potbelly sandwich shop
Transcription
potbelly sandwich shop
Sheet List Table LEGENDS NOTES & ABBREVIATIONS A0.2 EGRESS PLAN A1.0 PENETRATION &TRENCHING PLAN A1.1 CONSTRUCTION PLAN A1.1a ENLARGED SERVICE LINE PLAN LANDLORD: A1.2 REFLECTED CEILING PLAN CORPORATE OFFICE PROPERTIES TRUST 6711 COLUMBIA GATEWAY DRIVE, SUITE 300 COLUMBIA, MD 21046 CONTACT: ANDREW WELKER PH: 443-285-5668 EMAIL: ANDREW.WELKER@COPT.COM A1.3 FLOOR FINISH PLAN A1.4 FURNITURE FIXTURE AND EQUIPMENT PLAN A1.5 CASEWORK PLAN A1.6 ENLARGED TOILET ROOM PLANS & DETAILS A2.0 DOOR SCHEDULES & DETAILS A2.1 FINISH SCHEDULE A2.2 FINISH SCHEDULE (CONT.) A2.3 FURNITURE FIXTURE & EQUIPMENT SCHEDULES A2.4 FURNITURE FIXTURE & EQUIPMENT SCHEDULES (CONT.) A2.5 PLUMBING SCHEDULE A2.6 LIGHTING SCHEDULE A2.7 CASEWORK SCHEDULE A2.8 CASEWORK SCHEDULE (CONT.) A2.9 CASEWORK SCHEDULE (CONT.) A3.0 EXTERIOR ELEVATIONS A4.0 INTERIOR ELEVATIONS A4.1 INTERIOR ELEVATIONS A4.2 INTERIOR ELEVATIONS A4.3 INTERIOR ELEVATIONS A4.4 INTERIOR ELEVATIONS A4.5 INTERIOR ELEVATIONS A5.0 INTERIOR DETAILS A5.1 INTERIOR DETAILS A5.2 INTERIOR DETAILS A5.3 INTERIOR DETAILS A5.4 INTERIOR DETAILS AS1.0 ARCHITECTURAL SPECIFICATIONS AS1.1 ARCHITECTURAL SPECIFICATIONS AS1.2 ARCHITECTURAL SPECIFICATIONS AS1.3 ARCHITECTURAL SPECIFICATIONS AS1.4 ARCHITECTURAL SPECIFICATIONS S1.0 ROOF FRAMING PLAN GENERAL NOTES M1.0 MECHANICAL LEGEND AND NOTES M2.0 MECHANICAL PLAN M3.0 MECHANICAL SCHEDULES M4.0 MECHANICAL DETAILS M5.0 MECHANICAL ROOF PLAN M6.0 EXHAUST HOOD DRAWINGS P1.0 PLUMBING LEGEND AND NOTES P2.0 PLUMBING SUPPLY AND SCHEDULES P3.0 PLUMBING WASTE PLAN P4.0 PLUMBING SCHEDULE P5.0 PLUMBING RISERS P6.0 PLUMBING DETAILS E1.0 ELECTRICAL LEGEND AND NOTES E2.0 POWER PLAN E3.0 LIGHTING PLAN E4.0 SYSTEMS PLAN E5.0 LIGHTING SCHEDULE E6.0 ELECTRICAL PANEL SCHEDULES E7.0 ELECTRICAL DETAILS PROJECT CONTACTS SITE VICINITY MAP CLIENT / OWNER PROJECT MGR: POTBELLY SANDWICH WORKS, INC. PROJECT LOCATION NORTH 111 N. CANAL, SUITE 850 CHICAGO, ILLINOIS 60606 DESIGN MNGR: CASSIE BURTON PH: 312-475-3847 EMAIL: CASSIE.BURTON@POTBELLY.COM CONSTRUCTION MNGR: PAULA OLDHAM PH: 774-270-6995 ARCHITECT: MEP ENGINEER: DXU, LLC 404 S. WELLS STREET, SUITE 300 CHICAGO, IL 60607 CONTACT: ANTHONY VOLPE PH: 312-955-0334 X 101 EMAIL: ANTHONY.VOLPE@DXU-STUDIO.COM AEDIFICA CASE ENGINEERING 782 MERUS COURT FENTON, MO 63026 SITE KEY PLAN A APPLICABLE CODES AREA OF WORK BUILDING CODE: PLUMBING CODE: MECHANICAL CODE: ELECTRICAL CODE: ENERGY CODE: FIRE CODE: ACCESSIBILITY CODE: 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL PLUMBING CODE 2012 INTERNATIONAL MECHANICAL CODE 2011 NATIONAL ELECTRICAL CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE 2012 NATIONAL FIRE PROTECTION ASSOCIATION MARYLAND ACCESSIBILITY CODE SITE INFORMATION/OCCUPANCY BUILDING DESCRIPTION: PROJECT DESCRIPTION: NORTH COMMERCIAL TENANT IMPROVEMENTS TO EXISTING BUILDING W1 IIB A-2 RESTAURANT 2,320 SQ.FT. 1 33'-8" APPROX. ZONING: CONSTRUCTION TYPE: OCCUPANCY CLASSIFICATION: USE GROUP: AREA OF CONSTRUCTION: # OF STORIES: BUILDING HEIGHT: ROOM DINING FIXED SERVICE/PREP AREA (SF) 1,193 SQ. FT. 669 SQ. FT. # FIXTURES REQUIRED: MEN: WOMEN: SERVICE SINK: DRINKING FOUNTAIN: # OF FIXTURES PROVIDED: MEN: WOMEN: SERVICE SINK: DRINKING FOUNTAIN: OCCUPANCY 1,193/15=80 669/200=3 TOTAL OCCUPANT LOAD: TOTAL # OF SEATS: 83 49 (INTERIOR) 12 (EXTERIOR) 1 WC, 1 LAV 1 WC, 1 LAV 1 1 1 WC, 1 LAV 1 WC, 1 LAV 1 WATER SERVICE IS PROVIDED DIRECTLY TO CUSTOMER REQUIRED EGRESS WIDTH: COMMON PATH OF EGRESS: MAXIMUM EXIT TRAVEL DISTANCE: # EXITS REQUIRED: # EXITS PROVIDED: 44" 75' 250' (W/SPRINKLER SYSTEM) 2 2 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM R 4 0 4 S. C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 SHEET TITLE COVER AND GENERAL INFORMATION SHEET NUMBER A0.0 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A0.0 COVER & GENERAL INFORMATION.DWG A0.1 JYOU COVER & GENERAL INFORMATION 5/23/2016 10:28:57 AM A0.0 PROJECT NUMBER: 16-059 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 Sheet Title BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 POTBELLY SANDWICH SHOP Sheet Number FP FLR FRA FT FV GA GALV GC GRND GWB HC HD HDR HDWD HDWR HM HORZ HR HT HVAC HW ID IF IG INSUL MFG MIN NAT NIC NL NSF NTS OA OC OD OF OFI OPNG OPP PC PERP PLAM PLEX PLYWD PM POC POS PSW PSW-HUB PSW-CS PT QT R RECEPT REF REFRIG REQ('D) REV RND RO SC SF SHT SHT MTL SIM SOL SPEC SQ ST SS STG STRUCT STL SUSP SW T&G TEL TEMP TYP UC UNO V VAL VCT VD VERT VIF WD WH XFMR ELEVATION TAG TOP = ELEVATION NUMBER BOTTOM = SHEET NUMBER 1 A0.1 1. DETAIL TAG TOP = ELEVATION NUMBER BOTTOM = SHEET NUMBER SECTION TAG TOP = ELEVATION NUMBER BOTTOM = SHEET NUMBER 1 101 2. REVISION CLOUD / TAG NUMBER DENOTES NUMBER OF ADDENDUMS TRUE NORTH SHOWS DIRECTION OF MAGNETIC NORTH PLAN NORTH AS REFERENCED TO IN ALL DRAWINGS CONTAINED IN THIS SET NORTH HEIGHT DATUM 3. ## DOOR TAG NUMBER DENOTES DOOR REFERENCE TO DOOR SCHEDULE D#### WINDOW TAG LETTER DENOTES WINDOW REFERENCE # FURNITURE / ACCESSORY / CASEWORK / EQUIPMENT / SIGNAGE TAG NUMBER DENOTES REFERENCE TO FURNITURE & ACCESSORIES SCHEDULE X### FINISH TAG NUMBER DENOTES INTERIOR FINISH MATERIAL, REFER TO FINISH SCHEDULE L-3 AFF HEIGHT TAGS HEIGHT ABOVE FINISHED FLOOR X'-X" AFF WALL TYPE TAG LETTER DENOTES WALL TYPE X WALL BLOCKING TAG LETTER DENOTES WALL BLOCKING LOCATION X 5. G.C. TO COORDINATE LAYOUT, ROUTING, AND INSTALLATION OF ALL NEW MECHANICAL, ELECTRICAL, FIRE PROTECTION, AND PLUMBING WORK WITH EXISTING MEP/FP SYSTEMS, AND WITH EXISTING STRUCTURE TO REMAIN. REPORT ALL DISCREPANCIES TO OWNER'S REP IN WRITING PRIOR TO SUBMITTING BID PACKAGE. 6. EACH CONTRACTOR OR SUBCONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, AND LICENSES REQUIRED FOR PROPER EXECUTION OF THEIR PORTION OF THE WORK. THIS EXCLUDES MAIN BUILDING PERMITS, BUSINESS & HEALTH LICENSES. 7. EACH CONTRACTOR OR SUBCONTRACTOR SHALL COMPLY WITH ALL PROVISIONS OF ALL APPLICABLE LAWS AND ORDER OF PUBLIC OFFICIALS WITH JURISDICTION FOR SAFETY OF PERSONS/PROPERTY. 8. ALL WORK SHALL BE DONE BY LICENSED CONTRACTORS AND IN CONFORMANCE WITH ALL NATIONAL, STATE, COUNTY, AND LOCAL CODES. ANY VARIANCE/NON-COMPLIANCE WITH LOCAL CODE TO BE REPORTED TO OWNER'S REP IN WRITING PRIOR TO BIDS. 0 1' 2' GRAPHIC SCALE DENOTES SCALE OF DRAWING GC TO INSTALL ALL OWNER PROVIDED DECOR ITEMS AS SHOWN IN DECOR PACKAGE TO BE FORTHCOMING, INCLUDING ALL MENU BOARDS AND MARKETING SIGNAGE. 2. POTBELLY WILL PROVIDE WITH DECOR PACKAGE: A. PLYWOOD MENU BACKERS D. BLACK METAL BRACKETS WITH SET SCREWS TO HOLD PIPE E. SOUP/SHAKE MENU BOARDS F. DESSERT MENU BOARD G. ALL FRAMED DECOR ITEMS AND KNICK KNACKS 3. GC WILL NEED TO SUPPLY: A. 2 21" 16 GAUGE FINISH NAILS FOR ALL PICTURE FRAME DECOR PIECES B. PLASTIC ANCHORS TO BE USED AT BRICK AND 2-4 SCREWS PER FRAME DEPENDING UPON SIZE, USE MORE IF LARGER THAN 24" X 36". C. CLEAR LIQUID NAILS D. MISCELLANEOUS FASTENERS AND HANGING HARDWARE INCLUDING BUT NOT LIMITED TO: 4. GENERAL DECOR INSTALLATION INSTRUCTIONS: A. ALL PICTURE FRAMES ARE NAILED TO THE WALL WITH NAIL GUN. USE MINIMUM OF 4 NAILS PER PIECE. B. PLATES TO BE SET ON LEDGES, GLUED ON TOP AND BOTTOM WITH CLEAR LIQUID NAILS. C. ALL KNICK KNACKS TO BE GLUED DOWN WITH CLEAR LIQUID NAILS. D. HAND WASHING SIGNS TO BE AFIXED TO WALL NEAR PAPER TOWEL DISPENSERS WITH DOUBLE STICK TAPE (PROVIDED ON BACK OF SIGN). E. DO NOT USE LIQUID NAILS TO ATTACH ARTWORK TO WALLS UNLESS UNABLE TO NAIL DIRECTLY. 5. MAIN MENU BOARD INSTALLATION INSTRUCTIONS: A. G.C. & ALL SUBS TO FAMILIARIZE THEMSELVES WITH THE BASE BUILDING AND TO VERIFY WITH LANDLORD BEFORE MODIFYING OR ATTACHING NEW CONSTRUCTION TO BASE BUILDING. EDGE. 11. G.C. ASSUMES COMPLETE RESPONSIBILITY WHEN OWNER FURNISHED ITEMS ARE ACCEPTED AND RECEIVED BY G.C. 12. G.C. TO ENSURE THAT A COMPLETE SET OF CONSTRUCTION DOCUMENTS IS GIVEN TO ALL SUBCONTRACTORS PRIOR TO BID SUBMISSION. 13. DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENT. IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY OWNER'S REP IMMEDIATELY. ALL DIMENSIONS ARE FROM FACE OF FINISH SURFACE TO FACE OF FINISH SURFACE UNLESS OTHERWISE NOTED. 14. ALL WOOD IN CONTACT WITH CONCRETE AND AT EXTERIOR LOCATIONS MUST BE PRESSURE TREATED MOISTURE RESISTANT WOOD. F. IF THE MENU WILL BE HANGING FROM THE CEILING: THE PIPE WILL BE SUPPLIED WITH TWO EYE BOLTS ATTACHED. USE THE PROPER HARDWARE FOR ANCHORING INTO THE CEILING OR 15. ALL WALL CONSTRUCTION FACING PLUMBING FIXTURE AREAS MUST UTILIZE MOISTURE RESISTANT GYPSUM BOARD UNLESS OTHERWISE NOTED. 16. G.C. TO FILL AND STAIN ALL NAIL HOLES. CEILING OR STRUCTURAL JOIST TO THE EYE BOLTS IN THE PIPE. G. WHEN THE PIPE IS SECURE, HANG THE ASSEMBLED MENU PANELS IN THE ORDER INDICATED IN INSTALL GUIDE IN CONSTRUCTION BINDER. 17. G.C. TO CAULK ALL BASE AND CHAIR RAIL TO DISSIMILAR MATERIALS. 18. G.C. TO PROVIDE AS BUILT DRAWINGS (CONSISTING OF REDLINED CONSTRUCTION DRAWINGS) TO OWNER'S REP WITHIN TWO WEEKS OF COMPLETION OF PROJECT, PRIOR TO FINAL PAYMENT. 19. G.C. TO COVER WINDOWS AS REQUIRED, DURING CONSTRUCTION WITH CRAFT PAPER TO 10 FT. CONFIRM WITH CENTER RULES & REGULATIONS. THE BRACKETS OVER THE PILOT HOLES. THIS WILL ALSO ALLOW FOR ADJUSTMENT LATER IF THE MENU PANELS ARE NOT HANGING SQUARE TO THE PIPE WHEN FINISHED. C. TAKE 1 CARRIAGE BOLT AND 1 WING NUT FROM THE BAG AND BOLT THE BAG WITH THE REST OF THE HARDWARE TO ONE OF THE PLYWOOD PANELS FOR THE OPERATIONS TEAM TO USE LATER FOR ATTACHING THE MENU PANELS. D. IF THE MENU REQUIRES A STANDARD WALL MOUNT WITH BRACKETS: MOUNT THE BRACKETS WITH SCREWS AND/OR ANCHORS IN THE SPECIFIED LOCATION, MAKING SURE TO LEAVE AT LEAST E. NUMBER OF BRACKETS REQUIRED PER MENU: 6. 22. INSTALLATION & FINISHING OF WOOD FLOORING, CONCRETE STAIN AND KITCHEN PAINT TO BE BID AS NIGHT WORK. 23. 24. 25. ALL LIGHT SWITCHES, THERMOSTATS, SECURITY ALARMS, ELECTRICAL OUTLETS, ETC. MUST BE MOUNTED TO MEET ALL GOVERNING ACCESSIBILITY REQUIREMENTS FOR FLOOR & HEIGHT CLEARANCES AND ONE HAND GRASPING OPERATION. FLAME SPREAD RATINGS FOR INSULATION AND FINISHES: A. ALL CONCEALED BATT & BLANKET INSULATION TO BE USED IN THE WALL AND ATTIC IS TO BE CLASS A OR BETTER, FLAME SPREAD 25 OR LESS & A SMOKE-DEVELOPED RATING OF 450 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84. B. ALL WALL & CEILING FINISHES TO BE CLASS B OR BETTER, FLAME SPREAD 26-75 WITH MAXIMUM SMOKE DEVELOPED OF 450 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84. C. ALL INTERIOR TRIM TO BE CLASS 2, FLAME SPREAD 76-200 WITH MAXIMUM SMOKE DEVELOPED OF 450. ALL DECORATIVE MATERIALS SHALL BE NONCOMBUSTIBLE OR MAINTAIN FLAME RESISTANCE IN ACCORDANCE WITH SECTION 807.2 D. FLOOR COVERINGS TO HAVE A FLAME SPREAD RATING NOT TO EXCEED 75. ALL COMBUSTIBLE INTERIOR FINISH & TRIM ITEMS ARE TO BE APPLIED DIRECTLY TO A NON-COMBUSTIBLE BASE. 26. PROVIDE AND INSTALL OCCUPANCY SIGN IN A CONSPICUOUS LOCATION IN ACCORDANCE WITH STATE & LOCAL CODES. 27. IF THE LANDLORD OR BUILDING REPRESENTATIVE REQUIRES X-RAYING OF FLOOR, ALL COSTS SHALL BE INCLUDED IN THE GENERAL CONTRACTOR'S ORIGINAL BID. 28. G.C SHALL VERIFY THE LOCATION OF ALL UTILITIES. SOUP/SHAKE MENU BOARD INSTALLATION INSTRUCTIONS: A. INSTALL PLASTIC WALL ANCHORS AND #10 SCREWS IN THE DRYWALL, CENTERED AND SPACED TO MATCH THE DISTANCE BETWEEN THE D-RING HANGERS IN THE BACK OF THE MENUS. LEAVE THE SCREW HEADS FAR ENOUGH AWAY FROM THE WALL TO CATCH THE D-RING HANGERS AND MAKE SURE THE MENU IS HANGING FLAT AGAINST THE WALL. 7. DESSERT MENU INSTALLATION INSTRUCTIONS: A. CENTER MENU FRAME OVER ICE CREAM CABINET IN BOTH WIDTH AND HEIGHT OR AS PER PSW REP DIRECTION. B. NAIL TO WALL WITH NAIL GUN USING MINIMUM 8 NAILS. C. PLACE CHALKBOARD PANEL ON HOOKS IN CENTER OF MENU FRAME. D. TOUCH UP NAIL HOLES/BLEMISHES AS NEEDED ON MENU FRAME WITH TOUCH UP PAINT. 8. A-FRAME TOPPER INSTALLATION INSTRUCTIONS: A. REMOVE BOTH EXISTING BLACK FRAMES THAT HOLD THE CHALKBOARDS AND PRINTED 20. KEEP DRIVEWAYS AND ENTRANCES CLEAR AT ALL TIMES. EACH SUBCONTRACTOR SHALL REMOVE RUBBISH AT THE COMPLETION OF HIS WORK. PROMPTLY REPAIR ANY DAMAGE DONE TO ADJACENT PROPERTY/TENANT SPACES AT NOT COST TO OWNER. TWO (2) FIRE EXTINGUISHERS TO BE SUPPLIED BY OWNER, LOCATED BY FIRE MARSHAL, INSTALLED BY G.C. FIRE EXTINGUISHERS: LARSON #MP5 WITH UL RATING OF 2A-10B:C A R 4 0 4 S. C Wells H S t ., I T E Suite 300 C T S Chicago, + IL P L A 60607 N P: N 312 E R 955 S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. HANGING APPLICATION FOR MENU BOARDS) WELDED-LINK CHAIN, CUT TO SIZE ON SITE (IF HANGING APPLICATION FOR MENU BOARDS) G.C SHALL VERIFY ALL EQUIPMENT, MILLWORK, AND OTHER ITEMS BEING FURNISHED BY OWNER OR OWNER'S CONTRACTORS FOR WHICH G.C IS RESPONSIBLE FOR INSTALLING ARE IN GOOD CONDITION. 21. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM C. BOX OF HARDWARE WITH QUANTITIES SPECIFIC TO MENU SIZE INCLUDING: 10. S S REFER TO FURNISHINGS, FIXTURE & EQUIPMENT SHEET FOR ALL EQUIPMENT LOCATIONS. REFER TO EQUIPMENT MANUAL & ENGINEERING DWGS. FOR EQUIPMENT REQUIREMENTS. NOTIFY OWNER'S REP OF ANY DISCREPANCIES. G.C. TO COMPLY WITH LANDLORD'S AND OWNER'S RULES AND REGULATIONS REGARDING CONSTRUCTION WITHIN THE BUILDING. GC & ALL SUBCONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH THE BASE BUILDING AND TO VERIFY WITH THE LANDLORD BEFORE MODIFYING OR ATTACHING NEW CONSTRUCTION TO BASE BUILDING. GC SHALL PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THE WORK. 9. 1. ALL EXISTING CONDITIONS, STRUCTURAL AND MECHANICAL CONNECTIONS TO ALL EXISTING BUILDING SERVICES MUST BE FIELD VERIFIED PRIOR TO SUBMISSION OF BIDS. ANY DISCREPANCIES SHALL BE REFLECTED AND NO ADJUSTMENT TO BID PRICE SHALL BE MADE AFTER BID SUBMISSION. SUBMISSION OF BID SHALL BE UNDERSTOOD AND CONSTRUED AS CONTRACTOR HAVING VERIFIED ALL EXISTING CONDITION. WHETHER OR NOT SHOWN ON DRAWINGS AND HAVING TAKEN INTO ACCOUNT ANY ADJUSTMENT NECESSARY TO FULFILL THE DESIGN INTENT IN FULL AND COMPLETELY. 4. ELEVATION BENCHMARK KEY NOTE NUMBER DENOTES REFERENCE TO KEY NOTES ON SPECIFIED SHEET GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VISIT THE SITE AND VERIFY ALL SITE CONDITIONS PERTAINING TO THIS PROJECT PRIOR TO SUBMISSION OF BIDS. ANY DISCREPANCIES FOUND DURING SITE INVESTIGATION TO BE REPORTED TO OWNER'S REP IN WRITING PRIOR TO BID SUBMISSION. G.C. TO ENSURE THAT EXISTING STRUCTURE IS NOT ALTERED OR DAMAGED WITH EXCEPTION OF MODIFICATIONS SHOWN ON DRAWINGS. ALL INSTALLATIONS AND ALL CONNECTIONS TO EXISTING BUILDING MECHANICAL SYSTEMS SHALL BE COORDINATED WITH AND PERFORMED UNDER THE SUPERVISION OF THE LANDLORD'S REPRESENTATIVE. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A0.1 LEGENDS NOTES & ABBREVIATIONS.DWG FOS FRP LL MAX MC MDF MECH MEP INFORMATION INDIRECT WASTE KITCHEN EQUIPMENT CONSULTANT LANDLORD MAXIMUM MECHANICAL CONTRACTOR MEDIUM DENSITY FIBERBOARD MECHANICAL MECHANICAL, ELECTRICAL AND PLUMBING MANUFACTURER MINIMUM NATURAL NOT IN CONTRACT NIGHT LIGHT NATIONAL SANITATION FOUNDATION NOT TO SCALE OVER ALL ON CENTER OUTSIDE DIAMETER OUTSIDE FACE OWNER FURNISHED ITEM OPENING OPPOSITE PLUMBING CONTACTOR PERPENDICULAR PLASTIC LAMINATE PLEXIGLAS PLYWOOD PROJECT MANAGER POINT OF CONNECTION POINT OF SALE POTBELLY SANDWICH WORKS POTBELLY SANDWICH WORKS HUBBARD WAREHOUSE POTBELLY SANDWICH WORKS CONSTRUCTION SERVICES PAINT QUARRY TILE RADIUS RECEPTACLE REFERENCE REFRIGERATOR REQUIRED REVISED/REVISION ROUND REVERSE OSMOSIS SOLID CORE SQUARE FEET SHEET SHEET METAL SIMILAR SOLID SPECIFICATION(S) SQUARE STAIN STAINLESS STEEL STORAGE STRUCTURAL STEEL SUSPENDED SOFTENED WATER TONGUE & GROOVE TELEPHONE TEMPORARY TYPICAL UNDERCOUNTER UNLESS NOTED OTHERWISE VENT VALIDATION VINYL COMPOSITION TILE VENDOR VERTICAL VERIFY IN FIELD WOOD WATER HEATER TRANSFORMER WITH THE WASHERS AND WING NUTS (THESE CANNOT BE USED WITH THE TOP FRAME). B. PRE-DRILL 5 PILOT HOLES IN THE TOP OF ONE SIDE OF THE A-FRAME STRUCTURE. (THE TOP FRAME ONLY FASTENS TO ONE SIDE SO IT CAN STILL OPEN AND CLOSE) C. PLACE THE TOP FRAME ON TOP OF THE FULLY OPENED A-FRAME AND ADJUST SO THAT IT SITS LEVEL. D. SCREW UP THROUGH THE A-FRAME INTO THE BOTTOM OF THE TOP FRAME WITH THE 5 PROVIDED SCREWS (SEE SKETCH). SHEET TITLE LEGENDS NOTES & ABBREVIATIONS JYOU FIXT FLEX FOC FOG FOH FOIC INFO IW KEC DECOR INSTALL NOTES SHEET NUMBER A0.1 3/18/2010 12:52:23 PM FIN FIO AIR CONDITIONING ACCESSIBLE ACOUSTICAL CEILING TILE ADJUSTABLE ABOVE FINISHED FLOOR ALUMINUM AMPERAGE APPROXIMATE ARCHITECTURAL BOARD BUILDING BLOCKING BOTTOM OF BEAM BACK OF HOUSE CABINET CONDENSATE DRAIN CIRCUIT CEILING CLEAR/CLEARANCE CONSTRUCTION MANAGER CEMENT CONCRETE MASONRY UNIT CENTERS COMPANY COORDINATE CENTER CENTERLINE COLUMN COMPARTMENT CONCRETE CONTINUOUS CONSTRUCTION COORDINATE CERAMIC TILE COLD WATER DEGREES DIAMETER DIMENSION DOWN DETAIL DISHWASHER DRAWINGS EACH ELECTRICAL CONTRACTOR ELECTRICAL ELEVATION EQUAL EQUIPMENT EXISTING EXPOSED EXTERIOR FLOOR CLEANOUT FURNITURE, FURNISHINGS AND EQUIPMENT FINISHED FURNISHED & INSTALLED BY OWNER FIXTURE FLEXIBLE FACE OF CABINET FACE OF GLAZING FRONT OF HOUSE FURNISHED BY OWNER & INSTALLED BY CONTRACTOR FACE OF STUD FIBERGLASS REINFORCED PANEL FIRE PROTECTION FLOOR FRAME FOOT/FEET FIELD VERIFY GAUGE GALVANIZED GENERAL CONTRACTOR GROUND GYPSUM WALL BOARD HOLLOW CORE HEAD HEADER HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING VENTILATING AIR CONDITIONING HOT WATER INSIDE DIAMETER INSIDE/INTERIOR FACE INDEPENDENT GROUND INSULATION GENERAL NOTES PROJECT NUMBER: 16-059 AC ACC ACT ADJ AFF ALUM AMP APPROX ARCH BD BLDG BLKG BOB BOH CAB CD CKT CLG CLR CM CMNT CMU CNTRS CO COORD CTR CL COL COMP CONC CONT CONST COORD CT CW DEG DIA DIM DN DTL DW DWG(S) EA EC ELEC ELEV EQ EQUIP EXIST EXP EXT FCO FFE SYMBOLS LEGEND BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 ABBREVIATIONS OCCUPANCY CALCULATION KITCHEN - SERVICE/PREP= 669 SQ. FT. / 200 SF PER OCC = 3 OCCUPANTS 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM ASSEMBLY - RESTAURANTS = 1,193 SQ. FT. /15 SF PER OCC = 80 (49 INTERIOR DINING SEATS & 12 EXTERIOR SEATS) TOTAL = 83 OCCUPANTS (80 - DINING ROOM, 3 KITCHEN) A R 4 0 4 S. C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 KEY NOTES 1 ADA TABLE LOCATION THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. EXITING CALCULATION WALK-IN COOLER/ FREEZER SERVICE LINE PREP ROOM GENERAL NOTES A. DASHED LINE INDICATES CLEAR PATH OF EGRESS NOTE: Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. 8'-1" 18'-5" ISSUE DATE 6'-3" 26'-8" 6'-3" 16'-11" 14'-11" 30'-10" 4'-11" PROJECT NUMBER: 16-059 QUEUING AREA BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 MAXIMUM TRAVEL DISTANCE ALLOWED (SPRINKLED) - 250' MAXIMUM TRAVEL DISTANCE PROVIDED DINING 42'-9" KITCHEN 63'-6" TOILET ROOM VESTIBULE 4'-11" " 2 8'- ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 5'-0" 8'-0" " 3" " 8'- 9'-3" 3 6'- 17'-2 6'-7" 26'-9" R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A0.2 EGRESS PLAN.DWG 4'-2" 2'-0" MUSICIAN AREA DINING ROOM WOMEN'S TOILET ROOM MEN'S TOILET ROOM EGRESS PLAN UTILITY CLOSET NORTH JYOU SHEET TITLE 01 EGRESS PLAN SCALE: 1/4"=1'-0" A0.2 3/18/2010 12:53:00 PM SHEET NUMBER KEY NOTES 63'-10" 61'-6" 61'-0" 1 FLOOR DRAIN. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION. 2 FLOOR SINK. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION. 3 NOT USED 4 STUB-UP PENETRATION TO BE LOCATED ON CENTERLINE OF WALL OR AS REQUIRED PER CONDITIONS. 5 FLOOR PENETRATION FOR TOILET. REFER TO MANUFACTURER'S CUTSHEET FOR STUB-UP LOCATION RELATIVE TO FINISHED WALL. 6 WASTE LINE PENETRATIONS. SEE PLUMBING SHEETS FOR INDIVIDUAL LINE SPECIFICATIONS. 7 NOT USED 8 FLOOR CLEANOUT. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. 52'-3" 44'-5 1/2" 44'-4" 28'-11" 28'-5" 3'-0" 1'-11" 4 P206 P208 1 P206 2 2 1 P208 8'-10 1/2" 10'-0" 10'-10 1/2" 13'-9" 16'-5" 16'-10 1/2" 2 7'-8" P206 1'-6" 4'-6" 2'-6" 5'-0" 2 4 1'-8" 4 2'-0" 4 P206 P208 1 4 5 A. G.C. RESPONSIBLE FOR CONCRETE SLAB AFTER INSTALLING UTILITIES UNDER SLAB. COORDINATE WITH LANDLORD. 5 P208 1 GENERAL NOTES PROJECT NUMBER: 16-059 15'-1 1/2" 14'-8" 14'-3" 13'-1 1/2" 10'-1" 8'-8" 8'-0 1/2" BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 21'-9 1/2" ISSUE DATE 1 ISSUE DD SET 95% SET 6 P208 4 P208 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.0 TRENCHING & PENETRATION PLAN.DWG 1 DATE 04-26-2016 05-23-2016 1'-5" 4'-6" NORTH PENETRATION & TRENCHING PLAN JYOU SHEET TITLE SHEET NUMBER TRENCHING & PENETRATION PLAN SCALE: 1/4" = 1'-0" A1.0 ---- 01 KEY NOTES WALL TYPE LEGEND 4'-4" AFF 5C 5D 4'-0" AFF COOLER / FREEZER WALL: BY MANUFACTURER EXISTING STRUCTURAL BUILDING COMPONENTS (COLUMNS, BEAMS, TRUSSES) TO REMAIN. MAINTAIN EXISTING RATING AS REQ'D BY LOCAL CODES. 3 ELECTRICAL PANELS. REFER TO ELECTRICAL DRAWINGS 4 NOT USED PARTIAL HEIGHT WALL (QUEUING LINE WALL): 20 GA 3 58" MTL STUDS 16" OC AND 2"X2"' STEEL PIPES WITH 34" LUAN PLYWOOD ON BOTH SIDES TO SPECIFIED HEIGHT. WALK-IN COOLER/ FREEZER SERVICE LINE PREP ROOM 71'-2 1/2" VIF INTERIOR DIMENSION 1'-2" 6'-0" 29'-3" 5 NOT USED 6 NOT USED 7 WROUGHT IRON STANCHIONS WITH QUEUING LINE CHAIN. REFER TO DETAIL 13/A5.0. 8 G.C. CONSTRUCTED DIEWALL WITH CASEWORK PANELS AT SERVICE COUNTER. REFER TO SHEET A1.5. 9 FRAMED OPENING WITH 11-1/2" CURB FOR REACH-IN COOLER. COORDINATE WITH EQUIPMENT. REFER TO DETAIL 04/A5.0. 10 CLOSURE ANGLE. SEE DETAIL 09/A5.0. 23'-6 1/2" 6'-2" 11 PROVIDE CONTINUOUS BLOCKING IN PARTITION FOR WALL-HUNG LAVATORY, GRAB BARS, BABY CHANGING STATION, ETC. REFER TO ENLARGED PLAN DETAIL13/A1.6 12 EXISTING ALUMINUM STOREFRONT 13 OVERHEAD CABINETS AT BACKLINE, REFER TO INTERIOR ELEVATIONS FOR LOCATION. PROVIDE BLOCKING IN WALL. 14 STAINLESS STEEL CORNER GUARD 15 NOT USED 12 16 2 13 13 4 1 2 3 14 A5.0 02 A4.0 03 A4.3 01 A4.3 03 A4.0 1 2'-3" 14 2'-3" 1 A. GC TO VERIFY ALL DIMENSIONS AND NOTIFY PSW CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 13 A1.6 D005 3A 2 3A 3 12 8 9 3'-9" 7 TYP 5'-3" D001 9'-7" 3 03 A4.1 2A 02 A4.1 2A 8'-6" HOLD A5.1 2A 2 2 D002 4 6" 2A 2 01 A4.2 2 14 1 D007 2 6'-0 1/2" 2 04 A4.1 2 7'-9" COOLER DIM 3'-8 1/2" 01 A4.1 3 D009 10 5'-1" 01 A4.4 2A 02 A4.1 5'-8" 02 A4.3 C. ALL DIMENSIONS ARE TAKEN FROM FACE OF FINISH WALL & INSIDE OF DOOR JAMB U.N.O. 2 D008 D006 25'-10" 2 9" 16 01 A4.0 B. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES. 29'-1" VIF INTERIOR DIMENSION 03 A4.1 5'-0" TYP 7" A1.1a C 7" 8 7 14'-5 1/2" COOLER DIM 01 3'-8 1/2" 4 2 02 A4.4 4'-6" 5'-7" TOILET ROOM VESTIBULE 02 A3.0 12 7'-0" D010 2 MUSICIAN AREA 01 CONSTRUCTION PLAN 12 03 A3.0 12 77'-9 1/2" VIF INTERIOR DIMENSION DINING ROOM C Wells H S t ., I T E Suite 300 C T S Chicago, + IL P L A 60607 N P: N 312 E R 955 S 0334 D. REFER TO SHEET A1.4 FOR FURNITURE, EQUIPMENT & SHELVING. THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 E. REFER TO PLUMBING SHEETS FOR FIXTURE LOCATIONS & SPECIFICATIONS. G. ALL MEANS OF EGRESS DOOR OPENING HARDWARE SHALL BE OPERATED BY A SINGLE HAND WITHOUT MEANS OF TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. ALL DOORS EQUIPPED WITH PANIC HARDWARE MUST MAINTAIN A 32" CLEAR WIDTH. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED: A. 8.5 L.B.F. (37.7N) FOR EXTERIOR DOORS. B. 5.0 L.B.F. (22.2N) FOR INTERIOR DOORS. 2A H. DOORS INDICATED AS PART OF THE REQUIRED MEANS OF EGRESS SHALL HAVE HARDWARE WHICH IS READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR SPECIAL EFFORT. 2 12 R 4 0 4 S. F. REFER TO SHEET A2.0 FOR DOOR SCHEDULE AND DETAILS. 1 04 A4.3 PROVIDE BLOCKING IN WALL FOR WALL HUNG MENU BOARD AND BOH SHELVING. SEE INTERIOR ELEVATIONS FOR MORE INFORMATION. GENERAL NOTES 7'-10" 7'-11" 10 2A 01 A3.0 16 3 D004 22'-7 1/2" 12'-5" 04 A4.0 2 8'-9" 13 6 1 3'-10" 4 2'-3" ALIGN 1 1 3'-2 1/2" 16 2 A ILLINOIS DESIGN FIRM # 184.006688 CROSSHATCH INDICATES WALLS TO BE INSULATED. PROVIDE R13 MINIMUM BATT INSULATION. QUEUING AREA 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.1 CONSTRUCTION PLAN.DWG 8 2 12 J. PROVIDE FIRE TREATED WOOD BLOCKING WHERE REQUIRED. WOMEN'S TOILET ROOM MEN'S TOILET ROOM UTILITY CLOSET NORTH SCALE: 1/4" = 1'-0" I. ADDITIONAL ROOF PENETRATIONS REQUIRED BY PSW SHALL BE INSTALLED BY LANDLORD'S ROOF CONTRACTOR AT PSW'S EXPENSE. VIOLATIONS OF THE LANDLORD'S ROOF REQUIREMENTS WILL RESULT IN A SURRENDER OF PSW'S OR CONTRACTOR'S SECURITY DEPOSIT. PSW SHALL HAVE THE OPTION TO SET ALL CURBS AND SLEEVES FOR ROOF PENETRATIONS PRIOR TO ROOF WORK BEING COMPLETE. SHEET TITLE CONSTRUCTION PLAN JYOU 4 85" 2'-10" AFF SHEET NUMBER A1.1 3/18/2010 1:14:04 PM 4A 5B EXISTING DEMISING WALL. PATCH AND REPAIR GYP. BD. AS REQUIRED TO MAINTAIN EXISTING RATING. CONFIRM WALL CONSTRUCTION AND NOTIFY PSW OF ANY DISCREPANCIES OR ISSUES. PROJECT NUMBER: 16-059 4 41" 6 41" 4 1'-11" AFF FURRED WALL TO 6" ABOVE CLG: 20 GA 3 58" MTL STUDS 16" OC WITH 58" TYPE "X" GWB ON ONE SIDE TO 13'-0" AFF. DRYWALL SCREWS AT 12" OC. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. 7 FURRED PLUMBING WALL TO 6" ABOVE CLG: 20 GA 3 5/8" MTL STUDS @ 4 & 6" MTL STUDS @ 4A 16" OC WITH 85" GREEN BOARD ON ONE SIDE TO 6" ABOVE CLG. DRYWALL SCREWS AT 10" OC. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. EXISTING WALL 5A 1 BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 4 87" 3A 5D 6 PLUMBING WALL TO 6" ABOVE CLG: 20 GA 3 5/8" MTL STUDS @ 3 & 6" MTL STUDS @ 3A WITH 58" GREEN BOARD ON ONE OR BOTH SIDES TO 6" ABOVE CLG. DRYWALL SCREWS AT 10" OC. 45 DEGREE MTL STUD REINFORCEMENT AT 48" OC ABOVE CLG LINE TO STRUCTURE ABOVE. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. 7 1/4" 3 5C 4 4"1 EXISTING WALL 2A 5B 5 81" 4 78" 2 5A FULL HEIGHT PARTITION WALL: 20 GA 3 85" MTL STUDS 16" OC @ 2, & EXISTING STUDS @ 2A WITH 58" TYPE "X" GWB ON BOTH SIDES TO DECK OR 6" ABOVE CLG. IF APPLICABLE. DRYWALL SCREWS AT 12" OC. 45 DEGREE MTL STUD REINFORMCEMENT AT 48" OC ABOVE CLG LINE TO STRUCTURE ABOVE. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. PARTIAL HEIGHT WALL : 20 GA 3 58" MTL STUDS 16" OC AND 2"X2"' STEEL PIPES WITH 1/2" PLYWOOD ON BOTH SIDES TO SPECIFIED HEIGHT BELOW. REFER TO WALL SECTIONS ON A5.4 FOR MORE INFORMATION ON CONSTRUCTION. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. 10 1/2" EXISTING CONSTRUCTION TO REMAIN, PATCH & REPAIR TO LIKE NEW CONDITION 1 KEY NOTES EXISTING CONSTRUCTION TO REMAIN, PATCH & REPAIR TO LIKE NEW CONDITION 4 41" 4A 4 85" 5C 5D 4 4"1 5B 6 PLUMBING WALL TO 6" ABOVE CLG: 20 GA 3 5/8" MTL STUDS @ 3 & 6" MTL STUDS @ 3A WITH 58" GREEN BOARD ON ONE OR BOTH SIDES TO 6" ABOVE CLG. DRYWALL SCREWS AT 10" OC. 45 DEGREE MTL STUD REINFORCEMENT AT 48" OC ABOVE CLG LINE TO STRUCTURE ABOVE. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. 5A 1'-11" AFF 2'-10" AFF 5B 5C 4'-4" AFF 5D 4'-0" AFF 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM FURRED WALL TO 6" ABOVE CLG: 20 GA 3 58" MTL STUDS 16" OC WITH 58" TYPE "X" GWB ON ONE SIDE TO 13'-0" AFF. DRYWALL SCREWS AT 12" OC. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. A R 4 0 4 S. COOLER / FREEZER WALL: BY MANUFACTURER 7 FURRED PLUMBING WALL TO 6" ABOVE CLG: 20 GA 3 5/8" MTL STUDS @ 4 & 6" MTL STUDS @ 4A 16" OC WITH 58" GREEN BOARD ON ONE SIDE TO 6" ABOVE CLG. DRYWALL SCREWS AT 10" OC. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. 8 C H Wells S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. PARTIAL HEIGHT WALL (QUEUING LINE WALL): 20 GA 3 58" MTL STUDS 16" OC AND 2"X2"' STEEL PIPES WITH 34" LUAN PLYWOOD ON BOTH SIDES TO SPECIFIED HEIGHT. CROSSHATCH INDICATES WALLS TO BE INSULATED. PROVIDE R13 MINIMUM BATT INSULATION. GENERAL NOTES A. GC TO VERIFY ALL DIMENSIONS AND NOTIFY PSW CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 02 A5.4 C. ALL DIMENSIONS ARE TAKEN FROM FACE OF FINISH WALL & INSIDE OF DOOR JAMB U.N.O. 5C D. REFER TO SHEET A1.4 FOR FURNITURE, EQUIPMENT & SHELVING. 3'-2" 10'-5" 2'-8" ALIGN B. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES. PROJECT NUMBER: 16-059 4 6 41" EXISTING WALL FULL HEIGHT PARTITION WALL: 20 GA 3 58" MTL STUDS 16" OC @ 2, & EXISTING STUDS @ 2A WITH 85" TYPE "X" GWB ON BOTH SIDES TO DECK OR 6" ABOVE CLG. IF APPLICABLE. DRYWALL SCREWS AT 12" OC. 45 DEGREE MTL STUD REINFORMCEMENT AT 48" OC ABOVE CLG LINE TO STRUCTURE ABOVE. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. PARTIAL HEIGHT WALL : 20 GA 3 58" MTL STUDS 16" OC AND 2"X2"' STEEL PIPES WITH 1/2" PLYWOOD ON BOTH SIDES TO SPECIFIED HEIGHT BELOW. REFER TO WALL SECTIONS ON A5.4 FOR MORE INFORMATION ON CONSTRUCTION. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 3A 5A 5 81" 3 EXISTING WALL 4 87" 2A 7 1/4" 2 4 78" 1 10 1/2" WALL TYPE LEGEND ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 E. REFER TO PLUMBING SHEETS FOR FIXTURE LOCATIONS & SPECIFICATIONS. 29'-8" 5B 6'-10" 3'-6" F. REFER TO SHEET A2.0 FOR DOOR SCHEDULE AND DETAILS. 3'-0" G. ALL MEANS OF EGRESS DOOR OPENING HARDWARE SHALL BE OPERATED BY A SINGLE HAND WITHOUT MEANS OF TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. ALL DOORS EQUIPPED WITH PANIC HARDWARE MUST MAINTAIN A 32" CLEAR WIDTH. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED: A. 8.5 L.B.F. (37.7N) FOR EXTERIOR DOORS. B. 5.0 L.B.F. (22.2N) FOR INTERIOR DOORS. 5C 01 A5.4 03 A5.4 04 A5.4 02 A5.4 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.1A ENLARGED CONSTRUCTION PLAN.DWG 3'-10" 8'-9" 01 A5.4 H. DOORS INDICATED AS PART OF THE REQUIRED MEANS OF EGRESS SHALL HAVE HARDWARE WHICH IS READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR SPECIAL EFFORT. J. PROVIDE FIRE TREATED WOOD BLOCKING WHERE REQUIRED. NORTH ENLARGED SERVICE LINE PLAN JYOU SHEET TITLE 01 ENLARGED SERVICE LINE CONSTRUCTION PLAN SCALE: 3/8" = 1'-0" A1.1a 3/18/2010 1:14:04 PM SHEET NUMBER KEY NOTES 29'-9" 05 A5.2 5'-0" 3'-6" 5 1/2" EQ EQ 1'-6" 1'-6" 2'-6" 1'-6" 10'-11" HOOD DIMENSION CENTERLINE 01 ENLARGED REFLECTED CEILING PLAN SERVICE LINE OPEN TO STRUCTURE 10'-1" A.F.F. CL-06 WALK-IN COOLER/ FREEZER CL-08 3 SUBMARINE DUCT WITH ROTATING PROPELLER. REFER TO DETAIL 13/A5.2 AND MECHANICAL DRAWINGS FOR MORE INFO 4 NOT USED 5 KITCHEN EXHAUST HOOD. REFER TO MECH DRAWINGS FOR MORE INFORMATION NOT USED 7 NOT USED 8 MARKETING HANGING SIGN, REFER TO DETAIL 08/A5.2 9 NOT USED 10 NOT USED 11 CEILING HUNG MARKETING SIGN/MENU. 12 CUT DOWN CEILING HUNG TRACK TO MATCH GIVEN DIMENSION. 13 3/8"=1'-0" SCALE: 2x4 VINYL CEILING TILE - WHITE 10'-6" A.F.F. CL-01 GYP. BD. BULKHEAD W/ WOOD TRIM 01 1 L500 1'-6" L210 3'-1" C 3'-6" EQ 1'-6" A1.2 5 L302 L302 L602 2' X 2' LAY-IN METAL CLG. PANEL. IN METAL CEILING GRID W/ 12" X 12" PATTERN (FULL PANELS TO BE CENTERED OVER SERVICE AREA) L302 04 A5.2 5 L502 L104 L102 2'-6" 1'-2" L208 L617 L617 7'-6" S203 8 11 L107 L107 L107 2 5'-10" 3'-6" L500 EQ EQ 03 A5.2 L200 L500 7'-8" L208 EQ PT-04 L305 L617 L208 L615 L109 L208 L618 L109 S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 C EQ 5'-0" EQ EQ 5'-0" EQ EQ 5'-0" S100 L100 L100 L100 L500 L100 MUSICIAN AREA DINING ROOM OPEN TO STRUCTURE OPEN TO STRUCTURE PT-19 REFLECTED CEILING PLAN PT-19 L100 L100 L208 L615 L618 L208 L615 L617 EQ L100 R S 0334 C. COORDINATE LOCATIONS OF WALL MOUNTED J-BOXES WITH ELEVATIONS. D. ALL MECHANICAL DIFFUSERS AND SUPPLY GRILLES TO BE PAINTED TO MATCH SURROUNDING MATERIAL. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 E. SPRINKLER HEADS (IF REQUIRED) WITHIN 10'-0" OF OVEN SHOULD BE HIGH HEAT RATED. H. PROVIDE ADEQUATE STRUCTURAL SUPPORT FOR EACH FIXTURE. S L502 2'-0" E 955 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. G. ALL DIMENSIONS ARE FROM WALL FINISH TO WALL FINISH. J. CONFIRM RECEIPT AND STORE FIXTURES UPON ARRIVAL AT SITE. L601 WINDOW 02 H 3'-0" L102 L601 C Wells F. ALL EXPOSED DUCTWORK, BEAMS, JOISTS, DECKING, PIPES, CONDUIT, ETC. AT CEILING SPACE THROUGHOUT DINING & QUEUING AREAS SHALL BE PAINTED AS NOTED. EQ 8'-0" L109 4'-0" L615 8'-0" 1'-6" 2'-0" TOILET ROOM VESTIBULE C 5'-10" EQ EQ EQ B. REFER TO SHEET A2.4 FOR SIGNAGE SCHEDULE. 8'-6" A.F.F. L502 R 4 0 4 S. A. REFER TO SHEET A2.6 FOR LIGHT FIXTURE SCHEDULE 3'-0" C 5'-10" S L202 2 L210 1'-6" L617 L502 EQ EQ L615 L107 " 3'-0 EQ L202 EQ S220 L207 S 10 A5.2 EQ L617 EQ EQ 7'-7 1/2" L208 L615 S100 GENERAL NOTES L203 7'-0" L614 EQ EQ EQ L615 S EQ C EQ EQ 1'-6" C L104 L602 L302 2'-6" 8'-10 1/2" PAINTED GYP. BD. CEILING L602 EQ L613 L500 S 1'-8 1/2" L208 1'-8 1/2" L617 3'-0" 5'-0" C L615 A CLD TO BE USED ON TRACK FIXTURES ONLY IF REQUIRED BY CODE. ELECTRICAL ENGINEER TO VERIFY. MANUF L613 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM LEGEND PREP ROOM 8'-0" A.F.F. PT-19 PREFABRICATED COOLER CEILING PROJECT NUMBER: 16-059 QUEUING AREA 2 ILLINOIS DESIGN FIRM # 184.006688 15 A5.2 5'-0" 1'-6" X 1'-6" GYP. BOARD SOFFIT AT BAG IN THE BOX. 6 1'-9" 4'-6" 1 BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 5'-0" 2'-0" 8'-0" HOOD DIMENSION CENTERLINE ALIGN 3'-6" 10'-6" 4" 2'-6" 8'-2" HOOD DIMENSION CENTERLINE HOOD DIMENSION CENTERLINE K. PROVIDE AND INSTALL CONDUIT, J-BOXES, AND WIRING FOR ALL FIXTURES. L500 WOMEN'S TOILET ROOM 8'-6" A.F.F. PT-04 MEN'S TOILET ROOM 8'-6" A.F.F. L. COORDINATE LOCATIONS OF EMERGENCY LIGHTING AT BACK SERVICE LINE WITH INTERIOR ELEVATIONS. UTILITY CLOSET 8'-6" A.F.F. PT-04 M. REFER TO DETAIL 9/A5.2 FOR PENDANT LIGHT JBOX MOUNTING DTL. NORTH PT-04 SCALE: 1/4" = 1'-0" N. REFER TO DETAIL 14/A5.2 FOR CEILING FAN MOUNTING DTL O. REFER TO DETAIL 7/A5.2 & 12/A5.2 FOR TRACK LIGHT MOUNTING DETAILS. SHEET TITLE REFLECTED CEILING PLAN SHEET NUMBER A1.2 ROOM FINISH SCHEDULE WALLS CEILING WOOD PAINT, WALLCOVERING, WOOD CEILING HEIGHT OPEN, PAINT PAINT OPEN QUARRY TILE CERAMIC TILE, PAINT METAL PANEL 10'-1" QUARRY TILE QUARRY TILE FRP, PAINT ACT 10'-6" CERAMIC TILE WOOD PAINT, WALLCOVERING GYP. BOARD, PAINT 8'-6" GYP. BOARD, PAINT 8'-6" CONCRETE WOOD SERVICE LINE QUARRY TILE PREP AREA TOILET ROOM VESTIBULE TAG LEGEND DESCRIPTION SIZE FT01 QUARRY TILE 6"X6" FT03 CERAMIC TILE WHITE 1"X1" CERAMIC TILE BLACK 1"X1" GROUT REMARKS 1 LEAVE OUT FLOOR FINISH AS NOTED LATICRETE #45 RAVEN REFER TO ARCHITECTURAL SPECIFICATIONS SHEETS FOR INSTALLATION INSTRUCTIONS 2 FREEZER FLOOR FINISH INCLUDED WITH COOLER/FREEZER ASSEMBLY. LATICRETE #45 RAVEN REFER TO ENLARGED PLAN DETAIL FOR PATTERN. REFER TO ARCHITECTURAL SPECIFICATIONS SHEETS FOR INSTALLATION INSTRUCTIONS 3 NOT USED LATICRETE #45 RAVEN REFER TO ENLARGED PLAN DETAIL FOR PATTERN. REFER TO ARCHITECTURAL SPECIFICATIONS SHEETS FOR INSTALLATION INSTRUCTIONS OPEN OPEN, PAINT QUEUING COMMENTS WOMEN'S TOILET ROOM CERAMIC TILE CERAMIC TILE CERAMIC TILE, PAINT MEN'S TOILET ROOM CERAMIC TILE CERAMIC TILE CERAMIC TILE, PAINT GYP. BOARD, PAINT 8'-6" WALK-IN COOLER QUARRY TILE QUARRY TILE STAINLESS STEEL STAINLESS STEEL 8'-0" WALK-IN FREEZER STAINLESS STEEL STAINLESS STEEL STAINLESS STEEL STAINLESS STEEL 8'-0" UTILITY CLOSET QUARRY TILE QUARRY TILE FRP, PAINT ACT 8'-6" QUEUING AREA FT04 3'X3' SCORING WITH 1/8"W X 1/8"D MAX. CONCRETE TOPPING FT05 REFER TO ARCHITECTURAL SPECIFICATIONS SHEETS FOR INSTALLATION AND FINISHING INSTRUCTIONS N/A 4 NOT USED 5 FLOOR SINK/DRAIN LOCATION. REFER TO PLUMBING DRAWINGS FOR DETAILS. 6 SLOPE 1/8" PER FOOT TO DRAINS. 7 WALK OFF MAT FT16 WALK-IN COOLER/ FREEZER SERVICE LINE FT05 FT01 WB04 WB01 12 X 9 APPLY BEAD OF SILICONE AROUND PERIMETER OF DINING ROOM WHERE WOOD BASE MEETS CONCRETE FLOOR. USE CLEAR SILICONE. REFER TO CONSTRUCTION BINDER FOR INSTALLATION INSTRUCTIONS N/A PREP ROOM FT01 WB01 FT01 10 A5.3 P206 5 14 A5.3 P206 P208 03 A5.3 5 P206 5 5 P208 5 GENERAL NOTES P206 P208 6" A R 4 0 4 S. C Wells H S t ., I T E Suite 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 WB01 5 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM 5 6 A. REFER TO FINISH SCHEDULE ON SHEET A2.1 & A2.2 FOR MORE INFORMATION. 02 A5.3 B. ALL FLOORING AND BASE MATERIAL TO BE INSTALLED AS PER PSW SPECIFICATIONS, NO SUBSTITUTIONS. 6 15 A5.3 P208 C. 5 D. ALL AREAS INDICATED TO RECEIVE WATERPROOFING WHICH ARE NOT SLAB ON GRADE TO HAVE FULL WATERPROOFING INSTALLED AND RUN 6" UP WALL AND MILLWORK. 6 TOILET ROOM VESTIBULE P208 5 5'-0" 6 FT03 1 11 A5.3 LINE DESIGNATES LIMITS OF WATERPROOFING. FT04 E. ALL AREAS INDICATED TO RECEIVE WATERPROOFING WHICH ARE SLAB ON GRADE TO HAVE WATERPROOFING INSTALLED 6" UP WALL & MILLWORK AND 6" OUT ON FLOOR. THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 F. ALL CUT TILES TO BE PUMICED SMOOTH. WB02 4'-8" 1 2 6 H. PROVIDE LEVELING AGENT AS DEEMED NECESSARY TO ALLOW ACCEPTABLE FINISH FOR FLOOR TILE. 08 A5.3 0" 3'- 5 3'- 0" 08 A5.3 G. INSTALL QUARRY TILE COVE BASE AT SERVICE LINE DIE WALL AFTER CABINETRY HAS BEEN SET. P208 05 A5.3 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.3 FLOOR FINISH PLAN.DWG CONCRETE BASE PROJECT NUMBER: 16-059 DINING FLOOR KEY NOTES *REFER TO SHEET A2.1 FOR FINISH SCHEDULE* BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 ROOM NAME FLOOR FINISH LEGEND 7 6" 09 A5.3 CONCRETE SCORING PATTERN START POINT DINING ROOM FT05 FT05 WB04 WB04 WOMEN'S TOILET ROOM FT03 WB02 01 FT04 MEN'S TOILET ROOM FT03 FT04 UTILITY CLOSET FT01 NORTH WB01 FLOOR FINISH PLAN SHEET NUMBER WB02 FLOOR FINISH PLAN SCALE: 1/4" = 1'-0" A1.3 3/18/2010 1:17:52 PM MUSICIAN AREA JYOU SHEET TITLE KEY NOTES 1 INSTALL 3-COMP SINK MINIMUM OF 3" OFF OF SIDE WALLS, IF SPACE ALLOWS. 2 INTERIOR WINDOW SHADES AT WINDOWS AS INDICATED 3 BAG-N-BOX. REFER TO DETAIL 11/A5.0 4 PROVIDE BLOCKING IN WALL 5 INSTALL MANAGER'S DESK MINIMUM OF 2" OFF OF SIDE WALL. 6 7 GC TO PROVIDE AND INSTALL 4'-0" LENGTH OF STRAIGHT LINK MACHINE CHAIN, #4 SIZE AND COMBINATION PAD LOCK FOR CO2 TANK. APPLY SILICONE SEAL AROUND PERIMETER OF SAFE. USE CLEAR SILICONE. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. WALK-IN COOLER/ FREEZER SERVICE LINE PREP ROOM M121 M114 E403 M113 E401 E226 E410 E304 E248 E201 E409 M109 P204 A. REFER TO FFE SCHEDULES ON SHEET A2.2-A2.5 FOR TAG DESIGNATIONS. M115 B. ALL EQUIPMENT AND INSTALLATION TO MEET SDF STANDARDS OR EQUIVALENT. M107 E402 E215 P601 M107 P603 P406 P211 P805 M143 P600 M141 P201 E247 C. G.C. TO SET EQUIPMENT AND FURNITURE AS PER THIS SHEET. MAINTAIN CLEARANCE WIDTHS AS PER ACCESSIBILITY GUIDELINES AND DIMENSIONS AS PER SHEET A0.1. P605 P401 5 1 7 D. HATCHING INDICATES MILLWORK ITEMS, REFER TO SHEET A1.2 FOR FURTHER INFORMATION. F302 2 E. WHERE GC IS REQUIRED TO INSTALL ANY FIXED SEATING, TABLES, COUNTERS, ETC., A REMOVABLE SCREW IS TO BE TAPPED INTO FLOORING, NOT NAILED. F121 F302 M146 E250 E252 E403 M103 M106 E251 3 S204 E105 6 M111 M136 S201 E207 P702 S221 13 F121 A1.6 F302 F301 2 S223 E406 F117 E304 E226 F502 S101 M113 E221 E302 4 E208 S203 E103 M123 F115 F300 F201 F301 2 F203 F110 F206 F300 F301 F109 F501 F301 F206 F109 F501 F301 F206 S219 F108 F301 P210 M135 S207 S208 E213 E222 E219 TOILET ROOM VESTIBULE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 M104 S220 4 S213 S225 S224 F200 F200 F300 F102 F101 P807 S225 F500 S222A F201 F107 4 S216A F200 F300 F301 ISSUE DATE P205 P102 S207 M112 P401 P210 P102 P715 M155 S209 M111 E223 F102 F200 F300 F102 F200 F300 F101 E221 E222 P800 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.4 FURNITURE FIXTURE AND EQUIPMENT PLAN.DWG P405 F300 E221 F200 F300 F112 F300 F301 F407 13'-4" F301 F113 F201 S101 S222A F407 F121 F121 F121 F121 F302 F302 F302 F302 MUSICIAN AREA DINING ROOM F301 F100 F201 F301 F112 F304 F200 F101 F100 F200 F200 SHEET TITLE WOMEN'S TOILET ROOM MEN'S TOILET ROOM FF & E PLAN UTILITY CLOSET JYOU 11'-0" F302 P410 4 PROJECT NUMBER: 16-059 QUEUING AREA BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 GENERAL NOTES NORTH 01 FURNITURE, FIXTURE AND EQUIPMENT PLAN SCALE: 1/4" = 1'-0" A1.4 6/18/2009 5:13:48 PM SHEET NUMBER KEY NOTES QUEUING AREA WALK-IN COOLER/ FREEZER SERVICE LINE PREP ROOM C122 2 5 GC TO SUPPLY DURAROCK AT SERVICE LINE SIDE OF END WALL AS INDICATED. A1.5 7 4 HIGH CHIP CUBBIE TO SIT ON WALL C300 8 COORDINATE THE LOCATION OF PANELS AND SPRAY PAINT PLYWOOD SUBSTRATE WITH BLACK PAINT TO HIDE EXPOSED REVEAL BETWEEN MILLWORK PANELS. COORDINATE AS NEEDED AND PAINT PRIOR TO PANEL INSTALL. 9 1" METAL SUPPORT POST. PROVIDED BY RETAIL INSTALLED BY GC. 10 CHALK BOARD PANELS BETWEEN METAL SUPPORT POSTS. PROVIDED BY RETAIL, INSTALLED BY GC. 11 2" PIPE LEG SUPPORT. PROVIDED BY RETAIL INSTALLED BY GC. 12 SOLID SURFACE POS SHROUDS. INSTALLATION OF SHROUDS SHOULD BE COORDINATED WITH POS INSTALLATION. 13 ADD GROMMET LOCATIONS IN FIELD AT POS COUNTER. 03 C304 A1.5 8 C121 TYP. C303 C301 C205 1'-6" C204 6 6 7 C203 C202 6 6 C201 W312 V208 W317 W319 W304 W320 COOLER TRIM W305 BEADBOARD W315 V208 2'-6" W305 BEADBOARD W304 W305 BEADBOARD 1 W304 W305 BEADBOARD W304 C134 TOILET ROOM VESTIBULE W304 V209 W322 1'-6" C123 C200 W316 3 W305 BEADBOARD W312 W304 W322 W312 V208 C125 W305 BEADBOARD GENERAL NOTES A. REFER TO CASEWORK SCHEDULE SHEET A2.7 & A2.8 FOR INFORMATION. MUSICIAN AREA DINING ROOM WOMEN'S TOILET ROOM MEN'S TOILET ROOM UTILITY CLOSET NORTH C. GC TO TOUCH UP CASEWORK PIECES AS NEEDED UPON COMPLETION USING VENDOR PROVIDED TOUCH UP KIT. D. GC TO CAULK ALL EXPOSED SEAMS, JOINTS, ETC. WITH CLEAR SILICONE SEALANT. DO NOT CAULK MOVEABLE CASEWORK PIECES TO WALL. CASEWORK PLAN A R 4 0 4 S. C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 A104 11 11 A104 A103 10 10 A103 A100 9 9 A100 8" 1'-10" 8" 2" 1'-10" Count 4 2 2 1 1 A107 12 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.5 CASEWORK PLAN.DWG SCALE: 1/4" = 1'-0" CASEWORK ACCESSORIES ITEM A100 A103 A104 A105 A107 B. ALL MDF TRIM TO COME PRIMED FROM VENDOR. GC TO APPLY FINAL FINISH IN FIELD. REFER TO CASEWORK SCHEDULE FOR FINISH DESIGNATIONS. SHEET TITLE CASEWORK PLAN 1'-1" 01 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM JYOU 1 NOT USED AFFIX MILLWORK PANELS & TOP CAP TO FACE/TOP OF DIE WALL AS PER MILLWORK SHOP DRAWINGS. 02 6 4 6 C306 C206 REFER TO ELEVATION SHEETS FOR LOCATION AND FINISH OF PICTURE FRAME. 1'-2" SHEET NUMBER 02 ENLARGED DETAIL SCALE: 1/2" = 1'-0" 03 ENLARGED DETAIL SCALE: 1/2" = 1'-0" A1.5 6/18/2009 5:14:17 PM 6 3 W305 5'-0" W305 BEADBOARD REFER TO ELEVATION SHEETS FOR LOCATION OF CHAIR RAIL AT TILE. V201 1'-10" W309 W304 2 PROJECT NUMBER: 16-059 6" 1 X 2 WOOD TRIM AT FINISH TRANSITION. REFER TO ELEVATIONS FOR MORE INFORMATION. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 C130 1 1'-8 1/2" SURFACE MOUNTED LIGHT FIXTURE 1'-6" WALL SCONCE SURFACE MOUNTED LIGHT FIXTURE CLEANING CHECKLIST PAPER TOWEL DISPENSER MOTION SENSOR LIGHT SWITCH SOAP DISPENSER MIRROR A 1'-6" FLOOR MOUNTED WATER CLOSET H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. 5'-0" WALL HUNG LAVATORY COAT HOOK A 01 C Wells ILLINOIS DESIGN FIRM # 184.006688 4'-4" B.O. SIGN EQ. 3'-4" B.O. MIRROR GLASS 2'-10" T.O. SINK 3'-4" REFER TO CUTSHEET 3'-0" 1'-5" 1'-7" 3'-3" 3'-0" 5'-0" EQ. TOILET PAPER DISPENSER R 4 0 4 S. 4'-0" T.O. LIGHT SWITCH 36" HORIZONTAL GRAB BAR 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM D C TOILET ROOM ELEVATIONS SCALE: 1/2" = 1'-0" KEYNOTES 1 TOILET ROOM SIGNAGE - MEN & WOMEN WITH SYMBOL & BRAILLE. REFER TO DETAIL 07/A1.6 FOR MOUNTING LOCATION. 2 TOILET ROOM SIGNAGE - MEN & WOMEN VINYL LETTERS APPLIED TO DOOR AT A MINIMUM OF 49" A.F.F. MEASURED TO THE BASELINE OF THE LOWEST TACTILE CHARACTER AND A MAX OF 60" A.F.F. TO THE BASELINE FO THE HIGHEST TACTILE CHARACTER. PT05 WT04 3'-8" 14 COURSES WT-0X 7'-6" 6" TYP 7'-5" 2'-0" TYP 1'-0" TYP 3'-0" TYP PROJECT NUMBER: 16-059 18" H VERTICAL GRAB BAR SURFACE MOUNTED LIGHT FIXTURE BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 TOILET ROOM CABINET 9'-2" NOTE: PROVIDE CEMENT BOARD FROM FINISHED FLOOR TO 4'-0" AFF. PROVIDE GREEN BOARD FROM 4'-0" TO FINISHED CEILING GENERAL NOTES P611B P210 B P406 01 A1.6 B. REFER TO SHEET A2.1 & A2.2 FOR FINISH SCHEDULE. D C. REFER TO SHEET A2.3 AND A2.4 FOR FFE SCHEDULES. 1'-6" M209 C S208 D. REFER TO ELEVATIONS THIS SHEET FOR ACCESSORY MOUNTING HEIGHTS. 1 5'-3" 4'-1" 5'-2" PROVIDE INSULATION AT HOT WATER AND DRAIN PIPES UNDER LAVATORY SHEET TITLE ENLARGED TOILET ROOM PLANS & DETAILS PROVIDE WATERPROOFING UP WALL 6" 11 SINK SECTION SCALE: 1" = 1'-0" JYOU 2'-10" T.O. SINK 2'-5 1/4" B.O. SINK HOLD WATER/DRAIN LINES AS HIGH AS POSSIBLE 07 7" 7" PROVIDE CLEAR SEALANT AT LAVATORY TO WALL CONNECTION 3'-4" B.O. MIRROR GLASS - 07 OPP DATE 04-26-2016 05-23-2016 A. REFER TO DETAIL 06/A1.6 FOR TYPICAL FINISH CALLOUTS IN TOILET ROOMS. A 1'-6" TYP ISSUE DD SET 95% SET R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.6 ENLARGED TOILET ROOM PLANS & DETAILS.DWG SCALE: 1/2" = 1'-0" 3'-5" 1'-8 1/2" 07 ISSUE DATE SHEET NUMBER 12 NOT USED SCALE: 13 ENLARGED TOILET ROOM PLAN SCALE: 1/2"=1'-0" A1.6 2/4/2010 1:55:52 PM SCALE: 1/2" = 1'-0" TYPICAL DOOR ELEV. 3'-0" TYP M204 3'-3" TYP M203 TOILET WALL FINISH ELEV. 3'-6" TYP 06 1'-0" TYP 4" WB02 HARDWARE GROUPS W300 07 - SET #8 AT PREP TO DINING DOOR TYPE G AT RESTROOM DOOR TYPE G (1) PR. HAGER BUTT HINGES, ANODIZED DARK BRONZE, UL LISTED, HAGER HINGE CO., MODEL #BB1279 4 -1/2"X4-1/2" 10 A - LENGTH TO FIT DOOR HEIGHT PER MANUFACTURER (1) SIMPLEX 5021 XS WL 744 41 KEYPAD LOCK (1) WALL STOP, US10B, HAGER HINGE COMPANY, MODEL #236W (1) 6"x34" KICK PLATES, HAGER, MODEL #190S-10B (1) CLOSER, HAGER 5100 X RW/PA DBZ (1) ROCKWOOD 461 KICKDOWN US10B (1) DOOR VIEWER, IVES MODEL #U698 B3 SILENCERS (1) PR. HAGER BUTT HINGES, ANODIZED DARK BRONZE, UL LISTED, HAGER HINGE CO., MODEL #BB1279 4 -1/2"X4-1/2" 10 A - LENGTH TO FIT DOOR HEIGHT PER MANUFACTU (1) WALL STOP, US10B, HAGER HINGE COMPANY, MODEL #236W (1) 6"x34" KICK PLATES, HAGER, MODEL #190S-10B (1) CLOSER, HAGER 5100 X RW/PA DBZ (1) ROCKWOOD 461 KICKDOWN US10B (1) AVALON 613 SILENCERS SET #9 AT SERVICE/PREP DOOR TYPE C CONTACT ELIASON FOR MORE INFORMATION ITEM NO: SCP-12-RHPTBELLY ROD WAGNER: 269-615-1105 | RWAGNER@ELIASONCORP.COM SET #1A AT EXTERIOR ENTRY DOORS TYPE B 11 - (1) (1) (1) (1) (1) SET #7 AT CAFE DOOR TYPE E DOOR TRIM DETAIL B. PROVIDE DOOR SILENCERS (3 PER DOOR) AT ALL DOORS. ALL EXTERIOR DOOR BUTTS TO HAVE NON-RISING PINS. ALL HARDWARE TO HAVE OIL RUBBED ANTIQUE BRASS FINISH. NO POLISHED BRASS. C. PINE OR POPLAR ARE ACCEPTABLE WOOD SPECIES FOR TRIM WHERE MDF IS NOT USED. SELECT AVAILABLE SPECIES & USE THROUGHOUT. D. HOLLOW METAL DOORS AND FRAMES TO BE PAINTED, WOOD DOORS TO BE STAINED IN FIELD. SEE AS1.2 FOR MORE INFO. E. GC TO VERIFY IF EXISTING HARDWARE ( PROVIDED BY LANDLORD) MEETS CODE ON ALL EMERGENCY EXIT DOORS. IF NOT, GC TO PROVIDE AND INSTALL HARDWARE. VERIFY HARDWARE TYPE WITH PSW CONSTRUCTION MANAGER. F. G.C. TO CONTACT POTBELLY VENDOR FOR HARDWARE. BRIDGET JELONEK LAFORCE, INC. PH: 630.325.1950 x1603 EM: bjelonek@laforceinc.com DOOR, FRAME AND HARDWARE SCHEDULE NUMBER FRP AS SCHEDULED 1X6 WOOD CASING W308 1/4" SHIM SPACE HOLLOW METAL FRAME. 1X3 WOOD JAMB W318 DOOR AS SCHEDULED 3/4" SERVICE LOCATION NOMINAL SIZE FRAME MAT FIN HARDWARE HEAD JAMB THRSHLD DOOR TYPE MAT FIN PRVD INSTL DETAIL DETAIL DETAIL TYPE PRVD INSTL REMARKS EXISTING HARDWARE WITH NEW CORES - CORES PROVIDED AND INSTALLED BY VD - REFER TO GENERAL NOTE E D001 ENTRY (EXISTING) 3'-0" X 8'-0" X 1 3/4" AL/G - B ALUM - EX EX EX EX 06/A5.3 1A LL LL D002 UTILITY CLOSET (2)3'-0" X 7'-0" X 1 3/4" HM PT-33 G SC ST-2 G.C. G.C. 06/A2.0 06/A2.0 08/A5.3 8 G.C. G.C. D003 DINING / SERVICE 3'-0" X 2'-6" X 1 3/4" WD ST-3 E SC PLAM G.C. G.C. - 12&13/A2.0 03/A5.3 7 G.C. G.C. DUAL ACTION DOOR SWING D004 SERVICE / PREP 3'-0" X 7'-0" X 1 3/4" WD ST-3 C SC PLAM G.C. G.C. 07/A2.0 11/A2.0 -- 9 G.C. G.C. DUAL ACTION DOOR SWING D005 WALK-IN REFRGIERATOR BY V.D. - - - V.D. V.D. - - - - V.D. V.D. D006 WALK-IN FREEZER BY V.D. - - - V.D. V.D. - - - - V.D. V.D. D007 PREP/DINING (HALL) 3'-0" X 7'-0" X 1 3/4" HM PT-33 G SC ST-2 G.C. G.C. 06/A2.0 06/A2.0 08/A5.3 8 G.C. G.C. D008 WOMEN'S TOILET ROOM 3'-0" X 7'-0" X 1 3/4" HM PT-33 G SC ST-2 G.C. G.C. 06/A2.0 06/A2.0 5 G.C. G.C. PROVIDE HC 'WOMENS' SIGNAGE D009 MEN'S TOILET ROOM 3'-0" X 7'-0" X 1 3/4" HM PT-33 G SC ST-2 G.C. G.C. 06/A2.0 06/A2.0 5 G.C. G.C. PROVIDE HC 'MENS' SIGNAGE D010 REAR EXIT (EXISTING) 3'-0" X 7'-0" X 1 3/4" HM PT-33 B HM PT-33 EX EX EX EX 09/A5.3 6 LL LL ADDRESS/SIGNAGE AS REQ'D BY LL D011 SIDE ENTRY (EXISTING) 3'-0" X 8'-0" X 1 3/4" AL/G - B ALUM - EX EX EX EX 09/A5.3 1A LL LL 3/4" PREP C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 ALL DOOR ACTIVATING HARDWARE SHALL BE INSTALLED BETWEEN 3'-2" A.F.F & 3'-8" A.F.F. SCALE: 1/2" = 1'-0" R 4 0 4 S. A. CONTACT ELIASON FOR MORE INFORMATION ITEM NO: SCPCF-RHPTBELLY ROD WAGNER: 269-615-1105 | RWAGNER@ELIASONCORP.COM 01 A GENERAL NOTES HAGER (OR EQUAL) ROTON HINGES, TO MATCH STOREFRONT SYSTEM, UL LISTED, HAGER HINGE CO., MODEL #780-224HD - LENGTH TO FIT DOOR, HEIGHT PER MANUFACTURER CLOSER, LCN, MODEL #4041 EDA W/ PA DKBZ ALUMINUM THRESHOLD BY NATIONAL GUARD-(SUPPLIED BY G.C.) PERIMETER WEATHER STRIPPING = NATIONAL GUARD NGP # 160V DKB SWEEPS = NATIONAL GUARD 1025 VDKB WITH SILENCERS 4" X 16" INT. PUSH PLATE, HAGER, #30S-US10B-SP313 PANIC BAR, VON DUPRIN, #22EO-SP313 EXIT ONLY- IF REQUIRED BY CODE EXTERIOR PULL, VON DUPRIN, #230DT- SP313 (NO CYLINDER HOLE) (1) (1) (3) 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM EXISTING HARDWARE WITH NEW CORES - CORES PROVIDED AND INSTALLED BY VD - REFER TO GENERAL NOTE E THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. PROJECT NUMBER: 16-059 SET #5 (1) PR. HAGER ROTON HINGES, ANODIZED DARK BRONZE, UL LISTED, HAGER HINGE CO., MODEL #780-224HD - LENGTH TO FIT DOOR, HEIGHT PER MANUFACTURER (2) 6"X34" KICK PLATES, HAGER, MODEL #190S-US10B (1) CLOSER, LCN, MODEL #4041 EDA DKB (1) PUSH BAR - PANIC HARDWARE, VON DUPRIN, #22EO-SP313 (1) EXTERIOR DOOR PULL, VON DUPRIN, #230DT-SP313 (NO CYLINDER HOLE) (1) 4"X16" INTERIOR PUSH PLATE, HAGER, #30S-US10B (MOUNT BELOW PUSH BAR) (1) THRESHOLD BY NATIONAL GUARD-DARK BRONZE ANODIZED (1) SWEEP W/ SILENCERS, NATIONAL GUARD 1025 VDKB (1) HOLD OPEN, IVES, #FS544 SP313 WOOD CASING DOOR STOP AS NOTED AT INTERIOR ENTRY BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 SET #2 ISSUE DATE 06 HEAD/JAMB DETAIL SCALE: 3" = 1'-0" 07 HEAD DETAIL SCALE: 3" = 1'-0" 08 NOT USED ISSUE DD SET 95% SET SCALE: DATE 04-26-2016 05-23-2016 DOOR TYPES 1 2" SERVICE SERVICE 1 2" PLYWOOD R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.0 DOOR SCHEDULES & DETAILS.DWG 1X6 WOOD CASING PLYWOOD 3/4" 7'-0" W300 NOT USED ELIASON - SCP12 - RHPTBELLY (SINGLE DOOR) 3/4" SOLID CORE LAMINATED 1/4" SHIM SPACE 3-5/8" METAL STUD WITH WOOD BLOKING 5 1/2" 1/4" SHIM SPACE 5 1/2" 1/4" SHIM SPACE 3-5/8" METAL STUD WITH WOOD BLOKING EXISTING A C 3/4" B 1 2" PLYWOOD STRIP 3 4" PANEL CLEAT 1 2" PLYWOOD STRIP HOLLOW METAL FRAME PAINT PT-33 1X3 WOOD JAMB CASEWORK PANEL 3 4" DINING DINING 1X6 WOOD JAMB CAFE DOOR 11 SCALE: 3" = 1'-0" 12 JAMB DETAIL CAFE DOOR SCALE: 3" = 1'-0" 13 JAMB DETAIL DOOR VIEWER CASEWORK PANEL 1X6 WOOD JAMB JAMB DETAIL PANEL CLEAT HOLLOW METAL DOOR PAINT PT-33 3" = 1'-0" SOLID CORE DOOR STAIN ST-02 NOT USED SHEET TITLE DOOR SCHEDULES & DETAILS SHEET NUMBER EXISTING D SCALE: ELIASON - SCPCF - RHPTBELLY (RIGHT-HAND SINGLE DOOR) STRAIGHT CUT TOP & BOTTOM EDGE. 3'-0" 4" W318 5'-0" PREP HOLLOW METAL FRAME PAINT PT-33 2'-6" FRP AS SCHEDULED E F G A2.0 3/18/2010 1:58:02 PM SERVICE 3'-0" JYOU FRP AS SCHEDULED FRP AS SCHEDULED ITEM # DESCRIPTION MANUFACTURER SPECIFICATION SIZE GROUT FURN INSTALL PSW SPEC REQD COMMENTS FLOORING FT01 FT02 FT03 FT04 QUARRY TILE QUARRY TILE (ALTERNATE) PORCELAIN TILE DALTILE DALTILE DALTILE OQ84-RED PAVER - SMOOTH; SKU #OQ84661PB OQ81 - RED PAVER - SURETREAD; SKU #0Q81661PB KEYSTONE D317; 1" BISCUIT PORCELAIN HEXAGON SKU #D3171HEXMS1P KEYSTONE D311; 1" BLACK PORCELAIN HEXAGON SKU #D3111HEXMS1P 6" X 6" 6" X 6" 1" X 1' LATICRETE #45 RAVEN LATICRETE #45 RAVEN LATICRETE #45 RAVEN GC GC GC ALTERNATE TO BE USED ONLY IF REQ'D BY LOCAL JURISDICTION; CONTACT: REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM GC FOR ENTRY VESTIBULE & RESTROOMS AS PER DRAWINGS; REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM GC FOR ENTRY VESTIBULE & RESTROOMS AS PER DRAWINGS; REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM DALTILE FT05 CONCRETE TOPPING DIAMOND GRIND SURFACE W/ A PLANETARY HEAD DIAMOND GRIND SYSTEM. SCORE CUT SYSTEM AND INSTALL WITH MONGOOSE DECORATIVE SCORE CUT SCOFIELD CONCRETE SEALANT SAW SYSTEM. APPLY 2 COATS OF SEALANT. 3' X 3' SCORING WITH 1/8"W X 1/8"D. MAX. NA GC GC CAULK ALL EXPANSION JOINTS. REFER TO ARCHITECTURAL SPECIFICATIONS & CONSTRUCTION MANUAL FOR COMPLETE SPECIFICATIONS. FT06 PORCELAIN TILE ERGON 24" X 24" LATICRETE #45 RAVEN GC GC CONTACT: MICHAEL MONTORSI (630) 539-4470 OR MMONTORSI@M2ILTD.COM FT07 WOOD PLANK 1 1/2" FACE STAGGERED NA GC GC FT11 CONCRETE FLOOR TOPPER/FILLER MAPEI PLANITOP X REPAIR MORTAR NA NA GC GC FOR USE ON EXISTING CONCRETE SURFACES IN NEED OF REPAIR. REFER TO CONSTRUCTION MANUAL FOR FURTHER INFORMATION. FT12 LUXURY VINYL TILE (LVT) AMTICO AROSMS43 STRIA BASALT 18" X 18" NA GC GC USE MANUFACTURER RECOMMENDED ADHESIVE AND INSTALLATION METHOD. CONTACT RACHEL STOCKARD FOR PRICING 630-335-0939 FT16 WALK OFF MAT IMPACT SPECIALTIES HELIX Z-1 TILE, BLACK WITH BLACK FRAME 12" X 9" NA GC GC CONTACT LOCAL IMPACT SPECIALTIES REPRESENTATIVE, CONTACT JENNY MCCARTHY FOR PRICING 312.859.3689 FT17 PORCELAIN TILE ERGON ARCHITECT RESIN, HONGKONG TAUPE 809G7R 32"X32" LATICRETE #45 RAVEN GC GC FT18 PORCELAIN TILE DALTILE VERANDA TONES, REDLAND HILLS P531 SKU #P5016531P 6.5" X 20" LATICRETE #45 RAVEN GC GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM GC INTEGRAL COVE BASE; CONTACT: REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM GC GC INTEGRAL COVE BASE; CAULK BASE AT FLOOR MATERIAL; CONTACT: REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM VD GC ECOLOGIK GRIGIO GC GC PORCELAIN TILE 1" X 1" LATICRETE #45 RAVEN GC STANDARD FLOOR TILE AT SERVICE LINE & BOH; CONTACT: REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM GENERAL NOTES A. FINISH MATERIALS VARY ON WALLS. REFER TO INTERIOR ELEVATIONS FOR EXACT FINISHES. B. NO SUBSTITUTIONS ALLOWED ON ANY SPECIFICATIONS. C. REFER TO PSW FURNISHED SAMPLE FOR TROWEL TEXTURE WR01 PRIOR TO APPLYING FINISHED MATERIAL. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM D. REFER TO SHEET A1.2 FOR CEILING HEIGHTS. A R 4 0 4 S. C Wells H I S t ., T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. CONTACT: MICHAEL MONTORSI (630) 539-4470 OR MMONTORSI@M2ILTD.COM DALTILE P-3665 0W81 RED PAVER COVE BASE SKU #0Q81P3365F1PB 4 1/4" X 6" 6" X 6" LATICRETE #45 RAVEN GC WB02 CERAMIC TILE BASE DALTILE ROUND TOP COVE BASE #S-3419T; BLACK K111 SEMI-GLOSS SKU #K111S3419T1P1 WB03 WOOD BASE & SHOE RETAIL FIXTURES CASEWORK ITEM #W306 WITH CASEWORK ITEM #W307 5/8" X 5 1/4" WB04 WOOD BASE RETAIL FIXTURES CASEWORK ITEM #W325 1" x 4" NA VD GC WB05 CERAMIC BASE (BATHROOM) DALTILE COLOUR SCHEME PC36C9TB, UPTOWN TAUPE B904 SKU #B904PC36C9TB1P2 6" X 12" LATICRETE #18 SAUTERNE GC GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM WB06 CERAMIC BASE (CASEWORK) DALTILE VERANDA SOLIDS, GRAVEL P501 SKU #P50165201P 6-1/2" X 20" LATICRETE #45 RAVEN GC GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM WB07 PORCELAIN TILE DALTILE VERANDA SOLIDS, RAWHIDE P525 6-1/2" X 20" LATICRETE #43 CHOCOLATE TRUFFLE GC GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM DALTILE COLOR:GARDEN SPOT #0141; SEMI-GLOSS SKU #014136MOD1P2 3" X 6" LATICRETE #45 RAVEN GC GC CUSTOM ORDER TILE. ALLOW 4 WEEKS. CONTACT: REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM 3" X 6" LATICRETE #45 RAVEN. IF REQ'D BY CODE USE #18 SAUTERNE GC GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM LATICRETE #45 RAVEN WALLS WT01 NOT USED WT02 CERAMIC TILE CERAMIC TILE DALTILE COLOR: BISCUIT K175, SEMI-GLOSS SKU #K17536MOD1P4 2" X 6" LATICRETE #45 RAVEN GC GC BULLNOSE ALONG 6" EDGE; CONTACT: REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM WT04 CERAMIC TILE DALTILE BULLNOSE S-4269; COLOR: BLACK K111, SEMI-GLOSS SKU #K111S42691P2 WT06 CERAMIC TILE DALTILE BLACK QUARTER ROUND A106; COLOR BLACK K111, SEMI-GLOSS SKU #K111A1061P2 3/4" X 6" LATICRETE #45 RAVEN GC GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM WT07 MOSAIC TILE PSW-HUBBARD 1"X1" CUSTOM MOSAIC TILE 1" X 1" TBD PSW GC REFER TO DRAWINGS WT10 CERAMIC TILE (BULLNOSE BACKLINE) DALTILE RITTENHOUSE SQUARE, S-4369, COLOR: BISCUIT K175 SEMI-GLOSS SKU #K175S4369MOD1P2 3" X 6" LATICRETE #18 SAUTERNE GC GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM WT11 GLASS TILE (CHIP CUBBIE) DALTILE ISIS GLASS MOSAICS, CANDY APPLE RES IS19 SKU #IS1911MS1P 1" X 1" (12" X 12" SHEETS) LATICRETE #18 SAUTERNE GC GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM WT12 CERAMIC TILE (CHIP CUBBIE) PSW-HUBBARD CUSTOM MOSAIC TILE TBD TBD VD GC CONTACT ROCKWELL (POTBELLY WAREHOUSE) 312.279.0107 5/8" X 3" LATICRETE #18 SAUTERNE GC GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM WT13 MOSAIC TILE DALTILE FASHION ACCENTS, ILLUMINI LAKE F015 SKU # F015583MS1P WT14 MOSAIC TILE DALTILE FASHION ACCENTS, ILLUMINI LAKE F011 SKU #F0115858MS1P 5/8" X 5/8" LATICRETE #18 SAUTERNE GC GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM WT15 PORCELAIN TILE DALTILE TERRACE, CHERRY P104 SKU #P1046361P 6"X36" LATICRETE #43 CHOCOLATE TRUFFLE GC GC REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): NATIONAL.ACCOUNTS@DALTILE.COM WC01 CUSTOM WALLCOVERING VARIES PSW GC WC02 CUSTOM WALLCOVERING VARIES PSW GC WC03 CUSTOM WALLCOVERING VARIES PSW GC WR01 RANDOM TROWEL TEXTURE GC GC FRP-01 FIBERGLASS REINFORCED PLASTIC PANELS GLASLINER (OR SIMILAR) 1200 SERIES; .090" THICKNESS; COLOR: WHITE TEXTURED 4' X 8' (OR 10') GC GC CL01 ACOUSTIC CEILING TILE ARMSTRONG CLEAN ROOM VL#870- WHITE, WITH 15/16" METAL SUSPENSION GRID 24" X 48" NA GC GC CL06 STAMPED METAL LAY-IN PANEL TIN MAN 12-10 VICTORIAN (LARGE) 24" X 24" NA VD GC CL07 STAMPED METAL LAY-IN PANEL TIN MAN VICTORIAN (SMALL) 24" X 24" NA VD GC ARMSTRONG OR EQUAL 15/16" ALUMINUM SUSPENDED CEILING GRID TO BE PAINTED WITH RUSTOLEUM BRIGHT COAT METALLIC FINISH , ALUMINUM 7715-830 NA GC GC DRYWALL MUD APPLIED TO WALL SURFACE WITH 8" FLAT TROWEL KNIFE. LIGHT STUCCO THICKNESS. USE RANDOM PATTERN TO MATCH PSW SAMPLE ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 REFER TO DRAWINGS FOR HEIGHT. SEAL ALL EDGES & MOULDINGS CEILING PAINTED LAY-IN CEILING GRID SHEET TITLE COUNTERTOPS CN01 SOLID SURFACE CORIAN SAHARA - POLISHED FINISH REFER TO MILLWORK DRAWINGS NA VD GC CN02 GRANITE COUNTERTOPS QUADRO SKU #142855 49" W X 3/4" TH W/ OGEE EDGE NA GC GC CN03 SOLID SURFACE LG MACCHIATO- POLISHED FINISH REFER TO MILLWORK DRAWINGS VD GC FOUND AT HOME DEPOT FINISH SCHEDULE JYOU CL08 CUT COUNTERTOP TO FIT, V.I.F. UNDERMOUNT BOWL SHEET NUMBER PAINTS PT01 PAINT BENJAMIN MOORE NATURA AC-2 BERKSHIRE BEIGE - EGGSHELL FINISH GC GC PT02 PAINT BENJAMIN MOORE NATURA AC-17 SEA PINE - SEMI-GLOSS FINISH GC GC PT03 PAINT BENJAMIN MOORE NATURA 1267 RUBY DUSK - EGGSHELL FINISH GC GC A2.1 3/17/2010 5:34:34 PM WT03 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.1 FINISH SCHEDULE.DWG QUARRY TILE BASE PROJECT NUMBER: 16-059 WB01 BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 BASE PT04 PAINT BENJAMIN MOORE NATURA 944 ALBANY WHITE - EGGSHELL FINISH, SEMI-GLOSS FINISH FOR CEILING GC GC GC GC PT05 PAINT BENJAMIN MOORE NATURA 2160-40 ROASTED SESAME SEED - EGGSHELL FINISH; SEMI-GLOSS IN TOILET ROOMS PT06 PAINT BENJAMIN MOORE NATURA 2174-30 SEDONA CLAY- EGGSHELL FINISH GC GC PT07 PAINT BENJAMIN MOORE NATURA HC-72 BRANCHPORT BROWN - EGGSHELL FINISH GC GC GENERAL NOTES A. FINISH MATERIALS VARY ON WALLS. REFER TO INTERIOR ELEVATIONS FOR EXACT FINISHES. B. NO SUBSTITUTIONS ALLOWED ON ANY SPECIFICATIONS. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM C. REFER TO PSW FURNISHED SAMPLE FOR TROWEL TEXTURE WR01 PRIOR TO APPLYING FINISHED MATERIAL. PT09 PAINT BENJAMIN MOORE NATURA 2144-10 GUACAMOLE - EGGSHELL FINISH GC GC PT10 PAINT BENJAMIN MOORE NATURA 2120-10 JET BLACK - GLOSS - MARINE FINISH GC GC D. REFER TO SHEET A1.2 FOR CEILING HEIGHTS. A R 4 0 4 S. PT11 PAINT BENJAMIN MOORE NATURA HC-32 STANDISH WHITE - GLOSS FINISH GC GC PT12 PAINT BENJAMIN MOORE NATURA HC-49 MAYFLOWER RED- EGGSHELL FINISH GC GC PT13 NOT USED PT14 PAINT BENJAMIN MOORE NATURA E-22 COTTAGE RED - GLOSS FINISH GC GC PT15 PAINT BENJAMIN MOORE NATURA E-43 ESSEX GREEN - ENAMEL ALKYD HIGH GLOSS FINISH AT EXTERIOR; EGGSHELL AT INTERIOR GC GC PT16 PAINT BENJAMIN MOORE NATURA 2165- 20 GOLDEN MEADOW - EGGSHELL FINISH GC GC PT17 PAINT BENJAMIN MOORE NATURA 1307 GERAMUM - EGGSHELL FINISH GC GC PT18 PAINT BENJAMIN MOORE NATURA 2103-20 ENGLISH MANOR- EGGSHELL FINISH GC GC PT19 PAINT BENJAMIN MOORE NATURA AC-3 TEXAS LEATHER - EGGSHELL FINISH GC GC PT20 NOT USED PT21 PAINT BENJAMIN MOORE NATURA 2020-10 BUMBLE BEE YELLOW - SEMI-GLOSS FINISH GC GC SUBMARINE DUCT COLOR PT22 PAINT BENJAMIN MOORE NATURA 2021-50 YELLOW LOTUS - SEMI-GLOSS FINISH GC GC SUBMARINE DUCT COLOR PT23 PAINT BENJAMIN MOORE NATURA 2145-20 TERRAPIN GREEN - SEMI-GLOSS FINISH GC GC SUBMARINE DUCT COLOR PT24 PAINT BENJAMIN MOORE NATURA 2001-10 RUBY RED - SEMI-GLOSS FINISH GC GC SUBMARINE DUCT COLOR PT25 PAINT BENJAMIN MOORE NATURA HC-7 BRYANT GOLD - EGGSHELL FINISH GC GC PT26 PAINT BENJAMIN MOORE NATURA 2145-30 BROOKSIDE MOSS - EGGSHELL FINISH GC GC PT27 PAINT BENJAMIN MOORE NATURA 2062-20 GENTLEMAN'S GRAY - EGGSHELL FINISH GC GC PT28 PAINT BENJAMIN MOORE NATURA HC-158 NEWBURG GREEN - EGGSHELL FINISH GC GC PT29 PAINT BENJAMIN MOORE NATURA HC-136 WATERBURY GREEN - EGGSHELL FINISH GC GC PT30 PAINT BENJAMIN MOORE NATURA 2164-10 SADDLE BROWN - EGGSHELL FINISH GC GC PT31 PAINT BENJAMIN MOORE NATURA 692 - JACK PINE - EGGSHELL FINISH GC GC PT32 PAINT BENJAMIN MOORE NATURA 2118-40 SEA LIFE- EGGSHELL FINISH GC GC PT33 PAINT BENJAMIN MOORE NATURA 2107-10 CHOCOLATE CANDY BROWN - EGGSHELL FINISH GC GC PT34 NOT USED NOT USED GC GC PT35 PAINT BENJAMIN MOORE NATURA 2135-60 SUMMER SHOWER - SEMI-GLOSS FINISH GC GC PT36 PAINT BENJAMIN MOORE NATURA 2158-30 DELIGHTFUL GOLDEN - EGGSHELL FINISH GC GC PT37 PAINT BENJAMIN MOORE NATURA 2175-30 RUST - EGGSHELL FINISH GC GC PT38 PAINT BENJAMIN MOORE NATURA 2154-50 STRAW- SEMI-GLOSS GC GC PT39 PAINT BENJAMIN MOORE NATURA 1672 ALFRESCO- EGGSHELL FINISH GC GC PT40 PAINT BENJAMIN MOORE NATURA 697 SCENIC DRIVE- EGGSHELL FINISH GC GC PT41 PAINT BENJAMIN MOORE NATURA 007 PINATA GC GC PT42 SPECIALITY PAINT SCUFFMASTER AMBIENT DESIGN, COLOR: TB102 (TO MATCH BM2144010) GC GC REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS PT43 SPECIALITY PAINT SCUFFMASTER AMBIENT DESIGN, COLOR: TB101 (TO MATCH BMHC-158) GC GC REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS PT44 SPECIALITY PAINT SCUFFMASTER AMBIENT DESIGN, COLOR: TB099 (TO MATCH BM2107-10) GC GC REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS PT45 NOT USED PT46 PAINT BENJAMIN MOORE NATURA 2062-40 BLUE DAISY - EGGSHELL FINISH GC GC PT47 PAINT BENJAMIN MOORE NATURA 2049-30 TEAL OCEAN - EGGSHELL FINISH GC GC ST01 STAIN SHERWIN WILLIAMS S64WCY6378-4357 GC GC ST02 STAIN SHERWIN WILLIAMS S64WXN1482-4357 GC GC ST03 STAIN SHERWIN WILLIAMS S64WXN12787 GC GC ST04 STAIN SHERWIN WILLIAMS S61WCY6378-4357 GC GC ST05 STAIN MINWAX 50:50 MIX; PROVINCIAL #211 & GOLDEN OAK #210B GC GC ST06 STAIN ZINSSER AMBER SHELLAC; 00701 BULLS EYE GC GC PROVIDE (3) COATS, SANDED BETWEEN. TYPICAL AT CEDAR PANELS & WALL PANELS AS NOTED ON ELEVATIONS. ST07 STAIN MINWAX TINTED POLYURETHANE; PRIME WITH PT-03, THEN (2) COATS POLYSHADES BOMBAY MAHOGHANY - GLOSS FINISH GC GC PROVIDE (3) COATS, SANDED BETWEEN. ST08 STAIN BEHR #501 NATURAL CEDAR GC GC PROVIDE (3) COATS - FOR EXTERIOR USE AT CEDAR PLANKS ST09 STAIN MINWAX MEDIUM RED; 1:1 RATIO OF RED SEDONA #222, JACOBEAN #2750 & (2) COATS AMER SHELLAC GC GC ST10 STAIN SHERWIN WILLIAMS M64F533 TINT GC GC ST11 PAINT BENJAMIN MOORE NATURA PAINT PT-10 GC GC ST12 STAIN MINWAX LIGHT; IPSWICH OR GOLDEN OAK GC GC FURNITURE STAIN ST13 STAIN MINWAX MEDIUM: PROVINCIAL OR MAHOGHANY GC GC FURNITURE STAIN ST14 STAIN MINWAX DARK; SPECIAL WALNUT OR EBONY GC GC FURNITURE STAIN ST-15 STAIN MINWAX DARK; WATER BASED OIL MODIFIED POLYURETHANE - ROYAL WALNUT GC GC ST-16 STAIN MINWAX POLYSHADES BOMBAY MAHOGANY - SATIN FINISH GC GC C Wells H I S t ., T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ALL DOORS AND TRIM UNLESS NOTED OTHERWISE PROJECT NUMBER: 16-059 NOT USED BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 PT08 ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.2 FINISH SCHEDULE (CONT.).DWG STAINS FINISH SCHEDULE (CONT.) JYOU SHEET TITLE BR01 FULL MODULAR BRICK GLEN-GERY BRICK 4-HB MOLDED FACE BRICK - BURGUNDY RANGE (DARK ROSE) SAND TEXTURE GC GC BR02 THIN BRICK GLEN-GERY BRICK ABERDEEN THIN BRICK WITH THIN BRICK CORNERS - BURGUNDY RANGE PAPERCUT TEXTURE GC GC A2.2 10/9/2009 3:17:59 PM SHEET NUMBER BRICK MODEL # Count EQUIPMENT SCHEDULE FURN FINISH INSTALL VOLTS WATTS AMP PLUG COMMENTS E103 SLIDING DOOR ASSEMBLY W/ SHELVES ARDCO CUSTOM SHELVES - (7) FLAT STYLE ON 1" SLOPE W/O DIVIDERS E105 REFRIGERATED FRONT LOAD STATION TRUE TPP-44D-2 W/ S/S BUMPER 1 300 SERIES S/S VD VD 120/1 8.6 5-15P W/ 5" CASTERS. E106 REFRIGERATED DRESS STATION TRUE TSSU-27-12M-C 3 300 SERIES S/S VD VD 120/1 4.9 5-15P W/ 5" CASTERS. E107 REFRIGERATED DRESS/SALAD STATION RANDELL 9412-32D-7 2 S/S VD VD 120/1 5.5 5-15P W/ 2 1/2" CASTERS. E128 37" ICE-CREAM DIPPING CABINET NELSON 6DIP 1 S/S & WHITE ENAMEL VD VD 115V 8 E130 WORKTOP REFRIGERATOR TRUE TUC-27 1 S/S VD VD 115/60/1 3.9 5-15P CONFIRM HINGE SIDE, W/ SHAKE STATION MODIFICATION E201 WALL SHELF ASSEMBLY - 42" METRO (2) 42" W DOUBLE TIER - METROSEAL WALL SHELVES WITH SMARTWALL COMPONENTS 2 GREEN EPOXY VD VD 18" D UPPER SHELF, 14" D LOWER SHELF - SEE ELEVATIONS FOR MOUNTING HEIGHTS. PROVIDE BLOCKING IN WALL. E207 DRY STORAGE SHELVING W/ CASTERS- 48" W FOCUS SHELVES: FF1848G W/ 4 TIERS POSTS: FGN086G 86"H 4 GREEN EPOXY VD VD INCLUDES CASTERS: FSCAST5 1 BLACK EPOXY VD VD REFER TO PLAN FOR ROUGH OPENING DIMENSIONS- SEE VENDOR CUTSHEET FOR INFO 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. E208 MEATBALL WARMER WIRE SHELVING W/ CASTERS FOCUS SHELVES: FF1430C W/ 2 TIERS, (1) S/S FLAT SOLID SHELF POSTS: FGN033C 33"H 1 S/S VD VD E209 SALAD SHELF ELKAY SSP TOP MOUNT SHELF FOR RANDELL UNIT 2 S/S VD VD E210 WRAPPING PAPER SHELF ELKAY 12 1/2" X 27 1/2" SHELF W/ DIVIDER & BRACKETS 3 S/S VD VD E213 STAINLESS STEEL WALL SHELF- 24" ADVANCE TABCO WS-KD-24X 2 S/S VD VD 11 1/8"W X 2' E215 MOBILE DUNNAGE RACK 48" FOCUS FFMDR1848GN 18" X 48" X 13.5 H" 1 GREEN EPOXY VD VD USED AT WALK-IN FREEZER & BREAD BOX STORAGE E219 CHEMICAL SHELF- 14" X 24" FOCUS SHELVES: FF1424G W/ 6 TIERS POSTS: FGN086G 1 GREEN EPOXY VD VD COOLER SHELVING, INCLUDES CASTERS: FSCAST5 E221 WALK-IN WIRE STORAGE SHELF- 18" X 36" FOCUS CAMSHELVING ELEMENTS SERIES 36" - ESK1836V W/ 4 TIERS; POSTS: EPK1872 4 POLYPROPYLENE VD VD COOLER SHELVING, INCLUDES CASTERS: FSCAST5 E222 WALK-IN WIRE STORAGE SHELF- 18" X 42" FOCUS CAMSHELVING ELEMENTS SERIES 42" - ESK1842V W/ 4 TIERS; POSTS: EPK1872 2 POLYPROPYLENE VD VD COOLER SHELVING, INCLUDES CASTERS: FSCAST5 E223 WALK-IN WIRE STORAGE SHELF- 18" X 48" FOCUS CAMSHELVING ELEMENTS SERIES 48" - ESK1848V W/ 4 TIERS; POSTS: EPK1872 1 POLYPROPYLENE VD VD COOLER SHELVING, INCLUDES CASTERS: FSCAST5 E226 OVEN STAND - TURBOCHEF ELKAY CUSTOM - 42" X 31" 2 S/S VD VD TO BE USED WITH E304/E304A E247 DRYING WALL SHELF ASSEMBLY - 42" METRO (2) 42" W DOUBLE TIER - METROSEAL WALL SHELVES WITH SMARTWALL COMPONENTS 2 GREEN EPOXY VD VD AT 3 COMP SINK ONLY. 18" D UPPER SHELF, 14" D LOWER SHELF - SEE ELEVATIONS FOR MOUNTING HEIGHTS. PROVIDE BLOCKING IN WALL. E248 BUN PAN RACK CHANNEL MANUFACTURING 401AC 2 ALUM VD VD E250 MOBILE CART FOCUS 21" x 30" 2 S/S VD VD E251 SUPPORT SHELF FOCUS 21" x 30" 1 SS VD VD E252 DUNNAGE RACK AT SODA 36" FOCUS 24" x 36" FF2436C SHELF, 7" FG007C STATIONARY POSTS 1 SS VD VD E302 MEATBALL WARMER VOLLRATH 72051 1 S/S VD VD 120/1 1600 13.3 5-15P WITH DRAIN E302A MEATBALL WARMER FOR SOUP VOLLRATH 72051 1 S/S VD VD 120/1 1600 13.3 5-15P WITH DRAIN E304 CONVEYER OVEN - HIGH HEAT (REGULAR) TURBOCHEF GLOBAL OPERATIONS HIGH h CONVEYER 2020 2 S/S VD VD 208/240 50 UL 4 PIN PLUG TO BE 60 AMP E401 SLICER BERKEL INC. X13AE 1 VD VD 115/60/1 7 E402 CAN OPENER EDLUND 1S 1 S/S VD VD SECURE TO UNDERSIDE OF TABLE E403 SCALE EDLUND DS SERIES II- DS-10-PB #53300 3 S/S VD PSW 115V AC ADAPTER INCLUDED E404 FAX MACHINE BROTHER MFC-7440N 1 VD VD COORDINATE INSTALL WITH RTG FOR NEW STORES, PSW IT SUPPORT FOR EXISTING STORES E405 SAFE CORPORATE SAFE SPECIALISTS B3121DM 1 VD VD E406 POS RADIANT SYSTEMS P1520 3 VD VD COORDINATE INSTALL WITH RTG FOR NEW STORES, PSW IT SUPPORT FOR EXISTING STORES E409 SODA RACK & CARBONATOR PROFITMASTER DISPLAYS, INC. BIB FLEX RACK SYSTEM, 28" W X 16" D X74" H, ITEM #44239 WITH WALL MOUNT ITEM #44249 1 VD VD BAG IN THE BOX RACK E410 CO2 TANK 1 VD VD GC TO PROVIDE AND INSTALL 4'-0" STRAIGHT LINK CHAIN #4 SIZE AND COMBO PAD LOCK E427 COUNTER MOUNTED BLENDER 2 VD VD ITEM # DESCRIPTION MANUFACTURER FURNITURE SCHEDULE Count FINISH T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. PROVIDE (3) WILDSIDE JARS & (3) RED SPATULAS PER BLENDER MODEL # I ILLINOIS DESIGN FIRM # 184.006688 W/ SLAW TRAY 15 S t ., FURN INSTALL COMMENTS F100 24" X 28" TABLE RETAIL FIXTURE 2 ST-12 VD GC F101 24" X 28" TABLE RETAIL FIXTURE 3 ST-13 VD GC F102 24" X 28" TABLE RETAIL FIXTURE 3 ST-14 VD GC F107 34" X 34" TABLE PSW-HUB 1 CUSTOM PSW-HUB GC F108 28" X 46" TABLE RETAIL FIXTURE 1 ST-12 VD GC F109 28" X 46" TABLE RETAIL FIXTURE 2 ST-13 VD GC F110 28" X 46" TABLE RETAIL FIXTURE 1 ST-14 VD GC F112 24" ROUND TABLE PSW-HUB 2 CUSTOM PSW-HUB GC F113 30" ROUND TABLE PSW-HUB 1 CUSTOM PSW-HUB GC F115 42" ROUND TABLE PSW-HUB 1 CUSTOM PSW-HUB GC F117 STAND UP COUNTER RETAIL FIXTURE 1 ST-13 VD GC F121 OUTDOOR TABLE (WI) - 30" FOUR SEASONS PB-WITABLE-30 6 BLACK WROUGHT IRON VD GC F200 SHORT CAST IRON BASE BARN FURNITURE DRDFDS24 9 BLACK WRINKLE WROUGHT IRON VD GC F201 HIGH BAR BASE - 30" BARN FURNITURE DRDHC3030BH 4 BLACK WRINKLE VD GC STANDARD HIGH BASE- 30 x 30" cross base with bar height column F203 ADA LEGS BARN FURNITURE DRDHC2205 1 BLACK VD GC SET OF 2, TYPICAL AT ADA TABLE F206 HIGH SINGLE PIPE W/ WALL CLEAT RETAIL FIXTURE 3 BLACK VD GC BASE FOR HIGH TOP 28 X 46 OR ALONG WALL F300 CHAIR - INDOOR BARN FURNITURE SCHOOLHOUSE CH3004 17 MEDIUM FINISH VD GC F301 BARSTOOL BARN FURNITURE SCHOOLHOUSE ST3004 30 MEDIUM FINISH VD GC F302 OUTDOOR CHAIR (WI) FOUR SEASONS PB-WICHAIR 12 BLACK WROUGHT IRON VD GC F304 CUSTOM BENCH PSW-HUB 1 CUSTOM PSW-HUB GC F407 OUTDOOR TRASH RECEPTACLE FOUR SEASONS 2 BLACK POWDER COATED VD GC F500 DECORATIVE STOVE CUSTOM POTBELLY HERITAGE ITEM 1 CUSTOM PSW-HUB PSW F501 STANCHION PSW-HUB 3 WROUGHT IRON PSW-HUB GC F502 CHAIN AT STANCHION PSW-HUB 2 METAL PSW-HUB GC SHEET TITLE F503 CUSTOM BUILT SUBMARINE GC 1 PAINT PT21, PT22, PT23, PT24 GC GC FF & E SCHEDULES ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.3 FURNITURE FIXTURE & EQUIPMENT SCHEDULES.DWG A1-48Q-43S SMOOTHER Q15 WILDSIDE CHROME H BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 BLENDTEC HAMMER-TONE INCLUDES: 1430FS, FGN033C & FSCAST5 C Wells SEE PLAN A1.4 FOR LENGTH ALL EXPOSED FASTENERS TO BE PAINTED BLACK JYOU MANUFACTURER SHEET NUMBER A2.3 3/15/2010 2:14:11 PM DESCRIPTION PROJECT NUMBER: 16-059 ITEM # FURN. INSTALL COMMENTS Name DESCRIPTION MANUFACTURER PRODUCT # Count FINISH FURN. INSTALL COMMENTS M103 CUP DISPENSER SAN JAMAR C2410C18 3 VD VD GC M104 MOP/BROOM HANGER CARLISLE 4073100 1 VD VD PSW GC M106 BREAD BIN ELKAY 54"L X 10 1/2"W, SLOPED TOP/OPENING 1 S/S VD VD 48" x 72" PSW GC M107 KNIFE RACK EDLUND KR-700 2 S/S VD VD 36" x 55" PSW GC M109 30" WORK TABLE W/ CASTERS ELKAY 24"D X 30"L 1 S/S VD VD INCLUDES 5" CASTERS 2 PSW GC M111 CORNER GUARD ADE U SHAPE OR L SHAPE - 42"H AT FRP / 57"H AT TILE 3 S/S VD VD INSTALLED PER PSW LOCATIONS ON DWGS HANDICAPPED TOILET ROOM SIGN 2 GC GC M112 COAT RACK EX-CELL 700-SA - 6 HOOK 2 ALUM VD VD PSW 11 X 17 CHALKBOARD SIGN 1 17" X 11" PSW GC M113 PAN RACK NEW AGE 98485 2 ALUM VD VD S212A PSW WALLPAPER "OFFERINGS" PANELS 2 43" x 14" PSW GC LOCATED AT BACKLINE CABINETS M114 CUTTING BOARD / SINK COVER SAN JAMAR 1 WHITE POLY VD VD S213 PSW COMMUNITY BOARD 1 VARIES PSW GC CHOOSE 38"X38" OR 56"X27" M115 CUTTING BOARD - PREP ROOM SAN JAMAR CB182412WH 1 WHITE POLY VD VD PROVIDE POWER AT 96" OR AS INDICATED ON ELECTRICAL DWGS. DESIGN MGR TO SPECIFY VERTICAL (26X43) OR HORIZONTAL (43X26) M121 SLICER SLAW TRAY BERKEL INC. 3875-00241 1 VD VD M123 MEATBALL WARMER PANS VOLLRATH 30043, 30362, 75220 & 75230 4 VD VD PSW PSW GC GC S100 SIGN VENDOR LOGO WALL SIGN 2 S201 PSW SOUP/SHAKE MENU BOARD 1 S202 PSW DESSERT MENU BOARD S203 PSW S204 VD VD 28 1/2"X 31" PSW 1 31"X 56 1/2" MENU BOARD - LARGE 1 PSW MENU BOARD - MEDIUM 1 S207 PSW CLEANING CHECKLIST S208 GC S209 INTERNALLY ILLUMINATED LOCATED IN RESTROOMS S/S S216A PSW YA GOTTA GET IT HOT' SIGN - VERTICAL 1 VARIES PSW GC S218 PSW HANGING 'PHONE AHEAD' ARROW 1 24" X 24" PSW GC M131 GARBAGE TOTE - EXTRA-LARGE RUBBERMAID 9W2700-GY 1 S219 PSW ORDER HERE FINGER SIGN 1 14 1/2" X 35" PSW GC M135 EMPLOYEE LOCKER GLOBAL INDUSTRIES PENCO VANGUARD LOCKER SIX TIER, #WG480954GY 1 M136 COOLER CURTAIN CURTON PRODUCTS M-108-PR-4080 1 VD VD S220 RETAIL FIXTURE HANGING MARKETING SIGN 1 29" X 47" VD GC M138 TICKET RAIL SAN JAMAR CK6536A 1 VD VD S221 PSW OUR SANDWICHES SIGN 1 23 3/4" X 18" PSW GC M141 AUTOMATIC SOAP DISPENSER POWERFOAM PUSH AT HAND SINKS 2 VD VD S222A PSW VINYL STORE HOURS - 24" 2 PSW GC M142 SAFE BASE CORPORATE SAFE SPECIALIST 2820-4 1 VD VD S223 PSW VINYL WINDOW MARKETING MESSAGE 1 PSW GC M143 PAPER TOWEL DISPENSER - AUTOMATIC TORK H1 MATIC SYSTEM 551028A BLACK 4 MOLDED PLASTIC VD VD S224 PSW VINYL SANDWICH MAKERS ONLY SIGN 1 PSW GC M145 4"H BACKSPLASH CUSTOM CUSTOM - 4"HX27"L 18GA. S/S BACKSPLASH 1 S/S VD VD PSW VINYL TOILET ROOM DOOR SIGNS - MEN & WOMEN 2 PSW M146 SINGLE TOPPING STATION DRY PRODUCT DISPSENSER SERVER PRODUCTS 87215 W/ 87217 WALL MOUNT BRACKET, 87199 1/9 SIZE JAR: CLEAR, 87253 HINGE LID: CLEAR, 81516 SERVING SPOON: CLEAR 1 S/S VD VD M147 PUMP RAIL COMBO SERVER PRODUCTS SR-3 82870 W/ 82120 S/S PUMPS AND 82557 JARS 1 SS VD VD M148 CUP & LID ORGANIZER DISPENSE-RITE LID-3BT 2 POLY VD VD M149 STRAW HOLDER DISPENSE-RITE MSH-1 2 ACRYLIC VD VD M150 DRAINER BOARD SSP, INC. CUSTOM - 12"W X 12"D 1 VD VD M151 HANDS FREE SOAP DISPENSER POWERFOAM AUTOMATIC AT TOILET ROOMS 2 BLACK VD VD 3 S/S VD VD S225 CEILING MOUNTED; PROVIDE POWER AT CEILING- FLUSH OUTLET AT TIN CEILING; SPOTLIGHT AT OPEN CEILING GC STEEL, COLOR: GRAY BLACK S300 PSW ORDER YOUR SHAKE NOW SIGN 1 29" X 19" PSW GC S301 PSW PICKLE SIGN 1 9" X 5" PSW PSW S302 PSW EMPLOYEES MUST WASH HANDS SIGN 4 6.5" X 8" PSW GC S303 PSW ADA ASSISTANCE SIGN WITH BELL 1 9" X 11.5" PSW GC S304 PSW NEED ASSISTANCE STROLLER/ADA SIGN 1 12" X 15" PSW GC S305 PSW THANKS FOR YOUR BUSINESS SIGN 1 21" X 27" PSW GC S306 PSW CHIPS PRICE SIGN 1 12" X 1.25" PSW GC M154 DRESS STATION RISER SHELF SPOKANE STAINLESS PRODUCTS S307 PSW COUNTERTOP MARKETING PIPE SIGN 1 22" X 11" PSW PSW M155 BEVERAGE GLIDES ADE CUSTOM MODEL NO. RTC 1 VD VD S308 PSW HOT PEPPERS PRICE SIGN 1 5" X 7" PSW PSW M156 STAINLESS STEEL TABLE 36" ON CASTERS ELKAY FOODSERVICE PRODUCTS WT36S36-BS - 36"D X 36" 1 VD VD S309 PSW HAND SANITIZER STAND AND SIGN 1 9" X 60" PSW GC M200 MIRROR PSW-HUBBARD CUSTOM 2 PSW GC S310 PSW FOUNTAIN CUP/LID HOLDER 1 16.5" X 5.5" PSW PSW M201 3'-6" HORIZONTAL GRAB BAR BOBRICK B-6806 SERIES 2 S/S GC GC S311 PSW LUNCH BOX COOKIE HOLDER 1 6" X 10" X 12" PSW PSW M202 3'-0" HORIZONTAL GRAB BAR BOBRICK B-6806 SERIES 2 S/S GC GC S312 PSW DESSERT RISER 1 18 X 8 X 19 PSW PSW M203 1'-6" VERTICAL GRAB BAR BOBRICK B-6806 SERIES 2 S/S GC GC S313 PSW A-FRAME - EXTERIOR SIGN 1 49"x29" PSW GC M204 DOUBLE ROLL TOILET TISSUE DISPENSER BOBRICK B-2740 2 CHROME VD VD S314 PSW A-FRAME TOPPER 1 24" X 17" PSW GC M205 BABY CHANGING TABLE KOALA KARE KB200 2 CREAM GC GC S315 PSW A-FRAME CHALKBOARDS 1 22.5" X 37" PSW GC M206 COAT HOOK BOBRICK B-6707 2 S/S VD VD S316 PSW P&H CUTTING BOARD 1 17" X 9" PSW GC M207 TRASH CAN 2 CHROME PSW PSW S317 PSW FOUNTAIN DRINK PRICE HOLDER 1 11" X 6.25" PSW GC M209 SANITARY NAPKIN DISPOSAL 1 SS VD VD S318 PSW STOVE PLAQUE 1 9" X 6" PSW GC S319 PSW COFFEE CONDIMENT RISER AND SIGN 1 10.5 X 38 X 22 PSW PSW S320 PSW KIDS MENU 1 13" X 18.5" PSW GC S321 PSW PROMISE SIGN SQUARE 1 28"X28" PSW GC S322 PSW PROMISE SIGN HORIZONTAL 1 32"X18" PSW GC S323 PSW PROMISE SIGN VERTICAL 1 18"X32" PSW GC S324 PSW A WRECK 1 23"x19" framed PSW GC S325 PSW EXTRAS 1 19"x23" framed PSW GC S326 PSW SAVE TIME BEAT THE LINE 1 23"x19" framed PSW GC S327 PSW COOKIES POSTER 1 15"x21" framed PSW GC S328 PSW SHAKES POSTER 1 27"x33" framed PSW GC S329 PSW DELICIOUS SIGN - LARGE 1 8' LONG PSW GC S330 PSW DELICIOUS SIGN - SMALL 1 4' LONG PSW GC S331 PSW PEACE, LOVE & POTBELLY SIGN - LARGE 1 8' LONG PSW GC S332 PSW PEACE, LOVE & POTBELLY SIGN - SMALL 1 4' LONG PSW GC S333 PSW OUR SANDWICHES ARE SO GOOD 1 20" x 11" PSW GC S334 PSW KEEP AMERICA BEAUTIFUL 1 12" x 10" PSW GC S335 PSW GREEN STATEMENT PLAQUE 1 10.5" x 17" PSW GC S336 PSW CHECK OUT OUR DRIVE THRU 1 16" X 20" PSW GC S337 PSW START HERE SIGN 1 8" X 40" PSW GC S338 PSW AMERICAN FLAG 1 60" X 36" PSW GC PLACED OUTSIDE IN FRONT OF STORE- MOVEABLE BOBRICK B-270 INCLUDES S/S BACK PLATE & 14" SKIRT 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. USED WITH ITEM #P204 12X12X 78; 6 OPENINGS. MAY SUBSTITUTE. C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. PLACE ON POTBELLY STOVE W/ PROVIDED CHAIN ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.4 FURNITURE FIXTURE & EQUIPMENT SCHEDULES (CONT.).DWG DIMS.- HxW SHEET TITLE FF & E SCHEDULES (CONT) JYOU Count SHEET NUMBER A2.4 3/15/2010 2:14:44 PM DESCRIPTION PROJECT NUMBER: 16-059 MANUFACTURER MISCELLANEOUS BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 ITEM # SIGNAGE SCHEDULE Count FINISH FURN. INSTALL P102 WATER CLOSET-FLO WISE WITH AUTOMATIC FLUSH AMERICAN STANDARD MADERA FLOWISE 3249.001, ELOGATED BOWL; PROVIDE 6067 HARD WIRED SELECTRONIC FLUSH VALVE (P104) 2 WHITE GC GC P201 THREE COMPARTMENT SINK ELKAY 3C16X20 - 2 - 18X, 20"D X 88"L, 10"H REAR SPLASH, LEFT & RT HAND 18" DRAINBOARDS 1 SS VD GC P204 STAINLESS STEEL WORKTABLE W/ SINK - PREP TABLE ELKAY SLWT30X84BS 1 SS VD P205 MOP SINK W/ FAUCET FIAT MOLDED STONE INTEGRAL DRAIN MSBID2424 W/ 830AA SERVICE FAUCET 1 WHITE P206 FLOOR SINK SIOUX MANUFACTURING 861-23X W/ HALF GRATE 861-52i P208 FLOOR DRAIN SIOUX MANUFACTURING P210 WALL-HUNG LAVATORY AMERICAN STANDARD VOLTS PLUMBING SCHEDULE WATTS AMP PLUG HW. SUPPLY CW. SUPPLY TW. SUPPLY WASTE VENT PROVIDE WITH 5905.100 HEAVY DUTY AMERICAN STANDARD SEAT, FLUSH VALVE #6065.121.002 PROVIDE JBOX IN WALL WITH LOW VOLTAGE POWER. 1" 4" 3/4" 3/4" (3) 2" INDIRECT WASTE, SEE ITEM #P600 FOR FAUCET GC 3/4" 3/4" 1-1/2" PROVIDE FLOOR SINK W/ INDIRECT WASTE CONNECTION. SEE ITEM #P601 FOR FAUCET GC GC 1/2" 1/2" 3" 2" 4 GC GC 3" 2" 842-3-P-NQ 6 GC GC 3" 2" LUCERNE 0355.012 2 VD GC WHITE 2" COMMENTS 1/2" 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM VACUUM BREAKER PROVIDE DEEP SEAL TRAPS, ADD VEGETABLE OR MINERAL OIL TO TRAP SEE ITEM #P611 FOR FAUCET. PROVIDE TEMPERING VALVE. A R 4 0 4 S. HAND SINK ELKAY SEHS-17X - 17"L X 15"W X 5"D W/ SIDE SPLASHES 2 P215 SHAKE STATION (RIGHT HAND VERSION) ELKAY CUSTOM BACK BEVERAGE COUNTER P401 CHEMICAL DISPENSER CHEMICAL DISPENSER P405 HOSE BIB P406 SS VD GC 1/2" 1 VD VD 1/2" PROVIDE TEMPERING VALVE 1629WML/1629WMR 2 VD VD 1/2" CONTAINS ALUMINUM CLORIDE. PROVIDE STAINLESS STEEL DOUBLE CHECK BACKFLOW PREVENTOR WOODFORD #17 1 GC GC TEMPERING VALVE LEONARD 220 4 GC GC P408 BUILT-IN DIPPERWELL T&S BRASS 006678-45 W/ B2282-F03 1 SS VD VD P409 RINSER BLENDTEC JRE-610 LITTLE BLACK RINSER 1 SS VD VD P410 TEA BREWER BUNN TB3Q 1 VD VD P600 3 COMP SINK FAUCET T&S BRASS B-0230-LN FAUCET; 064X 16" SWING NOZZLE W/ STREAM REGULATOR 1 VD GC 1/2" 1/2" P601 PREP TABLE SINK FAUCET T&S BRASS B-0225-LN FAUCET; 135X 12" SWIVEL GOOSENECK 1 VD GC 1/2" 1/2" P603 HAND SINK FAUCET T&S BRASS B-1115-LN FAUCET; 131X SWING GOOSENECK; 1136-45 TEFLON SEAT WASHERS 2 BRONZE VD GC 1/2" 1/2" P605 SPRAYER NOZZLE T&S BRASS B-0133 W/ 063X, B-0155-LNEZ & B-0970-FEZ 1 CHROME VD GC 1/2" P610 SHAKE STATION FAUCET & TEMPERING VALVE T&S BRASS B-0306 1 CHROME VD VD 1/2" P611B LEVER LAVATORY FAUCET-4" SPREAD MOEN 8413SP 2 CHROME VD VD 1/2" P702 WALK-IN COOLER/FREEZER - END DOOR KOLPAK CUSTOM 1 VD GC P704 SODA/ICE DISPENSER CORNELIUS IDC255 1 VD VD 120/60 9.3 3/8" 3/4" P707 ICE MAKER AT SODA MACHINE- AIR-COOLED HOSHIZAKI AMERICA, INC. KML-451MAH 1 VD VD 115/60/1 10.3 1/2" 3/4" P715 COOLER REFRIGERATION SYSTEM - REMOTE COOLER KOLPAK POLAR PAK 1 VD GC 208-230/60/ 1 ALLOWS CONDENSOR TO BE LOCATED ON THE ROOF OR OUTSIDE TO REDUCE HEAT INSIDE STORE; REFRIGERATION HOOK-UP BY EQUIPMENT VENDOR P716 COOLER REFRIGERATION SYSTEM - REMOTE FREEZER KOLPAK POLAR PAK 1 VD GC 208-230/60/ 1 ALLOWS CONDENSOR TO BE LOCATED ON THE ROOF OR OUTSIDE TO REDUCE HEAT INSIDE STORE; REFRIGERATION HOOK-UP BY EQUIPMENT VENDOR P800 GAS WATER HEATER BRADFORD WHITE OR EQUAL EF-60T-199 1 GC GC 120/1 P804 ICE MAKER CONNECTION HOSE DORMONT MANUFACTURING W37B2Q48 1 VD GC P805 LEVER TWIST WASTES T&S BRASS B-3950 2 VD GC P807 WATER HEATER STAND NATIONAL HOT WATER PK101 1 GC GC SS 1/2" 1-1/2" 3/4" 1/2" 120/1/60 1780 14.8 NEMA 5-1SP 1-1/2" SEE ITEM #P603 FOR FAUCET. PROVIDE TEMPERING VALVE. USE FREEZELESS WALL FAUCET MOUNTED AT 32" AFF 1 1/2" FAUCET INCLUDED I S t ., T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. 1/4" PROVIDE TEMPERING VALVE 8" WALL MOUNT FAUCET, ADD-ON FAUCET W/ 8" SWING NOZZLE, CERAMIC CARTRIDGES, COMPACT SPRING & FLEX HOSE, B-0107-C SPRAY VALVE, VACUUM BREAKER & 6" WALL BRACKET & LEVER HANDLES 1/2" USE FOR NEW STORES REFRIGERATION HOOK-UP BY EQUIPMENT VENDOR 1.8 H 1" 1" STANDARD AIR COOLED UNIT REFER TO INSTALLATION GUIDE FOR MORE INFORMATION, EXPANSION TANK TO BE PROVIDED. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 P211 C Wells ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.5 PLUMBING SCHEDULE.DWG MODEL # SHEET TITLE PLUMBING SCHEDULE JYOU MANUFACTURER SHEET NUMBER A2.5 1/13/2010 3:27:21 PM DESCRIPTION PROJECT NUMBER: 16-059 ITEM # MODEL LAMP FURN INSTALL VOLTS WATTS B.O. FIXTURE COMMENTS L100 DECORATIVE PENDANT - 14" CON-TEC SCHOOL HOUSE FIXTURE 11 CM5601150 W/ 8' ASSEMBLY PHILIPS 11A19/END/2700/DIM 6/1 VD GC 120 23 7'-9" AFF TO BOTTOM SEE DETAIL 09/A5.2 L102 ANTIQUE GLOBE FIXTURE CUSTOM BY PSW DECORATIVE CHAIN HUNG FIXTURE WITH VINTAGE COLORED TEXTURE GLASS SHADE 5 CUSTOM PHILIPS EL/MDT2 13W VD GC 120 14 7'-9" AFF TO BOTTOM SEE DETAIL 09/A5.2 L104 WALL SCONCE - TOILET ROOM REJUVENATION SELMA WHITE PORCELEIN 2 A4631 / B2002 SHADE PHILIPS EL/MDT 23W VD GC 120 23 CENTER FIXTURE ABOVE MIRROR AT 7'-0" AFF L107 DECORATIVE PENDANT - 12" REJUVENATION BALDWIN - SINGLE CHAIN PENDANT OIL RUBBED BRONZE W/ 12" OPAL SHADE 4 A3167 / B5937 12" OPAL STEPPED SHADE 23W GU24 LAMP VD GC 120 23 7'-9" AFF TO BOTTOM SEE DETAIL 09/A5.2 L109 CYLINDER PENDANT CON-TECH 6" CYLINDER PENDANT W/ 24" STEM KIT AND MONOPOINT 3 CF6-42P-C-B / CSK24-B / LA18-B PHILIPS PL-T 42W/835/4P/ALTO VD GC 13'-0" AFF TO BOTTOM SEE DETAIL 09/A5.2 L200 CEILING MOUNTED FIXTURE THOMAS LIGHTING 2-LIGHT CEILING MTD, PAINTED BRONZE, 13 1/4" 1 PL869263L 2 (13W) CFQ13/G24q/827 (4 PIN) VD GC 120 26 CEILING MOUNTED L202 CEILING MOUNTED TOILET RM FIXTURE REJUVENATION FRANCIS BLACK PORCELEIN W/ BLACK STRIPED SHADE 2 A7685 / B1489 BLACK STRIPED SHADE 23W GU24 LAMP VD GC 120 23 N/A L203 SURFACE MOUNT COOLER STRIP LIGHT METALUX VAPORITE 1 X4 STRIP LIGHT (2) LAMP 1 VT-232-120-EB81 GE F28T8/SP35/UMX/ECO; ORDER CODE: 00256 GC TO PROVIDE LAMPS VD/GC GC 120 L207 LED TRACK HEAD (MENU) CON-TEC PAR30 ROUND BACK CYLINDER TRACK HEAD 8 CTL230-B SOLAIS LR30LN/25/30K/18W/1000/BK VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A5.2 L208 LED TRACK HEAD (WALL FLOOD) CON-TEC PAR30 ROUND BACK CYLINDER TRACK HEAD 23 CTL230-B SOLAIS LR30LN/40/30K/18W/1000/BK VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A5.2 L210 LINEAR TRACK FIXTURE 48" CON-TEC LINEAR SLIM STYLE WALLWASH 3 CTL14154/HO-B PHILIPS F54T5/835/HO/ALTO VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 13'-6" AFF SEE DETAIL 12/A5.2 L302 RECESSED 2 X 4 COOPER METALUX, 2X4, 3 LAMP FLUORESCENT FIXTURE 5 METALUX 2GR8-332A-UNV-EB81-U, 2X4 RECESSED (3) PHILIPS LED T8 LAMPS; PRODUCT NO: 45359-7; ORDERING CODE: 12T8/48-3500 IF 10/1 VD GC L305 RECESSED 2 X 2 COOPER METALUX, 2X2, 2 LAMP FLUORESCENT FIXTURE 1 2GC8-317A-UNV-EB81-U (3) F17T8/SP35/ ITEM #45743 VD GC L310 6" RECESSED DOWNLIGHT (LED) CON-TEC 6" INCADESCENT HOUSING AND TRIM 2 RL38 + CTR1902-WHT SOLAIS LR38/25/30K/1025BK VD GC L311 6" RECESSED DOWNLIGHT W/ WALLWASH (LED) CON-TEC 6" INCADESCENT HOUSING AND WALLWASH TRIM 1 RL38 + CTR3807-WHT LR38/25/30K/1025BK VD GC L500 EMERGENCY LIGHT TECHNICAL CONSUMER PRODUCTS EMERGENCY LIGHT TCP 20760 Emergency 7 20760 EMERGENCY HALOGEN LIGHTS VD GC L502 EMERGENCY EXIT SIGN W/ LIGHTS TECHNICAL CONSUMER PRODUCTS COMBO EMERGENCY EXIT SIGN W/ (2) HEADS 4 TCP 20723 VD GC L601 WALL MOUNTED SPEAKER SOUNDTUBE WALL MOUNT SPEAKER 2 SM400I VD VD GC TO INSTALL BACKER BOX FOR SPEAKERS L602 CEILING MOUNTED SPEAKER LOWELL 8" DUAL CONE SPEAKER ASSEMBLY 3 R SERIES VD VD GC TO INSTALL BACKER BOX FOR SPEAKERS L610 72" EXTENSION ROD REVOLUTION LIGHTING 72" IRON DOWN ROD - DR72VB 2 DR72VB VD GC FOR USE WITH L400 CEILING FAN. L611 LAMP CHANGER KIT MR. LONGARM INC. LAMP CHANGER KIT 1 B8601 3030 VD GC L613 3' X 5' EXHAUST HOOD JD HIGGINS SS HOOD W/ 18" ENCLOSURE PANEL 2 3624 VD GC L614 4'-0" BLACK TRACK CON-TECH 4'-0" BLACK TRACK FOR LED TRACK HEADS 2 LT-4-B VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A5.2 L615 6'-0" BLACK TRACK CON-TECH 6'-0" BLACK TRACK FOR LED TRACK HEADS 12 LT-6-B VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A5.2 L617 TRACK END FEED CON-TECH END FEED (ONE NEEDED FOR EACH TRACK) 9 LA-10-B VD GC L618 TRACK CONNECTOR CON-TECH CONNECTOR TO FIT MULTIPLE TRACKS TOGETHER 4 LA-2-B VD GC L619 TRACK CORNER CONNECTOR CON-TECH CONNECTOR TO FIT TRACKS AT A 90 ANGLE 1 LA-12-B VD GC L620 CURRENT LIMITING DEVICE CON-TECH CURRENT LIMITING POER FEED 5 LA-23-RN VD GC 120 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM FIXTURE BY VENDOR, LAMPS BY GC A R 4 0 4 S. C Wells H I S t ., T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. 6 WILL NOT BE USED IN ALL LOCATIONS. VERIFY WITH ENGINEERING DRAWINGS ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.6 LIGHTING SCHEDULE.DWG Count SHEET TITLE LIGHTING SCHEDULE JYOU DESCRIPTION SHEET NUMBER A2.6 3/17/2010 5:39:48 PM MANUFACTURER PROJECT NUMBER: 16-059 TYPE BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 ITEM # LIGHTING SCHEDULE ITEM # DESCRIPTION MANUFACTURER MODEL # SPECIFICATION FURN FINISH INSTALL A100 SHROUD SUPPORT - END, 18" H CR LAURENCE (RETAIL) SBPP08EBS CRL BRUSHED STAINLESS 18" x 1" SBPP08 SLIMLINE SERIES ROUND END PARTITION POST A101 SHROUD SUPPORT - MIDDLE, 18" H CR LAURENCE (RETAIL) SBPP08CBS CRL BRUSHED STAINLESS 18" x 1" SBPP08 SLIMLINE SERIES ROUND END PARTITION POST STAINLESS STEEL VD GC A102 SHROUD SUPPORT - ANGLE (90), 18" H CR LAURENCE (RETAIL) SBPP08LBS CRL BRUSHED STAINLESS 18" x 1" SBPP08 SLIMLINE SERIES ROUND END PARTITION POST STAINLESS STEEL VD GC A103 CHALK BOARD PANEL RETAIL FIXTURE STAINLESS STEEL VD GC A104 2" STAINLESS STEEL SUPPORT LEG RETAIL FIXTURE WOOD SUBSTRATE WITH CHALKBOARD PAINT VD GC A105 WALL CLEAT (COUNTER TOP SUPPORT) RETAIL FIXTURE STAINLESS STEEL VD GC A106 WOOD CHIP CUBBIE BASKET RETAIL FIXTURE WOOD VD GC A107 POS SHROUDS RETAIL FIXTURE SOLID SURFACE VD GC STAINLESS STEEL VD GC COMMENTS 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 C116 SODA/ICE MACHINE SHROUD RETAIL FIXTURE PBSFC 68" HIGH - 3/4" PLYWOOD WITH METAL SCREENING PANEL - OUTWATER #RC60 C117 SODA/ICE MACHINE SHROUD (TX ONLY) RETAIL FIXTURE PBSFC-TX 78" HIGH - 3/4" PLYWOOD WITH METAL SCREENING PANEL - OUTWATER #RC60 STAIN: ST03; METAL PANEL: DAKOTA BLACK VD GC STAIN: ST03; METAL PANEL: DAKOTA BLACK VD GC TO BE USED AT TEXAS STORES ONLY C119 DT ASSEMBLY COUNTER RETAIL FIXTURE CUSTOM SOLID SURFACE COUNTER TOP (CN03) VD GC C120 DT SODA COUNTER RETAIL FIXTURE CUSTOM SOLID SURFACE COUNTER TOP (CN03) VD GC THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. DRIVE-THU LOCATIONS ONLY DRIVE-THU LOCATIONS ONLY C122 MANAGER'S DESK RETAIL FIXTURE PBMDSK ALMONDINE MELAMINE VD GC ESPRESSO FINISH GC GC RESTROOM WALL CABINET HOME DEPOT (OR EQUAL) TREW2428 FOREMOST HAVEN WALL CABINET WITH 2 DOORS, 2 ADJ. SHELVES & POLISHED CHROME KNOBS MAY SUBSTITUTE FOR EQUAL SPECIFICATION. GC TO PROVIDE KEY AND LOCK. STEEL FRAME - 2X2 18GA. SQUARE TUBING, WELDED CONSTRUCTION, SMOOTH GRIND ALL EXPOSED WELDS; LEGS - 1/4X2O STAINLESS STEEL LEGS W/ LEVELERS; SIDE PANELS - 3/4" BALTIC BIRCH/MELAMINE ATTACHED TO STEEL FRAME; COUNTER: CORIAN OVER PLYWOOD STEEL FRAME: BLACK POWDER COAT; COUNTER: CORIAN -CN01; DOORS: ST03; SIDE PANELS: ST-03; INTERIOR: ALMOND MELAMINE VD GC C131 LARGE SODA CABINET (P-LAM) RETAIL FIXTURE C132 SODA/ICE MACHINE SHROUD (P-LAM) RETAIL FIXTURE PBSFC 68" HIGH - 3/4" PLYWOOD WITH METAL SCREENING PANEL - OUTWATER #RC60 STAIN: ST03; METAL PANEL: DAKOTA BLACK VD GC C133 SODA/ICE MACHINE SHROUD (TX ONLY) (P-LAM) RETAIL FIXTURE PBSFC-TX 78" HIGH - 3/4" PLYWOOD WITH METAL SCREENING PANEL - OUTWATER #RC60 STAIN: ST03; METAL PANEL: DAKOTA BLACK VD GC C134 TRASH - LARGE (PLAM) RETAIL FIXTURE PBLT PLASTIC LAMINATE VERSION, CN-01 TOP VD GC C135 TRASH - SMALL (PLAM) RETAIL FIXTURE PBST PLASTIC LAMINATE VERSION, CN-01 TOP VD GC C136 TRASH- SLIM JIM (PLAM) RETAIL FIXTURE PLASTIC LAMINATE VERSION, CN-01 TOP VD GC TO BE USED AT TEXAS STORES ONLY PROJECT NUMBER: 16-059 C123 BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 3/4" MELAMINE ISSUE DATE SM SODA CABINET (P-LAM) RETAIL FIXTURE VD GC C139 LARGE SODA CABINET W/ BIB RACK BELOW (P-LAM) RETAIL FIXTURE VD GC C140 SM SODA CABINET W/ BIB RACK BELOW (P-LAM) RETAIL FIXTURE VD GC C200 ADA COUNTER FRONT PANEL RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (35-3/4"" W - VERIFY WITH SHOP DRAWINGS) STAIN: ST03 VD GC C201 ORDER COUNTER FRONT PANEL RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (41-3/4" W - VERIFY WITH SHOP DRAWINGS) STAIN: ST03 VD GC STAIN: ST03 VD GC STAIN: ST03 VD GC C202 CHIP CUBBIE (7 BAYS WIDE, 3 HIGH) RETAIL FIXTURE CUSTOM CABINET - 3/4" BIRCH PLYWOOD SIDES AND INNER BACK, 3/4" SQ SOLID WOOD EDGING, MELAMINE BACK PANEL; COUNTER - 3/4" BIRCH PLYWOOD OVER 3/4" PLYWOOD SUBSTRATE W/ 3/4" BIRCH DROP EDGE C203 DRESS COUNTER FRONT PANEL RETAIL FIXTURE CUSTOM WOOD PANEL (SIZE VARIES - VERIFY WITH SHOP DRAWINGS) ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.7 CASEWORK SCHEDULE.DWG C138 C204 POS FRONT PANEL RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (94-3/4" W - VERIFY WITH SHOP DRAWINGS) STAIN: VARIES VD GC C205 POS SIDE PANEL RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (46" W - VERIFY WITH SHOP DRAWINGS) STAIN: VARIES VD GC C206 END WALL HIGH PANEL RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (36" W - VERIFY WITH SHOP DRAWINGS) C207 POS HIGH PANEL FRONT - DRIVE THRU RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (51-1/4" W - VERIFY WITH SHOP DRAWINGS) STAIN: VARIES VD GC C208 POS HIGH PANEL SIDE - DRIVE THRU RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (46" W - VERIFY WITH SHOP DRAWINGS) STAIN: VARIES VD GC C209 ORDER/LOAD FRONT PANEL RETAIL FIXTURE CUSTOM CUSTOM WOOD PANEL (47 3/4"" W - VERIFY WITH SHOP DRAWINGS) STAIN: VARIES VD GC CASEWORK SCHEDULE JYOU SHEET TITLE A2.7 9/29/2009 10:05:16 AM SHEET NUMBER MANUFACTURER MODEL # SPECIFICATION FURN FINISH INSTALL C300 ADA COUNTER RETAIL FIXTURE CUSTOM SOLID SURFACE COUNTER TOP MACCHIATO- POLISHED FINISH VD GC C301 ORDER COUNTER TOP CAP RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC C302 NOT USED C303 DRESS COUNTER TOP CAP RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC MACCHIATO- POLISHED FINISH VD GC COMMENTS 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. POS COUNTER RETAIL FIXTURE CUSTOM SOLID SURFACE COUNTER TOP MACCHIATO- POLISHED FINISH VD GC RETAIL FIXTURE CUSTOM SOLID SURFACE COUNTER TOP MACCHIATO- POLISHED FINISH VD GC C305 POS COUNTER TOP CAP (SIDE) RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC C306 END WALL TOP CAP RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC C307 POS DT HIGH WALL TOP CAP (FRONT) RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC C308 POS DT HIGH WALL TOP CAP (SIDE) RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC C309 ORDER/LOAD TOP CAP RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP - 9" MACCHIATO- POLISHED FINISH VD GC C310 DT WINDOW TOP CAP RETAIL FIXTURE CUSTOM SOLID SURFACE TOP CAP -CUSTOM SIZE PBSDW SIDES/BACK/BOTTOM - 3/4 BIRCH PLYWOOD; BACKSPLASH - 3/4" MAPLE TRIM; FACE FRAME - 3/4" X 2" MAPLE TRIM; CORNER TRIM - 1X1 TRIM; PULLS - ROUND FLUSH PULL STAIN ALL: ST04; PULLS: DARK BRONZE VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL PBUNG SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE FRAME - 3/4" X 2" MAPLE; SHELVES - (3) 3/4" PLYWOOD W/ MAPLE DROPPED EDGE; DOORS - 3/4" X 2-1/4" 1/4" SIDES/TOP/BOTTOM: ST11; BACK/SHELVES: ST02 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8” x 43 1/4" (VISIBLE AREA 13-7/8” x 27-3/4”) PBUNG SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE FRAME - 3/4" X 2" MAPLE; SHELVES - (3) 3/4" PLYWOOD W/ MAPLE DROPPED EDGE; DOORS - 3/4" X 2-1/4" POPLAR W/ WOOD PANEL INSERTS SIDES/TOP/BOTTOM: ST11; BACK/SHELVES: ST02 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8” x 43 1/4" (VISIBLE AREA 13-7/8” x 27-3/4”) V201 BACKLINE WALL CABINET - OPEN RETAIL FIXTURE RETAIL FIXTURE V202 BACKLINE WALL CABINET - WOOD RETAIL FIXTURE V203 BACKLINE SHELVING RETAIL FIXTURE 3/4" BIRCH PLYWOOD (3) W/ MAPLE D.E. ST01 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL V204 BACKLINE WALL CABINET - OPEN 40" RETAIL FIXTURE PBUNG SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE FRAME - 3/4" X 2" MAPLE; SHELVES - (3) 3/4" PLYWOOD W/ MAPLE DROPPED EDGE; DOORS - 3/4" X 2-1/4" 1/4" SIDES/TOP/BOTTOM: ST11; BACK/SHELVES: ST02 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8” x 28 1/4" (VISIBLE AREA 13-7/8” x 27-3/4”) V205 BACKLINE WALL CABINET - WOOD 40" PBUNG SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE FRAME - 3/4" X 2" MAPLE; SHELVES - (3) 3/4" PLYWOOD W/ MAPLE DROPPED EDGE; DOORS - 3/4" X 2-1/4" POPLAR W/ WOOD PANEL INSERTS SIDES/TOP/BOTTOM: ST11; BACK/SHELVES: ST02 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8” x 28 1/4" (VISIBLE AREA 13-7/8” x 27-3/4”) PBUNG SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE FRAME - 3/4" X 2" MAPLE; SHELVES - (3) 3/4" PLYWOOD W/ MAPLE DROPPED EDGE; DOORS - 3/4" X 2-1/4" 1/4" SIDES/TOP/BOTTOM: ST11; BACK/SHELVES: ST02 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8” x 18-1/4” (VISIBLE AREA 13-7/8” x 17-3/4”) PBUNG SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE FRAME - 3/4" X 2" MAPLE; SHELVES - (3) 3/4" PLYWOOD W/ MAPLE DROPPED EDGE; DOORS - 3/4" X 2-1/4" POPLAR W/ WOOD PANEL INSERTS SIDES/TOP/BOTTOM: ST11; BACK/SHELVES: ST02 VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8” x 18-1/4” (VISIBLE AREA 13-7/8” x 17-3/4”) RETAIL FIXTURE V206 BACKLINE WALL CABINET - OPEN 30" V207 BACKLINE WALL CABINET - WOOD 30" RETAIL FIXTURE V208 MENU HOLDER RETAIL FIXTURE VD GC LOCATE AS PER PLAN OR PSW DIRECTION V209 TRAY HOLDER RETAIL FIXTURE VD GC ATTACH TO SIDE OF TRASH CABINETS V210 BACKLINE WALL CABINET (PLAM) RETAIL FIXTURE PBUNG PLASTIC LAMINATE VERSION VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL V211 ICE CREAM WALL CABINET (PLAM) RETAIL FIXTURE PBSDW PLASTIC LAMINATE VERSION VD GC PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL W300 DECORATIVE DOOR CASING RETAIL FIXTURE POPLAR STAINED BY RETAIL FIXTURE: ST-03 VD GC AT ALL DOORS UNLESS NOTED OTHERWISE W301 CORNER TRIM RETAIL FIXTURE 1" X 1" SOLID POPLAR CORNER TRIM (8' AT CEDAR, 4' AT BEADBOARD) VARIES: GC TO STAIN ST-06 AT CEDAR / GC TO PAINT: PT-04 AT BEAD BOARD VD GC W302 TOP CAP RETAIL FIXTURE 1" X 3" SOLID POPLAR TOP CAP STAINED BY RETAIL FIXTURE: ST-01 VD GC INSTALL WITH POPLAR QUARTER ROUND W303 CEDAR PLANKS - INTERIOR RETAIL FIXTURE 1" X 6" TONGUE AND GROOVE CEDAR PLANKS GC TO STAIN: ST-06 VD GC 6" W PLANKS. INSTALL 1X3 WOOD CAP WITH QUARTER ROUND TRIM PIECE AT TOP, SMOOTH SIDE TO FACE OUT W304 BEADBOARD PANELING RETAIL FIXTURE GEORGIA PACIFIC SANDED 1 1/2" O.C. BEAD PATTERN STAINED BY RETAIL FIXTURE: ST-10 VD GC 4' X 8' X 11/32" PANELS W305 CHAIR RAIL RETAIL FIXTURE POPLAR GC TO PAINT: PT-04 VD GC AT TOP OF BEAD BOARD W306 QUARTER ROUND TRIM RETAIL FIXTURE POPLAR (AT CEDAR ONLY) GC TO STAIN ST-06 VD GC AT ALL WOOD BASE AND SERVICE LINE W309 WOOD APRON/ WALLTRIM/ DOOR JAMB RETAIL FIXTURE 1" X 6" POPLAR STAINED BY RETAIL FIXTURES: VARIES (SOFFIT TRIM: ST-04 / WALL TRIM ST-03) VD GC AT ALL WINDOWS AS NOTED IN ELEVATIONS W310 WOOD SILL RETAIL FIXTURE POPLAR STAINED BY RETAIL FIXTURES: ST-03 VD GC AT ALL WINDOWS AS NOTED IN ELEVATIONS W312 STANDING TRIM - STAINED RETAIL FIXTURE 1" X 2" POPLAR TRIM STAINED BY RETAIL FIXTURES; REFER TO INTERIOR ELEVATIONS FOR MORE INFORMATION VD GC REFER TO ELEVATIONS W312A STANDING TRIM - PAINTED RETAIL FIXTURE 1" X 2" POPLAR TRIM PAINTED BY GC; REFER TO INTERIOR ELEVATIONS FOR MORE INFORMATION VD GC REFER TO ELEVATIONS VD GC AT TOP OF DOOR HEADS AS NOTED IN ELEVATIONS VD GC RETAIL FIXTURE W313 TRIM CAP RETAIL FIXTURE 2" X 2" SOLID POPLAR STAINED BY RETAIL FIXTURES: VARIES (SOFFIT TRIM: ST-04 / WALL TRIM ST-03) W314 PLINTH BLOCK AT COOLER TRIM RETAIL FIXTURE 1-3/4" X 7-3/4" X 10" POPLAR PLINTH BLOCK STAINED BY RETAIL FIXTURES: ST-03 I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. POS COUNTER ICE CREAM WALL CABINET S t ., ILLINOIS DESIGN FIRM # 184.006688 C304A V200 H BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 C304 C Wells ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.8 CASEWORK SCHEDULE (CONT.).DWG DESCRIPTION PROJECT NUMBER: 16-059 ITEM # CEDAR TOP CAP GC 2" X 8" CEDAR TOP CAP GC TO STAIN: ST-06 GC GC AT TOP OF PARTIAL HEIGHT WALL AND SILL AT COOLER W316 ROSETTE BLOCK (AT COOLER TRIM) RETAIL FIXTURE 1" X 7-3/4" X 7-3/4" TH. BULL'S EYE BLOCK WITH ROSETTE CARVING STAINED BY RETAIL FIXTURES: ST-03 VD GC AT COOLER TRIM W317 PLYWOOD PANELS GEORGIA PACIFIC GRADE "B" SMOOTH FINISH GC TO STAIN: ST-06 GC GC 4' X 8' LUAN PLYWOOD PANELS, SMOOTH ON ONE SIDE. GLUE AND INSTALL TRIM AND NAILS W318 FLAT DOOR CASING RETAIL FIXTURE 1" X 3 1/2" POPLAR TRIM WITH MITERED CORNER STAINED BY RETAIL FIXTURES: ST-03 VD GC DOOR TRIM IN BACK OF HOUSE AS NOTED IN ELEVATIONS CASEWORK SCHEDULE SHEET NUMBER A2.8 9/29/2009 10:05:16 AM W315 JYOU SHEET TITLE SPECIFICATION FINISH FURN INSTALL COMMENTS W319 COOLER TRIM BACK BAND RETAIL FIXTURE POPLAR STAINED BY RETAIL FIXTURES: ST-03 VD GC INSTALL AROUND COOLER OPENING AS NOTED ON ELEVATIONS W320 COOLER APRON PACKAGE PSW - HUB WOOD FRAMED CUSTOM MOSAIC TILE PANEL STAINED BY PSW-HUB PSW-HUB GC INSTALL AT APRON OF COOLER AS NOTED ON ELEVATIONS. COORDINATE DIMENSIONS WITH PSW REP W321 POLE WRAP TAMBOUR POLE WRAP 8' HIGH - VARIOUS LENGTHS AVAILABLE (12", 16" OR 48") REFER TO ELEVATIONS GC GC AVAILABLE AT HOME DEPOT AND LOWES RETAIL FIXTURE COLUMN - CLEAR PINE SMOOTH COLUMN AND ENDS; BACK PANEL - 3/8" BEADBOARD BACK; TOP/BOTTOM/SIDES/SHELVES - 1-1/2" CONSTRUCTION GRADE LUMBER, PANEL INSERTS - 3/4" PLYWOOD STAINED BY RETAIL FIXTURES: ST-01 VD GC PROVIDE ELECTRICAL AS REQUIRED W322 BOOKCASE 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. 6" CEDAR PLANKS - EXTERIOR GC 6" ROUGH SEWN CEDAR PLANKS GC TO STAIN: ST-08 GC H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 GC W324 4" CEDAR PLANKS - EXTERIOR GC 4" ROUGH SEWN CEDAR PLANKS GC TO STAIN: ST-08 GC GC W325 4" BEVEL BASE RETAIL FIXTURE 1"X4" POPLAR WITH BEVEL EDGE STAINED BY RETAIL FIXTURES: ST-03 GC GC AT ALL WOOD BASE W326 4" CHAIR RAIL RETAIL FIXTURE 1"X4" POPLAR STAINED BY RETAIL FIXTURES: ST-03 GC GC AT ALL WOOD CHAIR RAIL ADL2 4 X 4 CEDAR POSTS GC 4" X 4" X 9' H CEDAR POSTS STAIN: ST-06 GC GC BACK POSTS AT PLATFORM ADL3 6 X 6 DECORATIVE POSTS RETAIL FIXTURE 6" X 6" X 9' H DECORATIVE POST PAINT PT-11 OR STAIN:ST-10 VD GC FRONT POST AT PLATFORM ADL5 PICTURE FRAME RETAIL FIXTURE 1" X 2" FLAT WOOD TRIM PAINTED BY GC; REFER TO INTERIOR ELEVATIONS FOR MORE INFORMATION VD GC REFER TO ELEVATIONS ADL6 DECORATIVE WOOD PANELS GC 18" W WOOD BI-FOLD DOOR PAINT: PT-01 GC GC REFER TO ELEVATIONS ADL7 PLATFORM ABOVE BOOTH GC GC GC REFER TO ELEVATIONS THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 W323 C Wells ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.9 CASEWORK SCHEDULE (CONT.).DWG MODEL # SHEET TITLE CASEWORK SCHEDULE JYOU MANUFACTURER SHEET NUMBER A2.9 9/29/2009 10:05:16 AM DESCRIPTION PROJECT NUMBER: 16-059 ITEM # KEY NOTES S223 S222A 10 S209 4 2 3 8 8 6 6 9 7 30'-2" VIF PSW SPACE 01 EXISTING SOUTH ELEVATION SCALE: 3/16" = 1'-0" EXISTING NORTH ELEVATION 02 SCALE: 3/16" = 1'-0" 2 EXISTING STOREFRONT 3 EXISTING AWNING 4 EXISTING FRONT ENTRY 5 EXISTING SIDE ENTRY 6 EXISTING SCONCES 7 BRICK 8 EIFS 9 REAR DOOR 10 VINYL LOGO & STORE HOURS ON DOOR 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. C H Wells S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. PROJECT NUMBER: 16-059 7 1 INTERNALLY ILLUMINATED WALL SIGN BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 3 1 1 ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 1 8 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A3.0 EXTERIOR ELEVATIONS.DWG 7 6 3 5 3 2 6 3 2 EXTERIOR ELEVATIONS 7 JYOU SHEET TITLE 03 EXISTING EAST ELEVATION SCALE: 3/16" = 1'-0" A3.0 12/21/2009 4:27:39 PM SHEET NUMBER KEY NOTES PT-37 PT-37 31 PT-19 W312 5 SWINGING SERVICE DOOR. 6 DOOR TRIM, REFER TO DETAIL 01/A2.0. 7 VINYL MARKETING MESSAGE ON WINDOW. 8 PROVIDE BLOCKING IN WALL 9 COOLER OPENING WITH TRIM SURROUND. REFER TO DETAIL 04/A5.0 . 10 1x2 WOOD TRIM. 11 CEDAR TONGUE AND GROOVE PANELS. 12 BEADBOARD PANELS. 13 CUSTOM WALLPAPER. 14 SODA CABINET. REFER TO MILLWORK AND PLUMBING SHEETS. 4'-4" T.O. WALL 15 4'-0" T.O. DOOR 16 BACK BOARD CABINET-LOWEST SHELF TO BE 6" D. SERVICE LINE CABINETRY. REFER TO CASEWORK SHEET FOR INFORMATION. 26 16'-0" B.O. DECK L.P. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A 13'-0" T.O. TRIM PT-47 WR01 28 W305 PT-04 4'-0" T.O. TRIM 12 W304 0'-0" B.O. FIN. FLR WB-04 2 01 1 18 4 S222A 42 S209 43 S223 7 2 SCALE: 3/8"=1'-0" WR01 8 S221 45 8 S201 02 ENTRY FROM SERVICE TO DINING PT-19 SCALE: 3/8"=1'-0" PT-19 8 2'-2" 35 27 SMALL TRASH CAN. 18 LARGE TRASH CAN. 19 BOOTH SEATING. 20 BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 21 DISPLAY PLATFORM ABOVE. 22 PARTIAL HEIGHT WALL AT QUEUING LINE. 23 END WALL AT SERVICE LINE. GC TO PROVIDE 5 8" DUROCK AT MILLWORK WALL TO RECEIVE TILE. 24 4X4 CEDAR POSTS AT BACK OF PLATFORM 25 CUSTOM POSTS AT FRONT OF PLATFORM, COORD WITH PSW REP. 26 STANDING TRIM 27 1X6 END TRIM 28 CHAIR RAIL. 29 CORNER MOULDING, TYPICAL AT ALL EXPOSED CORNERS. 30 SUBMARINE DUCT WITH ROTATING PROPELLER, REFER TO DETAIL 13/A5.2. 31 HVAC DUCT, PAINTED PT-19. REFER TO MECHANICAL SHEETS FOR INFORMATION. 32 MECHANICAL HOOD AT OVENS. 33 HANGING MARKETING SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. "YA GOTTA GET IT HOT" SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 1 ELEVATION AT ENTRY 44 17 S216A 8 34 W309 YA GOTTA GET IT 13 PT-02 28 PT-04 34 WC-01 W305 W305 W303 11 WT-02 W319 03 ELEVATION AT SERVICE/DINING 35 SOUP/SHAKE MENU BOARD. 36 SANDWICH MENU BOARD. 37 DESSERT MENU BOARD. 38 DECORATIVE TILE PANEL AT COOLER APRON 39 PAPER TOWEL DISPENSER 40 SOAP DISPENSER 41 WALL MOUTED SERVICE SINK 42 VINYL STORE LOGO AND HOURS 43 11X17 CHALKBOARD SIGN 44 OUR SANDWICHES SIGN 45 ORDER HERE FINGER 46 SOLID SURFACE COUNTER TOP AND TOP CAP. OPEN 9 SCALE: 3/8"=1'-0" 04 ENTRY FROM DINING/SERVICE SCALE: 3/8"=1'-0" R 4 0 4 S. C H Wells S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A4.0 INTERIOR ELEVATIONS.DWG 4 INTERIOR ILLUMINATED WINDOW SIGNAGE. PROVIDE POWER. REFER TO ELECTRICAL DRAWINGS. ENTRY DOORS. 3 SHEET TITLE INTERIOR ELEVATIONS JYOU EXISTING COLUMN. SHEET NUMBER A4.0 12/21/2009 4:28:08 PM 2 PROJECT NUMBER: 16-059 EXISTING STOREFRONT SYSTEM TO REMAIN. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 1 KEY NOTES PT-19 WR01 PT-37 PT-19 WR01 INTERIOR ILLUMINATED WINDOW SIGNAGE. PROVIDE POWER. REFER TO ELECTRICAL DRAWINGS. PT-37 4 ENTRY DOORS. 5 SWINGING SERVICE DOOR. 6 DOOR TRIM, REFER TO DETAIL 01/A2.0. 7 VINYL MARKETING MESSAGE ON WINDOW. 8 PROVIDE BLOCKING IN WALL 9 COOLER OPENING WITH TRIM SURROUND. REFER TO DETAIL 04/A5.0 . 10 1x2 WOOD TRIM. 11 CEDAR TONGUE AND GROOVE PANELS. 12 BEADBOARD PANELS. 13 CUSTOM WALLPAPER. PT-04 14 SODA CABINET. REFER TO MILLWORK AND PLUMBING SHEETS. 4'-0" T.O. TRIM 15 BACK BOARD CABINET-LOWEST SHELF TO BE 6" D. SERVICE LINE CABINETRY. REFER TO CASEWORK SHEET FOR INFORMATION. 16'-0" B.O. DECK L.P. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A 13'-0" T.O. TRIM 3'-0" 16 0'-0" B.O. FIN. FLR 1 01 2 1 1 2 1 ELEVATION AT DINING S222A 42 4 26 PT-19 W312 PT-19 WC-02 13 W326 16'-0" B.O. DECK L.P. 13'-0" T.O. TRIM 7'-0" T.O. TRIM W303 0'-0" B.O. FIN. FLR 2 02 ELEVATION AT DINING 18 LARGE TRASH CAN. 19 BOOTH SEATING. 20 BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 21 DISPLAY PLATFORM ABOVE. 22 PARTIAL HEIGHT WALL AT QUEUING LINE. 23 END WALL AT SERVICE LINE. GC TO PROVIDE 5 8" DUROCK AT MILLWORK WALL TO RECEIVE TILE. 24 4X4 CEDAR POSTS AT BACK OF PLATFORM 25 CUSTOM POSTS AT FRONT OF PLATFORM, COORD WITH PSW REP. 26 STANDING TRIM 27 1X6 END TRIM 28 CHAIR RAIL. 29 CORNER MOULDING, TYPICAL AT ALL EXPOSED CORNERS. 30 SUBMARINE DUCT WITH ROTATING PROPELLER, REFER TO DETAIL 13/A5.2. 31 HVAC DUCT, PAINTED PT-19. REFER TO MECHANICAL SHEETS FOR INFORMATION. 32 MECHANICAL HOOD AT OVENS. 33 HANGING MARKETING SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. "YA GOTTA GET IT HOT" SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 34 W326 11 SMALL TRASH CAN. 2 SCALE: 3/8"=1'-0" PT-37 17 35 SOUP/SHAKE MENU BOARD. 36 SANDWICH MENU BOARD. 37 DESSERT MENU BOARD. 38 DECORATIVE TILE PANEL AT COOLER APRON 39 PAPER TOWEL DISPENSER 40 SOAP DISPENSER 41 WALL MOUTED SERVICE SINK 42 VINYL STORE LOGO AND HOURS 43 11X17 CHALKBOARD SIGN 44 OUR SANDWICHES SIGN 45 ORDER HERE FINGER 46 SOLID SURFACE COUNTER TOP AND TOP CAP. 1 SCALE: 3/8"=1'-0" R 4 0 4 S. C H Wells S t ., I T E Suite 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A4.1 INTERIOR ELEVATIONS.DWG PT-19 26 3 SHEET TITLE INTERIOR ELEVATIONS JYOU W312 PT-37 EXISTING COLUMN. SHEET NUMBER A4.1 12/21/2009 4:28:38 PM WR01 PT-09 2 PROJECT NUMBER: 16-059 PT-19 PT-09 EXISTING STOREFRONT SYSTEM TO REMAIN. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 PT-09 1 KEY NOTES 3 INTERIOR ILLUMINATED WINDOW SIGNAGE. PROVIDE POWER. REFER TO ELECTRICAL DRAWINGS. PT-19 4 ENTRY DOORS. 5 SWINGING SERVICE DOOR. 6 DOOR TRIM, REFER TO DETAIL 01/A2.0. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. 26 PT-19 12 A5.0 VINYL MARKETING MESSAGE ON WINDOW. 8 PROVIDE BLOCKING IN WALL 9 COOLER OPENING WITH TRIM SURROUND. REFER TO DETAIL 04/A5.0 . 10 1x2 WOOD TRIM. 11 CEDAR TONGUE AND GROOVE PANELS. 12 BEADBOARD PANELS. 13 CUSTOM WALLPAPER. 14 SODA CABINET. REFER TO MILLWORK AND PLUMBING SHEETS. 15 BACK BOARD CABINET-LOWEST SHELF TO BE 6" D. SERVICE LINE CABINETRY. REFER TO CASEWORK SHEET FOR INFORMATION. 16 WB-04 01 ELEVATION AT DINING 02 ELEVATION AT PARTIAL HEIGHT WALL SCALE: 3/8"=1'-0" PT-16 PT-19 WR01 SCALE: 3/8"=1'-0" PT-37 WC-01 13 PT-19 WR01 PT-19 S218 PT-03 16'-0" B.O. DECK L.P. 26 PT-19 W312 13'-0" T.O. TRIM 10'-0" B.O. SOFFIT PT-04 W305 4'-0" T.O. TRIM 12 SMALL TRASH CAN. 18 LARGE TRASH CAN. 19 BOOTH SEATING. 20 BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 21 DISPLAY PLATFORM ABOVE. 22 PARTIAL HEIGHT WALL AT QUEUING LINE. 23 END WALL AT SERVICE LINE. GC TO PROVIDE 5 8" DUROCK AT MILLWORK WALL TO RECEIVE TILE. 24 4X4 CEDAR POSTS AT BACK OF PLATFORM 25 CUSTOM POSTS AT FRONT OF PLATFORM, COORD WITH PSW REP. 26 STANDING TRIM 27 1X6 END TRIM 28 CHAIR RAIL. 29 CORNER MOULDING, TYPICAL AT ALL EXPOSED CORNERS. 30 SUBMARINE DUCT WITH ROTATING PROPELLER, REFER TO DETAIL 13/A5.2. 31 HVAC DUCT, PAINTED PT-19. REFER TO MECHANICAL SHEETS FOR INFORMATION. 32 MECHANICAL HOOD AT OVENS. 33 HANGING MARKETING SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. "YA GOTTA GET IT HOT" SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 34 7'-0" 28 7'-5 1/2" A.F.F. PT-37 17 35 SOUP/SHAKE MENU BOARD. 36 SANDWICH MENU BOARD. 37 DESSERT MENU BOARD. 38 DECORATIVE TILE PANEL AT COOLER APRON 39 PAPER TOWEL DISPENSER 40 SOAP DISPENSER 41 WALL MOUTED SERVICE SINK 42 VINYL STORE LOGO AND HOURS 43 11X17 CHALKBOARD SIGN 44 OUR SANDWICHES SIGN 45 ORDER HERE FINGER 46 SOLID SURFACE COUNTER TOP AND TOP CAP. 47 GLASS TILE ON FACE OF CHIP CUBBIE BASE. TYPICAL OF (3) SIDES. H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 2 WB-04 03 ELEVATION AT SERVICE LINE 14 WB-06 SCALE: 3/8"=1'-0" R S 0334 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 W304 0'-0" B.O. FIN. FLR E 955 ILLINOIS DESIGN FIRM # 184.006688 BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 W312 7 C Wells R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A4.2 INTERIOR ELEVATIONS.DWG EXISTING COLUMN. SHEET TITLE INTERIOR ELEVATIONS JYOU WR01 2 SHEET NUMBER A4.2 12/21/2009 4:29:06 PM PT-27 EXISTING STOREFRONT SYSTEM TO REMAIN. PROJECT NUMBER: 16-059 1 KEY NOTES 3 INTERIOR ILLUMINATED WINDOW SIGNAGE. PROVIDE POWER. REFER TO ELECTRICAL DRAWINGS. 4 ENTRY DOORS. 5 SWINGING SERVICE DOOR. 6 DOOR TRIM, REFER TO DETAIL 01/A2.0. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 7 VINYL MARKETING MESSAGE ON WINDOW. 8 PROVIDE BLOCKING IN WALL 9 COOLER OPENING WITH TRIM SURROUND. REFER TO DETAIL 04/A5.0 . 10 1x2 WOOD TRIM. 11 CEDAR TONGUE AND GROOVE PANELS. 12 BEADBOARD PANELS. 13 CUSTOM WALLPAPER. 14 SODA CABINET. REFER TO MILLWORK AND PLUMBING SHEETS. 15 BACK BOARD CABINET-LOWEST SHELF TO BE 6" D. SERVICE LINE CABINETRY. REFER TO CASEWORK SHEET FOR INFORMATION. 16 W322 01 ELEVATION AT FRON SERICE LINE WALL - INTERIOR SCALE: 3/8"=1'-0" S204 02 20 ELEVATION AT HALF WALL SCALE: 3/8"=1'-0" 8 17 SMALL TRASH CAN. 18 LARGE TRASH CAN. 19 BOOTH SEATING. 20 BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 21 DISPLAY PLATFORM ABOVE. 22 PARTIAL HEIGHT WALL AT QUEUING LINE. 23 END WALL AT SERVICE LINE. GC TO PROVIDE 5 8" DUROCK AT MILLWORK WALL TO RECEIVE TILE. 24 4X4 CEDAR POSTS AT BACK OF PLATFORM 25 CUSTOM POSTS AT FRONT OF PLATFORM, COORD WITH PSW REP. 26 STANDING TRIM 27 1X6 END TRIM 28 CHAIR RAIL. 29 CORNER MOULDING, TYPICAL AT ALL EXPOSED CORNERS. 30 SUBMARINE DUCT WITH ROTATING PROPELLER, REFER TO DETAIL 13/A5.2. 31 HVAC DUCT, PAINTED PT-19. REFER TO MECHANICAL SHEETS FOR INFORMATION. 32 MECHANICAL HOOD AT OVENS. 33 HANGING MARKETING SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. "YA GOTTA GET IT HOT" SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 34 4'-0" 3'-8" 6" W322 03 ELEVATION AT SERVICE LINE BACK WALL SCALE: 3/8"=1'-0" 20 WALL 04 ELEVATION AT HALF SCALE: 3/8"=1'-0" 35 SOUP/SHAKE MENU BOARD. 36 SANDWICH MENU BOARD. 37 DESSERT MENU BOARD. 38 DECORATIVE TILE PANEL AT COOLER APRON 39 PAPER TOWEL DISPENSER 40 SOAP DISPENSER 41 WALL MOUTED SERVICE SINK 42 VINYL STORE LOGO AND HOURS 43 11X17 CHALKBOARD SIGN 44 OUR SANDWICHES SIGN 45 ORDER HERE FINGER 46 SOLID SURFACE COUNTER TOP AND TOP CAP. 47 GLASS TILE ON FACE OF CHIP CUBBIE BASE. TYPICAL OF (3) SIDES. C H Wells S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 7'-0" 4 0 4 S. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A4.3 INTERIOR ELEVATIONS.DWG EXISTING COLUMN. SHEET TITLE INTERIOR ELEVATIONS JYOU 2 SHEET NUMBER A4.3 12/21/2009 4:29:41 PM EXISTING STOREFRONT SYSTEM TO REMAIN. PROJECT NUMBER: 16-059 1 KEY NOTES 31 PT-19 W312 WR01 26 PT-19 WR01 PT-19 PT-37 16'-0" B.O. DECK L.P. 16'-0" B.O. DECK L.P. 3 4 ENTRY DOORS. 5 SWINGING SERVICE DOOR. 6 DOOR TRIM, REFER TO DETAIL 01/A2.0. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A 13'-0" T.O. TRIM 13'-0" T.O. TRIM 4'-0" W312 EQ 26 PT-19 EQ 7'-0" 7'-0" B.O.HEADER 7'-6" 02 A5.0 02 A5.0 4'-0" T.O. WALL OPEN BEYOND 4'-0" T.O. WALL 7 VINYL MARKETING MESSAGE ON WINDOW. 8 PROVIDE BLOCKING IN WALL 9 COOLER OPENING WITH TRIM SURROUND. REFER TO DETAIL 04/A5.0 . 10 1x2 WOOD TRIM. 11 CEDAR TONGUE AND GROOVE PANELS. 12 BEADBOARD PANELS. 13 CUSTOM WALLPAPER. 14 SODA CABINET. REFER TO MILLWORK AND PLUMBING SHEETS. 15 BACK BOARD CABINET-LOWEST SHELF TO BE 6" D. SERVICE LINE CABINETRY. REFER TO CASEWORK SHEET FOR INFORMATION. 16 0'-0" B.O. FIN. FLR W312 01 S213 PT-04 0'-0" B.O. FIN. FLR WB-04 8 WB-04 ELEVATION AT DINING/DOOR TO PREP/TOILET VESTIBULE PT-16 SCALE: 3/8"=1'-0" PT-16 02 ELEVATION AT REAR EXIT PT-16 PT-16 8'-6" B.O. CEILING 7'-0" B.O. HEADER 28 PT-04 7'-0" B.O. HEADER W305 W305 PT-04 4'-0" T.O. TRIM W304 W304 0'-0" B.O. FIN. FLR. W308 03 ELEVATION AT RESTROOM SCALE: 3/8"=1'-0" 7'-0" B.O. HEADER 4'-0" T.O. WALL 0'-0" B.O. FIN. FLR 0'-0" B.O. FIN. FLR W308 04 ELEVATION AT RESTROOM SCALE: 3/8"=1'-0" 05 ELEV AT RR VESTIBULE SCALE: 3/8"=1'-0" SMALL TRASH CAN. 18 LARGE TRASH CAN. 19 BOOTH SEATING. 20 BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 21 DISPLAY PLATFORM ABOVE. 22 PARTIAL HEIGHT WALL AT QUEUING LINE. 23 END WALL AT SERVICE LINE. GC TO PROVIDE 5 8" DUROCK AT MILLWORK WALL TO RECEIVE TILE. 24 4X4 CEDAR POSTS AT BACK OF PLATFORM 25 CUSTOM POSTS AT FRONT OF PLATFORM, COORD WITH PSW REP. 26 STANDING TRIM 27 1X6 END TRIM 28 CHAIR RAIL. 29 CORNER MOULDING, TYPICAL AT ALL EXPOSED CORNERS. 30 SUBMARINE DUCT WITH ROTATING PROPELLER, REFER TO DETAIL 13/A5.2. 31 HVAC DUCT, PAINTED PT-19. REFER TO MECHANICAL SHEETS FOR INFORMATION. 32 MECHANICAL HOOD AT OVENS. 33 HANGING MARKETING SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. "YA GOTTA GET IT HOT" SIGN. REFER TO ELECTRICAL SHEETS FOR POWER REQUIREMENTS. 34 12 0'-0" B.O. FIN. FLR. 17 8'-6" B.O. CEILING 28 4'-0" T.O. TRIM 12 SCALE: 3/8"=1'-0" 06 ELEV AT RR VESTIBULE SCALE: 3/8"=1'-0" R 4 0 4 S. 35 SOUP/SHAKE MENU BOARD. 36 SANDWICH MENU BOARD. 37 DESSERT MENU BOARD. 38 DECORATIVE TILE PANEL AT COOLER APRON 39 PAPER TOWEL DISPENSER 40 SOAP DISPENSER 41 WALL MOUTED SERVICE SINK 42 VINYL STORE LOGO AND HOURS 43 11X17 CHALKBOARD SIGN 44 OUR SANDWICHES SIGN 45 ORDER HERE FINGER 46 SOLID SURFACE COUNTER TOP AND TOP CAP. 47 GLASS TILE ON FACE OF CHIP CUBBIE BASE. TYPICAL OF (3) SIDES. C H Wells S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A4.4 INTERIOR ELEVATIONS.DWG WR01 INTERIOR ILLUMINATED WINDOW SIGNAGE. PROVIDE POWER. REFER TO ELECTRICAL DRAWINGS. SHEET TITLE INTERIOR ELEVATIONS JYOU 13 EXISTING COLUMN. SHEET NUMBER A4.4 12/21/2009 4:30:21 PM WC-03 PT-27 2 PROJECT NUMBER: 16-059 PT-19 PT-03 EXISTING STOREFRONT SYSTEM TO REMAIN. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 PT-27 1 KEY NOTES 5'-9" BLOCKING 10'-6" B.O. CEILING 10'-6" B.O. CEILING 6'-11" BLOCKING 3 MANAGERS DESK. REFER TO DETAIL 12/A5.1 FOR ADDITIONAL INFO. 4 PROVIDE BLOCKING IN WALL 5 MOP BASIN. REFER TO PLUMBING DRAWINGS. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. C H Wells S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 0'-0" B.O. FIN. FLR 3 ELEVATION AT PREP ROOM 13 SCALE: 3/8"=1'-0" 02 13 ELEVATION AT PREP ROOM 7 WALL MOUNTED HAND SINK. REFER TO PLUMBING DRAWINGS. 8 3-COMP. SINK. REFER TO PLUMBING DRAWINGS. 9 SOAP DISPENSER 10 SHELVING ON CASTERS 11 PAPER TOWEL DISPENSER 12 WALK-IN COOLER/FREEZER 13 STAINLESS STEEL CORNER GUARD 14 BAG-N-BOX. REFER TO DETAIL 11/A5.0 SCALE: 3/8"=1'-0" 10'-6" B.O. CEILING WALK IN COOLER 0'-0" B.O. FIN. FLR PREP TABLE. REFER TO PLUMBING DRAWINGS THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. 2 04 A5.2 10'-6" B.O. CEILING 6 15 NOT USED 16 LOCATION OF CHEMICAL DISPENSER. 17 6" DIA. PVC SLEEVE LOCATED IN GYP. BD. SOFFIT FOR SODA LINES. REFER TO DETAIL 11/A5.0 18 WATER HEATER. PROJECT NUMBER: 16-059 01 8 EMPLOYEE COAT HOOKS 6'-2" 4'-0" 5'-2" 4'-0" 3'-9" 0'-0" B.O. FIN. FLR WB-01 2 ILLINOIS DESIGN FIRM # 184.006688 6'-4" 7'-7" 6'-0" BLOCKING 3'-8" BLOCKING ELECTRICAL PANELS BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 4 1 0'-0" B.O. FIN. FLR ISSUE DATE R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A4.5 INTERIOR ELEVATIONS.DWG SCALE: 3/8"=1'-0" DATE 04-26-2016 05-23-2016 SHEET TITLE INTERIOR ELEVATIONS JYOU 3'-0" FAUCET 0'-0" B.O. FIN. FLR. 16 3'-0" FAUCET 6'-3" SHELF SCALE: 3/8"=1'-0" ELEVATION AT PREP ROOM 04 6'-3" SHELF ELEVATION AT PREP ROOM 03 ISSUE DD SET 95% SET 05 ELEV. AT UTILITY ROOM SCALE: 3/8"=1'-0" 06 ELEV. AT UTILITY ROOM SCALE: 3/8"=1'-0" 07 ELEV. AT UTILITY ROOM SCALE: 3/8"=1'-0" 08 ELEV. AT UTILITY ROOM SCALE: 3/8"=1'-0" A4.5 12/21/2009 4:30:21 PM SHEET NUMBER 5/8" GYP BD ON 3 5/8" METAL STUD FRAMING WOOD CAP W313 15 A5.0 COOLER APRON PACKAGE W320 TILE JAMB WITH SEALANT AT SIDES, NOT GROUT (TILE TO MATCH TILE BEHIND SERVICE LINE) A W300 W319 SCALE: 1 1/2" = 1'-0" 03 SCALE: 3" = 1'-0" 07 SECTION @ END CONDITON SCALE: 1" = 1'-0" 08 SECTION @ LOW WALL GYP BD / METAL STUD WALL SCALE: 1" = 1'-0" 09 CLOSURE DETAIL SCALE: 3" = 1'-0" WOOD ROSETTE W316 10 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 10 1/2" 10 1/2" 2" 6 1/2" WOOD APRON W309 STAINLESS STEEL CLOSURE STRIPS ATTACHED TO COOLER WALL ONLY FROM VENDOR E 300 1" WOOD TRIM (2X2 CUT TO SIZE) W313 COOLER HEAD SCALE: 3" = 1'-0" ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 1 1/2" DIA. EYEBOLT ON IRON STANCHION COOLER W302 PREFABRICATED COOLER QUEUING LINE METAL CHAIN CONT. SEALANT (BOTH SIDES TYP.) 7 3/4" QUARTER ROUND TRIM 2 1/2" QUARRY TILE BASE W306 QUARRY TILE FLOORING ON THINSET GROUT OVER WATERPROOF MEMBRANE CEDAR TONGUE & GROOVE PLANKS W303 SMOOTH FACE OUTGC TO STAIN CEDAR ST-06 VARIES 7'-0" TOP OF WOOD TRIM 7'-7" CO2 TANK SECURED TO RACK WITH CHAIN BY GC W300 W319 GYP BD WALL TILE JAMB 3/4" BASE PLATE W/ 3/8" X 3" CONCRETE WEDGE FASTENERS SILICONE BEAD AT PERIMETER (CLEAR) WALK-IN COOLER EXISTING CONCRETE SLAB SHEET TITLE NOTE: PAINT FASTENERS TO MATCH BASE PLATE. DO NOT PAINT UNFINISHED WROUGHT IRON STANCHION WOOD BASE WB04 LEAVE 7 1/2" MIN. GAP FOR BIB PUMP DOOR CASING W/ BACK BAND 1/4" MIN. WROUGHT IRON STANCHIONS BAG IN THE BOX RACKS R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A5.0 INTERIOR DETAILS.DWG POPLAR TOP CAP WATER LINE WALL SHELF FOR CARBONATOR QUEUING LINE TILE JAMB 6" DIA. PVC SLEEVE FOR SODA LINES ELECTRICAL OUTLET CL @ 7'-7" SILICONE BEAD AT PERIMETER (CLEAR) WALK-IN COOLER WOOD BASE WB04 NOTE: LEAVE 2" GAP AT SIDE AND BACK WALL BLOCKING IN WALL SILICONE BEAD AT PERIMETER (CLEAR) PREFAB COOLER WALLS FROM VENDOR T Suite NOTE: IF NOT SLAB ON GRADE, COOLER WILL BE PROVIDED WITH INTEGRAL FLOORING. NO QUARRY TILE FLOOR OR BASE INSIDE COOLER WHEN NOT SLAB ON GRADE NOTE: ALL DISSIMILAR MATERIALS TO HAVE FLEXIBLE GROUT INTERIOR DETAILS JYOU SCALE: 1/2" = 1'-0" WOOD BASE WB04 3/4" SQ WELDED BASE PLATE W/ 3/8" X 3" CONCRETE WEDGE FASTENERS DOOR CASING W300 1" CLEAR BETWEEN GYP BD AND COOLER WALL 3 5/8" METAL STUD WITH 2" X 2" STEEL PIPE W/ 3/4" SQ WELDED BASE PLATE W/ 3/8" X 3" CONCRETE WEDGE FASTENERS (WALL TYPE 8) 3'-0" 6" MILLWORK SODA CABINET 4'-0" TO T.O. WOOD TRIM WOOD CORNER TRIM W301 AT ALL (4) EDGES GC TO PAINT PT-04 WOOD CAP W313 1 1/2" 1'-2" 4'-0" TO T.O. WOOD TRIM 3/4" PLYWOOD PANELS W317 OVER METAL STUDS ON OUTSIDE FACE - BOTH SIDES GC TO STAIN ST-06. 3/4" PLYWOOD PANELS W317 ON OUTSIDE FACE - BOTH SIDES GC TO STAIN ST-06 I SCALE: 3/4" = 1'-0" 1" MIN. 6" DIA. PVC CENTERED IN CHASE S t ., SEALANT 2" 12" X 12" CEDAR TOP CAP, SIMILAR TO W315 GC TO STAIN ST-06 5/8" GYP BD, TYP. 06 COOLER OPENING - SECTION ELEVATION CEDAR TOP CAP W315 GC TO STAIN ST-06 METAL STUDS CHASE @ SODA CABINET 04 B.O. SILL A.F.F. HOLD END COND. @ LOW WALL COOLER APRON PACKAGE W320 ALIGN WITH B.O. CEDAR CAP 1'-3 1/2" 02 SCALE: BEADBOARD WAINSCOT 7 3/4" 1/4 MIN. 01 NOT USED EDGE OF CEDAR TOP CAP 11 1/2" SILICONE BEAD AT PERIMETER (CLEAR) 1'-0" LINE OF WOOD CUT PATTERN AT CAP, TYP. H 2X8 CEDAR CAP (1" OVERHANG) W315 5 1/2" WOOD BASE WB04 C Wells THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. DOOR CASING W/ BACK BAND BEYOND 2X8 CEDAR CAP (1" OVERHANG) W315 5'-0" HOLD R 4 0 4 S. PROJECT NUMBER: 16-059 OPEN FOR REACH-IN COOLER 6'-5 1/2" 5'-7" OPENING IN COOLER 5'-5 1/2" 9" PARTIAL HGT. WALL 1'-0" MILLWORK CAP 5'-3 3/4" R.O. QUEUING LINE 2" 8" MILLWORK CAP 5" PARTIAL HGT. WALL 4'-0" TOP TO WOOD TRIM W304 OR W317 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM - BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 5'-2" DOOR FLANGE 10 5'-8 3/4" DOOR FLANGE 10 A5.0 ROUGH OPENING WOOD APRON W309 WALK-IN WOOD TRIM COOLER W313 DOOR CASING W/ BACK BAND W300 W319 7 3/4" 7 3/4" DOOR CASING W300 WOOD ROSETTE W316 5'-8 3/4" 7 3/4" 7 3/4" 3 5/8" METAL STUD WALL, TYP. 1'-0" MILLWORK CAP 9" PARTIAL HGT. WALL 2" BEADBOARD OR PLYWOOD PANELS AS NOTED ON INTERIOR ELEVATIONS 07 A5.0 5'-10" CHAIR RAIL W305 GC TO PAINT PT-04 SHEET NUMBER 11 BAG-N-BOX SCALE: 1/2" = 1'-0" 12 CEDAR PANELING SCALE: 1 1/2" = 1'-0" 13 STANCHION DETAIL SCALE: 1 1/2" = 1'-0" 14 COOLER BASE SCALE: 1 1/2" = 1'-0" 15 COOLER JAMB SCALE: 3" = 1'-0" A5.0 2/4/2010 2:24:57 PM 7 1/2" 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. C Wells H S t ., I T E Suite 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. 03 SCALE: NOT USED SCALE: 2'-0" COMPRESSOR ALLOW ADEQUATE SPACE & VENTILATION FOR TOP MOUNT COMPRESSOR. GC TO PROVIDE ACCESS FOR SERVICE. REFER TO CONSTRUCTION PLAN PHONE SYSTEM 1'-2" PRINTER SHRED SAFE 3'-2" 2'-2" 2'-3" FILE CABINET 1'-6" 3'-8" NETBOOK 4'-10 1/2" SERVER 1'-9" 12 POWER SUPPLY 3'-9 3/4" 6'-0" BLOCKING MUSIC PLAYER & AMP T-STATS EMPTY JBOX FOR FUTURE DESK TOP ON WALL BRACKETS 5/8" DRYWALL TO BOX LOCKABLE CABINET 07 A5.1 SWITCH VOLUME CONTROLS PHONE CEDAR TOP CAP DOOR FRAME R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A5.1 INTERIOR DETAILS.DWG PROVIDE BLOCKING IN WALL 5'-0 3/4" COOLER OPENING 1/4" TILE TO BOX PATCH PANEL 1'-2" OPENING DATE 04-26-2016 05-23-2016 5/8" FLANGE 6'-0" BLOCKING 3'-6" 1'-9" 1'-9" J BOX ADJUSTABLE SHELF ON WALL STANDARDS ISSUE DD SET 95% SET 5'-2" DOOR FLANGE NOTE: REFER TO DETAIL 7/E7.0 FOR POWER & DATA RECEPTACLE LOCATIONS ISSUE DATE G.C. TO INSTALL TRIM AFTER DOOR IS INSTALLED SCALE: 1/2" = 1'-0" 66 BLOCK 07 SCALE: SECTION AT COOLER 7'-9" 06 NOT USED 1'-0" 10 1/2" 11 1/2" 5/8" GYP BD TO BOX 5'-3 3/4" ROUGH OPENING 1/4" TILE TO BOX 5'-7" 5/8" FLANGE 5'-8 1/4" 5'-10" ROUGH OPEN'G TILE BAND W/ SEALANT, NOT GROUT 8'-6" DOOR FRAME WALL MOUNTED EQUIPMENT RACK SHEET TITLE INTERIOR DETAILS MONITOR ARM JYOU SCALE: NOT USED SHEET NUMBER ELEV AT MANAGER DESK SCALE: 1/2" = 1'-0" 13 NOT USED SCALE: 14 PLAN AT COOLER SCALE: 1/2" = 1'-0" A5.1 3/30/2010 3:45:27 PM 02 PROJECT NUMBER: 16-059 NOT USED BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 01 8'-6" A.F.F. B.O. GYP. CLG. CEILING TILE TO RETURN VERTICALLY TO TOP OF COOLER SUSPENDED GRID SYSTEM SUSPENDED ACT CEILING METAL PANELS IN SUSPENDED GRID 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM 10'-6" A.F.F T.O. FIN. FLOOR WOOD APRON W309 FRT WOOD BLOCKING 7'-0" A.F.F. B.O. HEADER HALLWAY R 4 0 4 S. C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 ALIGN 1/4" SHIM SPACE A THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. DINING WALK-IN COOLER WOOD CASING W308 WALL BEYOND 5" HEADER AT T.R. VESTIBULE SCALE: 3"=1'-0" SOFFIT AT COOLER DETAIL 04 SCALE: 1" = 1'-0" PROVIDE SECONDARY UNISTRUT FRAMING TO EXISTING ROOF STRUCTURE (AS REQUIRED) 05 CLG TRIM DETAIL SCALE: 3"=1'-0" PROVIDE SECONDARY UNISTRUT FRAMING TO EXISTING ROOF STRUCTURE (AS REQUIRED) RIGID CONDUIT FROM CEILING TO J-BOX RIGID CONDUIT FROM CEILING TO J-BOX GC TO ATTACH CHAIN TO UNISTRUT ALL THREAD HARDWARE TO STABILIZE TRACK FIXTURE TO UNISTRUT AND TRACK SPACED AS REQUIRED ALONG TRACK LENGTH B.O. J-BOX 12'-9" A.F.F. (SEE NOTE) B.O. J-BOX CUSTOM MARKETING SIGN TO SLIDE IN TO FRAME J-BOX J-BOX LIGHT FIXTURE AS SCHEDULED TRACK END FEED LIGHT FIXTURE AS SCHEDULED 8'-0" A.F.F. B.O. SIGN NOTE: J-BOX AT 11'-6" A.F.F.: INTERIOR DECORATIVE FIXTURES (L100, L101, L102, L107, L108) J-BOX AT 16'-1" A.F.F.: FIXTURE L109 12'-0" A.F.F. (SEE NOTE) B.O. FIXTURE SCALE: 07 TRACK FIXTURE MOUNTING SCALE: 1-1/2"=1'-0" 08 MARKETING HANGING SIGN SCALE: N.T.S. PROVIDE SECONDARY UNISTRUT FRAMING TO EXISTING ROOF STRUCTURE (AS REQUIRED) LIGHT FIXT MOUNTING 09 SCALE: 1 1/2"=1'-0" PROVIDE SECONDARY UNISTRUT FRAMING TO EXISTING ROOF STRUCTURE (AS REQUIRED). EC TO PROVIDE BRACING AT STRUCTURE X'-X" MAX ALL THREAD HARDWARE TO STABILIZE TRACK FIXTURE TO UNISTRUT AND TRACK SPACED AS REQUIRED ALONG TRACK LENGTH PROPELLER & NOSE 13'-0" A.F.F. (SEE NOTE) B.O. FIXTURE SCALE: 1 1/2" = 1'-0" SUSPENDED GRID SYSTEM TYP. TRACK END FEED LIGHT FIXTURE AS SCHEDULED SCALE: WOOD TRIM CAP ST-04 W313 METAL PANELS IN SUSPENDED GRID 12-0" A.F.F. (DECK) T.O. J-BOX J-BOX TRACK FIXTURE MOUNTING GYP BD UP TO B.O. CEILING STRUCTURE EC TO PROVIDE BALL JOINT AT J-BOX 13'-9" A.F.F. (SEE NOTE) B.O. J-BOX 12 PROVIDE DIAG METAL STUD RE-INFORCMENT FROM B.O. SOFFIT BACK TO STRUCTURE, TYP. RIGID CONDUIT FROM CEILING TO J-BOX J-BOX NOT USED SCALE: DATE 04-26-2016 05-23-2016 3 5/8" STUD SOFFIT WALL AT 16" O.C. TIED BACK TO DECK, TYP. 12" SPIRAL DUCT RIGID CONDUIT FROM CEILING TO J-BOX 11 10 NOT USED ISSUE DD SET 95% SET 5 1/2" 06 NOT USED ISSUE DATE R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A5.2 INTERIOR DETAILS.DWG SCALE: 03 13 NOTE: BOTTOM OF LOWEST PORTION OF DUCT TO BE AT 10'-0" AFF. PAINT FINISH TO BE SEMI-GLOSS GRAPHIC STICKERS TO BE PROVIDED BY OWNER AND INSTALLED BY GC SUBMARINE FINISH DETAIL SCALE: NTS 10'-0" A.F.F SWIVEL PLATE CEILING FAN EXTENSION ROD AS SCHEDULED B.O. BULKHEAD FRT WOOD BLOCKING 1X6 (BEYOND) W309 ST-04 14 CEILING FAN MOUNTING SCALE: 3"=1'-0" 15 5 1/2" WOOD APRON ST-04 W309 CEILING TRIM DETAIL SCALE: 3"=1'-0" SHEET TITLE INTERIOR DETAILS JYOU NOT USED SHEET NUMBER A5.2 3/30/2010 3:48:03 PM SCALE: 02 PROJECT NUMBER: 16-059 NOT USED BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 01 SERVICE RESTROOM MARBLE THRESHOLD THINSET TO BE TAPERED @ LAST TIME COURSE 5" 1/2" 1 4" 1/4"MAX. MAX. 6" BULLNOSE TILE 6" 1 38" 1/2" MAX. 1/4"MAX. 1/4" MAX. WHITE TILE FT03 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM MOSAIC TILE QUARRY TILE-SET IN THIN SET MORTAR BED CONCRETE SLAB 1'-0" DINING CAFE DOOR WHERE OCCURS 1/2" TOTAL 1'-0" BLACK BORDER TILE FT04 DINING WATERPROOFING MEMBRANE (WHERE APPLICABLE) 1/8" X 1/8" SCORING PER PLAN A R 4 0 4 S. C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. EXISTING CONCRETE SLAB SCORING PER PLANREFER TO FINISH PLAN 02 EXTERIOR TRANSITION DETAIL SCALE: 3"=1'-0" PREP 04 NOT USED SCALE: DINING DINING 05 MARBLE THRESHOLD SCALE: 3" = 1'-0" WOOD OR METAL STUD WALL BEYOND EXTERIOR CERAMIC TILE - REFER TO FINISH SCHEDULE MOISTURE RESISTANT GYPSUM BOARD FROM 6" TO CEILING 1/2" TOTAL WEATHER STRIPPING WEATHER STRIPPING EXISTING FOUNDATION THINSET TO BE TAPERED @ LAST TIME COURSE SEALED CONCRETE FLOORING CONTINUOUS WATERPROOFING 6" UP WALL INTEGRAL QUARRY TILE COVE BASE W/ BULLNOSE EDGE QUARRY TILE FLOORING 6" CONC. SCORING EXISTING CONCRETE SLAB WATERPROOFING THROUGHOUT PREP AREA, SERVICE LINE BACK WALL AND AT KITCHEN AT NON-SLAB ON GRADE CONDITIONS ONLY-APPLY TO FACE OF DUROCK 6" HIGH (TYP.) EXISTING FOUNDATION NOTE: PROVIDE ANODIZED BRONZE THRESHOLD NOTE: RUN WATERPROOFING TO TOP OF DUROCK . REFER TO FLOOR PLANS FOR LOCATIONS. WATERPROOFING TO BE OF CONTINUOUS APPLICATION W/ FLOOR WATERPROOFING FOR TOTAL WATERPROOF SEAL. ISSUE DATE NOTE: PROVIDE ANODIZED BRONZE THRESHOLD 06 TRANSITION DETAIL SCALE: 3" = 1'-0" 07 NOT USED SCALE: 08 TRANSITION DETAIL SCALE: 3"=1'-0" 09 TRANSITION DETAIL SCALE: 3"=1'-0" 10 QUARRY TILE COVE BASE SCALE: 3"=1'-0" FRP - REFER TO FINISH SCHEDULE (END 2" FROM THE FLOOR) CERAMIC TILE - REFER TO FINISH SCHEDULE MOISTURE RESISTANT GYPSUM BOARD FROM 6" TO CEILING MOISTURE RESISTANT GYPSUM BOARD FROM 6" TO CEILING CONTINUOUS SEALANT 5/8" DUROCK (6" HIGH) 1'-0" DUROCK 1'-0" DUROCK CONTINUOUS SEALANT CONTINUOUS WATERPROOFING 6" UP WALL INTEGRAL QUARRY TILE COVE BASE W/ BULLNOSE EDGE QUARRY TILE FLOORING 5/8" DUROCK (6" HIGH) CONTINUOUS WATERPROOFING 6" UP WALL BULLNOSE CERAMIC TILE COVE BASE CERAMIC TILE & GROUT BED 2" TAPERED ALUMINUM FRAME BLACK FINISH DATE 04-26-2016 05-23-2016 WOOD OR METAL STUD WALL BEYOND WOOD OR METAL STUD WALL BEYOND HELIX WALK OFF MAT BY GRAND ENTRANCE ISSUE DD SET 95% SET R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A5.3 INTERIOR DETAILS.DWG EXISTING CONCRETE SLAB CONCRETE SLAB 5/8" DUROCK (6" HIGH) 1/8" MAX. BULLNOSE TILE 1/2" MAX. BACKER ROD & SEAL DOOR- SEE SCHEDULE BACKER ROD & SEAL 1/8" MAX. HELIX WALK OFF MAT BY GRAND ENTRANCE QUARRY TILE-SET IN THIN SET MORTAR BED CONTINUOUS SEALANT 1/2" MAX. DOOR- SEE SCHEDULE FULL SADDLE ANODIZED BRONZE THRESHOLD SET IN CONT. SEALANT BED BY G.C.- REFER TO FLOOR FINISH PLAN SHEET 1'-0" DUROCK PREP DOOR WHERE OCCURS FULL SADDLE ANODIZED BRONZE THRESHOLD SET IN CONT. SEALANT BED BY G.C.- REFER TO FLOOR FINISH PLAN SHEET EXISTING CONCRETE SLAB WATERPROOFING THROUGHOUT PREP AREA, SERVICE LINE BACK WALL AND AT KITCHEN AT NON-SLAB ON GRADE CONDITIONS ONLY-APPLY TO FACE OF DUROCK 6" HIGH (TYP.) NOTE: RUN WATERPROOFING TO TOP OF DUROCK . REFER TO FLOOR PLANS FOR LOCATIONS. WATERPROOFING TO BE OF CONTINUOUS APPLICATION W/ FLOOR WATERPROOFING FOR TOTAL WATERPROOF SEAL. SURFACE MOUNTED TAPERED ALUMINUM FRAME CONTACT LOCAL IMPACT SPECIALTIES FOR MORE INFORMATION. 11 WALK OFF MAT SCALE: 3" = 1'-0" 12 WALK OFF MAT SCALE: 13 NOT USED SCALE: 14 TILE COVE BASE @ FRP SCALE: 3"=1'-0" WATERPROOFING THROUGHOUT TOILET ROOM AT NON-SLAB ON GRADE CONDITIONS ONLY- APPLY TO FACE OF DUROCK 6" HIGH (TYP.) NOTE: RUN WATERPROOFING TO TOP OF DUROCK . REFER TO FLOOR PLANS FOR LOCATIONS. WATERPROOFING TO BE OF CONTINUOUS APPLICATION W/ FLOOR WATERPROOFING FOR TOTAL WATERPROOF SEAL. 15 CERAMIC TILE COVE BASE SCALE: 3"=1'-0" SHEET TITLE INTERIOR DETAILS JYOU DINING SCALE: 3"=1'-0" 03 SHEET NUMBER A5.3 3/30/2010 3:53:03 PM SCALE: ENLARGED MOSAIC DETAIL PROJECT NUMBER: 16-059 NOT USED BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 01 3'-0" ALL SUBSTRATE BEHIND PANEL REVEALS TO BE PAINTED BLACK BY G.C. 1 1/2" 3-5/8" METAL STUD @ 16" O.C. WITH 1/2" PLYWOOD AND FRP ON SERVICE SIDE (BY GC) 1" 1 1/2" 1" WOOD BLOCKING, TYP. 1" SOLID SURFACE TOP CAP CN-03 (BY RETAIL, INSTALLED BY GC) BOLTED TO BLOCKING FROM UNDERNEATH 1 1/2" QUARRY TILE BASE 6" CEMENT BOARD WITH CERAMIC TILE BASE WB-06 (BY GC) 1" 1'-11" 7 1/4" CLEAT ATTACHMENT (BY RETAIL, INSTALLED BY GC) ON 21" PLYWOOD SUBSTRATE, 5" STRIP (BY GC) 1 2" 04 - 10" 3/4" SCALE: 1" = 1'-0" 02 1' X 1' ACCESS PANEL (BY GC) (2) LAYERS 21" PLYWOOD ON 1" HAT CHANNEL (BY GC) WITH CERAMIC TILE (WT-11) 9/16" ORDER/LOAD STATION SCALE: 1"=1'-0" 03 CHIP CUBBIE SCALE: 1"=1'-0" R 4 0 4 S. C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. CERAMIC TILE WT-11 (PROVIDED AND INSTALED BY GC) STAINLESS STEEL TILE EDGE FINISH TRIM, SCHLUTER RONDEC OR EQUAL (BY GC) 4 3/4" 7" STAINLESS STEEL TILE CORNER FINISH TRIM, SCHLUTER ECK-K (169 ") OR EQUAL (BY GC) A 04 CHIP CUBBIE CORNER DTL SCALE: 3"=1'-0" PROJECT NUMBER: 16-059 BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 ADA COUNTER/POS COUNTER 1" HAT CHANNEL (BY GC) (2) LAYERS 21" PLYWOOD ON 1" HAT CHANNEL (BY GC) CEMENT BOARD WITH CERAMIC TILE BASE WB-06 (BY GC) 4 3/4" 7" CERAMIC TILE WT-11 (PROVIDED AND INSTALED BY GC) 1 2" QUARRY TILE BASE (BY GC) 1 1/2" (2) 3 5/8" METAL STUD @ 16" O.C. WITH 21" PLYWOOD/FRP ON SERVICE SIDE (BY GC) 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM 5'-0" 8 1/4" 3 4" 9" CEMENT BOARD WITH CERAMIC TILE BASE WB-06 (BY GC) 1'-10 1/4" 1'-0" 1 2" 3-5/8" METAL STUD @ 16" O.C. WITH 1/2" PLYWOOD AND FRP ON SERVICE SIDE (BY GC) 6" 4'-1 1/2" 4'-2 1/2" 2" DIA. PIPE LEG (BY RETAIL, INSTALL BY GC) SEE FLOOR PLAN FOR LOCATION 5" 1-1/2" WOOD PANEL W/ WALL CLEATS (BY RETAIL, INSTALLED BY GC) 2'-10" 5" 5" CLEAT ATTACHMENT (BY RETAIL, INSTALLED BY GC) ON 21" PLYWOOD SUBSTRATE, 5" STRIP (BY GC) 3 1/2" 4'-4" 3/4" CHIP CUBBIE BOLT TO BLOCKING (BY PSW, INSTALLED BY GC) FRP UP BACK OF CHIP CUBBIE WOOD BLOCKING, TYP. 3 4" 01 ALL SUBSTRATE BEHIND PANEL REVEALS TO BE PAINTED BLACK BY G.C. 9 1/2" 9/16" SOLID SURFACE COUNTERTOP CN03 (BY RETAIL, INSTALL GC) ISSUE DATE R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A5.4 INTERIOR DETAILS.DWG SHEET TITLE INTERIOR DETAILS JYOU SCALE: DATE 04-26-2016 05-23-2016 SHEET NUMBER A5.4 3/30/2010 3:53:03 PM 05 NOT USED ISSUE DD SET 95% SET DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS B1-10 CONTRACT DOCUMENTS: WILL BE MADE AVAILABLE FOR REPRODUCTION AND USE VIA THE POTBELLY FTP SITE. BIDDING INSTRUCTIONS B1-01 PROPOSALS A) PROPOSALS ON COMPLETE WORK ON EACH DIVISION AS DESCRIBED IN FOLLOWING SPECIFICATIONS, IN SUCH SUBSEQUENT ADDENDA AS MAY BE ISSUED DURING PERIOD OF BIDDING, AND SHOWN IN ACCOMPANYING DRAWINGS WILL BE RECEIVED AT THE TIME AND PLACE AS DIRECTED BY POTBELLY HEREINAFTER REFERRED TO AS POTBELLY REPRESENTATIVE. B) BASE PROPOSALS ON MATERIALS AND METHODS DESCRIBED IN SPECIFICATIONS, INCLUDE ALL LOCAL, STATE AND FEDERAL TAXES IN BID. QUOTE ALL ALTERNATES AND UNIT PRICES LISTED, FOR WHICH PRICE SHALL BE TOTAL COST TO OWNER INCLUDING ALL OVERHEAD AND PROFIT. C) LIST SUBCONTRACTORS, MATERIAL SUPPLIERS AND MANUFACTURERS IN SPACES PROVIDED ON FORM OF PROPOSAL. B1-02 STANDARDS A) ARTICLES, DEVICES, MATERIALS, FORMS OF CONSTRUCTION, FIXTURES, ETC., NAMED IN SPECIFICATIONS TO DENOTE KIND AND QUALITY DESIRED ARE "STANDARDS". BASE ALL PROPOSALS ON SAME. B) ANY MAKE OF MATERIALS AND APPARATUS SPECIFIED ACCEPTABLE TO OWNER, UNLESS OTHERWISE STATED. BASE BID ON ANY MAKE SPECIFIED, CONTRACTOR NOT REQUIRED TO STATE SELECTION OF SPECIFIED MAKE UNTIL AFTER AWARD OF CONTRACT, EXCEPT THOSE REQUIRED LISTED ON BID DATE ON FORM OF PROPOSAL. C) CONTRACTORS SHALL BID PROJECT USING STANDARDS SPECIFIED. SUCCESSFUL BIDDER SHALL MAKE WRITTEN APPLICATION FOR APPROVAL OF OTHER MATERIAL OR APPARATUS WHEN SPECIFICATIONS REFER TO "OR APPROVED," ETC. BIDDER DESIRING TO PROPOSE SUBSTITUTIONS MAY DO SO IN ACCORDANCE WITH ARTICLE B1-03 AND SECTION 016000. B1-03. FINAL APPROVAL OF SUCH PROPOSALS WILL BE THE POTBELLY DIRECTOR OF CONSTRUCTION. B1-03 SUBSTITUTIONS A) IT IS NOT THE INTENT OF SPECIFICATIONS TO EXCLUDE USE OF MERITORIOUS PRODUCTS OF EQUAL VALUE. EXCEPT WHERE PRODUCTS ARE SPECIFIED "NO SUBSTITUTION," BIDDERS ARE INVITED TO SUBMIT SUBSTITUTIONS WITH THEIR BIDS OF OTHER MAKES OF MATERIAL AND APPARATUS FOR ARCHITECT AND OWNER CONSIDERATION. B) IF BIDDER PROPOSES SUBSTITUTIONS OF MATERIALS, FIXTURES, ARTICLES, DEVICES, METHODS OF CONSTRUCTION, ARRANGEMENT OF COMPONENTS, OR OTHER ITEMS DIFFERENT FROM THOSE CALLED FOR BY DRAWINGS AND SPECIFICATIONS, BID PRICE FOR SUBSTITUTIONS MUST INCLUDE ALL COSTS INVOLVED. INCLUDING ANY AND ALL COSTS FOR WORK REQUIRED BY OTHER CONTRACTORS OR SUBCONTRACTORS NECESSITATED BY PROPOSED SUBSTITUTION, OR CHANGE. BIDDERS DESIRING CONSIDERATION FOR THE USE OF MATERIALS, EQUIPMENT, ETC., NOT IN SPECIFICATIONS MAY SUBMIT PROPOSALS FOR SUBSTITUTIONS OF SAME FOR STANDARDS AS SPECIFIED, USING "SUBSTITUTION FORM" ATTACHED TO FORM OF PROPOSAL LISTING. FOR EACH PROPOSED CHANGE (1) "STANDARD" SPECIFIED, (2) SUBSTITUTION, AND (3) CHANGE IN BID PRICE, (OR "NO CHANGE"). FURNISH OWNER COMPLETE SPECIFICATIONS AND DESCRIPTION OF PROPOSED SUBSTITUTION CONSIDERED FOR ACCEPTANCE, UPON REQUEST. C) SUBSTITUTIONS ACCEPTED MUST BE INCORPORATED IN FORMAL CONTRACT. NO SUBSTITUTIONS ALLOWED SUBSEQUENT TO AWARD OF CONTRACT. SUBSTITUTIONS WILL NOT AFFECT DETERMINATION OF LOWEST BID. D) IF BIDDER NAMES NO SUBSTITUTE ON HIS "SUBSTITUTION SHEET", "STANDARDS" SPECIFIED SHALL BE USED. OWNER RESERVES RIGHT TO ACCEPT ANY ALTERNATE, OR SUBSTITUTION BID PROVIDED SUCH ACTION TAKEN IN SUFFICIENT TIME NOT TO DELAY PROGRESS OF WORK, OR INCUR ADDITIONAL EXPENSE TO CONTRACTOR. B1-04 ADDENDA: LIST ADDENDA ISSUED DURING BIDDING PERIOD ON FORM OF PROPOSAL, AND IN CLOSING CONTRACT, THEY SHALL BECOME A PART THEREOF. BIDDER IS RESPONSIBLE FOR TRANSMITTING ADDENDA INFORMATION TO ALL CONCERNED WITH HIS BID. ACKNOWLEDGE RECEIPT OF ADDENDA IN SPACE PROVIDED, ON FORM OF PROPOSAL. B1-05 PROPOSAL FORMS (BID FORMS) A) SUBMIT PROPOSAL ON FORM PROVIDED, FULLY COMPLETING ALL BLANK SPACES IN FORM; STATE TOTAL BOTH IN WRITING AND IN FIGURES; SIGNATURE SHALL BE IN LONGHAND AND COMPLETED FORM SHALL BE WITHOUT INTERLINEATION, ALTERATION, OR ERASURE. SUBMIT PROPOSALS IN DUPLICATE, MARKED ON OUTSIDE OF ENVELOPE WITH TITLE OF WORK AND NAME OF BIDDER. OBTAIN PROPOSAL FORMS FROM POTBELLY REPRESENTATIVE AND MAIL, OR DELIVER BID PER HIS INSTRUCTIONS. B) ALL BIDDERS ARE CAUTIONED TO ALLOW AMPLE TIME FOR TRANSMITTAL OF BIDS. BID RECEIVED AFTER SPECIFIED TIME WILL NOT BE ACCEPTED OR RECOGNIZED. THE TIME OF RECEIPT WILL DETERMINE THE ACCEPTABILITY OF MAILED BIDS, REGARDLESS OF POSTMARK. C) ANY BID MAY BE WITHDRAWN PRIOR TO THE TIME SCHEDULED ABOVE FOR THE OPENING OF BIDS OR AUTHORIZED POSTPONEMENT THEREOF. NO BID MAY BE WITHDRAWN FOR THIRTY (30) DAYS, SATURDAYS, SUNDAYS, AND LEGAL HOLIDAYS EXCLUDED AFTER OPENING OF GENERAL BIDS. NO TELEPHONE OR TELEGRAPHIC BID, CHANGE IN BID OR WITHDRAWAL BID WILL BE RECEIVED OR RECOGNIZED. D) TELEFAX BIDS MAY BE RECEIVED AT OWNER'S OPTION. B1-11 EXAMINATION OF SITE A) THE CONTRACTOR SHALL EXAMINE THE SITE, DRAWINGS, SPECIFICATIONS, AND CONTRACT FORM FOR THE WORK PRIOR TO SUBMITTING PROPOSAL AND FULLY INFORM HIMSELF OF THE CONDITIONS UNDER WHICH THE WORK MUST BE COMPLETED AND ASSUME RESPONSIBILITY FOR ANY UNUSUAL AND UNFORESEEN DIFFICULTIES TO BE OVERCOME IN COMPLETING THE WORK. B) THE CONTRACTOR AND ALL SUBCONTRACTORS MUST VERIFY DIMENSIONS AND MEASUREMENTS OF ANY EXISTING CONDITIONS PRIOR TO ORDERING MATERIALS OR DOING WORK THAT REQUIRES COORDINATION WITH OTHER TRADES OR EXISTING CONDITIONS. NO CLAIM BASED ON DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE SHOWN ON DRAWINGS WILL BE CONSIDERED. B1-12 BOND: BIDDER TO WHOM CONTRACT IS AWARDED SHALL QUALIFY TO EXECUTE, AND SHALL EXECUTE A PERFORMANCE BOND AND LABOR AND MATERIAL PAYMENT BOND FOR 100% OF AMOUNT OF CONTRACT, IF DIRECTED BY OWNER. BOND PREMIUMS PAID BY OWNER. FORM UTILIZED SHALL BE CURRENT EDITION OF AIA FORM A-311. EXECUTE AND DELIVER BOND TO OWNER WITHIN FIFTEEN (15) DAYS AFTER SIGNING CONTRACT, IF BOND DEEMED NECESSARY. B1-13 SUBCONTRACTORS, SUPPLIERS, MATERIALS AND EQUIPMENT: LIST NAME, IN PLACES PROVIDED ON PROPOSAL FORM, ALL SUBCONTRACTORS, SUPPLIERS, MATERIALS AND EQUIPMENT REQUESTED ON WHOM OR WHICH BID IS BASED AND WHOM BIDDER INTENDS TO EMPLOY OR WHICH HE INTENDS TO USE. COMPLETE ALL SPACES IN FORM OF PROPOSAL. SEE SUPPLEMENTARY GENERAL CONDITIONS, ARTICLE 28. B1-14 BIDDING PROCEDURE A) SUBMIT BIDS USING APPROVED PROPOSAL FORMS, COPIES ARE AVAILABLE FROM POTBELLY REPRESENTATIVE. COMBINED PROPOSAL IS INVITED ON ENTIRE CONTRACT INCLUDING GENERAL CONTRACT, PLUMBING, HEATING, AIR CONDITIONING AND VENTILATING, AND ELECTRICAL. SUBMIT AS ONE TOTAL CONTRACT AMOUNT IN SPACE PROVIDED ON FORM OF PROPOSAL. SUBMIT PROPOSAL ON OWNER SUPPLIED "FORM OF PROPOSAL" UNDER THIS FORM, CONTRACT AMOUNT IF FIXED AND CONTRACTOR GUARANTEES A LIMIT OF CONSTRUCTION COST. B) BIDS BY INVITATION ONLY. OWNER RESERVES RIGHT TO REJECT ANY, OR ALL BIDS. C) BIDDERS AND THEIR PROPOSED SUBCONTRACTORS COMPETENCY AND RESPONSIBILITY WILL BE CONSIDERED IN MAKING AWARD. B1-15 UTILITY COMPANIES REGULATIONS COMPLY WITH REGULATIONS OF LOCAL UTILITY COMPANIES PRIOR TO SUBMISSION OF PROPOSAL. DETERMINE FROM EACH UTILITY COMPANY SUPPLYING SERVICE TO PROJECT ALL REQUIREMENTS AND INCLUDE COST OF SAME IN BID COST OF RELOCATION OF UTILITIES SERVICE LINES INTERFERING WITH CONSTRUCTION SHALL BE INCLUDED IN CONTRACTOR'S PROPOSAL. B1-07 EXAMINATION OF DOCUMENTS: BIDDERS EXAMINE ALL CONTRACT DOCUMENTS, INCLUDING ALL DRAWINGS AND SPECIFICATIONS FOR ALL DIVISIONS OF WORK AS WELL AS HIS OWN, NOTING PARTICULARLY ALL REQUIREMENTS WHICH AFFECT HIS WORK IN ANYWAY. FAILURE OF BIDDER TO ACQUAINT HIMSELF WITH QUANTITY AND CHARACTER OF WORK REQUIRED TO COMPLETE HIS DIVISION OF CONTRACT IN CONFORMITY WITH ALL REQUIREMENTS FOR PROJECT WILL NOT BE CONSIDERED AS BASIS FOR EXTRA COMPENSATION. B1-08 INQUIRIES: SHOULD BIDDER FIND DISCREPANCIES OR OMISSIONS IN DRAWINGS OR SPECIFICATIONS, OR HAVE DOUBT OF THEIR MEANING, NOTIFY ARCHITECT OR POTBELLY REPRESENTATIVE AT ONCE. ARCHITECT WILL ISSUE WRITTEN INSTRUCTIONS TO ALL BIDDERS REGARDING SAME. NEITHER ARCHITECT, NOR POTBELLY REPRESENTATIVE WILL BE RESPONSIBLE FOR ANY ORAL INSTRUCTIONS. INQUIRIES IN REGARD TO BID SHALL BE MADE MINIMUM OF ONE (1) WEEK PRIOR TO BID RECEIPT DATE. B1-09 CONTRACT AWARD: OWNER WILL CONSIDER COMPETENCY AND RESPONSIBILITY OF BIDDERS AND SUBCONTRACTORS IN MAKING AWARD. OWNER ARTICLE 2 - DEFINITIONS: NOTICES: CONTRACT DOCUMENTS A) OWNER-CONTRACTOR AGREEMENT. B) GENERAL CONDITIONS: C) SUPPLEMENTARY GENERAL CONDITIONS: (IN SPECIFICATIONS, OF WHICH THIS IS A PART.) D) GENERAL SPECIFICATIONS. E) DRAWINGS AND ISSUED ADDENDA. OWNER WHERE REFERENCED IN THE SPECIFICATIONS, THE "OWNER" OR "OWNER'S REPRESENTATIVE" SHALL MEAN "THE OWNER'S DIRECTOR OF CONSTRUCTION," AS DESIGNATED IN THE EXECUTED OWNER-CONTRACTOR AGREEMENT. POTBELLY SANDWICH SHOP 222 MERCHANDISE MART PLAZA 23RD FLOOR CHICAGO, ILLINOIS 60654 312.951.0600 ARCHITECT AS NAMED ON COVER SHEET CONTRACTOR AS NAMED IN CONSTRUCTION CONTRACT, UNLESS OTHERWISE DEFINED, SUCH AS GENERAL CONTRACTOR OR ELECTRICAL CONTRACTOR, TERM CONTRACTOR SHALL BE UNDERSTOOD TO MEAN ANY CONTRACTOR OR CONTRACTORS WHO HAVE ENTERED INTO SEPARATE CONTRACT WITH OWNER. B1-16 CODES AND RESTRICTIONS THIS BUILDING DESIGN IS BASED UPON LOCAL BUILDING CODES. SHOULD PROVISIONS OF PREVAILING LOCAL BUILDING AUTHORITIES OR CODES GOVERNING AREA FOR CONSTRUCTION OF THIS BUILDING DIFFER FROM THOSE PROVISIONS OF THE LOCAL CODE, IT WILL BE THE RESPONSIBILITY OF BIDDER TO ADVISE ARCHITECT IMMEDIATELY OF SAME AND TO BID PROJECT ACCORDING TO GOVERNING CODES. AN ADDENDUM WILL BE ISSUED INSTRUCTING ALL BIDDERS. GENERAL CONTRACTOR AS NAMED IN CONSTRUCTION CONTRACT. CONTRACTOR FOR ALL OF WORK EXCEPT THOSE PARTS FOR WHICH OWNER HAS CONTRACTED SEPARATELY. CONTRACT FORMS REQUEST FOR QUOTATION LETTER OR FORM ISSUED AFTER AWARD OF CONTRACT REQUESTING CHANGE OR AMENDMENT OF CONTRACT DOCUMENTS. CHANGE ORDER IS ISSUED, FROM THIS INFORMATION. DIVISION B - CONSTRUCTION CONTRACT FORM: FURNISHED BY THE GENERAL CONTRACTOR. UNLESS OTHERWISE AGREEABLE TO THE OWNER, USE AIA 107 AGREEMENT BETWEEN OWNER AND CONTRACTOR FOR A PROJECT OF LIMITED SCOPE, MODIFIED TO INCORPORATE THE GENERAL AND SUPPLEMENTARY CONDITIONS HEREIN.. PERFORMANCE BOND: PERFORMANCE AND MATERIALS BOND SHALL BE EXECUTED ON AMERICAN INSTITUTE OF ARCHITECTS PERFORMANCE BOND. A.I.A. DOCUMENT NUMBER 311, CURRENT EDITION. THIS FORM IS AVAILABLE FOR INSPECTION IN ARCHITECT'S OFFICE AND IS NOT BOUND WITHIN THIS SET OF SPECIFICATIONS. BOND SHALL BE IN THE AMOUNT OF 100% OF CONTRACT; BOND TO BE PAID BY OWNER, IF REQUIRED. B) CONTRACTOR LIABLE AND RESPONSIBLE FOR MAKING, AT HIS OWN EXPENSE, ANY AND ALL REPAIRS REQUIRED BY REASON OF DAMAGE RESULTING FROM PERFORMANCE, NON-PERFORMANCE OR IMPROPER PERFORMANCE OF WORK PROVIDED; HOWEVER, THAT CONTRACTOR SHALL NOT REPAIR ANY DAMAGE DIRECTLY CAUSED SOLELY BY ACTS OF OWNER. IF REPAIRS ARE NOT PROMPTLY MADE, OWNER MAY MAKE REPAIRS AND DEDUCT COSTS FROM AMOUNTS OTHERWISE DUE TO CONTRACTOR AT THAT TIME OR BILL CONTRACTOR FOR SAID COSTS. C) CONTRACTOR TAKE WHATEVER PRECAUTIONS ARE NECESSARY TO PROTECT PREMISES BELONGING TO OWNER COMPRISING OR BEING IN VICINITY THEREOF, SO AS TO SAFEGUARD ALL STRUCTURES, FIXTURES, FURNISHINGS AND EQUIPMENT LOCATED THEREON. PROTECT ALL ADJACENT PROPERTY AND PROPERTY IN VICINITY FROM DAMAGE. HOLD OWNER HARMLESS FROM ANY DAMAGES. ARTICLE 6 - CONTRACTOR'S RESPONSIBILITY CONTRACTOR AGREES TO INDEMNIFY OWNER AGAINST ANY AND ALL CLAIMS, LOSS, DAMAGE, COSTS AND EXPENSE ARISING FROM INJURY TO OR DEATH OF PERSONS OR DAMAGE TO PROPERTY AND EMPLOYEES OF OWNER, OCCURRING, WHOLLY OR IN PART, AS RESULT OF WORK DONE OR OMITTED, OR CONTRACTED TO BE DONE; BUT, NOT DONE BY CONTRACTOR OR HIS SUBCONTRACTORS, IF ANY, OR EMPLOYEES OR AGENTS OR INVITEES OF CONTRACTOR OR ANY SUBCONTRACTORS, REGARDLESS OF WHETHER ANY SUCH INJURY TO OR DEATH OF PERSONS OR DAMAGE TO OR DESTRUCTION OF PROPERTY IS DUE OR CLAIMED TO BE DUE, IN WHOLE OR IN PART, TO ANY NEGLIGENCE OR FAULT OF OWNER OR HIS EMPLOYEES, AGENTS OR INVITEES, EXCEPT CLAIMS, LOSS, DAMAGE, COSTS OR EXPENSE RESULTING SOLELY FROM THE WILLFUL ACTION OF OWNER. ADDENDUM LETTER OR FORM CLARIFYING, AMENDING, OR INTERPRETING CONTRACT DOCUMENTS ISSUED BEFORE RECEIPT OF BIDS. CHANGE ORDER LETTER OR FORM AUTHORIZING CHANGES IN THE CONTRACT DOCUMENTS EXECUTED PER THE GENERAL CONDITIONS. FIELD ORDER LETTER OR FORM AUTHORIZING CHANGES WHICH DO NOT CHANGE THE CONTRACT AMOUNT. WORK ALL THAT WHICH SHALL BE DONE, PER ARTICLE 1 OF GENERAL CONDITIONS. OWNER NOT RESPONSIBLE IN ANY MANNER FOR THE PROPERTY OF CONTRACTOR, CONTRACTOR'S EMPLOYEES, OR SUBCONTRACTORS OR SUBCONTRACTOR'S EMPLOYEES. ARTICLE 7 - PAYMENTS BY CONTRACTOR CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS REQUIRED FOR WORK AND SHALL PAY FOR ALL FEES, TAXES, ROYALTIES, RENTS, PENALTIES AND CHARGES AS MAY BE REQUIRED FOR WORK EXCEPT AS HEREINAFTER SPECIFICALLY PROVIDED. OWNER RESERVES RIGHT TO TAKE OUT ANY, OR ALL PERMITS. THESE PAYMENTS SHALL BE IN ADDITION TO ANY PAYMENTS TO OWNER UNDER ANY TERMS, CONDITION, OR PROVISION OF CONTRACT DOCUMENTS. OWNER WILL PAY ALL REAL ESTATE ASSESSMENTS AND REAL ESTATE TAXES. SIGN PERMIT SHALL BE OBTAINED BY SIGN CONTRACTOR AT HIS EXPENSE. SPECIAL INSPECTIONS REQUIRED UNDER PROVISIONS OF BUILDING CODE OR UTILITY COMPANY REGULATIONS ARRANGED AND PAID FOR BY CONTRACTOR. ARTICLE 9 - MEASUREMENTS BEFORE ANY MATERIAL IS FABRICATED, CONTRACTOR AND EACH SUBCONTRACTOR SHALL TAKE ALL NECESSARY MEASUREMENTS AND LAY OUT WORK INCLUDED IN HIS CONTRACT, AND SHALL BE RESPONSIBLE FOR PROPER FITTING AND ACCURACY. ARTICLE 10 - MATERIALS PLACE ORDERS FOR MATERIALS AND EQUIPMENT TO BE EMPLOYED IN WORK; OTHER THAN THOSE DESIGNATED FURNISHED BY OWNER, AS SOON AS POSSIBLE AFTER AWARD OF CONTRACT. CONTRACTOR SHALL KEEP OWNER, ARCHITECT, AND POTBELLY REPRESENTATIVE INFORMED AS TO AVAILABILITY OF ALL SPECIFIED MATERIALS AND EQUIPMENT, ADVISE THEM PROMPTLY IN WRITING OF ALL ORDERS PLACED, AND OF SUCH MATERIALS AND EQUIPMENT AS MAY NOT BE OBTAINABLE FOR PURPOSES OF CONTRACT, WHETHER DUE TO CONDITIONS OF MARKET OR OTHER LIMITING AND GOVERNING FACTORS. ARTICLE 3 - ABBREVIATIONS ARTICLE 11 - WARRANTY OF TITLE DIVISION C - GENERAL CONDITIONS GENERAL CONDITIONS OF CONTRACT FOR CONSTRUCTION - CONSTRUCTION MANAGER AS ADVISOR, AS PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS, AIA DOCUMENT NUMBER A-232, 2009 EDITION, SHALL APPLY TO GENERAL CONTRACT AS WELL AS ALL SUBCONTRACTS, EXCEPT AS SAID GENERAL CONDITIONS MAY BE ABROGATED, AMPLIFIED, MODIFIED, OR NULLIFIED BY SUPPLEMENTARY GENERAL CONDITIONS, CONTAINED IN THESE SPECIFICATIONS, SAID GENERAL CONDITIONS AND SAID SUPPLEMENTARY GENERAL CONDITIONS HAVE BEEN CAREFULLY READ AND CONSIDERED PART OF THE SPECIFICATIONS. SUPPLEMENTARY GENERAL CONDITIONS A) CONTRACTOR PROVIDES ALL ITEMS, ARTICLES, MATERIALS, OPERATIONS OR METHODS INDICATED ON PLANS, SECTIONS AND/OR DETAILS, INCLUDING ALL LABOR, MATERIALS, EQUIPMENT AND INCIDENTALS REQUIRED OR NECESSARY FOR THEIR COMPLETION. B) CALL ERRORS OR INCONSISTENCIES IN DRAWINGS OR SPECIFICATIONS TO THE ATTENTION OF THE ARCHITECT OR POTBELLY REPRESENTATIVE FOR PROPER ADJUSTMENT. DO NOT PROCEED WITH WORK IN CASES OF UNCERTAINTY. C) CONTRACTOR AGREES THAT WORK HEREIN DESCRIBED SHALL BE COMPLETE IN EVERY DETAIL, EVEN THOUGH EVERY ITEM NECESSARILY INVOLVED IS NOT PARTICULARLY MENTIONED. CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS NECESSARY FOR COMPLETION OF WORK DESCRIBED IN CONTRACT DOCUMENTS, AND NOT AVAIL HIMSELF OF ANY MANIFESTLY UNINTENTIONAL ERROR OR OMISSION SHOULD SUCH EXIST. D) SHOULD CONTRACT DOCUMENTS DISAGREE AS TO QUALITY OR QUANTITY OF WORK, PROVIDE BETTER QUALITY OR GREATER QUANTITY UNLESS INSTRUCTED OTHERWISE BY ARCHITECT IN WRITING. E) CERTAIN SPECIFICATIONS AND CERTAIN OF OTHER CONTRACT DOCUMENTS, INCLUDING THESE GENERAL CONDITIONS, ARE OF SIMPLIFIED TYPE AND INCLUDE INCOMPLETE SENTENCES. OMISSION OF WORDS OR PHRASES, SUCH AS "THE CONTRACTOR SHALL", "IN CONFORMITY THEREWITH", "SHALL BE", "AS NOTED", "A", "AN", "THERE", AND "ALL" ARE INTENTIONAL. OMITTED WORDS SHALL BE SUPPLIED INFERENCE IN SAME MANNER AS THEY ARE WHEN A NOTE OCCURS ON DRAWINGS, WORDS "SHALL BE" OR "SHALL BE SUPPLIED" BY INFERENCE PARTICULARLY WHEN A COLON OR HYPHEN IS USED WITHIN SENTENCE OR PHRASES. REFERENCE TO TECHNICAL SOCIETY'S ORGANIZATION BODIES OR DOCUMENTS IS MADE IN SPECIFICATIONS IN ACCORDANCE WITH FOLLOWING ABBREVIATIONS: AIA AMERICAN INSTITUTE OF ARCHITECTS ACI AMERICAN CONCRETE INSTITUTE AIEE AMERICAN INSTITUTE OF ELECTRICAL ENGINEERS AHJ AUTHORITY HAVING JURISDICTION AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION ASA AMERICAN STANDARDS ASSOCIATION ASLA AMERICAN SOCIETY OF LANDSCAPE ARCHITECTS ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AWI ARCHITECTURAL WOODWORK INSTITUTE AWSC AMERICAN WELDING SOCIETY CODE FS FEDERAL SPECIFICATIONS ICC INTERNATIONAL CODE COUNCIL NAAMM NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS NFPA NATIONAL FIRE PROTECTION ASSOCIATION NBS NATIONAL BUREAU OF STANDARDS NEC NATIONAL ELECTRICAL CODE SJI STEEL JOIST INSTITUTE SPR SIMPLIFIED PRACTICE RECOMMENDATION UL UNDERWRITER'S LABORATORIES, INC. BOCA BUILDING OFFICIALS CODE ASSOCIATION UBC UNIFORM BUILDING CODE SBCCI STANDARD BUILDING CODE CONGRESS INTERNATIONAL NO MATERIALS, SUPPLIES, OR EQUIPMENT INCORPORATED IN WORK SHALL BE PURCHASED SUBJECT TO ANY CHATTEL MORTGAGE OR UNDER A CONDITIONAL SALE OR OTHER AGREEMENT BY WHICH AN INTEREST THEREIN, OR IN ANY PART THEREOF, IS RETAINED BY SELLER, SUPPLIER, OR MANUFACTURER. ARTICLE 12 - MOVING OF MATERIALS IF IT BECOMES NECESSARY DURING PROGRESS OF WORK TO MOVE MATERIALS WHICH ENTER INTO CONSTRUCTION, OR EQUIPMENT TEMPORARILY PLACED, CONTRACTOR FURNISHING SAME SHALL, WHEN DIRECTED BY POTBELLY, MOVE THEM WITHOUT COST TO OWNER. ARTICLE 13 - WORKMEN AND WORKMANSHIP A) CONTRACTOR MAINTAIN ORDER AND DISCIPLINE AMONG WORKMEN AT ALL TIMES. B) WORKMANSHIP: ONLY ARTISANS AND MECHANICS QUALIFIED THROUGH EXPERIENCE IN THEIR RESPECTIVE BRANCHES SHALL EXECUTE OR PERFORM WORK. ARCHITECT, OR POTBELLY REPRESENTATIVE IS NOT ON JOB SITE AT ALL TIMES; HOWEVER, WORK INSTALLED CONTRARY TO CONTRACT DOCUMENTS SHALL BE REMOVED AND REPLACED WITHOUT DELAY, IN CONFORMITY WITH CONTRACT DOCUMENTS WHEN DIRECTED BY ARCHITECT, OR POTBELLY REPRESENTATIVE WITHOUT ADDITIONAL COST TO OWNER. C) WORKMEN NOT COMPLYING WITH PROVISIONS OF CONTRACT DOCUMENTS SHALL BE IMMEDIATELY REMOVED BY CONTRACTOR FROM ANY PREMISES BELONGING TO OWNER UPON NOTICE OF ARCHITECT OR POTBELLY REPRESENTATIVE. ARTICLE 4 - CODES AND STANDARDS ARTICLE 14 - PROSECUTION OF WORK MATERIAL SUPPLIERS SUBMIT EVIDENCE, IF REQUESTED, MATERIAL IN QUESTION COMPLIES WITH APPLICABLE CURRENT CODES AND STANDARDS AS REFERRED TO IN SPECIFICATIONS. ARTICLE 5 - DAMAGE RESULTING FROM WORK A) GENERAL CONTRACTOR/CONTRACTOR IS SOLELY RESPONSIBLE FOR EXPENSES INCURRED OR DAMAGE CAUSED BY DEFECTIVE OR ILLTIMED WORK PERFORMED OR WHICH HE FAILS TO PERFORM PER HIS CONTRACT. BEFORE STARTING AND INTERMITTENTLY AS WORK PROGRESSES, CONTRACTOR AND SUBCONTRACTORS EXAMINE WORK INSTALLED BY OTHERS INSOFAR AS IT APPLIES TO HIS WORK AND PROMPTLY NOTIFY ARCHITECT OR POTBELLY REPRESENTATIVE IF CONDITIONS EXIST THAT PREVENT HIM GIVING SATISFACTORY RESULTS. IT IS DUTY OF CONTRACTOR TO NOTIFY VARIOUS SUBCONTRACTORS WHEN THEIR PRESENCE IS REQUIRED, EXPEDITE FLOW OF MATERIALS AND SECURE NECESSARY INSPECTIONS. CONTRACTOR SHALL REQUIRE THAT ALL SUBCONTRACTORS HAVE COMPETENT SUPERVISOR ON SITE WHENEVER HIS WORK IS BEING PERFORMED. CONTRACTOR SHALL GIVE REASONABLE NOTICE TO ARCHITECT AND POTBELLY REPRESENTATIVE WHEN HIS PRESENCE IS REQUIRED FOR SPECIAL CONSULTATIONS, EXAMINATIONS, OR DECISIONS. ARTICLE 15 - EXAMINATION WORK, OPERATION AND MAINTENANCE MANUALS PERTAINING TO ALL MECHANICAL EQUIPMENT FURNISHED AND/OR INSTALLED UNDER CONTRACT. FAILURE TO FURNISH SUCH MANUALS WITHIN ALLOTTED TIME LIMIT WILL CAUSE SAID CONTRACTOR TO BE LIABLE FOR DAMAGES RESULTING FROM MISUSE OF SAID EQUIPMENT. ARTICLE 26 - NOTICES ARTICLE 16 - PROTECTION OF MATERIALS A) PROTECT PRE FINISHED MATERIALS OR MATERIALS FINISHED IN PLACE WHEN INSTALLED BEFORE COMPLETION OF WORK FROM DAMAGE UNTIL ACCEPTANCE OF PROJECT. REPLACE MATERIALS DAMAGED BEFORE OR AFTER INSTALLATION WITH NEW AND UNDAMAGED FINISHED MATERIALS. REFINISH, OR REPLACE AND FINISH, MATERIALS AFTER INSTALLATION WHICH ARE DAMAGED AS DIRECTED. ADDITIONAL CHARGES ARE NOT HONORED BY OWNER FOR REPLACEMENT OR REPAIR OF DAMAGED MATERIALS. B) PROVIDE SECURITY AND FACILITIES TO PROTECT WORK, AND EXISTING FACILITIES, AND OWNER'S OPERATIONS FROM UNAUTHORIZED ENTRY, VANDALISM, OR THEFT. ARTICLE 17 - NO WAIVER BY OWNER FAILURE OF OWNER IN ONE OR MORE INSTANCES TO INSIST UPON STRICT PERFORMANCE OF ANY TERMS OF CONTRACT OR TO EXERCISE ANY OPTION HEREIN CONFERRED, SHALL NOT BE CONSTRUED AS WAIVER OR RELINQUISHMENT TO ANY EXTENT OF RIGHT TO ASSERT OR RELY UPON ANY SUCH TERMS OR OPTION ON ANY FUTURE OCCASION. ARTICLE 18 - SUSPENSION OF WORK CONTRACTOR SHALL BEAR ALL LOSSES OCCURRING BY REASON OF THEFT OR LOSS, OR DAMAGE, REGARDLESS OF CAUSE, TO: A) ALL MATERIALS, SUPPLIES, EQUIPMENT AND APPARATUS OWNED, USED OR FURNISHED, REGARDLESS OF WHETHER OF NOT SAID MATERIALS, SUPPLIES, EQUIPMENT OR APPARATUS ARE INCLUDED IN ITEMS TO BE FURNISHED OR USED HEREUNDER OR TO BE INCORPORATED IN WORK, PRIOR TO WORK'S COMPLETIONS. B) ALL OF CONTRACTOR'S TOOLS, MACHINERY, EQUIPMENT, MATERIALS, SUPPLIES, APPLIANCE, SHORING, SCAFFOLDING, FALSE WORK AND SHED AND PERSONAL PROPERTY OF CONTRACTOR'S EMPLOYEES. ARTICLE 8 - SPECIAL INSPECTIONS GENERAL CONDITIONS ARTICLE 1 - DRAWINGS AND SPECIFICATIONS B1-06 EXAMINATION OF PREMISES: PRIOR TO SUBMITTING PROPOSAL, BIDDER WILL EXAMINE PREMISES AND SATISFY HIMSELF AS TO CONDITIONS UNDER WHICH HE SHALL BE OBLIGED TO OPERATE IN PERFORMING WORK, OR THOSE CONDITIONS WHICH AFFECT HIS WORK. BIDDERS VISIT AND EXAMINE SITE TO INFORM THEMSELVES OF SITE CHARACTERISTICS AND CIRCUMSTANCES AFFECTING COST OF WORK AND TIME REQUIRED FOR EXECUTION OF CONTRACT. BIDDERS WHOLLY RESPONSIBLE FOR ERRORS AFFECTING COST OF WORK AND TIME REQUIRED FOR EXECUTION, AS WELL AS ERRORS WHICH MAY OCCUR IN THEIR PROPOSAL DUE TO FAILURE TO MAKE SUCH VISITS AND EXAMINATIONS. F) WORD "PROVIDE" SHALL BE UNDERSTOOD TO MEAN "FURNISH" INSTALL AND (IF APPLICABLE) PLACE IN OPERATION" UNLESS OTHERWISE STATED. WORDS "DIRECTED", "SELECTED", "APPROVED", "REQUIRED", "PERMITTED", "ACCEPTED", SHALL BE UNDERSTOOD TO MEAN DIRECTION, SELECTION, APPROVAL, REQUIREMENTS OR PERMISSION, RESPECTIVELY OF THE OWNER'S DIRECTOR OF CONSTRUCTION,, UNLESS OTHERWISE STATED. G) SPECIFICATIONS ARE ARRANGED IN SECTIONS, BUT SUCH SEGREGATION SHALL NOT BE CONSIDERED AS LIMITING WORK REQUIRED BY ANY TRADE. DIVISION OF WORK SHALL BE THE RESPONSIBILITY OF CONTRACTOR. H) DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY. EXCEPT AS FOLLOWS, WHAT IS CALLED FOR BY ONE SHALL BE CONSIDERED AS CALLED FOR BY BOTH. 1) WHERE FINISHES NOT INDICATED ON THE DRAWING FINISH PLANS, ELEVATIONS, OR NOTES ARE INDICATED IN THE FINISH LEGEND, SUCH FINISHES SHALL NOT BE REQUIRED. 2) WHERE HARDWARE NOT REFERENCED ON THE DOOR SCHEDULE IS INDICATED IN HARDWARE GROUP SCHEDULE, SUCH HARDWARE SHALL NOT BE REQUIRED. 3) ALL MATERIALS, PROCEDURES, AND COMPLIANCE REQUIREMENTS REASONABLY NECESSARY FOR CONSTRUCTION OF A COMPLETE AND FUNCTIONING FACILITY IN ACCORDANCE WITH DESIGN INTENT SHALL BE REQUIRED, REGARDLESS OF EXTENT OF DOCUMENTATION. IF WHOLE OR PART OF WORK IS SUSPENDED CONTRACTOR SHALL, AT HIS OWN EXPENSE, COVER, SECURE AND PROTECT ALL PARTS OF HIS WORK THAT MIGHT BE INJURED FROM ANY CAUSE. ARTICLE 19 - STOPPAGE OF WORK IN EVENT OWNER IS PERMANENTLY ENJOINED OR OTHERWISE STOPPED FROM COMPLETING THIS CONTRACT, OWNER IS LIABLE TO CONTRACTOR FOR ONLY WORK ACTUALLY PERFORMED AND MATERIALS AT SITE LESS SALVAGE VALUE THEREOF. SCHEDULE OF VALUES OF CONTRACT SUBMITTED AT TIME CONTRACT IS SIGNED WILL BE USED AS A BASIS OF SETTLEMENT. ARTICLE 20 - CLEANING UP A) EACH CONTRACTOR, UPON COMPLETION OF HIS WORK, COLLECT AND REMOVE ALL RUBBISH, SURPLUS MATERIALS, TOOLS, AND SCAFFOLDING. KEEP PREMISES NEAT AND ORDERLY BY PERIODIC REMOVAL AND CLEANUP. REMOVE CRATES AND CARTONS IN WHICH MATERIALS, EQUIPMENT OR FIXTURES ARE RECEIVED DAILY. B) IF, IN OPINION OF ARCHITECT, POTBELLY REPRESENTATIVE, OR GENERAL CONTRACTOR, NEATNESS IS NOT MAINTAINED, POTBELLY REPRESENTATIVE OR GENERAL CONTRACTOR MAY HAVE AREA CLEANED AND CHARGE COSTS TO RESPONSIBLE CONTRACTORS. C) AT COMPLETION OF BUILDING OR ANY PART THEREOF, GENERAL CONTRACTOR, IN ADDITION TO REMOVAL OF ACCUMULATED RUBBISH, SHALL REPLACE ANY BROKEN GLASS, REMOVE STAINS, SPOTS AND MARKS FROM FINISH WORK AND HARDWARE. D) REMOVE ALL STICKERS AND LEAVE BUILDING IN A CLEAN CONDITION. ARTICLE 21 - GUARANTEE UNLESS OTHERWISE SPECIFIED, CONTRACTOR GUARANTEES ALL MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE OF BUILDING, AND SHALL REPLACE OR SATISFACTORILY REPAIR, WITHOUT COST TO OWNER OR INTERFERENCE WITH OWNER'S OPERATION, ANY DEFECTIVE WORKMANSHIP OR MATERIALS. ADDITIONAL REPLACEMENTS OR REPAIRS, WITHOUT LIMITATION, SHALL BE MADE BY CONTRACTOR WITHOUT COST TO OWNER UNTIL ALL DEFECTIVE WORKMANSHIP OR MATERIALS HAVE BEEN CORRECTED AND THE WORK COMPLETED IN ACCORDANCE WITH CONTRACT DOCUMENTS EVEN IF THE ONE (1) YEAR PERIOD ABOVE SPECIFIED HAS EXPIRED IF OWNER HAS GIVEN CONTRACTOR NOTICE OR ORIGINAL FAILURE OF COMPLIANCE WITH CONTRACT DOCUMENTS IS PRIOR TO EXPIRATION OF SAID PERIOD. ARTICLE 22 - JOB MEETINGS 1. PRECONSTRUCTION MEETING: THE OWNER WILL ADMINISTER PRECONSTRUCTION MEETING FOR EXECUTION OF THE OWNER-CONTRACTOR AGREEMENT (IF NOT PREVIOUSLY COMPLETED) AND EXCHANGE OF PRELIMINARY SUBMITTALS. AGENDA SHALL INCLUDE THE FOLLOWING. A. IDENTIFICATION AND INTRODUCTION OF OWNER, ARCHITECT, DIRECTOR OF CONSTRUCTION, CONTRACTOR, PRINCIPLE SUBCONTRACTORS, LANDLORD, AND OTHER KEY PERSONNEL B. CLARIFICATION RESPONSIBILITIES IN USE OF SITE. C. PROJECT SCHEDULE, INCLUDING SCHEDULE FOR CRITICAL SUBMITTALS, RESUBMITTALS, PAY APPLICATIONS, TESTING AND INSPECTIONS, AND PROGRESS MEETINGS. D. QUALITY ASSURANCE. E. SUBMITTAL REQUIREMENTS, INCLUDING FORMAT, RECIPIENTS, REVIEW PROCESSES, AND TURNAROUND. F. MOCK-UPS: SCHEDULE, TYPE, LOCATION, APPROVAL CRITERIA, AND REMOVAL. G. TARGETS AND VERIFICATION OF SUSTAINABLE CONSTRUCTION MATERIALS AND PRACTICES. H. TIMING, NOTIFICATION, SUBMITTAL REQUIREMENTS, HANDLING, AND COORDINATION OF OWNER FURNISHED ITEMS. I. COMMUNICATION AND RECORDKEEPING. 2. GENERAL CONTRACTOR SCHEDULE SEMIMONTHLY PROGRESS MEETING BETWEEN HIMSELF, SEPARATE CONTRACTORS, AND MAJOR SUBCONTRACTORS. NOTIFY POTBELLY REPRESENTATIVE OF TIME OF MEETING WHICH SHALL BE SAME HOUR AND DAY OF WEEK FOR DURATION OF WORK. GENERAL CONTRACTOR MUST TAKE AND DISTRIBUTE MINUTES OF ALL MEETINGS, TO SUBCONTRACTORS, SEPARATE CONTRACTORS AND POTBELLY REPRESENTATIVE. ARTICLE 23 - MATERIALS AND SUBCONTRACTORS CONTRACTOR EMPLOY SUBCONTRACTORS AND FURNISH MATERIALS NAMED IN PROPOSAL, IF APPROVED BY OWNER. ARTICLE 24 - SCOPE OF AGREEMENT EXECUTION OF ABOVE MENTIONED OWNER-CONTRACTOR AGREEMENT, BOTH OWNER AND CONTRACTOR AGREE TO BE BOUND BY EACH AND EVERY TERM AND CONDITION OF AFORESAID CONTRACT DOCUMENTS. ARTICLE 25 - MECHANICAL EQUIPMENT MANUALS CONTRACTOR DELIVER TO OWNER WITHIN ONE WEEK OF COMPLETION OF CONTRACTOR SEND WRITTEN NOTICES INDICATING NATURE AND SCOPE OF WORK TO ALL PROPERTY OWNERS IN VICINITY OF WORK WHOSE PROPERTY MIGHT IN ANYWAY BE AFFECTED BY WORK UNDER THIS CONTRACT. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM ARTICLE 27 - SUBCONTRACTORS LIST OF SUBCONTRACTORS REFERRED TO UNDER ARTICLE 5.2.1 OF GENERAL CONDITIONS OF CONTRACT SHALL INCLUDE EACH SUBCONTRACTOR'S ADDRESS AND TELEPHONE NUMBER. A R 4 0 4 S. ARTICLE 28 - INSURANCE REQUIREMENT IN ADDITION TO THOSE CALLED FOR IN GENERAL CONDITIONS A) GENERAL: THESE REQUIREMENTS ARE INCLUDED IN THE BID DOCUMENTS. ARTICLE 29 - INSPECTING AND TESTING LABORATORY SERVICES A) OWNER WILL APPOINT, EMPLOY, AND PAY FOR SPECIFIED SERVICES OF AN INDEPENDENT FIRM TO PERFORM INSPECTING AND TESTING THAT IS SPECIFIED AS OWNER'S RESPONSIBILITIES. THE CONTRACTOR WILL APPOINT, EMPLOY AND PAY FOR SPECIFIED SERVICES OF AN INDEPENDENT FIRM TO PERFORM INSPECTION AND TESTING THAT IS SPECIFIED AS CONTRACTOR'S RESPONSIBILITY. B) THE INDEPENDENT FIRM WILL PERFORM INSPECTIONS, TESTS, AND OTHER SERVICES SPECIFIED IN INDIVIDUAL SPECIFICATION SECTIONS AND AS REQUIRED BY THE ARCHITECT/ENGINEER OR THE OWNER. C) INSPECTING, TESTING, AND SOURCE QUALITY CONTROL MAY OCCUR ON OR OFF THE PROJECT SITE. PERFORM OFF-SITE INSPECTING OR TESTING AS REQUIRED BY THE ARCHITECT/ENGINEER OR THE OWNER. D) REPORTS WILL BE SUBMITTED BY THE INDEPENDENT FIRM TO THE ARCHITECT/ENGINEER,IN DUPLICATE, INDICATING OBSERVATIONS AND RESULTS OF TESTS AND INDICATING COMPLIANCE OR NONCOMPLIANCE WITH CONTRACT DOCUMENTS. WRITTEN INSPECTION TEST REPORTS SHALL INCLUDE: 1. TEST AGENCY NAME 2. DATES AND LOCATIONS OF SAMPLES, TESTS, OR INSPECTIONS. 3. NAME OF INDIVIDUALS PRESENT. 4. COMPLETE INSPECTION OR TEST DATA. 5. TEST RESULTS AND INTERPRETATIONS. 6. RECOMMENDATIONS. E) COOPERATE WITH INDEPENDENT FIRM; FURNISH SAMPLES OF MATERIALS, DESIGN MIX, EQUIPMENT, TOOLS, STORAGE, SAFE ACCESS, AND ASSISTANCE BY INCIDENTAL LABOR AS REQUESTED. 1. NOTIFY ARCHITECT/ENGINEER AND INDEPENDENT FIRM FORTY EIGHT (48) HOURS PRIOR TO EXPECTED TIME FOR OPERATIONS REQUIRING SERVICES. 2. MAKE ARRANGEMENTS WITH INDEPENDENT FIRM AND PAY FOR ADDITIONAL SAMPLES AND TESTS REQUIRED FOR CONTRACTOR'S USE. F) TESTING OR INSPECTING DOES NOT RELIEVE CONTRACTOR TO PERFORM WORK TO CONTRACT REQUIREMENTS. G) RETESTING REQUIRED BECAUSE OF NON-CONFORMANCE TO SPECIFIED REQUIREMENTS SHALL BE PERFORMED BY THE SAME INDEPENDENT FIRM ON INSTRUCTIONS BY THE ARCHITECT/ENGINEER. PAYMENT FOR RETESTING WILL BE CHARGED TO THE CONTRACTOR BY DEDUCTING INSPECTING OR TESTING CHARGES FROM THE CONTRACT SUM/PRICE. ARTICLE 30 - SUBSTITUTIONS A) ARCHITECT/ENGINEER WILL CONSIDER REQUESTS FOR SUBSTITUTIONS ONLY WITHIN FIFTEEN DAYS AFTER DATE ESTABLISHED IN NOTICE TO PROCEED. B) SUBSTITUTIONS MAY BE CONSIDERED WHEN A PRODUCT BECOMES UNAVAILABLE THROUGH NO FAULT OF THE CONTRACTOR. C) DOCUMENT EACH REQUEST WITH COMPLETE DATA SUBSTANTIATING COMPLIANCE OF PROPOSED SUBSTITUTION WITH CONTRACT DOCUMENTS. D) A REQUEST CONSTITUTES A REPRESENTATION THAT THE CONTRACTOR: 1. HAS INVESTIGATED PROPOSED PRODUCT AND DETERMINED THAT IT MEETS OR EXCEEDS THE QUALITY LEVEL OF THE SPECIFIED PRODUCT. 2. WILL PROVIDE THE SAME WARRANTY FOR THE SUBSTITUTION AS FOR THE SPECIFIED PRODUCT. 3. WILL COORDINATE INSTALLATION AND MAKE CHANGES TO OTHER WORK WHICH MAY BE REQUIRED FOR THE WORK TO BE COMPLETE WITH NO ADDITIONAL COST TO OWNER. WHICH MAY SUBSEQUENTLY BECOME APPARENT. 4. WAIVES CLAIMS FOR ADDITIONAL COSTS OR TIME EXTENSION 5. WILL REIMBURSE OWNER FOR REVIEW OR REDESIGN SERVICES ASSOCIATED WITH PRE-APPROVAL BY AUTHORITIES. E) SUBSTITUTIONS WILL NOT BE CONSIDERED WHEN THEY ARE INDICATED OR IMPLIED ON SHOP DRAWING OR PRODUCT DATA SUBMITTALS, WITHOUT SEPARATE WRITTEN REQUEST, OR WHEN ACCEPTANCE WILL REQUIRE REVISION TO THE CONTRACT DOCUMENTS. F) SUBSTITUTION SUBMITTAL PROCEDURE: 1. SUBMIT THREE COPIES OF REQUEST FOR SUBSTITUTION FOR CONSIDERATION. LIMIT EACH REQUEST TO ONE PROPOSED SUBSTITUTION. 2. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND CERTIFIED TEST RESULTS ATTESTING TO THE PROPOSED PRODUCT EQUIVALENCE. BURDEN OF PROOF IS ON PROPOSER. 3. THE ARCHITECT/ENGINEER WILL NOTIFY CONTRACTOR IN WRITING OF DECISION TO ACCEPT OR REJECT REQUEST. C Wells H I S t ., T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 ARTICLE 31 - CLOSEOUT PROCEDURES A) SUBMIT WRITTEN CERTIFICATION THAT CONTRACT DOCUMENTS HAVE BEEN REVIEWED, WORK HAS BEEN INSPECTED, AND THAT WORK IS COMPLETE IN ACCORDANCE WITH CONTRACT DOCUMENTS AND READY FOR OWNER'S REVIEW. B) PROVIDE SUBMITTALS TO ARCHITECT/ENGINEER THAT ARE REQUIRED BY GOVERNING OR OTHER AUTHORITIES. C) SUBMIT FINAL APPLICATION FOR PAYMENT IDENTIFYING TOTAL ADJUSTED CONTRACT SUM, PREVIOUS PAYMENTS, AND SUM REMAINING DUE. S 0334 PROJECT NUMBER: 16-059 IS NOT OBLIGATED FOR COST INCURRED BY BIDDER IN PREPARING BID. OWNER IS NOT OBLIGATED TO ACCEPT LOWEST BID, OR ANY BID. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 SPECIFICATIONS SHEET TITLE ARCHITECTURAL SPECIFICATIONS SHEET NUMBER AS1.0 F. ARTICLE 33 - PROJECT RECORD DOCUMENTS A) MAINTAIN ON SITE, ONE SET OF THE FOLLOWING RECORD DOCUMENTS; RECORD ACTUAL REVISIONS TO THE WORK: 1. DRAWINGS. 2. SPECIFICATIONS. 3. ADDENDA. 4. CHANGE ORDERS AND OTHER MODIFICATIONS TO THE CONTRACT. 5. REVIEWED SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. 6. MANUFACTURER'S INSTRUCTION FOR ASSEMBLY, INSTALLATION, AND ADJUSTING. B) ENSURE ENTRIES ARE COMPLETE AND ACCURATE, ENABLING FUTURE REFERENCE BY OWNER. C) STORE RECORD DOCUMENTS SEPARATE FROM DOCUMENTS USED FOR CONSTRUCTION. D) RECORD INFORMATION CONCURRENT WITH CONSTRUCTION PROGRESS. E) SPECIFICATIONS: LEGIBLY MARK AND RECORD AT EACH PRODUCT DESCRIPTION OF ACTUAL PRODUCTS INSTALLED, INCLUDING THE FOLLOWING: 1. MANUFACTURER'S NAME AND PRODUCT MODEL AND NUMBER. 2. PRODUCT SUBSTITUTIONS OR ALTERNATES UTILIZED. 3. CHANGES MADE BY ADDENDA AND MODIFICATIONS. F) RECORD DOCUMENTS AND SHOP DRAWINGS: LEGIBLY MARK EACH ITEM TO RECORD ACTUAL CONSTRUCTION INCLUDING: 1. MEASURED HORIZONTAL AND VERTICAL LOCATIONS OF UNDERGROUND UTILITIES AND APPURTENANCES, REFERENCED TO PERMANENT SURFACE IMPROVEMENTS. 2. MEASURED LOCATIONS OF INTERNAL UTILITIES AND APPURTENANCES CONCEALED IN CONSTRUCTION, REFERENCED TO VISIBLE AND ACCESSIBLE FEATURES OF THE WORK. 3. FIELD CHANGES OF DIMENSION AND DETAIL. 4. DETAILS NOT ON ORIGINAL CONTRACT DRAWINGS. G) REMOVE ARCHITECT/ENGINEER TITLE BLOCK AND SEAL FROM ALL DOCUMENTS. H) FOLLOW CLOSE OUT PROCEDURE FROM PRE-CONSTRUCTION MEETING. G. H. ARTICLE 34 - OPERATION AND MAINTENANCE DATA A) FOR EACH PIECE OF OPERATING EQUIPMENT FURNISHED UNDER THIS CONTRACT, SUBMIT TO THE OWNER CONSOLIDATED OPERATION AND MAINTENANCE DATA INCLUDING THE FOLLOWING. 1. PURCHASE, INSTALLATION, BALANCING, AND ADJUSTMENT RECORDS, AS APPLICABLE. 2. MANUFACTURER'S INSTRUCTIONS FOR OPERATION, MAINTENANCE, DIAGNOSTICS, AND ADJUSTMENT PROCEDURES, AS APPROPRIATE. 3. CONTACT INFORMATION FOR SERVICE. 4. WARRANTY. B) WAIVER OF THESE O&M DATA SUBMITTAL REQUIREMENTS ARE SUBJECT TO APPROVAL BY THE OWNER'S REPRESENTATIVE.. I. ARTICLE 35 - WARRANTIES A) EXECUTE AND ASSEMBLE TRANSFERABLE WARRANTY DOCUMENTS FROM SUBCONTRACTORS, SUPPLIERS, AND MANUFACTURERS. B) FOR ITEMS OF WORK DELAYED BEYOND DATE OF SUBSTANTIAL COMPLETION, PROVIDE UPDATED SUBMITTAL WITHIN FIFTEEN DAYS AFTER ACCEPTANCE, LISTING DATE OF ACCEPTANCE AS START OF WARRANTY PERIOD. C) SUBMIT PRIOR TO FINAL APPLICATION FOR PAYMENT. J. ARTICLE 36 - SPARE PARTS AND MAINTENANCE MATERIALS A) PROVIDE PRODUCTS, SPARE PARTS, MAINTENANCE AND EXTRA MATERIALS IN QUANTITIES SPECIFIED IN INDIVIDUAL SPECIFICATION SECTIONS. B) DELIVER TO PROJECT SITE AND PLACE IN LOCATION AS DIRECTED; OBTAIN RECEIPT PRIOR TO FINAL PAYMENT. GENERAL SPECIFICATIONS K. DIVISION 01 - GENERAL REQUIREMENTS 013300 - SUBMITTAL PROCEDURES 1. GENERAL A. SUMMARY: SECTION INCLUDES 1) SUBMITTAL FORM REQUIREMENTS 2) SUBMITTAL SCHEDULE 3) CONTRACTOR RESPONSIBILITIES 4) REQUIREMENTS FOR EACH TYPE OF SUBMITTAL B. SUBMITTAL FORM REQUIREMENTS: PROVIDE THE FOLLOWING, AS APPLICABLE ON EACH SUBMITTAL: 1) PRESENT AND PREVIOUS SUBMITTAL DATES. 2) THE PROJECT TITLE AND NUMBER. 3) CONTRACTOR'S SUBMITTAL NUMBER. 4) SUBCONTRACT IDENTIFICATION. 5) THE NAMES OF: A) CONTRACTOR. B) SUPPLIER. C) MANUFACTURER. 6) IDENTIFICATION OF REVISIONS ON RESUBMITTALS. 7) FOR EACH PRODUCT, REFERENCE CORRESPONDING SPECIFICATION AND PARAGRAPH NUMBER. 8) A 6 X 4 INCH BLANK SPACE FOR STAMPS. C. DELIVER SUBMITTALS TO THE OWNER'S REPRESENTATIVE. INCLUDE NAME OF CONTACT PERSON IDENTIFIED AT THE TIME OF AGREEMENT. D. SUBMITTALS IN GRAPHIC FORM SHALL BE CLEAR READABLE COPIES WITH CONTRACTOR'S ORIGINAL STAMP. E. SUBMITTAL SCHEDULE 1) MAKE SUBMITTALS AS REQUIRED TO CAUSE NO DELAY IN THE WORK. 2) REQUIRE EACH SUBCONTRACTOR TO MAKE SUBMITTALS WITHIN 60 DAYS OF THE SUBCONTRACT DATE, UNLESS SPECIFIED OR APPROVED OTHERWISE, OR REQUIRED TO MEET THE WORK SCHEDULE. 3) SCHEDULE SUBMITTALS TO ALLOW SUFFICIENT TIME FOR POSSIBLE REVISION AND RESUBMITTAL OF THE REJECTED SUBMITTALS, WITHOUT AFFECTING THE CONSTRUCTION SCHEDULE. 4) MAKE THE FOLLOWING SUBMITTALS PRIOR TO STARTING CONSTRUCTION : A) CERTIFICATES OF INSURANCE. CONTAINERS OR PACKAGING, STORED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, UNTIL READY FOR INSTALLATION. 3) PRODUCTS INDICATED OR SCHEDULED AS VENDOR-FURNISHED WILL BE PAID FOR BY THE OWNER AND DELIVERED TO THE SITE. COORDINATE WITH THE OWNER. 4) PRODUCTS AND MATERIALS DAMAGED AFTER ACCEPTANCE OF DELIVERY SHALL BE REPLACED WITH NEW LIKE PRODUCTS, AT NO ADDITIONAL COST TO THE OWNER. B. GENERAL INSTALLATION REQUIREMENTS 1) ENVIRONMENTAL REQUIREMENTS: MAINTAIN TEMPERATURE RANGES, HUMIDITY, AND PROTECTION PROVISIONS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2) EXAMINATION A) PRIOR TO STARTING WORK, INSPECT INSTALLED WORK OF OTHER TRADES AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT WHERE WORK MAY PROPERLY COMMENCE. B) REQUIRE CORRECTION OF CONDITIONS DETRIMENTAL TO PROPER AND TIMELY COMPLETION OF THE WORK. C) BEGINNING WORK CONSTITUTES ACCEPTANCE OF SITE CONDITIONS AND RESPONSIBILITY FOR DEFECTIVE INSTALLATION CAUSED BY PRIOR OBSERVABLE CONDITIONS. 3) UNLESS INDICATED OR SPECIFIED OTHERWISE, INSTALL EACH PRODUCT IN ACCORDANCE WITH THE PRODUCT MANUFACTURER'S INSTRUCTIONS. 4) MAINTAIN ONE SET OF COMPLETE INSTRUCTIONS AT THE JOB SITE DURING INSTALLATION AND UNTIL COMPLETION. C. PRODUCT OPTIONS 1) PRODUCT SPECIFIED BY REFERENCE STANDARDS OR BY DESCRIPTION ONLY: PROVIDE PRODUCT MEETING THOSE STANDARDS. 2) PRODUCT SPECIFIED BY NAMING ONE OR MORE MANUFACTURERS WITH AN "OR APPROVED" PROVISION: USE SPECIFIED PRODUCT OR SUBMIT A REQUEST FOR SUBSTITUTION IN ACCORDANCE WITH THE SPECIFIED SUBSTITUTION REQUIREMENTS. WHEN APPROVED A SUBSTITUTE PRODUCT MAY BE USED. 3) PRODUCT SPECIFIED BY NAMING ONE OR MORE MANUFACTURERS, WITHOUT A PROVISIONS FOR SUBSTITUTION: NO SUBSTITUTION WILL BE ALLOWED, EXCEPT AS SPECIFIED UNDER THE ARTICLE ON SUBSTITUTIONS. D. SUBSTITUTIONS: IN ACCORDANCE WITH THE GENERAL AND SUPPLEMENTARY CONDITIONS, AND AS FOLLOWS. 1) FURNISH PRODUCTS SPECIFIED, EXCEPT WHERE "OR APPROVED" IS USED; SUBSTITUTE PRODUCTS MAY BE SUBMITTED TO ARCHITECT FOR APPROVAL. 2) SUBSTITUTIONS WILL BE CONSIDERED ONLY FOR THE FOLLOWING REASONS: A) A PRODUCT BECOMES UNAVAILABLE DUE TO NO FAULT OF THE CONTRACTOR. B) A SUBSTITUTE PRODUCT WILL BE IN OWNER'S BEST INTEREST BY PROVIDING A COST SAVINGS, PRODUCT QUALITY OR UTILITY ADVANTAGE, OR SCHEDULE BENEFIT. 3) DOCUMENT EACH SUBSTITUTION REQUEST WITH COMPLETE DATA SUBSTANTIATING COMPLIANCE OF PROPOSED SUBSTITUTION WITH CONTRACT DOCUMENTS. 4) A SUBSTITUTION REQUEST CONSTITUTES A REPRESENTATION THAT CONTRACTOR: A) HAS INVESTIGATED PROPOSED PRODUCT AND HAS DETERMINED THAT IT MEETS OR EXCEEDS PERFORMANCE OF THE SPECIFIED PRODUCT, IN ALL RESPECTS. B) SHALL PROVIDE THE SAME WARRANTY FOR SUBSTITUTION AS FOR SPECIFIED PRODUCT. C) WILL COORDINATE INSTALLATION AND MAKE OTHER CHANGES WHICH MAY BE REQUIRED FOR WORK TO BE COMPLETE IN ALL RESPECTS. D) WAIVES CLAIMS FOR ADDITIONAL COSTS THAT MAY SUBSEQUENTLY BECOME APPARENT. E) AGREES TO PAY ALL COSTS OF REDESIGN RELATED TO THE SUBSTITUTION. 5) UNLESS PREVIOUSLY APPROVED, SUBSTITUTIONS IMPLIED ON SHOP DRAWINGS WILL NOT BE ACCEPTED. 6) THE ARCHITECT WILL DETERMINE ACCEPTABILITY OF PROPOSED SUBSTITUTION, COORDINATE WITH THE OWNER, AND WILL NOTIFY CONTRACTOR OF ACCEPTANCE OR REJECTION WITHIN A REASONABLE TIME. C) 018113 - SUSTAINABLE DESIGN REQUIREMENTS B. C. D. E. TEMPORARY HEATING: PROVIDE TEMPORARY HEAT TO PROTECT WORK AND MATERIALS AGAINST INJURY FROM DAMPNESS AND COLD AND TO DRY OUT BUILDING. FUEL, EQUIPMENT, AND METHOD OF HEATING SATISFACTORY TO ARCHITECT. MINIMUM TEMPERATURE FOR WORK 50 DEGREES FAHRENHEIT. TEMPORARY UTILITIES: ARRANGE FOR AND FURNISH WATER, GAS AND ELECTRICITY TO DATE OF OCCUPANCY BY OWNER. FURNISH ELECTRICITY FOR LIGHT AND POWER DURING CONSTRUCTION PERIOD INCLUDING LAMPS. OTHER CONTRACTORS USING TEMPORARY SERVICES SHALL PAY FOR ALL DAMAGES TO LIFE, LIMB OR PROPERTY WHICH RESULT FROM THEIR USE OF TEMPORARY SERVICES. SANITARY CONVENIENCES: PROVIDE SANITARY CONVENIENCES REQUIRED FOR WORKMEN AND MAINTAIN SAME IN SANITARY CONDITION. TEMPORARY TELEPHONE AND FAX SERVICE: PROVIDE JOB TELEPHONE, LISTED WITH TELEPHONE COMPANY UNDER THE NAME OF THE GENERAL CONTRACTOR. TELEPHONE, PORTABLE TELEPHONE AND FAX MACHINE TO BE INSTALLED IMMEDIATELY UPON START OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF CONSTRUCTION. POTBELLY SANDWICH WORKS WILL ARRANGE FOR INSTALLATION OF PERMANENT SERVICE AT THE TIME OF OCCUPATION OF BUILDING. PHONE TO HAVE OUTSIDE BELL OR BUZZER. PROVIDE AND MAINTAIN ALL NECESSARY TEMPORARY STAIRS, LADDERS, RAMPS, PLATFORMS, HOISTS, ETC., AS REQUIRED FOR PROPER EXECUTION OF THE WORK, ALL OF WHICH SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL CODES. 016000 - PRODUCT REQUIREMENTS A. DELIVERY, STORAGE, AND HANDLING: 1) TRANSPORT AND HANDLE PRODUCTS BY METHODS TO AVOID PRODUCT DAMAGE. 2) MANUFACTURED PRODUCTS SHALL REMAIN IN MANUFACTURER'S WATER EFFICIENCY A) WE CREDIT 2 - WATER USE REDUCTION: WATER USING APPLIANCES AND FIXTURES SHALL EXCEED BASELINE LEVELS BY A MINIMUM ENERGY AND ATMOSPHERE A) EA PREREQUISITE 1 - FUNDAMENTAL COMMISSIONING OF BUILDING ENERGY SYSTEMS: COORDINATE WITH OWNER FOR STARTUP AND COMMISSIONING OF HVAC B) EA PREREQUISITE 3 - FUNDAMENTAL REFRIGERANT MANAGEMENT: VERIFY REFRIGERANT TYPE. 4) MATERIALS AND RESOURCES A) MR CREDIT 2 - CONSTRUCTION WASTE MANAGEMENT: SUBMIT AS REQUIRED TO DOCUMENT SORTING, QUANTITIES, AND DISPOSITION AND DIVERSION OF CONSTRUCTION WASTE INCLUDING (1) CONCRETE (2) WOOD (3) GYPSUM (4) CARDBOARD (5) PLASTIC (6) MIXED WASTE B) MR CREDIT 4 - RECYCLED CONTENT: MINIMUM 10 PERCENT INCORPORATED RECYCLED CONTENT, BASED ON COST AND DETERMINED BY SUM OF POST-CONSUMER PLUS 1. MR CREDIT 5 - REGIONAL MATERIALS: MINIMUM 20 PERCENT OF MATERIALS AND PRODUCTS, BASED ON COST OF COMPONENTS AND CONTENT EXTRACTED, HARVESTED, RECOVERED, OR MANUFACTURED WITHIN 500 MILES OF THE PROJECT SITE. D) MR CREDIT 7 - CERTIFIED WOOD: MINIMUM 50 PERCENT, BASED ON RELATIVE COST OF INCORPORATED CONTENT, WOOD AND WOOD PRODUCTS CERTIFIED BY THE FOREST STEWARDSHIP COUNCIL 5) INDOOR ENVIRONMENTAL QUALITY. A) IEQ CREDIT 3.1; 3.2 - CONSTRUCTION IAQ MANAGEMENT PLAN: DEVELOP AND IMPLEMENT AN IAQ MANAGEMENT PLAN FOR CONSTRUCTION AND PRE-OCCUPANCY PHASES OF THE BUILDING. (1) MEET OR EXCEED RECOMMENDED CONTROL MEASURES OF SMACNA IAQ GUIDELINES FOR OCCUPIED BUILDINGS UNDER CONSTRUCTION, 2ND EDITION 2007. (2) PROTECT ONSITE AND INSTALLED ABSORPTIVE MATERIALS FROM MOISTURE. (3) FOR HVAC EMPLOYED DURING CONSTRUCTION, USE MINIMUM MERV 8 FILTRATION. REPLACE FILTRATION MEDIA IMMEDIATELY PRIOR TO PROJECT TURNOVER. (4) AFTER CONSTRUCTION ENDS AND PRIOR TO OCCUPANCY, PERFORM PROJECT AREA FLUSH-OUT BY SUPPLYING A TOTAL AIR VOLUME OF 14,000 CF OF OUTDOOR AIR PER SF OF PROJECT FLOOR AREA. B) IEQ CREDIT 4 - LOW EMITTING MATERIALS. (1) CREDIT 4.1 - ADHESIVES AND SEALANTS: LIMIT VOC CONTENT OF EACH RAW MATERIAL IN ACCORDANCE WITH SCAQMD RULE 1168, AMENDED JANUARY 7, 2005; LIMIT AEROSOL ADHESIVES IN ACCORDANCE WITH GREEN SEAL GS-36, EFFECTIVE OCTOBER 19, 2000. (2) CREDIT 4.2 - PAINTS AND COATINGS: LIMIT VOC CONTENT OF EACH RAW MATERIAL IN ACCORDANCE WITH GREEN SEAL GS-11, EFFECTIVE MAY 20, 1993; LIMIT ANTI-CORROSIVE AND PRODUCTS - NOT USED 3. EXECUTION A. GENERAL 1) CORRECTION OF WORK NOT CONFORMING WITH SPECIFIED SUSTAINABILITY REQUIREMENTS SHALL BE PERFORMED AT CONTRACTOR'S EXPENSE. 2) SUSTAINABILITY INTRODUCTION MEETING: ADDRESS AS A SEPARATE AGENDA ITEM AN ORIENTATION SESSION TO FAMILIARIZE CONSTRUCTION FORCES WITH SUSTAINABILITY INTENT. B. SUSTAINABILITY OBJECTIVES 1) INTENT A) PERFORM WORK TO QUALIFY FOR THE FOLLOWING LEED-NC EQUIVALENT PREREQUISITES AND CREDITS. UNLESS OTHERWISE INDICATED, WHERE CONTRACTOR- AND OWNER-FURNISHED MATERIALS AND EQUIPMENT ARE CONTRIBUTORY, DOCUMENT TO INDICATE AGGREGATE CONTRIBUTIONS TO ACHIEVE CREDITS AT THE LEVELS INDICATED. COMPLY WITH REFERENCED DOCUMENTS FOR SPECIFIC REQUIREMENTS. B) WHERE TARGET PERCENTAGES ARE INDICATED, MEET OR EXCEED THOSE REQUIREMENTS TO THE GREATEST REASONABLE EXTENT. 3. (3) (4) (5) FLOOR COATINGS, STAINS, PRIMERS AND SHELLACS IN ACCORDANCE WITH SCAQMD RULE 1113, EFFECTIVE JANUARY 1, 2004. CREDIT 4.3 - FLOORING SYSTEMS: (a) RESILIENT FLOORING AND BASE; CERAMIC TILE FLOORING: CERTIFIED AS COMPLIANT WITH CALIFORNIA DEPARTMENT OF HEALTH SERVICES (FLOOR SCORE). (b) TILE SETTING ADHESIVES: LIMIT VOC CONTENT OF EACH RAW MATERIAL IN ACCORDANCE WITH SCAQMD RULE 1168, AMENDED JANUARY 7, 2005. CREDIT 4.4 - COMPOSITE WOOD AND AGRIFIBER PRODUCTS: VERIFY FREEDOM FROM ADDED UREA_FORMALDEHYDE. CREDIT 4.6 - CEILING AND WALL SYSTEMS: VERIFY COMPLIANCE WITH CALIFORNIA DHS STANDARD PRACTICE FOR TESTING OF VOLATILE ORGANIC EMISSIONS, INCLUDING 2004 ADDENDA. DIVISION 02 - EXISTING CONDITIONS A. B. C. D. E. F. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER AS REQUIRED TO ACCOMMODATE THE WORK. WHERE DEMOLITION EXCEEDS THAT INDICATED, VERIFY SUCH DEMOLITION WITH THE ARCHITECT AND THE LANDLORD PRIOR TO PROCEEDING. NOTIFY THE LANDLORD PRIOR TO CUTTING OR FASTENING INTO CONCRETE SLABS. X-RAY AS DIRECTED AND AS NECESSARY TO DETERMINE LOCATION OF TENDONS, REINFORCING, OR UTILITIES. NOTIFY THE OWNER PRIOR TO COMMENCING DEMOLITION WORK, COORDINATE WITH OWNER FOR REMOVAL OF ITEMS TO BE CLAIMED. EXCEPT WHERE NOTED OR SPECIFIED OTHERWISE, TAKE POSSESSION OF MATERIALS BEING DEMOLISHED, AND IMMEDIATELY REMOVE FROM SITE. DO NOT OVERLOAD EXISTING CONSTRUCTION TO REMAIN WITH DEMOLISHED MATERIALS. PROVIDE A SMOOTH, EVEN, AND INVISIBLE TRANSITION TO NEW CONSTRUCTION. WHEN FINISHED SURFACES ARE CUT SO THAT AN INVISIBLE TRANSITION WITH NEW WORK IS NOT POSSIBLE, TERMINATE EXISTING SURFACE ALONG THE NEAREST BREAK LINE, JOINT, OR CORNER. WHERE SLAB PENETRATIONS ARE INDICATED OR REQUIRED, X-RAY THE SLAB PRIOR TO CUTTING. NOTIFY THE ARCHITECT FOR RESOLUTION WHERE TENDONS, REINFORCING, OR EMBEDDED UTILITIES ARE DISCOVERED. REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED, AT NO ADDITIONAL COST TO THE OWNER. DIVISION 03 - CONCRETE 030133 - CAST-IN-PLACE CONCRETE 1. 2. GENERAL A. SECTION INCLUDES: 1) CONCRETE SLAB INFILL AND CURBS. 2) TRENCHING AND PIPE BEDDING. 3) CAST-IN-PLACE CONCRETE FOR INFILL OF TRENCHES. PRODUCTS A. PLYWOOD: APA MEDIUM DENSITY OR HIGH DENSITY OVERLAY, PLYFORM REINFORCING: AS INDICATED ON THE DRAWINGS. C. CONCRETE MATERIALS: 1) CEMENT: ASTM C150, NORMAL - TYPE 1 PORTLAND CEMENT. 2) NORMAL WEIGHT FINE AND COARSE AGGREGATES: ASTM C33. 3) WATER: CLEAN AND NOT DETRIMENTAL TO CONCRETE. 4) ADMIXTURES B. 054000 - COLD FORMED METAL FRAMING 1. EXECUTION A. TRENCHING 1) COORDINATE WITH DIVISION 02, PLUMBING, AND MECHANICALWORK AS APPROPRIATE A) MAKE TRENCHES WITH SUFFICIENT WIDTH TO PERMIT INSTALLATION. B) WHERE WATERPROOF MEMBRANE IS INDICATED OR REQUIRED, REPAIR DAMAGE TO EXISTING MEMBRANE AS NECESSARY TO MAINTAIN BARRIER BETWEEN NEW CONSTRUCTION AND OCCUPIED SPACE BELOW. B. PLACEMENT 1) MIX CONCRETE IN ACCORDANCE WITH ASTM C94; MINIMUM 3000 PSI, PLACEMENT AND FINISHING: A) USE BONDING AGENT AT INTERFACE WITH EXISTING SLAB EDGE B) PLACE REINFORCING AND CONCRETE IN ACCORDANCE WITH ACI 301. C) FINISH CONCRETE SLABS LEVEL AS INDICATED ON THE DRAWINGS. D) FULL TROWEL FINISH INTERIOR FLOOR SLAB SURFACES TO MATCH ADJACENT WORK. C. CURING: MOISTURE CURE ALL CONCRETE FOR A MINIMUM OF 7 DAYS. C) GENERAL A. SUMMARY 1) WHERE PRACTICAL, THIS PROJECT WILL VOLUNTARILY COMPLY WITH USGBC REQUIREMENTS FOR SUSTAINABLE DESIGN AND CONSTRUCTION FOR NEW CONSTRUCTION AS SPECIFIED. 2) EXCEPT AS OTHERWISE INDICATED, WHERE SUBMITTALS ARE REQUIRED TO DOCUMENT COMPLIANCE WITH DESIGN INTENT, SUBMITTALS FOR VERIFICATION OF ITEMS SUCH AS SUSTAINABLE SITES REQUIREMENTS, WATER EFFICIENCY, ENERGY PERFORMANCE, THERMAL COMFORT, AND FACILITY OPERATION ARE OUTSIDE THE SCOPE OF THIS CONTRACT. B. REFERENCES 1) LEED REFERENCE GUIDE FOR BUILDING DESIGN AND CONSTRUCTION, 2009 EDITION. 2) LEED REFERENCE GUIDE FOR BUILDING DESIGN AND CONSTRUCTION RETAIL SUPPLEMENT, 2009 EDITION. C. REQUIREMENTS 1) MAKE SUBMITTALS AS SPECIFIED, AS REQUESTED, AND NECESSARY TO SUPPORT SPECIFIC SUSTAINABILITY REQUIREMENTS. 2) TRACK MATERIALS AND PROCEDURES AS NECESSARY TO VERIFY ACHIEVEMENT OF OBJECTIVES. 3) COORDINATE THE WORK TO INTEGRATE THE WORK AMONG REQUIREMENTS FOR AIR QUALITY MANAGEMENT, CONSTRUCTION WASTE MANAGEMENT, AND COMMISSIONING. 2. WATER REDUCER NORMAL: ASTM C494, TYPE A. ACCELERATOR: ASTM C494, TYPE C OR E, NON-CORROSIVE, NON-CHLORIDE. D. ACCESSORIES: 1) BONDING AGENT: 2-COMPONENT MOISTURE INSENSITIVE, 100 PERCENT SOLIDS EPOXY ADHESIVE WITH SHEAR BOND TO CONCRETE STRENGTH >1400 PSI. 2) CURING MATERIALS: WATERPROOF SHEET: ASTM C171; MINIMUM 4 MIL POLYETHYLENE SHEET OR REINFORCED WATERPROOF KRAFT PAPER. 3) WATERPROOF MEMBRANE: MATCH EXISTING, UNLESS APPROVED OTHERWISE.. A) B) 3) 024119 - SELECTIVE DEMOLITION 015000 - TEMPORARY FACILITIES A. 2) 2) 035416 - HYDRAULIC CEMENT UNDERLAYMENT AND TOPPING 1. GENERAL A. SECTION INCLUDES: LEVELING OF EXISTING CAST-IN-PLACE CONCRETE SLABS. 2. PRODUCTS A. SELF LEVELING TOPPING SYSTEM: POURABLE, CEMENT BASED MATERIAL, TRAFFIC BEARING TYPE; MINIMUM 28 DAY COMPRESSIVE STRENGTH 6,000 PSI; MINIMUM BOND STRENGTH 200 PSI. 1) BASIS OF DESIGN: MAPEI AMERICAS "ULTRATOP"; GRAY COLOR. 2) ACCEPTABLE OPTIONS (SUBJECT TO COMPLIANCE WITH CONTRACT DOCUMENT REQUIREMENTS AND ARCHITECT'S APPROVAL OF CONFORMANCE TO DESIGN INTENT.): A) ARDEX INC. "SD-T" SELF-LEVELING SELF-DRYING CONCRETE TOPPING. B) PROSPEC "LEVEL SET WEAR TOPPING." B. SELF LEVELING UNDERLAYMENT SYSTEM: POURABLE, CEMENT BASED MATERIAL, MINIMUM 28 DAY COMPRESSIVE STRENGTH 3,000 PSI; MINIMUM BOND STRENGTH 200 PSI. 1) BASIS OF DESIGN: MAPEI AMERICAS "ULTRAPLAN 1 PLUS". 2) ACCEPTABLE OPTIONS (SUBJECT TO COMPLIANCE WITH CONTRACT DOCUMENT REQUIREMENTS AND ARCHITECT'S APPROVAL OF CONFORMANCE TO DESIGN INTENT.): A) ARDEX INC. "K-15" SELF-LEVELING UNDERLAYMENT CONCRETE. B) KOESTER AMERICAN CORPORATION "VAP-1 LEVEL PRO." C) SUPERCAP (HASLET TX; 866_704_2247) "SUPERCAP SELF-LEVELING UNDERLAYMENT." D) PROSPEC "LEVEL SET 300." E) LATICRETE INTERNATIONAL, INC. "LATICRETE 86 LATILEVEL THIN POUR UNDERLAYMENT." C. REPAIR MORTAR: MAPEI AMERICAS "PLANITOP X," OR APPROVED. D. ACCESSORIES: FURNISH PRIMERS, PATCHING COMPOUNDS, AND SAND FILLERS AS NECESSARY FOR TROWELABLE APPLICATIONS AND AS RECOMMENDED BY THE UNDERLAYMENT MANUFACTURER FOR THE CONDITIONS OF THE PROJECT. 3. EXECUTION A. GENERAL: 1) SURFACES SCHEDULED FOR SEALED CONCRETE: INSTALL CEMENTITIOUS TOPPING TO CONCRETE SLABS AS INDICATED ON THE DRAWINGS, AND AS NECESSARY TO LEVEL SLABS OR BRING SUBSTRATES TO PROPER ELEVATION. 2) SURFACES TO RECEIVE SUBSEQUENT ADHERED FINISHES: WITH THE EXCEPTION OF AREAS WHERE LEVELING CAN BE ACCOMPLISHED BY USE OF LATEX UNDERLAYMENT, AS SPECIFIED IN SECTION 096519, INSTALL CEMENTITIOUS UNDERLAYMENT TO CONCRETE SLABS AS INDICATED ON THE DRAWINGS OR AS DETERMINED BY THE OWNER'S REPRESENTATIVE DURING FIELD VISIT, AND AS NECESSARY TO LEVEL SLABS OR BRING SUBSTRATES TO PROPER ELEVATION. 3) PROVIDE ADDITIONAL TOPPING AT LOCATIONS AS DIRECTED AND AS NECESSARY FOR MOCK-UPS OF STAIN AND SEALER SYSTEMS. B. PREPARATION 1) SURVEY FLOOR AS NECESSARY TO SET SCREEDS AND REFERENCE POINTS. IDENTIFY CONSTRUCTION JOINTS, AND CONTROL JOINTS. PREPARE FOR UNDERLAYMENT AT ALL LOCATIONS WHERE FLOOR DOES NOT MEET SPECIFIED TOLERANCE REQUIREMENTS. 2) ENSURE THAT SUBFLOOR IS CLEAN, DRY, HARD, SOUND, AND FREE OF OILS, OR OTHER SUBSTANCE WHICH WOULD AFFECT PROPER BONDING AND CURING. VERIFY THAT ALL AREAS TO BE LEVELED ARE AT OR BELOW FINAL DESIGN ELEVATION. 3) COORDINATE WITH PLUMBING WORK AND SECTION 093000 FOR ESTABLISHMENT OF LEVELS AND PITCHES TO DRAIN. C. APPLICATION 1) INSTALL TROWELABLE UNDERLAYMENT AT LOCATIONS WHERE SLOPES ARE INDICATED AND AT OTHER LOCATIONS AS APPROPRIATE TO INSTALLATION CONDITIONS; INSTALL SELF LEVELING UNDERLAYMENT AT OTHER LOCATIONS AS NECESSARY TO CORRECT SLAB FLATNESS AND LEVELNESS. 2) WHERE SUBSEQUENT FINISHING OF THE MATERIAL IS REQUIRED, FLOAT TO LEVEL SURFACE. 3) APPLY PRIMER TO ALL AREAS TO RECEIVE UNDERLAYMENT; REPEAT APPLICATION IF NECESSARY TO ACHIEVE PROPER BUILD. 4) MIX MATERIALS AND POUR OR PUMP AND SQUEEGEE INTO PLACE TO ACHIEVE APPROPRIATE THICKNESS. FINISH TO A SMOOTH LEVEL SURFACE WITHIN TOLERANCES SPECIFIED FOR CONCRETE FLOORS. CURE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. D. TOLERANCES: 1) 2) RAMPS AT TRANSITIONS AND SLOPES TO DRAIN: MAXIMUM SLOPE 1/4" PER FOOT. DIVISION 04 - MASONRY (NOT USED) DIVISION 05 - METAL GENERAL A. SECTION INCLUDES: 1) EXTERIOR LIGHTGAGE (AXIAL AND TRANSVERSE) LOAD BEARING METAL FRAMING, WITH ANCHORAGE AND BRACING. 2) STRUCTURAL DESIGN OF SYSTEMS. B. SYSTEM DESCRIPTION 1) STRUCTURAL DESIGN: A) SIZE AND ARRANGE MEMBERS TO SUPPORT DEAD LOADS, AND TO RESIST LIVE LOADS INDICATED ON THE STRUCTURAL DRAWINGS, AND INCLUDING WIND LOADS IN ACCORDANCE WITH THE LOCAL JURISDICTIONAL REQUIREMENTS. B) DESIGN SYSTEM TO RESIST 100 PERCENT OF THE DESIGN LOAD WITH A MAXIMUM DEFLECTION OF L/360. C) DESIGN SYSTEM TO ACCOMMODATE BUILDING DEFLECTION, DYNAMIC BUILDING MOVEMENT, AND TEMPERATURE VARIATIONS WITHOUT DAMAGE TO SYSTEM COMPONENTS. DESIGN SYSTEMS TO ACCOMMODATE A FLOOR DEFLECTION OF 3/4 INCH. 2) CONFIGURATION: A) PROVIDE FRAMING OF DEPTH INDICATED ON THE DRAWINGS. B) WHERE STUD GAGE IS INDICATED ON THE DRAWINGS, PROVIDE STUDS OF INDICATED OR HEAVIER GAGE. C) WHERE STUD SPACING IS INDICATED ON THE DRAWINGS, PROVIDE ADDITIONAL STUDS OR CLOSER SPACING AS NECESSARY TO MEET DESIGN REQUIREMENTS. D) IN ADDITION TO COLD FORMED METAL FRAMING INDICATED ON THE DRAWINGS, PROVIDE ADDITIONAL MEMBERS LOCATED AS NECESSARY TO ANCHOR SUPERIMPOSED LOADS. C. SUBMITTALS 1) SHOP DRAWINGS: A) INDICATE TYPICAL AND SPECIAL DETAILS, INCLUDING FRAMING DETAILS, ANCHORAGE SYSTEMS, FASTENING SYSTEMS, LOADS, AND ACCESSORIES OR ITEMS REQUIRED OF OTHER WORK FOR COMPLETE INSTALLATION. B) INCLUDE DESIGN ENGINEER'S SEAL, IF REQUIRED. D. QUALITY ASSURANCE 1) USE ONLY WELDERS CERTIFIED BY AWS, OR AS OTHERWISE REQUIRED BY THE AHJ. . 2) WELDING: AWS D1.3. 3) STRUCTURAL DESIGN: EXCEPT WHERE SIZES, SPACING, CONNECTIONS, AND SPECIAL FRAMING CONDITIONS ARE SPECIFICALLY INDICATED ON THE STRUCTURAL DRAWINGS, FRAMING SYSTEMS SHALL BE DESIGNED BY A STRUCTURAL ENGINEER LICENSED TO PRACTICE IN STATE WHERE PROJECT IS LOCATED. 2. PRODUCTS A. COMPONENTS 1) COLD FORMED LIGHT-GAGE STEEL FRAMING: ASTM A653; MINIMUM G60 GALVANIZED COATING. 2) FABRICATE FROM STEEL SHEET; QUALITY SQ, GRADE 50; MINIMUM 16 GAGE. 3) FINISH: G60 ZINC COATED FINISH IN ACCORDANCE WITH ASTM A653. 4) STUDS: C SHAPED SECTIONS; MINIMUM 1-5/8 INCH WIDE FLANGES WITH RETURN LIP. B. ACCESSORIES: 1) SCREWS: ASTM C954; SELF DRILLING, SELF TAPPING; PAN HEAD; GALVANIZED OR FLUOROPOLYMER COATED STEEL. 2) SILL GASKET: CLOSED CELL POLYETHYLENE FOAM, GLASS FIBER STRIPS, OR APPROVED; CONTINUOUS ROLLS; WIDTH OF SILL PLATE. 3. EXECUTION A. INSTALL LIGHTGAGE STRUCTURAL FRAMING IN ACCORDANCE WITH ASTM C1007, UNLESS INDICATED OR SPECIFIED OTHERWISE. B. PLACE SILL GASKET UNDER RUNNERS FOR EXTERIOR PARTITIONS. PUNCTURE GASKET CLEAN AND FIT TIGHT TO PROTRUDING FOUNDATION ANCHOR BOLTS. C. UNLESS OTHERWISE INDICATED, SCREW OR WELD EACH JOINT. WELD IN ACCORDANCE WITH AWS D1.3. D. SAW OR SHEAR CUT METAL FRAMING MEMBERS . NO TORCH CUTTING PERMITTED. E. ERECT STUDS IN ONE PIECE FULL LENGTH. SPLICING AND WIRE TYING OF FRAMING COMPONENTS SHALL NOT BE USED. F. CONSTRUCT CORNERS WITH A MINIMUM OF 3 STUDS PER CORNER. G. TOLERANCES: 1) PLUMB: 1/8 INCH IN 10 FEET. 2) LOCATION: WITHIN 1/4 INCH OF THE REQUIRED LOCATION. 3) LEVEL: 1/8 INCH IN 10 FEET. H. TOUCH-UP FIELD WELDS AND SCRATCHED OR DAMAGED GALVANIZING IN ACCORDANCE WITH REQUIREMENTS OF ASTM A780. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. C Wells H I S t ., T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 055000 - METAL FABRICATIONS 1. GENERAL A. SECTION INCLUDES: 1) STEEL FABRICATIONS INDICATED ON THE ARCHITECTURAL DRAWINGS AND NOT SPECIFIED IN OTHER SECTIONS. 2) MISCELLANEOUS ORNAMENTAL METAL FABRICATIONS, INCLUDING DECORATIVE EXPOSED STRUCTURAL ELEMENTS. B. SHOP DRAWINGS: INDICATE PROFILES, SIZES, CONNECTION ATTACHMENTS, REINFORCING, SIZES AND TYPES OF FASTENERS, FINISHES, AND ACCESSORIES. 2. PRODUCTS: A. STEEL 1) STEEL PLATE, BARS, SHAPES: ASTM A36. 2) TUBES: ASTM A500 OR A501. 3) PIPE: ASTM A53, SEAMLESS, TYPE S, PLAIN END; SCHEDULE 40 UNLESS INDICATED OTHERWISE. B. STAINLESS STEEL: ASTM A167; TYPE 304. C. FASTENERS: 1) AS APPROPRIATE TO THE APPLICATION; COMPATIBLE WITH MATERIALS BEING FASTENED; GALVANIZED WHERE INDICATED FOR USE IN EXTERIOR OR DAMP LOCATIONS.. 2) BOLTS AND NUTS: ASTM A307 D. FABRICATION: 1) AS INDICATED, AND IN ACCORDANCE WITH APPROVED SHOP DRAWINGS. 2) FOR ITEMS EXPOSED TO VIEW OR SUBJECT TO CONTACT, GRIND WELDS SMOOTH AND LEVEL WITH ADJACENT SURFACES; REMOVE ALL BURRS FROM CUT EDGES. 3) STAINLESS STEEL WATER HEATER PAN: FABRICATE FROM MINIMUM 24 GAGE STAINLESS STEEL; SOLDERED CORNERS; HEMMED EDGES. 4) SHOP FINISHES: A) GALVANIZED: (1) CONCEALED: NO FURTHER FINISH (2) EXPOSED TO VIEW: AS INDICATED. B) UNGALVANIZED STEEL: FACTORY PRIME PAINTED AFTER FABRICATION. C) OTHER METAL FABRICATIONS: AS DIRECTED. S 0334 PROJECT NUMBER: 16-059 A) EXECUTE FINAL CLEANING PRIOR TO FINAL PROJECT ASSESSMENT. B) CLEAN INTERIOR AND EXTERIOR GLASS, SURFACES EXPOSED TO VIEW; REMOVE TEMPORARY LABELS, STAINS AND FOREIGN SUBSTANCES, POLISH TRANSPARENT ANDGLOSSY SURFACES. C) CLEAN EQUIPMENT AND FIXTURES TO A SANITARY CONDITION WITH CLEANING MATERIALS APPROPRIATE TO THE SURFACE AND MATERIAL BEING CLEANED. D) REPLACE FILTERS OF OPERATING EQUIPMENT. E) CLEAN DEBRIS FROM ROOFS, GUTTERS, DOWNSPOUTS, AND DRAINAGE SYSTEMS. F) CLEAN SITE; SWEEP PAVED AREAS. G) REMOVE WASTE AND SURPLUS MATERIALS, RUBBISH, AND CONSTRUCTION FACILITIES FROM THE SITE. LIST OF SUBCONTRACTORS AND SUPPLIERS. CONSTRUCTION SCHEDULE. D) SUBMITTAL LOG. PRODUCTS LIST. GENERAL SUBMITTAL REQUIREMENTS 1) MAKE SUBMITTALS AS REQUESTED, AS REQUIRED BY INDIVIDUAL SPECIFICATION SECTIONS, AND AS OTHERWISE NECESSARY TO CONFIRM INTENT OR COMPLIANCE. SUBMITTALS FOR OWNER FURNISHED PRODUCTS ARE NOT REQUIRED. 2) REVIEW SUBMITTAL MATERIALS PRIOR TO SUBMITTAL. VERIFY SPECIFIED REQUIREMENTS FOR PRODUCTS, FIELD MEASUREMENTS, AND FIELD CONSTRUCTION REQUIREMENTS. 3) STAMP AND SIGN EACH SUBMITTAL AS CERTIFICATION THAT THE SUBMITTAL HAS BEEN REVIEWED BY THE CONTRACTOR. SUBMITTALS NOT STAMPED AND SIGNED BY THE CONTRACTOR WILL BE RETURNED. 4) NOTE IN WRITING, AT TIME OF SUBMITTAL, ALL DEVIATIONS IN THE SUBMITTALS FROM REQUIREMENTS OF THE CONTRACT DOCUMENTS. 5) MAKE COPIES OF ALL APPROVED SHOP DRAWINGS AND PRODUCT LITERATURE AVAILABLE FOR USE IN THE PROJECT. 6) REVIEW AND APPROVAL OF A SUBMITTAL SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE PROPER FITTING, FINISHING, QUANTITIES, AND ERECTION OF THE WORK IN STRICT ACCORDANCE WITH THE CONTRACT REQUIREMENTS. 7) REVIEW AND APPROVAL OF A SUBMITTAL SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY FOR PROVIDING WORK NOT INDICATED ON THE SUBMITTAL, BUT OTHERWISE REQUIRED FOR THE COMPLETION OF THE WORK. 8) DO NOT FABRICATE OR ERECT WORK PRIOR TO APPROVAL OF THE SUBMITTALS. 9) SHOULD DISCREPANCIES BECOME EVIDENT, IMMEDIATELY NOTIFY ARCHITECT FOR RESOLUTION BEFORE PROCEEDING WITH SHOP WORK. 10) INCLUSION OF SUBSTITUTION REQUESTS INTO SUBMITTALS WILL BE CONSIDERED CAUSE FOR REJECTION OF THE SUBMITTAL. 11) SUBMITTALS WILL BE REVIEWED FOR CONFORMANCE TO THE DESIGN CONCEPT, ONLY. REVIEW OF VENDOR DESIGNED ITEMS SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR COMPLIANCE WITH SPECIFIED PERFORMANCE REQUIREMENTS. CONSTRUCTION SCHEDULE 1) SHOW COMMENCEMENT AND COMPLETION DATES PROPOSED FOR EACH SUBDIVISION OF WORK. 2) COORDINATE WITH THE OWNER'S SCHEDULE, SHOWING ALL CONTRACT ACTIVITIES TO BE PERFORMED BY THE OWNER INCLUDING THEIR START, DURATION, COMPLETION, FLOAT AND CRITICAL PATH. SHOP DRAWINGS 1) SUBMIT SHOP DRAWINGS REQUIRED BY INDIVIDUAL SECTIONS OF THE SPECIFICATIONS, AND AS OTHERWISE REQUIRED FOR PROPER PERFORMANCE OF THE WORK. 2) ILLUSTRATE FULLY THE REQUIREMENTS OF THE SPECIFICATIONS AND THE CONTRACT DRAWINGS, AND ACCURATELY SHOW QUANTITIES, KINDS OF MATERIALS, METHODS OF ASSEMBLY, AND ALL DATA REQUIRED FOR FABRICATION, ERECTION, AND INSTALLATION. 3) SHOW THE RELATIONSHIP OF ADJOINING WORK, RELEVANT FIELD CONDITIONS AND DIMENSIONS; COORDINATE WITH AFFECTED SUBCONTRACTORS AND SUPPLIERS IF IN CONFLICT. 4) NUMBER OF COPIES: UNLESS OTHERWISE SPECIFIED, SUBMIT 2 LEGIBLE RIGHT-READING COPIES TO THE ARCHITECT, POTBELLY FOR REVIEW. 5) THE ARCHITECT, POTBELLY WILL RETURN ONE COPY TO CONTRACTOR WITH CORRECTIONS, NOTATIONS AND STAMP INDICATING ACTION TO BE TAKEN. PRODUCT DATA 1) MARK EACH COPY TO IDENTIFY APPLICABLE PRODUCTS, MODELS, OPTIONS, AND OTHER DATA. INCLUDE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS. 2) SUBMIT THE NUMBER OF COPIES WHICH CONTRACTOR REQUIRES, PLUS 1COPY WHICH WILL BE RETAINED BY ARCHITECT, POTBELLY. 3) MODIFY PRODUCT DATA AND INSTALLATION INSTRUCTIONS TO DELETE INFORMATION WHICH IS NOT APPLICABLE TO THE WORK. 4) SUPPLEMENT STANDARD INFORMATION TO PROVIDE INFORMATION SPECIFICALLY APPLICABLE TO THE WORK. SAMPLES 1) SUBMIT SAMPLES AS SPECIFIED IN THE TECHNICAL SECTIONS. 2) INCLUDE IDENTIFICATION ON EACH SAMPLE, GIVING FULL INFORMATION. 3) SUBMIT THE NUMBER OF SAMPLES SPECIFIED IN THE TECHNICAL SECTIONS. WHERE QUANTITY IS NOT SPECIFIED, SUBMIT 3 SAMPLES. 4) SUBMIT SAMPLES TO ILLUSTRATE FUNCTIONAL CHARACTERISTICS OF THE PRODUCT, WITH INTEGRAL PARTS AND ATTACHMENT DEVICES. COORDINATE SUBMITTAL OF DIFFERENT CATEGORIES FOR INTERFACING WORK. SUSTAINABLE DESIGN AND CONSTRUCTION 1) FOR WORK UNDER EACH SUBCONTRACT OR SPECIFICATION SECTION, MAKE SUBMITTALS AS NECESSARY TO SUPPORT EACH APPLICABLE CREDIT, AS DESCRIBED IN SECTION 018113. 2) MAKE SUBMITTALS AS NECESSARY TO SUPPORT PROCEDURAL REQUIREMENTS, INCLUDING WASTE MANAGEMENT AND INDOOR AIR QUALITY MANAGEMENT PLANS, AS DESCRIBED IN SECTION 018113. B) BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 ARTICLE 32 - FINAL CLEANING SHEET TITLE ARCHITECTURAL SPECIFICATIONS SHEET NUMBER AS1.1 GENERAL A. SECTION INCLUDES: SUPPORTS FOR CEILING FINISHES AND FIXTURES.: B. SYSTEM DESCRIPTION 1) SUPPORT FRAMING SHALL BE STEEL UNLESS APPROVED OTHERWISE. USE PROPRIETARY CHANNEL SUPPORT SYSTEMS WITH SUPPLEMENTARY SHOP FABRICATED STEEL SECTIONS AS APPROPRIATE TO THE INSTALLATION. 2) CONFIGURATIONS: SIZE MEMBERS AND SELECT ANCHORAGE SYSTEMS TO SUPPORT THE DEAD LOAD AS WELL AS LIVE OPERATIONAL LOADS; SAFETY FACTOR: 2.5 BASED ON ULTIMATE STRENGTH UNDER STATIC LOAD CONDITIONS. C. SUBMITTALS 1) PRODUCT LITERATURE. 2) SHOP DRAWINGS: SHOW DETAILS OF FABRICATION AND INSTALLATION; INDICATE MATERIALS, DIMENSIONS, ATTACHMENTS, PROPRIETARY CHANNEL SUPPORT SYSTEM PRODUCT NUMBERS, PROVISIONS FOR WORK OF OTHER TRADES, AND OTHER PERTINENT INFORMATION AS NECESSARY TO COORDINATE THE WORK. D. STRUCTURAL DESIGN: SUPPORTS FOR OVERHEAD EQUIPMENT NOT SPECIFICALLY INDICATED ON THE STRUCTURAL DRAWINGS SHALL BE DESIGNED BY A STRUCTURAL ENGINEER LICENSED TO PRACTICE IN THE STATE OF WASHINGTON. . 2. PRODUCTS A. PROPRIETARY CHANNEL SUPPORT SYSTEMS: 1) MANUFACTURER: UNISTRUT (SPOKANE, WA; 509-535-9841). 2) SYSTEM: P1000. 3) FINISH: "PERMA-GREEN" RUST INHIBITING ELECTRO-DEPOSITED ACRYLIC ENAMEL. 3. EXECUTION: A. INSTALL IN ACCORDANCE WITH THE APPROVED SHOP DRAWINGS. FREE FROM ADDED UREA-FORMALDEHYDE. H. FASTENERS 1) JOIST HANGERS: AS INDICATED. 2) LAG BOLTS: 3/8" X LENGTHS AS APPROPRIATE TO THE APPLICATION; UNFINISHED. 3) MISCELLANEOUS HARDWARE: FURNISH NAILS, WASHERS AND OTHER FASTENERS AS NECESSARY TO COMPLETE THE WORK. I. FABRICATION 1) SHOP FABRICATE ALL TRIM TO THE SHAPES INDICATED. 2) UNLESS OTHERWISE SCHEDULED, STANDING AND RUNNING TRIM TO RECEIVE OPAQUE FINISH MAY BE FABRICATED FROM MDF OR LUMBER AS SPECIFIED. 3) SHOP FIT AND ASSEMBLE TO THE GREATEST EXTENT PRACTICAL. 4) BACK OR KERF CUT ALL TRIM GREATER THAN 2 INCH IN WIDTH, EXCEPT TERMINATE BEFORE EXPOSED ENDS. 3. DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES 061000 - ROUGH CARPENTRY 1. 2. 3. GENERAL A. SECTION INCLUDES: 1) BLOCKING, NAILERS, AND CURBING. 2) PLYWOOD TERMINAL BACKBOARD 3) WATER HEATER PLATFORM B. SYSTEM DESCRIPTION BACKING: WHERE CONCEALED BACKING IS INDICATED OR REQUIRED IN STEEL FRAMED WALLS, PROVIDE WOOD OR METAL BACKING AT CONTRACTOR'S OPTION PRODUCTS A. DIMENSION LUMBER: IN ACCORDANCE WITH PS 20; STAMPED AND GRADED IN ACCORDANCE WITH WWPA OR WCLB GRADING RULES. 1) MOISTURE CONTENT: KILN DRIED TO 19% MAXIMUM MOISTURE CONTENT, EXCEPT FOR MATERIAL WHOSE LEAST DIMENSION IS 4 INCHES THICK OR GREATER. 2) SPECIES: HEM-FIR, SPRUCE-PINE-FIR (SPF), OR DOUGLAS FIR LARCH, UNLESS INDICATED OR SPECIFIED OTHERWISE. 3) UNEXPOSED NON-STRUCTURAL WOOD FRAMING AND BLOCKING GRADED AS FOLLOWS: A) MEMBERS 2" TO 4" THICK, 2" TO 4" WIDE: "NO 2 - STRUCTURAL LIGHT FRAMING," OR BETTER; "STUD" GRADE MAY BE USED AT STUD APPLICATIONS B) MEMBERS 2" TO 4" THICK, 5" AND WIDER: "NO. 2 - STRUCTURAL JOISTS AND PLANKS," OR BETTER. B. PLYWOOD BACKING(CONCEALED) AND SHEATHING: APA RATED SHEATHING; CD GRADE; EXTERIOR; PLYWOOD, UNLESS APPROVED OTHERWISE; THICKNESSES AS INDICATED. C. TERMINAL BACKBOARDS: APA AC GRADE EXTERIOR; FIRE RETARDANT TREATED. D. FASTENERS: 1) HOT-DIPPED GALVANIZED STEEL OR COPOLYMER COATED FOR EXTERIOR, HIGH HUMIDITY, AND TREATED WOOD LOCATIONS. 2) SCREWS: SELF TAPPING; COUNTERSUNK OR LOW PROFILE HEAD. E. FIRE RETARDANT TREATMENT: 1) FIRE RETARDANT TREAT ALL INTERIOR CONCEALED LUMBER AND PLYWOOD, AND OTHER WOOD AS INDICATED OR REQUIRED. 2) ALL FIRE RETARDANT TREATED WOOD MATERIALS SHALL BEAR A UL "FR-S" LABEL, OR A LABEL FROM AN APPROVED INSPECTION AGENCY CERTIFYING THAT THE MATERIAL MEETS THE REQUIREMENTS OF AWPA C_20 TYPE A FOR LUMBER AND AWPA C-27 TYPE A FOR PLYWOOD. 3) TREATED LUMBER SHALL BE KILN DRIED TO A MAXIMUM MOISTURE CONTENT OF 19%; TREATED PLYWOOD SHALL BE KILN DRIED TO A MAXIMUM MOISTURE CONTENT OF 15 PERCENT. 2. 3. 2. PRODUCTS A. FIREPROOFING MATERIAL: FURNISH ONE IF THE FOLLOWING, AS APPROPRIATE FOR PATCHING EXISTING FIREPROOFING. 1) ISOLATEK INTERNATIONAL "CAFCO 300," OR APPROVED CEMENTITIOUS FIREPROOFING. B. GENERAL A. SECTION INCLUDES: 1) STANDING AND RUNNING TRIM. 2) EXPOSED FRAMING 3) INSTALLATION OF OWNER FURNISHED WOODWORK B. SHOP DRAWINGS: FOR ITEMS FURNISHED UNDER THIS CONTRACT, INDICATE MATERIALS, COMPONENTS, PROFILES AND CONFIGURATIONS, DIMENSIONS, FASTENING METHODS, JOINTING DETAILS, COLORS AND FINISHES, AND ACCESSORIES. C. SPRAY APPLIED FIREPROOFING MATERIAL. QUALIFICATIONS: 1) REPLACEMENT FIREPROOFING MATERIAL SHALL HAVE BEEN TESTED AND REPORTED BY UL IN ACCORDANCE WITH PROCEDURES OF ASTM E119. 2) THE FIREPROOFING PRODUCT SHALL BE TESTED IN ACCORDANCE WITH ASTM STANDARD G_21_75, AND SHALL SHOW RESISTANCE TO MOLD GROWTH. MOLD INHIBITOR SHALL BE ADDED BY THE MANUFACTURER. A) SURFACE BURNING CHARACTERISTICS: IN ACCORDANCE WITH ASTM E84: B) FLAME SPREAD: 0 C) SMOKE DEVELOPMENT: 0 EXECUTION 1) PREPARATION A) VERIFY THAT ALL SURFACES TO RECEIVE SPRAYED REPLACEMENT FIREPROOFING ARE FREE OF FOREIGN SUBSTANCES WHICH MAY IMPAIR PROPER ADHESION OF THE FIREPROOFING TO THE PRODUCTS A. FACED BATT AND BLANKET INSULATION: 1) JOHNS MANVILLE CORP. "FSK_25," OWENS-CORNING FIBERGLAS CORP. "FLAME SPREAD 25," KNAUF INSULATION (800-825-4434) "ECOBATT FSK-FOIL FACED," OR APPROVED. ACCESSORIES TAPE: MATCH VAPOR RETARDER; 2 INCH WIDTH. 2) FURNISH OTHER ACCESSORIES, NOT SPECIFICALLY DESCRIBED, BUT REQUIRED FOR SECURE AND TIGHT INSTALLATION OF INSULATION WITH COMPLETE INSULATION FILL WITHIN CAVITIES, AND CONTINUOUS VAPOR RETARDER. E. ADHESIVE: 1) TYPE RECOMMENDED BY INSULATION MANUFACTURER FOR APPLICATION; COMPATIBLE WITH INSULATION AND SUBSTRATE. 2) TOXICITY/IEQ: COMPLY WITH APPLICABLE REGULATIONS REGARDING TOXIC AND HAZARDOUS MATERIALS, GS-36 FOR COMMERCIAL ADHESIVE AND SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. 3. 3. EXECUTION A. INSTALL INSULATION WITHOUT GAPS OR VOIDS. B. TRIM INSULATION NEATLY TO FIT SPACES. USE BATTS FREE OF DAMAGE. C. WALL INSULATION AND VAPOR RETARDER 1) AT METAL STUD FRAMING, INSTALL UNFACED BATT WITH EDGES TIGHTLY SET INTO THE STUD CHANNELS FOR A FRICTION FIT. PROVIDE ADDITIONAL SUPPORTS AS NECESSARY TO PREVENT SLIDING OF BATTS IN THE STUD CAVITY. 2) SEPARATE VAPOR BARRIER INSTALLATION: A) INSTALL SEPARATE VAPOR BARRIER OVER UNFACED INSULATION. B) INSTALL VAPOR BARRIER TOWARD WARM SIDE OF BUILDING SPACES. C) VAPOR BARRIER SHALL BE CONTINUOUS. D) AT LIGHTGAGE SUPPORT FRAMING, SECURE TO STUDS WITH DOUBLE STICK TAPE OR SPRAY ADHESIVE. E) LAP JOINTS IN VAPOR BARRIER 2 INCHES, EXCEPT PROVIDE TAPE SEALED JOINTS AT LOCATIONS WHERE VAPOR BARRIER WILL REMAIN EXPOSED IN THE FINISHED WORK. F) TAPE SEAL VAPOR BARRIER TO ADJACENT CONSTRUCTION AT PERIMETER EDGES. G) TAPE AND SEAL TEARS OR CUTS IN VAPOR BARRIER. D. CEILING INSULATION: INSTALL FACED BATTS OVER CEILING WITH ENDS AND EDGES TIGHTLY BUTTED WITHOUT GAPS. SECURE WITH ADHESIVE AS APPROPRIATE. E. SITE ENVIRONMENTAL PROCEDURES: 1) WASTE MANAGEMENT: AS SPECIFIED IN SECTION 018113 AND AS FOLLOWS: 2) COORDINATE WITH MANUFACTURER FOR TAKE-BACK PROGRAM. SET ASIDE SCRAP TO BE RETURNED TO MANUFACTURER FOR RECYCLING INTO NEW PRODUCT. GENERAL A. SECTION INCLUDES: FIRESTOPPING SYSTEMS FOR SEALING PENETRATIONS THROUGH FIRE-RATED CONSTRUCTION. B. PERFORMANCE REQUIREMENTS 1) EACH FIRESTOPPING SYSTEM SHALL BE SELECTED TO MAINTAIN FIRE RATING OF THE ASSEMBLY IN WHICH IT IS USED. 2) WHERE PENETRATION FIRESTOPPING IS USED TO SEAL PENETRATIONS THROUGH FLOORS WITH WATERPROOF MEMBRANES, SYSTEM SHALL BE SELECTED FOR COMPATIBILITY WITH MEMBRANE MATERIAL. 3) PROVIDE PRODUCTS THAT UPON CURING, DO NOT RE-EMULSIFY, DISSOLVE, LEACH, BREAKDOWN OR OTHERWISE DETERIORATE OVER TIME FROM EXPOSURE TO ATMOSPHERIC MOISTURE, SWEATING PIPES, PONDING WATER OR OTHER FORMS OF MOISTURE CHARACTERISTIC DURING AND AFTER CONSTRUCTION. 4) PROVIDE FIRESTOP SEALANTS SUFFICIENTLY FLEXIBLE TO ACCOMMODATE MOTION SUCH AS PIPE VIBRATION, WATER HAMMER, THERMAL EXPANSION AND OTHER NORMAL BUILDING MOVEMENT WITHOUT DAMAGE TO THE SEAL. 5) PIPE INSULATION SHALL NOT BE REMOVED, CUT AWAY OR OTHERWISE INTERRUPTED THROUGH WALL OR FLOOR OPENINGS. PROVIDE PRODUCTS APPROPRIATELY TESTED FOR THE THICKNESS AND TYPE OF INSULATION UTILIZED. 6) OPENINGS WITHIN WALLS AND FLOORS DESIGNED TO ACCOMMODATE VOICE, DATA AND VIDEO CABLING SHALL BE PROVIDED WITH RE-ENTERABLE PRODUCTS SPECIFICALLY DESIGNED FOR RETROFIT. 7) PENETRATIONS THROUGH FIRE-RESISTANCE RATED FLOOR-CEILING ASSEMBLIES CONTAINED WITHIN CHASE WALL ASSEMBLIES SHALL BE STRIKE REINFORCEMENT: MINIMUM 16 GAGE. CLOSER REINFORCEMENT: MINIMUM 14 GAGE. 5) FABRICATION A) CUT MORTISES FOR BUTTS STRIKES AND OTHER HARDWARE. PROJECTION WELD HINGE AND STRIKE REINFORCEMENTS TO THE DOOR FRAME. PROVIDE ADEQUATE REINFORCEMENTS FOR OTHER HARDWARE AS REQUIRED. B) FRAMES SHALL BE SHOP ASSEMBLED; CONTINUOUS FACE WELD JOINT BETWEEN THE HEAD AND JAMB FACES. C) GRIND AND FINISH SMOOTH FACE JOINTS WITH NO VISIBLE FACE SEAMS. C. FINISH: MANUFACTURER'S STANDARD RUST INHIBITIVE DIRECT TO METAL PRIMER. 1) METAL DOORS A) MANUFACTURE'S PRIMER B) G.C. TO PAINT IN FIELD PER DOOR SCHEDULE ON A2.0, 2 COATS, OR AS MANY AS REQUIRED FOR FULL COVERAGE. 2) WOOD DOORS 1) ONE COAT OF THE ST-02 STAIN. 2) ONE COAT OF THE SHER-WOOD KEMA AQUA 60 DEGREE SELF-SEAL AND TOP COAT (SHERWIN WILLIAMS ITEM #M64WXC6146). 3) LIGHT SAND / SCUFF (WIPE CLEAN). 4) ONE LAST COAT OF SHER-WOOD KEMA AQUA 60 DEGREE SELF-SEAL AND TOP COAT (SHERWIN WILLIAMS ITEM #M64WXC6146). OLDCASTLE BUILDINGENVELOPE "NS-212 STANDARD DUTY NARROW STILE." D) CRL/US ALUMINUM "SERIES 250 ENTRANCE DOORS." 3) ACCESSORIES: A) FURNISH INSIDE MOUNT COMPENSATION HEAD CHANNELS. B) TRANSOM DECAL: ("THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS") C) FURNISH SILLS, FASTENERS, ALUMINUM FLASHINGS, WATER DIVERTERS, SPACERS, GASKETS, SEALANTS, AND ADAPTERS AS NECESSARY FOR A COMPLETE INSTALLATION. 4) DOOR HARDWARE: A) WEATHERSTRIPPING: MANUFACTURER'S STANDARD POLY PILE IN DOOR AND/OR FRAME. B) OTHER OPERATING HARDWARE: AS SCHEDULED ON THE DRAWINGS. D. MATERIALS 1) EXTRUDED ALUMINUM: ANSI/ASTM B221; 6063-T5 ALLOY AND TEMPER. 2) SHEET ALUMINUM: ASTM B209, MINIMUM .019 INCH THICKNESS FOR C) B) C) EXECUTION A. PROVIDE FIRESTOPPING AT MECHANICAL, ELECTRICAL, AND PLUMBING PENETRATIONS THROUGH FIRE RATED FLOORS, WALLS, AND CEILINGS. B. WHERE FIRESTOPPING IS USED TO SEAL AROUND PENETRATIONS THROUGH WATERPROOF MEMBRANES, INSTALL TO MAINTAIN INTEGRITY OF WATERPROOF BARRIER. C. FOR SEALING ELECTRICAL BOXES, COORDINATE INSTALLATION WITH DIVISION 26. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION AND INSTALLATION. INSTALL IN LOCATIONS AS REQUIRED BY CODE FOR PROTECTION OF OPENINGS THROUGH FIRE RATED PARTITIONS. D. FILL OPEN HOLES WHICH REMAIN AFTER REMOVAL OF EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING COMPONENTS. PATCH AND REPAIR HOLES AS NECESSARY TO MATCH THE ADJACENT CONSTRUCTION AND TO MAINTAIN THE FIRE RATING OF THE ASSEMBLIES. FIRESTOPPING SYSTEMS MAY BE USED TO FILL HOLES WHICH WILL BE CONCEALED IN THE FINISH CONSTRUCTION. D. APPLICATIONS. GLAZING: FURNISHED UNDER SECTION 088000. PROVIDE SHOP GLAZED UNITS AT CONTRACTOR'S OPTION. E. FINISH: COLOR ANODIZED: AAMA AA-M12C22A44; ARCHITECTURAL CLASS I, ETCHED, MEDIUM MATTE, COLORED ANODIC COATING, 0.7 MIL THICKNESS; DARK BRONZE ANODIZED, UNLESS OTHERWISE DIRECTED OR REQUIRED TO MATCH EXISTING. 3) 3. EXECUTION: INSTALL FRAMES IN ACCORDANCE WITH ANSI A250.11 2) DOOR INSTALLATION IS SPECIFIED IN SECTION 087103. 1) EXECUTION A. INSTALL FRAMING IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. INSTALL SILL PAN IN ROUGH OPENING WITH END DAMS TIGHT TO THE JAMB FRAMING MEMBERS. PROVIDE SOLID BLOCKING AND ENSURE THAT THE SILL PAN IS SLOPED TO DRAIN. COORDINATE INSTALLATION TO ACCOMMODATE INSTALLATION OF FLEXIBLE FLASHING AND BUILDING PAPER ELEMENTS FLASHED TO WEATHER. C. WHERE COMPENSATING HEAD CHANNELS ARE USED, SCREW CHANNELS TO STRUCTURE WITH CENTER OF CHANNEL FIXED AND OTHER FASTENERS THROUGH SLOTTED HOLES. D. SCREW ATTACH END DAMS TO SUB-SILL ENDS; SEAL JOINTS BETWEEN DAM AND SUB-SILL. FASTEN THE SUB-SILL SECURELY INTO THE OPENINGS. CAP SEAL TOPS OF FASTENERS. E. COORDINATE INSTALLATION OF DOORS AND HARDWARE, AS SPECIFIED IN SECTION 087301. 087103 - DOOR HARDWARE AND INSTALLATION 1. GENERAL: A. SECTION INCLUDES: SEALANTS FOR INSTALLATION AT INTERIOR NON-MOVING JOINTS, CERAMIC TILE EXPANSION JOINTS, AND AS NECESSARY TO SEAL JOINTS AROUND CASEWORK AND PLUMBING FIXTURES. 2. PRODUCTS: A. SEALANTS: 1) TYPE PTNS: ASTM C920, TYPE M, GRADE NS, CLASS 25; PECORA "DYNATRED," TREMCO "HPL," OR APPROVED; STANDARD COLOR AS SELECTED FROM THE MANUFACTURER'S COMPLETE LINE OF PRE-FORMULATED COLORS. 2) TYPE A: ASTM C834; TREMCO "ACRYLIC LATEX CAULK," PECORA "AC-20+SILICONE," SONNEBORN "SONOLAC," OR APPROVED; STANDARD COLORS TO MATCH ADJACENT CONSTRUCTION. 3) TYPE S - NEUTRAL CURE SILICONE SEALANT: DOW CORNING, "790 SILICONE BUILDING SEALANT," "795 SILICONE STRUCTURAL GLAZING AND WEATHERPROOFING SEALANT," OR "CONTRACTORS WEATHERPROOFING SEALANT"; PECORA "890 FTS SILICONE;" OR TREMCO INC. "SPECTREM 3." 4) TYPE SM: MILDEW RESISTANT SILICONE SEALANT: USDA APPROVED; DOW CORNING "786," GE "SANITARY SCS1700," OR APPROVED; TRANSLUCENT OR WHITE, AS SCHEDULED. B. PRIMER: AS RECOMMENDED BY RESPECTIVE MANUFACTURERS FOR EACH APPLICATION. C. BACKER ROD: CLOSED OR OPEN CELL FOAM AS RECOMMENDED BY THE SEALANT MANUFACTURER FOR THE APPLICATION; ROUND PROFILE; THICKNESS APPROXIMATELY 130 PERCENT OF JOINT WIDTH. 3. 078413 - PENETRATION FIRESTOPPING 1. PRODUCTS A. SYSTEMS MEETING THE REQUIREMENTS SPECIFIED AND SUITABLE FOR THE CONDITIONS INDICATED AS MANUFACTURED BY ONE OR MORE OF THE FOLLOWING. 1) METACAULK. 2) TREMCO INC. 3) HILTI USA. 4) GRACE CONSTRUCTION PRODUCTS. 5) SPECIFIED TECHNOLOGIES, INC. 6) 3M. B. ELECTRICAL BOX INSERTS: 1) MANUFACTURER: RECTORSEAL (HOUSTON TX; 713_263_8001; 800_231_3345). 2) FIRE RATED PADS: "BIOFIRESHIELD LECTRA-STOP"; 1/4 INCH THICK INTUMESCENT PADS; SIZED TO FIT ELECTRICAL BOXES; CLASSIFIED BY UL; MINIMUM 2 HOUR RATING. 079200 - JOINT SEALANTS 1) 070183 - REPLACEMENT FIREPROOFING GENERAL A. SECTION INCLUDES: 1) SURFACE PREPARATION AND COORDINATION WORK FOR PATCHING OF EXISTING AND INCIDENTAL NEW FIREPROOFING WORK. 2) FIREPROOFING MATERIALS. 3) SEALING OF EXISTING FIREPROOFING INDICATED TO REMAIN EXPOSED IN THE FINISHED WORK. B. SUBMITTALS: MANUFACTURERS' DATA; INCLUDE INSTRUCTIONS FOR PROPER APPLICATION OF SPRAYED REPLACEMENT FIREPROOFING. C. QUALITY ASSURANCE 1) FIREPROOFING WORK SHALL BE PERFORMED BY A FIRM ACCEPTABLE TO THE SPRAYED REPLACEMENT FIREPROOFING MATERIALS MANUFACTURER. 2) PRODUCTS, EXECUTION AND FIREPROOFING THICKNESSES SHALL CONFORM TO THE APPLICABLE CODE REQUIREMENTS FOR THE FIRE-RESISTANCE RATINGS CALLED FOR. 2. D. DIVISION 07 - THERMAL AND MOISTURE PROTECTION 1. GENERAL A. SECTION INCLUDES: 1) THERMAL BATT AND BLANKET INSULATION. 2) VAPOR RETARDER. B. PRODUCT DATA: SUBMIT FOR EACH TYPE OF INSULATION AND VAPOR RETARDER. GLASS FIBER ROLL WITH FOIL SCRIM KRAFT FACE; FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPED OF 50 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84. 3) MINIMUM 20 PERCENT CALCULATED (BASED ON SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER) RECYCLED CONTENT. 4) THICKNESS AS NECESSARY TO ACHIEVE MINIMUM R-13 THERMAL RESISTANCE. B. UNFACED BATT AND BLANKET INSULATION: 1) JOHNS MANVILLE CORP. "UNFACED FORMALDEHYDE-FREE THERMAL AND ACOUSTICAL FIBER GLASS INSULATION," KNAUF INSULATION (800-825-4434) "ECOBATT," OR APPROVED. 2) ASTM C665, TYPE I; PREFORMED UNFACED GLASS FIBER BATTS; FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPED OF 50 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84. 3) UNFACED FORMALDEHYDE-FREE GLASS FIBER COMMERCIAL INSULATION; OVERSIZE WIDTHS FOR FRICTION-FIT BETWEEN METAL FRAMING MEMBERS; MINIMUM 20 PERCENT CALCULATED (BASED ON SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER) RECYCLED CONTENT. 4) THICKNESS AS INDICATED ON THE DRAWINGS. C. VAPOR RETARDER: CERTAINTEED CORPORATION (VALLEY FORGE PA; 610_341_7000; 800_233_8990) "MEMBRAIN"; 2 MIL POLYAMIDE FILM; FLAME EXECUTION A. INSTALL CASEWORK AS DIRECTED. B. COORDINATE WITH OWNER TO ACCOMMODATE CASEWORK INSTALLATION, AS NECESSARY. 062213 - INTERIOR FINISH CARPENTRY PRODUCTS A. CONCEALED FRAMING LUMBER: PINE, FIR, HEMLOCK, OR OTHER SPECIES AS APPROVED; MAXIMUM MOISTURE CONTENT 10 PERCENT. B. EXPOSED LUMBER FOR OPAQUE FINISH: ALDER, POPLAR OR SIMILAR APPROVED HARDWOOD; AWS CUSTOM GRADE. C. EXPOSED FRAMING LUMBER: PS20; SELECT B&BTR. TO MEET THE HOURLY FIRE RATINGS OF THE CONSTRUCTION BEING SEALED. PROVIDE F RATED ASSEMBLIES, EXCEPT WHERE T RATED ASSEMBLIES ARE REQUIRED BY THE CODE AUTHORITY. 2) PRODUCTS A. FURNISH WOOD AND STEEL BLOCKING AS SPECIFIED IN SECTION 092200. B. COORDINATE WITH OTHER TRADES AS NECESSARY FOR PROPER INCORPORATION OF UTILITIES AND INTERFACE WITH FINISHES. 2) 2. 2. EXECUTION A. INSTALLATION 1) JOINTING: MAKE ALL JOINTS TO CONCEAL SHRINKAGE; MITER ALL EXTERIOR CORNERS; COPE ALL INTERIOR CORNERS, MITER OR SCARF ALL END-TO-END JOINTS; INSTALL ALL TRIM PIECES AS LONG AS POSSIBLE, JOINTING ONLY WHERE SOLID SUPPORT IS OBTAINED. MAKE NO JOINTS CLOSER THAN 4 FEET TO CORNERS. 2) LENGTHS OF MATERIAL: USE RANDOM LENGTHS AND SHOW TYPICAL JOINT LOCATIONS ON SHOP DRAWINGS. THE MINIMUM LENGTH SHALL BE 8 FEET, EXCEPT WHERE SHORT LENGTHS ARE REQUIRED BY INSTALLATION CONDITIONS. 3) FASTENING: A) INSTALL ALL ITEMS STRAIGHT, TRUE, LEVEL, PLUMB, AND FIRMLY ANCHORED IN PLACE; WHERE BLOCKING OR BACKING IS REQUIRED, COORDINATE AS NECESSARY WITH OTHER TRADES TO ENSURE PLACEMENT OF ALL REQUIRED BACKING AND BLOCKING IN A TIMELY MANNER. B) FASTEN TRIM WITH FINISH NAILS OR TRIM HEAD SCREWS OF PROPER DIMENSION TO HOLD THE MEMBER FIRMLY IN PLACE WITHOUT SPLITTING THE WOOD. C) ON EXPOSED FINISH WORK, SET ALL NAILS AND SCREWS. D) ALIGN EXPOSED FASTENERS FOR UNIFORM PATTERN; RANDOM OR "SHOTGUN" PATTERNS WILL NOT BE ACCEPTED. B. PUTTY FILL ALL EXPOSED FASTENER HOLES AND LEVEL WITH SURFACE. FOR TRIM INDICATED FOR TRANSPARENT FINISH; USE COLOR MATCHED PUTTY; SEQUENCE WITH FINISHING TO AVOID SOLVENT STAINING. GENERAL A. SECTION INCLUDES: 1) INSTALLATION OF OWNER FURNISHED CASEWORK AND SHELVING. 2) COORDINATION WITH OWNER FOR INSTALLATION OF CASEWORK BY THE OWNER AND/OR OWNER'S VENDOR. B. SHOP DRAWINGS: INDICATE LOCATIONS OF WALL MOUNTED CASEWORK AND BLOCKING. C. OBTAIN TEMPLATES, SHOP DRAWINGS, AND INSTALLATION INSTRUCTIONS FROM OWNER'S VENDOR(S), AS NECESSARY TO FACILITATE PROPER INSTALLATION. 1. A. 1. 1. 064100 - ARCHITECTURAL CASEWORK EXECUTION FRAMING HAS BEEN CONFIGURED OR DESIGNED TO SUPPORT RESPECTIVE COMPONENTS, INSTALL WOOD BLOCKING TO RECEIVE MECHANICAL FASTENERS FOR SUPPORT OF PLUMBING AND ELECTRICAL FIXTURES AND EQUIPMENT, CABINETS, DOOR STOP PLATES, WOOD BASE, WAINSCOTS, COAT HOOKS, TOILET AND BATH ACCESSORIES, AND ALL OTHER WALL AND CEILING MOUNTED COMPONENTS. B. SCREW FASTEN WOOD COMPONENTS TO METAL FRAMING AND SUPPORT ELEMENTS. C. FOR ATTACHMENT OF PLYWOOD BACKING, KERF PLYWOOD 1/4" (3/8", MAXIMUM IF REQUIRED FOR HEAVY GAGE STUDS) TO RECEIVE FLANGE RETURN (OR CRIMP THE RETURN CLOSED); PROVIDE SUPPLEMENTARY SHEET METAL ANGLE ATTACHED TO BACK OF STUD WHERE NECESSARY TO SUPPORT BACKING. SCREWS INTO EDGE OF PLYWOOD ARE UNACCEPTABLE. 2) 072117 - FIBROUS BUILDING INSULATION 3) UNIVERSAL NON-HANDED PREPARATION OF DOORS IS NOT ACCEPTABLE. INSTALL REINFORCEMENTS, WELDED IN PLACE. D) REINFORCE TOP AND BOTTOM OF DOORS WITH 14 GAGE CHANNELS, WELDED TO BOTH FACE PANELS. B. FRAME 1) ANSI A250.8; DOUBLE EQUAL RABBET, UNLESS INDICATED OTHERWISE. 2) MATERIAL: COLD-ROLLED STEEL, ASTM A1008; MINIMUM 16 GAGE (.053 INCH) 3) ACCESSORIES: FURNISH NECESSARY ANCHORS FOR JAMBS, HEADS, AND SILLS OF ASSEMBLIES. 4) FRAME HARDWARE REINFORCEMENTS A) MORTISE HINGE REINFORCEMENT: MINIMUM 7 GAGE: FURNISH HIGH FREQUENCY HINGE REINFORCEMENT FOR TOP HINGE ON ALL EXTERIOR, CROSS CORRIDOR, AND STAIRWELL FRAMES, IN PROTECTED WITH PRODUCTS TESTED BY BEING FULLY EXPOSED TO THE FIRE OUTSIDE OF THE CHASE WALL. C. QUALITY ASSURANCE 1) CODE VERIFICATION: PRIOR TO INSTALLATION OF FIRE STOPPING SYSTEMS OBTAIN APPROVAL FROM THE JURISDICTIONAL CODE AUTHORITIES FOR THE FIRE STOPPING SYSTEMS AND APPLICATIONS PROPOSED. B) EXECUTION: A. PERFORM WORK IN ACCORDANCE WITH ASTM C1193, UNLESS SPECIFIED OTHERWISE OR RECOMMENDED OTHERWISE BY THE SEALANT MANUFACTURER. B. TOOLING: TOOL JOINTS CONCAVE, UNLESS INDICATED OR SPECIFIED OTHERWISE. FINISH FREE OF AIR POCKETS, FOREIGN EMBEDDED MATTER, RIDGES, AND SAGS. C. SCHEDULE: 1) TYPE A: PROVIDE AT INTERIOR JOINTS, UNLESS SPECIFIED OTHERWISE. 2) TYPE PTNS: INSTALL IN FLOOR AND WALL TILE EXPANSION JOINTS, FULL DEPTH WITHOUT BACKER ROD; COLOR MATCHED TO GROUT IN TILE LOCATIONS, AS SELECTED BY THE ARCHITECT FOR OTHER LOCATIONS.. 3) TYPE S: PROVIDE AT EXTERIOR NON-TRAFFIC JOINTS; BLACK COLOR AT ALUMINUM FRAMING PERIMETERS; AS DIRECTED AT OTHER LOCATIONS. 4) TYPE SM: PROVIDE AT JOINTS BETWEEN WALLS, COUNTERS OR FLOORS AND PLUMBING FIXTURES OR TOILET ACCESSORIES, AND AT COUNTER TO WALL JOINTS WHERE PLUMBING FIXTURES ARE INSTALLED IN THE COUNTER WHERE SEALANT IS REQUIRED OR INDICATED. USE WHITE AGAINST WHITE PLUMBING FIXTURES; TRANSLUCENT FOR ALL OTHER APPLICATIONS. DIVISION 08 - OPENINGS 081200 - HOLLOW METAL DOOR AND FRAME 1. GENERAL A. SECTION INCLUDES: ROLLED STEEL DOOR AND FRAME 2. PRODUCTS A. INTERIOR DOORS: 1) FACE SHEET MATERIAL: COLD-ROLLED STEEL, A 1008, 18 GAGE RECYCLED CONTENT: MINIMUM 35 PERCENT BASED ON SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER RECYCLED CONTENT. 3) CORE: STIFFENED, AND SOUND DEADENED WITH IMPREGNATED KRAFT HONEYCOMB CORE COMPLETELY FILLING THE INSIDE OF THE DOORS AND LAMINATED TO INSIDE FACES OF BOTH PANELS. 4) DOOR HARDWARE REINFORCEMENTS: A) HINGE REINFORCEMENTS FOR FULL MORTISE HINGES: MINIMUM 7 GAGE. B) LOCK REINFORCEMENTS: MINIMUM 16 GAGE 2) C) 5) FABRICATION: A) IN ACCORDANCE WITH ASNI A250.8; SEAMLESS; WELDED AND/OR EPOXY FILLED AT FABRICATOR'S OPTION; GRIND SMOOTH. B) BEVEL DOOR LATCH EDGES 1/8 INCH IN 2 INCHES. C) CUT MORTISES FOR BUTTS USING APPROPRIATE TEMPLATES; 081433 - STILE AND RAIL WOOD DOORS 1. GENERAL A. SECTION INCLUDES: INSTALLATION OF STILE AND RAIL WOOD DOORS AS SCHEDULED. B. SUBMITTALS: REQUIRE AS NECESSARY TO COORDINATE THE WORK. 2. PRODUCTS A. STILE AND RAIL TYPE DOORS: FURNISHED BY THE OWNER 3. EXECUTION A. INSTALLATION: SPECIFIED IN SECTION 087103. 1. GENERAL A. SECTION INCLUDES: 1) CONTRACTOR-FURNISHED HARDWARE FOR SWINGING DOORS (EXCEPT AS SPECIFIED AS PART OF THE DOOR PACKAGE). 2) DOOR AND HARDWARE INSTALLATION. B. SUBMITTALS: SUBMIT THE FOLLOWING FOR HARDWARE TO BE FURNISHED UNDER THIS CONTRACT. 1) PRODUCT DATA 2) HARDWARE SCHEDULE: 4 COPIES WITH DESCRIPTION OF EACH HARDWARE GROUP. INDICATE THE FOLLOWING A) TYPE, STYLE, FUNCTION, SIZE, QUANTITY AND FINISH OF HARDWARE ITEMS. B) NAME, PART NUMBER AND MANUFACTURE OF EACH ITEM. C) FASTENINGS AND OTHER PERTINENT INFORMATION. D) EXPLANATION OF ABBREVIATIONS, SYMBOLS AND CODES CONTAINED IN SCHEDULE. E) DOOR AND FRAME SIZES, MATERIALS AND DEGREES OF SWING. 3) WIRING/RISER DIAGRAMS AS APPROPRIATE TO THE WORK. C. INSTALLER QUALIFICATIONS: INSTALLER: COMPANY WITH QUALIFIED PERSONNEL, WITH NOT LESS THAN 3 YEARS EXPERIENCE IN INSTALLATION OF WORK SIMILAR IN SCOPE TO THAT OF THIS PROJECT. 2. PRODUCTS A. MANUAL SWINGING DOOR HARDWARE: FURNISHED BY THE OWNER. B. TYPE: AS SCHEDULED ON THE DRAWINGS 3. EXECUTION A. DOOR INSTALLATION 1) MAINTAIN CLEARANCES OF 1/8 INCH AT JAMBS AND HEADS, AND 1/2 INCH FROM BOTTOM OF DOOR TO TOP OF DECORATIVE FLOOR FINISH OR COVERING, EXCEPT WHERE THRESHOLD IS FURNISHED, PROVIDE 1/4-INCH CLEARANCE FROM BOTTOM OF DOOR TO TOP OF THRESHOLD. 2) INSTALL DOORS TO OPERATE FREELY, BUT NOT LOOSELY, FREE FROM HINGE BOUND CONDITIONS, STICKING OR BINDING. DO NOT INSTALL IN FRAMES WHICH WOULD HINDER OPERATION OF DOORS. 3) ENSURE DOORS ARE FREE FROM RATTLING WHEN IN LATCHED POSITION. B. FINISH HARDWARE INSTALLATION 1) INSTALL HARDWARE PLUMB, LEVEL AND TRUE TO LINE IN ACCORDANCE WITH MANUFACTURER'S TEMPLATES, PRINTED INSTRUCTIONS AND PROJECT CONDITIONS. 2) INSTALL HARDWARE UNITS TO MATCH BUILDING STANDARD MOUNTING HEIGHTS. FOR NEW CONSTRUCTION, MOUNT HARDWARE AS DETAILED. WHERE NOT DETAILED, MOUNT IN ACCORDANCE WITH ADA REQUIREMENTS AND DHI RECOMMENDATIONS. C. ADJUSTMENT: ADJUST AND CHECK FOR PROPER OPERATION AND FUNCTION. REPLACE UNITS, WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY 0844113 - ALUMINUM FRAMED ENTRANCES AND STOREFRONTS 1. 2. GENERAL A. SECTION INCLUDES: 1) EXTERIOR AND INTERIOR STICK FRAMED ALUMINUM STOREFRONT SYSTEMS. 2) ALUMINUM AND GLASS ENTRANCES. B. PROFILES: FRAMING MEMBER PROFILES, AS INDICATED IN THE DRAWINGS, INDICATE PROPORTIONS AND INTENT. MINOR VARIATIONS IN PROFILES, ASSEMBLIES, AND CONNECTIONS WILL BE ACCEPTED, PROVIDED THAT, IN THE OPINION OF THE ARCHITECT, THEY DO NOT SUBSTANTIALLY ALTER THE INTENDED APPEARANCE. C. SUBMITTALS 1) SHOP DRAWINGS: INCLUDE WALL OPENING DIMENSIONS, COMPONENT DIMENSIONS, TOLERANCES REQUIRED, ANCHORAGES AND FASTENERS, RELATIONSHIP TO ADJACENT CONSTRUCTION, THRESHOLD CONFIGURATIONS, INSTALLATION DETAILS, FLASHINGS, AND SEALANT LOCATIONS. 2) SAMPLES: SUBMIT THREE SAMPLES OF A TYPICAL EXTRUSION FINISHED WITH SYSTEM AND COLOR PROPOSED FOR THE FINISHED WORK; 12 INCH MINIMUM LENGTH. D. GUARANTEE AND WARRANTY 1) MANUFACTURER'S WARRANTY: 3-YEAR WRITTEN WARRANTIES EXECUTED TO THE OWNER, FROM THE MANUFACTURERS OF THE STOREFRONT AND ALUMINUM WINDOW SYSTEMS, AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. 2) INSTALLER'S GUARANTEE: 3_YEAR WRITTEN GUARANTEE AGAINST DEFECTS IN INSTALLATION. PRODUCTS A. EXISTING SYSTEMS: WHERE FRAMING SYSTEMS ARE INDICATED FOR RECONFIGURATION OR EXTENSION OF EXISTING, MATCH EXISTING. B. NEW FRAMING SYSTEMS: ONE OF THE FOLLOWING, OR APPROVED. FURNISH SCREW-SPLINE, SHEAR BLOCK OR STICK ASSEMBLY AT CONTRACTOR'S OPTION. 1) KAWNEER NORTH AMERICA A) EXTERIOR: TRIFAB VERSAGLAZE 451T; 2" X 4-1/2" SECTION; THERMAL BREAK DESIGN; CENTER GLAZED. B) INTERIOR: TRIFAB 400; 1-3/4"X4" SECTION, CENTER GLAZED. 2) ARCADIA. A) EXTERIOR: AG451T; 2" X 4-1/2" SECTION; THERMAL BREAK DESIGN; CENTER GLAZED. B) INTERIOR: A400; 1-3/4"X4" SECTION, CENTER GLAZED. 3) OLDCASTLE BUILDINGENVELOPE. A) EXTERIOR: SERIES 3000 THERMAL MULTIPLANE - CENTER SET; 2" X 4-1/2" SECTION; THERMAL BREAK DESIGN; CENTER GLAZED. B) INTERIOR: FG-1000; 1-3/4"X4" SECTION, CENTER GLAZED. 4) CRL/US ALUMINUM. A) EXTERIOR: IT451; 2" X 4-1/2" SECTION; THERMAL BREAK DESIGN; CENTER GLAZED. B) INTERIOR: SERIES 400; 1-3/4"X4" SECTION, CENTER GLAZED. C. ENTRY DOORS: 1) EXTERIOR: HEAVY DUTY MEDIUM STILE; 10 INCH NOMINAL BOTTOM FOLLOWING, OR APPROVED. A) KAWNEER NORTH AMERICA "350 HEAVY WALL ENTRANCE." B) ARCADIA "MS362 HD HEAVY DUTY MEDIUM STILE ENTRANCE DOOR." C) OLDCASTLE BUILDINGENVELOPE "RUGGED MEDIUM STILE." D) CRL/US ALUMINUM "SERIES 800 DURAFRONT." 2) INTERIOR: NARROW STILE; 10 INCH NOMINAL BOTTOM RAIL; STOPS A R 4 0 4 S. C Wells H I S t ., T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R 1. GENERAL A. SECTION INCLUDES: 1) VISION LITES FOR DOORS. 2) INTERIOR WINDOW GLAZING. 3) GLAZING FOR EXTERIOR STOREFRONTS. B. QUALITY ASSURANCE: COMPLY WITH PERTINENT RECOMMENDATIONS IN THE GANA "MANUAL OF GLAZING." 2. PRODUCTS A. CLEAR GLASS: ASTM C1036, TYPE I, CLASS 1(CLEAR), QUALITY Q3 GLAZING TEMPERED GLASS: ASTM C1048; FULLY TEMPERED. C. INSULATING GLASS UNITS: 1) EXISTING: WHERE GLAZING IS INDICATED IN RECONFIGURED OR EXTENDED STOREFRONT SYSTEM (UNLESS ENTRANCE STOREFRONT GLAZING IS INDICATED TO BE REPLACED WITH NEW), MATCH EXISTING GLAZING TYPE. 2) NEW STOREFRONT: 2 LAYERS OF 1/4 INCH CLEAR TEMPERED GLASS WITH 1/2 INCH AIRSPACE; LOW-E COATING TO THE #2 SURFACE; ONE OF THE FOLLOWING. B. A) VIRACON "VNE63." D. SETTING BLOCKS: NEOPRENE; 70-90 SHORE A DUROMETER HARDNESS; 4 INCHES LONG X 1/4 HIGH X WIDTH AS REQUIRED FOR APPLICATION INDICATED. C) S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 SECTION 088000 - GLAZING B) APPROVED. A) KAWNEER NORTH AMERICA "190 STANDARD ENTRANCE." B) ARCADIA "NS212 SERIES NARROW STILE ENTRANCE DOOR." 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM PROJECT NUMBER: 16-059 055023 - OVERHEAD SUPPORT FRAMING 1. SUBSTRATE. VERIFY THAT WORK OF OTHER TRADES HAS PROGRESSED TO THE POINT WHERE REPLACEMENT FIREPROOFING INSTALLATION CAN BEGIN. 2) APPLICATION: ALL PATCHING AND REPAIRING OF SPRAYED REPLACEMENT FIREPROOFING DUE TO REMOVAL AS NECESSARY TO ACCOMMODATE NEW CONSTRUCTION, AND DAMAGE BY THE OTHER TRADES, SHALL BE PERFORMED UNDER THIS SECTION. PREFABRICATED TRIM: AS SCHEDULED; FURNISHED BY OWNER UNLESS OTHERWISE SCHEDULED. E. TAMBOUR: AS SCHEDULED. F. CEDAR: FURNISHED BY THE OWNER 1) MDO (SMOOTH) PLYWOOD: APA RATED, GROUP 1, B-C OR BETTER; MDO FACE. G. MEDIUM DENSITY FIBERBOARD (MDF): 1) ANSI A208.2 CLASS MD (MEDIUM DENSITY). 2) MOISTURE RESISTANT MDF: SIERRA PINE LTD. (800 676 3339) "MEDEX"; D. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 3. EXECUTION: A. INSTALL METAL FABRICATIONS IN ACCURATE LOCATIONS SHOWN. UNLESS INDICATED OTHERWISE, FABRICATIONS SHALL BE INSTALLED PLUMB AND LEVEL. SHEET TITLE ARCHITECTURAL SPECIFICATIONS SHEET NUMBER AS1.2 SCHEDULE: INDICATED ON THE DRAWINGS. DIVISION 09 - FINISHES 092200 - LIGHTGAGE METAL SUPPORT FRAMING 1. 2. GENERAL A. SECTION INCLUDES: 1) PARTITION FRAMING. 2) STEEL BACKING. 3) CEILING AND SOFFIT FRAMING. 4) FURRING. B. SYSTEM DESCRIPTION 1) STRUCTURAL DESIGN OF LIGHTGAGE METAL FRAMING SYSTEMS SHALL BE FURNISHED BY THE CONTRACTOR. 2) PARTITION FRAMING SHALL CONFORM TO THE WIDTHS INDICATED, UNLESS APPROVED OTHERWISE. PROVIDE THICKER GAGES AND DECREASED STUD SPACING AS NECESSARY TO MEET THE DESIGN REQUIREMENTS. 3) DESIGN LOADS: A) INTERIOR CEILING ASSEMBLIES: 5 PSF UNIFORM LIVE LOAD, PLUS DEAD LOADS. B) INTERIOR PARTITIONS: 5 PSF UNIFORM LIVE LATERAL LOAD PLUS WEIGHT OF WALL MOUNTED EQUIPMENT AND CASEWORK.. C) SEISMIC LOADS: SEISMIC DESIGN CATEGORY D. 4) DEFLECTION REQUIREMENTS: A) MAXIMUM DEFLECTION OF 1/240 FOR FLEXIBLE FINISH MATERIALS SUCH AS GYPSUM BOARD. B) MAXIMUM DEFLECTION OF 1/360 FOR RIGID FINISH MATERIALS SUCH AS CERAMIC TILE. C. QUALITY ASSURANCE: UNLESS INDICATED OTHERWISE, PERFORM WORK IN PRODUCTS A. NON-LOAD BEARING LIGHT GAGE METAL FRAMING: 1) FURNISH "C" SHAPED STUDS, DEPTHS AS INDICATED; ASTM C645; GALVANIZED; MINIMUM 25 GAGE (18 MIL). 2) FURNISH U SHAPED TRACKS (RUNNERS), HAT AND "Z" SHAPED FURRING CHANNELS, AND OTHER SIZES AND SHAPES AS INDICATED ON THE DRAWINGS, AND REQUIRED BY THE REFERENCED STANDARDS. 3) RECYCLED CONTENT: MINIMUM 10 PERCENT CALCULATED (BASED ON SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER) RECYCLED CONTENT. 4) PARTITION HEAD COMPENSATING CHANNEL (NON-FIRE RATED): DESIGN 1. 2. B) 3. EXECUTION A. INTERIOR PARTITION FRAMING 1) RUNNERS: A) SECURE RUNNERS WITH FASTENERS AT MAXIMUM 24 INCHES OC. B) TOP RUNNER: SECURE HEAD TRACK TO STRUCTURE WITH ALLOWANCE FOR STRUCTURAL DEFLECTION. (1) NON RATED PARTITIONS: USE PROPRIETARY COMPENSATING CHANNEL OR DEEP LEG TRACK AT CONTRACTOR'S OPTION, AS NECESSARY TO ACCOMMODATE BUILDING DEFLECTION. (2) FIRE RATED PARTITIONS: INSTALL PROPRIETARY FIRE RATED RUNNER AND ACCESSORIES AS NECESSARY TO MEET THE FIRE RATING REQUIREMENTS INDICATED ON THE DRAWINGS; COMPLY WITH UL REQUIREMENTS FOR LISTED ASSEMBLY. C) COORDINATE WITH SECTION 078100 FOR SEQUENCING AND PATCHING OF FIREPROOFING MATERIALS, AS NECESSARY TO MAINTAIN FIRE SEPARATION. 2) UNLESS INDICATED OTHERWISE, INSTALL STUDS VERTICALLY AT 24 INCHES O.C., AND NOT MORE THAN 2 INCHES FROM ABUTTING CONSTRUCTION, AT EACH SIDE OF OPENINGS, AND AT CORNERS. FIT RUNNERS UNDER AND ABOVE OPENINGS; SECURE INTERMEDIATE STUDS AT SPACING OF WALL STUDS. 4) BRACE PARTITION FRAMING SYSTEM AND MAKE RIGID. 5) INSTALL DOUBLE STUDS CONTINUOUS FROM FLOOR TO CEILING TRACK AT THE JAMB OF EACH DOOR FRAME AND CASED OPENING. STUDS SHALL BE NO LESS THAN 20 GAGE. PROVIDE DIAGONAL STEEL STUD BRACING TO STRUCTURE AT EACH JAMB AT PARTITIONS WHICH DO NOT EXTENT TO STRUCTURE. 6) AT NON-LOAD BEARING FULL HEIGHT PARTITIONS SUBJECT TO COMPRESSION CAUSED BY OVERHEAD STRUCTURAL DEFLECTION, AND WHERE PROPRIETARY COMPENSATING CHANNEL SYSTEM IS NOT USED, CUT STUDS 1/2 INCH SHORT FROM FULL HEIGHT. DO NOT RIGIDLY CONNECT STUD TO TOP RUNNER. 7) STUD BRIDGING: AT INTERIOR PARTITIONS GREATER THAN 4 FEET IN LENGTH, AND WITH RIGID FACING MATERIAL ON ONE STUD FLANGE ONLY, PROVIDE 3/4" BRIDGING CHANNELS IN HORIZONTAL ROWS AT A MAXIMUM OF 5'-0" O.C. FOR THE FULL HEIGHT OF THE PARTITION. B. BACKING 1) PROVIDE STEEL BACKING WHERE INDICATED. AT THE CONTRACTOR'S 3) 3. TRIM: USE LONGEST PRACTICAL LENGTHS, WITH NO PIECE LESS THAN 2 FEET LONG FOR CONTINUOUS RUNS GREATER THAN 8 FEET. SECURELY FASTEN AND ALIGN TRIM ENDS AT JOINTS. 2) PLACE CONCEALED FLANGE CORNER BEADS AT ALL EXTERNAL CORNERS. AT ANGLES OTHER THAN 90 DEGREES, BEND THE FLANGE TO CONFORM TO THE ANGLE. 3) PLACE CONCEALED FLANGE TYPE L TRIM WHERE GYPSUM BOARD ABUTS DISSIMILAR MATERIALS. 4) INSTALL CONTROL JOINT TRIM IN GYPSUM BOARD FIELDS WITH CONTINUOUS RUNS IN EXCESS OF 30 FEET, AND IN LOCATIONS AS DIRECTED E. FINISHING: 1) PROVIDE IN ACCORDANCE WITH GA 214. 2) WHERE NECESSARY TO SAND, DO SO WITHOUT DAMAGING THE FACE OF THE GYPSUM BOARD. 3) FINISH: A) TYPICAL: GA LEVEL 4. B) TEXTURED FINISH: SKIM COAT TO TROWEL PATTERN TO MATCH APPROVED MOCK-UP. C) SURFACES TO RECEIVED FRP: GA LEVEL 1. D) SURFACES TO RECEIVE ADHERED TILE: GA LEVEL 0. 3. EXECUTION A. EXAMINATION 1) PRIOR TO STARTING WORK, INSPECT INSTALLED WORK OF OTHER TRADES AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT WHERE WORK OF THIS SECTION MAY PROPERLY COMMENCE. 2) NOTIFY THE ARCHITECT IN WRITING OF CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK. B. INSTALLATION 1) INSTALL AT WALLS AS INDICATED ON THE DRAWINGS. 2) INSTALL UNITS WITH EDGES FIRMLY SUPPORTED. 3) ATTACH UNITS WITH SCREWS SPACED 6 INCHES ON CENTER ALONG FRAMING. 4) SPACE BOARDS 1/8 TO 3/16 INCH APART. STAGGER BOARD JOINTS WITH THOSE OF ADJACENT ROWS. FILL JOINTS BETWEEN GLASS MESH PANELS WITH BONDING MORTAR, EMBED REINFORCING, COVER OVER WITH BONDING MORTAR AND TROWEL SMOOTH. 3) 2. SCHEDULED; WHITE, UNLESS OTHERWISE INDICATED. B) WALL MOLDINGS: 7/8 OR 1 INCH FLANGE. 2) SEISMIC DESIGN CATEGORIES C, D, E, OR F: A) EXPOSED T SYSTEM; ARMSTRONG "SEISMIC RX," WIDTH AS SCHEDULED; WHITE, UNLESS OTHERWISE INDICATED. B) WALL MOLDINGS: 7/8 OR 1 INCH FLANGE; INCLUDE SEISMIC CLIPS FOR ATTACHMENT OF GRID MEMBERS; ARMSTRONG "BERC2 2" BEAM END RETAINING CLIP," OR APPROVED. B. ACOUSTICAL PANELS: AS SCHEDULED 1) RECYCLED CONTENT: MINIMUM 15 PERCENT CALCULATED (BASED ON SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER) RECYCLED CONTENT. 2) TOXICITY/IEQ: A) FREE FROM ADDED UREA-FORMALDEHYDE. B) INCLUDE MANUFACTURER'S STANDARD ANTI-MICROBIAL TREATMENT: C. METAL PANELS AND TRIM: AS SCHEDULED. D. ACCESSORIES: FURNISH HANGERS, CLIPS, FASTENERS, HANGER WIRE AND OTHER ACCESSORIES AS NECESSARY TO COMPLETE THE WORK. 3. 093000 - TILING 1. 2. 3. GENERAL A. SECTION INCLUDES: 1) CERAMIC FLOOR AND WALL TILE. 2) WATERPROOF MEMBRANES. B. SUBMITTALS: 1) PRODUCT DATA: SUBMIT FOR EACH TYPE OF TILE, MORTAR, GROUT, ADHESIVE, ADDITIVE, ACCESSORY, AND MEMBRANE. 2) SAMPLES: A) TILE: SUBMIT SAMPLES OF EACH TYPE AND COLOR OF TILE. INCLUDE REPRESENTATIVE RANGE OF COLORS AND FINISHES TO BE EXPECTED. B) GROUT: SUBMIT CURED SAMPLES OF EACH GROUT COLOR. C) SHOP DRAWINGS: INDICATE FLOOR PLAN WITH PARTITIONS AND EXISTING CONDITIONS AS APPROPRIATE; SHOW PROPOSED EXPANSION JOINT LOCATIONS, FLOOR DRAINS, FLOOR SINKS, RELATIVE ELEVATIONS, AND PITCHES TO DRAIN. B. 1. 2. EXPANSION JOINTS: 1) PROVIDE FOR EXPANSION JOINTS AT MAXIMUM 24 FEET O.C. 2) MATCH MORTAR JOINT WIDTH, EXCEPT THAT JOINTS SHALL BE NO LESS 092900 - GYPSUM BOARD FIELD PERIMETERS. RAKE JOINTS FREE OF SETTING MORTAR. 1. GENERAL A. SECTION INCLUDES: 1) GYPSUM BOARD AND ACCESSORIES. 2) TROWEL TEXTURED FINISH. 3) PATCHING AND TREATMENT OF EXISTING WALL SURFACES. B. QUALITY ASSURANCE: 1) PERFORM WORK IN ACCORDANCE WITH GA 216, UNLESS SPECIFIED OTHERWISE, OR REQUIRED OTHERWISE TO MEET FIRE RATING REQUIREMENTS. 2) MOCK-UP: APPLY TROWEL TEXTURED FINISH TO MINIMUM 4 FOOT SQUARE PIECE OF GYPSUM BOARD, REPRESENTATIVE OF PROPOSED FINISH WR01. 2. PRODUCTS: A. MANUFACTURER: ONE OF THE FOLLOWING. 1) CERTAINTEED CORP. 2) GEORGIA-PACIFIC GYPSUM, LLC. 3) LAFARGE NORTH AMERICA 4) NATIONAL GYPSUM COMPANY 5) TEMPLE-INLAND INC. 6) USG CORP. B. GYPSUM BOARD: 1) ASTM C1396; 5/8 INCH THICK; TYPE X FOR USE IN FIRE RATED PARTITIONS; CONTRACTOR'S OPTION AT OTHER LOCATIONS. 2) RECYCLED CONTENT: MINIMUM 9 PERCENT CALCULATED (BASED ON SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER) RECYCLED CONTENT. C. WATER RESISTANT BOARD: ASTM C1396; 5/8 INCH THICK. D. INTERIOR GYPSUM TRIM: 1) CONFORM TO GA 216, UNLESS INDICATED OR SPECIFIED OTHERWISE. 2) CONCEALED FLANGE CRIMP-ON OR TAPE-ON TYPE; METAL OR PVC AT INSTALLATION OF TILE: INSTALLERS SHALL FOLLOW INSTRUCTION AS OUTLINED IN THE TCNA HANDBOOK FOR CERAMIC TILE, GLASS AND STONE TILE FOR INSTALLATION. 1) INTERIOR FLOOR APPLICATION - THINSET OVER CONCRETE SUBSTRATES AND CONCRETE WITH WATERPROOF MEMBRANE. A) TCNA SYSTEM: F113. B) INSTALLATION STANDARD: ANSI A108.5. C) SETTING MATERIALS: THINSET MORTAR; 3/32 INCH MINIMUM THICKNESS. D) GROUT: EPOXY. 2) WALL APPLICATION (TILE BASES) - GYPSUM BOARD SUBSTRATE AND GYPSUM BOARD WITH WATERPROOF MEMBRANE: A) TCNA SYSTEM: SIMILAR TO W243. B) INSTALLATION STANDARD: ANSI A108.5. C) SETTING MATERIALS: THINSET MORTAR. D) GROUT: EPOXY. 3) WALL APPLICATION - CEMENTITIOUS TILE BACKING BOARD: A) TCNA SYSTEM: SIMILAR TO W244. B) INSTALLATION STANDARD: ANSI A108.5. C) SETTING MATERIALS: THINSET MORTAR. D) GROUT: EPOXY. D. GROUTING: COMPLY WITH PROVISIONS OF ANSI A108.10. GROUT ALL JOINTS, EXCEPT EXPANSION JOINTS. FLOAT JOINTS TO A SLIGHTLY CONCAVE PROFILE. C. 095410 - SUSPENDED PANEL CEILINGS 1. GENERAL A. SECTION INCLUDES: 1) SUSPENSION SYSTEM 2. QUALITY ASSURANCE: MATERIALS AND INSTALLATION SYSTEM SHALL BE USDA APPROVED FOR FOOD PREPARATION AREAS. PRODUCTS A. FRP PANEL SYSTEMS: COMPOSITE PANEL CONSISTING OF UNIFORM FIBERGLASS GLASS FIBERS EMBEDDED IN ORGANIC RESIN; CLASS C FIRE 1) TYPE: A) EXECUTION A. INSTALL SYSTEM IN ACCORDANCE WITH ASTM C636, IBC 1621.2.5 AND CISCA 1-2 OR CISCA 3_4 AS APPROPRIATE TO THE SEISMIC DESIGN CATEGORY, THE MANUFACTURER'S INSTRUCTIONS, AND AS FOLLOWS. 1) INSTALL ADDITIONAL HANGER WIRES AS NECESSARY TO SUPPORT SUPERIMPOSED LOADS. 2) COORDINATE WITH MECHANICAL, ELECTRICAL, AND FIRE PROTECTION WORK FOR ACCOMMODATION OF PENETRATING ELEMENTS. 3) SET PANELS INTO CEILING GRID. A) BORDER UNITS: WHERE PARTIAL PANELS ARE NECESSARY FOR INSTALLATION AGAINST WALL MOLDINGS, SCRIBE AND CUT PANELS TO FIT THE OPENINGS; INSTALL EACH PANEL WITH CUT EDGE FULLY SUPPORTED BY WALL MOLDING. B) FIELD UNITS: WHERE CUT PANELS ARE NECESSARY TO ACCOMMODATE FRAMING AT LIGHT FIXTURES, DIFFUSERS, AND OTHER INTERRUPTIONS IN THE SUSPENSION SYSTEM MODULE, SCRIBE AND CUT PANELS TO ACCOMMODATE THE FRAMING OR PENETRATION. B. CLEAN-UP: REMOVE FINGERPRINTS, SOIL AND BLEMISHES FROM CEILING MATERIALS. USE CLEANING MATERIALS RECOMMENDED BY THE MANUFACTURER OF THE CEILING MATERIALS. 097200 - WALL COVERING 1. 3. GENERAL A. SECTION INCLUDES: VINYL COMPOSITION TILE FLOORING. B. SUBMITTALS 1) PRODUCT LITERATURE: INCLUDE DESCRIPTIONS OF PHYSICAL CHARACTERISTICS AND INSTALLATION INSTRUCTIONS FOR RESILIENT FLOORING, ADHESIVES, LEVELING COMPOUNDS, AND ACCESSORIES. 2) SAMPLES: 3 FULL SIZE TILES FOR EACH TYPE AND COLOR OF RESILIENT TILE FLOORING MATERIAL. 3) PRODUCT DATA: A) FOR EACH TILE TYPE, INDICATE RECYCLED CONTENT; INDICATE PERCENTAGE OF PRE-CONSUMER AND POST-CONSUMER RECYCLED CONTENT PER UNIT OF PRODUCT; INCLUDE CERTIFICATION TO RFCI FLOORSCORE STANDARD. B) INCLUDE MSDS SHEETS OR OTHER EVIDENCE THAT SHOWS COMPLIANCE TO VOC REQUIREMENTS FOR FILLERS AND ADHESIVES. C. ENVIRONMENTAL REQUIREMENTS 1) MAINTAIN MINIMUM 70 DEGREES F AIR TEMPERATURE AT FLOORING INSTALLATION AREA FOR THREE DAYS PRIOR TO, DURING, AND FOR 24 HOURS AFTER INSTALLATION. 2) STORE FLOORING MATERIALS IN AREA OF APPLICATION; ALLOW MATERIALS TO ACCLIMATE TO ENVIRONMENTAL CONDITIONS PRIOR TO INSTALLATION. D. EXTRA STOCK: DELIVER 10 PERCENT EXTRA STOCK OF EACH COLOR AND PATTERN OF FLOOR MATERIAL REQUIRED FOR PROJECT, FOR MAINTENANCE USE, PROPERLY PACKAGED AND CLEARLY LABELED. PRODUCTS A. RESILIENT TILE FLOORING: AS SCHEDULED; CERTIFIED WITH RFCI FLOORSCORE STANDARD. B. ACCESSORIES 1) SUBFLOOR FILLER: WHITE PREMIX LATEX FILLER, MIXED WITH WATER TO PRODUCE A CEMENTITIOUS PASTE. 2) PRIMER TOXICITY/IEQ: WATER-BASED; CLEAR; OF TYPES AS APPROVED BY RESILIENT FLOORING MANUFACTURER FOR SPECIFIC MATERIAL AND SUBSTRATES ENCOUNTERED. 3) ADHESIVES: A) TYPES RECOMMENDED BY RESILIENT FLOORING MANUFACTURERS FOR SPECIFIC APPLICATION. B) TOXICITY/IEQ: COMPLY WITH APPLICABLE REGULATIONS REGARDING TOXIC AND HAZARDOUS MATERIALS, GS_36 FOR COMMERCIAL ADHESIVE, AND SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. 4) TRANSITION STRIPS: VINYL; PROFILE(S) AS INDICATED; COLOR AS SELECTED BY THE ARCHITECT FROM MANUFACTURER'S STANDARD. 5) ALL OTHER MATERIALS NOT SPECIFICALLY DESCRIBED, BUT REQUIRED FOR A COMPLETE AND PROPER INSTALLATION OF RESILIENT FLOORING, SHALL BE ONLY AS RECOMMENDED BY THE MANUFACTURER OF THE MATERIAL TO WHICH IT IS APPLIED AND SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT. 2. PRODUCTS A. WALL COVERING: TYPES AS SCHEDULED ON THE DRAWINGS; FURNISHED BY THE OWNER. B. ADHESIVES: AS RECOMMENDED BY THE WALL COVERING MANUFACTURER FOR THE APPLICATION. ADHESIVES SHALL MEET THE REQUIREMENTS OF THE SOUTHERN CALIFORNIA SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE 1168. 3. EXECUTION A. EXAMINATION: ENSURE THAT SURFACES TO RECEIVE WALL COVERING HAVE RECEIVED A COAT OF WALL SIZE AS SPECIFIED IN SECTION 099000. B. PREPARATION: REMOVE ELECTRICAL OUTLET AND SWITCH PLATES, MECHANICAL DIFFUSERS, ESCUTCHEONS, REGISTERS, SURFACE HARDWARE, FITTINGS, AND FASTENINGS PRIOR TO STARTING WORK; STORE DURING AND REPLACE AFTER COMPLETION OF WORK. C. INSTALLATION 1) MIX AND APPLY ADHESIVES IN ACCORDANCE WITH THE ADHESIVE MANUFACTURER'S DIRECTIONS FOR THE TYPE OF MATERIAL BEING APPLIED. 2) INSTALL WALL COVERING SECURE, SMOOTH, CLEAN, AND WITHOUT WRINKLES, GAPS OR OVERLAPS. 3) EXTEND WALL COVERING CONTINUOUSLY BEHIND ITEMS WHICH ARE CLOSE TO BUT NOT TOUCHING WALLS. 4) PROVIDE DOUBLE-CUT SEAMS ON NONMATCH PATTERNS; BUTT SEAMS ON MATCH PATTERNS. 5) INSTALL WALL COVERING ORIENTED VERTICALLY, UNLESS OTHERWISE INDICATED. 6) CORNER SEAMS: MAKE NO SEAMS WITHIN 6 INCHES OF AN INSIDE OR OUTSIDE CORNER, EXCEPT WHERE A COLOR OR PATTERN CHANGE IS INDICATED. LAP WALL COVERINGS AT INSIDE CORNER SEAMS TO PREVENT SUBSTRATE SHOW THROUGH. 1. 2. PREPARATION: INSTALL SUBFLOOR FILLER TO FILL LOW SPOTS, CRACKS, CONSTRUCTION JOINTS, HOLES AND OTHER DEFECTS, AND AS REQUIRED TO ADJUST LEVEL TO MEET ADJACENT FINISHES. FEATHER TO MAXIMUM SLOPE OF 1/8 INCH IN 3 FEET; FLOAT TO SMOOTH, FLAT, HARD SURFACE. PROHIBIT TRAFFIC OVER FILLER. C. FLOORING INSTALLATION 1) MIX TILE TO ENSURE SHADE VARIATIONS DO NOT OCCUR WITHIN ANY ONE AREA. 2) UNLESS INDICATED OTHERWISE, INSTALL FLOORING WITH JOINTS AND SEAMS PARALLEL TO BUILDING LINES. INSTALL WITH MINIMUM TILE WIDTH 1/2 FULL SIZE AT ROOM OR AREA PERIMETER. 3) ARRANGE TO SQUARE GRID PATTERN WITH ALL JOINTS ALIGNED. COLOR: P199 "PEBBLED SURFACE"; "BRIGHT WHITE." ADHESIVE: "C-551 MARLITE FRP ADHESIVE," UNLESS OTHERWISE RECOMMENDED BY THE PANEL MANUFACTURER FOR THE SUBSTRATE INDICATED; VOC MAXIMUM 50 G/L. C. SEALANT: MANUFACTURER'S STANDARD SILICONE SEALANT; WHITE. D. TRIM MOLDINGS: MANUFACTURER'S STANDARD PVC; COLOR TO MATCH PANELS. 1) EDGE (J): M370. 2) DIVISION (H): M365 3) INSIDE CORNER: M350. 4) OUTSIDE CORNER: M360. 2) 3. 3. EXECUTION A. EXAMINATION: ENSURE THAT SURFACES TO RECEIVE WALL COVERING HAVE RECEIVED A COAT OF WALL SIZE AS SPECIFIED IN SECTION 099000. B. INSTALLATION 1) COORDINATE WITH OTHER TRADES TO ACCOMMODATE ADJACENT FINISHES. 2) DRY FIT SHEETS INTO PLACE BEFORE APPLYING ADHESIVE. 3) CUT HOLES ACCURATELY TO CONFORM TO THE PENETRATION, AND OVERSIZED BY 1/16" ALL AROUND. 4) CLEAN SUBSTRATE AND PANEL SURFACES. 5) APPLY ADHESIVE IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED APPLICATION INSTRUCTIONS. 6) TROWEL APPLY ADHESIVE CONTINUOUSLY OVER SUBSTRATE. BOND EACH SHEET TO THE SUBSTRATE BY PROGRESSING FROM ONE SIDE TO THE OTHER TO EXPEL ALL AIR. APPLY PRESSURE UNIFORMLY TO THE FACE OF THE SHEET BY USING A WIDE HARD RUBBER ROLLER. 7) ALLOW 1/16 INCH EXPANSION SPACE BETWEEN PANELS AND AT ALL SURROUNDING CONSTRUCTION. C. REMOVE ADHESIVE FROM FACE OF PANELS USING SOLVENT RECOMMENDED BY ADHESIVE MANUFACTURER. 097736 - FIBERGLASS REINFORCED PLASTIC PANEL WALL COVERINGS 1. GENERAL A. SECTION INCLUDES: FIBERGLASS REINFORCED PLASTIC (FRP) WALL COVERING PANEL SYSTEM. B. SUBMITTALS 1) PRODUCT LITERATURE. 2) SAMPLES: A) EACH TYPE OF JOINT/TRIM PROFILE; MINIMUM 12 INCHES LONG; B) PROPOSED PANEL; MINIMUM 12 X 12 INCHES EXECUTION A. PREPARATION : COORDINATE INSTALLATION WITH THE INSTALLERS OF ADJACENT AND INTEGRAL CONSTRUCTION TO ALLOW FOR INSTALLATION OF FRP PANELS PRIOR TO THE INSTALLATION OF ESCUTCHEONS, COVER PLATES, LOUVER FLANGES, AND OTHER COMPONENTS TO BE INSTALLED OVER OR THROUGH FRP PANELS. B. ADHESIVE WALL PANEL INSTALLATION 1) ACCURATELY CUT AND FIT PANELS AROUND OBSTRUCTIONS; SCRIBE FIT AT EDGES. 2) DO NOT INSTALL PANELS WITH EDGE OR SURFACE DAMAGE. REPLACE WITH NEW UNDAMAGED MATERIAL, ALL PANELS WHICH BECOME CHIPPED OR DAMAGED PRIOR TO FINAL ACCEPTANCE. 3) PROVIDE J MOLDING AT ALL EXPOSED EDGES. PROVIDE H MOLDING AT ALL VERTICAL BUTT JOINTS. H MOLDINGS SHALL NOT BE RUN BEHIND BASE FINISH MATERIAL. PROVIDE TRIM MOLDINGS AT INSIDE AND OUTSIDE CORNERS. 4) SEAL ALL JOINTS BETWEEN PANELS AND MOLDINGS, AND BETWEEN FRP SYSTEM AND ADJACENT CONSTRUCTION. C. CLEAN-UP: REMOVE SOIL AND BLEMISHES FROM WALL MATERIALS. 099000 - PAINTING 1. GENERAL A. SECTION INCLUDES: SITE APPLIED INTERIOR PAINT COATINGS. B. APPLICATOR QUALIFICATIONS: COMPANY SPECIALIZING IN COMMERCIAL PAINTING AND FINISHING WITH A MINIMUM OF THREE YEARS DOCUMENTED EXPERIENCE. C. MAINTENANCE STOCK: FURNISH OVERAGE OF PAINT MATERIALS EQUAL TO 10 PERCENT MINIMUM OF QUANTITY OF EACH FINISH PAINT SYSTEM COMPONENT, COLOR AND SHEEN REQUIRED FOR THE WORK, BUT FURNISH NOT MORE THAN ONE FULL ONE GALLON CANS, NOR LESS THAN TWO FULL ONE PINT CANS, OF EACH TYPE. OVERRUNS IN EXCESS OF ONE GALLON MAY BE FURNISHED TO THE OWNER AT THE CONTRACTOR'S OPTION. OVERAGE SHALL BE TAKEN FROM THE BATCH MIX FURNISHED FOR THE WORK. OVERAGE SHALL BE FURNISHED IN COMPLETELY FILLED, PROPERLY LABELED, SEALED CANS. 2. PRODUCTS A. INTERIOR LATEX WALL AND CEILING PAINT SYSTEM; COLOR MATCH AS SCHEDULED. 1) MANUFACTURER: BENJAMIN MOORE PAINT COMPANY 2) GYPSUM BOARD PRIMER: "NATURA INTERIOR WATERBORNE PAINT PRIMER 511"; ZERO VOC 3) METAL PRIMER (DTM): "IRONCLAD LATEX LOW LUSTRE METAL & WOOD ENAMEL C363"; MAXIMUM VOC CONTENT 150 G/L. 4) WOOD PRIMER: "IRONCLAD LATEX LOW LUSTRE METAL & WOOD ENAMEL C363"; MAXIMUM VOC CONTENT 150 G/L. 5) FINISH: A) EGGSHELL: "NATURA INTERIOR WATERBORNE PAINT EGGSHELL 513"; ZERO VOC B) SEMI-GLOSS: "NATURA INTERIOR WATERBORNE PAINT SEMI-GLOSS 514"; ZERO VOC B. INTERIOR TRANSPARENT FINISH SYSTEM. 1) STAIN: AS SCHEDULED. 2) TRANSPARENT FINISH: MINWAX "POLYCRYLIC PROTECTIVE FINISH," OR APPROVED; SATIN SHEEN UNLESS OTHERWISE INDICATED. C. ACRYLIC WALL SIZE: BENJAMIN MOORE PAINT COMPANY "MOORE'S GENERAL A. SECTION INCLUDES: STAINLESS STEEL SHEET ADHERED DIRECTLY TO THE WALL. B. PRODUCT LITERATURE: ADHESIVE. C. SUBMITTALS: AS NECESSARY TO COORDINATE FABRICATION WITH FIELD DIMENSIONS. D. ENVIRONMENTAL CONDITIONS 1) ACCLIMATIZE TO AMBIENT TEMPERATURE (~70 DEGREES F) BEFORE INSTALLATION. 2) MAINTAIN ADEQUATE VENTILATION AND CONDITIONS TO PREVENT COMBUSTION OF ADHESIVE FUMES. PRODUCTS A. STAINLESS STEEL SHEET PANELS: FURNISHED BY THE OWNER. B. WATER RESISTANT CONTACT BOND ADHESIVE; MAXIMUM VOC 250 G/L. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM ACCEPTABLE OPTION (SUBJECT TO COMPLIANCE WITH CONTRACT DOCUMENT REQUIREMENTS AND ARCHITECT'S APPROVAL OF COLOR AND CONFORMANCE TO DESIGN INTENT.): CRANE B. 097243 STAINLESS STEEL WALL COVERING EXECUTION A. MOISTURE TESTING OF CONCRETE SLABS: PERFORM ANHYDROUS CALCIUM CHLORIDE TESTS IN ACCORDANCE WITH ASTM F1869 TO DETERMINE THE VAPOR EMISSION RATE FROM THE CONCRETE SLAB. NOTIFY THE ARCHITECT IF TESTS RESULTS SHOW A VAPOR EMISSION RATE B. GENERAL A. SECTION INCLUDES: INSTALLATION OF OWNER FURNISHED WALL COVERINGS. B. SUBMITTALS: SUBMIT PRODUCT DATA FOR PROPOSED ADHESIVES AND ACCESSORIES. INCLUDE MSDS SHEETS OR OTHER EVIDENCE THAT SHOWS COMPLIANCE TO VOC REQUIREMENTS FOR ADHESIVES. C. QUALITY CONTROL: WALL COVERING INSTALLER SHALL HAVE MINIMUM OF 3 YEARS EXPERIENCE IN WALL COVERING INSTALLATIONS OF SIMILAR AND SCOPE. D. DELIVERY, STORAGE, AND HANDLING: STORE WALL COVERING MATERIALS FLAT, NOT UPRIGHT, IN A DRY AREA. MAINTAIN TEMPERATURE OF STORAGE AREA AT A MINIMUM OF 45 DEGREES F., UNLESS A HIGHER TEMPERATURE IS RECOMMENDED BY WALL COVERING MANUFACTURER. E. ENVIRONMENTAL CONDITIONS 1) TEMPERATURE: A) DO NO WALL COVERING WORK UNTIL SURFACES AND MATERIALS B) RECOMMENDED BY WALL COVERING MANUFACTURER, FOR 3 DAYS BEFORE WORK BEGINS. B) MAINTAIN MINIMUM OR ABOVE TEMPERATURES DURING THE ENTIRE INSTALLING TIME AND UNTIL ADHESIVES HAVE FULLY DRIED OR CURED. 2) LIGHTING: DURING INSTALLATION, MAINTAIN MINIMUM LIGHTING LEVEL OF 15 FOOT-CANDLES ON THE SURFACES TO RECEIVE WALL COVERING. USE TEMPORARY LIGHTING, IF NECESSARY, TO ATTAIN SPECIFIED LEVEL. SECTION 096519 - RESILIENT TILE FLOORING PRODUCTS A. TILE: AS SCHEDULED ON THE DRAWINGS. B. ACCESSORY MATERIALS: AS FOLLOWS, UNLESS OTHERWISE RECOMMENDED BY THE TILE MANUFACTURER. 1) TILE WATERPROOFING MEMBRANE: ONE OF THE FOLLOWING. A) NOBLE COMPANY "NOBLESEAL TS." B) BOSTIK "HYDROMENT ULTRA-SET." C) MAPEI AMERICAS. "MAPELASTIC SMART.." D) LATICRETE HYDROBAN 2) THINSET MORTAR: IN ACCORDANCE WITH ANSI A118.4; PORTLAND CEMENT WITH 100 PERCENT ACRYLIC LATEX ADDITIVE A) LATICRETE 254 PLATINUM 3) EPOXY GROUT: ONE OF THE FOLLOWING; COLOR MATCH AS SCHEDULED ON THE DRAWINGS. A) MAPEI AMERICAS "KERAPOXY." B) BOSTIK "HYDROMENT COLOR-POXY." C) LATICRETE INTERNATIONAL INC. "SPCTRALOCK 2000 IG GROUT." EXECUTION A. SLAB LEVELING: 1) PRIOR TO INSTALLATION OF THINSET FLOOR TILE, WHERE LOCAL IRREGULARITIES IN THE SUBSTRATE SURFACE WOULD CAUSE PUDDLING, PREVENT LEVEL INSTALLATION OF THE TILE, OR INTERRUPT DRAINAGE PATTERNS, THE SUBSTRATE SHALL BE ADJUSTED AS NECESSARY. USE THINSET MORTAR OR OTHER FILLER FOR SLAB LEVELING. 2) WHERE PITCHES TO DRAIN ARE INDICATED, SLOPE FLOORING MINIMUM PRODUCTS A. SUSPENSION SYSTEM: 1) SEISMIC DESIGN CATEGORIES A OR B: C. A) 1) GENERAL A. SECTION INCLUDES: GLASS MESH REINFORCED CEMENT BOARD SUBSTRATE FOR TILE. B. SUBMITTALS: PRODUCT DATA. PRODUCTS A. BOARD MATERIAL: 1/2 INCH NOMINAL THICKNESS AGGREGATED PORTLAND CEMENT PANEL, REINFORCED WITH GLASS FIBER MESH; ONE OF THE FOLLOWING. 1) CUSTOM BUILDING PRODUCTS (SEAL BEACH CA; 800-272-8786) "WONDERBOARD." 2) FINPAN (HAMILTON OH; 800_833_6444) "UTIL-A-CRETE." 3) USG CORPORATION (CHICAGO, IL; 312-436-4000) "DUROCK." 4) NATIONAL GYPSUM COMPANY (CHARLOTTE NC; 800_628_4662) "PERMABASE." B. TAPE FOR GLASS MESH BOARD: OPEN WEAVE GLASS MESH JOINT TAPE, SELF-ADHESIVE; 2-1/2 INCHES WIDE. C. FASTENERS: AS RECOMMENDED BY THE BACKER BOARD MANUFACTURER; THREAD FORMING SELF-DRILLING WAFER HEAD SCREWS; POLYMER COATED OR ZINC PLATED; USG "DUROCK SCREWS," "ROCK-ON," OR APPROVED. D. BONDING MORTAR: THINSET MORTAR, AS SPECIFIED IN SECTION 093000. EXECUTION A. INSTALLATION STANDARD: PERFORM WORK IN ACCORDANCE WITH GYPSUM ASSOCIATION GA-216. B. INSTALL WATER RESISTANT BOARD WHERE INDICATED AS SUBSTRATE FOR TILE IN TOILET ROOMS. C. SCREW FASTEN BOARD TO FRAMING. UNLESS OTHERWISE INDICATED, INSTALL WITH PATTERN GRAIN ALTERNATING WITH ADJACENT UNIT TO PRODUCE BASKET WEAVE PATTERN (WHERE APPROPRIATE). 4) TERMINATE RESILIENT FLOORING AT CENTERLINE OF DOOR AT DOOR OPENINGS WHERE ADJACENT FLOOR FINISH IS DISSIMILAR, AND WHERE NO THRESHOLD IS INDICATED. 5) INSTALL EDGE STRIPS AT UNPROTECTED OR EXPOSED EDGES WHERE FLOORING TERMINATES. PANEL CEILING. METAL PANEL CEILING AND TRIM B. QUALITY ASSURANCE: PERFORM NEW WORK AS NECESSARY TO MAINTAIN COMPLIANCE WITH IBC 1621.2.5, SEISMIC DESIGN CATEGORY D, AND THE REQUIREMENTS OF THE JURISDICTIONAL CODE AUTHORITIES. 2) D. 092813 - CEMENTITIOUS BACKING BOARDS A) PROPRIETARY COMPENSATING CHANNEL SYSTEM, UTILIZING TSN "VERTICLIP SLD," FIRE TRAK INC. "POSI KLIPS," OR SIMILAR SYSTEM AT CONTRACTOR'S OPTION. B. PROPRIETARY CEILING SUSPENSION SYSTEM: 1) MANUFACTURER: A) BASIS OF DESIGN: CHICAGO METALLIC (LOS ANGELES CA; 800-323-7164). B) ACCEPTABLE OPTIONS (SUBJECT TO COMPLIANCE WITH CONTRACT DOCUMENT REQUIREMENTS AND ARCHITECT'S APPROVAL OF CONFORMANCE TO DESIGN INTENT.): (1) USG INTERIORS, INC. (CHICAGO, IL; 800-874-4968). (2) ARMSTRONG (800_207_2321). 2) SUSPENSION SYSTEM: SIMILAR TO SYSTEM 650, OR 670; ASTM C635 HEAVY DUTY CLASSIFICATION. C. ACCESSORIES: 1) SCREWS: SELF DRILLING; LOW PROFILE HEAD; GALVANIZED. 2) CONCRETE ANCHORS: POWERS FASTENERS "POWDER ACTUATED FASTENERS," ITW RAMSET "POWDER FASTENERS," HILTI "POWDER ACTUATED NAILS," OR APPROVED; TYPES AS APPROPRIATE TO THE WORK. 3) HANGER WIRE: ASTM A641; CLASS 1 ZINC COATING; SOFT TEMPER; PRESTRETCHED; 12 GAGE. 4) RESILIENT CHANNELS: USG "RC-1," OR APPROVED. 5) BACKING: DIETRICH INDUSTRIES (RENTON WA; 425_251_1497) "DANBACK FLEXIBLE WOOD BACKING PLATE"; UNTREATED; LENGTH AS APPROPRIATE TO STUD SPACING. 6) OTHER FRAMING MATERIALS: IN ACCORDANCE WITH ASTM C754. CONTRACTOR'S OPTION. JOINT COMPOUND, TAPE, AND FINISHING COMPOUND: ASTM C475; PAPER TAPE, TYPICAL; SELF-ADHESIVE FIBERGLASS MESH TAPE FOR USE AT SURFACES TO RECEIVE ADHERED TILE. F. SCREWS: ASTM C1002. E. 3. EXECUTION A. PREPARATION: 1) MOISTURE CHECK: CHECK FOR EXCESS MOISTURE USING AN ELECTRONIC MOISTURE METER. DO NOT PAINT MATERIALS WITH EXCESS MOISTURE LEVELS WHICH WOULD IMPAIR THE BONDING OF FINISH COATINGS. 2) HARDWARE AND MISCELLANEOUS ITEMS: A) CAREFULLY REMOVE ELECTRICAL OUTLET AND SWITCH PLATES, MECHANICAL DIFFUSERS, ESCUTCHEONS, SURFACE HARDWARE, FITTINGS AND FASTENINGS PRIOR TO STARTING WORK.CAREFULLY STORE, B) CLEAN AND REPLACE THESE ITEMS UPON COMPLETION OF WORK IN EACH AREA. 3) REMOVE DIRT, DUST, GREASE, OIL, MOISTURE, AND OTHER CONTAMINANTS WHICH WILL IMPAIR THE PROPER ADHESION OF THE FINISH. 4) MASK ADJACENT SURFACES. B. APPLICATION REQUIREMENTS 1) UNLESS SPECIFIED OR INDICATED OTHERWISE, FOLLOW PAINT MANUFACTURER'S LABEL DIRECTIONS FOR GENERAL APPLICATION PROCEDURES AND COVERAGE RATES. 2) OPAQUE FINISHES: A) APPLY NUMBER OF COATS SCHEDULED, EXCEPT THAT ADDITIONAL FINISH COATS SHALL BE APPLIED AS NECESSARY FOR COMPLETE HIDING OF SUBSTRATE COLORS. B) APPLY PRIMER COATS UNTINTED. WHERE MORE THAN ONE COAT OF PAINT IS REQUIRED, TINT EACH SUCCEEDING COAT UP TO THE FINAL COAT SIMILAR IN TINT, BUT SLIGHTLY LIGHTER IN VALUE (SHADE). C) SAND LIGHTLY BETWEEN COATS IF NECESSARY TO ACHIEVE REQUIRED FINISH; SAND BETWEEN ALL COATS APPLIED TO WOOD SUBSTRATES. D) ROLLERS FOR APPLICATION AND BACKROLLING OF LATEX PAINTS SHALL HAVE A NAP OF 3/8 INCH OR LESS. E) WHERE ROLLER TEXTURE IS SCHEDULED FOR APPLICATION TO GYPSUM BOARD SURFACES, FINISH COATS MAY BE ROLLER-APPLIED, OR SPRAY APPLIED AND BACKROLLED AT CONTRACTOR'S OPTION. A R 4 0 4 S. C Wells H I S t ., T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. PROJECT NUMBER: 16-059 4. OPTION, PROPRIETARY OR STEEL BACKING PLATES MAY BE SUBSTITUTED FOR WOOD BLOCKING INDICATED ON DRAWINGS. 2) UNLESS INDICATED OTHERWISE, STEEL BACKING SHALL CONSIST OF MINIMUM 4 INCH WIDE 16 GAGE STEEL PLATE SCREWED RIGIDLY TO THE STUDS. C. CEILING FRAMING 1) CEILING FRAMING SHALL CONSIST OF STUD AND RUNNER FRAMING OR SUSPENDED FRAMING, UNLESS INDICATED OR SPECIFIED OTHERWISE. 2) SUSPENDED FRAMING SHALL BE SUSPENDED FROM OVERHEAD STRUCTURAL ELEMENTS ONLY. 3) STUD AND RUNNER FRAMING: A) SECURE RUNNERS TO STRUCTURE ABOVE WITH FASTENERS AT A MAXIMUM OF 24 INCHES O.C.. SIZE FASTENERS AND USE REINFORCEMENTS AS NECESSARY TO SUPPORT THE DEAD LOADS. B) SPACE STUDS AT 16 INCHES O.C. AT HORIZONTAL LOCATIONS. 4) LIGHTGAGE SUSPENDED FRAMING: A) INSTALL IN ACCORDANCE WITH ASTM C754, UNLESS INDICATED OR SPECIFIED OTHERWISE. B) SPACE CARRYING CHANNELS 4 FEET O.C. WITH SPLICES LAPPED MINIMUM 12 INCHES. C) SUPPORT COLD ROLLED CARRYING CHANNELS WITH HANGER WIRES SPACED AT 4 FEET O.C. LOOP HANGER WIRE AROUND SUPPORT ELEMENT AND TIGHTLY WRAP AROUND VERTICAL WIRE 3 TIMES; CUT OFF NEATLY. D) SPACE FURRING CHANNELS 16" O.C. WITH SPLICES LAPPED 12", MINIMUM AND TIED; CLIP OR SADDLE TIE TO RUNNER CHANNELS WITH 16-GAGE TIE WIRE. E) WHERE OVERHEAD OBSTRUCTIONS PREVENT THE REGULAR SPACING OF HANGERS, PROVIDE SECONDARY CARRYING MEMBERS FOR INDIRECT SUPPORT OF THE SUSPENSION SYSTEM, OR REINFORCE THE NEAREST ADJACENT HANGERS AND RELATED FRAMING COMPONENTS AS NECESSARY TO SPAN THE REQUIRED DISTANCE. 5) PROPRIETARY SUSPENDED FRAMING: PER MANUFACTURER'S RECOMMENDATIONS. 6) STABILIZE SUSPENDED CEILING FRAMING AGAINST LATERAL MOVEMENT BY MEANS OF DIAGONAL BRACING. 7) INSTALL SUPPLEMENTARY HANGER WIRES FOR SUPPORT OF CEILING MOUNTED EQUIPMENT. D. TOLERANCES 1) SURFACE PLANE VARIATION: 1/8 INCH IN 10 FEET. 2) POSITION: WITHIN 1/4 INCH OF REQUIRED LOCATIONS. EXECUTION A. INSTALL INSULATING GLASS UNITS IN EXTERIOR STOREFRONTS AND ALUMINUM/GLASS ENTRANCE DOORS. B. INSTALL CLEAR TEMPERED GLASS IN INTERIOR FRAMES AS INDICATED. C. SETTING BLOCKS: PLACE SETTING BLOCKS IN FRAMES FOR SUPPORT OF GLASS. PLACE AT QUARTER POINTS UNLESS APPROVED OTHERWISE. D. SET GLASS TIGHTLY IN POSITION WITH PROPER CLEARANCES IN ACCORDANCE WITH THE FRAME MANUFACTURER'S REQUIREMENTS. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 3. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 SHEET TITLE ARCHITECTURAL SPECIFICATIONS SHEET NUMBER AS1.3 APPROVED. SIGNS: 6 X 9 INCHES; HIGH IMPACT STYRENE; WHITE ON BLUE GRAPHICS; GRADE II BRAILLE; FONT MANUFACTURER'S STANDARD; MINIMUM 5/8 INCH HIGH TEXT AS INDICATED. D. ILLUMINATED SIGNAGE: PROVIDED BY THE OWNER. E. FABRICATION: SIGNS SHALL BE FREE OF ROUGH EDGES, IRREGULAR SURFACES, NON UNIFORM FINISHES, AND SIMILAR IMPERFECTIONS. 2) D. E. F. G. H. 099734 - APPLIED CONCRETE FINISHING SYSTEMS 1. GENERAL A. SECTION INCLUDES: STAIN AND SEALER FOR INTERIOR SLAB SURFACES. B. QUALITY ASSURANCE C. INSTALLER QUALIFICATIONS: FLOORCARE USA PLEASE CONTACT: BRIAN BRUNNER FLOORCARE USA, INC. 2236 W. BLUEMOUND ROAD UNIT E. WAUKESHA, WI 53186 OFFICE: 262-786-0770 X111 FAX: 262-786-5284 WWW.FLOORCARE-USA.COM D. PROJECT CONDITIONS 1) MAINTAIN AN AMBIENT TEMPERATURE BETWEEN 50 DEG F AND 90 DEG F DURING APPLICATION AND FOR AT LEAST 48 HOURS AFTER APPLICATION. 2) PROVIDE ADEQUATE VENTILATION. 2. PRODUCTS A. STAIN AND SEALER SYSTEM: 1) MANUFACTURER: L.M. SCOFIELD COMPANY (LOS ANGELES, CA; 323-720-3000)(DOUGLASVILLE, GA; 770-920-6000) 2) STAIN: A) STAIN: ONLY AS DIRECTED BY PSW B) COLOR: COLORS, PROPORTIONS, AND TECHNIQUES AS DIRECTED BY THE OWNER'S REPRESENTATIVE, TO MATCH OWNER'S SAMPLE 3) SEALER: SELECTSEAL-W; WATERBORNE LOW VOC CLEAR ACRYLIC POLYURETHANE SEALER; SEMI-GLOSS SHEEN. 3. EXECUTION A. EXAMINATION: PRIOR TO APPLICATION OF EACH PRODUCT, VERIFY THAT SURFACES TO BE COATED ARE WITHIN HUMIDITY AND PH RANGES REQUIRED BY THE MANUFACTURER OF EACH SYSTEM. B. PREPARATION 1) CLEAN SURFACES TO RECEIVE STAIN/SEALER AND TOPCOAT, USING MANUFACTURER'S RECOMMENDED CLEANING COMPOUNDS, AND IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 2) MASK OR OTHERWISE PROTECT ADJACENT SURFACES. C. APPLICATION 1) STAIN AND SEALER SYSTEM: A) STAIN: (1) APPLY TO EXPOSED CONCRETE FLOOR SURFACES, AS SCHEDULED. (2) SPRAY APPLY; MAINTAIN A WET EDGE. (3) MULTIPLE COATS (IF REQUIRED): UNLESS OTHERWISE DIRECTED, ALLOW EACH APPLICATION TO DRY FOR A MINIMUM 3. EXECUTION: A. GRAPHICS SHALL BE MOUNTED LEVEL AND PLUMB AND IN ACCURATE ALIGNMENT. B. PLAQUES: 1) CLEAN SURFACES AS NECESSARY TO ACCEPT MOUNTING TAPE. 2) USE DOUBLE STICK TAPE FOR MOUNTING UNLESS APPROVED OTHERWISE. C. DECALS: ADHERE TO SUBSTRATE FREE OF BUBBLES. D. COORDINATE WITH OWNERS VENDOR FOR INSTALLATION OF OWNER FURNISHED SIGNAGE. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. C Wells H I S t ., T Suite E 300 C T S Chicago, + IL P L A 60607 N P: N 312 E 955 R ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 SEALER: AFTER STAIN HAS DRIED THOROUGHLY, ROLL APPLY SEALER IN ACCORDANCE WITH THE MANUFACTURER'S APPLICATION INSTRUCTIONS. APPLY TWO COATS UNLESS OTHERWISE RECOMMENDED OR REQUIRED TO MATCH APPROVED MOCK-UP. D. PROTECTION: PROTECT FLOOR FROM TRAFFIC FOR AT LEAST 48 HOURS AFTER FINAL APPLICATION OF SEALER. B) DIVISION 10 - SPECIALTIES 101400 - SIGNAGE 1. 2. GENERAL: A. SECTION INCLUDES: 1) INSTALLATION OF SIGNAGE FURNISHED BY THE OWNER. 2) CODE REQUIRED, INFORMATIONAL AND DIRECTIONAL AT LOCATIONS INDICATED ON THE DRAWINGS. B. REGULATORY REQUIREMENTS: SIGNAGE SHALL CONFORM TO THE REQUIREMENTS OF THE JURISDICTIONAL CODE AUTHORITIES. PRODUCTS A. GENERAL: FURNISH SIGNAGE SIMILAR TO DETAILS. FOR CUSTOM SIGNAGE, FONT SHALL BE OPTIMA, OR APPROVED. B. DECALS: 1) TYPICAL: PROVIDED BY OWNER. 2) THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED: PROVIDED UNDER SECTION 087103. C. HANDICAPPED TOILET ROOM SIGNS: 1) MANUFACTURER: SS GRAPHICS INC (WYANDOTTE MI; 800-513-1695), OR S 0334 PROJECT NUMBER: 16-059 GYPSUM BOARD - LATEX SYSTEM: SYSTEM: THREE COATS - FIRST COAT LATEX PRIMER SEALER (UNTINTED), SECOND AND THIRD COAT LATEX PAINT (OMIT THIRD COAT AT PREVIOUSLY PAINTED WALLS SUBJECT TO APPROVAL BY THE ARCHITECT.) 2) SHEEN: ROLLER TEXTURE; SHEEN AS SCHEDULED. 3) APPLICATION: A) EXCEPT AS OTHERWISE INDICATED, USE ON ALL EXPOSED GYPSUM BOARD SURFACES INDICATED TO BE PAINTED OR REPAINTED. B) PROVIDE PRIME COAT ONLY BEHIND PERMANENTLY MOUNTED MECHANICALLY ANCHORED ITEMS C) DO NOT APPLY PRIMER OR PAINT COATINGS TO SURFACES TO RECEIVE WALL COVERING. GYPSUM BOARD - SURFACES TO RECEIVE WALL COVERING: APPLY ONE COAT OF ACRYLIC WALL SIZE. FERROUS METAL AND GALVANIZED - ACRYLIC SYSTEM: 1) SYSTEM: THREE COATS; FIRST COAT ACRYLIC DTM PRIMER (OMIT AT SHOP PRIMED ITEMS); SECOND AND THIRD COATS LATEX FINISH. THE PRIMER MAY BE DELETED AT FACTORY PRIMED SURFACES, EXCEPT AS NECESSARY TO RECOAT DAMAGED OR ABRADED PREPRIMED SURFACES. 2) SHEEN: SEMI-GLOSS. 3) APPLICATION: INTERIOR FERROUS METAL SURFACES SCHEDULED FOR PAINT FINISH INCLUDING INTERIOR HOLLOW METAL DOOR AND FRAME AND ELECTRICAL PANELS. WOOD - ACRYLIC SYSTEM: 1) SYSTEM: PROVIDE THREE COATS; FIRST COAT WOOD PRIMER; SECOND AND THIRD COATS LATEX FINISH. 2) APPLICATION: INTERIOR WOOD TRIM AND PANEL SURFACES SCHEDULED FOR PAINT FINISH. WOOD - ACRYLIC SYSTEM: 1) SYSTEM: UNLESS OTHERWISE SCHEDULED OR DIRECTED, PROVIDE THREE COATS; FIRST COAT STAIN, SECOND AND THIRD COATES CLEAR PROTECTIVE FINISH. 2) APPLICATION: INTERIOR WOOD TRIM AND PANEL SURFACES SCHEDULED FOR STAIN FINISH. CLEANUP 1) AS THE WORK PROCEEDS AND ON COMPLETION OF THE WORK, PROMPTLY REMOVE ALL PRIMERS, PAINTS AND FINISHES WHERE SPILLED, SPLASHED OR SPLATTERED IN A MANNER NOT TO DAMAGE THE SURFACE FROM WHICH IT IS REMOVED. 2) REMOVE MASKING. 1) BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 C. SHEET TITLE ARCHITECTURAL SPECIFICATIONS SHEET NUMBER AS1.4 4-#12 SELF TAPPING SCREWS ON EACH SIDE - RTU TO CURB GENERAL STRUCTURAL NOTES 1. 2. 3. 4. THIS DRAWING SET IS TO BE VIEWED AS A WHOLE AND COORDINATED WITH ARCHITECTURAL, MECHANICAL, AND OTHER DISCIPLINES. ALL WORK PERTAINING TO A SPECIFIC CONTRACTOR MAY OR MAY NOT BE SHOWN ON SPECIFIC DRAWING SECTIONS. IT IS EACH SUBCONTRACTOR'S RESPONSIBILITY TO PREPARE HIS BID FROM A COMPLETE SET OF PLANS. THE CONTRACTOR SHALL FOLLOW WRITTEN DIMENSIONS ONLY. DO NOT SCALE DRAWINGS. DIMENSIONS NOT SHOWN ON PLAN TO BE COORDINATED WITH ARCHITECTURAL PLANS. 6. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER IMMEDIATELY OF ANY DISCREPANCIES BETWEEN CONSTRUCTION DOCUMENTS AND ACTUAL FIELD CONDITIONS. 7. SEE ARCHITECTURAL PLANS FOR ADDITIONAL DETAILS AND INFORMATION. 8. ALL ELEVATIONS GIVEN ARE REFERENCED TO FINISHED FLOOR ELEVATIONS AT 100'-0", UNLESS SHOWN AS USGS ELEVATIONS. A-A CURB PER MECH SHAPED PRESSURE TREATED BLKG UNDER MECH CURB "A" 3/8" BOLT w/ WASHERS AND LOCK NUTS (MIN 8 TOTAL) LOAD 2" MAX 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM BLKG BELOW IF CURB LANDS ON RIDGE COPE TOP LEG OF ANGLE A L4x4x1/4" UNDER RTU CURB TYP - PROVIDE JOIST STRUT AS REQD - PER TYP JOIST LOAD STRUT DETAIL HANGING LOAD BM OR JOIST B OUTLINE OF RTU CURB S1.0 H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 E 955 R S 0334 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. NOTE:: DETAIL APPLIES TO ALL CONCENTRATED LOADS WHICH EXCEED 100# AND ARE LOCATED MORE THAN 3" OFF PANEL POINTS (TOP OR BOTTOM CHORDS) B-B 10. ALL HOLES THROUGH CONSTRUCTION SHALL BE CORE DRILLED OR SAWCUT. EA END 1/4 STEEL JOIST NEW L2x2x1/4" FROM FRAME TO BOTTOM CHORD JOIST PANEL POINT (SEE TYPICAL JOIST LOAD STRUT DETAIL) C Wells ILLINOIS DESIGN FIRM # 184.006688 "A" 3/16 B A R 4 0 4 S. WHERE GENERAL NOTES OR TYPICAL DETAILS CONTRADICT INFORMATION PROVIDED IN BUILDING SECTIONS, THE BUILDING SECTIONS TAKE PRECEDENCE. 11. WHERE INFORMATION PROVIDED IN THESE STRUCTURAL DRAWINGS CONTRADICTS INFORMATION PROVIDED IN BUILDING SPECIFICATIONS, THE SPECIFICATIONS SHALL TAKE PRECEDENCE. WHERE DIM "A" IS EQUAL TO OR GREATER THAN 3" FIELD INSTALL L2x2x1/4" EA SIDE OF JOIST AS SHOWN 3/16 A L3x3x1/4" AS REQUIRED TO FRAME OPENINGS THE STRUCTURE SHALL BE ADEQUATELY BRACED AND SHORED DURING ERECTION AGAINST WIND AND ERECTION LOADS. STRUCTURAL MEMBERS ARE DESIGNED FOR "IN-PLACE" LOADS ONLY. THE GENERAL CONTRACTOR SHALL VERIFY ALL OPENING SIZES, PAD SIZES, AND LOCATIONS WITH THE RESPECTIVE CONTRACTORS. A L4x4x1/4" UNDER RTU CURB (OMIT WHEN CURB IS WITHIN 2" OF JOIST) ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY AT ANY SIMILAR SITUATION ELSEWHERE ON THE JOB, EXCEPT WHERE A DIFFERENT DETAIL OR SECTION IS SHOWN. 5. 9. BEAM OR JOIST (TYP) St. Louis - Montreal (E) STEEL JOIST (E) RTU OPENING SUPPORT FRAMING 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com RTU SUPPORTS & OPENINGS B N.T.S. S1.0 mechanical electrical plumbing fire protection structural RTU FRAMING DETAIL N.T.S. D ALL DIMENSIONS AND ELEVATIONS TO EXISTING CONSTRUCTION ARE FOR REFERENCE ONLY. FIELD VERIFY DIMENSIONS AND ELEVATIONS PRIOR TO PREPARING SHOP DRAWINGS, FABRICATING MEMBERS (STRUCTURAL ITEMS), AND INSTALLATION. 2. ALL HOLES THROUGH EXISTING CONSTRUCTION SHALL BE CORE DRILLED OR SAWCUT. DO NOT CUT ANY REINFORCING STEEL WHILE DRILLING INTO EXISTING CONCRETE. DO NOT TORCH CUT. 3. PRIOR TO SUBMITTING ANY SHOP DRAWINGS, PROVIDE CERTIFICATION FROM LAND SURVEYOR REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED THAT DIMENSIONS BETWEEN NEW CONSTRUCTION AND EXISTING CONSTRUCTION HAVE BEEN SURVEYED AND FORWARDED TO SHOP DRAWING DETAILERS. 4. PRIOR TO PREPARING SHOP DRAWINGS, EXPOSE ALL FOUNDATIONS AND BUILDING FRAMING IN THE VICINITY OF NEW CONSTRUCTION AND SUBMIT LAYOUT TO ENGINEER OF RECORD. 5. NOTIFY STRUCTURAL ENGINEER IMMEDIATELY OF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND STRUCTURAL DRAWINGS. 6. FOR ALL EXISTING CONSTRUCTION: DUE TO LIMITED OBSERVATION, OR NOT BEING ABLE TO VISIT THE EXISTING BUILDING DURING THE PREPERATION OF THESE DOCUMENTS, ÆDIFICA CASE ENGINEERING HAS ASSUMED THE EXISTING STRUCTURE IS IN LIKE-NEW CONDITION WITH NO CORROSION, DETERIORATION, OR DAMAGE AND WAS CONSTRUCTED PER ANY ORIGINAL CONSTRUCTION DOCUMENTS PROVIDED (IF ANY EXIST). CONTRACTOR SHALL VERIFY THESE ASSUMPTIONS TO THE BEST OF THEIR ABILITY AND NOTIFY THE ENGINEER OF ANY CONCERNS, ISSUES OR DISCREPANCIES. (E) JOISTS L4x4x1/4" L4X4X1/4" BOLTS & HANGER ROD BY OTHERS HANGER RODS BY OTHERS BOLTS BY OTHERS C S1.0 HANGER ROD DETAIL D 3/16 HANGER ROD DETAIL D S1.0 N.T.S. N.T.S. B C SPECIAL INSPECTIONS 1. 3/16 ISSUE DATE REFER TO THE "STATEMENT OF SPECIAL INSPECTIONS" FOR THE LIST OF ELEMENTS OF CONSTRUCTION THAT SHALL REQUIRE SPECIAL INSPECTION PER IBC CODE SECTION 1704. THE OWNER SHALL EMPLOY A SPECIAL INSPECTION AGENCY APPROVED BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO THE START OF WORK. COPIES OF ALL INSPECTION REPORTS SHALL BE SUBMITTED TO THE ARCHITECT OF RECORD, STRUCTURAL ENGINEER OF RECORD, AND BUILDING INSPECTOR IN A TIMELY MANNER. 2. THE SPECIAL INSPECTIONS IDENTIFIED ON THE PLANS ARE IN ADDITION TO, AND NOT A SUBSTITUTE FOR, THOSE INSPECTIONS REQUIRED TO BE PERFORMED BY A BUILDING INSPECTOR. 3. CONTINUOUS INSPECTION SHALL BE PROVIDED DURING THE PERFORMANCE OF WORK REQUIRING SPECIAL INSPECTION, UNLESS OTHERWISE NOTED. WHEN WORK IN MORE THAN ONE CATEGORY OF WORK REQUIRING SPECIAL INSPECTION IS TO BE PERFORMED SIMULTANEOUSLY, OR THE GEOGRAPHIC LOCATION OF THE WORK IS SUCH THAT IT CANNOT BE CONTINUOUSLY OBSERVED, IT SHALL BE THE RESPONSIBILITY OF THE AGENT TO EMPLOY A SUFFICIENT NUMBER OF SPECIAL INSPECTORS TO ASSURE THAT ALL WORK IS CONTINUOUSLY INSPECTED IN ACCORDANCE WITH THOSE PROVISIONS. 1704.3 STEEL CONSTRUCTION: DOCUMENTATION: MATERIAL VERIFICIATION OF STRUCTURAL STEEL (IDENTIFICATION MARKINGS TO CONFORM TO ASTM A6 OR ASTM A568, AND MANUFACTURER'S CERTIFIED MILL TEST REPORTS); MATERIAL VERIFICATION OF THE WELD FILLER MATERIALS (IDENTIFICATION MARKING TO CONFORM TO AWS STANDARDS; MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED). CONTINUOUS INSPECTIONS: COMPLETE AND PARTIAL PENETRATION GROOVE WELDS; MULTI-PASS FILLET WELDS; SINGLE-PASS FILLET WELDS GREATER THAN 5/16" ROOT. PERIODIC INSPECTIONS: SINGLE-PASS FILLET WELDS 5/16" ROOT OR LESS; INSPECTION OF STEEL FRAME JOINT DETAILS FOR COMPLIANCE WITH APPROVED CONSTRUCTION DOCUMENTS (DETAILS SUCH AS BRACING AND STIFFENING, MEMBER LOCATIONS, AND APPLICATION OF JOINT DETAILS AT EACH CONNECTION). DATE 04-26-2016 05-23-2016 3 T-RP 600# (E) 20KCS3 - F.V. (E) 12KCS3 - F.V. (E) 22KCS2 - F.V. RTU-2 1608# DESIGN STRENGTH (E) 12KCS3 - F.V. SEE STRUCTURAL STEEL NOTES (E) 22KCS2 - F.V. (E) 12KCS3 - F.V. (E) 20KCS3 - F.V. RTU-1 1608# (E) 20KCS3 - F.V. (E) 20KCS3 - F.V. (E) 36VG6N10.0K - F.V. DESCRIPTION OF TYPE OF INSPECTION REQUIRED, LOCATION, REMARKS, ET CETERA (E) 20KCS3 - F.V. (E) 12KCS3 - F.V. (E) 36VG6N8.0K - F.V. IBC REF ISSUE DD SET 95% SET (E) 12KCS3 - F.V. STATEMENT OF SPECIAL INSPECTIONS PROJECT NUMBER: 16-059 1. S1.0 BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 (E) JOISTS EXISTING CONSTRUCTION NOTES CEILING MOUNTED TRANSFORMERS HUNG PER HANGER ROD DETAIL C & D, TYP (E) 22KCS2 - F.V. RTU OPENING PER RTU OPENING DETAILS A & B, TYP T-LP 600# 3.4 (E) 22KCS2 - F.V. SHEET TITLE ROOF FRAMING PLAN & GENERAL NOTES (E) 22KCS2 - F.V. SHEET NUMBER 1 S1.0 (E) PARTIAL ROOF FRAMING PLAN SCALE: 1/4" = 1'-0" S1.0 DESCRIPTION SUPPLY DIFFUSER RETURN GRILLE EXHAUST GRILLE T S H THERMOSTAT / SENSOR / HUMIDISTAT RECTANGULAR OR ROUND SUPPLY OR RETURN DUCT (AS NOTED) MANUAL BALANCE DAMPER ROOFTOP UNITS ROOFTOP UNITS SHALL BE FURNISHED BY PSW AND INSTALLED BY CONTRACTOR. FILTERS PROVIDE THREE (3) SETS OF PLEATED DISPOSABLE FILTERS. USE ONE SET UNTIL COMPLETION OF CONSTRUCTION. INSTALL ONE SET AT COMPLETION OF CONSTRUCTION AND DELIVER ONE SET OF FILTERS TO POTBELLY LABELED TO DENOTE THEIR RESPECTIVE AIR HANDLING UNIT. FILTERS TO BE FARR, OR SIMILAR. EXHAUST FANS PROVIDED TO THE SITE BY VENDOR. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING DISCHARGE LOCATION WITH NEW AND EXISTING VENTS AND INTAKES, PROVIDING COMPLETE INSTALLATION INCLUDING CURBS, BACKDRAFT, DAMPER AND DUCTWORK FROM RESTROOM GRILLE TO UNIT AND NECESSARY ACCESSORIES, AND PROVIDING WARRANTY. EXHAUST FAN(S) TO BE OPERATED ``IN CONJUNCTION WITH ROOFTOP UNIT(S). ROUTE FAN WIRING VIA FAN CONTROL RELAY TO BE INTERLOCKED WITH PROGRAMMABLE THERMOSTAT. PROVIDE CONTROL RELAY (HONEYWELL R8222 OR EQUIVALENT) AND 24VAC CONTROL POWER SUPPLY WITH OVERLOAD PROTECTION. INSTALL POWER SUPPLY (GENSCO #MAR24020XFMR OR EQ) AND FAN CONTROL RELAY ADJACENT TO ONE ANOTHER IN ACCESSIBLE CEILING SPACE AND EXTEND LOW VOLTAGE WIRING BETWEEN AUXILIARY RELAY PROVIDED WITH PROGRAMMABLE THERMOSTAT AND FAN CONTROL RELAY. COORDINATE ALL REQUIREMENTS WITH MECHANICAL CONTRACTOR. AIR CURTAINS AIR CURTAINS, WHEN REQUIRED, SHALL BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR. COORDINATE WITH ELECTRICAL CONTRACTOR FOR LOCATION OF POWER CONNECTION. RECTANGULAR TAKE-OFF FROM RECTANGULAR DUCT WITH BALANCE DAMPER B.O.D. DAMPER CONTROL CONTRACTOR TO ENSURE THAT ALL ELECTRICAL CONNECTIONS TO MECHANICAL DAMPERS ARE CONNECTED. AIR DEVICE DESIGNATION SEE SHEET M3.0 EQUIPMENT DESIGNATION SEE SHEET M3.0 THIS CONTRACTOR SHALL CAREFULLY REVIEW WORK LETTER TO DETERMINE SCOPE OF WORK. THIS CONTRACTOR SHALL PROVIDE ALL MATERIALS AS NECESSARY TO MAKE MODIFICATIONS TO LANDLORD PROVIDED SYSTEM. 2. THIS CONTRACTOR SHALL MODIFY EXISTING UPRIGHT SPRINKLER HEAD IN DROP CEILING(PLASTER) LOCATIONS TO FULLY RECESSED SPRINKLER HEADS. RELOCATE UPRIGHT HEADS IN OPEN CEILING AREA TO MAINTAIN FULL AREA COVERAGE. 3. THIS CONTRACTOR SHALL PROVIDE PERMITTING FOR FINAL HYDRAULIC CALCULATIONS AND HEAD LOCATIONS BASED UPON FINAL DESIGN BY CONTRACTOR AND SUBMIT TO LOCAL OR STATE BUILDING DEPARTMENT AS REQUIRED FOR APPROVAL. 4. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. DUCT SEALANT SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH A NON-HARDENING, NONMIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE RECOMMENDED BY THE MANUFACTURER FOR SEALING JOINTS AND SEAMS IN SHEET METAL DUCTWORK. COVER ALL FIELD JOINTS, JOINTS AROUND SPIN-IN FITTINGS AND FASTENING SCREWS WITH MASTIC. 5. SPRINKLER PIPING SHALL BE ROUTED TO AVOID CONFLICTS WITH NEW AND EXISTING DUCTWORK, PIPING CONDUITS AND LIGHTING LAYOUT. 6. SPRINKLER CONTRACTOR SHALL OBTAIN DUCTWORK SHOP DRAWING FROM HVAC CONTRACTOR AND COORDINATE ROUTING OF SPRINKLER PIPING. ANY RELOCATION REQUIRED BY SPRINKLER CONTRACTOR'S FAILURE TO COORDINATE SHALL BE DONE AT NO EXTRA COST OR DELAY TO THE OWNER. GENERAL CONTRACTOR TO COORDINATE. 7. FINAL CONSTRUCTION DOCUMENTS, HYDRAULIC CALCULATIONS AND PERMITTING SHALL BE BY THE SPRINKLER CONTRACTOR. 8. IF REQUIRED: INSTALL INSPECTOR TEST CONNECTIONS PIPED TO FUNNEL DRAIN OR MOP SINK. 9. ONLY ONE CONNECTION SHALL BE MADE TO MALL SPRINKLER MAIN. FIELD VERIFY EXACT LOCATION. 10. IF REQUIRED: TENANT SPRINKLER SYSTEM SHUT-OFF VALVE AND VALVE TAMPER SWITCH TO FURNISHED AND INSTALLED BY SPRINKLER CONTRACTOR. 11. SPRINKLER CONTRACTOR SHALL PERFORM ALL WORK PER LANDLORD'S CRITERIA. 12. ALL WORK TO BE APPROVED BY LOCAL FIRE DEPARTMENT. SUBMIT SHOP DRAWINGS FOR APPROVAL TO ENGINEER, TENANT, AND LOCAL FIRE DEPARTMENT. 13. ALL PERMITS FEES ETC. BY CONTRACTOR. 14. A FIRE PROTECTION ENGINEER TO PREPARE SET OF CERTIFIED STAMPED SHOP DRAWINGS OF DESIGN. 15. ALL SPRINKLER HEADS TO BE QUICK RESPONSE TYPE. 16. PROVIDE METAL CAGE OVER ALL SPRINKLERS IN COOLER / FREEZER. RECESSED/CONCEALED SPRINKLER HEAD (NEW) UPRIGHT SPRINKLER HEAD (NEW) SPLITTER DAMPER UPRIGHT SPRINKLER HEAD (ETR) UCD UNDERCUT DOOR MD MOTORIZED DAMPER SPRINKLER HEAD WITH CAGE THERMOSTAT: CONSTRUCTION AND BIDDING NOTES: 1. THE HVAC CONTRACTOR SHALL INSTALL HVAC SYSTEMS AS SHOWN, NOTED AND SPECIFIED. EQUIPMENT MAY NOT BE SUBSTITUTED UNLESS WRITTEN APPROVAL BY THE ARCHITECT, ENGINEER, OR OWNER'S REPRESENTATIVE IS OBTAINED. ANY CHANGES TO THE DUCTWORK LAYOUT WILL NECESSITATE SUBMISSION OF SHEET METAL SHOP DRAWINGS FOR ENGINEER'S REVIEW. ANY UNAUTHORIZED CHANGES WILL BE REMOVED AT CONTRACTOR'S EXPENSE, IF DEEMED NECESSARY BY ARCHITECT, ENGINEER, OR OWNER'S REPRESENTATIVE. 2. THE HVAC CONTRACTOR SHALL COORDINATE DUCTWORK INSTALLATION WITH ARCHITECT/OWNER'S REPRESENTATIVE IN FIELD AND OTHER TRADES. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND HEIGHTS. 3. ALL DUCTWORK AND PIPING SHALL BE ROUTED ABOVE THE SUSPENDED CEILING SPACE UNLESS OTHERWISE NOTED ON THE PLANS. 4. ALL OUTSIDE AIR INTAKES SHALL BE A MINIMUM OF 15'-0'' AWAY FROM EXHAUST DISCHARGE OPENINGS AND PLUMBING VENT STACKS, AND MINIMUM 10' ABOVE GRADE. 5. WHEREVER FOUNDATION WALLS, OUTSIDE WALLS, ROOFS, ETC. ARE CUT FOR INSTALLATION OF SYSTEMS, THEY SHALL BE PATCHED TO MATCH EXISTING CONSTRUCTION AND SEALED WEATHER TIGHT. WORK SHALL BE PERFORMED BY CRAFTSMEN SKILLED IN THEIR RESPECTIVE TRADES. 7. THE MECHANICAL SYSTEMS SHALL BE COMPLETE WITH ALL NECESSARY APPURTENANCES FOR A COMPLETE OPERATING SYSTEM. 8. AN INDEPENDENT AIR BALANCE CONTRACTOR SHALL ACCURATELY BALANCE THE AIR SYSTEMS TO PROVIDE AIR INDICATED ON THE DRAWINGS AND IN THIS SPECIFICATION. OPERATE AUTOMATIC CONTROLS SYSTEM AND VERIFY SET POINTS. A NEBB OR AABE CERTIFIED SUPERVISOR SHALL BE IN CHARGE OF WORK. SUBMIT TWO (2) COPIES OF THE BALANCE REPORT TO THE ENGINEER FOR APPROVAL. INCLUDE A COPY OF THE BALANCE REPORT AS APPROVED BY THE ENGINEER WITH APPLICATION FOR FINAL CONTRACT PAYMENT. THIS CONTRACTOR SHALL OBTAIN A COPY OF THE WORK LETTER FROM THE PSW CONSTRUCTION MANAGER PRIOR TO SUBMISSION OF THE BID. THIS CONTRACTOR SHALL SUBMIT SAID WORKLETTER AS EVIDENCE OF HAVING REVIEWED CONTRACTORS RESPONSIBILITIES WITHIN SCOPE OF WORK. ANY DISCREPANCIES BETWEEN THE WORKLETTER AND THE DESIGN DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE PSW CONSTRUCTION MANAGER, BEFORE BID DUE DATE. SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL AND EQUIPMENT RELATED TO THE INSTALLATION OF THE MECHANICAL WORK. 11. SITE EXAMINATION THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, DUCTWORK, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE MECHANICAL WORK. 12. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSI, SMACNA, ASHRAE, NFPA, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. 13. CORE-DRILL OR SAW-CUT EXISTING WALLS, ROOF, ETC. AS REQUIRED FOR PIPING OR DUCTWORK AND FIRE-STOP OPENING AROUND PIPE OR DUCTWORK. VERIFY LOCATION OF STRUCTURAL BEAMS, JOISTS, ETC. BEFORE DRILLING OR CUTTING. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 6. 9. 10. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE MECHANICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO POTBELLY. 1. PERMITS AND FEES THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE MECHANICAL WORK. 2. WARRANTY THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY POTBELLY AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. CONTROL WIRING THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROL WIRING IN CONDUIT NECESSARY FOR THE COMPLETE AND PROPER OPERATING TEMPERATURE CONTROL SYSTEM. THERMOSTAT THERMOSTAT(S) SHALL BE PROGRAMMABLE ZONE SENSOR, ITEM #KT7351F2127. (1) TO BE PROVIDED PER HVAC UNIT. MULTISTAGE SEVEN DAY PROGRAMMABLE THERMOSTAT. REMOTE SENSOR(S) SHALL BE HONEYWELL, ITEM #TR21-A.(2) PER HVAC UNIT. IF PSW IS PROVIDING THE HVAC UNITS, TRANE IS TO COORDINATE AND SHIP THE THERMOSTAT/SENSORS AND G.C. IS TO INSTALL. IF PSW IS NOT PROVIDING THE HVAC UNITS, THE G.C. WILL PURCHASE, SUPPLY AND INSTALL THE THERMOSTAT/SENSORS. ONE THERMOSTAT AND TWO REMOTE SENSORS TO BE PROVIDED FOR EACH HVAC UNIT. MOUNT THERMOSTAT(S) INSIDE MANAGERS DESK CUBBY AREA UNLESS OTHERWISE NOTED. MECHANICAL CONTRACTOR TO PROVIDE THERMOSTAT IDENTIFICATION WITH 81" HIGH WHITE LETTERS ON KELLY GREEN OR BLACK PHENOLIC LABELS BACKGROUND, I.E. "AC-1 : CUSTOMER AREA" AND "AC-2 : WORK AREA". REFER TO THERMOSTAT SETUP INSTRUCTIONS BELOW FOR ADDITIONAL REQUIREMENTS. THERMOSTAT SETUP INSTRUCTIONS PROVIDE THE FOLLOWING SETUP AND PROGRAMMING ON THE THERMOSTAT: 1. INSTALL PER MANUFACTURER'S IOM. 2. SET DIP SWITCHES AND JUMPERS AS FOLLOWS: A) DEGREES F DISPLAY B) 12 HOUR CLOCK C) CONTINUOUS FAN OPERATION IN OCCUPIED MODE D) DISABLE KEYBOARD PROGRAMMING E) CUT JUMPER IF UNIT IS A HEAT PUMP 3. SET CLOCK AND DAY. 4. SET TO DISPLAY CURRENT TEMPERATURE. 5. START TIMES OF UNITS SHOULD BE STAGGERED IN 15 MINUTE INTERVALS TO AVOID HIGH SPIKE USAGE, WHICH RESULTS IN A HIGHER KW CHARG TO US BY UTILITY COMPANY. STANDARD SET POINT SHOULD BE 6AM & 6:15 AM FOR NON-BREAKFAST LOCATIONS. BREAKFAST LOCATIONS SHOULD HAVE START TIMES OF 5AM & 5:15AM. SET UNOCCUPIED START TIME AT 1 HOUR AFTER CLOSING. VERIFY HOURS WITH STORE MANAGER OR CONSTRUCTION MANAGER. THESE SET POINTSCAN BE SET AT THE SAME TIME FRAME. NO NEED TO STAGGER. 6. SETPOINTS SHALL BE AS FOLLOWS: OCCUPIED UNOCCUPIED HEATING 68deg F 60deg F COOLING 70deg F 85deg F 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM R 4 0 4 S. THERMAL INSULATION PROVIDE EXTERNAL THERMAL INSULATION WITH AN INTEGRAL VAPOR BARRIER FACING OF SUFFICIENT THICKNESS TO MEET LOCAL ENERGY CODE REQUIREMENTS. PROVIDE INSULATION ON EXHAUST AND OUTSIDE AIR DUCTS, AND ON CONCEALED PORTIONS OF SUPPLY AND RETURN AIR DUCTS. DO NOT INSULATE EXPOSED DUCTWORK AND PORTIONS OF DUCTWORK THAT ARE INTERNALLY LINED. THERMAL INSULATION TO COMPLY WITH AN NFPA FLAME SPREAD OF 25 OR LESS, AND SMOKE DEVELOPED NO GREATER THAN 50. BOTTOM OF DUCT 1. A GRILLES, REGISTERS & DIFFUSERS GRILLES, REGISTERS AND DIFFUSERS SHALL BE MANUFACTURED BY TITUS AND SHALL BE GC SUPPLIED (UON). DIFFUSERS IN METAL PANEL CEILING TO BE ORDERED IN SILVER MILL FINISH. DIFFUSERS SHALL BE INSTALLED AS INDICATED ON THE DRAWINGS AND SCHEDULES. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS ITEMS NECESSARY FOR A COMPLETE AND PROPER INSTALLATION IN THE TYPE OF CEILING AND WALLS USED IN THIS PROJECT. CFM DESIGNATION NUMBER ACOUSTICAL DUCT LINER UNLESS OTHERWISE INDICATED ON THE PLANS, PROVIDE MINIMUM OF R-5.6 GLASS FIBER ACOUSTICAL DUCT LINER ON SUPPLY AND RETURN DUCTWORK WITHIN 10 FEET OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS. INCREASE DUCT SIZED INDICATED ON PLANS AS NEEDED IN EACH DIMENSION TO ACCOMMODATE LINER. LINER SHALL BE FASTENED TO DUCT WITH MECHANICAL LINER FASTENERS IN ACCORDANCE WITH SMAGNA. DAMPERS PROVIDE OPPOSED-BLADE, MULTI-LEAF VOLUME CONTROL DAMPERS WHERE INDICATED ON DRAWINGS AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN AND EXHAUST DUCTS WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS. PROVIDE UL LISTED AND FIRE/SMOKE DAMPERS WHERE REQUIRED AND IN ACCORDANCE WITH NFPA AND LOCAL CODES. PROVIDE CONVENIENTLY LOCATED ACCESS DOORS OF AMPLE SIZE AND QUANTITY FOR SERVICING THE DAMPERS. INSTALL PER UL GUIDELINES. TURNING VANES EQUIPMENT TYPE SHEETMETAL DUCTWORK ALL DUCTWORK TO BE RIGID SHEET METAL CONSTRUCTED FROM GALVANIZED SHEET STEEL IN ACCORDANCE WITH SMACNA LOW VELOCITY DUCT CONSTRUCTION STANDARDS. FIBERGLASS DUCTBOARD IS NOT ALLOWED. ALL EXPOSED DUCTWORK TO BE ROUND, SPIRAL, OR RECTANGULAR LOCK-SEAM TYPE, AS SHOWN ON HVAC PLAN SHEET M2.0. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT (5% LEAKAGE) AND NOISELESS (NO OBJECTIONABLE NOISE SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SERVICE. FURNISH ALL REQUIRED DAMPERS, TRANSITIONS, CONNECTIONS TO AIR TERMINALS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE OPERATING SYSTEM. NO VARIATION OF DUCT CONFIGURATION OR SIZES WILL BE PERMITTED EXCEPT BY PERMISSION FROM THE ENGINEER. MOUNT DUCTWORK AS HIGH AS POSSIBLE TO UNDERSIDE OF STRUCTURE. (NO SQUARE THROAT ELBOWS SHALL BE INSTALLED WITHOUT DOUBLE THICKNESS TURNING VANES.) ALL DUCT CONNECTIONS TO EQUIPMENT SHALL BE LOADED TYPE VINYL, VIBRATION ELIMINATION CONNECTIONS, (F.C.) FLEXIBLE CONNECTIONS. DUCTWORK TRANSITIONS SHALL BE (FOT) ''FLAT ON TOP'' UNLESS OTHERWISE SPECIFIED ON PLAN. ALL BRANCH SUPPLY DUCTS SHALL HAVE (VD) MANUAL VOLUME DAMPERS INSTALLED FOR BALANCING, SEE SYMBOL LIST. ALL ROOF PENETRATIONS EXCEEDING 12'' X 12'' IN SIZE SHALL BE FURNISHED WITH BURGLAR BARS. ALL CONTRACTOR FABRICATED AND MANUFACTURER FABRICATED COMPONENTS OF THE OUTSIDE AIR, SUPPLY AIR, RETURN AIR AND EXHAUST SYSTEMS SHALL BE CONSTRUCTED AND INSTALLED AIR-TIGHT. THE INSTALLED SYSTEMS SHALL BE PRESSURE TESTED AS SPECIFIED. PIPE OPENINGS IN SYSTEM COMPONENT SHALL HAVE SHEET METAL BAFFLES, SET IN SEALANT, TO PREVENT LEAKAGE. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR OUTSIDE DIMENSIONS. SUPPORTS PROVIDE HOT-DIPPED GALVANIZED STEEL, FASTENERS, ANCHORS. RODS, STRAPS, TRIM, AND ANGLES FOR SUPPORT OF DUCTWORK. ROUND TAKE-OFF FROM DUCT WITH MANUAL BALANCE DAMPER DEVICE TYPE FIRE PROTECTION SYSTEM: DUCTWORK & ACCESSORIES: WALK IN FREEZER/COOLER: 7. ALL NEW SUPPLY, RETURN AND OUTSIDE AIR RECTANGULAR/SQUARE DUCTWORK SHALL BE INSULATED WITH 1'' THICK, 2 PCF DUCT LINER. DUCT LINER SHALL BE FASTENED TO INSIDE OF DUCTWORK AS PER MANUFACTURER'S DIRECTIONS AND S.M.A.C.N.A. ''DUCT LINER APPLICATION STANDARD''. ALL NEW SUPPLY, RETURN AND OUTSIDE AIR ROUND/OVAL DUCTWORK , WHICH ARE NOT LINED, SHALL BE INSULATED WITH 1-1/2'' THICK FLEXIBLE INSULATION, 1 PCF DENSITY FOIL REINFORCED KRAFT FACING. DUCT WRAP SHALL BE FASTENED TO DUCTWORK AS PER MANUFACTURER'S DIRECTIONS. THE ROUND BRANCH DUCTWORK SHALL BE INSULATED WITH 1'' THICK FIBERGLASS SLEEVE WITH FOIL JACKET AND ALL JOINTS AND TERMINATIONS SEALED WITH FOIL OR DUCT TAPE. ROUND/OVAL SUPPLY AND RETURN DUCTWORK EXPOSED TO VIEW AND LOCATED IN THE CONDITIONED SPACE SHALL NOT BE INSULATED. EXTERIOR DUCTWORK TO BE 1-1/2" LINED AND WEATHERPROOFED. DUCTS TO BE LINED: a.) ALL RECTANGULAR CONCEALED AND EXPOSED SUPPLY DUCTWORK. b.) ALL RETURN DUCT WORK FROM GRILLES TO ROOFTOP UNITS c.) ALL EXHAUST DUCT RISERS TO ROOF FANS AND FOR A DISTANCE OF 5'-0" FROM VERTICAL DUCT CONNECTION. d.) ANY OTHER DUCTWORK SPECIFICALLY NOTED ON THE CONTRACT DRAWINGS. 8. ALL FLEXIBLE DUCTWORK SHALL BE FACTORY ASSEMBLED CLASS 1 AIR DUCT (UL 181) WITH FIBERGLASS INSULATION AND REINFORCED OUTER PROTECTIVE COVER/VAPOR BARRIER. FLEX DUCT SHALL MEET NFPA 90A WITH FLAME SPREAD UNDER 25, SMOKE DEVELOPED UNDER 50, AND SHALL BE RATED FOR 2'' W.C. PRESSURE AND 0 TO 250 DEGREE TEMPERATURE. MAXIMUM STRETCHED OUT LENGTH SHALL BE 6'-0''. COOLER INFORMATION THE VOLUME OF THE COOLER IS 541.3 CUBIC FEET. THE COOLER USES 2.9 POUNDS R-22 REFRIGERANT. THE COOLER HAS A 1 HP MOTOR AND THE COMPRESSOR IS A REMOTE THAT IS MOUNTED ON THE ROOF. FREEZER INFORMATION THE VOLUME OF THE FREEZER IS 230.4 CUBIC FEET. THE FREEZER USES 3.5 POUNDS R-404a REFRIGERANT. THE FREEZER HAS A 1.5 HP MOTOR AND THE COMPRESSOR IS A REMOTE THAT IS MOUNTED ON THE ROOF. C H Wells S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. St. Louis - Montreal 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com mechanical electrical plumbing fire protection structural ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 ENERGY CODE COMPLETION: DRAWINGS WITHIN 90 DAYS OF SYSTEM ACCEPTANCE, CONTRACTOR SHALL PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO THE BUILDING OWNER OR THE DESIGNATED REPRESENTATIVE OF THE BUILDING OWNER. RECORD DRAWINGS INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM INCLUDING SIZES, AND THE TERMINAL AIR OR WATER DESIGN FLOOR RATES. MANUAL WITHIN 90 DAYS OF SYSTEM ACCEPTANCE, CONTRACTOR SHALL PROVIDE AN OPERATING AND MAINTENANCE MANUAL TO THE BUILDING OWNER, OR DESIGNATED REPRESENTATIVE OF THE BUILDING OWNER. THESE MANUALS SHALL BE IN ACCORDANCE WITH INDUSTRY ACCEPTED STANDARDS AND SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING: - SUBMITTAL DATA STATING EQUIPMENT SIZES AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. - OPERATIONS MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE EXCEPT EQUIPMENT NOT FURNISHED AS PART OF THE PROJECT. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. - NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY. - HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS AND CONTROL SEQUENCE DESCRIPTIONS. DESIRED OR FIELD DETERMINED SET-POINTS SHALL BE PERMANENTLY RECORDED ON CONTROL DRAWINGS AT CONTROL DEVICES OR FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS. - A COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE, INCLUDING SUGGESTED SET-POINTS. E 955 PROJECT NUMBER: 16-059 DETAIL ROOFTOP UNIT EQUIP. & MATERIALS: BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 HVAC SYMBOLS LEGEND SHEET TITLE MECHANICAL LEGEND & NOTES SHEET NUMBER M1.0 KEYNOTES 3 PROVIDE MANUAL VOLUME DAMPER TO AIR DEVICE. TYPICAL FOR ALL "S1" GRILLES. 4 PROVIDE SMOKE DETECTOR IN MAIN RETURN DUCT OF RTU WHICH WILL DE-ENERGIZE THE UNIT UPON SMOKE DETECTION. INTERLOCK WITH FIRE ALARM SYSTEM IF APPLICABLE. VERIFY ALL REQUIREMENTS WITH LOCAL CODES & LANDLORD. 5 RTU-1, RTU-2 2 ROOFTOP UNITS FURNISHED BY PSW & INSTALLED BY CONTRACTOR. BALANCE SUPPLY, RETURN AND OUTDOOR AIR FLOWS PER SCHEDULE ON SHEET M3.0. PROVIDE WITH 3 SETS OF FILTERS FOR EACH UNIT - ONE SET FOR USE DURING CONSTRUCTION, ONE SET INSTALLED AT COMPLETION OF CONSTRUCTION AND ONE SPARE SET FOR TENANT. 6 EF-1 EXHAUST FAN & KITCHEN EXHAUST HOOD PROVIDED BY VENDOR & INSTALLED BY CONTRACTOR. CONTRACTOR TO MAKE ALL CONNECTIONS BETWEEN HOOD AND EXHAUST FAN. CONTRACTOR RESPONSIBLE FOR COORDINATION BETWEEN LANDLORD AND ROOFING CONTRACTOR. 7 DUCT CONNECTIONS TO RTU SHALL BE MADE FULL SIZE OF EQUIPMENT OPENING WITH FLEXIBLE DUCT CONNECTIONS AT UNIT AND THEN TRANSITION TO THE SIZES AND LOCATIONS SHOWN. TYPICAL FOR SUPPLY AND RETURN DUCTS. 8 SPRINKLER HEADS SEE SHEET M1.0. 9 MOUNT DUCTWORK AS HIGH AS POSSIBLE. VERIFY MOUNTING HEIGHT OF DUCTWORK WITH ARCHITECT. 10 16" DIA. EXHAUST DUCT UP FROM HOOD, WITH VOLUME DAMPER, TO 18" DIA. DUCTWORK UP TO EXHAUST FAN EF-1 ON ROOF. VERIFY LOCATION IN FIELD WITH LANDLORD REPRESENTATIVE. 11 FURNISH AND INSTALL GALVANIZED STEEL DUCTWORK, SIZES AS SHOWN ON DRAWINGS. SIZES SHOWN ARE SHEET METAL SIZES. INSULATE ALL RECTANGULAR DUCTWORK ABOVE CEILINGS WITH 1-1/2" EXTERNAL WRAP WITH VAPOR BARRIER. SEE SHEET M4.0 FOR DETAILS. 12 SUPPLY DUCT CONNECTION TO AIR DEVICE. SEE AIR DEVICE RUNOUT SCHEDULE FOR SIZE. INSTALL A VOLUME DAMPER AT TAKE-OFF FROM SUPPLY DUCT MAIN. TYPICAL FOR ALL "S2" GRILLES. 13 EXHAUST DUCT, 8"x8", UP TO EXHAUST FAN EF-2 ON ROOF. VERIFY LOCATION IN FIELD. 14 4" PVC/CPVC INTAKE AND 4" PVC/CPVC EXHAUST UP TO ROOF. COMBINE RIGHT BEFORE ROOF PENETRATION WITH CONCENTRIC VENT KIT. 15 FURNISH AND INSTALL HUMIDITY SENSOR IN RETURN AIR DUCT TO MAINTAIN 50% RELATIVE HUMIDITY IN SPACE. S 10 12 15 H 7 15 NOTES: VERIFY EXHAUST DUCT TERMINATIONS ARE A MINIMUM OF 10'-0" AWAY FROM ANY OUTSIDE AIR INTAKES FOR BUILDING. 10 H 4 7 5 1 13 A R 4 0 4 S. C H Wells S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 R ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. St. Louis - Montreal 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com ISSUE DD SET 95% SET S 14 mechanical electrical plumbing fire protection structural DATE 04-26-2016 05-23-2016 8 3 2 S S 1 1 SHEET TITLE MECHANICAL PLAN NORTH SHEET NUMBER SCALE: 1/4"=1'-0" S 0334 ISSUE DATE 11 MECHANICAL PLAN 01 E 955 4 5 9 11 6 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM PROJECT NUMBER: 16-059 2 SEE SUBMARINE DETAIL DRAWING 10/M4.0. SEE ARCHITECTURAL DRAWINGS FOR SUBMARINE HANGING INSTRUCTIONS. 24 HOURS PRIOR TO INSTALLATION CONTRACTOR SHALL CONTACT OWNERS PROJECT MANAGER FOR EXACT INSTALLATION ANGLES. SUBMARINE IS MADE OF SHEET METAL DUCTWORK. SUBMARINE IS ATTACHED IN THE SAME FASHION AS DUCTWORK. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 THERMOSTAT INSTALL THERMOSTAT AND AVERAGING REMOTE SENSORS AS SHOWN. COORDINATE EXACT LOCATION WITH OWNER REP. MOUNT T-STATS AS INDICATED ON DWGS. MOUNT SENSORS AT 60" A.F.F. U.N.O. IN LOCKABLE ENCLOSURE. COORDINATE WITH ELECTRICAL CONTRACTOR FOR BACKBOX. CONTRACTOR TO VERIFY COMPATIBILITY AND WIRE T-STATS AND SENSORS TO HVAC UNITS. 1 T T 1 12 1 M2.0 AIR DEVICE SCHEDULE ROOFTOP UNIT SCHEDULE HEATING TAG MANUF / MODEL CFM O.A. CFM E.S.P. VOLTS/ PHASE RTU-1 TRANE YHC120 3400 1150 0.6 460 RTU-2 TRANE YHC120 3400 1150 0.6 460 FAN HP 3 3 MCA/MOCP 3.6 24.9 3.6 24.9 EER/SEER INPUT OUTPUT MBH MBH 12.5 30 12.5 30 - COOLING NOM. TONS TOTAL MBH SENS. MBH ENT. D.B. ENT. W.B. UNIT WEIGHT REMARKS 250 200 10.0 109.4 83.5 76°F 66°F 1608 1, 2, 3, 4 250 200 10.0 109.4 83.5 76°F 66°F 1608 1, 2, 3, 4 MARK RECT. NECK SIZE ROUND NECK SIZE FACE SIZE S1 10X8" - 3 13X916 " S2 - SCHEDULE 24X24" S3 - SCHEDULE S4 - SCHEDULE THROW PATTERN MOUNTING MANUFACTURER/MODEL NOTES DUCT METALAIRE 4004P-1 1 4-WAY CEILING TITUS PAS 1 24X24" 4-WAY CEILING TITUS TDC 1 12X12" 4-WAY CEILING TITUS TDC 1 R1 - SCHEDULE 24X24" - CEILING TITUS 355RL R2 18X16" SCHEDULE 20X18" - WALL TITUS 355ZRL E1 - 8" DIA 12X12" 4-WAY CEILING TITUS 355RL E2 - 6" DIA 12X12" 4-WAY CEILING TITUS 355RL 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM 1 A A. DEVICES SHALL BE WHITE FROM THE MANUFACTURER AND PAINT TO MATCH CEILING OR WALL. B. DEVICES SHALL BE SILVER MILL FINISH FROM THE MANUFACTURER WHEN IN METAL PANEL CEILING SYSTEM. C. ALL DEVICES SHALL BE 4-WAY UNLESS SHOWN OTHERWISE H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 E 955 R S 0334 D. CONTRACTOR IS RESPONSIBLE FOR VERIFING QUANTITIES AS SHOWN ON PLANS. THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. NOTES: 1. C Wells ILLINOIS DESIGN FIRM # 184.006688 GENERAL NOTES: NOTES: 1. VERIFY EXISTING ELECTRICAL WITH ELECTRICAL CONTRACTOR. 2. ROOFTOP UNITS PROVIDED BY PSW AND INSTALLED BY CONTRACTOR. UNIT TO BE PROVIDED WITH FULL ECONOMIZER, BAROMETRIC RELIEF DAMPER & EXPANDED METAL HAIL GUARDS. VERIFY LOCATION AND PROPER OPERATION WITH LANDLORD REPRESENTATIVE. ROOFTOP UNIT CONVENIENCE OUTLET SHALL BE GFI. 3. INSTALL DUCT SMOKE DETECTORS, FIELD INSTALLED AS SHOWN ON PLANS. RTU SHALL SHUT DOWN AND SIGNAL FIRE ALARM SYSTEM (IF APPLICABLE) WHEN ACTIVATED. 4. PROVIDE UNIT WITH HOT GAS REHEAT OPTION AND HUMIDITY SENSOR. SEE PLANS ON SHEET M2.0 FOR HUMIDITY SENSOR LOCATION. R 4 0 4 S. PROVIDE WITH DAMPER. St. Louis - Montreal EXHAUST HOOD SCHEDULE EXHAUST PLENUM RISER(S) HOOD SIZE TOTAL EXH. CFM DIAMETER CFM S.P. HOOD WEIGHT FAN SERVING HOOD HOOD CONSTRUCTION REMARKS KH-1 GREASEMASTER 3624 5'-0" L X 3'-0" 1000 16" 1000 -0.086 136 LBS EF-1 430 SS WHERE EXPOSED 1 KH-2 GREASEMASTER 3624 5'-0" L X 3'-0" 1000 16" 1000 -0.086 136 LBS EF-1 430 SS WHERE EXPOSED 1 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com AIR DEVICE RUNOUT SCHEDULE NOTES: 1. EXHAUST FANS & KITCHEN HOODS PROVIDED BY PSW VENDOR AND INSTALLED BY CONTRACTOR. SEE SHEET M6.0 FOR ADDITIONAL INFORMATION. DUCT CFM 0 - 100 101 - 230 231 - 420 421 - 680 681 - 1030 1031 - 1450 1451 - 2000 2001 - 2600 FAN SCHEDULE MARK CFM S.P. EF-1 2000 .75" VOLTS/PHASE 115 FAN HP AREA SERVED MANUFACTURER/MODEL WEIGHT NOTES .75 KH-1 & KH-2 GREASEMASTER GM14-FA 134 SEE SHEET M6.0 FOR FULL DETAIL/SPECIFICATION .06 TOILET ROOMS GREASEMASTER GMDR10H 36 SEE SHEET M6.0 FOR FULL DETAIL/SPECIFICATION 1 EF-2 200 .375" 115 1 BDD = BACKDRAFT DAMPER DS = NON-FUSED SERVICE DISCONNECT BS = BIRDSCREEN EC = EPOXY COATING DDP = DOWN DISCHARGE PLENUM FILT = PERMANENT FILT. DIT = DUCT INLET TRANSITION GB = GREASEBOX MEP= MASTER ELECTRIC PANEL SI = SIDE INLET RC = ROOF CURM SIT = SIDE INLET TRANSITION SCR = SPEED CONTROL WD = WEATHER HOOD SD = SIDE DISCHARGE PE = PREMIUM EFFICIENCY MOTOR WC = WALL CAP mechanical electrical plumbing fire protection structural DUCT SIZE 6" ROUND 8" ROUND 10" ROUND 12" ROUND 14" ROUND 16" ROUND 18" ROUND 20" ROUND GENERAL NOTES 1. AIR DEVICE NECK SIZE SHALL BE THE SAME AS RUNOUT SIZE. 2. RECTANGULAR DUCT SIZES OF EQUIVALENT FREE AREA MAY BE BE SUBSTITUTED FOR ROUND DUCT. 2. RUNOUTS MAY BE RIGID OR FLEX DUCT PER SPECIFICATIONS. AIR BALANCE SCHEDULE TAG OUTSIDE AIR RETURN AIR SUPPLY AIR EXHAUST AIR PRESSURE PERCENT OUTSIDE AIR RTU-1 1150 2250 3400 0 +1150 34% RTU-2 1150 2250 3400 0 +1150 34% EF-1 0 0 0 2,000 -2,000 --- EF-2 0 0 0 200 -200 --- TOTAL: PROJECT NUMBER: 16-059 MANUF / MODEL BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 TAG +100 ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 SHEET TITLE MECHANICAL SCHEDULES SHEET NUMBER M3.0 LIQUID RECEIVER NOTE: DIVE TO 20 DEGREE CANT. 24 HOURS PRIOR TO INSTALLATION CONTRACTOR SHALL CONTACT OWNER'S PROJECT MANAGER FOR EXACT INSTALLATION ANGLES. PROPELLAR TO SPIN FREELY WITH AIR FLOW. TRAPEZE HANGERS RELIEF/SAFETY VALVE ROD 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM 10"~ TO 6"~ TALL CONE CAP CONDENSING UNIT NAILER 6"~ TO 2-1/2"X12" HORN BOOT 1" WIDE, 18 GA. SUPPORT STRAP w/ 5'-0" MAXIMUM SPACING STRAP HANGERS 60" MAX. (EXPOSED DUCTWORK ONLY, USE RECTANGULAR DUCT IF ABOVE CEILING) CONTINUOUS HANGER STRAP AROUND DUCT ROUND DUCT SUPPORT DETAIL 4" Scale: N.T.S. Ø1'- 2'-6" 4 Scale: N.T.S. 7 WALK-IN COOLER PIPING DIAGRAM Scale: N.T.S. 4" 10 45° CLINCH COLLAR WITH GASKET ~ O PLAN VIEW 18" ENCLOSURE PANEL (SHIPPED LOOSE) CFL LIGHT (INTEGRAL) MESH FILTER HANGER BRACKET ROUND DUCTS R=3W/2 (CENTERLINE STD RADIUS) RECTANGULAR DUCTS R1 MIN. 4", R2=R1 + W TYPICAL MANUAL VOLUME DAMPER REFER TO SPECIFICATIONS FOR PRESSURE AND SEAL CLASSIFICATIONS R R2 1'-6" 1'-6" S + IL P L A 60607 N N P: 312 3'-0" SUPPLY OR RETURN DUCT Scale: N.T.S. 11 ISSUE DD SET 95% SET NOT USED Scale: N.T.S. SHOP FABRICATED SHT MTL CLG DIFUSSER CAP NET INSIDE DIM. SAME AS DIFFUSER NECK FRONT VIEW OPPOSED BLADE DAMPER TITUS AG-75 OR EQUAL WHEN REQ'D EQUALIZING GRID PERPEND TO STUB DUCT. FULL SIZE OF DIFFUSER CAP. HEIGHT FROM DIFFUSER NECK TO STUB CNTRLN. FABRICATE FROM 22GA PERF SHT MTL (163 " HOLES ON 41" CNTRS). 7'-0" -ONE UNIT REQUIRED PER OVEN LOCATION NOTE: HOOD AND EXHAUST FANS BY VENDOR; DUCTS BY G.C. EQUIPMENT BY OTHERS EXPOSED MATERIAL: 18 GA TYPE 430 S/S, #3 POLISH LIGHTS: (2) CFL (INTEGRAL-BULBS SUPPLIED) BY VENDOR FILTERS: (1) 20x20 ALUMINUM MESH CONTROLS: FAN SPEED CONTROLLER, ON-OFF LIGHTED LIGHT SWITCH SWITCHES TO BE LOCATED AT MASTER SWITCH BANK EXHAUST: 300-1000 CFM NOTES: 1. PROVIDE SUPPORT FOR DIFFUSER & CAP PER CODE FLEX DUCT CLAMP FLEX DUCT. PULL INSIDE LINER TAUT CLG DIFFUSER. FASTEN TO CAP W/ SHT MTL SCREWS, MIN ONE PER SIDE. SEAL JOINT AIR TIGHT SHEET TITLE MECHANICAL DETAILS 2. EQUALIZING GRID REQ'D ON SUPPLY AIR DIFFUSERS ONLY TYP SUSP LAY-IN CEILING SHEET NUMBER SIDE VIEW 3 TYPE II KITCHEN HOOD Scale: N.T.S. 9 R S 0334 DATE 04-26-2016 05-23-2016 ROUND INSUL STUB DUCT SAME SIZE AS FLEX DUCT 5'-0" E 955 mechanical electrical plumbing fire protection structural 6" 6" T Chicago, ISSUE DATE W 8 C R1 3" 3" HANGER BRACKET 18" ENCLOSURE PANEL (SHIPPED LOOSE) E 300 Scale: N.T.S. 3'-0" 6" 5'-0" T Suite SUBMARINE DETAIL TYPICAL ROUND DUCT STANDARD BELLMOUTH ECCENTRIC TRANSITION ~ Ω=30° MAX I 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com AD ACCESS DOOR WITH PIANO HINGE AND SASH LOCK 4'-0" S t ., St. Louis - Montreal SOLID ROUND ELBOW 1'-6" 2'-0" 2-1/2"X12" REG. TAPERED 4" 6" H THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. VERTICAL RETURN DUCT EXHAUST C Wells ROOM DIFFUSER OR REGISTER TYPE RE2 SQUARE THROAT ELBOW WITH DOUBLE WALL VANES VERTICAL SUPPLY DUCT R 4 0 4 S. ILLINOIS DESIGN FIRM # 184.006688 1/2" HOLES DRILLED INTO COVER NOTES: 1. REMOVE EXPANSION VALVES, DEVICES AND CONNECTIONS FROM THE AIR STREAM. 2. INSTALL PRESSURE RELIEF VALVE ON HIGH PRESSURE SIDE OF SYSTEM, UPSTREAM FROM ANY LIQUID LINE SHUT-OFF VALVES. 3. REFRIGERATION PIPING TO BE TYPE 'K' COPPER. 4. ALL REFRIGERATION PIPING JOINTS TO BE BRAZED. 5. VERIFY REFRIGERANT LINE SIZE PER MANUFACTURERS INSTALLATION INSTRUCTIONS PRIOR TO INSTALLATION. 6. GC TO PROVIDE ANY NECESSARY CONDUIT AND PENETRATIONS. FIRE DAMPER STYLE B, WITH DAMPER CURTAIN OUT OF AIRSTREAM. CONSTRUCTION AS PER NFPA90A A PROPELLER EXPANSION VALVE UNIT COOLER (EVAPORATOR COIL) DUCT SUPPORT DETAIL 12"~ TO 8"~ TALL CONE LIQUID LINE, 3/8" O.D. "K" COPPER UNLESS FOOT OF STRAP IS PLACED UNDER A BOTTOM REINFORCEMENT 6"~ TO 2-1/2"X12" HORN BOOT BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 ROUND RIGID DUCT SUCTION LINE, 5/8" O.D. "K" COPPER HANGER STRAPS 1 2-1/2"X12" REG. TAPERED JOIST SIZE BOLT(S) FOR LOAD 12"~ SPIRAL DUCT PROJECT NUMBER: 16-059 STRAP OR ANGLE 3"~ ELBOW LAY-IN CLG DIFFUSER Scale: N.T.S. 12 NOT USED Scale: N.T.S. 13 NOT USED Scale: N.T.S. M4.0 KEYNOTES 1 NEW ROOFTOP UNIT, RTU-1. VERIFY EXACT LOCATION AND PROPER OPERATION IN FIELD. 2 NEW ROOFTOP UNIT, RTU-2. VERIFY EXACT LOCATION AND PROPER OPERATION IN FIELD. 3 NEW EXHAUST FAN, EF-1, FOR KITCHEN HOOD. 4 NEW EXHAUST FAN, EF-2, FOR TOILET ROOMS. 5 FLUE FROM WATER HEATER. 6 NEW REMOTE CONDENSER FOR COOLER/FREEZER. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. C H Wells S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. St. Louis - Montreal 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com 2 1 4 3 PROJECT NUMBER: 16-059 BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 mechanical electrical plumbing fire protection structural 6 ISSUE DATE 6 ISSUE DD SET 95% SET 5 DATE 04-26-2016 05-23-2016 SHEET TITLE NORTH 01 MECHANICAL ROOF PLAN MECHANICAL ROOF PLAN SHEET NUMBER SCALE: 1/4"=1'-0" M5.0 REVISIONS 3624 1 GC-1 3624 2 MAX. COOKING TEMP. TOTAL EXH. CFM 5' 0.00" 300 Deg. 5' 0.00" 300 Deg. LENGTH GC-1 WIDTH LENG. DIA. CFM S.P. 1000 4" 16" 1000 -0.086" 1000 4" 16" 1000 -0.086" FILTER(S) HOOD NO. TAG TYPE QTY. HOOD CONSTRUCTION HEIGHT HEIGHT 430 SS 100% 430 SS 100% END TO END ROW FAN UNIT NO. TAG FAN UNIT MODEL # CFM ESP. RPM H.P. B.H.P. Ø VOLT FLA WEIGHT (LBS.) SONES ALONE ALONE 1 EF-1 GM14-FA 2000 0.750 1283 0.750 0.6900 1 115 6.8 134 14.9 ALONE ALONE 2 EF-2 GMDR10H 200 0.375 1351 0.060 0.0490 1 115 1.0 36 4.9 FAN UNIT NO. TAG 1 EF-1 2 EF-2 LIGHT(S) LENGTH EFFICIENCY @ 9 QTY. MICRONS TYPE WIRE GUARD UTILITY CABINET(S) FIRE SYSTEM LOCATION SIZE TYPE SIZE ELECTRICAL SWITCHES MODEL # QUANTITY FIRE SYSTEM PIPING HOOD HANGING WGHT 1 2 Screw In Compact NO NO 136 LBS 2 2 Screw In Compact NO NO 136 LBS 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM OPTION (Qty. - Descr.) LISTED MODEL BUILT IN ACCORDANCE WITH NFPA No. 96 TAG HOOD CONFIG. R HOOD NO. EXHAUST PLENUM RISER(S) 1 - I 19-BDD Damper 1 - SCR-15 Bird Screen A 1 - I 12-BDD Damper R 4 0 4 S. C Wells H I S t ., T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 HOOD NO. 1 2 TAG OPTION WRAPPER CHANNEL - Front, Left, Right, Back NO. ON FAN WEIGHT ITEM 1 #1 29 LBS Curb 23.000"W x 23.000"L x 18.000"H 2 #2 22 LBS Curb 17.500"W x 17.500"L x 18.000"H THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. SIZE WRAPPER CHANNEL - Front, Left, Right, Back OPTIONS ONLY: FIELD WRAPPER 18.00" High x 24.00" Long Left 430 SS OPTIONS ONLY: FIELD WRAPPER 18.00" High x 48.00" Long Front 430 SS FAN #1 GM14-FA - EXHAUST FAN (EF-1) St. Louis - Montreal OPTIONS ONLY: FIELD WRAPPER 18.00" High x 24.00" Long Right 430 SS OPTIONS ONLY: FIELD WRAPPER 18.00" High x 48.00" Long Back 430 SS 23" OPTIONS ONLY: FIELD WRAPPER 18.00" High x 24.00" Long Left 430 SS 33 3/4 FEATURES: OPTIONS ONLY: FIELD WRAPPER 18.00" High x 48.00" Long Front 430 SS OPTIONS ONLY: FIELD WRAPPER 18.00" High x 24.00" Long Right 430 SS - ROOF MOUNTED FANS OPTIONS ONLY: FIELD WRAPPER 18.00" High x 48.00" Long Back 430 SS - UL705 23" 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com - AMCA SOUND AND AIR CERTIFIED mechanical electrical plumbing fire protection structural CURB - INTERNAL WIRING - WEATHERPROOF DISCONNECT 18" - THERMAL OVERLOAD PROTECTION (SINGLE PHASE) I 19-BDD DAMPER SCR-15 BIRD SCREEN 23 3" FLANGE BACKDRAFT DAMPER INSTALLATION 2 AIR FLOW ROOF OPENING DIMENSIONS 21 BACKDRAFT DAMPER 21 14 7/8 21 24 3/4 21 (ROOF OPENING) 17 1/2" 17 1/2" FEATURES: - DIRECT DRIVE CONSTRUCTION 20 3/4 (NO BELTS/PULLEYS) - ROOF MOUNTED FANS CURB - UL705 18" - SAFETY DISCONNECT - STANDARD BIRD SCREEN 20 GAUGE STEEL CONSTRUCTION - SPEED CONTROL OPTIONS I 12-BDD DAMPER 14 1/2 3" FLANGE 13 13 HOOD IS TYPE II-NON GREASE 8 1/8 13 2 ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 BACKDRAFT DAMPER INSTALLATION DATE: AIR FLOW 19 HOOD & FAN PACKAGE PROVIDED DIRECT TO OWNER. CONTACT DIRK BAUMANN @ J.D. HIGGINS COMPANY FOR ADDITIONAL INFORMATION @ 800-772-5452 ROOF OPENING DIMENSIONS ISSUE DATE LINTHICUM HEIGHTS, MD, 21090 FAN #2 GMDR10H - EXHAUST FAN (EF-2) PROJECT NUMBER: 16-059 30 1/2 BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 20 GAUGE STEEL CONSTRUCTION OPTIONS Potbelly- Linthicum Heights, MD 3 BACKDRAFT DAMPER DWG.#: 2661219 DRAWN BY: SCALE: SHEET TITLE MASTER DRAWING EXHAUST HOOD DRAWINGS SHEET NO. SHEET NUMBER 13 (ROOF OPENING) M6.0 SOIL, WASTE AND VENT PIPING SOIL, WASTE AND VENT PIPING 10" AND SMALLER SHALL BE SERVICE WEIGHT, HUBLESS, CAST IRON PIPE AND FITTINGS WITH NEOPRENE GASKET AND STAINLESS STEEL SHIELD AND CLAMP. PROVIDE HUB & SPIGOT, SERVICE WEIGHT CAST-IRON SOIL PIPE AND FITTINGS BELOW GRADE WHERE REQUIRED BY LOCAL CODES. ALL HORIZONTAL RUNS SHALL DRAIN AT A GRADE 41" PER FOOT. COORDINATE WITH LOCAL AUTHORITIES FOR DRAINAGE REQUIREMENTS FOR EQUIPMENT DESIGNATED WITH INDIRECT WASTE TO FLOOR DRAINS. PROVIDE PIPED DRAIN TO SANITARY IF REQUIRED BY LOCAL JURISDICTION. WATER SERVICE COLD WATER SUPPLY PIPING HOT WATER SUPPLY PIPING HOT WATER RETURN PIPING SANITARY DRAINAGE & WASTE PIPING/SEWER DOMESTIC WATER PIPING DOMESTIC WATER PIPING 221" AND SMALLER SHALL BE COPPER TUBE WITH WROUGHT COPPER SWEAT FITTINGS JOINED WITH NON-LEAD, NON-ANTIMONY SOLDER. PROVIDE TYPE "L" COPPER TUBE ABOVE GRADE AND TYPE "K" BELOW GRADE. SANITARY VENT PIPING NATURAL GAS PIPING G CONDENSATE DRAINAGE PIPING THE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAINS FOR AIR HANDLING UNITS AND POTBELLYS EQUIPMENT (REFER TO SCHEDULE). CONDENSATE DRAINAGE PIPING SHALL BE TYPE "M" COPPER TUBING WITH WROUGHT COPPER SWEAT FITTINGS JOINED WITH 50/50 SOLDER. LINE SIZE GATE VALVE LINE SIZE BALL VALVE (2'' & SMALLER) LINE SIZE CHECK VALVE HANGERS & SUPPORTS THE PLUMBING CONTRACTOR SHALL FURNISH ALL PIPE SUPPORTS REQUIRED FOR EQUIPMENT AND MATERIAL. ALL HORIZONTAL RUNS OF PIPING SHALL BE SUPPORTED BY PIPE HANGERS INSTALLED AS REQUIRED BY LOCAL CODES ADDITIONAL SUPPORTS SHALL BE PROVIDED WHERE REQUIRED TO PREVENT SAGGING. HANGERS AND PIPE ATTACHMENTS TO BE FACTORY FABRICATED WITH GALVANIZED COATINGS; NONMETALLIC COATED FOR HANGERS IN DIRECT CONTACT WITH COPPER TUBING. LINE SIZE UNION LINE SIZE GAS COCK VALVE ABOVE FINISHED FLOOR CB CAST BRASS CIP CAST IRON PIPE CI CAST IRON CO CLEANOUT CP CHROME PLATED ETR EXISTING TO REMAIN FCO FLOOR CLEANOUT FD FLOOR DRAIN GW GREASE WASTE NC NEW CONNECTION S SANITARY V VENT VTR CONNECTIONS INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL CONNECTION TO EACH PIECE OF EQUIPMENT. INSTALL DIELECTRIC COUPLINGS TO CONNECT PIPING MATERIALS OF DISSIMILAR METALS. SCREW JOINT STEEL PIPING UP TO AND INCLUDING 1-1/2". WELD PIPING USE NON-LEAD, NON-ANTIMONY SOLDER FOR SOLDERING DOMESTIC WATER COPPER PIPE. CLEANOUTS PROVIDE J.R. SMITH OR EQUIVALENT FLOOR AND WALL CLEANOUTS AS INDICATED ON THE DRAWINGS OR WHERE REQUIRED BY CODE IN ALL SOIL, WASTE, AND DRAIN LINES. IN AREAS WITH CERAMIC TILE OR CARPETED FLOORING, PROVIDE CLEANOUTS WITH SQUARE, ADJUSTABLE, NICKEL BRONZE TOP. IN AREAS WITH RESILIENT FLOORING, PROVIDE CLEANOUTS WITH SQUARE, ADJUSTABLE, NICKEL BRONZE TOP WITH TILE RECESS. CLEANOUTS SHALL BE SAME SIZE AS PIPE EXCEPT THAT CLEANOUTS LARGER THAN 4" WILL NOT BE REQUIRED. WHERE CLEANOUTS OCCUR IN WALLS OF FINISHED AREAS, THEY SHALL BE CONCEALED BEHIND CHROME PLATED ACCESS COVERS. RECOMMENDED FLOOR SINK LOCATION. VERIFY WITH ARCHITECT. IND INDIRECT WASTE DRAIN, HUB DRAIN, FLOOR DRAIN W/ FUNNEL OR SIMILAR. VERIFY WITH ARCHITECT FD FLUSH FLOOR DRAIN AND GRATE CONSTRUCTION AND BIDDING NOTES: THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL PLUMBING SYSTEM. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL AND EQUIPMENT RELATED TO THE INSTALLATION OF THE PLUMBING WORK. 2. THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE PLUMBING WORK. 3. 4. 5. 6. 7. EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ASME, ASTM, UL, NEMA, ANSI, ASHRAE, NFPA, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO POTBELLY. THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE PLUMBING WORK. THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY POTBELLY AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. THIS CONTRACTOR SHALL OBTAIN A COPY OF THE WORK LETTER FROM THE PSW CONSTRUCTION MANAGER PRIOR TO SUBMISSION OF THE BID. THIS CONTRACTOR SHALL SUBMIT SAID WORKLETTER AS EVIDENCE OF HAVING REVIEWED CONTRACTORS RESPONSIBILITIES WITHIN SCOPE OF WORK. ANY DISCREPANCIES BETWEEN THE WORKLETTER AND THE DESIGN DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE PSW CONSTRUCTION MANAGER, BEFORE BID DUE DATE. 8. PROVIDE AND INSTALL ALL "P" TRAPS, MANIFOLDS, DRAIN LINES, SHUT-OFFS, GREASE TRAPS & BACKFLOW PREVENTORS AS REQUIRED BY EQUIPMENT AND/OR LOCAL CODES. ALL KITCHEN, DINING ROOM AND BAR AREA WASTES ARE TO BE OPEN SITE IN FLOOR, UNLESS OTHERWISE SPECIFIED. 9. IF WATER PRESSURE AT EQUIPMENT AREA EXCEEDS 40 P.S.I. FLOW PRESSURE, INSTALL A PRESSURE REDUCING VALVE ON BOTH THE MAIN HOT AND COLD WATER SUPPLY LINES. 10. LOCATE AND FURNISH ALL AREA FLOOR DRAINS UNLESS OTHERWISE SPECIFIED. 11. PROVIDE AND SIZE ANY SOFTENING AND FILTERING EQUIPMENT THAT MAY BE REQUIRED UNLESS OTHERWISE SPECIFIED. 12. DETERMINE SIZE OF GAS SUPPLY LINE REQUIRED FOR ALL GAS EQUIPMENT INCLUDING FOOD SERVICE EQUIPMENT. 13. PLUMBER TO PROVIDE AND INSTALL BACKFLOW PREVENTORS ON ALL EQUIPMENT AS REQUIRED BY LOCAL CODE. 14. SEE EQUIPMENT SCHEDULE FOR LISTING OF ALL EQUIPMENT WITH APPOPRIATE SPECIFICATIONS. SCHEDULE WILL INCLUDE ALL RESPONSIBLITIES FOR PROVIDING AND INSTALLING EQUIPMENT. 15. THESE PLANS ARE FOR INFORMATION ONLY. INFORMATION ON THIS SHEET IS TO BE REVIEWED BY THE OWNER AND INCORPORATED INTO THE BUILDINGS' MECHANICAL PLANS IN ACCORDANCE WITH LOCAL CODES. THE ENTIRE INSTALLATION SHALL CONFORM WITH THE LATESET EDITION OF THE LOCAL AND STATE PLUMBING CODE IN ADDITION TO LANDLORD REQUIREMENTS AND SPECIFICATIONS. 16. THE OWNER SHOULD SUBMIT THESE PLANS TO LOCAL BUILDING, HEALTH AND FIRE DEPARTMENT OFFICIALS FOR APPROVAL. 17. CONTRACTORS TO MAKE USE OF ANY CONNECTIONS ALREADY INSTALLED IN EXISTING BUILDING WHENEVER POSSIBLE. 18. CONTRACTORS TO PROVIDE AND INSTALL WALL BACKING FOR WALL SHELVES. WALL MOUNTED HANDSINKS, WALL MOUNTED COOKING EQUIPMENT, ETC. VERIFY THESE LOCATION WITH OWNER. 19. FLOOR DRAINS AND/OR FLOOR SINKS SHOWN ARE RECOMMENDED LOCATIONS, MECHANICAL ENGINEER TO VERIFY CODE REQUIREMENTS PIPING VALVES: GENERAL PLUMBING CONTRACTOR TO PROVIDE VALVES WHERE INDICATED ON PLANS AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. PROVIDE BRAIDED STAINLESS STEEL HOSE (UNLESS OTHERWISE NOTED) BETWEEN VALVE AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. LOCATE SHUT-OFF VALVES ADJACENT TO EQUIPMENT FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT MOVING EQUIPMENT. PIPE SIZE INSULATION THICKNESS 1 LESS THAN OR EQUAL TO 12" 1" 2" DIA. OR GREATER 121" 2 (INSULATION VALUE = k VALUE NOT EXCEEDING .027 BTU PER INCH/h*ft *f SAFETY COVERS INSTALL SPECIFIED NO-SCALD SAFETY COVERS WITH INSULATED FOAM LINER AND TAMPER PROOF STRAP AT ALL EXPOSED PIPING. NOTE ALL PLANNING AND DESIGNING OF PLUMBING SYSTEMS SHALL BE PERFORMED ONLY BY LICENSED PLUMBERS OR A LICENSED DESIGN PROFESSIONAL. 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM VALVES PROVIDE VALVES FOR WORKING PRESSURE IN WATER PIPING OF 125 PSI OR GREATER. UNLESS NOTED OTHERWISE VALVES SHALL BE AS FOLLOWS: VALVE TYPE MANUFACTURER MODEL NO. CHECK VALVE (UP TO 2") NIBCO #S-22 FULL PORT BALL VALVE (UP TO 3") NIBCO #S-FP-600 GATE VALVE (UP TO 3") NIBCO #S-113 TEMP. AND PRESSURE RELIEF VALVE WILKINS #TP1100A WATER HAMMER ARRESTOR WILKINS #1250 BACKFLOW PREVENTER (WHOLE-HOUSE) WILKINS #950XLU BACKFLOW PREVENTER (SINGLE DEVICE) WILKINS #700 VACUUM RELIEF VALVE WILKINS #35VCH PRESSURE REDUCING VALVE WILKINS #500YSBR TRAP SEAL PRIMER JAY R. SMITH #2699-1 SUPPLY IF WATER PRESSURE SUPPLIED TO STORE IS GREATER THAN AND 65 PSI. THEN PROVIDE A PRESSURE REGULATOR TO MAIN SUPPLY TO MAINTAIN WATER PRESSURE. PROVIDE BACKFLOW PREVENTION ON WATER SERVICE IF REQUIRED BY LOCAL CODES. WATER PIPING PROVIDE THERMAL INSULATION ON ALL HOT TEMPERED & COLD WATER, AND HORIZONTAL WASTE PIPING IN CEILING SPACES, AND ON ALL COLD WATER PIPING IN CASEWORK AND BAR AREAS. USE SELF-SEALING CLOSED CELL FOAM OR JACKETED FIBERGLASS INSULATION WITH MANUFACTURE APPROVED ADHESIVES, SEALERS, AND COATINGS. ALL MATERIALS USED SHALL NOT EXCEED 25 FOR FLAME SPREAD, 50 FOR FUEL CONTRIBUTED, OR 50 FOR SMOKE DEVELOPED. UNLESS OTHERWISE REQUIRED BY THE LOCAL AUTHORITY OR ENERGY CODES, THE MINIMUM INSULATION LEVELS SHALL BE AS FOLLOWS: RAIN CONDUCTORS INSULATE RAIN WATER CONDUCTORS WHICH PASS THROUGH OCCUPIED AREAS WITH 21" THICK FIBERGLASS. KITCHEN EQUIPMENT ITEM NUMBERADDITIONAL INFORMATIONS 1. PIPING INSULATION: HVAC PIPING INSULATE REFRIGERANT SUCTION PIPING AND COOLING COIL CONDENSATE PIPING 34" THICK, SELF SEALING, CLOSED CELL FOAM. INSULATE HVAC HOT AND WITH CHILLED WATER PIPING SYSTEMS AND LOW PRESSURE STEAM AND CONDENSATE PIPING WITH 121" THICK, HEAVY DUTY, SELF SEALING, JACKETED FIBERGLASS. WASTE FS. TESTING ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY ARE BACKFILLED OR CONCEALED. AFTER TESTING IS COMPLETE, THE PLUMBING CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS REQUIRED BY LOCAL AUTHORITY. TEST WATER PURITY ACCORDING TO LOCAL REQUIREMENTS AND SUBMIT CERTIFIED TEST RESULTS TO ENGINEER FOR REVIEW AND APPROVAL. ICE BIN DRAIN INSULATE ICE BIN COPPER DRAIN LINES WITH 21" THICK, SELF-SEALING, SECTIONAL, CLOSED CELL FOAM. VENT THRU ROOF W INSTALLATION INSTALL EXPOSED PIPING FREE OF SAGS AND BENDS. PROVIDE BRACKET STANDOFFS FROM MOUNTING SURFACES SUFFICIENT TO ALLOW 1" CLEANING SPACE AROUND ALL PIPING, INCLUDING ANY ADDED PIPING INSULATION. INSTALL FITINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS. INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY WALLS, GYPSUM BOARD PARTITIONS, CONCRETE FLOOR AND ROOF SLABS. SEAL PIPE PENETRATIONS THROUGH RATED CONSTRUCTION WITH FIRESTOPPING SEALANT MATERIAL. UNDERGROUND WATER AND SEWER LINES SHALL BE LAID IN SEPARATE TRENCHES WITH A MINIMUM HORIZONTAL SPACING AS REQUIRED BY CODE, EXCAVATED TO THE PROPER DEPTH AND GRADED TO PRODUCE THE REQUIRED FALL. NATURAL GAS PIPING GAS PIPING SHALL BE SCHEDULE 40, SEAMLESS, BLACK STEEL PIPE. PROVIDE PIPING SUPPORT BLOCKING ON ROOF, COMPATIBLE WITH ROOFING SYSTEM. LINE SIZE BALANCING VALVE AFF PIPING (CONTINUED): A R 4 0 4 S. C H Wells S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. St. Louis - Montreal 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com mechanical electrical plumbing fire protection structural MISC. PLUMBING FIXTURES: GREASE INTERCEPTOR LANDLORD PROVIDED EXTERIOR GREASE INTERCEPTOR. PROJECT NUMBER: 16-059 PIPING: BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 PLUMBING SYMBOLS LEGEND ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 SHEET TITLE PLUMBING LEGEND AND NOTES SHEET NUMBER P1.0 GENERAL NOTES DESIGNATION EQUIPMENT DOMESTIC WATER GWH WATER HEATER MBH SUB-TOTAL PLUMING FIXTURE WATER FIXTURE UNITS TOTAL WATER FIXTURE UNITS 199 WATER CLOSET 10 2 20 199 LAVATORIES 2 2 4 RTU-1 ROOF TOP UNIT 250 HAND SINKS 2 2 4 RTU-2 ROOF TOP UNIT 250 MOP SINK 3 1 3 500 PREP SINK 3 1 3 SHAKE STATION 2 1 2 SODA SYSTEM/ICE MACHINE 1 1 1 3-COMPARTMENT SINK 3 1 3 BUILDING HEATING SUB-TOTAL TOTAL NATURAL GAS CONNECTED LOAD 699 MBH CAPACITY GAS METER REQUIREMENTS NUMBER OF FIXTURES TOTAL DEVELOPED LENGTH INCLUDING EQUIVALENT PIPE LENGTH FOR FITTING AND VALVE FRICTION LOSSES TO GAS METER. 75 FT X 1.2= 90 FT 6 14 DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. WATER PIPE SIZE= 2" 5 FIELD VERIFY ALL CONDITIONS PRIOR TO BIDDING AND START OF WORK. FIELD VERIFY ALL CONDITIONS 40 TOTAL WATER FIXTURE UNITS CONSULT GAS UTILITY COMPANY FOR REGULATOR RATING 2 B 9 7 13 2 1 WATER PIPING - POINT OF CONNECTION TO LANDLORD PROVIDED 2" CW TO SPACE. VERIFY EXACT LOCATION IN FIELD PRIOR TO WORK. CONTACT ENGINEER WITH ANY DISCREPANCIES. 2 EQUIPMENT WATER CONNECTIONS - PROVIDE AN RPZ OR BACKFLOW PREVENTION ON ALL DIRECT WATER SUPPLY LINES TO EQUIPMENT. 3 LAVATORY - 1/2" CW AND TW DOWN IN WALL TO LAVATORY. 4 WATER CLOSET - 1" CW DOWN IN WALL TO WATER CLOSET. PROVIDE WATER HAMMER ARRESTOR PRIOR TO FINAL CONNECTION (PDI TYPE "B"). 5 DIPPERWELL - 1/2" CW DOWN IN WALL TO DIPPERWELL. 15 BACKFLOW PREVENTOR - 1/2" CW DOWN IN WALL TO BACKFLOW PREVENTOR. BRANCH 1/2" CW TO ICE MACHINE, 1/4" CW TO TEA BREWER, AND BAG-N-BOX. 7 PREP SINK - 3/4" CW & HW DOWN IN WALL TO PREP SINK FAUCET. 8 3-COMPARTMENT SINK - 3/4" CW AND HW DOWN IN WALL TO 3-COMPARTMENT FAUCET. 9 SHAKE STATION & RINSER - 1/2" CW & HW DOWN IN WALL TO SHAKE STATION FAUCET. 10 BAG-N-BOX - 1/2" CW DOWN IN WALL TO BAG-N-BOX. 11 MOP SINK - 3/4" CW AND HW DOWN IN WALL TO MOP SINK FAUCET. 12 WATER HEATER - 1" CW DOWN AND 1" 140° HW UP FROM WATER HEATER MOUNTED ON WATER HEATER STAND. 13 HAND SINK - 1/2" CW AND TW DOWN IN WALL TO HAND SINK. 14 TEA BREWER - 1/4" CW DOWN IN WALL TO TEA BREWER. 15 DO NOT ROUTE ANY WATER PIPING OVER ELECTRICAL PANELS OR TRANSFORMERS. 16 ROUTE LOW PRESSURE GAS PIPING DOWN THROUGH ROOF TO CONNECT TO GAS WATER HEATER. PROVIDE 6" DIRTLEG AND SHUTOFF PLUG VALVE PRIOR TO FINAL CONNECTION. VERIFY SIZE AND LOCATION IN FIELD. 17 ROUTE GAS TO NEW TENANT PROVIDED GAS METER. NEW METER'S DEMAND= 699 CFH, (FIELD VERIFY ACTUAL LOCATION) CONTRACTOR TO TENANT PROVIDED METER. DELIVERY PRESSURE: 7 IN W.C. APPROXIMATE LENGTH TO METER BANK 90'-0". CONTRACTOR TO VERIFY EXACT LENGTH AND LOCATION IN FIELD. VERIFY METER REQUIREMENTS WITH GAS COMPANY PRIOR TO WORK. 18 PROVIDE RECIRCULATING PUMP. BELL AND GOSETT NRF-22. 115V, 2940 RPM. PROVIDE WITH AQUASTAT. 19 CONTRACTOR PROVIDED RPZ - 1-1/2" CW DOWN IN WALL TO REDUCED PRESSURE ZONE BACKFLOW PREVENTOR (WATTS LF919QT OR EQUAL) AND TENANT PROVIDED WATER SUBMETER MOUNTED ON WALL. 20 CONDENSATE DRAIN DOWN FROM COOLER, FREEZER AND/ OR RTU'S DOWN INTERIOR WALL, DRAIN INDIRECTLY TO FLOOR DRAIN. 21 1" CONDENSATE DOWN FROM ROOFTOP UNITS ABOVE CEILING AND ROUTED AS HIGH AS POSSIBLE AS SHOWN. 22 ROUTE LOW PRESSURE GAS PIPING ON ROOF AS REQUIRED TO CONNECT TO GAS FIRED RTU'S. PROVIDE 6" DIRT LEG AND SHUT OFF PLUG VALVE PRIOR TO FINAL CONNECTION. 23 CONDENSATE DRAIN PIPING IN FREEZER, PROVIDE TYPE "L" COPPER CONDENSATE DRAIN PIPING WITH 1-1/2" THICK FIBERGLASS INSULATION OVER ELECTRICAL HEAT TRACE (SUPPLIED AND INSTALLED BY ELECTRICAL CONTRACTOR) SEE ELECTRICAL DRAWINGS. PVC CONDENSATE DRAINS INSIDE COOLERS, FROM EVAPORATOR COILS, SLOPE 2% AND HOLD TIGHT TO COOLER WALL. ALL SURFACE MOUNTED PIPING SHALL BE INSTALLED ON 1" SPACER TO ALLOW FOR CLEANING. 20 3 21 22 23 22 1 4 4 12 11 R 4 0 4 S. 6 17 6 10 A C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 S 0334 St. Louis - Montreal 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com mechanical electrical plumbing fire protection structural ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 19 18 R THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. W.H. 23 E 955 ILLINOIS DESIGN FIRM # 184.006688 8 13 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM PROJECT NUMBER: 16-059 SYSTEM A REFER TO SCHEDULES, DETAILS AND RISER DIAGRAMS FOR MORE INFORMATION ON SIZING OF PIPING TO EQUIPMENT. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 TABLE TO CALCULATE WATER FIXTURE UNITS GAS LOAD SUMMARY KEYNOTES 16 SHEET TITLE PLUMBING SUPPLY & SCHEDULES SHEET NUMBER P2.0 PLUMBING GENERAL NOTES: NUMBER OF FIXTURES POINT OF CONNECTION TO EXISTING SANITARY WASTE PIPING. VERIFY EXACT SIZE, INVERT ELEVATION AND LOCATION IN FIELD PRIOR TO WORK. CONTACT ENGINEER IF ANY DISCREPANCIES ARE DISCOVERED. 2 2" WASTE DN AND 2" VENT UP IN WALL FROM SINK OR LAVATORY D P.C. TO VERIFY LOCATIONS OF SODA EQUIPMENT WITH VENDOR AND/OR OWNER. ADJUST PLUMBING LOCATIONS AS NECESSARY. 3 3" WASTE DN AND 2" VENT UP IN WALL FROM FLOOR DRAIN/SINK. 4 4" WASTE DN AND 2" VENT UP IN WALL FROM WATER CLOSET. 5 3" WASTE DN AND 2" VENT UP IN WALL FROM MOP SINK 6 INDIRECT WASTE WITH 2" GAP FROM 3 COMPARTMENT SINK TO FLOOR SINK. 7 INDIRECT WASTE WITH 2" GAP FROM PREP SINK TO FLOOR SINK 8 INDIRECT WASTE WITH 2" GAP FROM DIPPERWELL AND SINK TO FLOOR SINK 9 INDIRECT WASTE WITH 2" GAP FROM ICE MACHINE AND/OR TEA BREWER TO FLOOR SINK/ DRAIN. B FIELD VERIFY ALL CONDITIONS PRIOR TO BIDDING AND START OF WORK. TOTAL DRAINAGE FIXTURE UNITS C VERIFY LOCAL PLUMBING AND HEALTH DEPT. DRAIN REQUIREMENTS FOR THE 3-COMPARTMENT SINK, PREP SINK, AND SHAKE SINK. WATER CLOSET 10 2 20 LAVATORIES 2 2 4 HAND SINKS 2 2 4 FLOOR DRAINS 3 6 18 FLOOR SINKS 5 4 20 E G.C. TO PROVIDE ACCESS FOR SODA LINES IF NECESSARY. COORDINATE WITH VENDOR AND/OR OWNER. MOP SINK 3 1 3 F. ALL FLOOR DRAINS TO INCLUDE TRAP PRIMERS WITH BACKFLOW PREVENTER. TOTAL DRAINAGE UNITS = 69 FIELD VERIFY ALL CONDITIONS A DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. NOTE: THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 3 3 8 2 3 7 2 3 6 13 10 9 11 10 3 12 1 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM 14 2 R 4 0 4 S. 10 3" WASTE DOWN FROM FLOOR DRAIN/ FLOOR SINK. 11 ROUTE TO CONNECT TO EXISTING LANDLORD PROVIDED EXTERIOR GREASE INTERCEPTOR. VERIFY EXACT INSTALLATION REQUIREMENTS WITH MANUFACTURER IN FIELD PRIOR TO ANY WORK. 12 CONDENSATE FROM COOLER, FREEZER AND RTU'S TO DISCHARGE INDIRECTLY INTO FLOOR DRAIN AT A SLOPE NOT LESS THAN 1/8" PER FOOT. PROVIDE MINIMUM 1" AIR GAP FROM LIP OF BASIN. PROVIDE WITH 7" FUNNEL. 13 FLOOR SINK AT 3-COMP SINK TO ALIGN WITH RIGHT SIDE BASIN. SEE DETAIL 03/P6.0. 14 POINT OF CONNECTION TO EXISTING VENT PIPING. C Wells H I S t ., T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 E 955 R ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. St. Louis - Montreal 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com mechanical electrical plumbing fire protection structural ISSUE DATE 1 ISSUE DD SET 95% SET 3 4 4 3 S 0334 PROJECT NUMBER: 16-059 DRAINAGE FIXTURE UNITS 1 BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 A REFER TO SCHEDULES, DETAILS AND RISER DIAGRAMS FOR MORE INFORMATION ON SIZING OF PIPING TO EQUIPMENT. TABLE TO CALCULATE DRAINAGE FIXTURE UNITS PLUMING FIXTURE KEYNOTES: DATE 04-26-2016 05-23-2016 1 W.H. 10 5 SHEET TITLE PLUMBING WASTE PLAN SHEET NUMBER P3.0 DESCRIPTION MANUFACTURER MODEL # Count FINISH FURN. INSTALL P102 WATER CLOSET-FLO WISE WITH AUTOMATIC FLUSH AMERICAN STANDARD MADERA FLOWISE 3249.001, ELOGATED BOWL; PROVIDE 6067 HARD WIRED SELECTRONIC FLUSH VALVE (P104) 2 WHITE GC GC P201 THREE COMPARTMENT SINK ELKAY 3C16X20 - 2 - 18X, 20"D X 88"L, 10"H REAR SPLASH, LEFT & RT HAND 18" DRAINBOARDS 1 SS VD GC P204 STAINLESS STEEL WORKTABLE W/ SINK - PREP TABLE ELKAY SLWT30X84BS 1 SS VD P205 MOP SINK W/ FAUCET FIAT MOLDED STONE INTEGRAL DRAIN MSBID2424 W/ 830AA SERVICE FAUCET 1 WHITE P206 FLOOR SINK SIOUX MANUFACTURING 861-23X W/ HALF GRATE 861-52i P208 FLOOR DRAIN SIOUX MANUFACTURING P210 WALL-HUNG LAVATORY AMERICAN STANDARD VOLTS PLUMBING SCHEDULE WATTS AMP PLUG HW. SUPPLY CW. SUPPLY TW. SUPPLY WASTE VENT PROVIDE WITH 5905.100 HEAVY DUTY AMERICAN STANDARD SEAT, FLUSH VALVE #6065.121.002 PROVIDE JBOX IN WALL WITH LOW VOLTAGE POWER. 1" 4" 3/4" 3/4" (3) 2" INDIRECT WASTE, SEE ITEM #P600 FOR FAUCET GC 3/4" 3/4" 1-1/2" PROVIDE FLOOR SINK W/ INDIRECT WASTE CONNECTION. SEE ITEM #P601 FOR FAUCET GC GC 1/2" 1/2" 3" 2" 4 GC GC 3" 2" 842-3-P-NQ 6 GC GC 3" 2" LUCERNE 0355.012 2 VD GC WHITE 2" COMMENTS 1/2" 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM VACUUM BREAKER PROVIDE DEEP SEAL TRAPS, ADD VEGETABLE OR MINERAL OIL TO TRAP SEE ITEM #P611 FOR FAUCET. PROVIDE TEMPERING VALVE. A R 4 0 4 S. HAND SINK ELKAY SEHS-17X - 17"L X 15"W X 5"D W/ SIDE SPLASHES 2 P215 SHAKE STATION (RIGHT HAND VERSION) ELKAY CUSTOM BACK BEVERAGE COUNTER P401 CHEMICAL DISPENSER CHEMICAL DISPENSER P405 HOSE BIB P406 SS VD GC 1/2" 1 VD VD 1/2" PROVIDE TEMPERING VALVE 1629WML/1629WMR 2 VD VD 1/2" CONTAINS ALUMINUM CLORIDE. PROVIDE STAINLESS STEEL DOUBLE CHECK BACKFLOW PREVENTOR WOODFORD MODEL 17CC 1 GC GC ANTI-SIPHON FREEZLESS TEMPERING VALVE LEONARD 220 4 GC GC PROVIDE AT EACH HAND SINK AND LAVATORY, SET TO 100° F P408 BUILT-IN DIPPERWELL T&S BRASS 006678-45 W/ B2282-F03 1 SS VD VD P409 RINSER BLENDTEC JRE-610 LITTLE BLACK RINSER 1 SS VD VD P410 TEA BREWER BUNN TB3Q 1 VD VD P600 3 COMP SINK FAUCET T&S BRASS B-0230-LN FAUCET; 064X 16" SWING NOZZLE W/ STREAM REGULATOR 1 VD GC 1/2" 1/2" P601 PREP TABLE SINK FAUCET T&S BRASS B-0225-LN FAUCET; 135X 12" SWIVEL GOOSENECK 1 VD GC 1/2" 1/2" P603 HAND SINK FAUCET T&S BRASS B-1115-LN FAUCET; 131X SWING GOOSENECK; 1136-45 TEFLON SEAT WASHERS 2 BRONZE VD GC 1/2" 1/2" P605 SPRAYER NOZZLE T&S BRASS B-0133 W/ 063X, B-0155-LNEZ & B-0970-FEZ 1 CHROME VD GC 1/2" P610 SHAKE STATION FAUCET & TEMPERING VALVE T&S BRASS B-0306 1 CHROME VD VD 1/2" P611B LEVER LAVATORY FAUCET-4" SPREAD MOEN 8413SP 2 CHROME VD VD 1/2" P702 WALK-IN COOLER/FREEZER - END DOOR KOLPAK CUSTOM 1 VD GC P704 SODA/ICE DISPENSER CORNELIUS IDC255 1 VD VD 120/60 9.3 3/8" 3/4" P707 ICE MAKER AT SODA MACHINE- AIR-COOLED HOSHIZAKI AMERICA, INC. KML-451MAH 1 VD VD 115/60/1 10.3 1/2" 3/4" P715 COOLER REFRIGERATION SYSTEM - REMOTE COOLER KOLPAK POLAR PAK 1 VD GC 208-230/60/1 ALLOWS CONDENSOR TO BE LOCATED ON THE ROOF OR OUTSIDE TO REDUCE HEAT INSIDE STORE; REFRIGERATION HOOK-UP BY EQUIPMENT VENDOR P716 COOLER REFRIGERATION SYSTEM - REMOTE FREEZER KOLPAK POLAR PAK 1 VD GC 208-230/60/1 ALLOWS CONDENSOR TO BE LOCATED ON THE ROOF OR OUTSIDE TO REDUCE HEAT INSIDE STORE; REFRIGERATION HOOK-UP BY EQUIPMENT VENDOR P800 GAS WATER HEATER BRADFORD WHITE OR EQUAL EF-60T-199 1 GC GC 120/1 P804 ICE MAKER CONNECTION HOSE DORMONT MANUFACTURING W37B2Q48 1 VD GC P805 LEVER TWIST WASTES T&S BRASS B-3950 2 VD GC P807 WATER HEATER STAND NATIONAL HOT WATER PK101 1 GC GC SS 1/2" 1/2" 1-1/2" 1 1/2" 1-1/2" SEE ITEM #P603 FOR FAUCET. PROVIDE TEMPERING VALVE. FAUCET INCLUDED H S t ., I T E Suite 300 C T S Chicago, + IL P L A 60607 N N P: 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. St. Louis - Montreal 120/1/60 1780 14.8 NEMA 5-1SP 1/4" 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com PROVIDE TEMPERING VALVE 8" WALL MOUNT FAUCET, ADD-ON FAUCET W/ 8" SWING NOZZLE, CERAMIC CARTRIDGES, COMPACT SPRING & FLEX HOSE, B-0107-C SPRAY VALVE, VACUUM BREAKER & 6" WALL BRACKET & LEVER HANDLES USE FOR NEW STORES 1/2" REFRIGERATION HOOK-UP BY EQUIPMENT VENDOR 1.8 1" mechanical electrical plumbing fire protection structural 1" STANDARD AIR COOLED UNIT REFER TO INSTALLATION GUIDE FOR MORE INFORMATION, EXPANSION TANK TO BE PROVIDED. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 P211 C Wells PROJECT NUMBER: 16-059 ITEM # ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 SHEET TITLE PLUMBING SCHEDULE SHEET NUMBER P4.0 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A R 4 0 4 S. C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. St. Louis - Montreal 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com PROJECT NUMBER: 16-059 BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 mechanical electrical plumbing fire protection structural ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 SHEET TITLE PLUMBING RISERS SHEET NUMBER P5.0 HOT WATER RETURN TO WATER HEATER. COLD WATER SUPPLY TO WATER HEATER. HOT WATER TO FIXTURES AS SHOWN ON PLANS PROVIDE FULL PORT BALL SHUT-OFF VALVES PROVIDE PIPE UNIONS, DIELECTRIC IF REQUIRED FOR DISSIMILAR METALS. DRAIN LINE RESTROOM LAVATORY MOUNT 1" ABOVE FLOOR FINISHED FLOOR (SEE ARCHITECTURAL FOR FLOOR SLOPES) AIR GAP = 2 X "d" STOP VALVE TURN TRAP PRIMER DRAIN LINE INTO WALL TYPE 'K' COPPER TUBING - NO JOINTS BELOW FLOOR SILICONE BEAD BOLT STRAPS TO SOLID BLOCKING IN WALL WITH 3/8"Ø X 2-1/2" LAG BOLTS, TYPICAL OF FOUR (4) 1/2" DIAMETER THINWALL (EMT) CONDUIT WITH ENDS FLATTENED TRAP PRIMER WITH CHROME FINISH PPP#PROI-ULP500 WITH DU-4 COLD WATER 3/4" x 24 GUAGE PERFORATED PLUMBERS TAPE GAS-FIRED WATER HEATER PER SPECS AND SCHEDULE. PROVIDE A 210° F ASME APPROVED TEMPERATURE AND 150 PSI PRESSURE RELIEF VALVE WITH TEST LEVER, SIZED WITH CAPACITY PER WATER HEATER MANUFACTURER'S RECOMMENDATIONS. G WH PROVIDE A HARD COPPER RELIEF VALVE DISCHARGE LINE FULL SIZE OF VALVE OUTLET TO END OVER JS WITH 6" AIR GAP. BURNER THERMOSTAT AND PRESSURE REGULATOR FURNISHED WITH WATER HEATER. SET WH ON PLATFORM (PLATFORM BY OTHERS) ROUTE P&T VALVE TO TERMINATE INTO MOP SINK Scale: N.T.S. 7 8" MINIMUM, 24" MAXIMUM HIGH STRAINER POSTION FLR DRAIN SET BELOW TOP OF FIN FLR. ADJACENT TILE CANTS TO CREATE DIMPLE 3/4" x 24 GUAGE PERFORATED PLUMBERS TAPE 12 THIN SET CERAMIC TILE, TYP UNION CLEANOUT PLUG AND BODY. SEE SPECS. MOISTURE BARRIER 11 4" T S Chicago, + IL P L A 60607 N N P: 312 E 955 R BALL VALVE BALL VALVE CHECK VALVE RISER STRAINER 1/8 BEND FULL SIZE, 4" MAX. FLEXIBLE CONNECTION 2 REQUIRED mechanical electrical plumbing fire protection structural Scale: N.T.S. BELL & GOSSETT NRF-22 PLUG IF END OF LINE FLOW 4" ISSUE DATE 2 FLOOR DRAIN Scale: N.T.S. 5 FLOOR CLEANOUT Scale: N.T.S. 8 CIRCULATING PUMP DETAIL Scale: N.T.S. 10 NOT USED Scale: N.T.S. 13 NOT USED Scale: N.T.S. ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 3-COMPARTMENT POT SINK 2"OUTLET (TYPICAL) 3" CO. FLOOR SINK 3" 4" SHEET TITLE PLUMBING DETAILS POINT OF CONNETION TO EXISTING GREASE WASTE. VERIFY IN FIELD. EXISTING EXTERIOR LANDLORD PROVIDED GREASE INTERCEPTOR SHEET NUMBER VERIFY EXACT EXTERIOR LOCATION IN FIELD 3 3 COMPARTMENT SINK WITH GREASE INTERCEPTOR Scale: N.T.S. S 0334 NOT USED WIRING BY ELECT. CONTRACTOR ADJUSTING COLLAR C 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com Scale: N.T.S. FIN. FLOOR 5" SQ E 300 2'-6" MAX. WATER HEATER CAULK JOINT 8-3/8" T Suite St. Louis - Montreal COVER LOW STRAINER POSITION I S t ., BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 Scale: N.T.S. H 1/2" DIAMETER THINWALL (EMT) CONDUIT WITH ENDS FLATTENED PIPING SHOWN IS SCHEMATIC. PROVIDE CLEARANCES RECOMMENDED BY MANUF., SEISMIC STRAPPING. SET THERMOSTAT AT 140°F. TRAP PRIMER DETAIL C Wells THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. DRAIN VALVE BY HEATER MANUFACTURER 6" LONG DIRT LEG PROVIDE WATER- TIGHT GALVANIZED SHEET METAL PAN 2" DEEP WITH 1" DRAIN PIPE TO JS PIPE 4 R 4 0 4 S. ILLINOIS DESIGN FIRM # 184.006688 GAS SHUT-OFF COCK WITH LEVER HANDLE & GROUND JOINT UNION FLOOR DRAIN WITH TRAP PRIMER CONNECTION FLOOR SINK A 4" PVC EXHAUST LIFT OUT ALUMINUM SEDIMENT BUCKET 1 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM 4" PVC AIR INLET PROJECT NUMBER: 16-059 "d" FLOOR GRATE RECIRCULATING PUMP THERMOMETER NOTE: ALL EXPOSED PIPING SHALL BE CHROME PLATED "d" EXPANSION TANK 9 NOT USED Scale: N.T.S. 11 NOT USED Scale: N.T.S. 14 NOT USED Scale: N.T.S. P6.0 DESCRIPTION VAC/PH LOAD HAFF 24HR. REMARKS CIRCUIT(S) E103 COOLER LIGHTS AND SWITCH 120/1 1.6 A 78 in. X A,J,K,R RP-34 E103A DOOR HEATER 120/1 1.47 A 72 in. X A,K RP-12 E105 REFRIGERATED FRONT LOAD STATION 120/1 8.6 A 18 in. X D,H LP-2 E106 REFRIGERATED DRESS STATIONS -(FRONT) 120/1 4.9 A EA. 18 in. X D,H LP-6 & LP-8 E106 REFRIGERATED DRESS STATIONS - (BACK) 120/1 4.9 A EA. 44 in. X D,H LP-16 E107 REFRIGERATE SALAD STATION - (FRONT) 120/1 5.5 A 18 in. X D,H LP-10 E107 REFRIGERATE SALAD STATION - (BACK) 120/1 5.5 A 44 in. X D,H LP-14 E128 ICE CREAM DIPPING CABINET 120/1 8.0 A 44 in. X D, H RP-37 E130 UNDER COUNTER REFRIGERATOR (SHAKE STATION) 120/1 3.9 A 18 in. X D,H LP-26 E131 FUTURE EQUIPMENT 120/1 1 A 44 in. X D,H LP-7 E302 MEATBALL WARMER 120/1 13.3 A 18 in. D,H RP-15 E302A SOUP WARMER 120/1 13.3 A D,H LP-12 E304 CONVEYOR OVEN 208/3 40.0 A E401 SLICER 120/1 7.0 A 45 in. D,H RP-25 E404 FAX MACHINE 120/1 4.0 A 44 in. D,E,H LP-28 E406 P.O.S EQUIPMENT 120/1 2.0 A EA. E,F,H,T LP-1 E427 BLENDER 120/1 15.0 A EA. 18 in. D,H LP-33 & LP-35 E408 FUTURE EQUIPMENT (BRISKER) 120/1 5.0 A 74 in. D,H LP-20 E409A CARBONATORS 120/1 4.0 A 91 in. D,E,H RP-32 M109 FUTURE EQUIPMENT 120/1 15.0 P102 AUTOMATIC FLUSH VALVE 120/1 X P410 TEA BREWER 120/1 14.0 A 18 in. D,H RP-24 P704 SODA/ICE DISPENSERS 120/1 9.3 A 18 in. D,E,H LP-18 P707 ICE MAKER 120/1 19.9 A 24 in. P715 REMOTE COOLER CONDENSER 208/230/1 7.4 A P715 REMOTE COOLER BLOWER 115/1 1.8 A A,T,S JBOX @ 23"CL IN DIEWALL 45 A EA. A in. REFER TO CUT SHEET P716 REMOTE FREEZER CONDENSER 208/230/1 12.6 A P716 REMOTE FREEZER BLOWER 208/230/1 5.7 A P800 GAS WATER HEATER 120/1 1.8 A P410 18 in. SEE DETAIL 7/E7.0 ON ROOF ON ROOF 100 P704 E130 P707 E131 in. D RP-22 RP-40 X C,D,E,H LP-29,31 X C LP-22,24 X C LP-30 X C RP-28,30 X C RP-39,41 X C,E FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. 1 ELECTRICAL EQUIPMENT: SEE RISER DIAGRAM AND SCHEDULES, SHEET E6.0 & E7.0. A. WIRE TO JUNCTION BOX ON EQUIPMENT. B. ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. HVAC EQUIPMENT: SEE ELECTRICAL CONNECTION SCHEDULE, SHEET E6.0. B. ATTACH RECEPTACLE OR J.B. TO COUNTER OR EQUIPMENT. 2 C. WIRE TO EQUIPMENT. PROVIDE DISCONNECT OR CORD AND PLUG AS REQUIRED BY LOCAL CODE. D. PROVIDE RECEPTACLE FLUSH IN WALL. E. EQUIPMENT NOT SUPPLIED BY K.E.C., VERIFY REQUIREMENTS WITH SUPPLIER. F. DEDICATED CIRCUIT/ISOLATED GROUND, PROVIDE ELECTRICAL OUTLET. PROVIDE CONDUIT ACCESS FOR COMMUNICATION CABLE, G. VERIFY WITH OWNER. PROVIDE AND INSTALL CORD & PLUG AND RECEPTACLE. H. EQUIPMENT SUPPLIED WITH CORD & PLUG. C. D. REFER TO DETAIL SHEETS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL DEVICES. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING ALL VOLTAGE REQUIREMENTS ON ALL EQUIPMENT. HVAC RECEPTACLE: PROVIDE RECEPTACLE MOUNTED ADJACENT TO EQUIPMENT. CONNECT TO CIRCUIT RP-2. 5 RECIRCULATION PUMP PROVIDE 20A, 120V OUTLET FOR RECIRCULATION PUMP, COMPLETE ALL FINAL ELECTRICAL CONNECTIONS. 6 MANAGER'S DESK: SEE DETAIL 3/E7.0 FOR ALL OUTLET AND CIRCUITING REQUIREMENTS. ELECTRICAL CONTRACTOR TO VERIFY LOCATIONS OF SODA EQUIPMENT WITH OWNER AND/OR SODA VENDOR. ADJUST ELECTRICAL LOC. AS NECESSARY. 7 FLY LIGHT PROVIDE AND OUTLET AT 9'-0" AFF FOR THE FLY LIGHT. I. ALL KITCHEN 125 VOLT, SINGLE PHASE, 15 AND 20 AMP RECEPTACLES SHALL BE GFCI TYPE PER NEC SECTION 210.8 (B).F. 8 SHOW WINDOW RECEPTACLES PROVIDE DUPLEX RECEPTACLE MOUNTED ABOVE WINDOW FOR SHOW WINDOW REQUIREMENTS, AS REQUIRED BY THE NEC J. ALL GFCI RECEPTACLES SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION OR A GFCI CIRCUIT BREAKER SHALL USED TO FEED THE CIRCUIT NOTED. 9 FUTURE IT EQUIPMENT INSTALL DUPLEX AT MILLWORK WALL AT 18" AFF ELECTRICAL CONTRACTOR SHALL COORDINATE WITH PLUMBING AND HVAC CONTRACTORS FOR ANY ADDITIONAL EQUIPMENT NEEDING POWER. F. ALL FUTURE EQUIPMENT NEEDED HEREIN SHALL BE PROVIDED WITH AN APPROPRIATE RECEPTACLE AND FULLY WIRED. EVEN IF NOT SPECIFICALLY INDICATED. GFCI BREAKERS (NOT RECEPTACLES) SHALL BE UTILIZED FOR ALL G. 125V, 15A AND 20A CIRCUITS TO KITCHEN EQUIPMENT AND FLOOR BOXES. PROVIDE DEDICATED NEUTRAL WIRE FOR ALL OF THESE CIRCUITS. H. 3'-3" 2'-0" E408 E427 OUTLET ABOVE IN CABINET 1'-4" RP-8 4 FROM CEILING. N. WIRE FROM J.BOX TO EQUIPMENT. INSTALL REMOTE CONTROLS SUPPLIED WITH EQUIPMENT. Q. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 13 INTERIOR ILLUMINATED SIGNAGE: PROVIDE CONTACTOR FOR CIRCUIT, CIRCUIT TO BE CONTROLLED WITH INTERIOR LIGHTING. COORDINATE EXACT LOCATION OF OUTLET WITH MILLWORK. OUTLET TO BE LOCATED BEHIND WALL CABINET DOOR. R. E.C. TO USE #8 WIRE AND 50 AMP CIRCUIT BREAKER. 14 FUTURE POS STATION INSTALL DUPLEX AT BACKLINE WALL AT 44" AFF. S. 50 AMP CORD, PLUG, PIN, AND SLEEVE RECEPTACLE WITH BACK BOX PROVIDED BY K.E.C., INSTALLED BY E.C. T. SURFACE MOUNT RECEPTACLE IN BOTTOM OF CABINET U. FOUR WIRE CONNECTION. UNIT PROVIDED WITH CORD AND PLUG, INSTALLED BY E.C. V. WIRE DEFROST TIMER TO BLOWER COIL. PROVIDED BY K.E.C., INSTALLED BY E.C. W. STUB OUT MILLWORK WALL AND INSTALL OUTLET IN RECESS ON LEFT SIDE OF ICE CREAM UNIT. X. WIRE DEFROST TIMER TO BLOWER COIL. PROVIDED BY K.E.C. INSTALLED BY E.C. 03 M109 E409 E7.0 6 E401 12'-4" 1 CEILING MOUNTED 45 KVA TRANSFORMERS 4 E304 S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 P102 7'-0" 8'-0" 12'-2" 16'-4" 19'-0" E103 11 11 P102 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com mechanical electrical plumbing fire protection structural DATE 04-26-2016 05-23-2016 RP-4 RP-4 7 RP-13 +42" AFF S W.H. J P800 5 3 RP-21 +90" AFF 13 S216A +36" AFF LP-39 10 S J +42" AFF RP-26 8 RP-8 +42" AFF RP-13 +42" AFF RP-26 +42" AFF RP-26 8 RP-8 S 0334 St. Louis - Montreal 2 P716 8 RP-8 R THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. 21'-10" 25'-8" RP-26 +42" AFF E 955 ILLINOIS DESIGN FIRM # 184.006688 ISSUE DD SET 95% SET J P715 E107 H ISSUE DATE J E406 C Wells 2 2 E105 E302 8 RP-8 M. 12 12 9 FROM FLOOR. OVEN OUTLET GC TO PROVIDE LEVITON 8450 RECEPTACLE AT OVEN OUTLET (1 PER OVEN). CORD & PLUG TO BE SUPPLIED BY VENDOR. 4'-10" 2 L. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. E106 E106 CONNECTION INSIDE WALK-IN, FROM CEILING. INSTALL EXTRA LIGHT SHIPPED LOOSE WITH EQUIPMENT. WIRE TO SWITCH ON WALK-IN, RUN CONDUIT ABOVE WALK-IN. CAULK ALL PENETRATIONS AROUND CONDUIT INSIDE AND OUTSIDE OF WALK-IN. RP-10 E107 K. P. E404 E302A WIRE FROM SWITCH IN WALK-IN PANEL TO LIGHTS IN GLASS DOOR. 11 6" 8 J. PROVIDE AND INSTALL WALL SWITCH TO OPERATE REMOTE COMPRESSOR. 2'-7" 8 3/4" 1'-9 1/2" WIRE FROM CONTROL PANEL TO FAN(S) ON EXTERIOR ROOF. PROVIDE AND INSTALL DISCONNECT & SWITCH. LOCATE SWITCH PER PLAN. O. 19'-6" 18'-0" 15'-11" 10'-7" 7'-0" 3'-2 1/2" 14 I. AUTOMATIC PLUMBING FIXTURES PROVIDE J-BOX/OUTLET FOR POWER AT TOILET FLUSH VALVE DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. R 4 0 4 S. MUSICIAN'S AREA QUAD & KILL SWITCH TIED TO MUSIC SYSTEM AT MANAGER'S DESK. KILL SWITCH TO TURN ON/OFF SPEAKERS ONLY. MOUNT AT 3'-0" TO CENTER OF BOX FIELD VERIFY ALL CONDITIONS: 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM A 10 E128 10" 1'-0" 3 WATER HEATER: PROVIDE DISCONNECT SWITCH AND FEEDER ADJACENT TO WATER HEATER. SEE ELECTRICAL CONNECTION SCHEDULE, SHEET E6.0. 4 E. RP-14,16,18 RP-31,33,35 C,E A. PROJECT NUMBER: 16-059 NO. ELECTRICAL SCHEDULE REMARKS: KEYNOTES: BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 GENERAL NOTES: ELECTRICAL SCHEDULE SHEET TITLE POWER PLAN SHEET NUMBER E2.0 COORDINATE THE EXACT LOCATION AND MOUNTING HEIGHTS FOR ALL THE LIGHT FIXTURES WITH THE REFLECTED CEILING PLAN WITHIN THE ARCHITECTURAL SET B. LIGHT FIXTURES ARE FURNISHED BY THE OWNER, INSTALLED BY THE GENERAL CONTRACTOR, AND WIRED BY THE ELECTRICAL CONTRACTOR, U.N.O. REFER TO LIGHTING SCHEDULE SHEET E5.0. C. D. REFER TO ARCHITECTURAL CASEWORK DETAILS FOR EXACT LOCATIONS OF LIGHT FIXTURES LOCATED IN CASEWORK. E. ALL OUTLETS/SWITCHES IN THE PREP ROOM, SERVICE LINE AND TOILET ROOMS SHALL BE WHITE WITH WHITE COVERPLATES AND BROWN WITH BROWN COVERPLATES ELSEWHERE. THIS IS TO INCLUDE ALL SOUND SYSTEM AND PHONE/ FAX COVERS. L500 SEE SHEET E5.0 FOR COMPLETE LIGHTING SCHEDULE G. ALL LIGHTING FIXTURES ON THIS SHEET SHALL BE CIRCUITED TO PANEL "LP". UNLESS OTHERWISE NOTED. 4 CONTRACTOR TO FIELD VERIFY ALL EXTERIOR LANDING LIGHTS ARE ARE ON A BACK-UP POWER SUPPLY PER IBC SECTION 1006.3. ALL LIGHTING IN KITCHEN/PREP AND BEVERAGE AREAS SHALL HAVE PROTECTIVE SHIELDING. L207 L613 L615 L208 L615 L615 LP-9g LP-9g LP-9g L102 L102 L102 2 LP-5f LP-9e LP-9e L310 L310 LP-9g L302 RP-34 LP-11 L615 9 9 LP-13c LP-13c L400 2 L400 L104 LP-11 LP-11 TIME CLOCK LOCATE TIME CLOCK AND CONTACTORS NEAR ELECTRICAL PANELS. 9 PROVIDE CURRENT LIMITING DEVICE REFER TO LIGHTING FIXTURE SCHEDULE (ON SHEET E5.0-L620) 10 EMERGENCY EGRESS LIGHTING PROVIDE IF NOT EXISTING (2) LAMP BATTERY BACKUP EGRESS LIGHTING FIXTURE. CIRCUIT AS INDICATED. 11 INTERIOR SIGN POWER PROVIDE J-BOX, DISCONNECT, AND FINAL CONNECTIONS FOR THE SIGN. THE SIGN IS SUPPLIED BY OTHERS. FIELD VERIFY THE EXACT LOCATION AND REQUIREMENTS. VERIFY LOCATION W/ PSW PRIOR TO INSTALL. SIGNAGE PERMIT BY OTHERS. REFER TO POWER PLAN FOR CIRCUITING. R C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 6 S203 R THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. St. Louis - Montreal 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com mechanical electrical plumbing fire protection structural SM L615 L502 2 2 L500 LP-3 L207 LP-11 L200 LP-13b LP-11 LP-13a L102 LP-13a L100 L100 LP-13 2 L500 L100 S100 LP-19 L502 10 2 LP-13a L615 L208 2 LP-5f LP-13a L208 L100 L615 S100 L305 2 L502 LP-15 LP-11 LP-13 LP-13 LP-13a 3 2 LP-13b LP-13b 11 S216A L500 L109 L109 F503 DATE 04-26-2016 05-23-2016 7 LP-17 3 L208 L208 L615 L208 L615 LP-13 9 L503 SHEET TITLE LP-13 2 L500 LIGHTING PLAN SHEET NUMBER SCALE: 1/4"=1'-0" S 0334 ILLINOIS DESIGN FIRM # 184.006688 ISSUE DD SET 95% SET L210 S219 01 LIGHTING PLAN E 955 ISSUE DATE LP-11 L202 L202 5 1 LP-5 NL L208 L104 SM L208 S220 LP-13 LP-13 8 NL L311 A LP-3h L614 2 10 MASTER LIGHTING SWITCHBANK (ON SHEET E7.0) PROVIDE SWITCHES AS IDENTIFIED BELOW UNDER SET(S) OF COMMON FACEPLATES. SM L615 L503 7 L500 LP-3h 1 LP-17 2 NIGHT LIGHTING LIGHTS IDENTIFIED WITH "NL" TO BE ON UNSWITCHED LEG OF CIRCUIT. 2 LP-9e 2 LP-5f L100 6 8 L302 4 S218 L100 LP-13a COOLER LIGHTS STRIPLIGHTS FURNISHED BY COOLER VENDOR, INSTALLED AND AND WIRED BY ELECTRICAL CONTRACTOR. L302 L203 LP-13a L502 L302 LP-3 9 S100 2 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM L102 L100 3 5 LP-3 L615 LP-13a 6 LP-25 L613 9 HOOD LIGHTING PROVIDE FINAL CONNECTION TO (2) 1-100W INCANDESCENT HOOD LIGHTS. LIGHTS FURNISHED BY HOOD MANUFACTURER. SEE MECH. LP-3h L500 L210 3 LP-9f L100 EXTERIOR SIGN POWER PROVIDE J-BOXES AND (1) DEDICATED 120V, 20A DISCONNECT SWITCH ABOVE ACCESSIBLE CEILING WITH (2) #10 CONDUCTORS AND SEPARATE #10 GROUNDING CONDUCTOR AND FINAL CONNECTIONS FOR THE SIGN. THE SIGN IS SUPPLIED BY OTHERS. FIELD VERIFY THE EXACT LOCATION AND REQUIREMENTS. VERIFY LOCATION W/ PSW PRIOR TO INSTALL. SIGNAGE PERMIT BY OTHERS. 2 L502 FAN L207 LP-13a EMERGENCY/EXIT LIGHTING WIRE EMERGENCY/EXIT LIGHTING TO THE UNSWITCHED LEG OF LOCAL AREA CIRCUIT AS INDICATED. LP-3 2 L210 REFRIGERATION EQUIPMENT CONTRACTOR TO PROVIDE MATERIALS AND FINAL CONNECTION PER MANUFACTURERS SPECIFICATIONS. THE WALK-IN COOLER LIGHT FIXTURE, DISPLAY LIGHTS, DOOR HEATER, PILOT LIGHT SWITCH, AND DISPLAY LIGHT SWITCH IS PROVIDED WITH THE BOX. PROVIDE SEAL-OFFS FOR THE CONDUIT PENETRATIONS AND ALL WIRING AS REQUIRED. 4 0 4 S. 4 LP-9 L614 3 BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. SEE TYPICAL MOUNTING DETAIL. SHEET A5.2. LP-25 2 2 CONTRACTOR NOTE F. I. S202 1 THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. H. LP-9 DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. PROJECT NUMBER: 16-059 A. KEYNOTES FIELD VERIFY ALL CONDITIONS BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 GENERAL NOTES E3.0 1. ALL FIRE ALARM EQUIPMENT SHALL BE OF AN APPROVED TYPE AND BE USED FOR THE PURPOSE IT WAS INTENDED. 2. ALL FIRE ALARM EQUIPMENT SHALL BE INSTALLED PER SECTIONS OF THE LOCAL CODE, ADAAG, NEC, AND NFPA 72 WHICH EVER IS APPLICABLE. 3. HVAC 24VAC LINE S/D RELAY L/S RELAY RTU & MUA (TYPICAL) 4. DUCT SMOKE DETECTOR AND LIFE SAFETY RELAY RTU SHUT DOWN CIRCUIT, TYPICAL FOR EACH UNIT. 5. 6. 7. 6 1 SENSOR/THERMOSTAT CONTRACTOR TO PROVIDE BACKBOX, CONDUIT (IF REQ'D) AND WIRE TO CEILING AREA TO SUPPORT NEW THERMOSTAT OR SENSOR BY MECHANICAL CONTRACTOR. CONFIRM LOCATIONS WITH POTBELLY CONSTRUCTION MANAGER. ALL WIRING AND CABLING SHALL BE APPROVED FOR FIRE ALARM SYSTEM USE AND BE INSTALLED PER NFPA 70 (NEC). 2 WHERE CABLING IS NOT EXPOSED TO THE POSSIBILITY OF MECHANICAL DAMAGE (CEILING HEIGHT, ABOVE BAR JOIST), IT MAY BE RUN EXPOSED AND PROPERLY SECURED TO THE BUILDING STRUCTURE. ALL FIRE WALL PENETRATIONS WILL BE WITH EMT TUBING SLEEVES SEALED ON EACH SIDE OF THE PENETRATION WITH HIGH TEMPERATURE SILICONE FIRE SEAL COMPOUND. SPEAKER LOCATION SPEAKER LOCATIONS SHOWN FOR REFERENCE. LOCATE ABOVE WOOD TRIM. SEE NOTES ON SHEET E1.0 FOR SCOPE OF WORK. 3 MANAGER'S DESK SEE DETAIL 3/E7.0 FOR ALL OUTLET AND CIRCUITING REQUIREMENTS. WALL MOUNTED VISUAL OR AUDIO/VISUAL DEVICES SHALL BE INSTALLED PER LOCAL CODE, ADAAG, AND NFPA 72. THEY SHALL BE MOUNTED 80 INCHES ABOVE FINISHED FLOOR LEVEL OR 12 INCHES BELOW CEILING HEIGHT, WHICHEVER IS LOWER OR AS ENVIRONMENTAL CONDITIONS REQUIRE. MANUAL FIRE ALARMS SHALL BE INSTALLED PER LOCAL CODE AND NFPA 72. THEY SHALL BE MOUNTED 42 TO 48 INCHES ABOVE FINISHED FLOOR TO THE OPERATING HANDLE AND BE WITHIN 5 FEET OF ALL EXIT DISCHARGE DOORS OR AS ENVIRONMENTAL CONDITIONS REQUIRE. CIRCUITING ON THE FLOOR PLAN IS DIAGRAMMATIC FOR CLARITY. CIRCUITING SHALL BE "THRU WIRING" WHERE AND WHENEVER POSSIBLE. VERIFY EXACT EQUIPMENT LOCATION IN FIELD. COORDINATE WITH ON-SITE PROJECT MANAGER. 5 1 13 12 14 17'-5" 3 L602 S L602 9 10 5 6 7 POS EXTEND (1) CAT5e CABLE PER POS, PLUS (1) FOR FUTURE TO JBOXES AS PER DETAIL 12/E7.0. PHONE/FAX ABOVE COUNTER EXTEND (2) CAT5e CABLES FROM MANAGERS DESK TO TELECOM BOX @ 42" AFF. FUTURE POS EXTEND (1) CAT5e CABLE PER POS FOR FUTURE POS TO JBOXES AS PER DETAIL 12/E7.0. WIRELESS ACCESS POINT EXTEND (2) CAT5e CABLES FROM WIRELESS ACCESS POINT JUNCTION BOX LOCATED AT HEIGHT ABOVE HIGH TRIM TO MANAGER'S DESK. VERIFY EXACT LOCATION WITH POTBELLY REP PRIOR TO INSTALLATION. 8 NOT USED 9 SMOKE DETECTOR A SMOKE DETECTOR IS REQUIRED PER NFPA 72 1-5.6 TO PROTECT THE CONTROL UNIT. 10 FUTURE IT EQUIPMENT PROVIDE SINGLE CAT5e CABLE RUN BETWEEN THE JBOX AT LOAD STATION AND MANAGER'S DESK. LOCATE AT 48" AFF NEXT TO ASSOCIATED RECEPTACLE. 11 SECURITY ALARM KEYPAD APPROXIMATE LOCATION OF SECURITY ALARM KEYPAD ABOVE MASTER LIGHT SWITCH BANK. 12 ROUTER ABOVE MANAGER DESK ROUTER TO BE WALL MOUNTED ABOVE MANAGER DESK. SEE DETAIL 03/E7.0. 13 SECURITY ALARM PANEL SECURITY ALARM PANEL TO BE MOUNTED ABOVE MANAGERS DESK ON PHONE BOARD. COORDINATE EXACT LOCATION WITH GC. SEE DETAIL 03/E7.0. 14 PATCH PANEL EXTEND (1) CAT5E CABLE FROM PHONE JACK AT MANAGERS DESK TO PATCH PANEL. A R 4 0 4 S. C Wells H S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 2 S 1 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. St. Louis - Montreal 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com mechanical electrical plumbing fire protection structural ISSUE DATE ISSUE DD SET 95% SET 2 S DATE 04-26-2016 05-23-2016 4 W.H. 11 L601 7 2 2 L601 1 S 1 S SHEET TITLE SYSTEMS PLAN SHEET NUMBER 01 SYSTEMS PLAN SCALE: 1/4"=1'-0" S 0334 ILLINOIS DESIGN FIRM # 184.006688 7'-4" 4 R E7.0 L602 4 E 955 03 1 9 2 4 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM PROJECT NUMBER: 16-059 HVAC 24VAC LINE KEYNOTES BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 FIRE ALARM GENERAL NOTES: E4.0 TYPE MANUFACTURER DESCRIPTION Count MODEL LIGHTING SCHEDULE LAMP FURN INSTALL VOLTS WATTS B.O. FIXTURE COMMENTS L100 DECORATIVE PENDANT - 14" CON-TEC SCHOOL HOUSE FIXTURE 11 CM5601150 W/ 8' ASSEMBLY PHILIPS 11A19/END/2700/DIM 6/1 VD GC 120 23 7'-9" AFF TO BOTTOM SEE DETAIL 09/A5.2 L102 ANTIQUE GLOBE FIXTURE CUSTOM BY PSW DECORATIVE CHAIN HUNG FIXTURE WITH VINTAGE COLORED TEXTURE GLASS SHADE 5 CUSTOM PHILIPS EL/MDT2 13W VD GC 120 14 7'-9" AFF TO BOTTOM SEE DETAIL 09/A5.2 L103 WALL SCONCE JUSTICE WALL SCONCE W/ SHADE 1 POR-8921-20-PLET-DBRZ PHILIPS 11A19/END/2700/DIM 6/1 VD GC L104 WALL SCONCE - TOILET ROOM REJUVENATION SELMA WHITE PORCELEIN 2 A4631 / B2002 SHADE PHILIPS EL/MDT 23W VD GC L109 CYLINDER PENDANT CON-TECH 6" CYLINDER PENDANT W/ 24" STEM KIT AND MONOPOINT 3 CF6-42P-C-B / CSK24-B / LA18-B PHILIPS PL-T 42W/835/4P/ALTO VD GC L200 CEILING MOUNTED FIXTURE THOMAS LIGHTING 2-LIGHT CEILING MTD, PAINTED BRONZE, 13 1/4" 1 PL869263L 2 (13W) CFQ13/G24q/827 (4 PIN) VD GC 120 26 CEILING MOUNTED L202 CEILING MOUNTED TOILET RM FIXTURE REJUVENATION FRANCIS BLACK PORCELEIN W/ BLACK STRIPED SHADE 2 A7685 / B1489 BLACK STRIPED SHADE 23W GU24 LAMP VD GC 120 23 N/A L203 SURFACE MOUNT COOLER STRIP LIGHT METALUX VAPORITE 1 X4 STRIP LIGHT (2) LAMP 1 VT-232-120-EB81 GE F28T8/SP35/UMX/ECO; ORDER CODE: 00256 GC TO PROVIDE LAMPS VD/GC GC 120 42" AFF (LOW TABLES) / 54" AFF (HIGH TABLES) 120 23 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM CENTER FIXTURE ABOVE MIRROR AT 7'-0" AFF 13'-0" AFF TO BOTTOM SEE DETAIL 09/A5.2 FIXTURE BY VENDOR, LAMPS BY GC A R 4 0 4 S. L207 LED TRACK HEAD (MENU) CON-TEC PAR30 ROUND BACK CYLINDER TRACK HEAD 8 CTL230-B SOLAIS LR30LN/25/30K/18W/1000/BK VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A5.2 L208 LED TRACK HEAD (WALL FLOOD) CON-TEC PAR30 ROUND BACK CYLINDER TRACK HEAD 19 CTL230-B SOLAIS LR30LN/40/30K/18W/1000/BK VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A5.2 L210 LINEAR TRACK FIXTURE 48" CON-TEC LINEAR SLIM STYLE WALLWASH 3 CTL14154/HO-B PHILIPS F54T5/835/HO/ALTO VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 13'-6" AFF SEE DETAIL 12/A5.2 L302 RECESSED 2 X 4 COOPER METALUX, 2X4, 3 LAMP FLUORESCENT FIXTURE 5 METALUX 2GR8-332A-UNV-EB81-U, 2X4 RECESSED (3) PHILIPS LED T8 LAMPS; PRODUCT NO: 45359-7; ORDERING CODE: 12T8/48-3500 IF 10/1 VD GC L305 RECESSED 2 X 2 COOPER METALUX, 2X2, 2 LAMP FLUORESCENT FIXTURE 1 2GC8-317A-UNV-EB81-U (3) F17T8/SP35/ ITEM #45743 VD GC L310 6" RECESSED DOWNLIGHT (LED) CON-TEC 6" INCADESCENT HOUSING AND TRIM 2 RL38 + CTR1902-WHT SOLAIS LR38/25/30K/1025BK VD GC L311 6" RECESSED DOWNLIGHT W/ WALLWASH (LED) CON-TEC 6" INCADESCENT HOUSING AND WALLWASH TRIM 1 RL38 + CTR3807-WHT LR38/25/30K/1025BK VD GC L400 CEILING FAN REVOLUTION LIGHTING MARISSA, WALNUT PECAN, NO LIGHT KIT, VENETIAN BRONZE 2 MA52VBT N/A VD GC 120 5 L500 EMERGENCY LIGHT TECHNICAL CONSUMER PRODUCTS EMERGENCY LIGHT TCP 20760 Emergency 7 20760 EMERGENCY HALOGEN LIGHTS VD GC 120 6 L502 EMERGENCY EXIT SIGN W/ LIGHTS TECHNICAL CONSUMER PRODUCTS COMBO EMERGENCY EXIT SIGN W/ (2) HEADS 4 TCP 20723 VD GC L601 WALL MOUNTED SPEAKER SOUNDTUBE WALL MOUNT SPEAKER 2 SM400I VD VD GC TO INSTALL BACKER BOX FOR SPEAKERS L602 CEILING MOUNTED SPEAKER LOWELL 8" DUAL CONE SPEAKER ASSEMBLY 3 R SERIES VD VD GC TO INSTALL BACKER BOX FOR SPEAKERS L610 72" EXTENSION ROD REVOLUTION LIGHTING 72" IRON DOWN ROD - DR72VB 2 DR72VB VD GC FOR USE WITH L400 CEILING FAN. L611 LAMP CHANGER KIT MR. LONGARM INC. LAMP CHANGER KIT 1 B8601 3030 VD GC L613 3' X 5' EXHAUST HOOD JD HIGGINS SS HOOD W/ 18" ENCLOSURE PANEL 2 3624 VD GC L614 4'-0" BLACK TRACK CON-TECH 4'-0" BLACK TRACK FOR LED TRACK HEADS 2 LT-4-B VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A5.2 L615 6'-0" BLACK TRACK CON-TECH 6'-0" BLACK TRACK FOR LED TRACK HEADS 12 LT-6-B VD GC IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF SEE DETAIL 07/A5.2 L617 TRACK END FEED CON-TECH END FEED (ONE NEEDED FOR EACH TRACK) 9 LA-10-B VD GC L618 TRACK CONNECTOR CON-TECH CONNECTOR TO FIT MULTIPLE TRACKS TOGETHER 4 LA-2-B VD GC L619 TRACK CORNER CONNECTOR CON-TECH CONNECTOR TO FIT TRACKS AT A 90 ANGLE 1 LA-12-B VD GC L620 CURRENT LIMITING DEVICE CON-TECH CURRENT LIMITING POWER FEED 5 LA-23-RN VD GC C Wells H I S t ., T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 E 955 R S 0334 ILLINOIS DESIGN FIRM # 184.006688 THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. St. Louis - Montreal 9'-0" AFF TO BOTTOM SEE DETAIL 14/A5.2 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 WILL NOT BE USED IN ALL LOCATIONS. VERIFY WITH ENGINEERING DRAWINGS mechanical electrical plumbing fire protection structural PROJECT NUMBER: 16-059 ITEM # ISSUE DATE ISSUE DD SET 95% SET DATE 04-26-2016 05-23-2016 SHEET TITLE LIGHTING SCHEDULE SHEET NUMBER E5.0 NOTE:EC SHALL USE THIS TIME SWITCH OR APPROVED EQUIVALENT TO COMPLY WITH 2009 IECC. (CHNL 2) LP-15 EXTERIOR SIGN (CHNL 1) ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL CONDUCTORS FOR VOLTAGE DROP. EXTERIOR LP-34 TS TENANT INTERIOR TIMED WALL SWITCH (2 HOUR MAX.) FOR OVERRIDING TIME-SWITCH 30 TS C1 C1 SERVICE AREA LTG. g SERVICE TRACK LTG. LP-13 SET TO TURN ON AND OFF PER PSW DIRECTION ON 24 HRS/DAY LOCK ON CIRCUIT. CHANNELS 2: TIME ON 4:30 PM- MIDNIGHT AND 5:00 AM - 8:00 AM TIME OFF - ALL OTHER TIMES C1: AS DIRECTED BY STORE MANAGER. e C1 DAYLIGHTING a DINING ROOM LTG. b HALLWAY LTG. d LP-5 C1 LP-3 A LOAD STATION DRESS STATION 2'-0" MIN. (COORD. WITH ELEC. PLAN) DISC. SWITCH BY LL TIME CLOCK DETAIL CORD & PLUG SUPPLIED BY VENDOR. NEW PANEL "RP" 208Y/120V, 3Ø, 4W S t ., I T Suite E 300 C T S Chicago, + IL P L A 60607 N N P: 312 Scale: N.T.S. 796 Merus Court St. Louis, MO 63026 T 636.349.1600 F 636.349.1730 aedificacase.com PROVIDE CONTROL WIRING FOR FAN SHUT DOWN (1) RETURN DUCT MOUNTED SMOKE DETECTOR MAPLE CHASE #0550 GC TO PROVIDE EMT DATA CONDUIT IN SECOND BAY OF P.O.STYPE TO BE CAT 5e CABLE (8 TOTAL). PROVIDE 15 FEET OF EXCESS cat 5e CABLE AT P.O.S & 20 FEET OF EXCESS CAT CABLE AT MANAGER'S DESK RISER DIAGRAM 10 Scale: N.T.S. QTY PER PLAN OR AS REQ'D. 1/2"C, 4 #14 SPEAKER WIRES TERMINATED IN CEILING ABOVE MANAGER'S DESK (LEAVE ADEQUATE WIRE SLACK). PHONE BOARD: LOCATED ABOVE THE MANAGER'S DESK. 1/2"C, 4 #14 REMOTE ANNUNCIATOR / RESET SYSTEM SENSOR, MAPLE CHASE #0537, LOCATED PER PSW DIRECTION PROVIDE TYPED LABEL INDICATING "HVAC DUCT SMOKE DETECTOR". GC TO PROVIDE 3 4" FLEX CONDUIT (IN FLOOR OR ADJACENT WALL-REFER TO DRAWINGS) TO 1900 BOX FROM ELECTRICAL PANEL. EXTRA CABLE: PROVIDE AN ADDITIONAL 20' OF SPARE CABLING AT TELEPHONE BLOCK. 2' x 2' x 3/4" PLYWOOD w/FLAME RETARDANT PAINT NOTE: PROVIDE DETECTOR, HOUSING, TYPE, REMOTE STATION, AND ALL ACCESSORIES. DETECTOR SHALL BE INSTALLED UNDER DIVISION 15. CONNECT DETECTOR AS SHOWN. WHEN PSW SPACE IS MONITORED BY CENTRAL BUILDING FIRE ALARM SYSTEM, GC TO COORDINATE WITH LANDLORD'S ALARM CONTRACTOR TO CONNECT BUILDING ALARM SYSTEM TO DUCT DETECTOR AUXILIARY CONTACTS. TERMINAL BLOCKS GC TO PROVIDE (2) 1" DATA CONDUIT mechanical electrical plumbing fire protection structural PHONE SYSTEM MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL DUCT DETECTOR WITH MINIMUM TWO SETS OF AUXILIARY CONTACTS ISSUE DATE ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL CONTROL WIRING FROM DUCT DETECTOR TO AC UNIT SECTION THRU POS COUNTER FROM CUSTOMER SIDE Scale: N.T.S. 8 1 Cat5e 2 Cat5e ISSUE DD SET 95% SET 1 Cat5e DUCT SMOKE DETECTOR DATE 04-26-2016 05-23-2016 Scale: N.T.S. 24 PORT CISCO SWITCH PATCH PANEL WINDSTREAM ROUTER (LP-23) 8'-8" SECURITY ALARM PANEL (LP-21) 30" X 60" - 3/4" FRT PLYWOOD PHONE BOARD ABOVE SHELVING, PAINT TO MATCH WALL. MUSIC PLAYER & AMP 5" SERVER QUAD OUTLET MOUNTED ON PHONE BOARD FOR PHONE EQUIPMENT. (LP-36) DEDICATED DUPLEX OUTLET FOR SOUND SYSTEM (LP-41) PROVDE 4" SQUARE JUNCTION BOX AND 1-1/4" CONDUIT TO ACCESSIBLE CEILING FOR SOUND SYSTEM ISOLATED GROUND, DEDICATED QUAD OUTLET FOR POWER SUPPLY (LP-40) SWITCH 6" 9" POWER SUPPLY 3'-10" 3'-4" OUTLETS FOR GENERAL USE (LP-42) e f g h i S S S S S S S S S DATA LINES TO MANAGER'S DESK EQUIPMENT MANAGER'S DESK (1) RJ45 (2) RJ45 (1) RJ45 (1) RJ11 (1) RJ45 S INDICATES SWITCH SHEET TITLE NOTES: 1. ALL WORK AND MATERIALS FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, UNLESS NOTED OTHERWISE. 2. PROVIDE PLENUM RATED CABLING FOR ABOVE THE CEILING WHERE "PLENUM RATED AIR SPACE" SYSTEMS ARE REQUIRED. 3. PROVIDE CONDUIT FOR DATA LINES IF REQUIRED BY CODE. 4. DATA TERMINATION BY POTBELLY VENDOR. ELECTRICAL DETAILS 6'-2" 4'-0" 1'-6" SAFE SHRED 4'-11" d a - STOREFRONT LTG/DAYLIGHTING b - DINING LTG c - CEILING FANS MOTORS d - HALLWAY LTG (IF REQUIRED) e - SERVICE AREA-PERIMETER LTG QUEING f - SERVICE AREA-PERIMETER TRACK LTG g - SERVICE AREA-PERIMETER CENTER LTG h - PREP AREA LTG i - DINING, MUSICIAN (IF REQUIRED) 4'-9" 4'-8" c P.O.S. TERMINAL CONTROL ZONE SCHEDULE 3'-9" FILE CABINET b P.O.S. TERMINAL REMOTE PHONE/FAX NETBOOK (3) JBOXES FLUSH FOR VOLUME CONTROLS. PROVIDE STAINLESS STEEL BLANK PLATES FOR UNUSED OPENINGS. a P.O.S. TERMINAL JBOX FOR FUTURE IT NEEDS PRINTER WALL MOUNTED PHONE SHEET NUMBER NOTE: ALL ZONES MAY NOT BE USED. REFER TO E3.0 FOR ADDITIONAL INFORMATION. 3 S 0334 St. Louis - Montreal EC IS RESPONSIBLE FOR FIELD VERIFICATION OF SITE CONDITIONS AND COORDINATING ALL ELECTRICAL SERVICE REQUIREMENTS WITH LOCAL UTILITY. EC SHALL REPORT ANY DIFFERENCES OR DISCREPANCIES TO ENGINEER PRIOR TO BID. NO EXTRAS OR CHANGE ORDERS SHALL BE GIVEN FOR THE EC'S FAILURE TO VISIT SITE PRIOR TO BIDING. Scale: N.T.S. SAMPLING TUBE SIZED FOR DUCT GC TO PROVIDE A 1-1/2" DEEP J-BOX WITH SINGLE QUAD RECEPTACLE. CIRCUIT TO BE ISOLATED DEDICATED. REFER TO PANEL SCHEDULE. POS END PANEL 3'-2" R SINGLE OVEN OUTLET / BACK BOX DETAIL 7 HVAC DUCTWORK NOTE: ALL CONDUITS, CABLING, J-BOXES & DEVICES SHALL BE MOUNTED IN MILLWORK STUD WALL SO NOT TO INTERFERE WITH THE OPERATION OF THE REMOVABLE FRONT PANEL OF THE POS COUNTER. THERMOSTAT LOCATIONS. PROVIDE SINGLE GANG JUNCTION BOX W/ PULL STRING TO ACCESSIBLE CEILING. PROVIDE SAME NUMBER OF BOXES AS HVAC UNITS, TYP (2) STACK THERMOSTATS. E 955 GENERAL CONTRACTOR AND ELECTRICIAN TO REFER TO LEASING AGREEMENT PRIOR TO BIDDING 120 V 2 H NEW PANEL "LP" 208Y/120V, 3Ø, 4W EC TO PROVIDE 2 SETS OF (4#3Ø +1#3 GND IN 2"C) IN LL PROVIDED CONDUIT AS REQUIRED 1'-6" SPARE * = ALL EMERGENCY/EXIT/NIGHT LIGHTING SHALL BE CIRCUITED AHEAD OF ALL LIGHTING CONTROLS. GC TO MOUNT (1) EMPTY J-BOX IN EACH OF (3) CENTER BAY SECTIONS ON 2X4'S. J-BOXES TO BE TYPE 1900 (1-1/2" DEEP) WITH 1/2" MUDRING READY TO ACCEPT DATA CONNECTION PLATE. INSTALL BX CONNECTOR TO ACCEPT DATA WIRE. NEW PANEL "PP" 480Y/277V, 3Ø, 4W PREP ROOM LTG. C1 1 C Wells THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED. C/T BY LL GC TO PROVIDE LEVITON 8450 RECEPTACLE - (1) PER OVEN. PLUG TO BE PERPENDICULAR TO FLOOR DINING ROOM TRACK C1 NEW 4-#2/0 THWN & 1-#6, 2"C NEW 3#4 THWN & 1#6 1 1/4" C h -- R 4 0 4 S. M ILLINOIS DESIGN FIRM # 184.006688 f C1 NEW #6 CU. NEW #6 CU. PROJECT NUMBER: 16-059 LP-9 SPARE EC TO INSTALL METER PER UTILITY COMPANY REQUIREMENTS WIRE TROUGH 111 N. CANAL STREET, SUITE 850 CHICAGO, IL. 60606 P: 312.951.0600 F: 312.951.0300 WWW.POTBELLY.COM "T-LP" 45KVA, TRAPEZE OR WALL MOUNTED XFMR. 480V, 3Ø, DELTA PRI.-208/120V, 3Ø, 4W WYE SEC. BAL - ELKRIDGE LANDING: 1622 W. NURSERY ROAD, SUITE C LINTHICUM HEIGHTS, MD 21090 -- LIGHTING/SIGNAGE CONTROLLER: TORK MODEL #DZS200BP 120V, 2 CHANNEL ELECTRONIC TIMECLOCK WITH MANUAL OVERRIDE. INCLUDE ALL CONTROL WIRING AS REQ'D PER MANUFACTURER. PROVIDE CONTACTORS AS REQ'D TO PROVIDE SUFFICIENT POLES FOR ALL LIGHTING AND SIGNAGE. TIMECLOCK AND CONTACTORS TO BE PROVIDED WTIH NEMA-1 ENCLOSURES. "T-RP" 45KVA, TRAPEZE OR WALL MOUNTED XFMR. 480V, 3Ø, DELTA PRI.-208/120V, 3Ø, 4W WYE SEC. MANAGER'S DESK - POWER ELEVATION Scale: N.T.S. 9 MASTER LIGHTING SWITCHBANK Scale: N.T.S. 12 P.O.S. DATA/PHONE/VIDEO ONE-LINE DIAGRAM Scale: N.T.S. E7.0