topjob ® s
Transcription
topjob ® s
TOPJOB® The Rail-Mounted Terminal Block System 1 The range of rail-mounted terminal blocks for a perfect electrical installation Largest portfolio of rail-mounted terminal blocks 4 TOPJOB®S technology 6 Smallest to the largest 8 smartPRINTERTM by WAGO 10 TOPJOB®S jumper system 12 XCOM®S pluggable system 14 Special function terminal blocks 16 TOPJOB®S benefits at a glance 18 Rail-mounted terminal blocks 16 AWG / 1.0 (1.5) mm2 20 Rail-mounted terminal blocks 14 AWG / 1.5 (2.5) mm2 21 Rail-mounted terminal blocks 12 AWG / 2.5 (4) mm 23 Rail-mounted terminal blocks 10 AWG / 4 (6) mm2 24 Rail-mounted terminal blocks 8 AWG / 6 (10) mm2 25 2 Rail-mounted terminal blocks 6 AWG / 10 (16) mm2 26 Rail-mounted terminal blocks 4 AWG / 16 (25 "f-st") mm2 27 35° Rail-mounted terminal blocks 12 AWG / 2.5 (4) mm2 28 Test plug adapter and testing tap, push-in type wire jumpers, motor configuration jumpers 29 Vertical jumpers, colored jumpers, endless jumpers 30 Modular connectors 31 Double deck terminal blocks 16 AWG / 1 (1.5) mm 35 2 Double deck terminal blocks 12 AWG / 2.5 (4) mm2 37 Double deck terminal blocks: 4 conductors per deck 39 Triple deck terminal blocks 12 AWG / 2.5 (4) mm 40 2 Motor terminal blocks 12 AWG / 2.5 (4) mm241 Disconnect terminal blocks for test and measurement 12 AWG / 2.5 (4) mm2 44 Double deck disconnect terminal blocks for test and measurement 12 AWG / 2.5 (4) mm2 47, 54 Fuse terminal blocks 12 AWG / 2.5 (4) mm 48 2 Double deck fuse and disconnect blocks 12 AWG / 2.5 (4) mm254 Disconnect terminal blocks for test and measurement 8 AWG / 6 (10) mm257 Fuse terminal blocks 8 AWG / 6 (10) mm260 Plug-in component modules 66 Diode and LED terminal blocks 14 AWG / 1.5 (2.5) mm272 Diode and LED terminal blocks 12 AWG / 2.5 (4) mm273 Double deck diode and LED terminal blocks 12 AWG / 2.5 (4) mm2 74 Triple deck diode and LED terminal blocks 12 AWG / 2.5 (4) mm2 76 X-COM®S terminal blocks 16 AWG / 1.0 (1.5) mm2 80 X-COM S terminal blocks 12 AWG / 2.5 (4) mm 86 ® Oversized end plates/separators 2 92 Mounting accessories and stickers for operating instructions93 Ferrules and crimping tools94 Marking of terminal blocks96 List of approvals102 4 The Industry‘s Largest Portfolio for Industrial, Process and Transportation Applications Industry‘s widest range of conductor sizes: 24 AWG - 350 kcmil (0.14–185 mm2) Comprehensive range of feed-through and special function terminal blocks Connect all conductor types 5 TOPJOB®S – Vibration-Proof, WAGO – The Spring Pressur Simply pushed in! Simple, push-in termination of solid and ferruled conductors – no operating tool needed Save time! Reduce wiring time by up to 75% Always reliable! Just like the original CAGE CLAMP® (patented in 1977), TOPJOB®S with CAGE CLAMP®S ensures reliability with spring pressure connection technology that automatically adjusts for environmental influences such as temperature cycling and vibration 6 , Fast, Maintenance-Free e Connection Technology What does this mean for you? • Maintenance-free connections – wire it once and forget it • Wiring independent of operator skill – no torque values or special tools needed • Eliminate service calls due to loose connections • Corrosion-resistant, gas-tight connections for corrosive atmospheres Both hands free for faster wiring! CAGE CLAMP®S for all conductor types Simple, push-in termination of solid and ferruled conductors Once inserted, the operating tool holds the spring open allowing the use of both hands for wiring 7 POWER CAGE CLAMP® • The industry’s first and only spring pressure terminal block for 350 kcmil • See www.wago.us/powercageclamp.htm 8 The Smallest, the Biggest and Always the Right Terminal Blocks The Smallest • Maximizes cabinet space • Up to 16 AWG (1.5 mm2) at 600V/10A The Biggest • Wire size up to 350 kcmil (185 mm2) • Terminate large conductors with a single turn • 8 - 2 AWG (35 mm2) up to 600V/115A • 8 AWG – 2/0 (50 mm2) up to 600V/150A • 4 AWG – 4/0 (95 mm2) up to 600V/200A • 1/0 - 350 kcmil (185 mm2) up to 1000V/310A And In Between • Including feed-through, ground, double deck, triple deck, pluggable, fuse, disconnect, LED and diode terminal blocks Industry‘s widest range of spring pressure terminal blocks For conductor sizes 24 AWG – 350 kcmil (0.14-185 mm2) Save additional space with the use of multi-level terminal blocks (up to 66%) 9 smartPRINTERTM by WAGO – The Fastest and Most Efficient Marking System • Print on both strip and tag style terminal block markers; as well as wire markers, push button plates and adhesive labels • Multi-line marking capable – more detail means less wiring errors • Clear, smudge free thermal printing – no drying time • All marking material on continuous reel – reduces reload for faster marking • Mark up to 9,615 terminal blocks on a single reel 10 Industry exclusive continuous marker strip with multi-line marking One system for all marking requirements: components, wire marking, etc. Printing software integrated in “free of charge” ProServe engineering tool Watch us go from 0 to 100 in 10 seconds: www.smartprinter.us/video 11 TOPJOB®S Jumper System Ready to Solve Any Commoning Tasks WAGO’s range of jumpers provide the greatest possibilities and convenience: Multi-pole, push-in jumpers can be easily customized by removing a single contact leg (factory preconfigured jumpers also available). Unique solutions include Delta or Wye motor wiring. Push-In Type Jumper Bars Jumper Retention Spring 12 Endless jumpers for endless possibilities. This two position adjacent jumper takes up only jumper slot and allows continuous commoning – no limits. Adjacent Jumpers for Continuous Commoning Our step-down jumpers easily common terminal blocks rated for different conductors sizes (e.g. POWER CAGE CLAMP® rated 8 - 2 AWG to TOPJOB®S Series 2010 rated 20 - 6 AWG). Resulting in a cost saving and modular approach for power distribution applications. Step-Down Jumper Using push-in type wire jumpers, commoning over longer distances, across multiple levels, or around plug-in component accessories is easily achieved. Slim style jumpers are similar to our standard multi-pole jumpers, except they are thinner to accommodate alternate commoning within a single jumper slot row, offering an industry best commoning of up to 4 different potentials. The perfect solution for multi-level terminal blocks: Vertical jumpers easily connect two or three levels within a single terminal block. Vertical Jumper Slim Style Jumper Push-In Type Wire Jumper Exclusive jumper retention spring – ensures reliable commoning Comprehensive jumper system for virtually any application Minimum two jumper slots on every terminal block Simple, easy to use push-in design 13 X-COM®S and TOPJOB®S Create Synergies X-COM®S: Pluggable Connector System for Modular Rail-Mounted Terminal Blocks Benefits of Pre-harnessed Assemblies: • Connectorize your test fixture…plug-in, test, un-plug and ship • Fast and error free wiring during equipment dismantle and assembly • Cost effective alternative to rectangular connectors Features of X-COM®S: • Protection against accidental contact in the un-mated condition • Coding provides protection against mis-mating • Marking on both connector and terminal block for fast reliable connections • Industry’s first and only 3.5mm wide pluggable rail mounted terminal block 14 Common profile makes X-COM®S and TOPJOB®S compatible for: •Commoning •Marking Benefit from pre-harnessed assemblies Protection against accidental contact Coding provides additional safety 15 Comprehensive Range of Sp For Application Specific Sol Disconnect Terminal Blocks • Isolation of a circuit for test and measurement of a signal • Plug-in and knife pivot disconnect versions • Available in single and multi-level terminal blocks Easy self-assembly of component plugs Wide variety of function terminal blocks Disconnect terminal block up to 1,000 V (e.g., photovoltaic applications) 16 ecial Function Terminal Blocks – utions Component Plugs for Self-Assembly • Creation of a custom circuit containing diode, LED, resistor, etc. • Single and multi-level carrier terminal blocks to accept component plugs • Component plugs also available for plug-in to the existing jumper slot of terminal blocks Fuse Terminal Blocks • Protection of a circuit • Plug-in and pivot style fuse terminal blocks for glass fuses (5 x 20mm and ¼ x 1¼) and auto style fuses • Available in single and multi-level terminal blocks with and without blown fuse indication Diode and LED Terminal Blocks • Polarity protection and status indication of a circuit • Available in single and multi-level terminal blocks • Custom solutions available – contact factory 17 Benefits at a Glance 18 The Industry‘s Largest Portfolio for Industrial, Process and Transportation Applications Industry‘s widest range of conductor sizes: 24 AWG - 350 kcmil (0.14–185 mm2) Comprehensive range of feed-through and special function terminal blocks Connect all conductor types TOPJOB®S – Vibration-Proof, Fast, Maintenance-Free WAGO – The Spring Pressure Connection Technology CAGE CLAMP®S for all conductor types Simple, push-in termination of solid and ferruled conductors Once inserted, the operating tool holds the spring open allowing the use of both hands for wiring The Smallest, the Biggest and Always the Right Terminal Blocks Industry‘s widest range of spring pressure terminal blocks For conductor sizes 24 AWG – 350 kcmil (0.14-185 mm2) Save additional space with the use of multi-level terminal blocks (up to 66%) smartPRINTERTM by WAGO – The Fastest and Most Efficient Marking System Industry exclusive continuous marker strip with multi-line marking One system for all marking requirements: components, wire marking, etc. Printing software integrated in “free of charge” ProServe engineering tool TOPJOB®S Jumper System Ready to Solve Any Commoning Tasks Exclusive jumper retention spring – ensures reliable commoning Comprehensive jumper system for virtually any application Minimum two jumper slots on every terminal block Simple, easy to use push-in design X-COM®S and TOPJOB®S Create Synergies Benefit from pre-harnessed assemblies Protection against accidental contact Coding provides additional safety Comprehensive Range of Special Function Terminal Blocks – For ApplicationsSpecific Solutions Easy self-assembly of component plugs Wide variety of function terminal blocks Disconnect terminal block up to 1,000 V (e.g., photovoltaic applications) 19 ? Rail-Mounted Terminal Blocks 1.0 (1.5) mm2/AWG 16 2000 Series 0.14–1.0(1.5) mm2 800 V/6 kV/3 IN 13.5 A (18 A) AWG 24 – 16 600 V, 10 A U 600 V, 10 A 2 Terminal block width 3.5 mm / 0.137 in L 9 – 11 mm / 0.39 in 0.14 –1.0( 1.5) mm2 800 V/6 kV/3 IN 13.5 A (18 A) AWG 24 – 16 600 V, 10 A U 600 V, 10 A 2 Terminal block width 3.5 mm / 0.137 in L 9 – 11 mm / 0.39 in 0.14 –1.0( 1.5) mm2 800 V/6 kV/3 IN 13.5 A (18 A) AWG 24 – 16 600 V, 10 A U 600 V, 10 A 2 Terminal block width 3.5 mm / 0.137 in L 9 – 11 mm / 0.39 in <____ 48.5 mm /1.91 in ____> ItemPack.-unit No.pcs 4 4 4 4 4 4 2-conductor through terminal blocks 2000-1201 gray blue 2000-1204 2 2000-1202 orange red 2000-1203 black 2000-1205 yellow 2000-1206 4 2-conductor ground (earth) terminal block 2000-1207 green-yellow ItemPack.-unit No.pcs 4 4 4 4 4 4 100 100 100 100 100 100 3-conductor through terminal blocks 2000-1301 gray blue 2000-1304 2 2000-1302 orange red 2000-1303 black 2000-1305 yellow 2000-1306 100 3-conductor ground (earth) terminal block 2000-1307 green-yellow Suitable for Ex i applications <____________ 68 mm /2.67 in ____________> 4 ItemPack.-unit No.pcs 4 4 4 4 4 4 100 100 100 100 100 100 4-conductor through terminal blocks 2000-1401 gray blue 2000-1404 2 2000-1402 orange red 2000-1403 black 2000-1405 yellow 2000-1406 100 4-conductor ground (earth) terminal block 2000-1407 green-yellow 4 2 Suitable for Ex i applications 2 Suitable for Ex i applications Item-Specific Accessories Item-Specific Accessories Item-Specific Accessories End and intermediate plate, 0.7 mm thick orange 2000-1292100 (4 x 25) gray 2000-1291100 (4 x 25) End and intermediate plate, 0.7 mm thick orange 2000-1392100 (4 x 25) gray 2000-1391100 (4 x 25) 2000 Series Accessories Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Push-in type jumper bar, insulated, IN 14 A light gray 2-way 2000-402200 (8 x 25) 3-way 2000-403200 (8 x 25) 4-way 2000-404200 (8 x 25) 5-way 2000-405100 (4 x 25) 6-way 2000-406100 (4 x 25) 7-way 2000-407100 (4 x 25) 8-way 2000-408100 (4 x 25) 9-way 2000-409100 (4 x 25) 10-way 2000-410100 (4 x 25) Push-in type jumper bar, insulated, IN 14 A light gray from 1-3 2000-433200 (8 x 25) from 1-4 2000-434200 (8 x 25) from 1-5 2000-435100 (4 x 25) from 1-6 2000-436100 (4 x 25) from 1-7 2000-437100 (4 x 25) from 1-8 2000-438100 (4 x 25) from 1-9 2000-439100 (4 x 25) from 1-10 2000-440100 (4 x 25) Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2000-115 100 (4 x 25) Delta jumper, insulated, IN = IN terminal block, light gray 1-2 3-4 5-6 2000-406/020-000 100 (4 x 25) Star point jumper, insulated, IN = IN terminal block, light gray 1-3-52000-405/011-000 100 (4 x 25) Test plug adapter, for test plug 4 mm Ø 2009-174 100 (4 x 25) gray Testing tap, for max. 2.5 mm2 Banana plug, for socket 4 mm Ø color mixed 215-111 50 Testing tap, for max. 2.5 mm2 gray 2009-182 100 (4 x 25) Testing plug, with 500 mm cable, 2 mm Ø 210-136 50 red Testing plug, with 500 mm cable, 2.3 mm Ø 210-137 50 yellow 20 <_______ 59.5 mm /2.34 in ________> mm / <___ 33 1.3 in ___> mm / <___ 33 1.3 in ___> mm / <___ 33 1.3 in ___> 2000 Series terminal blocks can accomodate: 0.14mm2 (24 AWG) - 1.5mm2 (16 AWG) solid or stranded wire; or direct insertion of: 0.5mm2 (20 AWG) - 1.5mm2(16 AWG) solid or 0.5mm2 (20 AWG) - 0.75mm2 (18AWG) stranded wire with ferrule (10mm barrel length) 2 100 100 100 100 100 100 100 End and intermediate plate, 0.7 mm thick orange 2000-1492100 (4 x 25) gray 2000-1491100 (4 x 25) Marking strip, plain, 11 mm wide 50 m roll white 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, for 3.5 mm terminal block width plain 793-3501 5 ? Rail-Mounted Terminal Blocks 1.5 (2.5) mm2/AWG 14 2001 Series 2 0.25 –1.5 (2.5) mm AWG 22 – 14 800 V/8 kV/3 600 V, 15 A U 18 A 600 V, 15 A 2 Terminal block width 4.2 mm / 0.165 in L 9 – 11 mm / 0.39 in 0.25 –1.5 (2.5) mm2 AWG 22 – 14 800 V/8 kV/3 600 V, 15 A U 18 A 600 V, 15 A 2 Terminal block width 4.2 mm / 0.165 in L 9 – 11 mm / 0.39 in 2 0.25 –1.5 (2,5) mm AWG 22 – 14 800 V/8 kV/3 600 V, 15 A U 18 A 600 V, 15 A 2 Terminal block width 4.2 mm / 0.165 in L 9 – 11 mm / 0.39 in ItemPack.-unit No.pcs 4 4 4 4 4 4 2-conductor through terminal blocks 2001-1201 gray blue 2001-1204 2 2001-1202 orange red 2001-1203 black 2001-1205 yellow 2001-1206 100 100 100 100 100 100 4 <_______ 59.5 mm /2.34 in ________> ItemPack.-unit No.pcs 4 4 4 4 4 4 3-conductor through terminal blocks 2001-1301 gray blue 2001-1304 2 2001-1302 orange red 2001-1303 black 2001-1305 yellow 2001-1306 100 100 100 100 100 100 4 4 <_12 _> mm/ <___ 33 1.3 in ___> 4 <____ 48.5 mm /1.91 in ____> mm / <___ 33 1.3 in ___> 4 mm / <___ 33 1.3 in ___> 2001 Series terminal blocks can accomodate: 0.25mm2 (22 AWG) - 2.5mm2 (14 AWG) solid or stranded wire; or direct insertion of: 0.5mm2 (20 AWG) - 2.5mm2 (14 AWG) solid or 0.75mm2 (18 AWG) - 1.5mm2 (16AWG) stranded wire with ferrule (12mm barrel length) <____________ 70 mm /2.76 in ____________> ItemPack.-unit No.pcs 4 4 4 4 4 4 4-conductor through terminal blocks 2001-1401 gray blue 2001-1404 2 2001-1402 orange red 2001-1403 black 2001-1405 yellow 2001-1406 100 100 100 100 100 100 4 2-conductor ground (earth) terminal block 2001-1207 100 green-yellow Suitable for Ex e II applications 550 V, 17 A 2 Suitable for Ex i applications 3-conductor ground (earth) terminal block 2001-1307 100 green-yellow Suitable for Ex e II applications 550 V, 17 A 2 Suitable for Ex i applications 4-conductor ground (earth) terminal block 2001-1407 100 green-yellow Suitable for Ex e II applications 550 V, 17 A 2 Suitable for Ex i applications Item Specific Accessories Item Specific Accessories Item Specific Accessories End and intermediate plate, 0.8 mm /0.031 in thick orange 2002-1292100 (4 x 25) gray 2002-1291100 (4 x 25) End and intermediate plate, 0.8 mm /0.031 in thick orange 2002-1392100 (4 x 25) gray 2002-1391100 (4 x 25) End and intermediate plate, 0.8 mm /0.031 in thick orange 2002-1492100 (4 x 25) gray 2002-1491100 (4 x 25) 4 4 4 Oversized endplates and sperator plates on page 92 2001 Series Accessories Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Push-in type jumper bar, insulated, IN 18 A light gray 2-way 2001-402200 (8 x 25) 3-way 2001-403200 (8 x 25) 4-way 2001-404200 (8 x 25) 5-way 2001-405100 (4 x 25) 6-way 2001-406100 (4 x 25) 7-way 2001-407100 (4 x 25) 8-way 2001-408100 (4 x 25) 9-way 2001-409100 (4 x 25) 10-way 2001-410100 (4 x 25) Push-in type jumper bar, insulated, IN 18 A light gray from 1-3 2001-433200 (8 x 25) from 1-4 2001-434200 (8 x 25) from 1-5 2001-435100 (4 x 25) from 1-6 2001-436100 (4 x 25) from 1-7 2001-437100 (4 x 25) from 1-8 2001-438100 (4 x 25) from 1-9 2001-439100 (4 x 25) from 1-10 2001-440100 (4 x 25) Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2001-115 100 (4 x 25) Step-down jumper, insulated, IN 32 A light gray 2006-499 50 (2 x 25) Insulation stop, 5 pcs/strip, 0.25 - 0.5 mm2 light gray 2001-171200 (8 x 25) Test plug adapter, for test plug 4 mm Ø 2009-174 100 (4 x 25) gray Testing tap, for max. 2.5 mm2 Testing tap, for max. 2.5 mm2 gray 2009-182 100 (4 x 25) Testing plug, with 500 mm cable, 2 mm Ø 210-136 50 red Testing plug, with 500 mm cable, 2.3 mm Ø 210-137 50 yellow Marking strip, plain, 11 mm wide 50 m roll white 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, stretchable 4 - 4.2 mm plain 793-4501 5 WMB Inline, plain, stretchable 4 - 4.2mm, 2,000 WMB markers, 4mm, on roll white 2009-114 1 Modular TOPJOB®S connector, can be snapped together, for jumper contact slot gray 2001-511100 (4 x 25) Spacer module, can be snapped together, e.g., for bridging commoned terminal blocks gray 2001-549100 (4 x 25) End plate, for modular TOPJOB®S connectors, 1.5 mm thick gray 2002-541100 (4 x 25) 21 ? Double Potential Terminal Blocks 2000 Series 2001 Series <___________ 85.9 mm /3.38 in ____________> ItemPack.-unit No.pcs Double potential terminal block, both potentials can be commoned 2000-2141 gray 0.25 –1.5 (2.5) mm2 AWG 22 – 14 800 V/8 kV/3 600 V, 15 A U IN 18 A (24 A) 600 V, 15 A 2 Terminal block width 4.2 mm / 0.165 in L 9 – 11 mm / 0.39 in <____________ 70 mm /2.76 in ____________> ItemPack.-unit No.pcs Double potential terminal block, 2001-1441 gray 100 mm / <___ 37.5 1.48 in ___> <____________ 70 mm /2.76 in ____________> ItemPack.-unit No.pcs Double potential terminal block, 2002-1441 gray 100 50 Attention! This double potential terminal block cannot be commoned with push-in type jumper bars! Attention! This double potential terminal block cannot be commoned with push-in type jumper bars! Accessories Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) End and intermediate plate, 0.7 mm thick orange 2000-2196100 (4 x 25) gray 2000-2195100 (4 x 25) End and intermediate plate, 0.8 mm /0.031 in thick orange 2002-1492100 (4 x 25) gray 2002-1491100 (4 x 25) 200 strips Insulation stop, 5 pcs/strip light gray2001-171 0.25-0.5 mm2 Double potential terminal blocks are space savers. Two independent through terminal blocks are placed in one insulated housing on one level. Input and output contacts of one circuit are placed on the same side of the terminal block. Both circuits can be individually marked according to input and output. 22 AWG 22 – 12 0.25 –1.5 (4) mm2 800 V/8 kV/3 600 V, 20 A U IN 24 A (32 A) 600 V, 20 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in mm / <___ 37.5 1.48 in ___> mm / <___ 32.5 1.28 in ___> 0.14–1(1.5) mm2 AWG 24 – 16 800 V/8 kV/3 IN 13.5 A (18 A) Terminal block width 3.5 mm / 0.138 in L 9 – 11 mm / 0.39 in 2002 Series End and intermediate plate, 0.8 mm /0.031 in thick orange 2002-1492100 (4 x 25) gray 2002-1491100 (4 x 25) 200 strips Insulation stop, 5 pcs/strip light gray2002-171 0.25-0.5 mm2 dark gray2002-172 0.75-1 mm2 Protective warning marker, for 5 terminal blocks yellow 2002-115100 (4 x 25) ? Rail-Mounted Terminal Blocks 2.5 (4) mm2/AWG 12 2002 Series 2 AWG 22 – 12 0.25 – 2.5 (4) mm 800 V/8 kV/3 600 V, 20 A U 24 A 600 V, 20 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in 0.25 – 2.5 (4) mm2 AWG 22 – 12 800 V/8 kV/3 600 V, 20 A U 24 A 600 V, 20 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in 0.25 – 2.5 (4) mm2 AWG 22 – 12 800 V/8 kV/3 600 V, 20 A U 24 A 600 V, 20 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in <____ 48.5 mm /1.91 in ____> ItemPack.-unit No.pcs <________ 59.5 mm /2.34‑in _________> 4 4 4 4 4 4 ItemPack.-unit No.pcs 4 <_____________ 70 mm /2.76 in _____________> 4 4 4 4 4 4 <_12 _> mm / <___ 33 1.3 in ___> 4 mm / <___ 33 1.3 in ___> 4 mm / <___ 33 1.3 in ___> 2002 Series terminal blocks can accomodate: 0.25mm2 (22 AWG) - 4mm2 (12 AWG) solid or stranded wire; or direct insertion of: 0.75mm2 (18 AWG) - 4mm2 (12 AWG) solid or 0.75mm2 (18 AWG) - 2.5mm2 (14 AWG) stranded wire with ferrule (12mm barrel length) ItemPack.-unit No.pcs 4 4 4 4 4 4 2-conductor through terminal blocks 3-conductor through terminal blocks 4-conductor through terminal blocks 2002-1201 100 gray 2002-1301 100 gray 2002-1401 100 gray blue 2002-1204 2 100 blue 2002-1304 2 100 blue 2002-1404 2 100 2002-1202 100 orange 2002-1302 100 orange 2002-1402 100 orange red 2002-1203 100 red 2002-1303 100 red 2002-1403 100 black 2002-1205 100 black 2002-1305 100 black 2002-1405 100 yellow 2002-1206 100 yellow 2002-1306 100 yellow 2002-1406 100 brown2002-1201/0000-0014 brown2002-1301/0000-0014 brown2002-1401/0000-0014 light gray2002-1209 100 light gray2002-1309 100 light gray2002-1409 100 2-conductor ground (earth) terminal block 3-conductor ground (earth) terminal block 4-conductor ground (earth) terminal block 2002-1207 100 green-yellow 2002-1307 100 green-yellow 2002-1407 100 green-yellow 2 Suitable for Ex e II applications 550 V, 22 A 2 Suitable for Ex e II applications 550 V, 22 A 2 Suitable for Ex e II applications 550 V, 22 A Suitable for Ex i applications Suitable for Ex i applications Suitable for Ex i applications 4 4 4 4 4 4 Item Specific Accessories Item Specific Accessories Item Specific Accessories End and intermediate plate, 0.8 mm /0.031 in thick orange 2002-1292100 (4 x 25) gray 2002-1291100 (4 x 25) End and intermediate plate, 0.8 mm /0.031 in thick orange 2002-1392100 (4 x 25) gray 2002-1391100 (4 x 25) End and intermediate plate, 0.8 mm /0.031 in thick orange 2002-1492100 (4 x 25) gray 2002-1491100 (4 x 25) Oversized endplates and sperator plates on page 92 2002 Series Accessories Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Push-in type jumper bar, insulated, IN 25 A light gray 2-way 2002-402200 (8 x 25) 3-way 2002-403200 (8 x 25) 4-way 2002-404200 (8 x 25) 5-way 2002-405100 (4 x 25) 6-way 2002-406100 (4 x 25) 7-way 2002-407100 (4 x 25) 8-way 2002-408100 (4 x 25) 9-way 2002-409100 (4 x 25) 10-way 2002-410100 (4 x 25) Push-in type jumper bar, insulated, IN 25 A light gray from 1-3 2002-433200 (8 x 25) from 1-4 2002-434200 (8 x 25) from 1-5 2002-435100 (4 x 25) from 1-6 2002-436100 (4 x 25) from 1-7 2002-437100 (4 x 25) from 1-8 2002-438100 (4 x 25) from 1-9 2002-439100 (4 x 25) from 1-10 2002-440100 (4 x 25) Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2002-115 100 (4 x 25) Slim style jumper, insulated, IN 25 A light gray 2-way 2002-472 200 (8 x 25) 3-way 2002-473 200 (8 x 25) 4-way 2002-474 200 (8 x 25) 5-way 2002-475 100 (4 x 25) : 12-way 2002-482 100 (4 x 25) Step-down jumper, insulated, IN 32 A light gray 2006-499 50 (2 x 25) Adjacent jumper for continuous commoning, insulate 1N 25 A light gray 2-way 2002-400100 (4 x 25) Insulation stop, 5 pcs/strip, 0.25 - 0.5 mm2 light gray 2002-171200 (8 x 25) 0.75 - 1 mm2 dark gray 2002-172200 (8 x 25) Test plug adapter, for test plug 4 mm Ø 2009-174 100 (4 x 25) gray Testing tap, for max. 2.5 mm2 gray 2009-182 100 (4 x 25) Marking strip, plain, 11 mm wide 50 m roll white 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 5 WMB Inline, plain, stretchable 5 - 5.2mm, 1,500 WMB markers, 5mm, on roll white 2009-115 1 Modular TOPJOB®S connector, for jumper contact slot gray 2002-511100 (4 x 25) Spacer module, gray 2002-549100 (4 x 25) End plate, for modular TOPJOB®S connectors, 1.5 mm thick gray 2002-541100 (4 x 25) 23 ? Rail-Mounted Terminal Blocks 4 (6) mm2/AWG 10 2004 Series 2 AWG 20 – 10 0.5 – 4 (6) mm 800 V/8 kV/3 600 V, 30 A U 32 A 600 V, 30 A 2 Terminal block width 6.2 mm / 0.244 in L 11 – 13 mm / 0.47 in 0.5 – 4 (6) mm2 AWG 20 – 10 800 V/8 kV/3 600 V, 30 A U 32 A 600 V, 30 A 2 Terminal block width 6.2 mm / 0.244 in L 11 – 13 mm / 0.47 in 0.5 – 4 (6) mm2 AWG 20 – 10 800 V/8 kV/3 600 V, 30 A U 32 A 600 V, 30 A 2 Terminal block width 6.2 mm / 0.244 in L 11 – 13 mm / 0.47 in ItemPack.-unit No.pcs <________ 65.5 mm /2.58 in ________> 4 4 4 4 4 4 ItemPack.-unit No.pcs 4 4 4 4 4 4 2-conductor through terminal blocks 2004-1201 50 gray blue 2004-1204 50 2 2004-1202 50 orange red 2004-1203 50 black 2004-1205 50 yellow 2004-1206 50 3-conductor through terminal blocks 2004-1301 50 gray blue 2004-1304 50 2 2004-1302 50 orange red 2004-1303 50 black 2004-1305 50 yellow 2004-1306 50 4 4 <_12 _> mm / <___ 33 1.3 in ___> 4 <____ 52.5 mm /2.07 in ____> mm / <___ 33 1.3 in ___> 4 mm / <___ 33 1.3 in ___> 2004 Series terminal blocks can accomodate: 0.5mm2 (20 AWG) - 6mm2 (10 AWG) solid or stranded wire; or direct insertion of: 1mm2 (18 AWG) - 6mm2 (10 AWG) solid or 0.75mm2 (18 AWG) - 4mm2 (12 AWG) stranded wire with ferrule (12mm barrel length) 4 <_____________ 79 mm /3.11 in _____________> ItemPack.-unit No.pcs 4 4 4 4 4 4 4-conductor through terminal blocks 2004-1401 50 gray blue 2004-1404 50 2 2004-1402 50 orange red 2004-1403 50 black 2004-1405 50 yellow 2004-1406 50 2-conductor ground (earth) terminal block 2004-1207 50 green-yellow Suitable for Ex e II applications 550 V, 30 A 3-conductor ground (earth) terminal block 2004-1307 50 green-yellow Suitable for Ex e II applications 550 V, 30 A 4-conductor ground (earth) terminal block 2004-1407 50 green-yellow Suitable for Ex e II applications 550 V, 30 A 2 Suitable for Ex i applications 2 Suitable for Ex i applications 2 Suitable for Ex i applications 4 4 4 Item Specific Accessories Item Specific Accessories Item Specific Accessories End and intermediate plate, 1 mm thick orange 2004-1292100 (4 x 25) gray 2004-1291100 (4 x 25) End and intermediate plate, 1 mm thick orange 2004-1392100 (4 x 25) gray 2004-1391100 (4 x 25) End and intermediate plate, 1 mm thick orange 2004-1492100 (4 x 25) gray 2004-1491100 (4 x 25) Oversized endplates and sperator plates on page 92 2004 Series Accessories Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Push-in type jumper bar, insulated, IN 32 A light gray 2-way 2004-402200 (8 x 25) 3-way 2004-403200 (8 x 25) 4-way 2004-404200 (8 x 25) 5-way 2004-405100 (4 x 25) 6-way 2004-406100 (4 x 25) 7-way 2004-407100 (4 x 25) 8-way 2004-408100 (4 x 25) 9-way 2004-409100 (4 x 25) 10-way 2004-410100 (4 x 25) Push-in type jumper bar, insulated, IN 32 A light gray from 1-3 2004-433200 (8 x 25) from 1-4 2004-434200 (8 x 25) from 1-5 2004-435100 (4 x 25) from 1-6 2004-436100 (4 x 25) from 1-7 2004-437100 (4 x 25) from 1-8 2004-438100 (4 x 25) from 1-9 2004-439100 (4 x 25) from 1-10 2004-440100 (4 x 25) Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2004-115 100 (4 x 25) Delta jumper, insulated, IN = IN terminal block, light gray 1-2 3-4 5-6 2004-406/020-000 100 (4 x 25) Star point jumper, insulated, IN = IN terminal block, light gray 1-3-52004-405/011-000 100 (4 x 25) Step-down jumper, insulated, IN 32 A light gray 2006-499 50 (2 x 25) Insulation stop, 5 pcs/strip, 0.25 - 0.5 mm2 light gray 2002-171200 (8 x 25) 0.75 - 1 mm2 dark gray 2002-172200 (8 x 25) Test plug adapter, for test plug 4 mm Ø 2009-174 100 (4 x 25) gray Testing tap, for max. 2.5 mm2 gray 2009-182 100 (4 x 25) 24 Marking strip, plain, 11 mm wide 50 m roll white 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 5 WMB Inline, plain, stretchable 5 - 5.2mm, 1,500 WMB markers, 5mm, on roll white 2009-115 1 Modular TOPJOB®S connector, for jumper contact slot gray 2004-511100 (4 x 25) Spacer module, gray 2004-549100 (4 x 25) ? Rail-Mounted Terminal Blocks 6 (10) mm2/AWG 8 2006 Series 0.5 – 6 (10) mm2 AWG 20 – 8 800 V/8 kV/3 600 V, 50 A U 41 A 600 V, 50 A 2 Terminal block width 7.5 mm / 0.295 in L 13 – 15 mm / 0.55 in 2 AWG 20 – 8 0.5 – 6 (10) mm 800 V/8 kV/3 600 V, 50 A U 41 A 600 V, 50 A 2 Terminal block width 7.5 mm / 0.295 in L 13 – 15 mm / 0.55 in Commoning with step-down jumpers Application notes see page 7 <_____ 57.5 mm /2.26 in ______> ItemPack.-unit No.pcs 2-conductor through terminal blocks 2006-1201 50 gray blue 2006-1204 50 2006-1202 50 orange 4 4 4 4 2-conductor ground (earth) terminal block 2006-1207 50 green-yellow Suitable for Ex e II applications 550 V, 38 A Suitable for Ex i applications 4 Item Specific Accessories End and intermediate plate, 1 mm thick orange 2006-1292100 (4 x 25) gray 2006-1291100 (4 x 25) 4 <____________ 73.5 mm /2.89 in ___________> ItemPack.-unit No.pcs 3-conductor through terminal blocks 2006-1301 25 gray blue 2006-1304 25 2006-1302 25 orange 4 4 4 4 3-conductor ground (earth) terminal block 2006-1307 25 green-yellow Suitable for Ex e II applications 550 V, 36 A Suitable for Ex i applications 4 <_12 _> mm / <___ 33 1.3 in ___> 4 mm / <___ 33 1.3 in ___> 2006 Series terminal blocks can accomodate: 0.5mm2 (20 AWG) - 10mm2 (8 AWG) solid or stranded wire; or direct insertion of: 1mm2 (18 AWG) - 10mm2 (8 AWG) solid or 1.5mm2 (16 AWG) - 6mm2 (10 AWG) stranded wire with ferrule (14mm barrel length) ItemPack.-unit No.pcs Commoning with step-down jumpers An end plate must always be used between the terminal blocks that are commoned with step-down jumpers. Step-down jumper 2006-499 is suitable for commoning series 2006 or 2004 terminal blocks with series 2002, 2001 or 2000 terminal blocks. Step-down jumpers are simply pushed down to full insertion, in the same way as all other push-in type jumper bars. Item Specific Accessories End and intermediate plate, 1 mm thick orange 2006-1392100 (4 x 25) gray 2006-1391100 (4 x 25) Step-down jumper, light gray, insulated 32 A 2006-499 50 (2 x 25) Oversized endplates and sperator plates on page 92 2006 Series Accessories Push-in type jumper bar, insulated, IN 41 A light gray 2-way 2006-402 50 (2 x 25) 3-way 2006-403 50 (2 x 25) 4-way 2006-404 50 (2 x 25) 5-way 2006-405 50 (2 x 25) Push-in type jumper bar, insulated, IN 41 A light gray from 1-3 2006-433 50 (2 x 25) from 1-4 2006-434 50 (2 x 25) from 1-5 2006-435 50 (2 x 25) Star point jumper, insulated, IN = IN terminal block, light gray 1-3-52006-405/011-000 50 (2 x 25) Step-down jumper, insulated, IN 32 A light gray 2006-499 50 (2 x 25) Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2006 -115 100 (4 x 25) Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Lockout cap, for conductor entry hole and operating slot gray 2006-19125 ® Modular TOPJOB S connector, can be snapped together, for jumper contact slot gray 2006-511 100 (4 x 25) Test plug adapter, for test plug 4 mm Ø 2009-174 100 (4 x 25) gray Testing tap, for max. 2.5 mm2 gray 2009-182 100 (4 x 25) Note: The total current flowing cannot exceed the rating of the step-down jumper/push-in type jumper bar. Marking strip, plain, 11 mm wide 50 m roll white 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 5 WMB Inline, plain, stretchable 5 - 5.2mm, 1,500 WMB markers, 5mm, on roll white 2009-115 1 25 ? Rail-Mounted Terminal Blocks 10 (16) mm2/AWG 6 2010 Series 2 AWG 20 – 6 0.5 – 10 (16) mm 800 V/8 kV/3 600 V, 65 A U 57 A 600 V, 65 A 2 Terminal block width 10 mm / 0.394 in L 17 – 19 mm / 0.71 in 2 AWG 20 – 6 0.5 – 10 (16) mm 800 V/8 kV/3 600 V, 65 A U 57 A 600 V, 65 A 2 Terminal block width 10 mm / 0.394 in L 17 – 19 mm / 0.71 in Commoning with step-down jumpers Application notes see page 7 <________ 68 mm /2.68 in _________> ItemPack.-unit No.pcs 4 4 4 2-conductor through terminal blocks 2010-1201 25 gray blue 2010-1204 25 2010-1202 25 orange 4 2-conductor ground (earth) terminal block 2010-1207 25 green-yellow Suitable for Ex e II applications 550 V, 51 A 4 Suitable for Ex i applications 4 <________ 89 mm /3.5 in _________> ItemPack.-unit No.pcs 4 4 4 3-conductor through terminal blocks gray 2010-1301 25 blue 2010-1304 25 orange 2010-1302 25 4 3-conductor ground (earth) terminal block green-yellow 2010-1307 25 Suitable for Ex e II applications 550 V, 50 A 4 Suitable for Ex i applications Item Specific Accessories Item Specific Accessories End and intermediate plate, 1 mm thick orange 2010-1292100 (4 x 25) gray 2010-1291100 (4 x 25) End and intermediate plate, 1 mm thick orange 2010-1392100 (4 x 25) gray 2010-1391100 (4 x 25) Oversized endplates and sperator plates on page 92 2010 Series Accessories Push-in type jumper bar, insulated, IN 57 A light gray 2-way 2010-402 50 (2 x 25) 3-way 2010-403 50 (2 x 25) 4-way 2010-404 50 (2 x 25) 5-way 2010-405 50 (2 x 25) Push-in type jumper bar, insulated, IN 57 A light gray from 1-3 2010-433 50 (2 x 25) from 1-4 2010-434 50 (2 x 25) from 1-5 2010-435 50 (2 x 25) Star point jumper, insulated, IN = IN terminal block, light gray 1-3-52010-405/011-000 50 (2 x 25) Step-down jumper, insulated, IN 57 A light gray 2016-499 50 (2 x 25) Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2010 -115 50 (8 x 25) 26 <_18 _> / <___ 37‑mm 1.46 in ___> 4 / <___ 37‑mm 1.46 in ___> 2010 Series terminal blocks can accomodate: 0.5mm2 (20 AWG) - 16mm2 (6 AWG) solid or stranded wire; or direct insertion of: 2.5mm2 (14 AWG) - 16mm2 (6 AWG) solid or 2.5mm2 (14 AWG) - 10mm2 (8 AWG) stranded wire with ferrule (18mm barrel length) Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Finger guard, touchproof cover protects unused conductor entries yellow 2010-100 100 (4 x 25) Modular TOPJOB®S connector, can be snapped together, for jumper contact slot gray 2010-511 50 (2 x 25) Test plug adapter, for test plug 4 mm Ø 2009-174 100 (4 x 25) gray Testing tap, for max. 2.5 mm2 gray 2009-182 100 (4 x 25) Marking strip, plain, 11 mm wide 50 m roll white 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 5 WMB Inline, plain, stretchable 5 - 5.2mm, 1,500 WMB markers, 5mm, on roll white 2009-115 1 ItemPack.-unit No.pcs Commoning with step-down jumpers An end plate must always be used between the terminal blocks that are commoned with step-down jumpers. Step-down jumper 2016-499 is suitable for commoning series 2016 or 2010 terminal blocks with series 2010, 2006, 2004 or 2002 terminal blocks. Step-down jumpers are simply pushed down to full insertion, in the same way as all other push-in type jumper bars. Step-down jumper, light gray, insulated 57 A 2016-499 50 (2 x 25) Note: The total current flowing cannot exceed the rating of the step-down jumper/push-in type jumper bar. Finger guard cover snapped into unused clamping unit (Example: Series 2016) ? Rail-Mounted Terminal Blocks 16 (25 ”f-st”) mm2/AWG 4 2016 Series 2 0.5 – 16 (25 „f“) mm AWG 20 – 4 800 V/8 kV/3 600 V, 85 A U 76 A 600 V, 85 A 2 Terminal block width 12 mm / 0.472 in L 18 – 20 mm / 0.75 in 2 0.5 – 16 (25 „f“) mm AWG 20 – 4 800 V/8 kV/3 600 V, 85 A U 76 A 600 V, 85 A 2 Terminal block width 12 mm / 0.472 in L 18 – 20 mm / 0.75 in Commoning with step-down jumpers Application notes see page 7 <___________ 70 mm /2.76 in _________> ItemPack.-unit No.pcs 2-conductor through terminal blocks 2016-1201 20 gray blue 2016-1204 20 orange 2016-1202 20 4 4 4 4 2-conductor ground (earth) terminal block 2016-1207 20 green-yellow Suitable for Ex e II applications 550 V, 70 A Suitable for Ex i applications 4 <_18 _> / <___ 37‑mm 1.46 in ___> 4 / <___ 37‑mm 1.46 in ___> 2016 Series terminal blocks can accomodate: 0.5mm2 (20 AWG) - 25mm2 (4 AWG) solid or stranded wire; or direct insertion of: 2.5mm2 (14 AWG) - 16mm2 (6 AWG) solid or 2.5mm2 (14 AWG) - 16mm2 (6 AWG) stranded wire with ferrule (18mm barrel length) 4 <___________ 92 mm /3.62 in _________> ItemPack.-unit No.pcs 3-conductor through terminal blocks gray 2016-1301 20 blue 2016-1304 20 orange 2016-1302 20 4 4 4 4 3-conductor ground (earth) terminal block green-yellow 2016-1307 20 Suitable for Ex e II applications 550 V, 67 A Suitable for Ex i applications 4 Item Specific Accessories Item Specific Accessories End and intermediate plate, 1 mm thick orange 2016-1292100 (4 x 25) gray 2016-1291100 (4 x 25) End and intermediate plate, 1 mm thick orange 2016-1392100 (4 x 25) gray 2016-1391100 (4 x 25) ItemPack.-unit No.pcs Commoning with step-down jumpers An end plate must always be used between the terminal blocks that are commoned with step-down jumpers. Step-down jumper 2016-499 is suitable for commoning series 2016 or 2010 terminal blocks with series 2010, 2006, 2004 or 2002 terminal blocks. Step-down jumpers are simply pushed down to full insertion, in the same way as all other push-in type jumper bars. Step-down jumper, light gray, insulated 57 A 2016-499 50 (2 x 25) Oversized endplates and sperator plates on page 92 2016 Series Accessories Push-in type jumper bar, insulated, IN 76 A light gray 2-way 2016-402 50 (2 x 25) 3-way 2016-403 50 (2 x 25) 4-way 2016-404 50 (2 x 25) 5-way 2016-405 50 (2 x 25) Push-in type jumper bar, insulated, IN 57 A light gray from 1-3 2016-433 50 (2 x 25) from 1-4 2016-434 50 (2 x 25) from 1-5 2016-435 50 (2 x 25) Star point jumper, insulated, IN = IN terminal block, light gray 1-3-52016-405/011-000 50 (2 x 25) Step-down jumper, insulated, IN 57 A light gray 2016-499 50 (2 x 25) Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2016 -115 50 (8 x 25) Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Finger guard, touchproof cover protects unused conductor entries yellow 2016-100 100 (4 x 25) Modular TOPJOB®S connector, can be snapped together, for jumper contact slot gray 2016-511 50 (2 x 25) Test plug adapter, for test plug 4 mm Ø 2009-174 100 (4 x 25) gray Testing tap, for max. 2.5 mm2 gray 2009-182 100 (4 x 25) Marking strip, plain, 11 mm wide 50 m roll white 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 5 WMB Inline, plain, stretchable 5 - 5.2mm, 1,500 WMB markers, 5mm, on roll white 2009-115 1 Note: The total current flowing cannot exceed the rating of the step-down jumper/push-in type jumper bar. Commoning from 35mm2/2 AWG POWER CAGE CLAMP® terminal blocks to 10/16mm2 (8/10 AWG) TOPJOB®S terminal blocks is available with 285-430 step-down jumper. 27 ? 3- and 4-Conductor Rail-Mounted Terminal Blocks 2.5 (4) mm2/AWG 12 2002Series 0.25 – 2.5 (4) mm2 AWG 22 – 12 800 V/8 kV/3 600 V, 20 A U 24 A 600 V, 20 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in 2 AWG 22 – 12 0.25 – 2.5 (4) mm 800 V/8 kV/3 600 V, 20 A U 24 A 600 V, 20 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in <_____ 52 mm /2.05 in _____> 4 4 4 4 4 4 3-conductor through terminal blocks gray 2002-6301 blue 2002-6304 2002-6302 orange red 2002-6303 2002-6305 black 2002-6306 yellow 3-conductor ground (earth) terminal block 2002-6307 green-yellow Suitable for Ex i applications 4 <_____ 52 mm /2.05 in _____> ItemPack.-unit No.pcs 100 100 100 100 100 100 100 Accessories 4 4 4 4 4 4 ItemPack.-unit No.pcs 4-conductor through terminal blocks gray 2002-6401 blue 2002-6404 2002-6402 orange red 2002-6403 2002-6405 black 2002-6406 yellow 4-conductor ground (earth) terminal block 2002-6407 green-yellow Suitable for Ex i applications 4 100 100 100 100 100 100 100 Attention! These terminal blocks cannot be commoned! Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) End and intermediate plate, 0.8 mm /0.031 in thick End and intermediate plate, 0.8 mm /0.031 in thick orange 2002-6392100 (4 x 25) orange 2002-6392100 (4 x 25) gray 2002-6391100 (4 x 25) gray 2002-6391100 (4 x 25) Oversized endplates and separator plates on page 92 Insulation stop, 5 pcs/strip 200 strips Push-in type jumper bars, light gray, insulated, IN 25 A 2-way 2002-402200 (8 x 25) 3-way 2002-403200 (8 x 25) light gray2002-171 0.25-0.5 mm2 dark gray2002-172 0.75-1 mm2 4-way 2002-404200 (8 x 25) 5-way 2002-405100 (4 x 25) Protective warning marker, : : for 5 terminal blocks yellow 2002-115100 (4 x 25) 10-way 2002-410100 (4 x 25) Marking strip, plain, 11 mm wide Push-in type jumper bars, light gray, insulated, IN 25 A 50 m roll white 2009-110 1 1 - 3 2002-433200 (8 x 25) WMB Multi marking system, 1 - 4 2002-434200 (8 x 25) 10 strips with 10 markers per card, 1 - 5 2002-435100 (4 x 25) stretchable 5 - 5.2 mm : : plain 793-5501 5 1 - 10 2002-440100 (4 x 25) ® Modular TOPJOB S connector**, WMB Inline, plain, for jumper contact slot stretchable 5 - 5.2mm, 1 pole 2002-511100 (4 x 25) 1,500 WMB markers, 5mm, on roll white 2009-115 1 Spacer, modular 2002-549100 (4 x 25) Test plug adapter, for test plug 4 mm Ø 2009-174 100 (4 x 25) gray Testing tap, for max. 2.5 mm2 gray 2009-182 100 (4 x 25) 28 <_12 _> / <____ 39‑mm 1.54 in _____> / <____ 39‑mm 1.54 in _____> 2002 Series terminal blocks can accomodate: 0.25mm2 (22 AWG) - 4mm2 (12 AWG) solid or stranded wire; or direct insertion of: 0.75mm2 (18 AWG) - 4mm2 (12 AWG) solid or 0.75mm2 (18 AWG) - 2.5mm2 (14 AWG) stranded wire with ferrule (12mm barrel length) 3- and 4-conductor terminal blocks The TOPJOB®S rail-mounted terminal blocks have a conductor entry angle of 35 degrees allowing for a very small bend radius and an extremely short wiring distance to the cable duct. For applications in switchgear and control cabinets using the LSC wiring system from Lütze, for example, the new terminal blocks offer a space and cost saving solution. This way, conductors can be placed very close to the terminal blocks and their height can be kept relatively low. Product features ® • CAGE CLAMP S connection for all types of conductors, with the additional benefit that stripped solid wires and fine-stranded ferruled wires can be simply pushed in ibration-proof, fast, maintenance-free con•V nection • 3-conductor through and ground (earth) conductor terminal blocks equipped with dual jumper slot • 4-conductor terminal blocks allow for the multiplication of potentials without using any jumpers and any additional terminal blocks • 3- and 4-conductor terminal blocks have the same dimensions Push-In Type Wire Jumpers Test Plug Adapter and Testing Tap Test plug adapter and testing tap for testing rail-mounted terminal blocks of Series 2001/2002/2004/2006/2010/2016 Motor Configuration Jumpers Push-in type wire jumper Nominal voltage: 800 V/8 kV/3 Nominal current: 16 A Rated cross section: 1.5 mm2 Wire lengths: 60/110/250 mm Motor Configuration Jumpers Nominal voltage: 800 V/8 kV/3 Nominal current: In = In terminal block of relevant series Push-in type jumper bar 2002-405/011-000 2002-406/020-000 Item Pack. unit No.pcs Test plug adapter, for test plugs 4 mm/0.157 in Ø, for testing rail-mounted terminal blocks of Series 2001/2002/2004/2006/2010/2016 2009-174 100 (4 x 25) Testing tap, for connecting individual test wires of AWG 28 to 14 (0.08 mm2 – 2.5 mm2) without tools 2009-182 100 (4 x 25) Testing TOPJOB®S rail-mounted terminal blocks using a test plug adapter or testing tap ItemPack.-unit No.pcs ItemPack.-unit No.pcs Push-in type wire jumpers, insulated, conductor cross section 1.5 mm2, suitable for rail-mounted terminal blocks of Series 2001, 2002 and 2022 Wye configuration jumpers, light gray, insulated Suitable for Series: 2000 2000-405/011-000 2001 2001-405/011-000 2002 2002-405/011-000 2004 2004-405/011-000 2006 2006-405/011-000 2010 2010-405/011-000 2016 2016-405/011-000 Wire length 60 mm2009-412 100 110 mm2009-414 100 250 mm2009-416 100 Push down the wire jumper until fully inserted. Lift the jumper with a screwdriver for rewiring. Push-in type wire jumpers, insulated cross section, 0.75 mm2, suitable for rail-mounted terminal blocks of series 2000 and 2020. Wire length 60 mm 110 mm 250 mm 2009-402 2009-404 2009-406 This jumper has been specially developed to create awye configuration and is used on motor terminal boardsequipped with TOPJOB®S rail-mounted terminal blocks Delta jumpers, light gray, insulated Suitable for Series: 2000 2000-406/020-000 2001 2001-406/020-000 2002 2002-406/020-000 2004 2004-406/020-000 100 100 100 Lockout cap, for conductor entry hole and operating slot gray gray 2002-191 2006-191 25 25 This jumper has been specially developed to create a "delta" configuration and is used on motor terminal boards equipped with TOPJOB®S rail-mounted terminal blocks Lockout cap for covering unused clamping units of the 2002 or 2006 Series terminal blocks. 29 ? Adjacent Jumpers for Continuous Commoning, Vertical Jumpers, Adjacent Colored Push-In Jumper Bars Adjacent jumper for continuous commoning Slim style jumper bar Push-in type jumper bars Vertical jumpers ItemPack.-unit No.pcs Adjacent jumper for continuous commoning, insulated, IN 25 A 2-way 2002-400 100 (4x25) Double-deck vertical jumper, insulated, IN 24 A light gray 2002-492 50 (2 x 25) Triple-deck vertical jumper, insulated, IN 24 A light gray 2002-493 50 (2 x 25) Double-deck vertical jumper, insulated, IN 13.5 A light gray 2000-492 50 (2 x 25) Vertical jumper 30 ItemPack.-unit No.pcs Push-in slim style jumper bar, insulated, IN 25 A 2-way 2002-472 3-way 2002-473 4-way 2002-474 5-way 2002-475 : : 12-way 2002-482 Slim style jumper 100 (4x25) 100 (4x25) 100 (4x25) 50 (2x25) 50 (2x25) ItemPack.-unit No.pcs Push-in type jumper bar, insulated, IN 25 A blue 2-way 2002-402/000-006 3-way 2002-403/000-006 4-way 2002-404/000-006 5-way 2002-405/000-006 6-way 2002-406/000-006 7-way 2002-407/000-006 8-way 2002-408/000-006 9-way 2002-409/000-006 10-way 2002-410/000-006 200 (8 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) Push-in type jumper bar, insulated, IN 25 A red 2-way 2002-402/000-005 3-way 2002-403/000-005 4-way 2002-404/000-005 5-way 2002-405/000-005 6-way 2002-406/000-005 7-way 2002-407/000-005 8-way 2002-408/000-005 9-way 2002-409/000-005 10-way 2002-410/000-005 200 (8 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) Colored push-in type jumper bars are used with sensor terminal blocks ? Connector Strips with CAGE CLAMP ®S Connection 2001 Series 2002 Series 2004 Series 0.25 – 1.5 (2.5) mm2 AWG 22 – 14 500 V/6 kV/3 300 V, 15 A U 18 A 300 V, 15 A 2 Terminal block width 4.2 mm / 0.165 in L 9 – 11 mm / 0.39 in 0.25 – 2.5 (4) mm2 AWG 22 – 12 500 V/6 kV/3 300 V, 20 A U 24 A 300 V, 20 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in 0.5 – 4 (6) mm2 AWG 20 – 10 500 V/6 kV/3 300 V, 30 A U 32 A 300 V, 30 A 2 Terminal block width 6.2 mm / 0.244 in L 11 – 13 mm / 0.47 in Item No. Item No. Item No. Pack.-unit pcs Pack.-unit pcs Pack.-unit pcs Modular TOPJOB®S connector strips with CAGE CLAMP ®S connection, modular, gray, 2-pole 2001-552 3-pole 2001-553 4-pole 2001-554 5-pole 2001-555 6-pole 2001-556 7-pole 2001-557 8-pole 2001-558 9-pole 2001-559 10-pole 2001-560 Modular TOPJOB®S connector strips with CAGE CLAMP ®S connection, modular, gray, 2-pole 2002-552 3-pole 2002-553 4-pole 2002-554 5-pole 2002-555 6-pole 2002-556 7-pole 2002-557 8-pole 2002-558 9-pole 2002-559 10-pole 2002-560 Modular TOPJOB®S connector strips with CAGE CLAMP ®S connection, modular, gray, 2-pole 2004-552 2004-553 3-pole 2004-554 4-pole 2004-555 5-pole Item-specific accessories Item-specific accessories Item-specific accessories WMB Multi marking card, 10 strips with 10 markers each, white with black printing, 4 – 4.2 mm/0.157 - 0.165 in wide 5 cards 793-4 . . . 794-4 . . . 5 cards see pages 90-92 WMB Multi marking card, 10 strips with 10 markers each, white with black printing, 5 – 5.2 mm/0.197 - 0.205 in wide 5 cards 793-5 . . . 794-5 . . . 5 cards see pages 90-92 The modular connectors provide an additional connection option for conductors of the same cross section range as the terminal blocks being used. WMB Multi marking card, 10 strips with 10 markers each, white with black printing, 5 – 5.2 mm/0.197 - 0.205 in wide 5 cards 793-5 . . . 794-5 . . . 5 cards see pages 90-92 The connector has a test socket for 2 mm/0.079 in or 2.3 mm/0.091 in test plugs. Accessories for TOPJOB®S connectors Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Test plug, with cable 500‑mm /1’7.7’’ 2.3 mm/0.091 in Ø yellow210-137 50 (5 x 10) Test plug, with cable 500‑mm /1’7.7’’ 2 mm/0.079 in Ø red210-136 50 (5 x 10) Strain relief plate, gray snappable onto connector strips 6 mm /0.236 in wide 12.5 mm /0.492 in wide 25 mm /0.984 in wide 35 mm /1.378 in wide 734-327 734-328 734-329 734-326 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) Marker strips, plain, on roll 11 mm /0.039 in wide 50 m 2009-110 1 WMB Inline, plain, stretchable 5 - 5.2mm, 1,500 WMB markers, 5mm, on roll white 2009-115 1 31 ? Modular Connectors with CAGE CLAMP ®S Connection 2001 Series 2002 Series 2004 Series 0.25 – 1.5 (2.5) mm2 AWG 22 – 14 500 V/6 kV/3 300 V, 15 A U 18 A 300 V, 15 A 2 Terminal block width 4.2 mm / 0.165 in L 9 – 11 mm / 0.39 in Item No. Pack.-unit pcs 0.5 – 4 (6) mm2 AWG 20 – 10 500 V/6 kV/3 300 V, 30 A U 32 A 300 V, 30 A 2 Terminal block width 6.2 mm / 0.244 in L 11 – 13 mm / 0.47 in Item No. Item No. Pack.-unit pcs Pack.-unit pcs Modular TOPJOB S connectors with CAGE CLAMP ®S connection, modular, gray, 1 pole 2001-511 100 (4 x 25) Modular TOPJOB S connectors with CAGE CLAMP ®S connection, modular, gray, 1 pole 2002-511 100 (4 x 25) Modular TOPJOB S connectors with CAGE CLAMP ®S connection, modular, gray, 1 pole 2004-511 100 (4 x 25) Spacer, for bridging over commoned terminal blocks, for example, modular, gray 2001-549 100 (4 x 25) Spacer, for bridging over commoned terminal blocks, for example, modular, gray 2002-549 100 (4 x 25) Spacer, for bridging over commoned terminal blocks, for example, modular, gray 2004-549 100 (4 x 25) ® ® ® Item-specific accessories Item-specific accessories Item-specific accessories End plate, 1.5 mm/0.059 in thick gray 2002-541 100 (4 x 25) End plate, 1.5 mm/0.059 in thick gray 2002-541 100 (4 x 25) End plate, 1.5 mm/0.059 in thick gray 2004-541 100 (4 x 25) WMB Multi marking card, 10 strips with 10 markers each, white with black printing, 4 – 4.2 mm/0.157 - 0.165 in wide 5 cards 793-4 . . . 794-4 . . . 5 cards see pages 90-92 WMB Multi marking card, 10 strips with 10 markers each, white with black printing, 5 – 5.2 mm/0.197 - 0.205 in wide 5 cards 793-5 . . . 794-5 . . . 5 cards see pages 90-92 WMB Multi marking card, 10 strips with 10 markers each, white with black printing, 5 – 5.2 mm/0.197 - 0.205 in wide 5 cards 793-5 . . . 794-5 . . . 5 cards see pages 90-92 Snapping together of connectors and spacers to assemble a multi-pole connector 32 2 AWG 22 – 12 0.25 – 2.5 (4) mm 500 V/6 kV/3 300 V, 20 A U 24 A 300 V, 20 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in Wire connection: Screwdriver actuation for connection of all conductor types, i.e. stripped stranded conductors, or push-in connection of solid or ferruled stranded conductors. Snapping on a strain relief plate Accessories for TOPJOB®S connectors Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Test plug, with cable 500‑mm /1’7.7’’ 2.3 mm/0.091 in Ø yellow210-137 50 (5 x 10) Test plug, with cable 500‑mm /1’7.7’’ 2 mm/0.079 in Ø red210-136 50 (5 x 10) Strain relief plate, gray snappable onto connector strips 6 mm /0.236 in wide 12.5 mm /0.492 in wide 25 mm /0.984 in wide 35 mm /1.378 in wide 734-327 734-328 734-329 734-326 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) Marker strips, withe, plain, on roll 11 mm /0.039 in wide 50 m 2009-110 1 WMB Inline, plain, stretchable 5 - 5.2mm, 1,500 WMB markers, 5mm, on roll white 2009-115 1 ? Modular Connectors with CAGE CLAMP®S Connection, 2006 Series 2010 Series 2016 Series 0.5 – 4 (6) mm2 AWG 20 – 10 500 V/6 kV/3 IN 32 A Terminal block width 7.5 mm / 0.295 in L 11 – 13 mm / 0.47 in 2 AWG 20 – 10 0.5 – 4 (6) mm 500 V/6 kV/3 IN 32 A Terminal block width 10 mm / 0.394 in L 11 – 13 mm / 0.47 in 2 AWG 20 – 10 0.5 – 4 (6) mm 500 V/6 kV/3 IN 32 A Terminal block width 12 mm / 0.472 in L 11 – 13 mm / 0.47 in ItemPack.-unit No.pcs ItemPack.-unit No.pcs ® TOPJOB S connector, for jumper contact slot, modular, gray 2006-511 50 (2x25) 1-pole ItemPack.-unit No.pcs ® TOPJOB S connector, for jumper contact slot, modular, gray 2010-511 50 (2x25) 1-pole TOPJOB®S connector, for jumper contact slot, modular, gray 2016-511 1-pole Spacer module, can be snapped together, e.g., for bridging commoned terminal blocks 2006-549 50 (2x25) gray Spacer module, can be snapped together, e.g., for bridging commoned terminal blocks 2010-549 50 (2x25) gray Spacer module, can be snapped together, e.g., for bridging commoned terminal blocks 2016-549 50 (2x25) gray Accessories Connector Strips End plate, for modular TOPJOB®S connectors, 1.5 mm thick gray 2004-541 100 (4 x 25) Test plug, 500 mm /17.7 in cable 2.3 mm Ø yellow 210-137 50 Test plug, 500 mm /17.7 in cable 2 mm Ø red 210-136 50 50 (2x25) Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Strain relief plate, gray 3.5 mm wide 6 mm wide 12.5 mm wide 25 mm wide 734-326 734-327 734-328 734-329 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) Marker strips, plain, 11 mm wide 50 m roll white 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 5 33 0.25 – 2.5 (4) mm2 AWG 22 – 12 300 V/6 kV/3 IN 18 A Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in Simply push-in to conductor entry and pull out to remove 34 ? Double Deck Terminal Blocks 1 (1.5) mm2 /AWG 16 2000 Series <_____ 69.7‑mm /2.74‑in _____> <_____ 69.7‑mm /2.74‑in _____> Pack.-unit pcs 50 50 50 50 Through/through terminal block, without marking carrier, housing color blue N/N 2000-2204 50 Pack.-unit pcs 50 50 50 <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> Through/through terminal block, without marking carrier, housing color gray 2000-2201 L /L N/L 2000-2202 L/N 2000-2203 Item No. Through/through terminal block, with marking carrier, housing color blue N/N 2000-2234 <_____ 69.7‑mm /2.74‑in _____> Item Pack.-unit No. pcs 4-conductor through terminal block, with marking carrier, internal commoning, conductor entry position colored in violet, housing color gray L 2000-2238 50 <_____ 69.7‑mm /2.74‑in _____> <_____ 69.7‑mm /2.74‑in _____> Item No. Ground conductor/through terminal block, with marking carrier, housing color gray PE/N 2000-2247 PE/L 2000-2257 Pack.-unit pcs 50 50 Ground conductor/through terminal block, without marking carrier, housing color gray PE/N 2000-2217 PE/L 2000-2227 50 50 <_____ 69.7‑mm /2.74‑in _____> Item Pack.-unit No. pcs 4-conductor through terminal block, with marking carrier, internal commoning, conductor entry position colored in violet, housing color blue N 2000-2239 50 4-conductor through terminal block, 4-conductor through terminal block, without marking carrier, internal commoning, conductor entry without marking carrier, internal commoning, conductor entry position colored in violet, housing color gray position colored in violet, housing color blue L 2000-2208 50 N 2000-2209 50 Accessories Terminal block width 3.5 mm / 0.138 in L 9 – 11 mm / 0.39 in <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> Item No. Through/through terminal block, with marking carrier, housing color gray 2000-2231 L /L N/L 2000-2232 L/N 2000-2233 AWG 24 – 16 <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> Terminal block width 3.5 mm / 0.138 in L 9 – 11 mm / 0.39 in 4-Zulassungen in Vorbereitung 0.14 – 1 (1.5) mm2 500 V/6 kV/3 IN 13.5 A <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> Terminal block width 3.5 mm / 0.138 in L 9 – 11 mm / 0.39 in 4-Zulassungen in Vorbereitung AWG 24 – 16 600 V, 10 A U 600 V, 10 A 2 <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> 0.14 – 1 (1.5) mm2 500 V/6 kV/3 IN 13.5 A AWG 24 – 16 600 V, 10 A U 600 V, 10 A 2 <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> 0.14 – 1 (1.5) mm2 500 V/6 kV/3 IN 13.5 A Item No. 4-conductor ground terminal block, with marking carrier, internal commoning Housing color green-yellow PE 2000-2237 4-conductor ground terminal block, without marking carrier, internal commoning Housing color green-yellow PE 2000-2207 Pack.-unit pcs 50 50 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) End and intermediate plate, 0.7 mm thick orange 2000-2292 100 (4 x 25) gray 2000-2291 100 (4 x 25) Double-deck marker carrier, pivotable, gray 2000-121 Push-in type jumper bars, light gray, insulated, IN 14 A 2-way 2000-402 200 (8 x 25) 3-way 2000-403 200 (8 x 25) 4-way 2000-404 200 (8 x 25) 5-way 2000-405 100 (4 x 25) : : 10-way 2000-410 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 14 A 1 - 3 2000-433 200 (8 x 25) 1 - 4 2000-434 200 (8 x 25) 1 - 5 2000-435 100 (4 x 25) : : 1 - 10 2000-440 100 (4 x 25) 50 (4 x 25) Protective warning marker, with high voltage symbol, for 5 terminal blocks yellow 2000-115 100 (4 x 25) Marking strip, white, plain 11 mm wide 50 m roll 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, for 3.5 mm terminal block width plain 793-3501 5 35 ? Double Deck Terminal Blocks 1 (1.5) mm2 with End Plate/AWG 16 2000 Series <_____ 69.7‑mm /2.74‑in _____> Item Pack.-unit No. pcs Through/through terminal block, with end plate with marking carrier, housing color gray 2000-2231/099-000 50 L /L N/L 2000-2232/099-000 50 L/N 2000-2233/099-000 50 Through/through terminal block, with end plate with outmarking carrier, housing color blue N/N 2000-2204/099-000 50 <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> Through/through terminal block, with end plate without marking carrier, housing color gray 2000-2201/099-000 50 L /L N/L 2000-2202/099-000 50 L/N 2000-2203/099-000 50 Item Pack.-unit No. pcs Through/through terminal block, with end plate with marking carrier, housing color blue N/N 2000-2234/099-000 50 <_____ 69.7‑mm /2.74‑in _____> Item Pack.-unit No. pcs 4-conductor through terminal block, with end plate with marking carrier, internal commoning, conductor entry position colored in violet, housing color gray L 2000-2238/099-000 50 <_____ 69.7‑mm /2.74‑in _____> Item Pack.-unit No. pcs 4-conductor through terminal block, with end plate with marking carrier, internal commoning, conductor entry position colored in violet, housing color blue N 2000-2239/099-000 50 36 Item Pack.-unit No. pcs Ground conductor/through terminal block, with end plate with marking carrier, housing color gray PE/N 2000-2247/099-000 50 PE/L 2000-2257/099-000 50 Ground conductor/through terminal block, with end plate without marking carrier, housing color gray PE/N 2000-2217/099-000 50 PE/L 2000-2227/099-000 50 Item Pack.-unit No. pcs 4-conductor ground terminal block, with end plate with marking carrier, internal commoning Housing color green-yellow PE 2000-2237/099-000 50 4-conductor ground terminal block, with end plate without marking carrier, internal commoning Housing color green-yellow PE 2000-2207/099-000 50 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Double-deck marker carrier, pivotable, gray 2000-121 Push-in type jumper bars, light gray, insulated, IN 18 A 2-way 2001-402 200 (8 x 25) 3-way 2001-403 200 (8 x 25) 4-way 2001-404 200 (8 x 25) 5-way 2001-405 100 (4 x 25) : : 10-way 2001-410 100 (4 x 25) <_____ 69.7‑mm /2.74‑in _____> <_____ 69.7‑mm /2.74‑in _____> 4-conductor through terminal block, with end plate 4-conductor through terminal block, with end plate without marking carrier, internal commoning, conductor entry without marking carrier, internal commoning, conductor entry position colored in violet, housing color gray position colored in violet, housing color blue L 2000-2208/099-000 50 N 2000-2209/099-000 50 Accessories Terminal block width 4.2 mm / 0.165 in L 9 – 11 mm / 0.39 in <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> <_____ 69.7‑mm /2.74‑in _____> AWG 24 – 16 <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> Terminal block width 4.2 mm / 0.165 in L 9 – 11 mm / 0.39 in 4-Zulassungen in Vorbereitung 0.14 – 1 (1.5) mm2 800 V/8 kV/3 IN 13.5 A (18 A) <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> Terminal block width 4.2 mm / 0.165 in L 9 – 11 mm / 0.39 in 4-Zulassungen in Vorbereitung AWG 24 – 16 600 V, 10 A U 600 V, 10 A 2 <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> 0.14 – 1 (1.5) mm2 800 V/8 kV/3 IN 13.5 A (18 A) AWG 24 – 16 600 V, 10 A U 600 V, 10 A 2 <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> 0.14 – 1 (1.5) mm2 800 V/8 kV/3 IN 13.5 A (18 A) 50 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 18 A 1 - 3 2001-433 200 (8 x 25) 1 - 4 2001-434 200 (8 x 25) 1 - 5 2001-435 100 (4 x 25) : : 1 - 10 2001-440 100 (4 x 25) Protective warning marker, with high voltage symbol, for 5 terminal blocks yellow 2000-115 100 (4 x 25) Marking strip, white, plain 11 mm wide 50 m roll 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, for 4-4.2 mm terminal block width plain 793-4501 5 ? Double Deck Terminal Blocks 2.5 (4) mm2/AWG 12 2002 Series <_____ 70mm /2.76in _____> Pack.-unit pcs 50 50 50 50 Through/through terminal block, with outmarking carrier, housing color blue N/N 4 2002-2204 50 Pack.-unit pcs 50 50 50 <_ 52 mm /2.04‑in _> <___ 62 mm /2.44‑in ____> Through/through terminal block, without marking carrier, housing color gray 2002-2201 L /L 4 N/L 4 2002-2202 2002-2203 L/N 4 Item No. Through/through terminal block, with marking carrier, housing color blue N/N 4 2002-2234 <_____ 70mm /2.76in _____> Item Pack.-unit No. pcs 4-conductor through terminal block, with marking carrier, internal commoning, conductor entry position colored in violet, housing color gray L 4 2002-2238 50 <_____ 70mm /2.76in _____> <_ 52 mm /2.04‑in _> <___ 62 mm /2.44‑in ____> Item No. Ground conductor/through terminal block, with marking carrier, housing color gray PE/N 4 2002-2247 PE/L 4 2002-2257 Pack.-unit pcs 50 50 Ground conductor/through terminal block, without marking carrier, housing color gray PE/N 4 2002-2217 PE/L 4 2002-2227 50 50 <_____ 70mm /2.76in _____> Item Pack.-unit No. pcs 4-conductor through terminal block, with marking carrier, internal commoning, conductor entry position colored in violet, housing color blue N 4 2002-2239 50 4-conductor through terminal block, 4-conductor through terminal block, without marking carrier, internal commoning, conductor entry without marking carrier, internal commoning, conductor entry position colored in violet, housing color gray position colored in violet, housing color blue L 4 2002-2208 50 N 4 2002-2209 50 Accessories <_____ 70mm /2.76in _____> <_ 52 mm /2.04‑in _> <___ 62 mm /2.44‑in ____> Item No. Through/through terminal block, with marking carrier, housing color gray 2002-2231 L /L 4 N/L 4 2002-2232 2002-2233 L/N 4 0.25 – 2.5 (4) mm2 AWG 22 – 12 800 V/8 kV/3 300 V, 20 A U IN 24 A 600 V, 20 A 2 Terminal block width 5.2 / 0.205 in L 10 – 12 mm / 0.43 in <_ 52 mm /2.04‑in _> <___ 62 mm /2.44‑in ____> <_____ 70mm /2.76in _____> <_ 52 mm /2.04‑in _> <___ 62 mm /2.44‑in ____> 0.25 – 2.5 (4) mm2 AWG 22 – 12 800 V/8 kV/3 300 V, 20 A U IN 24 A 600 V, 20 A 2 Terminal block width 5.2 / 0.205 in L 10 – 12 mm / 0.43 in <_ 52 mm /2.04‑in _> <___ 62 mm /2.44‑in ____> 0.25 – 2.5 (4) mm2 AWG 22 – 12 800 V/8 kV/3 300 V, 20 A U IN 24 A 600 V, 20 A 2 Terminal block width 5.2 / 0.205 in L 10 – 12 mm / 0.43 in Item No. 4-conductor ground terminal block, with marking carrier, internal commoning Housing color green-yellow PE 4 2002-2237 4-conductor ground terminal block, without marking carrier, internal commoning Housing color green-yellow PE 4 2002-2207 Pack.-unit pcs 50 50 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) End and intermediate plate, 0.7 mm thick orange 2002-2292 100 (4 x 25) gray 2002-2291 100 (4 x 25) Double-deck marker carrier, pivotable, gray 2002-121 Push-in type jumper bars, light gray, insulated, IN 14 A 2-way 2002-402 200 (8 x 25) 3-way 2002-403 200 (8 x 25) 4-way 2002-404 200 (8 x 25) 5-way 2002-405 100 (4 x 25) : : 10-way 2002-410 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 14 A 1 - 3 2002-433 200 (8 x 25) 1 - 4 2002-434 200 (8 x 25) 1 - 5 2002-435 100 (4 x 25) : : 1 - 10 2002-440 100 (4 x 25) 50 (4 x 25) Protective warning marker, with high voltage symbol, for 5 terminal blocks yellow 2002-115 100 (4 x 25) Marking strip, white, plain 11 mm wide 50 m roll 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, for 4-4.2 mm terminal block width plain 793-5501 5 37 ? Double Deck Terminal Blocks 2.5 (4) mm2 with End Plate/AWG 12 2002 Series Item Pack.-unit No. pcs Through/through terminal block, with end plate with marking carrier, housing color gray 2002-2231/099-000 50 L /L N/L 2002-2232/099-000 50 L/N 2002-2233/099-000 50 Through/through terminal block, with end plate without marking carrier, housing color blue N/N 2002-2204/099-000 50 <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> Through/through terminal block, with end plate without marking carrier, housing color gray 2002-2201/099-000 50 L /L N/L 2002-2202/099-000 50 L/N 2002-2203/099-000 50 Item Pack.-unit No. pcs Through/through terminal block, with end plate with marking carrier, housing color blue N/N 2002-2234/099-000 50 <_____ 69.7‑mm /2.74‑in _____> Item Pack.-unit No. pcs 4-conductor through terminal block, with end plate with marking carrier, internal commoning, conductor entry position colored in violet, housing color gray L 2002-2238/099-000 50 <_____ 69.7‑mm /2.74‑in _____> Item Pack.-unit No. pcs 4-conductor through terminal block, with end plate with marking carrier, internal commoning, conductor entry position colored in violet, housing color blue N 2002-2239/099-000 50 38 <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> Ground conductor/through terminal block, with end plate without marking carrier, housing color gray PE/N 2002-2217/099-000 50 PE/L 2002-2227/099-000 50 Item Pack.-unit No. pcs 4-conductor ground terminal block, with end plate with marking carrier, internal commoning Housing color green-yellow PE 2002-2237/099-000 50 4-conductor ground terminal block, with end plate without marking carrier, internal commoning Housing color green-yellow PE 2002-2207/099-000 50 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Double-deck marker carrier, pivotable, gray 2002-121 Push-in type jumper bars, light gray, insulated, IN 32 A 2-way 2004-402 200 (8 x 25) 3-way 2004-403 200 (8 x 25) 4-way 2004-404 200 (8 x 25) 5-way 2004-405 100 (4 x 25) : : 10-way 2004-410 100 (4 x 25) Item Pack.-unit No. pcs Ground conductor/through terminal block, with end plate with marking carrier, housing color gray PE/N 2002-2247/099-000 50 PE/L 2002-2257/099-000 50 <_____ 69.7‑mm /2.74‑in _____> 4-conductor through terminal block, with end plate 4-conductor through terminal block, with end plate without marking carrier, internal commoning, conductor entry without marking carrier, internal commoning, conductor entry position colored in violet, housing color gray position colored in violet, housing color blue L 2002-2208/099-000 50 N 2002-2209/099-000 50 Accessories <_____ 69.7‑mm /2.74‑in _____> <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> <_____ 69.7‑mm /2.74‑in _____> 0.25 – 2.5 (4) mm2 AWG 22 – 12 800 V/8 kV/3 IN 24 A Terminal block width 6.2 / 0.244 in L 10 – 12 mm / 0.43 in <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> <_____ 69.7‑mm /2.74‑in _____> <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> 0.25 – 2.5 (4) mm2 AWG 22 – 12 800 V/8 kV/3 600 V, 20 A U IN 24 A 600 V, 20 A 2 Terminal block width 6.2 / 0.244 in L 10 – 12 mm / 0.43 in <_ 51.7 mm /2.04‑in _> <___ 61.8 mm /2.43‑in ____> 0.25 – 2.5 (4) mm2 AWG 22 – 12 800 V/8 kV/3 600 V, 20 A U IN 24 A 600 V, 20 A 2 Terminal block width 6.2 / 0.244 in L 10 – 12 mm / 0.43 in 50 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 32 A 1 - 3 2004-433 200 (8 x 25) 1 - 4 2004-434 200 (8 x 25) 1 - 5 2004-435 100 (4 x 25) : : 1 - 10 2004-440 100 (4 x 25) Protective warning marker, with high voltage symbol, for 5 terminal blocks yellow 2000-115 100 (4 x 25) Marking strip, white, plain 11 mm wide 50 m roll 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, for 5-5.2 mm terminal block width plain 793-5501 5 ? 4-Conductor, Double Deck Terminal Blocks 2.5 (4) mm2/AWG 12 2002 Series <_____ 105.5mm /4.15in _____> 50 50 50 Item No. Through/through terminal block, with marking carrier, housing color blue N/N 2002-2434 Pack.-unit pcs 50 Through/through terminal block, without marking carrier, housing color blue N/N 2002-2404 50 50 50 50 <_ 52.5 mm /2.07in _> <___ 63 mm /2.48in ____> Through/through terminal block, without marking carrier, housing color gray 2002-2401 L /L N/L 2002-2402 L/N 2002-2403 Pack.-unit pcs <_____ 105.5mm /4.15in _____> Item Pack.-unit No. pcs 8-conductor through terminal block, with marking carrier, internal commoning, conductor entry position colored in violet, housing color gray L 2002-2438 50 <_____ 105.5mm /4.15in _____> <_ 52.5 mm /2.07in _> <___ 63 mm /2.48in ____> Pack.-unit pcs 50 50 Ground conductor/through terminal block, without marking carrier, housing color gray PE/N 2002-2417 PE/L 2002-2427 50 50 <_____ 105.5mm /4.15in _____> Item Pack.-unit No. pcs 8-conductor through terminal block, with marking carrier, internal commoning, conductor entry position colored in violet, housing color blue N 2002-2439 50 8-conductor through terminal block, 8-conductor through terminal block, without marking carrier, internal commoning, conductor entry without marking carrier, internal commoning, conductor entry position colored in violet, housing color gray position colored in violet, housing color blue L 2002-2408 50 N 2002-2409 50 Accessories Item No. Ground conductor/through terminal block, with marking carrier, housing color gray PE/N 2002-2447 PE/L 2002-2457 <_ 52.5 mm /2.07in _> <___ 63 mm /2.48in ____> Item No. Through/through terminal block, with marking carrier, housing color gray 2002-2431 L /L N/L 2002-2432 L/N 2002-2433 <_____ 105.5mm /4.15in _____> <_ 52.5 mm /2.07in _> <___ 63 mm /2.48in ____> <_____ 105.5mm /4.15in _____> 0.25 – 2.5 (4) mm2 AWG 22 – 12 800 V/8 kV/3 600 V, 20 A U IN 24 A (28 A) 600 V, 20 A 2 Terminal block width 5.2 / 0.205 in L 10 – 12 mm / 0.43 in <_ 52.5 mm /2.07in _> <___ 63 mm /2.48in ____> 0.25 – 2.5 (4) mm2 AWG 22 – 12 800 V/8 kV/3 600 V, 20 A U IN 24 A (28 A) 600 V, 20 A 2 Terminal block width 5.2 / 0.205 in L 10 – 12 mm / 0.43 in <_ 52.5 mm /2.07in _> <___ 63 mm /2.48in ____> 0.25 – 2.5 (4) mm2 AWG 22 – 12 800 V/8 kV/3 600 V, 20 A U IN 24 A (28 A) 600 V, 20 A 2 Terminal block width 5.2 / 0.205 in L 10 – 12 mm / 0.43 in Item No. 8-conductor ground terminal block, with marking carrier, internal commoning Housing color green-yellow PE 2002-2437 8-conductor ground terminal block, without marking carrier, internal commoning Housing color green-yellow PE 2002-2407 Pack.-unit pcs 50 50 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) End and intermediate plate, 0.7 mm thick orange 2002-2492 100 (4 x 25) gray 2002-2491 100 (4 x 25) Double-deck marker carrier, pivotable, gray 2002-121 Push-in type jumper bars, light gray, insulated, IN 14 A 2-way 2002-402 200 (8 x 25) 3-way 2002-403 200 (8 x 25) 4-way 2002-404 200 (8 x 25) 5-way 2002-405 100 (4 x 25) : : 10-way 2002-410 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 14 A 1 - 3 2002-433 200 (8 x 25) 1 - 4 2002-434 200 (8 x 25) 1 - 5 2002-435 100 (4 x 25) : : 1 - 10 2002-440 100 (4 x 25) 50 (4 x 25) Protective warning marker, with high voltage symbol, for 5 terminal blocks yellow 2002-115 100 (4 x 25) Marking strip, white, plain 11 mm wide 50 m roll 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, for 5-5.2 mm terminal block width plain 793-5501 5 39 ? Triple Deck Terminal Blocks 2.5 (4) mm2/AWG 12 2002 Series 50 50 <_ 69.5 mm /2.74‑in _> <___ 81.5 mm /3.21in ____> Through/through terminal block, without marking carrier, housing color gray 2002-3201 L /L /L 4 L/L/N 4 2002-3203 <_____ 93.5mm /3.68in _____> Item Pack.-unit No. pcs 6-conductor through terminal block, with marking carrier, internal commoning, conductor entry position colored in violet, housing color gray L 4 2002-3238 50 Item Pack.-unit No. pcs Through/through/through terminal block, with marking carrier, housing color blue N/N/N 4 2002-3234 50 Through/through terminal block, without marking carrier, housing color blue N/N/N 4 2002-3204 50 40 Ground conductor/through terminal block, without marking carrier, housing color gray PE/N/L 4 2002-3217 PE/L/L 4 2002-3227 50 50 <_____ 93.5mm /3.68in _____> <_____ 93.5mm /3.68in _____> Item Pack.-unit No. pcs 6-conductor through terminal block, with marking carrier, internal commoning, conductor entry position colored in violet, housing color blue N 4 2002-3239 50 6-conductor through terminal block, 6-conductor through terminal block, without marking carrier, internal commoning, conductor entry without marking carrier, internal commoning, conductor entry position colored in violet, housing color gray position colored in violet, housing color blue L 4 2002-3208 50 N 4 2002-3209 50 Accessories Item Pack.-unit No. pcs Ground conductor/through/through terminal block, with marking carrier, housing color gray PE/N/L 4 2002-3247 50 PE/L/L 4 2002-3257 50 <_ 69.5 mm /2.74‑in _> <___ 81.5 mm /3.21in ____> Item Pack.-unit No. pcs Through/through/through terminal block, with marking carrier, housing color gray 2002-3231 50 L /L /L 4 L/L/N 4 2002-3233 50 <_ 69.5 mm /2.74‑in _> <___ 81.5 mm /3.21in ____> <_____ 93.5mm /3.68in _____> <_____ 93.5mm /3.68in _____> <_ 69.5 mm /2.74‑in _> <___ 81.5 mm /3.21in ____> <_____ 93.5mm /3.68in _____> 0.25 – 2.5 (4) mm2 AWG 22 – 12 500 V/6 kV/3 IN 24 A (28 A) Terminal block width 5.2 / 0.205 in L 10 – 12 mm / 0.43 in <_ 69.5 mm /2.74‑in _> <___ 81.5 mm /3.21in ____> 0.25 – 2.5 (4) mm2 AWG 22 – 12 500 V/6 kV/3 300 V, 20 A U 600 V, 20 A 2 IN 24 A (28 A) Terminal block width 5.2 / 0.205 in L 10 – 12 mm / 0.43 in <_ 69.5 mm /2.74‑in _> <___ 81.5 mm /3.21in ____> 0.25 – 2.5 (4) mm2 AWG 22 – 12 500 V/6 kV/3 300 V, 20 A U IN 24 A (28 A) 600 V, 20 A 2 Terminal block width 5.2 / 0.205 in L 10 – 12 mm / 0.43 in Item No. 6-conductor ground terminal block, with marking carrier, internal commoning Housing color green-yellow PE 4 2002-3237 6-conductor ground terminal block, without marking carrier, internal commoning Housing color green-yellow PE 4 2002-3207 Pack.-unit pcs 50 50 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) End and intermediate plate, 0.7 mm thick orange 2002-3292 100 (4 x 25) gray 2002-3291 100 (4 x 25) Triple-deck marker carrier, pivotable, gray 2002-131 Push-in type jumper bars, light gray, insulated, IN 14 A 2-way 2002-402 200 (8 x 25) 3-way 2002-403 200 (8 x 25) 4-way 2002-404 200 (8 x 25) 5-way 2002-405 100 (4 x 25) : : 10-way 2002-410 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 14 A 1 - 3 2002-433 200 (8 x 25) 1 - 4 2002-434 200 (8 x 25) 1 - 5 2002-435 100 (4 x 25) : : 1 - 10 2002-440 100 (4 x 25) 50 (4 x 25) Protective warning marker, with high voltage symbol, for 5 terminal blocks yellow 2002-115 100 (4 x 25) Marking strip, white, plain 11 mm wide 50 m roll 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, for 5-5.2 mm terminal block width plain 793-5501 5 ? Quadruple Deck, Rail-Mounted Terminal Blocks or Rail-Mounted Terminal Blocks for Wiring of Electric Motors, 2002 Series/AWG 12 mm2 0.25 — 2.5 (4) 800 V/8 kV/3 IN 24 A AWG 22 — 12 mm2 Terminal block width 5.2 mm / 0.205 in L 10 — 12 mm / 0.43 in <_____ 103,5 mm /4.08 in ____> Item no. mm2 AWG 22 — 12 Terminal block width 5.2 mm / 0.205 in L 10 — 12 mm / 0.43 in <____ 83,9 mm / 3.3 in____> 96,8 mm / 3.8 in <____ 83,9 mm / 3.3 in____> 96,8 mm / 3.8 in Terminal block width 5.2 mm / 0.205 in L 10 — 12 mm / 0.43 in 0.25 — 2.5 (4) 800 V/8 kV/3 IN 24 A AWG 22 — 12 <____ 83,9 mm / 3.3 in____> 96,8 mm / 3.8 in 0.25 — 2.5 (4) 800 V/8 kV/3 IN 24 A <_____ 103,5 mm /4.08 in ____> Pack. unit Item no. <_____ 103,5 mm /4.08 in ____> Pack. unit Item no. Pack. unit Quadruple-deck, rail-mounted terminal block or Rail-mounted terminal block for wiring of electric motors, without marker carrier, gray L1 - L2 - L3 - PE 2002-4127 25 Quadruple-deck, rail-mounted terminal block or Rail-mounted terminal block for wiring of electric motors, without marker carrier, gray L1 - L2 2002-4111 25 Quadruple-deck, rail-mounted terminal block or Rail-mounted terminal block for wiring of electric motors, without marker carrier, gray L1 - L2 - L3 2002-4101 25 Quadruple-deck, rail-mounted terminal block or Rail-mounted terminal block for wiring of electric motors, with marker carrier, gray L1 - L2 - L3 - PE 2002-4157 25 Quadruple-deck, rail-mounted terminal block or Rail-mounted terminal block for wiring of electric motors, with marker carrier, gray L1 - L2 2002-4141 25 Quadruple-deck, rail-mounted terminal block or Rail-mounted terminal block for wiring of electric motors, with marker carrier, gray L1 - L2 - L3 2002-4131 25 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Accessories End and intermediate plate, 1 mm thick orange 2002-4192100 (4 x 25) gray 2002-4191100 (4 x 25) Protective warning marker, with high voltage symbol, for 5 terminal blocks yellow 2002-115 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A 2- 2002-402 200 (8 x 25) 3- 2002-403 200 (8 x 25) 4- 2002-404 200 (8 x 25) 5- 2002-405 100 (4 x 25) : : 10- 2002-410 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A 1-3 2002-433 200 (8 x 25) 1-4 2002-434 200 (8 x 25) 1-5 2002-435 100 (4 x 25) :: 1-10 2002-440 100 (4 x 25) Lockout cap, Triple-deck marker carrier pivoting gray 2002-131 50 (2 x 25) For motor and sensor applications for conductor entry and operating slot orange 2002-192 25 gray 2002-191 25 blue 2002-194 25 Star point jumper, insulated, IN = IN terminal block, light gray 1-3-52002-405/011-000 100 (4 x 25) Delta jumper, insulated, IN = IN terminal block, light gray 1-3 3-4 5-6 2002-406/020-000 100 (4 x 25) Adjacent jumper for continuous commoning, insulated, IN 25 A light gray 2-way 2002-400 100 (4 x 25) Marking strip, white, plain 11 mm wide 50 m roll 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, for 5-5.2 mm terminal block width plain 793-5501 5 41 Movable knife disconnects clearly indicate the circuit state. 2- and 4-conductor disconnect terminal blocks The 5.2 mm wide 2- and 4-conductor disconnect terminal blocks, that can be used in both control and process measurement systems as well as transformer circuits, are an addition to the range of TOPJOB®S rail-mounted terminal blocks. Two lateral and one center marker receptacle for WMB markers or marking strips. Dual jumper slots, in the same position as the other 2002 Series terminal blocks. Commoning options in front of or behind the knife disconnect, depending on which is the power supply side. Double deck double disconnect terminal blocks Disconnect terminal blocks of different potentials are accommodated on two levels in a double deck disconnect terminal block. This results in a space saving arrangement without compromising the clarity of operation. The knife disconnects are located between the conductors and are therefore always in full view of the operator. Disconnect terminal block for test and measurement, with knife disconnect, mechanical interlock and extra jumper location. One disconnect and one through terminal block are accommodated on two levels in a terminal block that is only 5.2 mm wide. 42 Disconnect and ground conductor disconnect terminal blocks Through terminal blocks and disconnect terminal blocks up to 8 AWG (6 mm2) Fuse terminal blocks Fuse terminal for automotive fuse according to DIN 72581-3f Fuse disconnect terminal with pivoting fuse holder for 5 x 20 mm and ¼" x 1 ¼" fuses Double-deck fuse and disconnect terminal blocks Terminal blocks combining functions of fusing or disconnect on upper level and through or ground connections on lower level save valuable space on the DIN-rail Pivoting fuse holder to locked open position 43 ? Disconnect Terminal Blocks for Test and Measurement with Movable Knife Disconnect and Through Terminal Blocks, 2002 Series 0.25 – 2.5 (4) 400 V/6 kV/3 16 A mm2 0.25 – 2.5 (4) 400 V/6 kV/3 IN 16 A AWG 22 – 12 300 V, 15 A U 600 V, 10 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in <_________ 66.5 mm /2.61 in _________> mm2 AWG 22 – 12 300 V, 15 A U 600 V, 10 A 2 / <___ 33‑mm 1.29 in ___> Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in / <___ 33‑mm 1.29 in ___> / <___ 33‑mm 1.29 in ___> <___ 38‑mm /1. 49‑in ___> 0.25 – 2.5 (4) mm2 AWG 22 – 12 300 V, 15 A U 400 V/6 kV/3 16 A 600 V, 10 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in !1 <_________ 66.5 mm /2.61 in _________> <_________ 66.5 mm /2.61 in _________> 97 ItemPack.-unit No.pcs 2-conductor disconnect terminal block for test and measurement 2002-1671 gray blue 2002-1674 2002-1672 orange Carrier terminal block with disconnect plug in operating position. Application example showing a 2-conductor carrier terminal block 2002-1661 with disconnect plug Item-specific accessories End and intermediate plate, 1 mm /0.039 in thick orange 2002-1692100 (4 x 25) gray 2002-1691100 (4 x 25) ItemPack.-unit No.pcs 2-conductor disconnect terminal block for test and measurement with mechanical interlock, with test point, orange disconnect link 2002-1671/401-000 gray blue 2002-1674/401-000 2002-1672/401-000 orange End and intermediate plate, 1 mm /0.039 in thick orange 2002-1692100 (4 x 25) gray 2002-1691100 (4 x 25) ItemPack.-unit No.pcs 2-conductor through terminal blocks, profile as disconnect terminal block same gray 2002-1601 sizes: 0.25 mm¤ o 4 mm¤ is + f-stw; 2002-1604 1 Conductor blue Push-in conductor sizes: 0.75 mm¤ o 4 mm¤ isw 2002-1602 orange and 0.75 mm¤ o 2.5 mm¤ iinsulated ferrules, 12 mmw 2 400 V = rated voltage 6 kV = rated surge voltage 1 Conductor sizes: 0.25 mm¤ o Push-in conductor sizes: 0.75 and 0.75 mm¤ o 2.5 mm¤ iinsulated ferrules, 12 mmw 3 = pollution degree (see Section 14) 2 400 V = rated voltage 6 kV = rated surge voltage 3 = pollution degree (see Section 14) 3 Strip length, see packaging or instructions. 4 See application notes for: Colored push-in type jumper bars, page 139 Carrier terminaljumper, block with plug in operating Staggered pagedisconnect 141 3 position. Adjacent jumper for continuous commoning, Application example showing a 2-conductor carrier termi4 page 139 Endnaland intermediate plate, 1 mmplug /0.039 in thick block 2002-1661 with disconnect Push-in type wire jumper, page 140 orange 2002-1692 1 00 (4 x 25) ¥ TOPJOB S connector, page 134 plug module, page 136 TOPJOB¥S L-type test gray 2002-1691 100 (4 x 25) Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Accessories 200 strips Insulation stop, 5 pcs/strip light gray2002-171 0.25-0.5 mm2 dark gray2002-172 0.75-1 mm2 Protective warning marker, for 5 terminal blocks yellow 2002-115 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A 2-way 2002-402200 (8 x 25) 3-way 2002-403200 (8 x 25) 4-way 2002-404200 (8 x 25) 5-way 2002-405100 (4 x 25) : : 10-way 2002-410100 (4 x 25) Slim style jumper, light gray, insulated, IN 25 A 2-way 2002-472100 (4 x 25) 3-way 2002-473100 (4 x 25) 4-way 2002-474100 (4 x 25) terminal 2002-475 x 25) 5-way 2-conductor disconnect block50 for(2test and measurement, with disconnect and mechanical : knife : interlock 2002-482 50 (2 x 25) 12-way Open position Push-in type jumper bars, light gray, insulated, IN 25 A Test plug adapter, for test plug 4 mm/0.157 in Ø 2009-174 100 (4 x 25) 215-111 50 Strip length, see packaging o See application notes for: Colored push-in type jumper Staggered jumper, page 141 Adjacent jumper for continuo page 139 Push-in type wire jumper, pag TOPJOB¥S connector, page 1 TOPJOB¥S L-type test plug m 1 - 3 2002-433200 (8 x 25) 1 -adapter, 4 2002-434200 (8 x 25) Test plug 2002-435100 1 - 5 for test plug 4 mm (4 x 25) : gray : 2009-174 100 (4x25) Testfor plug adapter, max. 2.5 mm2 1 - 10 2002-440100 (4 x 25) Testing tap, for test plug 4 mm 100 (4 x 25) Testing tap, 2009-182 gray 2009-174 100 (4x25) for max. 2.5 mm¤ Two-way marking adapter, Modular TOPJOB®S connector**, gray 2009-182 100 (4x25) for jumper contact slot pivotable Testing tap, 2002-121 50 (4 x 25) 1 pole 2002-511100 (4 x 25) for max. 2.5 mm¤ Banana plug, gray 2009-182 100 (4x25) for socket 4 mm , 2002-549100 (4 x 25) Spacer, modular color mixed 1 ! 2-conductor disconnect terminal block for testblock and 2-conductor disconnect terminal measurement, with knife disconnect and mechanical for test and measurement, with knife interlock Open position disconnect and mechanical interlock (open position) Banana plug, for socket 4 mm , Double-deck Test plug, with cable 500‑mmmarker /1’7.7’’carrier, color mixed 2-conductor disconnect terminal 2-conductor disconnect terminal block for test and 2-conductor disconnect terminal block for testblock and pivoting 2 mm/0.079 in Ø measurement, with knife disconnect and mechanical 215-111 50 measurement, with knife disconnect and mechanical gray 2002-121 for test and measurement, with knife red210-136 50 (5 x 10) 50 (2x25) interlock interlock Double-deck marker carrier, 44 WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 Marking strip, plain, 11 mm wide, 50 m roll Top view 5 pivoting gray 2002-121 Closing of knife disconnect disconnect and mechanical 2-conductor disconnect terminal block interlock for test and with knife disconnect and mechanical 50 (2x25) measurement, (closing of knife disconnect) interlock Top view WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 Marking strip, plain, 5 2-conductor disconnect termin measurement, with knife disc interlock Closing of knife disconnect ? TOPJOB¥@ Disconnect TerminalBlocks Blocksfor with Mechanical Disconnect Terminal Testand andwithout Measurement withoutInterlock and with with Additional Jumper Position, 2002 Series Mechanical Interlock with Additional Jumper Position 2.5 (4) mm¤, 2002 Series 102 0.25 - 2.5 (4) mm¤ 12 AWG 22 - 12 0.25 – 2.5 (4) mm AWG 22 – 12 2 400 300 V, 15 A U 400V/6 V/6kV/3 kV/3 IN16 16A A 600 V, 10 A 2 Terminal in in Terminalblock blockwidth width5.2 5.2mm mm/ 0.205 / 0.205 L1010 – mm 12 mm / 0.43 - 12 / 0.43 in 3in L 32,9 mm/1.3 in 37,9 mm/1.49 in 40,8 mm/1.61 in 72,9 mm/2.87 in Item No. Ǔ Ǔ Ǔ 0.25 - 2.5 (4) mm¤ 1 0.25 – 2.5 (4)2mm2 400 400 V/6 V/6 kV/3 kV/3 IINN 16 16 AA Item No. 2-conductor disconnect terminal block for test and measurement, with test point, orange disconnect link, with additional jumper position gray 2002-1971 50 blue 2002-1974 50 orange 2002-1972 50 300 V, 15 A U 600 V, 10 A 2 Terminal block width 5.2 mm / 0.205 in Terminal block width 5.2 mm / 0.205 in - 12 mmmm / 0.43 in 3 L L 1010 – 12 / 0.43 in 40,8 mm/1.61 in 72,9 mm/2.87 in Pack. Unit AWG 22 - 12 AWG 22 – 12 32,9 mm/1.3 in 38,9 mm/1.53 in Terminal mm / 0.205 in in Terminalblock blockwidth width5.2 5.2 mm / 0.205 L10 10 12 mm / 0.43 - 12– mm / 0.43 in 3in L 0.25 - 2.5 (4) mm¤ 1 AWG 22 - 12 mm2 AWG 22 – 12 0.25 – 2.5 (4) 2 400 300 V, 15 A U 400V/6 V/6kV/3 kV/3 IN16 16AA 600 V, 10 A 2 32,9 mm/1.3 in 1 Ǔ Ǔ Ǔ 40,8 mm/1.61 in 72,9 mm/2.87 in Pack. Unit 2-conductor disconnect terminal block for test and measurement with mechanical interlock, with test point, orange disconnect link, with additional jumper position gray 2002-1971/401-000 50 orange 2002-1972/401-000 50 50 blue 2002-1974/401-000 blue 2002-1974/401-000 50 2002-1972/401-000 orange Item No. Pack. Unit 2-conductor through terminal block, with test point, with additional jumper position, same profile as 2-conductor disconnect terminal block Ǔ Ǔ Ǔ gray blue orange 2002-1901 2002-1904 2002-1902 50 50 50 Ǔ 2-conductor ground terminal block green-yellow 2002-1907 50 Ǔ Ǔ 2002 Series Accessories Accessories Other terminal blocks with the same profile: Carrier 2002-1961 Page PageǓ114 47 40 Fuse 2002-1981 Page PageǓ105 Appropriate marking systems: WMB/Marking strips/WMB Inline Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) (see Section 13) End and intermediate plate, 1 mm thick orange 2002-1992 100 (4x25) gray 2002-1991 100 (4x25) Push-in type jumper bar, insulated, IN 25 A, light gray from 1 to 3 2002-433 from 1 to 4 2002-434 from 1 to 5 2002-435 from 1 to 6 2002-436 from 1 to 7 2002-437 from 1 to 8 2002-438 from 1 to 9 2002-439 from 1 to 10 2002-440 200 200 Insulation stop, 100 5 pcs/strip, 100 0.25 - 0.5 mm¤ 100 light gray 2002-171 200 (8x25) 100 Insulation stop, 100 5 pcs/strip, 100 0.75 - 1 mm¤ dark gray 2002-172 200 (8x25) Push-in type jumper bar, insulated, Staggered jumper, Slim style jumper, 4 4 insulated, IN 25 A, IN 25 A, light gray light gray 2-way 2002-402 200 (8x25) 3-way 2002-403 200 (8x25) 2-way 2002-472 100 4-way 2002-404 200 (8x25) 3-way 2002-473 100 5-way 2002-405 100 (4x25) 4-way 2002-474 100 6-way 2002-406 100 (4x25) 5-way 2002-475 50 7-way 2002-407 100 (4x25) 6-way 2002-476 50 8-way 2002-408 100 (4x25) 7-way 2002-477 50 9-way 2002-409 100 (4x25) 8-way 2002-478 50 10-way 2002-410 100 (4x25) 9-way 2002-479 50 10-way 2002-480 50 Push-in type wire jumper, 4 11-way 2002-481 50 insulated, 12-way 2002-482 50 IN 16 A, wire size 1.5 mm¤ L = 60 mm 2009-412 100 (10x10) Adjacent jumper for continuous commoning, L = 110 mm 2009-414 100 (10x10) 4 insulated, I N 25 A, L = 250 mm 2009-416 100 (10x10) light gray 2-way 2002-400 100 Protective warning marker, with high-voltage symbol, black, for 5 terminal blocks yellow 2002-115 100 (4x25) Test plug adapter, for test plug 4 mm gray 2009-174 100 (4x25) (8x25) (8x25) (4x25) (4x25) (4x25) (4x25) Testing tap, (4x25) (4x25) (4x25) (4x25) (4x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) for max. 2.5 mm¤ gray 2009-182 100 (4x25) Modular TOPJOB¥S connector, 4 can be snapped together, for jumper contact slot gray 2002-511 100 (4x25) Spacer module, can be snapped together, e.g., for bridging commoned terminal blocks gray 2002-549 100 (4x25) End plate, for modular TOPJOB¥S connectors, 1.5 mm thick gray 2002-541 100 (4x25) TOPJOB¥S test plug module, 4 can be snapped together gray 2002-611 100 (4x25) Test plug, (4x25) with 500 mm cable, 2 mm red 210-136 50 For list of approvals and user guide, see pages 634 to 637. 45 ? Disconnect Terminal Blocks for Test and Measurement with Movable Knife Disconnect and Through Terminal Blocks, 2002 Series 0.25 – 2.5 (4) 400 V/6 kV/3 IN 16 A 2 AWG 22 – 12 0.25 – 2.5 (4) mm 300 V, 15 A U 400 V/6 kV/3 16 A 600 V, 15 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in AWG 22 – 12 300 V, 15 A U 600 V, 10 A 2 / <___ 33‑mm 1.29 in ___> / <___ 32.9‑mm 1.3 in ___> <___ !1 <______________ 87.5 mm /3.45 in ______________> <______________ 87.5 mm /3.45 in ______________> mm2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in 38.9‑mm / ___> 1.53 in / <___ 33‑mm 1.29 in ___> <___ 38‑mm /1. 49‑in ___> 0.25 – 2.5 (4) mm2 AWG 22 – 12 300 V, 15 A U 400 V/6 kV/3 16 A 600 V, 15 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in <______________ 87.5 mm /3.45 in ______________> 97 ItemPack.-unit No.pcs 4-conductor disconnect terminal block for test and measurement 2002-1871 2002-1874 2002-1872 gray blue orange ItemPack.-unit No.pcs 4-conductor disconnect terminal block for test and measurement with mechanical interlock, with test point, orange disconnect link 2002-1871/401-000 50 gray blue 2002-1874/401-000 50 2002-1872/401-000 50 orange 4-conductor through terminal blocks, same profile as disconnect terminal block End and intermediate plate, 1 mm /0.039 in thick orange 2002-1892100 (4 x 25) gray 2002-1891100 (4 x 25) 1 Conductor sizes: 0.25 mm¤ o 4 Push-in conductor sizes: 0.75 m and 0.75 mm¤ o 2.5 mm¤ iinsulated ferrules, 12 mmw 2 400 V = rated voltage 6 kV = rated surge voltage 3 = pollution degree (see Section 14) 2 400 V = rated voltage 6 kV = rated surge voltage 3 = pollution degree (see Section 14) 3 Strip length, see packaging or instructions. 4 See application notes for: Colored push-in type jumper bars, page 139 Carrier terminaljumper, block with plug in operating Staggered pagedisconnect 141 3 position. Adjacent jumper for continuous commoning, Application example showing a 2-conductor carrier termi4 page 139 End 1 mm /0.039 in thick nal and blockintermediate 2002-1661 withplate, disconnect Push-in type wire jumper, page 140plug orange 2002-1892100 (4 x 25) page 134 TOPJOB¥S connector, plug module, page 136100 (4 x 25) TOPJOB¥S L-type testgray 2002-1891 End and intermediate plate, 1 mm /0.039 in thick orange 2002-1892100 (4 x 25) gray 2002-1891100 (4 x 25) Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Accessories 200 strips Insulation stop, 5 pcs/strip light gray2002-171 0.25-0.5 mm2 dark gray2002-172 0.75-1 mm2 Protective warning marker, for 5 terminal blocks yellow 2002-115 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A 2-way 2002-402200 (8 x 25) 3-way 2002-403200 (8 x 25) 4-way 2002-404200 (8 x 25) 5-way 2002-405100 (4 x 25) : : 10-way 2002-410100 (4 x 25) Slim style jumper, light gray, insulated, IN 25 A 2-way 2002-472100 (4 x 25) 3-way 2002-473100 (4 x 25) 4-way 2002-474100 (4 x 25) 2-conductor disconnect terminal block 50 for test 2002-475 (2 xand 25) 5-way measurement, with knife disconnect and mechanical : : interlock 2002-482 50 (2 x 25) 12-way Open position Push-in type jumper bars, light gray, insulated, IN 25 A Test plug adapter, for test plug 4 mm/0.157 in Ø 2009-174 100 (4 x 25) 215-111 50 Strip length, see packaging or i See application notes for: Colored push-in type jumper ba Staggered jumper, page 141 Adjacent jumper for continuous page 139 Push-in type wire jumper, page TOPJOB¥S connector, page 13 TOPJOB¥S L-type test plug mod 1 - 3 2002-433200 (8 x 25) 1adapter, - 4 2002-434200 (8 x 25) Test plug test plug 4 mm (4 x 25) 1 - 5for2002-435100 2009-174 100 (4x25) : gray : Test plug adapter, 1 - 10 2002-440100 (4 x 25) Testing tap, for max. 2.5 mm2 for test plug 4 mm Testing tap, 2009-182 100 (4 x 25) gray 2009-174 100 (4x25) for max. 2.5 mm¤ Two-way marking adapter, Modular TOPJOB®S connector**, gray 2009-182 100 (4x25) for jumper contact slot Testing tap, pivotable 2002-121 50 (4 x 25) 1 pole 2002-511100 (4 x 25) for max. 2.5 mm¤ Banana plug, gray 2009-182 100 (4x25) for socket 4 mm , mixed 2002-549100 (4 x 25) Spacer, modular color 1 1 Conductor sizes: 0.25 mm¤ o 4 mm¤ is + f-stw; 2002-1801 gray Push-in conductor sizes: 0.75 mm¤ o 4 mm¤ isw mm¤ blue and 0.75 mm¤ o 2.5 2002-1804 iinsulated ferrules, 12 mmw 2002-1802 orange Carrier terminal block with disconnect plug in operating position. Application example showing a 2-conductor carrier terminal block 2002-1661 with disconnect plug Item-specific accessories ItemPack.-unit No.pcs ! 2-conductor disconnect terminal block for testblock and 2-conductor disconnect terminal measurement, with knife disconnect and mechanical for test and measurement, with knife interlock Open position disconnect and mechanical interlock (open position) Banana plug, for socket 4 mm , marker carrier, Test plug, with Double-deck cable 500‑mm /1’7.7’’ color mixed 2-conductor disconnect terminal 2-conductor disconnect terminal block for test and 2-conductor disconnect terminal block for testblock and pivoting 2 mm/0.079 in Ø and mechanical 215-111 50 measurement, with knife disconnect and mechanical gray 2002-121 50 (2x25) measurement, with knife disconnect for test and measurement, with knife interlock interlock red210-136 50 (5 x 10) Double-deck marker carrier, 46 WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 Marking strip, plain, 11 mm wide, 50 m roll Top view 5 pivoting gray 2002-121 Closing of knife disconnect disconnect and mechanical 2-conductor disconnect terminal block interlock for test and knife disconnect and mechanical 50 (2x25) measurement, (closing ofwith knife disconnect) interlock Top view WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 5 2-conductor disconnect termina measurement, with knife discon interlock Closing of knife disconnect ? Double Deck Double Disconnect Terminal Blocks for Test and Measurement with Movable Knife Disconnect, 2002 Series / <___ 42‑mm 1.65 in ___> < _ _ _ 47.5‑mm /1. 87‑in ___> Double-Deck Disconnect Terminal Blocks with Movable Knife Disconnect <______________ 108 mm /4.25 in ______________> ItemPack.-unit No.pcs 4-conductor double deck double disconnect terminal blocks gray blue gray N/L Ciruit: 2002-2951 2002-2954 2002-2952 2 AWG 22 – 12 0.25 – 2.5 (4) mm 300 V, 15 A U 400 V/6 kV/3 16 A 300 V, 15 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in <______________ 108 mm /4.25 in ______________> ItemPack.-unit No.pcs 4-conductor double deck double disconnect terminal blocks, lower deck and upper deck internally commoned on right side and with violet marking block assembly gray Terminal 2002-2958 blue 2002-2959 Circuit: <______________ 108 mm /4.25 in ______________> Item-specific accessories End and intermediate plate, 1 mm /0.039 in thick orange 2002-2992100 (4 x 25) gray 2002-2991100 (4 x 25) Accessories Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) 200 strips Insulation stop, 5 pcs/strip light gray2002-171 0.25-0.5 mm2 dark gray2002-172 0.75-1 mm2 Protective warning marker, for 5 terminal blocks yellow 2002-115100 (4 x 25) Push-in light Testingtype with jumper test plugbars, 2 mm .gray, insulated, IN 25 A Push-in type jumper bars, light gray, insulated, IN 25 A 2-way 2002-402200 (8 x 25) 3-way 2002-403200 (8 x 25) 4-way 2002-404200 (8 x 25) 5-way 2002-405100 (4 x 25) : : 10-way 2002-410100 (4 x 25) Modular TOPJOB®S connector**, for jumper contact slot 1 pole 2002-511100 (4 x 25) 2002-549100 (4 x 25) Spacer, modular 1 Conductor sizes: 0.25 mm Push-in conductor sizes: 0. and 0.75 mm¤ o 2.5 mm¤ iinsulated ferrules, 12 mm ItemPack.-unit 2 No.pcs 4-conductor double deck disconnect terminal blocks, with disconnect on uper deck only, same profile as double 3 deck double disconnect terminal blocks gray 2002-2971 4 blue 2002-2974 gray 2002-2972 N/L Circuit: End and intermediate plate, 1 mm /0.039 in thick orange 2002-2992100 (4 x 25) gray 2002-2991100 (4 x 25) 1 - 3 1 - 4 1 - 5 : 1 - 10 2002-433200 (8 x 25) 2002-434200 (8 x 25) 2002-435100 (4 x 25) : 2002-440100 (4 x 25) Strip length, see packagin See application notes for: Colored push-in type jump Star point jumper, page 1 Delta jumper, page 140 Staggered jumper, page 1 Adjacent jumper for contin page 139 Push-in type wire jumper, p TOPJOB¥S connector, pag TOPJOB¥S L-type test plug Accessories 10 strips wit stretchable 5 plain Test plug, with cable 500‑mm /1’7.7’’ WMB Multi marking syste 2 mm/0.079 in Ø 10 strips wit red210-136 50 (5 x 10) stretchable 5 yellow Slim style jumper , light gray, insulated,inINjumper 25 A Group marker carrier accommodated red contact slot. 2-way 2002-472100 (4 x 25) blue 3-way 2002-473100 (4 x 25) gray 4-way 2002-474100 (4 x 25) orange 5-way 2002-475 50 (2 x 25) light green green : : violet 12-way 2002-482 50 (2 x 25) 100 (4 x 25) Carrier terminal block 2002-2961 with disconnect plug 2002-401 in parked position. 400 V = rated voltage 6 kV = rated surge volta 3 = pollution degree (also see Section 14) End and intermediate plate, 1 mm /0.039 in thick orange 2002-2992100 (4 x 25) gray 2002-2991100 (4 x 25) WMB Multi marking syste Test plug adapter, for test plug 4 mm/0.157 in Ø 2009-174 100 (4 x 25) Testing tap, for max. 2.5 mm2 2009-182 ! / <___ 42‑mm 1.65 in ___> < _ _ _ 47.5‑mm /1. 87‑in ___> 2 AWG 22 – 12 0.25 – 2.5 (4) mm 300 V, 15 A U 400 V/6 kV/3 16 A 300 V, 15 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in / <___ 42‑mm 1.65 in ___> < _ _ _ 47.5‑mm /1. 87‑in ___> 0.25 – 2.5 (4) mm2 AWG 22 – 12 300 V, 15 A U 400 V/6 kV/3 16 A 300 V, 15 A 2 Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in Carrier terminal block 2002-2961 with disconnect plug Carrierinterminal block 2002-2961 with 2002-401 operating position. disconnect plug 2002-401 in operating position. See page 52. WMB Inline, plain, stretchable 5 1,500 WMB white TOPJOB¥S group marker c snap-on type 5 mm wide gray Screwless end stop, for DIN 35 r 6 mm wide gray Screwless end stop, for DIN 35 r 10 mm wide gray 47 ? Fuse Terminal Blocks for (Mini-Automotive) Blade-Type Fuses acc. to DIN 72581-3f, ISO 8820-3, 2002 Series 0.25 — 2.5 (4) 400 V/6 kV/3 IN 10 A AWG 22 — 12 300 V, 10 A U 600 V, 6.3 A 2 Terminal block width 5.2 mm / 0.205 in L 10 — 12 mm / 0.43 in mm2 AWG 22 — 12 300 V, 10 A U 600 V, 6.3 A 2 <________ 66,5 mm/2.61 in _______> Item no. AWG 22 — 12 300 V, 10 A U 600 V, 6.3 A 2 Terminal block width 5.2 mm / 0.205 in L 10 — 12 mm / 0.43 in <________77.9 mm /2.87 in ________> <______________ 87,5 mm/3.45 in _____________> Pack. unit Item no. Pack. unit 4-conductor fuse terminal blocks 2-conductor fuse terminal blocks gray mm2 ( 33 mm/ 1.29 in ) (__ 33 mm/1.29 in _) <__ 38 mm/1.49 in __> Terminal block width 5.2 mm / 0.205 in L 10 — 12 mm / 0.43 in 0.25 — 2.5 (4) 400 V/6 kV/3 IN 10 A 32.9‑mm / 1.3 in ___> mm2 <___ 0.25 — 2.5 (4) 400 V/6 kV/3 IN 10 A 2002-1681 gray 2002-1881 2-conductor fuse terminal blocks gray 2002-1981 Article-specific accessories End and intermediate plate, 1 mm/0.039 in thick orange 2002-1692100 (4 x 25) gray 2002-1691100 (4 x 25) Accessories End and intermediate plate, 1 mm/0.039 in thick orange 2002-1892100 (4 x 25) gray 2002-1891100 (4 x 25) Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Insulation stop, 5 pcs/strip 200 strips Protective warning marker, with high voltage symbol, black, for 5 terminal blocks light gray 2002-171 0.25-0.5 mm2 dark gray 2002-172 0.75-1 mm2 yellow 2002-115 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A Slim style jumpers, light gray, insulated, IN 25 A 2-way 2002-402 200 (8 x 25) 2-way 2002-472 100 (4 x 25) 3-way 2002-403 200 (8 x 25) 3-way 2002-473 100 (4 x 25) 4-way 2002-404 200 (8 x 25) 4-way 2002-474 100 (4 x 25) 5-way 2002-405 100 (4 x 25) 5-way 2002-475 50 (2 x 25) : : : : 10-way 2002-410 100 (4 x 25) 12-way 2002-482 50 (2 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A Test plug adapter, for test plug Ø 4 mm/0.157 in 2009-174 100 (4 x 25) 1 - 3 2002-433 200 (8 x 25) 1 - 4 2002-434 200 (8 x 25) 1 - 5 2002-435 100 (4 x 25) : : 1 - 10 2002-440 100 (4 x 25) Testing tap, for max. 2.5 mm2/AWG 14 2009-182 100 (4 x 25) Two-way marking adapter, Modular TOPJOB®S connector, for jumper contact slot pivotable 1 pole 2002-511 100 (4 x 25) 2002-121 50 (2 x 25) Spacer, modular2002-549 100 (4 x 25) Blade-type fuses acc. to DIN 72581-3f / ISO 8820-3 (contact WAGO) 48 End and intermediate plate, 1 mm/0.039 in thick orange 2002-1992100 (4 x 25) gray 2002-1991100 (4 x 25) Test plug, with cable 500mm/1’7.7’’, Ø 2 mm/0.079 in red 210-136 50 (5 x 10) The rated currents of the fuse cartridges are defined differently in international standards. Due to the different current rating definitions, the recommended current-carrying permanent capacity of the fuses is max. 80% of their rated current according to DIN 72581 part 3 (for an ambient operating temperature of 23°C). Selecting the correct fuse cartrigde is important for product safety within applications as well as the service life/operational reliability of the fuse cartrigdes. Fuse cartrigdes can operate perfectly as protection (break-off point) if they are properly selected and are used in accordance with the manufacturers specifications. In general it is necessary to test fuse cartridges under normal conditions and operational failures within your application. With regard to the product safety, it is in general necessary to test the fuse in the appliance under normal conditions and operational failures. ? TOPJOB¥@ ¥ Blocks Fuse Terminal for2.5 (Mini-Automotive) Blade-Type Fuses 1 TOPJOB Fuse Terminal (4) mm¤ @ Blocks with Indication Additional Seriesor Blocks 1 2002 Fuse Terminal 2.5 (4)Jumper mm¤ Position, 2002 Series 104 AWG 22 — 12 12 V, 22 10- A12U AWG 600 V, 6.3 A 2 Terminal IN 10 A block width 5.2 mm / 0.205 in Terminal block 5.2/ 0.43 mm /in 0.205 in 3 10width - 12 mm L Terminal mmin / 0.205 in L 10 block — 12width mm /5.2 0.43 L 10 - 12 mm / 0.43 in 3 40,8 mm/1.61 in 72,9 mm/2.87 in Circuit I 40,8 mm/1.61 in Circuit II 72,9 mm/2.87 in Circuit I Circuit II Terminal IN 10 A block width 5.2 mm / 0.205 in Terminal 5.2 mm 10 - 12width mm / 0.43 in 3/ 0.205 in L block Terminal block 5.2 mm / 0.205 L 10 —width 12 mm / 0.43 in in L 10 - 12 mm / 0.43 in 3 32,9 mm/1.3 32,9 mm/1.3 in in 38 mm/1.5 38 mm/1.5 in in (4) mm¤ 1 22 - 12 0.25 — 2.5 (4) mm2 AWGAWG 22 — 12 400 V/6 kV/3 2 10 A U 400 (4) mm¤ 1 AWG24 0.25V/6 - 2.5kV/3 22V, - 12 IN 10 A IN400 10 V/6 A kV/3 2 600 V, 6.3 A 2 40,8 mm/1.61 in 72,9 mm/2.87 in Circuit I 40,8 mm/1.61 in Circuit II 72,9 mm/2.87 in Circuit I Circuit II 0.25 - 2.5 (4) mm¤ 1 AWG - 12 0.25 — 2.5 (4) mm2 22 AWG 22 — 12 400 V/6 kV/3 2 400 V/6 (4)kV/3 mm¤ 1 AWG 22 48 0.25 - 2.5 - 12V, 10 A U IN 10 A INV/6 10 kV/3 A 2 600 V, 6.3 A 2 400 Terminal IN 10 A block width 5.2 mm / 0.205 in Terminal 10 - block 12 mmwidth / 0.435.2 in 3mm / 0.205 in L Terminal block 10 width 5.2 mm mm // 0.205 in L — 12 0.43 in L 10 - 12 mm / 0.43 in 3 40,8 mm/1.61 in 72,9 mm/2.87 in Circuit I Circuit I 32,9 mm/1.3 32,9 mm/1.3 in in 38 mm/1.5 38 mm/1.5 in in 0.25 - 2.5 AWG 22 - 12 32,9 mm/1.3 32,9 mm/1.3 in in 38 mm/1.5 38 mm/1.5 in in mm¤ 0.25 - 2.5 Series 2 1 2002 104 2.5 (4)(4)mm 0.25 — 400 V/6 kV/3 2 400 V/6 0.25kV/3 - 2.5 (4) mm¤ 1 IN 10 A IN 10 400 A V/6 kV/3 2 40,8 mm/1.61 in Circuit II 72,9 mm/2.87 in Circuit II Pack. Pack. Pack. Item No. Item No. Unit Unit Unit Pack. Pack. Pack. 2-conductor fuse terminal Itemblock No. for mini-automotive 2-conductor fuse terminal Itemblock No. for mini-automotive 2-conductor fuse terminal Itemblock No. for mini-automotive Unit Unit Unit blade-style fuses, blade-style fuses, blade-style fuses, Item No. Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ 2-conductor block mini-automotive 12V, with test fuse point,terminal with blown fusefor indication by LED, blade-style fuses, LED power consumption: 4.8 mA, gray 12V, with test point, with blown fuse indication by LED, Nominal voltage and current are given by the LED or fuse. LED power fuses, consumption: 4.8 mA, gray protection for Blade-style please note touchproof Nominal 42V and voltage higher. and current are given by the LED or fuse. Blade-style note touchproof protection for Circuit Ifuses, please2002-1981/1000-429 50 42VCircuit and higher. II 2002-1981/1000-449 50 Circuit I 2002-1981/1000-429 50 Circuit II Other terminal blocks2002-1981/1000-449 with the same profile: 50 Ǔ Ǔ Ǔ Ǔ 2-conductor terminal block mini-automotive 24 V, with testfuse point, with blown fusefor indication by LED, blade-style fuses, LED power consumption: 4.8 mA, gray 24 V, with test point, with blown fuse indication by or LED, Nominal voltage and current are given by the LED fuse. LED power fuses, consumption: 4.8 mA, gray protection for Blade-style please note touchproof Nominal 42V and voltage higher. and current are given by the LED or fuse. Blade-style note touchproof protection for Circuit Ifuses, please2002-1981/1000-413 50 42VCircuit and higher. II 2002-1981/1000-434 50 Circuit I 2002-1981/1000-413 50 Circuit II 2002-1981/1000-434 50 Ǔ Ǔ Ǔ Ǔ 2-conductor terminal block mini-automotive 48 V, with testfuse point, with blown fusefor indication by LED, blade-style fuses, LED power consumption: 4.8 mA, gray 48 V, with test point, with blown fuse indication by or LED, Nominal voltage and current are given by the LED fuse. LED power fuses, consumption: 4.8 mA, gray protection for Blade-style please note touchproof Nominal 42V and voltage higher. and current are given by the LED or fuse. Blade-style note touchproof protection for Circuit Ifuses, please2002-1981/1000-414 50 42VCircuit and higher. II 2002-1981/1000-435 50 Circuit I 2002-1981/1000-414 50 Circuit II 2002-1981/1000-435 50 Through 2002-1901 PageǓ102 Other terminal blocks with the same profile: Page 37 Through 2002-1901 PageǓ102 2002 Series Accessories 2002 Series Accessories Accessories End and intermediate plate, 1 mm thick orange 2002-1992 End and intermediate mm thick gray plate, 12002-1991 orange 2002-1992 2002-1991 Insulation stop,gray Appropriate marking systems: WMB/Marking strips/WMB Inline (see Section 13) Appropriate marking systems: WMB/Marking strips/WMB Inline Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Push-in type wire jumper, Staggered jumper, (see Section 13) 100 100 100 100 (4x25) (4x25) (4x25) (4x25) 5 pcs/strip, Insulation stop,0.25 - 0.5 mm¤ 5 pcs/strip, light gray 2002-171 200 (8x25) Insulation stop,0.25 - 0.5 mm¤ light gray 2002-171 200 (8x25) 5 pcs/strip, Insulation stop,0.75 - 1 mm¤ 5 pcs/strip, dark gray 2002-172 200 (8x25) 0.75 -bar, 1 mm¤ Push-in type jumper insulated, gray 2002-172 200 (8x25) 4 Idark N 25 A, Push-in type jumper bar, insulated, light gray 4 I2-way N 25 A, 2002-402 200 (8x25) light gray 3-way 2002-403 200 (8x25) 2-way 2002-402 4-way 2002-404 200 200 (8x25) (8x25) 3-way 2002-403 5-way 2002-405 200 100 (8x25) (4x25) 4-way 2002-404 200 6-way 2002-406 100 (8x25) (4x25) 5-way 2002-405 7-way 2002-407 100 100 (4x25) (4x25) 6-way 2002-406 8-way 2002-408 100 100 (4x25) (4x25) 7-way 2002-407 9-way 2002-409 100 100 (4x25) (4x25) 8-way 2002-408 10-way 2002-410 100 100 (4x25) (4x25) 9-way 2002-409 100 (4x25) For list of approvals and user guide, see pages 634 to 637. 10-way 2002-410 100 (4x25) For list of approvals and user guide, see pages 634 to 637. 4 insulated, Push-in type wire jumper, A, IN 16 4 insulated, wire size 1.5 mm¤ ILN=16 60A,mm 2009-412 100 wire sizemm 1.5 mm¤ L = 110 2009-414 100 LL = = 60 250mm mm 2009-412 2009-416 100 100 L = 110 mm 2009-414 100 L =for 250 mm 2009-416 100 Adjacent jumper continuous commoning, (10x10) (10x10) (10x10) (10x10) (10x10) (10x10) 4 insulated, I N 25 A, Adjacent jumper forgray continuous commoning, light 4 A, insulated, I N 252002-400 2-way 100 light gray Push-in type jumper bar, insulated, 2-way 2002-400 100 IN 25 A, Push-in type jumper bar, insulated, light gray IN 251A,to 3 from 2002-433 200 light from gray 1 to 4 2002-434 200 from 2002-433 from 1 1 to to 3 5 2002-435 200 100 from 2002-434 from 1 1 to to 4 6 2002-436 200 100 from 1 to 5 2002-435 from 1 to 7 2002-437 100 100 from 2002-436 from 1 1 to to 6 8 2002-438 100 100 from 2002-437 from 1 1 to to 7 9 2002-439 100 100 from from 1 1 to to 8 10 2002-438 2002-440 100 100 from 1 to 9 2002-439 100 from 1 to 10 2002-440 100 (4x25) (4x25) (8x25) (8x25) (8x25) (4x25) (8x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) 4 insulated, Slim style jumpers Staggered jumper, IN 25 A, 4 insulated, light gray I2-way N 25 A, light gray 3-way 2-way 4-way 3-way 5-way 4-way 6-way 5-way 7-way 6-way 8-way 7-way 9-way 8-way 10-way 9-way 11-way 10-way 12-way 11-way 12-way Protective warning marker, 2002-472 2002-473 2002-472 2002-474 2002-473 2002-475 2002-474 2002-476 2002-475 2002-477 2002-476 2002-478 2002-477 2002-479 2002-478 2002-480 2002-479 2002-481 2002-480 2002-482 2002-481 2002-482 100 100 100 100 100 50 100 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 (4x25) (4x25) (4x25) (4x25) (4x25) (2x25) (4x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) with high-voltage symbol, black, Protective warning for 5marker, terminal blocks with high-voltage2002-115 symbol, black, yellow 100 (4x25) for 5 terminal blocks yellow 2002-115 100 (4x25) 49 ? Fuse Disconnect Terminal Blocks with Pivotable Fuse Holder for Miniature Metric Fuses 5 x 20 mm, 2002 Series 0.25 — 2.5 (4) mm2 AWG 22 — 12 250 V/6 kV/3 250 V, 6.3 A U IN 6.3 A 250 V, 6.3 A 2 Terminal block width 6.2 mm / 0.244 in L 10 — 12 mm / 0.43 in Item no. Pack. unit 2-conductor fuse terminal block with end plate, without blown fuse indication gray 2002-1611 50 2-conductor fuse terminal block with end plate, with blown fuse indicationby LED gray 12 — 30 V gray 30 — 65 V gray 110 — 250 V 2002-1611/1000-541 2002-1611/1000-542 2002-1611/1000-836 Accessories 50 50 50 Item no. ______> <_______ 87.5mm /3.45in _______> Pack. unit Item no. Pack. unit 2-conductor fuse terminal block with end plate, with additional jumper position, without blown fuse indication gray 2002-1911 50 4-conductor fuse terminal block with end plate, without blown fuse indication 2-conductor fuse terminal block with end plate, with blown fuse indicationby LED 4-conductor fuse terminal block with end plate, with blown fuse indication by LED gray 12 — 30 V gray 30 — 65 V gray 110 — 250 V 2002-1911/1000-541 2002-1911/1000-542 2002-1911/1000-836 50 50 50 gray gray 12 - 30 V gray 30 - 65 V gray 110 - 250 V 2002-1811 2002-1811/1000-541 2002-1811/1000-542 2002-1811/1000-836 50 50 50 50 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) End plate for fuse terminal blocks, 2 mm/0.079 in thick Protective warning marker, with high voltage symbol, black, for 5 terminal blocks gray 2002-991 100 (4x25) yellow 2002-115100 (4 x 25) orange 2002-992 100 (4x25) must be applied individually Insulation stop, 5 pcs/strip 200 strips Push-in type jumper bars, light gray, insulated, IN 25 A 2-way 2004-402200 (8 x 25) light gray 2002-171 0.25-0.5 mm2 3-way 2004-403200 (8 x 25) dark gray 2002-172 0.75-1 mm2 4-way 2004-404200 (8 x 25) must be applied individually 5-way 2004-405100 (4 x 25) : : 10-way 2004-410100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A 1 - 3 2004-433200 (8 x 25) 1 - 4 2004-434200 (8 x 25) 1 - 5 2004-435100 (4 x 25) : : 1 - 10 2004-440100 (4 x 25) 50 <_____ <_____ <_______ 72.9mm /2.87in _______> 57.2mm /2.26 in 57.2mm /2.26 in <_____ 57.2mm /2.26in _____> <_______ 66.5mm /2.62in _______> 0.25 — 2.5 (4) mm2 AWG 22 — 12 250 V/6 kV/3 250 V, 6.3 A U 6.3 A 250 V, 6.3 A 2 Terminal block width 6.2 mm / 0.244 in L 10 — 12 mm / 0.43 in ______> 0.25 — 2.5 (4) mm2 AWG 22 — 12 250 V/6 kV/3 250 V, 6.3 A U 6.3 A 250 V, 6.3 A 2 Terminal block width 6.2 mm / 0.244 in L 10 — 12 mm / 0.43 in WMB Multi Marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-55015 WMB Multi Marking system, plain 10 strips with 10 markers per card, stretchable 5 - 5.2 mm yellow 793-5501/000-002 red 793-5501/000-005 blue 793-5501/000-006 gray 793-5501/000-007 orange 793-5501/000-012 light green 793-5501/000-017 green 793-5501/000-023 violet 793-5501/000-024 5 WMB Inline, plain stretchable 5 - 5.2 mm 1,500 WMB markers, 5mm, on roll white 2009-1151 !1 101 WG 22 - 12 1 57,2 mm/2.25 in mm / 0.244 in 3 in 3 1 Conductor sizes: 0.25 mm¤ o 4 mm¤ is + f-stw; Push-in conductor sizes: 0.75 mm¤ o 4 mm¤ isw and 0.75 mm¤ o 2.5 mm¤ iinsulated ferrule, 12 mmw Fuse terminal blocks with a width of 6.2 mm/0.244 in can be assembled adjacently. If there is no adjacent fuse terminal block at the end of the assembly, an end plate must be used. 2 250 V = rated voltage 6 kV = rated surge voltage 3 = pollution degree (also see Section 14) 3 Strip length, see packaging or instructions. 4 See application notes for: Push-in type wire jumper, page 140 44 in o. Pack. Unit erminal block with mm, D, gray e given by the LED or fuse. n fuse: LED 2 mA 811/1000-541 50 811/1000-542 50 811/1000-836 50 811/1000-867 50 When selecting miniature metric fuses, the maximum power loss listed below should not be exceeded. The power loss is determined according to IEC or EN 609477-3/VDE 0611-6 at 23¡C. The temperature rise of the terminal blocks must be checked according to their application and mounting. Higher ambient temperatures place additional strain on fuse cartridges. Therefore, in such applications, the rated current must be reduced if necessary. More details available from the manufacturer. Pivoting the fuse holder in the locked open position. Miniature metric fuses 5 x 20 Miniature metric fuses 5 x 20 Overload and Series short circuit protection Item No. Series Item No. Overload and short circuit protection Individual Group Short circuit protection only Short circuit protection only Individual Group arrangementGroup arrangement arrangement Individual Individual Grouparrangement argmt. argmt. argmt. argmt. Fuse terminal blocks Fuse terminal blocks 2002-1611 2002-1611 2002-1811 Exchanging fuse. 1.6 W2.5 W 2.5 W 1.61.6 W W 1.6 W 2.5 W 2002-1811 2002-1611/....-.... 2002-1911 1.6 W 1.6 W 2.5 W 2.5 W 2002-1811/....-.... 1.6 W 1.6 W 2.5 W 2002-1811/....-.... 2002-1611/....-.... Protective warning marker and insulation stop must be 2002-1911/....-.... 2.5 W 2.5 W applied individually. Due to the 6.2 mm/0.244 in width of the fuse terminal blocks with pivoting fuse holder, 2004 Protective warning Series jumpers must bemarker used. and insulation stop must be singularized. Due to the 6.2 mm/0.244 in width of the fuse terminal blocks with pivotable fuse holder, 2004 Series jumpers must be used. 51 ? TOPJOB¥@ 2004 Fuse Fuse Plugs Plugs 1 Series 2004 Series on 2002 Series Carrier TerminalBlocks Blocks 114 on 2002 Series Carrier Terminal Fuse plug with pull-tab for miniature metric fuses 5 x 20 mm 250 V / IN 6.3 A Plug width 6.1 mm / 0.24 in Fuse plug with pull-tab for miniature metric fuses 5 x 20 mm 250 V / IN 6.3 A Plug width 6.1 mm / 0.24 in Circuit I Circuit I 009\097\00099798_0.eps 009\097\00099803_0.eps Item No. Pack. Unit Fuse plug with pull-tab, for miniature metric fuses 5 x 20 mm Nominal voltage and current are given by the fuse. Ǔ gray 2004-911 50 Accessories Item No. Ǔ Ǔ Ǔ Ǔ Pack. Unit Fuse plug with pull-tab, for miniature metric fuses 5 x 20 mm, with indicator lamp, gray Nominal voltage and current are given by the LED or fuse. Leakage current in case of blown fuse: LED 2 mA 12 - 30 V 2004-911/1000-541 50 30 - 65 V 2004-911/1000-542 50 120 V 2004-911/1000-867 50 230 V 2004-911/1000-836 50 WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 WMB Multi marking system, plain, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm yellow 793-5501/000-002 red 793-5501/000-005 blue 793-5501/000-006 gray 793-5501/000-007 orange 793-5501/000-012 light green 793-5501/000-017 green 793-5501/000-023 violet 793-5501/000-024 Accessories Appropriate marking systems: WMB/Marking strips systems: WMB/Marking Strips (see pages 96 -101) Accessories Appropriate marking (see Section 13) 2-conductor carrier terminal block, Double-deck carrier terminal block, 1 0.25 - 2.5 (4) mm¤ / AWG 22 - 12 0.25 - 2.5 (4) mm¤ / AWG 22 - 12 Terminal block width 5.2 mm / 0.205 in Terminal block width 5.2 mm / 0.205 in gray 2002-1661 50 L/L 2002-2961 50 End and intermediate plate, 1 mm thick Double-deck carrier terminal block, orange 2002-1692 100 (4x25) 0.25 - 2.5 (4) mm¤ / AWG 22 - 12 gray 2002-1691 100 (4x25) Terminal block width 5.2 mm / 0.205 in L/N 2002-2963 50 End and intermediate plate, 1 mm thick 4-conductor carrier terminal block, 2 orange 2002-2992 100 (4x25) 0.25 - 2.5 (4) mm¤ / AWG 22 - 12 gray 2002-2991 100 (4x25) Terminal block width 5.2 mm / 0.205 in gray 2002-1861 50 End and intermediate plate, 1 mm thick End plate for fuse terminal blocks, orange 2002-1892 100 (4x25) 2 mm thick gray 2002-1891 100 (4x25) orange 2002-992 100 (4x25) gray 2002-991 100 (4x25) 2-conductor carrier terminal block, Shorting link, 5 x 20 mm, 3 0.25 - 2.5 (4) mm¤ / AWG 22 - 12 if the fuse plug is used as disconnect plug IN 6.3 A Terminal block width 5.2 mm / 0.205 in 281-503 250 (10x25) gray 2002-1961 50 Disconnect Plug, End and intermediate plate, 1 mm thick orange 2002-401 100 (4x25) orange 2002-1992 100 (4x25) gray 2002-1991 100 (4x25) Component Plug gray 2002-8xx See pages 67 - 69 For list of approvals and user guide, see pages 634 to 637. 52 Double-deck carrier terminal block, 0.25 - 2.5 (4) mm2/AWG 22-12 L/L 2002-2661 N/L 2002-2662 PE/L 2002-2667 End and Intermediate Plate, 1mm thick orange 2002-2692 gray 2001-2691 5 5 5 5 5 5 5 5 5 5 Technical Information 71 mm/2.79 in 4 1 2 3 Fuse plug dimensions: 1 66.5 mm/2.62 in for 2002-1661 2 87.5 mm/3.45 in for 2002-1861 3 72.9 mm/2.87 in for 2002-1961 4 with inserted fuse plug Using pluggable fuse holders with rail-mount terminal blocks for control circuit protection is highly advantageous for the user since the function and the wiring are accomplished by two separate parts: r No additional cost for assembly and wiring r No risk of accidental contact with live parts during disconnection of fuse plug r If exchanging a defective fuse, the fuse plug is completely separated from the carrier terminal block. This provides safe fuse changeout away from current carrying parts. r The fuse plug can be removed by service personnel, avoiding unintentional reclosing of the circuit by another person. r Quick replacement a fuse by using a prepared istandby plug.i Miniature metric fuses 5 x 20 Series Item No. Overload and short circuit protection Individual argmt. Group argmt. Short circuit protection only Individual argmt. Group argmt. Fuse terminal blocks 2004-911 2004-911/....-.... 1.6 W 1.6 W 2.5 W 2.5 W The following fuse plug features provide quick and safe handling: r Optional LED indicates blown fuse r Marking slot on the fuse plug for clear coordination to the correct carrier terminal block r Two touch-proof test slots r High density with only 6.1 mm/0.24 in width of terminal block/fuse plug r Instead of a fuse, a shorting link may be used as a disconnect plug. 0,9 5,2 N L1 N L2 N L3 Open side of terminal block left Please note: The extra width of the plug (6.1 mm/0.24 in compared to 5.2 mm/0.2 in for carrier terminal blocks) must be compensated for by intermediate plates (1 mm/0.039 in) when building an assembly of carrier terminal blocks equipped with fuse plugs. 53 ? Double-Deck Disconnect Terminal Blocks and Carrier Terminal Blocks 2.5 (4) mm²/AWG 12, 2002 Series 0.25 - 2.5 (4) 400 V/6 kV/3 IN 16 A mm² 0.25 - 2.5 (4) 400 V/6 kV/3 IN 16 A AWG 22 - 12 AWG 22 - 12 Terminal block width 5.2 mm / 0.205 in L 10 - 12 mm / 0.43 in 51,7 mm/2.04 in 51,7 mm/2.04 in 56,4 mm/2.22 in Terminal block width 5.2 mm / 0.205 in L 10 - 12 mm / 0.43 in mm² 93 mm/3.66 in Item No. 93 mm/3.66 in Pack. Unit Item No. Double-deck carrier terminal block, upper deck carrier, gray housing L/L 2002-2661 N/L 2002-2662 50 50 51,7 mm/2.04 in Double-deck disconnect terminal block, with movable knife disconnect, gray housing L/L 50 2002-2671 N/L 50 2002-2672 Pack. Unit 93 mm/3.66 in Item No. Double-deck carrier terminal block, upper deck carrier, gray housing PE/L 2002-2667 Accessories Fuse Plug gray 2004-911 see page 52 Pack. Unit 50 50 Disconnect Plug 2002-401 100 (4x25) orange Component Plug gray 2002-8xx see pages 67-69 54 50 2002 Series Accessories Appropriate marking systems: WMB/Marking strips/WMB Inline (See pages 96 -101) End and intermediate plate, 1 mm thick orange 2002-2692 gray 2002-2691 Double-deck marker carrier, pivoting gray 2002-121 1 1 50 (2x25) Insulation stop, 5 pcs/strip, 0.25 - 0.5 mm² light gray 2002-171 Insulation stop, 5 pcs/strip, 0.75 - 1 mm² dark gray 2002-172 Push-in type jumper bar, insulated, IN 25 A, light gray 2-way 2002-402 3-way 2002-403 4-way 2002-404 5-way 2002-405 6-way 2002-406 7-way 2002-407 8-way 2002-408 9-way 2002-409 10-way 2002-410 Push-in type jumper bar, insulated, IN 25 A, light gray from 1 to 3 2002-433 from 1 to 4 2002-434 from 1 to 5 2002-435 from 1 to 6 2002-436 from 1 to 7 2002-437 from 1 to 8 2002-438 from 1 to 9 2002-439 from 1 to 10 2002-440 200 200 200 100 100 100 100 100 100 (8x25) (8x25) (8x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) 200 200 100 100 100 100 100 100 (8x25) (8x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) Double-deck vertical jumper, insulated, IN 24 A light gray 2002-492 100 (4x25) 200 (8x25) 200 (8x25) ? Double-Deck Terminal Blocks 2.5 (4) mm²/AWG 12 2002 Series mm² 0.25 - 2.5 (4) 500 V/6 kV/3 IN 24 A (28 A) AWG 22 - 12 mm² AWG 22 - 12 Terminal block width 5.2 mm / 0.205 in L 10 - 12 mm / 0.43 in 51,7 mm/2.04 in Terminal block width 5.2 mm / 0.205 in L 10 - 12 mm / 0.43 in 93 mm/3.66 in Item No. 0.25 - 2.5 (4) 500 V/6 kV/3 IN 24 A (28 A) AWG 22 - 12 51,7 mm/2.04 in Terminal block width 5.2 mm / 0.205 in L10 - 12 mm / 0.43 in mm² 51,7 mm/2.04 in 0.25 - 2.5 (4) 500 V/6 kV/3 IN 24 A (28 A) 93 mm/3.66 in Pack. Unit Item No. Through/through terminal block, same profile as double-deck disconnect terminal block without marker carrier, gray housing L/L 50 2002-2601 N/L 50 2002-2602 L/N 50 2002-2603 93 mm/3.66 in Pack. Unit Item No. Through/through terminal block, same profile as double-deck disconnect terminal block without marker carrier, blue housing N/N 50 2002-2604 Pack. Unit Ground conductor/through terminal block, same profile as double-deck disconnect terminal block without marker carrier, gray housing PE/N 50 2002-2647 PE/L 50 2002-2657 93 mm/3.66 in Item No. 93 mm/3.66 in Pack. Unit Item No. 4-conductor through terminal block, same profile as double-deck disconnect terminal block, without marker carrier, internal commoning, conductor entry position colored in violet, gray housing L 50 2002-2608 Accessories 51,7 mm/2.04 in 51,7 mm/2.04 in 51,7 mm/2.04 in Other terminal blocks with the same profile: Carrier 2002-2661 Disconnect 2002-2671 93 mm/3.66 in Pack. Unit 4-conductor through terminal block, same profile as double-deck disconnect terminal block, without marker carrier, internal commoning, conductor entry position colored in violet, blue housing N 50 2002-2609 Item No. Pack. Unit Through/through terminal block, same profile as double-deck disconnect terminal block without marker carrier, internal commoning, green-yellow housing PE 2002-2607 50 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) End and intermediate plate 1 mm thick orange 2002-2692 1 gray 2002-26911 Double-deck marker carrier pivoting gray 2002-121 50 (2 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A 2-way 2002-402200 (8 x 25) 3-way 2002-403200 (8 x 25) 4-way 2002-404200 (8 x 25) 5-way 2002-405100 (4 x 25) : : 10-way 2002-410100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A 1 - 3 2002-433200 (8 x 25) 1 - 4 2002-434200 (8 x 25) 1 - 5 2002-435100 (4 x 25) : : 1 - 10 2002-440100 (4 x 25) Double-deck vertical jumper, insulated, IN 24 A light gray2002-492 100 (4 x 25) 55 ? Double-Deck Fuse Disconnect Terminal Blocks with Pivoting Fuse Holder 2.5 (4) mm²/AWG 12, 2002 Series 0.25 - 2.5 (4) 400 V/6 kV/3 IN 16 A mm² 0.25 - 2.5 (4) 400 V/6 kV/3 IN 16 A AWG 22 - 12 76,4 mm/3.01 in Terminal block width 6.2 mm / 0.244 in L10 - 12 mm / 0.43 in 93 mm/3.66 in Item No. 93 mm/3.66 in Pack. Unit Double-deck fuse disconnect terminal block with pivoting fuse holder, Through/fuse terminal block, for miniature metric fuses 5 x 20 mm, without blown fuse indication Nominal voltage and current are given by the fuse. L/L N/L 2002-2611 2002-2612 AWG 22 - 12 76,4 mm/3.01 in Terminal block width 6.2 mm / 0.244 in L10 - 12 mm / 0.43 in mm² Item No. Double-deck fuse disconnect terminal block with pivoting fuse holder, Through/fuse terminal block, for miniature metric fuses 5 x 20 mm, with blown fuse indication by LED, gray Nominal voltage and current are given by the LED or fuse. Leakage current in case of blown fuse: LED 2mA 12 - 30 V 30 - 65 V 230 V 25 25 Pack. Unit 2002-2611/1000-541 2002-2611/1000-542 2002-2611/1000-836 25 25 25 Protective warning marker and insulation stop must be applied individually. Due to the 6.2 mm/0.244 in width of the fuse terminal blocks with pivoting fuse holder, 2004 Series jumpers must be used. Accessories Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) End and intermediate plate, 1 mm thick Included with above blocks Push-in type jumper bar, insulated, IN 32 A, light gray 2-way 2004-402 3-way 2004-403 4-way 2004-404 5-way 2004-405 6-way 2004-406 7-way 2004-407 8-way 2004-408 9-way 2004-409 10-way 2004-410 Push-in type jumper bar, insulated, IN 32 A, light gray from 1 to 3 2004-433 from 1 to 4 2004-434 from 1 to 5 2004-435 from 1 to 6 2004-436 from 1 to 7 2004-437 from 1 to 8 2004-438 from 1 to 9 2004-439 from 1 to 10 2004-440 56 200 200 100 100 100 100 100 100 100 (8x25) (8x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) 200 200 100 100 100 100 100 100 (8x25) (8x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) End plate for fuse terminal blocks, 2 mm thick orange 2002-1092 100 (4x25) gray 2002-1091 100 (4x25) Insulation stop, 5 pcs/strip, 0.25 - 0.5 mm² light gray 2002-171 200 (8x25) Insulation stop, 5 pcs/strip, 0.75 - 1 mm² dark gray 2002-172 200 (8x25) Pivoting the fuse holder in the locked open position. Protective warning marker, with high-voltage symbol, black, for 5 terminal blocks yellow 2002-115 100 (4x25) Marking strip, plain, 11 mm wide, 50 m roll white 1 2009-110 Double-deck vertical jumper, insulated, IN 24 A light gray 2002-492 100 (4x25) Fuse replacement ? Disconnect Terminal Blocks for Test and Measurement, 6 mm²/AWG 8, for Current and Voltage Transformer Circuits, 2007 Series 0.5 - 6 (10) mm² 500 V/6 kV/3 IN 30 A AWG 20 - 8 99,6 mm/3.92 in Item No. AWG 20 - 8 Terminal block width 8 mm / 0.315 in L 13 - 15 mm / 0.55 in 65,3 mm/2.57 in Terminal block width 8 mm / 0.315 in L 13 - 15 mm / 0.55 in 65,3 mm/2.57 in Terminal block width 8 mm / 0.315 in L 13 - 15 mm / 0.55 in 0.5 - 6 (10) mm² 500 V/6 kV/3 IN 30 A AWG 20 - 8 46,8 mm/1.85 in 0.5 - 6 (10) mm² 500 V/6 kV/3 IN 30 A 99,6 mm/3.92 in Pack. Unit Item No. 2-conductor disconnect terminal block for test and measurement, e.g., current and voltage transformer circuits, with touch-proof test sockets, for 4 mm Ø test plug gray 20 2007-8821 99,6 mm/3.93 in Pack. Unit Item No. 2-conductor disconnect terminal block, with touch-proof test sockets, for 4 mm Ø test plug gray 2007-8811 2-conductor through terminal block, with touch-proof test socket, for 4 mm Ø test plug gray 2007-8801 2-conductor ground terminal block, with touch-proof test socket, for 4 mm Ø test plug 20 Accessories Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) green yellow End and separator plate, 1.5 mm thick, without use of lock-out seal orange 2007-8892 gray 2007-8891 End and separator plate, 1.5 mm thick, for use of lock-out seal orange 2007-8894 gray 2007-8893 Lock-out, for disconnect link yellow 2007-8899 Locking cover, transparent, mechanically locks multiple links 1-pole 50 282-881 2-pole 50 282-882 3-pole 50 282-883 4-pole 50 282-884 5-pole 50 282-885 6-pole 50 282-886 7-pole 50 282-887 8-pole 50 282-888 1 1 1 1 Pack. Unit Adjacent jumper for switch lever, insulated, orange, IN 30 A 2-way 2007-8442 3-way 2007-8443 4-way 2007-8444 5-way 2007-8445 6-way 2007-8446 7-way 2007-8447 8-way 2007-8448 2007-8807 20 20 1 1 1 1 1 1 1 1 (5x10) (5x10) (5x10) (5x10) (5x10) (5x10) (5x10) (5x10) Jumper, insulated, IN 30 A, orange 2-way 50 (5x10) 282-432 3-way 50 (5x10) 282-433 4-way 50 (5x10) 282-434 5-way 50 (5x10) 282-435 6-way 50 (5x10) 282-436 7-way 50 (5x10) 282-437 8-way 50 (5x10) 282-438 9-way 50 (5x10) 282-439 10-way 50 (5x10) 282-440 Jumper with safety lid, insulated, IN 30 A, orange 2-way 282-432/100-000 3-way 282-433/100-000 4-way 282-434/100-000 50 (5x10) Interlocking link, mechanically locks multiple links, 1 m/3’3’’ long transparent 1 210-254 Protective warning marker, with high-voltage symbol, black, for 5 terminal blocks yellow 2006-115 100 (4x25) Jumper, special design, WMB Multi marking system IN 30 A, 10 strips with 10 markers per card, orange for terminal widths 5 - 17.5 mm 1-3-5 plain 793-501 5 1-3-5-7 Marking strip, plain, 11 mm wide, 50 m roll white 2009-110 1 Integrated test sockets for touchproof 4 mm Ø test plugs. Lock-out prevents accidental operation of disconnect link. 282-435/011-000 282-437/011-000 50 (5x10) 57 ? Disconnect and Ground Conductor Terminal Blocks, 6mm2/AWG 8 6 (10) mm2/30 A and Through Terminal Blocks of Same Profile, 2006 Series 0.5 — 6 (10) mm2 800 V/6 kV/3 ➊ IN 30 A AWG 20 — 8 600 V, 30 A, U 600 V, 30 A, 2 Terminal block width 7.5 mm / 0.295 in L 13 — 15 mm / 0.55 in <38,2 mm /1.50 in > <______________ 96,3 mm/3.79 in_______________> 25 25 AWG 20 — 8 600 V, 30 A, 2 Terminal block width 15 mm / 0.59 in L 13 — 15 mm / 0.55 in <38,2 mm/1.50 in > <______________ 96,3 mm /3.79 in_______________> Description 2-conductor disconnect terminal blocks, with testing facility, disconnect link orange gray 2006-1671 blue 2006-1674 0.5 — 6 (10) mm2 500 V/6 kV/3 ➊ IN 30 A mm / <__ 32,9 1.29 in __> <_ 37 mm /1.46 in _> <___ 49 mm /1.93 in___> Terminal block width 7.5 mm / 0.295 in L 13 — 15 mm / 0.55 in AWG 20 — 8 600 V, 30 A, U 600 V, 30 A, 2 mm / <__ 32,9 1.29 in __> 0.5 — 6 (10) mm2 800 V/6 kV/3 ➊ IN 30 A Item no. Pack. unit 2-conductor through terminal blocks, with testing facility, of same shape as disconnect terminal blocks at the left gray 2006-1601 25 blue 2006-1604 25 <38,2 mm /1.50 in > <______________ 96,3 mm /3.79 in_______________> Item no. Ground cond. disconnect term. block, gray 24 V 2006-1671/1000-0848 48 V 2006-1671/1000-0849 120 V 2006-1671/1000-0850 30 V 2006-1671/1000-0851 Accessories Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) 2-conductor disconnect end plates, 1 mm/0.039 in thick orange 2006-1692100 (4 x 25) gray 2006-1691100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 41 A 2-way 2006-402 50 (2 x 25) 3-way 2006-403 50 (2 x 25) 4-way 2006-404 50 (2 x 25) 5-way 2006-405 50 (2 x 25) Protective warning marker, with high voltage symbol, black, for 5 terminal blocks yellow 2006-115 100 (4 x 25) Double-deck marker carrier, pivoting gray 2002-121 50 ( 2 x25) H 2 LED/Neon lamp green T 1 Push-in type jumper bars, light gray, insulated, IN 41 A 1 - 3 1 - 4 1 - 5 2006-433 50 (2 x 25) 2006-434 50 (2 x 25) 2006-435 50 (2 x 25) Marking strip, white, plain 11 mm wide 50 m roll 2009-110 1 H 1 LED/Neon lamp red K 2 K1 Operating condition slide link closed, auxiliary circuit grounded, green lamp illuminates. H 2 LED/Neon lamp green Start point jumper, insulated, WMB Multi marking system, 10 strips with 10 markers per card, IN = IN terminal block, light gray for 5-5.2 mm terminal block width 1-3-5 2006-405/011/000 plain 793-5501 5 50 (2 x 25) T 1 H 1 LED/Neon lamp red K 2 K1 Test condition – no grounding slide link open, auxiliary circuit not grounded. H 2 LED/Neon lamp green T 1 H 1 LED/Neon lamp red K 2 K1 Fault condition – grounding slide link open, auxiliary circuit not grounded, red lamp illuminates. 58 Pack. unit 12 12 12 12 ? Disconnect Terminal Blocks for Test and Measurement 1500 VDC, Carrier/Through Terminal Blocks, 2006 Series (15mm width) 0.5 - 6 (10) mm² AWG 20 - 8 AC/DC 1000 V/ DC 1500 V/12 kV/3 IN 30 A Terminal block width 15 mm / 0.591 in L 13 - 15 mm / 0.55 in Terminal block width 15 mm / 0.591 in L 13 - 15 mm / 0.55 in Terminal block width 15 mm / 0.591 in L 13 - 15 mm / 0.55 in 33 mm/1.3 in 106,9 mm/4.21 in Item No. 33 mm/1.3 in 0.5 - 6 (10) mm² AWG 20 - 8 AC/DC 1000 V/ DC 1500 V/12 kV/3 IN 30 A 59,2 mm/2.33 in 0.5 - 6 (10) mm² AWG 20 - 8 AC/DC 1000 V/ DC 1500 V/12 kV/3 IN 30 A 106,9 mm/4.21 in Pack. Unit Item No. 106,9 mm/4.21 in Pack. Unit Item No. 2-conductor disconnect terminal block for test and measurement, with test point, orange disconnect link gray 12 2006-8671 blue 12 2006-8674 2-conductor carrier terminal block, with test point Accessories Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) gray blue 2006-8661 2006-8664 Pack. Unit 2-conductor through terminal block, with test point, same profile as 2-conductor disconnect terminal block 12 12 gray blue 2006-8601 2006-8604 12 12 WMB Multi marking system, End and intermediate plate, WMB Multi marking system, 10 strips with 10 markers per card, 1 mm thick 10 strips with 10 markers per card, orange 1 stretchable 5 - 5.2 mm 2006-8692 for terminal widths 5 - 17.5 mm plain gray 1 plain 5 793-5501 793-501 2006-8691 WMB Inline, plain, Marking strip, plain, Protective warning marker, stretchable 5 - 5.2 mm, 11 mm wide, with high-voltage symbol, black, 1,500 WMB markers, 5 mm, on roll 50 m roll for 5 terminal blocks white white 1 2009-115 2009-110 yellow 2006-115 100 (4x25) Push-in type jumper bar, insulated, Disconnect plug IN 41 A, orange 2006-8401 48 (4x12) light gray from 1 to 2 50 (2x25) 2006-433 from 1 to 3 50 (2x25) 2006-435 Lockout cap, for conductor entry hole and operating slot gray 25 2006-191 5 1 59 ? TOPJOB¥@ /AWG 8 Fuse Terminal Blocks forfor Automotive Blade-Type FusesFuses 6 (10)6 (10) mm2mm¤ 1 Fuse Terminal Blocks Mini-Automotive Blade-Style 2006 Series Series 110 2006 1 AWG 20 - 8 0.5 - 6 (10) mm¤ 0.5 —500 6 (10) mm22 AWG 20 — 8 V/8 kV/3 500 V/8 kV/3 12 V, 30 A, U N 25 A (30 A) 3 IN 25 IA (30 A) 600 V, 30 A 2 0.5 - 6 (10) mm¤ 2AWG 20 - 8 0.5 — 6 (10) 2mm AWG 20 — 8 500 V/8 V/8 kV/3 500 kV/3 24 V, 30 A, U 25 A A (30 ININ25 (30A) A)3 600 V, 30 A 2 1 38,2 mm/1.5 in Circuit I Circuit II Circuit I 32,9 mm/1.29 in 37,9mm/1.49 in Terminal blockblock width width 7.5 mm7.5 / 0.295 Terminal mm in / 0.295 in 13 - 1513 mm—/ 15 0.55 in 4 L L mm / 0.55 in 32,9 mm/1.29 in 37,9mm/1.49 in 38,2 mm/1.5 in 96,3 mm/3.79 in Terminal block mmmm / 0.295 in in Terminal blockwidth width7.57.5 / 0.295 - 15 / 0.55 in 4 in L 1313 L — mm 15 mm / 0.55 32,9 mm/1.29 in 37,9mm/1.49 in Terminal block width 7.5 mm / 0.295 in Terminal block width 7.5 mm / 0.295 in L 13 - 15 mm / 0.55 in 4 L 13 — 15 mm / 0.55 in 0.5 - 6 (10) mm¤ 1 AWG -8 0.5 — 6 (10) mm2 20AWG 20 — 8 2 500500 V/8 kV/3 V/8 kV/3 48 V, 30 A, U 3 A) IN 25INA25 (30AA)(30 600 V, 30 A 2 38,2 mm/1.5 in 96,3 mm/3.79 in Circuit II Circuit I 96,3 mm/3.79 in Circuit II Pack. Pack. Pack. Item No. Item No. Unit Unit Unit 2-conductor fuse terminal block for automotive mini-automotive 2-conductor fuse terminal block for automotive mini-automotive 2-conductor fuse terminal block for automotive mini-automotive Item No. Ǔ Ǔ blade-style fuses, 12V, with test point, with blown fuse indication by LED, LED power consumption: 4.8 mA, gray Nominal voltage and current are given by the LED or fuse. Blade-style fuses, please note touchproof protection for 42V and higher. Circuit I 2006-1681/1000-429 25 Circuit II 2006-1681/1000-449 25 Ǔ Other terminal blocks with the same profile: 50 Through 2006-1601 PageǓ108 Ǔ Ǔ blade-style fuses, 24V, with test point, with blown fuse indication by LED, LED power consumption: 4.8 mA, gray Nominal voltage and current are given by the LED or fuse. Blade-style fuses, please note touchproof protection for 42V and higher. Circuit I 2006-1681/1000-413 25 Circuit II 2006-1681/1000-434 25 Ǔ Ǔ blade-style fuses, 48V, with test point, with blown fuse indication by LED, LED power consumption: 4.8 mA, gray Nominal voltage and current are given by the LED or fuse. Blade-style fuses, please note touchproof protection for 42V and higher. Circuit I 2006-1681/1000-414 25 Circuit II 2006-1681/1000-435 25 2006 Series Accessories Accessories Appropriate marking systems: WMB/Marking strips Strips (see pages 96 -101) Appropriate marking systems: WMB/Marking (see Section 13) End and intermediate plate, 1 mm thick orange 2006-1692 100 (4x25) gray 2006-1691 100 (4x25) Push-in type jumper bar, insulated, IN 41 A, light gray 2-way 2006-402 3-way 2006-403 4-way 2006-404 5-way 2006-405 50 50 50 50 Push-in type jumper bar, insulated, IN 41 A, light gray from 1 to 3 2006-433 from 1 to 4 2006-434 from 1 to 5 2006-435 50 (2x25) 50 (2x25) 50 (2x25) (2x25) (2x25) (2x25) (2x25) For list of approvals and user guide, see pages 634 to 637. 60 Protective warning marker, with high-voltage symbol, black, for 5 terminal blocks yellow 2006-115 100 (4x25) WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 5 Marking strip, plain, 11 mm wide, 50 m roll white 2009-110 1 Double-deck marker carrier, pivoting gray 2002-121 50 (2x25) End and Intermediate Plate, 2.9 mm thick orange 2006-1696100 (4 x 25) gray 2006-1695100 (4 x 25) Note: Use thicker end plate when using ETA breakers rather than fuses !1 ? Current-Carrying Capacity Curves 111 Terminal width 7.57.5 mmmm / 0.295 in Terminalblock block width / 0.295 in 4 in - 15—mm 0.55/in0.55 L L13 13 15/mm Irat — Displacement % 40 20 10 0 -10 -20 -30 23°C -40 -20 0 20 40 60 1 Conductor sizes: 0.5 mm¤ o 10 mm¤ is + f-stw; Push-in conductor sizes: 1 mm¤ o 10 mm¤ isw and 1.5 mm¤ o 6 mm¤ iinsulated ferrule, 12 mmw 32,9 mm/1.29 in 37,9mm/1.49 in 38,2 mm/1.5 in 1 30 Ambient temperature °C AWG 1 2 6 (10) mm¤ 0.5 AWG 20 - 820 — 8 0.5 - — 6 (10) mm 500 500V/8 V/8kV/3 kV/32 600 V, 30 A, U 3 INN 25 25AA(30 (30A)A) 600 V, 30 A 2 2 500 V = rated voltage 8 kV = rated surge voltage 3 = pollution degree (also see Section 14) 3 LED power consumption: 4.8 mA 96,3 mm/3.79 in 4 Strip length, see packaging or instructions. Current-carrying capacity [A] Ǔ Pack. Item No. Unit 2-conductor fuse terminal block for mini-automotive automotive blade-style fuses, with test point, without blown fuse indication Nominal voltage and current are given by the fuse. Bladestyle fuses, please note touchproof protection for 42V and higher. gray 2006-1681 25 Blade-style fuses (not offered by WAGO) Excess-current circuit-breaker, thermal (not offered by WAGO) Recommended excess-current circuit-breakers from ETA Blade-type fuse cartridges, acc. to DIN 72581-3c/ISO 8820 (contact WAGO) Over-current circuit-breaker, thermal, (contact WAGO) Requires the use of an end plate 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 Commning It 4 Fuse ... A / Cross section ... mm² Individual arrangement 3 2 1 2 3 4 10 A / 2.5 mm² 15 A / 2.5 mm² 20 A / 2.5 mm² 30 A / 4 mm² 1 0 10 20 30 85 75 65 55 Temperature rise 40 45 50 Δ T [K] Ambient operating 45 40 35 temperature [°C] Diagram: Individual arrangement The rated currents of the fuse cartridges are defined differently in international standards. Due to the different current rating definitions, the recommended current-carrying permanent capacity of the fuses is max. 80% of their rated current according to DIN 72581 part 3 (for an ambient operating temperature of 23¡C). Selecting the correct fuse cartridge is important for product safety within applications, as well as for fuse cartridge service life and reliability. Fuse cartridges may be used as protection (break-off point) if they are properly selected and used according to manufacturer specifications. Current-carry capacity [A] 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 Commoning It Fuse ... A / Cross section ... mm² 4 In a group 1 2 3 4 3 2 10 A / 2.5 mm² 15 A / 2.5 mm² 20 A / 4 mm² 25 A / 4 mm² 1 0 10 20 30 85 75 65 55 Temperature rise 40 45 50 Δ T [K] Ambient operating 45 40 35 temperature [°C] Diagram: Block arrangement Information from the mini-automotive blade-type fuse manufacturers FT % Derating Tamb /°C – 25 14 0.877 – 20 13 0.885 – 15 12 0.893 – 10 11 0.901 – 5 10 0.909 0 9 0.917 5 8 0.926 10 6 0.943 15 4 0.962 20 2 0.980 23 0 1.000 30 – 2 1.020 35 – 4 1.042 40 – 6 1.064 45 – 8 1.087 50 – 10 1.111 55 – 13 1.149 60 – 16 1.190 65 – 19 1.235 70 – 22 1.282 Regarding product safety, it is in generally necessary to test fuse cartridges under normal conditions and operational failures within your application. 61 1 Fuse Disconnect Terminal Blocks with Pivoting Fuse Holder for Miniature Metric Fuses 5 x 20 mm, 5 x 30 mm, " x1", 2006 Series 112 ! ! ¥ ? 800 V/8 kV/3 2 @ 600 V, 15 AU 800 V/8 kV/3 2 TOPJOB I 10 A I 10 A Disconnect Terminal Blocks withPivoting PivotingFuse Fuse Holder, 1 Fuse Fuse Disconnect Terminal Blocks with Holder Terminal block width 7.5 mm / 0.295 in Terminal block width 7.5 mm / 0.295 in Miniature Metric Fuses55 20 mm,/ 0.55 5x x 30 mm, 1⁄4" x 1 1⁄4", 2006Series for Miniature Metric Fuses xx20 30 112 for 13 - 15¥mm / 0.55 in 3 13mm, - 15 mm5 in 3 mm, " x1", 2006 Series L L 0.5 - 6 TOPJOB @1 0.5 - 6 (10) mm¤ 2AWG 0.5 - 6 (10) mm¤ 1 2AWG 20 - 8 20 - 8 AWG AWG Fuse Disconnect Blocks with Pivoting Fuse 0.5 — 0.5 — (10)2mm 600 (10)2mm 20 20 — 8 Holder 800 V/86kV/3 800 V/86kV/3 V, Terminal 15 A U— 8 600 V, 15 A U 600 V, 15 A U I800 10 V/8 A kV/3 10 V/8 A kV/3 for Metric 5I800 30V,mm, I 10 Miniature I x A 600 V, 15Fuses A2 1020 A mm, 5 x 600 15 A 2" x1", 2006 Series N N Ǔ Terminal block width mm / 0.295 in 1 7.5 mm¤ 0.5 - 6 (10) AWG 20 - 8/ 0.295 in Terminal block width 7.5 mm mm / 0.55 in 3 L 13 - 15 2 800 V/8 kV/3 600/V,0.55 15 Ain U L 13 — 15 mm IN 10 A Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ 62 N Terminal block width 7.5 mm / 0.295 in L 13 - 15 mm / 0.55 in 3 Ǔ Ǔ N Terminal block width mm / 0.295 in 1 7.5 mm¤ 0.5 - 6 (10) AWG 20 - 8/ 0.295 in Terminal block width 7.5 mm mm / 0.55 in 3 L 13 - 15 2 800 V/8 kV/3 L 13 — 15 mm / 0.55 in IN 10 A 1 Conductor sizes: 0.5 mm¤ o 10 mm¤ is + f-stw; Push-in conductor sizes: 1 mm¤ o 10 mm¤ isw and 1.5 mm¤ o 6 mm¤ iinsulated ferrule, 12 mmw 2 800 V = rated voltage 8 kV = rated surge voltage 3 = pollution degree (see Sectionsizes: 14) 0.5 mm¤ o 10 mm¤ is + f-stw; 1 Conductor conductor sizes: 1 mm¤ o 10 mm¤ isw Strip length, see packaging or instructions. 3 Push-in and 1.5 mm¤ o 6 mm¤ See application for: 4 iinsulated ferrule,notes 12 mmw 96,3 mm/3.79 in 96,3 mm/3.79 in Star point jumper, page 140 2 800 V = rated voltage sizes: 0.5 voltage mm¤ o 10 mm¤ is + f-stw; 1 Conductor 8 kV = rated surge Push-in 1 mm¤ o 10 mm¤ isw Pack. Pack. 3 =conductor pollution sizes: degree Item No. Item No. and 1.5 mm¤ o 6 mm¤ Unit Unit (see Section 14) iinsulated ferrule, 12 mmw 2-conductor fuse disconnect terminal block with 2-conductor fuse disconnect terminal block with 3 Strip length, see packaging or instructions. 2 800 V = rated voltage pivoting fuse holder, pivoting fuse holder, gray, 8 kV = rated surge application notesvoltage for: 4 See 96,3 mm/3.79 in 96,3 mm/3.79 without blown fuse indication with blown fuse indication by LEDin 3 = pollution degree140 Star point jumper, page Nominal voltage and current are given by the fuse. Nominal voltage and current are given by the LED or fuse. (see Section 14) Pack. for miniature metric fuses 5 x 20 mm Leakage current in case of blown fuse: LED 2 mA, Pack. 3 Strip length, see packaging or instructions. Item No. Item No. Unit Unit for miniature metric fuses 5 x 20 mm 4 See application notes for: 96,3 mm/3.79 in 96,3 mm/3.79 in 2-conductor fuse disconnect terminal block with 2-conductor fuse disconnect terminal block with Star point jumper, page 140 pivoting pivoting fuse gray fuse holder, 2006-1611 25 12 - 30 V holder, gray, 2006-1611/1000-541 25 Pack. Pack. without blown fuse indication with30 blown by LED - 65 fuse V indication 2006-1611/1000-542 25 Item No. Item No. Unit Nominal voltage and current are given byUnit the fuse. Nominal are given by the LED or25 fuse. 120 Vvoltage and current 2006-1611/1000-867 Pivoting the fuse holder in the locked open position. for miniature metric fuses 5 x 20terminal mm Leakage in case of blown fuse: LED 2 mA, 230 Vcurrent 2006-1611/1000-836 2-conductor fuse disconnect block with 2-conductor fuse disconnect terminal block with25 for miniature fusesgray, 5 x 20 mm pivoting fuse holder, pivoting fusemetric holder, for miniature fuses 5 x 30 mm for miniature metric fuses 5by x 30 without blownmetric fuse indication with blown fuse indication LEDmm gray voltage and current 2006-1611 25the fuse. 12 - 30 V 2006-1611/1000-541 2006-1621 2006-1621/1000-541 Nominal are given by Nominal voltage and current are given by the LED or25 fuse. 2006-1611/1000-542 30 - 65 V in case 2006-1621/1000-542 for miniature metric fuses 5 x 20 mm Leakage current of blown fuse: LED 2 mA, 25 2006-1611/1000-867 120 V metric fuses2006-1621/1000-867 25 for miniature 5 x 20 mm Pivoting the fuse holder in the locked open position. 2006-1611/1000-836 230 V 2006-1621/1000-836 25 380- 30 - 500 2006-1621/1000-859 gray 2006-1611 25 12 V V 2006-1611/1000-541 25 for miniature metric fuses 5 x 30 mm for miniature 5 x 30 mm 30 - 65 Vmetric fuses2006-1611/1000-542 25 gray 12 - 30 2006-1621/1000-541 for miniature metric fuses2006-1621 1/4" x 11/4" 25 for miniature 1/4" x 11/4" 120 V Vmetric fuses2006-1611/1000-867 25 Pivoting the fuse holder in the locked open position. 30 2006-1621/1000-542 gray 2006-1631 25 12 - 65 30 2006-1631/1000-541 230 V V 2006-1611/1000-836 25 120- 65 V V 2006-1621/1000-867 30 2006-1631/1000-542 25 230 V metric fuses2006-1631/1000-867 2006-1621/1000-836 120 25 for miniature metric fuses 5 x 30 mm for miniature 5 x 30 mm 380- 30 - 500 2006-1621/1000-859 230 V 2006-1631/1000-836 gray 2006-1621 25 12 V V 2006-1621/1000-541 25 380- 65 - 500 2006-1631/1000-859 30 V V 2006-1621/1000-542 25 for miniature metric fuses 1/4" x 11/4" for miniature 1/4" x 11/4" 120 V metric fuses2006-1621/1000-867 25 gray Series Accessories 2006-1631 25 12 - 30 2006-1631/1000-541 230 V V 2006-1621/1000-836 25 2006 30 - 65 V V 2006-1631/1000-542 380 - 500 2006-1621/1000-859 25 Appropriate marking systems: WMB/Marking strips 120 V 2006-1631/1000-867 25 (see Section 13) V metric fuses2006-1631/1000-836 230 25 for miniature metric fuses 1/4" x 11/4" for miniature 1/4" x 11/4" 380- 30 - 500 V 2006-1631/1000-859 Endgray and intermediate2006-1631 plate, 1 mm thick Push-in type bar, insulated, 25 12 V jumper 2006-1631/1000-541 25 Opening the cover to replace the fuse. orange 2006-1692 100 (4x25) 30 - 65 V IN 41 A,2006-1631/1000-542 25 gray 2006-1691 100 (4x25) light gray 120 V 2006-1631/1000-867 25 2006 Series Accessories Accessories from 1 2006-1631/1000-836 to 3 230 V 25 Appropriate marking systems: WMB/Marking strips 2006-433 50 (2x25) 1 2006-1631/1000-859 to 4 96 2006-434 50 (2x25) End plate for fuse terminal blocks, 380 - 500 V from 25 Appropriate marking systems: WMB/Marking Strips (see pages -101) (see Section 13) from 1 to 5 2006-435 50 (2x25) 2 mm thick End andSeries intermediate plate, 12006-992 mm thick orange 100 (4x25) Push-in type jumper bar, insulated, 2006 Accessories Opening the cover to replace the fuse. orange 2006-1692 IN 41 A, gray 2006-991 100 (4x25) Appropriate marking systems: WMB/Marking strips gray bar, insulated, 2006-1691 100 (4x25) Protective warning light gray Push-in type jumper marker, (see Section 13) from 1 to 3 2006-433 IN 41 A, with high-voltage symbol, black,50 (2x25) from to 4insulated, 2006-434 50 (2x25) plateintermediate for fuse lightterminal gray for 5 1terminal blocks End and plate,blocks, 1 mm thick Push-in type jumper bar, from to 5 2006-435 50 (4x25) (2x25) Opening the cover to replace the fuse. 2 mm thick 2-way 2006-402 100 50 (4x25) (2x25) 2006-115 100 orange 2006-1692 Iyellow N 411A, orange 2006-992 100 3-way 2006-403 50 (4x25) (2x25) Test plug, gray 2006-1691 light gray gray 2006-991 100 (4x25) 4-way 2006-404 50 (2x25) with 500 from 1 to mm 3 cable, 2006-433 50 (2x25) Push-in type bar, insulated, 5-way 2006-405 50 (2x25) Protective warning 2 mmmarker, from 1to 4 2006-434 50 (2x25) End plate forjumper fuse terminal blocks, 41 A, IN mm with high-voltage symbol, black,50 (2x25) red 210-136 50 from 1 to 5 2006-435 2 thick lightinsulated, gray for 5 terminal system,blocks Star point jumper, orange 2006-992 100 (4x25) WMB Multi marking 4 2006-402 50 (4x25) (2x25) yellow 10 strips with 102006-115 markers per 100 card,(4x25) light gray I2-way gray 2006-991 100 N = IN terminal block, 3-way 2006-403 50 (2x25) Protective Test plug, warning stretchable 5 - 5.2 mm 1-3-5 bar, insulated, 2006-405/011-000 Push-in type jumper marker, 2006-404 50 (2x25) 500 mm cable, plainhigh-voltage 793-5501 5 I4-way with symbol, black, N 41 A, 5-way 2006-405 50 (2x25) 2 mm light gray for 5 terminal blocks For list of approvals and user guide, see pages 634 to 637. red 210-136 50 2-way 2006-402 50 (2x25) yellow 2006-115 100 (4x25) WMB Multi marking system, Star point jumper, insulated, 2006-403 3-way 50 (2x25) Test plug, 4 10 strips 10 markers per card, light gray50 (2x25) IN = IN terminal block, 4-way 2006-404 with 500 with mm cable, stretchable 1-3-5 2006-405/011-000 5-way 2006-405 50 (2x25) 2 mm 5 - 5.2 mm 50 (2x25) plain 793-5501 5 red 210-136 50 Starlistpoint jumper,and insulated, For of approvals user guide, see pages 634 to 637. WMB Multi marking system, 4 10 strips with 10 markers per card, IN = IN terminal block, light gray stretchable 5 - 5.2 mm 1-3-5 2006-405/011-000 50 (2x25) plain 793-5501 5 Terminal block width 7.5 mm / 0.295 in L 13 - 15 mm / 0.55 in 3 N 59 mm/2.32 in (10) mm¤ 1 AWG 20 - 8 59 mm/2.32 in 59 mm/2.32 in 112 N 59 mm/2.32 in 1 0.5 - 6 59 mm/2.32 in 59 mm/2.32 in (10) mm¤ 1 AWG 20 - 8 ? TOPJOB¥@ Fuse Blockswith withPivoting PivotingFuse FuseHolder Holder, FuseDisconnect Disconnect Terminal Terminal Blocks for Fuses " ¼"xx1", 1¼",2006 2006 Series forMiniature Miniature Metric Fuses Series 0.5 - 6 (10) mm¤ 1 AWG 20 - 8 AWG 20 — 8 0.5 V/8 — 6kV/3 (10)2mm2600 800 V, 15 AU 800 V/8 kV/3 600 V, 15 A U IN 10 A IN 10 A 600 V, 15 A 2 0.5 - 6 Terminal block width 10.4 mm / 0.409 in Terminal block width 10.4 mm / 0.409 in L 13 - 15 mm / 0.55 in 3 113 (10) mm¤ 1 AWG 20 - 8 0.5 6 kV/3 (10)2mm2 800— V/8 800 V/8 IN 10 A kV/3 IN 10 A !1 AWG 20 — 8 600 V, 15 A U 600 V, 15 A 2 1 Terminal block width 10.4 mm / 0.409 in Terminal block width 10.4 mm / 0.409 in L 13 - 15 mm / 0.55 in 3 59 mm/2.32 in L 13 — 15 mm / 0.55 in 59 mm/2.32 in L 13 — 15 mm / 0.55 in 1 Conductor sizes: 0.5 mm¤ o 10 mm¤ is + f-stw; Push-in conductor sizes: 1 mm¤ o 10 mm¤ isw and 1.5 mm¤ o 6 mm¤ iinsulated ferrule, 12 mmw 2 800 V = rated voltage 8 kV = rated surge voltage 3 = pollution degree (see Section 14) 3 Strip length, see packaging or instructions. 96,3 mm/3.79 in Pack. Unit Item No. gray 2006-1631/099-000 25 Pack. Unit Item No. Fuse disconnect terminal block with pivoting fuse holder and end plate, gray, with blown fuse indication by LED Nominal voltage and current are given by the LED or fuse. Leakage current in case of blown fuse: LED 2 mA, for miniature metric fuses 1/4" x 11/4" Fuse disconnect terminal block with pivoting fuse holder and end plate, without blown fuse indication Nominal voltage and current are given by the fuse. for miniature metric fuses 1/4" x 11/4" Ǔ 4 See application notes for: Star point jumper, page 140 96,3 mm/3.79 in Ǔ Ǔ Ǔ Ǔ Ǔ 12 - 30 V 30 - 65 V 120 V 230 V 380 - 500 V 2006-1631/1099-541 2006-1631/1099-542 2006-1631/1099-867 2006-1631/1099-836 2006-1631/1099-859 25 25 25 25 25 2006 Series Accessories Accessories Appropriate marking systems: WMB/Marking strips Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) (see Section 13) End plate for fuse terminal blocks, 2 mm thick 2006-992 orange gray 2006-991 Push-in type jumper bar, insulated, IN 25 A, light gray from 1 to 3 2002-433 from 1 to 5 2002-435 from 1 to 7 2002-437 from 1 to 9 2002-439 100 (4x25) 100 (4x25) 200 100 100 100 (8x25) (4x25) (4x25) (4x25) Star point jumper, insulated, 4 IN = IN terminal block, light gray 1-3-5 2002-405/011-000 100 (4x25) Protective warning marker, with high-voltage symbol, black, for 5 terminal blocks yellow 2006-115 100 (4x25) WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 5 Test plug, with 500 mm cable, 2 mm red 210-136 50 For list of approvals and user guide, see pages 634 to 637. Screwless end stop, for DIN 35 rail, 6 mm wide gray 249-116 Screwless end stop, for DIN 35 rail, 10 mm wide gray 249-117 Pivoting fuse holder with spare fuse holders Protective warning markers must be applied individually. Due to the 10.4 mm/0.409 in width of the fuse terminal blocks with pivoting fuse holder, 2002 Series jumpers must be used. Miniature metric fuses 100 (4x25) Series Item No. Overload and short circuit protection Individual argmt. 50 (2x25) 2006-1611 7.5 2006-1621 7.5 2006-1631 7.5 2006-1631 /099-... 10.4 2006-1631 /1099-... 10.4 Group argmt. Short circuit protection only Individual argmt. Group argmt. Fused disconnect terminal blocks 1.6 W 1.6 W 2.5 W 2.5 W 1.6 W 1.6 W 2.5 W 2.5 W 1.6 W 1.6 W 2.5 W 2.5 W 2.5 W 2.5 W 2.5 W 2.5 W 2.5 W 2.5 W 2.5 W 2.5 W When selecting miniature metric fuses, the maximum power loss listed below should not be exceeded. The power loss is determined according to IEC or EN 609477-3/VDE 0611-6 at 23¡C. The temperature rise of the terminal blocks must be checked according to their application and mounting. Higher ambient temperatures represent an additional impact on miniature metric fuses. Therefore, in such applications the rated current must be reduced if necessary. More details are available from the fuse manufacturer. 63 ? TOPJOB¥@ TOPJOB¥@ Carrier Blocks 1 Fuse 1Terminal FusePlugs Plugs and on Carrier Terminal FuseBlocks Plugs 6on(10) Carrier mm¤Terminal Blocks 6 (10) mm¤ 2006 Series 2006 Series 2006 Series 116 116 Fuse plug with pull-tab Fuse plug with pull-tab Fuse plug with pull-tab Fuse plug with pull- 800 V / IN 10 A Plug width 7.4 mm / 0.291 in 800 V / IN 10 A Plug width 7.4 mm / 0.291 in 800 V / IN 10 A Plug width 10.4 7.4 mm mm/ /0.291 0.409inin 800 V / IN 10 A Plug width 10.4 mm Circuit I Circuit I Circuit I Circuit I 011\051\00115171_0.eps 011\051\00115211_0.eps 011\051\00115171_0.eps 011\051\00115201_0.eps 011\051\00115211_0.eps 011\051\00115201_0.eps Item No. Pack. Unit Item No. gray 2006-911 Pack. Unit Ǔ 25 Ǔ Ǔ Ǔ 12 gray- 30 V 30 - 65 V 120 V 230 V 2006-911/1000-541 2006-911 25 2006-911/1000-542 2006-911/1000-867 2006-911/1000-836 25 25 25 25 Ǔ for miniature metric fuses 5 x 30 mm gray 2006-921 Ǔ 25 Ǔ Ǔ Ǔ Ǔ for miniature metric fuses 1/4" x 11/4" gray 2006-931 25 Ǔ Ǔ Ǔ Ǔ Ǔ Item-Specific Accessories End and intermediate plate, 1 mm thick orange 2006-1692 gray 2006-1691 Accessories fuse plugs Accessories Item No. for miniature metric fuses 5 x 30 mm 12 gray- 30 V 2006-921/1000-541 2006-921 25 30 - 65 V 2006-921/1000-542 120 V 2006-921/1000-867 230 V 2006-921/1000-836 380 - 500 V 2006-921/1000-859 25 25 25 25 25 pull-tab, gray, Fuse plug with pull-tab with indicator lamp Nominal voltage and current are given by the fuse. Nominal voltage and current given by the LED or fuse. for miniature metric fuses 1/4"are x 11/4" Leakage current in case of blown fuse: LED 2 mA, for miniature metric fuses 5 x 20 mm Ǔ Ǔ Ǔ Ǔ gray 12 - 30 V 30 - 65 V 120 V 230 V 2006-931/099-000 2006-911/1000-541 2525 2006-911/1000-542 25 2006-911/1000-867 25 2006-911/1000-836 25 Fuse plug with pull-ta Nominal voltage and cu for miniature metric fuse Ǔ gray Ǔ Ǔ Ǔ Ǔ Ǔ for miniature metric fuses 5 x 30 mm 12 - 30 V 2006-921/1000-541 30 - 65 V 2006-921/1000-542 120 V 2006-921/1000-867 230 V 2006-921/1000-836 380 - 500 V 2006-921/1000-859 25 25 25 25 25 for miniature metric fuses 1/4" x 11/4" 12 - 30 V 2006-931/1000-541 30 - 65 V 2006-931/1000-542 120 V 2006-931/1000-867 230 V 2006-931/1000-836 380 - 500 V 2006-931/1000-859 25 25 25 25 25 for miniature metric fuses 1/4" x 11/4" 12 gray- 30 V 2006-931/1000-541 2006-931 25 30 - 65 V 2006-931/1000-542 120 V 2006-931/1000-867 230 V 2006-931/1000-836 380 - 500 V 2006-931/1000-859 25 25 25 25 25 Item-Specific Accessories 100 (4x25) 100 (4x25) Pack. Pack. Unit Unit Ǔ Fuse plug with pull-tab pull-tab, gray, with indicator lamp Nominal voltage and current are given by the fuse. Nominal voltage and current aremm given by the LED or fuse. for miniature metric fuses 5 x 20 Leakage current in case of blown fuse: LED 2 mA, for miniature metric fuses 5 x 20 mm Fuse plug with pull-tab Nominal voltage and current are given by the fuse. for miniature metric fuses 5 x 20 mm Ǔ Pack. Unit End and intermediate plate, 1 mm thick orange 2006-1692 gray 2006-1691 Ǔ Ǔ Ǔ Ǔ Ǔ Item-Specific Accessories 100 (4x25) 100 (4x25) Intermediate End and intermediate plate, 2.9plate, mm thick 1 mm thick orange 2006-1696 2006-1692 gray 2006-1695 2006-1691 Item-Specific Acc 100 (4x25) 100 (4x25) Intermediate plate, 2. orange gray Accessories fuse plugs Appropriate marking systems: WMB/Marking strips Appropriate systems: strips Appropriate marking systems: WMB/Marking Stripsmarking (see pages 96WMB/Marking -101) (see Section 13) (see Section 13) Screwless end5stop, Screwless end stop, End plate for fuse terminal blocks, Shorting End platelink, for fuse 5 x 20 terminal mm, blocks, Shorting link, x 20 mm, for DIN rail,is used as disconnect plug for DIN 2 mm thick if2 the mmfuse thickplug is used as disconnect plug if the fuse35plug Iorange IN mm 6.3 wide A 6 6 mm w orange 2006-992 100 (4x25) 281-503 2006-992 250 100(10x25) (4x25) 281-503 250 100(10x25) (4x25) 249-116 N 6.3 A 10 mm wide gray 2006-991 100 (4x25) gray 2006-991 100 (4x25) gray 249-116 100 (4x25) gray 249-117 2-conductor carrier terminal block, 2-conductor carrier terminal system, block, Screwless WMB Multiend marking stop, system, Screwless end stop, WMB MultiPlug marking Disconnect 0.5 - 6 (10) mm¤ / AWG 20 - 8 10 0.5 strips - 6 (10) withmm¤ 102006-401 markers / AWG per 20 100 -card, 8 (4x25) for 10 DIN strips35 with rail, 10 markers per card, for DIN orange Terminal block width 7.5 mm / 0.295 in stretchable Terminal block 5 - 5.2 width mm7.5 mm / 0.295 in 10 stretchable mm wide5 - 5.2 mm 10 mm gray 2006-1661 25 plain gray 793-5501 2006-1661 25 5 gray plain 249-117 793-5501 50 (2x25) 5 gray For list of approvals and user guide, see pages 634 to 637. For list of approvals and user guide, see pages 634 to 637. 64 116 !1 Fuse Plugs and Carrier Terminal Blocks, 2006 SeriesFuse plug with pull-tab Fuse plug with pull-tab Fuse plug with pull-tab 800 V / IN 10 A Fuse plug with pull-tab Plug width 7.4 mm / 0.291 in 800 V / IN 10 A 800 V / IN 10 A The following features of the fuse plug ensure quick and Using pluggable fuse holders with rail-mounted terminal Plug 7.4 circuit mm /protection 0.291 inis highly advantageous Plug width 10.4 mm / 0.409 in safe use: blockswidth for control 117 r Optional LED indicates blown fuse r Markable fuse plug for clear coordination to the correct carrier terminal block r Two touch-proof test slots r High density with only 7.5 mm/0.295 in width of terminal block and fuse plug width 7.4 (10.4) mm r Instead of a fuse, a shorting link may be used as a disconnect plug for the user, as the function and the wiring are accomplished by two separate parts: r No additional cost for assembly and wiring r No risk of accidental contact with live parts during disconnection of fuse plug r If exchanging a defective fuse, the fuse plug is completely separated from the carrier terminal block. This provides changeout away from current carrying parts. r The fuse plug can be removed by service personnel, avoiding unintentional reclosing of the circuit by another person r Quick replacement a fuse by using a prepared istandby plug.w 800 V / IN 10 A Plug width 10.4 mm / 0.409 in Circuit I Circuit I 011\051\00115211_0.eps 011\051\00115201_0.eps Circuit I 1 Circuit I 011\051\00115171_0.eps 011\052\00115241_0.eps Miniature metric fuse Series Item No. Item No. Ǔ Pack. Unit Item No. Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ 12 - 30 V 2006-931/1099-541 30 - 65 V 2006-931/1099-542 for miniature metric fuses 5 x 30 mm 120 V 2006-931/1099-867 gray 2006-921 25 230 V 2006-931/1099-836 380 - 500 V 2006-931/1099-859 25 25 25 25 25 Pack. Unit Fuse plug dimensions 12 - 30 V 2006-911/1000-541 30 - 65 V 2006-911/1000-542 120 V 2006-911/1000-867 230 V 2006-911/1000-836 25 25 25 25 for miniature metric fuses 5 x 30 mm 12 - 30 V 2006-921/1000-541 30 - 65 V 2006-921/1000-542 120 V 2006-921/1000-867 230 V 2006-921/1000-836 0,1 7,5 380 - 500 V 2006-921/1000-859 25 25 25 25 25 for miniature metric fuses 1/4" x 11/4" 12 - 30 V 2006-931/1000-541 30 - 65 V 2006-931/1000-542 120 V 2006-931/1000-867 230 V 2006-931/1000-836 380 - 500 V 2006-931/1000-859 25 25 25 25 25 Overload and short circuit protection Individual argmt. Fuse plug with pull-tab, gray, with indicator lamp Nominal voltage and current are given by the LED or fuse. Leakage current in case of blown fuse: LED 2 mA, for miniature metric fuses 5 xmm/3.79 20 mm in 93,3 Fuse plug with pull-tab Nominal voltage and current are given by the fuse. Pack. No. for miniature metric fusesItem 5 x 20 mm Unit Fuse plug with pull-tab, gray, with indicator lamp Nominal voltage and current are given by the LED or fuse. gray 2006-911 25 Leakage current in case of blown fuse: LED 2 mA, for miniature metric fuses 1/4" x 11/4" 72 mm/2.83 in 1 TOPJOB¥@ Fuse Plugs on Carrier Terminal Blocks 6 (10) mm¤ ? 2006 Series Group argmt. Short circuit protection only Individual argmt. Group argmt. Pack. FusedNo. disconnect terminal blocks Item 2006-911 7.5 1.6 W 1.6 W 2.5 W Unit 2.5 W 2006-921 7.5pull-tab 1.6 W 1.6 W 2.5 W 2.5 W Fuse plug with 2006-931 7.5 1.6 W 1.6 W 2.5 W 2.5 W Nominal voltage and current are given by the fuse. for 2006-931 miniature metric fuses 1/4" x 11/4" /099-... 10.4 2006-931 /1099-... 10.4 Ǔ gray 2.5 W 2.5 W 2.5 W 2.5 W 2.5 W 2.5 W 2.5 W 2.5 W 2006-931/099-000 25 Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ for miniature metric fuses 1/4" x 11/4" gray 2006-931 25 Ǔ Ǔ Ǔ Ǔ Ǔ Item-Specific Accessories End and intermediate plate, 1 mm thick orange 2006-1692 gray 2006-1691 Item-Specific Accessories 100 (4x25) 100 (4x25) Intermediate plate, 2.9 mm thick Accessoriesorange fuse plugs2006-1696 gray 2006-1695 Item-Specific Accessories Item-Specific Accessories End and intermediate plate, N L1 N 1 L2 mm N thick L3 orange 2006-1692 100 (4x25) gray 2006-1691 100 (4x25) Open side of terminal block left Intermediate plate, 2.9 mm thick orange 2006-1696 gray 2006-1695 100 (4x25) When using the 10.4 mm/0.409 in wide plug, Appropriate marking systems: WMB/Marking strips please note: 100 (4x25) The extra width of the plug (10.4 mm/0.409 in compared (see Section 13) to 7.5 mm/0.295 in for carrier terminal blocks) must be compensated plates (2.9 mm) when Screwless end stop, End plate for fuse terminal blocks, Shorting link,for 5 xby20intermediate mm, building an assembly carrier terminal equipped for DIN 35 rail, 2 mm thick if the of fuse plug is used asblocks disconnect plug with fuse plugs. IN 6.3 A 6 mm wide orange 2006-992 100 (4x25) 281-503 250 (10x25) gray 2006-991 100 (4x25) gray 249-116 2-conductor carrier terminal block, WMB Multi marking system, Screwless end stop, 10 strips with 10 markers per card, for DIN 35 rail, 0.5 - 6 (10) mm¤ / AWG 20 - 8 stretchable 5 - 5.2 mm 10 mm wide Terminal block width 7.5 mm / 0.295 in gray 2006-1661 25 plain 793-5501 5 gray 249-117 100 (4x25) 100 (4x25) 100 (4x25) 50 (2x25) For list of approvals and user guide, see pages 634 to 637. 65 Component Plugs, Diode and LED Modules Carrier Version Jumper Version 53,3 mm/2.1 in Component plugs are available for carrier terminal blocks and for insertion into adjacent jumper slots. Empty component plugs can be custom configured with component or small PCB. In addition, pre-configured diode or LED modules are available. Custom configurations are available on request. 1 2 3 AC/DC Marking with WMB markers or with continuous marking strip 66 Testing can be peformed with 2-pole test plugs ? Plug-In Component Module for Carrier Terminal Block, 2002 Series Diode Module; Diode 1N 4007 UN 250 V; URM 1000 V; 1 A max. LED IF 25 mA LED Module: IN ≤ 5,6 mA; IF ≤ 25 mA Width 5.2 mm / 0.205 in Width 5.2 mm / 0.205 in Item No. Pack Unit Item No. Pack Unit Empty Module, 5.2 mm wide, 2002-800100 LED Module, 5.2 mm wide, with red LED AC/DC 12 - 30 V 2002-800/1000-541 100 Diode Module, 5.2 mm wide, Diode 1N 4007 2002-800/1000-411100 LED Module, 5.2 mm wide, with red LED AC/DC 30 - 65 V 2002-800/1000-542 100 LED Module, 5.2 mm wide, with red LED AC/DC 110 - 250 V 2002-800/1000-836 100 Accessories 2-Conductor Terminal Block, ➊ 0.25 – 2.5 (4) mm2/AWG 22 –12 width 522 mm /0.205 in gray 2002-166150 End and Intermediate Plate, 1 mm thick orange 2002-1692100 (4 x 25) gray 2002-1691100 (4 x 25) Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Push-In Type Jumper, light gray, insulated, IN 25 A 2-Conductor Carrier Terminal Block, ➊ 0.25 – 2.5 (4) mm2/AWG 22 –12 width 5.2 mm /0.205 in gray 2002-166150 End and Intermediate Plate, 1 mm thick orange 2002-1692100 (4 x 25) gray 2002-1691100 (4 x 25) 2-way 2002-402 200 (8 x 25) 3-way 2002-403 200 (8 x 25) 4-way 2002-404 200 (8 x 25) 5-way 2002-405 100 (4 x 25) 6-way 2002-406 100 (4 x 25) 7-way 2002-407 100 (4 x 25) 8-way 2002-408 100 (4 x 25) 4-Conductor Carrier Terminal Block, ➋ 4-Conductor Carrier Terminal Block, ➋ 2002-409 100 (4 x 25) 0.25 – 2.5 (4) mm2/AWG 22 –12 0.25 – 2.5 (4) mm2/AWG 22 –12 9-way 10-way 2002-410 100 (4 x 25) width 5.2 mm /0.205 in width 5.2 mm /0.205 in gray 2002-186150 gray 2002-186150 Push-In Type Jumper, light gray, insulated, IN 25 A End and Intermediate Plate, 1 mm thick End and Intermediate Plate, 1 mm thick orange 2002-1892100 (4 x 25) orange 2002-1892100 (4 x 25) 1 - 3 2002-433 200 (8 x 25) gray 2002-1891100 (4 x 25) gray 2002-1891100 (4 x 25) 1 - 4 2002-434 200 (8 x 25) 1 - 5 2002-435 100 (4 x 25) Insulation Stop, 5 pcs/strip 200 Strips Insulation Stop, 5 pcs/strip 200 Strips 1 - 6 2002-436 100 (4 x 25) light gray2002-171 0.25-0.5 mm2 light gray2002-171 0.25-0.5 mm2 1 - 7 2002-437 100 (4 x 25) dark gray2002-172 0.75-1 mm2 dark gray2002-172 0.75-1 mm2 1 - 8 2002-438 100 (4 x 25) 1 - 9 2002-439 100 (4 x 25) Test Plug Adapter, for test plug 4 mm Ø, Test Plug, for test plug 4 mm Ø, 1 - 10 2002-440 100 (4 x 25) 2009-174 100 (4 x 25) 2009-174 100 (4 x 25) Slim Style Jumpers, light gray, insulated, IN 25 A Testing Tap, for max. 2.5 mm² 2002-472 100 (4 x 25) 2009-182 100 (4 x 25) 2-way 3-way 2002-473 100 (4 x 25) 4-way 2002-474 100 (4 x 25) 5-way 2002-475 50 (2 x 25) Protective Warning Marker, high voltages symbol, 5-way 2002-476 50 (2 x 25) for 5 terminal blocks 2002-477 50 (2 x 25) yellow 2002-115 100 (4 x 25) 5-way 5-way 2002-478 50 (2 x 25) 5-way 2002-479 50 (2 x 25) 5-way 2002-480 50 (2 x 25) ➊ 66.5 mm / 2.62 in (2-Conductor) 5-way 2002-481 50 (2 x 25) ➋ 87.5 mm / 3.45 in (4-Conductor) 12-way 2002-482 50 (2 x 25) Testing Tap, for max. 2.5 mm² 2009-182 100 (4 x 25) Protective Warning Marker, high voltages symbol, for 5 terminal blocks yellow 2002-115 100 (4 x 25) ➊ 66.5 mm / 2.62 in (2-Conductor) ➋ 87.5 mm / 3.45 in (4-Conductor) 67 ? Plug-In Component Module for Terminal Jumper Location, 2002 Series Diode Module; Diode 1 N 4007 UN 250 V; URM 1000 V; 1 A max. LED-Module: IN ≤ 5,6 mA; IF ≤ 25 mA Width 10.4 mm / 0,409 in Width 10.4 mm / 0.409 in Item No. Empty Module, 10.4 mm wide, 2002-880 Item No. Pack Unit Pack Unit LED Module, 10.4 mm wide, with red LED AC/DC 12 - 30 V + AC/DC 2002-880/1000-541 50 50 _ LED Module, 10.4 mm wide, with red LED AC/DC 30 - 65 V + AC/DC 2002-880/1000-542 50 Diode Module, 10.4 mm wide, Diode 1N 4007 2002-880/1000-411 50 _ LED Module, 10.4 mm wide, with red LED AC/DC 110 - 250 V + AC/DC 2002-880/1000-836 50 _ Accessories Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) 2-Conductor Terminal Block, ➊ 0.25 – 2.5 (4) mm2/AWG 22 –12 width 5.2 mm /0.205 in gray 2002-1201100 End and Intermediate Plate, 0.8 mm thick orange 2002-1292100 (4 x 25) gray 2002-1291100 (4 x 25) 2-Conductor Terminal Block, ➊ 0.08 – 2.5 (4) mm2/AWG 28 –12 width 5.2 mm /0.205 in gray 2002-1201100 End and Intermediate Plate, 0.8 mm thick orange 2002-1292100 (4 x 25) gray 2002-1291100 (4 x 25) 3-Conductor Terminal Block, ➋ 0.25 – 2,5 (4) mm2/AWG 22 –12 width 5.2 mm /0.205 in gray 2002-1301100 End and Intermediate Plate, 0.8 mm thick orange 2002-1392100 (4 x 25) gray 2002-1391100 (4 x 25) 3-Conductor Terminal Block, ➋ 0.08 – 2.5 (4) mm2/AWG 28 –12 width 5.2 mm /0.205 in gray 2002-1301100 End and Intermediate Plate, 0.8 mm thick orange 2002-1392100 (4 x 25) gray 2002-1391100 (4 x 25) 4-Conductor Terminal Block, ➌ 0.25 – 2.5 (4) mm2/AWG 22 –12 width 5.2 mm /0.205 in gray 2002-1401100 End and Intermediate, 0.8 mm thick orange 2002-1492100 (4 x 25) gray 2002-1491100 (4 x 25) 4-Conductor Terminal Block, ➌ 0.08 – 2.5 (4) mm2/AWG 28 –12 width 5.2 mm /0.205 in gray 2002-1401100 End and Intermediate Plate, 0.8 mm thick orange 2002-1492100 (4 x 25) gray 2002-1491100 (4 x 25) ➊ 48.5 mm / 1.91 in (2-Conductor) ➋ 59.5 mm / 2.34 in (3-Conductor) ➌ 70.0 mm / 2.76 in (4-Conductor) 68 ? ! TOPJOB @ Component Plug Housings on Carrier Terminal Blocks 2.5 (4) mm2 1 Empty Empty Component Plug Housings on Carrier Terminal Blocks 2.5 (4) mm¤ 2002 Series Series 132 2002 ¥ Empty component plug housing Empty component plug housing Plug width 5.2 mm / 0.205 in (1 Watt Max.) Plug width 10.4 mm / 0.409 in (2 Watt Max.) 1 Length of 2002-1661: 66.5 mm / 2.62 in 2-conductor carrier terminal block 2 Length of 2002-1861: 87.5 mm / 3.45 in 4-conductor carrier terminal block 3 Length of 2002-1961: 72.9 mm / 2.87 in 2-conductor carrier terminal block with additional jumper position 4 See application notes for: Colored push-in type jumper bars, page 139 Staggered jumper, page 141 Push-in type wire jumper, page 140 Item No. Ǔ Pack. Unit Empty component plug housing type 1, 2-pole, 5.2 mm wide gray 2002-800 100 Item No. Ǔ Pack. Unit Accessories Empty component plug housing type 2, 2-pole, 10.4 mm wide gray 2002-810 50 Ǔ Empty component plug housing type 3, 4-pole, 10.4 mm wide gray 2002-820 50 Carrier Term. Blocks and Accessories Accessories Appropriate marking system: Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) WMB/Marking strips Push-in type wire jumper, 2-conductor carrier terminal block, 1 4 insulated, 0.25 - 2.5 (4) mm¤ / AWG 22 - 12 IN 16 A, Terminal block width 5.2 mm / 0.205 in wire size 1.5 mm¤ gray 2002-1661 50 End and intermediate plate, 1 mm thick L = 60 mm 2009-412 100 (10x10) orange 2002-1692 100 (4x25) L = 110 mm 2009-414 100 (10x10) L = 250 mm 2009-416 100 (10x10) gray 2002-1691 100 (4x25) 4-conductor carrier terminal block, Push-in type jumper bar, insulated, 2 4 0.25 - 2.5 (4) mm¤ / AWG 22 - 12 IN 25 A, light gray Terminal block width 5.2 mm / 0.205 in gray 2002-1861 50 2-way 2002-402 End and intermediate plate, 1 mm thick 3-way 2002-403 orange 2002-1892 100 (4x25) 4-way 2002-404 5-way 2002-405 gray 2002-1891 100 (4x25) 6-way 2002-406 7-way 2002-407 2-conductor carrier terminal block, 3 8-way 2002-408 0.25 - 2.5 (4) mm¤ / AWG 22 - 12 9-way 2002-409 Terminal block width 5.2 mm / 0.205 in 10-way 2002-410 gray 2002-1961 50 End and intermediate plate, 1 mm thick Push-in type jumper bar, insulated, orange 2002-1992 100 (4x25) IN 25 A, gray 2002-1991 100 (4x25) light gray from 1 to 3 2002-433 from 1 to 4 2002-434 Insulation stop, from 1 to 5 2002-435 5 pcs/strip, from 1 to 6 2002-436 0.25 - 0.5 mm¤ from 1 to 7 2002-437 light gray 2002-171 200 (8x25) from 1 to 8 2002-438 Insulation stop, from 1 to 9 2002-439 5 pcs/strip, from 1 to 10 2002-440 0.75 - 1 mm¤ dark gray 2002-172 200 (8x25) Protective warning marker, Multi-purpose operating tool, with high-voltage symbol, black, for component plugs for 5 terminal blocks 2002-116 yellow 2002-115 100 (4x25) For list of approvals and user guide, see pages 634 to 637. 200 200 200 100 100 100 100 100 100 (8x25) (8x25) (8x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) 200 200 100 100 100 100 100 100 (8x25) (8x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) Slim style jumper Staggered jumper, 4 insulated, IN 25 A, light gray 2-way 3-way 4-way 5-way 6-way 7-way 8-way 9-way 10-way 11-way 12-way 2002-472 2002-473 2002-474 2002-475 2002-476 2002-477 2002-478 2002-479 2002-480 2002-481 2002-482 100 100 100 50 50 50 50 50 50 50 50 (4x25) (4x25) (4x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) (2x25) WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 WMB Multi marking system, plain, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm yellow 793-5501/000-002 red 793-5501/000-005 blue 793-5501/000-006 gray 793-5501/000-007 orange 793-5501/000-012 light green 793-5501/000-017 green 793-5501/000-023 violet 793-5501/000-024 5 5 5 69 Technical Information Technical Information 1 133 53,3 mm/2.1 in 1 1 2 3 <______________ 25,8‒27 ______________> Ø max.* * max. 3.4 mm at 5.2 mm module width and * max. 5.4 mm at 10.4 mm/0.409 in module width Notice: Reconnection only possible with similar or larger wire diameter. Smaller wire diameters must be soldered. Component plugs for building custom circuits. Solder-free assembly of diodes, resistors, etc. Picture shows 1N4007 diode. 1±0,075 <__ 5 __> Plugging a diode module into a through terminal block. Diode module inserted in a through terminal block. <___ 6 ___> <________________ 19 ±0,2 ________________> <____ When closing the cover, please insert cover as shown in the illustration. <____ 6 ____> <_________ 12 +0,2 –0,1 _________> Dimensions of self-assembled PCBs Module height 2 mm at 5.2 mm module width and module height 3.3 mm at 10.4 mm module width Cutting component to the proper length. 70 Pressing component into plug contact via operating tool. Pushing PCB into plug contact via operating tool. > Opening the cover via multi-purpose operating tool for component plugs. > max. 15,5 < Ø 0,5‒1,1 _> <______ Application example showing a pluggable diode module. Diode terminal blocks These double and triple deck diode terminal blocks have been specially developed for custom diode circuits such as lamp test and collective fault signal circuits. Using LED terminal blocks, monitoring units can be designed for control and operating circuits. The terminal blocks provide high density wiring maintaining a width of only 5.2 mm. Using push-in type jumper bars opens up additional possibilities when designing custom circuits. Custom configurations with diodes, resistor or LEDs available on request. Polarized diode gate, common cathode Double deck diode terminal blocks + + ++ – Lamp test circuit Triple deck diode terminal blocks Open diode gate, can be connected individually. Using push-in type jumper bars, individual levels can be turned into polarized diode gates. 71 ? Diode Terminal Blocks 1.5 (2.5) mm2 / AWG 14 and LED Terminal Blocks 1.5 (2.5) mm2 / AWG 14; 2001 Series 0.25 – 1.5 (2.5) mm2 AWG 22 – 14 UN 250 V; URM 1000 V 1 N 4007 - 0.5 A continuous current 0.25 – 1.5 (2.5) mm2 AWG 22 – 14 UN 250 V; URM 1000 V 1 N 4007 - 0.5 A continuous current 0.25 – 1.5 (2.5) DC 24 V IF0.025 A max. Terminal block width 4.2 mm / 0.165 in L 9 – 11 mm / 0.39 in Terminal block width 4.2 mm / 0.165 in L 9 – 11 mm / 0.39 in Terminal block width 4.2 mm / 0.165 in L 9 – 11 mm / 0.39 in mm2 AWG 22 – 14 can be connected: 0.25 mm2 - 4 mm2 "s+f-st"; can be pushed in directly; 0.5 mm2 - 2.5 mm2 "s" and 0.75 mm2 - 1.5 mm2 "insulated ferrule, 12 mm/0.472 in" 72 ItemPack.-unit No.pcs ItemPack.-unit No.pcs 2-cond. diode term. blocks with diode 1 N 4007 2001-1211/1000-410 100 Circuit I, gray Circuit II, gray 2001-1211/1000-411 100 ItemPack.-unit No.pcs 3-cond. diode term. blocks with diode 1 N 4007 2001-1311/1000-410 100 Circuit I, gray Circuit II, gray 2001-1311/1000-411 100 3-cond. LED term. blocks with red LED, 24 V DC 2001-1321/1000-434 100 Circuit I, gray Circuit II, gray 2001-1321/1000-413 100 Through terminal block with the same shape gray 2001-1201 End and intermediate plate, 0.8 mm/0.032 in thick orange 2002-1292 100 (4x25) gray 2002-1291 100 (4x25) Through terminal block with the same shape gray 2001-1301 End and intermediate plate, 0.8 mm/0.032 in thick orange 2002-1392 100 (4x25) gray 2002-1391 100 (4x25) Through terminal block with the same shape gray 2001-1301 End and intermediate plate, 0.8 mm/0.032 in thick orange 2002-1392 100 (4x25) gray 2002-1391 100 (4x25) ItemPack.-unit No.pcs 4-cond. diode term. blocks with diode 1 N 4007 2001-1411/1000-410 100 Circuit I, gray Circuit II, gray 2001-1411/1000-411 100 4-cond. LED term. blocks with red LED, 24 V DC 2001-1421/1000-434 100 Circuit I, gray Circuit II, gray 2001-1421/1000-413 100 Through terminal block with the same shape gray 2001-1401 End and intermediate plate, 0.8 mm/0.032 in thick orange 2002-1492 100 (4x25) gray 2002-1491 100 (4x25) Through terminal block with the same shape gray 2001-1401 End and intermediate plate, 0.8 mm/0.032 in thick orange 2002-1492 100 (4x25) gray 2002-1491 100 (4x25) ItemPack.-unit No.pcs ? Diode Terminal Blocks 2.5 mm2 (4) mm2 / AWG 12 and LED Terminal Blocks 2.5 (4) mm2 / AWG 12; 2002 Series 0.25 –2.5 (4) mm2 AWG 22 – 12 UN 250 V; URM 1000 V 1 N 4007 – 0.5 A continuous current 0.25 –2.5 (4) mm2 AWG 22 – 12 UN 250 V; URM 1000 V 1 N 4007 – 0.5 A continuous current 0.25 –2.5 (4) mm2 DC 24 V IF 0.025 A max. Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in AWG 22 – 12 can be connected: 0.25 mm2 - 4 mm2 "s+f-st"; can be pushed in directly; 0.75 mm2 - 4 mm2 "s" and 0.75 mm2 - 2.5 mm2 "insulated ferrule, 12 mm/0.472 in" ItemPack.-unit No.pcs ItemPack.-unit No.pcs 2-cond. diode term. blocks with diode 1 N 4007 2002-1211/1000-410 100 Circuit I, gray Circuit II, gray 2002-1211/1000-411 100 ItemPack.-unit No.pcs 3-cond. diode term. blocks with diode 1 N 4007 2002-1311/1000-410 100 Circuit I, gray Circuit II, gray 2002-1311/1000-411 100 3-cond. LED term. blocks with red LED, 24 V DC 2002-1321/1000-434 100 Circuit I, gray Circuit II, gray 2002-1321/1000-413 100 Through terminal block with the same shape gray 2002-1201 End and intermediate plate, 0.8 mm/0.032 in thick orange 2002-1292 100 (4x25) gray 2002-1291 100 (4x25) Through terminal block with the same shape gray 2002-1301 End and intermediate plate, 0.8 mm/0.032 in thick orange 2002-1392 100 (4x25) gray 2002-1391 100 (4x25) Through terminal block with the same shape gray 2002-1301 End and intermediate plate, 0.8 mm/0.032 in thick orange 2002-1392 100 (4x25) gray 2002-1391 100 (4x25) ItemPack.-unit No.pcs 4-cond. diode term. blocks with diode 1 N 4007 2002-1411/1000-410 100 Circuit I, gray Circuit II, gray 2002-1411/1000-411 100 4-cond. LED term. blocks with red LED, 24 V DC 2002-1421/1000-434 100 Circuit I, gray Circuit II, gray 2002-1421/1000-413 100 Through terminal block with the same shape gray 2002-1401 End and intermediate plate, 0.8 mm/0.032 in thick orange 2002-1492 100 (4x25) gray 2002-1491 100 (4x25) Through terminal block with the same shape gray 2002-1301 End and intermediate plate, 0.8 mm/0.032 in thick orange 2002-1492 100 (4x25) gray 2002-1491 100 (4x25) ItemPack.-unit No.pcs 73 ? Double Deck Diode Terminal Blocks / Double Deck LED Terminal Blocks 2.5 mm2/4 mm2 / AWG 12, 2002 Series 0.25 –2.5 (4) mm2 AWG 22 – 12 UN 250 V; URM 1000 V 1 N 4007 – 0.5 A continuous current 0.25 –2.5 (4) mm2 AWG 22 – 12 UN 250 V; URM 1000 V 1 N 4007 – 0.5 A continuous current Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in 2 “s + f-st“; c an be connected: 0.25 mm2 – 4 mm can be pushed in directly: 0 and .75 mm22 – 4 mm2 “s“ 2 <_12 _> <____ 70 mm /2.76 in ____> Through terminal blocks with the same shape see page 37 Description Double deck diode terminal block and double deck LED terminal block, for DIN 35 rail Accessories End and intermediate plate Push-in type jumper bars, light gray, insulated, IN 25 A Push-in type jumper bars, light gray, insulated, IN 25 A Two-way marking adapter, pivotable < 52 mm /2.05 in > < 52 mm /2.05 in > 0.75 mm – 2.5 mm “insulated ferrule, 12 mm“ I <____ 70 mm /2.76 in ____> II I Item Pack. unit No.pcs Double deck diode terminal blocks with diode 1 N 4007 Circuit ‑I, gray 2002-2211/1000-0410 50 Circuit II, gray 2002-2211/1000-0411 50 II Item Pack. unit No.pcs Double deck diode terminal blocks with 2 diodes 1 N 4007 Circuit ‑I, gray 2002-2214/1000-0492 50 Circuit II, gray 2002-2214/1000-0491 50 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) 0.8 mm /0.031 in thick 2002-2292 orange gray 2002-2291 2002-402 2-way 2002-403 3-way 2002-404 4-way 2002-405 5-way : : 2002-410 10-way 2002-433 1 - 3 2002-434 1 - 4 2002-435 1 - 5 : : 2002-440 1 - 10 0.8 mm /0.031 in thick 2002-2292 orange gray 2002-2291 2002-402 2-way 2002-403 3-way 2002-404 4-way 2002-405 5-way : : 100 (4 x 25) 10-way 2002-410 200 (8 x 25) 1 - 3 2002-433 200 (8 x 25) 1 - 4 2002-434 100 (4 x 25) 1 - 5 2002-435 : : 100 (4 x 25) 1 - 10 2002-440 100 (4 x 25) 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 2002-121 50 (2 x 25) 100 (4 x 25) 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 2002-121 50 (2 x 25) Examples of circuit configuration + – + Used as recovery diodes 74 – + – + + Used in lamp test circuit ++ – ? Double Deck Diode Terminal Blocks / Double Deck LED Terminal Blocks 2.5 mm2/4 mm2 / AWG 12, 2002 Series 0.25 –2.5 (4) mm2 AWG 22 – 12 UN 250 V; URM 1000 V 1 N 4007 – 0.5 A continuous current 0.25 –2.5 (4) mm2 DC 24 V IF 25 mA max. Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in <____ 70 mm /2.76 in ____> I <____ 70 mm /2.76 in ____> II I <____ 70 mm /2.76 in ____> I – II – + Item Pack. unit No.pcs Double deck diode terminal blocks with 2 diodes 1 N 4007 Circuit ‑I, gray 2002-2213/1000-0487 50 Circuit II, gray 2002-2213/1000-0488 50 Accessories 0.8 mm /0.031 in thick 2002-2292 orange gray 2002-2291 2002-402 2-way 2002-403 3-way 2002-404 4-way 2002-405 5-way : : 2002-410 10-way AWG 22 – 12 < 52 mm /2.05 in > < 52 mm /2.05 in > < 52 mm /2.05 in > 0.25 –2.5 (4) mm2 AWG 22 – 12 UN 250 V; URM 1000 V 1 N 4007 – 0.5 A continuous current Item Pack. unit No.pcs Double deck diode terminal blocks with 2 diodes 1 N 4007 Circuit ‑I, gray 2002-2214/1000-0489 50 Circuit II, gray 2002-2214/1000-0490 50 II + + + – – Item Pack. unit No.pcs Double deck LED terminal blocks with red LED, DC 24 V 2002-2221/1000-0434 50 Circuit ‑I, gray Circuit II, gray 2002-2221/1000-0413 50 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) 100 (4 x 25) 0.8 mm /0.031 in thick 2002-2292 orange gray 2002-2291 2002-402 2-way 2002-403 3-way 2002-404 4-way 2002-405 5-way : : 2002-410 10-way 100 (4 x 25) 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 0.8 mm /0.031 in thick 2002-2292 orange gray 2002-2291 2002-402 2-way 2002-403 3-way 2002-404 4-way 2002-405 5-way : : 100 (4 x 25) 10-way 2002-410 100 (4 x 25) 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 1 - 3 1 - 4 1 - 5 : 1 - 10 2002-433 2002-434 2002-435 : 2002-440 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 1 - 3 1 - 4 1 - 5 : 1 - 10 2002-433 2002-434 2002-435 : 2002-440 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 1 - 3 1 - 4 1 - 5 : 1 - 10 2002-433 2002-434 2002-435 : 2002-440 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 2002-121 50 (2 x 25) 2002-121 50 (2 x 25) 2002-121 50 (2 x 25) + + + Used in lamp test circuit + + – + + + + + Used for collective fault indication – – + – + – + Used for voltage indication 75 ? Triple Deck Diode Terminal Blocks / Triple Deck LED Terminal Blocks 2.5 mm2/4 mm2 / AWG 12, 2002 Series 0.25 –2.5 (4) mm2 AWG 22 – 12 UN 250 V; URM 1000 V 1 N 4007 – 0.5 A continuous current 0.25 –2.5 (4) mm2 AWG 22 – 12 UN 250 V; URM 1000 V 1 N 4007 – 0.5 A continuous current Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in 2 “s + f-st“; c an be connected: 0.25 mm2 – 4 mm can be pushed in directly: 0 .75 mm2 – 4 mm2 “s“ and 0.75 mm2 – 2.5 mm2 “insulated ferrule, 12 mm“ <___ 69,5 mm /2.74 in ___> <___ 69,5 mm /2.74 in ___> <________ 93,5 mm /3.68 in ________> Through terminal blocks with the same shape see page 40 Description Triple deck diode terminal block and Triple deck LED terminal block, for DIN 35 rail I Accessories End and intermediate plate Push-in type jumper bars, light gray, insulated, IN 25 A Push-in type jumper bars, light gray, insulated, IN 25 A Three-way marking adapter, pivotable 76 <________ 93,5 mm /3.68 in ________> II I Item Pack. unit No.pcs Triple deck diode terminal blocks with diode 1 N 4007 Circuit ‑I, gray 2002-3211/1000-0410 50 Circuit II, gray 2002-3211/1000-0411 50 <_12 _> II Item Pack. unit No.pcs Triple deck diode terminal blocks with diode 1 N 4007 Circuit ‑I, gray 2002-3211/1000-0675 50 Circuit II, gray 2002-3211/1000-0676 50 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) 0.8 mm /0.031 in thick 2002-3292 orange gray 2002-3291 2002-402 2-way 2002-403 3-way 2002-404 4-way 2002-405 5-way : : 2002-410 10-way 2002-433 1 - 3 2002-434 1 - 4 2002-435 1 - 5 : : 2002-440 1 - 10 2002-131 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 0.8 mm /0.031 in thick 2002-3292 orange gray 2002-3291 2002-402 2-way 2002-403 3-way 2002-404 4-way 2002-405 5-way : : 2002-410 10-way 2002-433 1 - 3 2002-434 1 - 4 2002-435 1 - 5 : : 2002-440 1 - 10 50 (2 x 25) 100 (4 x 25) 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 2002-131 100 (4 x 25) 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 50 (2 x 25) ? Triple Deck Diode Terminal Blocks / Triple Deck LED Terminal Blocks 2.5 mm2/4 mm2 / AWG 12, 2002 Series 0.25 –2.5 (4) mm2 AWG 22 – 12 UN 250 V; URM 1000 V 1 N 4007 – 0.5 A continuous current 0.25 –2.5 (4) mm2 DC 24 V IF 25 mA max. Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in Terminal block width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in <___ 69,5 mm /2.74 in ___> <___ 69,5 mm /2.74 in ___> AWG 22 – 12 <________ 93,5 mm /3.68 in ________> I <________ 93,5 mm /3.68 in ________> II I Item Pack. unit No.pcs Triple deck diode terminal blocks with 3 diodes 1 N 4007 Circuit ‑I, gray 2002-3212/1000-0673 50 Circuit II, gray 2002-3212/1000-0674 50 Item Pack. unit No.pcs Triple deck LED terminal blocks with red LED, DC 24 V 2002-3221/1000-0434 50 Circuit ‑I, gray Circuit II, gray 2002-3221/1000-0413 50 Accessories 0.8 mm /0.031 in thick 2002-3292 orange gray 2002-3291 2002-402 2-way 2002-403 3-way 2002-404 4-way 2002-405 5-way : : 2002-410 10-way 1 - 3 1 - 4 1 - 5 : 1 - 10 II Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) 0.8 mm /0.031 in thick 100 (4 x 25) orange 2002-3292 100 (4 x 25) gray 2002-3291 200 (8 x 25) 2-way 2002-402 200 (8 x 25) 3-way 2002-403 200 (8 x 25) 4-way 2002-404 100 (4 x 25) 5-way 2002-405 : : 100 (4 x 25) 10-way 2002-410 100 (4 x 25) 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 2002-433 2002-434 2002-435 : 2002-440 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 1 - 3 1 - 4 1 - 5 : 1 - 10 2002-433 2002-434 2002-435 : 2002-440 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 2002-131 50 (2 x 25) 2002-131 50 (2 x 25) 77 TOPJOB®S is pluggable: with X-COM® and X-COM®-MINI-Terminal Blocks Slide the locking latch into the desired position. 5.2 mm 3.5 mm Plugs can be locked individually. 78 Coding pins can be used to protect against mis-mating. Series 2020 The female plugs have an integrated end plate. As a result, an end plate must be added to the last base terminal in that section. To code the female plug, first remove the desired coding finger. X-COM®S terminal blocks use the same jumper system as the TOPJOB®S terminal blocks allowing them to be jumpered together (e.g. see terminal #16 X-COM®S and terminal #17 TOPJOB®S). TOPJOB®S test plug adapters can also be used with series 2020 and 2022. X-COM®S terminal blocks can be snapped together to form groups. Individual terminal blocks can also be removed via the actuation tool. The notches shown above allow the terminal blocks to be easily separated. Terminal blocks in both the series 2020 and 2022 can be jumpered together as the jumper locations align. Both base terminal blocks and female plugs are touch safe. Additional marking available with adapter. 79 X-COM®-SYSTEM MINI 1-Conductor/1-Pin Receptacle Terminal Blocks; 2-Conductor/2-Pin Receptacle Terminal Blocks, 1.0 (1.5)mm2/AWG 16, 2020 Series 32,5 mm / __> 1.28 in 0.14 – 1 (1.5) mm2 AWG 24 – 16 500 V/6 kV/3 300 V, 10 A U IN 13.5 A* 300 V, 10 A 2 Terminal block width 3.5 mm / 0.137 in L 9 – 11 mm / 0.39 in <__ mm / <__ 32,5 1.28 in __> 0.14 – 1 (1.5) mm2 AWG 24 – 16 500 V/6 kV/3 300 V, 10 A U IN 13.5 A* 300 V, 10 A 2 Terminal block width 3.5 mm / 0.137 in L 9 – 11 mm / 0.39 in (28,6mm/1.13in) <__ 48,5 mm /1.91 in __> <__ 46,9 mm/1.85 in __> <____________ 85,2 mm /3.35 in ____________> Description 1-conductor/1-pin receptacle terminal block, suitable for DIN 35 rail acc. to EN 60715 1-conductor/1-pin receptacle terminal block gray 2020-1201100 blue 2020-1204100 2-conductor/2-pin receptacle terminal block gray 2020-1401100 blue 2020-1404100 1-conductor/1-pin ground receptacle terminal block green-yellow 2020-1207100 2-conductor/2-pin ground receptacle terminal block green-yellow 2020-1407100 2-conductor/2-pin receptacle terminal block, suitable for DIN 35 rail acc. to EN 60715 Accessories End and intermediate plate Push-in type jumper bars, light gray, insulated, IN 14 A Push-in type jumper bars, light gray, insulated, IN 14 A Carrier with 6 coding pins, for coding of female plugs Protective warning marker, with high-voltage symbol, for 5 terminal blocks Test pin, Ø 1 mm/0.039 in WMB Multi marking card, Pin spacing: 3.5 mm/0.138 in, 10 strips with 10 markers per card, white Marker strips, on roll, 50 m, 11 mm/0.039 in wide, white Item no. Pack. unit Item no. Pack. unit Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) 1 mm/0.039 in thick gray 2020-1291 orange 2020-1292 2-way 2000-402 3-way 2000-403 4-way 2000-404 5-way 2000-405 : 10-way 2000-410 100 (4 x 25) 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) from 1 to 3 from 1 to 4 from 1 to 5 : from 1 to 10 2000-433 2000-434 2000-435 : 2000-440 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) orange 1 mm/0.039 in thick gray 2020-1491 orange 2020-1492 2-way 2000-402 3-way 2000-403 4-way 2000-404 5-way 2000-405 : 10-way 2000-410 100 (4 x 25) 100 (4 x 25) 200 (8 x 25) 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) 2000-433 2000-434 2000-435 : 2000-440 200 (8 x 25) 200 (8 x 25) 100 (4 x 25) 100 (4 x 25) from 1 to 3 from 1 to 4 from 1 to 5 : from 1 to 10 2020-100 100 (4 x 25) orange 2020-100 100 (4 x 25) yellow 2000-115 100 (4 x 25) yellow 2000-115 100 (4 x 25) 859-500 859-500 plain 793-35015 plain 793-35015 plain 2009-1101 plain 2009-1101 100 (4 x 25) *Current-carrying capacity curves on request 80 Volume 500 V/6 kV/3 2 IN 13.5 A 3 500 V/6 kV/3 2 IN 13.5 A 3 500 V/6 kV/3 2 IN 13.5 A 3 Terminal block width 3.5 mm / 0.138 in X-COM @-SYSTEM-MINI Terminal block width 3.5 mm / 0.138 in L 9 - 11 mm / 0.39 in 4 L 9 - 11 mm / 0.39 in 4 ® 7 X-COM 1-Conductor/1-Pin Carrier Terminal Blocks MINI -SYSTEMDouble-Deck 2020 Series 48 1-Conductor/1-Pin Double-Deck Carrier Terminal Blocks 1 20.14Series 30.14 - 1 (1.5) mm² 1 AWG 24 - 16 0.14 - 1 (1.5) mm² 2 - 1 (1.5) mm² 1 AWG 24 - 16 1 AWG 24 - 16 1.0 (1.5)mm /AWG 16, 2020 500 V/6 kV/3 2 500 V/6 kV/3 2 500 V/6 kV/3 2 2 1 2 mm2 AWG 24 – 16 500 V/6 kV/3 300 V, 10 A U Terminal block width 3.5 mm / 0.138 in IN 13.5 A* 300 V, 10 A 2 L 9 - 11 mm / 0.39 in 4 Kein Produktbild !! Terminal block width 3.5 mm / 0.137 in L 9 – 11 mm / 0.39 in 3 3(1.5) IN0.14 13.5–A 1 2 Pack. Item No. 3 mm2 AWG 24 – 16 500 V/6 kV/3 300 V, 10 A U Terminal block width 3.5 mm / 0.138 in IN 13.5 A* 300 V, 10 A 2 L 9 - 11 mm / 0.39 in 4 Kein Produktbild !! Terminal block width 3.5 mm / 0.137 in L 9 – 11 mm / 0.39 in Pack. Item No. Unit !! Kein Produktbild 1-conductor/1-pin double-deck carrier terminal Unit !! Kein Produktbild 1-conductor/1-pin double-deck carrier terminal block, through/through terminal block, with marker carrier, housing color: gray 46,9 mm/1.8550 in L/L 2020-2231 80,1 mm/3.15 in N/L 50 2020-2232 L/N 50Pack.-unit 2020-2233 block, through/through terminal block, with marker carrier, housing color: blue 46,9 mm/1.8550 in N 2020-2234 block, ground conductor/through terminal block, with marker carrier, housing color: gray 46,9 mm/1.8550 in 2020-2247 PE/N 80,1 mm/3.15 in PE/L 50 2020-2257 46,9 mm/1.85 in 80,1 mm/3.15 in Kein Produktbild !! 1 Kein Produktbild !! 2 80,1 mm/3.15 in Kein Produktbild !! 2 without marker carrier, housing color gray 50 PE/N 1-conductor/1-pin double-deck carrier terminal 2020-2217 block, ground conductor/through 50 PE/L 2020-2227terminal block, without marker carrier, housing color: gray PE/N 50 2020-2217 PE/L 50 2020-2227 Kein Produktbild !! 3 46,9 mm/1.85 in 80,1 mm/3.15 in Pack.Pack.-unit Unit pcs 2-conductor/2-pin double deck carrier terminal 2-conductor/2-pin double-deck carrier terminal block, 2-conductor/2-pin through terminal block, block, 2-conductor/2-pin through terminal block, marking carrier, internal commoning, withwith marker carrier, internal commoning, conductor entry connector entry colored violet, housing color blue position colored in violet, 46,9 mm/1.85 in 50 N color: blue 2020-2239 housing Item Item No.No. Pack. Pack.-unit pcs 51,3 mm/2.02 in 61,4 mm/2.41 in without marker carrier, housing color blue 50 N 1-conductor/1-pin double-deck carrier terminal 2020-2204 block, through/through terminal block, without marker carrier, housing color: blue N 50 2020-2204 46,9 mm/1.85 in 80,1 mm/3.15 in Pack.-unit Pack. Unit pcs 2-conductor/2-pindouble-deck double deckcarrier carrier terminal 2-conductor/2-pin terminal block,2-conductor/2-pin 2-conductor/2-pinthrough throughterminal terminal block, block, block, with marker marking carrier, internal commoning, with carrier, internal commoning, conductor entry connector entry incolored position colored violet, violet, housing color gray 46,9 mm/1.85 in50 L housing color: gray 2020-2238 ItemNo. No. Item 50 50 51,3 mm/2.02 in 61,4 mm/2.41 in 1 2020-2204 2020-2234 ItemItem No. No. 1-conductor/1-pin double-deck carrierUnit terminal 1-conductor/1-pin double carrier deck carrier terminal 1-conductor/1-pin double-deck terminal block, ground conductor/through terminal block, block, ground conductor/through terminal block, block, ground conductor/through terminal block, without marker carrier, with marker carrier, housing color gray with marker carrier, housing color: gray 50 PE/N 2020-2247 housing color: gray 2020-2217 PE/N 50 2020-2257 50 50 2020-2247 PE/NPE/L PE/L 50 2020-2227 PE/L 50 2020-2257 80,1 mm/3.15 in 51,3 mm/2.02 in 61,4 mm/2.41 in Kein Produktbild !! Pack.-unit Pack. Item No. Item No. pcs 1-conductor/1-pin double-deck carrierUnit terminal 1-conductor/1-pin double deck carrier terminal 1-conductor/1-pin double-deck carrier terminal block, through/through terminal block, block, through/through terminal block, block, through/through terminal block, without marker carrier, with marker carrier, housing color blue with marker carrier, housing color: blue 50 N color: blue 2020-2234 housing 51,3 mm/2.02 in 61,4 mm/2.41 in 51,3 mm/2.02 in 61,4 mm/2.41 in L/N 50 2020-2203 L/N 50 2020-2233 without marker carrier, housing color gray L/L 1-conductor/1-pin double-deck terminal 2020-2201 carrier 50 block, through/through terminal block,50 N/L 2020-2202 without marker carrier, 50 L/N 2020-2203 housing color: gray 2020-2201 L/L 50 N/L 50 2020-2202 L/N 50 2020-2203 80,1 mm/3.15 in N N 3 Pack. Unit !! Kein Produktbild 1-conductor/1-pin double-deck carrier terminal Pack. ItemNo. No. Item pcs 1-conductor/1-pin double-deck carrierUnit terminal 1-conductor/1-pin double deckcarrier carrier terminal 1-conductor/1-pin double-deck terminal block, through/through terminal block, block, through/throughterminal terminalblock, block, block, marker through/through without carrier, with marker carrier, carrier, housing color gray with marker housing color: gray L/L 50 2020-2231 housing color: gray 2020-2201 L/L 50 N/L 2020-2232 L/L 2020-2231 5050 N/L 50 2020-2202 L/N 2020-2233 N/L 5050 2020-2232 3 46,9 mm/1.85 in 80,1 mm/3.15 in 51,3 mm/2.02 in 61,4 mm/2.41 in 46,9 mm/1.85 in 80,1 mm/3.15 in 51,3 mm/2.02 in 61,4 mm/2.41 in Item No. 51,3 mm/2.02 in 61,4 mm/2.41 in IN0.14 13.5–A 13(1.5) 46,9 mm/1.85 in 80,1 mm/3.15 in 51,3 mm/2.02 in 61,4 mm/2.41 in 1 mm2 AWG 24 – 16 500 V/6 kV/3 300 V, 10 A U Terminal block width 3.5 mm / 0.138 in IN 13.5 A 300 V, 10 A 2 L 9 - 11 mm / 0.39 in 4 Kein Produktbild !! Terminal block width 3.5 mm / 0.137 in L 9 – 11 mm / 0.39 in 51,3 mm/2.02 in 61,4 mm/2.41 in IN0.14 13.5–A 13(1.5) 2 51,3 mm/2.02 in 61,4 mm/2.41 in 1 Volume 1 1 51,3 mm/2.02 in 61,4 mm/2.41 in Terminal block®width 3.5 mm / 0.138 in L 9 - 11 mm / 0.39 in 4 Pack.-unit Bestellnr. Pack. Item No. pcs Unit 3 2-conductor/2-pin doublecarrier deck carrier terminal 2-conductor/2-pin double-deck terminal block,block, 2-conductor/2-pin ground conductor terminal block, with marking carrier, internal commoning, 2-conductor/2-pin ground conductor terminal block, housingcarrier, color internal green-yellow with marker commoning, 46,9 mm/1.85 in PE color: green-yellow2020-2237 50 housing Kein Produktbild !! 80,1 mm/3.15 in L 50 N 2020-2239 50 PE 2020-2237 50 2020-2238 without marking carrier, internal commoning, without marking carrier, internal commoning, without marking carrier, internal commoning, Pack. Pack. Pack. 2-conductor/2-pin double-deck carrier terminal 2-conductor/2-pin double-deck terminal 2-conductor/2-pin double-deck conductor entry colored color gray conductor entry colored violet, carrier housing color gray housing color green-yellow Itemviolet, No. housing Item No. Item No. carrier terminal Unit block, Unit block, Unit block, 2-conductor/2-pin through terminal block, 2-conductor/2-pin through terminal block, 50 50 50 L N PE 2020-2208 2020-2209 2020-2207 2-conductor/2-pin carrier terminal 2-conductor/2-pin carrier terminal 2-conductor/2-pin ground double-deck carrier terminal without marker carrier,double-deck internal commoning, conductor without marker carrier,double-deck internal commoning, conductor 2-conductor/2-pin conductor terminal block, block, 2-conductor/2-pin through terminal block, block, 2-conductor/2-pin through terminal block, block, Appropriate systems: WMB/Marking Strips (see pages 96internal -101)commoning, Accessories entry position colored in violet, entry positionmarking colored in violet, without marker carrier, with marker carrier, commoning, conductor entry with marker commoning, conductor entry 2-conductor/2-pin ground conductor terminal block, housing gray internal housing color:carrier, blue internal housing color: green-yellow End andcolor: intermediate plate, 1 mm thick Marking strip, white, plain Double-deck carrier, position coloredmarker in violet, with marker carrier, 2020-2207 internal commoning, 50 Lposition colored in violet, 50 N 2020-2209 50 PE 2020-2208 orange 2020-2292 100 (4 x 25) 11 mm wide pivotable, gray housing color: gray housing color: blue housing color: green-yellow gray 2020-2291 100 (4 x 25) 50 m roll 2009-110 1 2000-121 L 50 N 2020-2239 50 50 (4 x 25) PE 2020-2237 50 2020-2238 Push-in type jumper double-deck bars, light gray,carrier insulated, IN 25 A 2-conductor/2-pin terminal 2-way 2000-402 200 (8block, x 25) block, 2-conductor/2-pin through terminal 2000-403 200 (8 x 25) 3-way without marker carrier, internal commoning, conductor 2000-404 200 (8 x 25) 4-way entry position colored in violet, 2000-405 100 (4 x 25) 5-way housing color: gray L : : 50 2020-2208 10-way 2000-410 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A 2-conductor/2-pin double-deck carrier terminal 1 - 3 2000-433 200block, (8 x 25) block, 2-conductor/2-pin through terminal 2000-434 conductor 200 (8 x 25) 1 - 4commoning, without marker carrier, internal position colored in 1 - 5 2000-435 100 (4 x 25) entry violet, housing color: blue : : N 2020-2209 50100 (4 x 25) 1 - 10 2000-440 WMB Multi marking system, carrier terminal 2-conductor/2-pin double-deck 10 strips with 10 markers per card, block, for conductor 3.5 mm terminal block block, width 2-conductor/2-pin ground terminal marker carrier, internal plain commoning, 793-3501 5 without housing color: green-yellow PE 2020-2207 50 81 X-COM®-SYSTEM MINI 1-Conductor Female Plugs; 2-Conductor Female Plugs 2020 Series 0.14 – 1 (1.5) 500 V/6 kV/3 IN 13.5 A* mm2 AWG 24 – 16 300 V, 10 A U 300 V, 10 A 2 Module width 3.5 mm / 0.138 in L 9 – 11 mm / 0.39 in 0.14 – 1 (1.5) 500 V/6 kV/3 IN 13.5 A* mm2 Module width 3.5 mm / 0.138 in AWG 24 – 16 300 V, 10 A U 300 V, 10 A 2 L 9 – 11 mm / 0.39 in 1 500 V = rated voltage 6 kV = rated surge voltage 3 = pollution degree 2The female plugs come equipped with an end plate, 0.7 mm/0.027 in thick. The receptacle terminal blocks must also be fitted with end plates. Description No. of poles 1-conductor female plug with CAGE CLAMPS, to be inserted into receptacle terminal blocks 1-conductor female plug, with coding fingers, gray, 2 poles 2020-102100 3 poles 2020-103 50 : : 14 poles2020-114 10 15 poles2020-115 10 2-conductor female plug with CAGE CLAMPS, to be inserted into receptacle terminal blocks Item no. Pack. unit Additional poles and/or mixed (gray/blue/greenyellow) female plugs on request Accessories Locking levers can be snapped on female plugs Protective warning marker, with high-voltage symbol, for 5 terminal blocks Strain relief plate, gray, snap-on type, for 1- and 2-conductor female plugs Item no. Pack. unit 2-conductor female plug, with coding fingers, gray, 2 poles 2020-202100 3 poles 2020-203 50 : : 14 poles2020-214 10 15 poles2020-215 10 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Female plugs with 2 poles 3 poles and more gray 2022-141 2022-151 100 (4 x 25) orange 2022-142 2022-152 100 (4 x 25) yellow 2000-115100 (4 x 25) 2 to 3 poles 4 to 6 poles 7 to 9 poles 10 to 15 poles WMB Multi marking card Pin spacing: 3.5 mm/0.138 in, plain 10 strips with 10 markers per card, white Marker strips, on roll, 50 m, plain 11 mm/0.039 in wide, white Test pin, Ø 1 mm/0.039 in 82 No. of poles 734-327 734-328 734-329 734-326 Female plugs with 2 poles 3 poles and more gray 2022-141 2022-151 100 (4 x 25) orange 2022-142 2022-152 100 (4 x 25) yellow 2000-115100 (4 x 25) 2 to 3 poles 4 to 6 poles 7 to 9 poles 10 to 15 poles 734-327 734-328 734-329 734-326 793-35015 plain 793-35015 2009-1101 plain 2009-1101 859-500 859-500 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) X-COM®¥-SYSTEM-MINI @SYSTEM X-COM MINI Female Plugs for Self-Assembly Female Plugs for Self-Assembly 2020Series Series 2020 7 386 12 AWG 24 - 16 1 (1.5) mm¤ 0.14 0.14- – 1 (1.5) mm AWG 24 – 16 500 500V/6 V/6kV/3 kV/32 300 V, 10 A U 13.5AA3 300 V, 10 A 2 ININ13.5 Module block widthwidth 3.5 mm 0.138 in in Terminal 3.5/mm / 0.138 / 0.39 in 4in L L9 -911– mm 11 mm / 0.39 12 AWG 24 - 16 mm¤ 0.14 0.14- 1 – (1.5) 1 (1.5) mm AWG 24 – 16 500 500V/6 V/6kV/3 kV/32 300 V, 10 A U 13.5AA3 300 V, 10 A 2 ININ13.5 Terminal block width 3.5 mm / 0.138 in Module width 3.5 mm / 0.138 in L 9 - 11 mm / 0.39 in 4 L 9 – 11 mm / 0.39 in Self-Assembly of Individual Female Plugs Using modular of female plugs from the X-COM Individual Female Plugs S Self-Assembly Intended SYSTEM, female plugs can be customized for applica® Using modular female plugs from the X-COM¥S-SYSTEM, female plugs can be customized tions requiring varying numbersfor of applications poles (e.g., requiring when varying numbers of poles (e.g., when designing prototydesigning prototypes). pes). According rupting cap live or und Assembly The approp that the ind other witho Modulesand andPole PoleNumbers Numbers Modules A self-assembled of:of: self-assembledfemale femaleplug plugconsists consists Base module withwith endend plateplate • base module and max. 14 end modules. • and max. 14 end modules !7 Intended Use According to EN 61984, connectors without current interrupting capacity shall not be mated and unmated when live or under load. Assembly The appropriate mounting tool shall be used to guarantee that the individual modules are properly Self-Assembly of Individual Female Plugs¥ Intended Use Using modular female plugs from the X-COM S-SYSTEM, According to EN 61984, connectors without current interattached to each other without damaging the locking female plugs can be customized for applications requiring rupting capacity shall not be mated and unmated when latches. varying numbers of poles (e.g., when designing prototylive or under load. 387 pes). Ǔ Ǔ Ǔ Modules and Pole Numbers Pack. A self-assembled female plug consists of: Item Base module withNo. end plateUnit and max. 14 end modules. 1-conductor end module, with coding fingers gray 2020-181 250 blue 2020-184 250 green-yellow 2020-187 250 Ǔ Ǔ Ǔ Ǔ Ǔ Ǔ Assembly The appropriate mounting tool shall be used to guarantee Pack. that the individual modules are properly attached to each No. the locking latches. other withoutItem damaging Unit 2-conductor end module, with coding fingers gray 2020-281 blue 2020-284 green-yellow 2020-287 250 250 250 1 Conductor sizes: 0.14 mm¤ o 1.5 mm¤ is + f-stw; Push-in conductor sizes: 0.5 mm¤ o 1.5 mm¤ isw and 0.5 mm¤ o 0.75 mm¤ iinsulated ferrule, 10 mmw 1-conductor base module with end plate, with coding fingers gray 2020-161 250 blue 2020-164 250 green-yellow 2020-167 250 Ǔ Ǔ Ǔ 2-conductor base module with end plate, with coding fingers gray 2020-261 250 blue 2020-264 250 green-yellow 2020-267 250 2 500 V = rated voltage 6 kV = rated surge voltage 3 = pollution degree Self-Assembly of Individual Female Plugs Intended Use Using modular female plugs from the X-COM S-SYSTEM, According to EN 61984, connectors without current interSection 14)requiring rupting female plugs can(see be customized for applications capacity shall not be mated and unmated when varying End numbers Module of poles (e.g., when designing prototylive or under load. pes). Assembly curves upon request 3 Current-carrying capacity ¥ Modules and Pole Numbers A self-assembled female plug consists of: Base module with end plate and max. 14 end modules. ! The appropriate mounting tool shall be used to guarantee that the individual modules are properly attached to each other withoutor damaging the locking latches. instructions. 4 Strip length, see packaging 1 Conductor sizes: 0.14 mm¤ o Push-in conductor sizes: 0.5 m and 0.5 mm¤ o 0.75 mm¤ iinsulated ferrule, 10 mmw Accessories Female Plugs Accessories Appropriate marking systems: WMB/Marking strips Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) (see Section 13) Protective warning marker, with high-voltage symbol, black, for 5 terminal blocks yellow 2000-115 100 (4x25) Locking lever, 9.6 mm wide 2022-152 100 (4x25) Endorange Module gray 2022-151 100 (4x25) Locking lever, 4.8 mm wide 2022-142 100 (4x25) orange gray 2022-141 100 (4x25) Strain relief plate, gray 35 mm width 734-326 100 (4x25) 6 mm wide 734-327 100 (4x25) 12.5 mm width 734-328 100 (4x25) 25 mm wide 734-329 5-Pole, 100 (4x25) Example: 1-Conductor 2 500 V = rated voltage 6 kV = rated surge voltage 3 = pollution degree (see Section 14) 3 Current-carrying capacity curv 4 Strip length, see packaging o Example: 5-Pole, 1-Conductor Fe End Module Base Module Base Module Example: 5-Pole, 1-Conductor Female Plug Female Plug Base module with end plate 2020-167 WMB Multi marking system, 10 strips with 10 markers per card, for 3.5 mm terminal block width plain 793-3501 Marking strip, plain, 11 mm wide, 50 m roll white 2009-110 End module 2020-184 5 1 End modules 2020-181 83 7 ® X-COM -SYSTEM ¥ X-COM @-SYSTEM-MINI Pre-Assembled Female 7 Pre-Assembled FemalePlugs Plugs 2020 Series Series 388 2020 0.14 - 1 (1.5) mm¤ 1 AWG 24 - 16 2 0.14 – 1 (1.5) mm 500 kV/3 V/6 kV/3 2 500 V/6 IN A 13.5 A 3 IN 13.5 0.14 - 1 L 9 - 11 mm / 0.39 in 4 L 9 – 11 mm / 0.39 in L 9 - 11 mm / 0.39 in 4 Ǔ Item No. Pole 1 Pole 1 Pack. Unit Pole No. 2-conductor female plug with ground base module (green-yellow), for insertion into carrier terminal blocks, with coding fingers 3 2020-203/000-036 50 Ǔ Ǔ Item No. 2-conductor female plug with ground end module (green-yellow), for insertion into carrier terminal blocks, with coding fingers 3 2020-203/000-037 50 Ǔ Protective warning marker, with high-voltage symbol, black, for 5 terminal blocks yellow 2000-115 100 Locking lever, 9.6 mm wide 2022-152 100 orange gray 2022-151 100 Locking lever, 4.8 mm wide 2022-142 100 orange gray 2022-141 100 Strain relief plate, gray 35 mm width 734-326 100 6 mm wide 734-327 100 12.5 mm width 734-328 100 25 mm wide 734-329 100 L 9 – 11 mm / 0.39 in Pole 1 Pack. Unit Pole No. Ǔ Item No. Pole 1 Pack. Unit 2-conductor female plug with ground base module (green-yellow), for insertion into carrier terminal blocks, with coding fingers 5 2020-205/000-036 50 2-conductor female plug with ground end module (green-yellow), for insertion into carrier terminal blocks, with coding fingers, green-yellow, blue, gray 3 2020-203/000-039 50 Ǔ 2-conductor female plug with ground end module (green-yellow), for insertion into carrier terminal blocks, with coding fingers 5 2020-205/000-037 50 For other lengths up to maximum 15 poles, please contact factory. Accessories Female Plugs Accessories N Pole 1 2-conductor female plug with ground base module (green-yellow), for insertion into carrier terminal blocks, with coding fingers, gray, blue, green-yellow 3 2020-203/000-038 50 For other lengths up to maximum 15 poles, please contact factory. 0.14 - 1 (1.5) mm¤ 1 AWG - 16 0.14 – 1 (1.5) mm2 24AWG 24 – 16 2 500500 V/6 V/6 kV/3kV/3 300 V, 10 A U 3 IN 13.5 A I 13.5 A module widthwidth 3.5 mm 3.5 / 0.138 mmin/ 0.138 in Module L 9 - 11 mm / 0.39 in 4 For other lengths up to maximum 15 poles, please contact factory. Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Appropriate marking systems: WMB/Marking strips (see Section 13) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) WMB Multi marking system, 10 strips with 10 markers per card, for 3.5 mm terminal block width plain 793-3501 Marking strip, plain, 11 mm wide, 50 m roll white 2009-110 5 1 For list of approvals and user guide, see pages 634 to 637. 84 module width width 3.5 in in Module 3.5mm mm/ 0.138 / 0.138 Pole 1 Pole No. AWG 24 – 16 300 V, 10 A U module width / 0.138in in Module width 3.5 3.5 mmmm / 0.138 L 9 – 11 mm / 0.39 in (1.5) mm¤ 1 AWG 24 - 16 0.14 – 1 (1.5)2mm2 500V/6 V/6 kV/3 kV/3 500 13.5A A 3 ININ13.5 AWG 24 – 16 300 V, 10 A U !7 X-COM®-SYSTEM Pre-Assembled Female Plugs 2020 Series mm¤mm 0.14 0.14- 1 – (1.5) 1 (1.5) 2 500 500V/6 V/6kV/3 kV/3 IINN13.5 13.5AA3 2 1 AWG 24 - 16 AWG 24 – 16 300 V, 10 A U 389 module 3.5 mm 0.138 in 3.5/mm / 0.138 in Modulewidth width L 9 - 11 mm / 0.39 in 4 L 9 – 11 mm / 0.39 in Pole 1 Pole 1 1 Conductor sizes: 0.14 mm¤ o 1.5 mm¤ is + f-stw; Push-in conductor sizes: 0.5 mm¤ o 1.5 mm¤ isw and 0.5 mm¤ o 0.75 mm¤ iinsulated ferrule, 10 mmw 2 500 V = rated voltage 6 kV = rated surge voltage 3 = pollution degree (see Section 14) 3 Current-carrying capacity curves upon request 4 Strip length, see packaging or instructions. Pole No. Ǔ Item No. Pack. Unit 2-conductor female plug with ground base module (green-yellow), for insertion into carrier terminal blocks, with coding fingers, gray, blue, green-yellow 5 2020-205/000-038 50 Ǔ 2-conductor female plug with ground end module (green-yellow), for insertion into carrier terminal blocks, with coding fingers, green-yellow, blue, gray 5 2020-205/000-039 50 7 For other lengths up to maximum 15 poles, please contact factory. 85 X-COM -SYSTEM -SYSTEM X-COM¥@ Carrier Terminal Block 7 1-Conductor/1-Pin 1-Conductor/1-Pin Carrier Terminal Blocks 2 (4)mm 2022 Series/AWG 12, 2022 Series 394 2.5 ® 12 AWG 22 - 12 mm¤ 0.25 -–2.5 0.25 2.5(4)(4) mm AWG 22 – 12 690 V/6 V/6 kV/3 690 kV/32 600 V, 20 A U 24 A IINN 24 A (32 (32A) A)3 600 V, 20 A 2 1 2AWG (4) (4) mm¤mm 0.25 22 - 12 0.25- 2.5 – 2.5 AWG 22 – 12 Terminal block 5.2 mmmm / 0.205 in in Terminal blockwidth width 5.2 / 0.205 L 10 – 12 mm / 0.43 in ¥ L 10 - 12 mm / 0.43 in 4 Terminalblock block width / 0.205 in Terminal width 5.25.2 mm mm / 0.205 in 4 10 12 mm / 0.43 in L L 10 – 12 mm / 0.43 in X-COM @-SYSTEM 1-Conductor/1-Pin Carrier Terminal Blocks 2022 Series 394 32,5 mm/ 1.28 in 0.25 - 2.5 (4) mm¤ 1 AWG 22 - 12 690 V/6 kV/3 2 IN 24 A (32 A) 3 0.25 - 2.5 Terminal block width 5.2 mm / 0.205 in L 10 - 12 mm / 0.43 in 4 28,6 mm/1.13 in 48,5 mm/1.91 in Item No. (4) mm¤ 1 AWG 22 - 12 Terminal block width 5.2 mm / 0.205 in L 10 - 12 mm / 0.43 in 4 28,6 mm/1.13 in 50,8 mm/2 in Pack. Unit Item No. ! 1 Conductor sizes: 0.25 mm¤ o 4 mm¤ is + f-stw; Push-in conductor sizes: 0.75 mm¤ o 4 mm¤ isw and 0.75 mm¤ o 2.5 mm¤ iinsulated ferrule, 12 mmw 32,5 mm/ 1.28 in 7 ! Pack. Unit 2 690 V = rated voltage 6 kV = rated surge voltage 3 = pollution degree (also see Section 14) 3 See "Current-carrying capacity curves upon request" see packaging or instructions. 4 Strip length, Insert coding pin into the corresponding slot and twist it off. notes for: 5 See application Colored push-in type jumper bars, page 139 Staggered jumper, page 141 Push-in typesizes: wire 0.25 jumper, page mm¤ o 4140 mm¤ is + f-stw; 1 Conductor Push-in conductor sizes: 0.75 mm¤ o 4 mm¤ isw and 0.75 mm¤ o 2.5 mm¤ Accessories iinsulated ferrule, 12 mmw 2 690 V = rated voltage 6 kV = rated surge voltage 3 = pollution degree WMB marking (alsoMulti see Section 14)system, 10 strips with 10 markers per card, 3 See "Current-carrying capacity curves upon request" stretchable 5 - 5.2 mm Item-Specific Accessories 4 Strip length, see packaging or instructions. plain 793-5501 5 See Multi application notessystem, for: 5 Protective warning marker, WMB marking plain, Colored push-in type jumper bars, page 139 with symbol, black, 10 strips with 10 markers per card, 28,6high-voltage mm/1.13 in 28,6 mm/1.13 in Staggered page Carrierjumper, terminal blocks and141 female plugs are protected 48,5 mm/1.91 50,8 mm/2 in for 5 terminal blocksin stretchable 5 - 5.2140 mm contact. page Push-inagainst type accidental wire jumper, yellow 2002-115 100 (4x25) yellow 793-5501/000-002 Pack. Pack. 793-5501/000-005 Accessoriesred 2022 Series Accessories Item No. Item No. Unit Unit blue 793-5501/000-006 WMB/WMB Inline/Marking strips Accessories Appropriate marking systems: WMB/Marking Strips (seegray pages 96 793-5501/000-007 -101) 1-conductor/1-pin carrier terminal block, 1-conductor/1-pin ground carrier terminal block, (see Section 13) for DIN 35 rail, acc. to EN 60715 for DIN 35 rail, acc. to EN 60715 orange 793-5501/000-012 Slim style jumper WMB Multi marking system, 793-5501/000-017 100 green-yellow 100 light green Endgray and intermediate2022-1201 plate, 1 mm thick Staggered jumper, 2022-1207 10 strips with 10793-5501/000-023 markers per card, blue 100 100 (4x25) 5 green orange2022-1204 2022-1292 insulated, stretchable 5 - 5.2 mm violet 793-5501/000-024 IN 25 A, 2022-1291 100 (4x25) Item-Specificgray Accessories plain 793-5501 55 light gray Protective marker, Insulation warning stop, WMB Multi Inline,marking plain, system, plain, 2-way 2002-472 100 (4x25) WMB with high-voltage symbol, black, 10 strips with 5 pcs/strip, stretchable 5 10 - 5.2markers mm, per card, 3-way 2002-473 100 (4x25) for 5 terminal blocks stretchable 5 -markers, 5.2 mm 5 mm, on roll 4-way 2002-474 100 (4x25) 0.25 - 0.5 mm¤ 1,500 WMB yellow 2002-115 100 (8x25) (4x25) yellow 793-5501/000-002 5-way 2002-475 50 (2x25) light gray 2002-171 200 white 2009-115 1 red 793-5501/000-005 6-way 2002-476 50 (2x25) Marking strip, plain, Insulation stop, Accessories 2022 Series blue 7-way 2002-477 50 (2x25) 5 pcs/strip, 11 mm wide, 793-5501/000-006 WMB/WMB Inline/Marking strips gray 793-5501/000-007 8-way 2002-478 50 (2x25) 0.75 - 1 mm¤ 50 m roll (see Section 13) orange 793-5501/000-012 9-way 2002-479 50 (2x25) dark gray 2002-172 200 (8x25) white 2009-110 1 793-5501/000-017 10-way 2002-480 50 (2x25) Screwless end light End andtype intermediate plate, 1 mm thick Staggered jumper, Push-in jumper bar, insulated, stop,green 5 green 11-way 2002-481 50 (2x25) orange 2022-1292 100 (4x25) 5 insulated, IN 25 A, for DIN 35 rail,793-5501/000-023 violet 793-5501/000-024 2002-482 50 (2x25) I12-way gray 2022-1291 100 (4x25) light gray 6 mm wide N 25 A, 5 light gray 2-way 2002-402 200 (8x25) gray 249-116 100 (4x25) Insulation stop, 3-way 2-way 2002-472 100 (4x25) WMB Inline, plain, 2002-403 200 (8x25) Push-in type wire jumper, 54-way pcs/strip, stretchable 5 - 5.2 mm, 3-way 2002-473 100 (4x25) 2002-404 200 (8x25) 5 insulated, 4-way 2002-474 100 (4x25) 0.25 1,500 WMB markers, 5 mm, on roll 5-way- 0.5 mm¤ 2002-405 100 (4x25) IN 16 A, 5-way 2002-475 50 (2x25) light gray 2002-171 white 2009-115 1 6-way 2002-406 200 100 (8x25) (4x25) wire size 1.5 mm¤ 6-way 2002-476 50(10x10) (2x25) Marking strip, plain, Insulation stop, 7-way 2002-407 100 (4x25) L = 60 mm 2009-412 100 7-way 50(10x10) (2x25) 2002-408 100 (4x25) 58-way pcs/strip, 11 mm wide, L = 110 mm 2002-477 2009-414 100 8-way 50(10x10) (2x25) 9-way- 1 mm¤ 2002-409 100 (4x25) 0.75 50 m roll L = 250 mm 2002-478 2009-416 100 9-way 2002-479 50 (2x25) 10-way 2002-410 200 100 (8x25) (4x25) dark gray 2002-172 white 2009-110 1 10-way pins, 2002-480 50 (2x25) Screwless end stop, Push-in Push-in type type jumper jumper bar, bar, insulated, insulated, Carrier with 6 coding 5 11-way 2002-481 50 (2x25) IINN 25 for DIN 35 rail, 25 A, A, for coding female plugs 12-way 2002-482 50 (2x25) light 6 mm wide light gray gray orange 2022-100 100 (4x25) 2-way 2002-402 gray 249-116 100 (4x25) from 1 to 3 2002-433 200 200 (8x25) (8x25) 3-way 2002-403 from 1 to 4 2002-434 200 200 (8x25) (8x25) Push-in Test pin,type wire jumper, 4-way 2002-404 insulated, from 1 to 5 2002-435 200 100 (8x25) (4x25) 5 1 mm 5-way 2002-405 IN 16 A, from 1 to 6 2002-436 100 100 (4x25) (4x25) 859-500 1 6-way 2002-406 wire size 1.5 mm¤ from 1 to 7 2002-437 100 100 (4x25) (4x25) 7-way 2002-407 L = 60plug mm 2009-412 100 (10x10) from 1 to 8 2002-438 100 100 (4x25) (4x25) 1-conductor female 8-way 2002-408 Lgray = 110 mm 2009-414 from 1 to 9 2002-439 100 100 (4x25) (4x25) 2022-101 100 (10x10) 200 9-way L = 250 mm 2009-416 100 (10x10) from 1 to 10 2002-409 2002-440 100 100 (4x25) (4x25) 10-way 2002-410 100 (4x25) Push-in jumper bar, For list oftype approvals and userinsulated, guide, see pages 634 to 637. Carrier with 6 coding pins, IN 25 A, for coding female plugs 86 light gray orange 2022-100 100 (4x25) from 1 to 3 2002-433 200 (8x25) Ǔ 1-conductor/1-pin ground carrier terminal block, for DIN 35 rail, acc. to EN 60715 green-yellow 2022-1207 100 32,5 mm/ 1.28 in Ǔ 32,5 mm/ 1.28 in Ǔ 1-conductor/1-pin carrier terminal block, for DIN 35 rail, acc. to EN 60715 gray 2022-1201 100 blue 2022-1204 100 Ǔ Ǔ Ǔ X-COM®-SYSTEM 2-Conductor/1-Pin-Receptacle and 2-Conductor/2-Pin-Receptacle Terminal Block 2.5 (4)mm2/AWG 12, 2022 Series AWG 22 - 12 600 V, 20 A U 600 V, 20 A 2 AWG 22 - 12 600 V, 20 A U 600 V, 20 A 2 Terminal block width 5.2 mm / 0.205 in L 10 - 12 mm / 0.43 in 32,5 mm/ 1.28 in Terminal block width 5.2 mm / 0.205 in L 10 - 12 mm / 0.43 in 0.25 - 2.5 (4) mm² 690 V/6 kV/3 IN 24 A (28 A) 39,2 mm/1.55 in 59,2 mm/2.33 in Item No. 2-Conductor/1-Pin-Receptacle, suitable for DIN 35 rail gray 2022-1301 blue 2022-1304 32,5 mm/ 1.28 in 0.25 - 2.5 (4) mm² 690 V/6 kV/3 IN 24 A (32 A) 46,6 mm/1.83 in 86,2 mm/3.39 in Pack.-unit pcs 100 100 2-Conductor/1-Pin-Ground-Receptacle, suitable for DIN 35 rail 100 green-yellow 2022-1307 Item No. 2-Conductor/2-Pin-Receptacle, suitable for DIN 35 rail gray 2022-1401 blue 2022-1404 Pack.-unit pcs 50 50 2-Conductor/2-Pin-Ground-Receptacle, suitable for DIN 35 rail 50 green-yellow 2022-1407 Accessories - Item Specific End and intermediate plate, 1 mm thick orange 2022-1392 gray 2022-1391 Accessories 100 (4x25) 100 (4x25) End and intermediate plate, 1 mm thick orange 2022-1492 gray 2022-1491 100 (4x25) 100 (4x25) Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Push-in type wire jumpers, isolated, Continuous marking strip, blank IN 16 A, 11 mm wide, wire size 1.5 mm² 0.25 - 0.5 mm² 50 m roll 60 mm 2009-412 100 (10x10) light gray 2002-171 200 (8x25) white 2009-110 110 mm 2009-414 100 (10x10) WMB Inline, blank, 0.75 - 1 mm² dark gray 2002-172 200 (8x25) 5 - 5.2 mm 250 mm 2009-416 100 (10x10) 1,500 WMB-markers on 5 mm roll Carrier wiht 6 coding pins Push-in type jumper bars, light gray, insulated white 1 2009-115 for coding of female plugs IN 25 A, 2-way 2002-402 200 (8x25) orange 2022-100 100 (4x25) 3-way 2002-403 200 (8x25) Slim Style Jumpers, light gray, insulated, IN 25 A 4-way 2002-404 200 (8x25) Test pin, 2-way 2002-472 100 (4 x 25) : 1 mm Ø 3-way 2002-473 100 (4 x 25) 10-fach 2002-410 100 (4x25) 1 4-way 859-500 2002-474 100 (4 x 25) Push-in type jumper bars, light gray, insulated Protective warning marker, with high voltage symbol 5-way 2002-475 50 (2 x 25) IN 25 A, for 5 mm terminal blocks 5-way 2002-476 50 (2 x 25) yellow 2002-115 100 (4x25) 5-way 2002-477 50 (2 x 25) 1-3 2002-433 200 (8x25) 5-way 2002-478 50 (2 x 25) 1-4 2002-434 200 (8x25) 1-conductor female plug 5-way 2002-479 50 (2 x 25) 1-5 2002-435 100 (4x25) gray 200 5-way 2022-101 2002-480 50 (2 x 25) : 5-way 2002-481 50 (2 x 25) 1 - 10 2002-440 100 (4x25) 12-way 2002-482 50 (2 x 25) WMB multi marking card 10 strips with 10 markers each 5 - 5.2 mm blank 5 793-5501 Insulation stop, 5 pcs / Strip, 87 X-COM®-SYSTEM 1-Conductor/1-Pin Double Deck Receptacle Terminal Blocks 2.5 (4)mm2/AWG 12, 2022 Series AWG 22 - 12 600 V, 20 A U 600 V, 20 A 2 Terminal block width 5.2 mm / 0.205 in L 10 - 12 mm / 0.43 in 51,3 mm/2.02 in 61,4 mm/2.41 in Terminal block width 5.2 mm / 0.205 in L 10 - 12 mm / 0.43 in 0.25 - 2.5 (4) mm² 690 V/6 kV/3 IN 24 A (28 A) 46,9 mm/1.85 in 80,1 mm/3.15 in Item No. 46,9 mm/1.85 in 80,1 mm/3.15 in Pack.-unit pcs AWG 22 - 12 600 V, 20 A 2 Terminal block width 5.2 mm / 0.205 in L 10 - 12 mm / 0.43 in Item No. 46,9 mm/1.85 in 80,1 mm/3.15 in Pack.-unit pcs Item No. Pack.-unit pcs without marker carrier, housing color gray 50 L/L 2022-2201 50 N/L 2022-2202 50 L/N 2022-2203 without marker carrier, housing color blue 50 N/N 2022-2204 without marker carrier, housing color gray 50 PE/N 2022-2217 50 PE/L 2022-2227 Item No. Pack.-unit pcs 46,9 mm/1.85 in 80,1 mm/3.15 in Item No. Pack.-unit pcs 51,3 mm/2.02 in 61,4 mm/2.41 in 1-conductor/1-pin double deck receptacle, ground/through with marker carrier, housing color gray 50 PE/N 2022-2247 50 PE/L 2022-2257 51,3 mm/2.02 in 61,4 mm/2.41 in 1-conductor/1-pin double deck receptacle, through/through with marker carrier, housing color blue 50 N/N 2022-2234 51,3 mm/2.02 in 61,4 mm/2.41 in 1-conductor/1-pin double deck receptacle, through/through with marker carrier, housing color gray L/L 50 2022-2231 50 N/L 2022-2232 50 L/N 2022-2233 46,9 mm/1.85 in 80,1 mm/3.15 in 46,9 mm/1.85 in 80,1 mm/3.15 in Bestellnr. Pack.-unit pcs 2-conductor/2-pin double deck receptacle feed through with marking carrier, internal common connector entry colored violet, housing color gray L 50 2022-2238 2-conductor/2-pin double deck receptacle feed through with marking carrier, internal common connector entry colored violet, housing color blue N 50 2022-2239 2-conductor/2-pin double deck receptacle ground with marking carrier, internal common housing color green-yellow PE 50 2022-2237 without marking carrier, housing color gray 50 L 2022-2208 without marking carrier, housing color blue 50 N 2022-2209 with marking carrier, housing color green-yellow 50 PE 2022-2207 Accessories 88 0.25 - 2.5 (4) mm² 690 V/6 kV/3 IN 24 A (28 A) 51,3 mm/2.02 in 61,4 mm/2.41 in AWG 22 - 12 600 V, 20 A U 600 V, 20 A 2 51,3 mm/2.02 in 61,4 mm/2.41 in 0.25 - 2.5 (4) mm² 690 V/6 kV/3 IN 24 A (28 A) Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) End and intermediate plate, 1 mm thick orange 2022-2292 100 (4 x 25) gray 2022-2291 100 (4 x 25) Double-deck marker carrier, pivotable, gray 2002-121 Push-in type jumper bars, light gray, insulated, IN 25 A 2-way 2002-402 200 (8 x 25) 3-way 2002-403 200 (8 x 25) 4-way 2002-404 200 (8 x 25) 5-way 2002-405 100 (4 x 25) : : 10-way 2002-410 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A 1 - 3 2002-433 200 (8 x 25) 1 - 4 2002-434 200 (8 x 25) 1 - 5 2002-435 100 (4 x 25) : : 1 - 10 2002-440 100 (4 x 25) 50 (4 x 25) Marking strip, white, plain 11 mm wide 50 m roll 2009-110 1 WMB Multi marking system, 10 strips with 10 markers per card, for 3.5 mm terminal block width plain 793-5501 5 X-COM®-SYSTEM 1-Conductor Female Plugs 2022 Series 0,25 — 2.5 (4) 690 V/6 kV/3 IN 24 (32) A* mm2 AWG 22 — 12 600 V, 20 A U 600 V, 20 A 2 Module width 5.2 mm / 0.205 in L 10 — 12 mm / 0.43 in Description No. of poles 1-conductor female plug with CAGE CLAMPS connection, to be fixed on receptacle terminal blocks or male connectors 1-conductor female plugs, with coding fingers, gray, 1 pole 2022-101 200 2 poles 2022-102 100 3 poles 2022-103 50 : : 14 poles2022-114 10 15 poles2022-115 10 Higher number of poles and/or mixed (gray/blue/green-yellow) female plugs on request Item no. Pack. unit For other lengths, please contact factory Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Accessories Insulation stop ➋, 5 pieces/strip light gray dark gray Locking levers, can be snapped on female plugs gray orange Protective warning marker, yellow with high-voltage symbol, for 5 terminal blocks Strain relief plate, gray snap-on type, for 1-conductor female plugs Test pin, 1 mm/0.039 in Ø 0.25 — 0.5 mm2 0.75 — 1 mm2 2002-171 2002-172 200 strips 200 strips Female plugs with 1 pole 2 poles and more 2022-141 2022-151 100 (4 x 25) 2022-142 2022-152 100 (4 x 25) 2002-115 100 (4 x 25) 2-pole 3- to 4-pole 5- to 6-pole 7- to 10-pole 11- to 14-pole 15-pole 734-327 734-328 734-329 734-326 734-430 734-431 859-500 To code a female plug, remove the desired coding finger using a suitable tool . . . 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 100 (4 x 25) 50 (2 x 25) 50 (2 x 25) *Current-carrying capacity curves on request . . . and insert a 2022-100 coding pin into the corresponding location of the receptacle terminal block. 89 X-COM¥@-SYSTEM ® X-COM SYSTEM Female Plugs for Self-Assembly Female Plugs for Self-Assembly, 2022 Series 402 7 0.25 - 2.5 (4) mm¤21 AWG 22 - 12 0.25 – 2.5 (4) mm AWG 22 – 12 690 V/6 690 V/6 kV/3 kV/32 600 V, 20 A u (32A A) 3 IINN 24 A(32) 600 V, 20 A 2 Terminal block mm / 0.205 in in Terminal blockwidth width5.2 5.2 mm / 0.205 L 10 – 12 mm / 0.43 in L 10 - 12 mm / 0.43 in 4 Item No. Ǔ Ǔ Ǔ 1-conductor end module, with coding fingers gray 2022-181 blue 2022-184 green-yellow 2022-187 2022 Series Self-Assembly of Individual Female Plugs Using modular female plugs from the X-COM®SSYSTEM, female plugs can be customized for applications requiring varying numbers of poles (e.g., when designing prototypes). Modules and Pole Numbers A self-assembled female plug consists of: • base module with end plate • and max. 14 end modules Pack. Unit Intended Use According to EN 61984, connectors without current interrupting capacity shall not be mated and unmated when live or under load. Assembly The appropriate mounting tool shall be used to guarantee that the individual modules are properly attached to each other without damaging the locking latches. 250 250 250 End Module Ǔ Ǔ Ǔ 1-conductor center module, with coding fingers gray 2022-171 blue 2022-174 green-yellow 2022-177 250 250 250 Ǔ Ǔ Ǔ 1-conductor base module, with integrated end plate, with coding fingers gray 2022-161 250 blue 2022-164 250 green-yellow 2022-167 250 Center Module Accessories Female Plugs Accessories Appropriate marking systems: WMB/Marking strips/WMB Inline Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) (see Section 13) Insulation stop, 5 pcs/strip, 0.25 - 0.5 mm¤ light gray 2002-171 200 Insulation stop, 5 pcs/strip, 0.75 - 1 mm¤ dark gray 2002-172 200 Locking lever, 4.8 mm wide orange 2022-142 100 gray 2022-141 100 Locking lever, 9.6 mm wide orange 2022-152 100 gray 2022-151 100 Protective warning marker, with high-voltage symbol, black, for 5 terminal blocks yellow 2002-115 100 Strain relief plate, gray 35 mm width 734-326 100 6 mm wide 734-327 100 12.5 mm width 734-328 100 25 mm wide 734-329 100 55 mm width 734-430 50 75 mm width 734-431 50 (8x25) (8x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (4x25) (2x25) (2x25) For list of approvals and user guide, see pages 634 to 637. 90 WMB Multi marking system, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm plain 793-5501 WMB Multi marking system, plain, 10 strips with 10 markers per card, stretchable 5 - 5.2 mm yellow 793-5501/000-002 red 793-5501/000-005 blue 793-5501/000-006 gray 793-5501/000-007 orange 793-5501/000-012 light green 793-5501/000-017 green 793-5501/000-023 violet 793-5501/000-024 5 Base Module Example: 5-Pole, 1-Conductor Female Plug 5 WMB Inline, plain, stretchable 5 - 5.2 mm, 1,500 WMB markers, 5 mm, on roll white 2009-115 Marking strip, plain, 11 mm wide, 50 m roll white 2009-110 1 Base module with integrated end plate 2022-167 1 Center module 2022-174 Center modules 2022-171 End module 2022-181 X-COM®-SYSTEM Pre-Assembled Female Plugs, 2022 Series 0.25 – 2.5 (4) mm2 690 V/6 kV/3 ➊ IN 24 (32) A* AWG 22 – 12 600 V, 20 A U Module width 5.2 mm / 0.205 in Item no. AWG 22 – 12 600 V, 20 A U Pack. unit No. of poles Item no. Pack. unit 1-conductor female plug, with coding fingers, gray, green-yellow 1-conductor female plug, with coding fingers, gray, blue, green-yellow, 2022-103/000-037 50 Accessories 200 (8x25) 200 (8x25) Locking lever, 4.8 mm wide orange 2022-142 100 (4x25) gray 2022-141 100 (4x25) Locking lever, 9.6 mm wide orange 2022-152 100 (4x25) gray 2022-151 100 (4x25) Protective warning marker, with high voltage symbol for 5 mm terminal blocks yellow 2002-115 100 (4x25) Strain relief plate, gray 3.5 mm wide 6 mm wide 12.5 mm wide 25 mm wide 55 mm wide 75 mm wide 734-326 734-327 734-328 734-329 734-430 734-431 2022-103/000-039 No. of poles Item no. Pack. unit 1-conductor female plug, with coding fingers, green-yellow, blue, gray, 50 5 poles 2022-105/000-038 50 1-conductor female plug, with coding fingers, gray, blue, green-yellow, 50 5 poles 2022-105/000-039 50 Appropriate marking systems: WMB/Marking Strips (see pages 96 -101) Insulation stop, 5 pcs / Strip, 0.25 - 0.5 mm² light gray 2002-171 0.75 - 1 mm² dark gray 2002-172 3 poles 2022-103/000-038 AWG 22 – 12 600 V, 20 A U L 10 – 12 mm / 0.43 in 1-conductor female plug, with coding fingers, green-yellow, blue, gray, 3 poles 0.25 – 2.5 (4) mm2 690 V/6 kV/3 ➊ IN 24 (32) A* Module width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in 1-conductor female plug, with coding fingers, green-yellow, gray, 3 poles 2022-103/000-036 50 3 poles mm2 Module width 5.2 mm / 0.205 in L 10 – 12 mm / 0.43 in No. of poles 0.25 – 2.5 (4) 690 V/6 kV/3 IN 24 (32) A* WMB Multi marking card 10 strips with 10 markers each 5 - 5.2 mm blank 793-5501 WMB Inline, blank, 5 - 5.2 mm 1,500 WMB-markers on 5 mm roll white 2009-115 Continuous marking strip, blank 11 mm wide, 50 m roll white 5 1 100 (4x25) 100 (4x25) 100 (4x25) 100 (4x25) 50 (2x25) 50 (2x25) 91 ? Separator Plates, Oversized Separator plates, oversized suitable for 2002 Series Terminal Blocks Separator plates, oversized suitable for 2004 Series Terminal Blocks Separator plates, oversized suitable for 2006 Series Terminal Blocks Item no. Pack-unit pcs. Item no. Pack-unit pcs. Item no. Pack-unit pcs. Separator plate, oversized, 0.8 mm/ 0.031 in thick suitable for 2-conductor terminal blocks orange 2002-1294 100 gray 2002-1293 100 Separator plate, oversized, 0.8 mm/ 0.031 in thick suitable for 2-conductor terminal blocks orange 2004-1294 100 gray 2004-1293 100 Separator plate, oversized, 0.8 mm/ 0.031 in thick suitable for 2-conductor terminal blocks orange 2006-1294 100 gray 2006-1293 100 Item no. Pack-unit pcs. Separator plate, oversized, 0.8 mm/ 0.031 in thick suitable for 3-conductor terminal blocks orange 2002-1394 100 gray 2002-1393 100 Item no. Pack-unit pcs. Separator plate, oversized, 0.8 mm/ 0.031 in thick suitable for 3-conductor terminal blocks orange 2004-1394 100 gray 2004-1393 100 Item no. Pack-unit pcs. Separator plate, oversized, 0.8 mm/ 0.031 in thick suitable for 3-conductor terminal blocks orange 2006-1394 100 gray 2006-1393 100 Note: Exe/Exi separators can be used with all TOPJOB®S series Item no. Pack-unit pcs. Separator plate, oversized, 0.8 mm/ 0.031 in thick suitable for 4-conductor terminal blocks orange 2002-1494 100 gray 2002-1493 100 92 Item no. Pack-unit pcs. Separator plate, oversized, 0.8 mm/ 0.031 in thick suitable for 4-conductor terminal blocks orange 2004-1494 100 gray 2004-1493 100 Item no. Pack-unit pcs. Exe/Exi, separator, 3 mm/ .117 in thick orange 90 mm wide 209-190 100 120 mm wide 209-191 100 125.5 mm wide 209-192* 50 *(shown above) Mounting Accessories Carrier Rails and Stickers for Operating Instructions Rail end cap Adjustable height group marker carriers <__ 28‑mm / __> 1.10 in End stop Screwdrivers with partially insulated shaft for optimum handling in terminal blocks <__ 45‑mm /1.77‑in __> ItemPack.-unit No.pcs Rail end cap, for DIN 35 rail (7.5 mm high) 209-109 50 (2 x 25) ItemPack.-unit No.pcs Adjustable height group marker carriers, 249-119 50 (2 x 25) Marker card . . ., from white cardboard, for self-marking, 100 markers per sheet 209-113 1 sheet . . . or self-adhesive label, for self-marking, 7 x 25 pcs per sheet 210-345 1 sheet Protection cover, transparent 209-114 50 End stop, for DIN 35 rail 6 mm/0.236 in wide249-116 100 (4 x 25) 10 mm/0.394 in wide249-117 50 (2 x 25) ItemPack.-unit No.pcs Screwdriver with partially insulated shaft, type 1, blade 2.5 x 0.4 mm /0.098 in x 0.016 in, suitable for series 2001, 2000 210-719 1 type 2, blade 3.5 x 0.5 mm /0.137 in x 0.020 in, suitable for Series 2002, 2004 210-720 1 type 3, blade 5.5 x 0.8 mm /0.217 in x 0.031 in, suitable for Series 2006, 2010, 2016 210-721 1 Screwdrivers with partially insulated shaft, – set – types 1 – 3 210-722 1 Operating sticker for TOPJOB®S jumpers Size 80 mm x 101 mm Size 80 mm x 101 mm 1 3 4 Operating sticker for TOPJOB®S rail-mounted terminal blocks 1 2 3 4 Carrier rail 35 x 7.5 mm, 1 mm/0.039 in thick, acc. to EN 60715, Steel, IN 76 A (referred to a length of 1 m) max. 500V U2 300V TOPJOB®S tool with partially insulated shaft suitable for Series 2003, 2005 2009-310 1 0210-0400/2000-0002 0210- 0400/2000-0001 <_ 36 _> > < 5,2 <___ 27 ___> 1 > <_ > 7,5 < -20% 2001/2002/ 2004/ 2006/ 2010 /2016 <____ 35 ____> (_25_) 2000 ±1,5 ItemPack.-unit No.pcs 2 m /6’6” long Steel rail 35‑x‑7.5 mm, 1‑mm/0.039 in thick unslotted210-113 10 Steel rail 35‑x‑7.5 mm, 1‑mm/0.039 in thick 210-112 10 slotted ItemPack.-unit No.pcs Operating sticker, for TOPJOB®S rail-mounted terminal blocks Series 2001/2002/2004/2006/2010/2016 210-400/2000-0001 100 ItemPack.-unit No.pcs Operating sticker, for TOPJOB®S jumpers Series 2001/2002/2004/2006/2010/2016 210-400/2000-0002 100 93 ? Ferrules for Rail-Mounted Terminal Blocks and Crimping Tools Insulated ferrules, electrolytic copper, electro-tin plated, acc. to DIN 46228, part 4/09.90 < _ D1 > _ <__ D __> < D2 < Dimensions (in mm) <____ L1 ____> <___________ L __________> Insulated ferrules suitable for series 2001 – 2002 2001 – 2002 2002 – 2006 2001 – 2002 2002 – 2006 2001 – 2002 2002 – 2006 2010 – 2016 2002 2002 – 2006 2010 – 2016 2004 – 2006 2010 – 2016 2006 2010 – 2016 2010 – 2016 2016 Sleeve for Color Stripped L L1 D D1 D2 Item mm2 AWG length mmmmNo 0.5 22 white 12 16 10 3.12.61.0 216-241 0.7520 gray 12 16 10 3.32.81.2 216-242 0.7520 gray 14 18 12 3.32.81.2 216-262 1.0 18 red 12 16 10 3.53.01.4 216-243 1.0 18 red 14 18 12 3.53.01.4 216-263 1.5 16 black 12 16 10 4.03.51.7 216-244 1.5 16 black 14 18 12 4.03.51.7 216-264 1.5 16 black 20 24 18 4.03.51.7 216-284 2.5 14 blue 12 17 10 4.74.22.2 216-246 2.5 14 blue 14 19 12 4.74.22.2 216-266 2.5 14 blue 20 25 18 4.74.22.2 216-286 4.0 12 gray 14 20 12 5.44.82.8 216-267 4.0 12 gray 20 26 18 5.44.82.8 216-287 6.0 10 yellow14 20 12 6.96.33.5 216-208 6.0 10 yellow20 26 18 6.96.33.5 216-288 10.0 8 red 20 28 18 8.47.64.5 216-289 16.0 6 blue 23 28 18 9.68.85.8 216-210 Pack.-unit pcs 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 500 500 500 500 500 500 Notes: Twin ferrules are available. Contact WAGO for more information. ith the Variocrimp 4 built-in crimping pressure W plates control the crimping force automatically for the conductor cross section used. With the Variocrimp 16 it is necessary to select the wire gauge on the tool before crimping. ● Each tool has only one crimping station for all the wire sizes handled. ● Uniform compact crimping from all four sides for high conductor retention. ● No need to center the conductor in the ferrule sleeve. ● Conductor and ferrule insertion possible from both sides (for left- and right handed). ● Built-in ratchet to guarantee complete crimping every time. ● Tools open automatically after crimping operation is complete. ● Comfortable handles for operator. ● 94 Item Pack. unit No.pcs Variocrimp 4, Crimping tool for ferrules insulated and uninsulated, 0.25 mm2 – 4 mm2 / AWG 24 – 12 206-204 1 weight 400 g / 0.882 lbs Item Pack. unit No.pcs Variocrimp 16, Crimping tool for ferrules insulated and uninsulated, 6 mm2 – 16 mm2 / AWG 10 – 6 206-216 1 weight 580 g / 1.28 lbs ? Overview of Connectable Ferrules from 0.5 mm2 Series Rated crosssection in mm2 0.5 mm2 0.75 mm2 1 mm2 1.5 mm2 2001 0.25 – 1.5 (2.5) 216-241 216-242 216-243 216-244 2.5 mm2 4 mm2 6 mm2 10 mm2 16 mm2 –– –– –– –– –– 2002 0.25 – 2.5 (4) 216-241 216-242 216-243 216-244 216-246 –– –– –– –– 2003 0.25 – 2.5 (4) 216-241 216-242 216-243 216-244 216-246 –– –– –– –– 2004 0.5 – 4 (6) –– 216-262 216-263 216-264 216-266 216-267 –– –– –– 2005 0.5 – 4 (6) –– 216-262 216-263 216-264 216-266 216-267 –– –– –– 2006 0.5 – 6 (10) –– 216-262 216-263 216-264 216-266 216-267 216-208 –– –– 2010 0.5 – 10 (16) –– –– 216-286 216-287 216-288 216-289 2016 0.5 – 16 (25) –– –– 216-286 216-287 216-288 216-289 216-210 216-263 216-284 –– 216-284 –– TOPJOB®S Overview of Ferrules that can be Connected Directly (Push In) Series Rated cross section in mm2 0.5 mm2 2001 0.25 – 1.5 (2.5) –– 2002 0.25 – 2.5 (4) 2003 0.75 mm2 1 mm2 1.5 mm2 2.5 mm2 4 mm2 6 mm2 10 mm2 16 mm2 216-242 216-243 216-244 –– –– –– –– –– –– 216-242 216-243 216-244 216-246 –– –– –– –– 0.25 – 2.5 (4) –– 216-242 216-243 216-244 216-246 –– –– –– –– 2004 0.5 – 4 (6) –– 216-262 216-263 216-264 216-266 216-267 –– –– –– 2005 0.5 – 4 (6) –– 216-262 216-263 216-264 216-266 216-267 –– –– –– 2006 0.5 – 6 (10) –– –– –– 216-264 216-266 216-267 216-208 –– –– 2010 0.5 – 10 (16) –– –– –– –– 216-286 216-287 216-288 216-289 2016 0.5 – 16 (25) –– –– –– –– 216-286 216-287 216-288 216-289 216-210 –– 95 Convenient Marking With WMB Inline or Continuous Marking Strip – Quick and Easy 3M - PL 300 printer 96 The smartPRINTERTM offers quick and economical marking using the continuous marking strip...multiple lines of text is even possible. Cost-Efficient and Fast Marking Thermal transfer printer smartPRINTERTM Thermal printer 3M-PL300 Item No. Thermal transfer printerr, smartPRINTERTM Resolution 300 dpi 258-5000 Item No. 3M-PL300/thermal printer Resolution 180 dpi 258-6000 Includes: smartSCRIPT software, roller for marking strips, roller for marking WMB Inline (5mm), ink ribbon, 1 roll continuous marking strip and 1 roll WMB inline markers Marking material options: Polyester strips, 11mm wide – 5.5m long in cartridge 211-611 Marking strip, white for center marking WMB Inline TOPJOB®S group marker carriers TOPJOB®S marking adapters for WMB Module width 5 mm / 0. 197 in Module width 10 mm / 0.394 in Module width 15 mm / 0.59 1 in markers and continuous marking strip for marker cards and self-adhesive marker cards ItemPack.-unit No.pcs Marker strip, white, plain for center marking 11 mm wide, on roll 2009-110 50 m 1 WMB Inline, pitch 5 mm/ stretchable 5 mm – 5.2 mm, on roll white, 1,500 markers 2009-1151 WMB Inline, pitch 4 mm/ stretchable 4 mm – 4.2 mm, on roll white, 2,000 markers 2009-1141 ItemPack.-unit No.pcs TOPJOB®S group marker carrier, snap-on type for jumper slot 5 mm/0.197 in wide2009-191 50 50 10 mm/0.394 in wide2009-192 50 15 mm/0.591 in wide2009-193 suitable for: WAGO Multi marking system WMB, miniature WSB Quick marking system, marker strips, 11 mm wide ItemPack.-unit No.pcs Marking adapter for lateral marker receptacle gray 2009-198 200 2002-161 100 Marking adapter for jumper slots gray for marker cards and self-adhesive marker cards 2009-196 50 97 WAGO Multi Marking System WMB – Horizontal for 3.5 mm, 4 - 4.2 mm, 5 mm and wider terminal blocks Horizontal marking Consecutive numbers each strip 10 strips w ith 10 markers per card for terminal block widths 5 - 17.5 mm, 5 - 5.2 mm, 4 - 4.2 mm and 3.5 mm 1 Individual marking of 2002, 2022, 2004, 2006, 2010 and 2016 series terminal blocks 2 For continuous marking of 2002 and 2022 series terminal blocks. Individual marking of terminal blocks larger than 5/5.2 mm 3 For continuous marking of 2001 series terminal blocks 4 For continuous marking of 2000 series terminal blocks Marker Width 5 - 5.2 mm 2 Marker Width 4 - 4.2 mm 3 Marker Width 3.5 mm 4 1 . . . 10 (10x) 11 . . . 20 (10x) 21 . . . 30 (10x) 31 . . . 40 (10x) 41 . . . 50 (10x) 51 . . . 60 (10x) 61 . . . 70 (10x) 71 . . . 80 (10x) 81 . . . 90 (10x) 91 . . . 100 (10x) Marker Width 5 mm 1 793-502 793-503 793-504 793-505 793-506 793-569 793-570 793-571 793-572 793-573 793-5502 793-5503 793-5504 793-5505 793-5506 793-5569 793-5570 793-5571 793-5572 793-5573 793-4502 793-4503 793-4504 793-4505 793-4506 793-4569 793-4570 793-4571 793-4572 793-4573 793-3502 793-3503 793-3504 793-3505 793-3506 – – – – – 1 . . . 50 (2x) 51 . . . 100 (2x) 101 . . . 150 (2x) 151 . . . 200 (2x) 793-566 793-507 793-508 793-509 793-5566 793-5507 793-5508 793-5509 793-4566 793-4507 793-4508 793-4509 793-3566 793-3507 793-3508 793-3509 201 . . . 300 (1x) 301 . . . 400 (1x) 401 . . . 500 (1x) 501 . . . 600 (1x) 601 . . . 700 (1x) 701 . . . 800 (1x) 801 . . . 900 (1x) 901 . . .1000 (1x) 793-510 793-511 793-512 793-513 793-514 793-515 793-516 793-517 793-5510 793-5511 793-5512 793-5513 793-5514 793-5515 793-5516 793-5517 793-4510 793-4511 793-4512 793-4513 793-4514 793-4515 793-4516 793-4517 – – – – – – – – 1 . . . 9, ; (10x) 793-565 793-5565 793-4565 793-3565 for double deck terminal blocks 1, 3, 5, , . . . 99 and 2, 4, 6, . . . 100 (1x) 793-599 793-5599 793-5599 – 794-557 794-5557 – – 794-558 794-5558 – – Marking per card for triple deck terminal blocks 1, 4, 7, . . . 88 and 2, 5, 8, . . . 89 and 3, 6, 9, . . . 90 and 91, 94, 97, 92, 95, 98, 93, 96, 99, ; (1x) 100, 103, 106, . . . 187 and 101, 104, 107, . . . 188 and 102, 105, 108, . . . 189 and 190, 193, 196, 191, 194, 197, 192, 195, 198, ; (1x) Stretching of a strip, stretchable from 4 mm up to 4.2 mm for series 2001 stretchable from 5 mm up to 5.2 mm for series 2002 98 Separation of an individual marker from the strip, for series 2002 WAGO Multi Marking System WMB – Vertical for 3.5 mm, 4 - 4.2 mm, 5 mm and wider terminal blocks Vertical marking Consecutive numbers each strip 10 strips with 10 markers per card for terminal block widths 5 - 17.5 mm, 5 - 5.2 mm, 4 - 4.2 mm and 3.5 mm 1 Individual marking of 2002, 2022, 2004, 2006, 2010 and 2016 series terminal blocks 2 For continuous marking of 2002 and 2022 series terminal blocks. Individual marking of terminal blocks larger than 5/5.2 mm 3 For continuous marking of 2001 series terminal blocks 4 For continuous marking of 2000 series terminal blocks Marker Width 5 - 5.2 mm 2 Marker Width 4 - 4.2 mm 3 Marker Width 3.5 mm 4 1 . . . 10 (10x) 11 . . . 20 (10x) 21 . . . 30 (10x) 31 . . . 40 (10x) 41 . . . 50 (10x) 51 . . . 60 (10x) 61 . . . 70 (10x) 71 . . . 80 (10x) 81 . . . 90 (10x) 91 . . . 100 (10x) Marker Width 5 mm 1 793-602 793-603 793-604 793-605 793-606 794-601 794-602 794-603 794-604 794-605 793-5602 793-5603 793-5604 793-5605 793-5606 794-5601 794-5602 794-5603 794-5604 794-5605 793-4602 793-4603 793-4604 793-4605 793-4606 794-4601 794-4602 794-4603 794-4604 794-4605 on request 1 . . . 50 (2x) 51 . . . 100 (2x) 101 . . . 150 (2x) 151 . . . 200 (2x) 793-666 793-607 793-608 793-609 793-5666 793-5607 793-5608 793-5609 793-4666 793-4607 793-4608 793-4609 201 . . . 300 (1x) 301 . . . 400 (1x) 401 . . . 500 (1x) 501 . . . 600 (1x) 601 . . . 700 (1x) 701 . . . 800 (1x) 801 . . . 900 (1x) 901 . . .1000 (1x) 1001 . . .1100 (1x) 1101 . . .1200 (1x) 1201 . . .1300 (1x) 1301 . . .1400 (1x) 1401 . . .1500 (1x) 1501 . . .1600 (1x) 1601 . . .1700 (1x) 1701 . . .1800 (1x) 1801 . . .1900 (1x) 1901 . . .2000 (1x) 793-610 793-611 793-612 793-613 793-614 793-615 793-616 793-617 793-688 793-669 793-670 793-671 793-672 793-901 793-902 793-903 793-912 793-913 793-5610 793-5611 793-5612 793-5613 793-5614 793-5615 793-5616 793-5617 793-5688 793-5669 793-5670 793-5671 793-5672 793-5901 793-5902 793-5903 793-5912 793-5913 793-4610 793-4611 793-4612 793-4613 793-4614 793-4615 793-4616 793-4617 793-4688 793-4669 793-4670 793-4671 793-4672 793-4901 793-4902 793-4903 793-4912 793-4913 101, 101, 101, 102, . . .130, 130, 130 (1x) 131, 131, 131, 132, . . . 160, 160, 160 (1x) 793-667 793-668 793-5667 793-5668 793-4667 793-4668 for double deck terminal blocks 1, 3, 5, , . . . 99 and 2, 4, 6, . . . 100 (1x) 101, 103, 105, . . . 149 and 102, 104, 106, . . . 150 (2x) 793-669 793-900 793-5699 793-5900 793-4699 793-4900 794-657 794-5657 794-4657 794-658 794-5658 – Marking per card for triple deck terminal blocks 1, 4, 7, . . . 88 and 2, 5, 8, . . . 89 and 3, 6, 9, . . . 90 and 91, 94, 97, 92, 95, 98, 93, 96, 99, ; (1x) 100, 103, 106, . . . 187 and 101, 104, 107, . . . 188 and 102, 105, 108, . . . 189 and 190, 193, 196, 191, 194, 197, 192, 195, 198, ; (1x) 99 Marker cards, plain Marker strips WMB Multi marking system WMB Multi marking system ItemPack.-unit No.pcs WMB Inline marking system for 5 - 17.5 mm width, 10 strips with 10 markers per card plain ItemPack.-unit No.pcs WMB Inline marking system for 5 - 5.2 mm width, 10 strips with 10 markers per card plain 793-55015 793-5015 Marker cards in different colors: yellow 793-501/000-002 red 793-501/000-005 blue 793-501/000-006 gray 793-501/000-007 orange 793-501/000-012 light green 793-501/000-017 green 793-501/000-023 violet 793-501/000-024 5 5 5 5 5 5 5 5 ItemPack.-unit No.pcs WMB Inline marking system for 4 - 4.2 mm width, 10 strips with 10 markers per card plain 793-45015 Marker cards in different colors: yellow 793-5501/000-0025 red 793-5501/000-0055 blue 793-5501/000-0065 gray 793-5501/000-0075 orange 793-5501/000-0125 light green 793-5501/000-0175 green 793-5501/000-0235 violet 793-5501/000-0245 ItemPack.-unit No.pcs WMB multi marking system, 3.5 mm wide, 10 strips with 10 markers per card plain Marker cards in different colors: yellow 793-4501/000-0025 red 793-4501/000-0055 blue 793-4501/000-0065 gray 793-4501/000-0075 orange 793-4501/000-0125 light green 793-4501/000-0175 green 793-4501/000-0235 violet 793-4501/000-0245 100 WSB Quick marking system 793-35011 ItemPack.-unit No.pcs Miniature WSB Quick marking system, 5 mm wide, 10 strips with 10 markers per card plain 248-5015 Marker cards in different colors: yellow 248-501/000-002 red 248-501/000-005 blue 248-501/000-006 gray 248-501/000-007 orange 248-501/000-012 light green 248-501/000-017 green 248-501/000-023 violet 248-501/000-024 5 5 5 5 5 5 5 5 Marker carriers for WCB Combi Marking System Marking carriers for 4 WCB markers WCB Combi marking system 20 markers with identical numbers/letters each tag Item No. Pack.-unit pcs Marker carriers for 4 WCB markers 2009-184 suitable for terminal blocks with WMB marking receptable MarkingItem MarkingItem per tag No. per tag No. plain 1 (20x) 2 (20x) 3 (20x) 4 (20x) 5 (20x) 6 (20x) 7 (20x) 8 (20x) 9 (20x) 0 (20x) 249-200 249-201 249-202 249-203 249-204 249-205 249-206 249-207 249-208 249-209 249-210 1...0 (2x) 249-239 1. (20x) 2. (20x) 3. (20x) 4. (20x) 5. (20x) 6. (20x) 7. (20x) 8. (20x) 9. (20x) 0. (20x) 249-241 249-242 249-243 249-244 249-245 249-246 249-247 249-248 249-249 249-250 + (20x) – (20x) 249-237 249-238 Pieces per packing unit: 10 tags A (20x) B (20x) C (20x) D (20x) E (20x) F (20x) G (20x) H (20x) I (20x) J (20x) K (20x) L (20x) M (20x) N (20x) O (20x) P (20x) Q (20x) R (20x) S (20x) T (20x) U (20x) V (20x) W (20x) X (20x) Y (20x) Z (20x) 249-211 249-212 249-213 249-214 249-215 249-216 249-217 249-218 249-219 249-220 249-221 249-222 249-223 249-224 249-225 249-226 249-227 249-228 249-229 249-230 249-231 249-232 249-233 249-234 249-235 249-236 Insert WCB Combi marker into marker carrier ...and insert the marker carrier into the WMB marking receptacle of the terminal block 101 Approvals Item Approval- No. No. A list of approvals (update: catalog deadline) is provided on this page. Due to the numerous agencies and approvals as well as the ever-increasing number of new products, our online catalog provides you with complete up-to-date information at www.wago.com Vol- Cur-Cross tage rentSection V AAWG/mm2 UL – U Underwriters Laboratories USA 2001-120 . E45172 600 15 2001-1207E45172 2001-130 . E45172 600 15 2001-1307E45172 2001-140.E45172 600 15 2001-1407E45172 2002-120 . E45172 600 20 2002-1207E45172 2002-130 . E45172 600 20 2002-1307E45172 2002-140.E45172 600 20 2002-1407E45172 2002-22 . . E45172 300/600 20/5 2002-32 . . E45172 300/600 20/5 2004-120 . E45172 600 30 2004-1207E45172 2004-130 . E45172 600 30 2004-1307E45172 2004-140.E45172 600 30 2004-1407E45172 2006-120 . E45172 600 50 2006-1207E45172 2006-130 . E45172 600 50 2006-1307E45172 2016-120 . E45172 600 85 2016-1207E45172 2016-130 . E45172 600 85 2016-1307E45172 22-14 22-14 22-14 22-14 22-14 22-14 22-12 22-12 22-12 22-12 22-12 22-12 22-12 22-12 20-10 20-10 20-10 20-10 20-10 20-10 20-8 20-8 20-8 20-8 20-4 20-4 20-4 20-4 K N.V. tot Keuring van Elektro technische Materialien, Netherlands 2001-120 . NL2031569.05 800 18 2001-1207NL2031569.05 2001-130 . NL2031569.05 800 18 2001-1307NL2031569.05 2001-140 . NL2031569.05 800 18 2001-1407NL2031569.05 2002-120 . NL2086303.01 800 24 2002-1207NL2086303.01 2002-130 . NL2086303.01 800 24 2002-1307NL2086303.01 2002-140 . NL2086303.01 800 24 2002-1407NL2086303.01 2002-22 . . NL2086303.01 500 24 2002-32 . . NL2086303.01 500 24 2003-7641 NL2079570.51 250/400 32 2003-7642 NL2079570.51 400 32 2003-7645 NL2079570.51 250/400 32 2003-7646 NL2079570.51 250/400 32 2003-7649 NL2079570.51 400 32 2004-120 . NL2031569.08 800 32 2004-1207 NL2031569.08 2004-130 . NL2031569.08 800 32 2004-1307 NL2031569.08 2004-140 . NL2031569.08 800 32 2004-1407 NL2031569.08 2006-120 . NL2031569.03 800 41 2006-1207NL2031569.03 2006-130 . NL2031569.03 800 41 2006-1307NL2031569.03 2010-120 . NL2031569.02 800 57 2010-1207NL2031569.02 2010-130 . NL2031569.02 800 57 2010-1307 NL2031569.02 2016-120 . NL2031569.04 800 76 2016-1207 NL2031569.04 2016-130 . NL2031569.04 800 76 2016-1307 NL2031569.04 0,5-2,5 0,5-2,5 0,5-2,5 0,5-2,5 0,5-2,5 0,5-2,5 0,5-4 0,5-4 0,5-4 0,5-4 0,5-4 0,5-4 0,2-4 0,2-4 0,25-4 0,25-4 0,25-4 0,25-4 0,25-4 0,5-6 0,5-6 0,5-6 0,5-6 0,5-6 0,5-6 0,5-10 0,5-10 0,5-10 0,5-10 0,5-16 0,5-16 0,5-16 0,5-16 0,5-25 “f“ 0,5-25 “f“ 0,5-25 “f“ 0,5-25 “f“ CSA – Canadian Standard 2 Association Canada 2001-120 .154112-1645434 600 15 2001-1207 154112-1645434 2001-130 .154112-1645434 600 15 2001-1307 154112-1645434 2001-140 .154112-1645434 600 15 2001-1407 154112-1645434 2002-120 .154112-1536069 600 20 2002-1207 154112-1536069 2002-130 .154112-1536069 600 20 2002-1307 154112-1536069 2002-140 .154112-1536069 600 20 2002-1407 154112-1536069 2004-120 .154112-1645435 600 30 2004-1207 154112-1645435 2004-130 .154112-1645435 600 30 2004-1307 154112-1645435 2004-140 .154112-1645435 600 30 2004-1407 154112-1645435 2006-120 .154112-1543858 600 50 2006-1207 154112-1543858 2006-130 .154112-1543858 600 50 2006-1307 154112-1543858 2010-120 .154112-1645436 600 65 2010-1207 154112-1645436 102 22-14 22-14 22-14 22-14 22-14 22-14 22-12 22-12 22-12 22-12 22-12 22-12 20-10 20-10 20-10 20-10 20-10 20-10 20-8 20-8 20-8 20-8 20-6 20-6 Item Approval- No. No. Vol- Cur-Cross tage rentSection V AAWG/mm2 2010-130 .154112-1645436 600 65 2010-1307 154112-1645436 2016-120 .154112-1579112 600 85 2016-1207 154112-1579112 2016-130 .154112-1579112 600 85 2016-1307 154112-1579112 0 g 20-6 20-6 20-4 20-4 20-4 20-4 f LR – Lloyd’s Register of Shipping Great Britain 2002-120 . 91/20112(E3) 800 24 2002-120791/20112(E3) 2002-130 . 91/20112(E3) 800 24 2002-130791/20112(E3) 2002-140 . 91/20112(E3) 800 24 2002-140791/20112(E3) 2006-120 . 91/20112(E3) 800 41 2006-120791/20112(E3) 2006-130 . 91/20112(E3) 800 41 2006-130791/20112(E3) 2016-120 . 91/20112(E3) 800 76 2016-1207 91/20112(E3) 2016-130 . 91/20112(E3) 800 76 2016-1307 91/20112(E3) 0,5-4 0,5-4 0,5-4 0,5-4 0,5-4 0,5-4 0,5-10 0,5-10 0,5-10 0,5-10 0,5-25 “f“ 0,5-25 “f“ 0,5-25 “f“ 0,5-25 “f“ GL – Germanischer Lloyd Germany 2002-120 . 91/20112(E3) 800 24 2002-120791/20112(E3) 2002-130 . 91/20112(E3) 800 24 2002-130791/20112(E3) 2002-140 . 91/20112(E3) 800 24 2002-140791/20112(E3) 2006-120 . 91/20112(E3) 800 41 2006-120791/20112(E3) 2006-130 . 91/20112(E3) 800 41 2006-130791/20112(E3) 2016-120 . 91/20112(E3) 800 76 2016-1207 91/20112(E3) 2016-130 . 91/20112(E3) 800 76 2016-1307 91/20112(E3) 0,5-4 0,5-4 0,5-4 0,5-4 0,5-4 0,5-4 0,5-10 0,5-10 0,5-10 0,5-10 0,5-25 “f“ 0,5-25 “f“ 0,5-25 “f“ 0,5-25 “f“ DNV – Det Norske Veritas Denmark 2002-120 . E7570 800 24 2002-1207E7570 2002-130 . E7570 800 24 2002-1307E7570 2002-140 . E7570 800 24 2002-1407E7570 2006-120 . E7570 800 41 2006-1207E7570 2006-130 . E7570 800 41 2006-1307E7570 2016-120 . E7570 800 76 2016-1207 E7570 2016-130 . E7570 800 76 2016-1307 E7570 ABS 0,5-4 0,5-4 0,5-4 0,5-4 0,5-4 0,5-4 0,5-10 0,5-10 0,5-10 0,5-16 0,5-25 “f“ 0,5-25 “f“ 0,5-25 “f“ 0,5-25 “f“ ABS – American Bureau of Shipping USA 2001-120 . 05-HG476175/1-PDA800 18 2001-120705-HG476175/1-PDA 2001-130 . 05-HG476175/1-PDA800 18 2001-130705-HG476175/1-PDA 2001-140 . 05-HG476175/1-PDA800 18 2001-140705-HG476175/1-PDA 2002-120 . 05-HG476175/1-PDA800 24 2002-120705-HG476175/1-PDA 2002-130 . 05-HG476175/1-PDA800 24 2002-130705-HG476175/1-PDA 2002-140 . 05-HG476175/1-PDA800 24 2002-140705-HG476175/1-PDA 2004-120 . 05-HG476175/1-PDA800 32 2004-120705-HG476175/1-PDA 2004-130 . 05-HG476175/1-PDA800 32 2004-130705-HG476175/1-PDA 2004-140 . 05-HG476175/1-PDA800 32 2004-140705-HG476175/1-PDA 2006-120 . 05-HG476175/1-PDA800 41 2006-120705-HG476175/1-PDA 2006-130 . 05-HG476175/1-PDA800 41 2006-130705-HG476175/1-PDA 2010-120 . 05-HG476175/1-PDA800 57 2010-120705-HG476175/1-PDA 2010-130 . 05-HG476175/1-PDA800 57 2010-130705-HG476175/1-PDA 2016-120 . 05-HG476175/1-PDA800 76 2016-1207 05-HG476175/1-PDA 2016-130 . 05-HG476175/1-PDA800 76 2016-1307 05-HG476175/1-PDA Item Approval- No. No. 0,5-2,5 0,5-2,5 0,5-2,5 0,5-2,5 0,5-2,5 0,5-2,5 0,5-4 0,5-4 0,5-4 0,5-4 0,5-4 0,5-4 0,5-6 0,5-6 0,5-6 0,5-6 0,5-6 0,5-6 0,5-16 0,5-16 0,5-16 0,5-16 0,5-16 0,5-16 0,5-16 0,5-16 0,5-25 “f“ 0,5-25 “f“ 0,5-25 “f“ 0,5-25 “f“ Vol- Cur-Cross tage rentSection V AAWG/mm2 CENELEC CERTIFICATION AGREEMENT CCA-NL – N.V. tot Keuring van Elektrotechnische Materialien, Netherlands According to the CENELEC Certification Agreement, the CCA certificate is recognized in the following European countries: Belgium, Denmark, Germany, Greece, Spain, France, Ireland, Italy, Luxembourg, Netherlands, Austria, Portugal, Finland, Sweden, Great Britain, Czech Republic, Estonia, Cyprus, Latvia, Lithuania, Hungary, Malta, Poland, Slovenia, Slovakia 2001-130 . NL5724 800 18 2001-1307NL5724 2001-140 . NL5724 800 18 2001-1407NL5724 2002-120 . NL5851 800 24 2002-1207NL5851 2002-130 . NL5851 800 24 2002-1307NL5851 2002-140 . NL5851 800 24 2002-1407NL5851 2002-22 . . NL5851 500 24 2002-32 . . NL5851 500 24 2003-7641NL5828 250/400 32 2003-7642NL5828 400 32 2003-7645NL5828 250/400 32 2003-7646NL5828 250/400 32 2003-7649NL5828 2004-120 . NL5725 800 32 2004-1207NL5725 2004-130 . NL5725 800 32 2004-1307NL5725 2004-140 . NL5725 800 32 2004-1407NL5725 2006-120 . NL5551 800 41 2006-1207NL5551 2006-130 . NL5551 800 41 2006-1307NL5551 2010-120 . NL5755 800 57 2010-1207NL5755 2010-130 . NL5755 800 57 2010-1307NL5755 2016-120 . NL5555 800 76 2016-1207 NL5555 2016-130 . NL5555 800 76 2016-1307 NL5555 0,5-2,5 0,5-2,5 0,5-2,5 0,5-2,5 0,2-4 0,2-4 0,2-4 0,2-4 0,2-4 0,2-4 0,2-4 0,2-4 0,25-4 0,25-4 0,25-4 0,25-4 0,25-4 0,5-6 0,5-6 0,5-6 0,5-6 0,5-6 0,5-6 0,5-10 0,5-10 0,5-10 0,5-10 0,5-16 0,5-16 0,5-16 0,5-16 0,5-25 “f“ 0,5-25 “f“ 0,5-25 “f“ 0,5-25 “f“ PBundesanstalt Germany PTB Physikalisch Technische EEx e II 2001-120 .PTB05Atex1094U 550 16 0,5-2,5 with push-in type jumper bar max 17 A 2001-120 .IECEx PTB05.0034U 550160,5-2,5 with push-in type jumper bar max 17 A 2001-1207 PTB05Atex1094U 0,5-2,5 2001-1207 IECExPTB05.0034U 0,5-2,5 2001-130 .PTB05Atex1094U 550 16 0,5-2,5 with push-in type jumper bar 17 A 2001-130 .IECEx PTB05.0034U 550160,5-2,5 with push-in type jumper bar 17 A 2001-1307 PTB05Atex1094U 0,5-2,5 2001-1307 IECExPTB05.0034U 0,5-2,5 2001-140 .PTB05Atex1094U 550 16 0,5-2,5 with push-in type jumper bar 17 A 2001-140 .IECEx PTB05.0034U 550160,5-2,5 with push-in type jumper bar 17 A 2001-1407 PTB05Atex1094U 0,5-2,5 2001-1407 IECExPTB03.0004U 0,5-2,5 2002-120 .PTB03Atex1162U 550 22 0,2-4 with push-in type jumper bar 20 A 2002-120 .IECEx PTB03.0004U 550220,2-4 with push-in type jumper bar 20 A 2002-1207 PTB03Atex1162U 0,2-4 2002-1207 IECExPTB03.0004U 0,2-4 2002-130 .PTB03Atex1162U 550 22 0,2-4 with push-in type jumper bar 20 A 2002-130 .IECEx PTB03.0004U 550220,2-4 with push-in type jumper bar 20 A 2002-1307 PTB03Atex1162U 0,2-4 2002-1307 IECExPTB03.0004U 0,2-4 2002-140 .PTB03Atex1162U 550 22 0,2-4 with push-in type jumper bar 20 A 2002-140 .IECEx PTB03.0004U 550220,2-4 with push-in type jumper bar 20 A 2002-1407 PTB03Atex1162U 0,2-4 2002-1407 IECExPTB03.0004U 0,2-4 2004-120 .PTB05Atex1095U 550 30 0,5-6 with push-in type jumper bar 30 A 2004-120 .IECEx Item Approval- No. No. Vol- Cur-Cross tage rentSection V AAWG/mm2 PTB05.0033U 550300,5-6 with push-in type jumper bar max 30 A 2004-1207 PTB05Atex1095U 0,5-6 2004-1207 IECExPTB05.0033U 0,5-6 2004-130 .PTB05Atex1095U 550 30 0,5-6 with push-in type jumper bar max 30A 2004-130 .IECEx PTB05.0033U 550300,5-6 with push-in type jumper bar max 30 A 2004-1307 PTB05Atex1095U 0,5-6 2004-1307 IECExPTB05.0033U 0,5-6 2004-140 .PTB05Atex1095U 550 30 0,5-6 with push-in type jumper bar max 30 A 2004-140 .IECEx PTB05.0033U 550300,5-6 with push-in type jumper bar max 30 A 2004-1407 PTB05Atex1095U 0,5-6 2004-1407 IECExPTB05.0033U 0,5-6 2006-120 .PTB05Atex1030U 550 33 0,5-10 with push-in type jumper bar max 38 A 2006-120 .IECEx PTB05.0014U 550330,5-10 with push-in type jumper bar max 38 A 2006-1207 PTB05Atex1030U 0,5-10 2006-1207 IECExPTB05.0014U 0,5-10 2006-130 .PTB05Atex1030U 550 33 0,5-10 with push-in type jumper bar max 36 A 2006-130 .IECEx PTB05.0014U 550330,5-10 with push-in type jumper bar max 36 A 2006-1307 PTB05Atex1030U 0,5-10 2006-1307 IECExPTB05.0014U 0,5-10 2010-120 .PTB05Atex1070U 550 51 0,5-16 with push-in type jumper bar max 51 A 2010-120 .IECEx PTB06.0003U 550510,5-16 with push-in type jumper bar max 51 A 2010-1207 PTB05Atex1070U 0,5-16 2010-1207 IECExPTB06.0003U 0,5-16 2010-130 .PTB05Atex1070U 550 50 0,5-16 with push-in type jumper bar max 50 A 2010-130 .IECEx PTB06.0003U 550500,5-16 with push-in type jumper bar max 50 A 2010-1307 PTB05Atex1070U 0,5-16 2010-1307 IECExPTB06.0003U 0,5-16 2016-120 .PTB05Atex1031U 550 33 0,5-25 with push-in type jumper bar max 70 A 2016-120 .IECEx PTB05.0015U 550330,5-25 with push-in type jumper bar max 70 A 2016-1207 PTB05Atex1031U 0,5-25 2016-1207 IECExPTB05.0015U 0,5-25 2016-130 .PTB05Atex1031U 550 33 0,5-25 with push-in type jumper bar max 67 A 2016-130 .IECEx PTB05.0015U 550330,5-25 with push-in type jumper bar max 67 A 2016-1307 PTB05Atex1031U 0,5-25 2016-1307 IECExPTB05.0015U 0,5-25 c URus – Y Underwriters Laboratories USA 2001-120 . E185892 550 15 2001-1207E185892 2001-130 . E185892 550 15 2001-1307E185892 2001-140 . E185892 550 15 2001-1407E185892 2002-120 . E185892 550 20 2002-1207E185892 2002-130 . E185892 550 20 2002-1307E185892 2002-140 . E185892 550 20 2002-1407E185892 2004-120 . E185892 550 30 2004-1207E185892 2004-130 . E185892 550 30 2004-1307E185892 2004-140 . E185892 550 30 2004-1407E185892 2006-120 . E185892 550 50 2006-1207E185892 2006-130 . E185892 550 50 2006-1307E185892 2016-120 . E185892 550 85 2016-1207E185892 2016-130 . E185892 550 85 2016-1307E185892 22-14 22-14 22-14 22-14 22-14 22-14 22-12 22-12 22-12 22-12 22-12 22-12 20-10 20-10 20-10 20-10 20-10 20-10 20-8 20-8 20-8 20-8 20-4 20-4 20-4 20-4 103 Germany WAGO Kontakttechnik Minden Tel. ++49/571/887/0 Fax ++49/571/887/169 Austria WAGO Kontakttechnik Wien Tel.++43/1/615/07/80 Fax++43/1/615/07/75 Belgium WAGO Kontakttechnik Zaventem Tel.++32/2/7/17/90/90 Fax++32/2/7/17/90/99 51288667 0888-0832/0000-0309 Printed in the United States WAGO Service Worldwide China WAGO ELECTRONIC Co. Ltd. Tianjin Tel ++86/22/59617688 Fax++86/22/59617668 England WAGO, Ltd. Rugby Tel.++44/1788/568008 Fax++44/1788/568050 France WAGO CONTACT S.A. Paris Tel.++33/148172590 Fax++33/148632520 Italy WAGO ELETTRONICA SRL Casalecchio di Reno (BO) Tel.++39/051/6132112 Fax++39/051/6272174 Japan WAGO Co. of JAPAN Ltd. Tokyo Tel.++81/3/5627/2050 Fax ++81/3/5627/2055 Poland WAGO ELWAG sp. z o. o. Wroclaw Tel.++48/71/3604670/78 Fax++48/71/3604699 Singapore WAGO Electronic Pte. Ltd. Singapore Tel.++65/62866776 Fax++65/62842425 Switzerland WAGO CONTACT SA Domdidier Tel.++41/26/676/75/86 Fax++65/26/676/75/01 Mexico WAGO Corporation Queretaro Tel. 001/800/309/5975 + 52/442/221/5946 Fax + 52/442/221/5063 Canada WAGO Corporation Tel. 800/DIN Rail (346-7245) Fax 262/255-3232 www.wago.ca WAGO Corporation N120 W19129 Freistadt Road Germantown, Wisconsin 53022 Telephone: 800 / DIN Rail (346-7245) Fax: 262 / 255-3232 info.us@wago.com www.wago.us