EDGE - Pinnacle Architectural Lighting

Transcription

EDGE - Pinnacle Architectural Lighting
EDGE EV3A
E V O L U T I O N
LED Recessed Linear with
Satine Lens
Project Name
Date
Catalog Number
Type
CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Highly reflective
die-formed white painted steel reflector, .125” (3.2mm) white snap-in acrylic lens with matte finish, removable for
maintenance.
ELECTRICAL Electronic, 120 to 277 volt input and 36V output. 0-10 volt dimming standard. Must specify 1D in circuiting
for dimming.
LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80.
R9≥20, 27K is CRI≥90, 30K, 35K, and 40K is CRI≥82. Minimum lifetime greater than 60,000 hours.
MOUNTING Edge is designed to install into acoustical grid and inaccessible ceilings. Specify GXG, FLF, SFS, NFN for
individual, unjoinable units (individual units will fall on-grid). Specify GX, FL, SF, NF for continuous runs (runs designed
to fall on-grid). Grid retention brackets are integral to housing. Each housing contains 4 grid retention brackets. Consult
factory for detailed installation instructions.
FINISH Standard powder-coat textured white, metallic silver, textured black, graphite or bronze painted finish, consult
factory for chip of standard paint finishes. Contact factory for additional custom color and finish options.
WARRANTY Edge LED offered with a 5-year limited warranty. Covers LED, driver and fixture.
LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted.
YEAR LED
WARRANTY
Daylight
Sensor
MR16
Corners
LFL
Convertible
LED
5-1/8”
5-1/8”
(130.2mm)
LED
Convertible
YEAR LED
WARRANTY
LFL
3” (76.2mm)
G1/G9/GS:
3-13/16”
3-13/16”
(96.8mm)
LFL
FL
& FLF:
Convertible
4-1/8” (104.8mm)LED
L U M I N A I R E S P E C I F I C AT I O N
EV3A-
____-
___’-
HOUSING
COLOR/LUMENS
LENGTH
LFL
Sample Catalog #: EV3A-30-24’-FL-120-1C-W
___-
___-
__-
__-
____
VOLTAGE
CIRCUITING
FINISH
OPTIONS
YEAR LED
WARRANTY
MOUNTING1
LFL
Individual Units2
2- 2’, 23” (584.2mm) fixture2
3- 3’, 35” (889mm) fixture2
4- 4’, 47” (1193.8mm) fixture2
27K Color Temperature Lumen Options 5- 5’, 59” (1498.6mm) fixture2
27- 27K, 302 lumens/ft (5.2 watts/ft)
6- 6’, 71”YEAR
(1803.4mm)
fixture2
LED
27HO- 27K, 547 lumens/ft (9.9 watts/ft)
WARRANTY
8- 8’, 95” (2413mm) fixture2
Staggered
30K Color Temperature Lumen
Options
Lamps
Continuous Runs3
30- 30K, 368 lumens/ft (5.2 watts/ft)
xx’- Specify
row length to LED
1’ increments
LFL
30HO- 30K, 665 lumens/ft (9.9 watts/ft)
EV3A- Edge
Evolution 3,
Satine Lens
LED
Convertible
Convertible
LED
120- 120 V
277- 277 V
UNV- UNV
(120-277)
LED
Convertible
LFL
1C- Single Circuit
1D- Single Circuit Dimming5
1B- Single Circuit with
Battery Pack5,9
1E- Single Circuit with
Emergency Circuit
Individual Units (CANNOT BE JOINED)2
Acoustical Grid Ceiling14
G1G- 1” (25.4mm) Ceiling Grid
Convertible
Convertible
(Utilize Illuminated [EI] or Non-Illuminated
LED
LFL
35K Color Temperature Lumen Options
G9G- 9/16” (14.3mm) Ceiling Grid
[EN] Extension in the Options section to
Staggered
35- 35K, 384 lumens/ft (5.2
watts/ft)
Lamps
specify rows to 1/8” increments)
GBG- 9/16” (14.3mm) Ceiling Grid with Bevel Trim
Installation
35HO- 35K, Instructions
695 lumens/ft (9.9 watts/ft)
GSG- Screw Slot Ceiling Grid
Inaccessible Ceiling
40K Color Temperature Lumen Options
FLF- Standard5-1/8”
1/2” (127.mm) Flange
40- 40K, 394 lumens/ft (5.2 watts/ft)
SFS- Spackle(130.2mm)
Flange
40HO- 40K, 713 lumens/ft (9.9 watts/ft)
NFN- Flangeless4
Year LED
Custom Output
Warranty
Continuous Runs (JOINABLE)3
CL_____- Specify color temp. and lumens/ft. (i.e. CL35600)
Acoustical Grid Ceiling14
CW____- Specify color temp. and wattage/ft. (i.e. CW407.5)
G11” (25.4mm) Ceiling Grid
3”
(76.2mm)
(Specify lumens/watts between standard offering listed above.
G9- 9/16” (14.3mm) Ceiling Grid
LFL Lumens are specifiedLED
per color temp.)
G1/G9/GS:
Convertible
Convertible
GB- (96.8mm)
9/16” (14.3mm) Ceiling Grid with Bevel Trim
3-13/16”
LED
LFL
FL
& FLF:Screw Slot Ceiling Grid
GS(104.8mm)
4-1/8”
Inaccessible
Ceiling
FL- Standard 1/2” (12.7mm) Flange
SF- Spackle Flange
NF- Flangeless4
W- Matte White
S- Metallic Silver
BL- Textured Black
GR- Graphite
BR- Bronze
CC- Custom Color
QSCPMRFLMRFPMRCEV3CHEV3CIEV3COEI__EN__-
Quick Ship12
Chicago Plenum
Fixed MR16 Halogen8
Fixed MR16 LED8
Perimeter Mount6
Rotating Crossbar7
90° Horizontal Corner10
90° Inside Corner10
90° Outside Corner10
Factory Installed
Illuminated Extension11
Factory Installed NonIlluminated Extension13
See back page for mounting detail. 2Individual units cannot be joined. All end trims are factory installed and cannot be removed in the field. 3Continuous Rows made up of both even and odd length fixtures. Designed to fall on-grid. 4NF and NFN to be utilized for metal pan / millwork ceiling. 5Some Edge configurations will not accommodate all electrical options. Consult factory. 6Available for acoustical
grid ceilings. Wall rail painted white unless otherwise specified. 71/2” to 5/8” drywall thickness. Available for standard 1/2” flange (FL). 8Consult MR16 Resource Guide for configurations using MR16 units.
9
Integral battery packs with remote test switch are provided with 1B option. 10See EV3 corner specification sheet for more 5-1/8”
information. 11Use “__” to specify desired length. Minimum length is 3”. Sample
(130.2mm)
part number EV3A-27-24-G1-120-1C-W-EI4 for order a 24’-4” run. 12Includes EV3A, 4 ft individual, unjoinable units, G1G and
FLF mounts, universal voltage, std white finish, 1C and 2C circuiting. 13Use “__”
to specify desired length. Minimum length is .5”. Sample part number EV3A-27-24-G1-120-1C-W-EN2 for order a 24’-2” run. 14 See page 3 for grid retention bracket details.
1
®
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Fax 303.322.5568 www.pinnacle-ltg.com
Phone 303.322.5570
3” (76.2mm)
© 2016 Pinnacle Architectural Lighting®
G1/G9/GS:
3-13/16” (96.8mm)
August 2016
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com
FL & FLF: are the most recent version and supersede all other previously printed or electronic versions.
4-1/8” (104.8mm)
P H O T1”O Grid
M E Mounting
TRY
Options
Mounting
1119
619
2'
E D G E E VScrew
O L USlot
TION
9/16” Grid Mounting Options
EV3C, EV3D
23" (584.2mm)
464
839
310
(1) lens per 2'155
unit
560
59” (1498.6mm) or 60” (1524mm)
5'
280
35" (889mm)
(1) lens per 5' unit
71” (1803.4mm) or 72” (1828.8mm)
3'
6'
4'
8'
(1) lens per 6' unit
lens per 3' unit
1” Grid,(1)Standard
Tile: 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile:
Screw Slot Grid:
(1193.8mm)
or 48”
(2413mm)
96” GS
(2438.4mm)
Use G1 or47”
G1G
in part # Use
G1 (1219.2mm)
or G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or95”
GBG
in part #or Use
or GSG in part # Use GS or GSG in part #
(1) lens per 8' unit
per 4' unit
Test(1)#:lens
ILT82918
Test #: ITL82919
Part #: EV3A-40-4’
Part
#:
EV3A-40HO-4’
1Acoustical
Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings.
Lumens per watt: 76
Lumens per watt: 71
Perimeter Mount
Flange Detail
Non-Flange
Spackle Flange
Total Delivered Lumens: 1574
Total Delivered Lumens: 2851
Rotating Crossbar
EV3A, EV3AL,
INDIVIDUAL
ANDEV3H
CONTINUOUS RUN MODULES 1
59” (1498.6mm) or 60” (1524mm)
23" (584.2mm)
2'
5'
(1) lens per 2' unit
35" (889mm)
Exposed Flange Detail:
Metal Pan or Millwork:
Drywall, Flangeless Look:
6' #
Specify NF or NFN in part # Specify SF or SFS in part
3'Specify FL or FLF in part #
(1) lens per 3' unit
(1) lens per 5' unit
71” (1803.4mm) or 72” (1828.8mm)
Bracket and Wall Rail:
Specify PM in part #
(1) lens per 6' unit
47” (1193.8mm) or 48” (1219.2mm)
4'
Unavailable Structure Support:
Specify RC in part #
95” (2413mm) or 96” (2438.4mm)
8'
(1) lens per 4' unit
(1) lens per 8' unit
1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings.
MOUNTING DETAILS
1” Grid Mounting Options
9/16” Grid Mounting Options
Screw Slot
Mounting
1” Grid, Standard Tile: 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile:
Screw Slot Grid:
Use G1 or G1G in part # Use G1 or G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or GBG in part # Use GS or GSG in part # Use GS or GSG in part #
INACCESSIBLE CEILING MOUNTING
Flange Detail
Non-Flange
SPECIALTY MOUNTS
Spackle Flange
Exposed Flange Detail:
Metal Pan or Millwork:
Drywall, Flangeless Look:
Specify FL or FLF in part # Specify NF or NFN in part # Specify SF or SFS in part #
MR16 LAMP
Perimeter Mount
Rotating Crossbar
Bracket and Wall Rail:
Specify PM in part #
Unavailable Structure Support:
Specify RC in part #
APPLICATION: MR16’s are ideal for conference rooms,
corridors, wall washing, retail spaces and training facilities where accent lighting is required.
ELECTRICAL: Standard 50 watt max halogen lamp transformer (120v
or 277v), 60 watt max LED electronic transformer (120v or 277v). MR16
installed as independent circuit. MR16 voltage to match LED voltage.
TECHNICAL: MR16 fully enclosed compartment eliminates light from entering into other fixture areas. Available in 20, 35 and 50 watt halogen lamps, up to 12 watt
LED lamps (lamps not included). Consult factory for other lamp types/ wattages.
LABELS: UL and cUL Listed, approved for dry/damp location unless otherwise noted.
®
ORDERING INFORMATION:
MR16 layout guide.
MR16’s should be specified utilizing
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2016 Pinnacle Architectural Lighting®
August 2016
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
GRID RETENTION BRACKET
EDGE EVOLUTION
Joint holes
Joint for
holes
#8-32
for #8-32
ScrewsScrews
GRID RETENTION: At every
joint, the addition of grid
retention brackets results in
a sturdy connection between
the fixtures and the grid.
Insert screws through the
bracket into the grid to
secure.
JOINT ALIGNMENT: Incorporating biscuits and screws
not only creates a secure
joint but also aids in fixture
alignment.
BiscuitBiscuit
®
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2016 Pinnacle Architectural Lighting®
August 2016
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.