2011 Canvys Healthcare Catalog
Transcription
2011 Canvys Healthcare Catalog
Table of Contents Canvys Display Solutions: Healthcare Products and Services ................................................................. 3 Image Systems High Bright Color Displays – 2MP / 3MP ....................................................................... 7 Image Systems Grayscale Displays – 2MP / 3MP ................................................................................. 9 Image Systems MX5MP Grayscale Display ......................................................................................... 11 WIDE MW10MP Grayscale Display .................................................................................................... 13 Image Systems CL2000 2MP Color Clinical Review Display .................................................................. 15 Image Systems FP1800MBNC ......................................................................................................... 17 Image Systems FP4201-MED .......................................................................................................... 19 Medical Modality LCDs - Patient Monitoring Series .............................................................................. 21 DOME Grayscale LCD ..................................................................................................................... 23 DOME Color LCD ........................................................................................................................... 25 EIZO RadiForce® .......................................................................................................................... 27 Canvys Medical Imaging Displays: NEC MultiSync® MD304MC .............................................................. 29 Canvys Medical Imaging Displays: NEC MultiSync® MD Series .............................................................. 31 Canvys DICOM® Calibrated Mobile Workstation Solution for Healthcare ................................................. 33 CFS™ WebSuite ............................................................................................................................ 35 Image Systems Medical Display Bundles ........................................................................................... 37 Canvys Quality Control & Quality Assurance Services ......................................................................... 39 Canvys Hot Swap - Extended Warranty & Advance Replacement Program .............................................. 41 Healthcare A Division of Richardson Electronics Canvys Display Solutions: Healthcare Products and Services Because it has to be right As a longtime provider of display solutions for the healthcare market, Canvys has the expertise to deliver medical imaging and advanced display systems your staff needs. We specialize in creating comprehensive solutions for diagnostic and clinical review, 3-D and post processing, surgical suites and modality-specific applications. Plus, all of our solutions meet the most critical agency certifications and calibration standards for patient monitoring, bio-medical displays, ultrasound, cardiac imaging and PACS. Our healthcare services include: • On-site facility audits to determine your unique needs • Custom engineering and system integration • Hardware installation • Management and maintenance of your system throughout its lifecycle • Component hot-swapping • On-site user training and calibration Canvys also understands that the health of your patients depends on flawlessly performing systems. That’s why we offer you expert support through TekLink®, our professional services group. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 3 Healthcare A Division of Richardson Electronics Products Image Systems At the core of Canvys’ Healthcare Display Solutions is our private label brand of Image Systems diagnostic and clinical imaging LCDs. Supported out of our Plymouth MN location, Image Systems has been recognized as an industry- leading display brand for the last 20 years by consistently providing the highest quality diagnostic and clinical display solutions to the healthcare industry. A critical component of every Image Systems display bundle is our proprietary Calibration Feedback Software (CFS™). The Image Systems engineering team recognizes that it is critical for radiology displays to present accurate and consistent images over time. Our Image Systems CFS™ calibration software is specifically designed to simplify the conformance and calibration of all Image Systems diagnostic and clinical use displays ensuring they maintain DICOM ® compliance and are properly calibrated throughout their life-cycle. Display and Accessories Partners Canvys is committed to understanding your visual technology needs and delivering a healthcare display solution that exceeds your expectations. In order to deliver the right solution, Canvys offers other best in class brands such as NDS/Dome, NEC, Eizo, Hewlett Packard, Mediamounts and NVIDIA. In addition, our technical services teams are imaging experts allowing us to trouble shoot, offer advance replacement and support any brand of display solution that you purchase from Canvys. This customer-focused approach is just one of the many reasons companies choose to work with us. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 4 Healthcare A Division of Richardson Electronics Accessories Mounting Solutions Canvys delivers the highest quality imaging display solutions designed specifically for use in healthcare applications. Our innovative mobile and fixed display mounting solutions improve digital display performance wherever you need them. Improve access, efficiency and accuracy in the OR, ICU, radiology and lab by professionally integrating your LCD monitor, keyboard and CPU at the point of care. • Floor Mounts • Mobile Workstations • Large Screen Mounts Workstations Our expert team draws on their extensive design, service and support experience to develop platform solutions that address your needs. We consider: Software Requirements – including the baseline processing and memory requirements of your imaging software and operating system, as well as other software you anticipate adding Environment – including any physical restrictions that may impact processing power and functionality, such as space limitations and ambient temperature and environment hazards Expandability – we help you determine the importance of easy upgrades to your institution by designing solutions that can meet today’s and tomorrow’s standards Additional Peripherals – including everything from additional keyboards and battery backups to surge protectors, printers, and scanners A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 5 Healthcare A Division of Richardson Electronics Services We understand that visual technology poses challenges that go beyond acquiring the right solution. That’s why we offer comprehensive services to ensure your system is installed properly and consistently delivers the superior performance you expect. In addition to 24/7 online and phone support, we have visual technology experts who can provide an array of on-site services. QC/QA Canvys offers Quality Control and Quality Assurance services for your entire fleet of medical imaging monitors. The QC/QA on-site service program is ideal for facilities without the expertise or resources to maintain the confor mance and calibration of multiple medical displays. TekLink ® TekLink ® provides superior technical support via 24/7 online and phone support and access to our visual technology experts. We understand that visual technology poses challenges that go beyond acquiring the right solution. TekLink ® is a web-based support system that allows you to request support, return authorizations, and many other features. Extended Warranty Program - Hot Swap At Canvys, our superb product quality reflects our commitment to excellence. We realize that occasionally hardware components can fail. We understand not all businesses are alike and in many instances, daily display solution performance is critical to the success of the company. The Canvys Hot Swap Advance Replacement Program was designed as a coverage plan for our customers to manage through these rare occasions. Standard in-warranty repair claims could take weeks for a replacement and sometimes longer. With the Canvys Hot Swap premium warranty service, customers can rest assured that the defective parts or products will be replaced within 24 hours*. Hot Swap Optional Extended Warranty & Advance Replacement Program * For problems diagnosed prior to 4P.M. CST, advance replacements will ship the same day. Replacements for problems diagnosed after 4P.M. CST will ship the next business day. Specifications subject to change without notice. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 6 Healthcare Diagnostic & Clinical Review Color LCD A Division of Richardson Electronics 2 MP Image Systems High Bright Color Displays 3 MP Because it has to be right • High brightness and contrast • Medical grade • Backlight stabilization circuitry • Retractable self-calibrating front sensor • Ambient light sensor Canvys’ Image Systems brand of medical grade imaging displays again sets the standard for quality, flexibility, and accuracy in diagnostic LCDs. Exceptionally high brightness, high contrast ratios and calibration capabilities present consistent diagnostic quality images that enhance workflow for applications requiring a fusion of color and grayscale including PET, 3D, Cardiology and Nuclear Medicine. The retractable front sensors, coupled with Image These high performance diagnostic displays are Systems’ Calibration Feedback System (CFS), designed to utilize commercial off-the-shelf (COTS) allow users to easily perform color point calibration, graphics cards to make them more flexible and color matching and DICOM ® part 14 calibrations. affordable for end-users. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 7 Healthcare Diagnostic & Clinical Review Color LCD A Division of Richardson Electronics 2 MP Specifications & Features 2MP COLOR HB (X-Series) CX2MP Series Model / Type 3MP COLOR HB (X-Series) CX3MP LCD panel 21.3”/ 540 mm Resolution 2MP (1200 × 1600) Pixel pitch (H × V) 0.270 × 0.270 mm 0.21075 × 0.21075 mm Brightness (max.) 860 cd/m² 900 cd/m² 21.2” / 539.5 mm 20.8” / 528 mm 3MP (1536 × 2048) 0.207 × 0.207 mm 600 cd/m² 450 cd/m² (typ.) 400 cd/m² (typ.) Contrast ratio (typ.) 1050:1 1000:1 600:1 w/o LUC 500:1 w/ LUC Viewing angle (H×V) 176° / 176° 176° / 176° 170° / 170° Input signal DVI-D, DisplayPort H-sync: 75 - 78 kHz V-sync: 60 - 62 Hz Dot CLK: 162 - 170 MHz (single) Sync type SPECS & FEATURES 3MP COLOR HB (P-Series) FPP2080C TFT AMLCD IPS Color Screen size Brightness calibrated Calibration Feedback System - CFS™ 3 MP Bit depth DVI-D H-sync: 92 - 98 kHz V-sync: 58 - 62 Hz Dot CLK: 120 - 132 MHz (dual) 14 bit 12 bit Rotating retractable front sensor with CFS s/w enables color point and DICOM® 3.14 calibration Retractable front sensor with CFS - enables color point and DICOM® 3.14 calibration Accurate and consistent presentation of images is a critical requirement for Calibration radiology displays. Image Systems’ Calibration Feedback System (CFS™) ensures your display is calibrated properly tomeet TG18 and Admin software Local: CFS | Enterprise: CFS WebSuite Sensors front, rear, ambient, temp. DICOM ® 3.14 standards. Power supply Self-Calibration Front Sensor Assures life-time DICOM ® 3.14 compliance. Power consumption Stable Brightness Control Power save mode Automatically with rear backlight sensor. Operating 100 W max 105 W max 110 W DVI DMPM - less than 1 W DVI DMPM 0° to 40 °C 0° to 35 °C Storage Calibration Precision AC Input: AC100-240 V ±10%, 60 Hz / 50 Hz ± 3Hz DC output:+12 V, 6.67 A (internal) AC Input: AC100-240 V ±10%, 60 Hz / 50 Hz ± 3Hz -20° to 60 °C; 4° to 140° F VESA mounting 100 × 100 mm Look-up Tables up to 14 bits. Digital Ambient Light Sensor Warns on significant room lighting changes. Weight with stand without stand Luminance Uniformity Control Optimizes uniformity across screen. Certifications 11.0 kg (24.25 lbs) 7.5 kg (16.53 lbs) UL60601-1, CSA std., C22.2 No. 601.1, IEC/EN60601-1, CE, FCC Class B, ICES-003-B, VCCIB , CCC, KCC, C-Tick Warranty About Image Systems For the last 20 years, Image Systems has Other 11.5 kg (25.35 lbs) 8.0 kg (17.64 lbs) 9.2 kg (16.3 lbs) 6.4 kg (10.1 lbs) UL60601-1, CE, CCC, IEC/EN6060-1, FCC Class B, VCCI, CE, MIC, CCC 60 months Luminance Uniformity Control (LUC), USB, LED PrivateLight, self diagnostic tool LUC, USB been recognized as an industry-leading display brand by consistently providing the highest quality diagnostic and clinical Comprehensive Technical Support display solutions to the healthcare industry. Learn more at teklink.canvys.com Hot Swap Extended Warranty & Advance Replacement Program A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 8 Healthcare Diagnostic & Clinical Review Grayscale LCD A Division of Richardson Electronics 2 MP Image Systems Grayscale Displays 3 MP Because it has to be right • Precise gray-shades • Medical grade • Luminance Uniformity Control • Digital ambient light sensor • Retractable self-calibrating front sensor Radiologists have come to expect highly accurate and calibrated displays from Image Systems enabling them to promote positive patient outcomes. We continue to meet these expectations with the Image Systems Professional Series 2 and 3Mega-Pixel LCDs. These displays offer functionality that is tied to our proprietary Calibration Feedback System™ (CFS) software assuring users of consistent DICOM ® compliant images throughout the life of their LCD. These high performance diagnostic displays are designed to utilize commercial off-the-shelf (COTS) graphics cards to make them more flexible and affordable for end-users. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 9 Healthcare Diagnostic & Clinical Review Grayscale LCD A Division of Richardson Electronics 2 MP Specifications & Features Series Model / Type 2MP Mono HB (X-Series) MX2MP 3MP Mono HB (X-Series) MX3MP LCD panel Screen size TFT AMLCD IPS Grayscale 21.3” / 541.4 mm 20.8” / 528 mm Viewable image size 432.0 × 324.0 mm 433.1 × 324.8 mm 423.9 × 318.0 mm Resolution 2MP (1200 × 1600) Pixel pitch 0.270 × 0.270 mm 0.2115 × 0.2115 mm 0.207 × 0.207 mm 1650 cd/m² 1450 cd/m² 1000 cd/m² 3MP (1536 × 2048) Brightness calibrated Contrast ratio (typ.) 500 cd/m² (typ.) 850:1 SPECS & FEATURES Input signal Accurate and consistent presentation of images is a critical requirement for Sync type Image Systems’ Calibration Feedback System (CFS™) comes standard with Bit depth every Image Systems display and ensures Calibration your LCD is calibrated properly for DICOM ® Admin software 3.14 compliance. Sensors 176° / 176° 170° / 170° DVI-D, DisplayPort DVI-D H-sync: 75 - 78 kHz V-sync: 60 - 62 Hz Dot CLK: 160 - 170 MHz (single) H-sync: 92 - 98 kHz V-sync: 58 - 62 Hz Dot CLK: 120 - 132 MHz (dual) 14 bit Assures life-time DICOM ® 3.14 compliance. Local: CFS™, Enterprise: CFS™ WebSuite front, rear, ambient, temp. Tilt / swivel / height adjustment 100 × 100 mm -3°, +15° / ±20° / 110 mm Operating Stable Brightness Control 12 bit Built in sensor with Calibration Feedback System (CFS™) enables self-calibration VESA mounting Self-Calibration Front Sensor 900:1 w/o LUC 750:1 w/ LUC 900:1 Viewing angle (H × V) radiology displays. 3MP Mono HB (P-Series) FPP20HXP 21.3” / 540 mm Brightness (max. typ.) Calibration Feedback System - CFS™ 3 MP 3°, ±30° / ±30° / 108 mm 0 to 40 °C Storage -20° to 60 °C; 4° to 140° F Automatically with rear backlight sensor. (internal) AC Input: AC100-240 V ±10%, 60 Hz / 50 Hz ± 3Hz AC 100 - 240 V ±10%, 60/50 Hz ±3 Hz DC 12 V, 6.67 A 85 W 75 W Power saving DVI DMPM - less than 1 W DVI DMPM Certifications UL60601-1, CSA std., C22.2 No. 601.1, IEC/EN60601-1, CE, FCC Class B, ICES-003-B, VCCI-B, CCC, KCC, C-Tick UL60601-1, CE, CCC, IEC/EN6060-1, FCC Class B, VCCI, CE, MIC, CCC Power supply Calibration Precision Look-up Tables up to 14 bits. Power consumption Digital Ambient Light Sensor Warns on significant room lighting changes. Luminance Uniformity Control Optimizes uniformity across screen. Warranty display About Image Systems Other For the last 20 years, Image Systems has 60 months Luminance Uniformity Control (LUC), USB, LED PrivateLight, self diagnostic tool LUC, USB been recognized as an industry-leading display brand by consistently providing the highest quality diagnostic and clinical display solutions to the healthcare industry. Hot Swap Comprehensive Technical Support Learn more at teklink.canvys.com Extended Warranty & Advance Replacement Program A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 10 Healthcare Diagnostic & Clinical Review Grayscale LCD A Division of Richardson Electronics Image Systems MX5MP Grayscale Display 5 MP Because it has to be right • Superior luminance performance • 14-bits grayscales for precise expression • Built-in front sensor for DICOM® calibration • Luminance Uniformity Control (LUC) • Digital Ambient Control (DAC) The Image Systems MX5MP 5 Mega Pixel (2048 × 2560), 14 bit grayscale LCD continues to set the standard for Diagnostic Review of Mammography and plain film studies. Delivering superb image quality, maximum brightness of 1100 cd/m² and unsurpassed consistency over the life of the LCD glass, the MX5MP, along with CFS™ Calibration Software, will provide years of accurate, precise images for discerning radiology departments. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 11 Healthcare Diagnostic & Clinical Review Grayscale LCD A Division of Richardson Electronics 5 MP SPECS & FEATURES Specifications & Features Series Model / Type Image Systems MX5MP LCD panel TFT AMLCD IPS Grayscale Screen size 21.3” / 540.9 mm Viewable image size 422.4 × 377.9 mm (16.6” × 13.3”) Resolution 5MP (2048 × 2560) Pixel pitch 0.165 × 0.165 mm Brightness (max. / typ.) 1100 cd/m² Brightness calibrated (typ.) 500 cd/m² Contrast ratio (typ.) 850:1 Viewing angle (H × V) 170° / 170° Input signal DVI-D, Display Port Sync type H-sync: 99 - 107 kHz | V-sync: 47 - 53 Hz Dot CLK: 142 - 152 MHz (dual) Bit depth 14 bit (4096 gradation) Signal cable DVI to DVI Calibration Built in sensor with Calibration Feedback System (CFS™) enables self-calibration radiology displays. Admin software Local: CFS™, Enterprise: CFS™ WebSuite Image Systems’ Calibration Feedback Sensors Front, rear, ambient, temperatue System (CFS™) comes standard with VESA mounting interface 100 × 100 mm every Image Systems display and ensures Weight 12.0 kg (26.45 lb) with stand your LCD is calibrated properly for DICOM ® Tilt / swivel / height adjustment -3°, ±15° / ±20° / 110 mm 3.14 compliance. Operating 0 to 40 °C (32 to 104 °F) Storage -20 to 60 °C (-4 to 140 °F) Power supply (internal) AC 100-240 V ±10%, 60/50 Hz ±3 Hz DC 12 V, 6.67 A Power consumption 85 W max. Power saving DVI DMPM - less than 1 W Certifications UL60601-1, CSA Std. C22.2 NO.601.1, IEC/EN60601-1, FCC Class B, VCCI Class B, KCC, CCC, C-Tick, CE, FDA 510K* Warranty display 60 months - electrical 60 months - backlight to half-life Other Luminance Uniformity Control (LUC), USB, LED PrivateLight, self diagnostic tool Calibration Feedback System - CFS™ Accurate and consistent presentation of images is a critical requirement for Self-Calibration Front Sensor Assures life-time DICOM ® 3.14 compliance Stable Brightness Control Automatically with rear backlight sensor Calibration Precision Look-up Tables up to 14 bits Digital Ambient Light Sensor Warns on significant room lighting changes Luminance Uniformity Control Optimizes uniformity across screen * Please contact your Canvys sales team for details including MQSA documentation. About Image Systems For the last 20 years, Image Systems has been recognized as an industry-leading display brand by consistently providing the Comprehensive Technical Support Learn more at teklink.canvys.com Hot Swap Extended Warranty & Advance Replacement Program highest quality diagnostic and clinical display solutions to the healthcare industry. Detailed technical specifications available upon request. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 12 Healthcare Diagnostic & Clinical Review Grayscale LCD A Division of Richardson Electronics 10 MP WIDE MW10MP Grayscale Display Because it has to be right • Seamless 30” Desktop • Run as 1× 10MP or 2 × 5MP • 14-bits Grayscales for Precise Expression • Built-in Front Sensor for DICOM® Calibration • Luminance Uniformity Control (LUC) • Digital Ambient Control (DAC) The WIDE MW10MP 10 Mega Pixel (4096 × 2560), 14 bit grayscale LCD continues to set the standard for Diagnostic Review of Mammography and plain film studies. Delivering superb image quality, maximum brightness of 1250 cd/m² and unsurpassed consistency over the life of the LCD glass, the MW10MP is the right choice for discerning radiology departments. The ultimate combination in imaging performance: • WIDE MW10MP 10 Megapixel Display • CFS™ WebSuite Calibration Software A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 13 Healthcare Diagnostic & Clinical Review Greyscale LCD A Division of Richardson Electronics 10 MP SPECS & FEATURES Specifications & Features Series Model / Type WIDE MW10MP LCD panel TFT AMLCD IPS Grayscale, true 10 bit panel Screen size 30.0” / 760.75 mm Viewable image size 645.12 × 403.2 mm (25.4” × 15.9”) Resolution 10MP (4096 × 2560) Pixel pitch 0.158 × 0.158 mm Brightness (max. / typ.) 1250 cd/m² Brightness calibrated (typ.) 500 cd/m² Contrast ratio (typ.) 850:1 Viewing angle (H × V) 170° / 170° Input signal DVI-D (2×), Display Port (2×) Sync type H-sync: 99 - 107 kHz | V-sync: 47 - 53 Hz Dot CLK: 142 - 152 MHz (dual) Bit depth 14 bit Calibration Built in sensor with Calibration Feedback System (CFS™) enables self-calibration images is a critical requirement for Admin software Local: CFS™, Enterprise: CFS™ WebSuite radiology displays. Sensors Front, rear, ambient, temperatue Image Systems’ Calibration Feedback VESA mounting interface 100 × 100 mm Weight with stand: without stand: your LCD is calibrated properly for DICOM ® Tilt / swivel / height adjustment -3°, ±15 / ±90° / 110 mm 3.14 compliance. Operating 0 to 40 °C (32 to 104 °F) Storage -20 to 60 °C (-4 to 140 °F) Power supply (internal) AC 100-240 V ±10%, 60/50 Hz ±3 Hz DC 12 V, 6.67 A Power consumption 150 W max. Power saving DVI DMPM - less than 2 W Certifications UL60601-1, CSA Std. C22.2 NO.601.1, IEC/EN60601-1, FCC Class B, VCCI Class B, KCC, CCC, C-Tick, CE, FDA 510K* Warranty display 60 months - electrical 60 months - backlight to half-life Other Luminance Uniformity Control (LUC), USB, LED PrivateLight, self diagnostic tool Calibration Feedback System - CFS™ Accurate and consistent presentation of System (CFS™) comes standard with every Image Systems display and ensures Self-Calibration Front Sensor Assures life-time DICOM ® 3.14 compliance Stable Brightness Control Automatically with rear backlight sensor Calibration Precision Look-up Tables up to 14 bits Digital Ambient Light Sensor 22.0 kg (48.5 lb) 16.0 kg (35.3 lb) Warns on significant room lighting changes Luminance Uniformity Control Optimizes uniformity across screen * Please contact your Canvys sales team for details including MQSA documentation. Comprehensive Technical Support Learn more at teklink.canvys.com Hot Swap Extended Warranty & Advance Replacement Program Detailed technical specifications available upon request. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 14 Healthcare Diagnostic & Clinical Review Color LCD A Division of Richardson Electronics Image Systems CL2000 2MP Color Clinical Review Display 2 MP Because it has to be right • 10-bit color depth • DICOM® calibratable • Wide viewing angle • Backlight stabilization circuitry • Multiple DICOM® modes Canvys’ Image Systems brand CL2000 is a versatile The CL2000 can be calibrated to the DICOM ® and cost effective medical LCD for the clinical review standard utilizing Image Systems CFS software and referral environment. and the display employs multiple DICOM ® modes This UL60601-1 certified display can be used for (clear base, blue base, sRGB, and text) enabling physician review of images with patients as well multi tasking in radiology applications. as complement diagnostic displays in a radiology This feature rich display coupled with Image PACS workstation. Systems service and support offers the lowest cost of ownership in the healthcare industry. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 15 Healthcare Diagnostic & Clinical Review Color LCD A Division of Richardson Electronics 2 MP SPECS & FEATURES Specifications & Features Calibration Feedback System - CFS™ Accurate and consistent presentation of images is a critical requirement for radiology displays. Image Systems’ Calibration Feedback System (CFS™) ensures your display is calibrated properly tomeet TG18 and DICOM standards. Model / Type CL2000 LCD Panel TFT AMLCD IPS Color Active Display Size 408.0 mm × 306.0 mm (16.1” × 12.0”) Display Diagonal 51.054 cm (20.1”) Pixel Pitch 0.255 × 0.255 mm Native Resolution 1600 × 1200 Viewing Angle 178° (hor, ver) at 10:1 contrast Brightness (Typical) 300 cd/m² Contrast (Typical) 800:1 Swivel (L,R) 30°, 30° Tilt (D,U) 3°, 30° Elevation (H) 108 mm Pivot CCW 90° Gradation Display 10-bit gradation (8-bit in/10-bit out) DICOM Mode Clear-base, Blue-base, Text View, sRGB, User Image Stabilization SBC (Stable Brightness Control) Language English, Dutch, French, Spanish, Italian, Japan. Function Control Type Tact Function Video Input D-SUB ×1, DVI ×1 Input Format D-SUB DVI 0.714 Vp-p at 75 Ω Digtial 8-bit (VESA Standard) USBs USB 2.0, up stream (1), down stream (2) Approval EMC Safety FCC Class B, CE, VCCI Class B, MIC, CCC. UL60601-1,CE,CSA Std. C22.2 NO. 601.1 IEC/EN60601-1,CCC Demension (W × H × D) Landscape Portrait 450 × 449 × 225 mm (17.7 × 17.7 × 8.9”) 350 × 500 × 255 mm (13.8 × 19.7 × 8.9”) Weight Unpacked Packed 8.5 kg 10.0 kg About Image Systems For the last 20 years, Image Systems has been recognized as an industry-leading display brand by consistently providing the highest quality diagnostic and clinical display solutions to the healthcare industry. max. 65 W; DPMS Mode ≤ 2 W; Soft Power Off Mode ≤ 1 W Power Consumption Comprehensive Technical Support Learn more at teklink.canvys.com Hot Swap Extended Warranty & Advance Replacement Program Detailed technical specifications available upon request. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 16 Healthcare Modality Grayscale LCD A Division of Richardson Electronics 18.1” Image Systems FP1800MBNC Because it has to be right • Multi-resolution (up to 1280 × 1024) LCD with analog video inputs • New digital video timings over a BNC connector • In Plane Switching (IPS) technology provides excellent viewing angles • Replaces OEM modality displays • Multifunctional inputs Multiple Timings, One Display Upgrade or Replace The Image Systems FP1800MBNC multi-resolution This multi-modality LCD bridges the gap between (up to 1280 × 1024) LCD with analog video inputs original CRT monitors and current digital LCD offers our customers the ultimate solution in technology. Now you can upgrade your monitors flexibility and options. Unlike most digital flat panel without replacing your entire analog system. These displays, the FP1800MBNC will work effectively versatile flat panel displays can interface with the with most current and legacy modality systems. It is video signals of most current and legacy modality pre-programmed with more than 150 standard systems, making the FP1800MBNC the perfect analog video timings for medical applications. And upgrade to keep your analog video system up and more are being added all the time*. running.There’s no need to change video cards, cameras or other external hardware. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 17 Healthcare Modality Grayscale LCD A Division of Richardson Electronics 18.1” Specifications & Features Series Model / Type FP1800MBNC (white bezel) FP1800MBNC-BK (black bezel) Panel size/type 18.1” TFT active matrix LCD, anti-glare and hard coated Pixel dimension 0.2805 × 0.2805 mm Maximum / Native / Optimum resolution 1280 × 1024 Contrast ratio 550:1 typ. Brightness 700 cd/m² typ. Viewing angle Hor: 85° to 85° / Ver: 85° to 85° Display color 16.7M (8 bits) Active display area 359 × 287 mm Analog input Video: 0.7Vpp/75 ohm, Sync: Separate TTL level, composite sync or sync on green, Hor: 30~92 kHz, Ver: 50~85 Hz (60~120 Hz Interlaced) PC Compatible Up to VESA 1280 × 1024 @ 75/60 Hz, VESA 1024 × 768 @ 85/75/70/60 Hz, Analog VESA 800 × 600 @ 85/75/72/60/56 Hz, VESA 640 × 480 @ 85/75/72/60 Hz, Super VGA, VGA, Mac 832 × 624 @75 Hz, Power Mac and more. Video NTSC / PAL B External connector analog input : 15-D sub ×1, BNC ×3 (Video, H-Sync, V-Sync) S Video ×1, Composite or Y CbCr ×1, serial port ×1, Power: AC in Cables 15 pin D-sub cable ×1, AV signal cable Plug & play VESA DDC2B User control and indicator Dial control ×1 for Power and OSD, Power indicator ×1 Pre-Vu OSD, FOR PC: contrast, brightness, auto adjust, clock, phase, hor position, ver position, input select, OSD, Power saving, PIP. FOR VIDEO: contrast, brightness, sharpness, recall, video select. Base stand Tilt, swivel, height and pivot four ways adjustable Replace OEM Modality Displays SPECS & FEATURES • Fluoroscopy • CT • MRI Multifunctional Inputs • Separate TTL level • Composite sync • Sync on green • Termination switch for loop-thru configurations Hot Swap Extended Warranty & Advance Replacement Program With the Canvys Hot Swap premium warranty service, customers can rest assured that the defective parts or products will be replaced within 24 hours** Dimension 432 × 467 × 251 mm • Minimize down time - Maximize productivity Weight Net: 10.9 kg • Direct access to expert support Power supply(AC input) 100~250 Vac, 1.2 A, 60/50 Hz, universal • Automated process for status tracking Power consumption On: < 60 W, Off: < 8 W • Comprehensive service and support Power management DPMS compliant For details, visit: www.teklink.canvys.com Agency approval FCC, VCCI, CE Medical standard UL, CSA & TUV, GS ** For problems diagnosed prior to 4P.M. CST, advance replacements will ship the same day. Replacements for problems diagnosed after 4P.M. CST will ship the next business day. Specifications subject to change without notice. * Canvys may be able to custom program a matching signal to your legacy system based on the manufacturer, part number and/or system application. Please contact your Canvys representative to verify the compatibility of your timing’s requirements. • Tek-Chat (Online Chat) Comprehensive Technical Support Learn more at teklink.canvys.com • Search Knowledge Base Library • Real-Time Email Updates • Download Drivers and Manuals • 24/7 Phone and Web Services A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 18 Healthcare Surgical Imaging Color LCD A Division of Richardson Electronics 42” Image Systems FP4201-MED Because it has to be right • Full 1920 × 1080 2MP HD resolution • 700 cd/m² brightness • 3500:1 contrast ratio • Protective acrylic shield • EN/UL60601-1 certified • Includes AFS/CFS calibration package • IPX1 rated Medically Certified The Image Systems FP4201-MED large screen LCD is a medical grade display certified to EN/UL 60601 safety requirements for patient vicinity use. It features a unique, acrylic protective panel integrated and sealed into the bezel (IPX1-rated), which protects the screen and enables proper wipe-down and cleaning protocol. Integrated Features This 42” display utilizes full 1920 × 1080 HD resolution (2MP) and provides bright, clear images. The protective panel also guards against unintentional physical contact, maximizing each display’s long-term performance without compromising image quality. The panel’s anti-reflection surface also limits the glare of bright operating room lights. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 19 Healthcare Surgical Imaging Color LCD A Division of Richardson Electronics 42” Specifications & Features Series Model / Type Image Systems FP4201-MED Size 42” / 106.7 cm Active area (H × V) 930.24 × 523.26 mm (36.6” × 20.6”) Resolution 1920 × 1080 / HDTV @ 60 Hz Brightness 700 cd/m² typ. / 550 cd/m² min. Contrast ratio 3500:1 typ. Input signal 15 pin mini-D sub analog VGA, DVI-D (VGA analog + digital), S-Video, Composite video, Component video Control IR remote control, OSD Operating temperature / humidity 10 °C to +40 °C / 30 % to 75 % RH (non-condensing) Storage temperature / humidity -20 °C to +60 °C / 10 % to 90 % RH (non-condensing) Power Supply AC 100-240 V 50/60 Hz Power consumption 250 W Power save mode 20 W Safety & immunity UL60601-1, CSA C22.2 NO. 601.1, FCC, ICES, CE (IEC/EN60601-1, EN60601-1-2), CISPR Warranty display 3-year warranty DICOM ® Compatible The Image Systems FP4201-MED can be calibrated to the DICOM ® 3.14 standard for proper presentation of medical images. Backlight stabilization circuitry maintains SPECS & FEATURES the luminance for consistent images. Each FP4201-MED includes as standard the Image Systems Add-on Front Sensor (AFS) and Calibration Feedback System (CFS) software for automatic, hands-free calibration which is useful in hard to access operating rooms. Multi-Use Design Related Accessories The Image Systems FP4201-MED • Custom mounting: fixed or mobile Display leads the way in large screen • Computer solutions display technology designed specifi cally • Custom engineering for use in surgical suites, operating rooms, • Peripheral equipment endoscopy suites, cath labs, emergency rooms and other specialty areas where viewing images on a large screen display is advantageous. Hot Swap Optional Extended Warranty & Advance Replacement Program Learn more at teklink.canvys.com With the Canvys Hot Swap premium warranty service, customers can rest assured that the defective parts or products will be replaced within 24 hours* • Tek-Chat (Online Chat) • Minimize down time - Maximize productivity • Search Knowledge Base Library • Direct access to expert support • Real-Time Email Updates • Automated process for status tracking • Download Drivers and Manuals • Comprehensive service and support • 24/7 Phone and Web Services For details, visit: www.teklink.canvys.com Comprehensive Technical Support * For problems diagnosed prior to 4P.M. CST, advance replacements will ship the same day. Replacements for problems diagnosed after 4P.M. CST will ship the next business day. Specifications subject to change without notice. Large screen mobile cart mounting option A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 20 Healthcare Patient Monitoring Color LCD A Division of Richardson Electronics Medical Modality LCDs - Patient Monitoring Series 15” 19” Because it has to be right • Medically certified • Fully supports 1024 × 512 resolutions • Available in 15” and 19” • Integrated speakers • Industry standard beige • Compatibility allows for cost-effective upgrade Canvys offers a medically certified plug and play LCD series that is specifically designed to meet evolving patient needs in a fast-paced medical environment. These display solutions can be customized with a number of features such as; embedded protective shields or touch screen. These displays allow you to enhance the quality of care throughout your medical facility. The Canvys patient monitor solution is also a cost effective upgrade to existing OEM Patient Monitoring and Modality systems. We understand that replacing or upgrading LCDs and CRTs in medical environments can often be challenging and confusing for many end users. The Canvys experts are available to consult and design the perfect solution to meet your patient and department needs. In addition, these displays are backed by best-in-class service and support. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 21 Healthcare Patient Monitoring Color LCD A Division of Richardson Electronics 15” SPECS & FEATURES Specifications & Features Series Model / Type Patient Monitor Series ROM550AM Patient Monitor Series GOV950AM LCD size 15” / 38.1 cm 19” / 48.3 cm VESA standard resolution 1024 × 768 1280 × 1024 Custom resolutions 1024 × 512 1024 × 512 Pixel pitch 0.297 mm 0.294 mm Brightness (typ.) 250 cd/m² 300 cd/m² Contrast ratio (typ.) 400:1 1000:1 Response time (typ.) 16 ms 20 ms Viewable area 304.1 × 228.1 mm 396.3 × 301.0 mm Viewing angle (H × V) ± 60° / ± 60° ± 89° / ± 89° Colour depth 16.770 M 16.770 M Input signal Analog / DVI-D Analog / DVI-D Input connector 15 pin D-Sub / DVI-D 15 pin D-Sub / DVI-D Power supply input (external) 100 - 240 V @ 50/60 Hz 100 - 250 V @ 60/50 Hz Power supply output (external) 12 V / 3.0 A max. 12 V / 5.0 A max. Power consumption 27 W 60 W Tilt stand included included Dimensions with stand (H × W × D) 365 × 375 × 210 mm 467 × 432 × 251 mm VESA mounting 75 mm 100 mm Gross weight 5.3 kg 9.94 kg Speakers integrated integrated Shield * Yes – protective or acrylic Yes – protective or acrylic Optional Resistive touch Resistive touch Enclosure colour options beige beige Certifications UL/CSA 60950-1 UL/CSA 60601-1 CE, FCC-B UL/CSA 60950-1 UL/CSA 60601-1 CE, FCC-B 19” *Products do not come without shield. Canvys Patient Monitor Series compatible with: • GE Solar 8000, 8000M, 9500 • Spacelabs 1500, 1700 • Philips Viridian base M1097 Comprehensive Technical Support Learn more at teklink.canvys.com Detailed technical specifications available upon request. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 22 Healthcare Diagnostic & Clinical Review Grayscale LCD A Division of Richardson Electronics 3 MP DOME Grayscale LCD 5 MP Because it has to be right • 5-year warranty • 10-year backlight warranty • DICOM® calibration • 100 × 100 VESA mounting plate • 510(K) certified NDSsi, a leader in medical visualization, understands that in order to maximize the value and benefits of PACS, a modern hospital or imaging center needs the highest-quality, highest-resolution medical displays to meet the diverse requirements of doctors and staff. In fact, the end result of PACS technology is ultimately a function of how well and how accurately those vital digital images can be displayed and diagnosed. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 23 Healthcare Diagnostic & Clinical Review Grayscale LCD A Division of Richardson Electronics 3 MP Specifications & Features 5 MP DOME Grayscale LCD Model / Type Size SPECS & FEATURES Supported by DOME CXtra™ Software to ensure DICOM ® conformance NDSsi addresses this strong imaging need by manufacturing the DOME brand of diagnostic and clinical displays. The DOME brand has been synonymous with PACS for many years, introducing many firsts into the PACS market. E5 20.8” 21.3” Resolution 1536 × 2048 2048 × 2560 Brightness 800 cd/m² max. 750 cd/m² typ. Default Calibration Contrast 500 cd/m² 700:1 800:1 Viewing Angle H/V 170°/170° Weight w/o Stand 14 lbs Weight w/ Stand 22 lbs Mounting Options 100 × 100 mm VESA Power Input Power Consumption In 1999 DOME introduced the first DICOM ® calibration system for Flat panel displays. In 2000 Dome was the first to market with a 3 megapixel grayscale flat panel display. E3 Operating Range 100 to 240 V AC 50-60 Hz 60 W typ., 72 W max. Approvals Safety & Emissions 55 W typ., 72 W max. +10 °C to 40 °C +10 °C to 35 °C 510(K) CSAus, EN60601-1, FCC, CE, CCC, TUV-GM, VCCI, KCC Enviromental RoHS, WEEE, REACH In 2001 DOME introduced the first 5 megapixel grayscale flat panel, and… DICOM® LUT 3061 shades of gray …in 2004 were the first to receive FDA 510(k) clearance for flat-panel display use in mammography. NDSsi has a proven track record for understanding radiology needs, and delivering the highest quality and most reliable imaging systems to the market. Pixel Pitch Response Time Technology Video Input VGA Compatibility USB Interface Warranty The DOME EX and GX line of displays, along with DOME’s various software solutions, bring a wide range of imaging and software options to the PACS clinical imaging marketplace. Backlighlt Warranty 35 ms typ. 50 ms typ. 206 um, 123 dpi 165 um, 154 dpi TFT AMLCD Dual Domain IPS Dual Link DVI-D 640 × 480 to 1280 × 1024 built-in USB 2.0 Hub on stand 5-Year standard 10-Year standard DICOM ® calibration performed by DOME CXtra™ using the RightLight™ internal photometer and automatically maintained for the life of the display. DICOM ® conformance maintained by RightLight™ internal photometer. Independent conformance testing using DOME CXtra™ with an external photometer. E3 Dual Head System A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 24 E5 Dual Head System Healthcare Diagnostic & Clinical Review Color LCD A Division of Richardson Electronics 2 MP DOME Color LCD 3 MP 4 MP Because it has to be right • TFT AMLCD dual domain IPS • 5-year warranty • DICOM® calibration • 100 × 100 VESA mounting plate • 510(K) certified NDSsi, a leader in medical visualization, understands that in order to maximize the value and benefits of PACS, a modern hospital or imaging center needs the highest-quality, highest-resolution medical displays to meet the diverse requirements of doctors and staff. In fact, the end result of PACS technology is ultimately a function of how well and how accurately those vital digital images can be displayed and diagnosed. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 25 Healthcare Diagnostic & Clinical Review Color LCD A Division of Richardson Electronics 2 MP Specifications & Features 3 MP 4 MP DOME Color LCD Model / Type E2CHB E3CHB 19.6” 21.3” 30” Resolution 1200 × 1600 1536 × 2048 2560 × 1600 Brightness 800 cd/m² typ. 700 cd/m² typ. 330 cd/m² typ. SPECS & FEATURES Size NDSsi addresses this strong imaging need by manufacturing the DOME brand of diagnostic and clinical displays. The DOME brand has been synonymous with PACS for many years, introducing many firsts into the PACS market. Default Calibration In 1999 DOME introduced the first DICOM ® calibration system for Flat panel displays. In 2000 Dome was the first to market with a 3 megapixel grayscale flat panel display. Mounting Options In 2001 DOME introduced the first 5 megapixel grayscale flat panel, and… Contrast The DOME EX and GX line of displays, along with DOME’s various software solutions, bring a wide range of imaging and software options to the PACS clinical imaging marketplace. 12 lbs 15 lbs 20 lbs 23 lbs Power Consumption Operating Range Pixel Pitch DICOM ® conformance maintained by RightLight™ internal photometer. Independent conformance testing using DOME CXtra™ with an external photometer. 100 to 240 V AC 60 W typ., 90 W max. 96 W typ., 108 W max. 105 W typ., 130 W max. 0 °C to 35 °C +10 °C to 35 °C 0 °C to 35 °C 510(K) CSAus, EN60601-1, FCC, CE, CCC, TUV-GM, VCCI, KCC CSA, EN60601-1, FCC, CE, CCC, TUV-GM, VCCI, KCC, SEMKO 1786 shades of gray 50 ms typ. 24 ms typ. 16 ms typ. 249 um, 102 dpi 211 um, 120 dpi 250 um, 102 dpi TFT AMLCD Dual Domain IPS DVI-D DVI Revision 1.0 digital dual-link 640 × 480 to 1280 × 1024 640 × 480 to 1280 × 800 Video Input built-in USB 2.0 Hub on stand built-in USB 1.1 Hub Warranty 5-Year standard Backlighlt Warranty 5-Year standard A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 26 CSA, EN60601-1, FCC, CE, CCC, TUV-GM, VCCI,MIC,BSMI,C-Tick, SEMKO RoHS, WEEE, REACH 2041 shades of gray Technology USB Interface 36 lbs 100 × 200 mm VESA 100 to 240 V AC 50-60 Hz Enviromental Response Time 28 lbs 100 × 100 mm VESA Approvals DICOM® LUT 600:1 170°/170° Weight w/ Stand VGA Compatibility DICOM ® calibration performed by DOME CXtra™ using the RightLight™ internal photometer and automatically maintained for the life of the display. 300 cd/m² 750:1 Weight w/o Stand Safety & Emissions …in 2004 were the first to receive FDA 510(k) clearance for flat-panel display use in mammography. NDSsi has a proven track record for understanding radiology needs, and delivering the highest quality and most reliable imaging systems to the market. 500 cd/m² 700:1 Viewing Angle H/V Power Input E4C NA Healthcare Diagnostic & Clinical Review EIZO LCD A Division of Richardson Electronics 3 MP EIZO RadiForce® 5 MP Because it has to be right • Color and monochrome LCD • 5-year warranty • Diagnostic precision w/ DICOM® Part 14 • Backlight sensor • RadiCS & RadiNet Pro Worldwide, more and more hospitals are rapidly moving towards a filmless environment and medical image display monitors are becoming increasingly important. Hospital demands for monitor performance must vary according to where the monitor is used and what it is used for. Therefore, EIZO offers a wide range of monitor solutions to meet the medical imaging demands of hospitals. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 27 Healthcare Diagnostic & Clinical Review EIZO LCD A Division of Richardson Electronics 3 MP Specifications & Features 5 MP EIZO RadiForce® Model / Type RX-320-BK GS320-BK Size 21.3” Resolution Brightness Brightness Calibration SPECS & FEATURES Contrast 1536 × 2048 2048 × 2560 900 cd/m² typ. 1000 cd/m² typ. 700 cd/m² typ. 400 cd/m² 450 cd/m² 500 cd/m² 1000:1 850:1 800:1 Viewing Angle H/V RadiForce ® G&R-Series specially designed 1, 2, 3, 4, 5 and 10 megapixel monochrome and color monitors take full account of medical institutions’ need for different types of monitors with DICOM ® Part 14 standard calibration and high-performance capabilities required for confident diagnosis. Managing the quality of monitors used every day leads to the improvement of the quality of medical care itself. With filmless imaging spreading in the medical world, there is a growing interest in maintaining the quality of monitors displaying medical images. With the know-how and experience as a specialist in monitor manufacturing, we offer state-of-the-art solutions for the quality control of monitors which will lead to the improvement of the quality of medical care itself. • • • • Response Time Pixel Pitch 170°/170° 20 ms 23 ms typ. 50 ms 0.21075 × 0.21075 mm 0.2115 × 0.2115 mm 0.165 × 0.165 mm Input Signal 100 × 100 mm VESA USB Ports 1 up, 2 down Power Requirements AC 100- 120 V, 200-240 V:50/60 Hz 110 W, Power Save Mode < 3 W Sensor Panel DVI-D 24 Pin ×1 Display Port ×1 DVI Standard 1.0 Mounting Power Consumption < 3W 100 W, Power Save Mode < 1 W Backlight Sensor TFT Color LCD Panel (IPS) Warranty TFT Monochrome LCD Panel (IPS) 5-Year Warranty EN60601-1, CSA C22.2, No.601.1, EN60601-1-2 limit B, FCC Class A, MPR II CE, TUV/GM, cTUVus, UL60601-1CSA, CB, VCCI-B, FCC-B, C-Tick, 510K EN60601-1, CSA, UL60601-1-2 limit B, FCC Class A Grayscale Tones – 1024 from a palette of 8,161 4095 from a palette of 13,771 Weight w/ Stand 10.4 kg 9.9 kg 10.1 kg 7.4 kg 6.9 kg 7.1 kg Approvals Weight w/o Stand Quality Control Software RadiCS Network QC Management Software RadiNET Pro A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 28 GS521-CL-BK Healthcare Diagnostic & Clinical Review Color - 4MP A Division of Richardson Electronics Canvys Medical Imaging Displays: NEC MultiSync® MD304MC 30” Because it has to be right As a longtime provider of display solutions for the healthcare market, Canvys has the expertise to deliver medical imaging and advanced display systems your staff needs. We specialize in creating comprehensive solutions for diagnostic and clinical review, 3-D and post processing, surgical suites and modality-specific applications. In order to deliver the right solution, Canvys offers other best in class brands such as NEC. In addition, our technical services teams are imaging experts allowing us to trouble shoot, offer advance replacement and support any brand of display solution that you purchase from Canvys. This customerfocused approach is just one of the many reasons companies choose to work with us. Our complete healthcare services include: • On-site facility audits to determine your unique needs • Custom engineering and system integration • Hardware installation • Management and maintenance of your system throughout its lifecycle • Component hot-swapping • On-site user training and calibration A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 29 Healthcare Diagnostic & Clinical Review Color - 4MP A Division of Richardson Electronics 30” Specifications & Features Achieve complete color and Model / Type MultiSync® MD304MC brightness uniformity. By nature, LCD panels and CCFL backlights contain uniformity errors, or mura, which are visible as slightly brighter or darker areas on the screen. Display To combat this inherent trait, each MultiSync ® MD304MC display is individually characterized during 29.8” / 75.7 cm pixel pitch 0.25 mm pixels per inch 101 brightness (typ.) 200 cd/m² calibrated | 350 cd/m² max contrast ratio (typ.) 1000:1 viewing angle (typ.) 178° vert., 178° hor. (89U/89D/89L/89R) @ CR > 10 response time (typ.) Rapid Response™ (6 ms Gray-to-Gray; 12 ms Black-to-Black) panel bit depth production using a fully automated 12-bit internal LUTs, displays 16.7 million colors out of 68.5 billion color palette and 256 shades of gray out of 4096 coverage AdobeRGB - 97.8 % | sRGB - 100 % size AdobeRGB - 108 % | sRGB - 145.7 % horizontal 24 ~ 93.8 kHz (Analog/Digital) vertical 24 ~ 85 Hz are used to build a 3-D correction video bandwidth 25.2 ~ 268.5 MHz (DualLink) matrix stored inside the display. video Analog RGB 0.7 Vp-p / 75 Ω system that measures hundreds of Color gamut points across the screen at different gray levels. These measurements SPECS & FEATURES viewable size image This data is used to compensate for Synchronization range Separate sync: TTL Level (positive / negative) Input signal sync the uniformity not only as a function Composite sync: TTL Level (positive / negative) Composite sync on green: (0.3 Vp-p negative 0.7 Vp-p positive) of position on the screen but of gray Inputs DVI-D (HDCP), DVI-I level as well. In turn, this technology, Native resolution 2560 × 1600 @ 60 Hz landscape | 1600 × 2560 @ 60 Hz portrait called ColorComp™, reduces the non- Voltage rating uniformity to virtually unnoticeable Power consumption on 143 W (typ.) power savings mode 1.3 W Dimensions net (with stand) 27.1 × 18.8 - 26.3 × 13.5 in. | 687.3 × 478.6 - 668.6 × 342.8 mm (W × H × D) net (without stand) 27.1 × 17.6 × 5 in. | 687.3 × 446.8 × 126 mm with stand 42 lbs. | 19.2 kg without stand 31.7 lbs. | 14.4 kg levels and applies a digital correction to each pixel on the screen to compensate AC 100-120 V | AC 220-240 V for differences in color and luminance. Net weight VESA hole configuration specifications 100 × 100 mm and 200 × 100 mm operating temperature 5 to 35 °C | 41 to 95 °F operating humidity 30 to 80 % Environmental operating altitude 3048 m | 10,000 ft. conditions storage temperature -10 to 60 °C | 14 to 140 °F storage humidity 10 to 85 % storage altitude 12,192 m | 40,000 ft. UL/C-UL, UL60601-1, CE, Gost/PCT, PSB, CCC, TUV GS, FCC Class B/Canadian DOC, C-tick, MPR II / MPR III, VCCI (class 2), JIS C 61000-3-2, static electricity guideline, Safety standards low emission guideline, TUV-Ergonomie, ISO9241-307, TCO ‘03, TCO ‘6, US Mercury regulations, WEEE, RoHs, SASO, Energy Star 4.0 Tier 2, GEEA, JEITA VOC Guideline. J-Moss, Windows XP, DEN-TORI, FDA 510(k) Canvys also understands that the health Comprehensive Technical Support Learn more at teklink.canvys.com of your patients depends on flawlessly performing systems. That’s why we offer you expert support through TekLink ® , our professional services group. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 30 Healthcare Diagnostic & Clinical Review Grayscale and Color A Division of Richardson Electronics Canvys Medical Imaging Displays: NEC MultiSync® MD Series 20” 21” 30” Because it has to be right As a longtime provider of display solutions for the healthcare market, Canvys has the expertise to deliver medical imaging and advanced display systems your staff needs. We specialize in creating comprehensive solutions for diagnostic and clinical review, 3-D and post processing, surgical suites and modality-specific applications. In order to deliver the right solution, Canvys offers other best in class brands such as NEC. In addition, our technical services teams are imaging experts allowing us to trouble shoot, offer advance replacement and support any brand of display solution that you purchase from Canvys. This customerfocused approach is just one of the many reasons companies choose to work with us. Our complete healthcare services include: • On-site facility audits to determine your unique needs • Custom engineering and system integration • Hardware installation • Management and maintenance of your system throughout its lifecycle • Component hot-swapping • On-site user training and calibration A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 31 Healthcare Diagnostic & Clinical Review Grayscale and Color A Division of Richardson Electronics 20” Specifications & Features Model / Type MultiSync® MD212MC viewable size image pixel pitch pixels per inch MultiSync® MD213MC MultiSync® MD213MG 21.3” / 54,10 cm 21” MultiSync® MD304MC MultiSync® MD205MG 29.8” / 75.7 cm 20.1” / 51.05 cm 0.156 mm 0.27 mm 0.21 mm 0.251 mm 94 120 101 163 400 cd/m² calibrated 400 cd/m² calibrated 400 cd/m² calibrated 200 cd/m² calibrated 400 cd/m² calibrated 850 cd/m² max 800 cd/m² max 1450 cd/m² max 350 cd/m² max 850 cd/m² max 1050:1 750:1 900:1 1000:1 600:1 178° vert., 178° hor. 170° vert., 170° hor. (89U/89D/89L/89R) @ CR > 10 (85U/85D/85L/85R) Rapid Response™ (6 ms GtG) 30 ms 30” brightness (typ.) contrast ratio (typ.) Display viewing angle (typ.) response time (typ.) 176° vert., 176° hor. (88U/88D/88L/88R) @ CR > 10 Rapid Response™ (20 ms GtG) Rapid Response™ (12 ms GtG) 12-bit internal LUTs, displays 12-bit internal LUTs, displays up 12-bit internal LUTs, displays 16.7 million colors out of 68.5 billion panel bit depth 16.7 million colors out of 68.5 11.5-bit: 1024 shades of gray billion color palette and 256 from a pallet of 3061 to 1024 shades of gray out of color palette and 256 shades of gray out of 4096 4096 shades of gray out of 4096 Inputs DVI-D, DVI-I and VGA 15-pin D-sub Image stabilization DVI-D and DVI-I Tri-stimulus front sensor DVI-D (HDCP), DVI-I Front sensor DVI-D Backlight sensor 1600 × 1200 @ 60 Hz landscape 2048 × 1536 @ 60 Hz landscape 2560 × 1600 @ 60 Hz landscape 1200 × 1600 @ 60 Hz portrait 1536 × 2048 @ 60 Hz portrait 1600 × 2560 @ 60 Hz portrait 2560 × 2048 landscape SPECS & FEATURES Native resolution AC 100-120 V 2048 × 2560 portrait Internal, AC 100-240 V, Voltage rating AC 220-240 V Power consumption (typ.): on 100 W power savings mode 50/60 Hz nominal 105 W 100 W 2W 143 W 65 W 1.3 W <3W 18.7 × 18.3 × 9.7 in. Dimen- 18.4 × 17.1 - 23 × 12 in. 27.1 × 18.8 - 26.3 × 13.5 in. 467.8 × 434.3 - 584.3 × 306 mm 687.3 × 478.6 - 668.6 × 342.8 mm net (with stand) 474.3 × 465.3 × 247.3 mm (landscape) sions (W × H × D) 14.9 × 20.2 × 9.7 in. 18.4 × 14.2 × 4.4 in. 27.1 × 17.6 × 5 in. 467.8 × 361.6 × 110.7 mm 687.3 × 446.8 × 126 mm 23.5 lbs. | 10.7 kg 42 lbs. | 19.2 kg net (without stand) 379.6 × 512.7 × 247.3 mm (portrait) Net with stand weight without stand VESA hole configuration spec. operating temperature Environ- 25.8 lbs. | 9.8 kg 16.5 lbs. | 7.5 kg 31.7 lbs. | 14.4 kg NA 100 × 100 mm 100 × 100 and 200 × 100 mm 100 × 100 mm 5 to 35 °C | 41 to 95 °F operating humidity 10 to 40 °C | 50 to 104 °F 30 to 80 % operating altitude 3000 m | 9,842 ft. 3048 m | 10,000 ft. mental conditions storage temperature -10 to 60 °C | 14 to 140 °F storage humidity 10 to 85 % storage altitude Safety standards 10 to 95 % 12,192 m | 40,000 ft. UL/C-UL, UL60601-1, UL/C-UL, UL60601-1, UL/C-UL, UL60601-1, UL/C-UL, UL60601-1, CE, Gost/PCT, PSB, CCC, FCC Gost/PCT, PSB, CCC, FCC Gost/PCT, PSB, CCC, FCC Gost/PCT, PSB, CCC, TUV FCC part 15 class B, Class B/Canadian DOC, Class B/Canadian DOC, Class B/Canadian DOC, GS, FCC Class B/Canadian CE/MDD, PCT, C-tick, C-tick, MPR II / MPR III, C-tick, MPR II / MPR III, C-tick, MPR II / MPR III, DOC, C-tick, MPR II / MPR PCBC/B Mark, PSB, VCCI (class 2), JIS C VCCI (class 2), JIS C VCCI (class 2), JIS C III, VCCI (class 2), JIS C EnergyStar, GEEA Energy 61000-3-2, static electricity 61000-3-2, static electricity 61000-3-2, static electricity 61000-3-2, static electricity Label, DIN 6868-57, FDA guideline, low emission guideline, low emission guideline, low emission guideline, low emission 510K for mammography guideline, TUV-Ergonomie, guideline, US Mercury guideline, ISO9241-307, guideline, TUV-Ergonomie, ISO9241-307, US Mercury US Mercury regulations, regulations, WEEE, RoHs, US Mercury regulations, WEEE, RoHs, SASO, Energy SASO, Energy Star, J-Moss, WEEE, RoHs, SASO, Energy regulations, WEEE, RoHs, Star 4.0 Tier 2, JEITA VOC FDA 510k, CE-MDD, IRAM, Star, J-Moss, FDA 510k, SASO, Energy Star 4.0 Tier Guideline. J-Moss, FDA TUV GM, EPEAT, CE-MDD, IRAM, TUV GM, 2, GEEA, JEITA VOC 510k, CE-MDD Class 1, AAPM-TG-18, EPEAT, AAPM-TG-18, Guideline. J-Moss, Windows DIN V 6868-587 DIN V 6868-587 (Germany) XP, DEN-TORI, FDA 510k (Germany) CATB CATB AAPM-TG18 A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 32 UL2601/EN60601-1/EC601, Healthcare Diagnostic & Clinical Review Medical Display Bundles A Division of Richardson Electronics Canvys DICOM® Calibrated Mobile Workstation Solution for Healthcare Mobile access to DICOM® compliant images is important for today’s Radiologist. As a longtime provider of display solutions to for healthcare market, Canvys now proudly offers the world’s first DICOM® 3.14 calibrated diagnostic imaging laptop. HP’s new mobile workstation platform utilizing DreamColor 2 display technology integrated with Canvys’ proprietary Image Systems CFS calibration software allows radiologists access to DICOM® compliant images anywhere and at anytime. A ruggedized, high performance HP workstation in a laptop configuration combined with a DICOM® calibrated display delivers the optimal mobile solution. HP Mobile Workstation and Image Systems CFS Calibration Software • HP DreamColor 2 LED-backlit display technology • Available in 15.6” (8540W) and 17” (8740W) versions • Onboard NVIDIA Quadro FX Series graphics engine • Ruggedized to meet MIL-STD 810G testing • Image Systems CFS enables calibration to DICOM® 3.14 standard • DisplayPort DVI output connector and optional docking station on laptop allows for DICOM® calibration of external Image Systems Display(s) A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 33 Healthcare Diagnostic & Clinical Review Medical Display Bundles A Division of Richardson Electronics HP Mobile Workstation + Image Systems CFS Model / Type 8540W-CFS and 8740W-CFS Mobile Workstations Operating System Genuine Windows 7 Professional 64 bit (opt. 32 bit) Processor Intel® Core™ i7-720 QM /1.60 GHz (Quad Core) with Turbo Boost up to 2.8 GHz Chipset Mobile Intel® QM57 Chipset Memory 6 MB L3 cache RAM 8 GB 1333 MHz DDR3 SDRAM (4D) Hard Drive 500 GB 7200 rpm SATA 2.5 HDD Optical Storage DVD+/-RW SuperMulti with Double Layer Lightscribe Drive SPECS & FEATURES Display 8540W: 15.6” LED-backlit FHD DreamColor 2 (1920 × 1080) Antiglare w/camera 8740W: 17.0” LED-backlit WUXGA DreamColor 2 (1920 × 1200) Antiglare w/camera Graphics NVIDIA Quadro FX Series (880M/1 GB DDR3, 5000M/2 GB DDR3, or other) Wireless Support HP Integrated Module with Bluetooth(tm symbol) 2.1, Intel® Centrino™ Ultimate- N 6300 (3×3) Communications 56K v.92 high speed modem Input Device Full-sized keyboard with drains; touchpad and pointstick; integrated fingerprint reader Dimensions (W×D×H) 8540W: 373 × 251 × 33 mm | 8740W: 398 × 287 × 38 mm Power 8 Cell lithium ion 73 Whr with 1 year warranty Expansion Solutions Optional HP Docking Stations Specs subject to change. HP M OBILE W ORKSTATION + I MAGE S YSTEMS CFS The HP 8540W or 8740W gives users workstation caliber graphics and processing power in a laptop configuration. Image Systems CFS calibration software establishes DICOM ® conformance of the Dreamcolor 2 display for diagnostic or clinical use. This CFS enabled HP mobile workstation also allows for DICOM ® calibration of an external Image Systems 2MP or 3MP diagnostic color or grayscale medical grade LCD(s). This configuration of laptop and external diagnostic display provides a cost effective read workstation solution for home or office. 5 year Standard Warranty Hot Swap * * 5 year standard warranty hotswap on Image Systems displays. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 34 Healthcare Calibration Software CFS™ WebSuite A Division of Richardson Electronics CFS™ WebSuite Because it has to be right • Automatic hands-free calibration and conformance to DICOM® and AAPM TG18 standards • Remote monitoring and control of enterprise wide deployed displays via a web browser • Remote access, status updates and control of deployed displays via a handheld mobile device (Blackberry®, iPhone & iPad) CFS™ supports retractable front screen sensor • Generates Fleet Reports and log files for a verifiable record of activity and compliance • No ongoing subscription fees and minimal user intervention required For the last 20 years, Image Systems (Canvys’ CFS™ Local/Web calibration software is included private label Healthcare brand) has been recognized as with every Image Systems branded display bundle. an industry-leading display brand by consistently Image Systems CFS™ WebSuite calibration providing the highest quality diagnostic and clinical package now offers administrators unparalleled display solutions to the healthcare industry. access, flexibility and mobility in monitoring their deployed displays. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 35 Healthcare Calibration Software CFS™ WebSuite A Division of Richardson Electronics The Image Systems Advantage with CFS™ CFS™ WebSuite is comprised of three web based modules that work together to give administrators hands-free DICOM® conformance and QA of medical imaging displays. FEATURES CFS™ W EB S UITE CFS™ Local/Web (included with every Image Systems display CFS™ MobileManager bundle) … is the gold standard in medical imaging calibration. … is the first ever DICOM® calibration software enabling administrators Gathering data on each display from 4 points of reference access to their deployed displays via a handheld mobile device (backlight sensor, front-of-screen luminance sensor, ambient light (Blackberry®, iPhone & iPad). Administrators can rest easy, knowing and temperature sensors) gives the most detailed picture possible they hold the power of CFS MobileManager in their hand. of display performance in the industry today. All three components of CFS™ WebSuite work together to give administrators a complete snapshot in time of the status of all deployed displays. Mobile access to this data allows them to address CFS™ WebManager issues immediately and insure all medical imaging displays are in … enables remote monitoring access to enterprise wide displays via a conformance at all times. Best of all, data can be compiled in web browser eliminating the need for expensive 3rd party additional “Fleet Reports” or log formats providing a detailed verifiable record software packages. Detailed information about a display’s status can of compliance for each individual display. be viewed, administrators are notified with alerts of non-conformance, and displays can be re-calibrated from a remote administrator’s workstation. “Imag Discover the Canvys advantage of the Image Systems CFS WebSuite - e Sy s t em s CFS ™ has been t a do ubt on e of o heavil ur mo y relie st d upo n tools ensur for ing co mplian ce to practic the be es out st lined by DI AAPM COM ® TG18”, and noted Dr. Ra su Sh restha MD, MBA– Medic al Dire c t or, Digita l Imag ing In forma tics at UPMC withou http://www.canvys.com/cfswebsuite.html A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 36 36 Healthcare Diagnostic & Clinical Review Medical Display Bundles A Division of Richardson Electronics Image Systems Medical Display Bundles Because it has to be right As a longtime provider of display solutions for the healthcare market, Canvys has the expertise to deliver medical imaging and advanced display systems your staff needs. We specialize in creating comprehensive solutions for diagnostic and clinical review, 3-D and post processing, surgical suites and modality-specific applications. Plus, all of our solutions meet the most critical agency certifications and calibration standards for patient monitoring, bio-medical displays, ultrasound, cardiac imaging and PACS. Our healthcare services include: • On-site facility audits to determine your unique needs • Custom engineering and system integration • Hardware installation • Management and maintenance of your system throughout its lifecycle • Component hot-swapping • On-site user training and calibration Canvys also understands that the health of your patients depends on flawlessly performing systems. That’s why we offer you expert support through TekLink, our professional services group. Display and Accessories Partners Canvys is committed to understanding your visual technology needs and delivering a healthcare display solution that exceeds your expectations. In order to deliver the right solution, Canvys offers other best in class brands such as HP and NVIDIA®. In addition, our technical services teams are imaging experts allowing us to troubleshoot, offer advance replacement and support any brand of display solution that you purchase from Canvys. This customer-focused approach is just one of the many reasons companies choose to work with us. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 37 Healthcare Diagnostic & Clinical Review Medical Display Bundles A Division of Richardson Electronics Bundle Information 5 year Standard Warranty Hot Swap I MAGE S YSTEMS M EDICAL D ISPLAYS At the core of Canvys’ Healthcare Display Solutions is our private label brand of Image Systems diagnostic and clinical imaging LCDs. Image Systems has been recognized as an industryleading display brand for the last 20 years by consistently providing the highest quality diagnostic and clinical display solutions to the healthcare industry. A critical component of every Image Systems display bundle is our proprietary Calibration Feedback Software (CFS™). Our CFS™ calibration software is specifically designed to simplify the conformance and calibration of all Image Systems diagnostic and clinical use displays ensuring they maintain DICOM ® compliance and are properly calibrated throughout their life-cycle. Products: 2MP Gray | 2MP High Bright Color | Image Systems 3MP Gray | BUNDLE INFORMATION 3MP Color High Bright | 5MP Gray PC - HP Z800 W ORKSTATION Combining ultimate performance with a revolutionary new industrial design, the HP Z800 Workstation delivers the extreme speed and massive expandability that you demand to tackle your biggest challenges. Designed for speed, inside and out, the HP Z800 revolutionizes workstation industrial design. Featuring brushed aluminum side panels, integrated handles, visually cable-less engineering that maximizes airflow, modular component removal and reconnect, and optional liquid cooling. • HP Z800 Intel Xeon E5620/2.40 GHz QC 4 GB RAM 320 GB HDD 16× DVD R/W Win7 Pro 32bit. 3/3/3 parts/labor/NBD on site service and 24×7 TekLink Support. Includes all integration prior to delivery. G RAPHICS C ARD – NVIDIA ® Q UADRO ® 2000D AND NVS™ 300 Review high-resolution, detailed patient imagery and make a confident diagnosis faster with the NVIDIA ® Quadro ® 2000D – the industry’s most advanced diagnostic imaging graphics solution. Delivering best-in-class performance, two dual-link DVI connectors for display flexibility, support for 10/12bit grayscale monitors up to 10Mpixels, and DICOM ® monitor calibration capabilities – the Quadro ® 2000D enables more confident medical analysis. The NVIDIA ® NVS™ 300 high resolution, multi-display business graphics solution, designed for small and standard form factor systems, delivers reliable hardware and software for a stable business environment. Tested on leading business applications, NVS™ 300 is capable of driving two VGA, single link DVI, DisplayPort or HDMI displays. With NVIDIA ® Mosaic™ and NVIDIA ® nView ® technologies built in, you can span and efficiently manage your entire Windows desktop across multiple displays. A Division of Richardson Electronics | www.canvys.com /healthcare | 888.735.7373 38 Canvys On-Site Services QC/QA A Division of Richardson Electronics Canvys Quality Control & Quality Assurance Services Because it has to be right Canvys offers Quality Control and Quality Assurance TekLink ® QC/QA follows the DICOM Part 14 and AAPM services for your entire fleet of medical imaging TG18 guidelines to make sure your displays meet or monitors. The QC/QA on-site service program is ideal exceed those requirements. At the conclusion of each for facilities without the expertise or resources to QC/QA visit, you will receive documentation that can be maintain the conformance and calibration of multiple presented to all safety organizations. medical displays. Service Details Our TekLink ® The cost of the Canvys QC/QA service is based on the support personnel will visit your total number of workstations. Customers also have the facilities and perform a complete QC/QA testing option of purchasing our QC/QA Expert Service and and maintenance program, including: Training Package. This enhanced option offers not only • Testing and reporting to AAPM TG18 plug-ins a one-time QC/QA audit, but supplemental training and provided by the display manufacturer education to allow your team “to become the experts” • Internet-based web reports that can be viewed at a secured website from any computer • Workstation and display cleaning • Calibration software updates • Free annual calibration of external light meters* • DICOM Part 14 conformance checks • Annual DICOM Calibration** • Applicable Engineering Revisions * Each meter will always have a traceability standard back and implement a display calibration and conformance program. This premium training package includes access to superior technical support via our Teklink ® service portal and a dedicated support engineer. Please contact your Canvys Sales Representative for pricing. ** Some display systems cannot be field calibrated. to N.I.S.T. A Division of Richardson Electronics | http://teklink.canvys.com | 800.235.2125 39 Canvys On-Site Services QC/QA A Division of Richardson Electronics Deliverables After TekLink QC/QA service has been completed the “TekLink has allowed us to site administrator will receive an emailed report for each create an optimal QC/ QA workstation serviced. The email will consist of worksta- program…one we feel tion data,calibration reports, verified visual tests, adheres to our industry’s and other available calibration parameters such as: most stringent conformance guidelines. We’ve • DICOM Compliance • Luminance Uniformity the costs, man-hours, and • LUM & FIT Values overall complexity of • Peak Brightness • Black Level • Contrast Ratio been able to greatly reduce performing this critical function.” Enterprise Imaging Project Manager Proof of Dicom part 3.14 calibration is supplied by either graphical or numerical supplied data sets. Reports and graphical calibration will be sent via email. Reports and graphical calibration will be sent via email. A Division of Richardson Electronics | http://teklink.canvys.com | 800.235.2125 40 Canvys Service & Support Hot Swap A Division of Richardson Electronics Canvys Hot Swap - Extended Warranty & Advance Replacement Program Because it has to be right • Minimize down time - Maximize productivity Hot Swap • Direct access to expert support • 24/ 7 online and phone support • Automated process for status tracking • Comprehensive service and support At Canvys, our superb product quality reflects our commitment to excellence. We realize that occasionally hardware components can fail. With the Canvys Hot Swap premium warranty service, customers can rest assured that the defective parts or products will be replaced within 24 hours*. We understand not all businesses are alike and in many instances, daily display solution performance is critical to the success of the company. Therefore extended downtime can not be tolerated. The Canvys Hot Swap Advance Replacement Program was designed as a coverage plan for our customers to manage through these rare occasions. To ensure your business runs smoothly, this advance replacement program also extends the standard warranty on select products. In addition, Canvys offers an onsite service option on specific displays. Please contact a Canvys Expert for more information. Standard in-warranty repair claims could take weeks for a replacement and sometimes longer. *For problems diagnosed prior to 4P.M. CST, advance replacements will ship the same day. Replacements for problems diagnosed after 4P.M. CST will ship the next business day. Specifications subject to change without notice. A Division of Richardson Electronics | http://teklink.canvys.com | 800.235.2125 41 Canvys Service & Support Hot Swap A Division of Richardson Electronics Canvys Hot Swap - Extended Warranty and Advance Replacement Program Terms & Conditions dependent upon product availability from the manufacturer. Process Description wiring and connections, (2) unauthorized modifications, Customer must immediately return the unserviceable part alterations, repairs or repair personnel, or (3) use in any tem or component failures. If necessary, we will ship out a or component (the “Returned Product”) to Canvys for eval- combinations not approved in the manufacturer’s specifi- replacement the same day or following morning. To begin to uation and final disposition. The Returned Product must be take advantage of the rapid replacement, please report the shipped in the same packaging as the advance replace- issue via the Canvys TekLink Service and Support Portal ment product and include the Return Authorization Num- source external to the Covered Product, including, but not (http://teklink.canvys.com). Once your issue has been logged ber clearly legible on the outside of the packaging. limited to, general environmental conditions, negligence, Failure to return the Returned Product to Canvys within 14 misuse, abuse, vandalism, spilling of liquid on the Covered • Upon receipt of the advance replacement ment product and a return material authorization (RMA) days will result in Customer being billed the Manufacturer’s number. Shipping instructions will be given to return the failed Suggested List Price or Canvys List Price, at Canvys’ dis- unit to one of our service locations. cretion, for the Returned Product. In addition, Customer will be denied access to Advanced Product Replace- cations; • Loss or damage caused by any physical force from a Product, or acts of God; • Loss or damage to the Covered Product either while in storage or in the course of transit, delivery, or redelivery; • Normal maintenance, cleaning, or tune-ups; minor adjust- Terms and Conditions ment/Hot Swap Guarantee coverage for the Covered ments and settings outlined in the Covered Product These terms and conditions govern the Extended Warranty Products until the invoice has been paid or the Returned owner’s manual that the user can perform; costs related to and Advance Product Replacement/Hot Swap Guarantee Product has been returned to Canvys. any service request which results in customer education or Canvys will incur the freight charges for all advance no replacement products and will assume responsibility for including, but not limited to, (1) loss of brightness over (this “Warranty”) offered by Canvys, a division of Richardson • Electronics, Ltd. (“Canvys”). TERMS AND CONDITIONS Damages or costs resulting from (1) improper electrical properly diagnose and determine the root cause for the sys- you will be given an estimated arrival time for your replace- • • product, Upon receipt of the failed system the Canvys team will problem found; screen imperfections, freight charges for the return of Returned Products to the time caused by degradation of phosphors (backlight 1. Coverage Canvys location providing service and support. In the degradation), or (2) image burn-in or burned phosphor This Warranty covers only products for which Customer has event that Canvys determines, in its sole discretion, that a caused by prolonged display of one or more signals (image purchased an Extended Warranty and Advanced Product Returned Product is not eligible for Warranty coverage, burn); except with respect to backlight degradation to the Replacement/Hot Swap Guarantee from Canvys (“Covered Canvys shall so notify Customer. If Customer desires to extent covered by the manufacturer’s original warranty Products”). This Warranty does not replace the manufactur- return the advance replacement product, Customer will and solely during the term of the manufacturer’s original er’s warranty, but provides certain additional benefits during reimburse Canvys for all related transportation costs, and the term of the manufacturer’s warranty. After the manufac- Canvys will return the Returned Product to Customer, at turer’s warranty expires, this Warranty continues to provide Customer’s cost. If Customer desires to retain the service agreement, insurance policy or manufacturer recall the benefits of the manufacturer’s warranty, subject to the advance replacement product, Customer will be invoiced in effect at the time of the failure. terms and conditions thereof, as well as certain additional for benefits listed in this Warranty. This Warranty begins on the repair parts and repair fees for the Returned Product. In 6. Limitation of Liability date of purchase, as stated on the invoice for the Covered addition, charge The total payment of all combined claims under this Warranty Product, and continues for thirty-six (36) months. Image Customer a fee not to exceed $325.00 for evaluation of shall not exceed the original purchase price of the Covered Systems products warranty valid for sixty (60) months. Returned Product found to be ineligible for Warranty Products excluding shipping, handling and taxes. If Canvys coverage. determines that a Covered Product cannot be repaired, Prior to the expiration of the manufacturer’s warranty, Canvys will replace it with a new or remanufactured product If a Covered Product does not conform to the original Canvys will manage all warranty issues directly with the of like kind and quality. At Canvys’ option, replacement parts manufacturer’s manufacturer of the Covered Product on Customer’s will be new, remanufactured, or non-original manufacturer’s behalf. parts that perform to the factory specifications of the original • 2. Claim Procedure • warranty, Customer may call the appropriate Canvys District Sales Manager, call Canvys be Canvys reach a the Canvys freight right Field charges, to part. If a Covered Product is replaced with a new product, this Warranty is considered fulfilled and coverage ends with page are PM CST will be sent to our automated paging system and respect to that Covered Product. If a Covered Product is strongly encouraged to report any service issues via the will be returned by the On-Call Field Applications Engineer repaired or replaced with a remanufactured product, coverage Canvys TekLink Internet Support web page. This service immediately. will continue until the end of the original coverage period. Customers may reserves for Engineer via TekLink 24 x 7 x 365. Calls placed after 5:00 http://teklink.canvys.com. Customers responsible Repair or replacement covered by any other warranty, the issue via the Canvys TekLink Internet Support web at • and warranty; • Applications TekLink Support & Service at (800) 235-2125, or report negates the need for a phone call and accurately logs all • information provided to ensure a prompt and efficient 3. Availability of Services 7. Transferability response to your support needs. While Canvys tries to complete service as quickly as possible, This Warranty is not transferable and is valid for the original Once the service issue has been confirmed, a Canvys Field Canvys is not responsible for delays caused by factors beyond purchaser of Covered Products only. Applications Engineer or Product Manager must approve all its control, including, but not limited to, manufacturer’s advance replacement/hot swap requests. delays, product availability, parts availability, or acts of God. • Once approved, and subject to product availability, • This Warranty is exclusive. The sole and exclusive obligation 4. Customer Responsibilities of Canvys shall be to repair or replace the defective Covered 32” (diagonal) in size will be shipped same day via Customer must follow the instructions in the owner’s manual Products in the manner and for the period provided above. overnight delivery from our Plymouth, MN facility for for proper use, care and maintenance of a Covered Product. Canvys shall not have any other obligation with respect to the calls received prior to 4:00 PM CST and from our Marl- Failure to follow the manufacturer’s maintenance and service Covered Products or any part thereof, whether based on boro, MA facility for calls received prior to 2:00 PM EST, recommendations may result in the denial of coverage under contract, tort, strict liability or otherwise. Under no circum- and the following day for all calls received after the this Warranty. stances, whether based on this Warranty or otherwise, shall Canvys be liable for incidental, special or consequential Once approved, and subject to product availability, 5. Exclusions damages. If any part of this Warranty is determined to be void advance replacement products required that are 32” This Warranty does not cover any of the following conditions, or illegal, the remainder shall remain in full force and (diagonal) and over in size will be shipped same day via in addition to any exclusions in the manufacturer’s original effect. 2nd day delivery from our Plymouth, MN facility for calls warranty: EXPRESSLY received prior to 4:00 PM CST and from our Marlboro, • THE WARRANTIES IN LIEU OF IN AND THIS WARRANTY EXCLUDE ALL ARE OTHER Covered Products whose serial number has been altered or WARRANTIES, EXPRESS AND/OR IMPLIED INCLUDING BUT removed; NOT LIMITED TO WARRANTIES OF MERCHANTABILITY AND Cosmetic defects or failure of non-operational components OF FITNESS FOR A PARTICULAR PURPOSE, USE OR APPLICA- that do not inhibit the proper operation and performance of TION AND ALL OTHER OBLIGATIONS OR LIABILITIES ON THE In the event that advance replacement products are not the Covered Product, such as cracked cases or broken PART OF CANVYS, UNLESS SUCH OTHER WARRANTIES, immediately available, Canvys will supply the advance hinges; OBLIGATIONS OR LIABILITIES ARE EXPRESSLY AGREED TO MA facility for calls received prior to 2:00 PM EST, and the following day for all calls received after the aforementioned cutoff times. • 8. Exclusive Obligation advance replacement products required that are under aforementioned cutoff times. replacement products in as timely a manner as possible, • IN WRITING BY CANVYS. A Division of Richardson Electronics | http://teklink.canvys.com | 800.235.2125 42 monitor © 2011 Canvys • A Division of Richardson Electronics, Ltd. • All rights reserved. Product names and logos are registered trademarks or trademarks of their respective holders. All trademarks acknowledged. Due to technical changes or a change in the location at which the products are manufactured, the products delivered can differ slightly from those described and depicted in this catalog. Despite our having taken the greatest possible care in editing the catalog, factual and printing errors cannot be excluded. For the above reasons, solely the information in our offer and / or our order confirmation is definitive. We carry out orders on the basis of our ‘General Terms and Conditions of Delivery and Payment’ valid at the time of the order. The current version of these conditions can be seen and downloaded here http://www.canvys.com/terms-of-sale.html.