Firmware Release Notes
Transcription
Firmware Release Notes
Current Firmware Revision: 1.01.0000-b015 The following notes provide the revision history and a list of known firmware issues in the current release. For more information, please call your Extron Application Engineer. Updated: April 7, 2015 Extron Products Affected: TLP Pro 520M TECH NOTES Updating firmware – TouchLink Pro firmware can be updated from Extron’s Toolbelt Utility within Global Configurator Plus and Professional. Alternatively, the firmware can be updated via the embedded web pages on TouchLink Pro touchpanels. Please consults the User’s Manual for more information on uploading via the embedded pages. If downgrading firmware from v1.01.0000-b015 or higher to v1.00.0010-b006 or lower, you must reset and reboot the unit. Renaming the firmware file - Please avoid renaming the firmware file with spaces or special characters except for hyphen and underscore as that will result in a firmware update failure. Room Agent Support – Please see Room Agent release notes for minimum firmware versions required for the current release of the software. If the TouchLink Pro touchpanel was previously configured with Global Configurator Plus or Professional, a reset of the touchpanel from Toolbelt or a factory reset is required prior to using Room Agent. Page 1 49-192-50 Rev. 1.01.0000-b015 KNOWN ISSUES The following is a list of known firmware issues found in the TLP Pro 520M firmware version 1.01.0000-b015 Issue (originated in v1.00.0008) – Text inconsistencies between GUI Designer and the touchpanel – Text configured in GUI Designer may appear differently when the project is running on the touchpanel. Differences may include font styles, font size, text alignment, text padding and/or word wrapping. Use regular style fonts and extend the width/height of GUI Designer text objects to minimize the effects of the text differences. Page 2 49-192-50 Rev. 1.01.0000-b015 FIRMWARE RELEASE HISTORY Released Version: 1.01.0000-b015 Affects: Firmware Revision: 1.00.0010-b006 Date: Units shipped prior to April 13, 2015 The following is a list of changes and fixes in this release. Added Feature – Support for Room Agent software - Firmware version 1.01.0000-b015 or later is required to support Room Agent software. Fixed Issue (originated in v1.00.0010-b007) – Popup pages not hiding when the touchpanel is in sleep mode – Hide All Popups and Hide Popup commands are not triggering while the touchpanel is in the sleep state resulting in the touchpanel being out of sync with the system. This issue has been resolved in version 1.01.0000-b015. Fixed Issue (originated in v1.00.0010-b007) – Click sounds not working after a build and upload from Global Configurator – Occasionally click sounds will stop working after a Global Configurator project is built and uploaded to a system. This issue has been resolved in version 1.01.0000-b015. Page 3 49-192-50 Rev. 1.01.0000-b015 FIRMWARE RELEASE HISTORY Released Version: 1.00.0010-b006 Affects: Firmware Revision: 1.00.0009-b005 Date: Units shipped prior to December 18, 2014 The following is a list of changes and fixes in this release. Fixed Issue (originated in v1.00.0009-b005) – Unit becomes unresponsive when entering setup menu – Entering setup menu multiple times back to back may cause the unit to become unresponsive. This issue has been resolved in version 1.00.0010-b006. Fixed Issue (originated in v1.00.0009-b005) – Buttons are not visible if state 0 is removed – Buttons with a single state will not appear on the TLP if the state is any state but state 0. This issue has been resolved in version 1.00.0010b006. Fixed Issue (originated in v1.00.0009-b005) – Button press triggered when waking panel – If waking the panel with a touch of screen and the finger lands on an area that has a button, that button may trigger its actions. This issue has been resolved in version 1.00.0010-b006. Fixed Issue (originated in v1.00.0009-b005) – 12 hour time format appears as 24 hour time format – 12 hour time format h:mm incorrectly appears as 24 hour time format H:mm. This issue has been resolved in version 1.00.0010-b006. Enhanced project initialization performance (originated in v1.00.0009b005) – Project initialization time after a build and upload from Global Configurator Plus or Pro has been significantly improved. Page 4 49-192-50 Rev. 1.01.0000-b015 FIRMWARE RELEASE HISTORY Released Version: 1.00.0009-b005 Affects: Firmware Revision: 1.00.0008 Date: Units shipped prior to September 2, 2014 The following is a list of changes and fixes in this release. Fixed Issue (originated in v1.00.0008) – Text characters are cut off at the top – The text characters may appear to be cut off at the top when using certain fonts at certain sizes. This issue has been resolved in version 1.00.0009-b005. Fixed Issue (originated in v1.00.0008) – Popup pages not appearing when called – Popup pages will not appear if they are called while the page with that popup’s reference is hidden. This issue has been resolved in version 1.00.0009-b005. Fixed Issue (originated in v1.00.0008) – Time values between multiple TouchLink Pro touchpanels are not in sync – Time objects that do not have seconds in the time format may appear out of sync between different TouchLink Pro touchpanels connected to the same control processor. This issue has been resolved in version 1.00.0009-b005. Page 5 49-192-50 Rev. 1.01.0000-b015 FIRMWARE RELEASE HISTORY Released Version: 1.00.0008 Affects: Firmware Revision: N/A Date: April 30, 2014 The following is a list of changes and fixes in this release. Initial Release – This is the initial release of this software product. Page 6 49-192-50 Rev. 1.01.0000-b015