Electrically heated gas sample probe series SP Version SP2020-H(220)/C/I/BB and SP2020-H(220)/C/I/BB/F
Transcription
Electrically heated gas sample probe series SP Version SP2020-H(220)/C/I/BB and SP2020-H(220)/C/I/BB/F
2 Electrically heated gas sample probe series SP® Version SP2020-H(220)/C/I/BB and SP2020-H(220)/C/I/BB/F SP 2020-H Heated sample probe with integrated valves for: Description • Calibration gas injection The M&C probe SP2020-H(220)/C/I/BB and /BB/F is based on the standard probe SP2000-H. • Probe outlet isolation • Calibration gas will be injected into the probe through a check valve /C directly to the sample outlet. No calibration gas is lost into the stack. • An isolation valve /I shuts off the sample outlet from the internal filter area. • Through a high flow rate check valve /BB, which is fixed to the internal probe area, blow back of the filter housing area and the insitu probe tube will be done. • Through a high flow rate check valve /BB/F, which is fixed to the filter housing wall, blow back of the incorporated ceramic filter will be done incl. the filter area and the insitu probe tube. • Blow back 1/2 2-1.1.6.1 © M&C 09.96 / 06.01 Technical details are subject to change. Copying, including extracts, not permitted unless authorized by M&C. M&C Products Analysentechnik GmbH • Rehhecke 79 • 40885 Ratingen • Germany • Tel.: +49 (0) 21 02 / 9 35-0 • Fax: / 9 35-111 • E-mail: info@muc-products.de • www.muc-products.de 2 Dimensions SP2020-H/C/I/BB Tube 3/8" o.d. SP2020-H/C/I/BB/F Tube 3/8" o.d. Check valve 1/4"NPT Check valve 1/4"NPT Isolation valve Flange 3" 150lbs RF Check valve Isolation valve Flange 3" 150lbs RF 1/8"NPT 1/8"NPT Tube 1/4" o.d. Tube 1/4" o.d. Cal.-gas in Sample out Blow back in Control in (P 1-6bar) (P >0,7bar) (P 3-10bar) Cal.-gas in Sample out Blow back in Control in (P 1-6bar) (P 3-10bar) (P >0,7bar) Dimensions in mm Following options are included: Flange Power Calibration gas connection Blow back gas connection Operating temperature max. 220 °C Calibration gas injection valve Isolation valve Valve for blow back of the filter housing area Valve for blow back of the incorporated ceramic filter Technical specifications Part Number Operating temperature Power supply Calibration gas valve /C Isolation valve /I Blow back valves / BB Blow back valves /BB/F Flange SP2020-H.... 3“ 150 Ibs 115V AC tube connector 1/4“o.d. tube connector 3/8“o.d. /H220 /C /I /BB /BB/F SP2020-H/C/I/BB SP2020-H/C/I/BB/F SP2020-H220/C/I/BB SP2020-H220/C/I/BB/F 20S2020a 20S2025a 20S2021a 20S2030a max. 180 °C max. 220°C 115V 60Hz, 630W Check valve, cracking pressure: >0,7 bar g connection: tube connector 1/4“ o.d. Bellow valve with pneum, actuator, control pressure: 3-10 bar g connection: 1/8“NPT i High flow rate check valve, cracking pressure: >0,7 bar g, recommended: 3-6 bar g we recommend short pressure pushes to avoid decreasing of temperature in blow back area. connection: tube connector 3/8“ o.d. material: stainless steel 316Ti, dimensions: 3“ 150 Ibs For further technical informations see standard probe SP2000-H. 2/2 2-1.1.6.1 © M&C 09.96 / 06.01 Technical details are subject to change. Copying, including extracts, not permitted unless authorized by M&C. M&C Products Analysentechnik GmbH • Rehhecke 79 • 40885 Ratingen • Germany • Tel.: +49 (0) 21 02 / 9 35-0 • Fax: / 9 35-111 • E-mail: info@muc-products.de • www.muc-products.de