EDGE EV3A E V O L U T I O N LED Recessed Linear with Satine Lens Project Name Date Catalog Number Type CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Highly reflective die-formed white painted steel reflector, .125” (3.2mm) white snap-in acrylic lens with matte finish, removable for maintenance. ELECTRICAL Electronic, 120 to 277 volt input and 36V output. 0-10 volt dimming standard. Must specify 1D in circuiting for dimming. LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80. R9≥20, 27K is CRI≥90, 30K, 35K, and 40K is CRI≥82. Minimum lifetime greater than 60,000 hours. MOUNTING Edge is designed to install into acoustical grid and inaccessible ceilings. Specify GXG, FLF, SFS, NFN for individual, unjoinable units (individual units will fall on-grid). Specify GX, FL, SF, NF for continuous runs (runs designed to fall on-grid). Grid retention brackets are integral to housing. Each housing contains 4 grid retention brackets. Consult factory for detailed installation instructions. FINISH Standard powder-coat textured white, metallic silver, textured black, graphite or bronze painted finish, consult factory for chip of standard paint finishes. Contact factory for additional custom color and finish options. WARRANTY Edge LED offered with a 5-year limited warranty. Covers LED, driver and fixture. LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted. YEAR LED WARRANTY Daylight Sensor MR16 Corners LFL Convertible LED 5-1/8” 5-1/8” (130.2mm) LED Convertible YEAR LED WARRANTY LFL 3” (76.2mm) G1/G9/GS: 3-13/16” 3-13/16” (96.8mm) LFL FL & FLF: Convertible 4-1/8” (104.8mm)LED L U M I N A I R E S P E C I F I C AT I O N EV3A- ____- ___’- HOUSING COLOR/LUMENS LENGTH LFL Sample Catalog #: EV3A-30-24’-FL-120-1C-W ___- ___- __- __- ____ VOLTAGE CIRCUITING FINISH OPTIONS YEAR LED WARRANTY MOUNTING1 LFL Individual Units2 2- 2’, 23” (584.2mm) fixture2 3- 3’, 35” (889mm) fixture2 4- 4’, 47” (1193.8mm) fixture2 27K Color Temperature Lumen Options 5- 5’, 59” (1498.6mm) fixture2 27- 27K, 302 lumens/ft (5.2 watts/ft) 6- 6’, 71”YEAR (1803.4mm) fixture2 LED 27HO- 27K, 547 lumens/ft (9.9 watts/ft) WARRANTY 8- 8’, 95” (2413mm) fixture2 Staggered 30K Color Temperature Lumen Options Lamps Continuous Runs3 30- 30K, 368 lumens/ft (5.2 watts/ft) xx’- Specify row length to LED 1’ increments LFL 30HO- 30K, 665 lumens/ft (9.9 watts/ft) EV3A- Edge Evolution 3, Satine Lens LED Convertible Convertible LED 120- 120 V 277- 277 V UNV- UNV (120-277) LED Convertible LFL 1C- Single Circuit 1D- Single Circuit Dimming5 1B- Single Circuit with Battery Pack5,9 1E- Single Circuit with Emergency Circuit Individual Units (CANNOT BE JOINED)2 Acoustical Grid Ceiling14 G1G- 1” (25.4mm) Ceiling Grid Convertible Convertible (Utilize Illuminated [EI] or Non-Illuminated LED LFL 35K Color Temperature Lumen Options G9G- 9/16” (14.3mm) Ceiling Grid [EN] Extension in the Options section to Staggered 35- 35K, 384 lumens/ft (5.2 watts/ft) Lamps specify rows to 1/8” increments) GBG- 9/16” (14.3mm) Ceiling Grid with Bevel Trim Installation 35HO- 35K, Instructions 695 lumens/ft (9.9 watts/ft) GSG- Screw Slot Ceiling Grid Inaccessible Ceiling 40K Color Temperature Lumen Options FLF- Standard5-1/8” 1/2” (127.mm) Flange 40- 40K, 394 lumens/ft (5.2 watts/ft) SFS- Spackle(130.2mm) Flange 40HO- 40K, 713 lumens/ft (9.9 watts/ft) NFN- Flangeless4 Year LED Custom Output Warranty Continuous Runs (JOINABLE)3 CL_____- Specify color temp. and lumens/ft. (i.e. CL35600) Acoustical Grid Ceiling14 CW____- Specify color temp. and wattage/ft. (i.e. CW407.5) G11” (25.4mm) Ceiling Grid 3” (76.2mm) (Specify lumens/watts between standard offering listed above. G9- 9/16” (14.3mm) Ceiling Grid LFL Lumens are specifiedLED per color temp.) G1/G9/GS: Convertible Convertible GB- (96.8mm) 9/16” (14.3mm) Ceiling Grid with Bevel Trim 3-13/16” LED LFL FL & FLF:Screw Slot Ceiling Grid GS(104.8mm) 4-1/8” Inaccessible Ceiling FL- Standard 1/2” (12.7mm) Flange SF- Spackle Flange NF- Flangeless4 W- Matte White S- Metallic Silver BL- Textured Black GR- Graphite BR- Bronze CC- Custom Color QSCPMRFLMRFPMRCEV3CHEV3CIEV3COEI__EN__- Quick Ship12 Chicago Plenum Fixed MR16 Halogen8 Fixed MR16 LED8 Perimeter Mount6 Rotating Crossbar7 90° Horizontal Corner10 90° Inside Corner10 90° Outside Corner10 Factory Installed Illuminated Extension11 Factory Installed NonIlluminated Extension13 See back page for mounting detail. 2Individual units cannot be joined. All end trims are factory installed and cannot be removed in the field. 3Continuous Rows made up of both even and odd length fixtures. Designed to fall on-grid. 4NF and NFN to be utilized for metal pan / millwork ceiling. 5Some Edge configurations will not accommodate all electrical options. Consult factory. 6Available for acoustical grid ceilings. Wall rail painted white unless otherwise specified. 71/2” to 5/8” drywall thickness. Available for standard 1/2” flange (FL). 8Consult MR16 Resource Guide for configurations using MR16 units. 9 Integral battery packs with remote test switch are provided with 1B option. 10See EV3 corner specification sheet for more 5-1/8” information. 11Use “__” to specify desired length. Minimum length is 3”. Sample (130.2mm) part number EV3A-27-24-G1-120-1C-W-EI4 for order a 24’-4” run. 12Includes EV3A, 4 ft individual, unjoinable units, G1G and FLF mounts, universal voltage, std white finish, 1C and 2C circuiting. 13Use “__” to specify desired length. Minimum length is .5”. Sample part number EV3A-27-24-G1-120-1C-W-EN2 for order a 24’-2” run. 14 See page 3 for grid retention bracket details. 1 ® Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Fax 303.322.5568 www.pinnacle-ltg.com Phone 303.322.5570 3” (76.2mm) © 2016 Pinnacle Architectural Lighting® G1/G9/GS: 3-13/16” (96.8mm) August 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com FL & FLF: are the most recent version and supersede all other previously printed or electronic versions. 4-1/8” (104.8mm) P H O T1”O Grid M E Mounting TRY Options Mounting 1119 619 2' E D G E E VScrew O L USlot TION 9/16” Grid Mounting Options EV3C, EV3D 23" (584.2mm) 464 839 310 (1) lens per 2'155 unit 560 59” (1498.6mm) or 60” (1524mm) 5' 280 35" (889mm) (1) lens per 5' unit 71” (1803.4mm) or 72” (1828.8mm) 3' 6' 4' 8' (1) lens per 6' unit lens per 3' unit 1” Grid,(1)Standard Tile: 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: Screw Slot Grid: (1193.8mm) or 48” (2413mm) 96” GS (2438.4mm) Use G1 or47” G1G in part # Use G1 (1219.2mm) or G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or95” GBG in part #or Use or GSG in part # Use GS or GSG in part # (1) lens per 8' unit per 4' unit Test(1)#:lens ILT82918 Test #: ITL82919 Part #: EV3A-40-4’ Part #: EV3A-40HO-4’ 1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings. Lumens per watt: 76 Lumens per watt: 71 Perimeter Mount Flange Detail Non-Flange Spackle Flange Total Delivered Lumens: 1574 Total Delivered Lumens: 2851 Rotating Crossbar EV3A, EV3AL, INDIVIDUAL ANDEV3H CONTINUOUS RUN MODULES 1 59” (1498.6mm) or 60” (1524mm) 23" (584.2mm) 2' 5' (1) lens per 2' unit 35" (889mm) Exposed Flange Detail: Metal Pan or Millwork: Drywall, Flangeless Look: 6' # Specify NF or NFN in part # Specify SF or SFS in part 3'Specify FL or FLF in part # (1) lens per 3' unit (1) lens per 5' unit 71” (1803.4mm) or 72” (1828.8mm) Bracket and Wall Rail: Specify PM in part # (1) lens per 6' unit 47” (1193.8mm) or 48” (1219.2mm) 4' Unavailable Structure Support: Specify RC in part # 95” (2413mm) or 96” (2438.4mm) 8' (1) lens per 4' unit (1) lens per 8' unit 1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings. MOUNTING DETAILS 1” Grid Mounting Options 9/16” Grid Mounting Options Screw Slot Mounting 1” Grid, Standard Tile: 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: Screw Slot Grid: Use G1 or G1G in part # Use G1 or G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or GBG in part # Use GS or GSG in part # Use GS or GSG in part # INACCESSIBLE CEILING MOUNTING Flange Detail Non-Flange SPECIALTY MOUNTS Spackle Flange Exposed Flange Detail: Metal Pan or Millwork: Drywall, Flangeless Look: Specify FL or FLF in part # Specify NF or NFN in part # Specify SF or SFS in part # MR16 LAMP Perimeter Mount Rotating Crossbar Bracket and Wall Rail: Specify PM in part # Unavailable Structure Support: Specify RC in part # APPLICATION: MR16’s are ideal for conference rooms, corridors, wall washing, retail spaces and training facilities where accent lighting is required. ELECTRICAL: Standard 50 watt max halogen lamp transformer (120v or 277v), 60 watt max LED electronic transformer (120v or 277v). MR16 installed as independent circuit. MR16 voltage to match LED voltage. TECHNICAL: MR16 fully enclosed compartment eliminates light from entering into other fixture areas. Available in 20, 35 and 50 watt halogen lamps, up to 12 watt LED lamps (lamps not included). Consult factory for other lamp types/ wattages. LABELS: UL and cUL Listed, approved for dry/damp location unless otherwise noted. ® ORDERING INFORMATION: MR16 layout guide. MR16’s should be specified utilizing Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® August 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. GRID RETENTION BRACKET EDGE EVOLUTION Joint holes Joint for holes #8-32 for #8-32 ScrewsScrews GRID RETENTION: At every joint, the addition of grid retention brackets results in a sturdy connection between the fixtures and the grid. Insert screws through the bracket into the grid to secure. JOINT ALIGNMENT: Incorporating biscuits and screws not only creates a secure joint but also aids in fixture alignment. BiscuitBiscuit ® Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® August 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.