AuRA XP™ Laser system specifications

Transcription

AuRA XP™ Laser system specifications
Aura XP™ Laser System Specifications
Laser Type
Laser Wavelength
Laser Power
StarPulse
Peak Power
Quasi-Continuous
Wave
532 nm
0.5 to 15 watts
NA
Cooling
Electrical
Requirements
Air cooled
Single Phase
• 100 VAC/20 Amps
• 120 VAC/15 Amps
• 230 VAC/10 Amps
Weight
Dimensions
60 lbs / 27 kg
16''H x 12'' W x 23''D
(42cm x 31cm x 58cm)
Exposure Duration
Exposure Intervals
Pulse Rates
0.1 to 1 sec in 0.1
increments, then .5
sec increments
to Continuous
Single or 0.1 to 1 sec
in 0.1 increments
NA
Aura XP™ (Starpulse™) Laser System Specifications
Laser Type
Laser Wavelength
Laser Power
StarPulse
Peak Power
Quasi-Continuous
with StarPulse
532 nm
0.5 to 15 watts
160W
Cooling
Air cooled
Electrical
Requirements
Single Phase
• 100 VAC/20 Amps
• 120 VAC/15 Amps
• 230 VAC/10 Amps
Weight
Dimensions
60 lbs / 27 kg
16''H x 12'' W x 23''D
(42cm x 31cm x 58cm)
Exposure Duration
Exposure Intervals
1 to 50 milliseconds Single or 0.1 to 1 sec
in 1msec increments, in 0.1 increments
then .1 to 1 sec in
0.1 increment, then
.5 sec increments to
Continuous
Pulse Rates
1 to 10 pulses
per second when
duration set between
1 to 50 milliseconds
gYn
uRo
eNt
The laser system should only be used in conditions where its use is appropriate and of proven efficacy. Clinical applications
should be under the direct supervision of a qualified surgeon. The use of the laser is contraindicated for patients: whose
general medical condition contraindicates surgical intervention; where appropriate anesthesia is contraindicated by
patient history; where tissue (especially tumors) has calcified; for hemostasis of vessels over approximately two millimeters
in diameter; where laser therapy is not considered the treatment of choice.
American Medical Systems, Inc.
World Headquarters
10700 Bren Road West
Minnetonka, MN 55343
USA
Phone: 952 930 6000
Fax: 952 930 6157
www.AmericanMedicalSystems.com
©2006 American Medical Systems, Inc. All rights reserved. Printed in USA.
153743_Aura Brochure.indd 1
­­
American
Medical Systems
Europe B.V.
Straatweg 66H
3621 BR Breukelen
THE NETHERLANDS
Phone: 31 346 258 100
Fax: 31 346 258 130
American Medical Systems
Australia Pty. Ltd.
Suite 2, Level 2
460 Church Street
North Parramatta 2150
NSW AUSTRALIA
Phone: 61 2 8838 8800
Fax: 61 2 9890 9899
American Medical Systems
Canada Inc.
P.O. Box 461
Guelph, Ontario
N1H6K9 CANADA
Phone: 519 826 5333
Fax: 519 821 1356
Order Number: 23000157A (08/07)
8/24/07 12:27:29 PM
Designed to match
Performance with Portability
Versatility. Portability. Affordability.
The Aura XP™ 15 Watt laser system delivers
massive performance, portability, and steady-state
reliability for a range of soft tissue applications in
the hospital, office or ambulatory surgery center.
Aura XP Versatility
Built to be moved quickly, easily and conveniently,
the Aura XP laser system offers a versatile platform
that enables continuous wave and pulsed
mode (StarPulse) operation applicable for
Urology, ENT, Gynecology and General Surgery
applications, expanding performance and
maximizing investment.
Multiple Applications
• Urology
• ENT
• Aesthetics
• Gynocology
• General Surgery
Designed for Function as well as for
Standard Electrical Utilities
Plug and play operation enables
easy movement from one room
to another and expedites
procedure time.
Form
Compact Design
The compact Aura XP easily fits
in the smallest of procedure
rooms and can operate from a
counter top or portable cart.
Broad Fiber Optic Line
A wide range of fiber optics
deliver efficient treatment
on numerous URO, ENT,
GYN, DERM and General
Surgery applications.
Solid-State Reliability
Reliable, solid-state construction
sets a new standard for high
performance with easy
care maintenance.
Precise Cutting and Coagulation
Star Pulse limits the depth of
penetration for increased control,
while providing excellent
hemostasis, vaporization, and
cutting power.
Bare EndoStat™ IQ™ fiber optic line
includes sizes 0.2, 0.3, 0.4 and 0.6 mm.
153743_Aura Brochure.indd 2
8/24/07 12:27:35 PM