Light String Ray Milky Flex 35 Basic Specifications
Transcription
Light String Ray Milky Flex 35 Basic Specifications
Light String TR-13956 REV.2 Ray Milky Flex 35 Technical Data Sheet Basic Specifications Color(when unlit); Translucent white Cladding : Fluorocarbon polymer Specifications/ Outer diameter φ3.5±0.2mm Coefficient of thermal expansion; 1.0×10-4 Rate of attenuation( @570nm ); 1.6% / cm Allowable input wavelength; 400nm to 720nm Core : Methacrylic polymer Characteristic Data Table Luminance variation Color variation -Rate of luminance variation*Note1 -(X.Y.)Coordinate variation*Note2 No significant luminance variation is observed. No significant color variation is observed. -43% ~ +2% ( X, Y, ) = (± 0.02, ± 0.03 ) Heat cycle resistance o 100 C×24hr → R.T. o → -40 C×24hr → R.T. ( 4 cycles) Heat shock resistance o o 80 C×4hr → -30 C×4hr ( 4 cycles) No significant luminance variation is observed. No significant color variation is observed. -37% ~ -8% ( X, Y, ) = (± 0.01, ± 0.01 ) No significant luminance variation is observed. No significant color variation is observed. -21% ~ -13% ( X, Y, ) = (± 0.01, ± 0.01 ) Heat and wet cycle resistance No significant luminance variation is observed. No significant color variation is observed. Heat resistance o ( 100 Cx500hr ) -40oC×7.5hr → R.T. → o 80 C×15.5hr → R.T. → o -40 C×7.5hr → R.T. → o 50 C・95% ×15.5hr → R.T. ( 4 cycles) Humidity resistance o ( 50 C・95%RH ×500hr ) Water immersion o (40 Cwater×500hr) Cold resistance o ( -40 C x500hr ) Weather resistance Xenon weather meter 1000hr -22% ~ -11% ( X, Y, ) = (± 0.01, ± 0.01 ) No significant luminance variation is observed. No significant color variation is observed. -34% ~ +14% ( X, Y, ) = (± 0.01, ± 0.01 ) No significant luminance variation is observed. No significant color variation is observed. -12% ~ +2% ( X, Y, ) = (± 0.01 , ± 0.01 ) No significant luminance variation is observed. No significant color variation is observed. -7% ~ -1% ( X, Y, ) = (± 0.01, ± 0.01 ) No significant luminance variation is observed. No significant color variation is observed. -10% ~ +2% ( X, Y, ) = (± 0.01, ± 0.01 ) Length Variation Outer diameter variation -Rate of Total Length Variation*Note3 -Rate of outer diameter variation- -0.29% 0.01 -0.27% 0.02 -0.16% 0.01 -0.11% 0.02 -0.15% 0.01 -0.08% 0.01 0.04% -0.01 0.05% 0.01 Test description Condition Luminance and color evaluation method Cut sample with the length of 1000mm was inserted into each testing conditions. After dwelled the samples left at room temperature for at least 30minutes before measurements. *Note4 , inserted into transparent linear pipe, and then the side Either end of sample was connected to a 1W white LED luminance and the color was measured at the 10, 20, 30, 40, 50, 60, 70, 80, 90cm points from the LED connection end. Outer diameter evaluation The outer diameter was measured at 6 points in the circumferential direction at points near the exact center in the lengthwise direction of each sample. method Length evaluation method Each sample was inserted into 10mm-width linear grooves, and the length was measured. *Note1 The luminance variation is based on human perception, and so the effect of the rate of variation was measured based on the Fechner's law which states that the strength of a sensation is proportional to the logarithm of the stimulus. Normally the range of -50% to +100% is considered to have no effect. *Note2 Color variation was determined by the effect of color variation based on the CIE chromaticity diagram developed by the International Commission on Illumination (CIE) in 1931 (ref. next figure) *Note3 The protrusion of core part with 1-2 mm length may occure at both ends due to shrinkage of cladding after a series of durability test. *Note4 Light flux: 45 lumens, Directional pattern (2Θ1/2):110° 3M™ Light LightString String Ray Milky Flex 35 Graphs Ray Milky Flex 35 _ Graphs Color Variation - (X.Y.) Coordinate Variation (60cm point from the light source) Luminosity Variation - Rate of Luminance Variation (60cm point from the light source) After test Heat resistance Before test Y1 63.4 49.8 0.9 Heat cycle resistance 47.7 Heat shock resistance 62.8 0.8 64.2 54.6 Heat and wet cycle resistance 69.6 57.9 Humidity resistance 62.7 64.8 Water immersion 65.6 65.6 Cold resistance 67 65.4 Weathering Meter Xenon (40cm) 95.1 85.7 1 Luminance (Cd/m2) 10 0.7 Heat resistance 0.6 Heat cycle resistance 0.5 Heat shock resistance 0.4 Heat and wet cycle resistance 0.3 Humidity resistance 0.2 Water immersion 0.1 Cold resistance 0 100 0 0.2 0.3 0.4 0.5 0.6 0.7 Weather resistance 0.8 0.9 1 Xenon(40cm) Outer Diameter Variation - R ate of Outer Diameter Variation - Length variation - Rate of Total Length Variation - -2.5% 0.1 Heat resistance -0.29% Heat resistance Heat cycle resistance -0.27% Heat cycle resistance Heat shock resistance -0.16% Heat shock resistance Heat and wet cycle resistance -0.11% Heat and wet cycle resistance Humidity resistance -0.15% Humidity resistance 0.01 Water immersion -0.08% Water immersion 0.01 -2.0% Cold resistance 0.04% Cold resistance Weather resistance 0.05% Weather resistance -1.5% -1.0% -0.5% 0.0% 0.5% 1.0% 1.5% -0.15 -0.10 -0.05 X 0.01 0.02 0.01 0.02 -0.01 0.01 0.00 0.05 (mm) 0.10 Notes 1. Dark spots may occur in illumination from the cut surface to about 10mm due to air gap between the core and cladding. 2. Do not repeatedly bend, stretch, or subject the Light String to strong impact. This could damage it. 3. Be careful not to damage the Light String when installing it. If it hits a hard object or scrapes against the floor, the cladding can be damaged, and the illumination quality can be adversely affected. 4. Do not apply high tension to the Light String when connecting or securing it. If it is stretched, the illumination quality can be adversely affected. 5. Please contact 3M about displacement absorption methods in the longitudinal direction. ・The technical information and data, recommendations, and other statesments provided in this document are based on tests which 3M believes to be reliable, but the accuracy and completeness of such information is not guaranteed. ・The user is responsible for determining beforehand whether a product is suitable for a particular purpose and assumes all responsiblity for any hazards inherent with the use of the product. ・If any product is proved to be defective, the seller and manufacturer are responsible only for replacement of the defective product. 3M is not liable for information and recommendations not included in this document unless provided for in a written agreement signed by authorized officers of the seller or manufacturer. 3M is a trademark of 3M Company. Sumitomo Limited 3M Automotive3M Division Automotive http://www.mmm.co.jp/auto/ 3M Center, Building Division 223-1S-02 St. Paul, MN 55144-1000 2-33-1Tamagawa-dai Setagaya, Tokyo 158-8583 www.3M.com/lighting Tel : 03(3709)-9433 3