Belterra Residential Design Guidelines
Transcription
Belterra Residential Design Guidelines
Doc BELTERRA RESIDENTIAL DESIGN GUIDELINES Bk OPR Vol 2218 Doe Bk 03014643 OPR Vol 2218 BELTERRA RESIDENTIAL DESIGN GUIDELINES IN ACCORDANCE WITH THE COVENANTS, CONDITIONS AND RESTRICTIONS FOR BELTERRA AS RECORDED AMONG THE LAND RECORDS OF HAYS COUNTY, TEXAS, IN BOOK AT PAGE (THE "COVENANTS"), ALL RESIDENTIAL IMPROVEMENTS IN BELTERRA MUST BE APPROVED BY THE NEW CONSTRUCTION COMMITFEE OF THE BELTERRA HOMEOWNERS' ASSOCIATION, INC., A TEXAS NON-PROFIT CORPORATION, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. THESE DESIGN GUIDELINES MAY BE AMENDED, MODIFIED, SUPPLEMENTED AND/OR REPEALED AS AND IN THE MANNER PROVIDED IN THE COVENANTS, WITHOUT PRIOR NOTICE, AND IT IS THE RESPONSIBILITY OF ALL INTERESTED PERSONS TO OBTAIN THE CURREN7 DESIGN GUIDELINES FROM TIME TO TIME IN EWECT. CAPITALIZED TERMS USED IN THESE DESIGN GUIDELiNES WITHOUT DEFINITION HAVE THE RESPECTIVE MEANINGS ASSIGNED TO SUCH TERMS IN THE COVENANTS. I. INTRODUCTION Belterra is a master planned, mixed-use community of MAK FOSTER RANCH, L.P., a Delaware limited partnership, located within the extratemtorial jurisdiction of the City of Dripping Springs and in Hays County, Texas. These guidelines are intended to provide for a uniform standard of quality and design in order to preserve and enhance the orderly development, use and enjoyment of the community for its owners and occupants. Project Description Belterra encompasses more than 1,600 acres and has been planned to include a broad range of residential development in a coordinated suburban setting and a conceptual community plan is attached to these Guidelines as Schedule 1. The conceptual plan is a dynamic document subject to refinement and modification by the Developer as project development occurs, and the Developer reserves the full right to amend its development plans and approvals for Belterra at its sole election and for its own purposes, and neither the conceptual plan attached to these Guidelines nor any other no plan(s) or plat(s) or public approval(s) at any time existing or described or depicted in sales literature or otherwise for Belterra is intended to or shall constitute a final undertaking, representation or commitment by the Developer to any person. As of the date of adoption of these Guidelines, the Developer intends that single-family detached residences will be the dominant land use within Belterra planned residential sections of varying lot sizes and configuration, and distinct price ranges. The street system, BELTERRA RESIDENTIAL DESIGN GUIDELINES Doc #:WASO1 (32028&OO®4) 4138374v2;4/30/2003(flme:17:35 PAGE i P Bk 03014643 OPR Vol 2218 landscaping, walks and greenbelt areas of Belterra have been designed to be compatible with the natural characteristics of the land and, in addition, to visually and functionally interconnect the various sections of the community and to provide an integrated vehicular and pedestrian network. Intent of Guidelines These Guidelines are intended to create a community standard of quality for allofBelterra, and hereby are adopted by the Developer as the Design Guidelines for the Belterra Homeowners' Association, Inc., a Texas non-profit corporation, and its New Construction Committee (the "NCC"). These Guidelines apply only to single family residential lots in Belterra, and are intended for the use of home builders and their engineering and architectural professionals and contractors. Owners and builders are advised that these Guidelines may not constitute all of the restrictions which may be imposed on a specific lot or parcel of land in Belterra, and the Covenants, as well as all other community governing documents, the deed of conveyance, the recorded subdivision plat and applicable purchase and sale agreement, should be reviewed in detail. Belterra is located within the extraterritorial jurisdiction of the City of Dripping Springs, in Hays County and in various taxing districts, and lots additionally are subject to all matters of record and all applicable city and county agreements and requirements, law and ordinances. It is the intent of the Developer to administer and apply these Guidelines fully and completely in order that Belterra will be developed with a consistency of quality and design, in accordance with prevailing industry standards. These Guidelines also, however, reserve to the NCC flexibility in its review and approval authority, with the associated rights to grant variances and waivers in order to balance competing development issues and priorities, and to accommodate lot and section differences or avoid undo hardship. RESIDENTIAL DESIGN GUIDELINES Doe #.WASO1 (320288M0004) PAGE il P 83 Bk OPR Vol 2218 NEIGHBORHOOD PLANNING ELEMENTS Belterra will be developed with continuity in street, landscape and greenbelt design in order to create a sense of community, and builders will be requires to coordinate their architectural lot, house and landscaping designs and styles in order to conform to community standards. The purpose of this section is to identify those on-lot design and construction elements that influence overall neighborhood appearance. Requirements in this Section Neighborhood Planning Elements are in addition to requirements in other sections. Sidewalks • Homebuilders are responsible for installing sidewalks on one side of dedicated streets, as specified on applicable section subdivision plats. • Sidewalks will be installed within the public right-of-way area between curb and lot line, and will be constructed no less than. four (4) feet in width in accordance with the construction specifications attached to these Guidelines as Schedule 2. • Required handicap curb ramps will be installed by the Developer as part of the installation of streets, in accordance with subdivision construction plans. Street Address Markers Street address markers and/or plaques will be installed on the front elevation of each residence within Belterra, to be designated or approved by the NCC for each community section. Square Footage Subject to any different requirements set forth in a specific purchase and sale agreement, the following minimum and maximum space square footage requirements are in effect: For lots: no less than 1800 square feet and no more than 2800 square feet For 70' lots: no less than 2400 square feet and no more than 3400 square feet For 80' lots: no less than 3000 square feet and no more than 4000 square feet For 90' lots: no less than 3600 square feet and no more than 4600 square feet Lots over 90': no less than 4200 square feet, and otherwise to be specified by the NCC on a case-by-case basis For purposes of these Guidelines, all square footage requirements are square footage of finished space (exclusive of basements, garages and unfinished attic areas) and specified lot widths are on-street lot frontages. BELTERRA RESIDENTIAL DESIGN GUIDELINES Doc #:WASO1 (320288-00004) 41 38374v2;413012003/Tirfle: 17:35 PAGE iii Doc 03014643 OPR Vol 2218 Housing Plan and Elevation Repetition The following specifications control plan and elevation repetitions. • For the same plan, different elevation, on the same side of the street: two (2) lots must be skipped. • For the same plan, different elevation, on opposite sides of the street: one (1) full lot must be skipped. • For the same plan, same elevation, on the same side of the street or on opposite sides of the Street: four (4) full lots must be skipped. • The same plan cannot be constructed on back-to-back corner lots. The foregoing specifications are illustrated on Schedule 3 to these Guidelines. In addition, the distribution of plan types on corner lots and abutting side streets, and the distribution of similar elevations among different builders, will be subject to NCC discretion. The NCC has the discretionary right to reject any plan or elevation as incompatible with design criteria or preferences for Belterra or any area or section of Belterra. Building Setback Lines • Minimum building setback lines are established on the recorded subdivision plats, which should be consulted for applicable front, rear and side lot line requirements; additional set back requirements are established in these Guidelines. • Except as permitted in these Guidelines (or permitted by waiver or variance granted by the NCC for setbacks established by these Guidelines), encroachment upon any established setback by any permanent building improvement is prohibited. For purposes of these Guidelines, houses, detached garages, pools, spas, patios and decks, walks and decorative walls are permanent building improvements for the purpose of determining whether an encroachment exists and, subject to contrary governmental subdivision requirements, retaining walls and landscaping are not permanent building improvements. The NCC has the right to grant waivers and variances of setbacks established by these Guidelines upon demonstrable contribution to the a home design or to the community as a whole. • In order to vary the streetscape, at least 25% of each builder's homes on each Street must be setback at least 4 feet behind the front setback, and a maximum of two (2) homes in a row may be built on the front setback or on the same front line. Schedule 3 to these Guidelines. BELTERRA RESIDENTIAL DESIGN GUIDELINES Doe #:WASO1 (320288-00004) 4138374v2;413&2003/Time:17:35 PAGE iv p Doe Bk OPR Vol 2218 Garage Placement • For 80' wide and larger lots, front loading attached garages will be set back a minimum of five (5) feet from the primary house facade and the NCC shall have the discretionary right to require side loading garages for any model type or lot. • Any third garage to be constructed for any model type will be setback two (2) feet from the other two garage bays. • II a lot side yard is adjacent to a section entry street or collector/loop street, driveways and garages will be located appurtenant to the side yard opposite from the entry street or collector/loop street. • If a lot side yard is adjacent to a greenbelt area or park, any detached garage otherwise permitted by the NCC will be located appurtenant to the side yard opposite from the greenbelt area or park. Utility Easements • Easements for water and sewer, electric, telephone, propane gas, cable television and other utilities and services and matters have been or may be established by recorded documents, including, subdivision plats, the Covenants, the deed of conveyance for each lot, as provided under an applicable purchase and sale agreement or otherwise, and all easements should be identified and located by each homebuilder. • Encroachment upon any easement by any permanent building improvement is prohibited. BELTERRA RESIDENTIAL DESIGN GUIDELINES Doc #:WASO1 (320288-00004) 4138374v24/3(v200alTjme:17:35 PAGEv p 9 Doe Bk 03QJ14643 GPR iii. Vol 2218 SITE MAINTENANCE DURING CONSTRUCTION Each lot in Belterra and its surrounding area shall be maintained during all periods of construction in a neat, clean and orderly condition, subject to such container and disposal requirements as from time to time may be specified by the NCC. Trash will be removed from each lot weekly or as often as reasonably is required in order to maintain a neat, clean and orderly site. Construction debris, including excess concrete, may not be burned, dumped or disposed of in any area of Belterra unless a specific location for such a purpose in writing is approved by the NCC. Appropriate governmental agencies should be contacted for erosion control and other NPDES permits. Covenants. Sediment Control In order to maintain clean streets and prevent siltation of storm sewers and drainage channels, all builders will maintain appropriate sediment controls during construction. All sediment control fencing will be installed in order to direct storm water run-off into streets, parks and greenbelt area. All sediment control fencing will be installed no later than the commencement of earthwork and will remain in place and in good repair until the completion of construction and landscaping. The NCC will have discretionary authority to assess builders the clean-up costs for any failure of any sediment control. On-lot sediment control fencing will be constructed of wire mesh and burlap or a commercially manufactured fencing product securely anchored below grade so that storm water flow passes through the fence material or is trapped behind it. Concrete Wash Out Site Homebuilders will provide a concrete wash-out site on one lot for use during construction and approved by the NCC. An identification sign will be installed on the selected site prior to use. Protection of Adjacent Lots and Greenbelt Areas Work performed in public, common or other open or landscaped areas for any reason by any homebuilder will protect existing grades and trees and vegetation. In addition, adjacent lots and greenbelt areas will be protected by temporary four (4) foot orange safety fencing installed along or parallel with appurtenant lot line lines prior to the commencement of lot clearing. Homebuilders are responsible for the repair and/or replacement of grades, landscaping, sidewalks, street lights, streets and any other improvements or property damaged during construction. Protection of Existing Trees Successful preservation of trees and plant life relies on quality construction methods, including the installation of protective barriers, root pruning, removal of dead, diseased or obstructing branches, avoiding extreme grading and/or altering the drainage patterns, avoiding soil compaction under driplines, and providing supplemental feeding and/or BELTERRA RESIDENTIAL DESIGN GUIDELINES Doc #:WASO1 (320288-00004) PAGE vi P 9 Doe Bk Vol 03014643 OPR 2218 watering. Homebuilders will adopt a conservation plan responsive to attendant circumstances. Temporary Buildings During construction, prior to the completion of a model house, two (2) temporary structures may be installed on-site for a model and sales office and a construction office; after completion of a model house, one (1) temporary structure may be maintained on-site for a construction office. The NCC has the discretionary right to limit the number of temporary construction office(s) maintained for adjacent or otherwise proximate sections and to approve the location, design and appearance of all temporary structures. All temporary structures will comply with all setback requirements, may not be located in public or common areas, and will have access from a paved or temporary gravel right-of-way. Temporary construction structures will be removed from each subdivided section or subsection, at the request of the NCC and after 80% of lots in such section or subsection are occupied. BELTERRA RESIDENTIAL DESIGN GUIDELINES Doe #:WASO1 (320288-00004)41 38374v24138J2003/Time:l 7:35 PAGE vii p Doc Bk I3PR Vol 2218 LOT ELEMENTS IV. Driveways Each homebuilder will install driveways over lots and into street rights-of-way. The NCC has the discretionary right to approve all driveway locations. Concrete driveways are to be a minimum four (4) inches thick. A #6, six (6) inch by six (6) inch woven wire mesh shall be installed within the portion of each driveway within street rights-of-way (between the curb and the lot line). • Driveways may be paved with concrete or unit masonry, including stamped or colored concrete, interlocking payers, brick payers and brick borders, as may be approved by the NCC. Asphalt driveways and paving are prohibited. • Driveways will be located no closer than two (2) feet from the side lot line. • Driveways serving homes with attached side loaded or detached garages will be a minimum of ten (10) feet in width. • Driveways serving attached two car garages facing a Street will not exceed twenty-two (22) feet in width. • Driveway slopes should be uniform with smooth transitions between areas of varying pitch. • The use of circular drives is discouraged except in the discretion of the NCC. Sidewalks Homebuilders are responsible for installing sidewalks on one side of public streets, within the public right-of-way area between curb and lot line, and will be constructed no less than four (4) feet in width in accordance with the construction specifications attached to these Guidelines as Schedule 2. • Locations of sidewalks are not to be varied except where required to avoid existing trees retained by the Developer. • Where sidewalks cross driveways with decorative paving, the sidewalk does not have to be carried through the driveway. • Where sidewalks deviate from a straight line, gentle radii, instead of abrupt curves and angles, will be utilized. BELTERRA RESIDENTIAL DESIGN GUIDELINES Doc #:WASO1 (320288-00004) 4138374v2;4/30/2003frjme• 1735 PAGE viii P 9 Doc Bk. OPR Vol. 2218 • Manholes and valve boxes located within sidewalks will be flush with completed sidewalk elevation. • Exposed edges of sidewalks will be concealed by the final grading of lots. Walks Walks should be a complimentary component of site design and should not compete visually with the house and/or landscaping. • Walks will be at least three (3) feet in width and no more than five (5) feet in width, and will be installed from the front door of a house to the street curb or driveway. • Walks will be constructed of unit masonry, quarried stone or concrete or otherwise as the NCC may approve. Asphalt walks are prohibited. • If a walk is parallel to the front, side or rear elevation of a house, a planting area (a minimum two (2) feet in width) may be required in the discretion of the NCC between the house and walk. • Sidewalks will not be visually or physically broken by an intersecting walk. Retaining Walls • All retaining walls will be constructed of or faced (veneered) with stone, brick, stucco or NCC approved masomy alternative. • Unless approved by the NCC in its discretion, retaining walls adjacent to or visible from any Street shall not exceed 4' in height. If applicable grade exceeds 4', then the NCC shall have the additional discretion to require terracing such that a series of retaining walls no higher than 4' each be separated with a minimum of 4' clear separation between each wall. • Retaining walls will be designed as an integral part of the lot and house design. Masonry that matches house exterior materials will be encouraged. On-Lot Fencing In accordance with Developer/builder purchase and sale agreements, homebuilders will reimburse the Developer, on a linear foot basis, for on-lot project fencing abutting dedicated rights-of-way and greenbelt area(s) of Belterra. Preliminary locations for and the construction types of such fencing are described on Schedule 4 attached to these Guidelines. The Developer has reserved the discretionary right to modify and amend the locations and construction types for any such project financing, although reimbursement charges payable BELTERRA RESIDENTIAL DESIGN GUIDELINES Doc #:WASO1 (320288-00004) 4138374v2;4/30/2003fTime: 17:35 PAGE ix Pu 94 Doe Bk Vol OPR 2218 by purchasers are limited on a linear foot basis for specified construction types. Each homebuilder will be responsible for installing on-lot fencing as follows. • The homebuilder will be responsible for installing a fence along the rear and side lot lines of each lot, with a fencing style and materials in the discretion of the NCC. • The NCC will have the discretionary right to establish separate standards for neighborhoods containing custom or estate homes. • Fence siding facing the public will be the "finished" side. • All fencing is to be staggered or stair-stepped down slopes, with the tops of fences level with the horizon and height levels changed at normal column/post spacing. Fences running parallel to the slope are not acceptable. Typical Interior Lot Typical interior lots will be fenced with western red cedar or treated pine wood fencing six (6) feet in height and in accordance with the specifications set forth on Schedule 5. Fences will be installed with alternating seven (7'-8' ) foot panels and exposed rails along common interior lot lines to provide a uniform appearance to each abutting lot. Typical Corner Lot • On-lot fencing located on the exterior side of a lot adjacent to the street will be an upgraded wood fence with a trim cap in accordance with the specifications set forth on Schedule 5. The trim cap will consist of western red cedar two (2) inches by six (6) inches, and trim cap joints will be mitered at 45 degrees. • Upgraded wood fencing will be installed live (5) feet from the Street right-of-way line, from the rear lot line running parallel to the street, past the rear elevation of the house to the front elevation line of the house, and returning into and connecting with the house. • The NCC has the discretionary right to require masonry columns to be incorporated into upgraded wood fencing as shown on Schedule 5. Outdoor Lighting Outdoor lighting will conform to the following standards and be approved by the NCC. • • Floodlight fixtures will be attached to the rear of houses and detached garages. Floodlights will not illuminate areas beyond limits of lot. BELTERRA RESIDENTIAL DESIGN GUIDELINES Doe #:WASOI (320288-00004) PAGE x Doc Bk OPR Vol • Ornamental or accent lighting is permitted, but should be installed in moderation and should be complimentary to primary design elements. • Moonlighting or uplighting of trees is permitted, but the light source will be hidden. • Colored-lenses on low voltage lights, colored light bulbs, and fluorescent andneon lighting are prohibited. • Mercury vapor security light fixtures visible from public view or from other lots are prohibited. Mercury vapor lights, if used for landscape lightingaffect (such as hung in trees as up and down lights) are permitted. Screening All air conditioning compressors, and any other mechanical or electrical devices, pool equipment, garbage containers or other equipment will be screened by appropriate fencing, decorative walls, landscaping or a combination of the foregoing. If screening is by landscaping, complete screening will be accomplished with initial material installation, rather than achieved with growth at maturity. Landscaping and Trees The residential lot builder is responsible for the installation of landscaping and trees in all front yards, including the portion of the Street right-of-way between the property line and the Street curb and, as specified, installing supplemental trees or landscaping on side yards of corner lots and rear yards of adjacent greenbelt lots. Installation of all landscaping and trees must occur prior to occupancy of the house or within 30 days after substantial completion of construction, whichever occurs first. Installation of landscaping and trees, including materials and worlunanship, must be in conformance with acceptable industry standards. On-lot Landscaping • Minimum planting bed specifications include: a. Minimum planting bed width of three (3) feet from house foundation. Curvilinear planting beds are encouraged; • b. The number of plants utilized shall be appropriate for the size of the planting bed, although a minimum of five (5) different species of plants will be used within front yard planting beds; and c. Front yard planting shall include a minimum of 10 larger species (minimum five (5) gallon) and 15 smaller species (minimum one (1) gallon). Planting bed edging is not required, but is encouraged for maintenance purposes and to define the shape of planting beds. Plastic, corrugated aluminum, wire wicket, BELTERRA RESIDENTIAL DESIGNGUIDELINES Doc #:WASOi (320288-00004) 7:35 PAGE xi Doc Bk 03014643 OPR Vol 2218 railroad ties, etc., are not in character with the desired landscape effect and are prohibited. Acceptable edging is iyerson steel, brick and stone. • All planting beds are to be mulched. • The use Of gravel or rock in front yard planting beds is prohibited, exceptas a border when set horizontally or utilized for drainage purposes. Specimen boulders are permitted. • St. Augustine grass is prohibited. • The front lawn of each completed house and side yard of corner lots (outside the fence) and areas between curb and sidewalk shall be completely sodded with either Bermuda Tif 419, JaMur Zoysia, El Toro Zoysia or 609 Buffalo Grass. Seeding and/or sprigging is prohibited. • To maintain sight line corridors, shrub heights within the street R.O.W. must not exceed thirty (30) inches in height at maturity. • The rear yard of each greenbelt lot shall be planted with a sufficient amount of shrubs so as to completely screen all house and garage foundations. • All landscaping is required to be maintained in a healthy and attractive appearance. Proper maintenance includes: a. b. c. d. e. f. g. h. i. Adequate irrigation, automatic irrigation systems are encouraged; Appropriate fertilization; Pruning; Mowing; Weed control in lawns and planting beds; Seasonal mulching of planting beds; Insect and disease control; Replacement of diseased or dead plant materials; and Initial warranty of all planting materials. • Integrated Pest Management Practices for Turfgrass, Termites, Rodents, Fleas and Fire Ants are attached to these Guidelines as Schedule 6. • Water and energy conservation recommendations are attached to these Guidelines as Schedule 7. BELTERRA RESIDENTIAL DESIGN GUIDELINES 0cc #:WASOi (320288.00004) 4l38374v2;4/3Y2003iTime1 7:35 PAGE xii P 9 Doe Bk OPR Vol 2218 P 9 Trees • Tree planting between sidewalk and streets is prohibited (except for existing trees preserved by developer). • A minimum of two (2) trees (existing trees or as designated on Schedule 8) must be planted in front yards. Each tree must be a minimum three (3) inch caliper measured in accordance with the Texas Association of Nurserymen Grades and Standards at the time of planting, and minimum tree height for the three inch caliper tree is twelve (12) feet. • Front yard trees should be planted in an informal manner to promote a more natural look. There should be a mix of tree species. • One of the two (2) required front yard trees (1) will be planted between 12 feet and 20 feet beyond theback of curb of each lot and within 15 feet of the center of the lot. The same Street tree shall not be used more than two (2) lots in a row. At least every Schedule 8 attached to these Guidelines. other street tree should be evergreen. • For corner lots, two (2) additional trees will be planted, each a minimum of three (3) inches in caliper and twelve (12) feet in height, and to be located between 12 and 20 feet beyond the back of curb, spaced at least 30 feet from the center of the side lot Schedule 8 attached to these Guidelines. line and separated by at least 60 feet. Master Plant List Two plant lists, a front yard Street tree list and a master plant list, are provided as attached Schedules 6 for assistance in selecting species. The plants listed are generally suitable to conditions in our zone, however, in selecting plants from this list, careful consideration should be given to their cultural requirements as compared to the particular climate conditions. Any soil, water or other tests necessary to determine the existing conditions on a particular site are the responsibility of the individual homebuilder. BELTERRA RESIDENTIAL DESIGN GUIDELINES Doe #:WASOI (320288-00004) 4138374v2;4130/2003ITime:1 7:35 PAGE xiii Doc Bk 03014643 OPR Vol 2218 HOUSING V. This section establishes basic requirements and criteria for home construction. Developer emphasis is on quality in material, design and construction in order to promote well crafted homes within the various communities of Belterra. These guidelines allow for diversity in design, with an intent to produce a sense of individuality, while insuring architectural integrity of the community as a whole. Foundations Prior to foundation construction, an area soils test should be undertaken to ensure foundation quality. • Prior to foundation construction, a form survey should be undertaken to ensure that building setback lines will not be violated. • All foundation plans must be signed and sealed by a Texas Registered Professional Engineer. Minimum slab elevations are detennined by and should be coordinated with the appropriate county agency. • Exposed foundations shall be limited to 12" height on front elevations, as well as all other elevations facing streets. The height of exposed foundations is limited to 18" on interior side elevations and 30" on rear elevations. • Exposed foundation should be minimized by dropping the masonry course. The masonry ledge must extend around building corners a minimum of two (2) feet before stepping up or down to a less restrictive foundation requirement. The step up/down should relate to some architectural feature (such as lining up with a window or change in wall direction). • Backfill around slab creating an unnatural finished grade condition is not a permitted means to reduce exposed foundations and are not pennitted. • Masonry planters permissively may be used in front of exposed foundations for visual screening. Planters must be of matching or compatible building material. Exterior Materials Single-family homes within production and custom neighborhoods of Belterra must be 100 percent masonry up to eaves (excluding pennitted facade and other architectural detailing), except that: BELTERRA RESIDENTIAL DESIGN GUIDELINES Dec #:WASO1 (320288-00004) 4138374v2;4/30/20031flme:17:35 PAGE xiv P Doe Bk 03014643 OPR Vol 2218 • Interior lots having a common rear lot line with another interior lot (other than corner lots and lots adjacent to a greenbelt area or park) may have second story interior side elevations and rear elevations of hardiplank; and • All lots may have second story rear elevations of hardiplank. Changes in materials should have a logical relationship to changes in form, and no more than two different building materials shall be permitted on the front elevations unless otherwise approved by the NCC. Samples of all exterior building materials must be submitted to the NCC for approval. Exterior building materials for all homes within Belterra must comply with the following standards and guidelines. • Stone: The use of any natural or synthetic type of stone on the exterior of a residence must be approved by the NCC to ensure architectural compatibility within the section and the community. • Brick: All brick used on homes in Belterra will meet standard specifications established by the Brick Institute of America (Selected Standards For Brick compiled by the American Society for Testing and Materials under designation C216-87). The same brick selection (manufacturer and color) may not be used on adjacent homes. Approved brick manufacturers and color from time to time will be specified by the NCC. See also "Exterior Color Schemes" at page 18. • Wood: All wood used on houses must be painted or stained, naturally weathered wood is prohibited. If a stain is used, a wood sealant must be utilized. • Hardiplank: Where pennitted, hardilpiank will be horizontally installed, single faced, cellulose fiber-reinforced cement building strip siding conforming to specifications as listed in the National Evaluation Service, Inc., National Evaluation Report No. NER-405, reissued January 1, 1999, for Hardiplank and comparable in appearance and durability and warranty to Hardiplank. • Trim: All wood trim shall be smooth, high quality finish-grade stock, stained or painted as approved by the NCC. • Stucco: Unless express NCC variance is granted, stucco may be used as an exterior accent finish only and not a primary facade material. Stucco accent finishes will be consistent with the architecture style of the home and uniform in color with other exterior housing materials. • Metal: Exposed metals shall be anodized aluminum, bronze, copper or painted galvanized steel. BELTERRA RESIDENTIAL DESIGN GUIDELINES Doc #:WASO1 (320288-00004)41 38374v2;4130/200amme 17:35 PAGE xv Pu Doe Bk 03014643 OPR Vol 2218 p 10 Facade Design • Entrances to dwellings will be clearly defined, protected by a covered porch and integrated with the building design. • The use of recessed windows and the expression of columns and beams that create shadow and texture are encouraged to establish a sense of residential/pedestrian scale. • Break up the elevations to provide shadow relief. Use recessed areas, offsets, etc. to create interest. Consider offsets where roof lines change. Window Treatment • Wood or metal windows may be used. When metal windows are used the finish shall complement the color and architectural style of the house. • No reflective glass or glazing will be allowed on any front or side facade, or on any facade which is visible from a public street or greenbelt area. • The use of wrought iron ornamentation on the exterior of any window is prohibited. Roof Treatment; Materials • Roofing materials used on all homes will be no less than [to specify weight and rating minimum], dimensional single, black, gray or approved neutral color. Three high and wood shingles are prohibited. • A range of roofing tones and colors in sections is encouraged in order to avoid monotony. • The use of alternate roofing materials (such as clay, slate, tile or metal) is limited to estate lots, with the approval of the NCC, except, that, the use of such alternate materials as an architectural element (i.e., over porches, on bay windows, etc.) is permitted for all homes. Chimneys • All fireplace chimneys located on the exterior of a dwelling shall be constructed of masonry, hardiplank, stucco or approved substitute. Prefabricated metal fireplaces and metal flues may be used, but chimneys will be masonry clad to appear as traditional masonry chimneys. • All estate lot home chimneys will be constructed of masonry or stone. BELTERRA RESIDENTIAL DESIGN GUIDELINES I3oc #:WASO1 (320288-00004) PAGE xvi Doc Bk 03014643 OPR Vol 2218 Exposed Roof Metal All exposed metal roof accessories, stack vents, roof flashing, attic ventilators, etc. shall match roofing material color. All stack vents and attic ventilators shall be located on the rear slopes of roofs and mounted perpendicular to the ground plate. In cases where metal roofing is approved, roof accessories may be made of the same metal. Skylights and Solar Collectors The NCC will approve the location and design of all skylights and solar collectors. No solar collectors will be allowed on any roof slope visible from a public street, corner lot or greenbelt area Rain Gutters and Drains All roof systems will be designed with rain gutters and drains that will be integrated with the architectural house design in color, size, shape and location. The use of a splash pad or hidden drain pipe is required. Garages • Garages may not exceed in height or number of stories the main dwelling on any lot. • Carports are prohibited. • All garages at a minimum will accommodate the storage of two (2) full size automobiles at the same time. An extension in the width or length of a garage to permit storage space may be submitted to the NCC for approval on a case-by-case basis. • All garage doors should be of approved material and design, in a color to complement the adjacent wall and trim. • Designs incorporating side or rear entry garages are encouraged to break up the monotony of multiple garage doors facing the Street. • Windows may be required on the facade of side or rear loaded attached garages. • Setback of the garage from the facade of the house is encouraged to diminish the effect of garages on the Street scene. • Detached garage exteriors must be constructed of the same materials and have the same architectural style as the main dwelling. • Garages will be constructed as garages and will not be converted to living or working space (with the exception of model homes). BELTERRA RESIDENTIAL DESIGN GUIDELINES Doc #:WASO1 (320288-00004)41 38374v2;4/30/2003/Time: 17:35 PAGE xvn P Doc Bk OPR Vol 2218 Dwellings on corner lots will be oriented so that garages are located adjacent to the interior lot property line (away from the street corner). Side entry garages on corner lots will be placed at the side of the house opposite from the street corner. Twin single garage doors are preferred to one large double door. Designer-style garage doors are encouraged with the intent of giving the Street scene more architectural interest. Exterior Color Schemes All exterior colors must be submitted to and approved by the NCC. The palette of exterior colors for each residence will be selected to complement, coordinate or harmonize with the colors of building materials used in their natural state, such as brick, stone, copper, etc. The use of pastçl and primary colors, and red, orange and pink brick, is strongly discouraged and may be used only by special approval of the NCC. Paints or stains should be limited to three (3) complimentary colors per lot. Pre-Wiring of Homes All builders are required to pre-wire homes with Category 5 wiring. Mechanical Equipment All air conditioning compressors, power and meter boxes, and any other mechanical or electrical devices and poo1 equipment, will be completely screened from public view by appropriate fencing, decorative walls, landscaping or a combination of the foregoing. Plants for landscaped screening will be no less than 3' in height upon installation in order to provide immediate screening. Maintenance • Each home and lot will be maintained in a neat, clean, orderly condition by the builder/owner prior to the sale and occupancy of such home. Periodic repairs shall be made to correct any condition, which suggest visual deterioration of a home or lot. • Each homeowner is required to maintain all landscaping within the right-of-way located on lot, between the edge of curb and house, except for improvements that may be the maintenance responsibility of the Belterra Homeowners' Association, Inc. BELTERRA RESIDENTIAL DESIGN GUIDELINES Doc #:WASO1 (320288-00004) 4138374v2;4130/2003ITime:17:35 PAGE xviii p Doe Bk 03014643 OPR VI. Vol 2218 MODEL HOME PARKS/SALES CENTERS The location of all proposed model homes and sales centers must be approved by the NCC. Proposed sites will be reviewed on a case-by-case basis and no specific criteria accordingly is specified, except the following: • Project phasing should be considered when establishing model units, and additional sites should be identified to accommodate future sections or product lines or changes in market strategy. • Lots on short cul-de-sacs or "bubble" streets located off of the main entrance street to a neighborhood serve as excellent sites for model homes. These lots not only provide a clustered setting for the model homes but permit neighborhood main entrances to maintain an open and uncluttered appearance. • Temporary exceptions related to non-standard driveways, sidewalks, lighting, flags• and flagpoles, signs or other marketing techniques will be considered by the NCC on a case-by-case basis. • Sign age for model homes shall be subject to applicable County regulations, if any, and to the approval of the NCC on a case-by-case basis. VII. SIGNAGE The Developer will have discretionary authority for all community and directional signs in Belterra. The NCC will have discretionary authority over all sales, model and section signage. BELTERRA RESIDENTIAL DESIGN GUIDELINES Doc #:WASO1 (320288-00004) 4138374v2;4/30/2003flime:17:35 PAGE xix Doc Bk 03014643 CJPR Vol 2218 DESIGN GUIDELINES SCHEDULES: Schedule 1 Schedule 2 Schedule 3 Schedule 4 Schedule 5 Schedule 6 Schedule 7 Schedule 8 Conceptual Plan Sidewalk Construction Specifications House PlanfElevation Repetition and Setbacks Developer Installed On-lot Fencing Builder On-lot Fencing Specifications Integrated Pest Management Practices Water and Energy Conservation Recommendations Street Trees and Approved Trees and Landscaping Materials BELTERRA RESIDENTIAL DESIGN GUIDELINES Doc #:WASCJ1 (320288-00004) 4138374v2:4130120031Thne:17:35 PAGE xx P 10 Dcc Schedule I Conceptual Plan Bk OPR Vol 2218 P 10 Doc Bk OPR Vol 2218 108 Schedule 2 Sidewalk Construction Specifications 4, "idewalk STEEL DOWEL CONTROL EXPANSION JOINT MAY BE FORMED WITH REDWOOD OR PREFORMED EXPANSION JOINT SAND LEVELING BED SUBGB.ADE ONE END OF DOWEL AT1B"O.C. OREASE& CAP LONG X6"#lOWWM MATERIAL INSTAlL WITH 'ZIP STRiP' OR lxi WOOD STRiP AT SURFACE TO LEAVE A VOID FOR. ThE JOINT SEALEL ON CENTER UNLESS NOTED OTHERWISE ON PLAN. 2. EXPANSION JOINTS ARE TO BE ON PLAN. 3. CONTROL JOiNTS ARE TO BE 4' ON CENTER UNLESS NOTED 1. NOTES BELTERR..A / 1X4 REDWOOD OP. PREFORMED EXPANSION JOINT MA WrrH BACKER ROl EXPANSION JOINT POLYSULFIDE SEALER. BROOM SCALEt - Dcc, Bk 03014643 OPR Schedule 3 House PlanIElevation Repetition and Setbacks 2218 Pu _IT Bk OPR Vol 221i p 11 SAME PLAN. DIFFERENT ELEVATION. OPPOSITE SIDE OF STREET SAME PLAN, DIFFERENT SAME SIDE OF SAME PLAN, SAME ELEVATION, SAME 0R OPPOSITE SIDE OF STREET NOTE ThESE ARE IOR BELTERRA House Plan/Elevation Repetition ONLY. EXHIBIT — NOT TO PALE R.EAR YARD Setbacks BELTERRA SETBACK I I I I I I — NOT TO SCALE B1O}rr.o1.wAY L NC Bk Vol 03014643 (PR 2218 Schedule 4 Developer Installed On-lot Fencing p 1 FOOTING 3000 P.S1. CTYPICAL) POST 18W DEPTH INTO cONCRETE. DIA. CONCRETE COLORS TO BE DETER}4INED BY DEVELOPER.. FENCE BOARDS TO BE NO, i, X 6W CAP & ROT BOARD TO BE NO. 1 ROUGH SAWN CEDAL ALL RAILS TO BE PRESSURE TREATED PIN!. POSTS TO BE 2-3/8W DIA, 18 GA. GALVANIZED STEEL POSTS GALVANIZED PIPE TIPS (SIMPSON SI'RONGTIB POT 2 OR TRIM FASCIA, & ROT BOARDS TO BE JOINED @ 45 ANGLE. USE NAILS TO ATTACH PENCE BOARDS TO STRINGER . 2 PER BOARD AT EACIi USE COATED SCREWS TO ATTACH FASCIA AND ROT BOARDS TO TOP & BOUOM STRINGER. MAX 16W O.C. STREET SIDE OF PENCE TO BE FINISHED WITH OPAQUE STAIN, FASCIA, Upgra Wood Fence BELTERRA 7) 6) 4) 5) 2) 3) 1) NOTES BOARD TO STAY PAP.ALLEL TO FINISHED GRADE FENCE DOWN WHERE NEEDED TO_MAINTAIN OVERALL HEIGHT Masonry Column at Upgraded Wood Fence BELTERRA UPGRADED WOOD REFER TO cCLUMN TO FACE ADJACENT ROAD CL PENCE CAP EQUALLY SPACED • #4 REBAR LOOPS •STONE VENEER TO WELOOME CENTER & ENTRY MONUMENT SCALL 3/r — EXHffirr!{ FOOTING 3000 P451. (TYPICAL) E'C.TEND POST 18" CONcRETE. DIA. cONCRETE OP cONCRETE X 6' ROT BARD X 4' VERTICAL PENCE BOARDS TO BE NO.1, 1" X 6' TREATED CEDAR. CAP, FASCIA, & ROT BOARD TO BE NO. 1 ROUGH SAWN CEDAR.. ALL RAiLS TO BE PRESSURE TREATED PIN!. POSTS TO BE 2-3/8' DIA., 18 GA. STEEL POSTS WITH PIPE TIES (SIIYIPSON STRONOTIE POT 2 OR SIMU.AB). TRIM CAPS PASCLA. & ROT BOARDS TO BE JOINED @ 45 ANGLE. USE NAiLS TO ATTACH PENCE BOARDS TO STRINGER . 2 PER. BOARD AT EACH STRINGER. USE COATED SCREWS TO ATTACH PASCIA AND ROT BOARDS TO TOP & BOTTOM STRINGER. MAX 16' O.C. STREET SIDE OF FENCE TO BE FINISHED WITH OPAQUE STAIN, COLORS TO BE BY DEVELOPER. Upgraded Wood Fence with Gate 7) 6) 4) 5) 2) 3) 1) NOTES TIE TO TO POST FOR HINGES SCALPA 3/P — EXHIBIT — Z'X4' INTERIOR CORNER PIPE OR!? USE SUYfPSON STRONOTIE O.C. CONCRETE. ,—12' DIA. CONCRETE FOOTING 3000 P.S1. (TYPICAL) POST 30' DEPTH INTO TOP OF CONCR.ETE X 1.1/2' BASE RAIL 2' SQ. POST AT 41/2' PICKETS X 14/2' CAP RAIL 3/4' SQ. RAIL 1.1/2' Ornamental Steel Fence for Greenbelt BELTERRA '.., -. - CAP ALL. FENCES TO BE BLACK POWDER COAT PAINT FINISH. NOTE. X 14/2' BASE RAIL SCALEi 3/8' • EXHIBIT — X 1.1/2' roc —Q Doc Bk OPR Schedule 5 Builder On-lot Fencing Specifications Vol 2218 P TOP OP CONCRETE CEDAR BOARD 4' TREATED POST DIA. CONCRETE FOOTING 3000 POST 18" DEPTH INTO x CENTERLINE POST Standard Residential Wood Fence :'j - COVER CENTER BOARD TO 8' MAXIMUM TREATED CEDAR, NOTCHED TOP. ALL WOOD TO BE PRESSURE TREATED PINE. ADD VERTICAL SUPPORTS, RCSSBRACINQ, & METAL PLATES AS REQUIRED POP. LONG TERM SrRUCTURAL DTrEGR1TY. USE Sfl4PSON STR.ONG.TIE HANGER #FB24 (OR SIMILAR) TO ATFACH RAILS TO POSTS. PENCE PANELS TO ALTERNATE, ONE TOWARD OWNER, NEXT TOWARD NEIGHEOL ETC. POsTS TO BE EQUALLY SPACED ALONG A CONTINUOUS STRETCH OF FENCE. 8 MAXIMUM POSTS. VERTICAL PENCE BOARDS TO BE NO.1,r X 4' BELTERRA 6) 5) 4) 2) 3) 1) NOTE& 1 . _I I I I X 4' VERTICAL I STRINGER Ii - 2" X 4' HORIZONTAL 8' MAXIMUM F I LI' V.0' —c .wx. 3000 PS.L POST 18' DEPTH cONcRZTE DIA. TOP OF X 4' VERTICAL X 4' CEDAR. X 4' TREATED POST TO ATFACH RAILS TO POSTS TREATED CEDAR4 NOTCHED TOP. ALL OTHER WOOD TO BE PRESSURE TREATED ADD VERTICAL CROSSBBACINO, & METAL PLATES AS REQUIRED POP. LONG TERM STR.UCrURAL INTEGRiTY. USE SIMPSON STRONGTIE HANGER #F324 (OR S!M]LAR) VERTICAL FENCE BOARDS TO BE NO.1,1' X 4" Standard Residential Gate BELTERRA p4 4) 2) 3) 1) NOTE& -USE 3 PER GATE BLOCK AS NECESSARY 3/r • r.o' HARDWARE TO BE BLACK HEAVY GAUGE METAL TO POST SPACNQ AS REQUIRED FOR Doc Bk OPR Schedule 6 Integrated Pest Management Practices Vol 2218 Pu 12! Doc 1PM PLAN for 03014643 Bk OPR Vol 2218 TURFGRASS (6/26/00) 1. Pests to be controlled: turfgrass weeds, diseases, and insects 2. Integrated Pest Management (1PM) of turfgrass involves the use of multiple control tactics to keep selected pests nelow an acceptable injury level. 1PM has a series of responsibilities, the primary one being the proper identification and understanding of the pest. Selected pests are only those which pose a threat to turf quality. Common turfgrass pests are weeds (including crabgrass, and dallisgrass), diseases (including brown patch, dollar spot, and pythium blight), and insects (including fire ants, webworms, and annywonns). mole crickets, The tactics included in this 1PM plan are: a.) physical, b.) cultural, c.) biological, and d.) chemical. The goal of the 1PM plan is to emphasize the physical, cultural and biological tactics and minimize chemical use, thereby lessening the effects on the hydrologic system. • 3. Life cycle of pests: Crabgrass (Digitaria app.): Crabgrass is an annual grass spread primarily by seed and to a minor extent by rooting from lower nodes. Crabgrass is a short, bunching, grass, light green in color. It is frequently found in over-watered turf and/or compacted soils. b. Dallisgrass (Paspalum dilatatum): Dallisgrass is a warm-season annual grass. It is a coarsetextured, bunch-type grass that spreads primarily by seed. Lower leaves may be hairy, while all are noticeably shiny. The seed stalks of dallisgrass are sparsely branched on long stems, and contrast dramatically in desired turf. c. Brown Patch (Rhizoctonia spp.): Brown patch is a fungal disease most likely to damage bermudagrass and St. Augustinegrass in the spring or fall. Areas of turf affected with brown patch consist of irregular brown areas that range from a few inches to many feet in diameter. Environmental conditions that favor disease development are day temperatures above 85°F, high relative humidity, and prolonged overcast wet periods. Excessive nitrogen fertilization and frequent irrigation also favor development. d. Dollar spot (Sclerotinia homoeocarpa): Dollar spot in turf consists of small circular areas about 2 inches in diameter, which are brown or straw in color. Moderate temperatures (60° to 80° F), excess moisture and excess thatch lead to development of this disease, especially on closely cut a. e. p 12 Pythium blight (Pythium spp.): Pythium blight kills turf in small irregular spots. The fungi produce spores that survive for long periods in the soil, but develop rapidly with excessive moisture. Blackened leaves of affected grasses wither rapidly and turn reddish brown. At high temperatures, severe damage can occur in low areas of consistently wet turf. f. Fire ants (Solenopsis invicta): The red imported fire ant is a tropical insect that was accidentally introduced into the United States in the 1930's. Fire ants disperse naturally through mating flights, which usually occur in the spring and fall. Fire ants are often moved in soil, sod, and containerized plants. Fire ants do not attack turf, but cause problems when they build earthen mounds for warming their eggs, larvae, and pupae. Mounds may be built in any turf situation. Established colonies produce new queens and workers that, if left uncontrolled, will eventually lead to large populations and additional mounds. Refer to the individual 1PM plan on fire ants for specific control measures. g. Mole crickets (Scapteriscus acletus): Mole crickets have grayish brown, velvety bodies with broad spade-like front legs adapted for digging. Adults spend the winter in deep burrows. When the soil warms, they move up to dig in grass and feed on turf insects. In the late spring and early summer, mole crickets fly and mate. Females lay eggs in chambers beneath the soil. The eggs hatch in May and June, with any tunneling caused by the young nymphs obvious by late July. Doc 1PM PLAN for Bk OPR Vol 2218 p TURFCRASS (6/26/00) The most vulnerable stage of the mole cricket is the nymphal stage with earlier treatments ineffective. Treatment will be made only if damage is noticeable and verified by a soap flush. A proposed injury level is 3 nymphs per square feet. h. Sod webworms (Crambus spp.): Sod webworms are the larval form of lawn moths. Larvae are slender grayish, black-spotted caterpillars about 3/4 inch long. Adults are small and vary in color from white to gray. Moths hide during the day, but after mating, drop their eggs over grass at dusk. Eggs hatch in a few days and larvae begin to fee. They pupate in silken tunnels found in the soil/thatch layer. There are 2-4 generations a year with the last spending the winter in the larval stage. Grasses are most susceptible July through September. The presence of larvae is verified by a soap flush with a proposed injury level set at 15 or more per square yard. i. Armyworms (Psuedaletia spp.): Armywonns are the larval form of moths and thus have complete life cycles with eggs, larvae, pupae, and adults. They are dull brown, tinged with red, and thickbodied. Adults fly at night and lay eggs at the base of grasses or nearby plants. Arrnyworms feed at night, hiding in thatch during the day. Generations overlap, with as many as six generations a year. The presence of armyworms is verified by soap flush with a proposed injury level set at 5 per square feet. 4. Control tactics: Physical control tactics include simply removing the pests by hand, trapping, or mowing the pests. Weeds can be physically removed with the help of hand-tools. b. Cultural control tactics are those that maintain the quality of turfgrass by providing the best possible growing conditions. These practices are constantly monitored, evaluated, and adjusted for their direct effect on turf quality and the reduction of pest populations. To achieve quality turf grass, and minimize the need for synthetic fertilizer and pesticides, the following practices will be used: 1.) Irrigation: The goal with turfgrass irrigation should be to maximize the efficient use of water and minimize any irrigation runoff If an automatic irrigation system is used, it should be visually monitored while in use on a regular basis. Spray heads should be adjusted to prevent over-spray onto pavement, and any broken heads should be fixed promptly. Overwatering can lead to turfgrass disease; therefore the watering schedule should be adjusted regularly to fit the prevailing weather conditions. Irrigation at dawn allows for drying of the leaf surface before nighttime, thus minimizing the opportunity for disease. 2.) Mowing: Mowing should occur on a regular basis, and no more than one-third of the leaf blade should be removed at a time. Grass clippings should not be bagged, and any grass clods resulting from mowing should be scattered. Clippings will return nitrogen back to the soil as they decompose, minimizing the need for fertilization. To minimize the opportunity for plant disease, avoid mowing wet foliage, keep mowers adjusted and blades sharp. Maintain a high mowing height within a species' adapted range. Raise the mowing height during periods of environmental stress or disease outbreaks. Weeds should always be mown before seed is produced. 3.) Top dressing: Top dressing (spreading a thin layer of compost or other organic matter on the turf) is an effective way to fertilize the soil and control thatch. Control of thatch will reduce the chance for disease and improve water filtration. Thatch is a layer of dead leaves and stems held together by grass roots and stolons. Though a thin layer of thatch seems to be beneficial to the growth of turf, thick layers can cause the turf to grow aboveground and can contribute to disease and insect problems. Thatch can severely restrict the movement of pesticides. Top-dressing with compost may reduce the severity of certain plant diseases. a. Doc 1PM PLAN for Bk OPR Vol 2218 TURFGRASS (6/26/00) 4.) 5.) 6.) 7.) 8.) c. Aerification: Aeriflcation is the process of dc-compacting the top few inches of soil by removing soil cores or simply punching holes into the soil. This practice increases water infiltration, relieves soil compaction, and accelerates decomposition of the thatch layer. Fertilization: The nutrient requirements of turf grass vary with the amount of organic matter in the soil and the amount of water received. The amount and frequency of fertilizer use will be dependent on an analysis of the soil. A 3-1-2 ratio of macronutrients (N-P-K) is usually best. Granular fertilizers will be slow-release (a.k.a. timed-release). Top-dressing with organic fertilizer is ideal. Slow-release and organic fertilizers shall be lightly to incorporate the nutrients into the soil and make them less available for runoff. Fertilizers shall not be shall not be applied during wet weather or when rainfall is imminent applied within any environmentally sensitive areas, or within 50' of a waterway. Overseeding: Overseeding of turfgrass with a cool-season grass while the warm-season grass is dormant may inhibit weed germination. Disease-resistant species: Plant disease-resistant species and cultivars whenever possible. Recommendations for regionally adapted cultivars can be obtained from most Cooperative Extension Service offices. Night lighting: Since the adults (moths) of sod webworms and armyworms are attracted to lights at night and they oviposit nearby, place lights away form sensitive turf areas. Lights with the yellow range are also much less attractive to night flying insects. Biological control tactics for fire ants will include the use of nematodes. Nematodes (Neopleotana Carpocapsae), which are slender, microscopic, unsegmented worms, may be applied over the turf during the warm season to control soil dwelling insect pests. Best results are obtained by applying the nematodes in the late afternoon, just before sunset. Insect Active Ingredient(s) Product Name I Fire Ants d. Neopleotana Carpocapsae ANTidote® Chemical control tactics may include the use of herbicides, fungicides, and/or insecticides. The user shall be a qualified applicator, shall read the product label, and shall strictly follow manufacturer's directions. Chemical control of weeds will be limited to spot treatment with the use of a non-selective post-emergence herbicide. Pre-emergence herbicides will not be used. The use of each chemical will be re-evaluated every year so that the most effective and most environmentally sensitive products will be used. 1.) Herbicide List: Weeds Active Ingredient Product Name Crabgrass Glyphosate Roundup® Dallisgrass Glyphosate Roundup® P Doc Bk OPR VI 1PM PLAN for TURFGRASS (6126/00) 2.) 3.) 5. Fungicide List: Disease Active Ingredient Product Name Brown Patch Propiconazole Banner® Dollar Spot Propiconazole Banner® Pythium Blight Metalaxyl Subdue® Insect Active Ingredient(s) Product Name Mole Crickets Fluvalinate Mavrik® Sod Webworms Bacillus thuringiensis (BT) Dipel® Armyworms Azadirachtin Turplex® Insecticide List: This 1PM plan is a dynamic document. If other control tactics are found effective, then this plan will be amended to include those tactics. No regularly scheduled pesticide applications are planned. Please note that no endorsement of named products is intended, nor is criticism implied for products that are not mentioned. * UI7C Bk 03014643 OPR eaiii 1PM PLAN for TERMITES (6/26100) 1. Pest(s) to be controlled: termites. 2. Biology of the eastern subterranean termite, Reticulitermes flavipes: Subterranean termites are social insects that live in colonies of winged reproductives, sterile workers and soldiers. Overcrowded conditions prompt reproductives to swann, usually during the first warm humid days of spring. Winged termites are often confused with ants but their equal-sized pair of wings can identify them. It is. important that a positive identification be made of suspected termite infestations. Subterranean termites are different from other termites in that they must have regular contact with moisture. This is generally accomplished by building earthen tubes to the soil. Water leaks in structures provide a good enviromnent from which termites can build tubes. In most structures, these tubes are visible on exterior walls, but they may be present on interior walls as well if termites have gained access through cracks in slabs. The important first step in a termite control program is the elimination of conditions that favor termite survival. These steps include the removal of wood debris around structures, eliminating areas of earth-to-wood contact and constructing barriers to termite entry. It is also important to regularly monitor structures for signs of moisture, damaged wood, or earthen termite tunnels and to act only if these signs are present. The most vulnerable stages of the termite colony are the eggs and immatures. 3. Control tactics: a. Physical control tactics will include the plugging of cracks and crevices in structures that may provide access. Any exterior feature that leaks water such as guttering and water pipes will be repaired. Physical controls also include the use of a stainless steel wire mesh perimeter barrier around the building. Installers should be trained and accredited for quality control. Product Name Material I 316 marine grade stainless steel w/appropriately-sized aperture b. There are no mechanical control tactics currently available to control termites. However, sand barriers have been tested as a deterrent to tunneling and may soon be recommended as a control alternative. c. There are no biological control tactics currently available to control termites. d. Least-toxic chemical control tactics will involve the use of insect growth regulators (used as baits) and/or chemical barriers that are undetectable by termites. 1PM PLAN for Doc Bk 03014643 OPR Vol 2218 p 12 TERMITES (6/26/00) Active Ingredient Protection Method Product Name Fenvalerate Chemical bather PydrinTM Imidacloprid Chemical barrier Premise(s) Hexaflumuron Insect growth regulator 4. This 1PM plan is a dynamic document. If other control tactics are found effective, then tkis plan will be amended to include those tactics. No regularly scheduled pesticide applications are planned. Doc Bk 03014643 CPR Vol 2218 1PM PLAN for RODENTS (6/26/00) 1. Pest(s) to be controlled: rodents. 2. Biology of the common house mouse, Mus musculus, roof rat, norvegicus: rattus and Norway rat, Rattus are found The house mouse, roof and Norway rats are rodents intimately associated with people, almost everywhere humans live or work. While wild mice and ratc will invade houses when weather changes, these pests are dependent on man for shelter and food. The reproductive rate of rodents in general and mice in particular is very high. Female mice produce 10 litters a year, 6-7 young per litter. Rats are almost as productive, but suffer high mortality. All rodents respond to trapping or other declines in their population by producing more litters. Strategies to control rodents involve primarily preventative steps to limit access to shelter and food, trapping to reduce small populations, and poisoning. 3. Control tactics: a. Physical control tactics will include the filling of access holes, making food storage rodent-proof, and the use of barriers. These measures will include the inspection of sewer lines into dwellings and cracks in foundations. b. Mechanical control tactics will include the trapping of rodent populations in snap traps or glue boards. A large number of traps will be placed to have the desired effect on the population. c. The use of domestic cats will be considered as a biological control tactic, if they will not become pests themselves. d. Non-toxic and less persistent control tactics will include the use of cholecalciferol, which will not lead to secondary poisoning. e. Active Ingredient(s) Product Name Cholecalciferol Quintox® More persistent chemical control tactics will include the use of anticoagulants placed in bait boxes to prevent secondary poisoning. Active Ingredient(s) Product Name Warfarin and Sulfaquinoxaline Prolin® 4. This 1PM plan is a dynamic document. If other control tactics are• found effective, then this plan will be amended to include those tactics. No regularly scheduled pesticide applications are planned. P Bk 1PM PLAN for 03014643 (IPR Vol 2218 ROACHES (6126/00) 1. Pest(s) to be controlled: cockroaches 2. Biology of the German cockroach, Blattella germanica: There are five speèies of cockroaches that commonly infest houses, with the Gennan cockroach being one of the most widely distributed. Roaches are tropical insects that have adapted to living with man by seeking areas where they can get warmth and moisture, such as bathrooms and kitchens. Female roaches glue egg cases, called ootheca, to the surfaces of any dark place. The average development time for the German cockroach from egg to adult is 55-68 days. Adults can live more than 200 days. They are active at night. 3. Control tactics: a. Physical control tactics will include the sealing of cracks and crevices and the screening of windows and vents to limit access from the outside. Roach traps will be used to monitor to pest population. b. Cultural control tactics will include good sanitation, including the proper storage of food and regular cleaning. c. There are currently no biological control tactics available for control of cockroaches. d. Non-toxic and less persistent control tactics will insecticidal dusts and baits, and insect growth regulators. Active Ingredient(s) 4. Product Name Boric acid powder Roach Rid® Silica aerogel and Pyrethrum Drione® Hydramethylnon Combat® Hydroprene Gencorlu This 1PM plan is a dynamic document. If other control tactics are found to be effective, then this plan will be amended to include those tactics. No regularly scheduled pesticide applications are planned. p 12 Doc 1PM PLAN for Bk OPR Vol p218 MOSQUITOES (6/26/00) 1. Pest(s) to be controlled: mosquitoes 2. Biology of the mosquito, Order Diptera. Family Culicidae: Adult mosquitoes are small, slender, long-legged flies with a long piercing mouthpart called the proboscis. Mosquitoes develop through four distinct stages: egg, larva, pupa, and adult. Adult females feed on animal blood for the protein needed to produce eggs. Eggs are laid sing!y or in on still or slow-moving water. Some mosquitoes lay eggs in temporary water basins such as tree holes or at the edges of flood prone areas. Mosquito eggs may lie donnant for months before hatching, but under most circumstances hatch Within 2 to 6 days. The aquatic larva and pupa stages each take from 4 to 10 days to develop and represent the most vulnerable stages. Adults can live up to 2 months after emergence. Most mosquitoes die within yards of where they emerged. The most effective method of controlling mosquitoes is to limit the number of water basins where eggs can hatch. Examples of temporary basins include cans and jars, clogged roof gutters, used tires, plant saucers, plastic sheeting, and wheelbarrows. Larger, more permanent water basins can be drained or filled in. However, not all water basins can or should be altered for environmental reasons. In addition, the excessive use of fertilizers should be discouraged as fertilizers in water Will promote. algae blooms that protects the mosquitoes from predation by fish. 3. Control tactics: a. Physical control tactics will include the use of screens on windows and doors. Electric "bug zapper? will not be used, as they are not effective at reducing mosquito populations since they target only adults, and affect non-target insect populations as well. b. Mechanical control tactics Will include the use of suffocating surface film where practical. This will include those basins not subject to runoff. The films to be used are highly refmed and biodegradable, with no effect on human or non-target species. 4. c. Biological control tactics Will include the use of native mosquito-eating fish (Gambusia) in permanent pools, where a viable fish population can be maintained. d. Least toxic and less persistent chemical control tactics will include the use of Bacillus thuringiensis israelensis or pyrethrum larvicides. These products will be applied to water basins where mosquito larvae develop. Active Ingredient(s) Product Name Bacillus thuringiensis israelensis Mosquito Dunks® Encapsulated pyrethrum Tossits® This 1PM plan is a dynamic document. If other control tactics are found effective, then this plan will be amended to include those tactics. No regularly scheduled pesticide applications are planned. P Doc Bk Vol 03014643 OPR 2218 p 13? 1PM PLAN for FLEAS (6/26/00) 1. Pest(s) to be controlled: fleas. 2. Biology of the cat flea, Ctenocephalides felis: egg, larva, Fleas are associated with warm-blooded animals and pass through four life pupa, and adult. Optimal flea development is at 65 to 80 degrees F. with a relative humidity of 70%. Hot dry summers reduce flea populations while cool rainy weather increases populations. When adult fleas emerge from pupae, they immediately seek a blood meal from warm-blooded animals. After mating, females lay eggs on hosts or on their sleeping areas. Eggs hatch into larvae within 12 days and usually feed on organic debris for 8-24 days. Pupae usually emerge into adults in 5-7 days. If conditions for development are unfavorable, larvae can live for up to 200 days and pupae for up to one year. An effective control strategy is to arrest flea development before the pupal stage to prevent explosive population growth when optimal conditions occur. 3. Control tactics: a. Physical control tactics will include combing and bathing of pets, and vacuuming or washing of rugs, carpets, furniture and pet sleeping areas. The number of fleas captured in combs is to be used as an indicator of the overall flea population and should be monitored. When fleas reach annoying levels, an increase in fleas captured in combs prompts the next control tactic. b. Mechanical control tactics will include the screening of pets from areas where fleas congregate or where vacuuming or washing would be difficult. If flea monitoring indicates mechanical controls have not decreased the flea population, then next control tactic is prompted. Note: Some non-toxic control products work mechanically, but are included in the non-toxic category. c. Biological control tactics include the use of nematodes, which are slender, microscopic, unsegmented worms. This nematode has been cultured to hunt, seek, and destroy specific soil-borne insects. Active Ingredient Neopleotana Carpocapsae (nematode) Product Name I ANTidoteTM d. Non-toxic and less persistent control tactics will include dusting pets, and the places they inhabit, with products containing pyrethrum, silica aerogel, or diatomaceous earth. Yards or other outdoor areas inhabited by pets will be sprayed with products containing insecticidal soap, pyrethrum, or rotenone. Higher concentrations of fleas may occur in the shady areas versus the dry sunny areas. An insect growth regulator will be added to the spray before application. Doe Bk 03014643 OPR Vol 2218 1PM PLAN for F1JEAS (6/26/00) e. Active Ingredient(s) Product Name Silica aerogel, pyrethrins, and piperonyl butoxide Drione® Pyrethrins, piperonyl butoxide, and diatomaceous earth Permagard® Insecticidal soap Safer's Soap® Pyrethrins, piperonyl butoxide, and rotenone Organocide® Fenoxycarb Torus® More persistent chemical control tactics will includeusing pet collars containing organophosphates, and the use of pyrethroids to control fleas outside. Active Ingredient Product Name Dichorovos Hartz® Permethrin Flee® 4. This 1PM plan is a dynamic document. If other control tactics are found effective, then this plan will be amended to include those tactics. No regularly scheduled pesticide applications are planned. 132 Doe 1PM PLAN for FIRE ANTS Bk 43 OPR Vol 2218 P 13 (6/26/00) I. Pest to be controlled: red imported fire ants 2. Biology of the red imported fire ant, Solenopsis invicta: The red imported fire ant is a tropical insect that was accidentally introduced into the United States in the 1930s and has spread unchecked across the Southeast and into Texas: Fire ants mating flights that usually occur in the spring and fall, but may disperse naturally occur anytime warm humid conditions exist, even during the winter. Fire ant queens are also dispersed by the movement of infested nursery stock and turf sod, and even by vehicles. Fire ant colonies are known to raft to higher ground during floods. The most visible indication of the presence of fire ants is their characteristic cone-shaped mounds. The only way to effectively control or suppress fire ants is to use a method that will stop egg production by the queen(s). Killing workers will have no lasting effect on the fire ant colony. Therefore the use of granular insecticides, which frequently do not come in cohtact with the queen, is not a long-term solution. The ineffective use of pesticides, especially in environmentally sensitive areas, should be avoided. 3. Control tactics: a. Physical control tactics will include the use of hot water to drench individual fire ant mounds. Mounds will be drenched mid-morning with at least a gallon of hot water on the sun-side of the mound in an attempt to kill queen(s). Drenched mounds will be rebuilt by surviving workers, but the colony will soon disperse if the queen is killed. If mounds persist, it will prompt the use of the next control tactic. b. There are no mechanical control tactics available to control fire ants. c. Biological control tactics include the use of nematodes, which are slender, microscopic, unsegmented worms. This nematode has been cultured to hunt, seek, and destroy soilboring fire ants by invading ant colonies. Product Name Active Ingredient I ANTidote Neopleotana Carpocapsae (nematode) I d. Non-toxic and less persistent control tactics include the broadcast of fire ant baits. Fire ant baits are designed to be attractive to foraging fire ants and eventually become passed to the queen(s). The effect of the bait will be to neutralize the queen by stopping egg production. Because fire ants will not forage when ground temperature is below 700 or above 95°, and because the baits will not remain attractive if wet, care shall be taken to apply the baits when the soil and vegetation are warm and dry. Apply baits when no rain is expected for at least 8 hours. In summer, apply baits in the evening, since ants do not forage during extreme heat. As fire ant baits require several weeks or more to affect Bk 1PM PLAN for 03014643 OPR Vol 2218 FIRE ANTS (6126/00) colonies, the next control tactic will only be prompted by the persistence of active mounds over a long period. Active Fenoxycarb e. Product Name S Logic® Hydramethylnon Amdro®, Combat® Spmosad Eliminator® Methoprene Extinguishtm Abamectin AscendTM, Raid® Pyriproxyfen Spectracide® More persistent chemical control tactics will include the use of liquid drenches or dusts that kill ants on contact. These products are appropriate for individual mound treatments only. Active Ingredient Product Name d-limonene Pyrethins, silicon dioxide, and piperonyl butoxide Organic SolutionsTM 4. This 1PM plan is a dynamic document. If other control tactics are found effective, then this plan will be amended to include those tactics. No regularly scheduled pesticide applications are planned. p Doc Bk OPR Schedule 7 Water and Energy Conservation Recommendations Vol 2218 P Doc Bk OPR Vol 2218 P Water Conservation — Tips Tips for saving water You can make a difference Water conservation and effidency are important to the protection of our drinkingwater resources. By using water wisely, you can lessen aemand on the water supply AND save money on your water bill. Here are some tips for saving water outdoors, when watering, mowing and planting; and indoors in the bathroom, kitchen and around the house. OUTDOORS Watering In the summer, lawn watering and other outdoor uses can account for 50 to 80 percent of home water use. Studies show that as much as half of this outdoor use is wasteful. • • • • • • • • Don't overwater your landscape. It can cause yellowing leaves or poor plant health. Give plants only the amount of water that they need. Use low-angle sprinklers that produce droplets of water. Sprinklers that spray the water high into the air or produce a mist or fine spray lose much of the water through evaporation. Don't water on windy days. Set sprinklers to water the lawn, not sidewalks and driveways. Use drip irrigation for shrub beds, gardens and trees. Drip irrigation systems apply water directly to the root, where it does the most good, and reduces water loss from evaporation. Adjust your watering habits or irrigation system according to the weather and season. Check your sprinkler or irrigation systems regularly for any leaks, and fix them. Be sure your hose has an automatic shutoff nozzle to ensure water is not wasted when the hose is left unattended. Mowing • • • Don't cut the grass too short. Longer blades of grass will reduce evaporation and root stress because shaded soil does not dry out as quickly. Mow regularly with a sharp blade so that only 1/2 to 314 of an inch is cut off each time. This practice will prevent the grass from turning yellow. Leave grass clippings on the lawn. Grass clippings contain valuable nutrients for the soil and plants. If left on the lawn, the clippings will reduce the need for additional, expensive fertilizers. Dcc • Bk 03014643 OPR Vol 2218 P 139 Water Conservation — Tips Planting Use mulches in plower and shrub beds. Mulches cover and shade soil, minimize evaporation, reduce weed growth, and slow erosion. Mulches also add a decorative appearance to the landscape. Add two to four inches of organic material, such as peat or compost, to the soil. Greater • • soil depth will increase the ablifty of the soil to retain moisture. Use water-wise plants. Native and adaptive plants will use less water and be resistant to local plant diseases and pests. Recognize that different plants require different amounts of water. Place your plants according to their water needs. Place plants that need occasional watering in one zone and those that only need natural rainfall in another zone. This way, you will not waste water on plants that don't need it. • • IN DOORS Bathroom Bathroom use accounts for about 75 percent of the water used inside the home. • • • • • • • Check regularly for any leaks and fix them. Most common bathroom leaks are found in toilets, faucets, and water hose bibs. Replace older, larger-use toilets with the newer ultra-low flush models. Standard toilets manufactured prior to the 1980$ usually require five to seven gallons per flush. Toilets sold during the 80s and early 90s use 3.5 gallons per flush. Since 1992, new toilets must use 1.6 gallons or less per flush. Install a displacement device, such as a plastic bottle or toilet tank bag or "bank," inside the toilet tank. These devices can save up to 20 percent of the water your toilet uses. (Note: Do NOT use a brick — it can crumble and damage the fixture.) Do NOT use the toilet to dispose of paper, facial tissues, or cigarettes. Take a five-minute shower, rather than a bath. Install a low-flow showerhead. It can save about half the amount of water you typically use in the shower, while still providing a refreshing, cleansing shower. Turn the tap water off while brushing your teeth or shaving. Doe Bk OPR Vi 22?8 Water Conservation — Tips About 8 percent of in-home water use takes place in the kitchen. • • • • • • • • • Install a low-flow faucet aerator, which can cut water use in half. Soak pots and pans before washing. Fill the basin or a pan with water to wash fruits and vegetables. Instead of letting hot water run over frozen foods, let them thaw in the. refrigerator, or thaw them in a small amount of boiling water or in the microwave. Keep a pitcher of water in the refrigerator rather than running tap water until it Is cool enough to drink. Avoid using the garbage disposal. Instead, compost your food wastes. You can use the compost in your garden to improve your soil, as well as reduce your water use and the need for expensive fertilizers. When buying a new dishwasher, consider purchasing a water-saving model. Newer models can cut water use by 25 percent and are no more expensive than non-conserving models. Wash only full loads in the dishwasher. Around the house • • • • When buying a new clothes washer, consider purchasing a water-saving model. New horizontal axis models can save up to 40 percent of the water used a conventional model. Wash only full loads in the clothes washer. Insulate hot water pipes where possible to avoid long delays (and wasted water) while waiting for the water to "run hot." Be sure the water heater thermostat is not set too high. Very hot sethngs (higher than 125 degrees F) waste energy since the water has to be mixed with cold water before use. Contact Us For more information on LCRA's water conservation programs or publications, please call (512) 473-3200, Ext. 2230 or, toll-free, 1-800-776-5272, Ext. 2230, or e-mail Water Conservation Doc Bk OPR Ene, Vol 2218 P 13 :ion Tips overhangs, and the use of interior shading devices are encouraged in order to reduce utility demands. • Recessed windows, solar • Consider planting vegetation along south and west facades to limit solar exposure and reduce cooling costs. • Water heaters — use gas or heat pump fixtures with COPs of 2.5 — 3. • Insulation — walls should be R-19 ceilings should be minimum of R-26 in sloped ceilings and R-34 in flat ceilings. • Heating/cooling system efficiency ratio (SEER) should be 12+. • Solar screens or Low E squared glass — placed on south and/or west facing facades. • Showers — Install ultra-low flow shower heads with a maximum flow rate of 2.5 GPM. • Toilets — install ultra-low flush fixtures which use 1.5 — 3.5 gallons per flush. • Install water efficient dishwashers. EXHIBIT '_' Dcc 014643 Schedule 8 Street Trees and Approved Trees and Landscaping Materials OPR 8 Pa Dot, 03014643 PLANT LIST March 18 ,2003 SYM COMMON NAME BOTANICAL NAME Afghan Pine Bald Cypress Burr Oak Cedar Elm Chinese Pistache Deodara Cedar Live Oak Shumard Oak Texas Ash Pinus eldarica Taxodlum distlchum Quercus macrocarpa Ulmus ciassifolia Pastada chinensis Cednjs deodara Quercus virginiana Quercus shumardli Fraxinus texensis TREES ORNAMENTAL TREES Bradford flowering pear Crape Myrtle 'Bashams Party Crape Myrtle 'Catawba' Crape Myrtle 'Natchez' Desert Willow Flameleaf Sumac Golden Rain Tree Mexican Buckeye Mexican Plum Possomhaw Holly (Female) Red Bud Texas Mountain Laurel Texas Persimmon Vitex, Chaste Tree Vaupon Holly Pyrus calleryana 'Bradford' Lagerstroemia indlca light pink Lagerstroemia indica bright purple Lagerstroemia indlca white flowered Chilopsis ilnearis Rhus lanceolata Koelreute,ia bipinnata Ungnadia speciosa Pninus mexicana hex decidua Cercis canadensis Sophara secundiflora Diospyros texana Vitex Agnus - castus hex vomitoria 'Pride of Houston' SHRUBS Agarita American Beautyberry Autumn Sage - Burgundy Autumn Sage - Coral Autumn Sage -White Bird of Paradise Shrub Burford Holly Butterfly Bush Cotoneaster Damianita Dwarf Burford Holly Dwarf Chinese Holly Dwarf Vaupon Holly Eleagnus Flame acanthus Indian Hawthorn Mexican Bush Sage Nandina (Variety) Oleander, Hardy Red Oleander, Hardy Pink Mexican Oregano Pavonia Pink Abelia Primrose Jasmine Pomegranate, dwarf Berbei-is 1,ifolioata Cahhicarpa americana Salvia greggii Salvia greggil Salvia Caesaipinia gilliesli hex comuta 'Bufordil' Buddleia altemifolia Cot oneaster glaucophyllus Chrysactinia mexlcana hex comuta 'Bufordil Nana' hex comuta 'Nana' ilex vomitoria 'Nana' E!aeagnus x Ebbingei Anisacanthus quad,ifidus var. wiightii Paphiolepis indica 'Springtime' Salvia leucantha Nandina Stream' Nenum oleander 'Hardy Red' Nerium oleander 'Hardy Pink' Poliomintha longiflora Pavonia lasiopetala Abelia grandifiora 'Edward Goucher' Jasminum mesnyi Punica granatum 'Nana' Bk OPR Vol 2218 P Doc oftkThails Rosemary Rose of Sharon, Bluebird Rose of Sharon, Diana Rose of Sharon, Red Heart RedYucca Sotol, Texas Blue Texas sage Yucca, Blue Soft-Leaved Yucca Yucca, Thompson's Iilblscus Sydacus Hibiscus syriacus Diana' Hibiscus synacus 'Red Heart' Hesperaloepan4iloia Dasyr,rlon texaAuin • • Leucoph$'lIum ht,tescens 'Siwerado' Yucca recwvifolla Yucca pendula Yucca nipicola . VINES AND GROUNDCOVERS Artemesla Carolina Yellow Jessamine Coral Honeysuckle Cross Vine Gregg Dalea Fig Lantana, Irene Lantana, Dallas Red Lady Banks Rose Ililope, Giant Liriope, 'Big Blue' Lirlope, 'Silver Sunprool' Monkey Grass Queen's Wreath New Gold Trailing Lantana Purple Trailing Lantana White Trailing Lantana Tmmpet Vine 'Madame Galen' GRASSES AND PERENNIALS Sacahuista, Bear Grass Copper Canyon Daisy Gulf Coast Muhly indigo Spires Salvia Lindheimer Muhly Japanese Maiden Grass Periwinkle, Bigleaf Purple Fountain Grass Purpleleaf Honeysuckle Zebra Grass Zexmenia, orange SOD Bermuda Grass SEEDED LAWN Bermuda Grass NATIVE GRASS / WILDFLOWER MIX Blue Grama Treated 'Top Gun' Buffalo Grass Texas Bluebonnets Prairie Verbena Aitemesia ?owis Castle' Gelsemlum sempervirens Lonicera se,peivirens Bignonia capreolata Dalea gregg! Ficus pumila Lantana camera 'Irene' Lantana camera Dallas Red' Rosa banksaea Liriope gigantea Lidope muscari 'Big Blue' Lidope muscail 'Silver Sunproof Ophiopogonjaponicus Antlgonon leptopus Lantana montevidensis 'New Gold' Lantana monfevidensis 'Purple Trailing' Lantana montevldensis White Trailing' Campsis radicans 'Madame Galen' Nolina erumpens Tagetes lemmonil Muhienbergia capillaris Salvia longispicata x farinacea Muhienbergia lindhelmorii Miscarithus Japonicus 'gracillimus' Vinca major Pennisetum afropurpureum Lonicera japonica atropurpurea Miscanthus japonicus zebrinus Zexmenia hispida Bk DPR Vol P Bk 03014643 OPR • Greenthread Creepsis • • • • .. ..• IlL IFFICIL ftftIC IEORDS Lie: Nay Perennial Rye Grass . Annuals vatIely Douseni Mzaber: Lee Carlisle County Clerk By Lynn Deputy nays County at 03014543