apndas-1609 - Digital Alert Systems

Transcription

apndas-1609 - Digital Alert Systems
Application Note
Version 3.0 Software - National Geocode and NPT
Configuration for the One-Net™or DASDEC™
OnJuly2016theFCC’sSixthReportandOrderonEAS(FCC15-60),wentintoeffectandincludedseveral
majorchangesrelevanttoallMonroeElectronicsOne-NetorDigitalAlertSystemsDASDECusers,twoof
whichinclude:
1. Formaladoptionof“sixzeroes”(000000)asanationallocation(FIPS)codeencompassing
everystateandcountyintheUnitedStatesanditsholdings
2. ProcessingtheNationalPeriodicTest(NPT)eventcodeimmediatelyuponreceiptandinthe
samemanoroftheEmergencyActionNotification(EAN)
ThisapplicationnoteprovidesguidancetoassuringVersion3.0userstheirdevicesareproperly
configuredforacceptingandprocessingtheEANandNPTeventcodes,notingtheymaybereceived
eitherbyCAPorover-the-air.ThefollowinginstructionsassumetheEASdevice(One-NetorDASDEC)
hasbeenpreviouslyconfigured,isworking,andtheuserisfamiliarwiththetermsandoperation–This
isNOTaninitialsetupguide.Therearetwosectionstotheseinstructions;A.ConfiguringtheCAP
Decoderand,B.ConfiguringtheNPTEventCode.
A. Configuring the CAP Decoder
1. LogintothedeviceusingyourUserNameandPassword.
2. GotoSetup>NetAlerts>CAPDecode
3. SelecttheappropriateclientconfiguredforIPAWSconnection,asintheexamplebelowwhere
theclient*IPAWSCAPischosenfromtheSelectCAPinputclientpull-downmenu.
Monroe Electronics / Digital Alert Systems
585-765-2254 | fax 585-765-9330
100 Housel Ave. | Lyndonville | NY | 14098
www.monroe-electronics.com
Revision: 1.0 Publication: APNDAS-1609
Copyright © 2016 Digital Alert Systems, a division of Monroe Electronics Inc. Information herein
is considered accurate at the time of publication. We constantly strive to improve our products and
services therefore some specifications are subject to change without notice. One-Net and
DASDEC are trademarks of Digital Alert Systems and Monroe Electronics.
Application Note
4. ToassuretheCAPDecoderprocessestheUSandStateFIPScodetheselectedFIPSGroupmust
includethesecodesinthelist.LocatetheFIPSGroupasintheexamplebelow,checkingifthe
UnitedStates(000000)andtheappropriatestateFIPSareincludedinthelist.
•
IfbothFIPS(000000)andtheappropriatestate(s)codesarepresent,clickCanceland
proceedtothenextsection–ConfiguringtheNPT(NationalPeriodicTest)EventCode.
•
IfeithertheUSFIPScodeand/ortheappropriatestate(s)codesareNOTpresentinthe
FIPSGroupcontinuetofollowthestepsbelow.
5. Intheexamplebelow,theselectedFIPSGroupisWesternNY,howeveritdoesnotincludethe
stateandUnitedStatesFIPScodes.NotingthenameoftheFIPSGroup,clicktheblueFIPSGroup
hyperlinktojumptotheSetup>AlertAgent™>FIPSGroupscreentoedittheFIPSGroup.
™
Version 3.0 Software - National Geocode and NPT Configuration for the One-Net or DASDEC
© 2016 Monroe Electronics / Digital Alert Systems. All rights reserved.
™
Page 2 of 6
Application Note
6. OnceattheManageFIPSLocationGroupListsscreen,locatetheappropriateFIPSGroupas
notedabove.Again,withthisexampleitisWesternNYthatrequiresediting.ClicktheEdit
buttonadjacenttothecorrectFIPSGroup.
7. TheselectedFIPSGroupwillexpandtoeditthegroup.ClicktheChooseFIPSStatepull-down
andselectUnitedStates(US)(00).
8. JustbelowtheChooseFIPSCountiesbox,selectAll(000)andclicktheAdd->buttontoadd
UnitedStates(000000)totheFIPSCodelisttotheright.
™
Version 3.0 Software - National Geocode and NPT Configuration for the One-Net or DASDEC
© 2016 Monroe Electronics / Digital Alert Systems. All rights reserved.
™
Page 3 of 6
Application Note
9. ReturntotheChooseFIPSStatepull-downmenuandselecttheappropriatestate.Inthis
exampleEntireNewYork(000)mustbeadded.DonotselectAnylocation(***).
10. VerifyingtheUnitedStatesandstateFIPScodeshavebeenaddedtothelistontheright,click
theAcceptChangesbuttontocompletethischange.
11. ReturntotheSetup>NetAlerts>CAPDecodescreenbyclickingtheBackbuttonintheheader
ofthewebinterface.
12. VerifytheUnitedStatesandstateFIPScodesarenowlisted.
13. IftheCAPalertswithanyEAScodewillbeconverttoEAS.Enabled…ischeckedasshown
below,theCAPdecodersetupiscompleteandproceedtosectionB,below.Otherwisecontinue
step14.
™
Version 3.0 Software - National Geocode and NPT Configuration for the One-Net or DASDEC
© 2016 Monroe Electronics / Digital Alert Systems. All rights reserved.
™
Page 4 of 6
Application Note
RARELYwouldSteps14–21berequired.ProceedONLYiftheCAPalertswithany
EAScodewillbeconverttoEAS.Disabled…isunchecked
14. IfforanyreasonthecheckboxCAPalertswithanyEAScodewillbeconverttoEAS.Disabled…
isuncheckedalimitednumberofEAScodesreceivedviaIPAWSwouldbedecoded.Toassure
properpassageoftheEAN/NPTtheassociatedgroupmustincludethesevalues.AnEASGroup
pull-downappearswithalistofEAScodesfoundwithintheselectedEASGroup.
15. Intheexampleabove,“Weather”istheselectednameinthepull-down.Clicktheblue
EASGrouphyperlinktojumptotheSetup>AlertAgent™>EASCodeGroupsscreentoeditthe
EASGroup“Weather”,addingEANandNPTtothelistfollowingthestepsbelow.
16. OnceattheManageEASCodeGroupListsscreen,locatetheappropriateEASGroupas
previouslynoted.Again,forthisexampletheWeatherlistrequiresediting.ClicktheEditbutton
adjacenttothecorrectEASGroup.
17. TheselectedEASGroupwillexpandtoeditthegroupandtheEAN:NATIONALEMERGENCY
ACTIONNOTIFICATIONandNPT:NATIONALPERIODICTESTwillautomaticallybeaddedtothe
EAScodeslist.
18. VerifytheNPTandEANcodeshavebeenaddedtothelistontherightandclicktheAccept
Changesbuttontocompletethischange.
™
Version 3.0 Software - National Geocode and NPT Configuration for the One-Net or DASDEC
© 2016 Monroe Electronics / Digital Alert Systems. All rights reserved.
™
Page 5 of 6
Application Note
19. ReturntotheSetup>NetAlerts>CAPDecodescreenbyclickingtheBackbuttonintheheader
ofthewebinterface.
20. VerifytheEANandNPTEAScodesareinthelist.ItisimportanttonoteeachEAScode
descriptionmustbeprecededbyitsthreelettercode.
21. CAPDecodersetupiscomplete.
B. Configuring the NPT (National Periodic Test) Event Code
FinalverificationshouldbedonetoassuretheAlertAgentwillforwardtheNPTeventcode.
1. GotoSetup>AlertAgent™>ManageAlertNodes
2. ThedefaultsettingsfortheNATIONALalertnodeareshownbelow.
3. IftheNATIONALalertnodesettingsarethesameasshownabove,anyEANorNPTwillbe
forwardedimmediatelyasaLiveevent.
IMPORTANTNOTE:ANYDEVIATIONSFROMTHESEALERTNODESETTINGSMAYPREVENTOR
IMPEDEFORWARDINGANEANorNPT.CONSULTTHEMANUALFORMOREDETAILED
INFORMATION.
™
Version 3.0 Software - National Geocode and NPT Configuration for the One-Net or DASDEC
© 2016 Monroe Electronics / Digital Alert Systems. All rights reserved.
™
Page 6 of 6