OHS Catalogue v 27 - Kenelec Scientific
Transcription
OHS Catalogue v 27 - Kenelec Scientific
OH&S CATALOGUE TECHNICAL CATALOGUE 27 kenelec.com.au 1300 73 22 33 WELCOME TO KENELEC SCIENTIFIC Established in 1962, Kenelec Scientific is one of Australia’s leading scientific & environmental technology companies. With offices in Sydney and Melbourne and key distributors located throughout Australia and New Zealand, we are recognised as well connected, innovative industry leaders in the supply of globally sourced, latest generation technologies, at competitive prices. We provide an extensive range of scientific and environmental solutions, employing highly trained and experienced sales and technical staff. We also maintain state-of-the-art NATA accredited calibration laboratories offering a range of popular laboratory services. In house professional services to assist in design, installation and ongoing maintenance are also available. We operate a Quality Management System that fully complies to ISO 9001:2008 and is committed to providing the highest level of service and technical support on a wide range of quality products. We strive to understand your needs and offer solutions, off the shelf or adapted in house, to suit the project. The strong relationships forged with our customers, suppliers and other stakeholders over the many years are testament to the dedication of our staff, many of whom have over 20 years experience with us. Kenelec Scientific is 100% Australian owned, with a reputation for integrity and reliability forged over 50 years. Please enjoy this new edition. For further information or product advice our contact details are below. We look forward to working with you. Validation services to industry are offered and repairs and service is carried out at our Melbourne facility by factory trained technicians. Many products are stocked for sale or are available for short and long term rental. sales@kenelec.com.au www.kenelec.com.au Kenelec Scientific Pty Ltd Australia & NZ Head Office Kenelec Scientific Pty Ltd NSW Office 23 Redland Drive Mitcham VIC 3132 Australia Building 5, 49 Frenchs Forest Rd Frenchs Forest NSW 2086 Australia T +61 3 9873 1022 F +61 3 9873 0200 T +61 2 8977 4017 F +61 2 8977 4000 OCCUPATIONAL HEALTH & SAFETY RESPIRATOR FIT TESTING 4 Mask Fit Testing - Why Fit Test?...................................................... 4 IAQ & GAS MONITORING 18 Indoor Air Quality........................................................................... 18 Portable Gas Monitors................................................................... 19 AIR SAMPLING 6 Introduction to Aerosol Particle Sizes and Health Hazards............. 6 Real Time - Aerosol Monitoring....................................................... 7 Gas Detection Controllers.............................................................. 20 HOSPITALS & LABS 22 Real-time DPM Monitoring............................................................... 7 PresSura Room Pressure Products............................................... 22 Gravimetric Analysis - Air Sampling Pumps.................................... 8 Fume Hood Monitors..................................................................... 23 Accessories for Sample Pumps....................................................... 9 Fume Hood Controllers.................................................................. 24 Preassembled Air Sampling Filter Cassettes................................. 10 Ventilator Test Systems.................................................................. 25 Unassembled Air Sampling Filter Cassettes.................................. 11 Mass Flow Meters.......................................................................... 26 DustTrak - Aerosol Mass Concentration Measurement................. 12 Primary Calibrators........................................................................ 27 Particle Counting............................................................................ 13 Nanoparticle Surface Area Monitor................................................ 13 SOUND & VIBRATION 28 ASBESTOS14 Difference between Lmax, Lmin and Peak.................................... 28 Abatement Sampling Pumps......................................................... 14 Noise at Work Measurement.......................................................... 29 Asbestos Sampling Cassettes & Accessories............................... 15 Environmental Sound Measurement.............................................. 30 Sound Level Meters....................................................................... 28 Combined Safety / Environmental Sound Measurement............... 30 MICROBIAL SAMPLING 16 Noise Recording - NoiseLog.......................................................... 32 Bio Pump Sampling....................................................................... 16 Vibration Instruments - Condition Monitoring................................ 34 Other Sampling Technologies........................................................ 17 Vibration Instruments – Human Vibration Measurement............... 35 Noise Activated Warning Systems................................................. 32 Please note: the prices in this catalogue are provided as a guide only at April 2015 and are subject to change without notice. Delivery cost and GST are not included. Errors and omissions excluded. RESPIRATOR FIT TESTING MASK FIT TESTING - WHY FIT TEST? Under Australian and NZ Standards, everyone using a mask in any workplace must be fit tested before starting, and at least annually thereafter. Without an enforced, documented fit testing program, your organisation could be found legally liable as an unsafe workplace. Verification of Training A Fit Test checks that the worker has learned how to properly put on and wear a respirator without assistance. Sizing Fully complies with: AS/NZS 1715: 2009 OHSA (USA) HSE (UK) It is important to make sure that a respirator is the right size and therefore capable of providing protection when worn properly. Quantitative fit testing is accurate, fast and safe for your workers. PORTACOUNT results are immediate and unambiguous. Take a step up from the old-fashioned guesswork of qualitative fit testing and provide an objective measurement of the quality of the seal between the wearer’s face and the facepiece; producing a Fit Factor for each staff member in real time Fit Factor A Fit Factor is a measure of how well a particular face piece seals against a person’s face. It is a number that is the direct result of a measurement made during a simulation of workplace activities (the exercises). It is a ratio of the number of particles inside and outside of the mask. The PortaCount can measure fit factors from 1 to over 10 000. Due to the precision of its patented particle counter, the PortaCount is considered by far the world’s most accurate Fit Tester. FF= Particle Count Outside Respirator Particle Count Inside Facepiece How it works The PortaCount® respirator fit testing equipment measures real-time fit while the user performs a series of moving, breathing and talking exercises designed to simulate the same movements made in the workplace. The step by step process is guided via the FitPro+™ Fit Test Software and stored in a database for easy report generation, retrieval and regulatory compliance. The stored data is easily transferrable via a USB drive. PortaCount can be operated by itself or it can also be connected to your own external computer to generate reports and print fit test cards. No other fit tester can quantitatively fit test so many types of respirators—gas masks, SCBAs, respirators, even disposables (with the 8038 model). Adaptor Kits Mask adapters kits allow a worker to be fit tested in their own mask. Available for an extensive range of respirators throughout Australia, you can order many models from Kenelec or your respirator manufacturer. To PortaCount Pro Class-100 Filter Cartridge Adapter’s Inhalation Valve Sampling Adapter Sample Inlet Sample Tube Cap Suction Cup Use the Real-time Fit Factor Display to show workers the real-time effects of mask positioning and strap tightness as they experiment and learn proper donning procedures. Software FitPro software provides the vital documentation you need for your respirator program. You can provide management with hard-copy evidence that each employee passed a fit test, was trained to don the respirator properly and assigned a mask size that fits correctly. Each PortaCount comes with the software and also access to free online training modules, webinars and free lifetime updates. If you have multiple PortaCounts the FitPro software enables you to fit test up to 4 people simultaneously - saving time and money. 4 Fit factors for anyone who has smoked recently will be lower than that individual deserves and may even cause them to fail the fit test entirely. Smokers exhale particles for at least 30 minutes after they have been smoking. The PortaCount Pro fit tester can count these particles and will interpret them as if they were caused by face seal leakage. Avoid retests by instructing smokers not to smoke for at least 30 minutes prior to fit testing. KENELEC.COM.AU / 1300 73 22 33 RESPIRATOR FIT TESTING TSI 8030 PORTACOUNT PRO RESPIRATOR FIT TESTER TSI 8038 PORTACOUNT PRO+ RESPIRATOR FIT TESTER RENT ME The starter model in the series will fit test all respirators except P1, P2 and N95 disposables. The 8038 model will fit test all respirators including P1, P2 and N95 disposable masks. Everybody, including site visitors, can be tested at a moments notice. General Features General Features • OSHA-compliant for all gas masks, SCBAs, respirators, respirators (full & half faced) but NOT P1, P2 N95 disposables. • Measures fit factors from 1 to greater than 10,000 • Automates fit testing with FitPro Fit Test software • Optional mask sampling adapters allow employees to be tested in their own respirators • Software prints fit test cards with fit test report or on ID cards • OSHA-compliant for all gas masks, SCBAs, respirators (full & half faced) INCLUDING P1, P2 N95 disposables. • Measures fit factors from 1 to greater than 10,000 • Includes 8026 Particle Generator to make Fit Testing easier in cleanrooms or airconditioned offices • Automates fit testing with FitPro Fit Test software • Optional mask sampling adapters allow employees to be tested in their own respirators • Software prints fit test cards with fit test report or on ID cards Options ■■FIT TEST CARD PRINTER ■■ADAPTOR KITS CALL FOR MORE INFO MASK INTEGRITY TEST ACCESSORY You’ve just cleaned your mask? Do you bet your life that you’ve reassembled it correctly? Designed by the leaders in quantitative fit testing technology, the TSI Mask Integrity Test Accessory (MITA) 8120 works in tandem with a PortaCount Respirator Fit Tester or CBRN Mask Protection Assessment Test System to quickly detect leaks in CBRN gas masks and commercial respirators and ensure your personnel are getting maximum protection. While under conditions of negative pressure and constant flow, the mask is tested on a full head form with an enhanced bladder seal system to provide a tight seal for most gas mask and full face respirator types and sizes. Testing the mask on this full head form configuration allows for use of the mask’s head harness, mimicking a real-life application and providing better representative results. Unlike anything else on the market*, when a leak is detected during the assessment, the integrated aerosol wand and generator is used to pinpoint invisible leaks for quick evaluation and repair. Additionally, MITA is capable of testing the integrity of a mask’s exhalation valve and drink tube when applicable. KENELEC.COM.AU / 1300 73 22 33 Some competitor models are not mask integrity testers. Their main function is to test SCBA regulators, air bottles and for some, test the step-down/breathing flow. Some units also use +/- pressure to check for large leaks, but since they do not generate particles, they do not have the sensitivity to determine where the mask is leaking from. General Features • Separate tests for overall mask integrity (Protection Factor), exhalation valve and drink tube • Integrated aerosol wand pinpoints leak locations, allowing for immediate evaluation and repair, potentially avoiding replacement costs • Efficient test sequence allows allows testing of up to 20 masks per hour *at March 2015 5 AIR SAMPLING INTRODUCTION TO AEROSOL PARTICLE SIZES AND HEALTH HAZARDS Particle Size-Selective Dust Sampling Particle Size Inhalable Thoracic (Total dust) Respirable Welding Fume Combustion Nuclei Wind blown dust Types of Particles Diesel Engine Exhaust Fly Ash Particle-size selective TLVs consider two points: Volcanic emissions Paint Pigment Oil Smoke 1 The size-fraction most closely associated with the specific health effect Pollen Sea salt Construction Activities Soot Bacteria Virus 0.01 The ACGIH recommends that particle-size selective TLVs be expressed in three forms: Coal Dust (mining) Tobacco smoke 0.001 2 The mass concentration within that size fraction which should represent the TLV Vacuuming Carbon Black 0.1 1 [micron (μm)] Particle Size Range (micrometers ) The hazard potential of airborne dust, solid particles, or droplets is dependent on the mass concentration as well as the particle size. Particle size determines the deposition site within the respiratory tract and the subsequent health effect. Therefore, the American Conference of Governmental Industrial Hygienists (ACGIH®) has recommended that particle-size selective Threshold Limit Values (TLV®s) be developed for inhalation hazards in the workplace. 4 10 100 Environmental / Naturally Occurring Particles Workplace / man-made Particles • Inhalable Particulate Mass Airborne particles having a 50% cut-point of 100µm. These dust particles are hazardous no matter where they are deposited in the respiratory tract • Thoracic Particulate Mass Airborne particles having a 50% cut-point of 10µm. These dust particles are hazardous when deposited anywhere in the lung airways and gasexchange regions • Respirable Particulate Mass Airborne particles having a 50% cut-point of 4µm. These dust particles are hazardous when deposited in the nonciliated gas-exchange regions of the lung RESPIRATORY DEPOSITION Blood Vessel Posterior Nasal Passage Extrathoracic Region Pharynx % Regional Deposition 1.0 0.8 0.6 Nasal, Pharyngeal, Laryngeal 0.4 0.2 0 0.001 Larynx 0.01 0.1 1 10 Diameter (μm) Tranchea Trancheobronchial Region Alveoli Bronchiole Alveoli % Regional Deposition 1.0 Bronchus Alveolar Region 0.8 Trancheobronchial 0.6 0.4 0.2 0 0.001 0.01 0.1 1 10 Diameter (μm) Unlike larger particles, ultra-fine particles are more easily inhaled and can penetrate deep into the lungs, potentially causing serious health effects. Below .05μm (micron) these particles can be absorbed directly into the blood stream, which again can cause a wide range of serious health problems. 6 % Regional Deposition 1.0 Reference: ICRP 1994 0.8 Alveolar 0.6 0.4 0.2 0 0.001 0.01 0.1 1 10 Diameter (μm) KENELEC.COM.AU / 1300 73 22 33 AIR SAMPLING REAL TIME - AEROSOL MONITORING TSI AM510 SIDEPAK PERSONAL AEROSOL MONITOR RENT ME With sampling pumps, you simply don’t get that dynamic real-time data that you can get with a TSI real-time AM510 monitor. The SIDEPAK AM510 series of personal aerosol monitors are rugged, lightweight, belt-mounted laser photometers. The built-in sampling pump lets you attach a wide variety of size-selective inlet conditioners for worker breathing zone or area measurements with a respirable cyclone or one of the three integrated impactors. The easy-to-read display shows your data in both real-time aerosol mass concentration and 8-hour time-weighted average (TWA), with datalogging enabling you to download stats to produce graphs and reports. General Features • 0.1μm to 10μm particle size range • 1 ug/m3 to 20 mg/m3 concentration range • 33,000 point data logging with software • Ideal for indoor air, environmental & OH&S work • Built-in pump, battery operated, ready to use Options ■■AA BATTERY MODEL ■■1650mAh BATTERY MODEL ■■2700mAh BATTERY MODEL REAL-TIME DPM MONITORING RENT ME Elemental Carbon (μg/m3) FLIR AIRTEC REAL-TIME DPM ELEMENTAL CARBON MONITOR 800 600 400 200 0 09:00 12:00 15:00 Time (hrs) 8-hour TWA EC Concentration Comparison via: 1: NIOSH 5040 150.25 μg/m3 2: Airtec monitor 154.36 μg/m3 The Airtec monitor is a compact and highly portable real-time elemental carbon monitor designed to determine exposure of workers in underground mines to DPM. Airtec uses a real time particle capture and light transmission method to yield elemental carbon values which closely correlate with NIOSH 5040 test results to measure EC and TC levels in underground mines. This monitor is designed to allow the operator and management to take immediate, remedial action to address a problem area. Levels can also be tracked over time to determine the possibility of long term health hazards and help eliminate the risks associated with over-exposure. During monitoring the Airtec uses consumables, generally a cassette will last a 12 hour shift with a change of pre-filter cartridge for every three cassettes used. The Airtec Starter Pack includes one consumable kit to start you off and you can order more depending on your requirements. KENELEC.COM.AU / 1300 73 22 33 General Features Options • Displays elemental carbon levels in true real-time • Laboratory accuracy in a small portable clip on device • Developed at the NIOSH research laboratories in Pittsburgh, USA • Precisely replicates results according to the NIOSH 5040 method in real-time • Real-time instant results, no sending filter samples off to labs • Specifically detects DPM via EC measurements • No cross sensitivity to other dusts and aerosols • No more waiting days for results, saves time and money • Battery or AC powered for personal or fixed monitoring • 66.6 day data logging with software provided and FREE updates • Both audible and visual alarms • Easy to change sample / analysis filter ■■WITH 4-20mA OUTPUT Consumables ■■AIRTEC CONSUMABLE KIT Contains 3x Cassettes and 1x Prefilter cartridge 7 AIR SAMPLING GRAVIMETRIC ANALYSIS - AIR SAMPLING PUMPS ESCORT LC AIR SAMPLING PUMP The Escort LC Air Sampling Pump can be used with a variety of personal and area sampling devices to collect such airborne contaminants as asbestos fibers, toxic gases, vapors, particulates, fumes and mists. It can also be used to sample silica dust, coal dust and organic vapors. General Features • Watertight case for occasional water spray • Inlet filter traps particulate matter • Separate LEDs indicate pump operation and low battery • Stainless steel-filled plastic case provides EMI/RFI protection • Exceptionally quiet operation • Includes sampling line and charger • 2 year warranty Accessories ■■LEATHER CASE ESCORT ELF AIR SAMPLING PUMP RENT ME Escort ELF air sampling pumps feature a state of the art electronic laminar flow sensor to provide a constant flow control with ± 2.5% regulation of flow rate (from 1-3 lpm) with automatic compensation for changes in battery voltage, temperature, altitude, and sample load. An internal secondary standard calibrates the pump continuously and needs to be checked against a primary standard only once per month (or every 200 hours for coal mine dust sampling). General Features • Patented electronic laminar flow control • Internal secondary standard calibrates the pump continuously, maintaining OSHA compliance • Check against a primary standard only once a month or every 200 hours for coal mine dust sampling • Inlet filter traps moisture and particular matter • Rated IP66 for resistance to water and dust ingress • Exceptionally quiet operation • Flow-fault Indicator shows any sample inlet blockage • Run/hold feature allows “time out” during sampling process • Elapsed time readout and low-battery warning • Low flow and dual tube sampling available with Gemini Twin-Port Sampler • 2 year warranty Options ■■STANDARD ■■WITH SAMPLING LINE AND CHARGER ■■WITH GEMINI SAMPLER Accessories ■■LEATHER CASE 8 KENELEC.COM.AU / 1300 73 22 33 AIR SAMPLING TSI 4146 PRIMARY CALIBRATOR KIT ZEFON DIGICAL 30 CALIBRATOR KENELEC TECH TIP RENT ME HOW DO I PROPERLY CALIBRATE MY PUMP? When sampling using filter cassettes, the accuracy of your sample collection depends on an accurate amount of air passing through the filter. Filter cassettes create a high amount of backpressure in the sampling ‘train’. So to calibrate the pump airflow properly the sampling ‘train’ must be in a certain order. Airflow must pass though the calibrator first, then through the media, and finally through the pump. By configuring your calibration setup this way, you are measuring the flow rate of air as it enters the filter. The TSI Primary Calibrators are portable, batteryoperated units that are lightweight, easy to use and accurate within 2% of reading. Volumetric flow rate is displayed continuously so adjustments to pump flow can be made in real-time. The LCD display is easy to read. General Features • Range:0.01-20LPM • Accuracy: within 2% • Battery powered, compact and lightweight • NIST traceable calibration certificate Options A primary calibration device, the DigiCal™ Calibrator provides instantaneous calibration for instruments like the Zefon Escort LC Pump or the secondary flow standard inside the Escort ELF Sampling Pumps. Just press the plunger and the DigiCal Calibrator does the work. Its unique flow cell replaces conventional bubble tubes and makes calibration easier. The Digi-Cal Calibrator achieves extreme accuracy by utilizing a computerized flow meter that provides instantaneous flow readouts on a digital display. General Features • Flow rate: 0.1 to 30LPM ■■TSI4046 Flow rate of 2.5 to 300LPM ACCESSORIES FOR SAMPLE PUMPS ZEFON HEAVY DUTY 10MM DORR-OLIVER CYCLONE – FOR MINING - PART# 10044015 Designed to fit all standard 37mm Industrial Hygiene (IH) cassettes the cyclone and holder are designed to orient the cyclone in the proper position for sampling and are fixed with a strong, spiked collar clip so they won’t come off under even strenuous work. ZEFON ALUMINUM CYCLONE FOR RESPIRABLE DUST WITH HOLDER PART# ZA0062 ZEFON 10MM STATIC CONDUCTIVE NYLON CYCLONE WITH HOLDER - PART# ZA0081 This static conductive replica of the 10mm “DorrOliver” Nylon Cyclone eliminates any possible bias in sampling results from static charging. ZEFON UNIVERSAL CASSETTE AND CYCLONE HOLDER - PART# ZA0061 ZEFON INHALABLE DUST SAMPLER WITH CONDUCTIVE PLASTIC CASSETTE A reusable filter cassette with a sampling head designed to measure the worker’s exposure to inhalable particulates and respirable dust. When sampling at the recommended flow rate of 2 LPM, it collects a particle size distribution that includes particles of 100 micron and smaller. This meets the definition set forth by ACGIH AND BRITISH METHOD MDHS 14/3 for inhalable particulate. Options ■■PLASTIC CASSETTE PART# ZA0300 ■■STAINLESS STEEL CASSETTE PART# ZA0303 Cyclones are designed to separate respirable dust particles from non-respirable particles and allow the respirable particles to be collected on a filter cassette. This Zefon cyclone is a replica of the SKC Aluminum Cyclone and is ideal for silica and crystalline. KENELEC.COM.AU / 1300 73 22 33 The Zefon Universal Cassette and Cyclone Holder allows cassettes and cyclones to be attached onto a workers collar. Compatible with 37mm cassettes, 25mm cassettes, and aluminum cyclones manufactured by both Zefon and SKC. 9 AIR SAMPLING PREASSEMBLED AIR SAMPLING FILTER CASSETTES Zefon offers a complete line of 37mm air sampling cassettes manufactured to meet all applicable NIOSH, OSHA, and EPA standards. All 37mm cassette housings are manufactured in-house from polystyrene or polypropylene and are available in two or three piece configurations. All 37mm cassettes are individually assembled and preloaded under stringent quality assurance standards with only the finest quality membrane and support pads. PRELOADED AIR SAMPLING CASSETTES General Features • Supported filter types – MCE, PVC, Polycarbonate, Glass Fibre, PTFE (with PP support), PTFE (Zefluor) with PTFE support, PTFE (pure, unsupported) and Quartz • 25mm and 37mm diameter • 2-piece Sytrene, 3-piece Styrene and Conductive Polypropylene • 50 per box Configurations available to conform with most NIOSH standards that require filter cassettes. GRAVIMETRIC PRE-WEIGHED CASSETTES General Features • 2 or 3 piece housing styles • Preloaded, ready to use • Leak free construction eliminates sample loss • Configurations available to conform with most NIOSH standards that require filter cassettes ENDOTOXIN-FREE CASSETTES STERILE 37MM FILTER CASSETTES Zefon Sterile Endotoxin-Free Cassettes are specially manufactured to ensure there ist no background interference when sampling endotoxins. Each lot is carefully checked and verified by independent laboratories for endotoxins before product is released for shipment. Zefon sterile 37mm filter cassettes are suitable for a wide range of microbiological sampling and analysis including fungi collection, water supply testing and beverage monitoring. Each cassette is carefully assembled in a clean room and then sterilized with gamma radiation. General Features General Features • 0.45µm Polycarbonate filter • 37mm Styrene housing • Sterilized by irradiation • Endotoxin free • 37mm 3pc stryrene housing • Sterilized by gamma radiation • MCE Filters in 0.8 or 0.45 micron pore size • Polycarbonate Filters in 0.2 or 0.4 micron pore size • 50 per box Options ■■PS7345PCEFB CASSETTE • 37mm 3pc 0.4μ Polycarbonate, sterile, 10/box ■■PS7345PCEFC CASSETTE • 37mm 3pc 0.4μ Polycarbonate, sterile, 50/box Options ■■WITH MCE FILTERS ■■WITH POLYCARBONATE FILTERS GRAVIMETRIC MATCH-WEIGHED CASSETTES Inlet Collected Particulate Test Filter Control Filter Support Pad Outlet Gravimetric analysis samples require filters to be weighed both before and after sampling to determine the amount of contaminate collected. Zefon pre-weighed cassettes eliminate the inconvenience of pre-weighing filters by providing the filter weight on each cassette prior to sampling. Zefon match-weighed cassettes eliminate the need to weigh filters before sampling by providing two filters which are matched in weight. The top filter collects particulate and the bottom filter serves as a control. After sampling, both filters are weighed and the difference in weight equals the amount of contaminate collected. General Features Note: The use of match-weighed cassettes overcome the environmental conditions issue as both filters are exposed to the same environmental conditions. Therefore, after sampling, the measured weight difference is solely the amount of contaminate collected. • 2 or 3 piece housing • Preloaded, ready to use • Each cassette labelled with serial number • Colour coded to indicate filter type • 5 Decimal weight accuracy (.00001g) • Use of Pure Homopolymer PVC filters provide excellent weight stability • PVC filters specially designed with no silica and low ash properties Options ■■7P52P CASSETTE • 37mm, 2 pc, 5.0um PVC Gravimetric Pre-weighed - Box of 50 ■■7P53P CASSETTE • 37mm, 3 pc, 5.0um PVC Gravimetric Pre-weighed - Box of 50 10 General Features • 2 or 3 piece housing • Versions available with MCE (0.8um pore size) and PVC (5.0um pore size) filters • Labels with serial numbers provided • Colour coded to indicated filter type and pore size • Preloaded - ready to use • Leak free design Options ■■5M92M CASSETTE • 25mm, 2 pc, 0.8um MCE Gravimetric Matched - Box of 50 ■■7M52P CASSETTE • 37mm, 2 pc, 5.0um PVC Gravimetric Matched - Box of 50 ■■7M53P CASSETTE • 37mm, 3 pc, 5.0um PVC Gravimetric Matched - Box of 50 ■■7M92M CASSETTE • 37mm, 2 pc, 0.8um MCE Gravimetric Matched - Box of 50 ■■7M93M CASSETTE • 37mm, 3 pc. 0.8um MCE Gravimetric Matched - Box of 50 Environmental conditions can have a significant effect on filter weight readings. When using Zefon pre-weighed cassettes, it is important that the post sample weighing is performed under the same environmental conditions used at the Zefon factory. Those conditions are set at a temperature of 68° F (± 1.0°F) and a relative humidity of 50% (± 1%). KENELEC.COM.AU / 1300 73 22 33 AIR SAMPLING UNASSEMBLED AIR SAMPLING FILTER CASSETTES Similar to the preloaded cassettes, Zefon also supply a full range of unassembled cassettes. This includes cassette housings, membrane filters and filter support pads. All components are manufactured in-house to meet stringent quality standards. CASSETTE HOUSINGS Clear Styrene Opaque Styrene All unassembled cassette housings feature a leak free design and are manufactured in-house to the same stringent quality standards that are applied to pre-assembled cassettes. General Features • Leak free design • Available in 25mm and 37mm sizes • Available in 2-piece, 3-piece and 4-piece configurations • Asbestos style (cone outlet) cassette housing also available • Supplied in packs of 50 • Ideal for commercial laboratories that use high volume of cassettes Asbestos Style Options ■■CLEAR STYRENE • The most common material, a crystal clear styrene that provide excellent visibility inside the cassette housing. ■■OPAQUE STYRENE • Manufactured of the same styrene the clear one is, except it is an opaque brown colour to prevent transmission of light into the cassette. ■■POLYPROPYLENE (SOLVENT RESISTANT) • A natural polypropylene with a cloudy looking colour. Material is resistant to a wide range of chemicals. ■■CONDUCTIVE BLACK POLYPROPYLENE • Manufactured using a polypropylene that is carbon filled making it static conductive when grounded properly. MEMBRANE FILTERS FILTER SUPPORTS PADS Options MCE Filter PVC Filter Silver Filter PCTE Filter PTFE Filter Glass Fibre A full range of membrane filters is available from Zefon. These are manufactured in-house to the same stringent quality standards that are applied to pre-assembled cassettes. General Features • Available in MCE, PVC, PCTE, Silver, PTFE and Glass Fibre materials • Pore sizes from 0.2um to 5.0um • Available in 25mm, 37mm and 47mm sizes • Majority supplied in packs of 100 KENELEC.COM.AU / 1300 73 22 33 ■■MCE MEMBRANE FILTERS • Mixed Cellulose Ester (MCE) Filter Membrane Discs are manufactured from a mixture of cellulose acetate and cellulose nitrate. MCE membrane filters are one of the most widely used filters in both air monitoring and analytical applications. ■■PVC MEMBRANE FILTERS • Polyvinyl Chloride (PVC) Membrane Filters (GLA5000) are excellent membrane filters for sampling airborne metals, silica, and dust. Comprised of inherently low ash pure homopolymer PVC, these filters are particularly suited to provided interference-free silica determinations. Low moisture pick-up and low tare weight assure gravimetric stability. ■■POLYCARBONATE MEMBRANE FILTERS • Polycarbonate track-etch (PCTE) membrane filters are manufactured from polycarbonate films. They feature a smooth flat surface, exhibit wellcontrolled pore size and shape, and have very low levels of extractables. Naturally hydrophobic. ■■SILVER MEMBRANE FILTERS • Silver Metal Filter Membranes are pure metallic silver (99.97% pure silver) and are available with particle retention ratings of 0.45 or 0.8 microns. Silver metal membranes are used in a variety of filtration applications, and their ability to withstand extreme chemical and thermal stress makes them ideal for applications involving aggressive fluids and/or high temperatures. ■■PTFE MEMBRANE FILTERS • PTFE membrane filters provide excellent chemical resistance and are suitable for use in the most aggressive sampling environments. ■■GLASS FIBRE FILTERS • Zefon glass microfiber filters are produced from 100% borosilicate glass microfiber without the use of binders or strengthening agents. The fibers used to manufacture these depth filters are smooth and uniform. This permits their characteristically high flow rates while allowing retention of exceptionally small particles and high load capacity. These characteristics are particularly important in applications involving high concentrations of particulate. Zefon manufacture a range of filter support pads. These filter supports are used behind filter membranes to support them from collapsing while still allowing free air flow through them. General Features • Available in cellulose, porous plastic and stainless steel grids • Available in 25mm and 37mm sizes, stainless steel grid also available in 47mm size • Supplied in packs of 100, stainless steel filter supports are sold as individual units Options ■■CELLULOSE • Cellulose pads are made up of 100% pure cellulose and the most common support used in filter cassettes. ■■POROUS PLASTIC • Porous plastic supports work well when sampling chemicals that are not compatible with cellulose. ■■STAINLESS STEEL GRIDS • Stainless steel grids can be used in a wide range of filter holders and can easily be cleaned and re-used. 11 AIR SAMPLING DUSTTRAK - AEROSOL MASS CONCENTRATION MEASUREMENT DustTrak: Real-Time, Laser based monitors for OHS professionals. The DustTrak measures aerosol contaminants such as dust, smoke, fumes and mists, giving you real-time aerosol mass readings. You can measure PM1, PM2.5, PM4 & PM10 one at a time or simultaneously depending on the model. TSI 8532 DUSTTRAK II PORTABLE DUST MONITOR TSI 8530 DUSTTRAK II PORTABLE DUST MONITOR RENT ME RENT ME Measures PM fractions one at a time Measures PM fractions one at a time General Features General Features • 100nm to 10μm particle size range • 1ug/m3 to 400mg/m3 dust concentration range • 6600mA rechargeable lithium ion battery • 37mm filter sample collection capabilities • Large VGA 5.7” colour touch screen • Measures all PM fractions (one at a time) • 66,000 point data logging & software • 100nm to 10μm particle size range • 1ug/m3 to 400mg/m3 dust concentration range • 3600mA rechargeable lithium ion battery • 66,000 point data logging & software • Large VGA colour graphical display • Packed full of popular features TSI 8534 DUSTTRAK PORTABLE DUST MONITOR TSI 8533 DUSTTRAK PORTABLE DUST MONITOR RENT ME Measures PM fractions simultaneously RENT ME Measures PM fractions simultaneously General Features General Features • 100nm to 15μm particle size range • 1ug/m3 to 150mg/m3 dust concentration range • 3600mA rechargeable lithium ion battery • 66,000 point data logging & software • Measures all PM fractions (simultaneously) • Large VGA colour graphical display • Packed full of popular features • 2 year warranty • 100nm to 15μm particle size range • 1ug/m3 to 150mg/m3 dust concentration range • 6600mA rechargeable lithium ion battery • 37mm filter sample collection capabilities • Large VGA 5.7” colour touch screen • Measures all PM fractions (simultaneously) • 66,000 point data logging & software 12 KENELEC.COM.AU / 1300 73 22 33 AIR SAMPLING PARTICLE COUNTING Detecting the root cause of complaints can often come down to being able to find and measure the presence of a pollutant - signal by the level of particles in a particular area. TSI 8525 P-TRAK REAL-TIME ULTRAFINE PARTICLE COUNTER TSI 3007 ULTRA-FINE PARTICLE COUNTER TSI 9306 PORTABLE PARTICLE COUNTER RENT ME RENT ME* General Features General Features General Features • 2 nm to 1μm wide particle size range • Ideal for indoor air quality and OH&S applications • Terrific in detecting combustible aerosol sources • Sample Flow Rate - 100 cm3/min • Concentration Range - 0 to 5 x 105 particles/cm3 • Audible and visual particle detection alerts • Fully serviced and supported in Australia • 2 year warranty • 10nm to 1μm wide particle size range • Ideal for indoor air and OH&S work • Menu driven, easy to use • USB interface, data logging and software • Audible and visual particle detection alerts • Packed full of other features • 0.3μm to 25μm particle size range • 2.8 lpm flow rate with built-in pump • 10,000 point data logging with software included • USB & Ethernet interfaces, HEPA filtered output • Colour LCD display, 6 hour lithium ion battery • 2 year warranty Options ■■TSI 9306-03 These particle counters are calibrated with NIST traceable PSL spheres using TSI’s world-class Classifier and Condensation Particle Counters, the recognized standard for particle measurements. Backed with a standard two-year warranty and TSI’s long-standing reputation for high quality, there are no other handheld particle counters like it on the market today. • 6 Fixed size channels with the channels set at 0.3μm, 0.3μm, 0.5μm, 7μm, 1.0μm, 2.0μm & 5.0μm ■■TSI 9306-04 • 6 Fixed size channels with the channels set at 0.3μm, 0.5μm, 1.0μm, 3.0μm, 5.0μm & 10μm ■■TSI 9306-V2* (RENT ME) • 6 user selectable size channels from 0.3μm to 10μm NANOPARTICLE SURFACE AREA MONITOR TSI 3550 Recent research has shown that the surface area of nanoparticles is highly correlated to exposure related adverse health effects. The Model 3550 indicates the surface area of nanoparticle aerosols that deposit in the lung. The reported measurements correspond to the ICRP lung deposition curves for the tracheobronchial (TB) and alveolar (A) regions of the human respiratory tract. General Features • Selectable measurement modes for tracheobronchial (TB) or alveolar (A) deposition response • Comprehensive software for collection, storage, and display of running-average, time-weightedaverage (8-hour), or total deposited surface area • Simple operation, fast set up, and the ability to run continuously for unattended, long-term exposure monitoring • Sensitivity down to 10 nm • Over five decades of concentration, from 0 to 10,000 μm2/cm3 spanning a wide range of exposure dosages • Data rate of one measurement per second detects short periods of high-intensity exposures KENELEC.COM.AU / 1300 73 22 33 13 ASBESTOS ABATEMENT SAMPLING PUMPS BUCK LIBRA L4 ABATEMENT SAMPLING PUMP The Buck LIBRA™ is a low cost, high performance, CONSTANT FLOW personal sampling pump. Designed for use with asbestos and lead abatement, the LIBRA provides full constant flow compensation using 25mm and 37mm cassettes. With a rugged, compact design, the sealed pump case protects the internal components from dust, fibers and moisture. Includes a rechargeable NiMH battery with available one-hour charger. Easy to operate with “Set it and Forget it” flows at 2.0, 2.5 & 3.0 LPM; maintained within ±5% for full constant flow compensation using 37 and 25mm cassettes interchangeably, ensuring accurate sample volumes based on the run time. The BUCK Libra™ L-4 is capable of delivering up to 4.0 LPM for periods exceeding 8 hours. Bright LED’s indicate the pump is ON, Flow Fault or a Low Battery. Flow from 5 to 800 cc/min may be obtained using optional Low Flow Holder. General Features Options • Compact, rugged and quiet • No tools required to change flow rates • Flow setting is saved in memory for next day quick start • Battery pack rechargeable while attached or separately • Stainless steel belt clip with built-in tripod connector • One-hour rechargeable batteries and extended run triple packs • High impact steel fiber filled Lexan case, antistatic and RFI shielded • “Auto-restart” within one minute of a flow fault • Flows up to 4 LPM for special cyclone requirements • Low flows, 5 to 800 cc/m, with optional Universal Low Flow Sorbent Tube Holder • High backpressure capable for 25mm 0.45μ micron asbestos filters • Built in washable stainless steel 100 micron filter for economy of use • One year warranty ■■APB-926020 • Pump with charger ■■APB-942600 • Pumps 5 pack with 5 charger station and a durable hard plastic 1500 Pelican case ■■APB-109030 • Adjustable universal low flow holder Zefon high volume diaphragm area sampling pumps are economical workhorses. Each pump comes with a locking flow control valve, hose barb, 10’ tubing and on/off switch. Suitable for sampling a large area, for example a room. Accessories AREA SAMPLING PUMPS General Features High Volume Diaphragm Pump • Ultra high volume 23 stroke diaphragm pump • Includes flow control valve and tubing • Suitable for use with Air-O-Cell Cassettes, PCM and TEM Cassettes • Available as a single pump or a 2 pump kit. The 2 pump kit includes 2 pumps, 2 sampling stands, tubing and a heavy duty carrying case ■■ZA0042 - STAND, CASSETTE, ECONOMY ■■ASB-1 - STAND, CASSETTE, DELUXE ■■ZA0005 – ADAPTER, LUER, PLASTIC • Use to attach cassette to ¼” tubing, 10/PK ■■459743 - COUPLER, METAL LUER • Use to attach cassette to ¼” tubing, 3/PK ■■ZA0064 - TUBING • Tygon 1/4” ID, 50 feet Options ■■ZTHV01-220V • Pump, Zefon Diaphragm, 220VAC ■■ZTHV01-KIT-220V KIT • Zefon Diaphragm 2 Pump Kit, 220VAC 2 Pump Kit FIELD ROTAMETER CALIBRATOR FOR SAMPLING PUMPS Zefon Field Rotameters are a low cost way to measure airflow in air sampling applications. They feature a durable acrylic housing with direct reading scales printed on them. These are available in three different flow ranges covering a range of 0.2 through 30 LPM. Operation and maintenance are very simple; only a few common sense precautions must be observed to assure long, trouble-free service. Options ■■116116 - ROTAMETER, 0.2-4 LPM ■■195380 - ROTAMETER, 1-20 LPM ■■195505 - ROTAMETER, 3-30 LPM Each flowmeter is supplied with 1 hose barb, tubing, and luer connecter. 14 KENELEC.COM.AU / 1300 73 22 33 ASBESTOS ASBESTOS SAMPLING CASSETTES & ACCESSORIES ASBESTOS 25MM AIR SAMPLING CASSETTES ASBESTOS BULK SAMPLING EQUIPMENT Zefon Cutter Sleeve Zefon T-Handle Zefon PCM & TEM 25mm air sampling cassettes are designed and manufactured to meet all applicable NIOSH, OSHA, and EPA standards. The cassette housings are injection moulded in-house and are individually assembled and preloaded under stringent quality control standards. Once assembled, each cassette is individually tested prior to packaging for shipment. Random lot sample testing is performed daily by an independent laboratory to ensure low background fibre counts. Laboratory results are available upon request. General Features • Quality 0.8um MCE filter material with or without grids (PCM models) • Quality 0.45um + 5.0um MCE filter material (TEM models) • 2” Static conductive extension cowl • Meets NIOSH 7400/7402 specifications • Meets AEHRA requirements (TEM model) • Each cassette is marked with a unique serial number • Preloaded - ready to use Options ■■Z008BA - CASSETTE • 25mm, 3 pc, 0.8um, MCE (Box of 50) ■■Z008GA - CASSETTE • 25mm, 3 pc, 0.8um, MCE with grid (Box of 50) ■■Z008GGA - CASSETTE • 25mm, 3 pc, 0.8um MCE with green grid (Box of 50) ■■Z012BS - CASSETTE • 25mm, 3 pc, 1.2um, MCE, with white shrink band (Box of 50) ■■Z012GS - CASSETTE • 25mm, 3 pc, 1.2um, MCE with grid with white shrink band (Box of 50) ■■Z045BA - CASSETTE • 25mm, 3 pc, .45um & 5.0um MCE (Box of 50) ■■Z008PC - CASSETTE • 25mm, 3 pc, 0.8um polycarbonate (Box of 50) Zefon provide their own cutter sleeves and handles for asbestos bulk sampling. The 3” Steel Sampling Modules (cutter sleeves) are extremely strong and durable. They are more robust than similar modules manufactured from copper. Compatible with the Zefon solid aluminium T handle or the EMS T handle. In addition, the Wonder Makers Asbestos Bulk Sampling set is a great option. This is the safest, most efficient way to collect bulk samples and project a professional image. It makes the way inspectors have been taking samples obsolete. This small compact device uses individual cutter sleeves in airtight transport containers for maximum safety and accuracy. General Features (Wonder Makers WM10) • Includes rugged carrying case with fold-down handle and positive grip latch, two handles, two plungers, and 100 cutter sleeves in clear slim vials with caps • Eliminates cross-contamination • Easy to operate • Ends the need for protective equipment during sampling • Encourages full-depth samples • Complies with OSHA asbestos regulations • Also available in a double-length set without case – WM11 Options Zefon Asbestos Bulk Sampling ■■ZA0070 • Asbestos bulk sampling modules (cutter sleeve), 3” length, case of 100 ■■ZA0071 - ZEFON T-HANDLE, SOLID ALUMINUM Wonder Makers Asbestos Bulk Sampling ■■WM10 - BULK SAMPLING STARTER SET ■■WM11 - DOUBLE LENGTH BULK SAMPLING STARTER SET • Without case ACETONE VAPORIZERS PERM-O-FIX ACETONE VAPORIZER The ZA0191 is a simple, easy to use, acetone vaporizer for use in preparing asbestos PCM samples as per NIOSH 7400. Includes vaporizer only. Available in 120VAC and 220VAC models. Options ■■ZA0191 - PERM-O-FIX ACETONE VAPORIZER, 230VAC SMALL WONDER ACETONE VAPORIZER The Small Wonder Acetone Vaporizer Kit includes everything needed to clear slides for PCM analysis. General Features • Small Wonder acetone vaporizer with built-in heat control, temperature gauge, and cool cover; 2 oz. acetone; 1/2 oz. triacetin; 1/2 gross microscope slides; cover slips; tweezers; microdropper; syringe; #10 round blade scalpel; pre-cut foam padding; durable plastic carrying case with handle; instruction manual • Padded carrying case protects equipment and supplies • Detailed instruction manual • Enough supplies for the analysis of 1/2 gross of slides • Lightweight but solidly built • Designed in strict compliance with the NIOSH 7400, 7402, or ORM requirements for preparation of microscope slides for PCM analysis Options ■■WM42 - SMALL WONDER ANALYSIS KIT KENELEC.COM.AU / 1300 73 22 33 15 MICROBIAL SAMPLING BIO PUMP SAMPLING ZEFON BIO PUMP PLUS Ideal for indoor air quality sampling, mould spores, bio aerosols, pollen, fibres and inorganic particulates. The Zefon Bio-Pump® Plus is the smallest and lightest portable battery powered IAQ sampling pump available. It provides the simplest and most convenient way to sample with Air-O-Cell® and ViaCell® cassettes at a flow rate of 15LPM. General Features • Extra long battery life - Take over 100 samples on a single charge • Programmable timer allows unattended operation • Quick-charge battery charger included (approx 3 hours) • Nothing to prepare or clean. Just place the cassette on the pump, set the time and go • Each pump comes complete with both an Air-OCell® and Via-Cell® flow indicator, quick charger, 10 free Air-O-Cell® cassettes and a handy carrying case Options ■■ZBP-200 • Bio Pump Plus with 230 VAC charger ■■ZBP-200-CKIT • Bio Pump Plus with TSI Calibrator Acessories ■■BIO PUMP REMOTE EXTENSION TUBE ■■FILTER, BIO PUMP BIOISOLATION ■■TRIPOD STAND - HEAVY DUTY SAMPLING CASSETTES AND MEDIA FOR BIO PUMP Zefon manufactures a complete Family of IAQ sampling cassettes to meet demanding situations AIR-O-CELL CASSETTES VIA-CELL SAMPLING CASSETTES Optical microscopy Air-O-Cell sets the standard for particle capture and optical analysis. General Features • The ultimate multipurpose cassette for: • Bio aerosols: mould spores, pollen, insect parts, skin cell fragments, asbestos, fibreglass, cellulose, clothing fibres, synthetics, IAQ sampling • Inorganic particulate: ceramic, fly ash, copy toner, oil droplets, paints, rust, salts, products of combustion Options ■■AOC010 - BOX OF 10 ■■AOC050 - BOX OF 50 16 AIR-O-CELL CSI CASSETTES Culture and PCR The Via-Cell® bioaerosol sampling cassette is designed to collect both viable and non-viable bioaerosols, maintain viability of the viable mold spores and prevent growth during transport to the laboratory. Sampling with the Via-Cell® is very similar to its sister product Air-O-Cell®. Simply connect it to any pump calibrated to 15LPM and run your sample. The key to the Via-Cell® is that the media used for collection maintains viability of spores and allows several analysis options including culturing, PCR analysis and microscopy. Options ■■VIA010 - BOX OF 10 Optical, SEM & X-Ray analysis Air-O-Cell CSI brings the advantages and precision of SEM particle analysis with x-ray chemical analysis to indoor air quality investigations. General Features • Samples can be tested and re-tested using optical, scanning electron microscopy (SEM) and x-ray analysis in any order without significant particle loss or complex sample preparation • Applications include indoor air quality, home inspection, floor inspection, stack emissions, allergy testing, clean room monitoring and fibre analysis Options ■■CSI010 - BOX OF 10 KENELEC.COM.AU / 1300 73 22 33 MICROBIAL SAMPLING OTHER SAMPLING TECHNOLOGIES BIO-TAPETM TEDLAR GAS SAMPLING BAGS Bio-Tape™ provides a standardized surface sampling method used for the determination of possible microbial, bioaerosol, and inorganic dust contamination. Quickly take a sample and measure the relative degree of contamination. It is especially useful when sampling valuable or nontransportable materials and is very effective on smooth areas. Bio-Tape consists of a flexible plastic microscope slide with a pre-defined adhesive area. A center-line marker on the slide aids the user in locating the center when taking the sample and also aids the laboratory analyst. Each slide is provided with a unique serial number for traceability and packed in a slide mailer to prevent cross contamination. Bio-Tape is compatible with both optical microscopy and scanning electron microscopy (SEM). This provides the ability to perform optical and SEM analysis along with an x-ray analysis on the exact same air surface sample and exact same particles. General Features • Provides sample consistency • Individually serialized for traceability • Prevents cross contamination • Requires less laboratory prep time • Eliminates problems of placing tape in a zip bag, or broken glass slides • Samples may be archived by the laboratory for later review Options ■■BT0025 SLIDES - 25 IN A BOX ■■BT0050 SLIDES - 50 IN A BOX ■■BT0500 SLIDES - 500 IN A BOX Gas sample bags, usually called Tedlar Bags, are a convenient way to collect gas and vapour samples in air. Many chemical hazards can be effectively collected by sample bags, allowing easy transport to the laboratory for testing. Zefon EconoGrab™ gas sampling bags are excellent quality, low-cost tedlar® gas sampling bags that feature a choice of a single polypropylene fittings or stainless steel fitting. General Features • Chemically inert Tedlar® film • Reusable if purged with nitrogen • Easy storage and handling Applications • Grab sampling • Indoor air sampling • Gas blending • Assessing exposures from leaks and spills • Leaky underground storage tanks • Sampling from vents or flues • Hazardous waste site sampling • Measuring anesthetic gases in operating rooms • Stack sampling • Soil gas sampling • Calibration gas standards • Ground water testing Options EconoGrab™ Tedlar bags come with a choice of a single polypropylene fittings (suitable for use in most applications) or stainless steel fitting (for use when sampling compounds that are not chemically inert to polypropylene.) Using Bio-Tape™ helps provide more consistency in your samples. This is because each sample uses the same amount of adhesive surface area and the provided packaging offers protection during shipment to the laboratory. When the laboratory receives your sample, there will be no guessing where the sample area is and no sticky mess of tape to deal with. ■■0.5 L ■■1.0 L ■■3.0 L ■■5.0 L ■■10.0 L ■■25 L ■■50 L ■■100 L BUCK BIO CULTURE MICROBIAL AIR SAMPLER The Bio-Culture™ air sampler is the smallest, most cost effective and easiest to use sampler available for microbial air sampling. The Bio-Culture™ air sampler features a selectable, continuous, constant sample flowrate and is simple to operate. No tools are required. Its quiet operation allows unobtrusive sampling in a variety of applications. Selecting the appropriate air sampling device is an important step in preserving the quality of your work environment. Think carefully about your workflows and consider all features of a microbial air sampler to ensure you receive a product that delivers what you require without compromising your environment. General Features Options ■■BIO-CULTURE CALIBRATION HEAD • The Bio-Culture™ calibration head is a NIST traceable venturi calibrator within 1% accuracy that allows users to calibrate the flow of the BioCulture pump themselves without having to send the pump out for service or calibration. • Allows flow calibration at flow rates between 30-120LPM • Designed for use with impeller fan type pumps like the Bio-Culture, which require calibration devices with very little backpressure resistance • Provided with a certificate of calibration traceable to NIST standards • Flow rate - 30-120LPM (user adjustable) • Uses standard 90mm petri dishes • Sampling head design of 380 1mm diameter holes • Battery powered - runs for 6-8 hours (depending on flow rate, battery maintenance and backpressure) • Tripod mounting threads on bottom of unit - allows 90 degree sampling • Sampling head may be sterilized by autoclave or gas torch • Built-in timers of 1, 2, 5, and 10 minutes • Optional calibration head allows field calibration of flow rate with a NIST traceable calibrator KENELEC.COM.AU / 1300 73 22 33 17 INDOOR AIR QUALITY & GAS MONITORING INDOOR AIR QUALITY Providing a comfortable, safe and healthy indoor environment is an increasingly important concern. Good indoor air quality increases concentration and productivity which can reduce lost days due to absence. A good indicator of proper ventilation is the level of CO2 present in a space. Carbon dioxide is a normal by-product of occupant respiration. Elevated levels of CO2 may indicate that additional dilution ventilation is required. TSI 7515/7525/7545 IAQ-CALC METERS TSI IAQ-Calc™ Meters are outstanding instruments for investigating and monitoring indoor air quality (IAQ). Handheld, easy to use allowing you to gather your data and work with ease. CO2 General Features CO • Conduct IAQ evaluations • Determine thermal comfort • Examine building IAQ conditions to optimize worker productivity • Comply with regulations and guidelines • Model 7515 is a cost-effective meter for carbon dioxide (CO2) measurements. • Models 7525 and 7545 simultaneously measure and data log multiple parameters. Model 7525 measures CO2, temperature, humidity, and calculates dew point, wet bulb temperature, and percentage outside air. • Model 7545 adds detection of carbon monoxide (CO). Temperature ✓ ✓ Humidity ✓ ✓ Percentage outside air ✓ ✓ Dew point ✓ ✓ Wet bulb temperature ✓ ✓ Data logging/ downloading ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Options ■■TSI 7515 • CO2 & statistics display ■■TSI 7525 • CO2, temp, humidity, data logging ■■TSI 7545 • CO2, temp, humidity, CO, data logging 7515 7525 ✓ ✓ ✓ ✓ ✓ Statistics Review data Certificate of Calibration ✓ 7545 ✓ Available Unavailable TSI 7575 PLUG AND PLAY MULTIFUNCTION IAQ MONITOR TSI’s Q-Trak™ IAQ Monitor is a handheld, multi-function test instrument which features a menu-driven user interface for easy operation and provides quick, accurate information to measure and assess key IAQ parameters. TSI 7575 PLUG AND PLAY MODEL The TSI 7575 offers outstanding versatility with its “plug and play’ feature – simply change the probe over to suit the monitoring you are doing. CHOOSE THE PROBES THAT SUIT YOU The standard 7575 monitor comes with the 982 Probe – right from the beginning you’re all set to measure temperature, humidity, CO2 and CO. If you need to do other measurements such as VOCs switch over to one of the other optional VOC probes. General Features • One instrument with multiple plug-in probe options including VOCs and air velocity • Simultaneously measures CO2, CO, temperature and humidity with 982 probe • Displays up to 5 measurements • On-screen messages and instructions • Store up to 39 days of data collected at oneminute log intervals • TrakPro™ Data Analysis Software provided for data logging, analysis and documenting results • Bluetooth communications for transferring data or remote polling keypad lockout to prevent tampering during unattended use RENT ME 18 Options ■■7575 MULTI FUNCTION METER • Including 982 Probe ■■7575-X MULTI-FUNCTION • IAQ meter only, no plug-in probes Probes ■■980 IAQ PROBE • CO2, temperature, humidity ■■982 IAQ PROBE • CO2, temperature, humidity, CO ■■960 AIR VELOCITY PROBE • Velocity, temperature ■■962 AIR VELOCITY PROBE • Velocity, tempearture (articulated) ■■964 AIR VELOCITY PROBE • Velocity temperature, humidity ■■966 AIR VELOCITY PROBE • Velocity, temperature, humidity (articulated) ■■984 VOC PROBE • 10-20000 PPB, temperature ■■985 VOC PROBE • 1-2000 PPM, temperature ■■986 IAQ PROBE • VOC 10-20000 PPB, CO2, temperature, humidity ■■987 IAQ PROBE • VOC 1-2000 PPM, CO2, temperature, humidity ■■995 ROTATING VANE PROBE • 100 mm, velocity, temperature ■■792 SURFACE TEMPERATURE PROBE ■■794 AIR TEMPERATURE PROBE ■■800681 IAQ PROBE STAND KENELEC.COM.AU / 1300 73 22 33 INDOOR AIR QUALITY & GAS MONITORING PORTABLE GAS MONITORS YESAIR 8 CHANNEL PORTABLE IAQ MONITOR YES PLUS LGA 15 CHANNEL IAQ MONITOR General Features General Features • Measures temperature & humidity standard • Plug in up to 5 other gas sensors anytime • Up to 26 other sensors to choose from • 1 million point data logging with software • Highly accurate 12 bit resolution results • Includes a built-in sample draw pump • Measures temperature & humidity standard • Plug in up to 12 other gas sensors anytime • 26 popular sensors to choose from • 1 million point data logging with software • Highly accurate 12 bit resolution results • Sample using internal pump or by diffusion Options ■■CARBON MONOXIDE (CO) SENSOR (0 - 50 PPM) ■■CARBON MONOXIDE (CO) SENSOR (0 - 50 PPM) • H2 compensated for use in H2 background ■■NITROGEN DIOXIDE (NO2) SENSOR (0 - 5 PPM) ■■NITRIC OXIDE (NO) SENSOR (0 - 100 PPM) ■■ETHYLENE (C2H4) SENSOR (0 - 500 PPM) ■■ETHYLENE OXIDE (C2H4O) SENSOR (0 - 20 PPM) ■■OXYGEN (O2) SENSOR (0 - 25% VOLUME) ■■OZONE (O3) SENSOR (0 - 1 PPM) ■■AMMONIA (NH3) SENSOR (0 - 50 PPM) ■■CHLORINE (CL2) SENSOR (0 - 5 PPM) ■■CHLORINE DIOXIDE (CLO2) SENSOR (0 - 1 PPM) ■■HYDROGEN (H2) SENSOR (0 - 1,000 PPM) ■■HYDROGEN SULPHIDE (H2S) SENSOR (0 - 50 PPM) ■■HYDROGEN CHLORIDE (HCL) SENSOR (0 - 30 PPM) ■■HYDROGEN CYANIDE (HCN) SENSOR (0 - 100 PPM) ■■HYDROGEN FLUORIDE (HF) SENSOR (0 - 10 PPM) ■■SULPHUR DIOXIDE (SO2) SENSOR (0 - 20 PPM) ■■FORMALDEHYDE (CH2O) SENSOR (0 - 10 PPM) ■■ARSINE (AsH3) SENSOR (0 - 2 PPM) ■■FLUORINE (F2) SENSOR (0 - 2 PPM) ■■PHOSPHINE (PH3) SENSOR (0 - 1 PPM) ■■SILANE (SiH4) SENSOR (0 - 1 PPM) KENELEC.COM.AU / 1300 73 22 33 Infrared Sensor ■■CARBON DIOXIDE (CO2) SENSOR (0 - 5,000 PPM) ■■CARBON DIOXIDE (CO2) SENSOR (0 - 10,000 PPM) ■■CARBON DIOXIDE (CO2) SENSOR (0 - 20% VOLUME) ■■CARBON DIOXIDE (CO2) SENSOR (0 - 5% VOLUME) ■■CARBON DIOXIDE (CO2) SENSOR (0 - 100% VOLUME) Catalytic Sensor ■■COMBUSTIBLE GAS (e.g. CH4, H2, C3H8) SENSOR (0 - 100% LEL) •Please specify at time of order PID Sensor ■■TVOC SENSOR (0 - 300 PPM) ■■TVOC SENSOR (0 - 30 PPM) 19 INDOOR AIR QUALITY & GAS MONITORING GAS DETECTION CONTROLLERS - CONNECT THE SENSOR YOU NEED PDC MULTI-CHANNEL CONTROLLER DST DIGITAL TRANSMITTER GEM-II ANALOG MULTI PURPOSE TRANSMITTER INCORPORATES “SMART” SENSOR TECHNOLOGY General Features General Features General Features • For up to 8 analog transmitters and up to 120 digital transmitters. • Up to 32 channels on base controller, expandable to 128 channels • RS485 communication with digital transmitters • Eight 5-amp SPDT relays • Optional analog inputs (up to eight) • Optional BACnet® output module • Audible & visual alarms • LCD Display • Optional Watertight enclosure • Detects a wide range of gases, including solid state and electrochemical • Designed for use with the PDC controller • RS485 digital output signal • RoHS compliant circuit boards • Configured for four wire multidrop wiring • Thermal resetting fuse • LED indication for Power, Fail and Alarm • Single or dual channel • Two 5-amp SPDT relays • Integral plug-and-play “smart” sensors or remote sensors • 4-20mA linear output signal • Analog Transmitter • CSA, UL & C-Tick certification • LED light indicators • Optional 4 digit display • Optional Water tight enclosure GEM MRI OXYGEN SAMPLING TRANSMITTER PET BACNET DIGITAL TRANSMITTER LPT LOW POWER TRANSMITTER INTEGRATE TO YOUR BUILDING MANAGEMENT SYSTEM GEM-MRI is a self-contained oxygen (O2) monitoring system developed for Magnetic Resonance Imaging (MRI) room applications for hospitals and clinics. General Features General Features General Features • Digital transmitter • Single or dual gas sensor • Includes temperature sensor • Tri-color LED light indicator • Communicates via BACnet protocol MS/TP. • Thermal resetting fuse • Analog transmitter • Single sensor: carbon monoxide (CO) 0-200 PPM or nitrogen dioxide (NO2) 0-10 PPM • Linear 4-20 mA output • 2-wire loop, 3-wire VDC or 4-wire VAC power • Automated calibration • Easy installation AST-I INDUSTRIAL ANALOG TRANSMITTER • Sample draw pump • Two 5-amp SPDT relay • Dry contact relays for control of remote devices • Analog output (4-20mA) • Audible alarm • Adjustable flow meter LPT-A LOW POWER TRANSMITTER WITH LCD LOW POWER, LOW COST WIDE RANGE OF GAS SENSORS General Features • Analog transmitter • Single Sensor; supports a wide range of sensors including electro-chemical, solid state and catalytic (refer to table) • 3-wire VDC or 4-wire VAC power • 24 volt DC or AC power (nominal) • Linear 4-20mA or 0-10 volt output signal • Graphic LCD display (user selectable function) • 1 dry contact relay, 30 volt 2 amp maximum • Standard water/dust tight, corrosion enclosure (drip proof) • Audible alarm • Automated calibration procedure • Optional splash guard, heater, and logger 20 LOW POWER, LOW COST – GREAT FOR BULK PURCHASES! AST-IS STANDARD CO2 TRANSMITTER AESTHETIC HOUSING FOR OFFICE & RESIDENTIAL USE. INFRARED GAS DETECTORS General Features General Features • Dual temperature compensated pyroelectric infrared detectors • Lower power consumption • Target gases include CO2 (0-5, 0-20,0-100%) and Methane CH4 (0-100% of volume or 0-100% LEL) • Water/dust tight/corrosion resistant polycarbonate enclosure • Linear 4-20mA output • Measurement ranges from 0-1000 PPM • Attractive PVC enclosures ideal for indoor use eg, residential, schools & offices • Linear 4-20mA or 0-10VDC output • Single internal infrared CO2 sensor, 0 - 2,000 ppm • Optional LCD Display • Optional temperature display • Optional audible alarm • Optional relay AST-IS INDUSTRIAL CO2 TRANSMITTER ART INFRARED REFRIGERANT TRANSMITTER CHILLER ROOM OR FREEZER OPTION INFRARED CO2 DETECTOR General Features General Features • Duct Mount option in IP54 enclosure, Wall Mount option in IP65 enclosure • Linear 4-20mA or 0-10VDC output • Single internal infrared CO2 sensor, 0 - 2,000 ppm OR 0-4% • Optional LCD Display • Optional relay • Use accurate infrared sensors • Detect a wide range of refrigerants • Audible & visible alarms • Standalone or connect to BMS KENELEC.COM.AU / 1300 73 22 33 INDOOR AIR QUALITY & GAS MONITORING CHOOSE YOUR SENSOR FOR YOUR TRANSMITTER CALL KENELEC FOR ASSISTANCE Ensure that all required products are included to make a complete system e.g: ✓ Available Unavailable G EM G -I as I M D u et lti ec -P to ur r po G se EM Sa M m R pl I O in x g yg Sy e st n ( PE em O 2 ) T Tr BA an C sm ne itt t ® er AS T Tr -I I an nd sm us itt tria er l An al AS og T(C IS O C 2) a Tr rbo an n sm D itt iox AR er ide T Tr In an fr sm are itt d R er e LP fr ig T er Tr Lo an an w t sm P o itt w er er LP T Po -A w An er al Tr og an ue sm L D itt ow ST er Tr D an ig sm ita itt l er • LPT and LPT-A transmitters work with PDC Controllers • DST transmitters work only with PDC controllers • PET transmitters work with BACnet control devices Sensors ✓ ✓ Ammonia (NH3) Carbon monoxide (CO) ✓ Carbon Dioxide (CO2) Chlorine (Cl2) ✓ ✓ ✓ ✓ Ethylene (C2H4) Ethylene oxide (C2H4O) ✓ ✓ Formaldehyde (CH2O) Hydrogen (H2) Hydrogen sulphide (H2S) Hydrogen chloride (HCl) Hydrogen cyanide (HCN) Methane (CH4) Nitrogen dioxide (NO2) Nitric oxide (NO) Oxygen (O2) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Ozone (O3) Phosphine (PH3) Silane (SiH4) Sulphur dioxide (SO2) Combustibles Solid State / Semi-Conductor Sensor ✓ ✓ ✓ ✓ 0-2000ppm ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 0-1032ppm 0-2000ppm ✓ ✓ ✓ ✓ Refrigerant (R11) Refrigerant (R12) Refrigerant (R22) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Refrigerant (R114) Refrigerant (R123) Refrigerant (R134A) Refrigerant (R401A) Refrigerant (R401B) Refrigerant (R402A) Refrigerant (R404A) Refrigerant (R407C) Refrigerant (R408A) Refrigerant (R409A) Refrigerant (R410A) Refrigerant (R422A) Refrigerant (R422D) ✓ Refrigerant (R500) Refrigerant (R502) Refrigerant (R507) Refrigerant (R507A) TVOC (0-500ppm) Catalytic Sensor Hydrogen (H2) Methane (CH4) Propane (C3H8) KENELEC.COM.AU / 1300 73 22 33 21 HOSPITALS & LABS PRESSURA ROOM PRESSURE PRODUCTS TSI PRESSURATM Monitor and change high & low pressure rooms TSI PresSura™ Healthcare Room Pressure products help provide safety in isolation rooms, operating rooms, and other specialized spaces, by continually measuring room pressure and indicating room conditions. The PresSura products assist hospitals and engineers to comply with relevant ASHRAE, AIA, CDC and USP standards. TSI’s unique thermal-based pressure sensor offers the most precise, accurate, and stable measurement. Over 50,000 hospital rooms in leading healthcare facilities rely on TSI products every day to provide effective 24/7 monitoring. Safety & Compliance Whether designing or managing healthcare facilities, you understand that safety, compliance and infection prevention are crucial considerations. PresSura Room Pressure products provide the confidence you need to comply with major industry guidelines and regulations in order to ensure and document safe environments. Specifically designed for hospital applications, PresSura Room Pressure Products offer: • Best-in-class measurement of low pressures to help monitor critical pressurized rooms • Simplified compliance with relevant parts of the following guidelines and regulations • ANSI/ASHRAE/ASHE Standard 170-2008, ventilation of health care facilities • The Facility Guidelines Institute (FGI), 2010 Guidelines for Design and Construction of Health Care Facilities • Centers for Disease Control (CDC), Guidelines for Environmental Infection Control in Health Care Facilities • Seamless integration into Building Automations Systems (BAS) where data can be logged and tracked over long periods of time • Low maintenance and easy calibration Through-the-Wall Sensor General Features Options • Both monitor and control units available • Includes room pressure, ventilation and temperature controls • Supports high accuracy through-the-wall pressure sensor based on thermal anemometry • Provides best-in-class accuracy, resolution and stability • Also supports pressure transducer input • Suitable for Airborne Infection Isolation (AII) rooms and Protective Environment (PE) rooms • Positive / negative / no Isolation room modes • Changeable via keyswitch and password protected touchscreen • Supports visual and audible alarms • Programmable alarms delays to avoid nuisance alarms and alarm mute feature. • Standard communication options supported are Modbus & BACnet MS/TP • LonWorks available as an option • Accepts flow, door switch, temperature and relative humidity inputs • Supports 0 – 10v / 4-20mA analogue output and alarm relay contacts • TSI Nurses Station Monitor can display status of up to 8 rooms on 1 screen Monitors – Single room ■■RPM10 • PresSura Standard Room Pressure Monitor with Through-the-Wall Sensor ■■RPM10-PT • PresSura Standard Room Pressure Monitor for use with Pressure Transducer Sensor (not incl.) Monitors – Multiple rooms (Up to 3) ■■RMP20 • PresSura Premium Room Pressure Monitor with Through-the-Wall Sensor ■■RPM20-LON • PresSura Premium Room Pressure Monitor with LONworks Communications and Through-theWall Sensor ■■RPM20-PT • PresSura Premium Room Pressure Monitor for use with Pressure Transducer (not included) ■■RPM20-PT-LON • PresSura Premium Room Pressure Monitor with LONworks Communications for use with Pressure Transducer (not included) Nurses Station Monitor Controllers ■■RPC30 • PresSura Premium Room Pressure Controller with Through-The-Wall Sensor ■■RPC30-LON • PresSura Premium Room Pressure Controller with LONworks Communications and Through-theWall Sensor ■■RPC30-PT • PresSura Premium Room Pressure Controller for use with Pressure Transducer (not included) ■■RPC30-PT-LON • PresSura Premium Room Pressure Controller with LONworks Communications. For use with Pressure Transducer (not included) Pressure Transducers ■■TSI 801916 - PRESSURE TRANSDUCER +- 0.1 IN H2O (+/- 24.9PA) ■■TSI 801917 - PRESSURE TRANSDUCER +- 0.25 IN H2O (+/- 62.3 PA) Nurses Station Monitor ■■NSD8 – NURSES STATION MONITOR Other options available include keyswitches, door switch and remote visual alarms. 22 KENELEC.COM.AU / 1300 73 22 33 HOSPITALS & LABS FUME HOOD MONITORS FMH10 FUME HOOD MONITOR Fume hoods are a primary source or protection in laboratories. Face velocity measurements are often used to gauge the performance of a fume hood’s ability to contain and exhaust hazardous chemicals. By accurately measuring face velocity and alarming on unsafe conditions, TSI’s FHM10 Fume Hood Monitors provide a high level of fume hood safety. The FHM10 helps users comply with standards and regulations set forth by OSHA, NFPA, ANSI Z9.5, and SEFA, calling for monitors to be installed on fume hoods. Check your hood flow and filter efficiency using a TSI 5725 General Features Options • Accurately measures average fume hood face velocity • Temperature compensated sensor for accurate measurement as temperatures change in laboratories • Visual, audible and remote alarms warn users of unsafe conditions • Analog output provides additional information • Assists in managing risk by communicating fume hood status information to Building Management System (BMS) • Seamless integration via Modbus. BACnet and LonWorks options available • Easy installation and calibration • Easy configuration using keypad • Large display provides detailed fume hood information • Surface or flush mount options available • Optional Flow Monitor available ■■FHM10-01 • Fume Hood Monitor with Velocity Sensor ■■FHM10-02 • Fume Hood Flow Monitor (using existing flow station or venturi valve) TSI 5725 General Features NATA CALIBRATION IS AVAILABLE KENELEC.COM.AU / 1300 73 22 33 • 0.25 to 30m/s air velocity range • 0 to 60°C temperature range • Volumetric air flows, sweep mode, 100mm head • Air cone flow hood compatible • 12,700 point data logging, software & USB • Includes calibration certificate & 2 year warranty • NATA calibration is available 23 HOSPITALS & LABS FUME HOOD CONTROLLERS FMC50 FUME HOOD CONTROLLER TSI 800920 Slimline Module Sash Position Sensor FHC50 with Sidewall sensor (with FHC50-01) The Model FHC50 Fume Hood Controller adds the ability to control airflow to maintain safety and energy efficiency. There are two main monitor and control strategies that can be used with the Model FHC50 Fume Hood Controller: Face Velocity One of the key components of air flow in a fume hood is adequate face velocity, which is needed to protect fume hood users. An adequate face velocity will help contain contaminants inside of the fume hood. A fume hood exhaust system produces a negative pressure differential between the fume hood’s interior and the laboratory, causing air to be drawn into the hood. The speed of air entering the fume hood is called the face velocity. The Model FHC50 Fume Hood Controller can be configured to continuously monitor fume hood face velocity by measuring the air velocity across a sensor mounted in the sidewall of the hood. The sensor and opening in the fume hood are driven by the same pressure differential so the velocity across each is related. As an alternative to this sidewall sensing methodology, the Model FHC50 can determine average fume hood face velocity by measuring the fume hood exhaust flow and sash area. When measuring face velocity in this fashion, the Model FHC50 must use a venturi valve with feedback to control and measure the exhaust volume. A sash sensor then measures the vertical opening of the fume hood sash. As an option, the Model FHC50 can use a sidewall sensor to monitor or trim the face velocity when calculated from sash position and exhaust flow rate. The Model FHC50 controller modulates the exhaust to maintain an adequate face velocity at all FHC. Exhaust Flow Certain devices such as laminar flow benches, canopy hoods and snorkels need to exhaust a certain amount of air to function properly. For these applications, the Model FHC50 can be configured to measure and control the air flow to a constant volume using a venturi valve or a flow station with damper. 24 General Features • Controls fume hood face velocity to provide containment and safety • Reduces laboratory air flow usage, optimizing energy savings • Assists in managing risk by communicating fume hood status information to Building Management System (BMS) • Visual, audible and remote alarms warn users of unsafe conditions • Seamless integration via Modbus. BACnet and LonWorks options available • Easy installation and wiring • Fast-acting actuator provides containment during sash movements • Easy configuration using keypad or configuration software • Large display provides detailed fume hood information • Surface or flush mount options available Options: ■■FHC50-01 • Fume Hood Controller – Closed loop control of face velocity using thermal anemometry (sidewall sensor) ■■FHC50-02 • Fume Hood Controller – Open loop control of face velocity using sash position sensor ■■FCH50-03 • Fume Hood Controller – Combines open loop control using sash position sensor and closed loop control using sidewall velocity sensor to optimize speed of response ■■TSI 800920 • Slimline Interface Module for FHC50 and FHM10 KENELEC.COM.AU / 1300 73 22 33 HOSPITALS & LABS VENTILATOR TEST SYSTEMS TSI 4070 CERTIFIER FA VENTILATOR TEST SYSTEM The Certifier® FA Ventilator Test System 4070 is capable of testing multiple parameters of ventilator performance. It is designed to measure air, oxygen, and nitrous oxide flow and pressure in institutional, home care, field service, laboratory, and production applications. The Certifier FA ventilator test system is a battery-operated flow analyzer that can also test a variety of other medical equipment such as anesthesia gas delivery machines and oxygen concentrators. Their compact size makes these ventilator testers ideal for use in field service, biomedical shops, and manufacturing. General Features • Gas calibrations for air, O2, air/O2 mixtures and N2O • Uni-directional flow • Temperature and pressure compensated • Max breath rate 120 BPM • STP, ATP & BTBS flow & volume modes • LCD Display • Barometric pressure 500 to 2000 mbar • Low pressure -25 to 150 cm H20 gauge • Oxygen concentration (with optional 4073 Kit) Options ■■TSI 4073 OXYGEN SENSOR KIT ■■TSI 4072 LOW-FLOW MODULE TSI 4080 CERTIFIER FA PLUS VENTILATOR TEST SYSTEM Certifier® FA Plus Ventilator Test System 4080 is the full-feature system capable of testing virtually all models of ventilators: adult, pediatric, anesthesia, neonatal and high-frequency. It can also test a variety of other medical equipment such as anesthesia gas delivery machines, insufflators and oxygen concentrators. Its compact size makes this ventilator tester ideal for use in field service, biomedical shops, and manufacturing. General Features • Gas Calibrations for Air, O2, Air/O2 mixtures, N2, CO2 and N2O • Bi-Directional Flow • Temperature and pressure compensated • Max Breath Rate 1500 BPM • STP, ATP, BTPS, BTPD and user-defined flow & volume modes • Colour Graphic touch screen • Barometric Pressure 500 to 1700 mbar • Low pressure -25 to 150 cm H20 differential. • High pressure -10 to 150 PSI • Oxygen Concentration (with optional 4073 Kit) • USB interface for PC and printing Options ■■TSI 4073 OXYGEN SENSOR KIT ■■TSI 4082 LOW-FLOW MODULE ■■TSI 1303860 USB CABLE MINI A TO STD B KENELEC.COM.AU / 1300 73 22 33 25 HOSPITALS & LABS MASS FLOW METERS The TSI Mass Flowmeters can be used for a multitude of gas flow measurement applications. Whether measuring gas flows in a laboratory or manufacturing setting, TSI general purpose mass flowmeters provide accurate results with multiple data output options. The display versions come complete with accessories making setup and operation fast and convenient. The TSI mass flowmeters are specified as two percent of flow rate reading. One TSI mass flow meter covers the same range as three percent (or more) of full scale devices, with better accuracy at most points. Fast four millisecond response ensures accuracy in fluctuating flows. This fast response time of the TSI mass flowmeter is ideal for closed-loop control systems and integrated volume measurements. Low pressure drop of the TSI mass flowmeter minimizes flow circuit back pressure and its impact on the system. TSI LOW FLOW - 4140 SERIES General Features • TSI 4140 Low Flow series (0.01 – 20 std L/Min) • TSI 4040 High Flow series (0 – 200 & 0 – 300 std L/Min) • 4 millisecond flow response • High accuracy ±2% of reading • High turndown ratio • Low pressure drop • Versions available with or without display • Convenient 0 – 10V DC analog output of flow rate • Versatile RS232 digital output of flow rate, volume, pressure, temperature • Built-in temperature and pressure compensation • NIST-traceable calibration certificate included at no additional cost TSI HIGH FLOW - 4040 SERIES Low Flow – 4140 Series High Flow – 4040 Series Model 4140 41403 4143 41433 4040 Gas Calibration Air, O2, N2 Air, O2, N2, N2O Air, O2, N2 Air, O2, N2, N2O Air, O2, N2, Air/O2 Mixture Inlet/Outlet Diameter 0.25” (6.4 mm) Flow Measurement 0.375” (9.53 mm) 4043 4045 22 mm ISO tapered 0.50” (12.7 mm) 0.75” (19.1 mm) 0-200 Std L/min 0-300 Std L/min Range 0.01-20 Std L/min 0-300 Std L/min Accuracy — Air and O2 ±2% of reading or 0.005 Std L/min, whichever is greater ±2% of reading or 0.05 Std L/min, whichever is greater Accuracy — N2 ±3% of reading or 0.010 Std L/min, whichever is greater ±3% of reading or 0.1 Std L/min, whichever is greater Accuracy — Air and O2 mixture N/A ±3% of reading or 0.1 Std L/min, whichever is greater Accuracy — N2O N/A Response 4 ms to 63% of full scale flow 4 ms to 63% of full scale flow L/min, Std L/min, cm3/min, Std cm3/min L/min, Std L/min Overall Dimensions 5” x 2” x 1.25” (127 mm x 49 mm x 32 mm) 7.2” x 2.5” x 2.1” (182 x 63 x 53 mm) Volume* Range 0.01 – 99.9 liters 0.01 – 99.9 liters Measurement Accuracy ±2% of reading (see Operator’s Manual for additional details) ±2% of reading (see Operator’s Manual for additional details) Pressure Range 50-199 kPa absolute 50-199 kPa absolute Measurement Accuracy ±1 kPa ±1 kPa Response <4 ms to 63% of final value for step charge <4 ms to 63% of final value for step charge Temperature Range 0-50°C 0-50°C Measurement Accuracy ±1°C at flow greater than 1 Std L/min ±1°C at flow greater than 1 Std L/min Response <75 ms to 63% of final value for step change <75 ms to 63% of final value for step change Analog 0-10 VDC flow only, zero and span adjustable via RS232 0-10 VDC flow only, zero and span adjustable via RS232 Digital RS232 RS232 7.5 VDC ±1.5 V, 300 mA max 7.5 VDC ±1.5 V, 300 mA max LCD Display Units Outputs DC Power Input 26 ±3% of reading or 0.010 Std L/ min, whichever is greater N/A ±3% of reading or 0.010 Std L/ min, whichever is greater N/A KENELEC.COM.AU / 1300 73 22 33 HOSPITALS & LABS TSI LOW FLOW - 4120 SERIES - NO DISPLAY TSI HIGH FLOW - 4020 SERIES - NO DISPLAY Low Flow – 4120 Series Model 4121 Series Gas Calibration High Flow – 4020 Series 4122 Series 4021 Series 4024 Series 4121 41212 41216 41221 41222 41226 40211 40212 40241 40242 40246 Air 02 N2 Air O2 N2 Air O2 Air O2 N2 Inlet/Outlet Diameter 0.25” (6.4 mm) Flow Measurement Range 0.01-20 Std L/min 0-300 Std L/min Accuracy — Air and O2 ±2% of reading or 0.005 Std L/min, whichever is greater ±2% of reading or 0.05 Std L/min, whichever is greater Accuracy — N2 ±3% of reading or 0.010 Std L/min, whichever is greater ±3% of reading or 0.1 Std L/min, whichever is greater Response 4 ms to 63% of full scale flow 4 ms to 63% of full scale flow 5” x 2” x 1.1” (127 mm x 49 mm x 29 mm) 7.2” x 2.5” x 1.5” (182 x 63 x 38 mm) Pressure Measurement N/A N/A Temperature Measurement Range 0-50°C 0-50°C Accuracy ±1°C at flow greater than 1 Std L/min ±1°C at flow greater than 1 Std L/min Response <75 ms to 63% of final value for step change <75 ms to 63% of final value for step change Analog 0-4 VDC flow only, zero and span adjustable via RS232 0-4 VDC flow only, zero and span adjustable via RS232 Digital RS232 RS232 DC Power Input (User Supplied) 5.0 VDC ±0.25 V, 300 mA max 5.0 VDC ±0.25 V, 300 mA max Recommended Filtration HEPA-grade HEPA-grade Overall Dimensions Outputs 0.375” (9.53 mm) 22 mm ISO tapered 0.75” (19.1 mm) PRIMARY CALIBRATORS TSI offers two Primary Calibrator Models for calibrating pumps and any other air sampling instruments that draw an active air sample. These small, portable, battery-operated units are lightweight and easy to use. Volumetric flow rate is displayed continuously, making real-time pump adjustment, calibration and periodic flow checks fast and easy. These Primary Calibrators are temperature-compensated and pressure-corrected to calculate volumetric flow rate at an accuracy within 2% of reading. TSI 4146 PRIMARY CALIBRATOR KIT RANGE – 2.5 TO 300 LPM TSI 4046 PRIMARY CALIBRATOR KIT RANGE – 0.01 TO 20 LPM General Features: • Provides continuous real-time volumetric flow rate readings, so pump adjustment and calibration is fast and easy • Battery powered, compact and lightweight • Field portable—use the same primary calibrator for adjustment, calibration and periodic checks • Comes with a NIST traceable calibration certificate • Kits come complete and are ready to use • Model 4146 flow measurement range of 0.01 to 20 lpm • Model 4140 flow measurement range 2.5 to 300 lpm • Each Primary Calibrator Model Includes: Flowmeter, soft carrying case, battery pack, (6) AA Alkaline batteries, connectors, tubing, dampening chamber module (4146 only), battery pack lugs, 2-year warranty, user guide and NIST certificate of calibration KENELEC.COM.AU / 1300 73 22 33 27 SOUND & VIBRATION DIFFERENCE BETWEEN LMAX, LMIN AND PEAK When measuring noise levels Lmax and Peak should not be confused. Lmax is the RMS (root mean squared) maximum level of a noise source or environment where peak is the maximum level of the raw noise source. RMS values give a clearer understanding of a noise level, making calculations and measurements easier for a noise source waveform which is changing constantly in its magnitude. Jet Taking Off (25 mtrs away) • Lmax is the highest RMS sound pressure level within the measuring period • Lmin is the lowest RMS sound pressure level within the measuring period • Peak is the crest of the sound pressure within the measuring period (This is not a RMS level) 120 Gunshot Sound Pressure 110 1 minute Pneumatic Hammer Noisy Disco Peak Chainsaw RMS 100 Angle Grinder 97 15 minutes 30 minutes Personal Stereo (Max Volume) 94 1 hour 91 88 85 2 hours 4 hours 8 hours 75 Below this level hearing damage is negligable Ride-on Mower 90 Time Busy Road Power Mower Vacuum Cleaner Sound Pressure Graph Conversation Washing Machine Library Leaves Rustling Sound Studio Threshold of Normal Hearing 80 70 60 50 40 30 20 10 0 The above noise levels are approximate and should only be taken as a guide Noise Level in Decibels SOUND LEVEL METERS SL-805 SOUND LEVEL METER The SL-805 Digital Sound Level Meter is designed to meet the measuring requirement of noise abatement project, sound quality control, health, safety engineering at workshops, schools, hospitals, hotels, shopping centres, theatres, recording studios, offices, traffic, homes etc. General Features • Designed according to the IEC651 type 2 & ANSI S1.4 type 2 for sound meter • Sound Pressure Level measuring function (SPL) • 2 measuring ranges: Lo (low) : 35 - 100dB / Hi (high) : 65 - 130dB • 2 equivalent weighted sound pressure levels A and C • 2 dynamic characteristic modes : S (slow) and F ( fast) • Recording of MAX measuring value • Data-hold function • Low power indication 28 KENELEC.COM.AU / 1300 73 22 33 SOUND & VIBRATION NOISE AT WORK MEASUREMENT CASTLE SONUS GA116B AND GA216B POCKET SOUND METERS The entry level of the Castle Pocket Range of Sound Level Meters is the SONUS B (GA116B & GA216B), a feature packed, pocket instrument that is fully compliant with IEC 61672-1:2002. This meter gives simultaneous sound pressure (Lp) and peak (Cpeak) measurement for a multitude of tasks including Fire Alarm Testing and initial spot-check assessments to the Noise at Work Regulations 1989. It has a high-specification measurement microphone and is cased in tough, crack resistant ABS plastic. Designed for Engineers, Industrial Safety Officers and anyone with a need for competent sound measurements. This meter can assist with compliance to the Health and Safety at Work Act; Noise at Work regulation 1989. The Castle GA116B is a great general purpose sound level meter that will fit in your pocket and be ready whenever you need it. General Features • Applicable Standard - IEC 61672-1:2002 (Integrating, Sound Exposure and Sound Level Meters) • Sound Pressure (Lp) to 0.1 dB resolution • ‘A’ and ‘C’ frequency weighting (toggle) • ‘Slow’ and ‘Fast’ Time weighting (toggle) • Simultaneous measurement of Lp, Lmax, and Cpeak • Lmax - maximum Lp hold (rms.) • Cpeak - maximum peak level • Elapsed time (running time hrs, min, sec) • Overload and Under-range indication • Battery condition (Life approx. 12 hours) CASTLE SONUS GA257B PERSONAL NOISE EXPOSURE METER (DOSEMETER) CASTLE SONUS GA257L PERSONAL DATALOGGING NOISE EXPOSURE METER (DOSEMETER) The Castle SONUS GA257B is a dedicated basic dosemeter and a feature packed, pocket instrument that is fully compliant with IEC 61252:1993. This meter gives simultaneous sound exposure (LEpd) and maximum peak (Zpeak) measurements, an essential feature for assessments to the Noise at Work Regulations 1989. It has a high-specification measurement microphone and is cased in tough, crack resistant ABS plastic. Designed to be worn by an employee for a full- or part-shift, the GA257B has an ‘unbreakable’ pocket clip and a lockable keypad. The results are given in a simple, clear format to give an immediate indication of an employee’s daily exposure. Powerful, yet small and lightweight, the Castle GA257L noise dose meter combines the latest technological advances with a realistic price tag. With it’s clear and easy to read 8 character alpha numeric display, soft-touch keypad, electronic security lock and instant calibration facility, the GA257L is sure to prove invaluable in a wide range of occupational health applications. Designed for Industrial Safety Officers and Safety Managers for compliance with the Health and Safety as Work Act; Noise at Work regulation 1989. The Castle GA257B provides all the necessary information you need for completing Noise at Work risk assessments. General Features General Features • Applicable Standard - IEC 61252-1:1993 (Personal Sound Exposure Meters) • Integrated Sound Exposure Level (LEpd) • Projected LEpd (8 hour sound exposure) • DOSE% and Projected DOSE% (8 hours) • ‘A’ frequency weighting • Zpeak - maximum peak level • Simultaneous measurement of LEpd, and Zpeak • Elapsed time (running time hrs, min, sec) • Pa2hr (LEpd expressed in Pascals) • Overload indication • Battery condition (Life approx. 12 hours) All measured values can be saved to the internal flash memory of the GA257L for subsequent output. The results can be viewed on the instruments own display or downloaded to a PC using the included software. • Applicable Standards - IEC61672-1-2002 (Sound Level Meters) & IEC61252-1993 (Personal Sound Exposure Meters) • Measures Lep, Dose%, Dose per Hour and Pa2H • Measures simultaneously LAeq and either LZeq or LCeq • User selectable Exchange rate and Criterion level • C or Z weighted peak • Save results to internal flash memory • Download data to a PC via a USB connection • Analysis software included with the meter • Small and light weight, fits into small shirt or jacket pocket • Lockable keypad • Constructed of tough crack resistance plastic • Single battery operation of approximately 12 hours • Supplied with a strong clip for attaching to a belt or shirt pocket Options ■■GA216B SONUS • Digital Sound Pressure Level Meter Class 2 ■■GA116B SONUS • Digital Sound Pressure Level Meter Class 1 CASTLE SONUS NK004B SINGLE LOGGING DOSEMETER KIT CASTLE SONUS NK004 5 LOGGING DOSEMETER KIT Utilises the powerful Castle GA257L Data-logging Dosemeter. Utilises the powerful Castle GA257L Data-logging Dosemeter. General Features General Features Includes the following components: Includes the following components: • 1 x GA257L Data-logging Dosemeter • 1 x GA601 Calibrator – Single level, Class 2 • 1 x PC007 dBdataPRO Noise Analysis Software & Cable • 1 x KA010C2 Small Attache Kit Case Class 2 (Sonus) • 5 x GA257L Data-logging Dosemeter • 1 x GA601 Calibrator – Single level, Class 2 • 1 x PC007 dBdataPRO Noise Analysis Software & Cable • 1 x KA007 Dosemeter Kit Case (Accommodates 5 Dosemeters) KENELEC.COM.AU / 1300 73 22 33 29 SOUND & VIBRATION ENVIRONMENTAL SOUND MEASUREMENT CASTLE SONUS NK007B SONUS LOW NOISE WEATHERPROOF CASTLE GA116E SONUS DEDICATED ENVIRONMENTAL DATA-LOGGING SOUND METER CLASS 1 The environmental model of the Pocket Sonus Meter range is the class one Sonus GA116E. This instrument boasts an impressive noise floor reading allowing for the measurement and recording of low level ambient noise. The instrument is a full data logging and integrating sound level meter with a total linear measurement span of 108dB. Never before has such a credible and high performing environmental sound level meter been available at such affordable prices. The meter measures 3 percentiles one of which is user selectable plus the meter features dual measurement, so two versions of most parameters can be measured simultaneously. General Features • Applicable Standards - IEC 61672-1 : 2002 Class 1 Group X • Measures Lp, Leq, Lmax, LE, L10, L90, L(user) • Measures parameters simultaneously including LAeq and either LZeq or LCeq • Under range and Overload indicators • A, C or Z frequency weighting selection • A, C or Z Peak measurements • ‘Slow’, ‘Fast’ and ‘Impulse’ time weighting selection • Save results to internal flash memory • Download data to a PC via a USB connection • Noise Analysis Software included with the meter • Small and light weight, fits into small shirt or jacket pocket and also supplied with a strong pocket clip. • Lockable Key pad through options • Single battery operation of typically 12 hours • Weatherproof kit option Utilises the powerful Castle GA116E Environmental Data-logging meter. General Features Includes the following components: • 1 x GA116E Dedicated Environmental Data Logging Sound Meter • 1 x GA607 Dual Level Acoustic Calibrator • 1 x GA690 Barometer • 1 x KA020 Weatherproof Case for SONUS sound meters • 1 x ZL2094-03 3m weatherproof cable for KA020 and SONUS sound meters • 1 x MW402 Weatherproof Microphone Housing for SONUS range • 1 x PC007 dBdataPro Noise Analysis Software COMBINED SAFETY / ENVIRONMENTAL SOUND MEASUREMENT CASTLE SONUS GA116L SOUND LEVEL & NOISE EXPOSURE METER & SONUS GA216L SOUND LEVEL METER The flagship model of the Pocket Sonus Meter range is the class one Sonus GA116L which is a full data logging, integrating sound and noise exposure meter (dose meter) which has been designed for both Noise at Work assessments and Environmental Sound monitoring. Simply unplug the sound meter pre-amplifier and plug in the dose meter cable which is available as an optional accessory to convert to a fully functional dose meter. Setup couldn’t be easier, simply select Noise at Work or Environmental from the available user modes to automatically have the correct parameters selected then press the Record key to start logging. Available as a Class 1 instrument – GA116L and Class 2 Instrument – GA216L General Features • Applicable Standards – GA116L IEC 61672-1 : 2002 & IEC 61252 : 1993 • Applicable Standards – GA216L IEC 61672-1 • Measures Lp, Leq, Lmax, LE, Pa2h, Lep’d, Dose, Dose Per Hour, L10, L90, L(user) • Measures parameters simultaneously including LAeq and either LZeq or LCeq • Under range and Overload indicators • Hearing Protection using the HML method • User selectable Exchange rate, Threshold and Criterion level. • User Modes: Noise at Work, Environmental or ALL • A, C or Z frequency weighting selection • A, C or Z Peak Measurements • ‘Slow’, ‘Fast’ and ‘Impulse’ time weighting selection • Save results to internal flash memory • Download data to a PC via a USB connection • Noise Analysis Software included with the meter • Small and light weight, fits into small shirt or jacket pocket and also supplied with a strong pocket clip. • Lockable Key pad through options • Single battery operation of typically 12 hours Options ■■GA216L • SONUS Safety/Environmental Data-logging Sound Meter Class 2 ■■GA116L • SONUS Safety/Environmental Data-logging Sound Meter Class 1 30 KENELEC.COM.AU / 1300 73 22 33 SOUND & VIBRATION CASTLE NK001A CLASS 1 & NK001B CLASS 2 DATA LOGGING SAFETY / ENVIRONMENTAL SOUND KITS The Sonus L model features parameters for measuring a wide range of applications. The Safety and Environmental Data Logging Sound System is designed for Noise at Work and Environmental measurements and features the Sonus Logging meter. Select Noise at Work measurements for logging noise levels in the workplace, or switch the removable microphone for the dosemeter cable microphone (available separately) and measure personal noise and dose levels. Environmental parameters include L10 and L90 measurements and a third selectable percentile level. The kit is available in 2 options, with GA116L Class 1 meter or GA216L Class 2 meter CASTLE GA6224 CLASS 1 SOUND LEVEL METER FOR NOISE AT WORK MEASUREMENTS & ENVIRONMENTAL MONITORING Options ■■NK001A • Class 1 Data-Logging Safety/Environmental Sound System • Kit includes: • Class 1 GA116L - Safety/Environmental Datalogging Sound Meter • GA607 Calibrator, Dual Level, Class 1 (includes GA690 Barometer) • KA010 Small Attache Kit Case • PC007 dBdataPRO Noise Analysis Software and Cable ■■NK001B • Class 2 Data-Logging Safety/Environmental Sound System • Kit includes: • Class 2 GA216L Safety/Environmental Datalogging Sound Meter • GA601 Calibrator - Single Level, Class 2 • KA010 Small Attaché Kit Case • PC007 dBdataPRO Noise Analysis Software & Cable CASTLE GA6226 CLASS 2 SOUND LEVEL METER FOR NOISE AT WORK MEASUREMENTS & ENVIRONMENTAL MONITORING Measuring noise really does not have to be complicated, even for the novice, and the Castle 6224 (Class 1) Integrating sound level meter is designed with this in mind. The meter is ideally equipped for carrying out Noise at Work Risk Assessments, as well as the majority of environmental survey work. The range of parameters measured, the wide measuring capability of the meter and the ease of use, mean that this equipment is suitable for anything from aircraft noise to lawnmower design, and from construction sites to laboratories. General Features • Conforms with IEC 61672-1:2002, Class 1, IEC 60651:1979 and IEC 60804:2000 Type 1 • Measures Lp, LMH, Leq, LAe, Lmax, Lmin, Lx (L5, L10, L50, L90, L95), Peak. • Six ranges: 20 – 80dB, 20 – 90dB, 20 – 100dB, 20 – 110dB, 30 – 120dB, 40 – 130dB • Frequency weighting A, C, FLAT • Time weighting FAST, SLOW, IMPULSE • 5 user selectable percentile values (Ln) • Wide linearity range of 90dB • RS232 for data output to optional software • Memory storage for 10,000 data-points • Back-lit LCD display Class 2 Sound Level Meter – similar to the GA6224. The Castle 6226 provides the essential measurements required by the Control of Noise at Work Regulations 2006, including Leq (equivalent continuous level) in ‘A’ and ‘C’ weightings, and Cpeak. The meter can data-log any of these parameters in up to 10,000 data-memories, making it more than powerful enough for the task in hand. Also ideally suited to environmental monitoring, the Castle 6226 can measure 5 selectable percentile values and sound exposure (LE). Most environmental measurements require Leq and L90 plus possibly one or two other measurements. These can all be measured simultaneously with the Castle 6226 and data-logged into its 10,000 datapoint memory. General Features • Conforms with IEC 61672-1:2002, Class 2, IEC 60651:1979 and IEC 60804:2000 Type 2 • Measures Lp, LMH, Leq, LAe, Lmax, Lmin, Lx (L5, L10, L50, L90, L95), Peak. • Six ranges: 20 – 80dB, 20 – 90dB, 20 – 100dB, 20 – 110dB, 30 – 120dB, 40 – 130dB • Frequency weighting A, C, FLAT • Time weighting FAST, SLOW • 5 user selectable percentile values (Ln) • Wide Linearity range of 100dB • RS232 for data output to optional software • Memory storage for 10,000 data-points • Back-lit LCD display CASTLE NK002C CLASS 1 & NK002D CLASS 2 RISK ASSESSMENT / ENVIRONMENTAL KITS The meter is ideally equipped for carrying out Noise at Work Risk Assessments, as well as the majority of environmental survey work. The range of parameters measured, the wide measuring capability of the meter and the ease of use, mean that this equipment is suitable for anything from aircraft noise to lawnmower design, and from construction sites to laboratories. The Castle GA6224 and GA6226 provide the essential measurements required by the Control of Noise at Work Regulations 2006, including Leq (equivalent continuous level) in A and C weightings, and Cpeak. The meter can data-log any of these parameters in up to 10,000 data-memories, making it more than powerful enough for the task in hand. KENELEC.COM.AU / 1300 73 22 33 General Features Kit Contains: • GA6224 - Class 1 Industrial/ Environmental Logging SLM or GA6226 - Class 2 Industrial/ Environmental Logging SLM • GA601 or GA607 - Acoustic Calibrator • PC0226-4 - Data Management Software and Interface Cable for use with GA6224/GA6226 • Carry case Options ■■NK002C • Class 1 Risk Assessment / Environmental System ■■NK002D • Class 2 Risk Assessment / Environmental System 31 SOUND & VIBRATION NOISE RECORDING - NOISELOG CASTLE NOISELOG – NOISE RECORDER SYSTEM Recording neighbourhood nuisance noise has always been a costly, time-consuming affair with tape storage, calibration difficulties and analysis problems afterwards. The Castle NoiseLog solves all of these problems providing a cost effective solution allowing noise complainants to record offending noises for measurement and identification, thus assisting with fast and effective dispute resolution. Following a simple set-up, the complainant is left with a single button switch to start and stop recordings instantly. The use of SD cards means recording time is only limited by the size of the card. Each NoiseLog kit is supplied with: • GA507 Noise Log Sound Recording System including mains power unit, handset, microphone, preamplifier and cable with table-top tripod and mounting adaptor • GA607 Dual Level Calibrator (94dB/104dB) • Noise Log PC Software General Features • Class 1 and Class 2 versions meet the same frequency response and dynamic range requirements as sound level meters complying with IEC 60651 or IEC 61672 • Available in 3 versions – Class 1, Class 2 and budget • CD quality recording onto SD memory card • Simple one-push handset to start and stop recording • Recording time only limited by size of SD card memory fitted. Supplied with 1GB card giving 3.25 hours recording at 44.1 kHz sampling rate. • All contained in one robust, lockable metal case. All cable connections and controls except handset not accessible once locked Options ■■NK030A CLASS 1 ■■NK030B CLASS 2 ■■NK030C BUDGET Noise Recorder Software NOISE ACTIVATED WARNING SYSTEMS CASTLE GA902 NOISE ACTIVATED WARNING SYSTEM According to industrial safety law, areas subject to hazardous noise must be clearly defined, and workers notifies of the danger. In many cases, the noise hazard is intermittent and that’s precisely the situation for which the GA902 was designed. The GA902 activates only when the noise exceeds a pre-set level allowing exposed workers to wear ear defenders - often a less than popular safety measure - only when absolutely necessary. General Features • Measuring Range 74dB to 112.5dB • Trigger level adjustable in 2.5dB steps • Housed in a rugged enclosure – stainless steel housing also available for food and pharmaceutical • ‘A’ Frequency weighting in accordance with IEC651 Type 2 • Supports additional remote beacon and a mini-beacon that attaches to underside of GA902 • Integrated microphone. Supports remote microphone option • Mains powered with ‘On’ indicator 32 CASTLE GA904 ELECTRONIC ORANGE (ENTERTAINMENT NOISE CONTROLLER) Everybody likes to party, but it’s all too easy to let music levels get out of hand and when the morning comes, complaints come rolling in and your licence is on the line. The Castle Electronic Orange Noise Controller will keep your premises free from the risk of complaints and closure. The unit is connected to the main power supply for the amplification equipment. The Electronic Orange flashes a warning when pre-set sound levels are exceeded. If the operator doesn’t turn down the sound within a pre-set time, an automatic cut off kicks in. The music never has to stop, because a warning light flashes if the limit is exceeded, and only when this is ignored does the power supply cut off to prevent further abuse. Pioneered by Castle, this unit, approved by The Environmental Health, is used by thousands of venues through the World, and the latest model is as easy to use, robust and reliable as ever. General Features • Easy to Install • Simple to Operate • Anti-tamper Protection • Trip range 75dB to 112.5dB in 2.5dB steps • Trip time 1 sec to 10 sec, user adjustable. • Modes - Manual: Tripped unit must be manually reset / Auto:Tripped unit automatically resets after trip time. • Frequency weighting - ‘A’ and ‘B’ in accordance with IEC651 Type 2 KENELEC.COM.AU / 1300 73 22 33 SOUND & VIBRATION CASTLE GA907 DBALERT PERSONAL NOISE WARNING UNIT dBAlert! is a personal noise monitor that activates only when the noise exceeds a pre-set level, warning exposed workers that noise levels have become dangerous and to put on their ear-defenders. Perhaps more importantly for the employee, this means that they will also know when they can legally take them off! Being of rugged construction, dBAlert is suitable for most industrial situations. It comes complete with a pocket clip and the membrane keypad means that integrity and simplicity of use are maintained. dBAlert! also includes a vibrating alert , which gives the wearer the added warning of a mobile phone style vibrating alert to bring attention to the fact that dangerous noise levels have been exceeded. General Features • Measuring range 80dB to 103dB • User-Selectable to 80dBA, 85dBA, 90dBA and 95dBA (factory set to 80dBA) • Frequency weighting - ‘A’ in accordance with IEC 61672-1:2002 Class 2 • WARNING LED 1 x Hyper-Bright, LED,pulsed through software control • VIBRATING ALERT Mobile phone style vibrating motor for tactile warning (approx 150Hz) • Weight 70g (with batteries) Options ■■QUANTITY 1 OFF ■■QUANTITY 5 OFF ■■QUANTITY 10 OFF KENELEC.COM.AU / 1300 73 22 33 GA908 SOUND CHECK PERSONAL NOISE INDICATOR Excessive noise in the workplace is common in many professions and is a potential risk for a large number of employees. It can lead to hearing loss which is a permanent work-related injury. It is not only in the workplace that noise can be a problem, music events, discos or other leisure activities where excessive noise is involved can be one of the greatest causes of hearing damage- especially for young people who are not aware of the dangers! The Sound Check allows you to assess at a glance, situations that may affect your hearing in and out of the work place. It contains a microphone sensor that registers noise levels in the wearer’s surroundings. A microchip translates this into light - in coloured LEDs as follows: GREEN = < 80 dB(A) YELLOW = 80-100 dB(A) RED = > 100 dB(A) General Features • Weight = 22g • Dimensions = 85mm x 55mm x 8mm • Accuracy = +/- 5dB • Battery life = max 100 hours. • Trip levels = Green < 80dB, Amber < 100dB and Red > 100dB. Options ■■QUANTITY 1 OFF ■■QUANTITY 5 OFF ■■QUANTITY 10 OFF 33 SOUND & VIBRATION VIBRATION INSTRUMENTS - CONDITION MONITORING CASTLE GA2006S CASTLE VEXO S SINGLE AXIS MACHINERY VIBRATION METER CASTLE GA2002 POCKET VIBRATION METER Simple to use Vibration Meter for measuring acceleration, velocity and displacement. Ideal for checking fixed monitoring systems, condition maintenance prediction and other engineering operations. Reliable, repeatable and simple are three important criteria most people have when looking at taking vibration measurements. The GA2002 offers this on a plate and at a price unbeatable for what you get. This Instrument will give you all the fundamental vibration measurements in many of their variations using single key strokes. This makes it perfect for general machine and bearing vibration monitoring as well as other general-purpose vibration measurements. When you purchase a GA2002 it comes as a complete working system. The following components are included: • GA2002 General Purpose Pocket Vibration Meter • KD1001 Basic Accelerometer • ZL1094-M12 Accelerometer Cable • KD1204 Magnetic Mount • KD1206 Small Spike Probe • KA013 Kit Case The Vexo S is dedicated to monitoring vibration from industrial sources such as rotating machinery, bearing housings and any other source of mechanical vibration. With dedicated alarm modes for machinery rating and bearing condition, the Vexo S is perfect ly suited to busy maintenance teams who need the right answers right now! The supplied re-chargeable battery pack and charger means you also won’t ever be fumbling around for fresh batteries when you are supposed to be on the shop floor making measurements! The GA2006S is supplied with the following components: • Vexo S Instrument, Accelerometer and 1m Cable • Rechargeable battery pack and recharger • Removable Spike Probe • Getting Started Laminated Sheet • Vibdata LITE software & USB Cable • Carry Case for GA2006S and Accessories General Features General Features • Small and light weight • Simple to Use • Highly Robust • Tactile Keypad • 8 Character LCD Display • Simple Data-logging of 9 Data-points • Comes complete with Accelerometer, Cable, Spike Probe and Case • Multiple Filters - Mechanical and Linear • Multiple Integration Modes - Acceleration, Velocity and Displacement • Multiple Measurements - RMS, Max RMS and Peak • Machinery condition monitoring to ISO 10816-1, 3 & 7 • Bearing condition indication • Trending analysis (with optional VibdataPro) • Environmental Vibration • Single Axis mode for simple setup • Large colour display • Large ‘Flash’ memory • Re-chargeable battery pack and charger • Only 3 operational buttons for simple use • Built tough with rugged accelerometer and cable CASTLE VK027 PRO-DX EXCIEO GENERAL PURPOSE VIBRATION SYSTEM This general purpose Excieo vibration meter system includes a rugged accelerometer and cable along with a spike probe, PC software and an attaché case. The GA2005 Vibration Meter boasts multiple frequency filters covering a wide range of applications. It has large data-logging capabilities with the option of recording time-histories, useful in Environmental measurements. This rugged instrument is also incredibly simple to use with good battery life and fast download to a PC via USB The following components are included in the VK027 Pro-DX Excieo General Purpose Vibration System: General Features • Advanced data-logging functions and simple file management • 1 second to 12 hours log time intervals • 12 Frequency Filters • KD1003 - Sensitivity: 100mV/g, Range (f.s.) ±80g • KD1003 - Frequency response 2-13000Hz +5% • Display Electro-Luminescent, Back-lit LCD panel (160x160 pixels) • Suitable for environmental monitoring, machine condition and bearing condition monitoring • GA2005S - Pro-DX Excieo Multi-purpose Vibration Meter (not HARM or WBV) • KD1003 - Standard Accelerometer (Amplified Output) • ZL1097-FLEX - Flexible coil cable for general purpose measurement • KD1205 - Large Spike Probe • KA016V - Kit case for Excieo • PC009 - VIBdataPRO 34 KENELEC.COM.AU / 1300 73 22 33 SOUND & VIBRATION VIBRATION INSTRUMENTS – HUMAN VIBRATION MEASUREMENT CASTLE GA2003 POCKET HARM (HAND ARM RISK MEASUREMENT) VIBRATION METER Damage to the Hand and Arm through exposure to vibrating hand held power tools is rapidly becoming a major area of health and safety risk assessment. Up to now, the process of gathering data to support such a program has been both difficult and costly. The GA2003 will provide the data you need to calculate daily exposure as recommended in the HSE guide HS(G)88, for an individual employee. This is exactly what has been missing from the equation where Hand Arm Vibration is concerned. The GA2003 is suitable for industrial vibration measurements, machine condition, building vibration and Hand Arm vibration indicative measurements. The following components are included with the GA2003: CASTLE GA2006H CASTLE VEXO HARM (HAND ARM RISK MEASUREMENT) VIBRATION METER & VK036 VEXO HARM VIBRATION SYSTEM Quick, reliable measurements are all-essential when it comes to the assessment of Hand Arm Vibration and the Vexo H has been specifically designed to make the job as simple as possible. The small size, combined with a powerful processor and large memory will enable Safety Professionals to take Hand Arm Vibration to the next level. VK036 kit includes the GA2006H plus VIBdataPro Vibration Analysis Software. VIBdataPro gives you quick access to all your data and allows you to analyse data and export for reporting. The following components are included with the GA2006H: • GA2003 HARM®/Gen. Purpose Pocket Vibration Meter. • KD1001 Basic Accelerometer • ZL1094-M12 Accelerometer cable • KD1207 General Purpose Mounting Block • KA013 Kit Case • Vexo H Instrument, Accelerometer with 1.4m Cable • Accelerometer Mounting Block and Screw • Rechargeable Battery Pack and Recharger • Getting Started Laminated Sheet • Vibdata LITE software & USB Cable • Carry Case for GA2006H and Accessories General Features The following components are included with the VK036: • Small and Light weight • Simple to Use • Highly Robust • Tactile Keypad • 8 Character LCD Display • Simple Data-logging of 9 Data-points • Comes complete with Accelerometer, Cable and HARM BLOK® • Multiple Filters (Mechanical and HARM®) • Multiple Parameters (Acceleration, Velocity and HARM®) • Multiple Measurements (Lav, rms, Max.rms. and Peak & Elapsed Time) • GA2006H components as listed above. • PC009 VIBdataPro Vibration Analysis Software General Features • For compliance with: ISO 5349 : 2001 Measurement and evaluation of human exposure to handtransmitted vibration • Parameters Acceleration - Arms, Aeq, Amax, Peak, Vector Sum, Exposure Points • Full Colour Graphic OLED Display (160 x 128) • Frequency Weighing WH - Hand Arm Filter • Transducer Castle KD1010 Tri-Axial Accelerometer, 10 mV/g • Flash memory storing up to 992 recordings Options ■■CASTLE VEXO HARM VIBRATION METER ■■CASTLE VEXO HARM VIBRATION SYSTEM CASTLE EVEC SELF-CONTAINED WHOLE BODY VIBRATION METER Evec was designed to facilitate the measurement and evaluation of whole-body vibration. Evec offers advanced technology which can be learned easily and quickly, even by untrained users. The seat sensor, including its integrated memory, is just placed on the driver’s seat - without having to be mounted mechanically and without needing any disturbing cables. The sensor is activated and the measurement thus started with just a few operator steps. The necessary software is installed on a PDA or a notebook with Bluetooth interface. You need just a few settings – and your evec system is ready for use. The data recorded is also read from the seat sensor through Bluetooth. There are no annoying cables which might be damaged during the measurement. The driver does not have to do anything. The evec system automatically registers when the driver gets up and, complying with EN 14253, cuts off the peaks when the driver sits down too energetically. This allows precise measurements of the load to which the driver is exposed through the effect of vibrations. Special data preparation is not necessary. Conforming to EU Directive 2002/44/ EC, the evec software calculates the A(8) value of the daily exposure, no matter whether the measurement covered the full span of eight hours or whether evaluation is based on a shorter time period. KENELEC.COM.AU / 1300 73 22 33 The following components are included with the EVEC whole-body vibration system: • Evec seat pad with integrated sensor • CD-ROM with software for PDA and notebook • Evec battery charger incl. batteries • Plastic case with magnetic on-off switch • Operating instructions in English • Optional: PDA or notebook with preinstalled software General Features • Meets standards ISO 2631, ISO 10326, ISO 8041, VDI 2057, EN 14253, ISO 10326 • Storage Capacity for a measurement of 36 hours • Wireless communication between sensor and PDA or Notebook • Evec seat pad according to ISO 10326 (in black) with integrated triaxial acceleration sensor • Microcontroller for evaluating acceleration signals according to ISO 2631 • Algorithm for identifying and eliminating undesired effects • Driver-seat contact sensor • Easy-to-operate • Short training period • Automatic identification and elimination of undesired effects • Automatic calculation of exposure time (ET) and daily exposure A(8) 35 OTHER PRODUCTS AND CATALOGUES ENVIRONMENTAL MONITORING CLEAN ROOM MONITORING Real Time Dust Monitoring Systems, Gravimetric Sampling, Dust Deposition Gauges, High Volume Samplers, Diesel Particulate Monitoring, Emission Testing, Microbial Air Sampling, Weather Stations, Rain Gauges, Tip Buckets, Wind Speed & Direction. Particle counters, EMS Systems, Microbial Samplers, Education, Training, Validation, Lab Testing, Ventilation Test Instruments & General Instruments Portable & Fixed Air Quality Monitors, Dust Monitors, Ventilation Testers, CO2, CO and Multi-Gas Monitors, Sample Pumps, Clean Room Monitors, Computer Room Testers, Microbial Samplers SOUND & VIBRATION PRODUCTS State-of-the-art, Latest Generation Systems and Instruments. Portable Sound Meters, Tripod Based Stations, Portable Vibration Meters, Fixed Sound & Vibration Products & Accessories WATER QUALITY MONITORING Water Particle Counters, Streaming Current Monitors, Water Quality Meters, Water Level Meters, Water Flow Meters, ORP, DO, Conductivity, pH, Turbidity, Salinity, Temperature, Ozone, Chlorine VENTILATION TEST EQUIPMENT Hotwire & Vane Anemometers, Air Balancing Hoods, Manometers, Indoor Air Quality Meters, Gas Leak Detectors, Data Loggers, Temperature & Humidity Meters WEATHER STATIONS Low Cost Wireless Weather Stations, Middle Range General Purpose Stations, High Performance Top End Stations, Rain Gauges, Weather Sensors, Data Loggers, Dust Monitors Nd:YAG Lasers, PIV Lasers, Laser Ablation Systems, Micro Machining Systems, Continuous Wave Lasers, Wafer Scribing Systems, Sample Cells & General Accessories SPEED & LENGTH MEASUREMENT The Latest Technology in Laser Speed & Length Measuring Systems for Metal & Industrial Applications. Non-Contact Speed and Length Measurement Gauges & General Accessories FILTER TESTING EQUIPMENT Portable Hand-Held Particle Counters, Air Velocity Meters, Manometers & Pressure Meters, Dedicated High End Filter & Respirator Testers & General Testing Instruments PARTICLE & AEROSOL RESEARCH Particle Counters & Sizers, Atomizers & Aerosol Generators, Water & Butanol Based CPCs, Aerosol Research Instruments, Aerosol Accessories, Ultra-fine & Nano Particle Instruments FLUID MECHANICS LDV Systems, PDPA Systems, PIV Systems, Global Spray & Imaging Systems, Hotwire Anemometer Systems, PIV Lasers, Mounts, Cameras, Probes & Accessories DATA LOGGERS & TELEMETRY Portable Low Cost Data Loggers, Middle & High End Loggers, Solar Panels, Telemetry Systems, SCADA System Integration, RF Transceivers, Satellite Telemetry, Batteries, Outdoor Enclosures VISA, MASTERCARD, AMEX Accepted Please note: the prices in this catalogue are provided as a guide only and are subject to change without notice. Please check at time of purchase. Delivery cost and GST are not included. (4% +GST surcharge on AMEX) Australia & NZ Head Office NSW Office 1300 73 22 33 23 Redland Drive Mitcham VIC 3132 Australia Building 5, 49 Frenchs Forest Rd Frenchs Forest NSW 2086 Australia Email - info@kenelec.com.au T +61 3 9873 1022 / F +61 3 9873 0200 T +61 2 8977 4017 / F +61 2 8977 4000 National Freecall No. www.kenelec.com.au 765 / OH&SCAT-NP / 14867 / APR15 INDOOR AIR QUALITY LASERS & LASER ABLATION