TransFix/EDTA Cerebrospinal Fluid (CSF)
Transcription
TransFix/EDTA Cerebrospinal Fluid (CSF)
Cellular Antigen Stabilising Reagent TransFix/EDTA Cerebrospinal Fluid (CSF) Sample Storage Tubes Instructions for Use Version: 02, 05/2013 Product Description TransFix® is a patented stabilisation solution that prevents cellular degradation in cerebrospinal fluid (CSF) for analytical testing purposes. TransFix/EDTA CSF Sample Storage Tubes consist of 5ml tubes containing 0.2ml of TransFix/EDTA. Principle and Intended Use of TransFix/EDTA CSF Sample Storage Tubes The active components of TransFix stabilise leukocytes and leukocytic antigens for up to 10 days. Using these tubes to stabilise CSF leukocytes it is possible to determine cell subsets via flow cytometric analysis, up to 10 days after collection. Refer to reference for a detailed explanation of how to conduct the flow cytometric analysis (available on www.cytomark.co.uk). Procedure 1. On receipt of the CSF specimen, record the volume of the sample and immediately transfer to the TransFix/EDTA CSF Sample Storage Tube. N.B. CSF samples should be transferred into TransFix/EDTA CSF Sample Storage Tubes immediately after lumbar puncture, but failing this, CSF must be less than 2 hours old when it is treated with TransFix/EDTA. Do not refrigerate the sample before treatment with TransFix/EDTA. 2. 3. 4. 5. 6. 7. 8. Mix gently by inversion at least 10 times and store at 2-8°C for up to 10 days. Allow the stabilised CSF sample to return to room temperature (18-25°C) before preparing it for flow cytometric analysis. Add 2ml of sterile filtered phosphate buffered saline (PBS), pH 7.4 to the stabilised CSF sample and mix gently as before. Centrifuge the sample at 540g for 5 minutes at room temperature. Remove the supernatant and discard. Re-suspend the cell pellet with 300µl of sterile filtered PBS, pH 7.4. Examine the sample e.g. using flow cytometry evaluation. N.B. The dilution factor – depending on the volume of CSF sample - must be accounted for when cell counts from stabilised CSF samples are recorded. N.B. Cross linking of proteins may occur when using TransFix/EDTA. We therefore recommend that all antibody conjugates are validated in association with TransFix/EDTA prior to routine use. Samples of TransFix/EDTA CSF Sample Storage Tubes are available on request. Version: 02, 05/2013 Ordering Information Product Code TF-CSF-5-2 TF-CSF-5-10 TF-CSF-5-25 TF-CSF-5-50 Product TransFix/EDTA CSF Sample Storage Tubes TransFix/EDTA CSF Sample Storage Tubes TransFix/EDTA CSF Sample Storage Tubes TransFix/EDTA CSF Sample Storage Tubes (2 x 5ml tubes) (10 x 5ml tubes) (25 x 5ml tubes) (50 x 5ml tubes) Quantity 2 tubes 10 tubes 25 tubes 50 tubes Storage Conditions and Stability TransFix/EDTA CSF Sample Storage Tubes must be stored at 2-8°C, but must not be frozen and have a shelf life of one year from the date of manufacture or until the expiration date on the label. A certificate of analysis can be provided with every TransFix/EDTA CSF Sample Storage Tube product. Reference Sandra Quijano et al, Journal of Clinical Oncology, Vol. 27, March 2009, 1462-1467 Identification of Leptomeningeal Disease in Aggressive B-Cell Non-Hodgkins Lymphoma: Improved sensitivity of Flow Cytometry Warning Statements 1. TransFix/EDTA CSF Sample Storage Tubes are for research use only. 2. Do not use the TransFix/EDTA CSF Sample Storage Tubes beyond the expiration date on the box and tubes. 3. Incubation times or temperatures other than those specified may give erroneous results. 4. TransFix/EDTA is a clear green liquid. Do not use the TransFix/EDTA CSF Sample Storage Tubes if there is a change in the physical appearance of the liquid as this may indicate deterioration and will affect test results. 5. TransFix/EDTA treated specimens and all materials coming into contact with them should be handled as if capable of transferring infection and disposed of with the proper precautions. 6. Avoid contact of TransFix/EDTA and TransFix/EDTA treated samples with the skin and mucous membranes. Any contact should be washed off with cold water immediately. 7. TransFix/EDTA does not contain any antimicrobial reagents. Microbial contamination should be avoided or erroneous results may occur. Cytomark is a division of Caltag Medsystems Ltd, a company registered in the UK, company number 4162330. Caltag Medsystems Ltd Whiteleaf Business Centre 11 Little Balmer Buckingham MK18 1TF UK Tel: +44 (0) 1280 827460 Fax: +44 (0) 1280 827466 Email: cytomark@caltagmedsystems.co.uk www.cytomark.co.uk Version: 02, 05/2013 Lot Reference No. de. cat. Referencia Codice Κωδικός Αριθμός Nr Katalogow y Kόd Recherche uniquement La investigación sólo utilizan Uso da pesquisa somente Utilizzare solo la ricerca Έρευνα χρησιμοποιούν μόνο Badania używać tylko Výzkum používejte pouze F ES PT I GR PL CZ Αριομός Πορτίδος Kat. Nr. Forschung verwenden Sie nur D Šarže Lotto N⁰ N⁰ de lot N⁰ lot N⁰ de lot Ch-B Lot Cat. No. Research use only GB Lot Code No. Research use only US Language Version: 02, 05/2013 Expirace Termin Waznosci Ημερομπνίο Αήεής Sceadenza Validade Caducidad Date de peremption Verw. bis Exp. Date Exp. Date Skladováni Przechowywa nie Αττοθήκενοη Conservare Armazenar Almacenaje Stockage Lagerung Storage Store Zdravi Skodilivy Szdodliwy Εττίκίνδυνο Nocivo Prejudicial Dañino Dangereux Schädlich Harmful Harmful Nepoužívejte opakovaně Nie używać ponownie Μην ξαναχρησιμο ποιήσετε Non riutilizzare Não reutilize Nahlednete do navodu k pouziti Odwolaj sie do instrukcji obstugi Výrobce Producent Κατασκευασ τής Fabbricante Vedere le istruzioni per l’uso Συμβουλευτείτε τίς oδηγίες xρήσης Fabricante Fabricante Consulte instruçŏes de utilizaçäo Consultar las instrucciones de uso Fabricant Suivre les instructions d’utilisation Ne pas réutiliser No vuelva a usar Hersteller Manufacturer Manufacturer Beachten Sie die Gebrauchsanleitung Consult Instructions for use Consult Instructions for use Nicht wiederverwen den Do not reuse Do not reuse