PHYSIOMED

Transcription

PHYSIOMED
3
X _-
-d-
О о, ,
[_
Q
О
СЕ
О.
PHYSIOMED
E L E K T R O M E D I Z I N
T E C H N O L O G Y
FOR
T H E R A P Y
-/
T
E
C
H
N
O
L
O
G
Y
T
H
E
R
A
P
Y
EXPERIENCE AND COMPETENCE
With PHYSIOMED products, you are profiting from the fruits of more than
25 years of experience in the development and manufacture of instruments
for physical therapy. We know what we are talking about because we continuously exchange information with users and scientists.
• The start of the company
Physiomed in the old, historical
buildings in Schnaittach
USER F R I E N D L I N E S S AND MAXIMUM SAFETY
We make every effort to maintain our versatile therapy units as user-friendly as
possible - a seemingly simple aspect endowed with far-reaching consequences.
Maximum safety for user and patient is a paramount consideration for us, and
is always the focus of our aspirations.
QUALITY
• The current company area
in Schnaittach-Laipersdorf
Our well-known high quality standard is no matter of chance: "Everything from
one source" is our motto. All steps ranging from ideas through development
and manufacture to the safety check and dispatch of an instrument are taken
care of by PHYSIOMED. Since 1995 our enterprise has been certified as per
ISO 9000, and all our products comply with the Medical Devices Act and feature
the statutory CE0125 mark.
OPTIMAL A F T E R - S A L E S SERVICE AND
RELIABLE PARTNERS
Anyone offering service generally appears on the scene only after the purchase
of an instrument. We endeavour to provide quick and competent assistance
ranging from the initial consultation to the instrument check and repair, if
necessary. Whether on our doorstep, in Russia or in China: you can rely on our
partners and on us.
• The Physiomed III of the year
1975. An instrument for stimu-
lation current with a vacuum
part. With Physiomed you profit
from more than 25 years of
experience in physical therapy.
EXPERT-LINE
••
/
/
tf
*
,£•
"*•
/
-3-
/ 1 MHz 3MHz
IF AMF MT KOTS
/
<y
^
£
л(У
•?"
Q*
•&
$
lONOSON-Expertl
>3>
&
J?
' // / /
(J
-У
'$
&
$
//
/ /t
* / /'
С?*
PHYSIOMED-Expert|
л<ff<f
PHYSIOSON-Expertl
lONOSON-fxpert
HYSIOMED-Fxpert
'HYSIOSON-Expert
'HYSIOVAC-fxpert
BASIC-LINE
PHYSIODYN-DUO
PHYSIODYN-M2
/
IF AMF MT KOTS
/
1MHz 3MHz
PHYSIOMED-22port|
PHYSIOVAC 62]
PHYSIODYN-DUO
PHYSIODYN-M2
PHYSIODYN-V
э
НУ510МЕО-22роИ
-
PHYSIOVAC 62
**,
•
PHYSIOSON-02
HYSIODYN-V
PHYSIOSION-03/ОЗА!
PHYSIOSON-02
PHYSIOSION-03
PHYSIOSON-03A
PHYSIOTHERMI
B
HIVAMAT 200
*with accessory Physiodyn-S
HIVAMAT® 200»
T
E
C
H
N
O
L
O
G
Y
• STIMULATION CURRENT
Medium-frequency currents:
Medium-frequency currents are alternating currents
which are formed by superimposition of a basic
frequency (2-7 kHz) on a modulation frequency
(0-250 Hz). Medium-frequency currents are very
impressive by virtue of their therapeutic efficacy with
minimal skin irritation, pronounced depth effect and
hence good acceptance on the part of the patient.
| IF ::|= Classic interferential current. Interferential
current is generated in the patient's body via 4 electrodes.
| ПНР |= Amplitude-modulated medium-frequency
current. A current pre-modulated in the instrument.
Advantages: application with 2 or 4 electrodes, hence
concurrent treatment of two treatment regions as
well as a more homogenous treatment field.
= Medium-frequency muscle stimulation
= Russian Technique. Very widespread, mediumfrequency current particularly suited to muscle stimulation.
Low-frequency currents:
With the various low-frequency currents (galvanic
current = | G |; diadynamic currents =
ultrastimulation current =
high
| CP |,f LP
voltage = ни |; faradic surge current = Fas I, transcutaneous electric nerve stimulation =|TEHS|; pulsed
galvanisation = IG30
IG50 |; frequency-modulated
current = FM ; stochastic current =|STOCH|; exponential current = | T/R |) the entire spectrum of stimulation current therapy can be covered. As opposed to
medium-frequency currents, certain low-frequency
currents can also be employed for iontophoresis as
well as for paralysis therapy.
Diagnostic currents:
1Я curve for quantitative assessment of neuromuscular
damage. Faradic excitability test and medium-frequency test according to Lange for qualitative rapid
diagnosis of denervation.
"Potpourri"
Automatic succession of a current sequence that
has been exactly set in advance, e.g. 1.[TENS] 2 min.,
2.| flMF |3 min., 3.| DF |2 min.
Two channels:
Two independent channels with provision for setting
individual intensities. For concomitant treatment
of two different sensitive treatment areas using two
different currents:
e.g. channel I -> "real" galvanisation! s~l:
channel II -> I AMF I
ПРЕДСТАВИТЕЛЬСТВО
В СТРАНАХ СНГ
F
O
R
T
H
E
R
A
P
Y
• VACUUM
Vacuum electrodes are the ideal complement for conventional application of stimulation currents via plate
or suction electrodes. Enhanced potential transition
and activation of therapy by means of suctionwaves,
optimal adaptation to body contours, also for manual
suctionwave massage.
Vacustop: Self-closing vacuum electrodes, pump switches off after generation of an adequate vacuum.
• ULTRASOUND
Soundwaves employed in the form of continuous
ultrasound or pulsed ultrasound, which are transmitted to the patient with the transducer (2,5 cm2; 5 cm2)
and absorbed with different intensities in the tissue.
Effect: pain alleviation, trophic enhancement, detoning, mobility enhancement.
Ultrasound Frequencies:
1 MHz for treatment of deep tissue layers such as
bones, joints.
3 MHz for ultrasound treatment of the upper tissue
layers such as for treatment of scars.
• FEATURES
LCD Comfort
Large, clearly structured liquid crystal display (LCD) for
greater transparency and optimised operation.
Indications Index:
Access therapy via an alphabetically sorted list of indications with automatic call of a treatment program.
Individual Program Memories
Individually adjustable and easily accessible program
memories for frequently used treatment programs.
• MICROWAVE
THERAPY
The effect of microwave therapy is based on the
evolution of heat in the deep tissue layers. Due to
their physical properties, microwaves penetrate very
deep into the tissue without warming the upper tissue
layers. The principle effects mediated by microwave
treatment are: enhancement of perfusion, pain
alleviation as well as activation of cell metabolism.
• DEEP OSCILLATION WITH THE HIVAMAT® 200
Deep oscillation treatment for more effective physical
therapy, shorter treatment times and accelerated rehabilitation. An electrostatic field between the therapist's hand and the patient's tissue generates a very
deep-action and sustained resonance oscillation of
the treated tissue sections. Main applications: drainage therapy, sports physiotherapy, respiratory tract
deseases.
'
Переяславская, дЛ4, еф.144
Тел.+факс 007/095/974-14-06
E-mail: Jordagn@Yahoo.com
PHYSIOMED ELEKTROMEDIZIN AG
Hutweide 10
D-91220 Schnaittach/Laipersdorf
Germany
Telefon: (091 26) 2587-0
Telefax: (09126) 2Б 87-25
e-mail: info@physiqmed.de
internet: http://www.physiomed.de
T E C H N O L O G Y
F O R
T H E R A P Y
О
1Л
О
1Л
P H Y S I O S O N - F x p e r f
T H E
E X C L U S I V E
U L T R A S O U N D
T H E R A P Y
PHYSIOMED
E L E K T R O M E D I Z I N
UNIT
Uj
P H Y S I O S O N - F x p e r f - the exclusive
Continuous and pulsed ultrasound
ultrasound therapy unit with 1 and 3 MHz
output.
in one head, indications index and indivi-
Duty cycles:
dual program memory ...
MODE
Pulse
Pause
1/10
1 mS
9mS
LCD Comfort Display for especially good
1/5
2 mS
8mS
JP
?Й
transparency and user-friendly operation.
1/3
3,3 mS
6,6 mS
itifa
2/5
4mS
6 mS
Two frequencies in both transducers: the
2
cont.
TECHNICAL DATA:
Output: max 2,3 W/cm2
Power consumption: 70 W
Graphics
в
^•L
v%
JK^XX/I
- continuous -
Dimensions (W x H x D):
345 x 1 3 3 x 2 6 7 mm
Weight: 3,9 kg
*fa£
1
W///A
2
small (2,5 cm ) as well as the large (5 cm )
transducers operate in the frequencies
Coupling control: optical on unit and ultra-
1 and 3 MHz. The ergonomic high-grade
sound probe, as well as acoustic.
ACCESSORIES (STANDARD):
1 Transducer, optionally
1
1
1
1
steel transducers offer the highest possible
safety for ultrasound output and are also
An extensive Indications Index for acces-
watertight.
sing therapy via an alphabetically sorted
list of indications, with automatic call of a
treatment program featuring a suggested
V/l
Rated voltage: 230 V +/- 10%
Class of protection: 1, type BF
1
5 cm' / 2,5 cm;
Accessory tray
Mains cable
Bottle of ultrasound gel
Operating Manual
Ultrasound therapy booklet
ACCESSORIES (SPECIAL):
additional transducer,
optionally 5 cm2 / 2,5 cm2
dosage.
Trolley Expert
Individual Program Memories: 4 indivi-
OTHER ACCESSORIES:
dually adjustable and easily accessible
see list of accessories
program memories for frequently used
treatment programs.
PHYSIOMED instruments comply with the latest safety standards and the provisions of the
Medical Devices Act. They are
manufactured as per the current standards of quality assurance, have passed a type test
and feature the statutory CE
mark pursuant to Directive
93/42/EEC.
rmaosa, •
„
Can be combined with the stimulation
current unit PHYSIOMED-fxpertfor
simultaneous treatment.
T E C H N O L O G Y
F O R
T H E R A P Y
П РЕДСТАВИТЕЛ ЬСТВО
В СТРАНАХ СНГ
ул.Средняя Переяславская, д.14, оф.144
Тел.+Факс 007/095/974-14-06
E-mail: Jordagn@Yahoo:Com
Therapy unit incl.
• Trolley
• Accessory tray
• Stimulation
currents unit
PHYSIOMED-fxpert
• Vacuum
application unit
PHYSIOVAC-fxpert
PHYSIOMED ELEKTROMEDIZIN AG
Hutweide 10
D-91220 Schnaittach/Laipersdorf
Germany
Telefon: (09126) 2587-0
Telefax: (09126) 2587-25
e-mail: info@physiomed.de
internet: http://www.physiomed.de
03-
615.
s
- 0(3)
T E C H N O L O G Y
F O R
T H E R A P Y
О)
о.
LJ
Ш
J .3 О
о
CO
О
l O N O S O N - f x p e r t
T H E
C O M B I N A T I O N
S T I M U L A T I O N
UNIT
F O R
C U R R E N T
A N D
T W O - C H A N N E L
U L T R A S O U N D
PHYSIOMED
E L E K T R O M E D I Z I N
? 9
lONOSON-Expert - An Imposing Design
Continuous and pulsed ultrasound output.
and LCD Comfort Display for especially
V»
0)
Q.
MEDIUM-FREQUENCY
good transparency and user-friendly
Duty cycles
operation.
MODE
• STIMULATION CURRENT
Pulse
1/10
1 mS
Pause
Q m<;
1/5
2 mS
8 m<:
1/3
3 ,3 mS
X
Separate or simultaneous treatment. An
2/5
4mS
Extensive Indications Index for accessing
cont.
Uj
therapy optionally via a disease, with treat-
AND ULTRASOUND
T Y P E S OF C U R R E N T :
cont
Graphics
jj"
|J_
б к m^
к m<;
yr,i|C
n
ТЙ
^
'^
•ГШ
^
^^*"
-
&7////////////Л
ment proposal for ultrasound, stimulation
Counlina cc introl: r mtiral on unit and
current and simultaneous treatment.
ultrasound probe, as well as acoustic.
Individual Program Memories: easily programmed and called, for frequently used
• STIMULATION CURRENT
standard treatment programs.
Flexibility of treatment by virtue of two
independent channels with provision for
• ULTRASOUND
setting individual intensities. For concomi-
Two frequencies in both transducers: the
tant treatment of two treatment areas of
small (2,5 cm2) as well as the large (5 cm2)
different sensitivity or of two patients with
transducer operate in the frequencies 1
different currents: e g. channel I -> "real"
and 3 MHz. The ergonomic high-grade
galvanic current G, channel II -> AMF.
steel transducers offer the highest possible
safety for ultrasound output and are
Potpourris: Current sequence (e.g.
watertight.
1. TENS = 5 min; 2. AMF = 3 min,
IF Classical interferential current
Basic frequency 2-9,5 kHz
Frequency bands 0-250 Hz arbitrary
Vector function
AMF bipolar interferential current
Basic frequency 2 kHz-9.5 kHz;
Modulation frequency 0-250 Hz;
Frequency bands 0-250 Hz arbitrary;
Two-channel AMF;
MT (Medium-frequency muscle
stimulation)
Basic frequency 2-9,5 kHz; Modulation frequency 0-125 Hz; contraction
1-60 s, pause 1-60 s; Two-channel MT:
alternating/parallel stimulation
KOTS (Russian Technique)
Basic setting: Т = 10 ms, R = 10 ms
Basic frequency 2-9,5 kHz;
Modulation frequency 0-125 Hz;
contraction 1-60 s, pause 1-60 s;
Two-channel KOTS: alternating/parallel stimulation
3. DF = 4 min) according to previously
defined parameters.
E C H N O L O G Y
F O R
T H E R A P Y
ПРЕДСТАВИТЕЛЬСТВО
В СТРАНАХ СНГ
1Я Д
ул.СРТел.+Факс
едн?
' ^
007/095/974-14-06
E-mail: JorJagn&Yahoc.ccm
PHYSIOMED ELEKTROMEDIZIN AG
Hutweide 10
D-91220 Schnaittach/Laipersdorf
Germany
Telefon: (09126) 2587-0
Telefax: (09126) 2587-25
e-mail: info@physiomed.de
internet: http://www.physiomed.de
TECHNICAL DATA:
• Stimulation current
Output max:
75 mA / 500 ohms per channel,
G = 2 5 m A /500 ohms
Power consumption: 75 W
Rated voltage: 230 V +/- 10 %
Class: 1, Type BF
Dimensions: 345 x 133 x 348 mm
Weight: 5,5 kg
• Ultrasound
Output:
max. 2,3 W7cm2at 1 MHz,
max. 1,0 W/cm2 at 3 MHz
ACCESSORIES (STANDARD):
1 Accessory tray
4 Flexo-electrodes 2xEF50,
2xEF10 incl. viscose covers
4 Velcro straps 2x80, 2x125 cm
1 Patient lead
2 Connection leads with PM-Clip,
red and blue
1 PHYSIOPADS adhesive electrodes
8 x 6 cm (pack of 4)
1 PHYSIOPADS adhesive electrodes
6 x 4 cm (pack of 4)
1 Manual release key
1 Transducer, optionally
5 cm 2 /2,5 cm2
1 Bottle of ultrasound gel
1 Operating Manual
1 Mains cable
1 Stimulation current therapy
booklet
1 Ultrasound therapy booklet
ACCESSORIES (SPECIAL):
additional transducer,
optionally 5 cm2 / 2,5 cm2
Trolley Expert
OTHER ACCESSORIES:
see List of Accessories
PHYSIOMED instruments comply
with the latest safety standards
and the provisions of the Medical
Devices Act. They are manufactured as per the current standards
of quality assurance, have passed a
type test and feature the statutory
CE mark pursuant to Directive
93/42.
Geprufte
Qualitatssicherung
MADE
IN G E R M A N Y
Telefon: (09126)2587-0
Telefax: (09126)2587-25
e-mail: info@physiomed.de
internet: http://www.physiomed.de
LOW-FREQUENCY
G "real" Galvanic current and
medium-frequency interrupted direct
current (Iontophoresis)
DF (100 Hz)
MF (50 Hz)
CP(100 Hz/50Hz)
LP(100 H z / 5 0 Hz)
Diadynamic currents optional:
galv. basis 5 %
UR Ultrastimulation current 143 Hz
HV High voltage current 1-200 Hz;
2 Frequency bands; Bursts 1-10 Hz;
TENS 1-200 Hz; 2 Frequency bands;
Bursts 1-10 Hz;
IG30 Pulsed galvanisation 12 Hz
IG50 Pulsed galvanisation 8 Hz
FM Frequency mod. current 7-14 Hz
STOCH Stochastic 10-100 Hz
HVS High-voltage stimulation
1-200 Hz; contraction 1-60 s;
pause 1-60 s; 4 ramps;
Two-channel HVS
FaS Farad, surge current;
contraction 1-60 s; pause 1-60 s;
4 ramps;
T/R Exponential current Т = 0,1 ms1 s; R = 1 ms-7 s; Rectangular, triangular as well as 6 other pulse shapes;
manual triggering
All low frequency current except G,
DF.MF.CP.LP in mono- and biphasic
mode
DIAGNOSIS
Faradic excitability test
Т = 1 ms; R = 20 ms; 48 Hz
Medium-frequency test ace. to Lange
Т = 1 ms; ramp = 20 ms; R = 1-7 s
Accomodation quotient
Rheobase/ Chronaxy
l/T-Diagnostics
Т = 0,1 - 1000 ms; R = 2 s;
triangular/ rectangular pulse
Therapy unit incl.
• Trolley
• Accessory tray
• Vacuum
application unit
PHYSIOVAC-fxpert
/о///)
~*_t_T/
Т Е С Н N О L O G Y
F O R
T H E R A P Y
£
Ul
ll
ь] '."•
3r
о,
crt
>I
a.
P H Y S I O M E D - E x p e r f
T H E
T W O - C H A N N E L
O F
T H E
S T I M U L A T I O N
C U R R E N T
S U P E R L A T I V E
C L A S S
PHYSIOMED
E L E K T R O M E D I Z I N
UNITS
PHYSIOMED-fxperf - an Imposing
Design and LCD Comfort Display for
especially good transparency and userfriendly operation.
Flexibility of treatment by virtue of two
independent channels with provision
Uj
for setting individual intensities. For
concomitant treatment of two treatment
areas of different sensitivity or of two
patients with different currents:
e.g. channel I -> "real" galvanic current G,
channel II -> AMF.
An Extensive Indications Index for
accessing therapy optionally via a disease,
TYPES OF
CURRENT:
MEDIUM-FREQUENCY
with treatment proposal. /\
IF Classical interferential current
Individual program memories, easily
programmed and called, for frequently
used standard treatment programs.
Basic frequency 2-9,5 kHz;
Modulation frequency 0-250 Hz;
Frequency bands 0-250 Hz arbitrary;
Vector function
AMF bipolar interferential current
Potpourris: Current sequence
(e.g. 1. TENS = 5 min; 2. AMF = 3 min,
3. DF = 4min) according to previously
defined parameters.
Basic frequency 2-9,5 kHz;
Modulation frequency 0-250 Hz;
Frequency bands 0-250 Hz arbitrary;
Two-channel AMF
MT (Medium-frequency muscle
stimulation)
Basic frequency 2-9,5 kHz; Modula-
tion frequency 0-125 Hz; contraction
1-60 s, pause 1-60 s; Two-channe MT:
alternating/parallel stimulation
KOTS (Russian Technique)
Basic setting: Т = 10 ms, R = 10 ms
Basic frequency 2-9,5 kHz;
Modulation frequency 0-125 Hz;
contraction 1-60 s, pause 1-60 s;
Two-channel KOTS: alternating/parallel stimulation
Can be combined with the ultrasound therapy unit PHYSIOSONExpert for simultaneous therapy.
T E C H N O L O G Y
F O R
T H E R A P Y
ПРЕДСТАВИТЕЛЬСТВО
В СТРАНАХ СНГ
уд.Средняя Переяславская, д. 14, оф.144
Тел.+Факс 007/095/974-14-06
E-mail: Jordagn@Yahoo.com
PHYSIOMED ELEKTROMEDIZIN AG
Hutweide 10
D-91220 Schnaittach/Laipersdorf
Germany
Telefon: (09126) 2587-0
Telefax: (09126) 2587-25
e-mail: info@physiomed.de
internet: http://www.physiomed.de
.TECHNICAL DATA:
Output max:
75 m A / 500 ohms per channel,
tjx= 2 5 m A / 500 ohms
Power consumption: 50 W
Rated Voltage: 230 V +/- 10 %
x Class: 1, Type BF
dimensions (W x H x D):
345 x 1 3 3 x 3 4 8 mm
Weight: 5,1 kg
ACCESSORIES (STANDARD):
1 Accessory tray
4 Flexo-electrodes 2xEF50, 2xEF10
incl. viscose covers
4 Velcro straps 2x80, 2x125 cm
1 Patient lead
2 Connection leads with PM-Clip,
red and blue
1 PHY5IOPADS adhesive electrodes
8x6 cm (pack of 4)
1 PHYSIOPADS adhesive electrodes
6x4 cm (pack of 4)
1 Manual release key
1 Mains cable
1 Operating Manual
1 Stimulation current therapy
booklet
ACCESSORIES (SPECIAL):
Trolley Expert
OTHER ACCESSORIES:
see List of Accessories
PHYSIOMED instruments comply
with the latest safety standards
and the provisions of the Medical
Devices Act. They are manufactured as per the current standards
of quality assurance, have passed a
type test and feature the statutory
CE mark pursuant to Directive
93/42.
Q-
Geprufte
Quaiitatssicherung
MADE
IN
GERMANY
Telefon: (09126) 2587-0
Telefax: (09126) 2587-25
e-mail: info@physiomed.de
internet: http://www.physiomed.de
LOW-FREQUENCY
G "real" Galvanic current and
medium-frequency interrupted direct
current (Iontophoresis)
DF(100 Hz)
MF (50 Hz)
CP(100 Hz/50Hz)
LP(100 H z / 5 0 Hz)
Diadynamic currents optional:
galv. basis 5 %
UR Ultrastimulation current 143 Hz
HV High voltage current 1-200 Hz;
2 Frequency bands; Bursts 1-10 Hz;
TENS 1-200 Hz; 2 Frequency bands;
Bursts 1-10 Hz;
IG30 Pulsed galvanisation 12 Hz
IG50 Pulsed galvanisation 8 Hz
FM Frequency mod. current 7-14 Hz
STOCH Stochastic 10-100 Hz
HVS High-voltage stimulation
1-200 Hz; contraction 1-60 s;
pause 1-60 s; 4 ramps;
Two-channel HVS
FaS Farad, surge current;
contraction 1-60 s; pause 1-60 s;
4 ramps;
T/R Exponential current Т = 0,1 ms1 s; R = 1 ms-7 s; Rectangular, triangular as well as 6 other pulse shapes;
manual triggering
All low frequency current except G,
DF,MF,CP,LP in mono- and biphasic
mode
DIAGNOSIS
Faradic excitability test
Т = 1 ms; R = 20 ms; 48 Hz
Medium-frequency test ace. to Lange
Т = 1 ms; ramp = 20 ms; R = 1-7 s
Accomodation quotient
Rheobase/ Chronaxy
l/T-Diagnostics
Т = 0,1 - 1000ms; R = 2 s;
triangular/ rectangular pulse
Therapy unit incl.
• Trolley
• Accessory tray
• Ultrasound therapy
unit PHYSIOSON-fxpert
• Vacuum application
unit PHYSIOVAC-fxpert
01
T E C H N O L O G Y
F O R
T H E R A P Y
QJ
Q.
A
•-^ i—
>
о
1Л
Q.
P H Y S I O V A C - f x p e r t
T H E
M I C R O P R O C E S S O R - C O N T R O L L E D
V A C U U M
A P P L I C A T I O N
UNIT
PHYSIOMED
E L E K T R O M E D I Z I N
V.
OJ
Uj
и
PHYSIOVAC-Experf - The microprocessorcontrolled vacuum application unit for
combination with EXPERT-LINE stimulation
current units...
The vacuum application unit PHYSIOVAC-fxpert is the ideal complement to
the stimulation current unit PHYSIOMEDExpert and the combination unit IONOSON-fxpert. By virtue of its ergonomic
design, the PHYSIOVAC-Expert upgrades
your combination of units to an impressive
therapy station.
The unit is also very well suited for
vacuotherapy.
Vacustop suction electrodes (self-closing).
TECHNICAL DATA:
Self-adjusting vacuum circuit with automatic pump switch-off. Constantly controlled
vacuum.
Low-noise, quiet method of operation.
Vacuum: 0 - -0,6 bar
Pulsation: 10-60 pulsations/min,
infinitely variable
Power consumption: 23 W
Rated voltage 230 V +/-10 %
Class: 1, type BF
Dimensions (W x H x D):
3 4 5 x 1 2 9 x 4 1 6 mm
Weight: 4,5 kg
Infinitely variable pulsation for activation
of therapy and suction-wave massage.
Water trap with level indicator and automatic unit switch-off.
ACCESSORIES (STANDARD):
4 Vacustop suction cups
diameter 60 mm
8 sponges for suction cups
diameter 60 mm
4 Vacuum hoses
1 Connection lead to
stimulation current unit
1 Mains connection cable
1 Mains cable
1 Operating Manual
Clearly arranged manual control elements
for easy operation. LED indicator for the
vacuum.
ACCESSORIES (SPECIAL):
Vacustop suction cups
diameter 90 mm
Sponges for Vacustop suction
cups diameter 90 mm
Suctionwave cups made from
Luran
X
OTHER ACCESSORIES:
see List of Accessories
а.
PHYSIOMED instruments comply
with the latest safety standards
and the provisions of the Medical Devices Act. They are manufactured as per the current standards of quality assurance, have
passed a type test and feature
the statutory CE mark pursuant
to Directive 93/42.
Can be combined with the
stimulation current unit
PHYSIOMED-Expert
and IONOSON-£xpert.
T E C H N O L O G Y
F O R
T H E R A P Y
Therapy unit incl.
• Trolley
• Accessory tray
• Ultrasound
therapy unit
PHYSIOSON-fxpert
• Stimulation
currents unit
PHYSIOMED-fxpert
PHYSIOMED ELEKTROMEDIZIN AG
Hutweide 10
D-91220 Schnaittach/Laipersdorf
Germany
Telefon: (09126)2587-0
Telefax: л- '1: 2БЕ7-2:
e-mail: info@physiomed.de
internet: http://www.physiomed.de