TRANSDUCER CONDITIONING INTERFACE output of this unit provides a direct
Transcription
TRANSDUCER CONDITIONING INTERFACE output of this unit provides a direct
TRANSDUCERS AND MEASUREMENT TRANSMISSIONS BORE GAUGES LINE the sensor to be connected to. In this way the machine downtime is dramatically reduced, thanks to quicker installation and maintenance operations. SENSORS COMPATIBILITY FORKS AND RING GAUGES Both LVDT (full bridge) and HBT(half bridge) sensors can be connected to the TCI 1. The compatibility is also extended to other brands such as Solartron, Tesa, etc. Please specify on the purchase order the transducer model/brand to be connected to the TCI 1, in order to perform an ad-hoc calibration. OUTPUT SIGNAL The TCI 1 is manufactured with two different output signals: • Tension (±5V or ±10V) • Current (4-20mA). BENCH GAUGES POWER SUPPLY The electrical supply is provoded by means of the same connector used for the output signal. The TCI 1 can be ordered both in dual voltage mode (±15V/±12V) and single voltage mode (24V). INDICATORS AND ELECTRONIC DISPLAY UNITS TCI 1 stands for “Transducer Conditioning Interface” at one channel. It has been developed with technical and functional features particularly suitable to convert a position measurement in a signal compatible with most of the analog cards for data acquisition. The output of this unit provides a direct electric signal (tension or current), proportional to the measurement of the sensor at the input stage. The output signal can be fetched by PLC analog cards, in order to control and manage process automations and to be further elaborated by systems such SCADA supervisors. The TCI 1 is a PLUG&PLAY unit. It is delivered specifically calibrated for HOW TO ORDER A MODULE EXAMPLE 6 7 4 6 6 7 4 6 LVDT 1 CHANNEL ±1 mm 24 V MARPOSS CURRENT 4-20 mA T 0 N 0 X 1 A C 1 0 U 2 6 7 4 6 N X A C U 0 1 LVDT HBT 1 CH ±0,5 ±1 ±1,5 ±2,5 ±5 ±1,5 24 V T 0 V / ±12 V MARPOSS MICROCONTROL SOLARTRON MERCER TESA ±5 ±10 4-20 mA 0 1 2 3 4 INTERFACE BOXES FOR DATA ACQUISITION The code to order a TCI 1 is defined by means of the following specification. 1. Transducer type (LVDT o HBT) 2. Measuring Range 3. Power Supply type 4. Compatibility (*) 5. Output type. 0 1 0 1 2 3 4 0 1 2 NOTE. (*) If the transducer type is not included in the list, please contact MARPOSS office to define the specific order code. TCI 1 - 1 SOFTWARES TRANSDUCER CONDITIONING INTERFACE TRANSDUCERS AND MEASUREMENT TRANSMISSIONS TECHNICAL SPECIFICATION MECHANICAL SPECIFICATIONS DESCRIPTION PROTECTION DEGREE (WITH CONNECTORS PLUGGED IN): DIMENSIONS WEIGHT: OPERATING TEMPERATURE: STORING TEMPERATURE: OPERATING RELATIVE HUMIDITY (NOT CONDENSING): STORING RELATIVE HUMIDITY (NOT CONDENSING): BORE GAUGES LINE ELECTRICAL IP52 See Fig. 4 140 gr. 0°... + 50 °C -25°... + 75 °C 20%... 80% 10% ... 95% DESCRIPTION SPECIFICATIONS LINEARITY ERROR: GAIN DRIFT: OFFSET DRIFT: POWER SUPPLY REJECTION RATIO (GAIN+OFFSET): Max 0.05% OF THE END SCALE Max 0.02% / °C OF THE END SCALE Max 0.02% / °C OF THE END SCALE Max 0.04% / V OF THE END SCALE (VOLTAGE: +/-15V) Max 10 mV rms VOLTAGE OUTPOUT Max 20 µA rms CURRENT OUTPOUT Typical 5.1 KHZ Typical 3.3 Vrms Max 30 mA Typical 500 HZ OUTPUT RIPPLE (AF SPIKE EXCLUDED ): FORKS AND RING GAUGES TRANSDUCER FREQUENCY: TRANSDUCER VOLTAGE SUPPLY: TRANSDUCER CURRENT SUPPLY: BANDWIDTH: VOLTAGE SUPPLY DESCRIPTION Dual filtered and stabilised +/- 15 Vdc +/- 5% Max. ripple allowed at 100/120 HZ: 50 mVpp +/- 12 Vdc +/- 5% Max. ripple allowed at 100/120 HZ: 50 mVpp Typical consume with transducer connected: voltage output +/- 20 mA current output +/- 40 mA max Single 24 Vdc +/-10% Max. ripple allowed at 100/120 HZ: 200 mVpp Typical consume with transducer connected: Voltage output 45 mA Current output 65 mA max ±15 V ±12 V (IF CONFIGURED WITH A TENSION OUTPUT SIGNAL) BENCH GAUGES ±24 V OUTPUT SIGNAL DESCRIPTION INDICATORS AND ELECTRONIC DISPLAY UNITS TENSION MODE ±5V ±10V CURRENT MODE 4/20 MA Maximum output current +/-1 mA Maximum output current +/-1 mA Load impedance max. 250 ohm min. 100 ohm DIMENSIONS 38,5 16,6 10,2 121,3 109,5 92,5 3,8 65 29,5 INTERFACE BOXES FOR DATA ACQUISITION The TCI 1 can be fixed by means of four slotted holes. The IP 54 protection degree allows to install the TCI 1 externally from electric switchboards. PROBE CONNECTOR For a full list of address locations, please consult the Marposs official website D6D00401G0 - Edition 09/2007 - Specifications are subject to modifications © Copyright 2007 MARPOSS S.p.A. (Italy) - All rights reserved. SOFTWARES MARPOSS, and Marposs product names/signs mentioned or shown herein are registered trademarks or trademarks of Marposs in the United States and other countries. The rights, if any, of third parties on trademarks or registered trademarks mentioned in the present publication are acknowledged to the respective owners. Marposs has an integrated system to manage the Company quality, the environment and safety, attested by ISO 9001, ISO 14001 and OHSAS 18001 certifications. Marposs has further been qualified EAQF 94 and has obtained the Q1-Award. TCI 1 - 2 DISPLAY CONNECTOR