Ray set Measurement Z5 PKG SSC R&D Center 2014.11.06

Transcription

Ray set Measurement Z5 PKG SSC R&D Center 2014.11.06
Ray set Measurement
Z5 PKG
SSC R&D Center
2014.11.06
Sung Ki Hwang
Copyright ⓒ Seoul Semiconductor Co., Ltd.
www.seoulsemicon.com
Legal Disclaimer
Information in this presentation is provided in connection with Seoul Semiconductor
products and/or business operation. While Seoul Semiconductor has made every attempt
to ensure that the information contained in this presentation has been obtained from
reliable sources, Seoul Semiconductor is not responsible for any errors or omissions, or
for the results obtained from the use of this information.
All information in this presentation is provided “as if” with no guarantee of completeness,
accuracy, timeliness or of the results obtained from the use of this information, and
without warranty of any kind, express or implied, including, but not limited to warranties of
merchantability, performance, and fitness for a particular purpose, or any warranty
otherwise arising out of any proposal, specification, or sample.
In no event will Seoul Semiconductor, its related corporations, or the employees thereof
be liable to you or anyone else for any decision made or action taken in reliance of the
information in this presentation or for any consequential, special or similar damages, even
if advised of the possibility of such damages.
Copyright ⓒ Seoul Semiconductor Co., Ltd.
www.seoulsemicon.com
1. Measurement Conditions
(1) Common Information
Package Name
Z5 PKG
Operating Current / Voltage
350mA / 3.1V
Measuring Date
2014.11.06
Burn in Time
> 1 Hour
(2) Position and Orientation
The following views are showing the origin position of the ray data coordinate system referring to the measuring object.
The images are captured by the luminance measuring camera at the given angles of the goniometer coordinate system
(spherical coordinates)
z
y
x
x
View in Z axis(Theta = 0°, Phi = 90°)
View in Z axis(Theta = -90°, Phi = 90°)
Goniometer coordinate system
* Measuring equipment and software : RIGO801, Converter801 (TechnoTeam, Germany)
Copyright ⓒ Seoul Semiconductor Co., Ltd.
Company Confidential
www.seoulsemicon.com
2. Measurement results
(1) Measuring Parameter
(3) Conversion Format
Theta Range
-90° ~ 90°
Pos.
Conversion Format
Number of Rays
File Name
Theta Step
2.5°
1
LightTools
1e6
Z5_1M_LightTools.txt
Phi Range
0° ~ 180°
2
Phi Step
2.5°
LightTools besides 6 kind program
*.Six kind program : ASAP, LucidShape, Zemax, TracePro, Speos, SimuLux
(2) Intensity Distribution
Polar plot
3D view
Spectrum
Viewing angle : 112deg
Copyright ⓒ Seoul Semiconductor Co., Ltd.
Company Confidential
www.seoulsemicon.com
THANK YOU!
www.seoulsemicon.com

Similar documents

Global Semiconductor Assembly Test Services Market - Trends, Size, Share, Analysis to 2021

Global Semiconductor Assembly Test Services Market - Trends, Size, Share, Analysis to 2021 The global semiconductor assembly & testing services market is anticipated to expand at a CAGR of 4.7% during the period 2015-2021 to reach US$ 39,050.7 Mn by 2021. The global semiconductor assembly & testing services market was valued at US$ 28,177.9 Mn in 2014. Increasing adoption of consumer electronics products including tablet PCs, wearable devices (smart watches, smart glasses, head mounted displays, fitness equipment etc.), gaming consoles, audio/video devices along with the rising penetration of smartphones in the communications segment is driving the overall SATS market growth.