concealed type lavatory carrier

Transcription

concealed type lavatory carrier
 Fixture Carriers
CONCEALED TYPE LAVATORY CARRIER
1. Tandem keepers in slots on the arm permit positioning of leveling
screws on the job to suit punchings of any lavatory specified.
2. Screws in keepers can then easily be moved up or down to level
the lavatory.
3. The securing lock device is positioned on the arm and tightens
against the fixture to hold it rigidly in place.
4. The sleeve can be adjusted to suit various wall thicknesses.
5. The final setting of the arm out from the wall can be made
from the face of the finished wall after the wall is built.
6. The set screws are easily accessible for quicker adjustment.
7. Arm with the locking device, tandem keepers, and adjustable
sleeve, is completely assembled at the factory.
8. Hardware is plated to prevent corrosion.
Detail of securing method
for concealed arm carrier.
Detail of leveling arrangement
for concealed arm carrier.
Detail of parts of concealed arm
carrier in or behind finished wall.
45
Detail of parts of concealed arm carrier.
For roughing dimensions for specific fixtures, please
refer to the Josam website, www.josam.com.
46
Parts & Details Lavatory, Sink & Urinal Carriers
The drawings on this page show the relationship between mating parts of carriers covered in this section.
Fixture Carriers
(-66) OPTION, SPLIT HEADER FOR STAINLESS STEEL ARMS
In many cases arms are supplied by the manufacturers of stainless steel fixtures. The mounting
hole spacing in the back of the arm (Y Dim.) varies widely by sink and manufacturer. The -66 split
header is adjustable to allow for the mounting of this type of sink and arm combination.
(-75) OPTION, 2” ESCUTCHEONS
(-76) OPTION, 4” ESCUTCHEONS
Escutcheons provide manufacturers’ specified distance from wall to back of a slab type
lavatory to prevent water from deteriorating finished wall when concealed arms are
used. Furnished in polished chrome.
(-77) OPTION, 6” ESCUTCHEONS also available.
Fixture Carriers
47
48
FIXTURE CARRIER
SPECIFICATION:
JOSAM 17000 SERIES RE-USABLE ALIGNMENT TOOL FOR FLOOR
MOUNTED FIXTURE CARRIERS WITH UPRIGHTS.
REUSABLE ALIGNMENT TOOL
SERIES
17000
LAVATORY CARRIER
SPECIFICATION:
JOSAM 17100 SERIES FLOOR-MOUNTED, SINGLE
LAVATORY CARRIER WITH CONCEALED ARMS, LEVELING
AND SECURING SCREWS, STRUCTURAL UPRIGHTS, AND
WELDED FEET.
FLOOR-MOUNT
CONCEALED ARM
SERIES
: VARIABLE DIMENSION.
DEPENDS ON FIXTURE.
REUSABLE ALIGNMENT TOOL
AVAILABLE.
17100
-BB
BACK-TO-BACK CARRIER (SEPARATE
SUBMITTAL FOR THIS OPTION AVAILABLE)
-10
EXTENSION SLEEVES LONGER THAN
STANDARD (SPECIFY WALL THICKNESS)
-60 VALVE PLATE FOR ATTACHING TO UPRIGHT
C"
29"
8"
-67
CONCEALED ARM CARRIER FOR
WHEELCHAIR LAVATORY
-75
2" CHROME PLATED ESCUTCHEONS
-76
4" CHROME PLATED ESCUTCHEONS
-77
6" CHROME PLATED ESCUTCHEONS
3 3/8"
2"
STANDARD ADJUSTABLE
SLEEVE 6-1/2"
-75 OPTION SHOWN:
2" ESCUTCHEON
3 1/8"
1/2" MIN
4" MAX
ALIGNMENT TOOL
POSITIONED FOR UPRIGHT
SPACING AT TIE ROD
ESCUTCHEON
FINISHED WALL
F"
2"
C"
MANUFACTURER
_______________
NUMBER
_______________
SIZE
_______________
1 1/2"
NAME
_______________
FINISHED WALL
A"
DIMENSIONS
A _____________
Fixture Carriers
ALIGNMENT TOOL
POSITIONED FOR UPRIGHT
SPACING AT FLOOR
3"
EXAMPLE VIEW
04/21/08
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
F _____________
RIM HEIGHT________
*CARRIER NOT INCLUDED
DATE OF LAST CHANGE:
C _____________
FINISHED FLOOR
NOTES
DATE OF LAST CHANGE:
4 1/2"
JOSAM RECOMMENDS THAT ALL FEET
BE SECURED TO FLOOR WITH 1/2"
BOLTS AND ANCHORS BY OTHERS
06/18/08
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
BASED ON "A" DIM SHOWN
REFERENCE DRAWING A-08201-K
NOTES
Fixture Carriers
SPECIFICATION:
JOSAM 17100-BB SERIES FLOOR-MOUNTED,
BACK-TO-BACK LAVATORY CARRIER WITH CONCEALED
ARMS, LEVELING AND SECURING SCREWS, STRUCTURAL
UPRIGHTS AND WELDED FEET.
LAVATORY CARRIER
FLOOR-MOUNT
CONCEALED ARM
SPECIFICATION:
JOSAM 17120 SERIES WALL-MOUNTED, SINGLE LAVATORY
CARRIER WITH CONCEALED ARMS, LEVELING AND
SECURING SCREWS, AND ADJUSTABLE WALL PLATE.
17100-BB
SERIES
SIZE
_______________
C"
WALL-MOUNT
CONCEALED ARM
17120
SERIES
MANUFACTURER
_______________
NUMBER
_______________
LAVATORY CARRIER
2"
2 3/4"
1 1/2"
F
C
(13" MIN-22.5" MAX)
5"
NAME
_______________
DIMENSIONS
FINISHED
WALL
A _____________
2"
C _____________
F _____________
F"
F"
5" MIN
12" MAX
1 1/2"
1 1/2"
RIM HEIGHT __________
1 1/2"
BASED ON "A" DIM SHOWN
X -BB
A
BACK TO BACK CARRIER
-10
EXTENSION SLEEVES
LONGER THAN STANDARD
(SPECIFY WALL THICKNESS)
-60
VALVE PLATE FOR
ATTACHING TO UPRIGHT
FINISHED WALL
FINISHED FLOOR
DENOTES VARIABLE. DIMENSION
DEPENDS ON FIXTURE. STANDARD
ADJUSTABLE SLEEVE IS 4" LONG
CONCEALED ARM CARRIER
-67 FOR WHEEL CHAIR LAVATORY
3 1/2"
FINISHED
WALL
FINISHED
WALL
2" CHROME PLATED
ESCUTCHEONS
-76
4" CHROME PLATED
ESCUTCHEONS
-77
6" CHROME PLATED
ESCUTCHEONS
2"
A"
: VARIABLE DIMENSION.
DEPENDS ON FIXTURE.
REUSABLE ALIGNMENT TOOL
AVAILABLE.
FINISHED
FLOOR
49
DATE OF LAST CHANGE:
06/18/08
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
-BP*
-MMB*
WITH BACK PLATES
WITH MOVABLE MOUNTING BRACKETS
-10*
EXTENSION SLEEVES LONGER THAN
STANDARD (SPECIFY WALL THICKNESS)
-75
-76
-77
2" CHROME PLATED ESCUTCHEONS
4" CHROME PLATED ESCUTCHEONS
6" CHROME PLATED ESCUTCHEONS
NOTES
NUMBER
_______________
SIZE
_______________
NAME
_______________
DIMENSIONS
A _____________
* SEPARATE SUBMITTAL FOR THIS OPTION AVAILABLE
RIM HEIGHT ________
BASED ON "A" DIM SHOWN
REFERENCE
DRAWING
A-08202-K
DATE OF LAST CHANGE:
C _____________
F _____________
-75 OPTION
CHROME PLATED
ESCUTCHEON
JOSAM RECOMMENDS THAT ALL FEET BE SECURED
TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS
MICHIGAN CITY, INDIANA
5"
STANDARD ADJUSTABLE
SLEEVE 6-1/2"
-75 OPTION SHOWN:
2" ESCUTCHEON
3"
MANUFACTURER
_______________
2"
2 3/4"
ESCUTCHEON
FINISHED
WALL
-75
02/21/14
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.


NOTES
50
LAVATORY CARRIER
SPECIFICATION:
WALL-MOUNT
CONCEALED ARM
JOSAM 17120-10 SERIES WALL-MOUNTED, SINGLE
LAVATORY CARRIER WITH CONCEALED ARMS, LEVELING
AND SECURING SCREWS, AND ADJUSTABLE WALL PLATE.
SERIES
17120-10
LAVATORY CARRIER
SPECIFICATION:
WALL-MOUNT
CONCEALED ARM
JOSAM 17120-BP SERIES WALL-MOUNTED, SINGLE LAVATORY
CARRIER WITH CONCEALED ARMS, LEVELING AND SECURING
SCREWS, ADJUSTABLE WALL PLATE AND BACK PLATE.
SERIES
17120-BP
6" MAX
F
1" MIN
1 1/2"
6" MAX
C
1 1/2"
F
5"
C
5"
FINISHED
WALL
1 1/2"
1 1/2"
FINISHED WALL
A
A
FINISHED WALL
FINISHED FLOOR
FINISHED FLOOR
DENOTES VARIABLE DIMENSION
DEPENDS ON FIXTURE.
STANDARD ADJUSTABLE SLEEVE IS 8-1/2" LONG
FINISHED WALL
1" MIN
MANUFACTURER
_______________
2"
F
MANUFACTURER
_______________
2"
NUMBER
_______________
6" MAX
NUMBER
_______________
SIZE
_______________
NAME
_______________
Fixture Carriers
5"
DIMENSIONS
X
-75 OPTION
CHROME PLATED
ESCUTCHEON
DATE OF LAST CHANGE:
-BP
WITH BACK PLATES
A _____________
-10
EXTENSION SLEEVES LONGER THAN
STANDARD (SPECIFY WALL THICKNESS)
C _____________
-75
-76
-77
06/18/08
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
2" CHROME PLATED ESCUTCHEONS
4" CHROME PLATED ESCUTCHEONS
6" CHROME PLATED ESCUTCHEONS
JOSAM COMPANY
MICHIGAN CITY, INDIANA
X -BP
-10
F _____________
-75
-76
-77
RIM HEIGHT ________
BASED ON DIM. "A" SHOWN
NOTES
DENOTES VARIABLE DIMENSION
DEPENDS ON FIXTURE.
STANDARD ADJUSTABLE SLEEVE 8-1/2"
-75 OPTION
CHROME PLATED
ESCUTCHEON
DATE OF LAST CHANGE:
SIZE
_______________
NAME
_______________
DIMENSIONS
WITH BACK PLATES
EXTENSION SLEEVES LONGER THAN STANDARD
(SPECIFY WALL THICKNESS)
2" CHROME PLATED ESCUTCHEONS
4" CHROME PLATED ESCUTCHEONS
6" CHROME PLATED ESCUTCHEONS
06/18/08
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
A _____________
C _____________
F _____________
RIM HEIGHT_________
BASED ON "A" DIM. SHOWN
NOTES
Fixture Carriers
LAVATORY CARRIER
SPECIFICATION:
JOSAM 17120-MMB SERIES WALL-MOUNTED, SINGLE LAVATORY
CARRIER WITH CONCEALED ARMS, LEVELING AND SECURING
SCREWS, AND MOVABLE MOUNTING BRACKETS FOR SECURING TO
WALL PLATE BY OTHERS.
WALL-MOUNT
CONCEALED ARM
17120-203-H
SERIES
REF. NO.: M1456
PLATE FURNISHED
BY OTHERS
11/16"
1 1/2"
1 1/4"
F
WALL-MOUNT
CONCEALED ARM
JOSAM 17120 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER
WITH CONCEALED ARMS, LEVELING AND SECURING SCREWS, AND
ADJUSTABLE WALL PLATE
17120-MMB
SERIES
1 1/4" MIN
2 1/2" MAX
LAVATORY CARRIER
SPECIFICATION:
2"
1 1/4"
1 1/2"
ADJUSTABLE
16 5/8"
C
2"
5"
1 1/2"
14 1/2"
MAX.
C
5"
1 1/2"
A
FINISHED WALL
FINISHED FLOOR
FINISHED WALL
7/8"
(4) SECURING HOLES
FOR 1/2" BOLTS
FINISHED WALL
MANUFACTURER
_______________
F
NUMBER
_______________
3 3/4"
SIZE
_______________
DENOTES VARIABL DIMENSION
DEPENDS ON FIXTURE
STANDARD ADJUSTABLE SLEEVE IS 6 1/2"
2"
-75 OPTION
CHROME PLATED
ESCUTCHEON
51
DATE OF LAST CHANGE:
X -MMB
06/18/08
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
WITH MOVABLE MOUNTING BRACKETS
-10
EXTENSION SLEEVES LONGER THAN
STANDARD (SPECIFY WALL THICKNESS)
-75
-76
-77
2" CHROME PLATED ESCUTCHEONS
4" CHROME PLATED ESCUTCHEONS
6" CHROME PLATED ESCUTCHEONS
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NAME
_______________
DIMENSIONS
A _____________
C _____________
F _____________
RIM HEIGHT_________
BASED ON "A" DIM. SHOWN
NOTES
DATE OF LAST CHANGE:
06/03/08
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
52
SPECIFICATION:
JOSAM 17125 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER
WITH CONCEALED ARMS, LEVELING & SECURING SCREWS AND STEEL
PLATE FOR ATTACHING TO STUDS.
LAVATORY CARRIER
WALL-MOUNT CONCEALED ARM
SPECIFICATION:
JOSAM 17380 SERIES FLOOR-MOUNTED, SINGLE LAVATORY CARRIER
WITH EXPOSED ACID-RESISTING WHITE COATED ARMS, LEVELING AND
SECURING SCREWS, STRUCTURAL UPRIGHTS, WELDED FEET AND
CHROME PLATED TRIM.
17125
SERIES
LAVATORY CARRIER
FLOOR-MOUNT EXPOSED ARM
17380
SERIES
REUSABLE ALIGNMENT TOOL AVAILABLE
"X"
4 1/2"
FINISHED
WALL
C
FINISHED
WALL
C
2"
1/2" MIN
1 3/8" MAX
1 1/2"
1" MIN
4 1/2" MAX
2 1/2"
: VARIABLE DIMENSION.
DEPENDS ON FIXTURE.
STANDARD ADJUSTABLE
SLEEVE IS 4".
1 1/2"
MANUFACTURER
4"
"X"
12 1/2"
15 1/2"
12 1/2"
2"
: VARIABLE DIMENSION.
DEPENDS ON FIXTURE.
STANDARD ADJUSTABLE
SLEEVE IS 4".
F
MODEL
-201
-203
-507P
NUMBER
A
FINISHED
FLOOR
1/2" MIN
1 3/8" MAX
F
A
C
Fixture Carriers
F
4"
3 1/8"
NUMBER
NAME
DIMENSIONS
2"
MANUFACTURER
SIZE
FINISHED
WALL
FINISHED
FLOOR
EXTENSION SLEEVES LONGER THAN STANDARD (SPECIFY WALL THICKNESS)
2" CHROME PLATED ESCUTCHEONS
DATE OF LAST CHANGE:
4/23/15
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
C
-BB BACK-TO-BACK CARRIER
-10
-HD
HEAVY-DUTY
-60
VALVE PLATE FOR ATTACHING TO UPRIGHT
-VP
VANDAL-PROOF TRIM
-66
SPLIT HEADER FOR STAINLESS STEEL ARMS
DATE OF LAST CHANGE:
DIMENSIONS
A
3"
BASED ON "A" DIM SHOWN
-10
-75
SIZE
NAME
RECOMMEND
ALL FEET BE
SECURED TO
FLOOR WITH
1/2" BOLTS AND
ANCHORS BY
OTHERS.
RIM HEIGHT
CHROME PLATED ESCUTCHEONS (-75)
A
4/23/15
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
STUDS FOR WALLS OVER 4-1/2" (SPEC. WALL THICKNESS)
JOSAM COMPANY
MICHIGAN CITY, INDIANA
RIM HEIGHT
BASED ON "A" DIM SHOWN
NOTES
Fixture Carriers
SPECIFICATION:
JOSAM 17380-BB SERIES FLOOR-MOUNTED, BACK-TO-BACK
LAVATORY CARRIER WITH EXPOSED ACID-RESISTING WHITE COATED
ARMS, LEVELING AND SECURING SCREWS, STRUCTURAL UPRIGHTS,
WELDED FEET AND CHROME PLATED TRIM.
LAVATORY CARRIER
FLOOR-MOUNT EXPOSED ARM
17380-BB
SERIES
REUSABLE ALIGNMENT TOOL AVAILABLE
SINK CARRIER
SPECIFICATION:
JOSAM 17380-HD SERIES FLOOR-MOUNTED, SINGLE HEAVY-DUY SINK
CARRIER WITH EXPOSED ACID-RESISTING WHITE COATED ARMS,
LEVELING AND SECURING SCREWS, STRUCTURAL UPRIGHTS,
WELDED FEET AND CHROME PLATED TRIM.
FLOOR-MOUNT EXPOSED ARM
SERIES
REUSABLE ALIGNMENT TOOL AVAILABLE
"X"
- 201
- 203
MANUFACTURER
X = 16"
X = 20"
MANUFACTURER
_______________
_______________
NUMBER
C
_______________
SIZE
SIZE
NAME
_______________
2"
A ____________
NAME
1 MIN
4-1/2 MAX
_______________
5 MIN
12 MAX
NUMBER
FINISHED WALL
C
_______________
_______________
2"
_______________
1 1/2"
3 1/2"
A ____________
C ____________
C ____________
____________
F ____________
BASED
RIM HEIGHT
ON 'A' DIM SHOWN
RIM HEIGHT BASED
ON 'A' DIM SHOWN
1 1/2"
3 1/4"
3 1/2"
FINISHED
WALL
OFFSET ARMS FURNISHED
WHEN REQUIRED
FINISHED
WALL
A
FINISHED
FLOOR
FINISHED
WALL
F
VARIABLE DEPENDS ON
FIXTURE
53
DATE OF LAST CHANGE:
7/16/09
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
X -BB
BACK-TO-BACK CARRIER
-VP
VANDAL-PROOF TRIM
-10 STUDS FOR WALLS OVER 12" (SPECIFY WALL THICKNESS)
-60
VALVE PLATE FOR ATTACHING TO UPRIGHT
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
VARIABLE DEPENDS ON
FIXTURE
A
RECOMMEND ALL FEET
BE SECURED TO FLOOR
WITH 1/2" BOLTS AND
ANCHORS BY OTHERS.
FINISHED
FLOOR
3"
RECOMMEND ALL FEET
BE SECURED TO FLOOR
WITH 1/2" BOLTS AND
ANCHORS BY OTHERS.
17380-HD
3"
X
-HD
HEAVY-DUTY
-BB BACK-TO-BACK CARRIER
-VP
VANDAL-PROOF TRIM
DATE OF LAST CHANGE:
09/15/09
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
-10
STUDS FOR WALLS OVER 4-1/2" (SPEC. WALL THICKNESS)
-60
-66
VALVE PLATE FOR ATTACHING TO UPRIGHT
SPLIT HEADER FOR STAINLESS STEEL ARMS
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
54
SINK CARRIER
SPECIFICATION:
JOSAM 17380-BB-HD SERIES FLOOR-MOUNTED, BACK-TO-BACK
HEAVY-DUTY SINK CARRIER WITH EXPOSED ACID-RESISTING WHITE
COATED ARMS, LEVELING AND SECURING SCREWS, STRUCTURAL
UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM.
FLOOR-MOUNT EXPOSED ARM
SERIES
REUSABLE ALIGNMENT TOOL AVAILABLE
SPECIFICATION:
JOSAM 17390 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER
WITH EXPOSED ACID-RESISTING WHITE COATED ARMS, LEVELING
AND SECURING SCREWS, ADJUSTABLE WALL PLATE AND CHROME
PLATED TRIM.
17380-BB-HD
1 1/2"
MANUFACTURER
_______________
1 1/2"
SIZE
5"
FINISHED
WALL
_______________
NAME
6 MIN
13 MAX
FINISHED
WALL
_______________
1 1/2"
C
NUMBER
_______________
2"
17390
SERIES
4 1/2
C
LAVATORY CARRIER
WALL-MOUNT EXPOSED ARM
A
A ____________
C ____________
F ____________
4 1/2"
FINISHED
WALL
FINISHED
FLOOR
RIM HEIGHT 'F' BASED
ON 'A' DIM SHOWN
FINISHED
WALL
A
MANUFACTURER
_______________
VARIABLE DEPENDS ON
FIXTURE
NUMBER
_______________
3 1/4"
Fixture Carriers
FINISHED
FLOOR
RECOMMEND ALL FEET
BE SECURED TO FLOOR
WITH 1/2" BOLTS AND
ANCHORS BY OTHERS.
3"
X
X
-BB BACK-TO-BACK CARRIER
-HD HEAVY-DUTY
-VP VANDAL-PROOF TRIM
DATE OF LAST CHANGE:
8/17/09
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
OFFSET ARM FURNISHED
WHEN REQUIRED.
DENOTES VARIABLE DIMENSION
DEPENDS ON FIXTURE.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
NAME
_______________
DIMENSIONS
A _____________
C _____________
-BP WITH BACK PLATES*
-10 STUDS FOR WALLS OVER 13" (SPECIFY WALL THICKNESS)
-60 VALVE PLATE FOR ATTACHING TO UPRIGHT
-66
SPLIT HEADER FOR STAINLESS STEEL ARMS
SIZE
_______________
RIM HEIGHT_________
-VP VANDAL-PROOF TRIM
BASED ON "A" DIM. SHOWN
-10 STUDS FOR WALLS OVER 4-1/2" (SPEC. WALL THICKNESS)
* SEPERATE SUBMITTAL FOR THIS OPTION AVAILABLE
DATE OF LAST CHANGE:
2/23/10
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
Fixture Carriers
SPECIFICATION:
JOSAM 17390 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER
WITH EXPOSED ACID-RESISTING WHITE COATED ARMS, LEVELING
AND SECURING SCREWS, ADJUSTABLE WALL PLATE, BACK PLATES
AND CHROME PLATED TRIM.
LAVATORY CARRIER
WALL-MOUNT EXPOSED ARM
4 1/2"
1 1/4" MIN
JOSAM 17405 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER
WITH EXPOSED ACID-RESISTING WHITE COATED ARMS, LEVELING AND
SECURING SCREWS, MOUNTING RODS FOR SECURING TO WALL
PLATE BY OTHERS AND CHROME PLATED TRIM.
17390-BP
SERIES
1 1/2"
SPECIFICATION:
17405
SERIES
PLATE FURNISHED
BY OTHERS
1 1/2" MIN
1 7/8" MAX
C
LAVATORY CARRIER
WALL-MOUNT EXPOSED ARM
11/16"
1 1/4"
1 1/4"
1 1/2"
5"
C
1 1/2"
FINISHED WALL
A
FINISHED WALL
FINISHED WALL
FINISHED
WALL
A
FINISHED FLOOR
FINISHED FLOOR
MANUFACTURER
_______________
DENOTES VARIABLE DIMENSION
DEPENDS ON FIXTURE.
NUMBER
3 1/4"
_______________
NUMBER
_______________
SIZE
_______________
NAME
_______________
3 1/4"
X
-BP
-VP
-10
DIMENSIONS
NAME
_______________
DENOTES VARIABLE DIMENSION
DEPENDS ON FIXTURE.
DIMENSION BASED ON 1/4"
PLATE BY OTHERS.
C _____________
WITH BACK PLATES*
VANDAL-PROOF TRIM
STUDS FOR WALLS OVER 4-1/2" (SPEC. WALL THICKNESS)
SIZE
_______________
OFFSET ARM FURNISHED
WHEN REQUIRED.
A _____________
OFFSET ARM FURNISHED
WHEN REQUIRED.
MANUFACTURER
_______________
RIM HEIGHT_________
BASED ON "A" DIM. SHOWN
-VP VANDAL-PROOF TRIM
-10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS)
DIMENSIONS
A _____________
C _____________
RIM HEIGHT_________
BASED ON "A" DIM. SHOWN
*SEPARATE SUBMITTAL FOR THIS OPTION AVAILABLE
55
DATE OF LAST CHANGE:
3/04/10
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
DATE OF LAST CHANGE:
3/05/10
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
56
LAVATORY CARRIER
SPECIFICATION:
JOSAM 17550 SERIES FLOOR-MOUNTED, SINGLE LAVATORY CARRIER
WITH HANGER PLATE, ADJUSTABLE SUPPORTING RODS, STRUCTURAL
UPRIGHTS AND WELDED FEET.
FLOOR-MOUNT HANGER PLATE
SERIES
REUSABLE ALIGNMENT TOOL AVAILABLE
SPECIFICATION:
JOSAM 17550-BB SERIES FLOOR-MOUNTED, BACK-TO-BACK LAVATORY
CARRIER WITH HANGER PLATES, ADJUSTABLE SUPPORTING RODS,
STRUCTURAL UPRIGHTS AND WELDED FEET.
17550
SERIES
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
1 MIN
4 MAX
C
1 MIN
4 MAX
C
MANUFACTURER
_______________
HANGER
FURNISHED
WITH FIXTURE
FINISHED
WALL
17550-BB
2 1/2
2 1/2"
1 MIN
4 MAX
LAVATORY CARRIER
FLOOR-MOUNT HANGER PLATE
NUMBER
_______________
SIZE
_______________
B
FINISHED
WALL
FINISHED
WALL
NAME
_______________
B
HANGERS
FURNISHED
WITH
FIXTURE
DIMENSIONS
B _____________
3"
C _____________
BASED ON "A" DIM SHOWN
FINISHED
FLOOR
4 1/2
FINISHED FLOOR
RIM HEIGHT________
MANUFACTURER
_______________
3"
4 1/2"
RECOMMEND ALL FEET BE SECURED TO FLOOR
WITH 1/2" BOLTS AND ANCHORS BY OTHERS.
NUMBER
_______________
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
SIZE
_______________
Fixture Carriers
RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.
-BB
-CL
-UR
-WC
BACK-TO-BACK CARRIER*
CORNER LAVATORY CARRIER*
URINAL CARRIER*
WATER COOLER CARRIER*
-WCBL
WATER COOLER BI-LEVEL CARRIER*
-10
STUDS FOR WALLS OVER 4"
(SPECIFY WALL THICKNESS)
-60
VALVE PLATE FOR ATTACHING TO UPRIGHT
NAME
_______________
DIMENSIONS
X
-BB BACK-TO-BACK CARRIER
-10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS)
-60 VALVE PLATE FOR ATTACHING TO UPRIGHT
B _____________
C _____________
RIM HEIGHT________
BASED ON "B" DIM SHOWN
*SEPARATE SUBMITTAL FOR THIS OPTION AVAILABLE
DATE OF LAST CHANGE:
8/11/2009
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
DATE OF LAST CHANGE:
3/27/12
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
Fixture Carriers
URINAL CARRIER
SPECIFICATION:
JOSAM 17550-UR SERIES FLOOR-MOUNTED, SINGLE URINAL CARRIER
WITH HANGER PLATE, ADJUSTABLE SUPPORTING RODS, STRUCTURAL
UPRIGHTS AND WELDED FEET.
FLOOR-MOUNT HANGER PLATE
FINISHED
WALL
WATER COOLER CARRIER
FLOOR-MOUNT HANGER PLATE
17550-WC
SERIES
1" MIN
4" MAX
2 1/2"
C
1" MIN
4" MAX
PLATE PUNCHED
FOR USE WITH
BACK SUPPLY
FIXTURE
JOSAM 17550-WC SERIES FLOOR-MOUNTED, SINGLE WATER COOLER
CARRIER WITH HANGER PLATE, ADJUSTABLE SUPPORTING RODS,
STRUCTURAL UPRIGHTS AND WELDED FEET.
17550-UR
SERIES
REUSABLE ALIGNMENT TOOL AVAILABLE
2 1/2"
SPECIFICATION:
C
HANGER
FURNISHED
WITH FIXTURE
HANGER
FURNISHED
WITH
FIXTURE
B
B
FINISHED
WALL
FINISHED FLOOR
3"
FINISHED
FLOOR
4 1/2"
RECOMMEND ALL FEET BE SECURED TO FLOOR
WITH 1/2" BOLTS AND ANCHORS BY OTHERS.
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
MANUFACTURER
_______________
NUMBER
_______________
SIZE
_______________
NAME
_______________
3"
4 1/2"
RECOMMEND ALL FEET BE SECURED TO FLOOR
WITH 1/2" BOLTS AND ANCHORS BY OTHERS.
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
RIM HEIGHT________
X -WC WATER COOLER CARRIER
-10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS)
BASED ON "A" DIM SHOWN
57
DATE OF LAST CHANGE:
3/17/10
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
SIZE
_______________
DIMENSIONS
B _____________
C _____________
NUMBER
_______________
NAME
_______________
DIMENSIONS
X -UR URINAL CARRIER
-10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS)
MANUFACTURER
_______________
B _____________
C _____________
RIM HEIGHT________
BASED ON "A" DIM SHOWN
DATE OF LAST CHANGE:
3/18/10
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
58
SPECIFICATION:
JOSAM 17550-WCBL SERIES FLOOR-MOUNTED BI-LEVEL WATER
COOLER CARRIER WITH HANGER PLATES, ADJUSTABLE SUPPORTING
RODS, STRUCTURAL UPRIGHTS AND WELDED FEET.
WATER COOLER CARRIER
FLOOR-MOUNT HANGER PLATE
SERIES
REUSABLE ALIGNMENT TOOL AVAILABLE
1" MIN
3 3/8"
4" MAX
JOSAM 17550-CL SERIES FLOOR-MOUNTED, SINGLE LAVATORY
CARRIER FOR SUPPORTING CORNER TYPE LAVATORIES WITH
HANGER PLATE, ADJUSTABLE SUPPORTING RODS, STRUCTURAL
UPRIGHTS AND WELDED FEET.
17550-WCBL
C
FLOOR-MOUNT HANGER PLATE
1" MIN
4" MAX
FINISHED
WALL
3 5/8"
HANGERS FURNISHED
WITH FIXTURE
FINISHED
WALL
C
B
FINISHED
FLOOR
4 1/2"
3"
MANUFACTURER
_______________
RECOMMEND ALL FEET BE SECURED TO FLOOR
WITH 1/2" BOLTS AND ANCHORS BY OTHERS.
FINISHED
FLOOR
NUMBER
_______________
SIZE
_______________
3"
NAME
_______________
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C' = 18-1/4"
Fixture Carriers
UTILIZE A SINGLE ALIGNMENT TOOL TO ALIGN A PAIR OF
UPRIGHTS. IF YOU WISH TO BRACE ALL THREE UPRIGHTS
SIMULTANEOUSLY, TWO TOOLS ARE NECESSARY.
4 1/2"
RECOMMEND ALL FEET BE SECURED TO FLOOR
WITH 1/2" BOLTS AND ANCHORS BY OTHERS.
B _____________
C _____________
C'_____________
VARIABLE - DEPENDS ON FIXTURE
E _____________
RIM HEIGHT'________
-WCBL BI-LEVEL WATER COOLER CARRIER
-10
STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS)
3/19/10
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
BASED ON "E" DIM SHOWN
NOTES
MANUFACTURER
_______________
NUMBER
_______________
SIZE
_______________
NAME
_______________
DIMENSIONS
RIM HEIGHT________
B _____________
BASED ON "B" DIM SHOWN
DATE OF LAST CHANGE:
C
B
E
X
17550-CL
SERIES
2 3/8"
C'
LAVATORY CARRIER
SPECIFICATION:
X
-CL CORNER LAVATORY CARRIER
-10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS)
-60 VALVE PLATE FOR ATTACHING TO UPRIGHT
DATE OF LAST CHANGE:
3/26/10
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
C _____________
RIM HEIGHT________
BASED ON "A" DIM SHOWN
NOTES
Fixture Carriers
SPECIFICATION:
LAVATORY CARRIER
JOSAM 17560 SERIES FLOOR-MOUNTED, SINGLE LAVATORY CARRIER
WITH HANGER & BEARING PLATE, ADJUSTABLE SUPPORTING RODS,
STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM.
FLOOR-MOUNT BEARING PLATE
SERIES
REUSABLE ALIGNMENT TOOL AVAILABLE
SPECIFICATION:
JOSAM 17560-BB SERIES FLOOR-MOUNTED, BACK-TO-BACK LAVATORY
CARRIER WITH HANGER PLATES, ADJUSTABLE SUPPORTING RODS,
STRUCTURAL UPRIGHTS, WELDED FEET, AND CHROME PLATED TRIM.
17560
SERIES
17560-BB
2 1/2
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
1 MIN
4 MAX
2 1/2"
1 MIN
4 MAX
LAVATORY CARRIER
FLOOR-MOUNT HANGER PLATE
1 MIN
4 MAX
C
HANGERS
FURNISHED
WITH
FIXTURE
C
HANGER
FURNISHED
WITH FIXTURE
H
MANUFACTURER
_______________
H
NUMBER
_______________
SIZE
_______________
NAME
_______________
J
FINISHED
WALL
B
FINISHED
WALL
FINISHED
WALL
B
J
DIMENSIONS
B _____________
3"
C _____________
4 1/2
FINISHED FLOOR
H _____________
NUMBER
_______________
J _____________
FINISHED
FLOOR
RIM HEIGHT________
RECOMMEND ALL FEET BE SECURED TO FLOOR
WITH 1/2" BOLTS AND ANCHORS BY OTHERS.
BASED ON "A" DIM SHOWN
3"
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
4 1/2"
MANUFACTURER
_______________
REUSABLE ALIGNMENT TOOL AVAILABLE.
RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.
SIZE
_______________
NAME
_______________
DIMENSIONS
B _____________
C _____________
-BB
-UR
-WC
BACK-TO-BACK CARRIER
URINAL CARRIER
WATER COOLER CARRIER
-WCBL
WATER COOLER BI-LEVEL CARRIER*
-10
STUDS FOR WALLS OVER 4"
(SPECIFY WALL THICKNESS)
-60
VALVE PLATE FOR ATTACHING TO UPRIGHT
X
-BB BACK-TO-BACK CARRIER
-10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS)
-60 VALVE PLATE FOR ATTACHING TO UPRIGHT
H _____________
J _____________
RIM HEIGHT________
BASED ON "B" DIM SHOWN
SEPARATE SUBMITTAL FOR THIS OPTION AVAILABLE
59
DATE OF LAST CHANGE:
2/28/2014
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.


NOTES
DATE OF LAST CHANGE:
4/23/15
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
60
SPECIFICATION:
URINAL CARRIER
JOSAM 17560-UR SERIES FLOOR-MOUNTED, SINGLE URINAL CARRIER
WITH HANGER & BEARING PLATE, ADJUSTABLE SUPPORTING RODS,
STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM.
FLOOR-MOUNT BEARING PLATE
SERIES
REUSABLE ALIGNMENT TOOL AVAILABLE
JOSAM 17560-WC SERIES FLOOR-MOUNTED, SINGLE WATER COOLER
CARRIER WITH HANGER & BEARING PLATE, ADJUSTABLE SUPPORTING
RODS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED
TRIM.
17560-UR
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
2 1/2"
1 MIN
4 MAX
SPECIFICATION:
SERIES
REUSABLE ALIGNMENT TOOL AVAILABLE
E
H
C
HANGER
FURNISHED
WITH FIXTURE
FINISHED WALL
HANGER
FURNISHED
WITH FIXTURE
MANUFACTURER
_______________
MANUFACTURER
_______________
J
H
NUMBER
_______________
NUMBER
_______________
SIZE
_______________
SIZE
_______________
B
B
J
NAME
_______________
BEARING
STUDS
NOT
ATTACHED
TO FIXTURE
NAME
_______________
DIMENSIONS
B _____________
DIMENSIONS
C _____________
B _____________
BEARING
STUDS
NOT
ATTACHED
TO FIXTURE
C _____________
E _____________
FINISHED
FLOOR
17560-WC
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
2 1/2"
1 MIN
4 MAX
C
FINISHED WALL
WATER COOLER CARRIER
FLOOR-MOUNT BEARING PLATE
FINISHED
FLOOR
H _____________
J _____________
H _____________
J _____________
RIM HEIGHT________
BASED ON "A" DIM SHOWN
RIM HEIGHT________
BASED ON "A" DIM SHOWN
3"
3"
4 1/2"
Fixture Carriers
RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.
RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.
X -UR
-10
X -WC
URINAL CARRIER
HARDWARE FOR WALLS OVER 4",
SPECIFY WALL THICKNESS
DATE OF LAST CHANGE:
3/25/2014
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.


-10
NOTES
4 1/2"
WATER COOLER CARRIER
STUDS FOR WALLS OVER 4"
(SPECIFY WALL THICKNESS)
DATE OF LAST CHANGE:
11/10/2011
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
Fixture Carriers

SPECIFICATION:

JOSAM 17560-WCBL SERIES FLOOR-MOUNTED BI-LEVEL WATER
COOLER CARRIER WITH HANGER AND BEARING PLATES,
ADJUSTABLE SUPPORT RODS, STRUCTURAL UPRIGHTS, WELDED
FEET, AND CHROME-PLATED TRIM.
SERIES
MANUFACTURER _____________
B ____________
NUMBER
_____________
C ____________
SIZE
_____________
C' ____________
NAME
_____________
D
____________
E
____________
F
∆
1" MIN.
4" MAX.
3 1/2"
LAVATORY CARRIER
SPECIFICATION:
JOSAM 17590 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER
WITH HANGER PLATE AND ADJUSTABLE SUPPORTING RODS.
WALL-MOUNT HANGER PLATE
SERIES
17560-WCBL
____________
17590
1/4
______________
RIM HEIGHT BASED ON
'B' AND 'E' SHOWN
FINISHED
WALL
C
7 MAX
C'
FINISHED WALL
HANGER(S) FURNISHED
WITH FIXTURE
3 5/8"
MANUFACTURER
_______________
NUMBER
_______________
42 1/4"
B
SIZE
_______________
4
NAME
_______________
E
D
21 1/2
F
B
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
FINISHED
FLOOR
DIMENSIONS
B _____________
RIM HEIGHT________
BASED ON "B" DIM SHOWN
FINISHED FLOOR
3"
4 1/2"
RECOMMEND ALL FEET BE SECURED TO FLOOR
WITH 1/2" BOLTS AND ANCHORS BY OTHERS
USE SINGLE ALIGNMENT TOOL FOR PAIR OF UPRIGHTS
FOR ALIGNING ALL 3 UPRIGHTS, 2 TOOLS ARE NECESSARY
X
-WCBL
-10
BI-LEVEL WATER COOLER CARRIER
STUDS FOR WALLS OVER 4" (SPECIFY)
-DP
-UR
-10
DOUBLE PLATE CARRIER
URINAL CARRIER
STUDS FOR WALLS OVER 7" (SPECIFY WALL THICKNESS)
SEPARATE SUBMITTAL FOR THIS OPTION AVAILABLE
61
DATE OF LAST CHANGE:
05/15/14
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.


NOTES
DATE OF LAST CHANGE:
5/04/15
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
62
LAVATORY CARRIER
SPECIFICATION:
JOSAM 17590-DP SERIES WALL-MOUNTED, SINGLE LAVATORY
CARRIER WITH HANGER PLATES AND ADJUSTABLE SUPPORTING
RODS.
WALL-MOUNT HANGER PLATE
JOSAM 17590-UR SERIES WALL-MOUNTED, SINGLE URINAL CARRIER
WITH HANGER PLATE AND ADJUSTABLE SUPPORTING RODS.
17590-DP
SERIES
1/4
URINAL CARRIER
SPECIFICATION:
WALL-MOUNT HANGER PLATE
17590-UR
SERIES
1/4
4 (STANDARD)
7 MAX
1/2 MIN
FINISHED WALL
HANGER(S) FURNISHED
WITH FIXTURE
MANUFACTURER
_______________
FINISHED WALL
HANGER(S) FURNISHED
WITH FIXTURE
MANUFACTURER
_______________
NUMBER
_______________
SIZE
_______________
4
NUMBER
_______________
SIZE
_______________
4
NAME
_______________
21 1/2
NAME
_______________
21 1/2
DIMENSIONS
B
B _____________
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
RIM HEIGHT________
BASED ON "B" DIM SHOWN
Fixture Carriers
X
-DP
-10
DATE OF LAST CHANGE:
DOUBLE PLATE CARRIER
STUDS FOR WALLS OVER 7" (SPECIFY WALL THICKNESS)
5/04/15
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
B _____________
RIM HEIGHT________
BASED ON "B" DIM SHOWN
FINISHED FLOOR
FINISHED FLOOR
X
DIMENSIONS
B
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
NOTES
-UR
-10
DATE OF LAST CHANGE:
URINAL CARRIER
STUDS FOR WALLS OVER 7" (SPECIFY WALL THICKNESS)
5/04/15
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
Fixture Carriers
URINAL CARRIER
SPECIFICATION:
JOSAM 17590-DP SERIES WALL-MOUNTED, SINGLE URINAL
CARRIER WITH HANGER PLATES AND ADJUSTABLE SUPPORTING
RODS.
WALL-MOUNT HANGER PLATE
17590-UR-DP
SERIES
SINK CARRIER
SPECIFICATION:
JOSAM 17720 SERIES FLOOR-MOUNTED, SINGLE, HEAVY-DUTY SINK
CARRIER WITH HANGER PLATE, ADJUSTABLE SUPPORTING RODS,
ACID-RESISTING WHITE COATED ARMS, LEVELING AND SECURING
SCREWS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME
PLATED TRIM.
FLOOR-MOUNT HEAVY-DUTY
SERIES
17720
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
RECOMMEND ALL FEET BE SECURED
TO FLOOR WITH 1/2" BOLTS AND
ANCHOR BY OTHERS.
1 MIN
4 MAX
1/4
3 1/2"
C
4 (STANDARD)
1/2 MIN
MANUFACTURER
_______________
FINISHED WALL
HANGER(S) FURNISHED
WITH FIXTURE
MANUFACTURER
_______________
1 1/2"
NUMBER
_______________
NAME
_______________
21 1/2
A _____________
B _____________
A
B _____________
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
DIMENSIONS
C+4
OR
C-4
B
DIMENSIONS
B
SIZE
_______________
NAME
_______________
SIZE
_______________
4
NUMBER
_______________
RIM HEIGHT________
FINISHED
WALL
BASED ON "B" DIM SHOWN
C _____________
RIM HEIGHT________
BASED ON "A&B" DIM SHOWN
FINISHED FLOOR
3"
4 1/2"
X
X
-DP
-UR
-10
63
DATE OF LAST CHANGE:
DOUBLE PLATE CARRIER
URINAL CARRIER
STUDS FOR WALLS OVER 7" (SPECIFY WALL THICKNESS)
5/04/15
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
-VP
-10
-66
FINISHED
FLOOR
VANDAL-PROOF TRIM
STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS)
SPLIT HEADER FOR STAINLESS STEEL ARMS (SEPERATE SUBMITTAL AVAILABLE
DATE OF LAST CHANGE:
4/23/15
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
64
SINK CARRIER
SPECIFICATION:
JOSAM 17720-66 SERIES FLOOR-MOUNTED, SINGLE, HEAVY-DUTY SINK
CARRIER WITH HANGER PLATE, ADJUSTABLE SUPPORTING RODS,
BEARING STUDS, STRUCTURAL UPRIGHTS, WELDED FEET AND
CHROME PLATED TRIM.
FLOOR-MOUNT HEAVY-DUTY
SERIES
SINK CARRIER
SPECIFICATION:
JOSAM 17730 SERIES FLOOR-MOUNTED, SINGLE, HEAVY-DUTY SINK
CARRIER WITH SUPPORT PLATES, ADJUSTABLE COUPLING WITH 4"
PIPING CONNECTION, MOUNTING STUDS, STRUCTURAL UPRIGHTS,
WELDED FEET AND CHROME PLATED TRIM.
17720-66
FLOOR-MOUNT HEAVY-DUTY
17730
SERIES
VARIABLE - DEPENDS ON FIXTURE
EXCEPT WHEN STANDARD PLATE IS
FURNISHED C = 18-1/4"
NOTES
1.
RECOMMEND ALL FEET BE SECURED
TO FLOOR WITH 1/2" BOLTS AND
ANCHOR BY OTHERS.
2.
3 1/2"
DIMENSIONS MARKED
VARY DEPENDING
ON MOUNTED FIXTURE.
RECOMMEND FEET BE
SECURED TO FLOOR
WITH 1/2" BOLTS & ANCHORS
BY OTHERS.
1" MIN
4" MAX
C
19"
C
D
MANUFACTURER
_______________
5/8"-11 THREADED
OR 1/2" THRU HOLE
NUMBER
_______________
C+4
OR
C-4
NUMBER
_______________
NAME
_______________
4 1/8"
B _____________
C _____________
FINISHED
WALL
42 1/4"
B
Fixture Carriers
4/23/15
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
C _____________
D_____________
E_____________
NOTES
RIM HEIGHT________
FINISHED
WALL
FINISHED
FLOOR
VANDAL-PROOF TRIM
STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS)
SPLIT HEADER FOR STAINLESS STEEL ARMS (SEPERATE SUBMITTAL AVAILABLE
DATE OF LAST CHANGE:
B _____________
BASED ON "B" DIM SHOWN
4 1/2"
-VP
-10
-66
NAME
_______________
4" THREADED
OUTLET
CONNECTION
RIM HEIGHT________
3"
4 1/2"
SIZE
_______________
REVERSE THESE
TWO PLATES
FOR BLOWOUT
FIXTURES WITH
THREE BOLT
MOUNT
E
H _____________
X
MANUFACTURER
_______________
SIZE
_______________
H
DIMENSIONS
B
3 3/8"
1 1/2" MIN
6 1/8" MAX
-VP
-11
-60
FINISHED
FLOOR
BASED ON "B" DIM SHOWN
3"
VANDAL-PROOF TRIM
CAST IRON ADJUSTABLE EXTENSION (SPECIFY 6", 9" OR 12" ON ORDER)
VALVE PLATE FOR ATTACHING TO UPRIGHT
DATE OF LAST CHANGE:
4/23/15
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES
Fixture Carriers
SINK CARRIER
SPECIFICATION:
JOSAM 17735 SERIES FLOOR-MOUNTED, SINGLE, HEAVY-DUTY SINK
CARRIER WITH SUPPORT PLATES, ADJUSTABLE COUPLING WITH
4" X 2" WASTE FITTING, MOUNTING STUDS, STRUCTURAL UPRIGHTS,
WELDED FEET AND CHROME PLATED TRIM.
FLOOR-MOUNT HEAVY-DUTY
17735
SERIES
-45 (OPTION)
-46 (OPTION)
NOTES
7 5/8"
1.
4"
2.
DIMENSIONS MARKED
VARY DEPENDING
ON MOUNTED FIXTURE.
RECOMMEND FEET BE
SECURED TO FLOOR
WITH 1/2" BOLTS & ANCHORS
BY OTHERS.
19"
3 3/8"
C=15 3/4"
7/8" MIN
5 3/8" MAX
D
5/8"-11 THREADED
OR 1/2" THRU HOLE
MANUFACTURER
_______________
CUT EXTENSION
AS NEEDED
E
NUMBER
_______________
SIZE
_______________
REVERSE THESE
TWO PLATES
FOR BLOWOUT
FIXTURES WITH
THREE BOLT
MOUNT
*
42 1/4"
B
NAME
_______________
B _____________
C _____________
4" THREADED
OUTLET
CONNECTION
D_____________
E/G___________
RIM HEIGHT________
BASED ON "B" DIM SHOWN
FINISHED
WALL
4 1/2"
*G
FINISHED
FLOOR
3"
FOR BLOWOUT CONFIGURATION
-4
-10
-45
-46
VANDAL-PROOF TRIM
STUDS FOR WALLS OVER 5-3/8" (SPEC. WALL THICKNESS)
THREADED HIGH LEFT-HAND AUXILIARY VENT
THREADED HIGH RIGHT-HAND AUXILIARY VENT
NOTE: OTHER FITTINGS AVAILABLE UPON REQUEST. CONTACT YOUR JOSAM REPRESENTATIVE
65
DATE OF LAST CHANGE:
4/23/15
DIMENSIONS ARE SUBJECT TO MANUFACTURERS
TOLERANCES AND CHANGE WITHOUT NOTICE.
WE CAN ASSUME NO RESPONSIBILITY FOR
USE OF SUPERSEDED OR VOID DATA.
JOSAM COMPANY
MICHIGAN CITY, INDIANA
NOTES