7 -7 To inlet duct (2) 0 – 785 786 – 1000 2 2 -4 -5 -4 -4 -5 -6 -2 -2 To surroundings – the fan inlet and outlet ducted (3) 0 – 785 786 – 1000 -14 -14 -7 -8 -6 -9 -4 -9 To fan outlet (open-discharge fan) (4) 0 – 785 786 – 1000 -10 -9 -2 -1 -2 -5 -3 -5 45 Pa LWA(s) – LWt(s) – Octave band, mid-frequency, Hz 63 FIFLO 4249 GB 02.12 r/min Pa 100 Correction, Kokt, dB Speed range Pa 600 Pa 400 40 20 300 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB/GTHB-3-063 Dimensions and Weights 674 Right-hand version with 90° direction of discharge shown 628 Fan shaft 65 477 14 409 ø 12 48,5 Max. IEC180 45 466*) 516 706 1149 ø 620 468 1395*) 1445 36*) 59 375 *) Distance between the anti-vibration mountings 50 Right-hand version (viewed from drive side) 801 30 845 801 1188 1000 801 722 566 350 41 199 1504 59 482 90° 375 1716 1539 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLB/HB-3-063: 115,0 Belt drive: 8,0 270° Outlet flange 119,6 ø10 15 477 207,8 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 4x 207,8 840 861 831 801 417 447 456 46 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB/GTHB-3-063 Belt-driven, single-inlet, backward-curved blades 3500 80 r/min η-korr GTHB-3-063 η,% GTLB-3-063 84 GTHBmax 2100 2000 3000 2100 1 2000 1 80 Impeller diameter: 630 mm 1800 75 2000 1800 .999 GTLBmax 1600 1600 .997 60 1400 1400 .995 1000 1200 1200 .992 40 Only the GTLB is available in the smoke extraction version. 1000 .986 500 800 L wA,dB 80 600 r/min 200 85 90 95 600 .956 100 50 0 1 2 3 qv 5000 0.2 4 10000 5 15000 6 P,kW Acoustic Data 0.5 J = 2.0 kgm 2 1000 2 2 1200 3 4 1400 6 8 1800 10 10 2000 2100 r/min 14 16 pd 10 ∆p 1 20 5 60 80 100 10 ∆ p 2 + pd 40 ∆p 3 15 20 30 100 10 ∆p 4 160 200 40 250 300 350 Pa 60 200 80 300 100 Pa 400 40 60 80 Pa 20 40 60 80 Pa Sound path (s) r/min 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 815 816 – 1631 1632 – 2100 -5 -6 -7 3 -4 -6 0 1 -5 -5 -5 -1 -4 -4 -5 -8 -8 -9 To inlet duct (2) 0 – 815 816 – 1631 1632 – 2100 -4 -5 -8 3 -4 -7 0 1 -5 -7 -8 -2 -3 -3 -3 To surroundings – the fan inlet and outlet ducted (3) 0 – 815 816 – 1631 1632 – 2100 -13 -14 -15 -6 -11 -13 -7 -7 -9 -10 -10 -8 To fan outlet (open-discharge fan) (4) 0 – 815 816 – 1631 1632 – 2100 -12 -13 -15 0 -7 -9 -1 0 -6 -5 -5 -1 Correction, Kokt, dB Speed range FIFLO 4249 GB 02.12 47 25 Pa 20 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: Fläkt Woods Oy 1 1 1600 Lwokt(s)=LWA+Kokt(s) Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] m 3/h 25000 600 4 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 8 m 3/s 7 20000 800 where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 800 .977 100 P M ,kW ∆p t ,Pa 1000 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -14 -14 -14 -17 -17 -17 0 0 0 6.3 4.5 3.1 -9 -9 -9 -11 -13 -12 -14 -14 -14 0.3 0 0.5 6.1 4.5 2.6 -9 -9 -11 -14 -14 -16 -22 -22 -25 -32 -32 -36 -5.7 -5.8 -6.7 4.6 3.5 3.5 -4 -4 -5 -8 -8 -9 -14 -14 -14 -17 -17 -17 -0.2 -0.2 -0.1 4.7 3.6 2.4 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLF-3-071 Dimensions and Weights 723 Right-hand version with 90° direction of discharge shown 678 526 Fan shaft 65 14 458 ø 12 48,5 Max. IEC180 45 525*) 585 723 1297 ø 710 529 1510*) 1560 36*) 59 427 *) Distance between the anti-vibration mountings 50 Right-hand version (viewed from drive side) 898 30 884 898 1331 1124 898 806 639 399 38 222 1619 59 546 427 1858 90° 1643 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLF-3-071: 134,0 Belt drive: 6,0 270° Outlet flange 132 ø10 15 526 232 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 4 x 232 937 958 928 898 466 496 505 48 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLF-3-071 Belt-driven, single-inlet, forward-curved blades 1800 69 r/min 850 Impeller diameter: 710 mm η,% 65 60 65 800 1000 60 700 50 600 40 ∆p t ,Pa 500 500 400 95 90 300 200 L wA,dB 85 100 GTLF-3-071 50 2 4 10000 qv 6 15000 10 m 3/s 8 20000 25000 35000 m 3/h 30000 0.5 P,kW J = 2.20 kgm 2 400 2 600 4 700 Acoustic Data 800 850 r/min A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 10 10 20 22 18 pd 40 ∆p 1 60 15 ∆ p 2 + pd 80 100 120 20 30 100 200 40 40 60 Sound path (s) r/min 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 558 559 – 850 -2 -2 -1 0 1 -1 -2 -3 -7 -5 -8 -8 To inlet duct (2) 0 – 558 559 – 850 1 1 -2 -3 -1 -4 -6 -5 -3 -2 To surroundings – the fan inlet and outlet ducted (3) 0 – 558 559 – 850 -14 -15 -6 -8 -4 -8 -3 -7 To fan outlet (open-discharge fan) (4) 0 – 558 559 – 850 -9 -10 -4 -3 0 -2 -2 -3 Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] Pa 500 80 80 FIFLO 4249 GB 02.12 49 Pa 100 Pa Correction, Kokt, dB Speed range Pa 100 Pa 60 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 80 400 40 20 300 60 300 20 ∆p 4 160 160 200 ∆p 3 Lwokt(s)=LWA+Kokt(s) Fläkt Woods Oy 2 500 P M ,kW 300 1 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -13 -12 -18 -16 0 0 5.7 5.4 -8 -7 -11 -10 -17 -16 0.3 1.0 5.4 4.4 -7 -7 -10 -9 -20 -20 -28 -28 -1.9 -3.0 3.7 2.5 -7 -5 -8 -8 -13 -12 -18 -16 -0.3 -0.2 4.4 3.8 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB/GTHB-3-071 Dimensions and Weights 723 Right-hand version with 90° direction of discharge shown 678 526 Fan shaft 65 14 458 ø 12 48,5 Max. IEC180 45 525*) 585 723 1297 ø 710 529 1510*) 1560 36*) 59 427 *) Distance between the anti-vibration mountings 50 Right-hand version (viewed from drive side) 898 30 884 898 1331 1124 898 806 639 399 38 222 1619 59 546 427 1858 90° 1643 0° 270° Left-hand version (same dimensions as the right-hand version) 90° 0° Weight (kg) GTLB/HB-3-071: 144,0 Belt drive: 10,0 270° Outlet flange 132 ø10 15 526 232 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 4 x 232 937 958 928 898 466 496 505 50 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB/GTHB-3-071 Belt-driven, single-inlet, backward-curved blades 3500 80 GTHBmax 1900 1800 3000 84 r/min η-korr GTHB-3-071 η,% GTLB-3-071 1900 1 1800 1 80 Impeller diameter: 710 mm 1600 75 2000 1600 .999 GTLBmax 1450 1400 1400 .998 60 1200 1000 1200 .996 1000 40 ∆p t ,Pa 1000 .992 Only the GTLB is available in the smoke extraction version. 800 500 L wA,dB 80 85 90 100 95 105 800 .987 600 r/min 200 600 .974 100 50 0 2 qv 5000 4 10000 6 15000 10 m 3/s 8 20000 25000 35000 m 3/h 30000 0.2 1 600 800 2 2 3 1000 4 4 Acoustic Data J = 4.5 kgm 2 1200 6 1400 1450 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 10 8 10 1600 15 1800 1900 r/min 20 22 pd 10 ∆p 1 20 5 ∆ p 2 + pd 20 60 80 100 10 20 40 ∆p 3 Lwokt(s)=LWA+Kokt(s) 30 160 200 40 100 10 ∆p 4 200 300 Pa 400 40 60 80 Pa 20 40 60 80 Pa r/min 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 815 816 – 1631 1632 – 1900 -5 -5 -6 2 -6 -6 -1 -1 -4 -4 -4 -2 -4 -3 -4 -9 -9 -9 To inlet duct (2) 0 – 815 816 – 1631 1632 – 1900 -3 -3 -5 2 -5 -6 -1 0 -5 -6 -7 -2 -5 -5 -5 To surroundings – the fan inlet and outlet ducted (3) 0 – 815 816 – 1631 1632 – 1900 -13 -13 -14 -6 -13 -13 -7 -7 -10 -9 -9 -9 To fan outlet (open-discharge fan) (4) 0 – 815 816 – 1631 1632 – 1900 -11 -11 -13 -1 -9 -9 -2 -2 -5 -4 -4 -2 Fläkt Woods Oy 100 Pa 20 Sound path (s) Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 80 Correction, Kokt, dB Speed range FIFLO 4249 GB 02.12 51 25 Pa 250 300 60 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: P M ,kW P,kW 1 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -14 -15 -14 -20 -20 -19 0 0 0 5.6 3.9 3.2 -9 -10 -9 -14 -14 -13 -19 -19 -18 -1.0 -1.3 -0.4 6.6 5.3 3.5 -9 -8 -10 -15 -15 -16 -22 -23 -25 -35 -35 -38 -5.7 -5.3 -6.7 4.7 3.2 3.2 -4 -3 -4 -9 -9 -9 -14 -15 -14 -20 -20 -19 -0.4 0 -0.1 4.3 2.8 2.4 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB/GTHB-3-080 Dimensions and Weights Right-hand version with 90° direction of discharge shown Fan shaft 1256 40 12 80 70 ø 806 ø90 86 525 8 43 40 Anti-vibration mountings GTLB: 820 GTHB: 840 GTLB: 770 GTHB: 810 45 40 M10 101 ø 40 h 8 124 151 1470 1510 ø 11,5 1007 872 ø 806 965 50 598 589 494 722 ø 15 633 1216 Right-hand version (viewed from drive side)40 1470 40 40 965 494 494 598 40 40 1555 1515 767 60 30 605 917 1096 550 60 30 1350 605 1096 40 30 60 2045 2210 1791 2000 90° 605 45 45 643 1301 45 1010 1791 2000 0° 270° Left-hand version (same dimensions as the right-hand version) 90° Weight (kg) GTLB/HB-3-080: 267,0 Belt drive: 12,0 0° 270° Outlet flange 212 ø10 15 613 153 212 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 5 x 212 1065 1095 1056 1015 533 573 583 52 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB/GTHB-3-080 3500 Belt-driven, single-inlet, backward-curved blades r/min 76 GTHBmax 1660 1600 3000 Impeller diameter: 800 mm 80 82 r/min η-korr GTHB-3-080 GTLB-3-080 η% 1660 1 1600 1 80 1500 1500 .999 75 1400 GTLBmax 1350 1300 2000 1400 .998 70 1300 .997 1200 60 1200 .996 1100 1100 .995 50 1000 1000 1000 .993 900 900 .99 ∆p t ,Pa 800 Only the GTLB is available in the smoke extraction version. L wA,dB 88 700 500 92 100 96 104 108 800 .986 700 .981 600 600 .973 200 100 2 4 qv 10000 6 8 20000 12 m 3/s 10 30000 40000 m 3/h 0.5 2 r/min 600 700 800 JL = 3.10 kgm 2 JH = 4.30 kgm2 2 4 900 1000 1100 Acoustic Data 1200 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 10 10 1300 1350 1400 1500 20 20 1600 1660 26 pd 30 ∆p 1 50 10 100 20 ∆ p 2 + pd 40 Lwokt(s)=LWA+Kokt(s) 30 40 100 50 200 70 80 400 Pa 10 20 40 60 Pa ∆p 4 10 20 40 60 Pa 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 815 816 – 1631 1632 – 1660 -4 -4 -4 0 -8 -6 -2 -4 -5 -3 -3 -3 -3 -3 -4 -10 -9 -7 To inlet duct (2) 0 – 815 816 – 1631 1632 – 1660 -2 -2 -3 0 -5 -5 -1 -2 -4 -5 -6 -4 -6 -7 -6 To surroundings – the fan inlet and outlet ducted (3) 0 – 815 816 – 1631 1632 – 1660 -11 -11 -10 -7 -16 -13 -9 -11 -12 -8 -9 -10 To fan outlet (open-discharge fan) (4) 0 – 815 816 – 1631 1632 – 1660 -10 -10 -10 -2 -10 -8 -2 -4 -5 -3 -3 -3 Correction, Kokt, dB Speed range FIFLO 4249 GB 02.12 Pa ∆p 3 r/min Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 60 300 Sound path (s) where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 30 Pa 200 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: Fläkt Woods Oy P M ,kW P,kW 1 53 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -15 -15 -14 -23 -23 -21 0 0 0 5.0 3.3 3.2 -11 -11 -9 -17 -17 -15 -24 -24 -23 -1.8 -2.7 -1.5 6.7 6.0 4.6 -8 -11 -9 -15 -14 -13 -23 -23 -22 -33 -33 -31 -5.1 -6.8 -5.9 3.9 3.2 2.9 -3 -3 -4 -10 -9 -7 -15 -15 -14 -23 -23 -21 0.1 0 0 4.1 2.5 2.4 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB/GTHB-3-090 Dimensions and Weights Right-hand version with 90° direction of discharge shown Fan shaft 1405 40 14 80 70 ø 911 40 ø90 85 587 9 48,5 Anti-vibration mountings GTLB: 900 GTHB: 980 GTLB: 831 GTHB: 879 45 40 M10 101 ø 45 h 8 978 124 151 1648 1688 ø 11,5 1130 ø 911 1080 50 670 651 557 809 ø 15 695 1366 Right-hand version (viewed from drive side) 40 1648 40 40 1080 557 557 670 40 40 1734 1693 45 30 854 60 605 1023 1246 614 60 30 1528 605 1246 40 30 60 2223 2390 1940 2150 90° 605 45 715 1454 45 1125 1940 2150 0° 270° Left-hand version (same dimensions as the right-hand version) 90° Weight (kg) GTLB/HB-3-090: 320,0 Belt drive: 21,0 0° 270° Outlet flange 236 ø10 15 675 165 236 19,5 15 19,5 15 ø10 4,5 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 5 x 236 1185 1218 1175 1138 595 632 642 54 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB/GTHB-3-090 3500 Belt-driven, single-inlet, backward-curved blades r/min 77 80 GTHBmax 1480 3000 82 η% 1400 1350 1300 Impeller diameter: 900 mm 2000 r/min η-korr GTHB-3-090 GTLB-3-090 1480 1 1400 1 80 1300 .999 75 GTLBmax 1200 70 1200 .998 1100 1100 .997 60 1000 1000 .996 900 1000 50 900 .994 800 800 .992 Only the GTLB is available in the smoke extraction version. 500 700 .989 600 95 90 L wA,dB 85 600 .983 105 100 500 .975 200 100 2 4 6 qv 10000 8 20000 10 30000 12 15 m 3/s 14 40000 50000 m 3/h 0.5 1 2 1 r/min 600 J L = 4.50 kgm 2 J H = 5.30 kgm 2 P,kW 700 2 4 800 P M ,kW ∆p t ,Pa 700 900 Acoustic Data A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 25 30 35 pd To outlet duct (1) 20 30 35 50 10 ∆ p 2 + pd LWA(s)=LWA+[LwA(s)–LWA] Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 30 ∆p 1 Sound path (s) where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 1200 1300 1350 1400 1480 20 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: 10 1100 15 Lwokt(s)=LWA+Kokt(s) Fläkt Woods Oy 1000 10 100 20 40 30 200 40 100 50 200 60 250 70 Pa 80 400 Pa 300 ∆p 3 10 20 40 60 Pa ∆p 4 10 20 40 60 Pa Correction, Kokt, dB Speed range r/min LWA LWA(s) 8 000 dB dB -15 -14 -20 -20 0 0 4.8 3.5 -11 -10 -17 -17 -23 -22 -1.8 -1.8 3.0 1.7 -8 -11 -14 -13 -23 -22 -30 -30 -5.2 -6.7 3.7 3.3 -3 -3 -9 -8 -15 -14 -20 -20 0 0.1 3.7 2.7 125 250 500 0 – 815 816 – 1480 -3 -4 -1 -6 -2 -3 -4 -4 -3 -3 -9 -8 To inlet duct (2) 0 – 815 816 – 1480 -3 -3 0 -4 -1 -2 -4 -5 -7 -6 To surroundings – the fan inlet and outlet ducted (3) 0 – 815 816 – 1480 -10 -11 -8 -14 -9 -10 -9 -10 To fan outlet (open-discharge fan) (4) 0 – 815 816 – 1480 -8 -9 -3 -8 -2 -3 -4 -4 55 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz 63 FIFLO 4249 GB 02.12 Pa 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB/GTHB-3-100 Dimensions and Weights Fan shaft 14 90 80 ø 911 Anti-vibration mountings GTLB: 1005 GTHB: 1005 GTLB: 955 GTHB: 955 9 45,8 50 Right-hand version with 90° direction of discharge shown ø90 45 85 670 M10 101 ø 45 h 8 1125 1267 1860 ø 911 1176 50 735 657 884 ø 11,5 124 151 ø 15 730 770 1541 Right-hand version (viewed from drive side) 657 657 1860 1176 735 1905 1905 45 780 575 30 1586 1170 929 729 30 1481 30 2116 45 30 1800 217 1234 575 2435 2280 2116 2280 2600 90° 635 30 45 1221 0° 270° Left-hand version (same dimensions as the right-hand version) 90° Weight (kg) GTLB/HB-3-100: 367,0 Belt drive: 34,0 0° 270° Outlet flange 227 770 270 227 27 50 6 x 220 1367 1267 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 ø12 670 56 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB/GTHB-3-100 r/min 77 80 GTHBmax 1360 1300 3000 Impeller diameter: 1000 mm 80 1200 1300 1 75 1200 .999 70 1100 .999 1000 .998 60 900 900 .997 50 800 1000 1360 1 η% 1100 GTLBmax 1030 1000 2000 r/min η-korr GTHB-3-100 GTLB-3-100 82.2 ∆p t ,Pa 700 Only the GTLB is available in the smoke extraction version. 700 .994 600 L wA,dB 86 500 500 94 90 600 .99 106 102 98 500 .985 400 .976 200 100 2 4 6 2 8 qv 10000 0.5 1 10 12 14 30000 m 3/h 2 JL = 8.40 kgm 2 JH=10.9 kgm2 600 P,kW 18 m 3/s 16 50000 r/min 500 4 700 800 10 Acoustic Data A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: LWA(s)=LWA+[LwA(s)–LWA] where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] Fläkt Woods Oy 10 900 1000 1030 1100 20 20 1200 30 30 1300 1360 40 45 pd 30 ∆p 1 5 ∆ p 2 + pd Lwokt(s)=LWA+Kokt(s) 40 50 10 100 20 40 200 30 40 100 50 Pa 60 200 70 80 Pa Pa 300 ∆p 3 10 20 40 60 Pa ∆p 4 10 20 40 60 Pa Correction, Kokt, dB Speed range Sound path (s) 800 .996 r/min P M ,kW Belt-driven, single-inlet, backward-curved blades LWA(s) – LWt(s) – Octave band, mid-frequency, Hz 63 125 250 500 1 000 2 000 4 000 LWA LWA(s) 8 000 dB dB To outlet duct (1) 0 – 815 816 – 1360 -1 -4 -1 -6 -3 -3 -4 -5 -4 -4 -7 -6 -13 -13 -20 -21 0 0 5.0 3.4 To inlet duct (2) 0 – 815 816 – 1360 -2 -3 0 -5 -2 -2 -3 -4 -5 -6 -11 -11 -17 -17 -23 -22 -1.0 -1.7 6.0 5.1 To surroundings – the fan inlet and outlet ducted (3) 0 – 815 816 – 1360 -8 -11 -7 -14 -10 -10 -9 -11 -9 -10 -12 -11 -21 -21 -30 -31 -5.3 -5.8 4.2 2.7 To fan outlet (open-discharge fan) (4) 0 – 815 816 – 1360 -5 -8 -2 -7 -3 -3 -4 -5 -4 -4 -7 -6 -13 -13 -20 -21 0 0 4.0 2.7 FIFLO 4249 GB 02.12 57 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB-3-112 Dimensions and Weights, motor in line with the fan Outlet flange Fan shaft 14 115 100 ø 1000 80 710 9 53,5 1120 2099 ø90 ø 15 7 x 150 1220 1120 Anti-vibration mountings 1489 45 810 M10 101 1049 65 710 ø1000 879 835 85 65 ø 50 h 8 1220 2099 4 x 150 85 1040 50 Right-hand version with 90° direction of discharge shown ø 15 ø 11,5 124 151 1884 120 45 770 810 Right-hand version (viewed from drive side) With motor IEC 132-180 1884 2099 1220 1884 835 835 610 2264 25 1350 1350 25 IEC 132 IEC 160 IEC 180 1385 1214 45 120 120 45 1654 1044 2264 IEC 132 IEC 160 IEC 180 2049 25 1450 775 25 1450 45 120 IEC 132 IEC 160 IEC 180 25 1350 2950 2750 1884 2099 1220 835 25 2750 With motor IEC 200–225 1884 1350 835 610 2264 120 45 1654 25 1044 1450 1450 25 2049 IEC 200 IEC 225 IEC 200 IEC 225 1385 1214 25 1550 1550 3150 2950 90° 0° 775 25 25 45 120 2264 45 120 IEC 200 IEC 225 1450 1450 25 2950 270° Left-hand version (same dimensions as the right-hand version) 90° 0° 270° Weight (kg) GTLB-3-112: 353,0 Base frame: 130,0 Belt drive: 40,0 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 58 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB-3-112 Dimensions and Weights, motor placed beside the fan Right-hand version with 90° direction of discharge shown Fan shaft Outlet flange 14 1040 9 53,5 ø 1000 4 x 150 85 80 85 50 115 100 710 65 ø 50 h 8 1220 2099 ø 15 7 x 150 1220 1120 Anti-vibration mountings 1120 ø90 1489 ø1000 45 879 835 ø 15 1049 2099 M10 101 810 ø 11,5 100 810 124 151 1884 65 710 20 1660 45 20 1700 Right-hand version (viewed from drive side) 2099 1884 1884 1220 610 835 835 2244 2244 2029 1634 30 912 912 30 30 1020 100 755 807 1020 30 90° 45 1024 45 100 100 45 1365 1194 0° 807 240 30 270° Left-hand version (same dimensions as the right-hand version) 90° 0° 270° Weight (kg) GTLB-3-112: 353,0 Base frame: 150,0 Belt drive: 40,0 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 59 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Notes Fläkt Woods Oy FIFLO 4249 GB 02.12 60 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB-3-112 Belt-driven, single-inlet, backward-curved blades 3000 Impeller diameter: 1120 mm 1100 1 85 η% 1000 2000 r/min η-korr GTLB-3-112 r/min 83 1100 1000 1 80 900 900 .999 70 800 800 .998 60 700 1000 700 .997 600 ∆p t ,Pa 600 .995 Only the GTLB is available in the smoke extraction version. 500 500 L wA,dB 88 92 40 100 96 500 .992 400 400 .987 200 100 2 6 10000 18 m 3/s 14 30000 m 3/h 50000 400 2 4 P,kW 500 J=18.2 kgm2 600 P M ,kW 1 10 qv 700 10 Acoustic Data A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 900 pd 30 ∆p 1 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 50 10 ∆ p 2 + pd Sound path (s) Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 1100 r/min 30 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 20 1000 20 Lwokt(s)=LWA+Kokt(s) Fläkt Woods Oy 800 10 100 20 40 30 30 35 300 Pa 200 40 100 50 200 60 70 80 90 Pa 400 Pa 300 ∆p 3 10 20 40 60 Pa ∆p 4 10 20 40 60 Pa Correction, Kokt, dB Speed range Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -14 -13 -14 -27 -24 -25 0 0 0 6,2 6,5 4,9 -7 -8 -8 -14 -13 -14 -27 -24 -25 0 0 0 6,2 6,5 4,9 -11 -10 -10 -12 -13 -13 -22 -21 -22 -37 -34 -35 -6,1 -5,4 -5,7 5,5 5,8 4,0 -5 -5 -5 -7 -8 -8 -14 -13 -14 -27 -24 -25 0 -0,1 0 4,8 5,6 4,4 63 125 250 500 0 – 400 401 – 800 801 – 1100 2 0 -4 -1 2 -2 -2 -1 0 -3 -3 -2 -5 -5 -5 -7 -8 -8 To inlet duct (2) 0 – 400 401 – 800 801 – 1100 2 0 -4 -1 2 -2 -2 -1 0 -3 -3 -2 -5 -5 -5 To surroundings – the fan inlet and outlet ducted (3) 0 – 400 401 – 800 801 – 1100 -5 -7 -11 -8 -4 -10 -9 -8 -7 -10 -8 -8 To fan outlet (open-discharge fan) (4) 0 – 400 401 – 800 801 – 1100 -2 -4 -8 -2 1 -3 -2 -1 0 -3 -3 -2 FIFLO 4249 GB 02.12 r/min 61 LWA(s) – LWt(s) – 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB-3-125 Dimensions and Weights, motor in line with the fan Outlet flange Fan shaft 14 115 100 ø 1120 80 800 9 53,5 986 1250 2357 ø90 ø 15 8 x 150 1350 1250 Anti-vibration mountings 1682 55 55 ø 50 h 8 1371 2357 5 x 150 55 1140 50 Right-hand version with 90° direction of discharge shown 55 800 ø1120 63 900 920 M12 ø 14,5 1179 ø 15 120 150 2099 120 63 860 900 Right-hand version (viewed from drive side) With motor IEC 132-180 2099 2357 1371 2099 920 920 675 2540 25 1450 1450 25 IEC 132 IEC 160 IEC 180 1554 1362 63 120 120 63 1865 1169 2540 IEC 132 IEC 160 IEC 180 2282 25 1575 858 25 1575 63 120 IEC 132 IEC 160 IEC 180 25 1450 3200 2950 2099 2357 1371 920 25 2950 With motor IEC 200–225 2099 1450 920 675 120 63 1865 25 1169 1575 1575 25 2540 IEC 200 IEC 225 IEC 250 2282 IEC 200 IEC 225 IEC 250 1554 1362 25 3200 90° 1675 1675 3400 0° 858 25 25 63 120 2540 63 120 IEC 200 IEC 225 IEC 250 1575 1575 3200 270° Left-hand version (same dimensions as the right-hand version) 90° 0° 270° Weight (kg) GTLB-3-125: 421,0 Base frame: 140,0 Belt drive: 40,0 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 62 Specifications are subject to alteration without notice 25 Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB-3-125 Dimensions and Weights, motor placed beside the fan Right-hand version with 90° direction of discharge shown Fan shaft Outlet flange 14 1140 9 53,5 ø 1120 5 x 150 55 80 55 50 115 100 800 55 ø 50 h 8 1371 2357 1350 1250 Anti-vibration mountings ø 15 8 x 150 1250 ø90 1682 ø1120 63 986 ø 15 1179 900 120 150 2099 2357 900 M12 ø 14,5 920 55 800 25 1755 63 120 25 1805 Right-hand version (viewed from drive side) With motor IEC 132-250 2357 2099 2099 1371 675 920 920 2540 2540 2282 1865 30 1020 1020 30 30 1149 120 858 907 1149 30 90° 63 1169 63 120 120 63 1554 1362 0° 907 255 30 270° Left-hand version (same dimensions as the right-hand version) 90° 0° 270° Weight (kg) GTLB-3-125: 421,0 Base frame: 190,0 Belt drive: 40,0 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 63 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Notes Fläkt Woods Oy FIFLO 4249 GB 02.12 64 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB-3-125 Belt-driven, single-inlet, backward-curved blades 3000 r/min 83 1000 Impeller diameter: 1250 mm 1000 1 η% 900 2000 r/min η-korr GTLB-3-125 85 900 1 80 800 800 .999 70 700 60 1000 700 .998 600 600 .997 ∆p t ,Pa 500 Only the GTLB is available in the smoke extraction version. 40 500 400 L wA,dB 88 92 96 500 .995 100 400 .992 200 100 2 6 10 qv 20000 14 18 40000 24 m 3/s 22 60000 m 3/h 80000 1 500 5 10 600 800 20 900 30 pd 30 ∆p 1 Sound path (s) LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 35 50 10 ∆ p 2 + pd where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: 30 1000 r/min 40 Lwokt(s)=LWA+Kokt(s) Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 700 20 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 5 J = 36.6 kgm 2 10 Acoustic Data Fläkt Woods Oy 400 P M ,kW P,kW 2 100 20 40 30 100 200 40 50 300 60 200 80 300 100 Pa Pa 400 ∆p 3 10 20 40 60 80 Pa ∆p 4 10 20 40 60 80 Pa Correction, Kokt, dB Speed range r/min LWA LWA(s) 8 000 dB dB -14 -13 -14 -27 -24 -25 0 0 0 6,2 6,5 4,9 -7 -8 -8 -14 -13 -14 -27 -24 -25 0 0 0 6,2 6,5 4,9 -11 -10 -10 -12 -13 -13 -22 -21 -22 -37 -34 -35 -6,1 -5,4 -5,7 5,5 5,8 4,0 -5 -5 -5 -7 -8 -8 -14 -13 -14 -27 -24 -25 0 -0,1 0 4,8 5,6 4,4 125 250 500 0 – 400 401 – 800 801 – 1000 2 0 -4 -1 2 -2 -2 -1 0 -3 -3 -2 -5 -5 -5 -7 -8 -8 To inlet duct (2) 0 – 400 401 – 800 801 – 1000 2 0 -4 -1 2 -2 -2 -1 0 -3 -3 -2 -5 -5 -5 To surroundings – the fan inlet and outlet ducted (3) 0 – 400 401 – 800 801 – 1000 -5 -7 -11 -8 -4 -10 -9 -8 -7 -10 -8 -8 To fan outlet (open-discharge fan) (4) 0 – 400 401 – 800 801 – 1000 -2 -4 -8 -2 1 -3 -2 -1 0 -3 -3 -2 65 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz 63 FIFLO 4249 GB 02.12 40 45 Pa 1 000 2 000 4 000 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB-3-140 Dimensions and Weights, motor in line with the fan Outlet flange Fan shaft 18 130 100 ø 1250 80 900 11 64 ø 15 9 x 150 1500 1400 Anti-vibration mountings 1400 2660 ø90 1910 105 55 ø 60 h 8 1550 2660 5 x 150 105 1220 50 Right-hand version with 90° direction of discharge shown 55 900 ø1250 63 1110 1000 1010 M12 ø 14,5 1330 ø 15 120 150 2340 140 63 965 1000 Right-hand version (viewed from drive side) With motor IEC 132-180 2340 2660 1550 2340 1010 1010 750 2863 30 1570 1570 30 IEC 132 IEC 160 IEC 180 1752 1533 63 140 140 63 2113 1313 2863 IEC 132 IEC 160 IEC 180 2543 30 1720 953 30 1720 63 140 IEC 132 IEC 160 IEC 180 30 1570 3500 3200 2340 2660 1550 1010 30 3200 With motor IEC 200–225 2340 1570 1010 750 140 63 2113 30 1313 1720 1720 30 2863 IEC 200 IEC 225 IEC 250 2543 IEC 200 IEC 225 IEC 250 1752 1533 30 3500 90° 1820 1820 3700 0° 953 30 30 63 140 2863 63 140 IEC 200 IEC 225 IEC 250 1720 1720 3500 270° Left-hand version (same dimensions as the right-hand version) 90° 0° 270° Weight (kg) GTLB-3-140: 555,0 Base frame: 180,0 Belt drive: 50,0 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 66 Specifications are subject to alteration without notice 30 Centrimaster GT-3 CATALOGUE Dimensions and Weights – GTLB-3-140 Dimensions and Weights, motor placed beside the fan Right-hand version with 90° direction of discharge shown Fan shaft Outlet flange 18 1220 11 64 ø 1250 5 x 150 105 80 105 50 130 100 900 55 ø 60 h 8 1550 2660 ø 15 9 x 150 1500 1400 Anti-vibration mountings 1400 ø90 1910 ø1250 63 1110 ø 15 1330 140 1000 120 150 2340 2660 1000 M12 ø 14,5 1010 55 900 30 1875 63 30 1935 Right-hand version (viewed from drive side) 2660 2340 2340 1550 750 1010 1010 2863 2863 2543 2113 30 1140 1140 30 30 1300 140 953 1021 1300 30 90° 63 1313 63 140 140 63 1753 1533 0° 1021 268 30 270° Left-hand version (same dimensions as the right-hand version) 90° 0° 270° Weight (kg) GTLB-3-140: 555,0 Base frame: 240,0 Belt drive: 50,0 Motor data: See separate motor list. Fläkt Woods Oy FIFLO 4249 GB 02.12 67 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Notes Fläkt Woods Oy FIFLO 4249 GB 02.12 68 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Fan Charts – Acoustic Data – GTLB-3-140 3000 Belt-driven, single-inlet, backward-curved blades r/min 83 900 r/min η-korr GTLB-3-140 85 900 1 η% Impeller diameter: 1400 mm 800 2000 80 800 1 700 70 700 .999 600 60 1000 600 .998 ∆p t ,Pa 500 Only the GTLB is available in the smoke extraction version. 40 400 500 500 .997 L wA,dB 85 90 95 100 400 .995 200 100 Note: Max. speed of the smoke extraction version is 870 rpm. 2 6 10 qv 20000 14 40000 18 22 60000 30 m 3/s 26 80000 100000 m 3/h 2 P,kW 6 J = 61.4 kgm 2 10 500 10 20 600 Acoustic Data 700 20 A-weighted sound power levels LWA on the outlet side of a fan with the inlet and outlet ducted are specified in the chart. Correction figures can be read from the adjacent table. The following formula is used for breaking down the sound each octave band and each sound path: 30 800 30 40 40 900 50 r/min 60 60 pd 30 ∆p 1 5 ∆ p 2 + pd Lwokt(s)=LWA+Kokt(s) 50 10 100 20 40 30 40 100 50 70 80 400 Pa 300 10 20 40 60 Pa ∆p 4 10 20 40 60 Pa 63 125 250 500 LWA(s)=LWA+[LwA(s)–LWA] To outlet duct (1) 0 – 400 401 – 800 801 – 900 2 0 -4 -1 2 -2 -2 -1 0 -3 -3 -2 -5 -5 -5 -7 -8 -8 To inlet duct (2) 0 – 400 401 – 800 801 – 900 2 0 -4 -1 2 -2 -2 -1 0 -3 -3 -2 -5 -5 -5 To surroundings – the fan inlet and outlet ducted (3) 0 – 400 401 – 800 801 – 900 -5 -7 -11 -8 -4 -10 -9 -8 -7 -10 -8 -8 To fan outlet (open-discharge fan) (4) 0 – 400 401 – 800 801 – 900 -1 -3 -7 -2 1 -3 -2 -1 0 -3 -3 -2 Correction, Kokt, dB Speed range FIFLO 4249 GB 02.12 Pa ∆p 3 r/min Fläkt Woods Oy 60 200 Sound path (s) Lwt(s)=LWA(s)+[Lwt(s)–LWA(s)] 70 Pa 200 where Kokt can be obtained from the table. The following formula can be used for calculating the A-weighted sound power level on each sound path: where the correction figure LwA(s) – LwA can be obtained from the table. The table also includes correction figure Lwt(s) – LwA(s) that can be used for obtaining the total sound power level on each sound path: 69 P M ,kW 400 4 LWA(s) – LWt(s) – Octave band, mid-frequency, Hz LWA LWA(s) 8 000 dB dB -14 -13 -14 -27 -24 -25 0 0 0 6,2 6,5 4,9 -7 -8 -8 -14 -13 -14 -27 -24 -25 0 0 0 6,2 6,5 4,9 -11 -10 -10 -12 -13 -13 -22 -21 -22 -37 -34 -35 -5 -5 -5 -7 -8 -8 -14 -13 -14 -27 -24 -25 1 000 2 000 4 000 -6,1 -5,4 -5,7 0 0 0 5,5 5,8 4,0 5,0 5,6 4,4 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Motor Data – Single-speed Motors, 50 Hz 2 poles = 3000 r/min Size designation IEC ABB Motors Rated output, Speed, Ordering code APAL- kW r/min At rated output Current at 400 V, ca A 1) lst 2) l Mst M Mmax M Efficiency, η% Power factors, cos ϕ Weight, kg 71A 71B 80A M2VA 71A M2VA 71B M2VA 80A 2-90037-c-d 2-90055-c-d 2-90075-c-d 0,37 0,55 0,75 2840 2830 2870 1,05 1,39 1,8 5,5 5,7 6,2 3,8 3,6 2,9 3,9 3,7 3,6 77,1 79,2 81,2 0,77 0,78 0,75 5,5 6,5 9 80B 90S 90L M2VA 80B M2AA 90S M2AA 90L 2-90110-c-d 2-90150-c-d 2-90220-c-d 1,1 1,5 2,2 2850 2870 2870 2,5 3,35 4,55 6,1 5,5 7 2,3 2,4 2,7 3,5 3,0 3,0 82,2 80,1 80,8 0,78 0,82 0,86 11 13 16 100L 112 M 132 SM M2AA 100L M2AA 112 M M2AA 132 SA 2-90300-c-d 2-00400-c-d 2-00550-c-d 3 4 5,5 2900 2850 2855 5,95 7,4 10,5 7,5 7,5 7,8 2,7 2,8 3,2 3,6 3 3,4 86 86 86 0,88 0,91 0,88 21 25 37 132 S 160 M 160 M M2AA 132 SB M2AA 160 MA M2AA 160 M 2-00750-c-d 2-01100-c-d 2-01500-c-d 7,5 11 15 2855 2930 2920 13,9 20 26,5 8,5 6,3 6,6 3,4 1,9 2,3 3,6 2,5 2,5 87 91,2 91,7 0,90 0,88 0,90 42 73 84 160 L 180 M 200 ML M2AA 160 L M2AA 180 M M2AA 200 MLA 2-01850-c-d 2-02200-c-d 2-03000-c-d 18,5 22 30 2920 2930 2955 32 38,5 53 7,3 7,2 7,3 2,6 2,5 2,4 2,7 2,7 3,1 92,4 92,8 93,2 0,91 0,89 0,88 94 119 175 200 ML 225 SM 250 SM M2AA 200 MLB M2AA 225 SMB M2AA 250 SMA 2-03700-c-d 2-04500-c-d 2-05500-c-d 37 45 55 2950 2960 2970 64 79 95 7,3 7,3 7,5 2,5 2,5 2 3,2 2,8 3 93,6 93,9 94,4 0,89 0,88 0,89 200 235 285 280 S 280 SM 315 S M2CA 280 SA M2CA 280 SMA M2CA 315 SA 2-07500-c-d 2-09000-c-d 2-11000-c-d 75 90 110 2977 2975 2982 131 152 194 7,4 7,2 7,6 2 2,1 2 2,9 2,7 3 94,9 95,3 95,5 0,88 0,90 0,86 480 545 695 315 SM 315 M M2CA 315 SMA M2CA 315 MB 2-13200-c-d 2-16000-c-d 132 160 2982 2981 228 269 7,4 7,5 2,2 2,3 3 3 95,7 96,1 0,88 0,89 770 840 1) Correction factors The current values in the tables are applicable to motors wound for 400 V. All motors can be used for voltages between 380 and 420 V. Motors with voltage code c=1 can be connected in delta to operate in the range of 220–240 V. Motors with voltage code c=2 can be connected in star to operate in the range of 660–690 V. The correction factors on the current in the range of 400 V will then be: 220–240 V = 1.73 and 660–690 V = 0.58. Code suffix for voltage (c) 1 = 220–240 V delta/380–420 V star The motors can also be wound for 500 V, and the voltage code is then c=5. The correction factor on the current at 400 V is then 0.8. 5 = 500 V star (sizes 71–100) 500 V delta (sizes 112–315) The speeds, efficiencies and power factors are applicable at 230, 400, 690 and 500 V. 2) Temperature sensors in the stator winding, code suffix (d) 0 = without 1 = with bimetal temperature contacts 2 = with thermistor lst = Ratio of motor starting current to full-load current. l Fläkt Woods Oy FIFLO 4249 GB 02.12 2 = 380–420 V delta/660–690 V star 70 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Motor Data – Single-speed Motors, 50 Hz 4 poles = 1500 r/min Size designation IEC ABB Motors Rated output, Speed, Ordering code APAL- kW r/min At rated output Current at 400 V, ca A 1) lst 2) l Mst M Mmax M Efficiency, η% Power factors, cos ϕ Weight, kg 71A 71B 80A M2VA 71A M2VA 71B M2VA 80A 4-90025-c-d 4-90037-c-d 4-90055-c-d 0,25 0,37 0,55 1410 1420 1390 0,78 1,05 1,55 4,3 4,4 4,6 2,7 2,6 2,6 2,9 2,8 2,9 70,4 74,6 75,3 0,71 0,69 0,71 5,5 6,5 9 80B 90S 90L M2VA 80B M2AA 90S M2AA 90L 4-90075-c-d 4-90110-c-d 4-90150-c-d 0,75 1,1 1,5 1400 1410 1420 2,15 2,59 3,45 4,7 5 5 3,5 2,2 2,4 3,9 2,7 2,9 78,2 77,5 80,3 0,66 0,81 0,79 10,5 13 16 100LA 100LB 112 M M2AA100 LA M2AA100 LB M2AA 112 M 4-90220-c-d 4-90300-c-d 4-00400-c-d 2,2 3 4 1430 1430 1435 4,8 6,48 8,6 5,5 5,5 7 2,4 2,5 2,9 2,9 2,9 3,1 83 85 85 0,81 0,81 0,80 21 24 27 132 S 132 M 160 M M2AA 132 S M2AA 132 M M2AA 160 M 4-00550-c-d 4-00750-c-d 4-01100-c-d 5,5 7,5 11 1450 1450 1460 11,1 14,8 21,5 7,3 7,9 6,7 2,2 2,5 2,9 3 3,2 2,8 87 88 90,3 0,83 0,83 0,81 40 48 75 160 L 180 M 180 L M2AA 160 L M2AA 180 M M2AA 180 L 4-01500-c-d 4-01850-c-d 4-02200-c-d 15 18,5 22 1455 1470 1470 28,5 35 41 6,8 7 7 3 3,1 2,9 2,8 2,7 2,8 91,1 92,3 92,4 0,84 0,84 0,83 94 124 141 200 ML 225 SM 225 SM M2AA 200 MLA M2AA 225 SMA M2AA 225 SMB 4-03000-c-d 4-03700-c-d 4-04500-c-d 30 37 45 1475 1480 1480 56 68 83 6,7 6,6 6,7 2,6 2,4 2,7 2,8 2,5 2,6 92,9 93,6 94,2 0,83 0,84 0,83 180 215 230 250 SM 280 S 280 SM M2AA 250 SMA M2CA 280 SA M2CA 280 SMA 4-05500-c-d 4-07500-c-d 4-09000-c-d 55 75 90 1480 1483 1484 98 137 163 7,5 6,9 7,6 2,3 2,2 2,5 2,8 2,8 2,9 94,6 94,6 95 0,86 0,84 0,85 275 445 490 315 S 315 SM 315 M M2CA 315 SA M2CA 315 SMA M2CA 315 MB 4-11000-c-d 4-13200-c-d 4-16000-c-d 110 132 160 1487 1486 1486 198 238 282 6,5 7,3 7 2,1 2,2 2,4 2,6 2,7 2,7 95,4 95,6 96 0,85 0,85 0,86 675 730 850 1) Correction factors The current values in the tables are applicable to motors wound for 400 V. All motors can be used for voltages between 380 and 420 V. Motors with voltage code c=1 can be connected in delta to operate in the range of 220–240 V. Motors with voltage code c=2 can be connected in star to operate in the range of 660–690 V. The correction factors on the current in the range of 400 V will then be: 220–240 V = 1.73 and 660–690 V = 0.58. The motors can also be wound for 500 V, and the voltage code is then c=5. The correction factor on the current at 400 V is then 0.8 . Code suffix for voltage (c) 1 = 220–240 V delat/380–420 V star 2 = 380–420 V delta/660–690 V star 5 = 500 V star (sizes 71–100) 500 V delta (sizes 112–315) Temperature sensors in the stator winding, code suffix (d) 0 = without 1 = with bimetal temperature contacts 2 = with thermistor The speeds, efficiencies and power factors are applicable at 230, 400, 690 and 500 V. 2) lst = Ratio of motor starting current to full-load current. l Fläkt Woods Oy FIFLO 4249 GB 02.12 71 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Motor Data – Single-speed Motors, 50 Hz 6 poles = 1000 r/min Size designation IEC ABB Motors Rated output, Speed, Ordering code APAL- kW r/min At rated output Current at 400 V, ca A 1) lst 2) l Mst M Mmax M Efficiency, η% Power factors, cos ϕ Weight, kg 71A 71B 80A M2VA 71A M2VA 71B M2VA 80A 6-90018-c-d 6-90025-c-d 6-90037-c-d 0,18 0,25 0,37 920 920 915 0,65 0,86 1,15 2,9 3,2 3,8 2,1 2,5 3,1 2,2 2,7 3,4 61,1 64,9 72,9 0,69 0,64 0,65 80B 90S 90L M2VA 80B M2AA 90S M2AA 90L 6-90055-c-d 6-90075-c-d 6-90110-c-d 0,55 0,75 1,1 900 930 930 1,72 2,36 3,25 3,4 4 4 2,9 1,9 1,9 3,1 2,3 2,3 73,3 71,5 74,4 0,64 0,67 0,69 10 13 16 100L 112 M 132 S M2AA 100L M2AA 112 M M2AA 132 S 6-90150-c-d 6-00220-c-d 6-00300-c-d 1,5 2,2 3 950 940 960 3,92 5,4 6,9 4,5 5,6 6,1 1,9 2,1 2,4 2,3 2,7 2,6 80 80,5 84,5 0,71 0,74 0,75 23 27 39 132 M 132 M 160 M M2AA 132 MA M2AA 132 MB M2AA 160 M 6-00400-c-d 6-00550-c-d 6-00750-c-d 4 5,5 7,5 960 955 970 8,7 11,9 15,4 7,1 6,9 6,7 2,6 2,8 2 2,8 2,8 2,8 85,5 86 89,3 0,78 0,78 0,79 46 54 88 160 L 180 L 200 ML M2AA 160 L M2AA 180 L M2AA 200 MLA 6-01100-c-d 6-01500-c-d 6-01850-c-d 11 15 18,5 970 970 985 23 31 36 7,1 7 7 2,2 2,1 2,5 2,9 3 2,7 89,8 90,8 91,1 0,78 0,78 0,81 102 151 165 200 ML 225 SM 250 SM M2AA 200 MLB M2AA 225 SMB M2AA 250 SMA 6-02200-c-d 6-03000-c-d 6-03700-c-d 22 30 37 980 985 985 43 56 69 7,2 6,6 7,3 2,5 2,5 2,8 2,7 2,7 2,8 91,7 92,8 93,7 0,81 0,83 0,83 185 225 280 280 S 280 SM 315 S M2CA 280 SA M2CA 280 SMA M2CA 315 SA 6-04500-c-d 6-05500-c-d 6-07500-c-d 45 55 75 990 989 990 85 102 143 7 7 6,8 2,6 2,7 2,2 2,6 2,6 2,6 94,2 94,5 94,7 0,82 0,83 0,81 440 475 630 315 SM 315 M M2CA 315 SMA M2CA 315 MB 6-09000-c-d 6-11000-c-d 90 110 989 988 163 198 7 6,8 2,3 2,4 2,5 2,5 95,2 95,3 0,84 0,84 720 805 1) Correction factors The current values in the tables are applicable to motors wound for 400 V. All motors can be used for voltages between 380 and 420 V. Motors with voltage code c=1 can be connected in delta to operate in the range of 220–240 V. Motors with voltage code c=2 can be connected in star to operate in the range of 660–690 V. The correction factors on the current in the range of 400 V will then be: 220–240 V = 1.73 and 660–690 V = 0.58. The motors can also be wound for 500 V, and the voltage code is then c=5. The correction factor on the current at 400 V is then 0.8. The speeds, efficiencies and power factors are applicable at 230, 400, 690 and 500 V. 2) 5,5 6,5 9 Code suffix for voltage (c) 1 = 220–240 V delta/380–420 V star 2 = 380–420 V delta/660–690 V star 5 = 500 V star (sizes 71–100) 500 V delta (sizes 112–315) Temperature sensors in the stator winding, code suffix (d) 0 = without 1 = with bimetal temperature contacts 2 = with thermistor lst = Ratio of motor starting current to full-load current. l Fläkt Woods Oy FIFLO 4249 GB 02.12 72 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Motor Data – Single-speed Motors, 50 Hz 8 poles = 750 r/min Size designation IEC ABB Motors Rated output, Speed, Ordering code APAL- kW r/min At rated output Current at 400 V, ca A 1) lst 2) l Mst M Mmax M Efficiency, η% Power factors, cos ϕ Weight, kg 80 A 80 B 90 S M2VA 80A M2VA 80B M2AA 90S 8-90018-c-d 8-90025-c-d 8-90037-c-d 0,18 0,25 0,37 700 680 700 0,85 0,95 1,6 3,1 3,1 3 3,2 2,9 1,9 3,6 3,1 2,4 59,9 70,7 61,5 0,53 0,56 0,56 10 10,5 13 90 L 100 L 100 L M2AA 90L M2AA 100LA M2AA 100LB 8-90055-c-d 8-90075-c-d 8-90110-c-d 0,55 0,75 1,1 690 700 700 2,35 2,55 3,35 3 3,5 3,5 1,7 2,1 2,1 2,1 2,7 2,7 62,9 72 73 0,57 0,59 0,64 16,5 20 22 112 M 132 S 132 M M2AA 112 M M2AA 132 S M2AA 132 M 8-00150-c-d 8-00220-c-d 8-00300-c-d 1,5 2,2 3 695 720 720 4,5 5,9 7,8 4,1 5,3 5,5 1,9 1,9 2,4 2,4 2,5 2,6 75 81 82 0,65 0,67 0,68 28 46 53 160 M 160 M 160 L M2AA 160 MA M2AA 160 M M2AA 160 L 8-00400-c-d 8-00550-c-d 8-00750-c-d 4 5,5 7,5 715 710 715 10 13,4 18,1 5,2 5,4 5,4 2,1 2,4 2,4 2,4 2,6 2,8 84 85 86 0,69 0,70 0,70 75 88 118 180 L 200 ML 225 SM M2AA 180 L M2AA 200 MLA M2AA 225 SMA 8-01100-c-d 8-01500-c-d 8-01850-c-d 11 15 18,5 720 740 730 23,5 29 37 5,9 7,4 6,2 2,4 1,8 1,9 2,6 3 2,7 89 91,1 91,1 0,76 0,82 0,79 147 175 210 225 SM 250 SM 280 S M2AA 225 SMB M2AA 250 SMA M2CA 280 SA 8-02200-c-d 8-03000-c-d 8-03700-c-d 22 30 37 730 735 741 45 59 74 6 6,9 6,8 1,9 1,9 1,6 2,7 2,9 2,7 91,5 92,8 93 0,77 0,79 0,78 225 280 460 280 SM 315 S 315 SM M2CA 280 SMA M2CA 315 SA M2CA 315 SMA 8-04500-c-d 8-05500-c-d 8-07500-c-d 45 55 75 741 741 740 90 107 142 7,1 7,1 7,1 1,8 1,8 1,8 2,8 2,8 2,8 93,5 94 94,5 0,78 0,80 0,81 500 630 715 315 M M2CA 315 MB 8-09000-c-d 90 740 169 7,3 1,9 2,8 94,7 0,82 800 1) Correction factors The current values in the tables are applicable to motors wound for 400 V. All motors can be used for voltages between 380 and 420 V. Code suffix for voltage (c) 1 = 220–240 V delta/380–420 V star Motors with voltage code c=1 can be connected in delta to operate in the range of 220–240 V. Motors with voltage code c=2 can be connected in star to operate in the range of 660–690 V. The correction factors on the current in the range of 400 V will then be: 220–240 V = 1.73 and 660–690 V = 0.58. 2 = 380–420 V delta/660–690 V star The motors can also be wound for 500 V, and the voltage code is then c=5. The correction factor on the current at 400 V is then 0.8. Temperature sensors in the stator winding, code suffix (d) 0 = without 1 = with bimetal temperature contacts 2 = with thermistor The speeds, efficiencies and power factors are applicable at 230, 400, 690 and 500 V. 2) lst = Ratio of motor starting current to full-load current. l Fläkt Woods Oy FIFLO 4249 GB 02.12 5 = 500 V star (sizes 71–100) 500 V delta (sizes 112–315) 73 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Motor Data – Two-speed Motors, 50 Hz 2/4 poles = 3000/1500 r/min One stator winding (Dahlander wound) Size designation IEC ABB Motors No. of Ordering code motor ARAL-2poles Rated output, Speed, kW r/min At rated output Current at 400 V, ca A 1) lst 2) l Mst M Mmax M Efficiency, η% Power factors, cos ϕ Weight, kg 71 M2VA 71 B 90055-c-d 2 4 0,55 0,12 2700 1470 1,3 0,75 3,8 3,4 1,4 2,2 1,5 2,3 67 55 0,91 0,42 6,5 80 M2VA 80 A 90075-c-d 2 4 0,75 0,15 2850 1430 1,8 0,65 4,9 3,9 2,2 2,4 2,3 2,5 73 52 0,83 0,65 9 80 M2VA 80 B 90110-c-d 2 4 1,1 0,25 2840 1430 2,6 0,9 4,9 3,9 2,2 2,2 2,3 2,3 73 60 0,84 0,67 11 90 S M2AA 90 S 90150-c-d 2 4 1,5 0,33 2860 1460 3,3 1,1 5,2 3,9 1,8 1,1 2,4 2,1 77 66 0,87 0,67 13 90 L M2AA 90 L 90220-c-d 2 4 2,2 0,45 2860 1460 4,6 1,4 5,9 4,4 2,1 1,2 2,6 2,3 80 73 0,88 0,65 16 100 L M2AA 100 LB 90350-c-d 2 4 3,5 0,7 2880 1470 7 2 6,2 4,8 2,1 1,2 2,6 3 80 77 0,91 0,65 25 112 M M2AA 112 M 00451-c-d 2 4 4,5 1 2875 1450 8,4 2,4 7 6 1,8 1,9 2,3 2,8 83 80 0,93 0,76 32 132 S M2AA 132 S 00620-c-d 2 4 6,2 1,3 2880 1455 11,8 3,5 7 6,5 2 2,6 2,6 3,3 84 80 0,91 0,67 42 132 M M2AA 132 M 00830-c-d 2 4 8,3 1,7 2875 1455 15,4 4,2 7,4 6,6 2,5 2,7 2,7 3,3 84 82 0,93 0,71 56 160 M M2AA 160MA 01000-c-d 2 4 10 2 2910 1465 19 4,8 5,9 6,1 1,5 2,4 2,3 2,8 85 83,5 0,89 0,73 73 160 M M2AA 160 M 01600-c-d 2 4 16 3,2 2915 1465 28,5 7 6,6 6,3 1,8 2,5 2,4 2,8 87,5 86,5 0,92 0,76 94 160 L M2AA 160 L 01950-c-d 2 4 19,5 4,5 2930 1465 36 9,7 7,6 6,4 2,3 2,5 2,9 2,8 89 88 0,89 0,77 100 180 M M2AA 180 M 02150-c-d 2 4 21,5 4,7 2935 1465 38 10 7 5,3 2,1 2,1 2,6 2,3 90 88 0,91 0,77 137 180 L M2AA 180 L 02600-c-d 2 4 26 5,2 2940 1470 47 11 6,9 5,8 2,3 2,4 2,6 2,4 90,5 89,5 0,89 0,75 151 200 ML M2AA 200 MLA 03200-c-d 2 4 32 8 2940 1465 58 16 7,1 6,2 2 2 2,5 2,2 90 89 0,89 0,85 180 200 ML M2AA 200 MLB 03900-c-d 2 4 39 10 2950 1475 69 19 7,4 6,2 2 2 2,6 2,3 91,5 91 0,89 0,85 205 200 ML M2AA 200 MLC 04200-c-d 2 4 42 11 2950 1470 75 23 7,7 5,6 2,2 2,1 3 2,5 92,5 91 0,89 0,77 205 225 SM M2AA 225 SMB 04500-c-d 2 4 45 13 2955 1475 76 25 7,4 5,3 2 2 2,6 2,1 93 91,5 0,92 0,82 235 225 SM M2AA 225 SMC 05500-c-d 2 4 55 15 2955 1475 94 29 7,3 5,4 2 2 2,6 2,2 93,5 92,5 0,91 0,82 260 250 SM M2AA 250 SMB 07500-c-d 2 4 75 25 2955 1475 125 48 8,9 5,5 2,3 2 3,1 2,2 94,5 93 0,92 0,82 330 Code suffix for voltage (c) 1) Correction factors Correction factors for current at other voltages: 230 V = 1.74 ; 500 V = 0.80 The speeds, efficiencies and power factors are applicable at 230, 400 and 500 V. l 2) st = Ratio of motor starting current to full-load current l Fläkt Woods Oy FIFLO 4249 GB 02.12 V (sizes 71–132) 1 = 220–230 230 V (sizes 160–250) V (sizes 112–132) 2 = 380–400 400 V (sizes 160–315) V (sizes 71–100) 4 = 400–415 415 V (sizes 160–315) 5 = 500 V 74 (sizes 71–315) Temperature sensors in the stator winding, code suffix (d) 0 = without 1 = with bimetal temperature contacts 2 = with thermistor Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Motor Data – Two-speed Motors, 50 Hz 4/6 poles = 1500/1000 r/min Two separate windings Size designation IEC ABB Motors No. of Ordering code motor ATAL-4poles Rated output, Speed, kW r/min At rated output Current at 400 V, ca A 1) lst 2) l Mst M Mmax M Efficiency, η% Power factors, cos ϕ Weight, kg 71 M2VA 71 B 90030-c-d 4 6 0,3 0,1 1350 900 0,9 0,6 2,8 2 1 1,05 1,1 1,15 54 30 0,86 0,79 6,5 80 M2VA 80 A 90045-c-d 4 6 0,45 0,15 1390 945 1,2 0,7 3,2 3 1,6 1,5 1,7 1,6 65 42 0,85 0,75 10 80 M2VA 80 B 90075-c-d 4 6 0,75 0,22 1400 955 1,9 0,9 3,3 3,2 1,7 1,6 1,8 1,7 67 48 0,86 0,74 10,5 90 S M2AA 90 S 90100-c-d 4 6 1 0,3 1400 940 2,5 1,2 4,3 2,6 1,8 1 2,2 1,7 73 53 0,83 0,7 13 90 L M2AA 90 L 90150-c-d 4 6 1,5 0,45 1400 930 3,5 1,6 4,3 2,9 1,7 1 2,1 1,8 72 52 0,84 0,73 16 100 L M2AA 100 LA 90200-c-d 4 6 2 0,6 1430 960 4,5 2 5 3,3 1,8 1 2,4 1,9 77 62 0,85 0,72 20 100 L M2AA 100 LB 90250-c-d 4 6 2,5 0,8 1430 960 5,5 2,5 5,6 3,5 2 1,1 2,5 2 79 68 0,84 0,71 23 112 M M2AA 112 M 00300-c-d 4 6 3 1 1445 975 6,3 3,1 6 4 1,3 1 2,3 2,2 82 67 0,84 0,68 33 132 S M2AA 132 S 00450-c-d 4 6 4,5 1,5 1460 985 9,2 5,1 6,5 4,2 1,5 1 2,3 2,2 83 67 0,85 0,64 48 132 M M2AA 132 M 00600-c-d 4 6 6 2 1460 980 12 5,6 7,1 4,5 1,8 1,3 2,5 2 84 71 0,86 0,73 59 160 M M2AA 160 M 01050-c-d 4 6 10,5 3,5 1460 965 21 8,6 6,4 4,1 2 1,3 2,5 1,7 87 75,5 0,84 0,78 94 160 L M2AA 160 L 01450-c-d 4 6 14,5 4,5 1460 970 28 11 6,9 4,6 2,2 1,5 2,6 1,9 88,5 77 0,85 0,76 117 180 M M2AA 180 M 01601-c-d 4 6 16 5 1470 980 31 12,5 6,3 4,6 1,9 1,5 2,5 2 89 78 0,83 0,73 137 180 L M2AA 180 L 02001-c-d 4 6 20 6,5 1470 980 39 16 7,2 5 2,4 1,8 2,7 2 90 79,5 0,83 0,74 161 200 ML M2AA 200 MLA 02300-c-d 4 6 23 7,2 1475 985 43 15 7,7 7,8 1,6 1,9 2,8 2,9 89,5 84 0,88 0,87 175 200 ML M2AA 200 MLB 03000-c-d 4 6 30 9 1470 985 54 18 7,7 7,9 1,6 1,7 2,7 2,5 90 83,5 0,90 0,89 200 225 SM M2AA 225 SMB 03400-c-d 4 6 34 11 1470 985 60 21 7,7 6,7 1,5 1,3 2,7 2,3 91 85 0,91 0,89 225 225 SM M2AA 225 SMC 04200-c-d 4 6 42 14 1475 985 75 27 8,4 6,8 1,7 1,4 3 2,3 91,5 89 0,89 0,89 255 250 SM M2AA 250 SMB 06300-c-d 4 6 63 18,5 1475 985 110 40 7,5 7,3 2,4 3 2,7 2,6 93,5 87 0,89 0,79 335 280 SM M2CA 280 SMA 07700-c-d 4 6 77 25 1486 991 144 54 7,6 7,7 2,4 3,2 2,9 2,7 93,9 89,3 0,83 0,76 490 280 M M2CA 280 MB 09000-c-d 4 6 90 28 1485 991 161 58 7,4 7,7 2,3 3,2 2,7 2,8 94,2 89,8 0,86 0,78 550 315 SM M2CA 315 SMA 11000-c-d 4 6 110 32 1489 992 199 67 6,6 6,5 1,9 2,8 2,6 2,9 95,2 91,2 0,85 0,78 730 315 M M2CA 315 MB 12500-c-d 4 6 125 37 1488 992 219 75 6,6 6,4 1,9 2,9 2,4 2,8 95,5 92,2 0,86 0,79 850 315 L M2CA 315 LA 15000-c-d 4 6 150 44 1488 991 260 88 6,6 6,4 1,9 3 2,4 2,7 95,7 92,6 0,87 0,79 970 Code suffix for voltage (c) 1) Correction factors Correction factors for current at other voltages: 230 V = 1.74 ; 500 V = 0.80 The speeds, efficiencies and power factors are applicable at 230, 400 and 500 V. l 2) st = Ratio of motor starting current to full-load current l Fläkt Woods Oy FIFLO 4249 GB 02.12 V (sizes 71–132) 1 = 220–230 230 V (sizes 160–250) V (sizes 112–132) 2 = 380–400 400 V (sizes 160–315) Temperature sensors in the stator winding, code suffix (d) V (sizes 71–100) 4 = 400–415 415 V (sizes 160–315) 0 = without 1 = with bimetal temperature contacts 2 = with thermistor 5 = 500 V (sizes 71–315) 75 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Motor Data – Two-speed Motors, 50 Hz 4/8 poles = 1500/750 r/min One stator winding (Dahlander-connection) Size designation IEC ABB Motors No. of Ordering code motor ARAL-4poles 71 M2VA 71 B 90037-c-d 80 M2VA 80 A 90055-c-d 80 M2VA 80 B 90075-c-d 90 S M2AA 90 S 90110-c-d 90 L M2AA 90 L 90170-c-d 100 L M2AA 100 LA 90230-c-d 100 L M2AA 100 LB 90280-c-d 112 M M2AA 112 M 00350-c-d 132 S M2AA 132 S 00500-c-d 132 M M2AA 132 M 00680-c-d 160 M M2AA 160 M 01050-c-d 160 L M2AA 160 L 01550-c-d 180 M M2AA 180 M 01700-c-d 180 L M2AA 180 L 02200-c-d 200 ML M2AA 200 MLA 02900-c-d 200 ML M2AA 200 MLB 03300-c-d 225 SM M2AA 225 SMB 04200-c-d 225 SM M2AA 225 SMC 05000-c-d 250 SM M2AA 250 SMB 06000-c-d 280 S M2CA 280 SA 06500-c-d 280 SM M2CA 280 SMA 08000-c-d 280 M M2CA 280 MB 09000-c-d 315 SM M2CA 315 SMA 11000-c-d 315 M M2CA 315 MB 13200-c-d 315 L M2CA 315 LA 16000-c-d 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 4 8 Rated output, Speed, kW r/min 0,37 0,09 0,55 0,11 0,75 0,2 1,1 0,26 1,7 0,35 2,3 0,5 2,8 0,6 3,5 0,7 5 1 6,8 1,4 10,5 2,2 15,5 2,7 17 3,4 22 4,4 29 6,5 33 8 42 10 50 11 60 15 65 15 80 20 90 23 110 22 132 26 160 32 1360 700 1410 690 1410 690 1410 700 1390 700 1415 715 1430 720 1430 720 1450 725 1460 730 1460 735 1460 735 1470 730 1475 735 1470 730 1475 730 1480 740 1465 735 1475 735 1484 743 1486 743 1486 742 1487 744 1486 746 1486 743 1) Correction factors Correction factors for current at other voltages: 230 V = 1.74 ; 500 V = 0.80 The speeds, efficiencies and power factors are applicable at 230, 400 and 500 V. l 2) st = Ratio of motor starting current to full-load current l At rated output Current at 400 V, ca A 1,1 0,48 1,7 0,6 2,1 1 2,8 1,2 4,0 1,6 5,2 1,9 6,4 2,2 7 2,5 9,9 3,3 13,7 5,1 21 7,4 30 9,5 33 11 43 15 54 17 61 21 85 27 91 28 104 34 121 38 150 50 164 56 197 56 235 65 283 80 FIFLO 4249 GB 02.12 lst 2) l 3,1 1,7 3,6 2,4 3,7 2,4 4,2 2,4 4,5 2,5 4,6 2,7 5,2 3 6,8 4,4 6,4 3,6 7,6 3,6 6,9 3,7 6,9 3,9 5,8 4,3 6,7 3,9 6,9 4,2 7,8 4,2 7,8 5 7,3 4,7 7,9 4,7 7,5 5,3 8,5 5,4 8,8 5,4 6,8 4,9 6,8 4,8 7 4,8 Mst M 1,3 1,8 1,9 1,6 2 1,6 1, 8 1,2 2,2 1,5 1,8 1,2 2 1,2 1,6 1,7 1,5 1 2 1,4 2,2 1,5 2,2 1,7 1,7 1,2 2 1,7 2,2 1,9 2,6 1,9 2,5 2,2 2,3 2 2,6 2,1 2,7 2,8 3,3 2,9 3,6 2,8 1,9 2,1 2 2 2,1 2,1 Mmax M 1,4 1,9 2 1,7 2,1 1,7 2,3 1,9 2,6 2,1 2,4 1,9 2,6 2,2 2,5 2,7 2,3 2 2,8 2,7 2,7 2,3 2,6 2,6 2,3 1,9 2,6 2,3 2,4 1,9 2,6 1,8 3 2,3 2,5 2 2,7 2 2,9 2,3 3,4 2,6 3,5 2,6 2,6 2,5 2,6 2,4 2,7 2,5 Efficiency, η% Power factors, cos ϕ Weight, 58 19 62 40 69 46 73 53 74 57 76 63 81 68 81 71 83 74 85 73 87,5 79 88,5 79,5 88,5 78 89,5 79 90,5 86 91,5 86,5 92 89,5 92,5 89,5 93 90 93,2 90 93,8 91,5 94,1 91,8 94,6 92,5 94,9 93 95,2 93,4 0,84 0,52 0,74 0,65 0,76 0,64 0,80 0,63 0,82 0,57 0,84 0,6 0,82 0,58 0,89 0,58 0,87 0,59 0,84 0,55 0,84 0,54 0,85 0,51 0,85 0,56 0,83 0,53 0,86 0,64 0,86 0,64 0,78 0,61 0,87 0,65 0,86 0,70 0,84 0,63 0,83 0,63 0,85 0,64 0,85 0,62 0,86 0,64 0,86 0,64 6,5 kg 9 10,5 13 16 20 23 32 48 59 94 117 137 161 180 205 265 265 335 445 490 550 730 850 970 Delkod för spänning (c) V (sizes 71–132) 1 = 220–230 230 V (sizes 160–250) V (sizes 112–132) 2 = 380–400 400 V (sizes 160–315) Temperature sensors in the stator winding, code suffix (d) V (sizes 71–100) 4 = 400–415 415 V (sizes 160–315) 0 = without 1 = with bimetal temperature contacts 2 = with thermistor 5 = 500 V Fläkt Woods Oy 1) 76 (sizes 71–315) Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Accessories Plummer block with grease nipple GTLZ-06-3-ccc-d-0 Plummer block with grease nipple for the GTHB-3 (for size 040–071) GTLZ-09-3-ccc-d-0 Plummer block with grease nipple for the GTLB and GTLF (for sizes 025–071) d = 1 for right-hand version d = 2 for left-hand version The type GTLZ-06 and -09 Plummer block with grease nipple is mounted on a welded, compact frame with bearing bracket. Single-row, deep-groove ball bearings designed to be secured to the shaft by means of a tapered adapter sleeve are used in GTLZ-06 and -09 plummer blocks. If the fan is supplied with a flat belt drive, it should be equipped with the GTLZ-06/09. Fläkt Woods Oy FIFLO 4249 GB 02.12 77 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Accessories Flexible connections, inlet Protective screen, inlet GTLZ-11-3-ccc-1-0 Normal version, max. +80 °C GTLZ-13-3-ccc-1-0 Protective screen GTLZ-12-3-ccc-1-0 Smoke extraction version, max. +400 °C/2 hours Fläkt Woods Oy FIFLO 4249 GB 02.12 78 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Accessories Flexible connections, outlet Protective screen, outlet GTLZ-21-3-ccc-1-0 Normal version, max. +80 °C GTLZ-23-3-ccc-1-0 Protective screen, outlet GTLZ-22-3-ccc-1-0 Smoke extraction version, max. +400 °C/2 hours Counterflange, outlet Dimension sketch GTLZ-24-3-ccc-1-0 Counterflange B out Z X A out A2 A1 A in YxW L B in B1 B2 Size A in A out A1 A2 B in B out B1 B2 Z X Y W n D L 025 031 040 045 050 056 063 071 080 090 100 112 125 140 322 404 507 569 638 715 801 898 1015 1138 1267 1120 1250 1400 382 465 567 629 698 775 861 958 1095 1218 1367 1220 1350 1500 352 434 537 599 668 745 831 928 1056 1175 - 362 444 546 530 677 754 840 937 1065 1185 1320 1180 1310 1460 179 217 269 299 334 375 417 466 533 595 670 710 800 /900 239 277 329 359 394 435 477 526 613 675 770 810 900 1000 209 247 299 329 364 405 447 496 573 632 - 219 257 308 338 373 414 456 505 583 642 723 770 860 960 – – 149,5 164,5 182,0 109,3 119,6 132,0 212,0 236,0 227,0 150 150 150 – – – – – 186,3 207,8 232,0 153,0 165,0 270,0 300,0 450,0 450,0 2 2 4 4 4 4 4 4 5 5 6 7 8 9 176,0 217,0 134,3 149,8 167,0 186,3 207,8 232,0 212,0 236,0 220,0 150,0 150,0 150,0 6 6 12 12 12 14 14 14 16 16 18 20 24 24 10 10 10 10 10 10 10 10 10 10 10 15 15 15 115 115 115 150 150 150 150 150 145 145 150 150 150 150 Fläkt Woods Oy FIFLO 4249 GB 02.12 79 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Accessories Inspection cover Anti-vibration mountings GTLZ-32-3-ccc-d-0 Inspection cover Mounted on the back plate of the fan. Made of galvanised sheet steel. d = location on fan casing, 0 – 4, see illustration GTLZ-42-3-ccc-d-0 Anti-vibration mountings, rubber GT-3-025–071 d = 1 GTLB and GTLF ( 4 pc.) d = 2 GTHB (4 pc.) GT-3-080–100 d = 1 with motor IEC 100–132 (4 pc.) d = 2 with motor IEC 160–225 (6 pc.) 0 1 GT-3-112–140 d = 1 ( 6 pc.) 2 3 4 Drain GTLZ-34-3-ccc-d-0 Drain Mounted on the back plate of the fan. Made of galvanised sheet steel. d = location on fan casing, 0 – 4, see illustration 0 1 2 3 4 Note! The position of the inspection cover and drain depends on the discharge direction. Recommended positions are: GT…-3-bbb-c-d1-00 (0°) GTLZ-32-3-ccc-4-0 GTLZ-34-3-ccc-2-0 GT…-3-bbb-c-d3-00 (90°) GTLZ-32-3-ccc-1-0 GTLZ-34-3-ccc-4-0 GT…-3-bbb-c-d7-00 (270°) GTLZ-32-3-ccc-3-0 GTLZ-34-3-ccc-0-0 Fläkt Woods Oy FIFLO 4249 GB 02.12 80 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Accessories Flow Measurement Device Flow Measurement Device with manometer GTLZ-50-3-ccc-1-0 Flow measurement device for the GTLF GTLZ-53-3-ccc-1-0 Flow measurement device with manometer for the GTLF GTLZ-51-3-ccc-1-0 Flow measurement device for the GTLB, (not for sizes 112–140) GTLZ-54-3-ccc-1-0 Flow measurement device with manometer for the GTLB, (not for sizes 112–140) GTLZ-52-3-ccc-1-0 Flow measurement device for the GTHB GTLZ-55-3-ccc-1-0 Flow measurement device with manometer for the GTHB GTLZ-50, 51, 52 Flow measurement devices The flow measurement device is used for measuring the air flow in type GT fans. This is done by measuring the differential pressure in the device. The flow measurement device should be mounted in the fan inlet. The air flow is calculated as a function of coefficient k and the differential pressure reading ∆pm in the following manner: 1 q=— x k där q ∆pm k GTLZ-53, 54, 55 Flow measurement devices The flow measurement device is supplied with a manometer as well. The supply includes flow measuring device, manometer with scale and mounting bracket for the measuring device and hoses. For a technical specification, see the GTLZ-50, 51, 52 on the preceding page. pm 3 = air flow (m /s) = differential pressure reading (Pa) = coefficient unique to the fan selected The air flow that corresponds to the differential pressure reading can most easily be read with a manometer whose scale is graduated in accordance with the function above for a specific fan. On request, detailed charts can be supplied. The accuracy of the readings is ±10 %. If the flow measurement device is recalibrated at the site (for instance in an air handling unit), an accuracy of ±5 % can be achieved. Fläkt Woods Oy FIFLO 4249 GB 02.12 81 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Accessories Painted finish GTLZ-60-3-ccc-d-0 Painted finish, inner and outer surfaces d = 1 Epoxy powder coated and baked. 60 µm, colour: AM 8043, dark grey, M2 d = 2 Epoxy powder coated and baked. 100 µm, colour: AM 8043, dark grey, M3 d = 3 Wet-painted finish in three layers. 250 µm, colour: SSG28, light grey d =1 60 µm thick painted finish The fan casing, impeller and bearing bracket as well as accessories are coated with 60 mm thick epoxy powder and baked. The colour is AM 8043, dark grey. All bolts and nuts must be made of stainless steel. Painting process: – Alkali degreasing – Iron phosphate pre-treatment – Flushing with +40 °C water – Drying at 150 °C – Powder painting, 60 µm coat in one layer – Drying at 215 °C Motor cover GTLZ-77-3-ccc-d-0 Motor cover, made of galvanised steel. d = motor size (IEC) For fan sizes 025–071 1 = 071–100 2 = 112–132 3 = 160–180 Epoxy powder is well suited for coating objects that are subject to mechanical and chemical stress. It is an excellent rust-inhibitor and can withstand acids, alkaline solutions, greases and solvents. For fan sizes 080–140 4 = 100–160 5 = 180–250 d =2 100 µm thick painted finish; meets the provisions for Environmental Class M3. The fan casing, impeller and bearing bracket as well as accessories are coated with 100 µm thick epoxy powder and baked. The colour is AM 8043, dark grey. All bolts and nuts must be made of stainless steel. The coating process and epoxy powder are the same as in version d = 1; the coat is 100 µm thick in one layer. d = 3 250 µm wet painted finish in three coats. The fan casing and bearing bracket as well as accessories are painted with 250 µm thick epoxy in 3 layers. The colour is SSG28, light grey. The impeller is coated with 100 µm thick epoxy powder and baked. The colour is AM 8043, dark grey. All bolts and nuts must be made of stainless steel. Fläkt Woods Oy FIFLO 4249 GB 02.12 82 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Ordering Codes Centrifugal fan GTLB-a-bbb-c-dd-ee GTHB-a-bbb-c-dd-ee GTLF -a-bbb-c-dd-ee Plummer block with grease nipple GTLZ-06-3-ccc-d-0 for GTHB (for sizes 040–071) LB = centrifugal fan with backward curved blades (Sizes 025–140) HB =centrifugal fan with backward curved blades (Sizes 040–100) LF = centrifugal fan with forward curved blades (Sizes 025–071) Fan size (ccc) Fan type (a) 3 = single-inlet fan for a belt drive Plummer block with grease nipple GTLZ-09-3-ccc-d-0 for GTLB and GTLF (for sizes 025–071) Delivery version (d) 1 for right-hand version 2 for left-hand version Size (bbb) 025, 031,040, 045, 050, 056, 063, 071, 080, 090, 100, 112, 125, 140 Fan size (ccc) Version (c) 1 = normal version 6 = smoke extraction version (only GTLB and GTLF) 8 = spark-proof version Delivery version (d) 1 for right-hand version 2 for left-hand version Version and direction of discharge (dd) First d: 1 = right-hand version 2 = left-hand version Flexible connection, inlet Normal version, max. +80 °C Second d: 1 = 0º 3 = 90º 7 = 270º Motor location and generation (ee) First e: 0 = motor behind fan First e: 1 = motor alongside the fan (sizes 112-140) Second e: 0 = first generation Belt drive for GTLF-3 GTRF-3-bbb-1-dddd Belt drive for GTLB/GTHB-3 GTRB-3-bbb-1-dddd Fan size (ccc) Flexible connection, inlet Smoke extraction version, max. +400 °C Protective screen, inlet Fan speed, r/min (dddd) (If a two-speed motor is used, specify the higher speed.) APAL-a-bbbbb-c-d ARAL-a-bbbbb-c-d ATAL-a-bbbbb-c-d Flexible connection, outlet Normal version, max. +80 °C GTLZ-21-3-ccc-1-0 Fan size (ccc) Flexible connection, outlet Smoke extraction version, max. +400 °C Note: Due to generation change of motors the first digit “b” is 9 instead of 0 in motor sizes IEC 071–100. Accessories GTLZ-aa-b-ccc-d-e (aa) Type of accessory (b) 3 = Accessory for the GT..-3 (ccc) Fan size (d) 1 = to be supplied with fan (specify d = 0 if you are placing an order for individual accessories only). See the ordering code as well. (e) Generation digit. FIFLO 4249 GB 02.12 GTLZ-13-3-ccc-1-0 Fan size (ccc) See tabels on pages 70–76 Select the number of motor poles as follows: Fan speed < 459 r/min = 6-pole motor Fan speed 460-2344 r/min = 4-pole motor Fan speed > 2345 r/min = 2-pole motor Fläkt Woods Oy GTLZ-12-3-ccc-1-0 Fan size (ccc) Fan size (bbb) Motor GTLZ-11-3-ccc-1-0 GTLZ-22-3-ccc-1-0 Fan size (ccc) Protective screen, outlet GTLZ-23-3-ccc-1-0 Fan size (ccc) 83 Specifications are subject to alteration without notice Centrimaster GT-3 CATALOGUE Ordering Codes Accessories Counterflange, outlet Accessories Anti-vibration mountings GTLZ-24-3-ccc-1-0 Fan size (ccc) Fan size (ccc) Inspection cover Version (d) 1 = for GTLB and GTLF 2 = for GTHB GTLZ-32-3-ccc-d-0 Fan size (ccc) GTLZ-42-3-ccc-d-0 Flow measurement device for GTLF Location, se illustration (d) d= 0 1 2 3 1 4 GTLZ-50-3-ccc-1-0 Fan size (ccc) 0 Flow measurement device for GTLB (not for sizes 112–140) GTLZ-51-3-ccc-1-0 Fan size (ccc) 2 Flow measurement device for GTHB 3 4 GTLZ-52-3-ccc-1-0 Fan size (ccc) Drain Flow measurement device with manometer GTLF GTLZ-34-3-ccc-d-0 GTLZ-53-3-ccc-1-0 Fan size (ccc) Fan size (ccc) Location, se illustration (d) d= 0 1 2 3 1 4 0 2 Flow measurement device with manometer GTLB (not for sizes 112–140) Fan size (ccc) GTLZ-54-3-ccc-1-0 Flow measurement device with manometer GTHB GTLZ-55-3-ccc-1-0 Fan size (ccc) Painted finish, inner and outer surfaces 3 4 GTLZ-60-3-ccc-d-0 Fan size (ccc) Version (d) 1 = painted finish, 60 µm 2 = painted finish, 100 µm 3 = wet-painted finish, 250 µm in three layers Motor cover Fläkt Woods Oy FIFLO 4249 GB 02.12 84 GTLZ-77-3-ccc-d-0 Specifications are subject to alteration without notice Fläkt Woods Oy, Kalevantie 39, FI-205 20 Turku, Finland FIFLO 4249A GB 02.12 teleskop reklambyrå 036-30 83 80 t +358-102 230 000 f +358-102 233 475 w www.flaktwoods.com
Similar documents
Gearboxes RS
The helical/worm gearboxes, RA and TA series, made by of an independent single stage helical gearbox FXA fitted to a standard FRS or FTR gearbox, allow greater output torques and higher efficiency ...
More information