11-MPC Series

Transcription

11-MPC Series
10A
10A
Miniature PCB Power Filters
MPC Series
Tested and found to be
IAW VDE 0565 Part 3
61-MPC Series
Rugged construction design enables parts to perform in
industrial environments. The 61-MPC series is ideally
suited for products that must conform to FCC part 15
regulations. Agency approvals: UL recognized, CSA
certified, TUV approved (tested and found to be in
accordance with VDE 0565 Part 30. Applications include;
■
■
■
■
■
■
Personal computers and peripherals
Measuring instruments
Home appliances and vacuum cleaners
Monitor and display units
Switching power supplies
Available lead free/RoHs Compliant
Circuit Diagrams
Circuit 1
Circuit 2
Power filters are available in PCB mount, bolt-in, fast-on
tab or solder lug. The 11-MPC series is ideally suited for
products that have been limited board space and require
a low cost alternative. Available in both metal and plastic
cases. Applications include;
■
■
■
■
■
Personal computers and peripherals
Digital equipment
Measuring instruments and medical equipment
TV & VCR monitors and display units
Available lead free/RoHs Compliant
Circuit 3
Circuit 4
MPC Power EMI Filters
11-MPC Series
MPC-010/-015 Series
The compact design of the MPC-010 and -015 series
power filters integrates a feed thru capacitor, multilayer
ceramic capacitor and ferrite bead inductors. This series
is ideally suited for dense PCBs and where both positive
and negative lines have reduce EMI in one housing.
Applications include;
■
■
■
■
■
■
Circuit 5
DC power lines on industrial equipment
Measuring instruments
Home appliances and vacuum cleaners
Monitor and display units
Switching power supplies
Available lead free/RoHs Compliant
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.specemc.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
55
Miniature PCB Power Filters
MPC Series
Specifications
Rated Voltage
(@ 50/60Hz)
Model
Rated
Current
61-MPC-010-1-11
Leakage Current
(Max.)
1.6A
250VAC
61-MPC-025-1-11
6.0mH
0.1mA
2.5A
61-MPC-036-1-11
Temperature
Rise (Max.)
Circuit
Diagram
Figure
40˚C
1
A
2
C
11mH
1A
61-MPC-016-1-11
Inductance
(L1)
2.4mH
1.2mH
3.6A
11-MPC-001-2-B
5uA
1A
11-MPC-001-5-A
B
11-MPC-001-5-B
3
C
11-MPC-002-5-B
11-MPC-002-5-D
2A
120/250VAC
11-MPC-006-5-B
6A
F
3
0.2mA
16A
11-MPC-016-5-B
MPC-010-050
50 VDC
MPC-010-250
250 VDC
MPC-015-050
50VDC
10A
D
4
C
5
G
15A
Note: Test voltage: 1500VAC one minute, line to ground. Insulation resistance: 300 MΩ min. at 500VDC. Voltage drop: 1V max. at rated current. Weight: 17.5g
Figure B
4 — .031 (.8)
4
3
Figure A
2
1
0.6 0.9
(16) (25)
.551 (14)
.767 (19.5)
.059 (1.5)
1.239 (31.5)
.767 (19.5)
0.6
(16)
0.9 (25)
.590 (15)
.354 (9)
Figure C
0.6
(15)
Figure D
0.03 (1) (5X)
.30 (7.5)
1.9 (30)
.30 (7.5)
0.9 (25) 2.0
± .007 (51)
0.9 (25)
2.5 (64)
1.4 (36)
0.6
(15)
±.03
1.4 (35.5)
1.9 (49)
1.1 (27)
.15 (4)
0.03
(0.8)
0.03
(0.7)
.60
(15)
±.07
1.1
(28)
0.6
0.6
(16) (15)±.07
1.4 (36)
1.8 (45)
0.45 (11.5)
0.65 (16.6)
.45
(11.5) 1.4
(35)
.45
(11.5)
0.17 (4.4) 0.48 (12.1)
Figure G
0.3 (8)
0.3 (8)
.79 (20)
1.1 (29)
1.7 (44)
0.45 (11.5)
Figure F
0.4
(10)
Figure E
.03 (1) (5X)
0.03 (0.8)
0.03 (0.8)
0.03 (0.7)
0.10 0.10 0.10
(2.5) (2.5) (2.5)
56
E
4
C
11-MPC-006-5-C
MPC Power EMI Filters
30°C
0.50mA
3A
11-MPC-003-5-E
0.10 0.10
(2.5) (2.5)
0.03 (0.8)
0.6±0.1
Dimensions in inches (mm)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.specemc.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Miniature PCB Power Filters
MPC Series
61-MPC Series
Common Mode
120
1
3
Filter
2
4
Oscillator
50Ω
50Ω
Level
Meter
50Ω
1
3
Filter
2
4
(Test circuit 2)
Oscillator
50Ω
100
Current (%)
Common
mode with
Y cap.
(Test circuit 1)
Temperature Characteristics
50Ω
Level
Meter
50Ω
80
60
40
20
0
0
30
61-MPC
80
90
100
Y Cap
2 X 3300pF
70
61-MPC-010-1-11
Normal Mode
60
50
1
3
Filter
2
4
40
(Test circuit 3)
61-MPC-016-1-11
30
61-MPC-025-1-11
Oscillator
50Ω
20
50Ω
50Ω
Level
Meter
50Ω
MPC Power EMI Filters
Insertion Loss (dB)
40
50
60
70
80
Ambient Temperature (°C)
61-MPC-036-1-11
10
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
61-MPC
61-MPC
80
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
61-MPC-010-1-11
50
40
30
61-MPC-016-1-11
20
0.5
1
61-MPC-010-1-11
40
61-MPC-016-1-11
30
61-MPC-025-1-11
20
10
61-MPC-036-1-11
0.2
50
61-MPC-036-1-11
61-MPC-025-1-11
10
0
0.1
60
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.specemc.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
57
Miniature PCB Power Filters
MPC Series
11-MPC Series
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
50Ω
50Ω
Level
Meter
50Ω
11-MPC-001;-002
11-MPC-001;-002
80
80
11-MPC-002-5-D
70
70
11-MPC-001-5-A
60
Insertion Loss (dB)
Insertion Loss (dB)
11-MPC-001-5-B
11-MPC-001-2-B
50
40
11-MPC-002-5-D
30
20
60
11-MPC-001-5-B
50
11-MPC-001-2-B
40
30
20
11-MPC-001-5-A
11-MPC-002-5-B
10
10
11-MPC-002-5-B
0
0.1
0.2
1
0.5
2
5
10
20
0
0.1
50
0.2
0.5
1
5
10
20
50
Frequency (MHz)
Frequency (MHz)
11-MPC-003;-006;-016
11-MPC-003;-006;-016
80
80
70
70
11-MPC-006-5-C
60
Insertion Loss (dB)
Insertion Loss (dB)
MPC Power EMI Filters
2
11-MPC-003-5-E
50
11-MPC-006-5-B
40
30
11-MPC-016-5-B
20
60
11-MPC-016-5-B
50
11-MPC-003-5-E
40
30
11-MPC-006-5-C
20
11-MPC-006-5-B
10
0
0.1
10
0.2
1
0.5
2
5
10
20
50
Frequency (MHz)
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
MPC-010 & 015 Series
100
Insertion Loss (dB)
90
80
MPC-010-050
MPC-015-050
70
60
50
40
MPC-010-250
30
20
10
0
0.01
0.1
1
10
100
1000
10000
Frequency (MHz)
58
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.specemc.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
Bolt-in Right Angle Terminals
for PCB Applications
60-BPP Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
PCB Power Filters
■
■
■
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Solder lug, Fast-on tab styles available (see page 26)
PCB mounting style minimizes space and provides
economical installation
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 55)
UL approved low leakage version also available
■
■
■
3
1
CY
L1
CX
E
E
Applications
■
Circuit Diagram
CY
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
2
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BPP-010-3-2
60-BPP-010-3-4
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF
0.50mA
3300pF
60-BPP-020-3-2
0.35mA
60-BPP-020-3-4
2200pF
0.50mA
3300pF
0.022uF
2.4mH
30°C
0.022uF
0.047uF
250VAC
60-BPP-030-3-2
0.35mA
2200pF
0.022uF
0.047uF
3A
60-BPP-030-5-2
0.50mA
3300pF
0.047uF
60-BPP-060-3-2
0.022uF
0.35mA
2200pF
0.047uF
6A
60-BPP-060-5-2
60-BPP-060-5-4
0.50mA
3300pF
1.2mH
0.022uF
60-BPP-030-5-4
60-BPP-060-3-4
6.0mH
0.022uF
0.047uF
2A
60-BPP-020-5-2
60-BPP-030-3-4
Temperature
Rise (Max.)
0.047uF
60-BPP-010-5-4
60-BPP-020-5-4
Inductance
(L1)
0.022uF
0.047uF
1A
60-BPP-010-5-2
CX
0.53mH
45°C
0.022uF
0.047uF
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
54
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
Bolt-in Right Angle Terminals
for PCB Applications
60-BPP Series
.098 (2.5)
120
Current (%)
100
1.463 (37.2)
1.967 (50)
1.317
(33.5)
1.573 (40)
.885
(22.5)
2- .142
(3.6)
80
.047 (1.2)
.232 (5.9)
60
.024
(.6)
5
.
R4
.865
(22)
40
2- .142
(3.6)
1.573 (40)
* General
tolerance
± .012 (.3)
.142
.059 (3.6)
(1.5)
.031 (.8)
1.070
(27.2)
1.180 (30)
.779 1.180
(19.8) (30)
.708
(18)
Panel cutout dimensions
mounts from backside
20
0
.991
(25.2)
.590 (15)
20
30
40
50
60
70
Ambient Temperature (°C)
80
Dimensions in inches (mm)
90
Common Mode
PCB Power Filters
Temperature Characteristics
60-BPP
PCB
Mounting
Type
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
50Ω
50Ω
Level
Meter
50Ω
60-BPP-010;-020
60-BPP-010;-020
80
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
60-BPP-010-3-X
50
60-BPP-020-3-X
40
30
20
60-BPP-010-X-4
50
40
30
60-BPP-020-X-4
20
10
10
0
0.1
60
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
5
10
20
50
20
50
60-BPP-030;-060
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
60-BPP-030;-060
80
60-BPP-030-3-X
50
40
60-BPP-060-3-X
30
20
10
0
0.1
2
Frequency (MHz)
60
50
40
60-BPP-030-X-4
30
60-BPP-060-X-4
20
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
55
Power Entry Modules
High Frequency Attenuation
Bolt-in for PCB Applications
60-BHP Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
PCB Power Filters
■
■
■
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Solder lug, Fast-on tab styles available (see page 28)
PCB mounting minimizes space and provides
economical installation
Excellent filtering characteristics for high frequencies
Earth coil standard
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 57)
Circuit Diagram
■
■
■
CY
L1
Applications
■
3
1
CX
E
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
2
4
L2
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BHP-010-3-11
Leakage Current
(Max.)
0.35mA
60-BHP-010-3-4
Capacitance
CY
2200pF±20%
0.50mA
3300pF±20%
60-BHP-010-5-4
0.35mA
60-BHP-020-3-4
2200pF±20%
0.50mA
3300pF±20%
0.35mA
2200pF±20%
2.4mH
0.50mA
3300pF±20%
60-BHP-030-5-4
30°C
0.1uF±20%
18.3 uH
0.1uF±20%
.047uF±20%
3A
60-BHP-030-5-11
1.2mH
0.1uF±20%
.047uF±20%
60-BHP-060-3-11
60-BHP-060-5-11
0.1uF±20%
.047uF±20%
250VAC
60-BHP-030-3-11
60-BHP-060-3-4
6mH
0.1uF±20%
.047uF±20%
2A
60-BHP-020-5-11
60-BHP-030-3-4
Temperature
Rise (Max.)
.047uF±20%
60-BHP-020-3-11
60-BHP-020-5-4
Inductance
(L1)
(L2)
0.1uF±20%
.047uF±20%
1A
60-BHP-010-5-11
CX
0.35mA
2200pF±20%
0.1uF±20%
.047uF±20%
6A
0.50mA
60-BHP-060-5-4
3300pF±20%
0.53mH
45°C
0.1uF±20%
.047uF±20%
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
56
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
Power Entry Modules
High Frequency Attenuation
Bolt-in for PCB Applications
60-BHP Series
120
.991
(25.2)
.590 (15)
2- .142
(3.6)
.5
2- .142
(3.6)
1.573 (40)
40
.059
(1.5)
.031 (.8)
1.070
(27.2)
.024
(.6)
R4
.865
(22)
.142
(3.6)
.047 (1.2)
.232 (5.9)
1.180 (30)
80
60
1.534 (39)
1.389
(35.3)
.885
(22.5)
100
Current (%)
.098
(2.5)
1.967 (50)
1.573 (40)
.779 1.180
(19.8) (30)
.708 (18)
Panel cutout dimensions
mounts from backside
20
Dimensions in inches (mm)
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
90
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
60-BHP-XXX-X-11
90
80
Insertion Loss (dB)
Insertion Loss (dB)
60-BHP-020-X-11
50
40
60-BHP-030-X-11
30
60-BHP-060-X-11
60-BHP-010-3-11
50
60-BHP-020-3-11
40
60-BHP-030-3-11
30
60-BHP-060-3-11
10
10
1
0.5
60-BHP-XXX-3-11
60
20
0.2
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
90
5
10
20
50
60-BHP-XXX-3-4
90
80
80
60-BHP-010-X-4
70
Insertion Loss (dB)
Insertion Loss (dB)
2
Frequency (MHz)
60-BHP-XXX-X-4
60-BHP-020-X-4
60
50
40
60-BHP-030-X-4
30
60-BHP-060-X-4
70
60-BHP-010-3-4
60
50
60-BHP-020-3-4
40
60-BHP-030-3-4
30
60-BHP-060-3-4
20
20
10
10
0
0.1
50Ω
Level
Meter
50Ω
70
20
0
0.1
50Ω
80
60-BHP-010-X-11
70
60
PCB Power Filters
60-BHP
PCB
Mounting
Type
Temperature Characteristics
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
57