iGuzzini new Headquarters, Recanati
Transcription
iGuzzini new Headquarters, Recanati
iGuzzini new Headquarters, Recanati SOUTH-WEST VIEW NORTH-EST VIEW SIMULATIONS OF SOLAR EXPOSITION BUILDING STATISTICS Type of building: office building End of construction: 2009 Location: Recanati, Italy Size: 6.000 m2 Occupancy: 956 + 280 Energy Demand for winter air conditioning : 5,57 KWh/m3 Energy Demand for summer air conditioning: <22 KWh/m3 Heated volume : 28.805 m3 Cooled volume: 18.550 m3 EXTERNAL VIEW iGuzzini new Headquarters, Recanati ground floor plan sections roof plan iGuzzini new Headquarters, Recanati DAZZLING STUDY IN THE ABSENCE OF SHIELD shields with courtains into double skin From the analysis, notes that in the middle hours of summer's day with all the tents lowered, results that the level of illumination is inadequate and must use artificial light even when sunscreen is not necessary (as there isn't a significant solar penetration) and when there is a large availability of natural light widespread. With the use of daylight simulation software, luminance was estimated in the workplace in order to assess the visual comfort due to the contribution of only natural light. The conditions of comfort is satisfied when the luminance is less than 1000 cd/m2. shields with internal courtains For a better reading of the images that follow are two points of view: 1. Blue Point: View from the floor with section plan to place third; 2. Yellow Point : View of an operator from their jobs place on the east side of the offices area. OPTIMIZE ENVELOPE Result in terms of primary energy requirements of the comparison made between the various project proposals for two types of tends to roll with thermal performance and different energy The results obtained shows that the adjustment external tents - internal tents can be optimized to maximize the benefits of energy, thermal and visual comfort and level of illumination in the different natural conditions of insolation for the different façades of the several hours in the day. In the middle hours of the day in summer, you can take lowered the sun tents on the external facade on the south and use the internal sun tents all other sides, maximizing the level of natural illumination without compromising energy consumption for air conditioning. WINTER ENERGETIC PERFORMANCE (heating period) SUMMER ENERGETIC PERFORMANCE (cooling period) Result in terms of primary energy requirements of the final solution project for the winter heating Summer air conditioning CO2 EMIMSSIONS BUILDING CONSUMPTION DEVIDED FOR TYPE CO2 emissions distributed monthly (a) and annual (b). The building, locally, is zero emissions of CO2 Requirements of Energy of different configurations analysed, considering only the contributions of Heating and Cooling. DOUBLE SKIN FAÇADE SYSTEM iGuzzini new Headquarters, Recanati PREVISION ON KEY PERFORMANCE INDICATORS (KPI) Type of building: Office building Date of construction: 2009 Location: Recanati Italy Phase of verification: executive plan performance points Issues Weights Scores -1 0 1 2 3 4 5 Building weighted score 3,5