506-6200 LCT w/406-6200 Electronics
Transcription
506-6200 LCT w/406-6200 Electronics
The Leader of RF and Sonic Level For Assistance Call 1-800-527-6297 Outside North America + 215-674-1234 Installation and Operating Instructions Series 506-6200 Level Control Transmitter (LCT) using 406-6200 Electronics + 215-674-1234 Outside North America 1-800-553-9092 US and Canada www.drexelbrook.com drexelbrook.service@ametek.com Need More Instruction Books ? Go to www.drexelbrook.com Look under this specific product Download Instruction Manual AMETEK Drexelbrook makes no warranty of any kind with regard to the material contained in this manual, including, but not limited to, implied warranties or fitness for a particular purpose. Drexelbrook shall not be liable for errors contained herein or for incidental or consequential damages in connection with the performance or use of material. Copyright 2002 AMETEK Drexelbrook EDO #11-02-248 506-6200-LM Series 506-6200 Level Control Transmitter (LCT) using 406-6200 Electronics DREXELBROOK An ISO 9001 Certified Company 205 Keith Valley Road Horsham, PA 19044 US Sales 1-800-553-9092 24 Hour Service 1-800-527-6297 International + 215-674-1234 Fax + 215-674-2731 E-mail drexelbrook.info@ametek.com Web www.drexelbrook.com EDO #11-02-248 506-6200-LM Table of Contents Section 1.0 Introduction ................................................................................................. 3 1.1 System Description ................................................................................................... 3 1.2 Verify System Description ......................................................................................... 4 1.2.1 Circuit Description ........................................................................................ 4 1.3 Models Available ...................................................................................................... 4 1.3.1 Electronic Units ............................................................................................ 4 1.3.2 Connecting Cables ....................................................................................... 5 1.3.3 Sensing Elements ........................................................................................ 5 1.3.4 Verify System ................................................................................................ 5 Section 2.0 Specifications and Intrinsic Safety ............................................................ 6 2.1 Electronic Unit .......................................................................................................... 6 2.2 Verify System ............................................................................................................ 6 2.3 Three-Terminal Connecting Cables .......................................................................... 7 2.4 Sensing Elements .................................................................................................... 7 Section 3.0 Theory of Operation ................................................................................... 8 3.1 Electronic Unit .......................................................................................................... 8 3.2 Cote-Shield Action ................................................................................................... 9 3.3 Sensing Element ...................................................................................................... 9 3.4 Connecting Cables ................................................................................................... 10 3.5 Verify System (optional) ............................................................................................ 10 Section 4.0 Installation ................................................................................................... 12 4.1 Unpacking ................................................................................................................ 12 4.2 Mounting the Electronic Unit ..................................................................................... 12 4.2.1 Installation Location and Approval Codes .................................................... 12 4.3 Mounting the Sensing Element ................................................................................. 13 4.3.1 Flush Sensing Element ................................................................................ 14 4.4 Mounting the Verify System ...................................................................................... 15 4.5 Wiring the Electronic Unit ......................................................................................... 15 4.6 Wiring the Sensing Element ..................................................................................... 16 4.7 Wiring the Verify System ........................................................................................... 17 Table of Contents (continued) Section 5.0 Calibration/Operation ................................................................................. 18 5.1 Start-up ..................................................................................................................... 18 5.2 Controls and Adjustments ........................................................................................ 18 5.2.1 Setpoint Adjustment without Verify System ................................................... 18 5.2.2 Setpoint Adjustment with Verify System ........................................................ 18 5.2.3 Time Delay Control ...................................................................................... 18 5.2.4 Fail-Safe Selector ......................................................................................... 19 5.3 Calibration Procedures ............................................................................................. 19 5.3.1 Calibration of Horizontal Sensing Elements ................................................. 19 5.3.2 Calibration of Vertical Sensing Elements ..................................................... 21 5.3.3 Emergency Method of Calibration ................................................................ 21 5.3.4 Calibration of Time Delay Units .................................................................... 21 5.3.5 Calibration of Flush Sensing Element .......................................................... 22 5.4 Recalibration ............................................................................................................ 23 5.5 Calibrating with Verify System .................................................................................. 23 Section 6.0 Troubleshooting ........................................................................................... 24 6.1 Introduction ............................................................................................................... 24 6.2 Testing the LCT Electronics ...................................................................................... 24 6.3 Testing the LCT Electronics with Verify ..................................................................... 24 6.4 Testing the Cote-ShieldTM Sensing Element .............................................................. 25 6.4.1 Level Below the Sensing Element ................................................................ 25 6.4.2 Level Above the Sensing Element ............................................................... 26 6.5 Checking the Sensing Element Cable ...................................................................... 27 6.6 Possible Problems with Probable Causes ................................................................ 28 Section 7.0 Factory Support ........................................................................................... 29 7.1 Factory Assistance ................................................................................................... 29 7.2 Field Service ............................................................................................................ 29 7.3 Customer Training ..................................................................................................... 29 7.4 Equipment Return ......................................................................................................30 Appendix A Shortening or Lenghtening Sensing Element Appendix B FM & CSA Control Drawings Page 5A Hold here while tightening condulet. Hold here to install or remove sensing element from vessel. Packing Gland CONDULET Assembly Do Not Disturb! WRONG Allows Moisture Infiltration WRONG silicone sealant. * CORRECT CONDUIT BREATHER DRAIN CORRECT *Fill Pipe Ends with Use only cable supplied by AMETEK Drexelbrook * All conduit connections are sealed. Gaskets are in place. Installation 4.4 Mounting the Verify System: 401-10-220 Pulse Recognition Module 401_10_210 Verify Switch Module For mounting, see Figures 4-4 and 5-5. The 401-10-220 pulse recognition module is mounted directly onto the 406-6200 Series transmitter on the power/signal connection side. The 401-210 Verify Switch module can be mounted on a standard 35mm DIN rail or screw-mounted to a panel. Pulse Module Assembly 406-6200 Series Transmitter GND (Green) Shield B (Red) Pad A (Black) 4.5 Wiring the Electronic Unit Note: The electronic unit has a grounding link between the ground and common terminals. The link is reqired for hazardous area operation and should not be removed before consulting the factory. All signal and power connections are made to the terminal strip on the 406-6200 Series chassis. These connections are (+), (-), comm, and ground. See Figure 4-6. If signal wires cannot be referenced to circuit ground, please consult factory. The sensing element cable connections are made to the back of the instrument chassis. These connections are labled ground (GND), shield (SH), and center wire (CW). See Figure 4-7. Wiring to PLC or DCS w/ Non-isolated Inputs The negative side of loop is grounded to the chassis (housing) at the electronic unit. If connecting this product to an instrument that is grounded OTHER THAN at the negative input terminal, contact Drexelbrook Service Department at 1-800-527-6297 (US & Canada; all others call 1-215-674-1234). Signal Wiring (Typical) Pad B (Blue) Fig. 4-4 Mounting the 401-10-220 Pulse Recognition Module For wiring diagrams with With Verify System, see Figures 4-10 and 4-11 Fig. 4-6 Signal Wiring to Electronic Unit 3.56 (90) 2.68 (68) 2.18 (55.3) Ground Wire (Green) Module mounts to standard 36mm DIN rail Fig. 4-5 Mounting the 401-10-210 Verify Switch Module Fig. 4-7 Sensing Element Connections to the Electronic Unit Shield Wire (Red) Center Wire (Blue) 7.0 Factory Support 7.1 Factory Assistance AMETEK Drexelbrook can answer any questions about your level measurement system. Call Customer Service at 1-800-553-9092 (US and Canada) , or + 215-674-1234 (International). If you require assistance and attempts to locate the problem have failed: • Contact your local Drexelbrook representative, • Call the Service department toll-free at 1-800-527-6297 (US and Canada) or + 215-674-1234 (International), • FAX the Service department at + 215-443-5117, or • E-Mail to drexelbrook.service@ametek.com Please provide the following information: Instrument Model Number ___________________________ Sensing Element Model Number and Length ___________ Original Purchase Order Number _____________________ Material being measured _____________________________ Temperature __________________________________ Pressure ______________________________________ Agitation ______________________________________ Brief description of the problem _______________________ ____________________________________________________ ____________________________________________________ Checkout procedures that have failed __________________ ____________________________________________________ ____________________________________________________ 7.2 Field Service Trained field servicemen are available on a time-plus-expense basis to assist in start-ups, diagnosing difficult application problems, or in-plant training of personnel. Contact the service department for further details. 7.3 Customer Training Periodically, AMETEK Drexelbrook instrument training seminars for customers are held at the factory. These sessions are guided by Drexelbrook engineers and specialists, and provide detailed information on all aspects of level measurement, including theory and practice of instrument operation. For more information about these valuable workshops, write to AMETEK Drexelbrook, attention: Communications/ Training Group, or call direct + 215-674-1234. 506-6200-LM/Pg.29 7.4 Equipment Return In order to provide the best service, any equipment being returned for repair or credit must be pre-approved by the factory. In many applications, sensing elements are exposed to hazardous materials. • OSHA mandates that our employees be informed and protected from hazardous chemicals. • Material Safety Data Sheets (MSDS) listing the hazardous materials to which the sensing element has been exposed MUST accompany any repair. • It is your responsibility to fully disclose all chemicals and decontaminate the sensing element. To obtain a return authorization (RA#) , contact the Service department at 1-800-527-6297 (US and Canada) or + 215-674-1234 (International). Please provide the following information: Model Number of Return Equipment ____________________ Serial Number _________________________________________ Original Purchase Order Number _______________________ Process Materials that equipment has been exposed to _____________________________________________________ MSDS sheets for any hazardous materials Billing Address ________________________________________ ______________________________________________________ Shipping Address ______________________________________ ______________________________________________________ Purchase Order Number for Repairs _____________________ Please include a purchase order even if the repair is under warranty. If repair is covered under warranty, you will not be charged. Ship equipment freight prepaid to: AMETEK-DREXELBROOK. 205 KEITH VALLEY ROAD HORSHAM, PA 19044-1499 COD shipments will not be accepted. 506-6200-LM/Pg.30 APPENDIX A Shortening or Lengthening Sensing Element CAUTION: The insulation length of either Flush Sensing Elements or Insulated Sensing Elements can NOT be changed. Cable sensing elements can only be shortened and instructions are included with each unit. Insulators The Need Sometimes your application calls for probe lengths other than the standard 18-inch or longer insertion lengths supplied. Shortening the sensing element is quite simple and can be done in the field. Lengthening the sensing element, however, is more difficult because the metal rod, typically 304SS or 316SS, must be welded. Before making any Adjustments: 1) Read the following instructions thoroughly. 2) Remove Power 3) Disconnect the electronics. 4) Protect electronics from any static discharge. 5) Protect electronics from any heat. Shortening The bare metal center rod of the sensing element can be shortened with a hacksaw. Be careful not to cut either of the two insulators. See Figure on this page. Note: Cote-Shield element must In applications using conductive or water-based materials, NEVER be shortening is not a problem. Leave a minimum bare Modified! Insertion Length (18" or 36" std.) metal center rod length of two (2) inches. Center Rod Note: Any changes to probe length after calibration requires recalibration to insure proper operation! For dry granular materials, such as powder, sand, corn, clinker, etc., you must leave a minimum bare metal center rod length of eight (8) inches. Consult the factory before shortening beyond this point. Lengthening To lengthen the sensing element, an extension rod can be welded onto the end of the bare metal center rod. Make sure that the extension rod is the same metal as the sensing element. An alternate option is to add a pipe coupling and a section of metal pipe after threading the tip of the sensing element. In this case, the metal pipe need not be identical to the metal of the sensing element. A-1 506-6200 Series LCT APPENDIX B APPROVAL DRAWINGS These drawings are on the the pages following this sheet: CSA Control Drawings for 406-6200 Series Transmitter 420-0001-588-CD FM Control Drawings for 406-6200 Series Transmitte 420-0001-813-CD C-1 DREXELBROOK An ISO 9001 Certified Company 205 Keith Valley Road Horsham, PA 19044 US Sales 1-800-553-9092 24 Hour Service 1-800-527-6297 International + 215-674-1234 Fax + 215-674-2731 E-mail drexelbrook.info@ametek.com Web www.drexelbrook.com
Similar documents
DREXELBROOK®
A 10 inch/254mm Note: B 3.5 inch/88.9mm Cote-Shield should extend through Nozzle + C 2 inch/51mm Typical "Wall Buildup" + 2 Inches Insertion Length (IL) A 6 inch/152mm B 12 inch/305mm C 18 inch/4...
More informationZ-Tron III Level Control - Electrical Solutions Corp
AMETEK Drexelbrook makes no warranty of any kind with regard to the material contained in this manual, including, but not limited to, implied warranties or fitness for a particular purpose. Drexel...
More information