Rosen Shingle Creek Resort Hotel
Transcription
Rosen Shingle Creek Resort Hotel
Rosen Shingle Creek Resort Hotel CASE STUDY CLIENT: REPRESENTATIVE OFFICE: ARCHITECT/DESIGNER: LOCATION: Rosen Shingle Creek Resort Tom Barrow Company Orlando Helman Hurley Charvat Peacock Orlando, Florida ABOUT THE PROJECT Rosen Shingle Creek Resort in Orlando is situated on 230-acres of lush landscape and is Central Florida’s newest and most luxurious meeting destination. The state-of-theart hotel includes 1,500 guest rooms and suites, 445,000 square feet of technologically advanced event or meeting space, a 13,000 square foot spa, and several other amenties to numerous to mention. Designed to reflect early 1900 Spanish Revival style architecture, the hotel provides a glimpse into what life was like in the early years in Florida. The history of Shingle Creek reveals the captivating tale of how its majestic cypress trees provided some much needed shelter for early settlers and their homes. Today, the stunning grand lobby welcomes you into a world of lavish choices, complete with luxury accommodations, enticing restaurants and a championship golf course. VS Titus - The Leader in Air Management | www.titus-hvac.com THE TITUS SOLUTION Titus was the successful supplier of 1760 Vertical Stack fan coils for all the hotel rooms at the Rosen Shingle Creek Resort. However due to very specific requirements from the resort owner a number of “special options” had to be incorporated into the standard Titus Vertical Stack fan coil to achieve a number of energy and installation cost savings. The primary special option and probably the most challenging to incorporate into a fan coil due to the high humidity in Orlando was the introduction and treatment of direct fresh air to the unit. This option not only provided substantial financial savings on the equipment and installation but also reduced the space required to layout the additional ductwork for a secondary fresh air system supplied by dedicated air handling units typically installed in the building roof. The solution to the challenge was the addition of a secondary “Wild Coil” in each unit with all the necessary controls which not only tempered the fresh air introduced directly from outside into each room but also removed the excessive humidity particularly during the summer months. A washable filter was also part of the proposal to ensure that reasonable clean air was introduced into each room and minimize the financial impact of replacing throwaway filters. Titus - The Leader in Air Management | www.titus-hvac.com Being a Vertical Stack installation type, the typical method of connecting the risers between units at each floor is to braze the riser pipes, however in this installation and due to the fast track delivery required by the building owner, press type fittings were used on all floors with substantial financial savings and reduced installation time. In coordination with Coastal Mechanical Services LL, Titus had to increase the spacing between the risers to allow the press tool to clamp the fittings into the riser pipes. Lastly and in order to achieve the highest energy cost savings, a specific thermostat was selected that cycled the fan/motor on and off at specific set points as specified by KLG/Orlando in order to meet the energy savings required by the resort owners. THE END RESULT The Rosen Shingle Creek Resort Hotel is an example of a typical success story when all parties involved collaborate and work toward a common goal. It is also an impressive structure that honors the location and history in which it was constructed while incorporating new building technology for the current generation of guests to experience. Titus - The Leader in Air Management | www.titus-hvac.com Titus Products List Titus Vertical Stack (VS) Fan Coil units are designed for free-blow or ducted, concealed installations, suitable for hotel, motel and apartment building applications. VS Titus - The Leader in Air Management | www.titus-hvac.com