cooling unit replacement
Transcription
cooling unit replacement
PLUS COOLING UNIT REPLACEMENT HARDWARE : FOR NUVO ONLY HOLE SIZE FOR COOLING UNIT Typically the replacement/upgrade unit will fit the existing opening. Please check! : If any alteration is needed, you will have to modify it. 15 5/8 ” min 15 3/4 ” min 9 3/8 ” min 9 1/2 ” min BACK OF CELLAR ABOVE DOORWAY & HOLE IN WALL PREPARING FOR NUVO INSTALLATION &22/,1*81,7,167$//$7,21 5XQOLJKWFRUGWKURXJK&XWRXW6OLGHXQLWLQWRWKHEDFNRSHQLQJE\DQJOLQJXQLW$WRDOORZOLJKWFRUGWRFOHDU DQGVWUDLJKWHQWRSXVKLQ%6FUHZDOOHQEROWVWKURXJKERWWRPÁDQJHKROHV0DNHVXUHXQLWLVOHYHO $ %$ 7239,(: )ODQJHEROWVLQFRROLQJ XQLWER[ &. 2) &( // $5 % 7239,(: 127(,IXQLWLVRSHUDWHGDFFRUGLQJWRVSHFLÀFDWLRQVRYHUÁRZVZLOOQRW RFFXU ([FHVV FRQGHQVDWLRQ LV RQO\ FDXVHG E\ H[WUHPH FRQGLWLRQV 8QLW ZLOO VKXW RII DW ) DQG ZLOO UHVWDUW ZKHQ WHPSHUDWXUH GURSV RU XQLW LV UHSOXJHG ,Q WKLV FDVH LQVHUW µ 2' KRVH WR GUDLQ KROH FXW WR DSSURSULDWHOHQJWK 2SWLRQDOQRWUHTXLUHG H[FHSWDVHPHUJHQF\ GUDLQ &RQWDLQHU &21752/63/8*,7,1ZDLWRQHPLQXWHDQG(1-2< )($785(6 'HIDXOW6(7WHPSHUDWXUH)&LGHDOIRUZLQHVWRUDJH ',63/$< &DOLEUDWLRQRSWLRQRIWKHWHPSHUDWXUHVHQVRU 'LVSOD\RIDFWXDOWHPSHUDWXUHE\UHTXHVW 6(7WHPSHUDWXUHUDQJH)) 'LJLWDOWHPSHUDWXUHVHQVRU 'XDOGLVSOD\)& 6HWWLQJVDUHVWRUHGLQPHPRU\IRUSRZHUIDLOXUHV 3UHSURJUDPHGVRIWZDUHZLOOUHDFKWKHTXLHWHVWPRVWHIÀ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ÀUVWKRXUV´&RRO'RZQµSHULRGRUDIWHUDQ\UHVHWIRUDQRWKHUKRXUV 7KHXQLWZLOOUHVWDUWDQGFRQWLQXHWKHFRROLQJDQGF\FOLQJLIWKHWHPSHUDWXUHIDOOVEHORZ) 725(6(78QSOXJDQGUHSOXJWKHXQLW 3/($6(&872877(03/$7(3$77(51 )25'5,//+2/(3/$&(0(17 PLUS COOLING UNIT REPLACEMENT READ BEFORE YOU START KoolR INSTALLATION 1 LOCATION: W AR 1 M 2 Appliance is for indoor use only. Never vent into a laundry closet or similar room which traps warm air. Unit must vent to an adjacent interior ventilated space close to the ceiling. Exhaust air must not be obstructed in any way. 2 SI 3 DE CO O SI L DE 4 5 6 CENTER Install unit where ALL surfaces (walls, floor and ceiling) are insulated to R-20 and protected by vapor barrier on both sides. Uninsulated concrete floors will radiate heat and humidity during summer months, forcing the unit to work inefficiently. All floors must be INSULATED! Use an insulated door with weather seal. Center pattern to door frame. Trace pattern. Flip pattern and repeat for cool side. 4 FR • • AM E Cut out drywall, warm and cool side. Cut out Stud level to drywall cutout. • • 5 ! Get help to insert cooling unit through hole. Guide cord, do not damage drywall! 6 5” Min. IVE RNAT ALTE UTOUT C L WAL POWER: Min 10” INSU LATE DOOR D WITH AIRTIG HT SEAL 2’ Min. ace sp r clea Outlet (on cool side) power must be a dedicated separately fused grounded 15-Amp 115 Volt line within reach of supplied power cord (Europe; 10-Amp 220 Volt). Line must not be shared. Do not use extension cords. RECO M OVER MENDED THE CUTO DOOR UT Min. 6’ INSULATION MINIMUM R-20 LK ING S RLES ODO ROOF RP WATE INT PA DRYWALL VAPOR BARRIER INSULATION: • • • ! DRYWALL VAPOR BARRIER Room temperature range: 52º-64º (11ºC-18ºC) ! W AR SI M DE TEMPERATURES: Select a suitable area, sized to model’s capacity, where ambient temperature will not exceed the desired storage temperature by more than 25ºF (4ºC). The temperature of the air where the unit vents its warm air must be at least 65ºF and never exceed 80ºF with 70% R.H. Lower set temperature from default 57ºF (14ºC) only if ambient condition allows. 3 SPECIAL NOTE: This unit is constructed for installation in walls up to 6 1/2” inches thick. If you install it in a thicker wall you will have to cut out an area around the air vents on cool side in order not to block airflow. Order longer screws at www.koolspace.com. • • • Slide frame over unit on cool side, guide cord through frame side notch. Screw in cooling unit to frame. Place grill on unit. NE C ICO ELBOW PLYWOOD FLOOR VAPOR BARRIER ALTERNATE WALL CUTOUT • • • • • Add tube to elbow. Insert elbow to cooling unit. NOTE: Excess condensation is caused by extreme conditions. This is not required if your room is properly insulated. WARM SIDE CENTER TUBE SEAL ALL JOINTS WATER DRAIN • MARK SLITS SIL CONTAINER AU Electronics must be protected against sudden power surges. Use a quality surge protector. INSULATION (MIN. R-20) SUB-FLOOR (STUD LUMBER) Level pattern, trace both warm and cool side. Cut out drywall. Screw in cooling unit to frame. PREPARING FOR INSTALLATION INSULATION : TROUBLE SHOOTING GUIDE Floor, ceiling and all walls of the enclosure must be insulated to minimum R-20 rating, although R-30 is recommended. Best material is foil-backed urethane foam, sealed at all joints with thermal tape. Build a proper sub-floor with a vapor barrier, and insulate to at least R-20, especially if floor is concrete.Use an insulated door. CONDITION VAPOR BARRIER : All surfaces of the enclosure must be protected by a proper vapor barrier, ideally on both inside and outside of wine/ pantry room. POWER SUPPLY : CONTROLS : Shipping damage? Contact courier company for shipping damages. Unit plugged in? Unit has a 1-min. cautionary delay between plugging in and full start-up; this is a built-in safeguard to protect compressor in case of a sudden power failure. LED display ON? Unplug unit, remove controller, check/replace fuse (0.5A slow blow, 250V, 5X20mm). see manuals at www.koolspace.com Storage temperature properly set? Unit may take a few days to achieve the desired storage temperature. Decrease your set temperature to cool. Room properly constructed with all joints airtight? Seal all cracks and joints. Check insulation requirements. Door insulated properly? If gaps are visible seal door airtight. Airflow to and from the cooling unit unobstructed? Improve circulation of air to and from the unit as directed in instructions. CONTROLLER OPERATION TO DISPLAY: ACTION DISPLAY: RUNS BUT DOES NOT COOL SUFFICIENTLY Ambient air temperature within the specified range? Make sure ambient temperature is below 80º CLEANING THE COIL: KEYS 57 Additional Trouble-Shooting information and downloadable documents are available in the “Support” area of our web site: www.koolspace.com WARNING: If unit is in “Alarm”, unplug the unit immediately. See controls table. AFTER Actual temperature: PRESS 57º 56º PRESS 70º 57º PRESS and RELEASE 57º 57º To increase: PRESS once per degree 57º 58º To decrease: PRESS once per degree 57º 56º 57º 14º 57º 57º 57º F0 IMPORTANT NOTE: • Have your wine collection adequately insured. • Install a battery-powered heat-sensitive alarm to warn of any loss of cooling due to power interruption. • Monitor your storage and ambient conditions on a regular daily basis. Be advised that Koolspace cannot in any event be liable or responsible for incidental or consequential damages. The new value will be memorized and the controller will reset automatically. TO CHANGE FROM ºF to ºC or ºC to ºF PRESS and HOLD TO CALIBRATE: PRESS and HOLD until buzzer sounds in 5 seconds ONE YEAR LIMITED WARRANTY If your Koolspace cooling unit or cabinet fails to perform as designed within one year of the date of purchase, Shanghai KOOLSPACE INC. warrants that, upon your request, it will be repaired or replaced, at our option, during the one year warranty period. This warranty applies only to the first end-user purchaser of a Koolspace unit that is purchased and used in the continental United States or Canada (excludes Alaska and Hawaii). It is not valid for subsequent purchasers, nor for units in use outside North America. The warranty period for your Koolspace unit commences on the date you purchased it and expires one year thereafter. The new value will be memorized and the controller will reset automatically. while holding PRESS and RELEASE Wait 5 seconds USE or for each degree of offset A negative offset will result in a warmer cabinet and a positive offset be memorized and the controller will reset automatically. F0 F1 FO PROOF OF PURCHASE -1 Within 10 days of purchase, complete and mail, fax or e-mail the registration sheet to Shanghai KOOLSPACE INC. Alternately, you may register your warranty on our Internet web site, www.koolspace.com. WHEN YOU MAKE A WARRANTY CLAIM, YOU MUST FORWARD A COPY OF YOUR ORIGINAL DATED BILL OF SALE TO ESTABLISH YOUR DATE OF PURCHASE. Fax: 905-362-1394. will result in a cooler cabinet. The new value will ALARM: • If the temperature exceeds 72º F the unit will shut down, a sound warning will start and the display will blink alternating with the temperature reading. • This function is disabled in the first 4 hours “ Cool Down” period or after any reset for another 4 hours. • The unit will restart and continue the cooling and cycling if the temperature falls below 72º F. Clean the unit regularly, every 3 to 4 months vacuum the cooling unit coils. VACUUM PERIODICALLY DISPLAY EXAMPLE BEFORE SET temperature: TO MODIFY SET TEMPERATURE (range is 52-64ºF): COOLING UNIT PLUG IT IN ( WAIT ONE MINUTE ) AND ENJOY! OPERATION: • Display will show detected temperature until temperature falls within 3º of SET POINT. • If temperature is above default 57º F + 1º or other preset value, after a delay of 1 minute fan will start, followed by compressor in next minute. • Unit will cycle ON/OFF based on temperature reading. Fan speeds are automatically set by controller to achieve optimum performance. • Minimum ON and OFF cycle times are imposed by software, to prevent “short cycling”. NOTE: COOLING UNIT WHEN PLUGGED IN This unit must be installed in accordance with national wiring regulations. Do not use if power cord is damaged; it must be replaced by the manufacturer or by a qualified person to avoid a hazard. Plug must remain accessible after installation. Electrical power must be a dedicated, separately fused and grounded 15 Amp, 115V line (Europe; 10-Amp 220 Volt). Test line voltage before operating. Do not use line if voltage is less than 105V. The unit must be protected against power surges and spikes. Use a good quality surge suppressor. SOLUTIONS DOES NOT RUN Seal corners, joints, gaps, vents, electrical outlets/switches, especially around door and frame. Pack larger gaps with insulation. Seal all seams with silicone caulking. Seal drywall with odorless waterproof paint. SEAL : CHECK WHAT THE WARRANTY DOES NOT COVER AL This warranty covers only defects in materials and workmanship provided by Shanghai KOOLSPACE INC. and does not cover equipment damage or malfunction from misuse, improper installation or removal of cooling unit, abuse, accident, act of God, or any unauthorized alteration or modification. The product must have been installed and operated precisely as directed in the manual which acompanies each product. Return shipping charges are not covered. Improper return shipping, inadequate packaging or shipping damage is not covered unless the unit is packaged and shipped in accordance with Shanghai KOOLSPACE INC. replacement procedures. Third party servicing of this product during the warranty period will also void the warranty, as will any evidence of tampering or alteration to the serial number and or the original dated bill of sale. GO ONLINE FOR MORE WARRANTY INFORMATION AT www.koolspace.com. TO RESET: Unplug and re plug the unit. MARK SLITS CENTER COOL SIDE