V-SPERM IIITM
Transcription
V-SPERM IIITM
V-SPERM III TM USER GUIDE V e r s i o n 3 . 4 5 Catalog #7416 February, 2006 V-SPERM III™ User Guide ver. 3.45 Table of SECTION 1: Overview Contents V-Sperm III Features and Benefits System Requirements 3 3 SECTION 2: Start-Up 4 SECTION 3: Set-Up 5 Set-Up: V-Sperm Authorized Users Report Test Parameters Normal Ranges Testing Facility Language Ports Set-up: SQA-V Version 2.45 System Controls 5 5 5 6 6 6 6 7 7 7 7 SECTION 4: Importing/Exporting Data from the SQA-V 8 Importing SQA-V data to V-Sperm III Exporting SQA-V data 8 8 SECTION 5: Navigating through V-Sperm III 9 SECTION 6: Patient Data 9 Locating, Selecting and Authorizing Records Enter Patient Name Graphs Attach Video/Picture to a Test Record Enter Manual Test Data Test Report View/Attach Images Authorize Test Results Delete Records 9 10 11 11 12 12 13 13 13 SECTION 7: Video 14 SECTION 8: Controls 14 SECTION 9: Utilities 15 SECTION 10: Log-off 16 SECTION 11: Exit 16 SECTION 12: Installation 17 SECTION 13: Uninstall 19 2 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 SECTION 1: Overview V-Sperm III Features and Benefits • • • • • • • • • • Import patient and control data from the SPERMALITE/SQA-V. Consolidate entire semen analysis work-up into one report with sperm image attached. View "real time" semen samples (from the SQA-V) on a PC screen. Attach video clips of POSTVASECTOMY test results to patient files for documentation purposes Save patient's test results with video clips or still images attached Edit patient files and add supplementary test results – track changes with built-in traceability feature Save, view and graph PATIENT and CONTROL test results Set-up SQA-V system defaults Customize reports by language, test range, test descriptions Access V-Sperm via person/password security The V-Sperm III package includes the following: • • • • • V-Sperm III User Guide V-Sperm III Version 3.45 Installation CD V-Sperm Security device USB Instant Video CD external device (or PBI internal device) RCA video cable System Requirements • • SQA-V with communication cable and power cable PC computer • • Hardware requirements • 1Ghz or higher CPU • 256 megabytes RAM • AGP Video Display Card with at least 16 megabytes of RAM memory • CD-ROM compatible drive • RS232 communications port (serial) • Two available USB ports Software requirements • Compatible operating systems: 3 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 • • • • • • • Windows XP Windows 2000 Windows 98 (Windows 98 installation CD may be required during the V-Sperm III installation process) DirectX 8.1* At least 40 Gbyte of free hard disk space (if not using a compression tool) or 400 MB if a video compression tool is used. Video resolution ≥ 640x480 Video color quality ≥ 16-bit *NOTE ON DIRECTX installation: DirectX 8.1 is pre-installed on Windows XP. To install on other operating systems follow instructions obtained through the websites listed below: Windows 2000 http://download.microsoft.com/download/win2000pro/Update/8.1/NT5/EN-US/DX81NTeng.exe Windows 98SE / Windows ME: http://download.microsoft.com/download/win98/Install/8.1/W98Me/EN-US/DX81eng.exe SECTION 2: Start-Up After successfully installing V-Sperm III (see section 13 of this guide for instructions) an icon will appear on the desktop. To start the program either: • • NOTE: When logging on for the first time use the Administrator account: User Name: administrator Password: fertility Double click the V-SPERM icon or Click the START button > PROGRAMS > V-Sperm > V-Sperm The V-Sperm III log-on screen will appear. V-Sperm III has a security feature. Each user must be set-up by the Administrator in order to access the program. Only the Administrator can sign-in initially: • • • User Name: administrator Password: fertility Click OK SECTION 3: Set-Up Set-up: Click the Set-up button to select the system defaults for the: • • SQA-V (System and Controls) V-Sperm (System and Controls) 4 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 V-Sperm Set Up: Authorized Users Select SET UP >V-SPERM > AUTHORIZED USERS and the screens below will be displayed. Only the administrator has an authorization to set-up passwords and new users. NOTE: Enter new users by clicking an open cell under the "Title" column. A drop-down menu will appear. Select the type of user based on their rights to the system. Enter the required information and click APPLY. There are four types of users. Each type is permitted different "rights" to the system: • • • • • • • Administrator: Has all rights – can authorize reports, set-up passwords and new users. Authorizing Signature: Has all rights except for setting-up users/passwords. Test Performed By: Has all rights except for authorization of reports and setting-up users/passwords. Ordering Physician: Has no rights and can only view information. Changes can be made to Authorized User's passwords at any time by entering a new one over the old one and clicking APPLY. Changes cannot be made to an authorized user's "title" if a test report in the database contains their name/title. An authorized user cannot be deleted if a test report in the database contains their name/title. Set-up: Report To set-up the test report, click SET-UP >V-SPERM> REPORT. Four option tabs will be displayed. Click one of the option tabs: • • • • TEST PARAMETERS NORMAL RANGES TESTING FACILITY LANGUAGE 5 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 Test Parameters: NOTE: All test parameters are listed on the patient's semen analysis report. If a test parameter is not checked, results of that test will not be reported on the patient's semen analysis report. • • • Select the information to be viewed on the V-Sperm screens and reported on the test report. Click the √ column to select the test report parameters. Click APPLY to enter. Normal Ranges: NOTE: Some test ranges have been set by the manufacturer as a factory default based on WHO or MES guidelines (see SQA-V User Guide). • The user can input values based on internal lab protocols. • The test report will indicate if a test result is out of the range established by the user. • • • To set the normal range for a test result, click the ARROW pointing to the parameter to be set. The Normal Range Settings screen will appear. Enter the desired symbol (≥, <, =, etc.). Enter the desired value. Click APPLY to enter. Testing Facility: • • • • Enter the name, address, phone and fax number of the testing facility to be displayed on the semen analysis report. Enter the appropriate information. Check the Show in Report box. Click APPLY to save the changes. Language: • • • • • English is the system default language. The system allows the user to select “Other 1” or “Other 2” to input other languages into the system. Chose “Other 1” or “2” from the Language drop-down menu and the test parameters will be displayed. Enter the test in any language. Click APPLY to save the changes. 6 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 Set Up: Ports To set-up the PC ports, click: • • Set-Up >V-Sperm> Ports. Select a port and click APPLY SQA-V Set-up (SQA-V version 2.45): All of the SQA-V system and control defaults are set-up in V-Sperm III and transferred to the SQA-V. To set up defaults both the SQA-V and V-Sperm III must be activated: • • • NOTE: Some settings have been set by the manufacturer as factory defaults. The RS232 communication cable must be plugged into both the PC and the SQAV. The SERVICE DATA screen of the SQA-V must be displayed. To activate this screen go to: MAIN MENU>SERVICE>SERVICE DATA. From the V-Sperm III main screen select: SET-UP >SQA-V A set-up screen will be displayed that allows the user to input the default settings for both the SQA-V SYSTEM and CONTROLS. SQA-V set-up screen from V-Sperm III CONTROL set-up screen from V-Sperm III PLEASE NOTE: All Set-up fields must have data in order to transfer information to the SQA-V. If CONTROL settings are not known, enter “0” LOT #/ Target Value/+/Range. Enter current date for the date field. If “0” was entered, remember to setup Controls before running Beads or Stabilized Sperm • • • Data must be entered in all fields in order to transfer data to the SQA-V. SQA-V System Default settings; • • • • • Date Format (DD/MM/YY) or (MM/DD/YY) Local date setting Conc./Chamber Standard 1 or 2 (See appendix section for more information) Morphology Criteria (WHO 3rd or WHO 4th Strict) Printing options: automatically print test results/self test reports Control Set-up (from the manufacturer’s labeling): • • • • Select type of control: Latex beads or Stabilized Sperm Enter Lot Number for each control level (enter “0” if not known) Enter +/- Range for each control level (enter “0” if not known) Enter EXPIRATION date (use current date if EXP date not know) 7 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 NOTE: The Set-up data transfer may take several minutes! Please wait….. • • Press the Report button to print the selected default settings Press Apply to accept the default settings and transfer settings to the SQA-V SECTION 4: Importing/Exporting Data from the SQA-V Importing the SQA-V data to V-Sperm III SQA-V Patient and Control test results can be viewed from V-Sperm III once they have been imported from the SQA-V to V-Sperm III. Follow the steps below to import data: • • • • • NOTE: If a message has been displayed on the SQA-V stating that the archive is almost full, select YES to delete the SQA-V archive after importing it to V-Sperm • • • The RS232 communication cable must be plugged into both the PC and the SQA-V. The SERVICE DATA screen of the SQA-V must be displayed. To activate this screen go to: MAIN MENU>SERVICE>SERVICE DATA. From the V-Sperm III main screen select: SET-UP >SQA-V Click the IMPORT/EXPORT navigation button of the V-Sperm III. Select IMPORT ARCHIVE (Patient Data) or IMPORT CONTROLS. Click CONTINUE on the V-Sperm III import data screen. The user is given the option to delete the SQA-V Control Archive data once the import function has completed. Select YES or NO. Exporting the SQA-V data: The Export data option allows the user to Export the Patient data archive and the QC archive to an external file (Excel format) on the PC: • • • • Click the IMPORT/EXPORT navigation button of the VSperm III. Select EXPORT DATA Select EXPORT ARCHIVE (Patient Data) or EXPORT CONTROLS (QC Data). Enter the path and file name; then click SAVE. 8 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 SECTION 5: Navigating through V-Sperm NOTE: Eight navigation buttons divide the V-Sperm III program into distinct modules. • • • • • V-Sperm III is set-up so the user can easily navigate through the various menus and options by clicking buttons. Eight main navigation buttons are always available in the left margin of the screen to lead the user through a variety of options. When a main navigation button is selected, new submenu buttons appear across the top of the V-Sperm III screen. The sub-menu buttons allow the user to easily access the features of the V-Sperm III software. A variety of icons guide the user through V-Sperm III features and options. Directional indicator buttons allow the user to easily move back to the previous menu. SECTION 6: Patient Data Locating, Selecting and Authorizing Records To select a record, click this icon. NOTE: In order to locate a record in V-Sperm III, the record must first be imported from the SQA-V archive to the V-Sperm III database. NOTE: The patient's name can be added to the record in the V-Sperm database. Locate new records by patient ID and enter the patient's name in the screen provided. NOTE: The option to view the "Authorization List" is only available to the user who has "Authorizing Signature" rights in the V-Sperm III program. Click the Patient Data button and three options for locating records will appear: • • Patient List – a complete list of all the patient files in the database. • Sort the records by clicking the COLUMN TITLES: Patient ID, First Name, Last Name, etc. • Click the ARROW pointing to the desired record to select it. Patient List Search by Patient – if the name or the patient ID number is known, records can be located using this option • Enter the first or last name or ID number of the patient • Click SELECT. Clicking this icon will display the semen analysis report 9 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 • Select the required tests to authorize using this icon. Authorization List - a complete list of all records requiring an authorized signature. To authorize a report: • Click on the REPORT icon to view a record before authorizing it. • Click on the √ COLUMN to the left of the record to be authorized. • Click the AUTHORIZE button to complete the process. • Authorization List Once authorized, the test will be deleted from the list. Patient Data: NOTE: If more test results need to be displayed on the Patient Data Screen, go to: Setup > Report > Test Parameters. Add additional tests by clicking the √ column. These additional tests will now be displayed. • • • • This icon indicates that the record has a video clip attached. This icon indicates that the record has a picture attached. • The Patient Data Screen will now be activated. Patient Data Screen - Displays all of the test records for the selected patient, listed separately. The title bar above each test displays icons indicating file attachments (pictures, graphs, etc.) and test authorization status. Patient List A number of functions can be performed from this screen: Enter Patient Name: • This icon indicates that the test results have been authorized. Select a patient record from the Patient List by clicking on the ARROW pointing to the desired record. • From the Patient Data Screen, click on the field for First Name, Last Name and type-in the information. Click: Apply to save. Patient Data Screen 10 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 Graph Semen Parameters: Click this icon to run a graph of the selected test results. NOTE: Only a picture can be attached to a semen analysis report. Video clips are attached to patient files in V-Sperm III for reference and documentation purposes. • • Run graphs to compare test results from multiple analyses. From the Patient Data Screen, click the graph icon next to the parameter to be graphed. A graph will display the history of test results for the selected test parameter. Attach Video/Picture to a Test Record • • • • • • • • • • • • • Run a test in the SQA-V and import the test results into V-Sperm III (see Importing/Exporting Data) Activate the Patient Data Screen of V-Sperm III following the directions above: Patient Data>Patient List Insert a slide or testing capillary into the video visualization system of the SQA-V Select the desired patient’s record If the patient has multiple records, select the appropriate test record by clicking the record TITLE bar to mark the test column. Click the PREVIEW VIDEO button to view the live specimen. Click CAPTURE PICTURE to attach a still image to the patient record. Click CAPTURE VIDEO to attach a live video to the patient record (for POSTVASECTOMY samples this is recommended). Once this option is selected, a STOP CAPTURING button will appear. A timer will indicate the length of the recording time. Click the Stop Capturing button when satisfied with the video. A message will indicate Video Saved. Click OK to end. 11 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 Enter Manual Test Data • • • From the Patient Data Screen, click the Enter Data button to display a table that allows the user to input manual test results and add comments to the semen analysis record. All manual entries are tracked via a traceability function. Click the Traceability button at the bottom of this screen to run a Traceability Report. Enter Manual Test Results Traceability Report Test Report NOTE: If some of the test results are not displayed on the Semen Analysis Report, it is possible that tests were not selected during the set-up process. Go to: Set-Up > VSperm> Report > Test Parameters and add additional tests by clicking the √ column. From the Patient Data Screen, click the Test Report button to view and print the two-page semen analysis report. • • • • • Arrows indicate test results are out of range. • • Click the export icon to export the semen analysis report to .doc format . • Move between pages by using the page bar at the bottom of the screen. Print the report by clicking the printer icon. Pictures can be attached. Use ZOOM to minimize/enlarge the report. Exit the report by clicking the X in the upper right hand corner of the screen. If test results are out of range a yellow arrow will be displayed. Click the FILE EXPORT icon to export the report to a file. Enter the path and file name; then click SAVE. 12 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 View/Attach Images: • This icon indicates a video clip is attached to a record. This icon indicates a picture is attached to a record. NOTE: If there are no saved images in a patient's file, the table will not appear. NOTE: Click the image to maximize it. Note: when clicking the image a GRID and FREEZE options will be displayed for counting Click the "X" in the upper right hand corner of the image to close it. • • • • • • • • To view an image: From the Patient Data Screen select a test record with a video/camera icon displayed in the title bar. Click the View/Attach Images button. An Image Browser will display all the images attached to the selected patient's record. Select an image and it will be displayed in the preview pane. Click on the image to enlarge it. Click the SAVE AS button to save the picture to an external file on your PC. To attach an image (not video) to a patient record, click on the report icon column in the row of the picture to be attached. A report icon will now appear in the column indicating that the picture is attached to the semen analysis report. Image Browser To delete an image, select it by clicking on it and then use the DELETE key from the PC keyboard. Authorize Test Results NOTE: The Authorize button is activated when the user with "Authorized Signature" rights is logged into the system. To authorize a single test from the Patient Data Screen, select a patient file. • • • Select a test report from the patient file (if more than one). Click the AUTHORIZE button. To authorize a group of test results refer to the section: Patient Data: Locating, Selecting and Authorizing Records. Delete Records There are three types of records in V-Sperm III: • • • Patient Records Test Records Image All types of records are deleted in the same manner. Highlight the patient record, test record, or image and use the DELETE key on the PC keyboard. 13 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 SECTION 7: Video Activate the VIDEO navigation button to view semen samples "live" from the SQA-V visualization system. Two options are available from this feature: • • Real Time Video – activates the video so samples can be viewed. Video Settings – select grid size, color and video compression. Click REAL TIME VIDEO and seven options are available: • • • • • • • Freeze – allows the user to view the specimen for counting/evaluating cells. Grid – the grid can be displayed or removed by clicking this button. Counting from this grid is the SAME as the SQA-V grid (20 squares – each cell in the entire grid = 1M/ml as long as the ZOOM on the SQA-V is set to x300). Copy – captures a picture that can then be saved to another application (such as Word). Settings – displays the video capture device settings. Save Video – captures and saves a video clip to an external file. Save Picture – captures and saves a picture to an external file. Full Screen – maximizes the image to full screen. Click the mouse to return to normal size. SECTION 8: Controls SQA-V Control Archive: The SQA-V Control archive can be viewed and managed from the V-Sperm system only. To view a complete table of all archived control test results the archive should be imported from the SQA-V to the V-Sperm via the IMPORT mode (Refer to Section "Importing Data from the SQA-V Archive"). A complete table of all archived test results will be displayed. The user can select requested records and export the data to a file. Running Control Test Report: • • To run a control test report click the CONTROL tab in the main navigation menu: The user should select the following fields in the: • Test Method – Manual or Automated • Control Media – Latex Beads or Stabilized Sperm • Control Level – level 1, 2 or Negative Control • • Date Range Click the RUN REPORT button 14 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 • This icon indicates that a test has been selected. • • Click this icon to print a copy of the report. A table will be displayed according to the user’s selected options. From this table the user can sort the data by clicking on the title tabs of each column. Corrective Action can be filled in for any test that is out of range by clicking on the appropriate “cell” in the “Corrective Action” column. A menu of corrective actions will be displayed and the user can readily select a defined action or write in the corrective action by selecting “other”. Control Test Results Table Corrective Action Table Select/deselect the requested test results and click the TEST REPORT button to view the test report. Click this icon to export the report. Control Test Report Control Test Report • • Use the PAGE BAR to move between pages (if necessary). Use the ZOOM function to maximize/minimize the report. SECTION 9: Utilities The UTILITIES navigation button opens an Archive Management function. The user can view the SQA-V archive and selectively import or delete individual or groups of records from the SQA-V archive. This feature is particularly useful for importing POSTVASECTOMY files/test results: • • After viewing the sample in the SQA-V visualization system, leave the testing capillary in the testing compartment. FINISH running the test, SAVE and immediately IMPORT the file to V-Sperm and ATTACH a video. In order to use this function: • • The RS232 cable must be connected to both the PC and the SQA-V. Activate the SQA-V and go to: MAIN MENU > SERVICE > SERVICE DATA. 15 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 • • • • On V-Sperm III click the: UTILITIES navigation button. Then select ARCHIVE MANAGEMENT The SQA-V archive is now displayed in V-Sperm III. SQA-V records are color coded: • Dark blue – the current record the user has highlighted with the cursor. • Light blue - records not yet imported into V-Sperm (the user can easily locate new records of tests just run by the color). • • White - records already imported into V-Sperm The user can now individually select records by clicking on the left hand column of the table and: • • • • Import the selected record(s) from the SQA-V archive into VSperm The record highlighted by the user New records not yet imported to V-Sperm III Records already imported to V-Sperm III Selected records Delete the selected records from the SQA-V archive. Delete all records from the SQA-V archive. Exit the function. SECTION 10: Log-Off LOG-OFF V-Sperm III by clicking the navigation button and confirming with a click. • • A new user can immediately log-on from the screen. The V-Sperm III program does not need to be shut-down when a user logs-off. SECTION 11: Exit To Exit – Click on the OK button 16 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 SECTION 12: Install Software Overview: DO NOT PLUG IN THE VIDEO CAPTURE DEVICE UNTIL THE END OF THE INSTALLATION PROCESS OR THE INSTALLATION WILL FAIL!! Follow the instructions below carefully. First, V-Sperm III software needs to be installed (before plugging-in the video capture device!), then the Video Capture software has to be installed (before plugging-in the video capture device). Then the Video Capture Device and Security Key will be installed. First, software then the hardware. NOTE: If installation fails to start automatically, run X:\Setup.exe (X is the letter of the PC CDROM drive). NOTE: Refer to the "System Requirements" section for details regarding the minimum requirements for running V-Sperm III. NOTE: Skip to Phase 3 if the MDAC message is not displayed NOTE: It is highly recommended to use the manufacturer's automatic default settings. Phase 1: Software Installation Step 1: Insert the V-Sperm III CD into the PC CD-ROM. Installation will begin automatically. Step 2: The screen will display: Initializing Wise Installation Wizard. Step 3: Close any programs that are open or running. Step 4: Run the installation program. Step 5: When the installation program is finished click YES to proceed. Phase 2: MDAC Installation Step 1: A message will appear if MDAC (2.6 or above) is not installed on the PC. Step 2: Click OK to install. Step 3: Once installed, restart the computer by clicking OK when prompted. Step 4: The computer will re-start and automatically begin installation. Step 5: Click YES to proceed. Phase 3: Collecting Information Step 1: When the Welcome screen is displayed, click Next to proceed. Step 2: The message "Please wait, installation is looking for a previous version" will be displayed. Step 3: If a previous version is on the computer please proceed to “Phase 6: Import Data from a Previous Installation” Step 4: Click NEXT when the default directory for V-Sperm III is displayed. Step 5: Click NEXT when the default name for V-Sperm III is displayed. Step 6: Click Next to begin copying files (all information required for installation has been gathered). 17 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 Phase 4: Installation Process NOTE: If the video capture device drivers have been previously installed, proceed to the next installation phase. WARNING: Do not connect the video capture device or the security device until the software installation is complete and the PC has been restarted. Step 1: When all files have been copied the message: Updating System Configuration, please wait… will be displayed. Step 2: The security device driver will be installed and the screen will indicate that this operation is in process. Phase 5: Install USB Instant VideoCD (video capture device) Step 1: Step 2: Step 3: Step 4: Step 5: The USB Instant VideoCD driver installation software will now begin with a Welcome screen. Click NEXT. Click NEXT when the next screen displays USB Instant VideoCD information. Installation progress will be displayed on the screen.* A message will indicate when the installation is complete. a. Answer YES if asked to restart computer. b. Do not plug-in the video capture device at this time. Click FINISH to close the USB Instant VideoCD installation. *Windows 2000 or Windows XP: a digital signature warning may appear – click Yes or Continue Anyway. Windows 98: you may be prompted to insert the Windows 98 installation CD. Phase 6: Installation Complete Click OK to restart the PC and completed the software installation. NOTE: The option to "Search for the drivers manually" or "Install drivers automatically" may be displayed periodically. Choose: Install the drivers automatically. As a result the PC may need to be restarted. Windows 2000 or Windows XP: A digital signature warning may appear – click Yes or Continue Anyway. Windows 98: The Windows 98 installation CD may have to be inserted into the CDROM. Video Capture Device Installation Step 1: Once the system has been successfully restarted, plug the USB Instant VideoCD device into a free USB port on the computer. The drivers will be automatically installed. Step 2: Click OK to restart the PC and complete the Video Capture Device Installation. Step 3: Once the driver installation is complete, plug in the RCA video cable as illustrated. Step 4: Plug one end of the RCA Video Cable into the SQA-V's video output port on the SQA-V rear panel. Step 5: Plug the other end of the RCA Video Cable into the USB Instant VideoCD video port. Plugging the USB Instant VideoCD device to a free USB port Plug in RCA video cable 18 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 WARNING: V-Sperm III cannot operate without the security "key" properly installed and connected at all times Security Device Installation • • Plug the V-Sperm security device into a second free USB port on the computer. The V-Sperm security device will be automatically installed. Plug the V-Sperm Security device into a second free USB port NOTE: The RS232 communications cable is supplied with the SQA-V. SQA-V Communications Cable • • Connect one end of the RS232 communications cable to the PC. Connect the other end of the RS232 communications cable to the SQA-V. Communications cable connected SECTION 13: Uninstall V-Sperm Uninstall STEP 1: WARNING: Close V-Sperm and any other open programs before beginning the uninstall process. From the desktop of the PC select: START > PROGRAMS > V-SPERM > UNINSTALL. Step 2: A message will be displayed: Initializing Wise Uninstall Wizard… Step 3: Select AUTOMATIC when the screen asks for an uninstall method. Step 4: Click NEXT to continue. Step 5: Click FINISH when the next screen notes that the uninstall has been completed. Step 6: Select YES TO ALL if a message asks to remove shared components. Step 7: Uninstall will remove shared components/files and close automatically when the process is complete. Step 8: RESTART the computer if prompted to do so. 19 Release: 02_06 V-SPERM III™ User Guide ver. 3.45 WARNING: It is highly recommended that the user close all programs before uninstalling the USB Instant VideoCD device. USB Instant VideoCD Uninstall Step 1: Disconnect the USB Instant VideoCD device from the PC. STEP 2: From the PC desktop run: START > CONTROL PANEL > ADD OR REMOVE PROGRAMS > USB INSTANT VIDEOCD > CHANGE/REMOVE. Step 3: The screen will note the initialization of the uninstall process. Step 4: Click OK to the message Do you want to completely remove the selected application and all of its components? Step 5: Click FINISH when the USB Instant VideoCD drivers have been successfully uninstalled. 20 Release: 02_06