OHS Catalogue v 27 - Kenelec Scientific

Transcription

OHS Catalogue v 27 - Kenelec Scientific
OH&S
CATALOGUE
TECHNICAL CATALOGUE 27
kenelec.com.au
1300 73 22 33
WELCOME TO
KENELEC SCIENTIFIC
Established in 1962, Kenelec Scientific is one
of Australia’s leading scientific & environmental
technology companies.
With offices in Sydney and Melbourne and key
distributors located throughout Australia and
New Zealand, we are recognised as well connected,
innovative industry leaders in the supply of globally
sourced, latest generation technologies, at
competitive prices.
We provide an extensive range of scientific and
environmental solutions, employing highly trained and
experienced sales and technical staff. We also maintain
state-of-the-art NATA accredited calibration laboratories
offering a range of popular laboratory services. In house
professional services to assist in design, installation and
ongoing maintenance are also available.
We operate a Quality Management System that fully
complies to ISO 9001:2008 and is committed to
providing the highest level of service and technical
support on a wide range of quality products.
We strive to understand your needs and offer solutions,
off the shelf or adapted in house, to suit the project.
The strong relationships forged with our customers,
suppliers and other stakeholders over the many years
are testament to the dedication of our staff, many of
whom have over 20 years experience with us. Kenelec
Scientific is 100% Australian owned, with a reputation
for integrity and reliability forged over 50 years.
Please enjoy this new edition. For further information or
product advice our contact details are below.
We look forward to working with you.
Validation services to industry are offered and repairs
and service is carried out at our Melbourne facility by
factory trained technicians. Many products are stocked
for sale or are available for short and long term rental.
sales@kenelec.com.au
www.kenelec.com.au
Kenelec Scientific Pty Ltd
Australia & NZ Head Office
Kenelec Scientific Pty Ltd
NSW Office
23 Redland Drive
Mitcham VIC 3132
Australia
Building 5, 49 Frenchs Forest Rd
Frenchs Forest NSW 2086
Australia
T +61 3 9873 1022
F +61 3 9873 0200
T +61 2 8977 4017
F +61 2 8977 4000
OCCUPATIONAL
HEALTH & SAFETY
RESPIRATOR FIT TESTING
4
Mask Fit Testing - Why Fit Test?...................................................... 4
IAQ & GAS MONITORING
18
Indoor Air Quality........................................................................... 18
Portable Gas Monitors................................................................... 19
AIR SAMPLING
6
Introduction to Aerosol Particle Sizes and Health Hazards............. 6
Real Time - Aerosol Monitoring....................................................... 7
Gas Detection Controllers.............................................................. 20
HOSPITALS & LABS
22
Real-time DPM Monitoring............................................................... 7
PresSura Room Pressure Products............................................... 22
Gravimetric Analysis - Air Sampling Pumps.................................... 8
Fume Hood Monitors..................................................................... 23
Accessories for Sample Pumps....................................................... 9
Fume Hood Controllers.................................................................. 24
Preassembled Air Sampling Filter Cassettes................................. 10
Ventilator Test Systems.................................................................. 25
Unassembled Air Sampling Filter Cassettes.................................. 11
Mass Flow Meters.......................................................................... 26
DustTrak - Aerosol Mass Concentration Measurement................. 12
Primary Calibrators........................................................................ 27
Particle Counting............................................................................ 13
Nanoparticle Surface Area Monitor................................................ 13
SOUND & VIBRATION
28
ASBESTOS14
Difference between Lmax, Lmin and Peak.................................... 28
Abatement Sampling Pumps......................................................... 14
Noise at Work Measurement.......................................................... 29
Asbestos Sampling Cassettes & Accessories............................... 15
Environmental Sound Measurement.............................................. 30
Sound Level Meters....................................................................... 28
Combined Safety / Environmental Sound Measurement............... 30
MICROBIAL SAMPLING
16
Noise Recording - NoiseLog.......................................................... 32
Bio Pump Sampling....................................................................... 16
Vibration Instruments - Condition Monitoring................................ 34
Other Sampling Technologies........................................................ 17
Vibration Instruments – Human Vibration Measurement............... 35
Noise Activated Warning Systems................................................. 32
Please note: the prices in this catalogue are provided as a guide only at April 2015 and are
subject to change without notice. Delivery cost and GST are not included.
Errors and omissions excluded.
RESPIRATOR FIT TESTING
MASK FIT TESTING - WHY FIT TEST?
Under Australian and NZ Standards, everyone using a mask in any workplace
must be fit tested before starting, and at least annually thereafter. Without an
enforced, documented fit testing program, your organisation could be found
legally liable as an unsafe workplace.
Verification of Training
A Fit Test checks that the worker has learned how to properly put on and wear a
respirator without assistance.
Sizing
Fully
complies
with:
AS/NZS 1715:
2009
OHSA (USA)
HSE (UK)
It is important to make sure that a respirator is the right size and therefore
capable of providing protection when worn properly.
Quantitative fit testing is accurate, fast and safe for your workers.
PORTACOUNT results are immediate and unambiguous.
Take a step up from the old-fashioned guesswork of qualitative fit testing and
provide an objective measurement of the quality of the seal between the wearer’s
face and the facepiece; producing a Fit Factor for each staff member in real time
Fit Factor
A Fit Factor is a measure of how well a particular face piece seals against a
person’s face. It is a number that is the direct result of a measurement made
during a simulation of workplace activities (the exercises). It is a ratio of the
number of particles inside and outside of the mask. The PortaCount can measure
fit factors from 1 to over 10 000. Due to the precision of its patented particle
counter, the PortaCount is considered by far the world’s most accurate Fit Tester.
FF=
Particle Count Outside Respirator
Particle Count Inside Facepiece
How it works
The PortaCount® respirator fit testing equipment measures real-time fit while the
user performs a series of moving, breathing and talking exercises designed to
simulate the same movements made in the workplace. The step by step process
is guided via the FitPro+™ Fit Test Software and stored in a database for easy
report generation, retrieval and regulatory compliance. The stored data is easily
transferrable via a USB drive.
PortaCount can be operated by itself or it can also be connected to your own
external computer to generate reports and print fit test cards.
No other fit tester can quantitatively fit test so many types of respirators—gas
masks, SCBAs, respirators, even disposables (with the 8038 model).
Adaptor Kits
Mask adapters kits allow a worker to be fit tested in their own mask. Available
for an extensive range of respirators throughout Australia, you can order many
models from Kenelec or your respirator manufacturer.
To PortaCount Pro
Class-100 Filter
Cartridge
Adapter’s
Inhalation Valve
Sampling Adapter
Sample Inlet
Sample Tube
Cap
Suction Cup
Use the Real-time Fit Factor Display to show
workers the real-time effects of mask positioning
and strap tightness as they experiment and learn
proper donning procedures.
Software
FitPro software provides the vital documentation you need for your respirator
program. You can provide management with hard-copy evidence that each
employee passed a fit test, was trained to don the respirator properly and
assigned a mask size that fits correctly.
Each PortaCount comes with the software and also access to free online training
modules, webinars and free lifetime updates.
If you have multiple PortaCounts the FitPro software enables you to fit test up to
4 people simultaneously - saving time and money.
4
Fit factors for anyone who has smoked recently
will be lower than that individual deserves and may
even cause them to fail the fit test entirely. Smokers
exhale particles for at least 30 minutes after they
have been smoking. The PortaCount Pro fit tester
can count these particles and will interpret them
as if they were caused by face seal leakage. Avoid
retests by instructing smokers not to smoke for at
least 30 minutes prior to fit testing.
KENELEC.COM.AU / 1300 73 22 33
RESPIRATOR FIT TESTING
TSI 8030 PORTACOUNT PRO RESPIRATOR FIT TESTER
TSI 8038 PORTACOUNT PRO+ RESPIRATOR FIT TESTER
RENT
ME
The starter model in the series will fit test all respirators except P1, P2 and N95
disposables.
The 8038 model will fit test all respirators including P1, P2 and N95 disposable
masks. Everybody, including site visitors, can be tested at a moments notice.
General Features
General Features
• OSHA-compliant for all gas masks, SCBAs, respirators, respirators (full & half
faced) but NOT P1, P2 N95 disposables.
• Measures fit factors from 1 to greater than 10,000
• Automates fit testing with FitPro Fit Test software
• Optional mask sampling adapters allow employees to be tested in their own
respirators
• Software prints fit test cards with fit test report or on ID cards
• OSHA-compliant for all gas masks, SCBAs, respirators (full & half faced)
INCLUDING P1, P2 N95 disposables.
• Measures fit factors from 1 to greater than 10,000
• Includes 8026 Particle Generator to make Fit Testing easier in cleanrooms or
airconditioned offices
• Automates fit testing with FitPro Fit Test software
• Optional mask sampling adapters allow employees to be tested in their own
respirators
• Software prints fit test cards with fit test report or on ID cards
Options
■■FIT TEST CARD PRINTER
■■ADAPTOR KITS
CALL FOR MORE INFO
MASK INTEGRITY TEST ACCESSORY
You’ve just cleaned your mask? Do you bet your life that you’ve
reassembled it correctly?
Designed by the leaders in quantitative fit testing technology, the TSI Mask
Integrity Test Accessory (MITA) 8120 works in tandem with a PortaCount
Respirator Fit Tester or CBRN Mask Protection Assessment Test System to
quickly detect leaks in CBRN gas masks and commercial respirators and ensure
your personnel are getting maximum protection.
While under conditions of negative pressure and constant flow, the mask is
tested on a full head form with an enhanced bladder seal system to provide a
tight seal for most gas mask and full face respirator types and sizes. Testing
the mask on this full head form configuration allows for use of the mask’s head
harness, mimicking a real-life application and providing better representative
results. Unlike anything else on the market*, when a leak is detected during
the assessment, the integrated aerosol wand and generator is used to pinpoint
invisible leaks for quick evaluation and repair. Additionally, MITA is capable of
testing the integrity of a mask’s exhalation valve and drink tube when applicable.
KENELEC.COM.AU / 1300 73 22 33
Some competitor models are not mask integrity testers. Their main function is
to test SCBA regulators, air bottles and for some, test the step-down/breathing
flow. Some units also use +/- pressure to check for large leaks, but since they do
not generate particles, they do not have the sensitivity to determine where the
mask is leaking from.
General Features
• Separate tests for overall mask integrity (Protection Factor), exhalation valve
and drink tube
• Integrated aerosol wand pinpoints leak locations, allowing for immediate
evaluation and repair, potentially avoiding replacement costs
• Efficient test sequence allows allows testing of up to 20 masks per hour
*at March 2015
5
AIR SAMPLING
INTRODUCTION TO AEROSOL PARTICLE SIZES AND HEALTH HAZARDS
Particle Size-Selective Dust Sampling
Particle Size
Inhalable
Thoracic
(Total dust)
Respirable
Welding Fume
Combustion Nuclei
Wind blown dust
Types of Particles
Diesel Engine Exhaust
Fly Ash
Particle-size selective TLVs consider two points:
Volcanic emissions
Paint Pigment
Oil Smoke
1 The size-fraction most closely associated with the
specific health effect
Pollen
Sea salt
Construction Activities
Soot
Bacteria
Virus
0.01
The ACGIH recommends that particle-size selective
TLVs be expressed in three forms:
Coal Dust (mining)
Tobacco smoke
0.001
2 The mass concentration within that size fraction
which should represent the TLV
Vacuuming
Carbon Black
0.1
1
[micron (μm)]
Particle Size Range (micrometers
)
The hazard potential of airborne dust, solid
particles, or droplets is dependent on the mass
concentration as well as the particle size. Particle
size determines the deposition site within the
respiratory tract and the subsequent health
effect. Therefore, the American Conference of
Governmental Industrial Hygienists (ACGIH®) has
recommended that particle-size selective Threshold
Limit Values (TLV®s) be developed for inhalation
hazards in the workplace.
4 10
100
Environmental / Naturally Occurring Particles
Workplace / man-made Particles
• Inhalable Particulate Mass
Airborne particles having a 50% cut-point of
100µm. These dust particles are hazardous no
matter where they are deposited in the respiratory
tract
• Thoracic Particulate Mass
Airborne particles having a 50% cut-point of
10µm. These dust particles are hazardous when
deposited anywhere in the lung airways and gasexchange regions
• Respirable Particulate Mass
Airborne particles having a 50% cut-point of
4µm. These dust particles are hazardous when
deposited in the nonciliated gas-exchange
regions of the lung
RESPIRATORY DEPOSITION
Blood Vessel
Posterior Nasal
Passage
Extrathoracic
Region
Pharynx
% Regional Deposition
1.0
0.8
0.6
Nasal, Pharyngeal,
Laryngeal
0.4
0.2
0
0.001
Larynx
0.01
0.1
1
10
Diameter (μm)
Tranchea
Trancheobronchial
Region
Alveoli
Bronchiole
Alveoli
% Regional Deposition
1.0
Bronchus
Alveolar
Region
0.8
Trancheobronchial
0.6
0.4
0.2
0
0.001
0.01
0.1
1
10
Diameter (μm)
Unlike larger particles, ultra-fine particles are more easily inhaled and can
penetrate deep into the lungs, potentially causing serious health effects.
Below .05μm (micron) these particles can be absorbed directly into the
blood stream, which again can cause a wide range of serious health
problems.
6
% Regional Deposition
1.0
Reference: ICRP 1994
0.8
Alveolar
0.6
0.4
0.2
0
0.001
0.01
0.1
1
10
Diameter (μm)
KENELEC.COM.AU / 1300 73 22 33
AIR SAMPLING
REAL TIME - AEROSOL MONITORING
TSI AM510 SIDEPAK PERSONAL AEROSOL MONITOR
RENT
ME
With sampling pumps, you simply don’t get that
dynamic real-time data that you can get with a TSI
real-time AM510 monitor. The SIDEPAK AM510
series of personal aerosol monitors are rugged,
lightweight, belt-mounted laser photometers. The
built-in sampling pump lets you attach a wide
variety of size-selective inlet conditioners for
worker breathing zone or area measurements with
a respirable cyclone or one of the three integrated
impactors. The easy-to-read display shows your
data in both real-time aerosol mass concentration
and 8-hour time-weighted average (TWA), with
datalogging enabling you to download stats to
produce graphs and reports.
General Features
• 0.1μm to 10μm particle size range
• 1 ug/m3 to 20 mg/m3 concentration range
• 33,000 point data logging with software
• Ideal for indoor air, environmental & OH&S work
• Built-in pump, battery operated, ready to use
Options
■■AA BATTERY MODEL
■■1650mAh BATTERY MODEL
■■2700mAh BATTERY MODEL
REAL-TIME DPM MONITORING
RENT
ME
Elemental Carbon (μg/m3)
FLIR AIRTEC REAL-TIME DPM ELEMENTAL CARBON MONITOR
800
600
400
200
0
09:00
12:00
15:00
Time (hrs)
8-hour TWA EC Concentration Comparison via:
1: NIOSH 5040 150.25 μg/m3
2: Airtec monitor 154.36 μg/m3
The Airtec monitor is a compact and highly portable
real-time elemental carbon monitor designed to
determine exposure of workers in underground
mines to DPM. Airtec uses a real time particle
capture and light transmission method to yield
elemental carbon values which closely correlate
with NIOSH 5040 test results to measure EC and
TC levels in underground mines.
This monitor is designed to allow the operator and
management to take immediate, remedial action to
address a problem area. Levels can also be tracked
over time to determine the possibility of long
term health hazards and help eliminate the risks
associated with over-exposure.
During monitoring the Airtec uses consumables,
generally a cassette will last a 12 hour shift with
a change of pre-filter cartridge for every three
cassettes used. The Airtec Starter Pack includes
one consumable kit to start you off and you can
order more depending on your requirements.
KENELEC.COM.AU / 1300 73 22 33
General Features
Options
• Displays elemental carbon levels in true real-time
• Laboratory accuracy in a small portable clip
on device
• Developed at the NIOSH research laboratories in
Pittsburgh, USA
• Precisely replicates results according to the NIOSH
5040 method in real-time
• Real-time instant results, no sending filter samples
off to labs
• Specifically detects DPM via EC measurements
• No cross sensitivity to other dusts and aerosols
• No more waiting days for results, saves time
and money
• Battery or AC powered for personal or
fixed monitoring
• 66.6 day data logging with software provided and
FREE updates
• Both audible and visual alarms
• Easy to change sample / analysis filter
■■WITH 4-20mA OUTPUT
Consumables
■■AIRTEC CONSUMABLE KIT
Contains 3x Cassettes and 1x Prefilter cartridge
7
AIR SAMPLING
GRAVIMETRIC ANALYSIS - AIR SAMPLING PUMPS
ESCORT LC AIR SAMPLING PUMP
The Escort LC Air Sampling Pump can be used with
a variety of personal and area sampling devices to
collect such airborne contaminants as asbestos
fibers, toxic gases, vapors, particulates, fumes and
mists. It can also be used to sample silica dust,
coal dust and organic vapors.
General Features
• Watertight case for occasional water spray
• Inlet filter traps particulate matter
• Separate LEDs indicate pump operation and low
battery
• Stainless steel-filled plastic case provides EMI/RFI
protection
• Exceptionally quiet operation
• Includes sampling line and charger
• 2 year warranty
Accessories
■■LEATHER CASE
ESCORT ELF AIR SAMPLING PUMP
RENT
ME
Escort ELF air sampling pumps feature a state of
the art electronic laminar flow sensor to provide a
constant flow control with ± 2.5% regulation of flow
rate (from 1-3 lpm) with automatic compensation
for changes in battery voltage, temperature,
altitude, and sample load. An internal secondary
standard calibrates the pump continuously and
needs to be checked against a primary standard
only once per month (or every 200 hours for coal
mine dust sampling).
General Features
• Patented electronic laminar flow control
• Internal secondary standard calibrates the pump
continuously, maintaining OSHA compliance
• Check against a primary standard only once a
month or every 200 hours for coal mine dust
sampling
• Inlet filter traps moisture and particular matter
• Rated IP66 for resistance to water and dust ingress
• Exceptionally quiet operation
• Flow-fault Indicator shows any sample inlet
blockage
• Run/hold feature allows “time out” during sampling
process
• Elapsed time readout and low-battery warning
• Low flow and dual tube sampling available with
Gemini Twin-Port Sampler
• 2 year warranty
Options
■■STANDARD
■■WITH SAMPLING LINE AND CHARGER ■■WITH GEMINI SAMPLER
Accessories
■■LEATHER CASE 8
KENELEC.COM.AU / 1300 73 22 33
AIR SAMPLING
TSI 4146 PRIMARY CALIBRATOR KIT
ZEFON DIGICAL 30 CALIBRATOR
KENELEC TECH TIP
RENT
ME
HOW DO I
PROPERLY
CALIBRATE
MY PUMP?
When sampling using filter
cassettes, the accuracy of your
sample collection depends
on an accurate amount of air
passing through the filter. Filter
cassettes create a high amount
of backpressure in the sampling
‘train’. So to calibrate the pump
airflow properly the sampling
‘train’ must be in a certain order.
Airflow must pass though the
calibrator first, then through
the media, and finally through
the pump. By configuring your
calibration setup this way, you are
measuring the flow rate of air as it
enters the filter.
The TSI Primary Calibrators are portable, batteryoperated units that are lightweight, easy to use and
accurate within 2% of reading. Volumetric flow rate
is displayed continuously so adjustments to pump
flow can be made in real-time. The LCD display is
easy to read.
General Features
• Range:0.01-20LPM
• Accuracy:
within 2%
• Battery powered, compact and lightweight
• NIST traceable calibration certificate
Options
A primary calibration device, the DigiCal™
Calibrator provides instantaneous calibration for
instruments like the Zefon Escort LC Pump or the
secondary flow standard inside the Escort ELF
Sampling Pumps. Just press the plunger and the
DigiCal Calibrator does the work. Its unique flow
cell replaces conventional bubble tubes and makes
calibration easier. The Digi-Cal Calibrator achieves
extreme accuracy by utilizing a computerized flow
meter that provides instantaneous flow readouts on
a digital display.
General Features
• Flow rate:
0.1 to 30LPM
■■TSI4046
Flow rate of 2.5 to 300LPM
ACCESSORIES FOR SAMPLE PUMPS
ZEFON HEAVY DUTY 10MM DORR-OLIVER
CYCLONE – FOR MINING - PART# 10044015
Designed to fit all standard 37mm Industrial Hygiene
(IH) cassettes the cyclone and holder are designed to
orient the cyclone in the proper position for sampling
and are fixed with a strong, spiked collar clip so they
won’t come off under even strenuous work.
ZEFON ALUMINUM CYCLONE FOR
RESPIRABLE DUST WITH HOLDER
PART# ZA0062
ZEFON 10MM STATIC CONDUCTIVE NYLON
CYCLONE WITH HOLDER - PART# ZA0081
This static conductive replica of the 10mm “DorrOliver” Nylon Cyclone eliminates any possible bias
in sampling results from static charging.
ZEFON UNIVERSAL CASSETTE AND CYCLONE
HOLDER - PART# ZA0061
ZEFON INHALABLE DUST SAMPLER WITH
CONDUCTIVE PLASTIC CASSETTE
A reusable filter cassette with a sampling head
designed to measure the worker’s exposure to
inhalable particulates and respirable dust. When
sampling at the recommended flow rate of 2 LPM,
it collects a particle size distribution that includes
particles of 100 micron and smaller. This meets
the definition set forth by ACGIH AND BRITISH
METHOD MDHS 14/3 for inhalable particulate.
Options
■■PLASTIC CASSETTE
PART# ZA0300
■■STAINLESS STEEL CASSETTE
PART# ZA0303
Cyclones are designed to
separate respirable dust
particles from non-respirable
particles and allow the
respirable particles to be
collected on a filter cassette.
This Zefon cyclone is a replica of the SKC
Aluminum Cyclone and is ideal for silica and
crystalline.
KENELEC.COM.AU / 1300 73 22 33
The Zefon Universal Cassette and Cyclone Holder
allows cassettes and cyclones to be attached onto
a workers collar. Compatible with 37mm cassettes,
25mm cassettes, and aluminum cyclones
manufactured by both Zefon and SKC.
9
AIR SAMPLING
PREASSEMBLED AIR SAMPLING FILTER CASSETTES
Zefon offers a complete line of 37mm air sampling cassettes manufactured
to meet all applicable NIOSH, OSHA, and EPA standards. All 37mm cassette
housings are manufactured in-house from polystyrene or polypropylene and are
available in two or three piece configurations. All 37mm cassettes are individually
assembled and preloaded under stringent quality assurance standards with only
the finest quality membrane and support pads.
PRELOADED AIR SAMPLING CASSETTES
General Features
• Supported filter types – MCE, PVC,
Polycarbonate, Glass Fibre, PTFE (with PP
support), PTFE (Zefluor) with PTFE support, PTFE
(pure, unsupported) and Quartz
• 25mm and 37mm diameter
• 2-piece Sytrene, 3-piece Styrene and Conductive
Polypropylene
• 50 per box
Configurations available to
conform with most NIOSH
standards that require filter
cassettes.
GRAVIMETRIC PRE-WEIGHED CASSETTES
General Features
• 2 or 3 piece housing styles
• Preloaded, ready to use
• Leak free construction eliminates sample loss
• Configurations available to conform with most NIOSH standards that require
filter cassettes
ENDOTOXIN-FREE CASSETTES
STERILE 37MM FILTER CASSETTES
Zefon Sterile Endotoxin-Free Cassettes are
specially manufactured to ensure there ist
no background interference when sampling
endotoxins. Each lot is carefully checked and
verified by independent laboratories for endotoxins
before product is released for shipment.
Zefon sterile 37mm filter cassettes are suitable for a
wide range of microbiological sampling and analysis
including fungi collection, water supply testing and
beverage monitoring. Each cassette is carefully
assembled in a clean room and then sterilized with
gamma radiation.
General Features
General Features
• 0.45µm Polycarbonate filter
• 37mm Styrene housing
• Sterilized by irradiation
• Endotoxin free
• 37mm 3pc stryrene housing
• Sterilized by gamma radiation
• MCE Filters in 0.8 or 0.45 micron pore size
• Polycarbonate Filters in 0.2 or 0.4 micron pore size
• 50 per box
Options
■■PS7345PCEFB CASSETTE
• 37mm 3pc 0.4μ Polycarbonate, sterile, 10/box
■■PS7345PCEFC CASSETTE
• 37mm 3pc 0.4μ Polycarbonate, sterile, 50/box
Options
■■WITH MCE FILTERS
■■WITH POLYCARBONATE FILTERS
GRAVIMETRIC MATCH-WEIGHED CASSETTES
Inlet
Collected
Particulate
Test Filter
Control Filter
Support Pad
Outlet
Gravimetric analysis samples require filters to
be weighed both before and after sampling to
determine the amount of contaminate collected.
Zefon pre-weighed cassettes eliminate the
inconvenience of pre-weighing filters by providing
the filter weight on each cassette prior to sampling.
Zefon match-weighed cassettes eliminate the need
to weigh filters before sampling by providing two
filters which are matched in weight. The top filter
collects particulate and the bottom filter serves as
a control. After sampling, both filters are weighed
and the difference in weight equals the amount of
contaminate collected.
General Features
Note: The use of match-weighed cassettes
overcome the environmental conditions issue as
both filters are exposed to the same environmental
conditions. Therefore, after sampling, the
measured weight difference is solely the amount of
contaminate collected.
• 2 or 3 piece housing
• Preloaded, ready to use
• Each cassette labelled with serial number
• Colour coded to indicate filter type
• 5 Decimal weight accuracy (.00001g)
• Use of Pure Homopolymer PVC filters provide
excellent weight stability
• PVC filters specially designed with no silica and
low ash properties
Options
■■7P52P CASSETTE
• 37mm, 2 pc, 5.0um
PVC Gravimetric Pre-weighed - Box of 50
■■7P53P CASSETTE
• 37mm, 3 pc, 5.0um
PVC Gravimetric Pre-weighed - Box of 50
10
General Features
• 2 or 3 piece housing
• Versions available with MCE (0.8um pore size) and
PVC (5.0um pore size) filters
• Labels with serial numbers provided
• Colour coded to indicated filter type and pore size
• Preloaded - ready to use
• Leak free design
Options
■■5M92M CASSETTE
• 25mm, 2 pc, 0.8um
MCE Gravimetric Matched - Box of 50
■■7M52P CASSETTE
• 37mm, 2 pc, 5.0um
PVC Gravimetric Matched - Box of 50
■■7M53P CASSETTE
• 37mm, 3 pc, 5.0um
PVC Gravimetric Matched - Box of 50
■■7M92M CASSETTE
• 37mm, 2 pc, 0.8um
MCE Gravimetric Matched - Box of 50
■■7M93M CASSETTE
• 37mm, 3 pc. 0.8um
MCE Gravimetric Matched - Box of 50
Environmental conditions can have a significant effect on filter weight
readings. When using Zefon pre-weighed cassettes, it is important that
the post sample weighing is performed under the same environmental
conditions used at the Zefon factory. Those conditions are set at a
temperature of 68° F (± 1.0°F) and a relative humidity of 50% (± 1%).
KENELEC.COM.AU / 1300 73 22 33
AIR SAMPLING
UNASSEMBLED AIR SAMPLING FILTER CASSETTES
Similar to the preloaded cassettes, Zefon also supply a full range of unassembled cassettes. This includes cassette housings, membrane filters and filter support pads.
All components are manufactured in-house to meet stringent quality standards.
CASSETTE HOUSINGS
Clear Styrene
Opaque Styrene
All unassembled cassette housings feature a leak free design and are
manufactured in-house to the same stringent quality standards that are applied
to pre-assembled cassettes.
General Features
• Leak free design
• Available in 25mm and 37mm sizes
• Available in 2-piece, 3-piece and 4-piece configurations
• Asbestos style (cone outlet) cassette housing also available
• Supplied in packs of 50
• Ideal for commercial laboratories that use high volume of cassettes
Asbestos Style
Options
■■CLEAR STYRENE
• The most common material, a crystal clear styrene that provide excellent
visibility inside the cassette housing.
■■OPAQUE STYRENE
• Manufactured of the same styrene the clear one is, except it is an opaque brown
colour to prevent transmission of light into the cassette.
■■POLYPROPYLENE (SOLVENT RESISTANT)
• A natural polypropylene with a cloudy looking colour. Material is resistant to a
wide range of chemicals.
■■CONDUCTIVE BLACK POLYPROPYLENE
• Manufactured using a polypropylene that is carbon filled making it static
conductive when grounded properly.
MEMBRANE FILTERS
FILTER SUPPORTS PADS
Options
MCE Filter
PVC Filter
Silver Filter
PCTE Filter
PTFE Filter
Glass Fibre
A full range of membrane filters is available from
Zefon. These are manufactured in-house to the
same stringent quality standards that are applied to
pre-assembled cassettes.
General Features
• Available in MCE, PVC, PCTE, Silver, PTFE and
Glass Fibre materials
• Pore sizes from 0.2um to 5.0um
• Available in 25mm, 37mm and 47mm sizes
• Majority supplied in packs of 100
KENELEC.COM.AU / 1300 73 22 33
■■MCE MEMBRANE FILTERS
• Mixed Cellulose Ester (MCE) Filter Membrane
Discs are manufactured from a mixture of
cellulose acetate and cellulose nitrate. MCE
membrane filters are one of the most widely
used filters in both air monitoring and analytical
applications.
■■PVC MEMBRANE FILTERS
• Polyvinyl Chloride (PVC) Membrane Filters (GLA5000) are excellent membrane filters for sampling
airborne metals, silica, and dust. Comprised
of inherently low ash pure homopolymer PVC,
these filters are particularly suited to provided
interference-free silica determinations. Low
moisture pick-up and low tare weight assure
gravimetric stability.
■■POLYCARBONATE MEMBRANE FILTERS
• Polycarbonate track-etch (PCTE) membrane
filters are manufactured from polycarbonate films.
They feature a smooth flat surface, exhibit wellcontrolled pore size and shape, and have very
low levels of extractables. Naturally hydrophobic.
■■SILVER MEMBRANE FILTERS
• Silver Metal Filter Membranes are pure metallic
silver (99.97% pure silver) and are available with
particle retention ratings of 0.45 or 0.8 microns.
Silver metal membranes are used in a variety of
filtration applications, and their ability to withstand
extreme chemical and thermal stress makes them
ideal for applications involving aggressive fluids
and/or high temperatures.
■■PTFE MEMBRANE FILTERS
• PTFE membrane filters provide excellent
chemical resistance and are suitable for use in
the most aggressive sampling environments.
■■GLASS FIBRE FILTERS
• Zefon glass microfiber filters are produced from
100% borosilicate glass microfiber without the
use of binders or strengthening agents. The
fibers used to manufacture these depth filters
are smooth and uniform. This permits their
characteristically high flow rates while allowing
retention of exceptionally small particles and
high load capacity. These characteristics are
particularly important in applications involving
high concentrations of particulate.
Zefon manufacture a range of filter support
pads. These filter supports are used behind filter
membranes to support them from collapsing while
still allowing free air flow through them.
General Features
• Available in cellulose, porous plastic and stainless
steel grids
• Available in 25mm and 37mm sizes, stainless
steel grid also available in 47mm size
• Supplied in packs of 100, stainless steel filter
supports are sold as individual units
Options
■■CELLULOSE
• Cellulose pads are made up of 100% pure
cellulose and the most common support used in
filter cassettes.
■■POROUS PLASTIC
• Porous plastic supports work well when sampling
chemicals that are not compatible with cellulose.
■■STAINLESS STEEL GRIDS
• Stainless steel grids can be used in a wide range
of filter holders and can easily be cleaned and
re-used.
11
AIR SAMPLING
DUSTTRAK - AEROSOL MASS CONCENTRATION MEASUREMENT
DustTrak: Real-Time, Laser based monitors for OHS professionals.
The DustTrak measures aerosol contaminants such as dust, smoke, fumes and mists, giving you real-time aerosol mass readings.
You can measure PM1, PM2.5, PM4 & PM10 one at a time or simultaneously depending on the model.
TSI 8532 DUSTTRAK II PORTABLE DUST MONITOR
TSI 8530 DUSTTRAK II PORTABLE DUST MONITOR
RENT
ME
RENT
ME
Measures PM
fractions one at
a time
Measures PM
fractions one at
a time
General Features
General Features
• 100nm to 10μm particle size range
• 1ug/m3 to 400mg/m3 dust concentration range
• 6600mA rechargeable lithium ion battery
• 37mm filter sample collection capabilities
• Large VGA 5.7” colour touch screen
• Measures all PM fractions (one at a time)
• 66,000 point data logging & software
• 100nm to 10μm particle size range
• 1ug/m3 to 400mg/m3 dust concentration range
• 3600mA rechargeable lithium ion battery
• 66,000 point data logging & software
• Large VGA colour graphical display
• Packed full of popular features
TSI 8534 DUSTTRAK PORTABLE DUST MONITOR
TSI 8533 DUSTTRAK PORTABLE DUST MONITOR
RENT
ME
Measures
PM fractions
simultaneously
RENT
ME
Measures
PM fractions
simultaneously
General Features
General Features
• 100nm to 15μm particle size range
• 1ug/m3 to 150mg/m3 dust concentration range
• 3600mA rechargeable lithium ion battery
• 66,000 point data logging & software
• Measures all PM fractions (simultaneously)
• Large VGA colour graphical display
• Packed full of popular features
• 2 year warranty
• 100nm to 15μm particle size range
• 1ug/m3 to 150mg/m3 dust concentration range
• 6600mA rechargeable lithium ion battery
• 37mm filter sample collection capabilities
• Large VGA 5.7” colour touch screen
• Measures all PM fractions (simultaneously)
• 66,000 point data logging & software
12
KENELEC.COM.AU / 1300 73 22 33
AIR SAMPLING
PARTICLE COUNTING
Detecting the root cause of complaints can often come down to being able to find and measure the presence of a pollutant
- signal by the level of particles in a particular area.
TSI 8525 P-TRAK REAL-TIME ULTRAFINE
PARTICLE COUNTER
TSI 3007 ULTRA-FINE PARTICLE COUNTER
TSI 9306 PORTABLE PARTICLE COUNTER
RENT
ME
RENT
ME*
General Features
General Features
General Features
• 2 nm to 1μm wide particle size range
• Ideal for indoor air quality and OH&S applications
• Terrific in detecting combustible aerosol sources
• Sample Flow Rate - 100 cm3/min
• Concentration Range - 0 to 5 x 105 particles/cm3
• Audible and visual particle detection alerts
• Fully serviced and supported in Australia
• 2 year warranty
• 10nm to 1μm wide particle size range
• Ideal for indoor air and OH&S work
• Menu driven, easy to use
• USB interface, data logging and software
• Audible and visual particle detection alerts
• Packed full of other features
• 0.3μm to 25μm particle size range
• 2.8 lpm flow rate with built-in pump
• 10,000 point data logging with software included
• USB & Ethernet interfaces, HEPA filtered output
• Colour LCD display, 6 hour lithium ion battery
• 2 year warranty
Options
■■TSI 9306-03
These particle counters are calibrated with NIST traceable PSL spheres
using TSI’s world-class Classifier and Condensation Particle Counters, the
recognized standard for particle measurements. Backed with a standard
two-year warranty and TSI’s long-standing reputation for high quality, there
are no other handheld particle counters like it on the market today.
• 6 Fixed size channels with the channels set at 0.3μm,
0.3μm, 0.5μm, 7μm, 1.0μm, 2.0μm & 5.0μm
■■TSI 9306-04
• 6 Fixed size channels with the channels set at
0.3μm, 0.5μm, 1.0μm, 3.0μm, 5.0μm & 10μm
■■TSI 9306-V2* (RENT ME)
• 6 user selectable size channels from 0.3μm to 10μm
NANOPARTICLE SURFACE AREA MONITOR
TSI 3550
Recent research has shown that the surface area
of nanoparticles is highly correlated to exposure
related adverse health effects. The Model
3550 indicates the surface area of nanoparticle
aerosols that deposit in the lung. The reported
measurements correspond to the ICRP lung
deposition curves for the tracheobronchial (TB) and
alveolar (A) regions of the human respiratory tract.
General Features
• Selectable measurement modes for
tracheobronchial (TB) or alveolar (A) deposition
response
• Comprehensive software for collection, storage,
and display of running-average, time-weightedaverage (8-hour), or total deposited surface area
• Simple operation, fast set up, and the ability
to run continuously for unattended, long-term
exposure monitoring
• Sensitivity down to 10 nm
• Over five decades of concentration, from 0 to
10,000 μm2/cm3 spanning a wide range of
exposure dosages
• Data rate of one measurement per second
detects short periods of high-intensity exposures
KENELEC.COM.AU / 1300 73 22 33
13
ASBESTOS
ABATEMENT SAMPLING PUMPS
BUCK LIBRA L4 ABATEMENT SAMPLING PUMP
The Buck LIBRA™ is a low cost, high performance, CONSTANT FLOW personal sampling pump. Designed for use
with asbestos and lead abatement, the LIBRA provides full constant flow compensation using 25mm and 37mm
cassettes.
With a rugged, compact design, the sealed pump case protects the internal components from dust, fibers and
moisture. Includes a rechargeable NiMH battery with available one-hour charger. Easy to operate with “Set it and
Forget it” flows at 2.0, 2.5 & 3.0 LPM; maintained within ±5% for full constant flow compensation using 37 and
25mm cassettes interchangeably, ensuring accurate sample volumes based on the run time. The BUCK Libra™ L-4
is capable of delivering up to 4.0 LPM for periods exceeding 8 hours. Bright LED’s indicate the pump is ON, Flow
Fault or a Low Battery. Flow from 5 to 800 cc/min may be obtained using optional Low Flow Holder.
General Features
Options
• Compact, rugged and quiet
• No tools required to change flow rates
• Flow setting is saved in memory for next day quick
start
• Battery pack rechargeable while attached or
separately
• Stainless steel belt clip with built-in tripod connector
• One-hour rechargeable batteries and extended run
triple packs
• High impact steel fiber filled Lexan case, antistatic
and RFI shielded
• “Auto-restart” within one minute of a flow fault
• Flows up to 4 LPM for special cyclone requirements
• Low flows, 5 to 800 cc/m, with optional Universal
Low Flow Sorbent Tube Holder
• High backpressure capable for 25mm 0.45μ micron
asbestos filters
• Built in washable stainless steel 100 micron filter for
economy of use
• One year warranty
■■APB-926020
• Pump with charger
■■APB-942600
• Pumps 5 pack with 5 charger station and a
durable hard plastic 1500 Pelican case
■■APB-109030
• Adjustable universal low flow holder
Zefon high volume diaphragm area sampling pumps
are economical workhorses. Each pump comes
with a locking flow control valve, hose barb, 10’
tubing and on/off switch. Suitable for sampling a
large area, for example a room.
Accessories
AREA SAMPLING PUMPS
General Features
High Volume Diaphragm Pump
• Ultra high volume 23 stroke diaphragm pump
• Includes flow control valve and tubing
• Suitable for use with Air-O-Cell Cassettes, PCM
and TEM Cassettes
• Available as a single pump or a 2 pump kit. The
2 pump kit includes 2 pumps, 2 sampling stands,
tubing and a heavy duty carrying case
■■ZA0042 - STAND, CASSETTE, ECONOMY
■■ASB-1 - STAND, CASSETTE, DELUXE
■■ZA0005 – ADAPTER, LUER, PLASTIC
• Use to attach cassette to ¼” tubing, 10/PK
■■459743 - COUPLER, METAL LUER
• Use to attach cassette to ¼” tubing, 3/PK
■■ZA0064 - TUBING
• Tygon 1/4” ID, 50 feet
Options
■■ZTHV01-220V
• Pump, Zefon Diaphragm, 220VAC
■■ZTHV01-KIT-220V KIT
• Zefon Diaphragm 2 Pump Kit, 220VAC
2 Pump Kit
FIELD ROTAMETER CALIBRATOR FOR SAMPLING PUMPS
Zefon Field Rotameters are a low cost way to
measure airflow in air sampling applications. They
feature a durable acrylic housing with direct reading
scales printed on them. These are available in
three different flow ranges covering a range of 0.2
through 30 LPM. Operation and maintenance are
very simple; only a few common sense precautions
must be observed to assure long, trouble-free
service.
Options
■■116116 - ROTAMETER, 0.2-4 LPM
■■195380 - ROTAMETER, 1-20 LPM
■■195505 - ROTAMETER, 3-30 LPM
Each flowmeter is supplied with 1 hose barb,
tubing, and luer connecter.
14
KENELEC.COM.AU / 1300 73 22 33
ASBESTOS
ASBESTOS SAMPLING CASSETTES & ACCESSORIES
ASBESTOS 25MM AIR SAMPLING CASSETTES
ASBESTOS BULK SAMPLING EQUIPMENT
Zefon Cutter Sleeve
Zefon T-Handle
Zefon PCM & TEM 25mm air sampling cassettes are designed and manufactured
to meet all applicable NIOSH, OSHA, and EPA standards. The cassette housings
are injection moulded in-house and are individually assembled and preloaded
under stringent quality control standards. Once assembled, each cassette is
individually tested prior to packaging for shipment. Random lot sample testing
is performed daily by an independent laboratory to ensure low background fibre
counts. Laboratory results are available upon request.
General Features
• Quality 0.8um MCE filter material with or without grids (PCM models)
• Quality 0.45um + 5.0um MCE filter material (TEM models)
• 2” Static conductive extension cowl
• Meets NIOSH 7400/7402 specifications
• Meets AEHRA requirements (TEM model)
• Each cassette is marked with a unique serial number
• Preloaded - ready to use
Options
■■Z008BA - CASSETTE
• 25mm, 3 pc, 0.8um, MCE (Box of 50)
■■Z008GA - CASSETTE
• 25mm, 3 pc, 0.8um, MCE with grid (Box of 50)
■■Z008GGA - CASSETTE
• 25mm, 3 pc, 0.8um MCE with green grid (Box of 50)
■■Z012BS - CASSETTE
• 25mm, 3 pc, 1.2um, MCE, with white shrink band (Box of 50)
■■Z012GS - CASSETTE
• 25mm, 3 pc, 1.2um, MCE with grid with white shrink band (Box of 50)
■■Z045BA - CASSETTE
• 25mm, 3 pc, .45um & 5.0um MCE (Box of 50)
■■Z008PC - CASSETTE
• 25mm, 3 pc, 0.8um polycarbonate (Box of 50)
Zefon provide their own cutter sleeves and handles for asbestos bulk sampling.
The 3” Steel Sampling Modules (cutter sleeves) are extremely strong and
durable. They are more robust than similar modules manufactured from copper.
Compatible with the Zefon solid aluminium T handle or the EMS T handle.
In addition, the Wonder Makers Asbestos Bulk Sampling set is a great option.
This is the safest, most efficient way to collect bulk samples and project a
professional image. It makes the way inspectors have been taking samples
obsolete. This small compact device uses individual cutter sleeves in airtight
transport containers for maximum safety and accuracy.
General Features (Wonder Makers WM10)
• Includes rugged carrying case with fold-down handle and positive grip latch,
two handles, two plungers, and 100 cutter sleeves in clear slim vials with caps
• Eliminates cross-contamination
• Easy to operate
• Ends the need for protective equipment during sampling
• Encourages full-depth samples
• Complies with OSHA asbestos regulations
• Also available in a double-length set without case – WM11
Options
Zefon Asbestos Bulk Sampling
■■ZA0070
• Asbestos bulk sampling modules (cutter sleeve), 3” length, case of 100
■■ZA0071 - ZEFON T-HANDLE, SOLID ALUMINUM
Wonder Makers Asbestos Bulk Sampling
■■WM10 - BULK SAMPLING STARTER SET
■■WM11 - DOUBLE LENGTH BULK SAMPLING STARTER SET
• Without case
ACETONE VAPORIZERS
PERM-O-FIX ACETONE VAPORIZER
The ZA0191 is a simple, easy to use, acetone vaporizer for use in preparing
asbestos PCM samples as per NIOSH 7400. Includes vaporizer only. Available in
120VAC and 220VAC models.
Options
■■ZA0191 - PERM-O-FIX ACETONE VAPORIZER, 230VAC
SMALL WONDER ACETONE VAPORIZER
The Small Wonder Acetone Vaporizer Kit includes everything needed to clear
slides for PCM analysis.
General Features
• Small Wonder acetone vaporizer with built-in heat control, temperature gauge,
and cool cover; 2 oz. acetone; 1/2 oz. triacetin; 1/2 gross microscope slides;
cover slips; tweezers; microdropper; syringe; #10 round blade scalpel; pre-cut
foam padding; durable plastic carrying case with handle; instruction manual
• Padded carrying case protects equipment and supplies
• Detailed instruction manual
• Enough supplies for the analysis of 1/2 gross of slides
• Lightweight but solidly built
• Designed in strict compliance with the NIOSH 7400, 7402, or ORM
requirements for preparation of microscope slides for PCM analysis
Options
■■WM42 - SMALL WONDER ANALYSIS KIT
KENELEC.COM.AU / 1300 73 22 33
15
MICROBIAL SAMPLING
BIO PUMP SAMPLING
ZEFON BIO PUMP PLUS
Ideal for indoor air quality sampling, mould
spores, bio aerosols, pollen, fibres and inorganic
particulates.
The Zefon Bio-Pump® Plus is the smallest and
lightest portable battery powered IAQ sampling
pump available. It provides the simplest and most
convenient way to sample with Air-O-Cell® and ViaCell® cassettes at a flow rate of 15LPM.
General Features
• Extra long battery life - Take over 100 samples on a
single charge
• Programmable timer allows unattended operation
• Quick-charge battery charger included (approx 3
hours)
• Nothing to prepare or clean. Just place the cassette
on the pump, set the time and go
• Each pump comes complete with both an Air-OCell® and Via-Cell® flow indicator, quick charger,
10 free Air-O-Cell® cassettes and a handy carrying
case
Options
■■ZBP-200
• Bio Pump Plus with 230 VAC charger
■■ZBP-200-CKIT
• Bio Pump Plus with TSI Calibrator
Acessories
■■BIO PUMP REMOTE EXTENSION TUBE ■■FILTER, BIO PUMP BIOISOLATION ■■TRIPOD STAND - HEAVY DUTY
SAMPLING CASSETTES AND MEDIA FOR BIO PUMP
Zefon manufactures a complete Family of IAQ sampling cassettes to meet demanding situations
AIR-O-CELL CASSETTES
VIA-CELL SAMPLING CASSETTES
Optical microscopy
Air-O-Cell sets the standard for particle capture and
optical analysis.
General Features
• The ultimate multipurpose cassette for:
• Bio aerosols: mould spores, pollen, insect
parts, skin cell fragments, asbestos, fibreglass,
cellulose, clothing fibres, synthetics, IAQ
sampling
• Inorganic particulate: ceramic, fly ash, copy
toner, oil droplets, paints, rust, salts, products of
combustion
Options
■■AOC010 - BOX OF 10
■■AOC050 - BOX OF 50
16
AIR-O-CELL CSI CASSETTES
Culture and PCR
The Via-Cell® bioaerosol sampling cassette is
designed to collect both viable and non-viable
bioaerosols, maintain viability of the viable mold
spores and prevent growth during transport to
the laboratory. Sampling with the Via-Cell® is very
similar to its sister product Air-O-Cell®. Simply
connect it to any pump calibrated to 15LPM and
run your sample. The key to the Via-Cell® is that
the media used for collection maintains viability
of spores and allows several analysis options
including culturing, PCR analysis and microscopy.
Options
■■VIA010 - BOX OF 10
Optical, SEM & X-Ray analysis
Air-O-Cell CSI brings the advantages and precision
of SEM particle analysis with x-ray chemical
analysis to indoor air quality investigations.
General Features
• Samples can be tested and re-tested using
optical, scanning electron microscopy (SEM) and
x-ray analysis in any order without significant
particle loss or complex sample preparation
• Applications include indoor air quality, home
inspection, floor inspection, stack emissions,
allergy testing, clean room monitoring and fibre
analysis
Options
■■CSI010 - BOX OF 10
KENELEC.COM.AU / 1300 73 22 33
MICROBIAL SAMPLING
OTHER SAMPLING TECHNOLOGIES
BIO-TAPETM
TEDLAR GAS SAMPLING BAGS
Bio-Tape™ provides a standardized surface sampling method used for
the determination of possible microbial, bioaerosol, and inorganic dust
contamination. Quickly take a sample and measure the relative degree
of contamination. It is especially useful when sampling valuable or nontransportable materials and is very effective on smooth areas.
Bio-Tape consists of a flexible plastic microscope slide with a pre-defined
adhesive area. A center-line marker on the slide aids the user in locating the
center when taking the sample and also aids the laboratory analyst. Each slide is
provided with a unique serial number for traceability and packed in a slide mailer
to prevent cross contamination.
Bio-Tape is compatible with both optical microscopy and scanning electron
microscopy (SEM). This provides the ability to perform optical and SEM analysis
along with an x-ray analysis on the exact same air surface sample and exact same
particles.
General Features
• Provides sample consistency
• Individually serialized for traceability
• Prevents cross contamination
• Requires less laboratory prep time
• Eliminates problems of placing tape in a zip bag, or broken glass slides
• Samples may be archived by the laboratory for later review
Options
■■BT0025 SLIDES - 25 IN A BOX
■■BT0050 SLIDES - 50 IN A BOX
■■BT0500 SLIDES - 500 IN A BOX
Gas sample bags, usually called Tedlar Bags, are a convenient way to collect
gas and vapour samples in air. Many chemical hazards can be effectively
collected by sample bags, allowing easy transport to the laboratory for testing.
Zefon EconoGrab™ gas sampling bags are excellent quality, low-cost tedlar® gas
sampling bags that feature a choice of a single polypropylene fittings or stainless
steel fitting.
General Features
• Chemically inert Tedlar® film
• Reusable if purged with nitrogen
• Easy storage and handling
Applications
• Grab sampling
• Indoor air sampling
• Gas blending
• Assessing exposures from leaks and spills
• Leaky underground storage tanks
• Sampling from vents or flues
• Hazardous waste site sampling
• Measuring anesthetic gases in operating rooms
• Stack sampling
• Soil gas sampling
• Calibration gas standards
• Ground water testing
Options
EconoGrab™ Tedlar bags come with a choice of a single polypropylene fittings
(suitable for use in most applications) or stainless steel fitting (for use when
sampling compounds that are not chemically inert to polypropylene.)
Using Bio-Tape™ helps provide more consistency
in your samples. This is because each sample uses
the same amount of adhesive surface area and
the provided packaging offers protection during
shipment to the laboratory. When the laboratory
receives your sample, there will be no guessing
where the sample area is and no sticky mess of tape
to deal with.
■■0.5 L
■■1.0 L
■■3.0 L
■■5.0 L
■■10.0 L
■■25 L
■■50 L
■■100 L
BUCK BIO CULTURE MICROBIAL AIR SAMPLER
The Bio-Culture™ air sampler is the smallest, most
cost effective and easiest to use sampler available
for microbial air sampling. The Bio-Culture™ air
sampler features a selectable, continuous, constant
sample flowrate and is simple to operate. No tools
are required. Its quiet operation allows unobtrusive
sampling in a variety of applications. Selecting the
appropriate air sampling device is an important step
in preserving the quality of your work environment.
Think carefully about your workflows and consider
all features of a microbial air sampler to ensure you
receive a product that delivers what you require
without compromising your environment.
General Features
Options
■■BIO-CULTURE CALIBRATION HEAD • The Bio-Culture™ calibration head is a NIST
traceable venturi calibrator within 1% accuracy
that allows users to calibrate the flow of the BioCulture pump themselves without having to send
the pump out for service or calibration.
• Allows flow calibration at flow rates between
30-120LPM
• Designed for use with impeller fan type pumps
like the Bio-Culture, which require calibration
devices with very little backpressure resistance
• Provided with a certificate of calibration traceable
to NIST standards
• Flow rate - 30-120LPM (user adjustable)
• Uses standard 90mm petri dishes
• Sampling head design of 380 1mm diameter holes
• Battery powered - runs for 6-8 hours (depending on
flow rate, battery maintenance and backpressure)
• Tripod mounting threads on bottom of unit - allows
90 degree sampling
• Sampling head may be sterilized by autoclave or
gas torch
• Built-in timers of 1, 2, 5, and 10 minutes
• Optional calibration head allows field calibration of
flow rate with a NIST traceable calibrator
KENELEC.COM.AU / 1300 73 22 33
17
INDOOR AIR QUALITY & GAS MONITORING
INDOOR AIR QUALITY
Providing a comfortable, safe and healthy indoor environment is an increasingly important concern. Good indoor air quality increases concentration and productivity
which can reduce lost days due to absence. A good indicator of proper ventilation is the level of CO2 present in a space. Carbon dioxide is a normal by-product of
occupant respiration. Elevated levels of CO2 may indicate that additional dilution ventilation is required.
TSI 7515/7525/7545 IAQ-CALC METERS
TSI IAQ-Calc™ Meters are outstanding instruments
for investigating and monitoring indoor air quality
(IAQ). Handheld, easy to use allowing you to gather
your data and work with ease.
CO2
General Features
CO
• Conduct IAQ evaluations
• Determine thermal comfort
• Examine building IAQ conditions to optimize
worker productivity
• Comply with regulations and guidelines
• Model 7515 is a cost-effective meter for carbon
dioxide (CO2) measurements.
• Models 7525 and 7545 simultaneously measure
and data log multiple parameters. Model 7525
measures CO2, temperature, humidity, and
calculates dew point, wet bulb temperature, and
percentage outside air.
• Model 7545 adds detection of carbon monoxide
(CO).
Temperature
✓
✓
Humidity
✓
✓
Percentage outside air
✓
✓
Dew point
✓
✓
Wet bulb temperature
✓
✓
Data logging/
downloading
✓
✓
✓
✓
✓
✓
✓
✓
Options
■■TSI 7515
• CO2 & statistics display
■■TSI 7525
• CO2, temp, humidity, data logging
■■TSI 7545
• CO2, temp, humidity, CO, data logging
7515
7525
✓
✓
✓
✓
✓
Statistics
Review data
Certificate of Calibration
✓
7545
✓
Available
Unavailable
TSI 7575 PLUG AND PLAY MULTIFUNCTION IAQ MONITOR
TSI’s Q-Trak™ IAQ Monitor is a handheld,
multi-function test instrument which features a
menu-driven user interface for easy operation and
provides quick, accurate information to measure
and assess key IAQ parameters.
TSI 7575
PLUG AND PLAY MODEL
The TSI 7575 offers outstanding versatility with its
“plug and play’ feature – simply change the probe
over to suit the monitoring you are doing.
CHOOSE THE PROBES
THAT SUIT YOU
The standard 7575 monitor comes with the 982
Probe – right from the beginning you’re all set
to measure temperature, humidity, CO2 and CO.
If you need to do other measurements such as
VOCs switch over to one of the other optional VOC
probes.
General Features
• One instrument with multiple plug-in probe
options including VOCs and air velocity
• Simultaneously measures CO2, CO, temperature
and humidity with 982 probe
• Displays up to 5 measurements
• On-screen messages and instructions
• Store up to 39 days of data collected at oneminute log intervals
• TrakPro™ Data Analysis Software provided for
data logging, analysis and documenting results
• Bluetooth communications for transferring data
or remote polling keypad lockout to prevent
tampering during unattended use
RENT
ME
18
Options
■■7575 MULTI FUNCTION METER
• Including 982 Probe
■■7575-X MULTI-FUNCTION
• IAQ meter only, no plug-in probes
Probes
■■980 IAQ PROBE
• CO2, temperature, humidity
■■982 IAQ PROBE
• CO2, temperature, humidity, CO
■■960 AIR VELOCITY PROBE
• Velocity, temperature
■■962 AIR VELOCITY PROBE
• Velocity, tempearture (articulated)
■■964 AIR VELOCITY PROBE
• Velocity temperature, humidity
■■966 AIR VELOCITY PROBE
• Velocity, temperature, humidity (articulated)
■■984 VOC PROBE
• 10-20000 PPB, temperature
■■985 VOC PROBE
• 1-2000 PPM, temperature
■■986 IAQ PROBE
• VOC 10-20000 PPB, CO2, temperature, humidity
■■987 IAQ PROBE
• VOC 1-2000 PPM, CO2, temperature, humidity
■■995 ROTATING VANE PROBE
• 100 mm, velocity, temperature
■■792 SURFACE TEMPERATURE PROBE
■■794 AIR TEMPERATURE PROBE
■■800681 IAQ PROBE STAND
KENELEC.COM.AU / 1300 73 22 33
INDOOR AIR QUALITY & GAS MONITORING
PORTABLE GAS MONITORS
YESAIR 8 CHANNEL PORTABLE IAQ MONITOR
YES PLUS LGA 15 CHANNEL IAQ MONITOR
General Features
General Features
• Measures temperature & humidity standard
• Plug in up to 5 other gas sensors anytime
• Up to 26 other sensors to choose from
• 1 million point data logging with software
• Highly accurate 12 bit resolution results
• Includes a built-in sample draw pump
• Measures temperature & humidity standard
• Plug in up to 12 other gas sensors anytime
• 26 popular sensors to choose from
• 1 million point data logging with software
• Highly accurate 12 bit resolution results
• Sample using internal pump or by diffusion
Options
■■CARBON MONOXIDE (CO) SENSOR (0 - 50 PPM)
■■CARBON MONOXIDE (CO) SENSOR (0 - 50 PPM)
• H2 compensated for use in H2 background
■■NITROGEN DIOXIDE (NO2) SENSOR (0 - 5 PPM)
■■NITRIC OXIDE (NO) SENSOR (0 - 100 PPM)
■■ETHYLENE (C2H4) SENSOR (0 - 500 PPM)
■■ETHYLENE OXIDE (C2H4O) SENSOR (0 - 20 PPM)
■■OXYGEN (O2) SENSOR (0 - 25% VOLUME)
■■OZONE (O3) SENSOR (0 - 1 PPM)
■■AMMONIA (NH3) SENSOR (0 - 50 PPM)
■■CHLORINE (CL2) SENSOR (0 - 5 PPM)
■■CHLORINE DIOXIDE (CLO2) SENSOR (0 - 1 PPM)
■■HYDROGEN (H2) SENSOR (0 - 1,000 PPM)
■■HYDROGEN SULPHIDE (H2S) SENSOR (0 - 50 PPM)
■■HYDROGEN CHLORIDE (HCL) SENSOR (0 - 30 PPM)
■■HYDROGEN CYANIDE (HCN) SENSOR (0 - 100 PPM)
■■HYDROGEN FLUORIDE (HF) SENSOR (0 - 10 PPM)
■■SULPHUR DIOXIDE (SO2) SENSOR (0 - 20 PPM)
■■FORMALDEHYDE (CH2O) SENSOR (0 - 10 PPM)
■■ARSINE (AsH3) SENSOR (0 - 2 PPM)
■■FLUORINE (F2) SENSOR (0 - 2 PPM)
■■PHOSPHINE (PH3) SENSOR (0 - 1 PPM)
■■SILANE (SiH4) SENSOR (0 - 1 PPM)
KENELEC.COM.AU / 1300 73 22 33
Infrared Sensor
■■CARBON DIOXIDE (CO2) SENSOR (0 - 5,000 PPM)
■■CARBON DIOXIDE (CO2) SENSOR (0 - 10,000 PPM)
■■CARBON DIOXIDE (CO2) SENSOR (0 - 20% VOLUME)
■■CARBON DIOXIDE (CO2) SENSOR (0 - 5% VOLUME)
■■CARBON DIOXIDE (CO2) SENSOR (0 - 100% VOLUME)
Catalytic Sensor
■■COMBUSTIBLE GAS (e.g. CH4, H2, C3H8) SENSOR (0 - 100% LEL)
•Please specify at time of order
PID Sensor
■■TVOC SENSOR (0 - 300 PPM)
■■TVOC SENSOR (0 - 30 PPM)
19
INDOOR AIR QUALITY & GAS MONITORING
GAS DETECTION CONTROLLERS - CONNECT THE SENSOR YOU NEED
PDC MULTI-CHANNEL CONTROLLER
DST DIGITAL TRANSMITTER
GEM-II ANALOG MULTI PURPOSE
TRANSMITTER
INCORPORATES
“SMART” SENSOR
TECHNOLOGY
General Features
General Features
General Features
• For up to 8 analog transmitters and up to 120
digital transmitters.
• Up to 32 channels on base controller, expandable
to 128 channels
• RS485 communication with digital transmitters
• Eight 5-amp SPDT relays
• Optional analog inputs (up to eight)
• Optional BACnet® output module
• Audible & visual alarms
• LCD Display
• Optional Watertight enclosure
• Detects a wide range of gases, including solid
state and electrochemical
• Designed for use with the PDC controller
• RS485 digital output signal
• RoHS compliant circuit boards
• Configured for four wire multidrop wiring
• Thermal resetting fuse
• LED indication for Power, Fail and Alarm
• Single or dual channel
• Two 5-amp SPDT relays
• Integral plug-and-play “smart” sensors or remote
sensors
• 4-20mA linear output signal
• Analog Transmitter
• CSA, UL & C-Tick certification
• LED light indicators
• Optional 4 digit display
• Optional Water tight enclosure
GEM MRI OXYGEN SAMPLING TRANSMITTER
PET BACNET DIGITAL TRANSMITTER
LPT LOW POWER TRANSMITTER
INTEGRATE
TO YOUR
BUILDING
MANAGEMENT
SYSTEM
GEM-MRI is a self-contained oxygen (O2)
monitoring system developed for Magnetic
Resonance Imaging (MRI) room applications for
hospitals and clinics.
General Features
General Features
General Features
• Digital transmitter
• Single or dual gas sensor
• Includes temperature sensor
• Tri-color LED light indicator
• Communicates via BACnet protocol MS/TP.
• Thermal resetting fuse
• Analog transmitter
• Single sensor: carbon monoxide (CO) 0-200 PPM
or nitrogen dioxide (NO2) 0-10 PPM
• Linear 4-20 mA output
• 2-wire loop, 3-wire VDC or 4-wire VAC power
• Automated calibration
• Easy installation
AST-I INDUSTRIAL ANALOG TRANSMITTER
• Sample draw pump
• Two 5-amp SPDT relay
• Dry contact relays for control of remote devices
• Analog output (4-20mA)
• Audible alarm
• Adjustable flow meter
LPT-A LOW POWER TRANSMITTER WITH LCD
LOW POWER,
LOW COST WIDE
RANGE OF GAS
SENSORS
General Features
• Analog transmitter
• Single Sensor; supports a wide range of sensors
including electro-chemical, solid state and
catalytic (refer to table)
• 3-wire VDC or 4-wire VAC power
• 24 volt DC or AC power (nominal)
• Linear 4-20mA or 0-10 volt output signal
• Graphic LCD display (user selectable function)
• 1 dry contact relay, 30 volt 2 amp maximum
• Standard water/dust tight, corrosion enclosure
(drip proof)
• Audible alarm
• Automated calibration procedure
• Optional splash guard, heater, and logger
20
LOW POWER,
LOW COST –
GREAT FOR BULK
PURCHASES!
AST-IS STANDARD CO2 TRANSMITTER
AESTHETIC
HOUSING
FOR OFFICE &
RESIDENTIAL
USE.
INFRARED
GAS
DETECTORS
General Features
General Features
• Dual temperature compensated pyroelectric
infrared detectors
• Lower power consumption
• Target gases include CO2 (0-5, 0-20,0-100%) and
Methane CH4 (0-100% of volume or 0-100% LEL)
• Water/dust tight/corrosion resistant polycarbonate
enclosure
• Linear 4-20mA output
• Measurement ranges from 0-1000 PPM
• Attractive PVC enclosures ideal for indoor use eg,
residential, schools & offices
• Linear 4-20mA or 0-10VDC output
• Single internal infrared CO2 sensor, 0 - 2,000 ppm
• Optional LCD Display
• Optional temperature display
• Optional audible alarm
• Optional relay
AST-IS INDUSTRIAL CO2 TRANSMITTER
ART INFRARED REFRIGERANT TRANSMITTER
CHILLER ROOM
OR FREEZER
OPTION
INFRARED CO2
DETECTOR
General Features
General Features
• Duct Mount option in IP54 enclosure, Wall Mount
option in IP65 enclosure
• Linear 4-20mA or 0-10VDC output
• Single internal infrared CO2 sensor, 0 - 2,000 ppm
OR 0-4%
• Optional LCD Display
• Optional relay
• Use accurate infrared sensors
• Detect a wide range of refrigerants
• Audible & visible alarms
• Standalone or connect to BMS
KENELEC.COM.AU / 1300 73 22 33
INDOOR AIR QUALITY & GAS MONITORING
CHOOSE YOUR SENSOR FOR YOUR TRANSMITTER
CALL KENELEC FOR ASSISTANCE
Ensure that all required products are included to make a complete system e.g:
✓
Available
Unavailable
G
EM
G -I
as I M
D u
et lti
ec -P
to ur
r po
G
se
EM
Sa M
m R
pl I O
in x
g yg
Sy e
st n (
PE
em O
2 )
T
Tr BA
an C
sm ne
itt t ®
er
AS
T
Tr -I I
an nd
sm us
itt tria
er l
An
al
AS
og
T(C IS
O C
2) a
Tr rbo
an n
sm D
itt iox
AR
er ide
T
Tr In
an fr
sm are
itt d R
er e
LP
fr
ig
T
er
Tr Lo
an
an w
t
sm P
o
itt w
er er
LP
T
Po -A
w An
er al
Tr og
an ue
sm L
D
itt ow
ST
er
Tr D
an ig
sm ita
itt l
er
• LPT and LPT-A transmitters work with PDC Controllers
• DST transmitters work only with PDC controllers
• PET transmitters work with BACnet control devices
Sensors
✓
✓
Ammonia (NH3)
Carbon monoxide (CO)
✓
Carbon Dioxide (CO2)
Chlorine (Cl2)
✓
✓
✓
✓
Ethylene (C2H4)
Ethylene oxide (C2H4O)
✓
✓
Formaldehyde (CH2O)
Hydrogen (H2)
Hydrogen sulphide (H2S)
Hydrogen chloride (HCl)
Hydrogen cyanide (HCN)
Methane (CH4)
Nitrogen dioxide (NO2)
Nitric oxide (NO)
Oxygen (O2)
✓
✓
✓
✓
✓
✓
✓
✓
✓
Ozone (O3)
Phosphine (PH3)
Silane (SiH4)
Sulphur dioxide (SO2)
Combustibles
Solid State / Semi-Conductor Sensor
✓
✓
✓
✓
0-2000ppm
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
0-1032ppm
0-2000ppm
✓
✓
✓
✓
Refrigerant (R11)
Refrigerant (R12)
Refrigerant (R22)
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Refrigerant (R114)
Refrigerant (R123)
Refrigerant (R134A)
Refrigerant (R401A)
Refrigerant (R401B)
Refrigerant (R402A)
Refrigerant (R404A)
Refrigerant (R407C)
Refrigerant (R408A)
Refrigerant (R409A)
Refrigerant (R410A)
Refrigerant (R422A)
Refrigerant (R422D)
✓
Refrigerant (R500)
Refrigerant (R502)
Refrigerant (R507)
Refrigerant (R507A)
TVOC (0-500ppm)
Catalytic Sensor
Hydrogen (H2)
Methane (CH4)
Propane (C3H8)
KENELEC.COM.AU / 1300 73 22 33
21
HOSPITALS & LABS
PRESSURA ROOM PRESSURE PRODUCTS
TSI PRESSURATM
Monitor and change high & low pressure rooms
TSI PresSura™ Healthcare Room Pressure
products help provide safety in isolation rooms,
operating rooms, and other specialized spaces, by
continually measuring room pressure and indicating
room conditions. The PresSura products assist
hospitals and engineers to comply with relevant
ASHRAE, AIA, CDC and USP standards. TSI’s
unique thermal-based pressure sensor offers the
most precise, accurate, and stable measurement.
Over 50,000 hospital rooms in leading healthcare
facilities rely on TSI products every day to provide
effective 24/7 monitoring.
Safety & Compliance
Whether designing or managing healthcare
facilities, you understand that safety, compliance
and infection prevention are crucial considerations.
PresSura Room Pressure products provide the
confidence you need to comply with major industry
guidelines and regulations in order to ensure and
document safe environments. Specifically designed
for hospital applications, PresSura Room Pressure
Products offer:
• Best-in-class measurement of low pressures to
help monitor critical pressurized rooms
• Simplified compliance with relevant parts of the
following guidelines and regulations
• ANSI/ASHRAE/ASHE Standard 170-2008,
ventilation of health care facilities
• The Facility Guidelines Institute (FGI), 2010
Guidelines for Design and Construction of Health
Care Facilities
• Centers for Disease Control (CDC), Guidelines for
Environmental Infection Control in Health Care
Facilities
• Seamless integration into Building Automations
Systems (BAS) where data can be logged and
tracked over long periods of time
• Low maintenance and easy calibration
Through-the-Wall Sensor
General Features
Options
• Both monitor and control units available
• Includes room pressure, ventilation and
temperature controls
• Supports high accuracy through-the-wall pressure
sensor based on thermal anemometry
• Provides best-in-class accuracy, resolution and
stability
• Also supports pressure transducer input
• Suitable for Airborne Infection Isolation (AII) rooms
and Protective Environment (PE) rooms
• Positive / negative / no Isolation room modes
• Changeable via keyswitch and password
protected touchscreen
• Supports visual and audible alarms
• Programmable alarms delays to avoid nuisance
alarms and alarm mute feature.
• Standard communication options supported are
Modbus & BACnet MS/TP
• LonWorks available as an option
• Accepts flow, door switch, temperature and
relative humidity inputs
• Supports 0 – 10v / 4-20mA analogue output and
alarm relay contacts
• TSI Nurses Station Monitor can display status of
up to 8 rooms on 1 screen
Monitors – Single room
■■RPM10
• PresSura Standard Room Pressure Monitor with
Through-the-Wall Sensor
■■RPM10-PT
• PresSura Standard Room Pressure Monitor for
use with Pressure Transducer Sensor (not incl.)
Monitors – Multiple rooms (Up to 3)
■■RMP20
• PresSura Premium Room Pressure Monitor with
Through-the-Wall Sensor
■■RPM20-LON
• PresSura Premium Room Pressure Monitor with
LONworks Communications and Through-theWall Sensor
■■RPM20-PT
• PresSura Premium Room Pressure Monitor for
use with Pressure Transducer (not included)
■■RPM20-PT-LON
• PresSura Premium Room Pressure Monitor with
LONworks Communications for use with Pressure
Transducer (not included)
Nurses Station Monitor
Controllers
■■RPC30
• PresSura Premium Room Pressure Controller with
Through-The-Wall Sensor
■■RPC30-LON
• PresSura Premium Room Pressure Controller with
LONworks Communications and Through-theWall Sensor
■■RPC30-PT
• PresSura Premium Room Pressure Controller for
use with Pressure Transducer (not included)
■■RPC30-PT-LON
• PresSura Premium Room Pressure Controller
with LONworks Communications. For use with
Pressure Transducer (not included)
Pressure Transducers
■■TSI 801916 - PRESSURE TRANSDUCER
+- 0.1 IN H2O (+/- 24.9PA)
■■TSI 801917 - PRESSURE TRANSDUCER
+- 0.25 IN H2O (+/- 62.3 PA)
Nurses Station Monitor
■■NSD8 – NURSES STATION MONITOR
Other options available include keyswitches, door
switch and remote visual alarms.
22
KENELEC.COM.AU / 1300 73 22 33
HOSPITALS & LABS
FUME HOOD MONITORS
FMH10 FUME HOOD MONITOR
Fume hoods are a primary source or protection in
laboratories. Face velocity measurements are often
used to gauge the performance of a fume hood’s
ability to contain and exhaust hazardous chemicals.
By accurately measuring face velocity and alarming
on unsafe conditions, TSI’s FHM10 Fume Hood
Monitors provide a high level of fume hood safety.
The FHM10 helps users comply with standards and
regulations set forth by OSHA, NFPA, ANSI Z9.5,
and SEFA, calling for monitors to be installed on
fume hoods.
Check your hood flow and
filter efficiency using a
TSI 5725
General Features
Options
• Accurately measures average fume hood face
velocity
• Temperature compensated sensor for accurate
measurement as temperatures change in
laboratories
• Visual, audible and remote alarms warn users of
unsafe conditions
• Analog output provides additional information
• Assists in managing risk by communicating fume
hood status information to Building Management
System (BMS)
• Seamless integration via Modbus. BACnet and
LonWorks options available
• Easy installation and calibration
• Easy configuration using keypad
• Large display provides detailed fume hood
information
• Surface or flush mount options available
• Optional Flow Monitor available
■■FHM10-01
• Fume Hood Monitor with Velocity Sensor
■■FHM10-02
• Fume Hood Flow Monitor (using existing flow
station or venturi valve)
TSI 5725
General Features
NATA
CALIBRATION
IS AVAILABLE
KENELEC.COM.AU / 1300 73 22 33
• 0.25 to 30m/s air velocity range
• 0 to 60°C temperature range
• Volumetric air flows, sweep mode, 100mm head
• Air cone flow hood compatible
• 12,700 point data logging, software & USB
• Includes calibration certificate & 2 year warranty
• NATA calibration is available
23
HOSPITALS & LABS
FUME HOOD CONTROLLERS
FMC50 FUME HOOD CONTROLLER
TSI 800920 Slimline Module
Sash Position Sensor
FHC50 with Sidewall sensor (with FHC50-01)
The Model FHC50 Fume Hood Controller adds the ability to control airflow to
maintain safety and energy efficiency.
There are two main monitor and control strategies that can be used with the
Model FHC50 Fume Hood Controller:
Face Velocity
One of the key components of air flow in a fume hood is adequate face velocity,
which is needed to protect fume hood users. An adequate face velocity will help
contain contaminants inside of the fume hood.
A fume hood exhaust system produces a negative pressure differential between
the fume hood’s interior and the laboratory, causing air to be drawn into the
hood. The speed of air entering the fume hood is called the face velocity. The
Model FHC50 Fume Hood Controller can be configured to continuously monitor
fume hood face velocity by measuring the air velocity across a sensor mounted
in the sidewall of the hood. The sensor and opening in the fume hood are driven
by the same pressure differential so the velocity across each is related.
As an alternative to this sidewall sensing methodology, the Model FHC50 can
determine average fume hood face velocity by measuring the fume hood exhaust
flow and sash area. When measuring face velocity in this fashion, the Model
FHC50 must use a venturi valve with feedback to control and measure the
exhaust volume. A sash sensor then measures the vertical opening of the fume
hood sash. As an option, the Model FHC50 can use a sidewall sensor to monitor
or trim the face velocity when calculated from sash position and exhaust flow
rate.
The Model FHC50 controller modulates the exhaust to maintain an adequate
face velocity at all FHC.
Exhaust Flow
Certain devices such as laminar flow benches, canopy hoods and snorkels need
to exhaust a certain amount of air to function properly. For these applications,
the Model FHC50 can be configured to measure and control the air flow to a
constant volume using a venturi valve or a flow station with damper.
24
General Features
• Controls fume hood face velocity to provide containment and safety
• Reduces laboratory air flow usage, optimizing energy savings
• Assists in managing risk by communicating fume hood status information to
Building Management System (BMS)
• Visual, audible and remote alarms warn users of unsafe conditions
• Seamless integration via Modbus. BACnet and LonWorks options available
• Easy installation and wiring
• Fast-acting actuator provides containment during sash movements
• Easy configuration using keypad or configuration software
• Large display provides detailed fume hood information
• Surface or flush mount options available
Options:
■■FHC50-01
• Fume Hood Controller – Closed loop control of face velocity using thermal
anemometry (sidewall sensor)
■■FHC50-02
• Fume Hood Controller – Open loop control of face velocity using sash position
sensor
■■FCH50-03
• Fume Hood Controller – Combines open loop control using sash position sensor
and closed loop control using sidewall velocity sensor to optimize speed of
response
■■TSI 800920
• Slimline Interface Module for FHC50 and FHM10
KENELEC.COM.AU / 1300 73 22 33
HOSPITALS & LABS
VENTILATOR TEST SYSTEMS
TSI 4070 CERTIFIER FA VENTILATOR TEST SYSTEM
The Certifier® FA Ventilator Test System 4070 is
capable of testing multiple parameters of ventilator
performance. It is designed to measure air, oxygen,
and nitrous oxide flow and pressure in institutional,
home care, field service, laboratory, and production
applications. The Certifier FA ventilator test system
is a battery-operated flow analyzer that can also
test a variety of other medical equipment such
as anesthesia gas delivery machines and oxygen
concentrators.
Their compact size makes these ventilator testers
ideal for use in field service, biomedical shops, and
manufacturing.
General Features
• Gas calibrations for air, O2, air/O2 mixtures and
N2O
• Uni-directional flow
• Temperature and pressure compensated
• Max breath rate 120 BPM
• STP, ATP & BTBS flow & volume modes
• LCD Display
• Barometric pressure 500 to 2000 mbar
• Low pressure -25 to 150 cm H20 gauge
• Oxygen concentration (with optional 4073 Kit)
Options
■■TSI 4073 OXYGEN SENSOR KIT
■■TSI 4072 LOW-FLOW MODULE
TSI 4080 CERTIFIER FA PLUS VENTILATOR TEST SYSTEM
Certifier® FA Plus Ventilator Test System 4080 is the
full-feature system capable of testing virtually all
models of ventilators: adult, pediatric, anesthesia,
neonatal and high-frequency. It can also test
a variety of other medical equipment such as
anesthesia gas delivery machines, insufflators and
oxygen concentrators. Its compact size makes
this ventilator tester ideal for use in field service,
biomedical shops, and manufacturing.
General Features
• Gas Calibrations for Air, O2, Air/O2 mixtures, N2,
CO2 and N2O
• Bi-Directional Flow
• Temperature and pressure compensated
• Max Breath Rate 1500 BPM
• STP, ATP, BTPS, BTPD and user-defined flow &
volume modes
• Colour Graphic touch screen
• Barometric Pressure 500 to 1700 mbar
• Low pressure -25 to 150 cm H20 differential.
• High pressure -10 to 150 PSI
• Oxygen Concentration (with optional 4073 Kit)
• USB interface for PC and printing
Options
■■TSI 4073 OXYGEN SENSOR KIT
■■TSI 4082 LOW-FLOW MODULE
■■TSI 1303860 USB CABLE MINI A TO STD B
KENELEC.COM.AU / 1300 73 22 33
25
HOSPITALS & LABS
MASS FLOW METERS
The TSI Mass Flowmeters can be used for a multitude of gas flow measurement
applications. Whether measuring gas flows in a laboratory or manufacturing
setting, TSI general purpose mass flowmeters provide accurate results with
multiple data output options. The display versions come complete with
accessories making setup and operation fast and convenient.
The TSI mass flowmeters are specified as two percent of flow rate reading.
One TSI mass flow meter covers the same range as three percent (or more) of
full scale devices, with better accuracy at most points. Fast four millisecond
response ensures accuracy in fluctuating flows. This fast response time of the
TSI mass flowmeter is ideal for closed-loop control systems and integrated
volume measurements. Low pressure drop of the TSI mass flowmeter minimizes
flow circuit back pressure and its impact on the system.
TSI LOW FLOW - 4140 SERIES
General Features
• TSI 4140 Low Flow series (0.01 – 20 std L/Min)
• TSI 4040 High Flow series (0 – 200 & 0 – 300 std L/Min)
• 4 millisecond flow response
• High accuracy ±2% of reading
• High turndown ratio
• Low pressure drop
• Versions available with or without display
• Convenient 0 – 10V DC analog output of flow rate
• Versatile RS232 digital output of flow rate, volume, pressure, temperature
• Built-in temperature and pressure compensation
• NIST-traceable calibration certificate included at no additional cost
TSI HIGH FLOW - 4040 SERIES
Low Flow – 4140 Series
High Flow – 4040 Series
Model
4140
41403
4143
41433
4040
Gas Calibration
Air, O2, N2
Air, O2, N2, N2O
Air, O2, N2
Air, O2, N2, N2O
Air, O2, N2, Air/O2 Mixture
Inlet/Outlet Diameter
0.25” (6.4 mm)
Flow
Measurement
0.375” (9.53 mm)
4043
4045
22 mm ISO
tapered
0.50” (12.7 mm)
0.75” (19.1 mm)
0-200 Std L/min
0-300 Std L/min
Range
0.01-20 Std L/min
0-300 Std L/min
Accuracy — Air
and O2
±2% of reading or 0.005 Std L/min, whichever is greater
±2% of reading or 0.05 Std L/min, whichever is greater
Accuracy — N2
±3% of reading or 0.010 Std L/min, whichever is greater
±3% of reading or 0.1 Std L/min, whichever is greater
Accuracy — Air
and O2 mixture
N/A
±3% of reading or 0.1 Std L/min, whichever is greater
Accuracy —
N2O
N/A
Response
4 ms to 63% of full scale flow
4 ms to 63% of full scale flow
L/min, Std L/min, cm3/min, Std cm3/min
L/min, Std L/min
Overall Dimensions
5” x 2” x 1.25” (127 mm x 49 mm x 32 mm)
7.2” x 2.5” x 2.1” (182 x 63 x 53 mm)
Volume*
Range
0.01 – 99.9 liters
0.01 – 99.9 liters
Measurement
Accuracy
±2% of reading (see Operator’s Manual for additional details)
±2% of reading (see Operator’s Manual for additional
details)
Pressure
Range
50-199 kPa absolute
50-199 kPa absolute
Measurement
Accuracy
±1 kPa
±1 kPa
Response
<4 ms to 63% of final value for step charge
<4 ms to 63% of final value for step charge
Temperature
Range
0-50°C
0-50°C
Measurement
Accuracy
±1°C at flow greater than 1 Std L/min
±1°C at flow greater than 1 Std L/min
Response
<75 ms to 63% of final value for step change
<75 ms to 63% of final value for step change
Analog
0-10 VDC flow only, zero and span adjustable via RS232
0-10 VDC flow only, zero and span adjustable via
RS232
Digital
RS232
RS232
7.5 VDC ±1.5 V, 300 mA max
7.5 VDC ±1.5 V, 300 mA max
LCD Display Units
Outputs
DC Power Input
26
±3% of reading
or 0.010 Std L/
min, whichever
is greater
N/A
±3% of reading
or 0.010 Std L/
min, whichever
is greater
N/A
KENELEC.COM.AU / 1300 73 22 33
HOSPITALS & LABS
TSI LOW FLOW - 4120 SERIES - NO DISPLAY
TSI HIGH FLOW - 4020 SERIES - NO DISPLAY
Low Flow – 4120 Series
Model
4121 Series
Gas Calibration
High Flow – 4020 Series
4122 Series
4021 Series
4024 Series
4121
41212
41216
41221
41222
41226
40211
40212
40241
40242
40246
Air
02
N2
Air
O2
N2
Air
O2
Air
O2
N2
Inlet/Outlet Diameter
0.25” (6.4 mm)
Flow
Measurement
Range
0.01-20 Std L/min
0-300 Std L/min
Accuracy — Air
and O2
±2% of reading or 0.005 Std L/min, whichever is greater
±2% of reading or 0.05 Std L/min, whichever is greater
Accuracy — N2
±3% of reading or 0.010 Std L/min, whichever is greater
±3% of reading or 0.1 Std L/min, whichever is greater
Response
4 ms to 63% of full scale flow
4 ms to 63% of full scale flow
5” x 2” x 1.1” (127 mm x 49 mm x 29 mm)
7.2” x 2.5” x 1.5” (182 x 63 x 38 mm)
Pressure Measurement
N/A
N/A
Temperature
Measurement
Range
0-50°C
0-50°C
Accuracy
±1°C at flow greater than 1 Std L/min
±1°C at flow greater than 1 Std L/min
Response
<75 ms to 63% of final value for step change
<75 ms to 63% of final value for step change
Analog
0-4 VDC flow only, zero and span adjustable via RS232
0-4 VDC flow only, zero and span adjustable via RS232
Digital
RS232
RS232
DC Power Input (User Supplied)
5.0 VDC ±0.25 V, 300 mA max
5.0 VDC ±0.25 V, 300 mA max
Recommended Filtration
HEPA-grade
HEPA-grade
Overall Dimensions
Outputs
0.375” (9.53 mm)
22 mm ISO tapered
0.75” (19.1 mm)
PRIMARY CALIBRATORS
TSI offers two Primary Calibrator Models for
calibrating pumps and any other air sampling
instruments that draw an active air sample.
These small, portable, battery-operated units are
lightweight and easy to use. Volumetric flow rate
is displayed continuously, making real-time pump
adjustment, calibration and periodic flow checks
fast and easy. These Primary Calibrators are
temperature-compensated and pressure-corrected
to calculate volumetric flow rate at an accuracy
within 2% of reading.
TSI 4146 PRIMARY CALIBRATOR KIT
RANGE – 2.5 TO 300 LPM
TSI 4046 PRIMARY CALIBRATOR KIT
RANGE – 0.01 TO 20 LPM
General Features:
• Provides continuous real-time volumetric flow rate
readings, so pump adjustment and calibration is
fast and easy
• Battery powered, compact and lightweight
• Field portable—use the same primary calibrator
for adjustment, calibration and periodic checks
• Comes with a NIST traceable calibration certificate
• Kits come complete and are ready to use
• Model 4146 flow measurement range of 0.01 to
20 lpm
• Model 4140 flow measurement range 2.5 to 300 lpm
• Each Primary Calibrator Model Includes:
Flowmeter, soft carrying case, battery pack, (6) AA
Alkaline batteries, connectors, tubing, dampening
chamber module (4146 only), battery pack lugs,
2-year warranty, user guide and NIST certificate
of calibration
KENELEC.COM.AU / 1300 73 22 33
27
SOUND & VIBRATION
DIFFERENCE BETWEEN LMAX, LMIN AND PEAK
When measuring noise levels Lmax and Peak should not be confused. Lmax is
the RMS (root mean squared) maximum level of a noise source or environment
where peak is the maximum level of the raw noise source.
RMS values give a clearer understanding of a noise level, making calculations
and measurements easier for a noise source waveform which is changing
constantly in its magnitude.
Jet Taking Off
(25 mtrs away)
• Lmax is the highest RMS sound pressure level within the measuring period
• Lmin is the lowest RMS sound pressure level within the measuring period
• Peak is the crest of the sound pressure within the measuring period
(This is not a RMS level)
120
Gunshot
Sound Pressure
110
1 minute
Pneumatic Hammer
Noisy Disco
Peak
Chainsaw
RMS
100
Angle Grinder
97
15 minutes
30 minutes
Personal Stereo
(Max Volume)
94
1 hour
91
88
85
2 hours
4 hours
8 hours
75
Below this level
hearing damage is
negligable
Ride-on Mower
90
Time
Busy Road
Power Mower
Vacuum Cleaner
Sound Pressure Graph
Conversation
Washing Machine
Library
Leaves Rustling
Sound Studio
Threshold of
Normal Hearing
80
70
60
50
40
30
20
10
0
The above noise levels are approximate and should only be
taken as a guide
Noise Level in Decibels
SOUND LEVEL METERS
SL-805 SOUND LEVEL METER
The SL-805 Digital Sound Level Meter is designed to meet the measuring
requirement of noise abatement project, sound quality control, health, safety
engineering at workshops, schools, hospitals, hotels, shopping centres, theatres,
recording studios, offices, traffic, homes etc.
General Features
• Designed according to the IEC651 type 2 & ANSI S1.4 type 2 for sound meter
• Sound Pressure Level measuring function (SPL)
• 2 measuring ranges: Lo (low) : 35 - 100dB / Hi (high) : 65 - 130dB
• 2 equivalent weighted sound pressure levels A and C
• 2 dynamic characteristic modes : S (slow) and F ( fast)
• Recording of MAX measuring value
• Data-hold function
• Low power indication
28
KENELEC.COM.AU / 1300 73 22 33
SOUND & VIBRATION
NOISE AT WORK MEASUREMENT
CASTLE SONUS GA116B AND GA216B
POCKET SOUND METERS
The entry level of the Castle Pocket Range of
Sound Level Meters is the SONUS B (GA116B &
GA216B), a feature packed, pocket instrument
that is fully compliant with IEC 61672-1:2002. This
meter gives simultaneous sound pressure (Lp) and
peak (Cpeak) measurement for a multitude of tasks
including Fire Alarm Testing and initial spot-check
assessments to the Noise at Work Regulations
1989. It has a high-specification measurement
microphone and is cased in tough, crack resistant
ABS plastic.
Designed for Engineers, Industrial Safety Officers
and anyone with a need for competent sound
measurements. This meter can assist with
compliance to the Health and Safety at Work Act;
Noise at Work regulation 1989. The Castle GA116B
is a great general purpose sound level meter that
will fit in your pocket and be ready whenever you
need it.
General Features
• Applicable Standard - IEC 61672-1:2002
(Integrating, Sound Exposure and Sound Level
Meters)
• Sound Pressure (Lp) to 0.1 dB resolution
• ‘A’ and ‘C’ frequency weighting (toggle)
• ‘Slow’ and ‘Fast’ Time weighting (toggle)
• Simultaneous measurement of Lp, Lmax, and
Cpeak
• Lmax - maximum Lp hold (rms.)
• Cpeak - maximum peak level
• Elapsed time (running time hrs, min, sec)
• Overload and Under-range indication
• Battery condition (Life approx. 12 hours)
CASTLE SONUS GA257B PERSONAL NOISE
EXPOSURE METER (DOSEMETER)
CASTLE SONUS GA257L PERSONAL DATALOGGING NOISE EXPOSURE METER (DOSEMETER)
The Castle SONUS GA257B is a dedicated basic
dosemeter and a feature packed, pocket instrument
that is fully compliant with IEC 61252:1993. This
meter gives simultaneous sound exposure (LEpd)
and maximum peak (Zpeak) measurements, an
essential feature for assessments to the Noise at
Work Regulations 1989. It has a high-specification
measurement microphone and is cased in tough,
crack resistant ABS plastic. Designed to be
worn by an employee for a full- or part-shift, the
GA257B has an ‘unbreakable’ pocket clip and a
lockable keypad. The results are given in a simple,
clear format to give an immediate indication of an
employee’s daily exposure.
Powerful, yet small and lightweight, the Castle
GA257L noise dose meter combines the latest
technological advances with a realistic price tag.
With it’s clear and easy to read 8 character alpha
numeric display, soft-touch keypad, electronic
security lock and instant calibration facility, the
GA257L is sure to prove invaluable in a wide range
of occupational health applications.
Designed for Industrial Safety Officers and Safety
Managers for compliance with the Health and
Safety as Work Act; Noise at Work regulation 1989.
The Castle GA257B provides all the necessary
information you need for completing Noise at Work
risk assessments.
General Features
General Features
• Applicable Standard - IEC 61252-1:1993
(Personal Sound Exposure Meters)
• Integrated Sound Exposure Level (LEpd)
• Projected LEpd (8 hour sound exposure)
• DOSE% and Projected DOSE% (8 hours)
• ‘A’ frequency weighting
• Zpeak - maximum peak level
• Simultaneous measurement of LEpd, and Zpeak
• Elapsed time (running time hrs, min, sec)
• Pa2hr (LEpd expressed in Pascals)
• Overload indication
• Battery condition (Life approx. 12 hours)
All measured values can be saved to the internal
flash memory of the GA257L for subsequent output.
The results can be viewed on the instruments own
display or downloaded to a PC using the included
software.
• Applicable Standards - IEC61672-1-2002 (Sound
Level Meters) & IEC61252-1993 (Personal Sound
Exposure Meters)
• Measures Lep, Dose%, Dose per Hour and Pa2H
• Measures simultaneously LAeq and either LZeq
or LCeq
• User selectable Exchange rate and Criterion level
• C or Z weighted peak
• Save results to internal flash memory
• Download data to a PC via a USB connection
• Analysis software included with the meter
• Small and light weight, fits into small shirt or
jacket pocket
• Lockable keypad
• Constructed of tough crack resistance plastic
• Single battery operation of approximately 12
hours
• Supplied with a strong clip for attaching to a belt
or shirt pocket
Options
■■GA216B SONUS
• Digital Sound Pressure Level Meter Class 2
■■GA116B SONUS
• Digital Sound Pressure Level Meter Class 1
CASTLE SONUS NK004B SINGLE LOGGING DOSEMETER KIT
CASTLE SONUS NK004 5 LOGGING DOSEMETER KIT
Utilises the powerful Castle GA257L Data-logging Dosemeter.
Utilises the powerful Castle GA257L Data-logging Dosemeter.
General Features
General Features
Includes the following components:
Includes the following components:
• 1 x GA257L Data-logging Dosemeter
• 1 x GA601 Calibrator – Single level, Class 2
• 1 x PC007 dBdataPRO Noise Analysis Software & Cable
• 1 x KA010C2 Small Attache Kit Case Class 2 (Sonus)
• 5 x GA257L Data-logging Dosemeter
• 1 x GA601 Calibrator – Single level, Class 2
• 1 x PC007 dBdataPRO Noise Analysis Software & Cable
• 1 x KA007 Dosemeter Kit Case (Accommodates 5 Dosemeters)
KENELEC.COM.AU / 1300 73 22 33
29
SOUND & VIBRATION
ENVIRONMENTAL SOUND MEASUREMENT
CASTLE SONUS NK007B SONUS
LOW NOISE WEATHERPROOF
CASTLE GA116E SONUS DEDICATED ENVIRONMENTAL DATA-LOGGING SOUND METER CLASS 1
The environmental model of the Pocket Sonus Meter range is the class one
Sonus GA116E. This instrument boasts an impressive noise floor reading
allowing for the measurement and recording of low level ambient noise.
The instrument is a full data logging and integrating sound level meter with a
total linear measurement span of 108dB.
Never before has such a credible and high performing environmental sound level
meter been available at such affordable prices.
The meter measures 3 percentiles one of which is user selectable plus the
meter features dual measurement, so two versions of most parameters can be
measured simultaneously.
General Features
• Applicable Standards - IEC 61672-1 : 2002 Class 1 Group X
• Measures Lp, Leq, Lmax, LE, L10, L90, L(user)
• Measures parameters simultaneously including LAeq and either LZeq or LCeq
• Under range and Overload indicators
• A, C or Z frequency weighting selection
• A, C or Z Peak measurements
• ‘Slow’, ‘Fast’ and ‘Impulse’ time weighting selection
• Save results to internal flash memory
• Download data to a PC via a USB connection
• Noise Analysis Software included with the meter
• Small and light weight, fits into small shirt or jacket pocket and also supplied
with a strong pocket clip.
• Lockable Key pad through options
• Single battery operation of typically 12 hours
• Weatherproof kit option
Utilises the powerful Castle GA116E Environmental
Data-logging meter.
General Features
Includes the following components:
• 1 x GA116E Dedicated Environmental Data
Logging Sound Meter
• 1 x GA607 Dual Level Acoustic Calibrator
• 1 x GA690 Barometer
• 1 x KA020 Weatherproof Case for SONUS sound
meters
• 1 x ZL2094-03 3m weatherproof cable for KA020
and SONUS sound meters
• 1 x MW402 Weatherproof Microphone Housing
for SONUS range
• 1 x PC007 dBdataPro Noise Analysis Software
COMBINED SAFETY / ENVIRONMENTAL SOUND MEASUREMENT
CASTLE SONUS GA116L SOUND LEVEL & NOISE EXPOSURE METER & SONUS GA216L SOUND LEVEL METER
The flagship model of the Pocket Sonus Meter
range is the class one Sonus GA116L which is
a full data logging, integrating sound and noise
exposure meter (dose meter) which has been
designed for both Noise at Work assessments and
Environmental Sound monitoring.
Simply unplug the sound meter pre-amplifier and
plug in the dose meter cable which is available
as an optional accessory to convert to a fully
functional dose meter. Setup couldn’t be easier,
simply select Noise at Work or Environmental from
the available user modes to automatically have the
correct parameters selected then press the Record
key to start logging.
Available as a Class 1 instrument – GA116L and
Class 2 Instrument – GA216L
General Features
• Applicable Standards – GA116L IEC 61672-1 : 2002 & IEC 61252 : 1993
• Applicable Standards – GA216L IEC 61672-1
• Measures Lp, Leq, Lmax, LE, Pa2h, Lep’d, Dose, Dose Per Hour, L10, L90,
L(user)
• Measures parameters simultaneously including LAeq and either LZeq or LCeq
• Under range and Overload indicators
• Hearing Protection using the HML method
• User selectable Exchange rate, Threshold and Criterion level.
• User Modes: Noise at Work, Environmental or ALL
• A, C or Z frequency weighting selection
• A, C or Z Peak Measurements
• ‘Slow’, ‘Fast’ and ‘Impulse’ time weighting selection
• Save results to internal flash memory
• Download data to a PC via a USB connection
• Noise Analysis Software included with the meter
• Small and light weight, fits into small shirt or jacket pocket and also supplied
with a strong pocket clip.
• Lockable Key pad through options
• Single battery operation of typically 12 hours
Options
■■GA216L
• SONUS Safety/Environmental Data-logging Sound Meter Class 2
■■GA116L
• SONUS Safety/Environmental Data-logging Sound Meter Class 1
30
KENELEC.COM.AU / 1300 73 22 33
SOUND & VIBRATION
CASTLE NK001A CLASS 1 & NK001B CLASS 2 DATA LOGGING SAFETY / ENVIRONMENTAL SOUND KITS
The Sonus L model features parameters for
measuring a wide range of applications. The Safety
and Environmental Data Logging Sound System
is designed for Noise at Work and Environmental
measurements and features the Sonus Logging
meter.
Select Noise at Work measurements for logging
noise levels in the workplace, or switch the
removable microphone for the dosemeter cable
microphone (available separately) and measure
personal noise and dose levels.
Environmental parameters include L10 and L90
measurements and a third selectable percentile
level.
The kit is available in 2 options, with GA116L Class
1 meter or GA216L Class 2 meter
CASTLE GA6224 CLASS 1 SOUND LEVEL METER FOR NOISE AT WORK
MEASUREMENTS & ENVIRONMENTAL MONITORING
Options
■■NK001A
• Class 1 Data-Logging Safety/Environmental
Sound System
• Kit includes:
• Class 1 GA116L - Safety/Environmental Datalogging Sound Meter
• GA607 Calibrator, Dual Level, Class 1 (includes
GA690 Barometer)
• KA010 Small Attache Kit Case
• PC007 dBdataPRO Noise Analysis Software
and Cable
■■NK001B
• Class 2 Data-Logging Safety/Environmental
Sound System
• Kit includes:
• Class 2 GA216L Safety/Environmental Datalogging Sound Meter
• GA601 Calibrator - Single Level, Class 2
• KA010 Small Attaché Kit Case
• PC007 dBdataPRO Noise Analysis Software
& Cable
CASTLE GA6226 CLASS 2 SOUND LEVEL METER FOR NOISE AT WORK
MEASUREMENTS & ENVIRONMENTAL MONITORING
Measuring noise really does not have to be
complicated, even for the novice, and the
Castle 6224 (Class 1) Integrating sound level
meter is designed with this in mind. The meter
is ideally equipped for carrying out Noise at
Work Risk Assessments, as well as the majority
of environmental survey work. The range of
parameters measured, the wide measuring
capability of the meter and the ease of use, mean
that this equipment is suitable for anything from
aircraft noise to lawnmower design, and from
construction sites to laboratories.
General Features
• Conforms with IEC 61672-1:2002, Class 1, IEC
60651:1979 and IEC 60804:2000 Type 1
• Measures Lp, LMH, Leq, LAe, Lmax, Lmin, Lx (L5,
L10, L50, L90, L95), Peak.
• Six ranges: 20 – 80dB, 20 – 90dB, 20 – 100dB, 20
– 110dB, 30 – 120dB, 40 – 130dB
• Frequency weighting A, C, FLAT
• Time weighting FAST, SLOW, IMPULSE
• 5 user selectable percentile values (Ln)
• Wide linearity range of 90dB
• RS232 for data output to optional software
• Memory storage for 10,000 data-points
• Back-lit LCD display
Class 2 Sound Level Meter – similar to the
GA6224. The Castle 6226 provides the essential
measurements required by the Control of Noise at
Work Regulations 2006, including Leq (equivalent
continuous level) in ‘A’ and ‘C’ weightings, and
Cpeak. The meter can data-log any of these
parameters in up to 10,000 data-memories, making
it more than powerful enough for the task in hand.
Also ideally suited to environmental monitoring,
the Castle 6226 can measure 5 selectable
percentile values and sound exposure (LE). Most
environmental measurements require Leq and L90
plus possibly one or two other measurements.
These can all be measured simultaneously with the
Castle 6226 and data-logged into its 10,000 datapoint memory.
General Features
• Conforms with IEC 61672-1:2002, Class 2, IEC
60651:1979 and IEC 60804:2000 Type 2
• Measures Lp, LMH, Leq, LAe, Lmax, Lmin, Lx (L5,
L10, L50, L90, L95), Peak.
• Six ranges: 20 – 80dB, 20 – 90dB, 20 – 100dB, 20
– 110dB, 30 – 120dB, 40 – 130dB
• Frequency weighting A, C, FLAT
• Time weighting FAST, SLOW
• 5 user selectable percentile values (Ln)
• Wide Linearity range of 100dB
• RS232 for data output to optional software
• Memory storage for 10,000 data-points
• Back-lit LCD display
CASTLE NK002C CLASS 1 & NK002D CLASS 2 RISK ASSESSMENT / ENVIRONMENTAL KITS
The meter is ideally equipped for carrying out
Noise at Work Risk Assessments, as well as the
majority of environmental survey work. The range
of parameters measured, the wide measuring
capability of the meter and the ease of use, mean
that this equipment is suitable for anything from
aircraft noise to lawnmower design, and from
construction sites to laboratories.
The Castle GA6224 and GA6226 provide the
essential measurements required by the Control
of Noise at Work Regulations 2006, including Leq
(equivalent continuous level) in A and C weightings,
and Cpeak. The meter can data-log any of these
parameters in up to 10,000 data-memories, making
it more than powerful enough for the task in hand.
KENELEC.COM.AU / 1300 73 22 33
General Features
Kit Contains:
• GA6224 - Class 1 Industrial/ Environmental
Logging SLM or GA6226 - Class 2 Industrial/
Environmental Logging SLM
• GA601 or GA607 - Acoustic Calibrator
• PC0226-4 - Data Management Software and
Interface Cable for use with GA6224/GA6226
• Carry case
Options
■■NK002C
• Class 1 Risk Assessment / Environmental System
■■NK002D
• Class 2 Risk Assessment / Environmental System
31
SOUND & VIBRATION
NOISE RECORDING - NOISELOG
CASTLE NOISELOG – NOISE RECORDER SYSTEM
Recording neighbourhood nuisance noise has
always been a costly, time-consuming affair with
tape storage, calibration difficulties and analysis
problems afterwards.
The Castle NoiseLog solves all of these problems
providing a cost effective solution allowing noise
complainants to record offending noises for
measurement and identification, thus assisting with
fast and effective dispute resolution. Following a
simple set-up, the complainant is left with a single
button switch to start and stop recordings instantly.
The use of SD cards means recording time is only
limited by the size of the card.
Each NoiseLog kit is supplied with:
• GA507 Noise Log Sound Recording System
including mains power unit, handset, microphone,
preamplifier and cable with table-top tripod and
mounting adaptor
• GA607 Dual Level Calibrator (94dB/104dB)
• Noise Log PC Software
General Features
• Class 1 and Class 2 versions meet the same
frequency response and dynamic range
requirements as sound level meters complying
with IEC 60651 or IEC 61672
• Available in 3 versions – Class 1, Class 2 and
budget
• CD quality recording onto SD memory card
• Simple one-push handset to start and stop
recording
• Recording time only limited by size of SD card
memory fitted. Supplied with 1GB card giving
3.25 hours recording at 44.1 kHz sampling rate.
• All contained in one robust, lockable metal
case. All cable connections and controls except
handset not accessible once locked
Options
■■NK030A CLASS 1
■■NK030B CLASS 2
■■NK030C BUDGET
Noise Recorder Software
NOISE ACTIVATED WARNING SYSTEMS
CASTLE GA902 NOISE ACTIVATED WARNING SYSTEM
According to industrial safety law, areas subject to hazardous noise must be
clearly defined, and workers notifies of the danger. In many cases, the noise
hazard is intermittent and that’s precisely the situation for which the GA902 was
designed.
The GA902 activates only when the noise exceeds a pre-set level allowing
exposed workers to wear ear defenders - often a less than popular safety
measure - only when absolutely necessary.
General Features
• Measuring Range 74dB to 112.5dB
• Trigger level adjustable in 2.5dB steps
• Housed in a rugged enclosure – stainless steel housing also available for food
and pharmaceutical
• ‘A’ Frequency weighting in accordance with IEC651 Type 2
• Supports additional remote beacon and a mini-beacon that attaches to
underside of GA902
• Integrated microphone. Supports remote microphone option
• Mains powered with ‘On’ indicator
32
CASTLE GA904 ELECTRONIC ORANGE
(ENTERTAINMENT NOISE CONTROLLER)
Everybody likes to party, but it’s all too easy to let music levels get out of hand and when the morning comes, complaints come rolling in and your licence is on
the line. The Castle Electronic Orange Noise Controller will keep your premises
free from the risk of complaints and closure. The unit is connected to the main
power supply for the amplification equipment. The Electronic Orange flashes a
warning when pre-set sound levels are exceeded.
If the operator doesn’t turn down the sound within a pre-set time, an automatic
cut off kicks in. The music never has to stop, because a warning light flashes if
the limit is exceeded, and only when this is ignored does the power supply cut
off to prevent further abuse. Pioneered by Castle, this unit, approved by The
Environmental Health, is used by thousands of venues through the World, and
the latest model is as easy to use, robust and reliable as ever.
General Features
• Easy to Install
• Simple to Operate
• Anti-tamper Protection
• Trip range 75dB to 112.5dB in 2.5dB steps
• Trip time 1 sec to 10 sec, user adjustable.
• Modes - Manual: Tripped unit must be manually reset / Auto:Tripped unit
automatically resets after trip time.
• Frequency weighting - ‘A’ and ‘B’ in accordance with IEC651 Type 2
KENELEC.COM.AU / 1300 73 22 33
SOUND & VIBRATION
CASTLE GA907 DBALERT PERSONAL NOISE WARNING UNIT
dBAlert! is a personal noise monitor that activates only when the noise exceeds
a pre-set level, warning exposed workers that noise levels have become
dangerous and to put on their ear-defenders. Perhaps more importantly for the
employee, this means that they will also know when they can legally take them
off!
Being of rugged construction, dBAlert is suitable for most industrial situations.
It comes complete with a pocket clip and the membrane keypad means that
integrity and simplicity of use are maintained.
dBAlert! also includes a vibrating alert , which gives the wearer the added
warning of a mobile phone style vibrating alert to bring attention to the fact that
dangerous noise levels have been exceeded.
General Features
• Measuring range 80dB to 103dB
• User-Selectable to 80dBA, 85dBA, 90dBA and 95dBA (factory set to 80dBA)
• Frequency weighting - ‘A’ in accordance with IEC 61672-1:2002 Class 2
• WARNING LED 1 x Hyper-Bright, LED,pulsed through software control
• VIBRATING ALERT Mobile phone style vibrating motor for tactile warning
(approx 150Hz)
• Weight 70g (with batteries)
Options
■■QUANTITY 1 OFF
■■QUANTITY 5 OFF
■■QUANTITY 10 OFF
KENELEC.COM.AU / 1300 73 22 33
GA908 SOUND CHECK PERSONAL NOISE INDICATOR
Excessive noise in the workplace is common in many professions and is a
potential risk for a large number of employees. It can lead to hearing loss which
is a permanent work-related injury.
It is not only in the workplace that noise can be a problem, music events, discos
or other leisure activities where excessive noise is involved can be one of the
greatest causes of hearing damage- especially for young people who are not
aware of the dangers!
The Sound Check allows you to assess at a glance, situations that may affect
your hearing in and out of the work place. It contains a microphone sensor that
registers noise levels in the wearer’s surroundings. A microchip translates this
into light - in coloured LEDs as follows:
GREEN = < 80 dB(A)
YELLOW = 80-100 dB(A)
RED = > 100 dB(A)
General Features
• Weight = 22g
• Dimensions = 85mm x 55mm x 8mm
• Accuracy = +/- 5dB
• Battery life = max 100 hours.
• Trip levels = Green < 80dB, Amber < 100dB and Red > 100dB.
Options
■■QUANTITY 1 OFF
■■QUANTITY 5 OFF
■■QUANTITY 10 OFF
33
SOUND & VIBRATION
VIBRATION INSTRUMENTS - CONDITION MONITORING
CASTLE GA2006S CASTLE VEXO S SINGLE AXIS
MACHINERY VIBRATION METER
CASTLE GA2002 POCKET VIBRATION METER
Simple to use Vibration Meter for measuring acceleration, velocity and
displacement. Ideal for checking fixed monitoring systems, condition
maintenance prediction and other engineering operations.
Reliable, repeatable and simple are three important criteria most people have
when looking at taking vibration measurements. The GA2002 offers this on a
plate and at a price unbeatable for what you get. This Instrument will give you all
the fundamental vibration measurements in many of their variations using single
key strokes. This makes it perfect for general machine and bearing vibration
monitoring as well as other general-purpose vibration measurements.
When you purchase a GA2002 it comes as a complete working system.
The following components are included:
• GA2002 General Purpose Pocket Vibration Meter
• KD1001 Basic Accelerometer
• ZL1094-M12 Accelerometer Cable
• KD1204 Magnetic Mount
• KD1206 Small Spike Probe
• KA013 Kit Case
The Vexo S is dedicated to monitoring vibration from industrial sources such
as rotating machinery, bearing housings and any other source of mechanical
vibration. With dedicated alarm modes for machinery rating and bearing condition,
the Vexo S is perfect ly suited to busy maintenance teams who need the right
answers right now!
The supplied re-chargeable battery pack and charger means you also won’t ever
be fumbling around for fresh batteries when you are supposed to be on the shop
floor making measurements!
The GA2006S is supplied with the following components:
• Vexo S Instrument, Accelerometer and 1m Cable
• Rechargeable battery pack and recharger
• Removable Spike Probe
• Getting Started Laminated Sheet
• Vibdata LITE software & USB Cable
• Carry Case for GA2006S and Accessories
General Features
General Features
• Small and light weight
• Simple to Use
• Highly Robust
• Tactile Keypad
• 8 Character LCD Display
• Simple Data-logging of 9 Data-points
• Comes complete with Accelerometer, Cable, Spike Probe and Case
• Multiple Filters - Mechanical and Linear
• Multiple Integration Modes - Acceleration, Velocity and Displacement
• Multiple Measurements - RMS, Max RMS and Peak
• Machinery condition monitoring to ISO 10816-1, 3 & 7
• Bearing condition indication
• Trending analysis (with optional VibdataPro)
• Environmental Vibration
• Single Axis mode for simple setup
• Large colour display
• Large ‘Flash’ memory
• Re-chargeable battery pack and charger
• Only 3 operational buttons for simple use
• Built tough with rugged accelerometer and cable
CASTLE VK027 PRO-DX EXCIEO GENERAL PURPOSE VIBRATION SYSTEM
This general purpose Excieo vibration meter
system includes a rugged accelerometer and cable
along with a spike probe, PC software and an
attaché case. The GA2005 Vibration Meter boasts
multiple frequency filters covering a wide range of
applications. It has large data-logging capabilities
with the option of recording time-histories, useful
in Environmental measurements. This rugged
instrument is also incredibly simple to use with good
battery life and fast download to a PC via USB
The following components are included in the
VK027 Pro-DX Excieo General Purpose Vibration
System:
General Features
• Advanced data-logging functions and simple file
management
• 1 second to 12 hours log time intervals
• 12 Frequency Filters
• KD1003 - Sensitivity: 100mV/g, Range (f.s.) ±80g
• KD1003 - Frequency response 2-13000Hz +5%
• Display Electro-Luminescent, Back-lit LCD panel
(160x160 pixels)
• Suitable for environmental monitoring, machine
condition and bearing condition monitoring
• GA2005S - Pro-DX Excieo Multi-purpose
Vibration Meter (not HARM or WBV)
• KD1003 - Standard Accelerometer (Amplified
Output)
• ZL1097-FLEX - Flexible coil cable for general
purpose measurement
• KD1205 - Large Spike Probe
• KA016V - Kit case for Excieo
• PC009 - VIBdataPRO
34
KENELEC.COM.AU / 1300 73 22 33
SOUND & VIBRATION
VIBRATION INSTRUMENTS – HUMAN VIBRATION MEASUREMENT
CASTLE GA2003 POCKET HARM (HAND ARM RISK MEASUREMENT)
VIBRATION METER
Damage to the Hand and Arm through exposure to vibrating hand held power
tools is rapidly becoming a major area of health and safety risk assessment.
Up to now, the process of gathering data to support such a program has been
both difficult and costly. The GA2003 will provide the data you need to calculate
daily exposure as recommended in the HSE guide HS(G)88, for an individual
employee. This is exactly what has been missing from the equation where Hand
Arm Vibration is concerned.
The GA2003 is suitable for industrial vibration measurements, machine condition,
building vibration and Hand Arm vibration indicative measurements.
The following components are included with the GA2003:
CASTLE GA2006H CASTLE VEXO HARM (HAND ARM RISK MEASUREMENT)
VIBRATION METER & VK036 VEXO HARM VIBRATION SYSTEM
Quick, reliable measurements are all-essential when it comes to the assessment
of Hand Arm Vibration and the Vexo H has been specifically designed to
make the job as simple as possible. The small size, combined with a powerful
processor and large memory will enable Safety Professionals to take Hand Arm
Vibration to the next level.
VK036 kit includes the GA2006H plus VIBdataPro Vibration Analysis Software.
VIBdataPro gives you quick access to all your data and allows you to analyse
data and export for reporting.
The following components are included with the GA2006H:
• GA2003 HARM®/Gen. Purpose Pocket Vibration Meter.
• KD1001 Basic Accelerometer
• ZL1094-M12 Accelerometer cable
• KD1207 General Purpose Mounting Block
• KA013 Kit Case
• Vexo H Instrument, Accelerometer with 1.4m Cable
• Accelerometer Mounting Block and Screw
• Rechargeable Battery Pack and Recharger
• Getting Started Laminated Sheet
• Vibdata LITE software & USB Cable
• Carry Case for GA2006H and Accessories
General Features
The following components are included with the VK036:
• Small and Light weight
• Simple to Use
• Highly Robust
• Tactile Keypad
• 8 Character LCD Display
• Simple Data-logging of 9 Data-points
• Comes complete with Accelerometer, Cable and HARM BLOK®
• Multiple Filters (Mechanical and HARM®)
• Multiple Parameters (Acceleration, Velocity and HARM®)
• Multiple Measurements (Lav, rms, Max.rms. and Peak & Elapsed Time)
• GA2006H components as listed above.
• PC009 VIBdataPro Vibration Analysis Software
General Features
• For compliance with:
ISO 5349 : 2001 Measurement and evaluation of human exposure to handtransmitted vibration
• Parameters Acceleration - Arms, Aeq, Amax, Peak, Vector Sum, Exposure
Points
• Full Colour Graphic OLED Display (160 x 128)
• Frequency Weighing WH - Hand Arm Filter
• Transducer Castle KD1010 Tri-Axial Accelerometer, 10 mV/g
• Flash memory storing up to 992 recordings
Options
■■CASTLE VEXO HARM VIBRATION METER ■■CASTLE VEXO HARM VIBRATION SYSTEM
CASTLE EVEC SELF-CONTAINED WHOLE BODY VIBRATION METER
Evec was designed to facilitate the measurement
and evaluation of whole-body vibration. Evec offers
advanced technology which can be learned easily
and quickly, even by untrained users.
The seat sensor, including its integrated memory, is
just placed on the driver’s seat - without having to
be mounted mechanically and without needing any
disturbing cables. The sensor is activated and the
measurement thus started with just a few operator
steps. The necessary software is installed on a
PDA or a notebook with Bluetooth interface. You
need just a few settings – and your evec system is
ready for use. The data recorded is also read from
the seat sensor through Bluetooth. There are no
annoying cables which might be damaged during
the measurement. The driver does not have to do
anything. The evec system automatically registers
when the driver gets up and, complying with EN
14253, cuts off the peaks when the driver sits down
too energetically.
This allows precise measurements of the load to
which the driver is exposed through the effect
of vibrations. Special data preparation is not
necessary. Conforming to EU Directive 2002/44/
EC, the evec software calculates the A(8) value
of the daily exposure, no matter whether the
measurement covered the full span of eight hours
or whether evaluation is based on a shorter time
period.
KENELEC.COM.AU / 1300 73 22 33
The following components are included with the
EVEC whole-body vibration system:
• Evec seat pad with integrated sensor
• CD-ROM with software for PDA and notebook
• Evec battery charger incl. batteries
• Plastic case with magnetic on-off switch
• Operating instructions in English
• Optional: PDA or notebook with preinstalled
software
General Features
• Meets standards ISO 2631, ISO 10326, ISO 8041,
VDI 2057, EN 14253, ISO 10326
• Storage Capacity for a measurement of 36 hours
• Wireless communication between sensor and
PDA or Notebook
• Evec seat pad according to ISO 10326 (in black)
with integrated triaxial acceleration sensor
• Microcontroller for evaluating acceleration signals
according to ISO 2631
• Algorithm for identifying and eliminating undesired
effects
• Driver-seat contact sensor
• Easy-to-operate
• Short training period
• Automatic identification and elimination of
undesired effects
• Automatic calculation of exposure time (ET) and
daily exposure A(8)
35
OTHER PRODUCTS AND CATALOGUES
ENVIRONMENTAL MONITORING
CLEAN ROOM MONITORING
Real Time Dust Monitoring Systems, Gravimetric
Sampling, Dust Deposition Gauges, High Volume
Samplers, Diesel Particulate Monitoring, Emission
Testing, Microbial Air Sampling, Weather Stations,
Rain Gauges, Tip Buckets, Wind Speed &
Direction.
Particle counters, EMS Systems, Microbial
Samplers, Education, Training, Validation,
Lab Testing, Ventilation Test Instruments
& General Instruments
Portable & Fixed Air Quality Monitors, Dust
Monitors, Ventilation Testers, CO2, CO and
Multi-Gas Monitors, Sample Pumps, Clean Room
Monitors, Computer Room Testers, Microbial
Samplers
SOUND & VIBRATION PRODUCTS
State-of-the-art, Latest Generation Systems
and Instruments. Portable Sound Meters,
Tripod Based Stations, Portable Vibration Meters,
Fixed Sound & Vibration Products & Accessories
WATER QUALITY MONITORING
Water Particle Counters, Streaming Current
Monitors, Water Quality Meters, Water Level
Meters, Water Flow Meters, ORP, DO,
Conductivity, pH, Turbidity, Salinity,
Temperature, Ozone, Chlorine
VENTILATION TEST EQUIPMENT
Hotwire & Vane Anemometers, Air Balancing
Hoods, Manometers, Indoor Air Quality
Meters, Gas Leak Detectors, Data Loggers,
Temperature & Humidity Meters
WEATHER STATIONS
Low Cost Wireless Weather Stations, Middle
Range General Purpose Stations, High
Performance Top End Stations, Rain Gauges,
Weather Sensors, Data Loggers, Dust Monitors
Nd:YAG Lasers, PIV Lasers, Laser Ablation
Systems, Micro Machining Systems,
Continuous Wave Lasers, Wafer Scribing
Systems, Sample Cells & General Accessories
SPEED & LENGTH MEASUREMENT
The Latest Technology in Laser Speed &
Length Measuring Systems for Metal &
Industrial Applications. Non-Contact Speed
and Length Measurement Gauges & General
Accessories
FILTER TESTING EQUIPMENT
Portable Hand-Held Particle Counters, Air
Velocity Meters, Manometers & Pressure
Meters, Dedicated High End Filter & Respirator
Testers & General Testing Instruments
PARTICLE & AEROSOL RESEARCH
Particle Counters & Sizers, Atomizers &
Aerosol Generators, Water & Butanol Based
CPCs, Aerosol Research Instruments, Aerosol
Accessories, Ultra-fine & Nano Particle Instruments
FLUID MECHANICS
LDV Systems, PDPA Systems, PIV Systems,
Global Spray & Imaging Systems, Hotwire
Anemometer Systems, PIV Lasers, Mounts,
Cameras, Probes & Accessories
DATA LOGGERS & TELEMETRY
Portable Low Cost Data Loggers, Middle & High
End Loggers, Solar Panels, Telemetry Systems,
SCADA System Integration, RF Transceivers,
Satellite Telemetry, Batteries, Outdoor Enclosures
VISA, MASTERCARD, AMEX Accepted
Please note: the prices in this catalogue are provided as a guide only and are subject to change without notice.
Please check at time of purchase. Delivery cost and GST are not included. (4% +GST surcharge on AMEX)
Australia & NZ Head Office
NSW Office
1300 73 22 33
23 Redland Drive
Mitcham VIC 3132 Australia
Building 5, 49 Frenchs Forest Rd
Frenchs Forest NSW 2086 Australia
Email - info@kenelec.com.au
T +61 3 9873 1022 / F +61 3 9873 0200
T +61 2 8977 4017 / F +61 2 8977 4000
National Freecall No.
www.kenelec.com.au
765 / OH&SCAT-NP / 14867 / APR15
INDOOR AIR QUALITY