telecentric laserprojector
Transcription
telecentric laserprojector
STRUCTURED LIGHT AND LASER BEAM SHAPING SOLUTIONS TELECENTRIC LASER PROJECTOR Telecentric micron thin line projector for high precision 3D structured lighting inspection applications. FEATURES Constant thickness over entire line length Line thickness down to 5μm Collimated line length Line length up to 100mm Reduced image occlusion Uniform line intensity profile Telecentric Laser Projector (TLP) provides parallel non angular laser line illumination as opposed to conventional lasers lines that projects a diverging fan. The TLP has the advantage of reducing object occlusions on your image plane critical for 3D high precision structured lighting applications. In these applications the TLP evenly illuminates the complete part under inspection in order to achieve the measurement accuracy required. STANDARD LASER TELECENTRIC LASER Object occluded No occlusion INTENSITY DISTRIBUTION ON A FLAT SCREEN AT FOCAL POSITION INTENSITY DISTRIBUTION ON A FLAT SCREEN AT FOCAL POSITION -2 Line thickness Line thickness -2 0 2 4 0 2 -2 -1.5 -1 -0.5 0 0,5 1 1.5 2 4 -2 -1.5 -1 -0.5 0 0,5 Line length Line length Varying line thickness Constant line thickness 1 1.5 2 Another advantage of the TLP is that its thickness is constant over its entire length. In applications such as semiconductor inspection, it is very important to have micron thin line over the entire length. With conventional fan out laser lines it is not possible to have both a thin line over a wide field due to depth of focus limitations. With the TLP, its parallel non angular illumination design allows for constant micron thin lines over large field of views. MODULATION The Telecentric Laser Projector can be modulated by an external 0 to 5V external signal through the white wire. The S type modulation is included by default with the Telecentric Module. FUNCTION CODE ON OFF TTL Reverse TTL T RT 0 to 2V 3 to 5V 3 to 5V 0 to 2V 100% 80% 20% 0% 0 SPECIFICATIONS < 3 mrad ≈ 0.25 nm/ degC < 6 μrad/°C < 5μ sec, 100% modulation depth (10 Kohm input impedance) ESD, Over voltage (up to 30 VDC), Over-temp Shutoff (> 50 deg C) < 3 %, 2 minute warm up time 5 ± 0.5VDC, 4.5 to 30V Optional (9-30V for < 635 nm) -10 to to +50 °C (housing) < 1500 g 18 inches 3 conductors Belden 9533, with flying leads Level 4 30g, 6ms, functional MECHANICAL SPECIFICATIONS Example of 10, 55 and 100mm TLP Shown RS Optimal 40% Note: One modulation input needs to be selected, S (default), RS, T or RT Bore sight (mrad) Wavelength Drift Pointing Stability Modulation Rise/Fall time Protections (Built in) Long term Power stability (8 hours) Operating Voltage Working Temp Range Weight Power Supply Cable ESD Protection Shock Tolerance S 60% 2 4 TELECENTRIC SINGLE LINE GENERATOR FIG 1 - INTENSITY DISTRIBUTION ALONG THE LINE FIG 2 - LINE STRAIGHTNESS 1 1.5 1 0.8 0.5 0 Relative intensity 0.6 -0.5 0.4 -1 -1.5 -1.2 0.2 0 -1 -0.8 -0.6 -0.4 -0.2 Best linear fit -1 -0.8 -0.6 -0.4 -0.2 0 0.2 Normalized Fan angle 0.4 Fan angle defined at 80% intensity clip level 0.6 0.8 0 0.2 0.4 0.6 0.8 Max deviation ∆ 1 1.2 Line shape 1 Relative intensity distribution SPECIFICATIONS SPECIFICATIONS VALUES Uniformity Imax – Imin Imax +Imin (line intensity distribution along the line)1 Relative intensity clip that define the fan angle Contained energy Energy in fan angle In the fan angle total energy Line Straightness ∆ L (line lenght) (deviation from the best linear fit)1 20% (typical) ≤7.5% 80% ≥95% ≤0.1% ≤0.05% Uniformity and straightness are measured at 80% of the fan angle (100% for SL Plus). 1 ORDERING CODE TLP - XXX - Wavelength XXX - Diode Power X - Electronic 405, 450 1 S Up to 520, 635 to RS 100mm 660, 830nm 260mw X - XX - Line Length Line Tickness Down to XXX-XX - Working Distance XXXXX Option To specify SD 5μm 24V T RT Example: TLP - 405 - 125 - RT- 55 - 20 - 190 OSELA inc. 1869 32nd Avenue, Lachine, QC, H8T 3J1 Canada info@osela.com 514 631.2227 osela.com