Ray set Measurement Z5 PKG SSC R&D Center 2014.11.06
Transcription
Ray set Measurement Z5 PKG SSC R&D Center 2014.11.06
Ray set Measurement Z5 PKG SSC R&D Center 2014.11.06 Sung Ki Hwang Copyright ⓒ Seoul Semiconductor Co., Ltd. www.seoulsemicon.com Legal Disclaimer Information in this presentation is provided in connection with Seoul Semiconductor products and/or business operation. While Seoul Semiconductor has made every attempt to ensure that the information contained in this presentation has been obtained from reliable sources, Seoul Semiconductor is not responsible for any errors or omissions, or for the results obtained from the use of this information. All information in this presentation is provided “as if” with no guarantee of completeness, accuracy, timeliness or of the results obtained from the use of this information, and without warranty of any kind, express or implied, including, but not limited to warranties of merchantability, performance, and fitness for a particular purpose, or any warranty otherwise arising out of any proposal, specification, or sample. In no event will Seoul Semiconductor, its related corporations, or the employees thereof be liable to you or anyone else for any decision made or action taken in reliance of the information in this presentation or for any consequential, special or similar damages, even if advised of the possibility of such damages. Copyright ⓒ Seoul Semiconductor Co., Ltd. www.seoulsemicon.com 1. Measurement Conditions (1) Common Information Package Name Z5 PKG Operating Current / Voltage 350mA / 3.1V Measuring Date 2014.11.06 Burn in Time > 1 Hour (2) Position and Orientation The following views are showing the origin position of the ray data coordinate system referring to the measuring object. The images are captured by the luminance measuring camera at the given angles of the goniometer coordinate system (spherical coordinates) z y x x View in Z axis(Theta = 0°, Phi = 90°) View in Z axis(Theta = -90°, Phi = 90°) Goniometer coordinate system * Measuring equipment and software : RIGO801, Converter801 (TechnoTeam, Germany) Copyright ⓒ Seoul Semiconductor Co., Ltd. Company Confidential www.seoulsemicon.com 2. Measurement results (1) Measuring Parameter (3) Conversion Format Theta Range -90° ~ 90° Pos. Conversion Format Number of Rays File Name Theta Step 2.5° 1 LightTools 1e6 Z5_1M_LightTools.txt Phi Range 0° ~ 180° 2 Phi Step 2.5° LightTools besides 6 kind program *.Six kind program : ASAP, LucidShape, Zemax, TracePro, Speos, SimuLux (2) Intensity Distribution Polar plot 3D view Spectrum Viewing angle : 112deg Copyright ⓒ Seoul Semiconductor Co., Ltd. Company Confidential www.seoulsemicon.com THANK YOU! www.seoulsemicon.com
Similar documents
Global Semiconductor Assembly Test Services Market - Trends, Size, Share, Analysis to 2021
The global semiconductor assembly & testing services market is anticipated to expand at a CAGR of 4.7% during the period 2015-2021 to reach US$ 39,050.7 Mn by 2021. The global semiconductor assembly & testing services market was valued at US$ 28,177.9 Mn in 2014. Increasing adoption of consumer electronics products including tablet PCs, wearable devices (smart watches, smart glasses, head mounted displays, fitness equipment etc.), gaming consoles, audio/video devices along with the rising penetration of smartphones in the communications segment is driving the overall SATS market growth.
More information