concealed type lavatory carrier
Transcription
concealed type lavatory carrier
Fixture Carriers CONCEALED TYPE LAVATORY CARRIER 1. Tandem keepers in slots on the arm permit positioning of leveling screws on the job to suit punchings of any lavatory specified. 2. Screws in keepers can then easily be moved up or down to level the lavatory. 3. The securing lock device is positioned on the arm and tightens against the fixture to hold it rigidly in place. 4. The sleeve can be adjusted to suit various wall thicknesses. 5. The final setting of the arm out from the wall can be made from the face of the finished wall after the wall is built. 6. The set screws are easily accessible for quicker adjustment. 7. Arm with the locking device, tandem keepers, and adjustable sleeve, is completely assembled at the factory. 8. Hardware is plated to prevent corrosion. Detail of securing method for concealed arm carrier. Detail of leveling arrangement for concealed arm carrier. Detail of parts of concealed arm carrier in or behind finished wall. 45 Detail of parts of concealed arm carrier. For roughing dimensions for specific fixtures, please refer to the Josam website, www.josam.com. 46 Parts & Details Lavatory, Sink & Urinal Carriers The drawings on this page show the relationship between mating parts of carriers covered in this section. Fixture Carriers (-66) OPTION, SPLIT HEADER FOR STAINLESS STEEL ARMS In many cases arms are supplied by the manufacturers of stainless steel fixtures. The mounting hole spacing in the back of the arm (Y Dim.) varies widely by sink and manufacturer. The -66 split header is adjustable to allow for the mounting of this type of sink and arm combination. (-75) OPTION, 2” ESCUTCHEONS (-76) OPTION, 4” ESCUTCHEONS Escutcheons provide manufacturers’ specified distance from wall to back of a slab type lavatory to prevent water from deteriorating finished wall when concealed arms are used. Furnished in polished chrome. (-77) OPTION, 6” ESCUTCHEONS also available. Fixture Carriers 47 48 FIXTURE CARRIER SPECIFICATION: JOSAM 17000 SERIES RE-USABLE ALIGNMENT TOOL FOR FLOOR MOUNTED FIXTURE CARRIERS WITH UPRIGHTS. REUSABLE ALIGNMENT TOOL SERIES 17000 LAVATORY CARRIER SPECIFICATION: JOSAM 17100 SERIES FLOOR-MOUNTED, SINGLE LAVATORY CARRIER WITH CONCEALED ARMS, LEVELING AND SECURING SCREWS, STRUCTURAL UPRIGHTS, AND WELDED FEET. FLOOR-MOUNT CONCEALED ARM SERIES : VARIABLE DIMENSION. DEPENDS ON FIXTURE. REUSABLE ALIGNMENT TOOL AVAILABLE. 17100 -BB BACK-TO-BACK CARRIER (SEPARATE SUBMITTAL FOR THIS OPTION AVAILABLE) -10 EXTENSION SLEEVES LONGER THAN STANDARD (SPECIFY WALL THICKNESS) -60 VALVE PLATE FOR ATTACHING TO UPRIGHT C" 29" 8" -67 CONCEALED ARM CARRIER FOR WHEELCHAIR LAVATORY -75 2" CHROME PLATED ESCUTCHEONS -76 4" CHROME PLATED ESCUTCHEONS -77 6" CHROME PLATED ESCUTCHEONS 3 3/8" 2" STANDARD ADJUSTABLE SLEEVE 6-1/2" -75 OPTION SHOWN: 2" ESCUTCHEON 3 1/8" 1/2" MIN 4" MAX ALIGNMENT TOOL POSITIONED FOR UPRIGHT SPACING AT TIE ROD ESCUTCHEON FINISHED WALL F" 2" C" MANUFACTURER _______________ NUMBER _______________ SIZE _______________ 1 1/2" NAME _______________ FINISHED WALL A" DIMENSIONS A _____________ Fixture Carriers ALIGNMENT TOOL POSITIONED FOR UPRIGHT SPACING AT FLOOR 3" EXAMPLE VIEW 04/21/08 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA F _____________ RIM HEIGHT________ *CARRIER NOT INCLUDED DATE OF LAST CHANGE: C _____________ FINISHED FLOOR NOTES DATE OF LAST CHANGE: 4 1/2" JOSAM RECOMMENDS THAT ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS 06/18/08 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA BASED ON "A" DIM SHOWN REFERENCE DRAWING A-08201-K NOTES Fixture Carriers SPECIFICATION: JOSAM 17100-BB SERIES FLOOR-MOUNTED, BACK-TO-BACK LAVATORY CARRIER WITH CONCEALED ARMS, LEVELING AND SECURING SCREWS, STRUCTURAL UPRIGHTS AND WELDED FEET. LAVATORY CARRIER FLOOR-MOUNT CONCEALED ARM SPECIFICATION: JOSAM 17120 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER WITH CONCEALED ARMS, LEVELING AND SECURING SCREWS, AND ADJUSTABLE WALL PLATE. 17100-BB SERIES SIZE _______________ C" WALL-MOUNT CONCEALED ARM 17120 SERIES MANUFACTURER _______________ NUMBER _______________ LAVATORY CARRIER 2" 2 3/4" 1 1/2" F C (13" MIN-22.5" MAX) 5" NAME _______________ DIMENSIONS FINISHED WALL A _____________ 2" C _____________ F _____________ F" F" 5" MIN 12" MAX 1 1/2" 1 1/2" RIM HEIGHT __________ 1 1/2" BASED ON "A" DIM SHOWN X -BB A BACK TO BACK CARRIER -10 EXTENSION SLEEVES LONGER THAN STANDARD (SPECIFY WALL THICKNESS) -60 VALVE PLATE FOR ATTACHING TO UPRIGHT FINISHED WALL FINISHED FLOOR DENOTES VARIABLE. DIMENSION DEPENDS ON FIXTURE. STANDARD ADJUSTABLE SLEEVE IS 4" LONG CONCEALED ARM CARRIER -67 FOR WHEEL CHAIR LAVATORY 3 1/2" FINISHED WALL FINISHED WALL 2" CHROME PLATED ESCUTCHEONS -76 4" CHROME PLATED ESCUTCHEONS -77 6" CHROME PLATED ESCUTCHEONS 2" A" : VARIABLE DIMENSION. DEPENDS ON FIXTURE. REUSABLE ALIGNMENT TOOL AVAILABLE. FINISHED FLOOR 49 DATE OF LAST CHANGE: 06/18/08 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY -BP* -MMB* WITH BACK PLATES WITH MOVABLE MOUNTING BRACKETS -10* EXTENSION SLEEVES LONGER THAN STANDARD (SPECIFY WALL THICKNESS) -75 -76 -77 2" CHROME PLATED ESCUTCHEONS 4" CHROME PLATED ESCUTCHEONS 6" CHROME PLATED ESCUTCHEONS NOTES NUMBER _______________ SIZE _______________ NAME _______________ DIMENSIONS A _____________ * SEPARATE SUBMITTAL FOR THIS OPTION AVAILABLE RIM HEIGHT ________ BASED ON "A" DIM SHOWN REFERENCE DRAWING A-08202-K DATE OF LAST CHANGE: C _____________ F _____________ -75 OPTION CHROME PLATED ESCUTCHEON JOSAM RECOMMENDS THAT ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS MICHIGAN CITY, INDIANA 5" STANDARD ADJUSTABLE SLEEVE 6-1/2" -75 OPTION SHOWN: 2" ESCUTCHEON 3" MANUFACTURER _______________ 2" 2 3/4" ESCUTCHEON FINISHED WALL -75 02/21/14 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. NOTES 50 LAVATORY CARRIER SPECIFICATION: WALL-MOUNT CONCEALED ARM JOSAM 17120-10 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER WITH CONCEALED ARMS, LEVELING AND SECURING SCREWS, AND ADJUSTABLE WALL PLATE. SERIES 17120-10 LAVATORY CARRIER SPECIFICATION: WALL-MOUNT CONCEALED ARM JOSAM 17120-BP SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER WITH CONCEALED ARMS, LEVELING AND SECURING SCREWS, ADJUSTABLE WALL PLATE AND BACK PLATE. SERIES 17120-BP 6" MAX F 1" MIN 1 1/2" 6" MAX C 1 1/2" F 5" C 5" FINISHED WALL 1 1/2" 1 1/2" FINISHED WALL A A FINISHED WALL FINISHED FLOOR FINISHED FLOOR DENOTES VARIABLE DIMENSION DEPENDS ON FIXTURE. STANDARD ADJUSTABLE SLEEVE IS 8-1/2" LONG FINISHED WALL 1" MIN MANUFACTURER _______________ 2" F MANUFACTURER _______________ 2" NUMBER _______________ 6" MAX NUMBER _______________ SIZE _______________ NAME _______________ Fixture Carriers 5" DIMENSIONS X -75 OPTION CHROME PLATED ESCUTCHEON DATE OF LAST CHANGE: -BP WITH BACK PLATES A _____________ -10 EXTENSION SLEEVES LONGER THAN STANDARD (SPECIFY WALL THICKNESS) C _____________ -75 -76 -77 06/18/08 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. 2" CHROME PLATED ESCUTCHEONS 4" CHROME PLATED ESCUTCHEONS 6" CHROME PLATED ESCUTCHEONS JOSAM COMPANY MICHIGAN CITY, INDIANA X -BP -10 F _____________ -75 -76 -77 RIM HEIGHT ________ BASED ON DIM. "A" SHOWN NOTES DENOTES VARIABLE DIMENSION DEPENDS ON FIXTURE. STANDARD ADJUSTABLE SLEEVE 8-1/2" -75 OPTION CHROME PLATED ESCUTCHEON DATE OF LAST CHANGE: SIZE _______________ NAME _______________ DIMENSIONS WITH BACK PLATES EXTENSION SLEEVES LONGER THAN STANDARD (SPECIFY WALL THICKNESS) 2" CHROME PLATED ESCUTCHEONS 4" CHROME PLATED ESCUTCHEONS 6" CHROME PLATED ESCUTCHEONS 06/18/08 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA A _____________ C _____________ F _____________ RIM HEIGHT_________ BASED ON "A" DIM. SHOWN NOTES Fixture Carriers LAVATORY CARRIER SPECIFICATION: JOSAM 17120-MMB SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER WITH CONCEALED ARMS, LEVELING AND SECURING SCREWS, AND MOVABLE MOUNTING BRACKETS FOR SECURING TO WALL PLATE BY OTHERS. WALL-MOUNT CONCEALED ARM 17120-203-H SERIES REF. NO.: M1456 PLATE FURNISHED BY OTHERS 11/16" 1 1/2" 1 1/4" F WALL-MOUNT CONCEALED ARM JOSAM 17120 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER WITH CONCEALED ARMS, LEVELING AND SECURING SCREWS, AND ADJUSTABLE WALL PLATE 17120-MMB SERIES 1 1/4" MIN 2 1/2" MAX LAVATORY CARRIER SPECIFICATION: 2" 1 1/4" 1 1/2" ADJUSTABLE 16 5/8" C 2" 5" 1 1/2" 14 1/2" MAX. C 5" 1 1/2" A FINISHED WALL FINISHED FLOOR FINISHED WALL 7/8" (4) SECURING HOLES FOR 1/2" BOLTS FINISHED WALL MANUFACTURER _______________ F NUMBER _______________ 3 3/4" SIZE _______________ DENOTES VARIABL DIMENSION DEPENDS ON FIXTURE STANDARD ADJUSTABLE SLEEVE IS 6 1/2" 2" -75 OPTION CHROME PLATED ESCUTCHEON 51 DATE OF LAST CHANGE: X -MMB 06/18/08 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. WITH MOVABLE MOUNTING BRACKETS -10 EXTENSION SLEEVES LONGER THAN STANDARD (SPECIFY WALL THICKNESS) -75 -76 -77 2" CHROME PLATED ESCUTCHEONS 4" CHROME PLATED ESCUTCHEONS 6" CHROME PLATED ESCUTCHEONS JOSAM COMPANY MICHIGAN CITY, INDIANA NAME _______________ DIMENSIONS A _____________ C _____________ F _____________ RIM HEIGHT_________ BASED ON "A" DIM. SHOWN NOTES DATE OF LAST CHANGE: 06/03/08 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES 52 SPECIFICATION: JOSAM 17125 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER WITH CONCEALED ARMS, LEVELING & SECURING SCREWS AND STEEL PLATE FOR ATTACHING TO STUDS. LAVATORY CARRIER WALL-MOUNT CONCEALED ARM SPECIFICATION: JOSAM 17380 SERIES FLOOR-MOUNTED, SINGLE LAVATORY CARRIER WITH EXPOSED ACID-RESISTING WHITE COATED ARMS, LEVELING AND SECURING SCREWS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM. 17125 SERIES LAVATORY CARRIER FLOOR-MOUNT EXPOSED ARM 17380 SERIES REUSABLE ALIGNMENT TOOL AVAILABLE "X" 4 1/2" FINISHED WALL C FINISHED WALL C 2" 1/2" MIN 1 3/8" MAX 1 1/2" 1" MIN 4 1/2" MAX 2 1/2" : VARIABLE DIMENSION. DEPENDS ON FIXTURE. STANDARD ADJUSTABLE SLEEVE IS 4". 1 1/2" MANUFACTURER 4" "X" 12 1/2" 15 1/2" 12 1/2" 2" : VARIABLE DIMENSION. DEPENDS ON FIXTURE. STANDARD ADJUSTABLE SLEEVE IS 4". F MODEL -201 -203 -507P NUMBER A FINISHED FLOOR 1/2" MIN 1 3/8" MAX F A C Fixture Carriers F 4" 3 1/8" NUMBER NAME DIMENSIONS 2" MANUFACTURER SIZE FINISHED WALL FINISHED FLOOR EXTENSION SLEEVES LONGER THAN STANDARD (SPECIFY WALL THICKNESS) 2" CHROME PLATED ESCUTCHEONS DATE OF LAST CHANGE: 4/23/15 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES C -BB BACK-TO-BACK CARRIER -10 -HD HEAVY-DUTY -60 VALVE PLATE FOR ATTACHING TO UPRIGHT -VP VANDAL-PROOF TRIM -66 SPLIT HEADER FOR STAINLESS STEEL ARMS DATE OF LAST CHANGE: DIMENSIONS A 3" BASED ON "A" DIM SHOWN -10 -75 SIZE NAME RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. RIM HEIGHT CHROME PLATED ESCUTCHEONS (-75) A 4/23/15 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. STUDS FOR WALLS OVER 4-1/2" (SPEC. WALL THICKNESS) JOSAM COMPANY MICHIGAN CITY, INDIANA RIM HEIGHT BASED ON "A" DIM SHOWN NOTES Fixture Carriers SPECIFICATION: JOSAM 17380-BB SERIES FLOOR-MOUNTED, BACK-TO-BACK LAVATORY CARRIER WITH EXPOSED ACID-RESISTING WHITE COATED ARMS, LEVELING AND SECURING SCREWS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM. LAVATORY CARRIER FLOOR-MOUNT EXPOSED ARM 17380-BB SERIES REUSABLE ALIGNMENT TOOL AVAILABLE SINK CARRIER SPECIFICATION: JOSAM 17380-HD SERIES FLOOR-MOUNTED, SINGLE HEAVY-DUY SINK CARRIER WITH EXPOSED ACID-RESISTING WHITE COATED ARMS, LEVELING AND SECURING SCREWS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM. FLOOR-MOUNT EXPOSED ARM SERIES REUSABLE ALIGNMENT TOOL AVAILABLE "X" - 201 - 203 MANUFACTURER X = 16" X = 20" MANUFACTURER _______________ _______________ NUMBER C _______________ SIZE SIZE NAME _______________ 2" A ____________ NAME 1 MIN 4-1/2 MAX _______________ 5 MIN 12 MAX NUMBER FINISHED WALL C _______________ _______________ 2" _______________ 1 1/2" 3 1/2" A ____________ C ____________ C ____________ ____________ F ____________ BASED RIM HEIGHT ON 'A' DIM SHOWN RIM HEIGHT BASED ON 'A' DIM SHOWN 1 1/2" 3 1/4" 3 1/2" FINISHED WALL OFFSET ARMS FURNISHED WHEN REQUIRED FINISHED WALL A FINISHED FLOOR FINISHED WALL F VARIABLE DEPENDS ON FIXTURE 53 DATE OF LAST CHANGE: 7/16/09 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. X -BB BACK-TO-BACK CARRIER -VP VANDAL-PROOF TRIM -10 STUDS FOR WALLS OVER 12" (SPECIFY WALL THICKNESS) -60 VALVE PLATE FOR ATTACHING TO UPRIGHT JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES VARIABLE DEPENDS ON FIXTURE A RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. FINISHED FLOOR 3" RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. 17380-HD 3" X -HD HEAVY-DUTY -BB BACK-TO-BACK CARRIER -VP VANDAL-PROOF TRIM DATE OF LAST CHANGE: 09/15/09 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. -10 STUDS FOR WALLS OVER 4-1/2" (SPEC. WALL THICKNESS) -60 -66 VALVE PLATE FOR ATTACHING TO UPRIGHT SPLIT HEADER FOR STAINLESS STEEL ARMS JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES 54 SINK CARRIER SPECIFICATION: JOSAM 17380-BB-HD SERIES FLOOR-MOUNTED, BACK-TO-BACK HEAVY-DUTY SINK CARRIER WITH EXPOSED ACID-RESISTING WHITE COATED ARMS, LEVELING AND SECURING SCREWS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM. FLOOR-MOUNT EXPOSED ARM SERIES REUSABLE ALIGNMENT TOOL AVAILABLE SPECIFICATION: JOSAM 17390 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER WITH EXPOSED ACID-RESISTING WHITE COATED ARMS, LEVELING AND SECURING SCREWS, ADJUSTABLE WALL PLATE AND CHROME PLATED TRIM. 17380-BB-HD 1 1/2" MANUFACTURER _______________ 1 1/2" SIZE 5" FINISHED WALL _______________ NAME 6 MIN 13 MAX FINISHED WALL _______________ 1 1/2" C NUMBER _______________ 2" 17390 SERIES 4 1/2 C LAVATORY CARRIER WALL-MOUNT EXPOSED ARM A A ____________ C ____________ F ____________ 4 1/2" FINISHED WALL FINISHED FLOOR RIM HEIGHT 'F' BASED ON 'A' DIM SHOWN FINISHED WALL A MANUFACTURER _______________ VARIABLE DEPENDS ON FIXTURE NUMBER _______________ 3 1/4" Fixture Carriers FINISHED FLOOR RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. 3" X X -BB BACK-TO-BACK CARRIER -HD HEAVY-DUTY -VP VANDAL-PROOF TRIM DATE OF LAST CHANGE: 8/17/09 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. OFFSET ARM FURNISHED WHEN REQUIRED. DENOTES VARIABLE DIMENSION DEPENDS ON FIXTURE. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES NAME _______________ DIMENSIONS A _____________ C _____________ -BP WITH BACK PLATES* -10 STUDS FOR WALLS OVER 13" (SPECIFY WALL THICKNESS) -60 VALVE PLATE FOR ATTACHING TO UPRIGHT -66 SPLIT HEADER FOR STAINLESS STEEL ARMS SIZE _______________ RIM HEIGHT_________ -VP VANDAL-PROOF TRIM BASED ON "A" DIM. SHOWN -10 STUDS FOR WALLS OVER 4-1/2" (SPEC. WALL THICKNESS) * SEPERATE SUBMITTAL FOR THIS OPTION AVAILABLE DATE OF LAST CHANGE: 2/23/10 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES Fixture Carriers SPECIFICATION: JOSAM 17390 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER WITH EXPOSED ACID-RESISTING WHITE COATED ARMS, LEVELING AND SECURING SCREWS, ADJUSTABLE WALL PLATE, BACK PLATES AND CHROME PLATED TRIM. LAVATORY CARRIER WALL-MOUNT EXPOSED ARM 4 1/2" 1 1/4" MIN JOSAM 17405 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER WITH EXPOSED ACID-RESISTING WHITE COATED ARMS, LEVELING AND SECURING SCREWS, MOUNTING RODS FOR SECURING TO WALL PLATE BY OTHERS AND CHROME PLATED TRIM. 17390-BP SERIES 1 1/2" SPECIFICATION: 17405 SERIES PLATE FURNISHED BY OTHERS 1 1/2" MIN 1 7/8" MAX C LAVATORY CARRIER WALL-MOUNT EXPOSED ARM 11/16" 1 1/4" 1 1/4" 1 1/2" 5" C 1 1/2" FINISHED WALL A FINISHED WALL FINISHED WALL FINISHED WALL A FINISHED FLOOR FINISHED FLOOR MANUFACTURER _______________ DENOTES VARIABLE DIMENSION DEPENDS ON FIXTURE. NUMBER 3 1/4" _______________ NUMBER _______________ SIZE _______________ NAME _______________ 3 1/4" X -BP -VP -10 DIMENSIONS NAME _______________ DENOTES VARIABLE DIMENSION DEPENDS ON FIXTURE. DIMENSION BASED ON 1/4" PLATE BY OTHERS. C _____________ WITH BACK PLATES* VANDAL-PROOF TRIM STUDS FOR WALLS OVER 4-1/2" (SPEC. WALL THICKNESS) SIZE _______________ OFFSET ARM FURNISHED WHEN REQUIRED. A _____________ OFFSET ARM FURNISHED WHEN REQUIRED. MANUFACTURER _______________ RIM HEIGHT_________ BASED ON "A" DIM. SHOWN -VP VANDAL-PROOF TRIM -10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS) DIMENSIONS A _____________ C _____________ RIM HEIGHT_________ BASED ON "A" DIM. SHOWN *SEPARATE SUBMITTAL FOR THIS OPTION AVAILABLE 55 DATE OF LAST CHANGE: 3/04/10 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES DATE OF LAST CHANGE: 3/05/10 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES 56 LAVATORY CARRIER SPECIFICATION: JOSAM 17550 SERIES FLOOR-MOUNTED, SINGLE LAVATORY CARRIER WITH HANGER PLATE, ADJUSTABLE SUPPORTING RODS, STRUCTURAL UPRIGHTS AND WELDED FEET. FLOOR-MOUNT HANGER PLATE SERIES REUSABLE ALIGNMENT TOOL AVAILABLE SPECIFICATION: JOSAM 17550-BB SERIES FLOOR-MOUNTED, BACK-TO-BACK LAVATORY CARRIER WITH HANGER PLATES, ADJUSTABLE SUPPORTING RODS, STRUCTURAL UPRIGHTS AND WELDED FEET. 17550 SERIES VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" 1 MIN 4 MAX C 1 MIN 4 MAX C MANUFACTURER _______________ HANGER FURNISHED WITH FIXTURE FINISHED WALL 17550-BB 2 1/2 2 1/2" 1 MIN 4 MAX LAVATORY CARRIER FLOOR-MOUNT HANGER PLATE NUMBER _______________ SIZE _______________ B FINISHED WALL FINISHED WALL NAME _______________ B HANGERS FURNISHED WITH FIXTURE DIMENSIONS B _____________ 3" C _____________ BASED ON "A" DIM SHOWN FINISHED FLOOR 4 1/2 FINISHED FLOOR RIM HEIGHT________ MANUFACTURER _______________ 3" 4 1/2" RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. NUMBER _______________ VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" SIZE _______________ Fixture Carriers RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. -BB -CL -UR -WC BACK-TO-BACK CARRIER* CORNER LAVATORY CARRIER* URINAL CARRIER* WATER COOLER CARRIER* -WCBL WATER COOLER BI-LEVEL CARRIER* -10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS) -60 VALVE PLATE FOR ATTACHING TO UPRIGHT NAME _______________ DIMENSIONS X -BB BACK-TO-BACK CARRIER -10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS) -60 VALVE PLATE FOR ATTACHING TO UPRIGHT B _____________ C _____________ RIM HEIGHT________ BASED ON "B" DIM SHOWN *SEPARATE SUBMITTAL FOR THIS OPTION AVAILABLE DATE OF LAST CHANGE: 8/11/2009 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES DATE OF LAST CHANGE: 3/27/12 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES Fixture Carriers URINAL CARRIER SPECIFICATION: JOSAM 17550-UR SERIES FLOOR-MOUNTED, SINGLE URINAL CARRIER WITH HANGER PLATE, ADJUSTABLE SUPPORTING RODS, STRUCTURAL UPRIGHTS AND WELDED FEET. FLOOR-MOUNT HANGER PLATE FINISHED WALL WATER COOLER CARRIER FLOOR-MOUNT HANGER PLATE 17550-WC SERIES 1" MIN 4" MAX 2 1/2" C 1" MIN 4" MAX PLATE PUNCHED FOR USE WITH BACK SUPPLY FIXTURE JOSAM 17550-WC SERIES FLOOR-MOUNTED, SINGLE WATER COOLER CARRIER WITH HANGER PLATE, ADJUSTABLE SUPPORTING RODS, STRUCTURAL UPRIGHTS AND WELDED FEET. 17550-UR SERIES REUSABLE ALIGNMENT TOOL AVAILABLE 2 1/2" SPECIFICATION: C HANGER FURNISHED WITH FIXTURE HANGER FURNISHED WITH FIXTURE B B FINISHED WALL FINISHED FLOOR 3" FINISHED FLOOR 4 1/2" RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" MANUFACTURER _______________ NUMBER _______________ SIZE _______________ NAME _______________ 3" 4 1/2" RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" RIM HEIGHT________ X -WC WATER COOLER CARRIER -10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS) BASED ON "A" DIM SHOWN 57 DATE OF LAST CHANGE: 3/17/10 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES SIZE _______________ DIMENSIONS B _____________ C _____________ NUMBER _______________ NAME _______________ DIMENSIONS X -UR URINAL CARRIER -10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS) MANUFACTURER _______________ B _____________ C _____________ RIM HEIGHT________ BASED ON "A" DIM SHOWN DATE OF LAST CHANGE: 3/18/10 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES 58 SPECIFICATION: JOSAM 17550-WCBL SERIES FLOOR-MOUNTED BI-LEVEL WATER COOLER CARRIER WITH HANGER PLATES, ADJUSTABLE SUPPORTING RODS, STRUCTURAL UPRIGHTS AND WELDED FEET. WATER COOLER CARRIER FLOOR-MOUNT HANGER PLATE SERIES REUSABLE ALIGNMENT TOOL AVAILABLE 1" MIN 3 3/8" 4" MAX JOSAM 17550-CL SERIES FLOOR-MOUNTED, SINGLE LAVATORY CARRIER FOR SUPPORTING CORNER TYPE LAVATORIES WITH HANGER PLATE, ADJUSTABLE SUPPORTING RODS, STRUCTURAL UPRIGHTS AND WELDED FEET. 17550-WCBL C FLOOR-MOUNT HANGER PLATE 1" MIN 4" MAX FINISHED WALL 3 5/8" HANGERS FURNISHED WITH FIXTURE FINISHED WALL C B FINISHED FLOOR 4 1/2" 3" MANUFACTURER _______________ RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. FINISHED FLOOR NUMBER _______________ SIZE _______________ 3" NAME _______________ VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C' = 18-1/4" Fixture Carriers UTILIZE A SINGLE ALIGNMENT TOOL TO ALIGN A PAIR OF UPRIGHTS. IF YOU WISH TO BRACE ALL THREE UPRIGHTS SIMULTANEOUSLY, TWO TOOLS ARE NECESSARY. 4 1/2" RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. B _____________ C _____________ C'_____________ VARIABLE - DEPENDS ON FIXTURE E _____________ RIM HEIGHT'________ -WCBL BI-LEVEL WATER COOLER CARRIER -10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS) 3/19/10 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA BASED ON "E" DIM SHOWN NOTES MANUFACTURER _______________ NUMBER _______________ SIZE _______________ NAME _______________ DIMENSIONS RIM HEIGHT________ B _____________ BASED ON "B" DIM SHOWN DATE OF LAST CHANGE: C B E X 17550-CL SERIES 2 3/8" C' LAVATORY CARRIER SPECIFICATION: X -CL CORNER LAVATORY CARRIER -10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS) -60 VALVE PLATE FOR ATTACHING TO UPRIGHT DATE OF LAST CHANGE: 3/26/10 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA C _____________ RIM HEIGHT________ BASED ON "A" DIM SHOWN NOTES Fixture Carriers SPECIFICATION: LAVATORY CARRIER JOSAM 17560 SERIES FLOOR-MOUNTED, SINGLE LAVATORY CARRIER WITH HANGER & BEARING PLATE, ADJUSTABLE SUPPORTING RODS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM. FLOOR-MOUNT BEARING PLATE SERIES REUSABLE ALIGNMENT TOOL AVAILABLE SPECIFICATION: JOSAM 17560-BB SERIES FLOOR-MOUNTED, BACK-TO-BACK LAVATORY CARRIER WITH HANGER PLATES, ADJUSTABLE SUPPORTING RODS, STRUCTURAL UPRIGHTS, WELDED FEET, AND CHROME PLATED TRIM. 17560 SERIES 17560-BB 2 1/2 VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" 1 MIN 4 MAX 2 1/2" 1 MIN 4 MAX LAVATORY CARRIER FLOOR-MOUNT HANGER PLATE 1 MIN 4 MAX C HANGERS FURNISHED WITH FIXTURE C HANGER FURNISHED WITH FIXTURE H MANUFACTURER _______________ H NUMBER _______________ SIZE _______________ NAME _______________ J FINISHED WALL B FINISHED WALL FINISHED WALL B J DIMENSIONS B _____________ 3" C _____________ 4 1/2 FINISHED FLOOR H _____________ NUMBER _______________ J _____________ FINISHED FLOOR RIM HEIGHT________ RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. BASED ON "A" DIM SHOWN 3" VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" 4 1/2" MANUFACTURER _______________ REUSABLE ALIGNMENT TOOL AVAILABLE. RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. SIZE _______________ NAME _______________ DIMENSIONS B _____________ C _____________ -BB -UR -WC BACK-TO-BACK CARRIER URINAL CARRIER WATER COOLER CARRIER -WCBL WATER COOLER BI-LEVEL CARRIER* -10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS) -60 VALVE PLATE FOR ATTACHING TO UPRIGHT X -BB BACK-TO-BACK CARRIER -10 STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS) -60 VALVE PLATE FOR ATTACHING TO UPRIGHT H _____________ J _____________ RIM HEIGHT________ BASED ON "B" DIM SHOWN SEPARATE SUBMITTAL FOR THIS OPTION AVAILABLE 59 DATE OF LAST CHANGE: 2/28/2014 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. NOTES DATE OF LAST CHANGE: 4/23/15 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES 60 SPECIFICATION: URINAL CARRIER JOSAM 17560-UR SERIES FLOOR-MOUNTED, SINGLE URINAL CARRIER WITH HANGER & BEARING PLATE, ADJUSTABLE SUPPORTING RODS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM. FLOOR-MOUNT BEARING PLATE SERIES REUSABLE ALIGNMENT TOOL AVAILABLE JOSAM 17560-WC SERIES FLOOR-MOUNTED, SINGLE WATER COOLER CARRIER WITH HANGER & BEARING PLATE, ADJUSTABLE SUPPORTING RODS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM. 17560-UR VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" 2 1/2" 1 MIN 4 MAX SPECIFICATION: SERIES REUSABLE ALIGNMENT TOOL AVAILABLE E H C HANGER FURNISHED WITH FIXTURE FINISHED WALL HANGER FURNISHED WITH FIXTURE MANUFACTURER _______________ MANUFACTURER _______________ J H NUMBER _______________ NUMBER _______________ SIZE _______________ SIZE _______________ B B J NAME _______________ BEARING STUDS NOT ATTACHED TO FIXTURE NAME _______________ DIMENSIONS B _____________ DIMENSIONS C _____________ B _____________ BEARING STUDS NOT ATTACHED TO FIXTURE C _____________ E _____________ FINISHED FLOOR 17560-WC VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" 2 1/2" 1 MIN 4 MAX C FINISHED WALL WATER COOLER CARRIER FLOOR-MOUNT BEARING PLATE FINISHED FLOOR H _____________ J _____________ H _____________ J _____________ RIM HEIGHT________ BASED ON "A" DIM SHOWN RIM HEIGHT________ BASED ON "A" DIM SHOWN 3" 3" 4 1/2" Fixture Carriers RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS. X -UR -10 X -WC URINAL CARRIER HARDWARE FOR WALLS OVER 4", SPECIFY WALL THICKNESS DATE OF LAST CHANGE: 3/25/2014 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. -10 NOTES 4 1/2" WATER COOLER CARRIER STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS) DATE OF LAST CHANGE: 11/10/2011 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES Fixture Carriers SPECIFICATION: JOSAM 17560-WCBL SERIES FLOOR-MOUNTED BI-LEVEL WATER COOLER CARRIER WITH HANGER AND BEARING PLATES, ADJUSTABLE SUPPORT RODS, STRUCTURAL UPRIGHTS, WELDED FEET, AND CHROME-PLATED TRIM. SERIES MANUFACTURER _____________ B ____________ NUMBER _____________ C ____________ SIZE _____________ C' ____________ NAME _____________ D ____________ E ____________ F ∆ 1" MIN. 4" MAX. 3 1/2" LAVATORY CARRIER SPECIFICATION: JOSAM 17590 SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER WITH HANGER PLATE AND ADJUSTABLE SUPPORTING RODS. WALL-MOUNT HANGER PLATE SERIES 17560-WCBL ____________ 17590 1/4 ______________ RIM HEIGHT BASED ON 'B' AND 'E' SHOWN FINISHED WALL C 7 MAX C' FINISHED WALL HANGER(S) FURNISHED WITH FIXTURE 3 5/8" MANUFACTURER _______________ NUMBER _______________ 42 1/4" B SIZE _______________ 4 NAME _______________ E D 21 1/2 F B VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" FINISHED FLOOR DIMENSIONS B _____________ RIM HEIGHT________ BASED ON "B" DIM SHOWN FINISHED FLOOR 3" 4 1/2" RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS USE SINGLE ALIGNMENT TOOL FOR PAIR OF UPRIGHTS FOR ALIGNING ALL 3 UPRIGHTS, 2 TOOLS ARE NECESSARY X -WCBL -10 BI-LEVEL WATER COOLER CARRIER STUDS FOR WALLS OVER 4" (SPECIFY) -DP -UR -10 DOUBLE PLATE CARRIER URINAL CARRIER STUDS FOR WALLS OVER 7" (SPECIFY WALL THICKNESS) SEPARATE SUBMITTAL FOR THIS OPTION AVAILABLE 61 DATE OF LAST CHANGE: 05/15/14 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. NOTES DATE OF LAST CHANGE: 5/04/15 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES 62 LAVATORY CARRIER SPECIFICATION: JOSAM 17590-DP SERIES WALL-MOUNTED, SINGLE LAVATORY CARRIER WITH HANGER PLATES AND ADJUSTABLE SUPPORTING RODS. WALL-MOUNT HANGER PLATE JOSAM 17590-UR SERIES WALL-MOUNTED, SINGLE URINAL CARRIER WITH HANGER PLATE AND ADJUSTABLE SUPPORTING RODS. 17590-DP SERIES 1/4 URINAL CARRIER SPECIFICATION: WALL-MOUNT HANGER PLATE 17590-UR SERIES 1/4 4 (STANDARD) 7 MAX 1/2 MIN FINISHED WALL HANGER(S) FURNISHED WITH FIXTURE MANUFACTURER _______________ FINISHED WALL HANGER(S) FURNISHED WITH FIXTURE MANUFACTURER _______________ NUMBER _______________ SIZE _______________ 4 NUMBER _______________ SIZE _______________ 4 NAME _______________ 21 1/2 NAME _______________ 21 1/2 DIMENSIONS B B _____________ VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" RIM HEIGHT________ BASED ON "B" DIM SHOWN Fixture Carriers X -DP -10 DATE OF LAST CHANGE: DOUBLE PLATE CARRIER STUDS FOR WALLS OVER 7" (SPECIFY WALL THICKNESS) 5/04/15 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA B _____________ RIM HEIGHT________ BASED ON "B" DIM SHOWN FINISHED FLOOR FINISHED FLOOR X DIMENSIONS B VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" NOTES -UR -10 DATE OF LAST CHANGE: URINAL CARRIER STUDS FOR WALLS OVER 7" (SPECIFY WALL THICKNESS) 5/04/15 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES Fixture Carriers URINAL CARRIER SPECIFICATION: JOSAM 17590-DP SERIES WALL-MOUNTED, SINGLE URINAL CARRIER WITH HANGER PLATES AND ADJUSTABLE SUPPORTING RODS. WALL-MOUNT HANGER PLATE 17590-UR-DP SERIES SINK CARRIER SPECIFICATION: JOSAM 17720 SERIES FLOOR-MOUNTED, SINGLE, HEAVY-DUTY SINK CARRIER WITH HANGER PLATE, ADJUSTABLE SUPPORTING RODS, ACID-RESISTING WHITE COATED ARMS, LEVELING AND SECURING SCREWS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM. FLOOR-MOUNT HEAVY-DUTY SERIES 17720 VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHOR BY OTHERS. 1 MIN 4 MAX 1/4 3 1/2" C 4 (STANDARD) 1/2 MIN MANUFACTURER _______________ FINISHED WALL HANGER(S) FURNISHED WITH FIXTURE MANUFACTURER _______________ 1 1/2" NUMBER _______________ NAME _______________ 21 1/2 A _____________ B _____________ A B _____________ VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" DIMENSIONS C+4 OR C-4 B DIMENSIONS B SIZE _______________ NAME _______________ SIZE _______________ 4 NUMBER _______________ RIM HEIGHT________ FINISHED WALL BASED ON "B" DIM SHOWN C _____________ RIM HEIGHT________ BASED ON "A&B" DIM SHOWN FINISHED FLOOR 3" 4 1/2" X X -DP -UR -10 63 DATE OF LAST CHANGE: DOUBLE PLATE CARRIER URINAL CARRIER STUDS FOR WALLS OVER 7" (SPECIFY WALL THICKNESS) 5/04/15 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES -VP -10 -66 FINISHED FLOOR VANDAL-PROOF TRIM STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS) SPLIT HEADER FOR STAINLESS STEEL ARMS (SEPERATE SUBMITTAL AVAILABLE DATE OF LAST CHANGE: 4/23/15 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES 64 SINK CARRIER SPECIFICATION: JOSAM 17720-66 SERIES FLOOR-MOUNTED, SINGLE, HEAVY-DUTY SINK CARRIER WITH HANGER PLATE, ADJUSTABLE SUPPORTING RODS, BEARING STUDS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM. FLOOR-MOUNT HEAVY-DUTY SERIES SINK CARRIER SPECIFICATION: JOSAM 17730 SERIES FLOOR-MOUNTED, SINGLE, HEAVY-DUTY SINK CARRIER WITH SUPPORT PLATES, ADJUSTABLE COUPLING WITH 4" PIPING CONNECTION, MOUNTING STUDS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM. 17720-66 FLOOR-MOUNT HEAVY-DUTY 17730 SERIES VARIABLE - DEPENDS ON FIXTURE EXCEPT WHEN STANDARD PLATE IS FURNISHED C = 18-1/4" NOTES 1. RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHOR BY OTHERS. 2. 3 1/2" DIMENSIONS MARKED VARY DEPENDING ON MOUNTED FIXTURE. RECOMMEND FEET BE SECURED TO FLOOR WITH 1/2" BOLTS & ANCHORS BY OTHERS. 1" MIN 4" MAX C 19" C D MANUFACTURER _______________ 5/8"-11 THREADED OR 1/2" THRU HOLE NUMBER _______________ C+4 OR C-4 NUMBER _______________ NAME _______________ 4 1/8" B _____________ C _____________ FINISHED WALL 42 1/4" B Fixture Carriers 4/23/15 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA C _____________ D_____________ E_____________ NOTES RIM HEIGHT________ FINISHED WALL FINISHED FLOOR VANDAL-PROOF TRIM STUDS FOR WALLS OVER 4" (SPECIFY WALL THICKNESS) SPLIT HEADER FOR STAINLESS STEEL ARMS (SEPERATE SUBMITTAL AVAILABLE DATE OF LAST CHANGE: B _____________ BASED ON "B" DIM SHOWN 4 1/2" -VP -10 -66 NAME _______________ 4" THREADED OUTLET CONNECTION RIM HEIGHT________ 3" 4 1/2" SIZE _______________ REVERSE THESE TWO PLATES FOR BLOWOUT FIXTURES WITH THREE BOLT MOUNT E H _____________ X MANUFACTURER _______________ SIZE _______________ H DIMENSIONS B 3 3/8" 1 1/2" MIN 6 1/8" MAX -VP -11 -60 FINISHED FLOOR BASED ON "B" DIM SHOWN 3" VANDAL-PROOF TRIM CAST IRON ADJUSTABLE EXTENSION (SPECIFY 6", 9" OR 12" ON ORDER) VALVE PLATE FOR ATTACHING TO UPRIGHT DATE OF LAST CHANGE: 4/23/15 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES Fixture Carriers SINK CARRIER SPECIFICATION: JOSAM 17735 SERIES FLOOR-MOUNTED, SINGLE, HEAVY-DUTY SINK CARRIER WITH SUPPORT PLATES, ADJUSTABLE COUPLING WITH 4" X 2" WASTE FITTING, MOUNTING STUDS, STRUCTURAL UPRIGHTS, WELDED FEET AND CHROME PLATED TRIM. FLOOR-MOUNT HEAVY-DUTY 17735 SERIES -45 (OPTION) -46 (OPTION) NOTES 7 5/8" 1. 4" 2. DIMENSIONS MARKED VARY DEPENDING ON MOUNTED FIXTURE. RECOMMEND FEET BE SECURED TO FLOOR WITH 1/2" BOLTS & ANCHORS BY OTHERS. 19" 3 3/8" C=15 3/4" 7/8" MIN 5 3/8" MAX D 5/8"-11 THREADED OR 1/2" THRU HOLE MANUFACTURER _______________ CUT EXTENSION AS NEEDED E NUMBER _______________ SIZE _______________ REVERSE THESE TWO PLATES FOR BLOWOUT FIXTURES WITH THREE BOLT MOUNT * 42 1/4" B NAME _______________ B _____________ C _____________ 4" THREADED OUTLET CONNECTION D_____________ E/G___________ RIM HEIGHT________ BASED ON "B" DIM SHOWN FINISHED WALL 4 1/2" *G FINISHED FLOOR 3" FOR BLOWOUT CONFIGURATION -4 -10 -45 -46 VANDAL-PROOF TRIM STUDS FOR WALLS OVER 5-3/8" (SPEC. WALL THICKNESS) THREADED HIGH LEFT-HAND AUXILIARY VENT THREADED HIGH RIGHT-HAND AUXILIARY VENT NOTE: OTHER FITTINGS AVAILABLE UPON REQUEST. CONTACT YOUR JOSAM REPRESENTATIVE 65 DATE OF LAST CHANGE: 4/23/15 DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES AND CHANGE WITHOUT NOTICE. WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA. JOSAM COMPANY MICHIGAN CITY, INDIANA NOTES