Document 6525784
Transcription
Document 6525784
AB ADDL ALT ANCH APPROX ARCH BB BLDG BM BO BOT/BTM BP BRG BTW CANT CB CC CIP CJ CL CLR COL CONC CONNX CONSTR CONT CORR CMU DET DIA/DIAM DIM DIST DN DR DWG DWL EA EE EF EJ EL/ELEV ELECT EMB ENGR EQ EQUIP EQUIV ES EXIST EXP EXT EW FAB FD FDN FF FIN FL/FLR FTG GA GALV/GV GC HAS HB HORIZ HSB HSS HT INT JST JT K KO KSF KSI L LB LBS LD LDH LDV LGTH LLBB LLH LLV MATL MAX MB MC MC MCJ MECH MEZZ MFR MIN MISC MTL NIC NOM NTS OC OPNG OPP PB PCC PL PLF PLY PRE-ENG PRE-FAB PRELIM PROJ PSF PSI PT PT PW RAD RB RCP RD REF REINF REQ'D REV RTU RW SECT SCH/SCHED SIM SP/SPC SPECS SQ SS STD ST/STL STRUC SYM ANCHOR BOLTS ADDITIONAL ALTERNATE ANCHOR APPROXIMATE ARCHITECT/ARCHITECTURAL BOND BEAM BUILDING BEAM BOTTOM OF BOTTOM BASE PLATE/BEARING PLATE BEARING BETWEEN CANTILEVER CONCRETE BEAM CONCRETE COLUMN CAST IN PLACE CONSTRUCTION JOINT CENTERLINE CLEAR/CLEARANCE COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CORRUGATED CONCRETE MASONRY UNIT DETAIL DIAMETER DIMENSION DISTANCE DOWN DRAIN DRAWING DOWEL EACH EACH END EACH FACE EXPANSION JOINT ELEVATION ELECTRICAL EMBEDMENT ENGINEER EQUAL EQUIPMENT EQUILAVENT EACH SIDE EXISTING EXPANSION EXTERIOR EACH WAY FABRICATE FLOOR DRAIN FOUNDATION FINISHED FLOOR FINISH(ED) FLOOR FOOTING GAGE/GUAGE GALVANIZED GENERAL CONTRACTOR HEADED ANCHOR STUD HIGH BEAM (MASONRY) HORIZONTAL HIGH STRENGTH BOLTS HOLLOW STEEL SECTION HEIGHT INTERIOR JOIST JOINT KIPS KNOCK OUT KIPS PER SQUARE FOOT KIPS PER SQUARE INCH ANGLE LOW BEAM (MASONRY) POUNDS DEVELOPMENT LENGTH LONG DIMENSION HORIZONTAL LONG DIMENSION VERTICAL LENGTH LONG LEG BACK TO BACK LONG LEG HORIZONTAL LONG LEG VERTICAL MATERIAL MAXIMUM MASONRY BEAM MOMENT CONNECTION MASONRY COLUMN MASONRY CONTROL JOINT MECHANICAL MEZZANINE MANUFACTURE/MANUFACTURERS MINIMUM MISCELLANEOUS METAL NOT IN CONTRACT NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE PARAPET BEAM (MASONRY) PRECAST CONCRETE PLATE PONDS PER LINEAR FOOT PLYWOOD PRE-ENGINEERED PRE-FABRICATED PRELIMINARY PROJECTION POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PRESSURE TREATED POST TENSION(ING) (ED) PANEL WIDTH RADIUS ROOF BEAM (MASONRY) REINFORCED CONCRETE PIPE ROOF DRAIN REFERENCE REINFORCING REQUIRED REVISION ROOF TOP UNIT RETAINING WALL SECTION SCHEDULE SIMILAR SPACE(S) SPECIFICATIONS SQUARE STAINLESS STEEL STANDARD STEEL STRUCTURAL SYMMETRICAL T&B T&G TE THK THRD TB TOC TOM TOS TYP TS UNO UON VERT VIF W WB WC W/ W/O WD WGT WH WP WT WWF @ & TOP AND BOTTOM TONGUE AND GROOVE THICKENED EDGE THICK THREAD(ED) TIE BEAM TOP OF CONCRETE TOP OF MASONRY TOP OF STEEL TYPICAL TUBE STEEL UNLESS NOTED OTHERWISE UNLESS OTHERWISE NOTED VERTICAL VERIFY IN FIELD WIDE FLANGED WALL BEAM (TILT) WALL COLUMN (TILT) WITH WITHOUT WOOD WEIGHT WEEPHOLE WORKING POINT STEEL TEE SECTION WELDED WIRE FABRIC AT AND GENERAL FOUNDATIONS/SITE WORK REINFORCED CONCRETE LIGHT GAUGE FRAMING, TRUSSES & SYSTEMS A. ALL WORK SHALL BE IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE 2009, AS ADOPTED AND SUPPLEMENTED BY LOCAL REGULATIONS. A. FOUNDATION DESIGN IS BASED UPON THE FOLLOWING SOILS REPORT: A. CONCRETE WORK SHALL CONFORM TO ACI-05 SPECIFICATIONS, CODES AND STANDARDS. A. B. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS AT THE SITE AND SHALL NOTIFY THE ARCHITECT/ENGINEER OF DISCREPANCIES BETWEEN THE ACTUAL CONDITIONS AND INFORMATION SHOWN ON THE DRAWINGS BEFORE PROCEEDING WITH WORK. COMPANY NAME : PSI DATE: REPORT DATED 10/25/2011 PROJECT NUMBER: PROJECT NO. 0467457 B. CAST-IN-PLACE CONCRETE, UNLESS OTHERWISE NOTED (U.O.N.): ALL LIGHT GAUGE STEEL FRAMING SHALL CONFORM TO THE "SPECIFICATIONS FOR THE DESIGN OF COLD-FORMED STRUCTURAL STEEL MEMBERS," AISI." B. ALL STUDS SHALL BE EQUAL TO A MINIMUM OF 6-INCH 54 MIL THICK, U.O.N. C. ALL STUDS SHALL BE "C" SHAPE, U.O.N. D. MATERIALS, U.O.N.: 54, 68 AND 97 MIL STUDS 27, 33, AND 43 MIL. STUDS RUNNERS AND ACCESSORIES C. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE COMPLETE DESIGN OF THE STRUCTURE. THEY DO NOT INDICATE THE MEANS AND METHODS OF CONSTRUCTION UNLESS SO STATED OR NOTED. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE WORKERS, OR THER PERSONS DURING CONSTRUCTION. D. OBSERVATION VISITS TO THE SITE BY EOR OR REPRESENTATIVES OF THE EOR MAY BE MADE DURING CONSTRUCTION. ANY SUPPORT SERVICES PERFORMED HEREIN SHALL BE DISTINGUSHED FROM INSPECTION AND.OR TESTING SERVICES PERFORMED BY OTHERS, AND ARE NOT TO BE CONSTRUED AS SUPERVISION AND/OR MANAGEMENT OF CONSTRUCTION. E. THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACING AND SHORING OF ALL STRUCTRUAL MEMBERS AS REQUIRED FOR STABILITY OF THE STRUCTURE DURING ALL PHASES OF CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER OF ANY CONDITION WHICH, IN HIS OPINION, MIGHT ENDANGER THE STAILITY OF THE STRUCTURE OR CAUSE DISTRESS WITHIN THE STRUCTURE. F. CONSTRUCTION MATERIALS SHALL NOT BE STACKED ON FLOORS OR ROOFS IN EXCESS OF THE DESIGN LIVE LOADS WHICH ARE INDICATED IN THE GENERAL NOTES. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE SUBCONTRACTORS ARE INFORMED AND DO NOT VIOLATE THIS IMPORTANT REQUIREMENT. IMPACT SHALL BE AVOIDED WHEN PLACING MATERIALS ON FLOORS OR ROOFS. G. DRAWINGS ARE NOT TO BE SCALED. H. FOR ACTUAL ELEVATION ON FIRST FLOOR (REF. ELEV. 0'-0" HEREIN), SEE SITE PLAN. I. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO THE DETAILS PRESENTED, SIMILAR DETAILS SHALL BE USED SUBJECT TO THE REVIEW OF ENGINEER OF RECORD. J. SUBMIT WRITTEN REQUEST TO THE ARCHITECT FOR APPROVAL OF ANY PROPOSED CHANGE TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. SPLICING, CUTTING, NOTCHING OR OTHER ALTERATIONS TO STRUCTURAL MEMBERS ARE NOT PERMITTED WITHOUT WRITTEN AUTHORIZATION OF THE ENGINEER. ANY UNAUTHORIZED DEVIATION FROM THE CONTRAC T DOCUMENTS, AND CORRECTION THEREOF, IS THE RESPONSIBILITY OF THE CONTRACTOR. SUBSEQUENT DOCUMENTATION/REQUESTS TO BUILDING ENGINEERING OF RECORD FROM GC SHALL INCLUDE EVALUATION OF DEVIATIONS BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF THE PROJECT. B. C. D. ALLOWABLE SOIL PRESSURE IS TO BE 3000 PSF. ANY FILL REQUIRED TO BACKFILL EXCAVATED AREA OR ACHIEVE FINISHED GRADE IN STRUCTURAL AREAS SHALL BE AS INDICATED BY GEOTECHNICAL ENGINEER. THE FILL SHALL BE PLACED IN LEVEL LIFTS NOT EXCEED 12 INCHES LOOSE THICKNESS AND COMPACTED TO A MINIUM OF 95% OF THE SOIL'S MODIFIED PROCTOR MAXIMUM DRY DENSITY AS DETERMINED BY ASTM SPECIFICATION D-1557. IN-PLACE DENSITY TESTS SHALL BE PERFORMED BY AN EXPERIENCED ENGINEERING TECHNICIAN.TESTS SHALL BE PERFORMED FOR EACH 2,000 SQUARE FEET, IN EVERY COLUMN FOOTING LOCATION AND EACH 50 FEET ALONG WALL FOOTINGS. COPIES HE TEST REPORTS SHALL BE FURNISHED TO THE STRUCTURAL ENGINEER. E. REMOVE FREE WATER FROM EXCAVATIONS BEFORE PLACING CONCRETE. F. CAUTION SHOULD BE USED WHEN OPERATING VIBRATORY COMPACTING EQUIPMENT NEAR THE EXISTING STRUCTURE TO AVOID THE RISK OF DAMAGE TO THE STRUCTURE. G. REFER TO ARCHITECTURE DRAWINGS FOR ANY NECESSARY WATERPROOFING REQUIREMENTS. B. C. BELOW GRADE, MORTAR SHALL BE TYPE M. ABOVE GRADE, M OR S. GROUT TO CONFORM TO ASTM C270. 4. AT CHANGES IN DIRECTION OF CONCRETE WALLS, BEAMS, AND FOOTINGS, PROVIDE CORNER BARS OF SAME SIZE, QUANTITY AND SPACING AS HORIZONTAL STEEL. STEEL JOISTS AND STEEL GIRDERS GROUT FOR FILLED CELLS SHALL CONFORM TO ASTM C476, AND SHALL HAVE A SLUMP OF BETWEEN 8" AND 10". GROUT COMPRESSIVE STRENGTH SHALL BE 3000 PSI AT 28 DAYS. 4"X4" MINIMUM CLEANOUTS REQUIRED FOR GROUT POURS EXCEEDING 4'. 5. LAP SPLICES SHALL BE 48 BAR DIAMETERS, WIRED TOGETHER. A. ALL STEEL JOISTS, JOIST GIRDERS AND ASSOCIATED PARTS SHALL CONFORM TO THE STANDARDS OF THE STEEL JOIST INSTITUTE. B. ALL JOISTS AND GIRDERS SHOWN IN THE PLANS ARE MINIMUM SIZES. DEPTH CANNOT BE DECREASED OR INCREASED WITHOUT WRITTEN APPROVAL BY ARCHITECT/ENGINEER. C. CONTRACTOR TO FOLLOW SJI REQUIREMENTS AS A MINIMUM. THERE SHALL BE NO HORIZONTAL JOINTS IN ANY CONCRETE POURS UNLESS SHOWN ON THE STRUCTURAL DRAWINGS. THE ENGINEER OF RECORD SHALL APPROVE ALL DEVIATIONS OR ADDITIONAL JOINTS IN WRITING. D. PROVIDE BRIDGING AND X-BRACING AS PER THE REQUIREMENTS OF SJI. SHOULD PLANS INDICATE BRIDGING AND X-BRACING IN EXCESS OF THAT REQUIRED BY SJI, PLANS WILL GOVERN. G. SAW CUT CONTROL JOINTS SHALL BE LOCATED @ 15' O.C. MAXIMUM, U.O.N. WITH LENGTH TO WIDTH RATIO NOT TO EXCEED 2:1. REFER TO SUBMITTAL REQUIREMENTS REGARDING COORDINATION OF CONSTRUCTION JOINTS. REFER TO PLANS FOR EXPANSION JOINT LOCATIONS. E. PROVIDE SEATS, HEADER CHORD EXTENTIONS, OR OTHER ELEMENTS AND FEATURES SHOWN IN THE CONTRACT DOCUMENTS AND THOSE WHICH ARE REQUIRED FOR PROPER ERECTION AND PERFORMANCE OF STEEL JOISTS. H. ALL EPOXY ANCHORS USED AT REINFORCED CONCRETE SHALL BE HILTI HVA OR SIMPSON SET, ET, OR AT., U.O.N. F. STEEL JOISTS, JOIST GIRDERS, BRIDGING AND X-BRACING SHALL BE DESIGNED FOR NET UPLIFT. LOAD COMBINATIONS SHALL CONFORM TO THE CODES SPECIFIED IN THE PROJECT DOCUMENTS. I. POWDER ACTUATED FASTNERS (PAFS) NOT PERMITTED AT CONCRETE. D. E. MASONRY CONTROL JOINTS SHALL BE LOCATED AT 26'-0" O.C. FOR EXTERIOR WALLS AND 32'-0" O.C. FOR INTERIOR WALLS, U.O.N., TIE BEAM / BOND BEAM REINF. SHALL BE CONT. G. PROVIDE 8" DEEP PRECAST REINFORCED CONCRETE LINTELS OVER ALL MASONRY OPENINGS NOT SHOWN TO HAVE A STRUCTURAL BEAM. MINIMUM END BEARING SHALL BE 8". LINTEL WIDTH TO MATCH MASONRY WIDTH. C. 4. LAP SPLICES SHALL BE AS FOLLOWS: MINIMUM LAP SPLICE LENGTHS 3. SUBMITTAL REQUIREMENTS: SHOP DRAWINGS/DATA TO BE SUBMITTED FOR APPROVAL. SUBMITTALS SHALL BE SIGNED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER LISCENCED IN THE STATE OF THE PROJECT A. B. #5 30" #6 36" #7 42" ALL STRUCTURAL STEEL WORK SHALL CONFORM TO AISC SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS-ALLOWABLE STRESS DESIGN, 13TH ED. REF. PLANS FOR CONCENTRATED LOADS AND/OR UNUSUAL LOAD PATTERNS. H. AT A MINIMUM, PROVIDE BOTTOM CHORD BRACING EVERY OTHER JOIST AT SUPPORTING W BEAMS. PROVIDE ADDITIONAL BRACING AS SPECIFIED HEREIN AS TYPICAL AND AS INDICATED IN PLANS. I. MINIMUM WELDS, U.O.N.: 1. BAR JOIST ENDS 2. JOIST GIRDER ENDS MATERIAL SHALL CONFORM TO THE FOLLOWING, EXCEPT AS NOTED: W BEAMS STRUCTURAL STEEL PLATED AND SHAPES THREADED ROD ANCHOR BOLTS OTHER ANCHOR BOLTS PIPE SECTIONS TUBE SECTIONS C. G. ASTM A992 ASTM A36 ASTM F1554 GRADE 36 ASTM A307 ASTM A53, GRADE B. ASTM A500, GRADE B. WELDING, UNLESS OTHERWISE NOTED (U.O.N.): 1. ALL SHOP AND FIELD WELDING SHALL CONFORM TO AWS STRUCTURAL WELDING CODE, ANSI/AWS D1.1 D. CONNECTIONS, UNLESS OTHER WISE NOTED (U.O.N.): DECK SHALL CONFORM TO SDI SPECIFICATIONS. B. SPECIFICATION AND FASTENING REQUIREMENTS, REF. PLANS C. WELD METAL SHALL PENETRATE ALL LAYERS OF DECK MATERIAL. END LAPS AND SIDE JOINTS SHALL BE COMPLETELY FUSED TO THE SUPPORTING MEMBERS. USE PROPER SIZE WELDING ELECTRODE AND WELDING MACHINE CURRENT, SO THAT WELDS ARE GOOD PENETRATION AND FREE FROM "BURN-THROUGH". D. METAL DECK SHALL BE ERECTED CONTINUOUS FOR A MINIMUM OF THREE (3) SPANS AND SHALL LAP AT THE CENTERLINE OF SUPPORTS A MINIMUM OF TWO (2") INCHES. PROVIDE A MINIMUM END BEARING OF 2" OVER SUPPORTS. E. PROVIDE SUPPORTS FOR METAL DECK AS REQUIRED WHERE METAL DECK IS CUT OUT. WELD DECK TO SUPPORTS SAME AS EDGE CONDITION. DO NOT HANG OR ATTACH DUCTWORK, CONDUIT, PIPING, EQUIPMENT, CEILINGS, ETC. FROM METAL DECKING. 6. ALL WALL DOWELS SHALL MATCH REINFORCING SIZE AND QTY. L. POWDER ACTUATED FASTENERS (PAFS) NOT PERMITTED AT MASONRY 2. FIELD CONNECTIONS SHALL BE MADE WITH 3/4" DIA. MIN. HIGH-STRENGTH BEARING TYPE BOLTS (A325N) WITH THREADS ASSUMED TO BE INCLUDED IN SHEAR PLANES. F. M. ALL MASONRY LOCATED BELOW GRADE SHALL BE GROUTED SOLID. 3. CONNECTIONS NOT FULLY DETAILED IN PLANS SHALL BE DESIGNED BY CONTRACTOR ACCORDING TO AISC STANDARDS. IF FORCES ARE NOT PRESENTED IN PLAN OR DIRECTLY IMPLIED THEREIN, CONNECTIONS SHALL BE BASED ON THE FULL CAPACITY OF THE SECTION (S)-EXCEPT THAT STEEL CONNECTIONS FOR BEAMS SIMPLY SUPPORTED AND UNIFORMLY LOADED MAY BE BASED ON 55% OF THE AISC UNIFORM LOAD CARRYING CAPACITY OF THE BEAMS. G. STRUCTURAL INSPECTION A. B. THE OWNER SHALL EMPLOY A QUALIFIED INDEPENDENT INSPECTION AGENCY. THIS AGENY (REFERRED TO AS INSPECTOR HEREIN) SHALL BE RESPONSIBLE FOR VERIFYING THAT PROJECT STRUCTURAL WORK IS ACCOMPLISHED IN CONFORMANCE WITH THE CONTACT DOCUMENTS. DURATION AND FREQUENCY OF JOB VISITS SHALL BE SUFFICIENT FOR THE INSPECTOR TO STATE AT THE COMPLETION OF THE PROJECT THAT THE STRUCTURAL WORK IS ACCOMPLISHED, AND ITS RELATED ELEMENTS HAVE BEEN ERECTED IN ACCORDANCE WITH THE CONTACT DOCUMENTS. SPECIFIC SYSTEMS TO BE INSPECTED INCLUDE: FOUNDATION CONCRETE (COLUMNS/BEAMS) CONCRETE (GENERAL, SLAB ON GRADE) MASONRY STRUCTURAL STEEL (INCLUDING BAR JOISTS) METAL DECK WOOD PLANK DECKING LIGHT GAUGE FRAMING C. D. THE FOREGOING LIST IS NOT INTENDED TO BE ALL INCLUSIVE. THE INSPECTOR SHALL USE HIS PROFESSIONAL JUDGEMENT AND HIS KNOWLEDGE OF THE JOB SITE CONDITIONS AND THE OFFICIAL CONTRACT DOCUMENTS. THE INSPECTOR WILL NOT REPLACE THE QUALITY CONTROL PERSONNEL OF THE CONTRACTOR. ALL INSPECTION REPORTS SHALL BE FORWARD BY THE INSPECTOR TO THE ENGINEER AND ARCHITECT OF RECORD. 3 3 3 1 Brett C. Rylands P.E. 31322 1 3/16" FILLET, 2" LONG, EACH SIDE 1/4" FILLET, 3" LONG, EACH SIDE A. 2. ALL WELDING IN THE SHOP AND IN THE FIELD SHALL BE PERFORMED BY CERTIFIED WELDERS ONLY. 3. WELDING ELECTRODES SHALL BE E70XX LOW HYDROGEN. Pressures STEEL DECK NOTES 1. TIGHTEN BOLTS BY THE "SNUG-TIGHT" METHOD. SHOPDRAWINGS/DATA TO BE SUBMITTED FOR APPROVAL CONSTRUCTION JOINT LOCATIONS IN STRUCTURAL SLABS WALL/VENEER CONTROL JOINT LOCATIONS CONCRETE MIX DESIGNS (INDICATE INTENDED USE OF EACH) REINFORCING STEEL STRUCTURAL STEEL (INCLUDING JOISTS) METAL DECK WOOD DECK LIGHT GAUGE FRAMING SPLICE LENGTHS 5. ALL REINFORCING HOOKS AND BENDS SHALL BE STANDARD ACI TYPE. SHOP DRAWINGS SHALL BE "APPROVED", SIGNED AND DATED BY THE GENERAL CONTRACTOR PRIOR TO SUBMITTAL TO ENGINEER AND ARCHITECT OF RECORD. SHOP DRAWINGS SHALL NOT CONTAIN REPRODUCTIONS OF THE CONTRACT DRAWINGS. BAR SIZE OWNER SHALL EMPLOY A QUALIFIED TESTING LABORATORY TO PREPARE ONE SET OFFOUR TEST CYLINDERS PER DAY OR ONE SET FOR EACH 50 CUBIC YARDS POURED, MAXIMUM. LABORATORY REPORT SHALL BE FURNISHED TO THE STRUCTURAL ENGINEER SHOWING STRENGTH OF CONCRETE AT 7 (1 CYLINDER) AND 28 (2 CYLINDERS) DAYS. FINAL CYLINDER SHALL BE HELD IN RESERVE. STRUCTURAL STEEL 3. BOND BEAM AT TOP OF WALL SINGLE COURSE K.O. / LINTEL BLOCK WITH (1) #5 CONT. BAR EACH COURSE. 1.0 II B C ORDINARY STEEL W/ CONCENTRIC BRACE FRAME 3.25 0.096 0.295 0.095 0.236 0.107 STATIC EQUIVALENT 39K (STRENGTH LEVEL) 2. F. 2. ALL OPENINGS IN CMU SHALL BE REINFORCED WITH AT LEAST (1) #5 BAR AT THE TOP, BOTTOM AND BOTH SIDES OF THE OPENING SUBMITTALS SHALL CONFORM TO THE REQUIREMENTS OF THE CONTRACT DRAWINGS (REFERENCE ITEM C ABOVE FOR EXCEPTION). NON-CONFORMING OR NON-REVIEWED SUBMITTALS WILL BE RETURNED WITHOUT REVIEW. 1. REINFORCING, UNLESS OTHERWISE NOTED (U.O.N.) IN PLANS: 1. REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60. 90 MPH (ASCE 7-05) 1.00 II ENCLOSED C +/- 0.18 ANY CHANGES TO THE DESIGN CONCEPT SHOWN IN CONTRACT DOCUMENTS SHALL BE SUBMITTED IN WRITING AND APPROVED BY THE ARCHITECT AND ENGINEER PRIOR TO SUBMITTING SHOP DRAWINGS. ALL SUCH CHANGES SHALL BE "BUBBLED" ON THE SHOP DRAWINGS AND REFERENCED TO THE PROPER R.F.I. D. K. E. PLACE ALL MASONRY IN RUNNING BOND WITH 3/8" MORTAR JOINTS. PROVIDE COMPLETE COVERAGE FACE SHELL MORTAR BEDDING, HORIZONTAL AND VERTICAL. PROVIDE FULL MORTAR WEBS IN ALL COURSE OF GROUTED CELLS AND CELLS ADJACENT TO GROUTED CELLS. F. 20 PSF MAX. (10 PSF TO BE USED FOR APPROVAL OF SHOP DRAWINGS DOES NOT INDICATE ACCEPTANCE OF DEVIATIONS FROM CONTRACT DOCUMENTS OR PREVIOUS SHOP DRAWING REVIEW, UNLESS SPECIFICALLY NOTED THEREIN BY ENGINEER OF RECORD. ALL CONNECTIONS SHALL BE (4) #10-12 TEK SCREWS AS A MINIMUM, U.O.N. OR AS REQUIRED BY MANUFACTURER AND APPROVED BY STRUCTURAL ENGINEER. ALL PROPOSED ALTERNATE CONNECTION CLIPS SHALL BE SUBMITTED TO BUILDING ENGINEER FOR REVIEW. SUBMITTAL SHALL INCLUDE APPLICABLE LOAD TABLES FOR CLIPS. WHEREVER LARGER WIDTH CMU BASE COURSES BECOME SMALL WIDTH CMU ABOVE, A SINGLE COURSE BOND BEAM MUST BE PROVIDED. THIS BOND BEAM SHALL BE K.O. / LINTEL BLOCK WITH (2) #5 CONT., UNLESS OTHERWISE NOTED IN PLANS. SHOP DRAWING REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT. CORRECTIONS OR COMMENTS MADE ON THIS REVIEW DO NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR ERROSRS AND OMMISIONS, AND FROM COMPLIANCE WITH THE PLANS AND SPECIFICATIONS. CORRECTIONS OR COMMENTS DO NOT AUTHORIZE AN INCREASE IN THE CONSTRUCTION BUDGET. 1. REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60. I. J. A. G. ARCHITECTS PROJECT #: 2110572 WIND PRESSURES & VELOCITIES GIVEN ARE NOMINAL (V nom) REINFORCING, UNLESS OTHERWISE NOTED (U.O.N.): 3. WHERE CONTINUOUS REINFORCING IS SPECIFIED, SUCH REINFORCING MAY BE SPLICED WHERE APPROVED IN WRITTING BY THE ENGINEER OF RECORS. DESIGN DATA SUBMITTALS ALL PARTS AND ACCESSORIES SHALL BE FORMED FROM STEEL HAVING A G-60 GALVANIZED COATING MEETING THE REQUIREMENTS OF ASTM A525 / ASTM A653. CONCRETE BLOCK SHALL CONFORM TO ASTM C90, TYPE II, WITH A MIN. NET COMPRESSIVE STRENGTH AT 28-DAYS OF 1900 PSI (F'M = 1500 PSI). NORMAL WEIGHT UNITS U.O.N. ALL EMBED PLATES SHALL OCCUR AT GROUTED, REINFORCED CELLS WITH FACE SHELLS REMOVED. SEISMIC DESIGN: IMPORTANCE: OCUPANCY CATEGORY: DESIGN CATEGORY: SITE CLASS: BASIC S-R SYSTEM: R (RESPONSE MOD.): Cs (RESPONSE COEF.): Ss: S1: Sds: Sd1: ANALYSIS PROCEDURE: DESIGN BASE SHEAR: F. B. I. WIND DESIGN: VELOCITY: IMPORTANCE: OCUPANCY CATEGORY: ENCLOSURE CATEGORY: WIND EXPOSURE: INTERNAL PRESSURE COEFF: +/- PROVIDE MANUFACTUERS STANDARD STEEL RUNNERS, BRIDGING, BLOCKING, LINTELS, CLIP ANGLES, BRACING, REINFORCEMENTS, FASTENERS, ETC. AS REQUIRED TO PROVIDE A COMPLETE STEEL FRAMING SYSTEM CAPABLE OF ACCOMMODATING THE LOADS PRESENTED IN THE CONSTRUCTION DOCUMENTS. SPLICES IN STUDS SHALL NOT BE PERMITTED. ALL EPOXY ANCHORS USED IN MASONRY SHALL OCCUR AT GROUTED, REINFORCED CELLS AND BE HILTI HIT-HY150. Pg =5 PSF Pf = 10 PSF (RAIN & SNOW) D. E. H. H. ROOF SNOW LOADS FOOTINGS 3" SLABS, COLUMNS AND BEAMS EXPOSED TO EARTH OR WHEATHER 2" (#6 TO #18 BARS), 1 1/2" (3# TO #5 BARS) SLABS NOT EXPOSED TO EARTH OR WHEATHER 3/4" (#3 TO #11 BARS) BEAMS AND COLUMNS NOT EXPOSED TO EARTH OR WHEATHER 1 1/2" (#3 TO #18 BARS) 2. WELDED WIRE FABRIC SHALL CONFORM TO ASTMA185. WIRE FABRIC SHALL BE CONTINUOUS, LAPPED ONE CROSS WIRE SPACING PLUS 2" MINIMUM. THE DESIGN OF THE STRUCTURE INCLUDE ALLOWANCE FOR A FIRE PROTECTION SYSTEM WITH PIPES UP TO 3” NOMINAL DIAMETER LOCATED AS NECESSARY. LARGER MAINS, IF APPLICABLE, SHALL BE PRESENTED TO THE STRUCTURAL EOR IN SHOP DRAWINGS. LARGER MAINS MAY REQUIRE MORE SPECIFIC COORDINATION WHERE HUNG FROM STRUCTURE. UPLIFT) CONCRETE COVER OVER REINFORCEMENT: ALL MASONRY WORK SHALL CONFORM TO ACI SPECS FOR MASONRY STRUCTURES (ACI 530.1-05). L. 20 PSF C. 50 KSI 33 KSI 33 KSI A. THE MOST STRINGENT REQUIREMENTS APPLY IN CASE OF CONFLICT BETWEEN SPECIFICATIONS, STANDARDS, CODES AND DRAWINGS. ROOF LIVE LOADS ROOF DEAD LOADS U.O.N. 3000 PSI 28-DAY COMPRESSIVE STRENGTH, NORMAL WEIGHT, MAXIMUM AGGREGATE SIZE OF 1", 0.55 MAX. W/C, AIR CONTENT 6% - 8% FOR CONCRETE EXPOSED TO WEATHER CONCRETE MASONRY UNITS (CMU) K. M. PORTLAND CEMENT PER ASTM C150 PROPORTIONED FOR MAX. ALLOWABLE UNIT SHRINKAGE OF 0.03% ALL ROOF AREAS, DESIGN FOR ZONE 3 PRESSURES U.O.N. ABOVE Wind Zones - Plan FLORIDA SE INC. 1000 DARDEN CENTER DRIVE ORLANDO, FL 32837 LIST OF STRUCTURAL ABREVIATIONS ALL SIDES, DESIGN FOR ZONE 5 PRESSURES U.O.N. ABOVE PROVIDE STL. SHIMS AND EMBEDS AS REQUIRED TO SUPPORT DECK ON "TYPICAL" BAY SPACING. Wind Zones - Elevation 4. CONNECTIONS SHALL BE DOUBLE ANGLE OR STANDARD SHEAR TAB TYPE U.O.N. SINGLE ANGLE AND EXTENDED SHEAR TAB CONNECTIONS SHALL NOT BE PERMITTED UNLESS SPECIFICALLY DETAILED AS SUCH HEREIN. E. SHOP DRAWINGS (SEE SUBMITTALS) SHALL INCLUDE COMPLETE DETAILING OF STRUCTURAL STEEL MEMBERS AND CONNECTIONS AS REQUIRED TO FABRICATE AND ERECT ALL STRUCTURAL STEEL FRAMING. F. GROUT UNDER BEARING PLATES SHALL BE NON-METALLIC, NON-SHRINK TYPE WITH A COMPRESSIVE STRENGTH OF AT LEAST 6000 PSI WHEN BEARING ON 3000 PSI CONCRETE, AND 8000 PSI WHEN BEARING ON 4000 PSI CONCRETE. G. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIP GALVANIZED OR OTHERWISE PROTECTED. H. ALL STEEL EXPOSED TO SOIL SHALL BE ENCASED IN CONCRETE OR OTHERWISE PROTECTED. C A 50% Owner Review: 95% Owner Review: Permit Issue Date: Bid Set Issue: 22 03/26/12 REVISION INFORMATION C B B ALUMINUM STOREFRONT SYSTEMS, CANOPIES, AWNINGS AND MARQUEES E. PROVIDE COPIES OF MANUFACTURERS LITERATURE FOR ALL MATERIALS AND PRODUCTS USED IN CONSTRUCTION ON THE PROJECT. "A" 10 PSF OVERALL, + 10 PSF DRIFT AT TOWER. (5 FT. LONG TRIANGULAR DISTRIBUTION) "B" 10 PSF OVERALL, INCLUDES DRIFT, GOVERNS OVER UNBALANCED LOADING "C" 20 PSF OVERALL, INCLUDES DRIFT, GOVERNS OVER UNBALANCED LOADING, TYP. U.O.N. Restaurant #: 10X0002 NOTE: SNOW LOADS FOR JOIST DESIGN HAVE BEEN SIMPLIFIED DUE TO LARGE NUMBER OF PROJECTIONS AND CONGESTED POSITION OF PROJECTIONS New Stand Alone P89 Snow Zones - Plan 245 SUMMIT BLVD BIRMINGHAM, AL 35209 Drawn By: Checked By: DB RA BIRMINGHAM, AL Drawing Title: General Notes and Typical Details S1.1