AXIALFANS AND ROOF FANS
Transcription
AXIAL FANS HEP HEPT HPX ROOF FANS HT AXIALFANS AND ROOF FANS According EU Regulation CVT CHT OUR COMMITMENT TO THE ENVIRONMENT Sodeca has begun a new stage of study and design of new trends in ventilation which will help to preserve the environment and to make the energy saving which so much concerns today’s society. SODECA has concentrated its activity on the production of industrial fans, ventilation systems and extractors for the removal of smoke in case of fire since 1983, when it was founded. SODECA’s fans and extractors are present in all European countries and in many parts of the world, thanks to the quality of the product and the methods of research and development used. Our quality procedures used and certified by BUREAU VERITAS, in accordance with ISO 9001:2008, are another of the reasons which make SODECA one of the best and most renowned fan manufacturers in Europe. Without a doubt, the most important factor to achieve our objectives is the human factor, the great professionals who work at your service, offering not only ventilation equipment but also solutions to any ventilation need required by our customers. We offer you the possibility of visiting our facilities in Sant Quirze de Besora, with over 16,000 square metres of built area, where you will be able to see our fan manufacture with perfect clarity and with the highest standards of quality, complying with the ISO and AMCA standards. This catalogue is only a small part of our possibilities. Do not hesitate to contact us. We will put all our experience and our human resources at your disposal. In order to obtain an improvement in the energetic consumption, SODECA has adjusted the impellers in the maximum efficiency working area. For this reason there might be changes in the curves of this catalogue compared to previous editions. Installations headquarters of SODECA s.a., at Sant Quirze de Besora and manufacturing plant in Santiago de Chile. AXIAL FANS AND ROOF FANS Sodeca has specialised since its inception in the design and manufacture of fans and accessories for industrial applications. The union of the experience acquired over decades of work with fans together with the technology supplied by engineers in different departments has made it possible for Sodeca to become one of the largest manufacturers of industrial ventilation in the world. The industrial applications require a great capacity for adaptation to the specifications of each project and flexibility in manufacture, so as to fulfil the real needs of each client. In order to fulfil this objective, Sodeca has a line of Standard products and a line of products with special manufacture, for the construction of fans adapted to the demands of our clients. For years constant investments have been made in the development of internal processes and applications to achieve the manufacture and supply of special industrial fans, with an extremely limited design and manufacturing period. Teamwork of our engineering department, together with universities and technology centres as well as close collaboration between the design departments of our external collaborators makes it possible to achieve innovative solutions of industrial ventilation in a short period of time. Throughout our history, we have developed all kinds of technology in fans for industrial applications which are currently used all over the world. It is our objective to continue to invest in this sector so as to continue to be one of the most esteemed manufacturers of industrial fans in the world. AXIAL FANS HEP HEPT 8 Wall-mounted axial fans, with IP-65 motor 8 Long-cased axial fans, with IP-65 motor HRE HCRE HCD HC 14 Wall-mounted axial fans with IP-55 motor HCH HFT Small-diameter wall-mounted axial fans 20 HCT Robust wall-mounted axial and long-cased fans Low noise wall-mounted axial fans with sheet steel impeller and external rotor motors 22 CJHCH 22 Circular axial fans with external rotor motor 38 HTM Cased high-pressure axial fans 96 VAM 103 57 Large long cased axial fans with external motor 57 HPX/SEC Long cased axial fans with external motor 94 Ventilators specially designed for operation in ceramic and wooden driers Large long cased axial fans with direct drive motor HBA Axial fans mobile long cased 4 41 HPX HCH/SEC HGTX HGT HTP Axial ventilation units with soundproofed box 27 99 HGI VAC Axial fans with galvanised frame and IP-65 motor and for ducts with IP-65 motor Forked tubular axial fans 105 Large-diameter axial fan Fans for extreme conditions in ovens and driers 101 KITS SOBREPRESIÓN 107 108 ROOF FANS HT Axial roof fans with flat base HTTI 112 Axial roof fans with sloping base depending on the roof slope 116 CHRE CVT 400ºC/2h centrifugal roof fans with vertical outlet air, hood in aluminium HTTAL 121 119 CTD Centrifugal roof fans with low noise level 126 Centrifugal roof fans for inlet of chimneys in houses 400ºC/2h centrifugal roof fans with horizontal outlet air, hood in aluminium 121 CA-ROOF 129 Centrifugal roof fans for inlet of chimneys in houses 131 RCH RCH-400X800 VM HTSOLAR TIRACAMINO Mixed axial roof fans (static + dynamic) with adjustable base for roof slopes from 0 to 30% CHT Sustainable roof fans powered by solar energy without electrical installation and without electricity consumption Fans to extract smoke in chimneys and barbecues 133 134 Fan and chimney top for hybrid extraction in community housing 136 5 AXIAL AND ROOF FANS CENTRIFUGAL FANS AND IN-LINE EXTRACTORS FANS FOR SMOKE EXTRACTION ATEX FANS FOR EXPLOSIVE ATMOSPHERES AND OTHER APPLICATIONS NEW SERIES - NEW PROD UCTS NEW CATALOGUES NEW BUSINESS OPPORTU NITIES LOW-PRESSURE CENTRIFUGAL FANS AIR CURTAINS FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS HEAT RECOVERY SYSTEMS AND FILTRATION UNITS Ask us for information Crta. de Berga, km 0,7 E-08580 St. Quirze de Besora BARCELONA (Spain) Tel. +34 93 852 91 11 Fax.+34 93 852 90 42 comercial@sodeca.com Export sales: ventilation@sodeca.com www.sodeca.com VENTILATION SYSTEM FOR HOUSES FULFILMENT OF STANDARDS SODECA's fans and extractors comply with the following standards: QUALITY ISO 9001:2008 Sistemas de gestión de la calidad. Requisitos. Quality management systems -- Requirements TESTS ISO 5801 Ventiladores industriales. Industrial fans -- Performance testing using standardized airways Industrial fans -- Performance testing using standardized airways AMCA 210-99 UNE 100212:1990 ISO 13350 ISO 13348 Ventiladores industriales. Métodos de ensayos de ventiladores y su representación de ensayos. Laboratory Methods of Testing Fans for Aerodynamic Performance Rating Ventiladores. Dispositivos e instalaciones para el ensayo de ventiladores. Ventiladores industriales. Ensayos de comportamiento de ventiladores de chorro. Industrial fans -- Performance testing of jet fans Industrial fans -- Tolerances, methods of conversion and technical data presentation FANS FOR HIGH TEMPERATURES EN 12101-3:2002 Sistemas de control de humos y calor. Parte 3: Especificaciones para aireadores extractores de humos y calor mecánicos. Smoke and heat control systems - Part 3: Specification for powered smoke and heat exhaust ventilators ACOUSTICS ISO 3744 Acústica. Determinación de los niveles de potencia acústica de fuentes de ruido a partir de la presión acústica. Método de ingeniería para condiciones de campo libre sobre un plano reflectante. Acoustics -- Determination of sound power levels of noise sources using sound pressure -- Engineering method in an essentially free field over a reflecting plane BALANCE AND VIBRATIONS ISO 1940-1 Vibraciones mecánicas. Calidad de equilibrado Mechanical vibration -- Balance quality requirements for rotors in a constant (rigid) state -- Part 1: Specification and verification of balance tolerances ISO 10816-1 Vibraciones mecánicas. Evaluación de las vibraciones de máquinas Mechanical vibration -- Evaluation of machine vibration by measurements on non-rotating parts -- Part 1: General guidelines ISO 14694 Ventiladores industriales. Especificaciones para equilibrado y niveles de vibración Industrial fans -- Specifications for balance quality and vibration levels SAFETY (Declaration of EC Compliance) EN ISO 12100-1 EN ISO 12100-2 EN 60204-1 Seguridad de las máquinas. Conceptos básicos, principios generales para el diseño. Parte 1: Terminología básica, metodología. Safety of machinery -- Basic concepts, general principles for design -- Part 1: Basic terminology, methodology Seguridad de las máquinas. Conceptos básicos, principios generales para el diseño. Parte 2: Principios técnicos. Safety of machinery -- Basic concepts, general principles for design -- Part 2: Technical principles Seguridad de las máquinas. Equipo eléctrico de las máquinas. Parte 1: Requisitos generales. Safety of machinery - Electrical equipment of machines - Part 1: General requirements EN 294 Seguridad de máquinas. Distancias de seguridad para impedir que se alcancen zonas peligrosas con los miembros superiores Safety of machinery; safety distances to prevent danger zones from being reached by the upper limbs ISO 13857 UNE 100250 ISO 12499 Seguridad de máquinas. Distancias de seguridad para impedir que se alcancen zonas peligrosas con los miembros superiores e inferiores. Safety of machinery -- Safety distances to prevent danger zones being reached by upper and lower limbs Ventiladores industriales. Seguridad mecánica de los ventiladores (equivalente ISO 12499) Ventiladores industriales. Seguridad mécanica en los ventiladores Industrial fans -- Mechanical safety of fans -- Guarding DIRECTIVES Directiva 2006/42/CE Directiva de máquinas Machinery Directive Directiva 2006/95/CE Directiva 2004/108/CE Directiva 89/106/CE Directiva 2009/125/CE Directiva de baja tensión Low Voltage Directive Directiva compatibilidad electromagnética EMC Directive Directiva productos de construcción Construction Products Directive (CPD) Directiva de requisitos de diseño ecológico para productos que utilizan energía. Ecodesign Requirements for Energy-related Products Directive ATEX EXECUTIONS Directiva ATEX 94/9/CE Aparatos y sistemas de protección para uso en atmósferas potencialmente explosivas Equipment and protective systems intended for use in potentially explosive atmospheres EN 14986 EN 13463-1 EN 1127-1 Diseño de ventiladores para trabajar en atmósferas potencialmente explosivas. Design of fans working in potentially explosive atmospheres Equipos no eléctricos destinados a atmósferas potencialmente explosivas. Parte 1: Requisitos y metodología básica. Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements Atmósferas explosivas. Prevención y protección contra la explosión. Parte 1: Conceptos básicos y metodología. Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology HEP HEPT HEP HEPT HEP: Wall-mounted axial fans, with IP-65 motor HEPT: Long-cased axial fans, with IP-65 motor Wall-mounted axial (HEP) and long-cased fans (HEPT), with fibreglass-reinforced plastic impeller. Fan: • Airflow direction from motor to impeller • Impeller in polyamide 6 reinforced with fibre glass • HEP: Sheet steel base plate. • HEP: Protection guard, meets UNE 100250 standard • HEPT: Sheet steel tubular casing. • HEPT: Outside connecting box, IP-65 protection HEP Motor: • Class F motors with ball bearings, IP-65 protection • Single-phase 220-240V.-50Hz. and three-phase 220-240/380-415V.-50Hz. • Working temperature: -25ºC +60ºC, 4-6-8 poles motors and -25ºC +45ºC, 2 pole motors Finish: • Anticorrosive finish in polyester resin, polymerised at 190ºC, after alkaline degreasing and phosphate-free pre-treatment. On request: • Motor, impeller and guard unit (version F) • Motor-impeller unit (version G) • Airflow direction from impeller to motor • Special windings for different voltages HEPT Order code HEP HEP: Wall-mounted axial fans, with IP-65 motor HEPT: Long-cased axial fans, with IP-65 motor 45 Impeller diameter in cm. 4T/HIF Number of motor poles 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz T=Three-phase Air circulation M=Single-phase I=Impeller Motor->Impeller H=High airflow L=Low airflow A=Airflow-in Impeller->Motor Execution of the fan Execution standard F=Motor impeller unit guard G=Motor impeller unit Technical characteristics Model HEP-25-2T/H HEP-25-2M/H HEP-25-4T/H HEP-25-4M/H HEP-31-2T/H HEP-31-2M/H HEP-31-4T/H HEP-31-4M/H HEP-31-4T/L HEP-31-4M/L HEP-35-2T/H HEP-35-2M/H 8 Speed - - - - HEPT-31-2T/H HEPT-31-2M/H HEPT-31-4T/H HEPT-31-4M/H - - HEPT-35-2T/H HEPT-35-2M/H (r/min) 2780 2750 1450 1440 2640 2640 1410 1410 1430 1420 2790 2675 Maximum admissible current (A) 220-240V 380-415V 1.30 1.95 0.69 0.65 1.54 2.30 0.69 0.75 0.69 0.70 2.16 2.80 0.75 - 0.40 - 0.89 - 0.40 - 0.40 - 1.25 - Absorbed power at free airflow (W) 265 345 85 95 400 410 115 130 100 110 550 560 Maximum Sound Approx. weight airflow pressure level (Kg) 3 (m /h) dB(A) HEP HEPT 2300 2300 1250 1250 4000 4000 2400 2400 1950 1950 6020 6020 64 64 52 52 74 74 55 55 54 54 76 76 5.3 5.3 4.5 4.5 7.0 7.0 5.7 5.7 5.1 5.1 8.8 8.8 7.4 7.4 6.2 6.2 9.4 9.4 HEP HEPT Technical characteristics Model HEP-35-4T/H HEP-35-4M/H HEP-35-4T/L HEP-35-4M/L HEP-40-4T/H HEP-40-4M/H HEP-40-4T/L HEP-40-4M/L HEP-40-6T/H HEP-40-6M/H HEP-45-4T/H HEP-45-4M/H HEP-45-4T/L HEP-45-4M/L HEP-45-6T/H HEP-45-6M/H HEP-50-4T/H HEP-50-4M/H HEP-50-4T/L HEP-50-4M/L HEP-50-6T/H HEP-50-6M/H HEP-56-4T/H HEP-56-4M/H HEP-56-4T/L HEP-56-4M/L HEP-56-6T/H HEP-56-6M/H HEP-63-4T/H HEP-63-4T/L HEP-63-4M/L HEP-63-6T/H HEP-63-6M/H HEP-63-6T/L HEP-63-6M/L HEP-63-8T/H HEP-63-8M/H Speed (r/min) 1340 1340 1410 1410 1420 1400 1450 1420 960 960 1400 1400 1440 1360 955 955 1420 1380 1400 1370 950 950 1350 1350 1400 1350 915 915 1415 1375 1375 905 905 945 945 700 700 HEPT-35-4T/H HEPT-35-4M/H - - HEPT-40-4T/H HEPT-40-4M/H - - HEPT-40-6T/H HEPT-40-6M/H HEPT-45-4T/H HEPT-45-4M/H - - HEPT-45-6T/H HEPT-45-6M/H HEPT-50-4T/H HEPT-50-4M/H - - HEPT-50-6T/H HEPT-50-6M/H HEPT-56-4T/H HEPT-56-4M/H - - HEPT-56-6T/H HEPT-56-6M/H HEPT-63-4T/H - - HEPT-63-6T/H HEPT-63-6M/H - - - - Maximum admissible current (A) 220-240V 380-415V 0.74 0.43 0.98 - 0.69 0.40 0.75 - 2.10 1.20 1.85 - 2.10 1.20 1.55 - 1.12 0.65 1.06 - 2.11 1.22 2.35 - 2.10 1.20 1.85 - 1.42 0.82 1.40 - 3.10 1.80 3.35 - 2.15 1.25 2.30 - 1.38 0.80 1.38 - 3.63 2.10 5.26 - 3.20 1.85 3.40 - 1.73 1.00 2.12 - 6.92 4.00 5.01 2.90 5.40 - 2.06 1.19 2.70 - 1.62 0.94 1.80 - 1.90 1.10 1.89 - Absorbed power at free airflow (W) 155 160 110 120 245 355 185 260 155 185 475 490 300 315 215 225 740 710 390 430 205 215 870 895 710 755 325 450 1400 1275 1160 405 540 305 330 320 320 Maximum Sound Approx. weight airflow pressure level (Kg) 3 (m /h) dB(A) HEP HEPT 3500 58 7.1 7.6 3500 58 7.1 7.6 2650 56 6.5 2650 56 6.5 5200 61 10.6 13.5 5200 61 10.6 13.5 4000 60 10.6 4000 60 10.6 3500 54 10.2 13.5 3500 54 10.2 13.5 7300 66 12.5 15.5 7300 66 12.5 15.5 5810 64 11.0 5810 64 11.0 4900 56 11.4 15.5 4900 56 11.4 15.5 10150 69 15.0 18.0 10150 69 15.0 18.0 7300 67 13.0 7300 67 13.0 6150 59 13.2 18.0 6150 59 13.2 18.0 12800 72 21.0 28.0 12800 72 21.0 28.0 10900 70 19.0 10900 70 19.0 8250 62 17.0 28.0 8250 62 17.0 28.0 18700 82 25.8 33.5 16500 75 23.0 16500 75 23.0 12050 65 20.2 33.5 12050 65 20.2 33.5 9450 63 19.4 9450 63 19.4 8250 57 19.2 8250 57 19.2 - Erp. BEP (best efficiency point) characteristics MC EC VSD SR Model 25-4T/H 25-4M/H 31-2T/H 31-2M/H 31-4T/H 31-4M/H 31-4T/L 31-4M/L 35-2T/H 35-2M/H 35-4T/H 35-4M/H 35-4T/L 35-4M/L 40-4T/H MC - - A A - - - - A A A A - - A ηe[%] Efficiency N Degree of efficiency [kW] Electrical power 3 [m /h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship EC - - S S - - - - S S S S - - S VSD - - NO NO - - - - NO NO NO NO - - NO SR - - 1.00 1.00 - - - - 1.00 1.00 1.00 1.00 - - 1.00 ηe[%] - - 30.3% 28.9% - - - - 35.3% 34.6% 28.3% 26.1% - - 26.8% N - - 39.2 37.6 - - - - 42.9 42.2 39.9 37.4 - - 37.5 (kW) 0.083 0.096 0.397 0.417 0.109 0.122 0.096 0.109 0.620 0.632 0.145 0.158 0.117 0.124 0.202 (m3/h) 986 990 2782 2793 1304 1290 1141 1161 4356 4396 2167 2191 1874 1919 2135 (mmH2O) 2.73 2.72 15.89 15.84 5.05 5.10 4.37 4.30 18.46 18.28 6.95 6.89 4.95 4.97 9.28 (RPM) 1471 1466 2827 2854 1449 1461 1460 1452 2880 2851 1418 1430 1443 1451 1470 9 HEP HEPT Erp. BEP (best efficiency point) characteristics Model 40-4T/L 45-4T/H 45-4M/H 45-4T/L 45-4M/L 50-4T/H 50-4M/H 50-4T/L 50-4M/L 50-6T/H 50-6M/H 56-4T/H 56-4M/H 56-4T/L 56-4M/L 56-6T/H 63-4T/H 63-4T/L 63-4M/L 63-6T/H 63-6T/L 63-6M/L MC EC A A A A A A A A A A A A A A A A A A A A A A VSD S S S S S S S S S S S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO SR 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 ηe[%] 26.3% 33.1% 29.3% 33.0% 30.9% 31.1% 30.1% 32.9% 29.0% 28.6% 26.8% 31.3% 30.8% 30.3% 29.0% 27.7% 32.0% 36.0% 34.8% 28.5% 29.7% 28.4% N (kW) (m3/h) 37.5 41.8 37.6 42.7 40.4 38.7 37.6 41.8 37.6 39.5 37.5 38.3 37.7 37.7 36.2 37.5 37.7 41.9 40.8 37.6 39.3 37.9 0.172 0.418 0.480 0.292 0.314 0.626 0.645 0.387 0.438 0.187 0.201 0.798 0.817 0.697 0.730 0.283 1.253 1.170 1.138 0.373 0.300 0.314 2248 4235 4541 3719 3805 5994 5967 4894 4853 3484 3601 7546 7780 7344 7358 4469 10152 10263 10512 6577 5326 5389 (mmH2O) 7.41 11.98 11.37 9.53 9.36 11.92 11.96 9.54 9.61 5.64 5.50 12.16 11.88 10.57 10.55 6.46 14.52 15.10 13.85 5.95 6.13 6.07 (RPM) 1476 1447 1450 1467 1439 1458 1446 1446 1434 977 979 1432 1442 1448 1432 964 1462 1432 1445 957 973 969 Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at an equivalent distance of twice the fan’s span plus the impeller’s diameter, with a minimum of 1.5 m. Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. Model 25-2/H 25-4/H 31-2/H 31-4/H 31-4/L 35-2/H 35-4/H 35-4/L 40-4/H 40-4/L 40-6/H 45-4/H 45-4/L 10 63 39 27 49 30 29 51 33 31 36 35 29 43 41 125 250500 1000200040008000 52 64 68 70 70 66 58 40 52 56 58 58 54 46 62 74 78 80 80 76 68 43 55 59 61 61 57 49 42 54 58 60 60 56 48 64 76 80 82 82 78 70 46 58 62 64 64 60 52 44 56 60 62 62 58 50 49 61 65 67 67 63 55 48 60 64 66 66 62 54 42 54 58 60 60 56 48 57 69 72 74 75 71 62 55 67 70 72 73 69 60 Model 45-6/H 50-4/H 50-4/L 50-6/H 56-4/H 56-4/L 56-6/H 63-4/H 63-4/L 63-6/H 63-6/L 63-8/H 63 33 46 44 36 49 47 39 61 54 44 42 36 125 250500 1000200040008000 47 59 62 64 65 61 52 60 72 75 77 78 74 65 58 70 73 75 76 72 63 50 62 65 67 68 64 55 63 75 78 80 81 77 68 61 73 76 78 79 75 66 53 65 68 70 71 67 58 75 87 90 92 92 89 80 68 80 83 85 85 82 73 58 70 73 75 75 72 63 56 68 71 73 73 70 61 50 62 65 67 67 64 55 HEP HEPT Dimensions in mm HEP Standard version with connection box Model A Version on request without connection box E F D2T 4T6T8T 2T 4T 6T8T G H B C HEP-25 330 275 262 260 189 179 - - 213 203 - - 11 56 8.5 JK L 310 M.8 HEP-31..../H 400 336 310.5 308 190 180 - - 214 204 - - 11 75 10.5 380 M.8 HEP-31.../L 400 336 310.5 308 - 180 - - - 204 - - 11 75 10.5 380 M.8 HEP-35.../H 465 390 362.5 360 217 187 - - 241 211 - - 11 86 10.5 450 M.8 HEP-35.../L 465 390 362.5 360 - 187 - - - 211 - - 11 86 10.5 450 M.8 HEP-40.../H 532 452 412.5 410 - 206 186 - - 226 205 - 11 97.5 10.5 500 M.8 HEP-40.../L 532 452 412.5 410 - 206 - - - 226 - - 11 97.5 10.5 500 M.8 HEP-45.../H 596 504 462.5 460 - 214 199 - - 234 218 - 11 105 10.5 560 M.8 HEP-45.../L 596 504 462.5 460 - 214 - - - 234 - - 11 105 10.5 560 M.8 HEP-50.../H 665 562 516.5 514 - 255 235 - - 275 254 - 11 115 10.5 640 M.8 HEP-50.../L 665 562 516.5 514 - 240 - - - 260 - - 11 115 10.5 640 M.8 HEP-56.../H 710 630 563 560 - 287 247 - - 306 266 - 15 115 10.5 721 M.8 - HEP-56.../L 710 630 563 560 - 267 - - 286 - - 15 115 10.5 721 M.8 HEP-63.../H 800 710 638 635 - - 257 247 - 340 276 266 15 140 10.5 820 M.8 HEP-63.../L 800 710 638 635 - - 247 - 340 266 - 15 140 10.5 820 M.8 - HEPT Model A B HEPT-31 385 355 308 DEJ 200 10 Drills No. 8 HEPT-35 425 395 360 220 10 8 HEPT-40 490 450 410 220 12 8 HEPT-45 540 500 460 220 12 8 HEPT-50 600 560 514 230 12 12 HEPT-56 660 620 560 260 12 12 HEPT-63 730 690 635 350 12 12 11 HEP HEPT Characteristic curves Q = Airflow in m3/h, m3/s and cfm. 12 Pe= Static pressure in mmH2O, Pa and inwg. HEP HEPT Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. Accessories See accessories section. INT RM AR RFT/ RFM PANELS PL P PT/H RI RT BTUB BAC PS S SI 13 HC HC Wall-mounted axial fans, with IP-55 motor Wall-mounted axial fans with fibreglass-reinforced plastic impeller Fan: • Sheet steel base plate. • Impeller in polyamide 6 reinforced with fibre glass • Protection guard, meets UNE 100250 standard • Models 71, 80, 90 and 100, the protective grille is supplied as an accessory • Airflow direction from motor to impeller Motor: • Single-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors, with ball bearings and IP55 protection, except single-phase versions from size 45 to size 63, IP54 protection, one- or two-speed depending on the model • Single-phase 230V -50Hz. and three-phase 230/400V.50Hz. (up to 5.5CV.) and 400/690V.-50Hz. (power over 5.5CV.) • Working temperature: -25ºC+ 60ºC HC HC 71, 80, 90,100 Finish: • Anticorrosive finish in polyester resin, polymerised at 190ºC, after alkaline degreasing and phosphate-free pre-treatment. On request: • Motor, impeller and guard unit (version F) • Motor-impeller unit, version G. • Airflow direction from impeller to motor. • Special windings for different voltages. Order code HC Wall-mounted axial fans, with IP-55 motor 25 Impeller diameter in cm. 2T/HIF Number of motor poles 2=2900 r/min. 50 Hz 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz 12=500 r/min. 50 Hz T=Three-phase Air circulation M=Single-phase I=Impeller Motor->Impeller H=High airflow L=Low airflow A=Airflow-in Impeller->Motor Execution of the fan Execution standard F=Motor impeller unit guard G=Motor impeller unit Technical characteristics Model HC-25-2T/H HC-25-2M/H HC-25-4T/H HC-25-4M/H HC-31-2T/H HC-31-2M/H HC-31-4T/H 14 Speed (r/min) 2730 2770 1320 1380 2750 2700 1320 Maximum admissible current (A) 230V 400V 690V 0.74 0.43 0.98 0.96 0.56 0.65 1.21 0.70 1.85 0.96 0.56 Installed power (kW) 0.12 0.12 0.10 0.10 0.18 0.18 0.10 Maximum airflow (m3/h) 2200 2200 1300 1300 3650 3600 2400 Sound Approx. weight pressure level (Kg) dB(A) 64 64 51 51 72 72 54 5 5 5 5 6 6 6 HC Technical characteristics Model HC-31-4M/H HC-31-4T/L HC-31-4M/L HC-35-2T/H HC-35-4T/H HC-35-4M/H HC-35-4T/L HC-35-4M/L HC-40-4T/H HC-40-4M/H HC-40-4T/L HC-40-4M/L HC-40-6T/H HC-40-6M/H HC-45-4T/H HC-45-4M/H HC-45-4T/L HC-45-4M/L HC-45-6T/H HC-45-6M/H HC-50-4T/H HC-50-4M/H HC-50-4T/L HC-50-4M/L HC-50-6T/H HC-50-6M/H HC-56-4T/H HC-56-4/8T/H HC-56-4T/L HC-56-4M/L HC-56-6T/H HC-56-6M/H HC-63-4T/H HC-63-4/8T/H HC-63-4T/L HC-63-4M/L HC-63-6T/H HC-63-6M/H HC-71-4T/H HC-71-4/8T/H HC-71-6T/H HC-71-6/12T/H HC-71-6M/H HC-80-4T/H HC-80-4/8T/H HC-80-4T/L HC-80-6T/H HC-80-6/12T/H HC-80-6T/L HC-90-4T/H HC-90-4/8T/H HC-90-4T/L HC-90-6T/H HC-90-6/12T/H HC-90-6T/L HC-90-8T/H HC-100-4T/H HC-100-4/8T/H HC-100-4T/L HC-100-6T/H HC-100-6/12T/H HC-100-6T/L HC-100-8T/H Speed (r/min) Maximum admissible current (A) 230V 400V 690V 1380 1.03 1320 0.65 0.38 1380 0.65 2710 1.92 1.11 1320 0.96 0.56 1380 1.03 1320 0.96 0.56 1380 0.65 1350 1.66 0.96 1370 2.00 1320 0.96 0.56 1380 1.03 900 1.51 0.87 970 1.30 1370 2.02 1.17 1400 2.76 1350 1.66 0.96 1370 2.00 900 1.51 0.87 950 1.50 1380 2.92 1.69 1350 5.02 1350 1.66 0.96 1370 2.00 900 2.24 1.30 900 2.69 1400 4.03 2.32 1440 / 710 2.9 / 1.3 1380 2.92 1.69 1380 4.60 900 2.24 1.30 900 2.69 1400 4.03 2.32 1440 / 710 2.9 / 1.3 1410 3.10 1.79 1430 4.78 900 2.24 1.30 890 3.00 1430 5.96 3.44 1420 / 700 3.5 / 1.5 945 3.90 2.20 935 / 435 2.2 / 0.87 900 4.97 1445 10.96 6.33 1430 / 710 6.5 / 2.3 1430 5.96 3.44 945 3.90 2.20 935 / 435 2.2 / 0.87 900 2.99 1.73 1440 14.10 8.12 1430 / 710 8.2 / 2.9 1445 10.96 6.33 955 6.42 3.71 970 / 470 4.6 / 1.9 945 4.88 2.82 695 3.53 2.04 1440 11.60 6.72 1450 / 720 11.8 / 3.8 1440 14.10 8.12 955 6.42 3.71 970 / 470 4.6 / 1.9 945 4.88 2.82 705 4.68 2.70 Installed power (kW) 0.10 0.08 0.10 0.37 0.10 0.10 0.10 0.10 0.25 0.25 0.10 0.10 0.25 0.25 0.37 0.37 0.25 0.25 0.25 0.25 0.55 0.55 0.25 0.25 0.37 0.37 1.10 1.10/0.25 0.55 0.55 0.37 0.37 1.10 1.10/0.25 0.75 0.55 0.37 0.37 1.50 1.50/0.37 0.75 0.75/0.15 0.75 3.00 3.0/0.60 1.50 0.75 0.75/0.15 0.55 4.00 4.00/0.80 3.00 1.50 1.50/0.25 1.10 0.55 5.50 5.50/1.10 4.00 1.50 1.50/0.25 1.10 0.75 Maximum airflow (m3/h) 2400 1800 1750 6050 3550 3550 2600 2600 5200 5200 4050 4050 3700 3700 7300 7300 5600 5600 5150 5150 10200 10200 7400 7400 6300 6300 13000 13000/6500 11050 11050 8300 8300 16450 16450/8225 14400 14400 12350 12350 22150 22200/11100 17300 17350/8675 15600 33000 33000/16500 25000 22000 22000/11000 19200 43700 43700/21850 33700 33300 33300/16650 26550 19800 54000 54000/27000 42750 37000 37000/18500 29000 26950 Sound Approx. weight pressure level (Kg) dB(A) 54 52 52 76 58 58 56 56 63 63 59 59 55 55 66 66 63 63 57 57 69 69 66 66 59 59 72 72/57 70 70 61 61 74 74/59 73 73 64 64 78 78/63 66 66/51 65 82 82/67 79 71 71/56 70 86 86/69 83 76 76/61 73 69 88 88/73 84 78 78/63 76 72 6 6 6 8 7 7 7 7 10 10 8 8 10 10 14 14 11 11 14 14 18 18 12 12 18 18 24 24 18 18 19 19 26 26 19 19 21 21 35 35 36 35 36 55 53 44 45 44 39 68 74 63 60 70 55 54 85 95 71 63 73 58 61 15 HC Erp. BEP (best efficiency point) characteristics MC EC VSD SR Model MC HC-25-4T/H HC-25-4M/H HC-31-2T/H HC-31-2M/H HC-31-4T/H HC-31-4M/H HC-31-4T/L HC-31-4M/L HC-35-2T/H HC-35-4T/H HC-35-4M/H HC-35-4T/L HC-35-4M/L HC-40-4T/H HC-40-4M/H HC-40-4T/L HC-40-4M/L HC-45-4T/H HC-45-4M/H HC-45-4T/L HC-45-4M/L HC-45-6T/H HC-45-6M/H HC-50-4T/H HC-50-4M/H HC-50-4T/L HC-50-4M/L HC-56-4T/H HC-56-4/8T/H HC-56-4T/L HC-56-4M/L HC-56-6T/H HC-56-6M/H HC-63-4T/H HC-63-4/8T/H HC-63-4T/L HC-63-4M/L HC-63-6T/H HC-63-6M/H HC-71-4T/H HC-71-4/8T/H HC-71-6T/H HC-71-6/12T/H HC-71-6M/H HC-80-4T/H HC-80-4/8T/H HC-80-4T/L HC-80-6T/H HC-80-6/12T/H HC-80-6T/L HC-90-4T/H HC-90-4/8T/H HC-90-4T/L HC-90-6T/H HC-90-6/12T/H HC-90-6T/L HC-90-8T/H HC-100-4T/H HC-100-4/8T/H HC-100-4T/L HC-100-6T/H HC-100-6/12T/H HC-100-6T/L HC-100-8T/H 16 - - A A - - - - A A A - - A A A A A A A A A A A A A A A A A A A A C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C ηe[%] Efficiency N Degree of efficiency [kW] Electrical power 3 [m /h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship EC - - S S - - - - S S S - - S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S VSD - - NO NO - - - - NO NO NO - - NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO SR - - 1.00 1.00 - - - - 1.00 1.00 1.00 - - 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 ηe[%] - - 28.7% 27.9% - - - - 35.6% 31.5% 26.3% - - 29.8% 28.0% 30.6% 26.7% 36.3% 31.4% 31.9% 28.1% 28.8% 26.8% 34.2% 29.7% 40.8% 37.2% 35.8% 31.9% 38.7% 38.1% 32.6% 28.7% 40.1% 32.4% 40.7% 33.3% 33.4% 31.7% 42.0% 37.6% 34.4% 30.7% 29.4% 48.4% 42.8% 50.1% 44.3% 39.8% 46.3% 49.2% 43.0% 45.7% 40.2% 37.1% 41.5% 39.2% 47.2% 42.8% 49.9% 50.5% 48.3% 49.3% 37.8% N - - 38.5 37.5 - - - - 43.4 43.1 37.5 - - 39.5 37.5 41.7 37.5 45.0 39.7 41.7 37.5 39.7 37.5 41.8 37.0 49.9 46.0 41.9 37.7 46.1 45.6 41.8 37.6 46.0 37.8 47.6 39.7 41.5 39.6 46.8 42.0 41.9 37.7 36.4 51.5 45.5 54.8 50.8 46.0 53.3 52.0 45.4 49.1 45.1 41.8 47.1 46.7 48.6 43.9 52.0 55.1 52.8 54.8 44.1 (kW) 0.099 0.102 0.284 0.296 0.110 0.116 0.099 0.104 0.584 0.144 0.172 0.115 0.123 0.290 0.311 0.174 0.199 0.423 0.490 0.283 0.322 0.190 0.205 0.611 0.708 0.360 0.395 1.066 1.205 0.661 0.673 0.353 0.402 1.164 1.429 0.806 0.986 0.521 0.554 1.793 2.034 0.667 0.798 0.772 3.247 3.680 1.814 0.935 1.041 0.802 3.650 4.191 2.923 1.640 1.778 1.301 0.667 5.992 6.592 4.634 1.905 1.992 1.342 1.023 (m3/h) 707 693 1781 1764 1392 1388 922 948 3352 2044 2028 1466 1502 3617 3713 2394 2375 4282 4333 3635 3728 2675 2819 5349 5551 4320 4120 8315 8515 7355 7501 5086 5247 9340 9621 8607 8333 7201 7578 13627 13456 9443 10137 10923 19996 20166 12760 12533 12670 10262 24299 24026 19552 15731 15887 14635 11772 28190 28757 23348 20265 20356 17161 16029 mmH2O 5.15 5.24 16.86 17.16 6.66 6.68 6.81 6.44 22.79 8.13 8.19 6.79 6.63 8.79 8.63 8.17 8.23 13.18 13.05 9.12 8.93 7.51 7.17 14.34 13.90 12.50 13.08 16.85 16.59 12.76 12.57 8.30 8.09 18.35 17.69 14.00 14.47 8.89 8.51 20.31 20.90 8.94 8.89 7.63 28.89 28.66 26.16 12.14 12.02 13.31 27.16 27.54 25.10 15.38 15.24 13.55 8.16 36.83 36.01 36.36 17.44 17.37 14.17 8.86 (RPM) 1407 1432 2743 2783 1397 1423 1389 1432 2703 1365 1387 1393 1419 1395 1406 1337 1369 1403 1418 1398 1403 935 953 1412 1418 1370 1381 1421 1454 1405 1422 941 929 1413 1445 1423 1385 913 903 1431 1421 963 953 929 1449 1433 1430 948 939 902 1452 1439 1454 961 974 949 707 1442 1453 1440 954 971 948 709 HC Dimensions in mm HC 25...63 HC 71...100 Model B C B C HC-25 330 275 A 262 260 236.5 11 D EG H JK 56 8.5 310 HC-71-4T/H 850 810 715 711 395 20 170 14.5 HC-31-2 400 336 310.5 308 264.5 11 65 10.5 380 HC-71-6T/H 850 810 715 711 395 20 170 14.5 HC-31-4 400 336 310.5 308 245.5 11 65 10.5 380 HC-80-4T/H 970 910 801 797 488 20 210 14.5 HC-35-2 465 390 362.5 360 275.5 11 76 10.5 450 HC-80-4T/L 970 910 801 797 458 20 210 14.5 HC-35-4 465 390 362.5 360 256.5 11 76 10.5 450 HC-80-6T/H 970 910 801 797 458 20 210 14.5 HC-40-4.../H 532 452 412.5 410 297.5 11 97.5 10.5 500 HC-80-6T/L 970 910 801 797 416 20 210 14.5 HC-40-4.../L 532 452 412.5 410 278.5 11 97.5 10.5 500 HC-90-4T/H 1170 1110 918 914 511 20 210 14.5 HC-40-6.../H 532 452 412.5 410 308.5 11 97.5 10.5 500 HC-90-4T/L 1170 1110 918 914 488 20 210 14.5 HC-45-4.../H 596 504 462.5 460 315.5 11 105 10.5 560 HC-90-6T/H 1170 1110 918 914 488 20 210 14.5 HC-45-4.../L 596 504 462.5 460 304.5 11 105 10.5 560 HC-90-6T/L 1170 1110 918 914 455 20 210 14.5 HC-45-6.../H 596 504 462.5 460 315.5 11 105 10.5 560 HC-90-8T/H 1170 1110 918 914 455 20 210 14.5 HC-50-4T/H 665 562 516.5 514 325.5 11 115 10.5 640 HC-100-4T/H 1170 1110 1003 999 548 20 220 14.5 HC-50-4M/H 665 562 516.5 514 351 11 115 10.5 640 HC-100-4T/L 1170 1110 1003 999 521 20 220 14.5 HC-50-4.../L 665 562 516.5 514 283.5 11 115 10.5 640 HC-100-6T/H 1170 1110 1003 999 498 20 220 14.5 HC-50-6.../H 665 562 516.5 514 351 11 115 10.5 640 HC-100-6T/L 1170 1110 1003 999 468 20 220 14.5 HC-56-4T/H 710 630 563 560 374 15 115 10.5 721 HC-100-8T/H 1170 1110 1003 999 498 20 220 14.5 HC-56-4T/L 710 630 563 560 325.5 15 115 10.5 721 HC-56-4M/L 710 630 563 560 351 15 115 10.5 721 HC-56-6.../H 710 630 563 560 351 15 115 10.5 721 HC-63-4T/H 800 710 638 635 399 15 140 10.5 820 HC-63-4.../L 800 710 638 635 376 15 140 10.5 820 HC-63-6.../H 800 710 638 635 376 15 140 10.5 820 Model A D EG H J Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at an equivalent distance of twice the fan’s span plus the impeller’s diameter, with a minimum of 1.5 m. Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. Model 25-2/H 25-4/H 31-2/H 31-4/H 31-4/L 35-2/H 35-4/H 35-4/L 40-4/H 40-4/L 40-6/H 45-4/H 45-4/L 45-6/H 50-4/H 50-4/L 50-6/H 56-4/H 56-6/H 56-8/H 56-4/L 63-4/H 63-6/H 63-8/H 63 38 25 46 28 26 50 32 30 28 29 20 33 36 24 36 39 26 39 28 24 43 43 33 28 125 250500 1000200040008000 48 65 65 73 69 62 53 35 52 52 60 56 49 40 56 73 73 81 77 70 61 38 55 55 63 59 52 43 36 53 53 61 57 50 41 60 77 77 85 81 74 65 42 59 59 67 63 56 47 40 57 57 65 61 54 45 45 57 65 70 70 66 59 45 55 59 66 66 62 55 37 49 57 62 62 58 51 50 63 70 75 76 71 64 51 61 66 72 73 69 62 41 54 61 66 67 62 55 53 66 73 78 79 74 67 54 64 69 75 76 72 65 43 56 63 68 69 64 57 56 69 76 81 82 77 70 45 58 65 70 71 66 59 41 54 61 66 67 62 55 58 68 73 79 80 76 69 60 73 80 85 86 81 74 50 63 70 75 76 71 64 45 58 65 70 71 66 59 Model 63-4/L 71-4/H 71-6T/H 71-6M/H 71-8/H 71-12/H 80-4/H 80-6/H 80-8/H 80-12/H 80-4/L 80-6/L 90-4/H 90-6/H 90-8/H 90-12/H 90-4/L 90-6/L 100-4/H 100-6/H 100-8/H 100-12/H 100-4/L 100-6/L 63 48 47 35 34 32 20 60 49 45 34 57 48 64 54 47 39 61 51 68 58 52 43 64 56 125 250500 1000200040008000 63 73 78 84 85 81 74 64 77 84 89 90 85 78 52 65 72 77 78 73 66 51 64 71 76 77 72 65 49 62 69 74 75 70 63 37 50 57 62 63 58 51 81 88 93 96 92 85 74 70 77 82 85 81 74 63 66 73 78 81 77 70 59 55 62 67 70 66 59 48 78 85 90 93 89 82 71 69 76 81 84 80 73 62 85 92 97 100 96 89 78 75 82 87 90 86 79 68 68 75 80 83 79 72 61 60 67 72 75 71 64 53 82 89 94 97 93 86 75 72 79 84 87 83 76 85 88 96 101 103 100 93 82 78 86 91 93 90 83 72 72 80 85 87 84 77 66 63 71 76 78 75 68 57 84 92 97 99 96 89 78 76 84 89 91 88 81 70 17 HC Characteristic curves Q = Airflow in m3/h, m3/s and cfm. 18 Pe= Static pressure in mmH2O, Pa and inwg. HC Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. Accessories See accessories section. INT RM C2V AR RFT/ RFM PANELS PL P R RI S SI 19 HCD HCD Small-diameter wall-mounted axial fans Wall-mounted axial fans with aluminium sheet impellers, shading ring motors and incorporated connection cable. Fan: • Sheet steel base plate. • Aluminium sheet impeller • Protection guard, meets UNE 100250 standard • Airflow direction from motor to impeller Motor: • Class B motors with dry friction bearings, IP44 protection, except model 40 supplied with class F motor, ball bearings, IP54 protection • Single-phase 230V.-50Hz. • Working temperature: -25ºC.+ 50ºC Finish: • Anticorrosive finish in polyester resin, polymerised at 190ºC, after alkaline degreasing and phosphate-free pre-treatment. On request: • Special windings for different voltages Order code HCD 20 Small-diameter wall-mounted axial fans 4M Impeller diameter in cm. Number of motor poles 4=1400 r/min. 50 Hz M=Single-phase Technical characteristics Model Speed (r/min) HCD-20-4M HCD-25-4M HCD-30-4M HCD-35-4M HCD-40-4M 1350 1340 1360 1365 1410 Maximum admissible current (A) 230V 0.21 0.25 0.51 0.80 1.00 Absorbed power at free airflow (W) 36 41 76 115 150 Maximum airflow (m3/h) 560 960 1350 1820 3100 Sound Approx. weight pressure level (Kg) dB(A) 38 43 48 53 57 1.15 1.60 2.15 6.20 7.20 Erp. BEP (best efficiency point) characteristics MC EC VSD SR Model HCD-20-4M HCD-25-4M HCD-30-4M HCD-35-4M HCD-40-4M 20 MC A A A A A ηe[%] Efficiency N Degree of efficiency [kW] Electrical power [m3/h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship EC VSD SR S S S S S - - - - NO - - - - 1.00 ηe[%] - - - - 25.9% N (kW) (m3/h) mmH2O - - - - 37.43 0.029 0.036 0.080 0.123 0.149 399 545 762 906 1845 1.80 2.78 4.79 7.30 7.70 (RPM) 1403 1386 1397 1384 1390 HCD Dimensions in mm Model A B HCD-20 266 222 211 104.5 C EF J 34 9 240 P HCD-25 330 275 262 105.5 56 10.5 290 HCD-30 400 336 311 153 75 10.5 348 HCD-35 465 390 363 166 86 10.5 410 HCD-40 532 452 413 276 97.5 10.5 460 Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. Accessories See accessories section. INT RM PL P RI SI 21 HRE HCRE HRE HCRE HRE: Circular axial fans with external rotor motor HCRE: Wall-mounted axial fans Wall-mounted axial fans with support and blades in sheet steel, especially designed to obtain high energy efficiency. Fan: • HRE: Support ring in sheet steel • HCRE: Sheet steel base plate. • Protection grille to prevent contacts according to standard UNE100250 • Sheet steel impeller • Airflow direction from motor to impeller HRE Motor: • Class F and B motors, with ball bearings, IP-54 protection • High-efficiency external rotor motors • Single-phase 230V.50Hz. and three-phase 400V.50Hz. • Working temperature: -30ºC +60ºC Finish: • Anticorrosive finish in polyester resin, polymerised at 190ºC, after alkaline degreasing and phosphate-free pre-treatment. HCRE Order code HCRE HRE: Circular axial fans with external rotor motor HCRE: Wall-mounted axial fans with external rotor motor 63 Impeller diameter in cm. 6T Number of motor poles 2=2900 r/min. 50 Hz 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz T=Three-phase M=Single-phase Technical characteristics Model Speed (r/min) HRE-25-2T HRE-25-2M HRE-25-4T HRE-25-4M HRE-31-2T HRE-31-2M HRE-31-4T HRE-31-4M HRE-35-4T HRE-35-4M 22 2590 2590 1410 1410 2620 2620 1340 1340 1340 1340 Maximum admissible current (A) 230V 400V Installed power (kW) 0.61 0.35 0.85 0.55 0.32 0.35 0.73 0.42 1.00 0.55 0.32 0.35 0.61 0.35 0.65 0.12 0.12 0.05 0.05 0.15 0.15 0.06 0.06 0.10 0.10 Maximum airflow (m3/h) 1500 1500 1000 1000 2430 2430 1700 1700 2250 2250 Sound Approx. weight pressure level (Kg) dB(A) 69 69 55 55 71 71 60 60 64 64 4.0 4.0 4.0 4.0 4.4 4.4 4.2 4.2 5.4 5.4 HRE HCRE Technical characteristics Model Speed (r/min) HCRE HCRE HCRE HCRE HCRE HCRE HCRE HCRE HCRE HCRE HCRE HCRE HCRE HCRE HCRE HCRE HCRE HCRE 40-4T 40-4M 45-4T 45-4M 45-6T 50-4T 50-4M 50-6T 50-6M 56-4T 56-4M 56-6T 56-6M 63-4T 63-4M 63-6T 63-6M 71-6T 1370 1350 1380 1350 910 1350 1320 920 920 1330 1300 910 910 1350 1360 900 900 910 Maximum admissible current (A) 230V 400V - 0.90 - 1.10 - - 2.00 - 1.10 - 2.50 - 1.50 - 3.70 - 2.50 - Max. absorbed power (W) 0.50 - 0.65 - 0.18 0.85 - 0.62 - 1.10 - 0.85 - 1.60 - 1.40 - 2.00 190 190 290 300 165 420 420 220 220 550 530 320 320 850 800 550 520 1100 Maximum airflow (m3/h) Approx. weight (Kg) 3800 3800 4500 4500 2800 6250 6250 4320 4320 7500 7500 6500 6500 10800 10800 9300 9300 15500 6.0 6.0 7.5 7.5 7.5 10 10 10 10 10.5 10.5 10.5 10.5 15.4 15.4 15.4 15.4 25 Erp. BEP (best efficiency point) characteristics MC EC VSD SR Model MC ηe[%] Efficiency N Degree of efficiency [kW] Electrical power 3 [m /h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship EC VSD SR ηe[%] N (kW) (m3/h) (mmH2O) (RPM) HRE-25-4T HRE-25-4M HRE-31-2T HRE-31-2M HRE-31-4T HRE-31-4M HRE-35-4T HRE-35-4M A A A A A A A A S S S S S S S S - - NO NO - - - - - - 1.00 1.00 - - - - - - 30.8% 26.9% - - - - - - 41.7 37.5 - - - - 0.061 0.064 0.185 0.210 0.098 0.077 0.116 0.120 621 587 1500 1527 933 608 1309 1317 6.37 6.85 13.90 13.57 7.69 13.48 8.09 8.03 1434 1431 2719 2681 1344 1377 1389 1385 HCRE-40-4T HCRE-40-4M HCRE-45-4T HCRE-45-4M HCRE-45-6T HCRE-50-4T HCRE-50-4M HCRE-50-6T HCRE-50-6M HCRE-56-4T HCRE-56-6T HCRE-56-6M HCRE-63-4T HCRE-63-6T HCRE-63-6M HCRE-71-6T A A A A A A A A A A A A C C C C S S S S S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 26.2% 24.9% 28.8% 27.0% 25.6% 34.4% 31.9% 27.9% 25.6% 30.4% 29.4% 27.1% 31.8% 31.2% 30.7% 35.4% 38.1 36.8 38.7 36.7 37.5 44.5 41.8 39.5 37.0 39.4 39.4 36.8 39.2 39.4 38.9 41.9 0.127 0.133 0.270 0.287 0.131 0.258 0.278 0.144 0.157 0.378 0.268 0.291 0.667 0.500 0.507 0.917 2437 2384 2709 2642 2210 3886 3810 2416 2337 5010 4231 4090 6835 5853 5767 9846 5.00 5.12 10.52 10.76 5.60 8.37 8.54 6.12 6.32 8.42 6.83 7.06 11.39 9.77 9.92 12.08 1413 1395 1388 1356 928 1408 1381 948 943 1383 925 918 1382 909 902 925 23 HRE HCRE Dimensions in mm HRE Model A B 320 300 260 145 42 7 HRE-25-2M 320 300 260 145 42 7 HRE-25-4T 320 300 260 145 42 7 HRE-25-4M 320 300 260 145 42 7 HRE-31-2T 397 366 310 152 50 9.5 HRE-31-2M 397 366 310 152 50 9.5 HRE-31-4T 397 366 310 152 50 9.5 HRE-31-4M 397 366 310 152 50 9.5 HRE-35-4T 460 426 360 145 50 9.5 HRE-35-4M 460 426 360 145 50 9.5 HRE-25-2T HCRE HCRE-40 HCRE-45 HCRE-50 HCRE-56 HCRE-63 HCRE-71 24 A B øC øD E HH1 øJ 540 490 430 410 172 - 83 10 575 520 480 460 185 - 90 10 665 615 630 510 189 - 106 10 725 670 570 560 203 - 106 10 805 750 665 645 225 - 110 10 850 810 755 725 - 235 - 10 C EF J HRE HCRE Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. 4P=1500 r/min 25 HRE HCRE Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. 4P=1500 r/min 6P=1000 r/min Accessories See accessories section. INT 26 RM AR RFT/ RFM PANELS PL P RI S SI HCH HCH HFT HCT Robust wall-mounted axial or long-cased fans Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller Fan: • Airflow direction from motor to impeller • PL version impellers in polyamide 6 reinforced with fibreglass and AL version in cast aluminium HCT-40-2T and HCT-45-2T models only in AL version • HCH: Support ring in sheet steel • HFT: Support ring in sheet steel with double clamp and packing boxes for cable entry • HCT: Sheet steel long casing with external terminal board HFT HCT Motor: • Single-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors, with ball bearings and IP55 protection, except single-phase versions from size 45 to size 56, IP54 protection. One-or two-speed depending on the model • Single-phase 230V -50Hz. and three-phase 230/400V.50Hz. (up to 5.5CV.) and 400/690V.-50Hz. (power over 5.5CV.) • Working temperature: -25ºC.+ 50ºC Finish: • Anticorrosive finish in polyester resin, polymerised at 190ºC, after alkaline degreasing and phosphate-free pre-treatment. On request: • Airflow direction from impeller to motor. • 100% reversible impellers • Special windings for different voltages. • ATEX certification, Category 2 HCH HFT HCT Order code HCH 40 HCH: Robust wall-mounted axial fans HFT: Support ring in sheet steel with double clamp HCT: Robust long-cased axial fans Technical characteristics Model 2T Impeller diameter Number of motor poles in cm. 2=2900 r/min. 50 Hz 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz 12=500 r/min. 50 Hz Speed (r/min) HCT HCT HCT HCT HCT HCT HCT HCT HCH HCT HCT HCH HCT HCT HCH HCT HCH HCT HCT HCT HCT HCH HCT HCH HCT HCH HCH HCT Maximum admissible current (A) 230V 400V 690V 25-2T 2670 0.64 0.37 25-2M 2760 0.79 25-4T 1320 0.65 0.38 25-4M 1380 0.65 31-2T 2750 1.21 0.70 31-2M 2780 1.42 31-4T 1320 0.65 0.38 31-4M 1380 0.65 35-2T 2710 1.92 1.11 35-2M 2780 2.53 35-4T 1320 0.65 0.38 35-4M 1380 0.65 40-2T-1.5 2860 4.20 2.40 40-4T-0.33 1350 1.66 0.96 45-2T-2 2770 5.44 3.13 45-2T-3 2885 7.77 4.47 45-2/4T-3 2910 / 1420 5.00 / 1.60 45-4T-0.5 1370 2.02 1.17 45-4M-0.5 1400 2.76 45-6T -0.33 900 1.51 0.87 45-6M -0.33 950 1.30 50-4T-0.75 1380 2.92 1.69 1,5 PL PV T=Three-phase Motor power PL=Plastic PV=Distributor M=Single-phase (CV) impeller AL=Aluminium impeller Installed power (kW) 0.09 0.09 0.09 0.10 0.18 0.18 0.09 0.10 0.37 0.37 0.09 0.10 1.10 0.25 1.50 2.20 2.20 / 0.60 0.37 0.37 0.25 0.25 0.55 Maximum Sound Approx. weight airflow pressure level (Kg) (m3/h) dB(A) HCH HFT HCT 1950 1950 1000 1000 2900 2900 1550 1550 5750 5750 3100 3100 8800 5150 10650 12750 12750/6375 7100 7100 4750 4750 10400 64 64 50 50 70 70 52 52 77 9 77 59 7 59 84 17 64 13 86 88 88/73 68 15 68 15 55 14 55 15 70 7 7 7 7 8 8 8 8 12 12 10 10 25 21 31 34 33 24 24 28 27 HCH HFT HCT Technical characteristics Model Speed (r/min) HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH 28 HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT 56-4T-0.75 56-4M-0.75 56-4T-1 56-4/8T-1 56-4T-1.5 56-4/8T-1.5 56-4T-2 56-4/8T-2 56-6T -0.33 56-6M -0.33 56-6T -0.5 56-6T -0.75 63-4T-1 63-4/8T-1 63-4T-1.5 63-4/8T-1.5 63-4T-2 63-4/8T-2 63-4T-3 63-4/8T-3 63-4T-4 63-4/8T-4 63-6T -0.5 63-6M -0.5 63-6T -0.75 63-6T -1 63-6/12T-1 71-4T-1.5 71-4/8T-1.5 71-4T-2 71-4/8T-2 71-4T-3 71-4/8T-3 71-4T-4 71-4/8T-4 71-6T -0.75 71-6M -0.75 71-6T -1 71-6/12T-1 71-6T -1.5 71-6/12T-1.5 80-4T-3 80-4/8T-3 80-4T-4 80-4/8T-4 80-4T-5.5 80-4/8T-5.5 80-6T -1 80-6/12T-1 80-6T -1.5 80-6/12T-1.5 80-6T -2 80-6/12T-2 80-6T -3 80-6/12T-3 80-8T-0.5 80-8T-0.75 80-8T-1 90-4T-4 90-4/8T-4 90-4T-5.5 90-4/8T-5.5 90-4T-7.5 90-4/8T-7.5 90-4T-10 Maximum admissible current (A) 230V 400V 690V 1380 2.92 1.69 1450 4.40 1410 3.10 1.79 1430 / 710 2.00 / 0.90 1400 4.03 2.32 1440 / 710 2.90 / 1.30 1430 5.96 3.44 1420 / 700 3.50 / 1.50 900 1.51 0.87 950 1.85 900 2.24 1.30 900 2.99 1.73 1410 3.10 1.79 1430 / 710 2.00 / 0.90 1400 4.03 2.32 1440 / 710 2.90 / 1.30 1430 5.96 3.44 1420 / 700 3.50 / 1.50 1445 8.36 4.83 1430 / 710 4.90 / 1.70 1445 10.96 6.33 1430 / 710 6.50 / 2.30 900 2.24 1.30 900 2.69 900 2.99 1.73 945 3.90 2.20 935 / 435 2.20 / 0.87 1400 4.03 2.32 1440 / 710 2.90 / 1.30 1430 5.96 3.44 1420 / 700 3.50 / 1.50 1445 8.36 4.83 1430 / 710 4.90 / 1.70 1445 10.96 6.33 1430 / 710 6.50 / 2.30 900 2.99 1.73 900 3.84 945 3.90 2.20 935 / 435 2.20 / 0.87 945 4.88 2.82 950 / 470 3.00 / 1.15 1445 8.36 4.83 1430 / 710 4.90 / 1.70 1445 10.96 6.33 1430 / 710 6.50 / 2.30 1440 14.10 8.12 1430 / 710 8.20 / 2.90 945 3.90 2.20 935 / 435 2.20 / 0.87 945 4.88 2.82 950 / 470 3.00 / 1.15 955 6.42 3.71 970 / 470 4.60 / 1.90 955 9.30 5.30 940 / 470 5.60 / 2.20 700 2.77 1.60 695 3.53 2.04 705 4.68 2.70 1445 10.96 6.33 1430 / 710 6.50 / 2.30 1440 14.10 8.12 1430 / 710 8.20 / 2.90 1440 11.60 6.72 1450 / 720 11.80 / 3.80 1455 14.20 8.20 Installed power (kW) 0.55 0.55 0.75 0.75 / 0.20 1.10 1.10 / 0.25 1.50 1.50 / 0.37 0.25 0.25 0.37 0.55 0.75 0.75 / 0.20 1.10 1.10 / 0.25 1.50 1.50 / 0.37 2.20 2.20 / 0.45 3.00 3.00 / 0.60 0.37 0.37 0.55 0.75 0.75 / 0.15 1.10 1.10 / 0.25 1.50 1.50 / 0.37 2.20 2.20 / 0.45 3.00 3.00 / 0.60 0.55 0.55 0.75 0.75 / 0.15 1.10 1.10 / 0.18 2.20 2.20 / 0.45 3.00 3.00 / 0.60 4.00 4.00 / 0.80 0.75 0.75 / 0.15 1.10 1.10 / 0.18 1.50 1.50 / 0.25 2.20 2.20 / 0.37 0.37 0.55 0.75 3.00 3.00 / 0.60 4.00 4.00 / 0.80 5.50 5.50 / 1.10 7.50 Maximum Sound Approx. weight airflow pressure level (Kg) 3 (m /h) dB(A) HCH HFT HCT 11050 11050 12950 12950/6475 14000 14000/7000 15300 15300/7650 8500 8400 9300 10000 14150 14150/7075 17000 17000/8500 18900 18900/9450 22100 22100/11050 25400 25400/12700 12150 12150 12750 13800 13800/6900 19750 19600/9800 21100 21100/10550 23950 24150/12075 29400 29550/14775 15150 15150 17250 17150/8575 20950 20950/10475 28000 28000/14000 32700 32700/16350 37200 37200/18600 20600 20600/10300 24250 24250/12125 28000 28000/14000 32500 32500/16250 16600 19600 22150 37750 37750/18875 41850 41850/20925 47000 47000/23500 53000 72 72 73 73/58 74 74/59 75 75/60 61 61 61 62 73 73/58 74 74/59 75 75/60 76 76/61 77 77/62 64 64 65 66 66/51 78 78/63 79 79/64 81 81/66 82 82/67 67 67 68 68/53 69 69/54 82 82/67 83 83/68 84 84/69 71 71/56 72 72/57 73 73/58 74 74/59 69 70 71 87 87/72 89 89/74 91 91/76 92 21 21 22 23 26 24 28 28 18 19 20 22 27 27 30 29 33 32 41 38 43 42 25 25 27 33 32 33 32 36 35 45 42 47 46 29 29 36 35 38 37 53 50 55 54 60 66 44 43 46 45 52 62 57 62 43 45 50 62 61 67 73 83 93 94 23 33 23 33 24 34 25 35 28 37 26 35 30 39 30 39 20 30 21 31 22 32 24 34 29 42 29 43 32 45 31 44 35 48 34 48 43 57 40 54 45 59 44 57 27 40 27 40 29 42 35 48 34 47 35 52 34 51 38 55 37 54 47 64 44 61 49 66 48 64 31 49 31 49 38 55 37 54 40 57 39 56 55 72 52 69 57 74 56 73 62 79 68 85 46 64 45 63 48 66 47 65 54 71 64 81 59 76 64 81 45 63 47 65 52 69 66 90 65 88 71 95 77 101 87 109 97 119 98 120 HCH HFT HCT Technical characteristics Model Speed (r/min) HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HCH HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HFT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT HCT Maximum admissible current (A) 230V 400V 690V Installed power (kW) 90-4/8T-10 1460 / 725 15.30 / 5.40 7.50 / 1.50 90-6T -2 955 6.42 3.71 1.50 90-6/12T-2 970 / 470 4.60 / 1.90 1.50 / 0.25 90-6T -3 955 9.30 5.30 2.20 90-6/12T-3 940 / 470 5.60 / 2.20 2.20 / 0.37 90-6T -4 960 12.70 7.30 3.00 90-6/12T-4 960 / 480 9.00 / 3.50 3.00 / 0.55 90-8T-1 705 4.68 2.70 0.75 90-8T-1.5 705 5.63 3.25 1.10 90-8T-2 705 7.10 4.10 1.50 90-8T-3 705 9.53 5.50 2.20 100-4T-7.5 1440 11.60 6.72 5.50 100-4/8T-7.5 1450 / 720 11.80 / 3.80 5.50 / 1.10 100-4T-10 1455 14.20 8.20 7.50 100-4/8T-10 1460 / 725 15.30 / 5.40 7.50 / 1.50 100-4T-15 1460 20.20 11.60 11.00 100-4/8T-15 1470 / 725 23.20 / 8.70 11.00 / 2.80 100-4T-20 1460 27.50 15.90 15.00 100-4/8T-20 1460 / 72531.72 / 11.75 15.00 / 3.80 100-6T -3 955 9.30 5.30 2.20 100-6/12T-3 940 / 470 5.60 / 2.20 2.20 / 0.37 100-6T -4 960 12.70 7.30 3.00 100-6/12T-4 960 / 480 9.00 / 3.50 3.00 / 0.55 100-6T -5.5 960 16.50 9.46 4.00 100-6/12T-5.5 970 / 480 4.00 / 11.00 4.00 / 0.65 100-8T-1.5 705 5.63 3.25 1.10 100-8T-2 705 7.10 4.10 1.50 100-8T-3 705 9.53 5.50 2.20 100-8T-4 705 12.82 7.40 3.00 Maximum Sound Approx. weight airflow pressure level (Kg) 3 (m /h) dB(A) HCH HFT HCT 53000/26500 30000 30000/15000 35000 35000/17500 40000 40000/20000 22400 24150 26300 30150 52500 52500/26250 58500 58500/29250 68000 68000/34000 71850 72450/36225 40500 40500/20250 46950 46950/23475 52000 52000/26000 32500 33850 35150 37800 92/77 77 77/62 78 78/63 79 79/64 71 72 73 74 92 92/77 93 93/78 94 94/79 95 95/80 82 82/67 83 83/68 84 84/69 76 77 77 78 98 59 69 64 69 88 87 57 60 71 98 91 101 102 106 125 125 144 140 72 77 96 95 104 100 67 79 106 114 102 63 73 68 73 92 91 61 64 75 102 95 105 106 110 129 129 148 144 76 81 100 99 108 104 71 83 110 118 124 87 97 92 97 114 113 85 88 99 124 121 128 131 135 160 160 179 175 103 108 125 124 133 129 99 110 135 143 Erp. BEP (best efficiency point) characteristics MC EC VSD SR Model 25-4M 25-4T 31-2M 31-2T 31-4M 31-4T 35-2M 35-2T 35-4M 35-4T 40-2T-1.5 40-4T-0.33 45-2T-2 45-2T-3 45-2/4T-3 45-4T-0.5 45-4M-0.5 50-4T-0.75 56-4T-0.75 56-4M-0.75 56-4T-1 56-4T-1.5 56-6T -0.33 56-6M -0.33 ηe[%] Efficiency N Degree of efficiency [kW] Electrical power 3 [m /h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship MC EC VSD SR - - A A - - A A A A A A A A A A A A A A A A A A - - S S - - S S S S S S S S S S S S S S S S S S - - NO NO - - NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO - - 1.00 1.00 - - 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 ηe[%] - - 27.6% 29.4% - - 36.5% 37.1% 25.6% 27.4% 33.9% 32.0% 36.9% 38.7% 37.7% 33.4% 29.6% 29.5% 33.2% 32.7% 33.2% 31.3% 31.4% 26.6% N - - 37.5 39.5 - - 44.6 45.2 37.4 39.3 40.2 41.7 42.0 43.1 42.0 41.8 37.6 37.0 40.6 40.1 40.3 37.7 41.7 36.3 (kW) (m3/h) (mmH2O) (RPM) 0.102 0.099 0.266 0.250 0.111 0.103 0.524 0.515 0.137 0.128 1.029 0.289 1.573 2.047 2.110 0.475 0.538 0.649 0.660 0.669 0.759 0.973 0.237 0.293 566 586 1652 1708 1004 1013 2983 2998 1851 1857 4386 3401 5401 8183 8454 4228 4257 3716 6808 6622 6599 7130 3564 4104 3.59 3.45 16.33 15.79 4.09 4.06 23.52 23.40 6.96 6.94 29.24 10.00 39.47 35.55 34.61 13.80 13.73 18.91 11.81 12.13 14.03 15.69 7.69 6.98 1386 1358 2805 2774 1418 1397 2791 2737 1425 1400 2896 1396 2805 2910 2934 1392 1410 1406 1405 1422 1423 1427 919 933 29 HCH HFT HCT Erp. BEP (best efficiency point) characteristics Model 63-4T-1 63-4/8T-1 63-4T-1.5 63-4/8T-1.5 63-4T-2 63-4/8T-2 63-4T-3 63-4/8T-3 63-6T -0.5 63-6M -0.5 63-6T -0.75 63-6T -1 71-4T-1.5 71-4/8T-1.5 71-4T-2 71-4/8T-2 71-4T-3 71-4/8T-3 71-4T-4 71-4/8T-4 71-6T -0.75 71-6M -0.75 71-6T -1 71-6/12T-1 71-6T -1.5 71-6/12T-1.5 80-4T-3 80-4/8T-3 80-4T-4 80-4/8T-4 80-4T-5.5 80-4/8T-5.5 80-6T -1 80-6/12T-1 80-6T -1.5 80-6/12T-1.5 80-6T -2 80-6/12T-2 80-6T -3 80-6/12T-3 80-8T-0.5 80-8T-0.75 80-8T-1 90-4T-4 90-4/8T-4 90-4T-5.5 90-4/8T-5.5 90-4T-7.5 90-4/8T-7.5 90-4T-10 90-4/8T-10 90-6T -2 90-6/12T-2 90-6T -3 90-6/12T-3 90-6T -4 90-6/12T-4 90-8T-1 90-8T-1.5 90-8T-2 90-8T-3 100-4T-7.5 30 MC EC VSD SR C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 ηe[%] 45.0% 38.2% 45.3% 41.4% 44.6% 38.4% 35.7% 33.4% 32.7% 32.2% 32.6% 29.1% 53.4% 45.1% 50.1% 43.7% 45.6% 41.7% 38.4% 37.5% 35.7% 33.6% 35.3% 33.6% 37.6% 30.6% 56.7% 50.1% 54.0% 50.1% 51.4% 50.0% 48.0% 43.1% 46.7% 43.1% 42.2% 39.2% 36.1% 33.3% 36.0% 33.9% 35.4% 58.1% 53.2% 56.2% 53.9% 53.2% 47.6% 50.3% 46.3% 50.9% 46.5% 43.0% 38.8% 38.7% 33.4% 42.4% 34.9% 37.3% 36.6% 51.0% N 52.0 44.7 51.1 47.1 49.8 43.2 40.0 37.5 41.1 40.6 40.6 36.2 59.2 50.4 55.3 48.5 49.8 45.6 41.3 40.4 43.0 40.7 42.3 40.5 43.6 36.1 60.7 53.8 57.1 53.0 53.8 52.3 54.5 49.3 52.1 48.4 46.8 43.7 40.1 37.1 43.8 40.7 41.6 61.1 55.9 58.5 56.1 54.6 48.7 51.0 46.7 55.7 51.0 46.8 42.4 42.0 36.2 48.8 40.5 42.8 41.5 52.4 (kW) (m3/h) (mmH2O) (RPM) 0.794 0.938 1.179 1.286 1.493 1.734 2.105 2.248 0.474 0.482 0.547 0.748 1.217 1.411 1.508 1.731 2.216 2.478 3.404 3.534 0.710 0.755 0.796 0.829 1.123 1.373 2.309 2.621 3.246 3.496 4.207 4.324 0.939 1.043 1.380 1.492 1.845 1.979 2.408 2.598 0.584 0.830 1.070 3.362 3.681 4.306 4.487 6.004 6.705 7.864 8.546 1.777 1.944 2.492 2.760 3.091 3.606 0.980 1.332 1.375 1.675 5.965 8989 8924 10593 10448 11688 11566 14963 14534 6417 6339 6936 7611 11355 11393 13256 13141 14513 14275 18556 18165 8036 7945 8550 8626 12806 12573 16178 15754 19442 19059 20980 20666 12168 12343 15312 15127 17013 16702 18724 18276 10464 12481 14234 20308 20152 24635 24524 26945 26824 33102 32957 18106 18044 22079 21982 22590 23773 13430 14032 14674 16898 27281 14.61 14.74 18.50 18.74 20.93 21.13 18.46 18.99 8.88 8.99 9.46 10.50 21.04 20.50 20.95 21.15 25.59 26.60 25.85 26.80 11.60 11.73 12.07 11.87 12.11 12.28 29.73 30.61 33.11 33.78 37.85 38.41 13.62 13.38 15.45 15.63 16.79 17.06 17.07 17.42 7.37 8.28 9.79 35.36 35.69 36.06 36.24 43.56 43.74 43.89 44.09 18.37 18.42 17.82 17.90 19.47 18.62 11.36 12.18 12.84 13.32 40.95 1424 1440 1412 1451 1442 1433 1456 1446 921 915 933 958 1409 1446 1442 1433 1453 1441 1447 1436 913 908 956 952 956 952 1451 1437 1449 1437 1445 1437 948 939 946 952 956 971 960 948 701 696 707 1447 1433 1444 1435 1442 1452 1458 1463 957 971 958 945 965 961 715 710 719 724 1443 HCH HFT HCT Erp. BEP (best efficiency point) characteristics Model MC 100-4/8T-7.5 100-4T-10 100-4/8T-10 100-4T-15 100-4/8T-15 100-4T-20 100-4/8T-20 100-6T -3 100-6/12T-3 100-6T -4 100-6/12T-4 100-6T -5.5 100-6/12T-5.5 100-8T-1.5 100-8T-2 100-8T-3 100-8T-4 C C C C C C C C C C C C C C C C C EC VSD SR S S S S S S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 ηe[%] 45.7% 47.5% 43.0% 47.7% 43.0% 44.5% 41.5% 47.3% 41.7% 43.5% 38.7% 41.7% 39.1% 47.6% 42.7% 34.2% 33.3% N (kW) (m3/h) 46.8 48.1 43.3 47.6 42.9 44.3 41.2 51.1 45.3 46.3 41.2 43.8 41.1 52.9 47.2 38.0 36.6 6.658 7.982 8.817 11.541 12.785 13.387 14.690 2.461 2.789 3.541 3.980 4.637 4.939 1.452 1.923 2.567 3.027 27102 36164 35646 44388 44106 46050 43763 23849 23616 28826 28654 32856 32699 19345 20901 20286 21510 (mmH2O) 41.24 38.48 39.03 45.52 45.84 47.49 51.13 17.92 18.11 19.61 19.74 21.61 21.71 13.11 14.42 15.90 17.21 (RPM) 1452 1458 1465 1462 1471 1468 1467 959 944 960 961 965 971 707 706 710 715 Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at an equivalent distance of twice the fan’s span plus the impeller’s diameter, with a minimum of 1.5 m. Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. Model 25-2 25-4 31-2 31-4 35-2 35-4 40-2 40-4 45-2-2 45-2-3 03/04/1945 (2v) 45-4-0.5 45-6 50-4 56-4-0.75 56-4-1 56-8-1 (2v) 56-4-1.5 56-8-1.5 (2v) 56-4-2 02/08/1956 (2v) 56-6-0.33 56-6-0.5 56-6-0.75 63-4-1 01/08/1963 (2v) 63-4-1.5 63-8-1.5 (2v) 63-4-2 02/08/1963 (2v) 63-4-3 03/08/1963 (2v) 63-4-4 04/08/1963 (2v) 63-6-0.5 63-6-0.75 63-6-1 01/12/1963 (2v) 71-4-1.5 71-8-1.5 (2v) 71-4-2 02/08/1971 (2v) 71-4-3 03/08/1971 (2v) 71-4-4 04/08/1971 (2v) 71-6-0.75 71-6-1 01/12/1971 (2v) 71-6-1.5 71-12-1.5 (2v) 80-4-3 63 35 21 41 23 48 30 55 35 51 53 38 33 20 37 47 48 33 49 34 50 35 36 36 37 50 35 51 36 52 37 53 38 54 39 41 42 43 28 55 40 56 41 58 43 59 44 44 45 30 46 31 59 125 250500 1000200040008000 50 69 68 69 68 63 54 36 55 54 55 54 49 40 56 75 74 75 74 69 60 38 57 56 57 56 51 42 63 82 81 82 81 76 67 45 64 63 64 63 58 49 70 89 88 89 88 83 74 50 69 68 69 68 63 54 68 80 88 93 93 89 82 70 82 90 95 95 91 84 55 67 75 80 80 76 69 50 62 70 75 75 71 64 37 49 57 62 62 58 51 54 67 74 79 80 75 68 67 75 80 82 79 72 61 68 76 81 83 80 73 62 53 61 66 68 65 58 47 69 77 82 84 81 74 63 54 62 67 69 66 59 48 70 78 83 85 82 75 64 55 63 68 70 67 60 49 56 64 69 71 68 61 50 56 64 69 71 68 61 50 57 65 70 72 69 62 51 70 78 83 85 82 75 64 55 63 68 70 67 60 49 71 79 84 86 83 76 65 56 64 69 71 68 61 50 72 80 85 87 84 77 66 57 65 70 72 69 62 51 73 81 86 88 85 78 67 58 66 71 73 70 63 52 74 82 87 89 86 79 68 59 67 72 74 71 64 53 61 69 74 76 73 66 55 62 70 75 77 74 67 56 63 71 76 78 75 68 57 48 56 61 63 60 53 42 75 83 88 90 87 80 69 60 68 73 75 72 65 54 76 84 89 91 88 81 70 61 69 74 76 73 66 55 78 86 91 93 90 83 72 63 71 76 78 75 68 57 79 87 92 94 91 84 73 64 72 77 79 76 69 58 64 72 77 79 76 69 58 65 73 78 80 77 70 59 50 58 63 65 62 55 44 66 74 79 81 78 71 60 51 59 64 66 63 56 45 79 87 92 94 91 84 73 Model 03/08/1980 (2v) 80-4-4 04/08/1980 (2v) 80-4-5.5 80-8-5.5 (2v) 80-6-1 01/12/1980 (2v) 80-6-1.5 80-12-1.5 (2v) 80-6-2 02/12/1980 (2v) 80-6-3 03/12/1980 (2v) 80-8-0.5 80-8-0.75 80-8-1 90-4-4 04/08/1990 (2v) 90-4-5.5 90-8-5.5 (2v) 90-4-7.5 90-8-7.5 (2v) 90-4-10 10/08/1990 (2v) 90-6-2 02/12/1990 (2v) 90-6-3 03/12/1990 (2v) 90-6-4 04/12/1990 (2v) 90-8-1 90-8-1.5 90-8-2 90-8-3 100-4-7.5 100-8-7.5 (2v) 100-4-10 100-8-10 (2v) 100-4-15 100-8-15 (2v) 100-4-20 100-8-20 (2v) 100-6-3 100-12-3 (2v) 100-6-4 100-12-4 (2v) 100-6-5.5 100-12-5.5 (2v) 100-8-1.5 100-8-2 100-8-3 100-8-4 63 44 60 45 61 46 48 33 49 34 50 35 51 36 46 47 48 65 50 67 52 69 54 70 55 55 40 56 41 57 42 49 50 51 52 72 57 73 58 74 59 75 60 62 47 63 48 64 49 56 57 57 58 125 250500 1000200040008000 64 72 77 79 76 69 58 80 88 93 95 92 85 74 65 73 78 80 77 70 59 81 89 94 96 93 86 75 66 74 79 81 78 71 60 68 76 81 83 80 73 62 53 61 66 68 65 58 47 69 77 82 84 81 74 63 54 62 67 69 66 59 48 70 78 83 85 82 75 64 55 63 68 70 67 60 49 71 79 84 86 83 76 65 56 64 69 71 68 61 50 66 74 79 81 78 71 60 67 75 80 82 79 72 61 68 76 81 83 80 73 62 86 93 98 101 97 90 79 71 78 83 86 82 75 64 88 95 100 103 99 92 81 73 80 85 88 84 77 66 90 97 102 105 101 94 83 75 82 87 90 86 79 68 91 98 103 106 102 95 84 76 83 88 91 87 80 69 76 83 88 91 87 80 69 61 68 73 76 72 65 54 77 84 89 92 88 81 70 62 69 74 77 73 66 55 78 85 90 93 89 82 71 63 70 75 78 74 67 56 70 77 82 85 81 74 63 71 78 83 86 82 75 64 72 79 84 87 83 76 65 73 80 85 88 84 77 66 92 100 105 107 104 97 86 77 85 90 92 89 82 71 93 101 106 108 105 98 87 78 86 91 93 90 83 72 94 102 107 109 106 99 88 79 87 92 94 91 84 73 95 103 108 110 107 100 89 80 88 93 95 92 85 74 82 90 95 97 94 87 76 67 75 80 82 79 72 61 83 91 96 98 95 88 77 68 76 81 83 80 73 62 84 92 97 99 96 89 78 69 77 82 84 81 74 63 76 84 89 91 88 81 70 77 85 90 92 89 82 71 77 85 90 92 89 82 71 78 86 91 93 90 83 72 31 HCH HFT HCT Dimensions in mm HCH Model HCH-35-2 HCH-35-4 HCH-40-2 HCH-40-4 HCH-45-4 HCH-45-6 HCH-56-4 HCH-56-6 HCH-63-4 HCH-63-6 HCH-71-4 HCH-71-6 HCH-80-4 HCH-80-6 HCH-80-8 HCH-90-4 HCH-90-6 HCH-90-8 HCH-100-4 HCH-100-6 HCH-100-8 ØA ØB ØC ØD 0,16 0,33 0,5 0,75 1 425 395 358 355 - - 285 - - 425 395 358 355 257 - - - - 490 450 414 410 - - - - - 490 450 414 410 - 295 - - - 540 500 464 460 - - 280 - - 540 500 464 460 - 280 - - - 660 620 564 560 - - - 310 310 660 620 564 560 - 285 310 310 - 730 690 645 640 - - - - 325 730 690 645 640 - - 325 325 335 810 770 715 710 - - - - - 810 770 715 710 - - - 315 330 900 860 805 800 - - - - - 900 860 805 800 - - - - 355 900 860 805 800 - - 380 380 410 1015 970 906 900 - - - - - 1015 970 906 900 - - - - - 1015 970 906 900 - - - - 410 1115107010061000 - - - - 1115107010061000 - - - - - 1115107010061000 - - - - - 1,5 - - 314 - - - 330 - 325 - 330 350 - 375 - - - 410 - - 405 E 2 - - - - - - 350 - 355 - 350 - - 425 - - 425 395 - - 405 3 - - - - - - - - 405 - 415 - 425 445 - - 430 460 - 440 470 4 - - - - - - - - 405 - 415 - 425 - - 425 465 - - 480 470 5,5 7,5 10 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 445 - - - - - - - - 430 465 465 - - - - - - - 480 480 480 - - - - - 15 20 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 590 590 - - - - F 110 110 120 120 120 120 120 120 150 150 150 150 180 180 180 180 180 180 200 200 200 ØJ 10 10 12 12 12 12 12 12 12 12 12 12 12 12 12 15 15 15 15 15 15 N 8 X 45º 8 X 45º 8 X 45º 8 X 45º 8 X 45º 8 X 45º 12 X 30º 12 X 30º 12 X 30º 12 X 30º 16 X 22º30’ 16 X 22º30’ 16 X 22º30’ 16 X 22º30’ 16 X 22º30’ 16 X 22º30’ 16 X 22º30’ 16 X 22º30’ 16 X 22º30’ 16 X 22º30’ 16 X 22º30’ HFT Model HFT-56-4 HFT-56-6 HFT-63-4 HFT-63-6 HFT-71-4 HFT-71-6 HFT-80-4 HFT-80-6 HFT-80-8 HFT-90-4 HFT-90-6 HFT-90-8 HFT-100-4 HFT-100-6 HFT-100-8 HCT 32 E øA øB øC øD0,33 0,50,75 11,5 2 3 45,5 7,51015 20 660 620 564 560 - - 344 344 376 376 - - - - - - - 660 620 564 560 310 344 344 - - - - - - - - - - 730 690 645 640 - - - 325 398 398 430 430 - - - - - 730 690 645 640 - 325 325 398 - - - - - - - - - 810 770 715 710 - - - - 400 400 440 440 - - - - - 810 770 715 710 - - 325 400 400 - - - - - - - - 900 860 805 800 - - - - - - 425 425 445 - - - - 900 860 805 800 - - - 390 390 425 445 - - - - - - 900 860 805 800 - 390 390 425 - - - - - - - - - 1015 970 906 900 - - - - - - - 430 440 470 470 - - 1015 970 906 900 - - - - - 430 440 470 - - - - - 1015 970 906 900 - - - 430 430 440 470 - - - - - - 1115 1070 1006 1000 - - - - - - - - - 485 485 590 590 1115 1070 1006 1000 - - - - - - 440 485 485 - - - - 1115 1070 1006 1000 - - - - 420 440 485 485 - - - - - Model HCT-25 HCT-31 HCT-35 HCT-40 HCT-45 HCT-50 HCT-56 HCT-63 HCT-71 HCT-80 HCT-90 HCT-100 HCT-100-4T-15 HCT-100-4T-20 ØA 310 350 425 490 540 600 660 730 810 900 1015 1115 1115 1115 ØB ØD 280 240 320 280 395 355 450 410 500 460 560 514 620 560 690 640 770 710 860 800 970 900 1070 1000 1070 1000 1070 1000 E E1 230 10 270 - 280 - 320 - 360 - 360 - 400 - 430 - 500 - 500 - 500 - 550 - 650 - 650 - ØJ 10 10 10 12 12 12 12 12 12 12 15 15 15 15 N 4x90º 4x90º 8x45º 8x45º 8x45º 12x30º 12x30º 12x30º 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ FøJ 150 12 150 12 150 12 150 12 150 12 150 12 180 12 180 12 180 12 180 15 180 15 180 15 200 15 200 15 200 15 N 12x30º 12x30º 12x30º 12x30º 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ HCH HFT HCT Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. 2 Poles=3000 r/min 2 Poles=3000 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 33 HCH HFT HCT Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. 4 Poles=1500 r/min 34 4 Poles=1500 r/min 4 Poles=1500 r/min 4 Poles=1500 r/min 6 Poles=1000 r/min 6 Poles=1000 r/min HCH HFT HCT Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. 6 Poles=1000 r/min 6 Poles=1000 r/min 6 Poles=1000 r/min 6 Poles=1000 r/min 8 Poles=750 r/min 8 Poles=750 r/min 35 HCH HFT HCT Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. 4 Poles (2-speed motor)=2/4 Poles 36 8 Poles (2-speed motor)=4/8 Poles 8 Poles (2-speed motor)=4/8 Poles 8 Poles (2-speed motor)=4/8 Poles 8 Poles (2-speed motor)=4/8 Poles 8 Poles (2-speed motor)=4/8 Poles HCH HFT HCT Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. 8 Poles (2-speed motor)=4/8 Poles 12 Poles (2-speed motor)=6/12 Poles 12 Poles (2-speed motor)=6/12 Poles 12 Poles (2-speed motor)=6/12 Poles 12 Poles (2-speed motor)=6/12 Poles 12 Poles (2-speed motor)=6/12 Poles Accessories See accessories section. INT S RM AR SI PV C2V RFT/ RFM PANELS PL P PT/H R RI RT BTUB BAC PS 37 CJHCH CJHCH Axial ventilation units with soundproofed box Ventilation units with internal soundproofing, with dismountable inspection hatches. Fan: • Galvanised steel structure with thermal insulation and soundproofing • Impellers in polyamide 6 reinforced with fibre glass • Ventilation units designed for working in both horizontal and vertical positions • Airflow direction from motor to impeller Motor: • S ingle-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors with ball bearings, IP55 protection, except single-phase models from size 45 to size 56, IP54 protection. One-or two-speed depending on the model • Single-phase 230V -50Hz. and threephase 230/400V.50Hz. (up to 5.5CV.) and 400/690V.-50Hz. (power over 5.5CV.) • Working temperature: -25ºC.+ 50ºC Finish: • Anticorrosive galvanized sheet steel. On request: • AL version cast aluminium impellers • Airflow direction from impeller to motor. • 100% reversible impellers. • Special windings for different voltages Order code CJHCH 56 Axial fans with soundproofed box Impeller diameter in cm. 4T Number of motor poles 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz 12=500 r/min. 50 Hz 0.75 T=Three-phase M=Single-phase Motor power (CV) Technical characteristics Model CJHCH-56-4T-0.75 CJHCH-56-4M-0.75 CJHCH-56-4T-1 CJHCH-56-4/8T-1 CJHCH-56-4T-1.5 CJHCH-56-4/8T-1.5 CJHCH-56-4T-2 CJHCH-56-4/8T-2 CJHCH-56-6T-0.33 CJHCH-56-6M-0.33 CJHCH-56-6T-0.5 CJHCH-56-6T-0.75 CJHCH-63-4T-1 CJHCH-63-4/8T-1 CJHCH-63-4T-1.5 CJHCH-63-4/8T-1.5 CJHCH-63-4T-2 CJHCH-63-4/8T-2 CJHCH-63-4T-3 CJHCH-63-4/8T-3 CJHCH-63-4T-4 CJHCH-63-4/8T-4 CJHCH-63-6T-0.5 CJHCH-63-6M-0.5 CJHCH-63-6T-0.75 CJHCH-63-6T-1 CJHCH-63-6/12T-1 CJHCH-71-4T-1.5 38 Speed (r/min) Maximum admissible current (A) 230V 400V 690V 1380 2.92 1.69 1450 4.40 1410 3.10 1.79 1430 / 710 2.00 / 0.90 1400 4.03 2.32 1440 / 710 2.90 / 1.30 1430 5.96 3.44 1420 / 700 3.50 / 1.50 900 1.51 0.87 950 1.85 900 2.24 1.30 900 2.99 1.73 1410 3.10 1.79 1430 / 710 2.00 / 0.90 1400 4.03 2.32 1440 / 710 2.90 / 1.30 1430 5.96 3.44 1420 / 700 3.50 / 1.50 1445 8.36 4.83 1430 / 710 4.90 / 1.70 1445 10.96 6.33 1430 / 710 6.50 / 2.30 900 2.24 1.30 900 2.69 900 2.99 1.73 945 3.90 2.20 935 / 435 2.20 / 0.87 1400 4.03 2.32 Installed power (kW) 0.55 0.55 0.75 0.75 / 0.20 1.10 1.10 / 0.25 1.50 1.50 / 0.37 0.25 0.25 0.37 0.55 0.75 0.75 / 0.20 1.10 1.10 / 0.25 1.50 1.50 / 0.37 2.20 2.20 / 0.45 3.00 3.00 / 0.60 0.37 0.37 0.55 0.75 0.75 / 0.15 1.10 Maximum airflow (m3/h) 11050 11050 12950 12950/6475 14000 14000/7000 15300 15300/7650 8500 8400 9300 10000 14150 14150/7075 17000 17000/8500 18900 18900/9450 22100 22100/11050 25400 25400/12700 12150 12150 12750 13800 13800/6900 19750 Sound Approx. weight pressure level (Kg) dB(A) 69 69 70 70/55 71 71 / 56 72 72 / 57 59 59 59 60 70 70 / 55 71 71 / 56 72 72 / 57 73 73 / 58 74 74 / 59 62 62 63 64 64 / 49 75 52.1 52.1 53.1 54.0 56.8 55.3 59.3 59.0 48.8 49.8 51.1 53.1 57.5 58.4 61.2 59.7 63.7 63.4 72.4 69.4 74.4 72.8 55.5 55.5 57.5 64.2 63.2 77.3 CJHCH Technical characteristics Model Speed (r/min) CJHCH-71-4/8T-1.5 CJHCH-71-4T-2 CJHCH-71-4/8T-2 CJHCH-71-4T-3 CJHCH-71-4/8T-3 CJHCH-71-4T-4 CJHCH-71-4/8T-4 CJHCH-71-6T-0.75 CJHCH-71-6M-0.75 CJHCH-71-6T-1 CJHCH-71-6/12T-1 CJHCH-71-6T-1.5 CJHCH-71-6/12T-1.5 CJHCH-80-4T-3 CJHCH-80-4/8T-3 CJHCH-80-4T-4 CJHCH-80-4/8T-4 CJHCH-80-4T-5.5 CJHCH-80-4/8T-5.5 CJHCH-80-6T-1 CJHCH-80-6/12T-1 CJHCH-80-6T-1.5 CJHCH-80-6/12T-1.5 CJHCH-80-6T-2 CJHCH-80-6/12T-2 CJHCH-80-6T-3 CJHCH-80-6/12T-3 CJHCH-80-8T-0.5 CJHCH-80-8T-0.75 CJHCH-80-8T-1 CJHCH-90-4T-4 CJHCH-90-4/8T-4 CJHCH-90-4T-5.5 CJHCH-90-4/8T-5.5 CJHCH-90-4T-7.5 CJHCH-90-4/8T-7.5 CJHCH-90-4T-10 CJHCH-90-4/8T-10 CJHCH-90-6T-2 CJHCH-90-6/12T-2 CJHCH-90-6T-3 CJHCH-90-6/12T-3 CJHCH-90-6T-4 CJHCH-90-6/12T-4 CJHCH-90-8T-1 CJHCH-90-8T-1.5 CJHCH-90-8T-2 CJHCH-90-8T-3 CJHCH-100-4T-7.5 CJHCH-100-4/8T-7.5 CJHCH-100-4T-10 CJHCH-100-4/8T-10 CJHCH-100-4T-15 CJHCH-100-4/8T-15 CJHCH-100-4T-20 CJHCH-100-4/8T-20 CJHCH-100-6T-3 CJHCH-100-6/12T-3 CJHCH-100-6T-4 CJHCH-100-6/12T-4 CJHCH-100-6T-5.5 CJHCH-100-6/12T-5.5 CJHCH-100-8T-1.5 CJHCH-100-8T-2 CJHCH-100-8T-3 CJHCH-100-8T-4 Maximum admissible current (A) 230V 400V 690V Installed power (kW) 1440 / 710 2.90 / 1.30 1.10 / 0.25 1430 5.96 3.44 1.50 1420 / 700 3.50 / 1.50 1.50 / 0.37 1445 8.36 4.83 2.20 1430 / 710 4.90 / 1.70 2.20 / 0.45 1445 10.96 6.33 3.00 1430 / 710 6.50 / 2.30 3.00 / 0.60 900 2.99 1.73 0.55 900 3.84 0.55 945 3.90 2.20 0.75 935 / 435 2.20 / 0.87 0.75 / 0.15 945 4.88 2.82 1.10 950 / 470 3.00 / 1.15 1.10 / 0.18 1445 8.36 4.83 2.20 1430 / 710 4.90 / 1.70 2.20 / 0.45 1445 10.96 6.33 3.00 1430 / 710 6.50 / 2.30 3.00 / 0.60 1440 14.10 8.12 4.00 1430 / 710 8.20 / 2.90 4.00 / 0.80 945 3.90 2.20 0.75 935 / 435 2.20 / 0.87 0.75 / 0.15 945 4.88 2.82 1.10 950 / 470 3.00 / 1.15 1.10 / 0.18 955 6.42 3.71 1.50 970 / 470 4.60 / 1.90 1.50 / 0.25 955 9.30 5.30 2.20 940 / 470 5.60 / 2.20 2.20 / 0.37 700 2.77 1.60 0.37 695 3.53 2.04 0.55 705 4.68 2.70 0.75 1445 10.96 6.33 3.00 1430 / 710 6.50 / 2.30 3.00 / 0.60 1440 14.10 8.12 4.00 1430 / 710 8.20 / 2.90 4.00 / 0.80 1440 11.60 6.72 5.50 1450 / 720 11.80 / 3.80 5.50 / 1.10 1455 14.20 8.20 7.50 1460 / 725 15.30 / 5.40 7.50 / 1.50 955 6.42 3.71 1.50 970 / 470 4.60 / 1.90 1.50 / 0.25 955 9.30 5.30 2.20 940 / 470 5.60 / 2.20 2.20 / 0.37 960 12.70 7.30 3.00 960 / 480 9.00 / 3.50 3.00 / 0.55 705 4.68 2.70 0.75 705 5.63 3.25 1.10 705 7.10 4.10 1.50 705 9.53 5.50 2.20 1440 11.60 6.72 5.50 1450 / 720 11.80 / 3.80 5.50 / 1.10 1455 14.20 8.20 7.50 1460 / 725 15.30 / 5.40 7.50 / 1.50 1460 20.20 11.60 11.00 1470 / 725 23.20 / 8.70 11.00 / 2.80 1460 27.50 15.90 15.00 1460 / 725 31.72 / 11.75 15.00 / 3.80 955 9.30 5.30 2.20 940 / 470 5.60 / 2.20 2.20 / 0.37 960 12.70 7.30 3.00 960 / 480 9.00 / 3.50 3.00 / 0.55 960 16.50 9.46 4.00 970 / 480 11.00 / 4.00 4.00 / 0.65 720 6.32 3.65 1.10 705 7.10 4.10 1.50 705 9.53 5.50 2.20 705 12.82 7.40 3.00 Maximum airflow (m3/h) 19600/9800 21100 21100/10550 23950 24150/12075 29400 29550/14775 15150 15150 17250 17150/8575 20950 20950/10475 28000 28000/14000 32700 32700/16350 37200 37200/18600 20600 20600/10300 24250 24250/12125 28000 28000/14000 32500 32500/16250 16600 19600 22150 37750 37750/18875 41850 41850/20925 47000 47000/23500 53000 53000/26500 30000 30000/15000 35000 35000/17500 40000 40000/20000 22400 24150 26300 30150 52500 52500/26250 58500 58500/29250 68000 68000/34000 71850 72450/36225 40500 40500/20250 46950 46950/23475 52000 52000/26000 32500 33850 35150 37800 Sound Approx. weight pressure level (Kg) dB(A) 75 / 60 76 76 / 61 78 78 / 63 79 79 / 64 65 65 66 66 / 51 67 67 / 52 79 79 / 64 80 80 / 65 81 81 / 66 69 69 / 54 70 70 / 55 71 71 / 56 72 72 / 57 67 68 69 84 84 / 69 86 86 / 71 88 88 / 73 89 89 / 74 75 75 / 60 76 76 / 61 77 77 / 62 69 70 71 72 89 89 / 74 90 90 / 75 91 91 / 76 92 92 / 77 80 80 / 65 81 81 / 66 82 82 / 67 74 75 75 76 75.8 79.8 79.5 89.3 86.3 91.3 89.7 73.2 73.2 80.3 79.3 82.3 81.3 97.3 94.3 99.3 97.7 104.2 110.2 88.3 87.3 90.3 89.3 96.3 106.2 101.2 106.2 87.3 89.3 94.3 123.2 121.6 128.1 134.1 143.5 153.5 154.5 158.5 120.2 130.1 125.1 130.1 148.5 147.5 118.2 121.2 132.1 158.5 152.1 162.1 163.1 167.1 185.7 185.7 204.7 200.7 133.0 138.0 157.1 156.1 165.1 161.1 128.3 140.0 167.1 175.1 39 CJHCH Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at an equivalent distance of twice the fan’s span plus the impeller’s diameter, with a minimum of 1.5 m. Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. Model 56-4-0,75 56-4-1 56-8-1 (2v) 56-4-1,5 56-8-1,5 (2v) 56-4-2 02/08/1956 (2v) 56-6-0,33 56-6-0,5 56-6-0,75 63-4-1 01/08/1963 (2v) 63-4-1,5 63-8-1,5 (2v) 63-4-2 02/08/1963 (2v) 63-4-3 03/08/1963 (2v) 63-4-4 04/08/1963 (2v) 63-6-0,5 63-6-0,75 63-6-1 01/12/1963 (2v) 71-4-1,5 71-8-1,5 (2v) 71-4-2 02/08/1971 (2v) 71-4-3 03/08/1971 (2v) 71-4-4 04/08/1971 (2v) 71-6-0,75 71-6-1 01/12/1971 (2v) 71-6-1,5 71-12-1,5 (2v) 80-4-3 03/08/1980 (2v) 80-4-4 04/08/1980 (2v) 80-4-5,5 80-8-5,5 (2v) 80-6-1 01/12/1980 (2v) 63 44 45 30 46 31 47 32 34 34 35 47 32 48 33 49 34 50 35 51 36 39 40 41 26 52 37 53 38 55 40 56 41 42 43 28 44 29 56 41 57 42 58 43 46 31 125 250500 1000200040008000 64 72 77 79 76 69 58 65 73 78 80 77 70 59 50 58 63 65 62 55 44 66 74 79 81 78 71 60 51 59 64 66 63 56 45 67 75 80 82 79 72 61 52 60 65 67 64 57 46 54 62 67 69 66 59 48 54 62 67 69 66 59 48 55 63 68 70 67 60 49 67 75 80 82 79 72 61 52 60 65 67 64 57 46 68 76 81 83 80 73 62 53 61 66 68 65 58 47 69 77 82 84 81 74 63 54 62 67 69 66 59 48 70 78 83 85 82 75 64 55 63 68 70 67 60 49 71 79 84 86 83 76 65 56 64 69 71 68 61 50 59 67 72 74 71 64 53 60 68 73 75 72 65 54 61 69 74 76 73 66 55 46 54 59 61 58 51 40 72 80 85 87 84 77 66 57 65 70 72 69 62 51 73 81 86 88 85 78 67 58 66 71 73 70 63 52 75 83 88 90 87 80 69 60 68 73 75 72 65 54 76 84 89 91 88 81 70 61 69 74 76 73 66 55 62 70 75 77 74 67 56 63 71 76 78 75 68 57 48 56 61 63 60 53 42 64 72 77 79 76 69 58 49 57 62 64 61 54 43 76 84 89 91 88 81 70 61 69 74 76 73 66 55 77 85 90 92 89 82 71 62 70 75 77 74 67 56 78 86 91 93 90 83 72 63 71 76 78 75 68 57 66 74 79 81 78 71 60 51 59 64 66 63 56 45 Model 80-6-1,5 80-12-1,5 (2v) 80-6-2 02/12/1980 (2v) 80-6-3 03/12/1980 (2v) 80-8-0,5 80-8-0,75 80-8-1 90-4-4 04/08/1990 (2v) 90-4-5,5 90-8-5,5 (2v) 90-4-7,5 90-8-7,5 (2v) 90-4-10 10/08/1990 (2v) 90-6-2 02/12/1990 (2v) 90-6-3 03/12/1990 (2v) 90-6-4 04/12/1990 (2v) 90-8-1 90-8-1,5 90-8-2 90-8-3 100-4-7,5 100-8-7,5 (2v) 100-4-10 100-8-10 (2v) 100-4-15 100-8-15 (2v) 100-4-20 100-8-20 (2v) 100-6-3 100-12-3 (2v) 100-6-4 100-12-4 (2v) 100-6-5,5 100-12-5,5 (2v) 100-8-1,5 100-8-2 100-8-3 100-8-4 63 47 32 48 33 49 34 44 45 46 62 47 64 49 66 51 67 52 53 38 54 39 55 40 47 48 49 50 69 54 70 55 71 56 72 57 60 45 61 46 62 47 54 55 55 56 125 250500 1000200040008000 67 75 80 82 79 72 61 52 60 65 67 64 57 46 68 76 81 83 80 73 62 53 61 66 68 65 58 47 69 77 82 84 81 74 63 54 62 67 69 66 59 48 64 72 77 79 76 69 58 65 73 78 80 77 70 59 66 74 79 81 78 71 60 83 90 95 98 94 87 76 68 75 80 83 79 72 61 85 92 97 100 96 89 78 70 77 82 85 81 74 63 87 94 99 102 98 91 80 72 79 84 87 83 76 65 88 95 100 103 99 92 81 73 80 85 88 84 77 66 74 81 86 89 85 78 67 59 66 71 74 70 63 52 75 82 87 90 86 79 68 60 67 72 75 71 64 53 76 83 88 91 87 80 69 61 68 73 76 72 65 54 68 75 80 83 79 72 61 69 76 81 84 80 73 62 70 77 82 85 81 74 63 71 78 83 86 82 75 64 89 97 102 104 101 94 83 74 82 87 89 86 79 68 90 98 103 105 102 95 84 75 83 88 90 87 80 69 91 99 104 106 103 96 85 76 84 89 91 88 81 70 92 100 105 107 104 97 86 77 85 90 92 89 82 71 80 88 93 95 92 85 74 65 73 78 80 77 70 59 81 89 94 96 93 86 75 66 74 79 81 78 71 60 82 90 95 97 94 87 76 67 75 80 82 79 72 61 74 82 87 89 86 79 68 75 83 88 90 87 80 69 75 83 88 90 87 80 69 76 84 89 91 88 81 70 Dimensions in mm Model ACD1 CJHCH-56/63 825 550 690 CJHCH-71/80 1000 650 850 CJHCH-90/100 1200 750 1050 Characteristic curves and efficiency data See curves and efficiency data HCH-HCT series Accessories See accessories section. INT 40 RM AR C2V RFT/ RFM PANELS PL P RI RT S SI HTP HTP Cased high-pressure axial fans Robust cased axial high-pressure fans, especially designed for mining installations with large losses of load Fan: • Sheet steel thick long casing • Motor base welded to the casing • Guidelines for high aerodynamic performance for pressure gain • Optimum surface protection by means of high-quality steel. • High-performance, cast aluminium impeller. • Airflow direction from impeller to motor • Electrical connection in outside terminal board. Motor: • Single-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors with ball bearings, IP-55 protection • Three-phase 230/400V.-50Hz. (up to 5.5CV.) and 400/690V.-50Hz. (power over 5.5CV.) • Working temperature: -20ºC +70ºC Finish: • High-protection, anti-corrosion steel, specially primed and high-quality paint for corrosive environments. On request: • Standardised IP-55 motors, ATEX motors and two speeds • Stainless steel or iron impellers • Made entirely from stainless steel. • Hot-rolled galvanised steel construction High pressure impeller Order code HTP Cased high-pressure axial fans 63 2T Impeller diameter in cm. 10 Number of motor poles 2=2950 r/min. 50 Hz 4=1450 r/min. 50 Hz 20º T=Three-phase Motor power (CV) PV Angle of inclination of the blades PV=Distributor Technical characteristics Model HTP-50-2T-4 HTP-50-2T-5.5 HTP-56-2T-5.5 HTP-56-2T-10 HTP-63-2T-10 HTP-63-2T-15 HTP-63-2T-20 HTP-63-2T-25 HTP-63-2T-30 HTP-63-4T-1.5 HTP-63-4T-2 HTP-63-4T-3 HTP-63-4T-4 HTP-71-2T-15 HTP-71-2T-20 HTP-71-2T-25 HTP-71-2T-30 HTP-71-2T-40 HTP-71-4T-2 HTP-71-4T-3 HTP-71-4T-4 Speed (r/min) 2900 2870 2870 2870 2870 2940 2935 2930 2935 1400 1430 1445 1445 2940 2935 2930 2935 2940 1445 1445 1445 Maximum admissible current (A) 230V 400V 690V 10.18 13.60 13.60 - - - - - - 4.03 5.96 8.36 10.96 - - - - - 8.36 8.36 10.96 5.88 7.82 7.82 14.50 14.50 20.30 27.40 32.40 38.00 2.32 3.44 4.83 6.33 20.30 27.40 32.40 38.00 50.00 4.83 4.83 6.33 - - - 8.41 8.41 11.70 15.90 18.70 22.00 - - - - 11.70 15.90 18.70 22.00 29.00 - - - Installed power (kW) 3.00 4.00 4.00 7.50 7.50 11.00 15.00 18.50 22.00 1.10 1.50 2.20 3.00 11.00 15.00 18.50 22.00 30.00 2.20 2.20 3.00 Maximum airflow (m3/h) 13850 16450 18050 25500 23850 29400 34400 37200 39800 12850 15650 18600 19900 32850 39250 43450 45500 52550 17500 20650 23950 Approx. weight (Kg) 49 65 69 147 132 167 181 199 208 92 93 101 104 184 198 216 225 303 110 118 121 NPS dB(A) 82 83 88 89 94 94 97 98 99 79 79 83 84 93 95 95 95 98 83 83 84 41 HTP Technical characteristics Model Speed (r/min) HTP-71-4T-5.5 HTP-71-4T-7.5 HTP-80-4T-4 HTP-80-4T-5.5 HTP-80-4T-7.5 HTP-80-4T-10 HTP-80-4T-15 HTP-90-4T-7.5 HTP-90-4T-10 HTP-90-4T-15 HTP-90-4T-20 HTP-90-4T-25 HTP-90-4T-30 HTP-100-4T-15 HTP-100-4T-20 HTP-100-4T-25 HTP-100-4T-30 HTP-100-4T-40 HTP-125-4T-40 HTP-125-4T-50 HTP-125-4T-60 HTP-125-4T-75 HTP-125-4T-100 HTP-125-4T-125 1440 1440 1445 1440 1440 1400 1460 1440 1455 1460 1460 1460 1465 1460 1460 1460 1465 1465 1465 1470 1470 1475 1480 1480 Maximum admissible current (A) 230V 400V 690V 14.10 - 10.96 14.10 - - - - - - - - - - - - - - - - - - - - 8.12 11.60 6.33 8.12 11.60 2.32 20.20 11.60 14.20 20.20 27.50 35.00 42.00 20.20 27.50 35.00 42.00 55.00 55.00 69.20 81.00 99.00 133.00 159.00 - 6.72 - - 6.72 1.34 11.60 6.72 8.20 11.60 15.90 20.00 24.00 11.60 15.90 20.00 24.00 32.00 32.00 40.10 47.00 57.00 77.00 92.00 Installed power (kW) 4.00 5.50 3.00 4.00 5.50 1.10 11.00 5.50 7.50 11.00 15.00 18.50 22.00 11.00 15.00 18.50 22.00 30.00 30.00 37.00 45.00 55.00 75.00 90.00 Maximum airflow (m3/h) 27400 31700 19300 22850 28000 31500 40000 27450 32500 42200 50050 54550 61750 46100 56300 59900 69900 80500 81000 96800 105050 127800 147350 156800 Approx. weight (Kg) NPS dB(A) 127 141 146 152 166 177 217 196 207 247 266 294 311 282 301 329 346 401 503 525 558 599 674 703 87 90 86 86 86 87 91 90 90 90 94 95 97 93 93 93 96 98 100 100 100 100 104 105 Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at an equivalent distance of twice the fan’s span plus the impeller’s diameter, with a minimum of 1.5 m. Model HTP-50-2T-4 HTP-50-2T-5.5 HTP-56-2T-5.5 HTP-56-2T-10 HTP-63-2T-10 HTP-63-2T-15 HTP-63-2T-20 HTP-63-2T-25 HTP-63-2T-30 HTP-63-4T-1.5 HTP-63-4T-2 HTP-63-4T-3 HTP-63-4T-4 HTP-71-2T-15 HTP-71-2T-20 HTP-71-2T-25 HTP-71-2T-30 HTP-71-2T-40 HTP-71-4T-2 HTP-71-4T-3 HTP-71-4T-4 HTP-71-4T-5.5 HTP-71-4T-7.5 LpdB(A) 80 81 86 87 94 94 97 98 99 79 79 83 84 93 95 95 95 98 83 83 84 87 90 63 57 58 63 64 70 70 73 74 75 55 55 59 60 65 67 67 67 70 55 55 56 59 62 125 77 78 83 84 82 82 85 86 87 67 67 71 72 83 85 85 85 88 73 72 74 77 80 250 85 86 91 92 92 92 95 96 97 77 77 81 82 93 95 95 95 98 83 83 84 87 90 Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. 500 1000 20004000 90 92 89 82 91 93 90 83 96 98 95 88 97 99 96 89 104 105 104 99 104 105 104 99 107 108 107 102 108 109 108 103 109 110 109 104 89 90 89 84 89 90 89 84 93 94 93 88 94 95 94 89 102 104 103 100 104 106 105 102 104 106 105 102 104 106 105 102 107 109 108 105 92 93 93 90 92 93 93 90 94 95 95 91 97 98 98 95 100 101 101 97 8000 71 72 77 78 91 91 94 95 96 76 76 80 81 93 95 95 95 98 83 83 85 88 91 Model 63 125 250500 1000200040008000 HTP-80-4T-4 86 58 75 86 95 96 96 93 86 HTP-80-4T-5.5 86 58 76 86 95 96 96 93 86 HTP-80-4T-7.5 86 58 76 86 95 96 96 93 86 HTP-80-4T-10 87 59 77 87 97 98 98 94 88 HTP-80-4T-15 91 63 81 91 101 102 102 99 92 HTP-90-4T-7.5 90 62 79 90 99 100 100 97 90 HTP-90-4T-10 90 62 80 90 99 100 100 97 90 HTP-90-4T-15 90 62 80 90 100 101 101 98 91 HTP-90-4T-20 94 66 83 94 103 104 104 101 94 HTP-90-4T-25 95 67 85 95 104 105 105 102 95 HTP-90-4T-30 97 69 87 97 107 108 108 104 98 HTP-100-4T-15 93 65 83 93 102 103 103 100 93 HTP-100-4T-20 93 65 82 93 102 103 103 100 93 HTP-100-4T-25 93 65 83 93 102 103 103 100 93 HTP-100-4T-30 96 67 85 96 105 106 106 103 96 HTP-100-4T-40 98 70 88 98 107 108 108 105 98 HTP-125-4T-40 100 72 89 100 109 110 110 107 100 HTP-125-4T-50 100 72 90 100 109 110 110 107 100 HTP-125-4T-60 100 72 89 100 109 110 110 107 100 HTP-125-4T-75 100 72 90 100 110 111 111 108 101 HTP-125-4T-100 104 76 93 104 113 114 114 111 104 HTP-125-4T-125 105 77 95 105 114 115 115 112 105 Dimensions in mm 42 Model Power ØA HTP-50-2T 600 HTP-56-2T 660 HTP-63-2T 730 HTP-63-4T 730 HTP-71-2T 810 HTP-71-4T 810 HTP-80-4T 4 / 5’5 900 HTP-80-4T 7’5 / 10 / 15 900 HTP-90-4T 7’5 / 10 1015 HTP-90-4T 15 / 20 / 25 / 30 1015 HTP-100-4T 15 / 20 1115 HTP-100-4T 25 / 30 / 40 1115 HTP -12540 / 50 / 60 / 75 20x18º HTP -125100 / 1251365 ØB ØD E 560 514 - 620 560 - 690 640 650 690 640 340 770 710 700 770 710 420 860 800 360 860 800 550 970 900 420 970 900 650 1070 1000 550 1070 1000 700 1365 1320 1250 E1 - - 220 220 240 240 240 240 250 250 270 270 800 1320 1250 300 1250 950 C ØJ 500 12 500 12 870 12 560 12 940 12 660 12 600 12 790 12 670 15 900 15 820 15 970 15 3001100 15 N 12x30º 12x30º 12x30º 12x30º 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 15 20x18º HTP EXAMPLE OF SELECTION Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. HTP-63-4T Initial data • Working point: • Airflow: 12,500 m3/h • Loss of load: 7,5 mmH2O Steps for the selection of equipment On the pressure graph: • 1. Mark the working point, defined by the airflow (12,500 m3/h) and the loss of load (7.5 mmH2O). • 2. Select the curve of the equipment which is closest above the working point. In our case, a curve with a blade angle of 22º is obtained. On the power graph: • 3. Mark the working point, defined by the airflow (12,500 m3/h) and the selected blade angle (22º). • 4. Read the absorbed power on the power axis on the left. Pa= 560 W at the working point. • 5. Look for the straight red line which is closest to the working point above. On the right-hand side of the graph, the value of the installed motor power is obtained. In our case, this is 0.75 kW or 1 CV Recommended motor power kW (CV) Absorbed power EXAMPLE OF ORDER CODE HTP Cased high-pressure axial fans 63 4T Impeller diameter Number of motor poles in cm. 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz T=Three-phase M=Single-phase 1 Motor power (CV) 22º Angle of inclination of the blades 43 HTP Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. HTP-50-2T Absorbed power Available features best efficiency point (BEP ) at the end of the series. 44 Recommended motor power kW (CV) HTP Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. HTP-56-2T Absorbed power Recommended motor power kW (CV) Available features best efficiency point (BEP ) at the end of the series. 45 HTP Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. HTP-63-2T Absorbed power Available features best efficiency point (BEP ) at the end of the series. 46 Recommended motor power kW (CV) HTP Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. HTP-63-4T Absorbed power Recommended motor power kW (CV) Available features best efficiency point (BEP ) at the end of the series. 47 HTP Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. HTP-71-2T Absorbed power Available features best efficiency point (BEP ) at the end of the series. 48 Recommended motor power kW (CV) HTP Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. HTP-71-4T Absorbed power Recommended motor power kW (CV) Available features best efficiency point (BEP ) at the end of the series. 49 HTP Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. HTP-80-4T Absorbed power Available features best efficiency point (BEP ) at the end of the series. 50 Recommended motor power kW (CV) HTP Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. HTP-90-4T Absorbed power Recommended motor power kW (CV) Available features best efficiency point (BEP ) at the end of the series. 51 HTP Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. HTP-100-4T Absorbed power Available features best efficiency point (BEP ) at the end of the series. 52 Recommended motor power kW (CV) HTP Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. HTP-125-4T Absorbed power Recommended motor power kW (CV) Available features best efficiency point (BEP ) at the end of the series. 53 HTP Erp. BEP (best efficiency point) characteristics ∢ [º] PN MC EC VSD Angle of inclination of the blades in degreess Motor's nominal power in kW Measurement category Efficiency category S Static T Total Variable-speed drive SR Specific relationship ηe[%] Efficiency N Degree of efficiency [kW] Electrical power [m3/h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed HTP-50-2T [mmH2O] [RPM] ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] 8 10 12 14 16 18 20 22 24 26 28 30 2.2 2.2 3 3 4 4 4 5.5 5.5 5.5 7.5 7.5 C C C C C C C C B B B B S S S S S S S S T T T T NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.00 1.01 1.01 1.01 40.3% 39.0% 38.3% 37.3% 35.6% 34.0% 33.5% 34.7% 49.6% 49.5% 48.9% 48.8% 45.0 43.2 42.1 40.7 38.7 36.7 36.0 37.0 51.8 51.4 50.4 50.0 1.797 2.167 2.485 2.832 3.255 3.700 4.023 4.363 4.627 5.143 5.725 6.436 6731 7180 7884 8541 8962 9368 9537 10176 16615 17229 18386 19548 39.48 43.23 44.29 45.39 47.55 49.31 51.91 54.63 50.79 54.30 55.89 59.00 2888 2864 2914 2901 2914 2902 2893 2936 2932 2924 2938 2930 HTP-56-2T ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 2.2 3 3 4 5.5 5.5 5.5 7.5 7.5 7.5 11 11 11 15 15 15 C C C C C C C B B B B B B B B B S S S S S S S T T T T T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 60.5% 54.8% 50.9% 49.1% 48.1% 45.8% 44.5% 60.9% 60.3% 60.1% 57.1% 54.4% 53.0% 51.8% 50.9% 50.2% 65.0 58.6 54.2 52.0 50.6 47.9 46.3 62.4 61.6 61.1 57.8 54.7 53.0 51.8 50.8 50.1 1.914 2.491 3.018 3.526 4.046 4.663 5.246 5.756 6.362 6.944 7.856 8.890 9.914 10.932 11.965 13.018 10060 10410 11389 11508 13418 14275 15266 18179 19341 20914 21588 22868 25263 26289 27557 28272 42.26 48.18 49.56 55.31 53.26 54.95 56.14 70.82 72.87 73.33 76.35 77.67 76.40 79.08 81.16 84.97 2880 2913 2895 2907 2940 2931 2923 2937 2931 2925 2957 2952 2946 2953 2948 2944 HTP-63-2T ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 54 7.5 7.5 7.5 11 11 11 15 15 15 18.5 18.5 22 22 C C C C C C C C C C C C C S S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.02 1.02 1.02 1.02 1.02 1.02 63.1% 61.7% 60.8% 61.7% 61.1% 59.5% 59.7% 58.8% 58.1% 57.5% 54.9% 52.7% 50.8% 64.6 62.9 61.7 62.3 61.4 59.6 59.7 58.7 57.9 57.2 54.6 52.3 50.3 5.696 6.567 7.428 8.081 9.179 10.320 11.390 12.321 13.671 14.909 16.763 18.566 20.405 13562 14654 15642 16570 17063 18242 20352 19247 21081 23032 23740 24546 25369 97.33 101.55 106.10 110.56 120.77 123.71 122.82 138.18 138.33 136.65 142.38 146.29 150.12 2940 2930 2921 2957 2951 2945 2951 2948 2942 2956 2950 2957 2953 HTP Erp. BEP (best efficiency point) characteristics HTP-63-4T ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 0.75 1.1 1.1 1.1 1.5 1.5 1.5 2.2 2.2 2.2 2.2 3 3 3 4 4 C C C C C C C C C C C C C C C C S S S S S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 56.9% 57.0% 56.2% 55.8% 56.1% 54.6% 54.3% 54.4% 53.7% 52.8% 50.4% 48.9% 47.2% 43.9% 41.3% 38.2% 63.9 63.7 62.5 61.8 61.8 60.0 59.4 59.3 58.4 57.2 54.5 52.7 50.7 47.1 44.3 41.0 0.790 0.888 1.005 1.118 1.251 1.407 1.566 1.664 1.846 2.029 2.281 2.500 2.747 3.045 3.334 3.590 6781 7327 7821 8285 8532 9121 10176 9623 10541 11516 11870 12273 12685 13549 14297 15407 24.33 25.39 26.53 27.64 30.19 30.93 30.70 34.55 34.58 34.16 35.60 36.57 37.53 36.21 35.38 32.71 1424 1460 1455 1450 1458 1453 1448 1458 1454 1449 1443 1443 1437 1430 1457 1453 HTP-71-2T ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 11 15 15 15 18.5 18.5 22 22 30 30 30 30 C C C C C C C C C C C C S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.01 1.01 1.01 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 65.9% 65.0% 63.9% 63.6% 62.7% 61.4% 62.9% 60.8% 58.0% 56.8% 56.1% 54.3% 66.0 65.0 63.8 63.4 62.4 61.1 62.5 60.3 57.4 56.2 55.4 53.5 10.153 11.308 12.610 13.873 15.552 17.341 18.923 21.346 24.236 26.558 28.110 30.493 20358 21567 22971 23869 26171 29550 28934 31510 34832 37324 37671 38513 120.78 125.28 128.86 135.83 136.80 132.46 151.17 151.41 148.18 148.58 153.78 157.94 2946 2952 2946 2941 2954 2948 2956 2951 2966 2963 2961 2958 HTP-71-4T ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 1.5 1.5 2.2 2.2 2.2 3 3 3 4 4 4 4 5.5 5.5 5.5 7.5 C C C C C C C C C C C C C C C C S S S S S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 60.5% 59.1% 59.1% 58.9% 57.6% 57.2% 58.4% 56.5% 54.1% 53.0% 52.4% 50.7% 50.6% 48.4% 45.9% 44.5% 65.9 64.2 64.0 63.5 61.8 61.2 62.2 59.9 57.2 55.9 55.1 53.2 53.0 50.5 47.7 46.1 1.384 1.555 1.703 1.874 2.117 2.330 2.548 2.874 3.246 3.557 3.765 4.084 4.276 4.696 5.196 5.592 10179 10783 11486 11935 13085 14775 14467 15755 17416 18662 18836 19256 19555 20811 22143 23383 30.19 31.32 32.22 33.96 34.20 33.11 37.79 37.85 37.04 37.15 38.44 39.49 40.65 40.15 39.56 39.07 1454 1448 1457 1453 1447 1447 1442 1434 1458 1454 1451 1447 1473 1470 1467 1470 HTP-80-4T ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 3 4 4 5.5 5.5 5.5 7.5 7.5 7.5 11 11 11 11 11 C C C C C C C C C C C C C C S S S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 45.9% 46.8% 47.5% 49.9% 50.3% 49.3% 49.1% 47.9% 47.2% 46.7% 45.1% 43.8% 43.0% 42.7% 49.1 49.7 50.1 52.2 52.3 51.0 50.6 49.1 48.1 47.4 45.6 44.1 43.2 42.7 3.042 3.466 3.949 4.334 4.871 5.411 5.909 6.605 7.294 7.845 8.461 9.108 9.553 10.208 12859 14380 15604 16927 18604 19531 20646 21619 22603 23377 23934 24700 24657 25847 39.86 41.40 44.16 46.89 48.40 50.19 51.65 53.75 55.93 57.56 58.57 59.31 61.26 61.88 1431 1455 1449 1472 1469 1465 1468 1465 1461 1481 1479 1478 1476 1475 55 HTP Erp. BEP (best efficiency point) characteristics HTP-90-4T ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 5.5 7.5 7.5 11 11 11 11 15 15 15 18.5 18.5 18.5 18.5 22 C C C C C C C C C C C C C C C S S S S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 47.2% 48.0% 48.8% 51.0% 51.5% 50.5% 49.8% 49.0% 48.2% 47.1% 45.8% 44.5% 43.7% 43.3% 43.3% 49.0 49.4 49.8 51.8 52.0 50.7 49.8 48.9 48.1 46.9 45.6 44.2 43.4 42.9 42.9 5.326 6.084 6.933 7.629 8.574 9.523 10.506 11.640 12.856 14.013 15.014 16.162 16.952 18.115 19.132 18308 20475 22217 24102 26488 27809 29396 30782 32182 33285 34077 35169 35107 36802 38497 50.44 52.40 55.88 59.35 61.25 63.53 65.37 68.03 70.79 72.85 74.13 75.07 77.54 78.32 79.11 1466 1468 1463 1481 1479 1477 1474 1475 1473 1470 1474 1472 1471 1469 1472 HTP-100-4T ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 11 11 15 15 15 18.5 18.5 22 22 30 30 30 C C C C C C C C C C C C S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 56.7% 58.3% 57.3% 56.1% 53.8% 51.5% 49.4% 48.7% 47.8% 46.9% 44.8% 43.4% 57.0 58.4 57.3 56.0 53.6 51.2 49.0 48.3 47.4 46.3 44.1 42.7 8.918 10.164 11.460 12.885 14.504 16.130 17.884 19.092 20.796 22.433 24.785 26.720 27276 30265 33345 37128 39472 41007 42917 45347 49344 51228 54000 54700 68.06 71.90 72.39 71.54 72.67 74.43 75.60 75.35 74.08 75.43 75.47 77.79 1478 1475 1476 1473 1469 1472 1469 1472 1469 1479 1477 1475 HTP-125-4T ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 30 37 37 45 45 55 55 75 75 75 90 90 C C C C C C C C C C C C S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.02 1.02 1.02 1.02 43.4% 46.4% 48.5% 50.8% 52.3% 53.6% 54.6% 54.6% 54.7% 52.1% 47.9% 44.6% 42.7 45.6 47.6 49.9 51.3 52.5 53.4 53.3 53.4 50.8 46.5 43.0 27.761 31.556 34.890 38.003 41.886 46.180 50.747 55.048 58.457 64.144 71.971 80.000 50255 53478 58117 62762 69294 76423 83496 83497 85592 89569 94123 98798 88.10 100.67 106.95 113.08 116.17 118.93 121.90 132.17 137.26 137.11 134.68 132.55 1474 1480 1478 1480 1478 1480 1478 1490 1489 1488 1489 1487 SI PV Accessories See accessories section. INT 56 AR RFT/ RFM PANELS PL P PT/H RT BTUB BAC PS S HGT HGTX HGT HGTX HGT: Large long cased axial fans with direct drive motor HGTX: Large long cased axial fans with external motor Long cased axial fans, supplied with 3, 6 or 9 blade aluminium impellers with different slope angles. Fan: • Airflow direction from motor to impeller • Impellers made from cast aluminium supplied with 3, 6 or 9 blades with adjustable slope angles. • Sheet steel tubular casing. • HGT: THe standard version is short casing. The long-casing version is equipped with an inspection hatch. • HGTX: The long-casing version is equipped with an inspection hatch. Motor: • Tree-phase IE2 motors • Class F motors, with bearings, IP55 protection. • Three-phase 230/400V.-50Hz. (up to 5.5CV.) and 400/690V.-50Hz. (power over 5.5CV.) • Working temperature: -25ºC. + 50ºC. (HGT), -25ºC. + 120ºC. (HGTX) HGT Finish: • Anticorrosive finish in polyester resin, polymerised at 190ºC, after alkaline HGTX degreasing and phosphate-free pre-treatment. On request: • Airflow direction from impeller to motor. • 100% reversible impellers • Special windings for different voltages. • ATEX certification, Category 2 • HGT: Long-casing fans with inspection hatch • Two-speed motors Order code HGT HGT: Large long cased axial fans with direct drive motor HGTX: Large long cased axial fans with external motor 125 4T Impeller diameter Number of motor poles in cm. 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz 6-20 T=Three-phase 10º PV Number Motor power Angle PV=Distributor of blades: (CV) of inclination 3 blades of the blades 6 blades 9 blades Technical characteristics Model HGT-125-4T/3-10 HGTX-125-4T/3-10 HGT-125-4T/3-15 HGTX-125-4T/3-15 HGT-125-4T/3-20 HGTX-125-4T/3-20 HGT-125-4T/3-25 HGTX-125-4T/3-25 HGT-125-4T/3-30 HGTX-125-4T/3-30 HGT-125-4T/3-40 HGTX-125-4T/3-40 HGT-125-4T/3-50 HGTX-125-4T/3-50 HGT-125-4T/3-60 HGTX-125-4T/3-60 HGT-125-4T/6-20 HGTX-125-4T/6-20 HGT-125-4T/6-25 HGTX-125-4T/6-25 HGT-125-4T/6-30 HGTX-125-4T/6-30 HGT-125-4T/6-40 HGTX-125-4T/6-40 HGT-125-4T/6-50 HGTX-125-4T/6-50 HGT-125-4T/6-60 HGTX-125-4T/6-60 HGT-125-4T/6-75 HGTX-125-4T/6-75 HGT-125-4T/6-100 HGTX-125-4T/6-100 HGT-125-4T/9-25 HGTX-125-4T/9-25 HGT-125-4T/9-30 HGTX-125-4T/9-30 Speed Maximum admissible current (A) (r/min) 230V 400V 690V 1455 14.10 8.14 1455 21.20 12.24 1465 29.80 17.21 1470 35.60 20.55 1465 40.10 23.15 1475 56.30 32.50 1470 69.20 39.95 1470 81.41 47.00 1465 29.80 17.21 1470 35.60 20.55 1465 40.10 23.15 1475 56.30 32.50 1470 69.20 39.95 1470 81.41 47.00 1475 98.73 57.00 1480 133.37 77.00 1470 35.60 20.55 1465 40.10 23.15 Installed power (kW) 7.50 11.00 15.00 18.50 22.00 30.00 37.00 45.00 15.00 18.50 22.00 30.00 37.00 45.00 55.00 75.00 18.50 22.00 Maximum Sound Approx. weight (Kg) airflow pressure level HGT HGTX (m3/h) dB(A) Long Short 58150 88 211 178 342 77450 89 249 221 369 91400 91 268 240 388 98350 91 331 288 418 110500 92 348 305 435 120850 93 440 397 529 129000 94 474 418 545 140000 95 489 433 560 78300 89 277 249 397 92000 90 340 297 427 98100 90 357 314 444 117000 92 449 405 538 123700 93 483 427 554 136000 94 498 442 569 148000 95 549 499 635 161000 96 598 548 684 79750 88 349 306 436 97000 89 366 323 453 57 HGT HGTX Technical characteristics Model HGT-125-4T/9-40 HGTX-125-4T/9-40 HGT-125-4T/9-50 HGTX-125-4T/9-50 HGT-125-4T/9-60 HGTX-125-4T/9-60 HGT-125-4T/9-75 HGTX-125-4T/9-75 HGT-125-4T/9-100 HGTX-125-4T/9-100 HGT-125-6T/3-4 HGTX-125-6T/3-4 HGT-125-6T/3-5.5 HGTX-125-6T/3-5.5 HGT-125-6T/3-7.5 HGTX-125-6T/3-7.5 HGT-125-6T/3-10 HGTX-125-6T/3-10 HGT-125-6T/3-15 HGTX-125-6T/3-15 HGT-125-6T/3-20 HGTX-125-6T/3-20 HGT-125-6T/6-5.5 HGTX-125-6T/6-5.5 HGT-125-6T/6-7.5 HGTX-125-6T/6-7.5 HGT-125-6T/6-10 HGTX-125-6T/6-10 HGT-125-6T/6-15 HGTX-125-6T/6-15 HGT-125-6T/6-20 HGTX-125-6T/6-20 HGT-125-6T/6-25 HGTX-125-6T/6-25 HGT-125-6T/9-10 HGTX-125-6T/9-10 HGT-125-6T/9-15 HGTX-125-6T/9-15 HGT-125-6T/9-20 HGTX-125-6T/9-20 HGT-125-6T/9-25 HGTX-125-6T/9-25 HGT-125-6T/9-30 HGTX-125-6T/9-30 HGT-125-8T/3-3 HGTX-125-8T/3-3 HGT-125-8T/3-4 HGTX-125-8T/3-4 HGT-125-8T/3-5.5 HGTX-125-8T/3-5.5 HGT-125-8T/3-7.5 HGTX-125-8T/3-7.5 HGT-125-8T/6-3 HGTX-125-8T/6-3 HGT-125-8T/6-4 HGTX-125-8T/6-4 HGT-125-8T/6-5.5 HGTX-125-8T/6-5.5 HGT-125-8T/6-7.5 HGTX-125-8T/6-7.5 HGT-125-8T/6-10 HGTX-125-8T/6-10 HGT-125-8T/9-4 HGTX-125-8T/9-4 HGT-125-8T/9-5.5 HGTX-125-8T/9-5.5 HGT-125-8T/9-7.5 HGTX-125-8T/9-7.5 HGT-125-8T/9-10 HGTX-125-8T/9-10 HGT-125-8T/9-15 HGTX-125-8T/9-15 HGT-140-6T/3-4 HGT-140-6T/3-5.5 HGT-140-6T/3-7.5 HGT-140-6T/3-10 HGT-140-6T/3-15 HGT-140-6T/3-20 HGT-140-6T/6-5.5 HGT-140-6T/6-7.5 HGT-140-6T/6-10 HGT-140-6T/6-15 HGT-140-6T/6-20 HGT-140-6T/6-25 HGT-140-6T/6-30 HGT-140-6T/9-10 HGT-140-6T/9-15 HGT-140-6T/9-20 HGT-140-6T/9-25 HGT-140-6T/9-30 HGT-140-6T/9-40 HGT-140-6T/9-50 HGT-140-8T/3-3 HGT-140-8T/3-4 HGT-140-8T/3-5.5 HGT-140-8T/3-7.5 HGT-140-8T/3-10 HGT-140-8T/6-3 HGT-140-8T/6-4 58 Speed (r/min) Maximum admissible current (A) 230V 400V 690V 1475 1470 1470 1475 1480 960 12.70 960 16.50 975 965 965 970 960 16.50 975 965 965 970 970 965 965 970 970 970 705 9.53 705 12.82 710 16.11 725 705 9.53 705 12.82 710 16.11 725 725 705 12.82 710 16.11 725 725 725 960 12.70 960 16.50 975 965 965 970 960 16.50 975 965 965 970 970 970 965 965 970 970 970 973 975 705 9.53 705 12.82 710 16.11 725 725 705 9.53 705 12.82 56.30 32.50 69.20 39.95 81.41 47.00 98.73 57.00 133.37 77.00 7.33 9.53 11.50 6.64 15.20 8.78 22.60 13.05 27.90 16.11 9.53 11.50 6.64 15.20 8.78 22.60 13.05 27.90 16.11 34.64 20.00 15.20 8.78 22.60 13.05 27.90 16.11 34.64 20.00 41.57 24.00 5.50 7.40 9.30 12.70 7.33 5.50 7.40 9.30 12.70 7.33 17.00 9.81 7.40 9.30 12.70 7.33 17.00 9.81 21.70 12.53 7.33 9.53 11.50 6.64 15.20 8.78 22.60 13.05 27.90 16.11 9.53 11.50 6.64 15.20 8.78 22.60 13.05 27.90 16.11 34.64 20.00 41.57 24.00 15.20 8.78 22.60 13.05 27.90 16.11 34.64 20.00 41.57 24.00 53.69 31.00 65.82 38.00 5.50 7.40 9.30 12.70 7.33 17.00 9.81 5.50 7.40 Installed power (kW) 30.00 37.00 45.00 55.00 75.00 3.00 4.00 5.50 7.50 11.00 15.00 4.00 5.50 7.50 11.00 15.00 18.50 7.50 11.00 15.00 18.50 22.00 2.20 3.00 4.00 5.50 2.20 3.00 4.00 5.50 7.50 3.00 4.00 5.50 7.50 11.00 3.00 4.00 5.50 7.50 11.00 15.00 4.00 5.50 7.50 11.00 15.00 18.50 22.00 7.50 11.00 15.00 18.50 22.00 30.00 37.00 2.20 3.00 4.00 5.50 7.50 2.20 3.00 Maximum Sound Approx. weight (Kg) airflow pressure level HGT HGTX 3 (m /h) dB(A) Long Short 111200 118350 127000 142000 155000 46550 55300 64450 76400 87050 91700 51300 60300 72250 85450 92850 103000 68200 77550 92900 98700 104000 48800 54900 62100 69500 45700 51800 61500 67500 75500 48200 55200 67000 74750 80800 51000 56700 67900 80100 96900 106000 58000 66000 80700 96700 104000 115000 119000 70000 86000 97500 111000 118500 132000 139000 50000 57000 65400 77500 86000 47500 57600 91 93 94 95 99 79 80 81 83 84 85 77 77 79 81 82 84 78 81 84 85 87 71 71 73 75 69 71 72 73 75 70 73 75 76 79 82 83 84 85 86 88 82 84 85 86 87 88 89 84 86 87 88 89 91 92 78 78 79 81 82 78 79 458 492 507 558 607 204 209 217 262 276 358 218 226 271 285 367 409 280 294 376 418 438 209 216 249 262 218 225 258 271 301 234 267 280 310 372 251 258 266 320 334 414 268 276 330 344 423 466 486 339 353 433 475 495 561 623 258 265 307 320 350 268 275 414 436 451 508 557 171 176 184 234 248 315 185 193 243 257 324 365 252 266 333 374 394 176 183 221 234 185 192 230 243 273 201 239 252 282 329 214 221 229 281 295 364 231 239 291 305 374 417 437 300 314 383 427 447 499 568 221 228 268 281 311 231 238 547 563 578 644 693 335 340 348 382 396 445 349 357 391 405 454 498 400 414 463 507 527 340 347 369 382 349 356 378 391 421 365 387 400 430 459 HGT HGTX Technical characteristics Model HGT-140-8T/6-5.5 HGT-140-8T/6-7.5 HGT-140-8T/6-10 HGT-140-8T/6-15 HGT-140-8T/9-4 HGT-140-8T/9-5.5 HGT-140-8T/9-7.5 HGT-140-8T/9-10 HGT-140-8T/9-15 HGT-140-8T/9-20 HGT-160-6T/3-5.5 HGT-160-6T/3-7.5 HGT-160-6T/3-10 HGT-160-6T/3-15 HGT-160-6T/3-20 HGT-160-6T/3-25 HGT-160-6T/3-30 HGT-160-6T/6-10 HGT-160-6T/6-15 HGT-160-6T/6-20 HGT-160-6T/6-25 HGT-160-6T/6-30 HGT-160-6T/6-40 HGT-160-6T/6-50 HGT-160-6T/9-15 HGT-160-6T/9-20 HGT-160-6T/9-25 HGT-160-6T/9-30 HGT-160-6T/9-40 HGT-160-6T/9-50 HGT-160-6T/9-60 HGT-160-6T/9-75 HGT-160-6T/9-100 HGT-160-8T/3-3 HGT-160-8T/3-4 HGT-160-8T/3-5.5 HGT-160-8T/3-7.5 HGT-160-8T/3-10 HGT-160-8T/3-15 HGT-160-8T/6-4 HGT-160-8T/6-5.5 HGT-160-8T/6-7.5 HGT-160-8T/6-10 HGT-160-8T/6-15 HGT-160-8T/6-20 HGT-160-8T/6-25 HGT-160-8T/9-7.5 HGT-160-8T/9-10 HGT-160-8T/9-15 HGT-160-8T/9-20 HGT-160-8T/9-25 HGT-160-8T/9-30 HGT-160-8T/9-40 Speed (r/min) Maximum admissible current (A) 230V 400V 690V 710 16.11 725 725 725 705 12.82 710 16.11 725 725 725 725 960 16.50 975 965 965 970 970 970 965 965 970 970 970 973 975 965 970 970 970 973 975 980 980 985 705 9.53 705 12.82 710 16.11 725 725 725 705 12.82 710 16.11 725 725 725 725 725 725 725 725 725 725 725 730 9.30 12.70 7.33 17.00 9.81 21.70 12.53 7.40 9.30 12.70 7.33 17.00 9.81 21.70 12.53 31.70 18.30 9.53 11.50 6.64 15.20 8.78 22.60 13.05 27.90 16.11 34.64 20.00 41.57 24.00 15.20 8.78 22.60 13.05 27.90 16.11 34.64 20.00 41.57 24.00 53.69 31.00 65.82 38.00 22.60 13.05 27.90 16.11 34.64 20.00 41.57 24.00 53.69 31.00 65.82 38.00 84.80 48.96 96.99 56.00 131.64 76.00 5.50 7.40 9.30 12.70 7.33 17.00 9.81 21.70 12.53 7.40 9.30 12.70 7.33 17.00 9.81 21.70 12.53 31.70 18.30 35.85 20.70 12.70 7.33 17.00 9.81 21.70 12.53 31.70 18.30 35.85 20.70 41.60 24.02 60.79 35.10 Installed power (kW) 4.00 5.50 7.50 11.00 3.00 4.00 5.50 7.50 11.00 15.00 4.00 5.50 7.50 11.00 15.00 18.50 22.00 7.50 11.00 15.00 18.50 22.00 30.00 37.00 11.00 15.00 18.50 22.00 30.00 37.00 45.00 55.00 75.00 2.20 3.00 4.00 5.50 7.50 11.00 3.00 4.00 5.50 7.50 11.00 15.00 18.50 5.50 7.50 11.00 15.00 18.50 22.00 30.00 Maximum Sound Approx. weight (Kg) airflow pressure level HGT HGTX 3 (m /h) dB(A) Long Short 65200 73300 82200 94200 47200 64400 69200 78700 94300 103000 66000 76100 84000 102000 127000 136700 145000 75000 93500 120500 130000 140000 158000 171000 87000 104000 127000 135000 147000 165000 177000 193000 207500 54000 57500 74000 83500 97500 115000 70900 84500 77000 95000 109000 123000 130000 70000 87000 103000 117000 133000 140000 151000 80 81 82 83 79 79 81 82 83 86 81 82 83 85 86 87 89 83 85 86 87 88 89 91 85 86 87 88 89 90 91 92 93 76 77 79 80 81 83 76 77 79 80 82 83 84 79 80 82 83 84 85 86 317 330 360 419 284 326 339 369 429 485 327 335 393 407 500 543 563 404 418 510 553 573 656 714 428 520 563 583 666 724 844 932 1002 327 334 380 393 423 496 344 391 404 434 506 563 641 414 444 516 573 651 666 724 278 291 321 370 247 287 300 330 379 437 275 283 339 353 431 473 493 350 364 441 484 504 557 629 374 451 494 514 567 640 745 833 903 275 282 326 339 369 427 292 337 350 380 437 494 542 360 390 447 504 552 567 640 59 HGT HGTX Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at an equivalent distance of twice the fan’s span plus the impeller’s diameter, with a minimum of 1.5 m. Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. Model 125-4T/3-10 125-4T/3-15 125-4T/3-20 125-4T/3-25 125-4T/3-30 125-4T/3-40 125-4T/3-50 125-4T/3-60 125-4T/6-20 125-4T/6-25 125-4T/6-30 125-4T/6-40 125-4T/6-50 125-4T/6-60 125-4T/6-75 125-4T/6-100 125-4T/9-25 125-4T/9-30 125-4T/9-40 125-4T/9-50 125-4T/9-60 125-4T/9-75 125-4T/9-100 125-6T/3-4 125-6T/3-5.5 125-6T/3-7.5 125-6T/3-10 125-6T/3-15 125-6T/3-20 125-6T/6-5.5 125-6T/6-7.5 125-6T/6-10 125-6T/6-15 125-6T/6-20 125-6T/6-25 125-6T/9-10 125-6T/9-15 125-6T/9-20 125-6T/9-25 125-6T/9-30 125-8T/3-3 125-8T/3-4 125-8T/3-5.5 125-8T/3-7.5 125-8T/6-3 125-8T/6-4 125-8T/6-5.5 125-8T/6-7.5 125-8T/6-10 125-8T/9-4 125-8T/9-5.5 125-8T/9-7.5 125-8T/9-10 125-8T/9-15 140-6T/3-4 140-6T/3-5.5 140-6T/3-7.5 140-6T/3-10 140-6T/3-15 140-6T/3-20 140-6T/6-5.5 140-6T/6-7.5 140-6T/6-10 140-6T/6-15 140-6T/6-20 140-6T/6-25 140-6T/6-30 60 63 70 71 72 73 74 75 76 77 66 67 68 69 71 72 72 74 66 67 68 70 72 72 74 64 66 67 68 69 71 59 60 61 63 65 66 57 59 62 64 66 56 59 60 62 53 54 56 58 59 51 53 56 58 59 66 69 69 70 71 73 66 67 68 69 71 72 73 125 250500 1000200040008000 76 88 98 98 94 86 82 77 89 99 99 95 87 83 78 90 100 100 96 88 84 79 91 101 101 97 89 85 80 92 102 102 98 90 86 81 93 103 103 99 91 87 82 94 104 104 100 92 88 83 95 105 105 101 93 89 74 90 97 99 94 88 84 75 91 98 100 95 89 85 76 92 99 101 96 90 86 77 93 100 102 97 91 87 79 95 102 104 99 93 89 80 96 103 105 100 94 90 80 96 103 105 100 94 90 82 98 105 107 102 96 92 74 91 97 98 93 88 84 75 92 98 99 94 89 85 76 93 99 100 95 90 86 78 95 101 102 97 92 88 80 97 103 104 99 94 90 80 97 103 104 99 94 90 82 99 105 106 101 96 92 72 84 88 86 81 72 68 74 86 90 88 83 74 70 75 87 91 89 84 75 71 76 88 92 90 85 76 72 77 89 93 91 86 77 73 79 91 95 93 88 79 75 68 81 84 85 82 71 67 69 82 85 86 83 72 68 70 83 86 87 84 73 69 72 85 88 89 86 75 71 74 87 90 91 88 77 73 75 88 91 92 89 78 74 67 82 86 85 84 73 69 69 84 88 87 86 75 71 72 87 91 90 89 78 74 74 89 93 92 91 80 76 76 91 95 94 93 82 78 63 74 78 77 70 61 57 66 77 81 80 73 64 60 67 78 82 81 74 65 61 69 80 84 83 76 67 63 61 73 78 77 72 61 57 62 74 79 78 73 62 58 64 76 81 80 75 64 60 66 78 83 82 77 66 62 67 79 84 83 78 67 63 62 72 78 79 74 63 59 64 74 80 81 76 65 61 67 77 83 84 79 68 64 69 79 85 86 81 70 66 70 80 86 87 82 71 67 76 84 89 88 87 74 74 79 87 92 91 90 77 77 79 87 92 91 90 77 77 80 88 93 92 91 78 78 81 89 94 93 92 79 79 83 91 96 95 94 81 81 81 90 92 89 83 75 71 82 91 93 90 84 76 72 83 92 94 91 85 77 73 84 93 95 92 86 78 74 86 95 97 94 88 80 76 87 96 98 95 89 81 77 88 97 99 96 90 82 78 Model 140-6T/9-10 140-6T/9-15 140-6T/9-20 140-6T/9-25 140-6T/9-30 140-6T/9-40 140-6T/9-50 140-8T/3-3 140-8T/3-4 140-8T/3-5.5 140-8T/3-7.5 140-8T/3-10 140-8T/6-3 140-8T/6-4 140-8T/6-5.5 140-8T/6-7.5 140-8T/6-10 140-8T/6-15 140-8T/9-4 140-8T/9-5.5 140-8T/9-7.5 140-8T/9-10 140-8T/9-15 140-8T/9-20 160-6T/3-5.5 160-6T/3-7.5 160-6T/3-10 160-6T/3-15 160-6T/3-20 160-6T/3-25 160-6T/3-30 160-6T/6-10 160-6T/6-15 160-6T/6-20 160-6T/6-25 160-6T/6-30 160-6T/6-40 160-6T/6-50 160-6T/9-15 160-6T/9-20 160-6T/9-25 160-6T/9-30 160-6T/9-40 160-6T/9-50 160-6T/9-60 160-6T/9-75 160-6T/9-100 160-8T/3-3 160-8T/3-4 160-8T/3-5.5 160-8T/3-7.5 160-8T/3-10 160-8T/3-15 160-8T/6-4 160-8T/6-5.5 160-8T/6-7.5 160-8T/6-10 160-8T/6-15 160-8T/6-20 160-8T/6-25 160-8T/9-7.5 160-8T/9-10 160-8T/9-15 160-8T/9-20 160-8T/9-25 160-8T/9-30 160-8T/9-40 63 66 67 69 70 70 71 74 60 64 65 66 68 61 63 64 65 66 68 61 62 63 64 65 67 67 68 69 70 72 73 74 67 68 70 71 71 72 74 67 68 69 70 71 72 72 73 75 61 63 64 65 66 68 60 61 62 63 65 66 68 60 62 63 64 65 66 68 125 250500 1000200040008000 84 93 92 91 87 78 73 85 94 93 92 88 79 74 87 96 95 94 90 81 76 88 97 96 95 91 82 77 88 97 96 95 91 82 77 89 98 97 96 92 83 78 92 101 100 99 95 86 81 70 78 83 82 81 68 63 74 82 87 86 85 72 67 75 83 88 87 86 73 68 76 84 89 88 87 74 69 78 86 91 90 89 76 71 73 82 86 84 78 68 65 75 84 88 86 80 70 67 76 85 89 87 81 71 68 77 86 90 88 82 72 69 78 87 91 89 83 73 70 80 89 93 91 85 75 72 72 83 88 86 82 72 67 73 84 89 87 83 73 68 74 85 90 88 84 74 69 75 86 91 89 85 75 70 76 87 92 90 86 76 71 78 89 94 92 88 78 73 77 85 90 89 88 75 70 78 86 91 90 89 76 71 79 87 92 91 90 77 72 80 88 93 92 91 78 73 82 90 95 94 93 80 75 83 91 96 95 94 81 76 84 92 97 96 95 82 77 82 91 93 90 84 76 72 83 92 94 91 85 77 73 85 94 96 93 87 79 75 86 95 97 94 88 80 76 86 95 97 94 88 80 76 87 96 98 95 89 81 77 89 98 100 97 91 83 79 85 94 93 92 88 79 74 86 95 94 93 89 80 75 87 96 95 94 90 81 76 88 97 96 95 91 82 77 89 98 97 96 92 83 78 90 99 98 97 93 84 79 90 99 98 97 93 84 79 91 100 99 98 94 85 80 93 102 101 100 96 87 82 71 79 84 83 82 69 64 73 81 86 85 84 71 66 74 82 87 86 85 72 67 75 83 88 87 86 73 68 76 84 89 88 87 74 69 78 86 91 90 89 76 71 75 84 86 83 77 69 65 76 85 87 84 78 70 66 77 86 88 85 79 71 67 78 87 89 86 80 72 68 80 89 91 88 82 74 70 81 90 92 89 83 75 71 83 92 94 91 85 77 73 78 87 86 85 81 72 67 80 89 88 87 83 74 69 81 90 89 88 84 75 70 82 91 90 89 85 76 71 83 92 91 90 86 77 72 84 93 92 91 87 78 73 86 95 94 93 89 80 75 HGT HGTX Dimensions in mm HGT ØA ØBC (Consult motor build sizes) 160 180 200 225 250 ØD E* 280 long ØJ N Model 132 short (Std) HGT-125 1365 1320 570 - - - - - - 1250 500 700 15 20x18º HGT-125 1365 1320 - 700 - - - - - 1250 500 700 15 20x18º HGT-125 1365 1320 - - 765 825 - - - 1250 500 900 15 20x18º HGT-125 1365 1320 - - - - 910 - - 1250 500 1000 15 20x18º HGT-125 1365 1320 - - - - - 985 - 1250 600 1000 15 20x18º HGT-125 1365 1320 - - - - - - 1190 1250 700 1200 15 20x18º HGT-140 1515 1470 570 - - - - - - 1400 400 650 15 20x18º HGT-140 1515 1470 - 700 - - - - - 1400 450 700 15 20x18º HGT-140 1515 1470 - - 765 825 - - - 1400 550 900 15 20x18º HGT-140 1515 1470 - - - - 910 - - 1400 550 1000 15 20x18º HGT-140 1515 1470 - - - - - 985 - 1400 600 1000 15 20x18º HGT-160 1735 1680 570 - - - - - - 1600 400 650 19 24x15º HGT-160 1735 1680 - 700 - - - - - 1600 450 700 19 24x15º HGT-160 1735 1680 - - 765 825 - - - 1600 550 900 19 24x15º HGT-160 1735 1680 - - - - 910 - - 1600 550 1000 19 24x15º HGT-160 1735 1680 - - - - - 985 - 1600 600 1000 19 24x15º HGT-160 1735 1680 - - - - - - 1190 1600 700 1200 19 24x15º * The standard version is short casing. On request, long-casing with an inspection hatch. Motor build sizes depending on power Poles r/min 4T 1500 - - - - 132 160 160 180 180 200 225 225 250 280 6T 1000 - 132 132 132 160 160 180 200 200 225 250 280 280 280 750 132 132 160 160 160 180 200 225 225 250 - - - - 8T CV3 45,57,510 1520 25 30 40 50 6075100 HGTX ØA ØB ØD EH (Consult motor build sizes) Model ØJ N 132160180 200 225 250 280 HGT-X 125 1365 1320 1250 900 - - - - 15 HGT-X 125 1365 1320 1250 960 1743 1815 1850 - - - 1930 1995 - - 15 20x18º 20x18º HGT-X 125 1365 1320 1250 1100 - - - - - 2060 - 15 20x18º HGT-X 125 1365 1320 1250 1100 - - - - - - 2090 15 20x18º Motor build sizes depending on power Poles r/min 4T 1500 - - - - 132 160 160 180 180 200 225 225 250 280 6T 1000 - 132 132 132 160 160 180 200 200 225 250 280 280 280 750 132 132 160 160 160 180 200 225 225 250 - - - - 8T CV3 45,57,510 1520 25 30 40 50 6075100 61 HGT HGTX EXAMPLE OF SELECTION Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 125 Pe= Static pressure in mmH2O, Pa and inwg. Number of poles: 8 Number of blades: 3 Initial data • Working point: • Airflow: 12,500 m3/h • Loss of load: 7.5 mmH2O Steps for the selection of equipment On the pressure graph: • 1. Mark the working point, defined by the airflow (12,500 m3/h) and the loss of load (7.5 mmH2O). • 2. Select the curve of the equipment which is closest above the working point. In our case, a curve with a blade angle of 22º is obtained. Absorbed power On the power graph: • 3. Mark the working point, defined by the airflow (12,500 m3/h) and the selected blade angle (22º). • 4. Read the absorbed power on the power axis on the left. Pa= 560 W at the working point. • 5. Look for the straight red line which is closest to the working point above. On the right-hand side of the graph, the value of the installed motor power is obtained. In our case, this is 0.75 kW or 1 CV Recommended motor power kW (CV) EXAMPLE OF ORDER CODE HGT 125 HGT: Large long cased axial Impeller diameter fans with direct drive motor in cm. HGTX: Large long cased axial fans with external motor 62 8T Number of motor poles 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz 3 T=Three-phase Número M=Single-phase de palas 3 blades 6 blades 9 blades 1 22 Motor power Angle (CV) of inclination of the blades HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 125 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 4 Absorbed power Number of poles: 3 Recommended motor power kW (CV) Available features best efficiency point (BEP ) at the end of the series. 63 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 125 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 4 Available features best efficiency point (BEP ) at the end of the series. 64 Number of poles: 6 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 125 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 4 Absorbed power Number of poles: 9 Recommended motor power kW (CV) Available features best efficiency point (BEP ) at the end of the series. 65 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 125 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 6 Available features best efficiency point (BEP ) at the end of the series. 66 Number of poles: 3 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 125 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 6 Number of poles: 6 Available features best efficiency point (BEP ) at the end of the series. 67 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 125 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 6 Available features best efficiency point (BEP ) at the end of the series. 68 Number of poles: 9 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 125 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 8 Number of poles: 3 Available features best efficiency point (BEP ) at the end of the series. 69 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 125 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 8 Available features best efficiency point (BEP ) at the end of the series. 70 Number of poles: 6 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 125 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 8 Number of poles: 9 Available features best efficiency point (BEP ) at the end of the series. 71 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 140 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 6 Available features best efficiency point (BEP ) at the end of the series. 72 Number of poles: 3 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 140 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 6 Number of poles: 6 Available features best efficiency point (BEP ) at the end of the series. 73 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 140 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 6 Available features best efficiency point (BEP ) at the end of the series. 74 Number of poles: 9 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 140 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 8 Number of poles: 3 Available features best efficiency point (BEP ) at the end of the series. 75 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 140 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 8 Available features best efficiency point (BEP ) at the end of the series. 76 Number of poles: 6 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 140 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 8 Number of poles: 9 Available features best efficiency point (BEP ) at the end of the series. 77 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 160 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 6 Available features best efficiency point (BEP ) at the end of the series. 78 Number of poles: 3 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 160 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 6 Number of poles: 6 Available features best efficiency point (BEP ) at the end of the series. 79 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 160 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 6 Available features best efficiency point (BEP ) at the end of the series. 80 Number of poles: 9 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 160 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 8 Number of poles: 3 Available features best efficiency point (BEP ) at the end of the series. 81 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 160 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 8 Available features best efficiency point (BEP ) at the end of the series. 82 Number of poles: 6 HGT HGTX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Impeller diameter (cm): 160 Pe= Static pressure in mmH2O, Pa and inwg. Number of blades: 8 Number of poles: 9 Available features best efficiency point (BEP ) at the end of the series. 83 HGT HGTX Erp. BEP (best efficiency point) characteristics ∢ [º] PN MC EC VSD Angle of inclination of the blades in degreess Motor's nominal power in kW Measurement category Efficiency category S Static T Total Variable-speed drive SR Specific relationship ηe[%] Efficiency N Degree of efficiency [kW] Electrical power 3 [m /h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed HGT-125-4T/3 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 11 11 11 15 15 18.5 18.5 22 30 30 30 37 37 37 45 45 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 52.1% 52.7% 53.8% 55.8% 55.2% 54.5% 54.3% 52.6% 51.4% 51.5% 48.3% 46.3% 44.6% 74.3% 72.7% 72.2% 52.9 53.0 53.8 55.8 55.0 54.3 53.9 52.2 50.9 50.8 47.6 45.5 43.8 73.4 71.8 71.1 7.62 9.08 10.54 11.86 13.61 15.48 17.35 19.81 22.05 24.34 26.88 29.54 32.09 35.81 39.09 42.20 41511 46792 52185 57655 62205 67316 72427 77315 82218 84773 90252 94744 99128 116210 121252 125686 35.13 37.56 39.90 42.19 44.33 46.06 47.79 49.54 50.63 54.27 52.81 53.05 53.03 84.11 86.13 89.03 1472 1467 1461 1475 1471 1477 1474 1471 1483 1481 1479 1478 1476 1473 1476 1474 HGT-125-4T/6 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 15 15 18.5 22 30 30 30 37 37 45 55 55 75 75 75 75 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 57.6% 56.2% 56.4% 57.7% 57.3% 56.5% 56.7% 54.9% 53.8% 52.2% 49.8% 46.8% 44.7% 70.7% 70.3% 70.3% 57.5 56.0 56.1 57.3 56.7 55.9 56.0 54.1 52.9 51.2 48.7 45.7 43.4 69.4 68.9 68.9 11.86 14.36 16.61 18.64 21.37 24.19 27.14 30.76 34.57 38.69 43.83 48.64 53.11 58.84 63.99 68.95 48508 52757 58230 63848 68837 77896 80997 85910 88480 93638 102038 106474 110911 131496 136742 142272 51.71 56.25 59.12 61.84 65.30 64.43 69.77 72.17 77.19 79.23 78.56 78.56 78.56 116.23 120.78 125.19 1475 1469 1475 1473 1483 1481 1479 1477 1474 1476 1481 1479 1487 1485 1484 1483 HGT-125-4T/9 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 84 18.5 22 30 30 30 37 45 45 55 55 75 75 75 90 90 90 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.02 69.2% 61.9% 58.3% 56.6% 53.6% 52.4% 51.9% 50.6% 50.3% 50.7% 49.7% 49.3% 48.2% 74.6% 72.6% 70.5% 68.8 61.4 57.8 56.0 52.9 51.5 50.9 49.5 49.1 49.4 48.4 47.9 46.8 73.1 71.1 68.9 17.75 20.39 22.06 23.35 28.35 33.35 38.40 43.20 47.60 52.34 57.78 63.58 69.13 76.06 82.79 90.21 37304 41359 50452 73859 80439 87528 94456 97688 101406 106241 112236 120361 125253 140724 145177 149120 120.90 112.05 93.68 65.67 69.38 73.29 77.46 82.16 86.68 91.67 93.94 95.67 97.81 148.06 152.12 156.66 1474 1470 1483 1482 1478 1475 1476 1473 1480 1478 1486 1484 1483 1484 1483 1481 HGT HGTX Erp. BEP (best efficiency point) characteristics HGT-125-6T/3 [mmH2O] [RPM] ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 2.2 3 3 4 4 5.5 5.5 7.5 7.5 7.5 11 11 11 11 15 15 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 48.6% 49.2% 50.2% 52.1% 51.5% 52.1% 51.9% 50.3% 49.3% 48.6% 46.4% 44.3% 42.7% 71.1% 69.6% 69.1% 52.7 52.8 53.4 55.0 54.0 54.3 53.8 51.8 50.5 49.5 47.1 44.7 42.9 71.2 69.6 69.0 2.29 2.73 3.17 3.57 4.10 4.55 5.11 5.83 6.53 7.28 7.94 8.68 9.43 10.52 11.49 12.40 27197 30657 34190 37774 40755 44104 47452 50654 53010 56526 59317 62074 64946 76138 79441 82346 15.08 16.12 17.13 18.11 19.03 19.77 20.51 21.27 22.32 22.97 22.84 22.77 22.76 36.11 36.97 38.21 961 969 964 970 965 982 980 976 973 970 978 975 973 970 980 978 HGT-125-6T/6 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 4 5.5 5.5 5.5 7.5 7.5 11 11 11 15 15 15 18.5 18.5 22 22 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 53.8% 53.8% 53.9% 54.5% 54.2% 53.5% 54.2% 52.5% 51.1% 50.0% 47.4% 44.6% 41.8% 66.2% 66.3% 66.4% 56.6 56.1 55.9 56.2 55.4 54.4 54.9 52.8 51.2 49.9 47.3 44.4 41.5 65.8 65.9 65.9 3.57 4.23 4.89 5.54 6.35 7.19 7.98 9.04 10.22 11.37 12.95 14.37 15.95 17.68 19.07 20.55 31781 34565 38151 41832 45100 51036 53067 56286 57719 61349 66852 69759 72666 86152 89589 93213 22.20 24.14 25.38 26.55 28.03 27.66 29.95 30.98 33.26 34.01 33.72 33.72 33.72 49.89 51.84 53.74 970 983 981 978 974 970 977 974 971 980 977 974 977 975 977 975 HGT-125-6T/9 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 5.5 7.5 7.5 7.5 11 11 15 15 15 18.5 18.5 22 22 30 30 30 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 66.1% 59.2% 55.2% 53.5% 51.3% 50.1% 49.6% 48.4% 48.2% 47.7% 46.5% 46.5% 45.5% 71.3% 69.4% 67.4% 67.9 60.6 56.4 54.5 51.8 50.2 49.6 48.3 48.0 47.5 46.2 46.1 45.0 70.7 68.8 66.7 5.22 6.00 6.56 6.94 8.33 9.80 11.28 12.70 14.05 15.62 17.36 18.95 20.60 22.38 24.36 26.55 24441 27097 33055 48390 52702 57346 61885 64003 65542 69606 73534 78857 82062 92199 95116 97699 51.89 48.10 40.21 28.19 29.78 31.46 33.25 35.27 37.94 39.35 40.32 41.07 41.98 63.56 65.30 67.25 979 975 973 972 976 972 980 977 975 978 975 977 975 982 980 978 85 HGT HGTX Erp. BEP (best efficiency point) characteristics HGT-125-8T/3 [mmH2O] [RPM] ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 1.1 1.5 1.5 1.5 2.2 2.2 2.2 3 3 4 4 4 5.5 5.5 5.5 5.5 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 42.3% 44.2% 45.1% 46.3% 45.8% 45.2% 45.0% 44.6% 44.3% 43.9% 41.5% 39.6% 41.0% 68.3% 66.9% 66.4% 48.2 49.8 50.3 51.1 50.2 49.3 48.8 48.1 47.5 46.8 44.2 42.0 43.3 70.4 68.7 68.0 1.15 1.32 1.54 1.75 2.01 2.28 2.56 2.86 3.17 3.49 3.86 4.23 4.27 4.77 5.21 5.62 20612 23235 25912 28629 30888 33426 35964 38311 38268 42094 44508 46875 49222 57704 60208 62409 8.66 9.26 9.84 10.40 10.93 11.36 11.78 12.24 13.50 13.38 13.23 13.12 13.07 20.74 21.24 21.95 716 720 715 710 719 715 710 717 713 722 719 716 733 731 730 728 HGT-125-8T/6 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 1.5 2.2 2.2 3 3 4 4 4 5.5 5.5 7.5 7.5 7.5 11 11 11 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 47.8% 46.7% 46.8% 48.9% 48.0% 48.2% 48.3% 46.8% 48.4% 48.0% 46.3% 43.6% 41.3% 66.1% 65.7% 65.8% 52.6 50.9 50.7 52.5 51.2 51.1 50.9 49.1 50.5 49.8 47.9 44.8 42.3 66.9 66.2 66.1 1.75 2.12 2.45 2.69 3.12 3.47 3.90 4.42 4.66 5.15 5.77 6.40 7.03 7.70 8.38 9.03 24087 26197 28914 31704 34181 38680 40219 42659 45625 46496 50667 52870 55073 65294 67899 70645 12.75 13.87 14.58 15.25 16.10 15.89 17.20 17.80 18.18 19.54 19.37 19.37 19.37 28.66 29.78 30.87 710 717 712 719 713 722 719 715 732 730 733 731 730 735 733 732 HGT-125-8T/9 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 86 2.2 3 3 3 4 5.5 5.5 5.5 7.5 7.5 7.5 11 11 11 11 15 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 57.4% 52.5% 48.9% 47.4% 45.7% 48.1% 47.7% 46.5% 47.1% 47.1% 45.9% 46.0% 45.1% 69.4% 67.6% 67.1% 61.1 55.8 52.0 50.4 48.2 50.4 49.5 48.0 48.4 48.2 46.7 46.5 45.4 69.5 67.6 67.0 2.62 2.94 3.22 3.41 4.07 4.44 5.11 5.75 6.26 6.89 7.65 8.32 9.05 10.01 10.90 11.61 18524 20537 25052 36675 39942 43462 46902 48507 49674 52754 55731 59770 62194 69877 72088 74046 29.81 27.63 23.10 16.19 17.11 18.07 19.10 20.26 21.79 22.60 23.16 23.52 24.12 36.51 37.51 38.63 710 716 712 710 718 733 730 728 732 730 728 733 732 730 728 733 HGT HGTX Erp. BEP (best efficiency point) characteristics HGT-140-6T/3 [mmH2O] [RPM] ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 4 5.5 5.5 7.5 7.5 11 11 11 15 15 15 18.5 18.5 18.5 22 22 C C C C C C C C C C C B B B B B S S S S S S S S S S S T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 43.6% 45.1% 46.1% 47.8% 47.3% 47.2% 47.0% 44.4% 43.6% 43.2% 40.9% 64.0% 64.2% 61.6% 60.7% 60.2% 46.1 47.3 47.8 49.2 48.3 47.9 47.4 44.5 43.6 43.1 40.7 63.7 63.8 61.2 60.2 59.7 4.00 4.65 5.40 6.08 6.97 7.85 8.79 10.16 11.39 12.60 13.90 15.73 17.03 18.73 20.28 21.90 36390 41020 45747 50542 54531 59012 63492 68187 71105 74264 77986 94783 99158 101655 106107 110043 17.60 18.81 19.99 21.13 22.20 23.07 23.94 24.30 25.65 26.91 26.76 39.00 40.47 41.68 42.63 44.01 966 982 979 975 971 978 975 971 980 978 975 978 976 973 975 973 HGT-140-6T/6 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 7.5 7.5 11 11 11 15 15 18.5 18.5 22 30 30 30 37 37 37 C C C C C C C C C C C B B B B B S S S S S S S S S S S T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 49.3% 48.2% 48.9% 49.4% 48.5% 47.9% 48.1% 46.1% 44.2% 43.7% 42.6% 61.5% 60.3% 59.9% 59.5% 59.5% 50.7 49.0 49.4 49.6 48.5 47.8 47.9 45.8 43.8 43.2 42.1 60.8 59.6 59.1 58.6 58.6 6.08 7.36 8.42 9.55 11.07 12.53 14.06 16.09 18.32 20.15 22.47 25.18 27.67 30.15 32.79 35.32 42524 46249 51047 55972 60345 68287 71005 75312 80549 84172 89450 105037 110368 114996 119625 124508 25.90 28.17 29.61 30.98 32.71 32.27 34.95 36.15 36.94 38.41 39.35 54.13 55.55 57.67 59.87 61.99 975 970 976 973 969 978 975 977 974 976 982 980 977 981 980 978 HGT-140-6T/9 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 11 11 15 15 15 18.5 22 30 30 30 30 37 37 45 45 55 C C C C C C C C C C C B B B B B S S S S S S S S S S S T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.01 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 59.9% 53.0% 49.4% 47.9% 45.4% 43.9% 43.9% 43.6% 43.1% 43.4% 42.8% 65.3% 64.5% 63.6% 61.9% 60.4% 60.2 53.1 49.4 47.9 45.2 43.6 43.4 43.0 42.4 42.7 42.0 64.5 63.6 62.6 60.8 59.3 9.00 10.45 11.43 12.09 14.68 17.45 19.93 22.03 24.40 26.83 29.85 31.99 35.49 38.77 42.20 45.72 32703 36257 44228 64747 70516 76730 82804 85637 88897 93135 100645 116137 119380 123186 127100 130545 60.56 56.12 46.93 32.90 34.75 36.71 38.80 41.15 43.42 45.91 46.65 66.06 70.46 73.50 75.48 77.70 975 970 980 978 974 975 976 982 980 978 976 980 978 984 983 985 87 HGT HGTX Erp. BEP (best efficiency point) characteristics HGT-140-8T/3 [mmH2O] [RPM] ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 2.2 2.2 3 3 3 4 4 5.5 5.5 5.5 7.5 7.5 7.5 11 11 11 C C C C C C C C C C C B B B B B S S S S S S S S S S S T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 38.7% 39.2% 41.3% 42.4% 41.9% 42.1% 41.9% 43.3% 42.4% 41.9% 40.4% 63.2% 63.4% 61.5% 60.2% 59.7% 43.2 43.2 45.0 45.7 44.8 44.7 44.2 45.5 44.3 43.5 41.7 64.2 64.2 62.1 60.5 59.8 1.96 2.33 2.62 2.99 3.43 3.83 4.30 4.60 5.16 5.71 6.20 6.93 7.51 8.16 8.91 9.62 27580 31089 34671 38306 41329 44725 48120 51261 53756 56323 59552 71836 75151 77044 80418 83401 10.11 10.81 11.48 12.14 12.75 13.25 13.75 14.28 14.96 15.62 15.43 22.40 23.24 23.94 24.49 25.28 720 714 719 715 710 720 716 732 730 728 732 730 728 734 732 731 HGT-140-8T/6 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 3 4 4 5.5 5.5 5.5 7.5 7.5 11 11 11 15 15 15 15 18.5 C C C C C C C C C C C B B B B B S S S S S S S S S S S T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 43.7% 43.4% 43.6% 47.5% 46.6% 46.0% 47.0% 45.5% 44.6% 43.8% 41.5% 61.2% 60.0% 59.2% 58.8% 58.3% 47.1 46.3 46.0 49.8 48.5 47.6 48.3 46.4 45.3 44.1 41.6 61.2 60.0 59.1 58.6 58.0 2.98 3.56 4.11 4.33 5.02 5.68 6.26 7.09 7.97 8.82 10.05 11.01 12.10 13.27 14.43 15.69 32229 35052 38688 42421 45735 51754 53815 57078 58997 62213 67794 79607 83648 87155 90663 94364 14.88 16.18 17.01 17.79 18.79 18.54 20.07 20.77 22.14 22.80 22.60 31.09 31.91 33.13 34.39 35.61 715 722 717 733 731 728 732 729 734 732 730 733 732 730 728 731 HGT-140-8T/9 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 88 4 5.5 5.5 5.5 7.5 7.5 11 11 11 15 15 15 18.5 18.5 22 22 C C C C C C C C C C C B B B B B S S S S S S S S S S S T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 53.4% 50.9% 47.5% 46.1% 44.4% 43.4% 43.5% 42.4% 42.2% 43.2% 42.1% 64.6% 63.2% 61.6% 61.9% 60.1% 55.7 53.0 49.3 47.7 45.6 44.1 43.9 42.5 42.2 43.2 42.0 64.4 63.0 61.3 61.5 59.6 4.40 4.73 5.18 5.48 6.54 7.69 8.76 9.85 10.91 11.73 13.03 14.10 15.76 17.41 18.37 20.01 24785 27479 33520 49072 53444 58154 62756 64904 66465 70586 74569 87828 90477 93362 96329 98939 34.78 32.24 26.95 18.90 19.96 21.09 22.29 23.64 25.43 26.37 27.03 38.06 40.47 42.22 43.35 44.63 715 732 730 729 731 728 732 730 728 732 730 729 731 729 738 737 HGT HGTX Erp. BEP (best efficiency point) characteristics HGT-160-6T/3 [mmH2O] [RPM] ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 7.5 11 11 15 15 18.5 18.5 22 22 30 30 37 37 37 45 45 C C C C C C C C C C C B B B B B S S S S S S S S S S S T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 45.2% 46.2% 47.1% 48.4% 47.8% 46.8% 46.6% 45.0% 44.1% 44.3% 41.9% 66.1% 66.3% 63.6% 62.9% 62.4% 45.9 46.5 47.2 48.3 47.6 46.5 46.2 44.6 43.5 43.7 41.3 65.3 65.4 62.7 61.9 61.4 7.53 8.87 10.30 11.72 13.45 15.45 17.32 19.83 22.24 24.20 26.72 29.69 32.14 35.35 38.17 41.21 54320 61231 68287 75445 81399 88088 94775 100960 105875 110931 117291 141484 148014 151742 158387 164263 22.98 24.57 26.10 27.60 29.00 30.14 31.26 32.47 34.02 35.51 35.09 50.94 52.85 54.44 55.68 57.49 969 975 971 979 976 978 975 976 973 980 978 982 980 978 984 983 HGT-160-6T/6 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 15 15 18.5 18.5 22 30 30 37 37 45 45 55 55 75 75 75 C C C C C C C C C C C B B B B B S S S S S S S S S S S T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 49.9% 48.7% 48.4% 48.9% 48.4% 48.6% 48.8% 47.6% 45.7% 44.8% 43.4% 62.9% 61.7% 61.6% 61.2% 61.2% 49.9 48.5 48.1 48.5 47.9 48.0 48.1 46.8 44.8 43.8 42.3 61.8 60.5 60.4 59.9 59.9 11.72 14.19 16.58 18.81 21.63 24.04 26.98 30.37 34.59 37.89 43.04 47.98 52.72 57.10 62.08 66.88 63476 69036 76198 83550 90077 101933 105991 112419 120236 124823 133523 156789 164748 171656 178566 185855 33.83 36.80 38.68 40.46 42.72 42.15 45.64 47.22 48.25 49.92 51.39 70.70 72.55 75.33 78.19 80.97 979 975 976 973 974 980 978 981 979 985 982 984 982 989 988 987 HGT-160-6T/9 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 18.5 22 30 30 30 37 45 45 55 55 75 75 75 90 90 90 C C C C C C C C C C C B B B B B S S S S S S S S S S S T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 59.3% 52.9% 50.2% 48.7% 46.2% 45.4% 45.5% 44.3% 44.0% 44.4% 44.4% 67.2% 66.4% 65.2% 63.5% 61.6% 59.0 52.4 49.7 48.1 45.4 44.5 44.5 43.3 42.9 43.2 43.1 65.9 65.0 63.8 62.0 60.0 17.72 20.41 21.93 23.21 28.18 32.93 37.51 42.20 46.51 51.12 56.15 60.57 67.20 73.66 80.18 87.35 48815 54121 66019 96649 105260 114536 123602 127831 136572 139024 150233 173360 178199 183881 189724 194865 79.09 73.30 61.29 42.97 45.39 47.95 50.68 53.75 55.04 59.97 60.93 86.28 92.03 96.00 98.58 101.48 975 975 982 981 977 980 985 983 984 983 989 989 987 992 992 991 89 HGT HGTX Erp. BEP (best efficiency point) characteristics HGT-160-8T/3 [mmH2O] [RPM] ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 4 4 5.5 5.5 7.5 7.5 7.5 11 11 11 15 15 15 18.5 18.5 18.5 C C C C C C C C C C C B B B B B S S S S S S S S S S S T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 40.7% 41.2% 45.3% 46.5% 46.7% 46.2% 46.0% 44.6% 43.7% 43.0% 41.6% 65.5% 65.5% 62.4% 61.0% 60.5% 43.5 43.5 47.4 48.2 48.1 47.3 46.7 45.0 43.8 43.1 41.6 65.4 65.4 62.1 60.6 60.1 3.64 4.33 4.67 5.31 5.99 6.81 7.64 8.71 9.77 10.88 11.75 13.03 14.15 15.70 17.14 18.50 41169 46407 51755 57179 61692 66761 71830 76517 80242 85565 89790 107486 112179 115004 120041 124494 13.20 14.12 14.99 15.86 16.66 17.31 17.96 18.65 19.54 20.11 20.00 29.19 30.36 31.27 31.98 33.02 721 716 732 729 733 730 728 733 730 728 732 730 729 731 729 728 HGT-160-8T/6 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 5.5 7.5 7.5 11 11 11 15 15 18.5 18.5 22 22 30 30 30 37 C C C C C C C C C C C B B B B B S S S S S S S S S S S T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 47.9% 47.6% 47.8% 48.9% 48.0% 47.4% 48.6% 47.1% 44.8% 44.6% 43.4% 62.6% 60.2% 59.3% 58.9% 59.5% 49.7 48.9 48.7 49.4 48.2 47.4 48.5 46.9 44.6 44.3 43.0 62.1 59.6 58.7 58.2 58.7 5.31 6.32 7.31 8.20 9.50 10.75 11.80 13.37 15.32 16.88 18.74 21.00 23.54 25.82 28.07 29.98 48108 52322 57750 63322 68269 77254 80330 85202 90276 93251 101197 118830 124862 130097 135334 140858 19.43 21.14 22.22 23.24 24.54 24.21 26.22 27.12 27.95 29.67 29.52 40.61 41.67 43.27 44.91 46.51 729 732 729 734 731 728 732 730 732 730 738 737 736 734 733 739 HGT-160-8T/9 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 90 11 11 11 11 15 15 18.5 22 22 30 30 30 37 37 37 37 C C C C C C C C C C C B B B B B S S S S S S S S S S S T T T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 59.2% 52.4% 48.9% 47.4% 45.9% 44.9% 44.1% 44.3% 43.8% 43.3% 42.6% 64.7% 64.5% 62.9% 61.2% 59.4% 60.0 52.7 49.0 47.5 45.9 44.7 43.8 43.9 43.3 42.7 42.0 64.0 63.7 62.0 60.3 58.4 7.72 8.97 9.81 10.38 12.32 14.50 16.84 18.37 20.35 22.82 25.37 27.42 30.12 33.27 36.21 39.45 36997 41018 50036 73250 79776 86806 93677 96883 100570 105365 111878 131101 135056 139362 143791 147687 45.43 42.11 35.21 24.68 26.07 27.54 29.11 30.88 32.57 34.45 35.51 49.71 52.86 55.14 56.62 58.29 735 732 730 729 732 728 730 738 737 736 735 734 739 738 737 735 HGT HGTX Erp. BEP (best efficiency point) characteristics HGTX-125-4T/3 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 11 11 11 15 15 18.5 18.5 22 30 30 30 37 37 45 45 45 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 51.1% 51.7% 52.7% 54.7% 54.1% 53.4% 53.2% 51.6% 50.4% 50.4% 47.3% 45.4% 43.7% 72.8% 71.3% 70.7% 51.8 51.9 52.8 54.6 53.9 53.2 52.8 51.1 49.8 49.8 46.6 44.6 42.9 71.9 70.3 69.7 7.77 9.26 10.75 12.11 13.89 15.80 17.71 20.22 22.51 24.84 27.43 30.15 32.74 36.54 39.88 43.06 41511 46792 52185 57655 62205 67316 72427 77315 82218 84773 90252 94744 99128 116210 121252 125686 35.13 37.56 39.90 42.19 44.33 46.06 47.79 49.54 50.63 54.27 52.81 53.05 53.03 84.11 86.13 89.03 1471 1466 1460 1474 1471 1477 1474 1470 1483 1481 1479 1477 1475 1477 1475 1473 HGTX-125-4T/6 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 15 15 18.5 22 30 30 30 37 37 45 55 55 75 75 75 75 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 56.4% 55.1% 55.3% 56.5% 56.1% 55.4% 55.5% 53.8% 52.7% 51.2% 48.8% 45.9% 43.8% 69.3% 68.9% 68.9% 56.4 54.9 55.0 56.1 55.6 54.7 54.8 53.0 51.8 50.2 47.7 44.7 42.5 68.0 67.5 67.5 12.10 14.66 16.95 19.02 21.81 24.68 27.70 31.39 35.28 39.48 44.72 49.63 54.19 60.04 65.30 70.36 48508 52757 58230 63848 68837 77896 80997 85910 88480 93638 102038 106474 110911 131496 136742 142272 51.71 56.25 59.12 61.84 65.30 64.43 69.77 72.17 77.19 79.23 78.56 78.56 78.56 116.23 120.78 125.19 1474 1469 1475 1472 1483 1481 1479 1476 1473 1476 1481 1479 1486 1485 1484 1482 HGTX-125-4T/9 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 18.5 22 30 30 30 37 45 55 55 75 75 75 75 90 90 90 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.02 67.8% 60.6% 57.2% 55.4% 52.5% 51.3% 50.8% 49.8% 49.3% 50.0% 48.7% 48.3% 47.3% 73.1% 71.2% 69.1% 67.4 60.1 56.6 54.8 51.8 50.4 49.9 48.8 48.1 48.7 47.4 46.9 45.8 71.6 69.6 67.4 18.12 20.81 22.51 23.82 28.92 34.03 39.18 43.85 48.57 53.06 58.96 64.88 70.54 77.61 84.48 92.05 37304 41359 50452 73859 80439 87528 94456 97688 101406 106241 112236 120361 125253 140724 145177 149120 120.90 112.05 93.68 65.67 69.38 73.29 77.46 82.16 86.68 91.67 93.94 95.67 97.81 148.06 152.12 156.66 1473 1470 1483 1482 1478 1474 1476 1481 1479 1487 1485 1484 1482 1484 1482 1481 91 HGT HGTX Erp. BEP (best efficiency point) characteristics HGTX-125-6T/3 [mmH2O] [RPM] ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 3 3 4 4 5.5 5.5 5.5 7.5 7.5 7.5 11 11 11 11 15 15 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 46.2% 46.9% 48.6% 50.1% 50.9% 50.5% 50.6% 49.3% 48.3% 47.6% 45.5% 43.4% 41.8% 69.7% 68.2% 67.7% 50.1 50.3 51.7 52.8 53.3 52.6 52.4 50.8 49.4 48.4 46.1 43.8 41.9 69.7 68.2 67.6 2.42 2.87 3.28 3.72 4.15 4.70 5.24 5.94 6.67 7.42 8.10 8.86 9.62 10.74 11.72 12.66 27197 30657 34190 37774 40755 44104 47452 50654 53010 56526 59317 62074 64946 76138 79441 82346 15.08 16.12 17.13 18.11 19.03 19.77 20.51 21.27 22.32 22.97 22.84 22.77 22.76 36.11 36.97 38.21 973 968 972 968 984 981 979 976 973 970 977 975 973 970 979 977 HGTX-125-6T/6 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 4 5.5 5.5 5.5 7.5 7.5 11 11 11 15 15 15 18.5 18.5 22 22 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 51.7% 52.0% 52.5% 53.3% 53.1% 52.4% 53.2% 51.5% 50.1% 49.0% 46.4% 43.7% 41.0% 64.9% 65.0% 65.0% 54.4 54.3 54.4 54.9 54.3 53.3 53.7 51.7 50.1 48.9 46.3 43.5 40.7 64.5 64.5 64.5 3.72 4.37 5.02 5.67 6.48 7.34 8.14 9.22 10.43 11.60 13.21 14.66 16.28 18.04 19.46 20.97 31781 34565 38151 41832 45100 51036 53067 56286 57719 61349 66852 69759 72666 86152 89589 93213 22.20 24.14 25.38 26.55 28.03 27.66 29.95 30.98 33.26 34.01 33.72 33.72 33.72 49.89 51.84 53.74 968 983 980 978 973 970 977 974 970 979 976 974 977 974 976 975 HGTX-125-6T/9 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 92 5.5 7.5 7.5 7.5 11 11 15 15 15 18.5 18.5 22 22 30 30 30 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 64.5% 58.0% 54.1% 52.4% 50.3% 49.1% 48.6% 47.4% 47.2% 46.8% 45.6% 45.6% 44.6% 69.8% 68.0% 66.0% 66.2 59.4 55.2 53.4 50.7 49.2 48.6 47.3 47.0 46.5 45.2 45.2 44.1 69.3 67.4 65.3 5.35 6.12 6.69 7.08 8.50 10.00 11.51 12.95 14.34 15.94 17.71 19.33 21.02 22.84 24.86 27.09 24441 27097 33055 48390 52702 57346 61885 64003 65542 69606 73534 78857 82062 92199 95116 97699 51.89 48.10 40.21 28.19 29.78 31.46 33.25 35.27 37.94 39.35 40.32 41.07 41.98 63.56 65.30 67.25 979 975 973 971 976 972 980 977 974 977 975 977 975 981 980 978 HGT HGTX Erp. BEP (best efficiency point) characteristics HGTX-125-8T/3 [mmH2O] [RPM] ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 1.1 1.5 1.5 2.2 2.2 2.2 3 3 3 4 4 4 5.5 5.5 5.5 5.5 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 39.7% 41.6% 42.5% 43.7% 43.3% 42.8% 44.2% 42.5% 42.3% 42.0% 39.9% 38.1% 39.6% 66.3% 65.2% 64.9% 45.5 47.0 47.5 48.3 47.5 46.8 47.9 45.8 45.3 44.8 42.4 40.4 41.9 68.3 66.9 66.4 1.22 1.41 1.63 1.86 2.12 2.41 2.61 3.00 3.33 3.65 4.02 4.39 4.42 4.91 5.34 5.75 20612 23235 25912 28629 30888 33426 35964 38311 38268 42094 44508 46875 49222 57704 60208 62409 8.66 9.26 9.84 10.40 10.93 11.36 11.78 12.24 13.50 13.38 13.23 13.12 13.07 20.74 21.24 21.95 713 718 713 721 717 713 719 715 711 721 718 715 733 731 729 728 HGTX-125-8T/6 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 2.2 2.2 2.2 3 3 4 4 5.5 5.5 5.5 7.5 7.5 7.5 11 11 11 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 45.1% 44.1% 44.4% 46.5% 45.8% 46.1% 46.4% 48.7% 47.0% 46.7% 45.4% 42.7% 40.5% 64.8% 64.4% 64.4% 49.7 48.3 48.1 50.0 48.9 48.9 48.9 51.1 49.0 48.5 46.9 43.9 41.4 65.5 64.8 64.7 1.86 2.24 2.58 2.83 3.27 3.63 4.06 4.24 4.81 5.29 5.88 6.53 7.18 7.86 8.55 9.21 24087 26197 28914 31704 34181 38680 40219 42659 45625 46496 50667 52870 55073 65294 67899 70645 12.75 13.87 14.58 15.25 16.10 15.89 17.20 17.80 18.18 19.54 19.37 19.37 19.37 28.66 29.78 30.87 721 715 710 717 712 721 718 734 731 729 733 731 729 734 733 732 HGTX-125-8T/9 ∢ [º] PN MC EC VSD SR ηe[%] N [kW] [m3/h] [mmH2O] [RPM] 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 3 3 3 4 4 5.5 5.5 7.5 7.5 7.5 11 11 11 11 11 15 C C C C C C C C C C C C C B B B S S S S S S S S S S S S S T T T NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 56.3% 50.0% 46.7% 46.1% 44.0% 46.6% 46.4% 46.3% 46.1% 46.2% 45.5% 45.1% 44.2% 68.0% 66.2% 65.7% 59.9 53.2 49.7 49.0 46.4 48.8 48.2 47.9 47.4 47.2 46.3 45.5 44.4 68.0 66.2 65.7 2.67 3.09 3.37 3.50 4.23 4.59 5.25 5.77 6.39 7.03 7.72 8.49 9.24 10.21 11.12 11.85 18524 20537 25052 36675 39942 43462 46902 48507 49674 52754 55731 59770 62194 69877 72088 74046 29.81 27.63 23.10 16.19 17.11 18.07 19.10 20.26 21.79 22.60 23.16 23.52 24.12 36.51 37.51 38.63 719 714 711 722 716 732 730 733 731 730 735 733 732 730 728 732 Accessories See accessories section. INT AR RFT/ RFM PANELS RT PT/H BTUB BAC PS S SI PV 93 HTM HTM Mobile long-cased axial fans Mobile fans with possibility of directing airflow. Fan: • Sheet steel tubular casing. • Impeller in polyamide 6 reinforced with fibre glass • Protection guard against contacts, in accordance with standard UNE 100250, on both sides • Connection box with start-stop switch that can be rearmed manually to avoid switching the fan on accidentally (ISO 12100-2) • Airflow direction from motor to impeller Motor: • Single-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors, with ball bearings and IP55 protection, except single-phase versions from size 35 to size 56, IP54 protection. • Single-phase 230V.-50Hz., and three-phase 230/400V.-50Hz. • Working temperature: -25ºC.+ 50ºC Finish: • Anticorrosive finish in polyester resin, polymerised at 190ºC, after alkaline degreasing and phosphate-free pre-treatment. On request: • Airflow direction from impeller to motor • 100% reversible impellers. • Special windings for different voltages • ATEX certification, Category 2 Order code HTM 35 Mobile long-cased axial fans 2T Impeller diameter in cm. Number of motor poles 2=2900 r/min. 50 Hz 4=1400 r/min. 50 Hz T=Three-phase M=Single-phase Technical characteristics Model Speed (r/min) HTM-35-2T HTM-35-2M HTM-35-4T HTM-35-4M HTM-40-4T HTM-40-4M HTM-45-4T HTM-45-4M HTM-56-4T HTM-56-4M HTM-63-4T 2710 2780 1320 1380 1350 1370 1370 1400 1380 1400 1400 Maximum admissible current (A) 230V 400V 1.92 1.11 2.53 0.65 0.38 0.65 1.66 0.96 2 2.02 1.17 2.76 2.92 1.69 4.4 4.03 2.32 Installed power (kW) 0.37 0.37 0.09 0.09 0.25 0.25 0.37 0.37 0.55 0.55 1.1 Maximum airflow (m3/h) 5750 5750 3100 3100 5150 5150 7100 7100 11050 11050 17000 Sound Approx. weight pressure level (Kg) dB(A) 77 77 59 59 64 64 68 68 72 72 74 13 13 12 12 19 19 22 22 27 27 35 Erp. BEP (best efficiency point) characteristics MC EC VSD SR Model HTM-35-2T HTM-35-2M HTM-35-4T HTM-35-4M HTM-40-4T HTM-40-4M HTM-45-4T HTM-45-4M HTM-56-4T HTM-56-4M HTM-63-4T 94 MC A A A A A A A A A A C ηe[%] Efficiency N Degree of efficiency [kW] Electrical power [m3/h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship EC VSD SR S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 ηe[%] 37.1% 36.5% 27.4% 25.6% 32.0% 28.2% 33.4% 29.6% 33.2% 32.7% 45.3% N (kW) (m3/h) 45.2 44.6 39.3 37.4 41.7 37.5 41.8 37.6 40.6 40.1 51.1 0.515 0.524 0.128 0.137 0.289 0.329 0.475 0.538 0.660 0.669 1.179 2998 2983 1857 1851 3401 3332 4228 4257 6808 6622 10593 (mmH2O) 23.40 23.52 6.94 6.96 10.00 10.23 13.80 13.73 11.81 12.13 18.50 (RPM) 2737 2791 1400 1425 1396 1401 1392 1410 1405 1422 1412 HTM Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at an equivalent distance of twice the fan’s span plus the impeller’s diameter, with a minimum of 1.5 m. Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. Model 35-2 35-4 40-4 63 42 24 29 125 250500 1000200040008000 59 71 79 84 84 80 73 41 53 61 66 66 62 55 46 58 66 71 71 67 60 Model 45-4 56-4 63-4 63 33 39 43 125 250500 1000200040008000 50 62 70 75 75 71 64 56 69 76 81 82 77 70 60 73 80 85 86 81 74 Dimensions in mm Model A B C DE F HTM-35 280 736 420 415 355 489 HTM-40 320 775 481 450 410 596 HTM-45 360 795 481 453 460 596 HTM-56 400 945 594 522 560 726 HTM-63 430 978 594 522 640 805 Characteristics of jet with fan positioned 1 metre away from point 0 Accessories See accessories section. INT AR RFT/ RFM PANELS BTUB S SI 95 HPX HPX Long cased axial fans with external motor free Long cased belt-driven axial fans with casing opening up to 180º. Fan: • Long casing with sheet steel twist-lock cap. • Impellers made from cast aluminium • Sealed transmission unit (IP66) with double retention system • Airflow direction from motor to impeller Motor: • S ingle-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors, with bearings, IP55 protection. • Single-phase 230V. -50Hz. and threephase 230/400V.-50Hz. (up to 5.5CV.) and 400/690V.-50Hz. (power over 5.5CV.) • Working temperature: -25ºC.+ 150ºC. On request: • Airflow direction from impeller to motor • 100% reversible impellers. • Special windings for different voltages • ATEX Certification, category 2 (see HPX/ATEX series) Finish: • Anticorrosive finish in polyester resin, polymerised at 190ºC, after alkaline degreasing and phosphate-free pre-treatment. Order code HPX Mobile long-cased axial fans 35 Impeller diameter in cm. 2T 0,75 Number of motor poles T=Three-phase 2=2900 r/min. 50 Hz 4=1400 r/min. 50 Hz Power motor (c.v) Technical characteristics Model HPX-35-2T-0.75 HPX-35-4T-0.33 HPX-45-4T-0.33 HPX-45-4T-0.50 HPX-50-4T-0.75 HPX-50-4T-1 HPX-56-4T-0.75 HPX-56-4T-1 HPX-56-4T-1.5 HPX-63-4T-1.5 HPX-63-4T-2 HPX-71-4T-1.5 HPX-71-4T-2 HPX-71-4T-3 HPX-80-4T-3 HPX-80-4T-4 HPX-80-4T-5.5 HPX-90-4T-5.5 HPX-90-4T-7.5 HPX-100-4T-10 HPX-100-4T-15 96 Speed (r/min) Maximum admissible current (A) 230V 400V 690V 2720 2.57 1420 1.66 1200 1.66 1420 2.02 1310 2.92 1500 3.10 1380 2.92 1420 3.10 1420 4.03 1300 4.03 1420 5.96 1200 4.03 1350 5.96 1450 8.36 1200 8.36 1350 10.96 1450 14.10 1280 14.10 1400 1450 1450 1.49 0.96 0.96 1.17 1.69 1.79 1.69 1.79 2.32 2.32 3.44 2.32 3.44 4.83 4.83 6.33 8.12 8.12 11.60 6.72 14.20 8.20 20.20 11.60 Installed power (kW) 0.55 0.25 0.25 0.37 0.55 0.75 0.55 0.75 1.1 1.1 1.5 1.1 1.5 2.2 2.2 3 4 4 5.5 7.5 11 Maximum airflow (m3/h) 4750 2500 6300 6600 9000 10800 11300 12200 14500 16000 17500 20300 22500 24000 29000 32000 40500 44000 51000 63000 68000 Sound Approx. weight pressure level (Kg) dB(A) 77 60 69 70 70 71 72 73 75 74 78 78 79 81 83 84 84 89 91 93 94 22 20 32 35.5 32.5 34 35.5 35.5 39 59 63 73.5 76.8 85.2 95 100 106 118 132 159 181 HPX Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at an equivalent distance of twice the fan’s span plus the impeller’s diameter, with a minimum of 1.5 m. Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. Model 35-2-0.75 35-4-0.33 45-4-0.33 45-4-0.50 50-4-0.75 50-4-1 56-4-075 56-4-1 56-4-1.5 63-4-1.5 63-4-2 63 48 31 40 41 44 45 47 48 57 51 62 125 250500 1000200040008000 63 82 81 82 81 76 67 46 65 64 65 64 59 50 55 74 73 74 73 68 59 56 75 74 75 74 69 60 58 77 77 78 76 72 63 59 78 78 79 77 73 64 67 75 80 82 79 72 61 68 76 81 83 80 73 62 68 78 84 85 80 69 65 71 79 84 86 83 76 65 73 83 89 90 85 74 70 Model 71-4-1.5 74-4-2 71-4-3 80-4-3 80-4-4 80-4-5.5 90-4-5.5 90-4-7.5 100-4-10 100-4-15 63 55 56 65 60 61 68 67 69 73 74 125 250500 1000200040008000 75 83 88 90 87 80 69 76 84 89 91 88 81 70 76 86 92 93 88 77 73 80 88 93 95 92 85 74 81 89 94 96 93 86 75 79 89 95 96 91 80 76 88 95 100 103 99 92 81 90 97 102 105 101 94 83 93 101 106 108 105 98 87 94 102 107 109 106 99 88 Dimensions in mm A B A B HPX-35-2T-0.75 Model 425 395 355 DE HJN 380 606 10 8x45º HPX-71-4T-1.5 Model 810 770 710 DE HJN 550 1017 12 16x22º30’ HPX-35-4T-0.33 425 395 355 380 609 10 8x45º HPX-71-4T-2 810 770 710 550 1017 12 16x22º30’ HPX-45-4T-0.33 540 500 460 420 740 12 8x45º HPX-71-4T-3 810 770 710 550 1035 12 16x22º30’ HPX-45-4T-0.50 540 500 460 420 728 12 8x45º HPX-80-4T-3 900 860 800 600 1173 12 16x22º30’ HPX-50-4T-0.75 600 560 512 420 803 12 12x30º HPX-80-4T-4 900 860 800 600 1173 12 16x22º30’ HPX-50-4T-1 600 560 512 420 803 12 12x30º HPX-80-4T-5.5 900 860 800 600 1200 12 16x22º30’ HPX-56-4T-0.75 660 620 560 450 848 12 12x30º HPX-90-4T-5.5 1015 970 900 650 1320 15 16x22º30’ HPX-56-4T-1 660 620 560 450 848 12 12x30º HPX-90-4T-7.5 1015 970 900 650 1320 15 16x22º30’ HPX-56-4T-1.5 660 620 560 450 870 12 12x30º HPX-100-4T-10 1115 1070 1000 750 1483 15 16x22º30’ HPX-63-4T-1.5 730 690 640 500 950 12 12x30º HPX-100-4T-15 1115 1070 1000 750 1513 15 16x22º30’ HPX-63-4T-2 730 690 640 500 950 12 12x30º Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. 97 HPX Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. Accessories See accessories section. INT 98 AR RFT/ RFM PANELS RT BTUB BAC PS S SI HBA HBA Forked tubular axial fans with motor outside the air flow free Forked tubular fans for moving air of up to 150ºC continuously and up to 200ºC sporadically. Fan: • Sheet steel tubular casing. • Impeller made from cast aluminium • Airflow direction from impeller to motor Motor: • Single-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors with ball bearings, IP-55 protection • Three-phase 230/400V.-50Hz. (up to 5.5CV.) and 400/690V.-50Hz. (power over 5.5CV.) • Working temperature: -25ºC.+ 150ºC. Finish: • Anticorrosive with heat-protection paint for working in hot environments On request: • Casing made from stainless steel • Hot galvanised finish • Special windings for different voltages and motors with PTC Order code HBA 63 Forked tubular axial fans with motor outside the air flow 4T Impeller diameter in cm. Number of motor poles 4=1400 r/min. 50 Hz T=Three-phase Technical characteristics Model Speed Maximum admissible current (A) 230V 400V (r/min) HBA-31-2T HBA-31-2M HBA-31-4T HBA-31-4M HBA-40-2T HBA-40-2M HBA-40-4T HBA-45-2T HBA-50-4T HBA-63-4T HBA-71-4T HBA-71-6T HBA-80-6T HBA-100-6T 2760 2810 1350 1370 2860 2820 1370 2900 1410 1400 1440 900 945 945 2.57 3.49 1.66 2.00 4.20 6.51 2.02 10.18 3.10 4.03 14.10 2.99 4.88 4.88 Installed power (kW) 1.49 - 0.96 - 2.40 - 1.17 5.88 1.79 2.32 8.12 1.73 2.82 2.82 Maximum airflow (m3/h) 0.55 0.55 0.25 0.25 1.10 1.10 0.37 3.00 0.75 1.10 4.00 0.55 1.10 1.10 2900 2900 1600 1600 6200 6200 3200 8550 6750 11150 15850 11200 14900 21700 Sound Approx. weight pressure level (Kg) dB(A) 77 77 66 66 82 82 75 84 76 77 79 74 77 80 25 26 24 25 45 46 40 57 73 91 164 140 190 260 Accessories See accessories section. INT AR RFT/ RFM PANELS RT BTUB BAC PS S SI 99 HBA Dimensions in mm HBA-31...50 HBA-63...100 Model HBA-31 HBA-40 HBA-45 HBA-50 HBA-63 HBA-71 HBA-80 HBA-100 ØA ØB ØD 385 355 308 490 450 410 540 500 460 600 560 514 730 690 640 810 770 710 900 860 800 1115 1070 1000 EØJ M N 460 10 4x90º 45º 580 12 8x45º 22’5º 640 12 8x45º 22’5º 730 12 12x30º 15º 730 12 12x30º 15º 770 12 16x22’5º 11’25º 830 12 16x22’5º 11’25º 1270 15 16x22’5º 11’25º Characteristic curves Q = Airflow in m3/h, m3/s and cfm. 2 Poles=3000 r/min 6 Poles=1000 r/min 100 Pe= Static pressure in mmH2O, Pa and inwg. 4 Poles=1500 r/min HPX/SEC HPX/SEC Fans designed with the most advanced technology and experience to withstand extreme working conditions in ovens, driers and other applications with temperature and humidity free Fan: • Thick long casing with sheet steel twist-lock cap. • Impellers made from cast aluminium • High-quality bearings with grease for high temperatures • Bearing support with grease cups • External grease cups in fan casing • Airflow direction from motor to impeller Motor: • Single-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors, with bearings, IP55 protection. • Single-phase 230V -50Hz. and three-phase 230/400V.50Hz. (up to 5.5CV.) and 400/690V.-50Hz. (power over 5.5CV.) • Working temperature: -25ºC.+ 150ºC. Finish: • Anticorrosive in heat-resistant paint On request: • Airflow direction from impeller to motor • 100% reversible impellers. • Special windings for different voltages • ATEX Certification, category 2 (see HPX/ ATEX series) Order code HPX/SEC Fans to withstand extreme working conditions in ovens and driers 63 4T Impeller diameter in cm. 2 Number of motor poles 4=1400 r/min. 50 Hz T=Three-phase Power motor (c.v) Technical characteristics Model Speed HPX/SEC-63-4T-2 HPX/SEC-71-4T-2 HPX/SEC-71-4T-3 HPX/SEC-80-4T-4 HPX/SEC-80-4T-5.5 HPX/SEC-90-4T-7.5 HPX/SEC-90-4T-10 HPX/SEC-100-4T-10 HPX/SEC-100-4T-15 (r/min) Maximum admissible current (A) 230V 400V 690V 1450 5.96 1350 5.96 1450 8.36 1350 10.96 1450 14.10 1400 1400 1450 1450 3.44 3.44 4.83 6.33 8.12 11.60 6.72 14.20 8.20 14.20 8.20 20.20 11.60 Installed power (kW) 1.50 1.50 2.20 3.00 4.00 5.50 7.50 7.50 11.00 Maximum airflow (m3/h) 17500 22500 24000 32000 40500 51000 54700 63000 68000 Sound Approx. weight pressure level (Kg) dB(A) 78 79 81 84 84 91 92 93 94 68.1 84.5 91.5 107.0 116.0 132.5 145.5 148.5 191.5 Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at an equivalent distance of twice the fan’s span plus the impeller’s diameter, with a minimum of 1.5 m. Model HPX/SEC-63-4T-2 HPX/SEC-71-4T-2 HPX/SEC-71-4T-3 HPX/SEC-80-4T-4 HPX/SEC-80-4T-5.5 Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. 631252505001000 2000 4000 8000 62 73 83 89 90 85 74 70 56 76 84 89 91 88 81 70 65 76 86 92 93 88 77 73 61 81 89 94 96 93 86 75 68 79 89 95 96 91 80 76 Model HPX/SEC-90-4T-7.5 HPX/SEC-90-4T-10 HPX/SEC-100-4T-10 HPX/SEC-100-4T-15 631252505001000 2000 4000 8000 69 90 97 102 105 101 94 83 70 91 98 103 106 102 95 84 73 93 100 106 108 105 98 87 74 94 101 107 109 106 99 88 101 HPX/SEC Dimensions in mm Model HPX/SEC-63-4T-2 HPX/SEC-71-4T-2 HPX/SEC-71-4T-3 HPX/SEC-80-4T-4 HPX/SEC-80-4T-5,5 HPX/SEC-90-4T-7,5 HPX/SEC-90-4T-10 HPX/SEC-100-4T-10 HPX/SEC-100-4T-15 ØA ØB ØD E HØJ N 730 690 640 500 943 12 12x30º 810 770 710 550 1022 12 16x22º30’ 810 770 710 550 1048 12 16x22º30’ 900 860 800 600 1164,5 12 16x22º30’ 900 860 800 600 1185,5 13 16x22º30’ 1015 970 900 650 1338 15 16x22º30’ 1015 970 900 650 1338 15 16x22º30’ 1115 1070 1000 750 1453 15 16x22º30’ 1115 1070 1000 750 1525 15 16x22º30’ Characteristic curves See HPX series characteristic curves Accessories See accessories section. INT 102 AR RFT/ RFM PANELS RT BTUB BAC PS S SI HCH/SEC HCH/SEC free Fans designed with the most advanced technology and experience to withstand extreme working conditions in wood and ceramic driers 65ºC. 90ºC. 135ºC. Fan: • Sheet steel bracket or stainless steel AISI304 depending on the version • Impeller made from cast aluminium • Airflow direction from motor to impeller Motor version 65ºC 100%HR: • Class F motors with ball bearings, especially designed for temperature, IP-55 protection • Motors with forced ventilation • Three-phase 230/400V.50Hz. (up to 5.5CV.) and 400/690V.-50Hz. (power over 5.5CV.) • Working temperature: -10ºC.+ 65ºC. and 100% Motor version 90ºC. 100% RH: • Class H motors with ball bearings, especially designed for high temperature, IP-55 protection • Closed motors, without ventilation • Three-phase 230/400V.-50Hz. (up to 4CV.) and 400/690V.-50Hz. (power over 4CV.) • Working temperature: -10ºC.+ 90ºC. and 100% relative humidity • Axle and screws in STAINLESS STEEL • Closed motors, without ventilation • Three-phase 230/400V.50Hz. (up to 5.5CV.) and 400/690V.-50Hz. (power over 5.5CV.) • Working temperature: -10ºC.+ 135ºC. and 100% relative humidity Finish: • Anticorrosive finish in polyester resin, polymerised at 190ºC, after alkaline degreasing and phosphate-free pre-treatment. • STAINLESS STEEL version with blast finish On request: • Any HCH Series model may be converted into HCH/SEC • Airflow direction from impeller to motor • 100% reversible impellers. • Special windings for different voltages • Support ring in AISI-316 Motor version 135ºC. 100% RH: • Class H motors with ball bearings, especially designed for high temperature, IP-55 protection • Cast iron motor support shields Order code HCH/SEC Fans designed to withstand extreme working conditions in wood and ceramic driers 63 4T Impeller diameter Number of motor poles in cm. 4=1400 r/min. 50 Hz 1,5 65º INOX T=Three-phase Power motor (c.v) Max. working temperature 65ºC. 90ºC. 135ºC. Made from in stainless version Technical characteristics Model HCH/SEC-63-4T-1,5 HCH/SEC-63-4T-2 HCH/SEC-63-4T-3 HCH/SEC-63-4T-4 HCH/SEC-71-4T-1,5 HCH/SEC-71-4T-2 HCH/SEC-71-4T-3 HCH/SEC-71-4T-4 HCH/SEC-80-4T-3 HCH/SEC-80-4T-4 HCH/SEC-80-4T-5,5 Speed (r/min) 1450 1450 1450 1450 1450 1450 1450 1450 1450 1450 1450 Maximum admissible current (A) 230V 400V 5,2 6,41 8,49 11,78 5,2 6,41 8,49 11,78 8,49 11,78 15,24 3 3,7 4,9 6,8 3 3,7 4,9 6,8 4,9 6,8 8,8 Installed power (kW) 1,1 1,5 2,2 3 1,1 1,5 2,2 3 2,2 3 4 Maximum airflow (m3/h) 17000 18900 22100 25400 19750 21100 23950 29400 28000 32700 37200 Sound pressure level dB(A) 74 75 76 77 78 79 81 82 82 83 84 Approx. weight (Kg) 65º 90º 135º 33 36 44 46 37 40 49 51 60 62 67 39 42 50 52 45 47 56 58 73 75 80 29 32 36 39 32 35 40 43 50 53 56 103 HCH/SEC Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at an equivalent distance of twice the fan’s span plus the impeller’s diameter, with a minimum of 1.5 m. Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. Model HCH/SEC-63-4T-1.5 HCH/SEC-63-4T-2 HCH/SEC-63-4T-3 HCH/SEC-63-4T-4 HCH/SEC-71-4T-1.5 HCH/SEC-71-4T-2 631252505001000 2000 4000 8000 51 71 79 84 86 83 76 65 52 72 80 85 87 84 77 66 53 73 81 86 88 85 78 67 54 74 82 87 89 86 79 68 55 75 83 88 90 87 80 69 56 76 84 89 91 88 81 70 Model HCH/SEC-71-4T-3 HCH/SEC-71-4T-4 HCH/SEC-80-4T-3 HCH/SEC-80-4T-4 HCH/SEC-80-4T-5.5 631252505001000 2000 4000 8000 58 78 86 91 93 90 83 72 59 79 87 92 94 91 84 73 59 79 87 92 94 91 84 73 60 80 88 93 95 92 85 74 61 81 89 94 96 93 86 75 Dimensions in mm Detail: Drilled in the reversible version Manufactured on request only. E Model ØAØBØCØD1,5 2 3 45,5 HCH/SEC-63-4-65º 730 690 645 640 325 355 405 405 - 150 12 12 X 30º HCH/SEC-63-4-90º 730 690 645 640 305 330 360 360 - 150 12 12 X 30º HCH/SEC-63-4-135º 730 690 645 640 343 343 370 370 - 150 12 12 X 30º HCH/SEC-71-4-65º 810 770 715 710 330 350 415 415 - 150 12 16 X 22º30’ HCH/SEC-71-4-90º 810 770 715 710 302 322 367 367 - 150 12 16 X 22º30’ HCH/SEC-71-4-135º 810 770 715 710 358 358 370 370 - 150 12 16 X 22º30’ HCH/SEC-80-4-65º 900 860 805 800 - - 425 425 445 180 12 16 X 22º30’ HCH/SEC-80-4-90º 900 860 805 800 - - 375 375 390 180 12 16 X 22º30’ HCH/SEC-80-4-135º 900 860 805 800 - - 390 390 390 180 12 16 X 22º30’ Characteristic curves See HCH series characteristic curves Accessories See accessories section. INT 104 AR RFT/ RFM PANELS R RI F ØJ N VAM VAM VAC VAC VAM: Axial fans with galvanised frame and IP65 motor VAC: Axial fans for ducts with IP65 motor Wall-mounted axial fans specially designed for use in farms and corrosive environments. Fan: • Airflow direction from motor to impeller • Impeller in polyamide 6 reinforced with fibre glass • VAM: Support frame in hot galvanised sheet steel • VAM: Protection guard, meets UNE 100250 standard • VAC: Hot-rolled galvanised steel construction Motor: • Class F motors with incorporated thermal protector, ball bearings and IP65 protection • Single-phase 220-240V.-50Hz. and three-phase 220-240/380-415V.-50Hz. • Working temperature: -25ºC.+ 60ºC., 4-6 poles motors and -25ºC.+ 45ºC. Finish: • Hot galvanised anticorrosive VAM VAC Order code VAM 35 VAM: Galvanised axial fans VAC: Axial fans for ducts Technical characteristics Model VAM-35 T4 VAM-35 M4 VAM-40 T4 VAM-40 M4 VAM-45 T4 VAM-45 M4 VAM-50 T4 VAM-50 M4 VAM-56 T6 VAM-56 M6 VAM-63 T6 VAM-63 M6 Speed (r/min) VAC-35 T4 VAC-35 M4 VAC-40 T4 VAC-40 M4 VAC-45 T4 VAC-45 M4 VAC-50 T4 VAC-50 M4 VAC-56 T6 VAC-56 M6 VAC-63 T6 VAC-63 M6 1340 1340 1450 1420 1440 1360 1400 1370 915 915 905 905 T4 Impeller diameter Number of motor poles in cm. 2=2900 r/min. 50 Hz 4=1400 r/min. 50 Hz 6=750 r/min. 50 Hz Current to free airflow (A) 220V- 400V 380V-415V 0.74 0.43 0.98 2.10 1.20 1.55 2.10 1.20 1.85 2.15 1.25 2.30 1.73 1.00 2.12 2.06 1.19 2.70 Abs. power free airflow (W) 155 160 185 260 300 315 390 430 325 450 405 540 M=Single-phase T=Three-phase Maximum airflow (m3/h) 3500 3500 4000 4000 5810 5810 7300 7300 8250 8250 12050 12050 Sound level dB(A) 58 58 60 60 64 64 69 69 62 62 65 65 Approx. weight (Kg) VAM VAC 7.1 7.1 10.6 10.6 11 11 13 13 17 17 20 20 4.2 4.2 8.5 8.5 9 9 11 11 15 15 18 18 Erp. BEP (best efficiency point) characteristics MC EC VSD SR Model MC 35 T4 35 M4 40 T4 45 T4 45 M4 50 T4 50 M4 56 T6 63 T6 A A A A A A A A C ηe[%] Efficiency N Degree of efficiency [kW] Electrical power [m3/h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship EC VSD SR S S S S S S S S S NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 ηe[%] 28.3% 26.1% 26.3% 33.0% 30.9% 32.9% 29.0% 27.7% 28.5% N (kW) (m3/h) (mmH2O) (RPM) 39.9 37.4 37.5 42.7 40.4 41.8 37.6 37.5 37.6 0.145 0.158 0.172 0.292 0.314 0.387 0.438 0.283 0.373 2167 2191 2248 3719 3805 4894 4853 4469 6577 6.95 6.89 7.41 9.53 9.36 9.54 9.61 6.46 5.95 1418 1430 1476 1467 1439 1446 1434 964 957 105 VAM VAC Dimensions in mm VAM Model F A B ØC ØD Single-phaseThree-phaseG VAM-35 465 390 363 360 209 209 11 VAM-40 532 452 413 410 235 210 11 105 10.5 VAM-45 596 504 463 460 235 210 11 105 10.5 VAM-50 665 562 517 514 255 215 11 115 10.5 VAM-56 710 630 563 560 261 241 11 115 10.5 VAM-63 800 710 638 635 261 251 11 140 10.5 VAC H ØJ 86 10.5 F Single-phaseThree-phase ØJ Model ØD VAC-35 360 203 203 M8 VAC-40 410 231 206 M8 VAC-45 460 231 206 M8 VAC-50 520 251 211 M8 VAC-56 580 251 231 M8 VAC-63 650 251 421 M8 Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. Accessories See accessories section. INT 106 RM AR RFT/ RFM PANELS PL P RI RT BTUB BAC PS S SI HGI HGI Large-diameter axial fan for farms free Wall-mounted axial fans designed for large, low-speed airflows with automatic louvre opening system. Motor: • Single-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors, with bearings, IP55 protection. • Three-phase 230/400V.-50Hz • Working temperature: -25ºC.+ 50ºC Fan: • Sheet steel base plate. • Galvanised steel structure • Galvanised sheet steel impeller • Protection guard, meets UNE 100250 standard • Designed especially for use in farms and hothouses • Airflow direction from motor to impeller Finish: • Anticorrosive galvanized sheet steel On request: • Without shutter and with a protective grille on the impulsion side • Special windings for different voltages Order code HGI Large-diameter axial fan for farms 80 T Impeller diameter in cm. 0,5 T=Threephase Motor power (CV) Technical characteristics Model Speed (r/min) HGI-80-T-0.5 HGI-80-T-0.75 HGI-100-T-0.5 HGI-100-T-0.75 HGI-100-T-1 HGI-125-T-1 HGI-125-T-1.5 570 630 398 472 503 437 485 Maximum admissible current (A) 230V 400V 1.70 2.40 2.10 2.80 3.50 3.50 4.80 1.00 1.40 1.20 1.60 2.00 2.00 2.80 Installed power (kW) Maximum airflow (m3/h) 0.37 0.55 0.37 0.55 0.75 0.75 1.10 16000 18000 25000 29000 32000 38000 43000 Sound Approx. weight pressure level (Kg) dB(A) 63 65 62 65 66 69 72 48 49 63 64 66 87 90 Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at an equivalent distance of twice the fan’s span plus the impeller’s diameter, with a minimum of 1.5 m. Model HGI-80-T-0.5 HGI-80-T-0.75 HGI-100-T-0.5 HGI-100-T-0.75 Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. 631252505001000 2000 4000 8000 57 64 72 74 72 69 66 58 59 66 74 76 74 71 68 60 57 65 73 75 73 70 66 59 60 68 76 78 76 73 69 62 Model HGI-100-T-1 HGI-125-T-1 HGI-125-T-1.5 Characteristic curves Q = Airflow in m3/h, m3/s and cfm. and inwg. 631252505001000 2000 4000 8000 61 69 77 79 77 74 70 63 64 72 80 82 80 77 73 66 67 75 83 85 83 80 76 69 Dimensions in mm Pe= Static pressure in mmH2O, Pa Model A BC HGI-80 925 925 427 HGI-100 1125 1125 447 HGI-125 1375 1375 480 Accessories See accessories section. INT AR RFT/ RFM PANELS SI 107 OVERPRESSURE KIT OVERPRESSURE KIT The system of pressurisation of staircases, escape routes or of confinement makes it possible to control the airflow automatically and to maintain a differential pressure of 50 Pa in a single stage, according to standard UNE EN 12101-6-2006. STAIRWELL OVERPRESSURE KIT Three-phase equipment STAIRWELL OVERPRESSURE KIT • Stairwell overpressure kit made up of control panel (BOXPRES KIT) and outlet units (CJHCH or CJBD) , for the pressurisation of the stairwells and escape routes. Also available for single-phase equipment's NEOLINEO Y CJBC. OVERPRESSURE KIT WITH RESERVE FAN • Overpressure kit with reserve fan, made up of control panel (BOXPRES KIT II), which incorporates a system of automatic switching to keep the overpressure in the case of a stop by the main fan and TWIN or CJHCH/DUPLEX air outlet units with reserve fan. BOXPRES · Easy to install · Compact and self-sufficient solution · Preventive maintenance · Easy starting · Safe and functional installation STAIRWELL OVERPRESSURE KIT For single-phase equipment • The proper operation of the pressurisation systems depends not only on correct design but also on the proper regulation carried out by the system with the result that it is of vital importance to have calibrated and highly-precise regulation elements which make it possible to have the two situations in the case of fire, in a rapid and stable manner. • The BOXPRES control panel, apart from satisfying the most demanding requirements, simplifies the work of the installer to the greatest possible extent. OVERPRESSURE KIT WITH RESERVE FAN Includes: • Frequency varier programmed to 50 Pa • Differential pressure probe • Magneto thermal • Line LED and fault • Check button BOXPRES is a piece of equipment with all its interconnections made and tested • Ready to work and carry out its duties on the pressure control of the installation. • Possibility of checking the installation so as to prevent faults • Only the power cable, the impulsion fan and the fire signal should be connected. The panels for single-phase equipment include: • Voltage regulator programmed to 50 Pa • Differential pressure probe external to the equipment. Order code OVERPRESSURE KIT Kit sobrepresión: Overpressure set for staircases Kit sobrepresión II: Overpressure set with reserve fan 108 7.100 Maximum Airflow OVERPRESSURE KIT Technical characteristics Model Power Outlet Outlet unit Airflow (m3/h) KIT SOBREPRESION-1060-LED 230 Vac II 230 Vac II NEOLINEO-200 1060 KIT SOBREPRESION-2300-LED 230 Vac II 230 Vac II NEOLINEO-315 2300 KIT SOBREPRESION-2880-LED 230 Vac II 230 Vac II CJBC-2828-6M 1/3 2880 KIT SOBREPRESION-7100-LED 230 Vac II 230 Vac III CJHCH-45-4T-0.5 7100 KIT SOBREPRESION-7800-LED 230 Vac II 230 Vac III CJBD-3333-6T -1.5 7800 KIT SOBREPRESION-12900-LED 230 Vac II 230 Vac III CJHCH-56-4T-1 12900 KIT SOBREPRESION-17000-LED 230 Vac II 230 Vac III CJHCH-63-4T-1.5 17000 KIT SOBREPRESION-7100-BOX 400 Vac III 400 Vac III CJHCH-45-4T-0.5 7100 KIT SOBREPRESION-7800-BOX 400 Vac III 400 Vac III CJBD-3333-6T -1.5 7800 KIT SOBREPRESION-12900-BOX 400 Vac III 400 Vac III CJHCH-56-4T-1 12900 KIT SOBREPRESION-17000-BOX 400 Vac III 400 Vac III CJHCH-63-4T-1.5 17000 KIT SOBREPRESION II-6240-BOX KIT SOBREPRESION II-9520-BOX KIT SOBREPRESION II-12900-BOX KIT SOBREPRESION II-17000-BOX 400 Vac III 400 Vac III 400 Vac III 400 Vac III 400 Vac III 400 Vac III 400 Vac III 400 Vac III TWIN-12/12-6T-1.5 TWIN-15/15-6T-3 CJHCH/DUPLEX-56-4T-1-H CJHCH/DUPLEX-63-4T-1.5-H 6240 9520 12900 17000 Sound level irradiated * dB(A) 38 47 61 55 55 60 61 55 55 60 61 55 54 60 61 SONDA TPDA SI-PRESIÓN c/DISPLAY SONDA TPDA 984M.523 P04 SONDA TPDA 984M.523 P14 LED BOXPRES KIT-3A 230Vac BOXPRES KIT-10A 230Vac BOXPRES KIT-0.75KW 230Vac BOXPRES KIT-1.5KW 230Vac BOXPRES KIT-0.75KW 400Vac BOXPRES KIT-1.5KW 400Vac BOXPRES KIT-2.2KW 400Vac BOXPRES KIT II - 1.5KW 400Vac BOXPRES KIT II - 2.2KW 400Vac 230 Vac II 230 Vac II 230 Vac II 230 Vac II 400 Vac III 400 Vac III 400 Vac III 400 Vac III 400 Vac III 230 Vac II 230 Vac II 230 Vac III 230 Vac III 400 Vac III 400 Vac III 400 Vac III 400 Vac III 400 Vac III Dimensions in mm CJHCH Model CJBD ACD1 CJHCH-40/45/50 700 550 565 CJHCH-56/63 825 550 690 Model Equiv. A B CE D1xD2G1 L inches CJBD-3333 12/12 650 650 700 92 556X606 379 358 K 400 109 OVERPRESSURE KIT Dimensions in mm TWIN CJHCH/DUPLEX Model AB C TWIN-12/12 1103 1139 610 Model TWIN15/15 1279 1639 698 CJHCH/DUPLEX-56/63 NEOLINEO Model AB C D1 825 1650 550 690 CJBC A B C C1 C2øD E NEOLINEO-200 300 234.5 260.5 125.5 235 196 140 NEOLINEO-315 448 361.5 392.5 188.5 359 312 220.5 Model CJBC-2828-6M -1/3 A B H K LøO V v1 X x1 696 645 460 290 320 15 755 725 445 100 BOXPRESS KIT SOBREPRESIÓN Technical characteristics and measurements Model Power kW Voltage (V/Hz) Output (V/Hz) Output current (A) Size Measurements (L x W x D) BOXPRES KIT-3A 230Vac - 230 Vac II 230 Vac II 3 - 255 x 170 x 140 mm BOXPRES KIT-10A 230Vac - 230 Vac II 230 Vac II 10 - 255 x 170 x 140 mm BOXPRES KIT-0.75kW 230Vac 0.75 230 V II / 50Hz 230 V III / 50Hz 4.3 1 270 x 270 x 170 mm BOXPRES KIT-1.5kW 230Vac 1.5 230 V II / 50Hz 230 V III / 50Hz 7 1 270 x 270 x 170 mm BOXPRES KIT-0.75KW 400Vac 0.75 400 V III / 50Hz 400 V III / 50Hz 2.2 1 270 x 270 x 170 mm BOXPRES KIT-1.5KW 400Vac 1.5 400 V III / 50Hz 400 V III / 50Hz 4.1 1 270 x 270 x 170 mm BOXPRES KIT-2.2KW 400Vac 2.2 400 V III / 50Hz 400 V III / 50Hz 5.8 2 360 x 360 x 205 mm BOXPRES KIT-3A / KIT-10A Connection of power and motor Stuffing-box for cable input to equipment Size 1 M 20 x 1.5mm Connection of power and motor M 12 x 1.5mm Fire signal connection Regulator Pressure connection Probe Pressure connection 110 Stuffing-box for cable input to equipment Size 2 M 20 x 1.5mm Connection of power and motor M 12 x 1.5mm Fire signal connection Pressure connection OVERPRESSURE KIT BOXPRESS KIT SOBREPRESIÓN II For equipment with reserve fan. Technical characteristics and measurements Power kW Model BOXPRES KIT II - 1.5KW 400Vac BOXPRES KIT II - 2.2KW 400Vac 1.5 2.2 Voltage (V/Hz) Outlet (V/Hz) Output current (A) 400 V III / 50Hz 400 V III / 50Hz 400 V III / 50Hz 400 V III / 50Hz 4.1 5.4 Size Measurements (L x W x D) 1 2 270 x 270 x 170 mm 360 x 360 x 205 mm * Both motors never operate simultaneously Stuffing-box for cable input to equipment Size 1 M 20 x 1.5mm Connection of power and motor M 12 x 1.5mm Fire signal connection Pressure connection Stuffing-box for cable input to equipment Size 2 M 20 x 1.5mm Connection of power and motor M 12 x 1.5mm Fire signal connection Pressure connection Example of use Overpressure smoke control method; this system consists of pressurization by means of the injection of air in spaces which are used as escape routes for people in case of fire, such as stair wells, passageways, corridors, elevators, etc. Above all in densely occupied tall buildings. This method is based on smoke control by means of the speed of air and the artificial barrier which is created by excess air pressure over smoke, so that it cannot enter escape routes. 111 HT HT Axial roof fans with flat base Axial roof fans with plastic fibreglass-reinforced impeller, with a flat base to mount on the roof. Fan: • Sheet steel base plate. • Impellers in polyamide 6 reinforced with fibre glass • Bird guard • Sheet steel rain deflector hood with anticorrosive protection, except models 80,90,100 which come in polyester • Airflow direction from motor to impeller Motor: • Single-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors, with ball bearings and IP55 protection, except single-phase versions from size 45 to size 63, IP54 protection. • Single-phase 220-240V-50Hz. and three-phase 220-240V/380-415V-50Hz. (up to 5.5CV.) and 400/690V.-50Hz. (power over 5.5CV.) • Max. air temperature to transport: -25ºC+ 60ºC Finish: • Anticorrosive finish in polyester resin, polymerised at 190ºC, after alkaline degreasing and phosphate-free pre-treatment. On request: • Possibility of supply as IMPULSION FANS • AL version cast aluminium impellers. • Special windings for different voltages • ATEX certification, Category 2 Order code HT Axial roof fans with flat base 25 Impeller diameter in cm. 4T Number of motor poles 2=2900 r/min. 50 Hz 4=1400 r/min. 50 Hz 6=750 r/min. 50 Hz I BS M=Single-phase T=Three-phase I: Extraction fans A: Impulsion fans extraction BS: High base plate BSS: High base plate with silencer. Outlet Technical characteristics Model HT-25-4T HT-25-4M HT-31-4T HT-31-4M HT-35-4T HT-35-4M HT-40-4T HT-40-4M HT-45-4T HT-45-4M HT-50-4T HT-50-4M HT-56-4T HT-56-4M HT-56-6T HT-56-6M HT-63-4T HT-63-6T HT-63-6M HT-71-4T HT-71-6T 112 Speed (r/min) 1320 1380 1320 1370 1320 1370 1350 1370 1370 1400 1380 1350 1410 1410 900 900 1400 900 900 1430 900 Max. admissible current (A) 230V 400V 690V 0.65 0.38 0.65 0.65 0.38 0.83 0.65 0.38 0.83 1.66 0.96 2.00 2.02 1.17 2.76 2.92 1.69 4.40 3.10 1.79 5.05 1.51 0.87 2.07 4.03 2.32 2.24 1.30 2.69 5.96 3.44 2.99 1.73 Installed power (kW) 0.09 0.10 0.09 0.09 0.09 0.09 0.25 0.25 0.37 0.37 0.55 0.55 0.75 0.75 0.25 0.25 1.10 0.37 0.37 1.50 0.55 Maximum airflow (m3/h) 1080 1080 1800 1800 2600 2600 4600 4600 6500 6500 8500 8500 9800 9800 6600 6600 14000 9200 9200 18000 12200 Sound pressure level dB(A) Inlet Outlet 41 41 47 47 48 48 51 51 55 55 59 59 61 61 48 48 63 52 52 69 58 40 40 46 46 47 47 50 50 53 54 57 57 57 57 46 46 59 49 49 67 56 Approx. weight (Kg) 12.5 12.5 13.3 13.5 17.5 17.5 21.0 21.0 29.0 30.5 36.0 39.0 35.0 37.0 46.0 46.0 65.8 61.8 61.8 64.0 64.9 HT Technical characteristics Model Max. admissible current (A) 230V 400V 690V Speed (r/min) HT-71-6M HT-80-4T HT-80-6T HT-90-4T HT-90-6T HT-100-4T-7.5 HT-100-4T-10 HT-100-6T-2 HT-100-6T-3 HT-100-8T-1.5 HT-100-8T-2 900 3.84 1445 8.36 4.83 945 4.88 2.82 1445 10.96 6.33 955 6.42 3.71 1440 11.60 6.72 1455 14.20 8.20 955 6.42 3.71 955 9.30 5.30 705 5.63 3.25 705 7.10 4.10 Installed power (kW) 0.55 2.20 1.10 3.00 1.50 5.50 7.50 1.50 2.20 1.10 1.50 Maximum airflow (m3/h) 12200 26200 18000 31500 21200 37000 44000 25000 28200 19050 21100 Sound pressure level dB(A) Inlet Outlet 58 73 64 77 68 80 84 71 75 64 66 56 70 61 74 65 77 81 68 72 61 63 Approx. weight (Kg) 64.9 87.8 81.8 94.0 91.0 114.0 125.0 102.0 106.0 103.0 114.0 Erp. BEP (best efficiency point) characteristics MC EC VSD SR Model HT-25-4T HT-25-4M HT-31-4T HT-31-4M HT-35-4T HT-35-4M HT-40-4T HT-40-4M HT-45-4T HT-45-4M HT-50-4T HT-50-4M HT-56-4T HT-56-4M HT-56-6T HT-56-6M HT-63-4T HT-63-6T HT-63-6M HT-71-4T HT-71-6T HT-71-6M HT-80-4T HT-80-6T HT-90-4T HT-90-6T HT-100-4T-7.5 HT-100-4T-10 HT-100-6T-2 HT-100-6T-3 HT-100-8T-1.5 HT-100-8T-2 ηe[%] Efficiency N Degree of efficiency [kW] Electrical power 3 [m /h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship MC - - - - A A A A A A A A A A A A C C C C C C C C C C C C C C C C EC VSD SR - - - - S S S S S S S S S S S S S S S S S S S S S S S S S S S S - - - - NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO - - - - 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 ηe[%] - - - - 27.4% 25.6% 32.0% 28.2% 33.4% 29.6% 29.5% 28.6% 33.2% 31.4% 31.4% 26.6% 45.3% 32.7% 32.2% 50.1% 35.7% 33.6% 56.7% 46.7% 58.1% 50.9% 51.0% 47.5% 47.5% 47.3% 47.6% 42.7% N (kW) (m3/h) - - - - 39.3 37.4 41.7 37.5 41.8 37.6 37.0 36.0 40.3 38.4 41.7 36.3 51.1 41.1 40.6 55.3 43.0 40.7 60.7 52.1 61.1 55.7 52.4 48.1 52.5 51.1 52.9 47.2 0.099 0.102 0.103 0.111 0.128 0.137 0.289 0.329 0.475 0.538 0.649 0.668 0.759 0.796 0.237 0.293 1.179 0.474 0.482 1.508 0.710 0.755 2.309 1.380 3.362 1.777 5.965 7.982 1.619 2.461 1.452 1.923 586 566 1013 1004 1857 1851 3401 3332 4228 4257 3716 3673 6599 6344 3564 4104 10593 6417 6339 13256 8036 7945 16178 15312 20308 18106 27281 36164 19961 23849 19345 20901 (mmH2O) 3.45 3.59 4.06 4.09 6.94 6.96 10.00 10.23 13.80 13.73 18.91 19.10 14.03 14.48 7.69 6.98 18.50 8.88 8.99 20.95 11.60 11.73 29.73 15.45 35.36 18.37 40.95 38.48 14.14 17.92 13.11 14.42 (RPM) 1358 1386 1397 1418 1400 1425 1396 1401 1392 1410 1406 1422 1423 1435 919 933 1412 921 915 1442 913 908 1451 946 1447 957 1443 1458 953 959 707 706 Best efficiency point data of the internal fan 113 HT Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at a distance of 6 m. Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. Model 25 31 35 40 45 50 56-4 56-6 63-4 63-6 71-4 71-6 80-4 80-6 90-4 90-6 100-4-7.5 100-4-10 100-6-2 100-6-3 100-8-1.5 100-8-2 631252505001000 2000 4000 8000 27 37 54 54 62 58 51 42 33 43 60 60 68 64 57 48 34 44 61 61 69 65 58 49 28 45 57 65 70 70 66 59 32 49 61 69 74 74 70 63 36 53 65 73 78 78 74 67 38 55 67 75 80 80 76 69 25 42 54 62 67 67 63 56 40 57 69 77 82 82 78 71 29 46 58 66 71 71 67 60 46 63 75 83 88 88 84 77 35 52 64 72 77 77 73 66 57 78 85 90 93 89 82 71 48 69 76 81 84 80 73 62 61 82 89 94 97 93 86 75 52 73 80 85 88 84 77 66 64 85 92 97 100 96 89 78 68 89 96 101 104 100 93 82 55 76 83 88 91 87 80 69 59 80 87 92 95 91 84 73 48 69 76 81 84 80 73 62 50 71 78 83 86 82 75 64 Model 25 31 35 40 45 50 56-4 56-6 63-4 63-6 71-4 71-6 80-4 80-6 90-4 90-6 100-4-7.5 100-4-10 100-6-2 100-6-3 100-8-1.5 100-8-2 Dimensions in mm Model HT-25 HT-31 HT-35 HT-40 HT-45-4T HT-45-4M HT-50-4T HT-50-4M HT-56-4T HT-56-4M HT-56-6 HT-63-4 HT-63-6 HT-71-4T HT-71-6 HT-80-4 HT-80-6 HT-90-4 HT-90-6 HT-100-4T HT-100-6T-2 HT-100-6T-3 HT-100-8T-1.5 HT-100-8T-2 114 ABC DEØF GH ØI ØJ 400 176 44 40 140 620 450 360 12 346 423 176 67 40 140 620 500 410 12 416 472 228 64 40 140 770 560 450 12 486 478 228 82 40 128 770 630 530 12 536 550 266 88 50 146 960 710 590 12 596 512 266 88 50 108 960 710 590 12 596 575 296 83 50 146 1090 800 680 12 676 558 296 83 50 129 1090 800 680 12 676 607 296 117 40 154 1090 900 750 14 758 590 296 117 40 137 1090 900 750 14 758 589 296 117 40 136 1090 900 750 14 758 714 357 136 40 182 1285 1000 850 14 735 667 357 136 40 135 1285 1000 850 14 735 740 357 166 40 178 1285 1000 850 14 815 689 357 166 40 178 1285 1000 850 14 815 840 357 244 50 189 1285 1150 1000 14 905 804 357 244 50 153 1285 1150 1000 14 905 892 440 213 50 189 1580 1150 1000 14 1020 896 440 213 50 193 1580 1150 1000 14 1020 997 440 284 50 223 1580 1250 1100 14 1120 940 440 284 50 166 1580 1250 1100 14 1120 957 440 284 50 183 1580 1250 1100 14 1120 940 440 284 50 166 1580 1250 1100 14 1120 957 440 284 50 183 1580 1250 1100 14 1120 631252505001000 2000 4000 8000 26 36 53 53 61 57 50 41 32 42 59 59 67 63 56 47 33 43 60 60 68 64 57 48 27 44 56 64 69 69 65 58 30 47 59 67 72 72 68 61 34 51 63 71 76 76 72 65 34 51 63 71 76 76 72 65 23 40 52 60 65 65 61 54 36 53 65 73 78 78 74 67 26 43 55 63 68 68 64 57 44 61 73 81 86 86 82 75 33 50 62 70 75 75 71 64 54 75 82 87 90 86 79 68 45 66 73 78 81 77 70 59 58 79 86 91 94 90 83 72 49 70 77 82 85 81 74 63 61 82 89 94 97 93 86 75 65 86 93 98 101 97 90 79 52 73 80 85 88 84 77 66 56 77 84 89 92 88 81 70 45 66 73 78 81 77 70 59 47 68 75 80 83 79 72 61 HT Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. 4 T/4M=1500 r/min 6T/6M=1000 r/min 4 T/4M=1500 r/min 8T=750 r/min Accessories See accessories section. INT RM AR RFT/ RFM PANELS BTUB MS PA OP S SI BS 115 HTTI HTTI Axial roof fans with sloping base Axial roof fans adapted to the roof slope, with built-in safety switch. Fan: • Galvanised sheet steel base plate. • Impellers in polyamide 6 reinforced with fibre glass • Rain deflector hood • Airflow direction from motor to impeller Motor: • Single-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors, with bearings, IP55 protection. • Three-phase 230/400V.-50Hz. (up to 5.5CV.) and 400/690V.-50Hz. (power over 5.5CV.) • Max. air temperature to transport: -25ºC+ 60ºC Finish: • Anticorrosive galvanized sheet steel On request: • All the angles and base plate measurements required (max. length 2m) • Made from stainless steel sheet • Special windings for different voltages • ATEX certification, Category 2 Order code HTTI Axial roof fans with sloping base 45 4T Impeller diameter in cm. Number of motor poles 4=1400 r/min. 50 Hz 6=750 r/min. 50 Hz T=Three-phase Technical characteristics Model HTTI-45-4T HTTI-50-4T HTTI-50-6T HTTI-56-4T HTTI-56-6T HTTI-63-4T HTTI-63-6T HTTI-71-4T HTTI-71-6T HTTI-80-4T HTTI-80-6T HTTI-90-4T HTTI-90-6T HTTI-100-4T HTTI-100-6T 116 Speed (r/min) Max. admissible current (A) 230V 400V 690V 1370 2.02 1380 2.92 900 2.24 1400 4.03 900 2.24 1400 4.03 900 2.24 1430 5.96 900 2.99 1445 10.96 945 4.88 1440 14.10 955 6.42 1455 955 9.30 1.17 1.69 1.30 2.32 1.30 2.32 1.30 3.44 1.73 6.33 2.82 8.12 3.71 14.20 8.20 5.30 Installed power (kW) 0.37 0.55 0.37 1.10 0.37 1.10 0.37 1.50 0.55 3.00 1.10 4.00 1.50 7.50 2.20 Maximum airflow (m3/h) 6570 9200 5680 11700 7560 14800 11160 18900 13500 33300 23400 41850 30870 56700 34200 Sound pressure level dB(A) 66 69 59 72 61 74 64 78 67 83 72 89 77 93 82 Approx. weight (Kg) 45.7 56.0 59.5 64.4 64.0 70.9 70.0 82.0 78.5 114.4 103.8 137.0 129.0 181.0 149.8 HTTI Erp. BEP (best efficiency point) characteristics MC EC VSD SR Facts internal fan. Model HTTI-45-4T HTTI-50-4T HTTI-56-4T HTTI-63-4T HTTI-63-6T HTTI-71-4T HTTI-71-6T HTTI-80-4T HTTI-80-6T HTTI-90-4T HTTI-90-6T HTTI-100-4T HTTI-100-6T ηe[%] Efficiency N Degree of efficiency [kW] Electrical power 3 [m /h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship MC A A A C C C C C C C C C C EC VSD SR S S S S S S S S S S S S S NO NO NO NO NO NO NO NO NO NO NO NO NO 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 ηe[%] 33.4% 29.5% 31.3% 45.3% 32.7% 50.1% 35.7% 54.0% 46.7% 56.2% 50.9% 47.5% 47.3% N (kW) (m3/h) 41.8 37.0 37.7 51.1 41.1 55.3 43.0 57.1 52.1 58.5 55.7 48.1 51.1 0.475 0.649 0.973 1.179 0.474 1.508 0.710 3.246 1.380 4.306 1.777 7.982 2.461 4228 3716 7130 10593 6417 13256 8036 19442 15312 24635 18106 36164 23849 (mmH2O) 13.80 18.91 15.69 18.50 8.88 20.95 11.60 33.11 15.45 36.06 18.37 38.48 17.92 (RPM) 1392 1406 1427 1412 921 1442 913 1449 946 1444 957 1458 959 Best efficiency point data of the internal fan Dimensions in mm WATERPROOF INCLINATION: % or Hx100 % Distance between maximum belts 2m Model HTTI-45-4T HTTI-50-4T HTTI-50-6T HTTI-56-4T HTTI-56-6T HTTI-63-4T HTTI-63-6T HTTI-71-4T HTTI-71-6T HTTI-80-4T HTTI-80-6T HTTI-90-4T HTTI-90-6T HTTI-100-4T HTTI-100-6T ABCD ØFGH ØI 780 130 200 250 850 730 520 470 800 150 200 250 950 780 570 520 800 150 200 250 950 780 570 520 800 150 200 250 1050 830 620 570 800 150 200 250 1050 830 620 570 850 180 200 250 1125 910 700 650 850 180 200 250 1125 910 700 650 900 200 230 300 1250 990 780 730 900 200 230 300 1250 990 780 730 1100 250 310 330 1400 1080 870 820 1100 250 310 330 1400 1080 870 820 1150 300 310 330 1500 1080 970 920 1150 300 310 330 1500 1080 970 920 1200 350 310 330 1600 1280 1070 1020 1200 350 310 330 1600 1280 1070 1020 117 HTTI Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. 4T=1500 r/min 6T=1000 r/min Accessories See accessories section. INT 118 RM AR RFT/ RFM PANELS OP S SI HTTAL HTTAL Mixed roof extractors (eolic + dynamic), with adjustable base Roof fan operating by means of natural convection (due to depression of hot air and the Venturi effect) and with an additional fan to improve the performance. + Fan • Adjustable base for roof slopes between 0 and 30% • Built in sheet aluminium to prevent corrosion. • Impeller made from polyamide Motor: • Single-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors, with bearings, IP55 protection. • Three-phase 230/400V – 50 Hz • Max. air temperature to transport: - 25ºC y +60ºC HTTAL Order code HTTAL 56 4T Impeller diameter (cm) Mixed roof fan with adjustable base Number of motor poles 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz T= Three-phase Technical characteristics Model Maximum admissible current (A) 230V 400V Speed (r/min) HTTAL-56-4T HTTAL-56-6T HTTAL-71-4T HTTAL-71-6T 1400 900 1430 900 4.03 2.24 5.96 2.99 2.32 1.30 3.44 1.73 Installed power (kW) Maximum airflow (m3/h) 1.10 0.37 1.50 0.55 11700 7560 18900 13500 Sound pressure Approx. weight (Kg) level dB(A) 72 61 78 61 44.0 43.6 56.0 55.0 Erp. BEP (best efficiency point) characteristics MC EC VSD SR Model HTTAL-56-4T HTTAL-71-4T HTTAL-71-6T ηe[%] Efficiency N Degree of efficiency [kW] Electrical power 3 [m /h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship MC A C C EC VSD SR S S S NO NO NO 1.00 1.00 1.00 ηe[%] 31.3% 50.1% 35.7% N (kW) (m3/h) 37.7 55.3 43.0 0.973 1.508 0.710 7130 13256 8036 (mmH2O) 15.69 20.95 11.60 (RPM) 1427 1442 913 Best efficiency point data of the internal fan 119 HTTAL Dimensions in mm Model AB ØC HTTAL-56-4T 360 920x920 570 HTTAL-56-6T 360 920x920 570 HTTAL-71-4T 460 1150x1150 730 HTTAL-71-6T 460 1150x1150 730 Characteristic Curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. Accessories See accessories section. INT 120 RM AR RFT/ RFM PANELS OP S SI CHT CHT CVT CVT 400ºC/2h centrifugal roof fans with horizontal or vertical outlet air CHT: 400ºC/2h centrifugal roof fans with horizontal outlet air, hood in aluminium 0370-CPD-0897 CVT: 400ºC/2h centrifugal roof fans with vertical outlet air, hood in aluminium Fan: • Galvanised sheet steel base plate. • Impeller with backward-curved blades made from galvanised sheet steel • Bird guard • Aluminium rain deflector hood • Approval according to Standard EN-12101-3-2002, certification No.: 0370-CPD-0897 Motor: • Single-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW. • Class F motors, with ball bearings and IP55 protection, except single-phase versions, IP54 protection, one- or twospeed depending on the model • Single-phase 230V.-50Hz., and threephase 230/400V.-50Hz. • Max. air temperature to transport: -25ºC.+ 120ºC. CHT Finish: • Anticorrosive galvanized sheet steel and aluminium On request: • Special windings for different voltages, • ATEX certification, Category 3 CVT Brackets that aid mounting on the roof Order code CHT CHT: 400ºC/2h centrifugal roof fans with horizontal outlet air 200 CVT: 400ºC/2h centrifugal roof fans with vertical outlet air Impeller size 4T BS T=Three-phase Number of motor poles 2=2900 r/min. 50 Hz 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz 8=750 r/min. 50 Hz 12=500 r/min. 50 Hz BS: High base plate BSS: High base plate with silencer. Technical characteristics Model Speed (r/min) Maximum admissible current (A) 230V 400V Installed power (kW) CHT CVT 200-4T 1350 1.66 0.96 0.25 CHT CVT 200-4M 1380 0.65 0.25 Maximum airflow (m3/h) Sound level dB(A) Inlet Outlet Approx. weight (Kg) 1450 37 43 25 1450 37 43 25 CHT CVT 225-4T 1350 1.66 0.96 0.25 2100 41 47 25 CHT CVT 225-4M 1380 0.95 0.25 2100 41 47 25 CHT CVT 225-6T 900 1.51 0.87 0.25 1400 30 36 26 CHT CVT 225-6M 890 0.50 0.25 1400 30 36 26 CHT CVT 250-4T 1350 1.66 0.96 0.25 3100 45 50 34 CHT CVT 250-4M 1380 1.35 0.25 3100 45 50 34 CHT CVT 250-6T 900 1.51 0.87 0.25 2000 33 40 35 CHT CVT 250-6M 890 0.65 0.25 2000 33 40 35 CHT CVT 315-4T CHT CVT 315-4/8T 2.92 1.69 0.55 4950 48 54 39 1450/720 1380 1.70 / 0.80 0.55 / 0.19 4950 / 2475 48 / 33 54 / 39 40 121 CHT CVT Technical characteristics Model Speed Maximum admissible current (A) 230V (r/min) CHT CVT 315-4M 1380 CHT CVT 315-6T 900 CHT CVT 315-6M 910 CHT CVT 400-4T 1410 CHT CVT 400-4/8T CHT CVT 400-4M Installed power (kW) 400V 3.30 0.55 2.24 0.37 1.30 Maximum airflow (m3/h) Sound level dB(A) Inlet Outlet Approx. weight (Kg) 4950 48 54 39 3200 37 43 39 0.95 0.37 3200 37 43 39 3.10 1.79 0.75 7000 55 61 57 1430 / 710 2.00 / 0.90 0.75 / 0.20 7000 / 3500 55 / 40 61 / 46 58 4.40 0.75 7000 55 61 57 1380 CHT CVT 400-6T 900 2.24 1.30 0.37 4500 44 50 56 CHT CVT 400-6M 910 1.80 0.37 4500 44 50 56 CHT CVT 450-4T 1430 CHT CVT 450-4/8T CHT CVT 450-6T 5.96 3.44 1.50 10200 59 64 66 1420 / 700 3.50 / 1.50 1.50 /0.37 10200 / 5100 59 / 43 64 / 49 66 900 CHT CVT 450-6/12T 2.24 1.30 0.37 6900 47 54 59 930 / 450 1.60 / 0.65 0.55 / 0.09 6900 / 3450 47 / 32 54 / 39 63 CHT CVT 450-6M 910 2.00 0.37 6900 47 54 59 CHT CVT 500-6T 945 4.88 2.82 1.10 12000 51 57 103 950 / 470 3.00 /1.15 1.10 / 0.18 12000 / 6000 51 / 36 57 / 42 110 2.04 0.55 8900 44 50 103 CHT CVT 500-6/12T CHT CVT 500-8T CHT CVT 560-6T CHT CVT 560-6/12T 695 3.53 955 9.30 5.30 2.20 17300 54 61 126 940 / 470 5.60 / 2.20 2.20 / 0.37 17300 / 8650 54 / 39 61 / 46 120 CHT CVT 560-8T 705 5.63 3.25 1.10 12900 46 53 110 CHT CVT 630-6T 960 16.50 9.46 4.00 24700 58 64 166 4.00 / 0.65 24700 / 12350 58 / 43 64 / 49 161 50 57 148 CHT CVT 630-6/12T CHT CVT 630-8T 970 / 480 11.00 / 4.00 705 7.10 4.10 1.50 18400 (1) The sound level values are measurements of pressure in dB(A) at a distance of 6 m and at 2/3 of the maximum airflow (2/3 Qmax.) Erp. BEP (best efficiency point) characteristics MC EC VSD SR Model 200-4T 200-4M 225-4T 225-4M 225-6T 225-6M 250-4T 250-4M 250-6T 250-6M 315-4T 315-4/8T 315-4M 315-6T 315-6M 400-4T 400-4/8T 400-4M 400-6T 400-6M 450-4T 450-4/8T 450-6 450-6/12T 450-6M 500-6T 500-6/12T 500-8T 560-6T 560-6/12T 560-8T 630-6T 630-6/12T 630-8T MC - - C C - - C C - C C C C C C C C C C C C C C C C C C C C C C C C C ηe[%] Efficiency N Degree of efficiency [kW] Electrical power 3 [m /h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship EC VSD SR - - S S - - S S - S S S S S S S S S S S S S S S S S S S S S S S S S - - NO NO - - NO NO - NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO - - 1.00 1.00 - - 1.00 1.00 - 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.00 1.01 1.01 1.00 ηe[%] - - 41.2% 42.0% - - 45.0% 43.5% - 40.6% 50.4% 50.2% 48.1% 43.4% 45.5% 60.8% 52.3% 48.3% 48.9% 51.3% 60.6% 53.3% 54.1% 49.0% 47.6% 62.9% 61.7% 47.1% 59.4% 53.4% 53.0% 63.0% 58.3% 58.0% N (kW) (m3/h) - - 59.9 60.1 - - 61.1 59.3 - 60.1 63.3 62.4 60.6 61.4 62.9 72.4 63.0 59.1 64.6 66.4 67.9 60.1 66.5 60.7 59.1 72.5 70.8 59.4 66.1 59.9 63.2 67.3 62.2 66.3 0.099 0.114 0.169 0.189 0.054 0.068 0.292 0.315 0.106 0.138 0.588 0.690 0.653 0.192 0.219 0.788 0.956 0.942 0.319 0.363 2.018 2.254 0.667 0.767 0.796 1.238 1.372 0.674 2.282 2.422 1.060 3.879 4.250 1.629 855 888 1205 1257 826 875 1788 1813 1262 1344 2652 2794 2705 1689 1792 4472 4536 4343 3148 3338 7176 7133 4779 4844 4854 6832 7023 5027 9457 9313 7052 14310 14377 10429 (mmH2O) 17.36 18.71 21.26 23.15 10.00 11.21 26.99 27.75 13.44 15.26 41.02 45.50 42.67 18.09 20.35 39.34 40.48 38.48 18.20 20.46 62.55 61.81 27.75 28.51 28.63 41.88 44.25 23.21 52.64 51.05 29.27 62.66 63.25 33.28 (RPM) 1462 1467 1430 1442 981 986 1359 1377 959 971 1381 1454 1408 956 963 1411 1432 1419 926 933 1440 1431 959 948 925 923 957 695 956 942 713 968 973 706 Best efficiency point data of the motor-impeller unit 122 CHT CVT Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at a distance of 6 m. Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. Values taken at outlet with 2/3 of the maximum airflow (2/3Qmax). Values taken at the inlet with 2/3 of the maximum airflow (2/3Qmax). 63 125 250 500 1000 2000 4000 8000 Model 63 125 250 500 1000 2000 4000 8000Model 200 39 44 58 60 61 61 56 51 200 35 41 52 55 56 52 50 44 225-4 41 50 60 64 67 64 57 51 225-4 42 51 56 56 60 59 52 46 225-6 30 39 49 53 56 53 46 40 225-6 31 40 45 45 49 48 41 35 250-4 44 53 63 67 70 67 60 54 250-4 46 55 60 60 64 63 56 50 250-6 34 43 53 57 60 57 50 44 250-6 34 43 48 48 52 51 44 38 315-4 49 61 69 71 72 72 64 56 315-4 50 56 62 62 65 68 59 53 315-6 38 50 58 60 61 61 53 45 315-6 39 45 51 51 54 57 48 42 315-8 34 46 54 56 57 57 49 41 315-8 35 41 47 47 50 53 44 38 400-4 56 68 76 78 79 79 71 63 400-4 57 63 69 69 72 75 66 60 400-6 45 57 65 67 68 68 60 52 400-6 46 52 58 58 61 64 55 49 400-8 41 53 61 63 64 64 56 48 400-8 42 48 54 54 57 60 51 45 450-4 60 72 80 82 83 80 73 65 450-4 62 69 74 74 78 77 70 65 450-6 50 62 70 72 73 70 63 55 450-6 50 57 62 62 66 65 58 53 450-8 45 57 65 67 68 65 58 50 450-8 46 53 58 58 62 61 54 49 450-12 35 47 55 57 58 55 48 40 450-12 35 42 47 47 51 50 43 38 500-6 50 64 72 76 75 72 66 60 500-6 54 60 65 66 70 69 62 55 500-8 43 57 65 69 68 65 59 53 500-8 47 53 58 59 63 62 55 48 500-12 35 49 57 61 60 57 51 45 500-12 39 45 50 51 55 54 47 40 560-6 54 68 76 80 79 76 70 64 560-6 57 63 68 69 73 72 65 58 560-8 46 60 68 72 71 68 62 56 560-8 49 55 60 61 65 64 57 50 560-12 39 53 61 65 64 61 55 49 560-12 42 48 53 54 58 57 50 43 630-6 57 71 79 83 72 79 73 67 630-6 61 67 72 73 77 76 69 62 630-8 50 64 72 76 72 72 66 60 630-8 53 59 64 65 69 68 61 54 630-12 42 56 64 68 67 64 58 52 630-12 46 52 57 58 62 61 54 47 To obtain the Lwa sound power spectra in dB(A) at the inlet with the maximum airflow (Qmax), add the values in the following tables to the LpA sound pressure level given on the characteristic curves: Frequency band in Hz 63 125 250 500 1000 2000 4000 8000 2 9 15 15 18 18 11 5 Dimensions in mm Model CHT AøD* øF G H øI CHT-200 552 250 570 450 360 12 CHT-225 570 250 570 450 360 12 CHT-250 632 355 726 560 450 12 CHT-315 682 355 726 560 450 12 CHT-400 755 500 856 710 590 12 CHT-450 770 500 856 710 590 12 CHT-500 846 630 1075 900 750 14 CHT-560 1035 710 1300 1100 900 14 CHT-630 1098 710 1300 1100 900 14 (*) Recommended nominal diameter for duct. CVT Model AA1øD* øF G H øI CVT-200 500 308 250 530 450 360 12 CVT-225 517 308 250 530 450 360 12 CVT-250 580 380 355 705 560 450 12 CVT-315 630 380 355 705 560 450 12 CVT-400 690 475 500 900 710 590 12 CVT-450 705 475 500 900 710 590 12 CVT-500 775 545 630 1100 900 750 14 CVT-560 956 676 710 1295 1100 900 14 CVT-630 1017 676 710 1295 1100 900 14 (*) Recommended nominal diameter for duct. Accessories See accessories section INT C2V AR RM RFT BAC B PA MS BS PT PT/400 S SI 123 CHT CVT Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. The Lp (dB(A)) sound levels given on the curves are free field pressure measurements at 6 metres at the inlet. 4T/4M=1500 r/min 6T/6M=1000 r/min 6T/6M=1000 r/min 124 CHT CVT Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. The Lp (dB(A)) sound levels given on the curves are free field pressure measurements at 6 metres at the inlet. 8T=750 r/min 12T=500 r/min Variation of sound pressure depending on distance Example of use The sound level may vary depending on the roof structure. Fans suitable for use in industrial kitchens. For the correct application of the standard: • Technical Building Code. Basic SI Document for fire safety. Basic HS Document for health and safety. 125 CHRE CHRE Centrifugal roof fans with low noise level Centrifugal roof fans with low noise level and external rotor motor. Fan: • Sheet steel base plate. • Impeller with backward-curved blades made from sheet steel • Bird guard • Sheet steel rain deflector hood with anticorrosive protection Motor: • Class F external rotor motors, IP54 protection • Single-phase 230V.-50Hz., and three-phase 230/400V.-50Hz. • Max. air temperature to transport: -25ºC.+ 50ºC Finish: • Anticorrosive finish in polyester resin, polymerised at 190ºC, after alkaline degreasing and phosphate-free pre-treatment. Order code CHRE722 Centrifugal roof fans with low Impeller size noise level 4T Number of motor poles 4=1400 r/min. 50 Hz 6=900 r/min. 50 Hz T=Three-phase M=Single-phase Technical characteristics Model Speed (r/min) CHRE-722-4T CHRE-722-4M CHRE-825-4T CHRE-825-4M CHRE-1131-4T CHRE-1131-4M CHRE-1131-6T CHRE-1131-6M CHRE-1135-4T CHRE-1135-4M CHRE-1135-6T CHRE-1135-6M CHRE-1240-4T CHRE-1240-4M CHRE-1240-6T CHRE-1240-6M CHRE-1445-4T CHRE-1445-4M CHRE-1445-6T CHRE-1445-6M CHRE-1650-4T CHRE-1650-4M CHRE-1650-6T CHRE-1650-6M 1360 1360 1360 1360 1330 1330 910 910 1280 1280 880 880 1330 1330 860 860 1345 1345 920 920 1380 1380 900 900 Maximum admissible current (A) 230V 400V 0.31 0.18 0.25 0.52 0.30 0.34 0.78 0.45 0.70 0.43 0.25 0.35 0.95 0.55 0.85 0.52 0.30 0.50 1.49 0.86 2.10 0.61 0.35 0.70 2.17 1.25 2.80 1.13 0.65 1.10 3.29 1.90 5.80 1.40 0.81 3.00 Installed power (kW) Maximum airflow (m3/h) 0.02 0.02 0.03 0.03 0.08 0.08 0.03 0.03 0.10 0.10 0.04 0.04 0.30 0.30 0.06 0.06 0.45 0.45 0.15 0.15 0.80 0.80 0.27 0.27 650 650 950 950 2000 2000 1280 1280 2500 2500 1800 1800 4000 4000 2400 2400 5400 5400 3700 3700 7600 7600 5200 5200 (1) The sound level values are measurements of pressure in dB(A) at a distance of 6 m and at 2/3 of the maximum airflow (2/3 Qmax.) 126 Sound pressure1 level at 2/3 of Qmax dB(A) Inlet Outlet 31 31 32 32 39 39 28 28 43 43 31 31 46 46 35 35 53 53 42 42 57 57 45 45 37 37 38 38 45 45 34 34 48 48 38 38 52 52 41 41 59 59 48 48 62 62 52 52 Approx. weight (Kg) 7.6 7.6 9.1 9.1 14.1 14.1 13.6 13.6 19.1 19.1 18.1 18.1 24.8 26.3 22.3 22.8 36.0 38.0 34.5 36.0 40.5 48.5 38.0 40.0 CHRE Erp. BEP (best efficiency point) characteristics MC EC VSD SR Model CHRE-722-4T CHRE-722-4M CHRE-825-4T CHRE-825-4M CHRE-1131-4T CHRE-1131-4M CHRE-1131-6T CHRE-1131-6M CHRE-1135-4T CHRE-1135-4M CHRE-1135-6T CHRE-1135-6M CHRE-1240-4T CHRE-1240-4M CHRE-1240-6T CHRE-1240-6M CHRE-1445-4T CHRE-1445-4M CHRE-1445-6T CHRE-1650-4T CHRE-1650-4M CHRE-1650-6T CHRE-1650-6M MC - - - - C C - - C C - - C C - - C C C C C C C ηe[%] Efficiency N Degree of efficiency [kW] Electrical power [m3/h] Airflow [mmH2O] Static or total pressure (According to EC) [RPM] Speed Measurement category Efficiency category S Static T Total Variable-speed drive Specific relationship EC VSD SR - - - - S S - - S S - - S S - - S S S S S S S - - - - NO NO - - NO NO - - NO NO - - NO NO NO NO NO NO NO - - - - 1.00 1.00 - - 1.00 1.00 - - 1.00 1.00 - - 1.00 1.00 1.00 1.00 1.00 1.00 1.00 ηe[%] - - - - 39.6% 41.7% - - 43.0% 42.4% - - 46.4% 45.3% - - 50.7% 50.5% 42.8% 51.2% 50.9% 44.9% 44.0% N (kW) (m3/h) (mmH2O) - - - - 58.5 60.8 - - 60.9 60.2 - - 60.4 59.2 - - 63.0 63.1 59.9 60.7 60.2 59.4 58.5 0.053 0.057 0.073 0.078 0.160 0.151 0.074 0.080 0.196 0.200 0.108 0.116 0.461 0.467 0.112 0.120 0.668 0.626 0.237 1.246 1.307 0.414 0.416 345 348 561 567 1072 1083 712 719 1182 1191 909 918 1955 2081 1064 1127 3441 3364 2303 4905 4976 3252 3234 11.55 11.32 14.78 14.49 21.71 21.33 9.40 9.21 26.12 26.04 13.19 12.93 40.11 37.27 14.66 13.64 36.10 34.49 16.16 47.71 49.10 20.97 20.75 (RPM) 1368 1361 1367 1360 1352 1341 920 911 1286 1280 885 880 1347 1332 896 889 1355 1360 932 1380 1387 937 934 Best efficiency point data of the motor-impeller unit Acoustic features Values taken at inlet with 2/3 of the maximum airflow (2/3Qmax). Values taken at outlet with 2/3 of the maximum airflow (2/3Qmax). Model 722 825 1131-4 1131-6 1135-4 1135-6 1240-4 1240-6 1445-4 1445-6 1650-4 1650-6 Model 722 825 1131-4 1131-6 1135-4 1135-6 1240-4 1240-6 1445-4 1445-6 1650-4 1650-6 Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. 631252505001000 2000 4000 8000 29 35 46 49 50 46 44 38 30 36 47 50 51 47 45 39 40 49 54 54 58 57 50 44 29 38 43 43 47 46 39 33 44 53 58 58 62 61 54 48 32 41 46 46 50 49 42 36 48 54 60 60 63 66 57 51 37 43 49 49 52 55 46 40 55 61 67 67 70 73 64 58 44 50 56 56 59 62 53 47 60 67 72 72 76 75 68 63 48 55 60 60 64 63 56 51 631252505001000 2000 4000 8000 33 38 52 54 55 55 50 45 34 39 53 55 56 56 51 46 39 48 58 62 65 62 55 49 28 37 47 51 54 51 44 38 42 51 61 65 68 65 58 52 32 41 51 55 58 55 48 42 47 59 67 69 70 70 62 54 36 48 56 58 59 59 51 43 54 66 74 76 77 77 69 61 43 55 63 65 66 66 58 50 58 70 78 80 81 78 71 63 48 60 68 70 71 68 61 53 To obtain the Lwa sound power spectra in dB(A) at the inlet with the maximum airflow (Qmax), add the values in the following tables to the LpA sound pressure level given on the characteristic curves: Frequency band in Hz 63 125 250 500 1000 2000 4000 8000 2 9 15 15 18 18 11 5 127 CHRE Dimensions in mm Model CHRE-722 CHRE-825 CHRE-1131 CHRE-1135 CHRE-1240 CHRE-1445 CHRE-1650 A B EøF G 194 110 30 440 355 212 110 35 440 400 308 176 40 620 450 325 176 40 620 560 351 176 40 620 560 393 228 40 770 710 426 228 40 770 710 HøI 295 12 320 12 360 12 450 12 450 12 590 12 590 12 Variation of sound pressure depending on distance The sound level may vary depending on the roof structure. Characteristic curves Q = Airflow in m /h, m /s and cfm. inwg. 3 3 Accessories Pe= Static pressure in mmH2O, Pa and See accessories section 4T/4M=1500 r/min INT RM 6T/6M=1000 r/min 128 AR RFT PANELS PA MS PT SI CTD CTD Centrifugal roof fans for houses ventilation Low noise centrifugal roof fans for houses ventilation in accordance with the Spanish Technical Building Code Fan: • Sheet steel base plate. • Impeller with backward-curved blades made from sheet steel • Sheet steel rain deflector hood with anticorrosive protection • Adjustable by variation of voltage • Safety switch on request Motor: • Class F external rotor motors, IP54 protection • Single-phase 230V.-50Hz. • Max. air temperature to transport: -40ºC+ 70ºC B version Finish: • Anticorrosive finish in polyester resin, polymerised at 190ºC, after alkaline degreasing and phosphate-free pre-treatment. C version Order code CTD150 C Centrifugal roof fans for houses ventilation Nominal diameter for duct B: Base version C: Duct version Technical characteristics Model Speed CTD 150 CTD 160 CTD 200 CTD 250 CTD 315 (r/min) 2442 2442 2534 2542 2442 Maximum admissible current (A) 230V 0.28 0.28 0.42 0.68 0.90 Installed power (W) 65 65 97 155 208 Maximum airflow (m3/h) 409 409 711 926 1024 Sound pressure1 level at 2/3 of Qmax dB(A) Inlet Outlet 43 37 43 37 46 39 46 41 48 42 Approx. weight (Kg) 4.4 4.4 6.8 7.6 8 (1) The sound level values are measurements of pressure in dB(A) at a distance of 6 m and at 2/3 of the maximum airflow (2/3 Qmax.) Acoustic features The specified values are determined according to free field measurements of pressure and sound levels in dB(A) at a distance of 6 m. Values taken at the inlet with 2/3 of the maximum airflow (2/3Qmax). Values taken at outlet with 2/3 of the maximum airflow (2/3Qmax). Model CTD 150 CTD 160 CTD 200 CTD 250 CTD 315 Model CTD 150 CTD 160 CTD 200 CTD 250 CTD 315 Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. 631252505001000 2000 4000 8000 38 44 54 59 60 61 57 41 38 44 54 59 60 61 57 41 39 50 57 63 64 62 58 54 40 52 56 63 64 62 56 51 44 57 59 64 65 63 62 57 631252505001000 2000 4000 8000 28 37 51 54 58 53 47 32 28 37 51 54 58 53 47 32 31 44 53 57 58 54 50 40 32 44 53 58 61 59 52 43 34 50 55 58 61 59 52 45 129 CTD Dimensions in mm Model CTD-150/B CTD-160/B CTD-200/B CTD-250/B CTD-315/B CTD-150/C CTD-160/C CTD-200/C CTD-250/C CTD-315/C øF AA1 G øDød1 C 344 207.3 107 305 177 6.1 96.5 344 207.3 107 305 177 6.1 96.5 450 214.35 109 405 230 7.1 138 450 245.55 109 405 230 7.1 138 450 245.55 109 405 230 7.1 138 344 207.3 107 305 177 6.1 96.5 344 207.3 107 305 177 6.1 96.5 450 214.35 109 405 230 7.1 138 450 245.55 109 405 230 7.1 138 450 245.55 109 405 230 7.1 138 Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. On request INT Safety switch 130 D 123.5 123.5 168 168 168 123.5 123.5 168 168 168 H 245 245 330 330 330 245 245 330 330 330 øO 147 157 197 247 312 CA-ROOF CA-ROOF Centrifugal roof fans for ventilation of chimneys in houses In-line centrifugal extractor, with built-in cap to carry out the extraction or impulsion of the air in individual dwellings or community housing. • Designed for continuous working, in any position • Possibility of supply with base or directly to pipe, according to the model Construction: • Galvanised sheet base plate • Impeller with backward-curved blades • Galvanised sheet rain deflector hood • Treated with rust-inhibitor paint B version Motor: • Motor with Long Life ball bearings, IPX4 protection • Single-phase 230V.50 Hz. • Working temperature: -20ºC +50ºC • Automatically reset thermal protector C version Order code CA-ROOF125 Centrifugal roof fans Nominal diameter for duct C B: Base version C: Duct version Technical characteristics Model Speed (r/min) Max. admissible current (A) 220-240V Power (W) Maximum airflow (m3/h) Irradiated* Sound Level dB(A) Weight (Kg) CA/ROOF 125 2300 0.34 75 350 54 CA/ROOF 150 2370 0.34 80 450 56.5 5 7 CA/ROOF 160 2650 0.68 150 750 64 8.8 CA/ROOF 200 2700 0.69 160 850 63 8 CA/ROOF 250 2430 0.80 180 1180 61.5 9.9 CA/ROOF 315 2480 1.10 250 1600 64.5 11 *Irradiated sound pressure level are free field measurements at 3 metres Dimensions in mm Model CA/ROOF 125 A B C 334 280 20 D E F Ø G Ø H 2 193 290 122 300 CA/ROOF 150 424 370 20 17 198 340 147 400 CA/ROOF 160 424 370 20 22 214 361 157 400 CA/ROOF 200 424 370 20 17 203 345 197 534 CA/ROOF 250 489 435 20 27 193 376 247 534 CA/ROOF 315 489 435 20 21 226 403 312 534 Accessories See accessories section INT RM SI 131 CA-ROOF Characteristic curves 150 200 30 1,2 25 1,0 200 20 0,8 150 15 0,6 100 10 0,4 50 5 0,2 0 0 100 0,06 0,08 100 200 300 2,5 60 300 30 100 10 0 0 1,5 0,5 0 200 400 0,05 0,0 800 Q (m3/h) 600 0,10 0,15 0 Q (cfm) 200 400 600 2,0 50 40 1,5 30 0,4 50 5 0,2 0 0 10 0 0 100 500 0,02 200 0,04 300 0,06 0,08 0,0 500 Q (m3/h) 400 0,10 0 Q (m /s) 3 0,12 200 60 Q (cfm) 100 200 300 400 500 2,0 50 40 1,5 30 200 20 100 10 0 0 0,5 0 200 0,00 0,05 400 0,10 600 0,15 0 0,0 1000 Q (m3/h) 800 0,20 Q (m /s) 3 0,25 315 80 Q (cfm) 200 400 600 800 1000 3,0 700 70 600 60 500 50 400 40 300 30 200 20 100 10 0 0 2,5 2,0 1,5 1,0 0,5 100 0 0,00 20 0 0,00 132 10 3 1,0 200 100 Q (m /s) 0,20 250 Pe Pe (Pa) 300 0,6 Pe (in wg) 400 15 300 Pe (in wg) 500 150 1,0 0,00 60 0,8 Pe (Pa) 20 20 400 1,0 200 250 200 Pe 40 200 2,0 50 400 150 1,0 3 400 100 25 Q (m /s) 0,10 Q (cfm) 0 250 Q (cfm) 50 Pe (in wg) 500 0,04 Pe (in wg) 70 600 0,02 0,0 400 Q (m3/h) 300 160 Pe Pe (Pa) 0,00 200 30 Pe (Pa) 0 150 0 Pe 100 Pe Pe (Pa) Q (cfm) 50 Pe (in wg) 250 0 Pe (in wg) 35 300 Pe= Static pressure in mmH2O, Pa and inwg. 125 Pe Pe (Pa) Q = Airflow in m3/h, m3/s and cfm. 200 0,05 400 0,10 600 0,15 800 0,20 1000 0,25 0,30 0,0 3 1200 Q (m /h) Q (m /s) 3 0,5 0 0,0 300 0,1 600 900 0,2 1200 0,3 1500 0,4 0,0 3 1800 Q (m /h) 0,5 Q (m /s) 3 TIRACAMINO TIRACAMINO free Fans to extract smoke in chimneys and barbecues • Designed especially to extract smoke up to 200ºC in chimneys and barbecues • Equipped with an electronic regulator so as to regulate the speed and the flow of the extractor according to the real need for smoke extraction • Designed for continuous operation at 200ºC Construction: • Manufactured in sheet steel with polyester resin to stand up to atmospheric agents • Bird guard • Supplied voltage 230V 50 Hz Motor: • BASIC: works with separate switch or regulator Technical characteristics Model TIRACAMINO (r/min) Maximum admissible current (A) 230V Absorbed power (W) 1400 0,50 120 Speed Maximum airflow (m3/h) 750 Sound pressure level(*) dB(A) 52 Approx. weight (Kg) 14,3 (*) The sound level values are measurements of pressure in dB(A) at a distance of 3 m with maximum airflow Dimensions in mm Characteristic curves Q = Airflow in m3/h, m3/s and cfm. Pe= Static pressure in mmH2O, Pa and inwg. 133 HTSOLAR HTSOLAR free Mixed (wind + solar) roof fans without electrical installation and without electricity consumption + Roof fan with operation by means of photovoltaic panel with variable angle of incidence or by means of wind energy. Totally self-sufficient WITHOUT electrical installation and WITHOUT electricity consumption Fan: • Made from galvanised sheet • Aluminium sheet impeller • Activation of the fan by means of a built-in thermostat: ON (26.5ºC)/OFF (18ºC) HTSOLAR-45 Solar-powered roof fans without electrical installation and without electricity consumption Roof fan with operation by means of photovoltaic panel with variable angle of incidence. Fan: • Sheet steel base with anti-corrosive treatment • Impellers made from polyamide • Sheet steel hood with anti-corrosive treatment • Activation of the fan by means of a built-in thermostat: ON (26.5ºC)/OFF (18ºC) HTSOLAR-45-S HTSOLAR-45-D Order code HTSOLAR Roof fans without electrical installation and without electricity consumption 45 D Impeller diameter (cm) D: two-fan version S: one-fan version Technical characteristics Model HTSOLAR-31 HTSOLAR-45 HTSOLAR-45-S HTSOLAR-45-D 134 (r/min) Maximum admissible current (A) 2450 1350 1350 1350 1.10 3.50 3.50 3.50 Speed Installed power (kW) 0.015 0.10 0.10 2 x 0.10 Maximum airflow (m3/h) 1920 3010 2800 5600 Sound pressure level dB(A) Inlet Outlet 45 48 48 51 44 50 50 53 Approx. weight (Kg) 6 55 34 65 HTSOLAR Dimensions in mm HTSOLAR-31 HTSOLAR-45 HTSOLAR-45-S HTSOLAR-45-D Characteristic Curves HTSOLAR-31 HTSOLAR-45 HTSOLAR-45-S HTSOLAR-45-D 135 RCH RCH-400x800VM RCH Fan and chimney top for hybrid extraction in community housing • Designed especially for the extraction of air in houses or community housing, through chimneys or shunts. It makes it possible to maintain an attractive and uniform design throughout the house • The Venturi version, only for natural extraction, without an extractor • The lightness of the aluminium means that installation on the roof is rapid and simple Construction: • Manufactured in black pre-lacquered aluminium which is not altered by atmospheric agents. • Perfectly designed slats so as to obtain a high-performance Venturi effect • Supplied voltage 230V 50 Hz Versions: • BASIC: It works with a switch or with a SI-VENT wind monitor • V ENTURI: Natural operation without an extractor using the Venturi effect • TEMPERATURA: Designed for the extraction of air in homes and barbecues with a maximum temperature of 150ºC On request: • Measurements to fit any chimney SI-VENT Accessories SYSTEM OF HYBRID VENTILATION (H.V) This system is based on the extraction of air in a natural manner when the wind conditions outside are favourable and when they are unfavourable the extractor with an electric motor comes into operation so as to guarantee the minimum necessary extraction. The start up of the electrical extractor is carried out by means of wind sensors, which are especially designed for this application WIND CONTROLLER SI-VENT, Wind sensor The SI-VENT electronic wind controller is a highly robust and reliable device, made up of a sensor, a controller and the power supply. The sensor is capable of measuring winds of up to 100 k.p.h. and the controller starts up the electrical extractor when the wind speed is below the programmed minimum wind value for five minutes. 136 RCH RCH-400x800VM RCH-400x800VM free Fan and chimney top for hybrid extraction in community housing An assembly specially designed for controlled mechanical extraction through chimneys or condominium shunt chimneys. The system makes it possible to maintain a constant pressure in the installation, with the speed of the extractor self-regulated, obtaining the flow necessary at each moment according to the different needs of the installation, achieving a significant energy saving • It makes it possible to maintain an attractive and uniform design throughout the house. • The lightness of the aluminium means that installation on the roof is rapid and simple • On demand, measures adapted to any chimney Construction: • Manufactured in black pre-lacquered aluminium which is not altered by atmospheric agents • Perfectly designed slats so as to obtain a high-performance Venturi effect • Impeller unit with backward-curved blades with external rotor motor • Adjustable differential pressure transmitter from 0 ….250 Pa, including screen for digital display and connection accessories • Speed regulator by means of a frequency converter RFM-0,5 Motor: • Motor with Long Life ball bearings, IP54 protection • Converter supply, single-phase 230V. 50 Hz., converter output voltage to motor, three-phase 230V. 50Hz • Working temperature: -20ºC +50ºC Technical characteristics Model Speed Max. admissible current (A) 220-240V (r/min) Installed power Maximum airflow (kW) (m3/h) Sound pressure (1) level at 2/3 of Qmax dB(A) Inlet Outlet Weight approx. (Kg) RCH-400x400B 1360 0.34 0.03 950 32 35 9 RCH-400x400T 1380 0.65 0.25 1450 37 40 25 RCH-400x600B 910 0.35 0.03 1280 28 31 14 RCH-400x800B 880 0.50 0.04 1800 31 35 18 1280 0.95 0.10 2500 43 48 19 RCH-400x800VM (1) The sound level values are measurements of pressure in dB(A) at a distance of 6 m and at 2/3 of the maximum airflow (2/3 Qmax.) Dimensions in mm A A C C Model RCH-400x400B RCH-400x400T RCH-400x600B A B C Useful area 420 RCH-400x400V 400 400 600 0.134 m2 600 RCH-400x600V 400 600 600 0.191 m2 600 420 RCH-400x800V 400 800 600 0.248 m2 A BC 400 400 400 400 400 RCH-400x800B 400 800 420 RCH-400x800VM 400 800 420 Model 137 RCH RCH-400x800VM Characteristic curves RCH 0 200 400 600 800 cfm 1000 1 25 Pa 250 Pe= Static pressure in mmH2O, Pa and inwg. in wg Q = Airflow in m3/h, m3/s and cfm. 200 150 0.8 20 400x400T 400x400B 15 0.6 400x600B 100 10 50 5 0.4 0.2 400x800B 0 0 0 0 400 0.1 800 0.2 1200 0.4 0.6 RCH-400x800VM Examples of operation B and T version 138 1600 V version 2000 0.8 0 m3/h m3/s ACCESSORIES ACCESSORIES RM INT C2V 140 140 PL ELECTRICAL PANELS P 142 RI Protection guard for outlet of axial fans. PS BAC Inlet hood with guard PT PT/H 144 Three-phase asynchronous motors 148 BSS 145 PA High base plate and high base plate with silencer Support stands for longcased fans. 145 Support frame to facilitate mounting on-site. 146 146 146 Backdraught shutters for roof fans 147 Adaptation plate to mount accessories on roof fans. 146 S REG OP Automatic-closing shutters to work in vertical and horizontal position certified for 400ºC/2h 146 MOTORS Coupling flange for centrifugal fans. 144 BS MS PT/H - 400 Obturadores de cierre automático para trabajo vertical o horizontal B Coupling flange for axial fans. Double, elastic coupling flange for axial fans 145 144 143 BTUB 144 144 Protection guard for aspiration of axial fans. Backdraught louvres certified for 400ºC/2h 143 Protection guard for inlet or outlet of long-cased axial fans. 141 R Aluminium backdraught louvres PV Frequency converters for 400 V three-phase motors. 140 P-400 143 RT Smooth starters for three-phase motors. 140 Backdraught shutters Electrical panels RFT RFM Switch for twospeed motors Electronic speed controllers On/Off safety switches in accordance with Standard UNEEN 60204-1. AR Record of regulation manual 147 Silencers to fit to inlet or outlet 147 INTELLIGENT SENSORS 149 139 ACCESSORIES INT Stop-start safety switches in accordance with Standard UNE-EN 60204-1. Model Features: • Switch to be placed beside the fan, so that mains current can be cut without handling the fan • IP65 protection • For three-phase or two-speed fans, use 6-pole switch • For single-phase fans, use a 3-pole switch RM 20 20 25 32 40 63 80 100 5.5 5.5 7.5 11 15 22 30 37 Model Cables input (mm) 19 23 29 29 37.5 37.5 37.5 37.5 Current (A) INT-CA 10/6CA INT-KG 10/6CA INT-KG 20/6CA INT-KG 32/6CA INT-KG 41/6CA INT-KG 64/6CA INT-KG 80/6CA INT-KG 100/6CA 20 20 25 32 40 63 80 100 (kW) Cables input (mm) 5.5 5.5 7.5 11 15 22 30 37 19 23 29 29 37.5 37.5 37.5 37.5 Electronic speed controllers • Minimum speed adjustment • With EMC filters in accordance with standard EN-55014 Protection Maximum current (A) 230 V-50/60 Hz IP-44 0,5 230 V-50/60 Hz IP-44 1 230 V-50/60 Hz IP-44 2 230 V-50/60 Hz IP-54 3 230 V-50/60 Hz IP-54 5 230 V-50/60 Hz IP-54 10 Model Input voltage RM-00 RM-01 RM-02 RM-1 RM-2 RM-3 Model RM-00 RM-01 RM-02 RM-1 RM-2 RM-3 B A 81 81 81 81 81 81 80 145 96 164 96 164 C 66 66 66 80 85 85 Switch for two-speed motors Features: • 1-0-2 three-position switch to operate two-speed motors with Dahlander connection • IP67 protection AR (kW) INT-CA 10/3CA INT-KG 10/3CA INT-KG 20/3CA INT-KG 32/3CA INT-KG 41/3CA INT-KG 64/3CA INT-KG 80/3CA INT-KG 100/3CA Features: • Electronic speed controllers especially designed for fans with single-phase motors, in accordance with standard EN-60335 • Models RM-1, RM-2 and RM-3, IP-54 protection. Models RM-00, RM-01 and RM02, IP-44 protection • In accordance with Electromagnetic Compatibility Directives 92/31/EEC and 93/68/EEC and in accordance with Low Voltage Directive 73/23/EEC • On/off switch. C2V Intensity (A) Model Intensity (A) (kW) 20 5,5 C2V-CG10 A441 Cables input (mm) 20 Soft starters for three-phase motors. Features: • Especially designed to reduce the current peak caused during start-up of fans with three-phase motors. • Supplied voltage 400V + - 10% 50/60Hz • Mounted in box for DIN-35 rail • Possibility of adjusting the starting torque, acceleration time and deceleration time. Model AR-2AR-4AR-7.5AR-10AR-15 AR-20 AR-30 Supplied voltage400 V ±10% 50/60 Hz Motor power in kW at 400 V Minimum motor power 1.5 3 5.5 7.5 11 15 22 4 0% of the motor’s nominal power20% of the motor’s nominal power External fuses (quick-action) in (A) 16 25 35 25 35/40 50 63 Nominal current in (A) 3.5 6.5 12 17 25 32 45 Adjustment range of start-up torque Adjustment range of start-up time From 0 to 80% From 0.5 to 12 sFrom 0.5 to 10 s Braking torque Level set at 70% Adjustment range of deceleration timeFrom 0.5 to 12 sFrom 0.5 to 10 s Setup time 200 ms Working temperature 0ºC….45ºC Storage temperature -25ºC….75ºC Protection level IP20 Environmental conditionsOverpressure category III. Pollution level 2 Power reduced with max. temperature1% for every 1ºC increase in the maximum temperature Maximum height for mounting Up to 1000 m Power reduced with max. height0.5% for every 100 m over 1000 m. Humidity93% maximum without condensation Maximum cycles per hour (3 x I nom. 10 sec) 140 60/h 40/h Weight in kg. 90/h 60/h 0.4 30/h 1.0 30/h 20/h Measurements Width (W) mm Height (H) mm 45 45 52.5 73 173 Depth (D) mm 178 122 152 Assembly Fixing A x B 158 On DIN guide rail ACCESSORIES RFT RFM Frequency converter for 400V three-phase motors. Features: • The RFT converter series are suitable to vary the speed, via voltage and frequency, of axial and centrifugal fans with 400V three-phase motors. Converter supply: three-phase 400V. 50/60 Hz. • In accordance with Electromagnetic Compatibility Directives 92/31/EEC and 93/68/EEC and in accordance with Low Voltage Directive 73/23/EEC Model Features: • The RFT converter series are suitable to vary the speed, via voltage and frequency, of axial and centrifugal fans with 230V three-phase motors. Converter supply: single-phase 230V. 50/60 Hz. • In accordance with Electromagnetic Compatibility Directives 92/31/EEC and 93/68/EEC and in accordance with Low Voltage Directive 73/23/EEC RFT-0.5 RFT-1 RFT-2 RFT-3 RFT-5.5RFT-7.5RFT-10 RFT-15RFT-20 RFT-25 Motor RFT-30 (CV) 0.5 1 2 3 5.5 7.5 10 15 20 25 30 (kW) 0.37 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 Intensity (A) 1.25 2.5 4 6 9 12 16 24 30 39 45 kVA 0.95 1.9 3 4.5 6.9 9.1 12.2 19.1 23.9 31.1 35.9 Frequency (Hz) 0….400 Hz 0...120 Hz InputThree-phase Voltage (V)3 x 380…480 V (-15% +10%) Frequency (Hz)50 – 60 Hz (± 5%) OutputThree-phase Voltage (V)3 x 380…480 V Braking torque 20% (with external resistance: 100%. 150%) Braking unit Size Width (W1) mm Optional 70 100 140 140 180 180 200 250 250 304 Height (H1) mm 128 128 128 128 128 220 220 284 385 385 460 Depth (D1) mm 130 130 130 155 155 170 170 182 201 201 234 0.76 0.77 1.12 1.84 1.89 3.66 3.66 6 12.5 13 20 Weight (Kg) Method of refrigeration Model Motor Intensity (A) kVA Incorporated in the equipment 70 Forced air RFM-0.5 RFM-1RFM-2RFM-3 Model (CV) 0.5 1 2 3 (kW) 0.37 0.75 1.5 2.2 Frequency (Hz) 2.5 5 8 12 RFI Filter 0.95 1.9 3 4.5 Size Width InputSingle-phase Voltage (V)2 x 200 ÷ 230 V (±10%) Frequency (Hz)50 – 60 Hz (± 5%) Output Three-phase RFM-0,5 RFM-1RFM-2RFM-3 Voltage (V)3 x 200 ÷ 230 V 0-200Hz (W1) mm 0-400Hz 0-400Hz Built in 0-400Hz 68 79 156 156 Height (H1) mm 128 143 143 143 Depth (D1) mm 115 143 143 143 0,95 0,97 1,94 2,00 Radiador Forced air Forced air Forced air Weight (Kg) Method of refrigeration 1. In general, all SODECA fans with a threephase motor under normal operating conditions are suitable for working supplied with a static frequency converter (in accordance with IEC 60034-17). Nevertheless, some motors require special measures. The maximum operating frequency or speed must never exceed that for which the fan has been designed. In applications with quadratic torques such as fans and pumps, when the speed varies the absorbed power is directly proportional to the cube of the rotating speed: Pa2 = Pa1 (n2 / n1)3 2. The insulation of motors coupled to fans is sufficient to work without restrictions with a frequency converter up to voltages of < 500 V. The use of sinusoidal filters at the converter output will help the motor to operate properly, reducing breakdowns and increasing the fan’s service life. It is recommended that, for motors of sizes > 225, they be ordered with special windings to work with a frequency converter. 3. The length of the wires running from the converter to the fan have a particular influence on voltage characteristics at the motor terminals. The definition of "long wires" will depend on the nominal value and the converter type. The manufacturer’s technical documentation must be consulted. 4. EEx-d flame-resistant motors must be ordered for operation using a frequency converter. The motor manufacturer will request information about the application via a questionnaire in order to establish the working parameters. These motors must also be fitted with PTC probes. 5. EEx-e increased safety motors cannot be operated with a frequency converter (a joint motor-converter certification would be required for this). 141 ACCESSORIES KME - 10K External control kit for On/Off and velocity control for RFM and RFT frequency converters Features: • On/Off by button • Display by means of LED of the position of On or Off • Memory of the latest position for speed regulation GMP • Possibility of installation on the surface or built-in Electrical starter panel and protection of fans with three-phase motor, with On/Off buttons Features: • On/Off by button • Incorporates fully-cabled contactor and adjustable thermal relay for protection of the motor • The Off button is used to reset the thermal relay, in case it should go off due to overload • For assembly on the surface, IP-55 protection Model For fan with three-phase motor 230V Intensity regulation (A) GMP-0.2-0.33/230 GMP-02-0.75/230 GMP-02-1/230 GMP-02-1.5/230 GMP-02-2/230 GMP-04-3/230 GMP-04-4/230 GMP-04-5.5/230 GMP-04-7.5/230 GMP-04-10/230 GMP-06-12.5/230 GMP-06-15/230 GMM 1.2-1.8 1.8-2.8 2.8-4 4-6.3 5.6-8 7-10 8-12.5 11-17 15-23 22-32 25-40 25-40 Power motor 3x230V (kW) 0.25 0.37 / 0.55 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 9.20 11.00 Model For fan with three-phase motor 400V GMP-0.2-0.33/400 GMP-02-0.5/400 GMP-02-0.75/400 GMP-02-1.5/400 GMP-02-2/400 GMP-02-3/400 GMP-02-4/400 GMP-04-5.5/400 GMP-04-7.5/400 GMP-04-10/400 GMP-06-12.5/400 GMP-06-15/400 GMP-06-20/400 GMP-06-25/400 Electrical starter panel and protection from overload and short-circuits of fans with threephase motor, with rotary controls Features: • On/Off by means of a rotary control with the possibility of blocking with three locks • Incorporates adjustable thermal relay for protection from overload and short-circuit • For assembly on the surface, IP-55 protection AET For fan with three-phase motor 230V/400V. Power supply 3x230V AET-01-3/230 AET-01-4/230 AET-01-5.5/230 AET-01-7.5/230 AET-01-10/230 AET-01-15/230 AET-01-20/230 AET-01-25/230 AET-02-30/230 AET-02-40/230 AET-02-50/230 142 Model Power motor 3x400V (kW) 0.25 0.37 0.55 1.10 1.50 2.20 3.00 4.00 5.50 7.50 9.20 11.00 15.00 18.50 For fan with three-phase motor 400V GMM-01-1/400 GMM-01-2/400 GMM-01-3/400 GMM-01-5.5/400 GMM-01-7.5/400 GMM-01-10/400 GMM-01-15/400 GMM-01-20/400 Intensity regulation (A) 1.6-2.5 2.5-4 4-6.3 6.3-10 10-16 16-20 20-25 25-32 Power motor 3x400V (kW) 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 11.00 15.00 Electrical starter panel, star / triangle and protection of fans with three-phase motor, with On/Off buttons Features: • On/Off by button • Display of condition by means of luminous pilot lights • Incorporates adjustable thermal relay for protection of the motor Model Intensity of regulation (A) 0.56-0.8 0.8-1.2 1.2-1.8 1.8-2.8 2.8-4 4-3 5.6-8 7-10 8-12.5 11-17 15-23 15-23 22-32 25-40 Current regulation of thermal relay (A) 4-6.3 5-8 7-10 12-18 12-18 18-26 24-36 28-40 34-50 45-65 63-85 Power motor 3x230/400V (kW) 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5 22.0 30.0 37.0 • Fully cabled • Metal plate for assembly on the surface, IP-65 protection For fan with three-phase motor 400V/690V. Power 3x400V+N Model AET-01-5.5/230 AET-01-7.5/230 AET-01-10/230 AET-01-15/230 AET-01-20/230 AET-02-30/230 AET-02-40/230 AET-02-50/230 AET-02-60/230 AET-02-75/230 Current regulation of thermal relay (A) 4-6.3 5-8 7-10 12-18 12-18 18-26 28-40 34-50 45-65 45-65 Power motor 3x400/690V (kW) 4.0 5.5 7.5 11.0 15.0 18.5 22.0 30.0 37.0 45.0 55.0 ACCESSORIES Electrical starter panel and protection of fans with three-phase motor, with two DAHLANDER speeds For fan with three-phase 400V Dahlander motor. Power 3x400V+N Features: • Switch for selecting speed (1-0-2), Low-Off-High. • Display of condition by means of luminous pilot lights • Incorporates adjustable thermal relay for protection of the motor • Fully cabled • Metal plate for assembly on the surface, IP-65 protection PL Current regulation of thermal relay High speed (A) Low speed (A) Model AD-01-2.5-1/400 AD-01-4-1.6/400 AD-01-4-2.5/400 AD-01-6-2.5/400 AD-01-9-2.5/400 AD-01-9-4/400 AD-02-13-4/400 AD-02-18-6/400 AD-02-18-9/400 AD-02-26-9/400 AD-02-36-9/400 AD-02-36-13/400 AD-02-40-18/400 ModelMeasurements A C ØD E F P-25 290 51 6 187 51.5 P-35 400 81 6 266 67 P-45 500 51 6 347 76.5 P-56 600 51 6 447 76.5 P-63 715 72 6 535 90 P-71 780 72 6 605 87.5 P-80 875 72 6 675 100 P-90 970 72 6 755107.5 P-100 1070 72 6 850 110 Aluminium backdraught louvres Features: • The backdraught louvre is adapted directly to the wall where the fan is mounted. • Opening through excess pressure due to airflow • Closed when the fan is on standby • Aluminium sheet construction • Maximum recommended speed 18m/sec for models 80, 90 and 100 D1 A Features: • Supplied mounted in the box with appropriate adapter • Standardisation in accordance with standard EN-12101-3- 2002, certificate no.: 0370-CPD-0312 • Frame made from sheet steel and slats from aluminium sheet. • Can be used for other 400ºC/2h applications P F Backdraught louvres, certified for 400ºC/2h. E D F E P-400 0.63-1 1-1.6 1.6-2.5 1.6-2.5 1.6-2.5 2.5-4 2.5-4 4-6 6-9 6-9 6-9 9-13 12-18 ModelMeasurements A CØD E F PL-20 240 28 5,2 193 167 PL-25 294 26 5 232 232 PL-31 347 26 5 276 276 PL-35 397 26 5 310 310 PL-40 459 26 5 364 364 PL-45 501 26 5 395 395 PL-50 549 31 5 445 445 PL-56 605 28 5 522 522 PL-63 696 31 5 626 626 PL-71 760 40 5 692 692 PL-80 840 40 5 772 772 PL-90 940 40 5 872 87 PL-100 1040 40 5 972 972 Plastic backdraught louvres. Features: • The backdraught louvre is adapted directly to the wall where the fan is mounted. • Opening through excess pressure due to airflow • Closed when the fan is on standby • Made from plastic • Maximum recommended speed 12m/sec for models 80, 90 and 100 P 1.6-2.5 2.5-4 2.5-4 4-6 6-9 6-9 9-13 12-18 12-18 18-26 24-36 24-36 28-40 A Model P-400-56 P-400-63 P-400-80 P-400-100 Q AD C A C ØD E F P QD1 645 51 6 492 76.5 595 595 10 760 72 6 580 90 720 720 10 915 72 6 715 100 880 880 10 1115 72 6 895 100 1080 1080 10 143 ACCESSORIES R Protection guard for aspiration of axial fans. Model HCHCH Model HCHCH R-35/B R-40 R-45 R-56 R-56 - 1,5 R-63 - 0,5 R-63 - 1,5 R-63 - 4 R-71 R-71/C R-71-3 R-80 R-80/C R-80 - 5,5 R-90 80 - R-90/C R-90 - 7,5 R-100 R-100/C R-100-7,5/C R-100 - 10 90 90-4T-7.5, 90-4T-10, 90-6T-4, 90-8T-3 100-6T-3, 100-8T-1.5, 100-8T-2 100 100 4T/H 100-4T-7.5, 100-4T-10, 100-6T-4, 100-6T-5.5, 100-8T-1.5, 100-8T-2 100-4T-15, 100-4T-20 - 71 - 35 40 45 56-4T/M-0.75, 56-4T-1, 56-6T/M-0.33, 56-6T-0.5, 56-6T-0.75 56-4T-1.5, 56-4T-2 63-4T-1, 63-6T/M-0.5, 63-6T-0.75 63-4T-1.5, 63-4T-2, 63-6T-1 63-4T-3, 63-4T-4 71-4T-1.5, 71-4T-2, 71-6T/M-0.75, 71-6T-1, 71-6T-1.5 71-4T-3, 71-4T-4 80-6T-1, 80-6T-1.5, 80-8T-0.5, 80-8T-0.75 RI R-100 - 20 Protection guard for outlet of axial fans. Model HEP RI-20 RI-25/E RI-25 RI-31/E RI-31 RI-35/E RI-35/B RI-35/C RI-40 RT HCD HC HRE PV 144 Model RI-45 RI-50 RI-56 RI-63 RI-71 RI-80 RI-90 RI-100 HEP HCD 45 50 56 63 - - - - HC -45 -50 -56 -63 -71 -80 -90 -100 HRE HCH - - - - - - - - 45 - 56 63 71 80 90 100 Protection guard for inlet or outlet of long-cased axial fans. Model HEPT HCT HGTHPX RT-45 45 45 -45 RT-50 50 50 -50 RT-56 56 56 -56 RT-63 63 63 -63 RT-71 - 71 -71 Model HEPT HCT HGTHPX RT-80 - 80 -80 RT-90 - 90 -90 RT-100 - 100 -100 RT-125 - -125 RT-125/CC - -125 - Inlet hood for use with the HEPT, HCT, HGT and HTP series Model øA øB øDød E M H Model PV-31 398 355 32010 1.5 8x45º165 PV-80 PV-35 438 395 35910 1.5 8x45º165 PV-90 PV-40 484 450 40112 1.5 8x45º165 PV-100 PV-45 534 500 45012 1.5 8x45º165 PV-125 PV-50 584 560 50412 1.5 12x30º165 PV-140 PV-56 664 620 56512 1.5 12x30º165 PV-160 PV-63 734 690 63412 1.5 12x30º165 PV-180 PV-71 812 770 71112 2 16x22.5º250 PV-200 BTUB - 25 -31 31 - 35 35 40 40 45 45 øA øB øDød 904 860 79712 1004 970 89414 11051070 1003 14 13701320 1240 14 15331470 1413 15 17051680 1585 19 19081830 1788 19 21132080 1993 19 E M H 2 16x22.5º250 2 16x22.5º250 2 16x22.5º 250 2 20x18º 250 3 20x18º 250 3 24x15º 315 3 24x15º 315 3 24x15º 315 Coupling flange for axial fans. HEPT HCT HGTHPX HT* BTUB-250 BTUB-280 BTUB-315 BTUB-355 BTUB-400 BTUB-450 HCH -20 - - - - --25 - 25 2525 - - - --31 - 31 3031 - - - --35 - - -- - 35 35 3535 - - 40 4040 - 40 Model HEPT HCT HGTHPX RT-25 -25 -RT-31/B -31 -RT-31 31 - -RT-35 35 35 -35 RT-40 4040 -- Model 80-4T-3, 80-4T-4, 80-4T-5.5, 80-6T-2, 80-6T-3, 80-8T-1 90-4T-4, 90-4T-5.5, 90-6T-2, 90-6T-3, 90-8T-1, 90-8T-1.5, 90-8T-2 - -25 --- -31 - -35 - -40 -4545 Model HEPT HCT HGTHPX HT* BTUB-500 BTUB-560 BTUB-630 BTUB-710 BTUB-800 BTUB-900 50 56 63 - - - 50 56 63 71 80 90 -5050 -5656 -6363 -7171 -8080 -9090 Model HEPT HCT HGTHPX HT* BTUB-1000 BTUB-1250 BTUB-1400 BTUB-1600 - 100 -100100 - - 125-- - 140-- - 160-- * For installation, the PA accessory must be used ACCESSORIES B Coupling flange for centrifugal fans. Features: • Adapted to inlet and outlet. • Aids installation on duct AC F B-52-E B-63 B-80 B-80-E B-100 B-100-E B-112 B-125 B-140 B-150 B-160 B-160/1 B-180 B-200 100 110 150 150 150 170 160 180 190 210 220 220 240 260 52 63 80 80 100 100 112 125 140 150 160 160 180 200 67 60 60 60 60 60 60 60 60 60 60 60 60 60 AC F B-224 B-250/1 B-250/2 B-250/3 B-250/4 B-250/5 B-280/1 B-280/2 B-280/3 B-315/1 B-315/2 B-315/3 B-315/4 B-355/1 280 310 310 310 310 310 350 350 350 350 380 380 380 430 224 250 250 250 250 250 280 280 280 315 315 315 315 355 60 80 80 80 80 80 80 80 80 80 80 80 80 80 B-355/2 B-355/3 B-355/4 B-400/1 B-400/2 B-400/3 B-400/4 B-450/1 B-450/2 B-450/3 B-500/1 B-500/2 B-500/3 B-500/4 AC F 430 430 430 480 480 480 480 530 530 530 590 590 590 590 355 355 355 400 400 400 400 450 450 450 500 500 500 500 80 80 80 80 80 80 80 80 80 80 80 80 80 80 AC F B-500/5 590 500 B-560/1 650 560 B-560/2 650 560 B-560/3 650 560 B-630/1 720 630 B-630/2 720 630 B-630/3 720 630 B-630/4 720 630 B-710/1 800 710 B-710/2 800 710 B-710/3 800 710 B-800 890 800 B-900/1 1000 900 B-1000/1 1100 1000 80 80 80 80 80 80 80 80 80 80 80 100 100 100 ModelCHT/CVTCHRE ModelCHT/CVTCHRE ModelCHT/CVTCHRE ModelCHT/CVTCHRE ModelCHT/CVTCHRE B-52-E- B-63- B-80- B-80-E- B-100- B-100-E- B-112- B-125- B-140- B-150- B-160- B-160/1- 722 B-180- 825 B-200- - B-224- - B-250/1- - B-250/2- - B-250/3 200/2251131 B-250/4- - B-250/5- - B-280/1- - B-280/2- - B-280/3- - B-315/1- - B-315/2- - B-315/3- - B-315/4- - B-355/1- - B-355/2- - B-355/3 250/3151135/1240 B-355/4- - B-400/1- - B-400/2- - B-400/3- - B-400/4- - B-450/1- - B-450/2- - B-450/3- - B-500/1- - B-500/2- - B-500/3- - B-500/4 400/4501445/1650 B-560/1- - B-560/2- - B-560/3- - B-630/1- - B-630/2- - B-630/3500 - B-630/4- - B-710/1- - B-710/2 560/630- B-710/3- - B-800- - B-900/1- - B-1000/1- - - - - - - - - - - - - BAC Double, elastic coupling flange for axial fans ØD*ØA* H BAC-250 250 310 340 BAC-355 355 430 340 BAC-400 400 480 340 BAC-450 450 530 340 BAC-500 500 590 340 BAC-560 560 650 340 BAC-630 630 720 340 BAC-710 710 800 340 BAC-800 800 890 340 BAC-900 900 1000 340 BAC-1000 1000 1100 340 BAC-1250 1250 1365 340 Features: • Adapted to inlet and outlet • Aids installation on duct with flange • Prevents transmission of vibrations Model HEPT HCT HGT BAC-160 - - BAC-180 - - BAC-250 - 25 BAC-315/B -31 BAC-315 31- BAC-355 35 35 BAC-400 4040 BAC-450 4545 CHT HT HPX - - - - - - -200/225 25 - - - - -31 - 250/315 - - PS 35 - 40 - 45 CHRE -722 -825 - 1131 - - 351135/1240 - 45 - Model HEPT HCT HGT CHT HT HPX CHRE BAC-500 50 50 - 400/450 50 50 1145/1650 BAC-560 5656 - - 56 56 BAC-630 6363 -500 63 63 BAC-710 - 71 -560/630 71 71 BAC-800 -80 - - 80 80 BAC-900 -90 - - 90 90 BAC-1000 -100 - - 100 100 BAC-1250 --125 - - - - *Nominal diameter for pipe. Support stands for long-cased fans. Features: • When fixed to the flange, it allows the fan to be fixed to flat surfaces. PS-25/31 PS-35/40 PS-45/50 PS-56/63 PS-71 PS-80 PS-90 PS-100 PS-125 A B B1 275 225 - 275 225 - 275 225 - 240 200 - 240 200 - 450 400 200 450 400 200 520 430 215 520 430 215 490 450 225 600 560 280 620 560 280 680 560 280 1000 900 300 C D h HØJ 25 10,5 90 165 10 25 10,5 90 191,5 10 25 10,5 90 205 10 30 13 60 230 10 30 13 60 255,5 10 35 14,5 125 278 12 35 14,5 125 305 12 40 17 155 338 13 40 17 155 385,5 13 50 21 150 445 13 50 21 150 490 13 60 28 175 547,5 18 60 28 185 597,5 18 60 28 285 726,5 18 HEPT HCT - - 31 35 40 45 50 56 63 - - - - - HGT HPX 25- 31- -- 35-35 40- 45-45 50-50 56-56 63-63 71-71 80-80 90-90 100 -100 -125 - 145 ACCESSORIES MS A BEHh MS-348 348 520 60 295 70 MS-393 393 565 60 320 70 MS-443 443 615 60 360 70 MS-493 493 665 60 410 70 MS-553 553 725 60 450 70 A BEHh MS-623 623 795 60 530 70 MS-701 701 875 60 590 90 MS-791 791 965 60 680 90 MS-891 891 1065 60 750 90 MS-991 991 1165 60 850 90 MS-1086 1086 1260 60 900 90 MS-1140 1140 1314 60 1000 90 MS-1240 1240 1414 60 1100 90 Model PA Adaptation plate to mount accessories on roof fans Features: • Used to mount PT, B, BTUB, BAC accessories. Allows fan to be separated from its base without dismantling accessories. A ØC DE HØO N A ØC DE HØO N PA-345 345 200 165 20 245 M.8 4x90º PA-890/630 890 690 629 20 750 M.10 12x30º PA-390 390 210 190 20 320 M.8 4x90º PA-890/560 890 620 559 20 750 M.10 12x30º PA-440/250 440 280 249 20 360 M.6 4x90º PA-990/630 990 690 629 20 850 M.10 12x30º PA-490 490 355 314 20 410 M.8 8x45º PA-990/710 990 770 709 20 850 M.10 16x22º30’ PA-550 550 395 354 20 450 M.6 8x45º PA-1085 1085 770 709 20 850 M.10 16x22º30’ PA-620 620 450 399 20 530 M.10 8x45 PA-1138/800 1138 860 799 25 1000 M.10 16x22º30’ PA-700/500 700 560 499 20 590 M.10 12x30º PA-1138/900 1138 970 899 25 1000 M.12 16x22º30’ PA-700/450 700 500 449 20 590 M.10 8x45º PA-1238 M.12 16x22º30’ PA-790 790 560 499 20 680 M.10 12x30º BS BSS PT 12381070 999 25 1100 146 ØA 220 240 310 435 600 730 810 B 150 150 150 200 280 355 400 Model BS BSS - 348 BS BSS - 393 BS BSS - 443 BS BSS - 493 BS BSS - 553 BS BSS - 623 BS BSS - 701 BS BSS - 791 BS BSS - 891 BS BSS - 991 BS BSS - 1086 BS BSS - 1140 BS BSS - 1240 PT-...-400 ØC 200 210 280 395 560 690 770 HT CHRE CHT HT CHRE PA-345 -- 722 PA-390 -- 825 PA-440/250 200/22525 1131 PA-490 -31 PA-550 250/315351135/1240 PA-620 -40 PA-700/500 400/450- 1445/1650 PA-700/450- 45 PA-790 -50 PA-890/630500 - PA-890/560- 56 PA-990/630- 63 PA-990/710- 71 PA-1085 560/630- PA-1138/800- 80 PA-1138/900- 90 PA-1238- 100 - High base plate and high base plate with silencer Automatic-closing shutters to work in vertical and horizontal position version 400, certified for 400ºC/2h PT-160 PT-180 PT-250 PT-355 PT-500 PT-630 PT-710 CHT MS-348-- 722 MS-393-- 825 MS-443 200/22525 1131 MS-493-31 MS-553 250/315351135/1240 MS-623-40 MS-701 400/450451445/1650 MS-791-50 MS-891 50056 MS-991 - 63/71MS-1086 560/630- MS-1140- 80/90 MS-1240- 100 - Features: • Used to facilitate on-site mounting of fans in ducts. Model Support frame to facilitate mounting on-site. ØD* ØO N CHT/CVT CHRE 160 10 4x90º 722 180 10 4x90º 825 250 10 4x90º 200/225 1131 355 10 8x45º 250/315 1135/1240 500 12 12x30º 400/450 1445/1650 630 12 12x30º 500 710 12 16x22º30’ 560/630 A B HE CHT/CVT HT CHRE 348 520 295 800 - - 733 393 565 320 800 - - 825 449 616 360 800 200/225 25 1131 493 665 410 800 - 31 554 724 450 800 250/315 35 1135/1240 623 795 530 800 - 40 706 876 590 900 400/450 45 1145-1650 791 965 680 900 - 50 896 1076 750 900 500 56 991 1165 850 900 - 63/71 1092 1272 900 900 560/630 - 1140 1314 1000 900 - 80/90 1240 1414 1100 900 - 100 - PT/H PT.../H-400 Ø A B ØC PT-450/H 540 254 500 PT-500/H 600 254 560 PT-560/H 660 254 620 PT-630/H 730 254 690 PT-710/H 810 254 770 PT-800/H 900 254 860 PT-900/H 1015 254 970 PT-1000/H 1115 254 1070 PT-1250/H 1365 254 1320 ØD* 460 514 560 640 710 800 900 1000 1250 E F 185 340 185 346 185 363 185 409 185 443 185 488 185 555 185 609 185736,5 ß Ø J 22º 30’ 12 15° 12 15° 12 15° 12 11°15’ 12 11°15’ 12 11°15’ 15 11°15’ 15 9° 15 N 8x45º 12x30º 12x30º 12x30º 16x22º30’ 16x22º30’ 16x22º30’ 16x22º30’ 20x18º ACCESSORIES OP Backdraught shutters for roof fans OP-25HT-25 OP-31HT-31 OP-35HT-35 REG OP-40HT-40 OP-45HT-45 OP-50HT-50 Model REG-80 REG-100 REG-112 REG-125 REG-140 REG-150 REG-160 REG-180 REG-200 REG-224 Record of manual regulation Features: • Their design allows them to be installed in ducting systems to adjust the airflow. S OP-56HT-56 OP-63HT-63 OP-71HT-71 LØD* 100 80 100 100 100 112 100 125 100 140 100 150 100 160 100 180 100 200 100 224 OP-80HT-80 OP-90HT-90 OP-100 HT-100 Model REG-250 REG-280 REG-315 REG-355 REG-400 REG-450 REG-500 REG-560 REG-630 REG-800 LØD* 100 250 100 280 100 315 100 355 100 400 150 450 150 500 150 560 250 630 250 800 Silencers to fit to inlet or outlet. Features: • Circular or rectangular silencers to fit to inlet or outlet on centrifugal or axial fans. INLET / OUTLET (Rectangular cross section) 100 100 b L SR-1000/900/900 SR-1200/900/900 SR-1400/1200/900 SR-1800/1200/1200 SR-1800/15001200 Replacement dampers (dB) on octave band (Hz) Applicable L a b Kg125250500 1000 20004000 HCH/HCT/THT-63 900 1000 900 64 4 10 21 37 44 37 HCH/HCT/THT-71 900 1200 900 74 4 10 21 37 44 37 HCH/HCT/THT-80 900 1400 1200 102 4 12 25 41 47 42 HCH/HCT/THT-90 1200 1800 1200 169 4 12 25 41 47 42 HCH/HCT/THT-100 1200 1800 1504 195 4 12 25 41 47 42 a l L l INLET / OUTLET (Circular cross section) SC-630/900 SC-710/900 SC-800/900 SC-900/1200 SC-1000/1200 L d1 d2 900 630 800 900 710 900 900 800 1000 1200 900 1120 1200 1000 1200 l d3 d4 d5 100 630 720 690 100 710 800 770 100 800 900 860 100 900 1000 970 100 1000 1100 1070 d6 12 12 12 15 15 n Kg 12x30º 44 16x22º30’ 65 16x22º30’ 70 16x22º30’ 87 16x22º30’ 95 d2 d1 d1 d4 d6(n) d5 Replacement dampers (dB) on octave band (Hz) 125 250 500100020004000 Applicable HCH/HCT/THT-63 5 8 14 12 13 9 HCH/HCT/THT-71 5 8 13 11 12 8 HCH/HCT/THT-80 4 8 11 9 9 8 HCH/HCT/THT-90 5 7 11 11 7 5 HCH/HCT/THT-100 4 7 11 10 7 6 L l d2 d3 d3 d4 d6(n) d5 INLET Replacement dampers (dB) on octave band (Hz) L d2 d3 d4 d5 d6 n Kg 12525050010002000 4000 Applicable S-160/600-A 600 260 160 220 200 10 4x90º 6 3 11 22 33 42 29 CHRE-722 S-180/600-A 600 300 180 240 210 10 4x90º 7 4 8 15 31 28 20 CHRE-825 S-250/600-A 600 450 250 310 280 10 4x90º 14 5 12 20 24 23 14 CVT-CHT-200/225 HT-25 / CHRE-1131 S-315/900-A 900 500 315 390 355 10 8x45º 22 4 12 21 26 19 15 HT-31 S-355/900-A 900 560 355 430 395 10 8x45º 25 4 12 20 24 18 14 CVT-CHT-250/315 HT-35 / CHRE-1135/1240 S-400/900-A 900 600 400 480 450 12 8x45º 29 5 12 19 22 18 13 HT-40 S-450/900-A 900 630 450 530 500 12 8x45º 32 5 12 18 20 16 12 HT-45 S-500/900-A 900 710 500 590 560 12 12x30º 35 4 11 18 16 14 11 CVT-CHT-400/450 HT-50 / CHRE-1445/1650 S-560/900-A 900 750 560 650 620 12 12x30º 41 4 10 16 14 13 10 HT-56 S-630/900-A 900 800 630 720 690 12 12x30º 44 5 8 14 12 13 9 CVT-CHT-500 / HT-63 S-710/900-A 900 900 710 800 770 1216x22º30’ 65 5 8 13 11 12 8 CVT-CHT-560/630 HT-71 S-800/900-A 900 1000 800 900 860 1216x22º30’ 70 4 8 11 9 9 8 HT-80 S-900/1200-A 1200 1120 900 1000 970 1216x22º30’ 85 5 7 11 11 7 6 HT-90 S-1000/1200-A 1200 1200 1000 1100 1070 1216x22º30’ 95 4 7 11 10 7 6 HT-100 147 ACCESSORIES MOTORS IE-2 Three-phase asynchronous motors Features: • Speeds: 2, 4, 6 and 8 poles • Three-phase power 230/400V 50Hz up to 5.5CV, and 400/690V 50Hz for greater power • Form of construction IM B3 (IM 1001) • Closed motors, with external ventilation (IC 411) • Degree of protection IP-55 • Class F insulation • S1 Service Electric regulations General prescriptions on electrical machines Marking of terminals and direction of rotation Start up characteristics of three-phase induction motors Insulating materials Standardised voltages Type of motor Power (kW) (CV) MOTOR-56 1-2T MOTOR-56 2-2T MOTOR-63 1-2T MOTOR-63 2-2T MOTOR-71 1-2T MOTOR-71 2-2T MOTOR-80 1-2T MOTOR-80 2-2T MOTOR-90S-2T MOTOR-90L-2T MOTOR-100L-2T MOTOR-112M-2T MOTOR-132S 1-2T MOTOR-132S 2-2T MOTOR-160M 1-2T MOTOR-160M 2-2T MOTOR-160L-2T 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 0.12 0.16 0.25 0.33 0.5 0.75 1 1.5 2 3 4 5.5 7.5 10 15 20 25 Speed (r/min) 2670 2730 2710 2710 2730 2760 2770 2770 2840 2840 2840 2880 2900 2920 2940 2940 2940 Regulations: • They fulfil the following international regulations: Mechanical regulations Dimensions and assigned power Degrees of protection (Code IP) Methods of refrigeration Forms of construction Noise maximum values Mechanical vibrations IEC/EN 60034-1 IEC 60034-8 IEC 60034-12 IEC 60085 IEC 60038 3000 r/min = 2 poles 50Hz On request: • Other forms of construction • Single-phase motors • Two-speed motors 1500 r/min = 4 poles 50Hz Type of motor Power (kW) (CV) MOTOR-56 1-4T MOTOR-56 2-4T MOTOR-63 1-4T MOTOR-63 2-4T MOTOR-71 1-4T MOTOR-71 2-4T MOTOR-80 1-4T MOTOR-80 2-4T MOTOR-90S-4T MOTOR-90L-4T MOTOR-100L 1-4T MOTOR-100L 2-4T MOTOR-112M-4T MOTOR-132S-4T MOTOR-132M-4T MOTOR-160M-4T MOTOR-160L-4T 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 11.00 15.00 Speed (r/min) 0.08 0.12 0.17 0.25 0.33 0.50 0.75 1.00 1.50 2.00 3.00 4.00 5.50 7.50 10.00 15.00 20.00 Voltage low 1000 r/min = 6 poles 50Hz Type of motor Power (kW) (CV) 1320 1320 1350 1350 1350 1370 1370 1380 1400 1400 1420 1420 1430 1450 1450 1460 1460 MOTOR-71 1-6T MOTOR-71 2-6T MOTOR-80 1-6T MOTOR-80 2-6T MOTOR-90S-6T MOTOR-90L-6T MOTOR-100L-6T MOTOR-112M-6T MOTOR-132S-6T MOTOR-132M 1-6T MOTOR-132M 2-6T MOTOR-160M-6T MOTOR-160L-6T 0.18 0.25 0.37 0.55 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 11.00 Voltage high Speed (r/min) 0.25 0.35 0.50 0.75 1.00 1.50 2.00 3.00 4.00 5.50 7.50 10.00 15.00 880 900 900 900 920 925 945 955 960 960 960 970 970 750 r/min = 8 poles 50Hz Type of motor Power (kW) (CV) MOTOR-80 1-8T MOTOR-80 2-8T MOTOR-90S-8T MOTOR-90L-8T MOTOR-100L 1-8T MOTOR-100L 2-8T MOTOR-112M-8T MOTOR-132S-8T MOTOR-132M-8T MOTOR-160M 1-8T MOTOR-160M 2-8T MOTOR-160L-8T Wiring diagram 0.18 0.25 0.37 0.55 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 0.25 0.33 0.50 0.75 1.00 1.50 2.00 3.00 4.00 5.50 7.50 10.00 Speed (r/min) 680 680 680 680 710 710 710 720 720 720 720 720 W F O Measurements G DB Model AC D K E C B H HD L A AA 148 IEC 60072 IEC/EN 60034-5 IEC/EN 60034-6 IEC/EN 60034-7 IEC/EN 60034-9 IEC 60034-14 H A B C D E F G DB K AAHD AC L O 56 56 90 71 36 9 20 3 7.2 M3 6x8.8 110 160 120 195 1-M16X1.5 63 63 100 80 40 11 23 4 8.5 M4 6x10 120 165 130 215 1-M16X1.5 71 71 112 90 45 14 30 5 M5 7x10 132 180 145 245 1-M20X1.5 80 80 125 100 50 19 40 6 15.5 M6 10x13 160 217 165 290 1-M20X1.5 90S 90 140 100 56 24 50 8 20 M8 10x13 175 230 185 310 1-M20X1.5 90L1/L2 90 140 125 56 24 50 8 20 M8 10x13 175 235 185 335/365 1-M20X1.5 100 100 160 140 63 28 60 8 24 M10 12x16 196 252 205 386 1-M20X1.5 112 112 190 140 70 28 60 8 24 M10 12x16 220 292 230 395 2-M25X1.5 132/S 132 216 140 89 38 80 10 33 M12 12x16 252 330 270 436 2-M25X1.5 132M/L 132 216 178 89 38 80 10 33 M12 12x16 252 325 270 475/500 2-M25X1.5 160M 160 254 210 108 42 110 12 37 M16 15x19 335 390 320 640 2-M32X1.5 160L 160 254 254 108 42 110 12 37 M16 15x19 335 390 320 640 2-M32X1.5 11 ACCESSORIES Intelligent sensors for controlling the fans Sensors which make it possible to sense certain environmental conditions and automatically start up the fans. This makes it possible to use the ventilation only when necessary. Using the sensors with the frequency inverters we can control the regime of operation of the fans, thus preventing the fan always working at its maximum consumption. These systems involve a significant energy saving. SI-PIR Motion detector Automatically activates the ventilation system when it detects the presence of people within its radius of action and keeps functioning for a pre-set time, which can be adjusted by means of an internal clock SI-PIR-TF-Cenital SI-PIR-TF-Mural Model SI-PIR Power Output Detection angle Adjustments Height installation Working temperature 230V 230V 360ºC Timing 5s-30 min 2.4-4.2 m -20ºC +50ºC SI-PIR-TFT-550-B 24V ac/24V dc 24V ac/24V dc 110ºC Timing 5s-30 min 1.8-3.6 m -20ºC +50ºC SI-PIR-TF-25-360 24V ac/24V dc 24V ac/24V dc 360ºC Timing 10s-30 min 2.4-4.2 m -20ºC +50ºC SI-SMOKE Tobacco smoke detector Automatically activates the ventilation system when tobacco smoke and other contaminants exceed the pre-set value in the sensor and keeps functioning for a pre-set time, which can be adjusted by means of an internal clock Model SI-SMOKE Power 220-240V ac Output 220-240V ac Maximum current (A) 3,0 Adjustments Timing 3min-20 min Height installation 1.5-2.0 m Working temperature -20ºC +50ºC SI-CO2 Air quality detector Automatically activates the ventilation system when the increase in contamination, as a function of the occupation of the premises, exceeds the pre-set value Model SI-CO2-GAQ24 Power 24V ac Output 0-10V ac Consumption (W) 5 Adjustments Timing 10s-30 min Height installation 1.5-2.5 m Working temperature -20ºC +50ºC SI-TEMP Temperature sensor Automatically activates the ventilation system when it detects a temperature greater than the pre-set value. Once the environmental temperature has descended below the pre-set point, the fan remains functioning for a pre-set period, which can be adjusted by means of the internal clock. The range of temperature oscillates between +10ºC and 40ºC Model SI-TEMP Power 220-240V ac Output 220-240V ac Maximum current (A) 3,0 Adjustments Timing 3min-20 min Height installation 1.5-2.0 m Working temperature +10ºC +40ºC 149 ACCESSORIES SI-TEMP+HUMEDAD Temperature and relative humidity sensor with display Independently controls the temperature and the relative humidity of the air on the premises. Automatically activates the ventilation system when it detects a temperature or humidity greater than the pre-set value. Once the environmental temperature or humidity has descended below the pre-set point, the fan remains functioning for a pre-set period, which can be adjusted by means of the internal clock. Power Model SI-TEMP+HUMEDAD Output 24V ac 0-10V dc Adjustments T = 0.5ºC and Height installation HR = 2% 1.5-2.5 m Working temperature +10ºC +40ºC SI-PRESIÓN Pressure transmitter Controls the pressure in installations with constant pressure ventilation, and transforms it into an electrical signal to regulate the ventilation system and constantly maintain the same pressure. Power Model Output Maximum consumption (VA) Connectors Pressure range SI-PRESIÓN TPDA 24V ac/24V dc 0-10V/4-20mA 4 6.2 mm 0-2500 Pa SI-PRESIÓN TPDA c/DISPLAY 24V ac/24V dc 0-10V/4-20mA 4 6.2 mm 0-2500 Pa SI-TIMER Timer Adjusts the operating time of the ventilation system to which it is connected. The ventilation system is automatically activated when the light switch goes on and continues to function for a pre-set time which can be altered by means of the internal clock Model SI-TIMER Power 220-240V ac Output 220-240V dc Maximum current (A) 3.0 Adjustments Working temperature Timing 3min-20 min -20ºC +50ºC SI-FUENTE DE ALIMENTACIÓN Power supply 24V dc / ac Powers the intelligent 24V dc/ac sensors from an input voltage of 230V. single-phase. SI-FUENTE DE ALIMENTACIÓN ac SI-FUENTE DE ALIMENTACIÓN dc Model SI-FUENTE DE ALIMENTACIÓN dc 150 Power Output Power (VA) 230 V 24V dc 30 SI-FUENTE DE ALIMENTACIÓN ac230/400 V. 24/48V ac 25 Alphabetical index of references CENTRIFUGAL CA-ROOF131 CHRE126 CHT121 CJHCH38 CTD129 CVT121 HBA99 HC14 HCD20 HCH27 HCH/SEC103 HCRE22 HCT27 HEP8 HEPT8 HFT27 HGI107 HGT57 HGTX57 HPX96 HPX/SEC101 HRE22 HT112 HTM94 HTP41 HTSOLAR134 HTTAL119 HTTI116 OVERPRESSURE KIT 108 RCH136 RCH-400x800VM136 TIRACAMINO133 VAC105 VAM105 Alphabetical index of references ACCESSORIES AD143 AET142 AR140 B145 BAC145 BS - BSS 146 BTUB144 C2V140 GMM142 GMP142 INT140 KME-10K142 MOTORS148 MS146 OP147 P143 P-400143 PA146 PL143 PS145 PT146 PT/H146 PT/H-400146 PV144 R144 REG147 RFM141 RFT141 RI141 RM140 RT144 S147 SI-CO2149 SI-FUENTE DE ALIMENTACIÓN 150 SI-PIR149 YES-PRESSURE150 SI-SMOKE149 SI-TEMP149 SI-TEMP+HUMEDAD150 SI-TIMER150 151 THE ErP DIRECTIVE MORE ECO-EFFICIENT FANS What does the new "ErP" directive refer to? The Ecodesing ErP 2009/125/CE Directive is going to encourage the economic and sustainable use of available energy resources. Its principal objectives are to encourage ecological design and to advance the struggle against climate change by means of the reduction of C02 emissions into the atmosphere. Over the next few years, the application of this directive will affect all products which require and consume energy so as to make them more environmentally friendly. • By the year 2020, the EU intends to fulfil its KYOTO commitment by increasing its consumption of renewable energies as opposed to those of fossil origin by 20%. • It is necessary to control and improve the quality of electrical devices by improving their performance through new, more efficient designs. For this reason, specific rules for each product marketed in the EU are being developed: Electric motors, water pumps, industrial and residential fans, transformers, etc... And for this purpose, a series of studies of the different categories of devices ordered by LOTS is being carried out, which is now resulting in the appearance of the first regulations, including those for fans. How will this ErP Directive affect fans? The first regulation of the Comission, (EU) 327/2011, which is the fruit of the study for the "LOT 11" category, has already been published. It is going to regulate non-residential fans with electrical power of between 125W and 500KW. This regulation sets down two phases for its complete implementation: • 1st phase: Beginning in January 2013, applying a first stage of efficiency for fans. • 2nd phase: Beginning in January 2015, these requirement levels will be further increased. These two phases are related with those already applied by Directive 2009/640/EC on the efficiency of standard electric motors which came into effect in June 2011. Since this time, Sodeca has been using IE2 efficiency motors in all its fans. In the second phase, starting in January 2015, all the electric motors used must satisfy IE3 efficiency. The only alternative is the use of IE2 motors + Inverter, or EC motors. The efficiency of fans will improve largely through the use of more efficient motors. However, improvements will also be introduced, by using the impellers which are best suited to each case, and through new, more highly optimised designs. As from each phase, products which do not comply with the stated requirement may not be sold and marketed in the European market. Are there any exceptions regarding the fans affected? Yes, at least for the category of fans included in LOT11, and apart from the products which may be regulated in the future in other categories which have not yet been finalised. The current regulations, (EU) 327/2011, corresponding to LOT11 already contemplate exceptions such as: • ATEX fans for explosive atmospheres. • Fans which are exclusively for emergency use (400ºC/2h, 300ºC/1h, etc...) • Fans which are specifically for working in environments at over 65ºC, or for transporting gases at over 100ºC. • Fans specifically for working in environments of gases transported at temperatures of below -40ºC. • Fans with motors at special voltages Vac>1000V or Vdc>1500V. • Fans for toxic, highly corrosive or inflammable environments. • Fans used for transporting non-gaseous substances (solids) in industrial processes. The possibility of being able to market fans which do not fulfil 327/2011 up to 1st January 2015 is also contemplated if they are intended to replace fans that are built into products marketed before 1st January 2013. And what about products exported to countries outside the EU? The directive is only required to be fulfilled within the EU. Must efficient fans be marked? Yes, because otherwise the breach of this directive would prevent CE marking. It should be clearly specified which products fulfil the requirements both in catalogues and in the selection programmes used. Will these fans be more expensive? Many of Sodeca's fans already satisfy the requirements of the directive. But in those cases in which the purchase price is significantly higher, the energy saving itself will allow you to recover your investment. And they are clearly much more economical in the long term. Sodeca is incorporating the latest new technology into high-efficiency IE2 and IE3 motors and EC systems with which many other advantages of regulation, communication and interaction with other pieces of equipment are going to be available. How do you calculate the efficiency objective? Regulation CE no. 327/2011 sets minimum efficiency requirements in two phases, the first one is applicable in 2013 and the second, more demanding one, in 2015. The efficiency objectives are determined according to the type of fan, the electrical power consumed at the point of maximum efficiency of the fan and the aerodynamic test type used. The degree of efficiency (N) is the value which takes the required efficiency for an input electrical power of 10 kW. N is different according to the type of test used and increases as it passes from the first to the second phase of application. For example, in an axial fan tested with a type C test, the value of N demanded for 2013 is 36% and for 2015 40%, as can be seen in the following graph. Objetive(%) Degree of efficiency 2015, N=40 Degree of efficiency 2013, N=36 Objetive for axial fans and type-C measurement 42% 40% 2015 38% 36% 2013 34% 32% 30% 28% 26% 24% 22% 0 2 4 6 8 10 12 14 16 Pe(d) (kW) 152 How do you calculate the efficiency of the fan? The performance of the fan is calculated at the point of optimum efficiency. This must be equal to or greater than the objective required. The method of calculation is different according to the elements which the fan includes and whether it is at final assembly or not. IF THE FAN IS SUPPLIED FOR ASSEMBLY Where, for the point of optimum efficiency: Electrical power Ped Hidraulic power Pus Losses Variator Losses Motor • • • • • Losses Losses Transmission Impeller IF THE FAN IS SUPPLIED COMPLETE a. If it does not have a speed inverter: b. If it has a speed inverter: Where, for the point of optimum efficiency: • ηe is the global efficiency. ηr is the efficiency of the turbine, Where Pu(s) is the gas power and Pa the mechanical power at the axis of the turbine. ηm is the efficiency of the motor. It is necessary to use motors which satisfy Regulation (CE) no. 640/2009 on motor efficiency. If the fan is supplied without motor or this is not covered by the by the motor regulations, it is possible to estimate its performance by calculation, according to the electrical input power recommended (Pe(kW)) for the point of optimum energy efficiency of the fan. In the following graphs, it is possible to observe these values by default. ηT is the efficiency of the transmission system. For fans with direct transmission, it is equal to 1. The transmission is considered to be of high efficiency when the width of the belt is equal to or greater than three times its height. Toothed belts and spur gears are also of high efficiency. Their performance can be estimated from the power of the axis of the turbine (Pa (kW)). For values of Pa of less than 1 kW and more than 5 kW, it is considered to be constant. See attached graph. Cm is the compensation factor to bear in mind the adaptation of the components. It is 0.9. CC is the compensation factor of the partial load. In the case of there is no speed regulator, it is 1. If there is a variator, it takes the same values as the fan at final assembly. 0,9 • Pu(s) is the gas power of the fan. • • • • ηe es la eficiencia global. Pe is the input electrical power for the supply. Ped is the input electrical power for the speed variator supply. CC is the compensation factor of the partial load. For Ped of more than 5 kW it is 1.04. For lower powers than 5 kW the factor is greater. See attached graph. 0,85 0,8 0,75 0,7 0,65 0,6 Cc 1,16 0,55 1,14 0,5 1,12 0 1 2 3 4 5 Pe (kW) 1,1 0,96 1,08 1,06 0,94 1,04 1,02 0,92 0 0,75 1,5 2,25 3 3,75 4,5 5,25 6 Ped (kW) 0,9 0,88 0,86 5 30 55 80 105 130 155 Pe (kW) Low efficiency High efficiency 1 0,98 0,96 0,94 0,92 0,9 0,88 0 1 2 3 4 5 6 Pa (kW) 153 In-line duct fans Axial fans Centrifugal fans Fans to extract smoke at 400ºC/2h – 300ºC/ 1h ATEX Fans for explosive atmospheres Roof fans Ventilation systems for houses Heat recuperators Filtration units Air curtains Efficient Energy Applications OUR PRODUCTS Ask for information Ventilation software. General Catalogue Crta. de Berga, km 0,7 E-08580 St. Quirze de Besora BARCELONA (Spain) Tel. +34 93 852 91 11 Fax.+34 93 852 90 42 comercial@sodeca.com Export sales: ventilation@sodeca.com www.sodeca.com NEW NEW FRANCE FIGUERES PUIGCERDÀ Ctra. de Berga, km 0,7 E-08580 SANT QUIRZE DE BESORA (Barcelona - Spain) Tel. +34 93 852 91 11 Fax +34 93 852 90 42 comercial@sodeca.com Export sales: ventilation@sodeca.com www.sodeca.com RIPOLL SANT QUIRZE DE BESORA GIRONA VIC Dir. LLEIDA ZARAGOZA MADRID MANRESA MOLLET REUS BARCELONA Dir. TARRAGONA Export Sales SODECA EXPORT Ctra. de Berga, km 0,7 E-08580 SANT QUIRZE DE BESORA Barcelona - SPAIN Tel. +34 93 852 91 11 Fax +34 93 852 90 42 ventilation@sodeca.com PORTUGAL Mr. Albert Bartés E-08580 SANT QUIRZE DE BESORA Barcelona - SPAIN Tel. +34 93 852 91 11 Fax +34 93 852 90 42 comercial@sodeca.com SODECA AMÉRICA USA - CANADÁ - MÉXICO AMÉRICA DEL SUR Mr. Francesc Bertran Sodeca Ventiladores Ltda Avda. Puerta Sur 03380 San Bernardo, SANTIAGO, CHILE ventas.chile@sodeca.com Tel. +56 (02) 2840 5582 SODECA CARIBBEAN AREA Mr. Carlos A. Hernández Gil Residencial Miramar Nº 120B-7ma Ave. Nº 1805 entre 18 y 20. Miramar Playa, CIUDAD DE LA HABANA, CUBA Tel. 00537 20 43721 sodeca@enet.cu Ctra. de Berga, km 0,7 E-08580 SANT QUIRZE DE BESORA (Barcelona - Spain) Tel. +34 93 852 91 11 Fax +34 93 852 90 42 comercial@sodeca.com Export sales: ventilation@sodeca.com Ref. 07/2013 www.sodeca.com
Similar documents
CKD CKDR CKD/EW CKDR/EW
twice the fan’s span plus the turbine’s diameter, with a minimum of 1.5 m. Sound power Lw(A) spectrum in dB(A) via frequency band in Hz. Values at maximum speed taken at outlet with average airflow...
More informationIN-LINE DUCT
Wall-mounted axial (HEP) and • HEPT: Sheet steel cased casing long-cased fans (HEPT), with • H EPT: Outside connecting box, fibreglass-reinforced plastic impeller. IP-65 protection
More informationcentrifugal fans and in-line duct extractors
FANS FOR EXPLOSIVE ATMOSPHERES AND OTHER APPLICATIONS
More informationReference system for Wire EDM machining. The standard range.
Can be adapted to automatic changing with 3R-W12-S Supplied with drawbar 3R-605.10 x2 Ready for code carrier holder 3R-U30638
More informationReference system for wire EDM machining. The
Reference element WEDM 3R-200.XJ-X Reference elements for machines with zero-line table. The length (L), hole spacing (C) and hole edge spacing (B) of the hardened reference elements are matched to...
More informationWire EDM Catalouge
normative unless this is expressly stated. Manufactured to meet System 3R’s quality requirements, but partly or completely made in a production plant that is not covered by System 3R’s ISO9000 cert...
More informationReference systems for electrode manufacturing
prevent instability and to achieve the necessary surface quality. Advantages of a damped chuck After intensive research into the dynamics of chuck systems, machine tool maker System 3R has develope...
More information