Welcome to Dr. Ram Manohar Lohia Institute of Medical Sciences
Transcription
Welcome to Dr. Ram Manohar Lohia Institute of Medical Sciences
DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHOOTI KHAND , GOMTI NAGAR, LUCKNOW- 226 010 Phones: 0522-4918502, 4918505,Fax 0522-4918506 Website : www.rmlims.in TENDER DOCUMENT Ref. No. RMLIMS/MM(eq)/14-15/3745 Date:- 26.12.2014 Tender Notice Sealed fresh tenders are invited from manufacturers/Direct importers/authorized distributors and Agents for the supply of equipment for various departments viz, Emergency Medicine (Portable USG, Incubator, Transport Monitor, Arthroscopy Set General Instruments, X-Ray Machine etc.), Nuclear Medicine (128 Slice PET CT ) and Pathology (Micro Tissue Array) etc. for superspecialities. Details information like list of items, & their specification, earnest money deposit etc. can be downloaded from our website www.rmlims.in/www.drrmlims.ac.in and submitted with a demand draft of [Rs. 1000.00 + VAT @ 5% =1,050.00](NonRefundable). Quantity may increase or decrease in future. Start date of download of tender documents is 29.12.2014 and Last date of download of tender documents is 16.01.2015 Director DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Letter No. RMLIMS/MM(eq)/14-15/ Date: 12.2014 ACKNOWLEDGEMENT M/s................................................... ........................................................ ......................................................... Subject :- Tender Documents. Dear Sir, In reference to Tender No. RMLIMS/MM(eq)/14-15/3745 dated 26.12.2014. We acknowledge the receipt of Rs. 1,050.00 (inclusive VAT) vide D.D. No. ................................ Dated.......................Bank ................................Branch .............................. towards cost of tender documents. We are pleased to forward you a set of tender documents consisting of the following:- Please acknowledge the receipt. Thanking You, For Director DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Notice against Tender-Adv. No. RMLIMS/MM(eq)/14-15/3745 Date:-26.12.2014 Sealed fresh offers are invited from reputed manufacturer/Direct Importers/Authorized Distributors/ Authorized Agents for the supply of following equipments as per conditions stipulated in the tender documents: Sr. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 Name of Department Deptt. of Emergency Deptt. of Pathology Deptt. of Nuclear Medicine Name of Equipment Portable USG (Fast Screening) MRI Compatible Infusion Pumps Incubator Transport Monitor Anesthesia Work Stations Cautery Machine General Instrument Set Trauma Set Micro Trauma Set Arthroscopy Set X-Ray Machine Tissue Micro Array 128 Slice PET-CT Qty. 01 02 04 04 01 02 04 set 04 set 04 set 02 set 01 01 01 Earnest money 18,000.00 12,000.00 20,000.00 24,000.00 30,000.00 10,000.00 20,000.00 80,000.00 80,000.00 80,000.00 15,000.00 40,000.00 15,00,000.00 The tender document may download from the institute's website & submitted with a Demand Draft of [Rs. 1,050 (Rs. One Thousand fifty only) {inclusive VAT} (Non-Refundable)]. Last date of download of tender document from website is 16.01.2015. The downloaded tender forms must accompany Demand Draft issued to prior or till 16.01.2015. The duly filled tender documents will be received till 5:00 P.M on 16.01.2015 in the JDMM camp, Ground floor of the Institute in two bid system i.e. technical bid & price bid, in the hard copy and soft copy in MS Excel Sheet, be kept separately. Quantity may increase or decrease in future. Sealed Tenders should be submitted in a two-bid system i.e. technical offer & price bid (two identical copies of each). One copy of Technical Bid shall be sealed in one envelop and another copy of Technical Bid shall be sealed in another envelop and both the copies shall be sealed i n a big envelop and in the same manner one copy of Price bid shall be sealed in one envelop and another copy of Price bid shall be sealed in another envelop and both the copies shall be sealed in a big envelop. In the fifth envelop Earnest Money draft and cost of Tender Document is to be kept. All the Five envelops shall be kept in a larger envelop which is to be then sealed & posted or got received in the Institute. Tender Form has to be purchased for each item. The tender document along with Earnest Money Deposit (Refundable) for respective tenders as indicated against each item may be enclosed separately with tender documents. The Demand Draft from a Nationalized Bank towards Earnest Money should be in favor of the "Finance Controller, RMLIMS, Lucknow" payable at Lucknow. Bids will be opened in the presence of authorized representative of the bidders on scheduled date & time. The Technical bid will be opened at 12:00 P.M on 19.01.2015. Date for opening of financial bid for all rest items will be decided after opening of technical bid. If last date of the tender submission is observed as holiday, the next working day will be treated as last date. Any legal dispute for whatever reason shall be subject to the legal jurisdiction of a court of law of Lucknow (U.P) India. The Director reserves the right to accept or reject any or all tender in part or full without assigning any reason thereof. The Institute will not be responsible for any postal delay. Detailed information & specifications may be downloaded from website of the institution www.rmlims.in/www.rmlims.ac.in DIRECTOR DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Tender Form No. RMLIMS/MM(eq)/14-15/ Dated: / /2014 Cost of Tender: Rs. 1,050.00 (inclusive VAT@5%) Notice Tender-Adv. No. RMLIMS/MM(eq)/14-15/3745 Date:-26.12.2014 NAME OF EQUIPMENT __________________________________________________________ EARNEST MONEY Rs.___________________________________________________________ START DATE FOR DOWNLOAD OF TENDER DOCUMENT: 29.12.2014 LAST DATE FOR DOWNLOAD OF TENDER DOCUMENT: 16.01.2015 LAST DATE FOR SUBMISSION OF TENDER DOCUMENT 16.01.2015 TILL 5:00 P.M. DATE FOR OPENING OF TECHNICAL BID (FOR PMR): 19.01.2015 at 12:00 PM. ONLY TECHNICALLY QUALIFIED TENDERER'S FINANCIAL BID WILL BE OPENED ON THE DATE FIXED BY THE DIRECTOR, RMLIMS, GOMTI NAGAR, LUCKNOW. The tender no. and the name of the item must be superscribed on the top of the larger envelop. The tender document along with Earnest Money Deposit (Refundable) for respective tenders as indicated against each item may be enclosed separately with tender documents. Quantity may increase or decrease in future. Sealed Tenders should be submitted in a two-bid system i.e. technical offer & price bid (two identical copies of each). One copy of Technical Bid shall be sealed in one envelop and another copy of Technical Bid shall be sealed in another envelop and both the copies shall be sealed in a big envelop and in the same manner one copy of Price bid shall be sealed in one envelop and another copy of Price bid shall be sealed in another envelop and both the copies shall be sealed in a big envelop. In the fifth envelop Earnest Money draft and cost of Tender Document is to be kept. All the Five envelops shall be kept in a larger envelop which is to be then sealed & posted or got received in the Institute. The Demand Draft from a Nationalized Bank towards Earnest Money should be in favour of the "Finance Controller, RMLIMS, Lucknow" payable at Lucknow. Bids will be opened in the presence of authorized representative of the bidders on scheduled date & time. Date for opening of financial bid will be decided after opening of technical bid. If last date of the tender submission is observed as holiday, the next working day will be treated as last date. Any legal dispute for whatever reason shall be subject to the legal jurisdiction of a court of law of Lucknow (U.P) India. The Director reserves the right to accept or reject any or all tender in part or full without assigning any reason thereof. The Institute will not be responsible for any postal delay. Director DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TENDER DOCUMENT GENERAL TERMS & CONDITIONS FOR NOTICE INVITING TENDER NO RMLIMS/PURCHASEMM(eq)/ 14-15/3745 The following terms & conditions should be complied with while submitting the tender:1. Tender should be submitted to the JD (MM) office or Director Camp located at Ground Floor of the Administrative Building, Ram Manohar Lohia Institute of Medical Sciences, Vibhuti Khand Gomti Nagar, Lucknow 226010, UP, INDIA under the sealed cover failing which the tender shall be disqualified. 2. The tender terms and conditions be clearly typed or legibly written giving the full name and address of the tenderers. The tenderers should quote in figures as well as in words the rates and amount tendered by him/them. Alteration, if any, unless legible and attested by the tenderers, with their full signature, shall invalidate the tender. The tender should be signed by the tenderers himself/themselves or him/their authorized agent on his/their behalf. In case the tender is signed by the agent the authority letter in his favour shall be enclosed with tender documents. 3. VAT Registration certificate duly attested copy by a Gazzetted Officer should also be enclosed. VAT, Income Tax clearance certificate along with the affidavit from a notary that the firm has never been black listed must be attached along with the tender failing which the tender will be rejected and no correspondence will be entertained in this regard. Tenderers hereby agree to all terms and conditions stipulated in N.I.T. and undertake to sign the rate Contract or Supply order within the given days from the date of order failing which Security shall be liable to be forfeited. The manufacturer or their Indian representative will ensure proper after sales service as per our requirements from time to time, against the guarantee/warranty clause as per the terms and conditions agreed under negotiations would be provided at our Institute without fail. Any negligence on this account shall be the sole responsibility of foreign vendor as well as Indian Agent and the liability for compensation will be fixed up by Director,Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow. 4. Sealed Tenders should be submitted in a two-bid system i.e. technical offer & price bid (two identical copies of each). One copy of Technical Bid shall be sealed in one envelop and another copy of Technical Bid shall be sealed in another envelop and both the copies shall be sealed in a big envelop and in the same manner one copy of Price bid shall be sealed in one envelop and another copy of Price bid shall be sealed in another envelop and both the copies shall be sealed in a big envelop. In the fifth envelop Earnest Money draft and cost of Tender Document is to be kept. All the Five envelops shall be kept in a larger envelop which is to be then sealed & posted or got received in the Institute. Separate Tender Form has to be purchased for each Item. 5. The tenderers should take care that the rates and amounts are written in such a way that interpolation is not possible. No blank space should be left, which would otherwise make the tender liable for rejection. 6. All Quotes shall be FOR DRRMLIMS. Delivery schedule with definite date of delivery at destination (taking into cognizance of transit facilities) must be indicated. This contractual delivery date/period should be inclusive of all the lead-time. Page 1 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 7. The tenderers should clearly state whether he/they are manufacturer, accredited agents, or sole representative (indicating the name of Principal) on the top of the Bid and the authority letter must be attached with technical bid, but authorization as Agent/Distributor/Representative for this tender only will not be accepted.” 8. The tenderers submitting his/her tender would be deemed to have considered and accepted all the terms and conditions. No Enquiries, verbal or written, shall be entertained in respect of acceptance or rejection of the tender. 9. The offer shall be unconditional. Any conditional price bid will not be entertained and the tender will be treated as cancelled. 10. The quantity shown in the Schedule may be increased or decreased to any extent depending upon the actual requirement. 11. The tenderer shall specify regarding after sales services within the Guarantee/Warranty period. 12. (a) The tenderer shall also confirm the Installation, Commissioning, Demonstration and Training to the concerned persons of this Institute. 12. (b) The Institute reserves the right to reject or accept the tender after reviewing the previous experience to the services given by the vendor in the equipment already supplied by him. 13. The tenderer shall submit the pre-requisite information like Civil works/Electrical details etc. within 2 weeks from the date of receipt of order or establishment of letter of credit as the case may be, if not asked for in the tender itself. 14. The Institute reserves the right to cancel/reject in full or any part of the tender which generally do not fulfill the conditions stipulated in the tender without assigning any reason. 15. The Tenderer shall quote for the latest model of their machine available within required technical specification. 16. Any action on the part of the tenderer to influence anybody of the Institute will make his/their tender liable to rejection. 17. The tenderers shall submit the offer in original copy of the tender documents duly signed on each page. Item-wise rates may be indicated on letter head of the firm (If any taxes are require, please write clearly percentage) . 18. In the case of placement of Purchase Order, the vendor (the tenderers whose tender is accepted) shall have to confirm the purchase order within 7 days from the date of the dispatch of purchase order otherwise it will be deemed that offer is acceptable to the firm. Notwithstanding any other provision, the terms & conditions and any other items given in the Purchase order will be treated as binding with “Errors & omission excepted” basis. However, if the supplier notices any discrepancy in the order, he/ they must bring the same to the notice of the Institute and seek clarifications. Supplier will have to bear the responsibility for failure to take this action. 19. The Institute may, in writing, make any revision or change in the purchase order including additions or subtractions from the quantities originally ordered in the specifications or drawings. If any such revisions/changes affect the price or delivery, the same shall be subject to the adjustment of price/delivery, where required on a reasonable basis by mutual agreement in writing which should be communicated. Page 2 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 20. PBG:- The tenderer shall also furnish performance bank guarantee of @15% of the order value before Taxes or (FOB) value at the time of shipment or supply of goods and this will be released after the successful completion of warranty period ( The Period of PBG will start from Date of Installation of the Machine to the Date of end of Warranty Period ). 21. The Institute reserves the right to cancel the purchase order or any part thereof and shall be entitled to revise the contract wholly or in part by a written notice to the vendor, if;The Vendor fails to comply with the terms of the purchase order including specifications and other technical requirement. a. b. c. The vendor becomes bankrupt or goes into liquidation The vendor fails to deliver the goods in time and or does not replace the rejected goods promptly. A receiver is appointed for any of the property owned by the vendor. 22. Upon receipt of the said cancellation notice, the vendor shall discontinue all works of the purchase order and matters connected with it. 23. Earnest Money be paid in shape of DD, TDR, FDR, drawn in favour of the "Finance Controller, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow", payable at Lucknow, U.P. India as mentioned in the tender notification. 24. Unless otherwise specified in the order, the order price shall remain firm and will not be subject to escalation of any description during the pendency of the order, notwithstanding the change in the cost of materials, labour and/or variations in taxes, duties and other levies on raw materials and components may take place while the order is under execution even if the execution of the order is delayed beyond the completion date specified in the order for any reason whatsoever. 25. The price should be on F.O.R. RMLIMS basis inclusive of all levies and duties wherever applicable which should be indicated clearly. The rates of VAT should be clearly indicated wherever chargeable. The RMLIMS is not eligible to issue „C‟ or „D‟ Form, of U.P. commercial tax department however the concessional rate of Central Sales Tax admissible to Research Institutions on purchase of Scientific Instruments/Equipments etc. from certain States like Maharashtra, Delhi, West Bengal etc. is applicable to this Institute.(Please quote price in Format enclosed as annexure-C) 26. Prices will be quoted on F.O.B. as well as estimated CIP New Delhi basis for imported goods, Indian Agency commission/rebate payable to Indian Agent, if any, shall be shown separately and that will be payable in equivalent rupee directly to Indian Agent .The Indian Agency commission will be calculated on the exchange rate prevailing on the last date of submission of Tender. The Tenderer must quote the taxes levied, if any, on the Indian Agency commission. The supplier shall be responsible to get the goods air –freighted/sea freighted & air insured/marine insured up to the Institute. (Please quote price in Format enclosed as annexure-D) 27. Declare separately the FOB and CIP prices. 28. The offer of the tenders shall remain valid for a period of at least 180 days from the date of opening of the tender. 29. All goods or materials shall be supplied by the tenderers whose tender is accepted, strictly in accordance with the specifications, drawings, data sheets, other attachments and conditions stated. Any alterations of those conditions shall not be made without the consent of the Institute in writing which must be obtained before any work against the order is commenced. All material furnished by the seller pursuant to this order (irrespective of whether engineering, design data or other information has been furnished, reviewed Page 3 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 or approved by the Institute) will be guaranteed to the best quality of their respective kind (unless otherwise specifically authorized in writing by the Institute) and shall be free from faulty design ( to the extent such design is not furnished to the Institute) workmanship and materials, and to be of sufficient size and capacity and of proper materials so as to fulfill in all respects with all operating conditions, if any, specified in this order. 30. The Equipment supplied shall carry a warranty of 60 months from the date of satisfactory Installation and commissioning of the equipment. If any trouble or defect originating with the design, materials, workmanship or operating characteristics of any materials arise at any time from the date of Installation, the same shall as promptly as possible make such alteration, repairs and replacement as soon as notified thereof, the seller shall at his own expenses and as promptly as may be necessary to permit the materials function in accordance with the specification and to fulfill the foregoing guarantee/warranty. 31. The Institute may at its option, remove such defective materials at the seller‟s expense in which event the seller shall, without any cost of the RMLIMS and as promptly as possible, furnish and install proper materials, repaired or replaced materials shall be similarly guaranteed for a period of not less than 30(thirty) months from the date of shipment. 32. In the event that the materials supplied do not meet the specifications and are not in accordance with the drawings, data sheets or the terms of this order, rectification is required at site, the RMLIMS shall notify to the seller giving full details of differences. The seller shall attend the site, within seven days of receipt of such notice, meet the representative of the RMLIMS and action required to correct the deficiency. 33. If the seller fails to attend the fault within the prescribed time the Dr. RMLIMS, Lucknow shall immediately get the same rectified on costs of the seller/supplier. 34. Payment Terms : In case of Indian goods, 100% payments may be released within 30 days from the date of satisfactory installation. In case of imported goods/equipment, the payment schedule will be as follows. A75% against shipment B- 25% against satisfactory installation 35. The mode of payment will be through irrevocable letter of credit. However, Indian Agency Commission or Technical Services charges would be paid in Indian rupee after satisfactory receipt & installation of goods at site. Indian Agency Commission will be declared in the price/bid. If Indian agency commission is not mentioned in the price bid no claim for it shall be admissible after ward. 36. Delivery Time as mentioned in Purchase order shall be the essence of the order and no variation shall be permitted except with prior authorization in writing from the Purchaser. 37. In the event of delay in making delivery on the part of the vendor, it will be at purchaser‟s discretion to receive delivery with a reduction in price of the article/or equipment. 38. Force majeure shall mean and be limited to the following: Any war/hostilities Page 4 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 1 Any riot or civil Communication Any earthquake, flood, tempest, lightning or other natural disaster Any strike, or lock-out (only those exceeding ten continuous day in duration) or other conditions affecting the performance of the seller‟s obligations. The seller shall advise the RMLIMS by registered letter duly certified by Local Chamber of Commerce of Statuary authorities the beginning and end of the above causes of delay within 7(seven) days of occurrence and cessation of such Force Majeure conditions, in the event of delay lasting over one month, if arising our causes of Force Majeure, the RMLIMS reserves the right to cancel the order and the provisions governing termination state under articles shall apply. For delays arising out of Force Majeure, the seller shall not claim extension in completion date for a period exceeding the period of delay attributable to the causes of Force Majeure and neither the RMLIMS nor the seller shall be liable to pay extra costs provided it is Mutually established that Force Majeure conditions did actually exist. The seller shall categorically specify the extent of Force Majeure conditions prevalent in his works (such as power restriction etc.) at the time of submitting the bid and whether the same have taken into consideration or not in the quotations. In the event of delay in delivery and/or unsatisfactory manufacturing progress and supply, the RMLIMS has the right to cancel the purchase order as whole or in part without liability of cancellation charges. In the event of rejection of non-conforming goods the vendor shall be allowed, without any extension of delivery time to correct the non-conformities, should however the vendor fail to do so within stipulated time, the RMLIMS may cancel the order. 39. No payment shall be made for rejected material nor would the tenderer be entitled to claim for such items. 40. Rejected items would be removed by the tenderer from the site within two weeks of the date of rejection at their own cost. In case they are not removed they will be auctioned at the risk and responsibilities of the suppliers without any further notice. 41. Penalty Clause :(A) In the case of not honoring the supply order, Ram Manohar Lohia Institute of Medical Sciences, will forfeit his EMD. (B) In the case of non-supply of stores within stipulated period, in case of indigenous goods it will be at the discretion of the Ram Manohar Lohia Institute of Medical Sciences to accept delivery with late delivery clause @ 1% per week maximum to the extent of 10% of the ordered value for delayed supply,after 10 weeks the purchase order will be cancelled ( The delivery period will be calculated from the date of dispatch of purchase order to the date of receipt of material in the Institute ) . In the case of imported goods, the late delivery clause will be imposed @ 0.5% per week subject to the maximum of 5% of FOB value, after10 weeks cancellation of order may be considered. (The delivery period will be calculated from the date of opening of letter of credit to the date of receipt of material at the Indian Port ). Page 5 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 42. The firm has to submit an undertaking that the equipment is of latest model & version, and has the latest state-of-art technology. The spare parts will remain available for at least next ten years. Software upgradation for next ten years from the installation will be included in the cost. 43. List of installations for the quoted model in India should be provided with the tender. 44. All disputes and questions, if any, arise between the Institute and the bidder out of or in connection with the terms and conditions contained herein or as to the construction of application thereof, or the respective rights and obligations of the parties there under or as to any clause or thing herein contained or by reason of the supply or failure or refusal to supply any material or as to any other matter in any way relating to these presents shall be decided by the Director of the Institute and when the decision would not be accepted by the bidder, then the matter shall be referred to the chairman of the Institute as sole Arbitrator . The chairman of the Institute may appoint any suitable Arbitrator whose decision dully approved by the Chairman of the Institute shall be final and binding upon both parties and subject to adjudication of Lucknow Court. Place for arbitration shall be at Lucknow (U.P.), India. Venue of such arbitration proceedings shall be the Institute. Arbitration and conciliation Act 1996 and rules made there under shall be applied to the proceedings under this clause. 45. A minimum of 95% uptime of equipment is to be maintained during warranty period and also after warranty period during comprehensive maintenance contract for the next five years. 46. CMC : The supplier should provide comprehensive maintenance contract (with spare/consumables /Accessories including laborer charges) inclusive of customs and all taxes for the next 5 years (i.e. years 6 to 10 inclusive). The CMC Rate for the sixth year should not be more than 5% of FOB and escalation in next year CMC should also not be more than 5%. Service Tax on CMC will be treated as inclusive if the firm has not mentioned service tax separately. 47. The price bid will be opened in the presence of authorized representative of technically qualified tenderer within reasonable time. 48. i. The price ranking will be carried out as under: For Foreigen Goods the exchange rate of foreign currency will be the prevailing rate on the last date of submission of Tender . ii. The prices for optional items if not required in Technical Specification will be excluded for ranking purpose . The ranking will be determined as under iii. Total Price (Cost) = Price with all accessories as per technical specifications along with Custom duty, Clearance charges, insurance + Cost of indigenous items if anyCMC Price (with spares & labor charges) for five years after warranty + taxes as applicable currently+ Turnkey (if applicable). 49. Custom Duty and Custom Clearance Charges :- The supplier will get the equipment/consignment cleared from the custom. The Custom Duty and clearance charges shall be paid by the supplier which will be reimbursed to them as actual on production of bill which shall not be more than quoted in the price bid. Freight charges will be borne by the manufacturer/Indian representative. Also the insurance will be paid and arranged by the firm effective from port of shipment to Central Store, RMLIMS, LUCKNOW. Page 6 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 # The Rate of Custom Duty and Custom Clearance charges must be mentioned in the price bid. If Custom Duty and Custom Clearance Charges is not mentioned in the price bid, for the purpose of L-1 calculation . Custom Duty & Clearance & other Charges will be calculated @ of 15% of FOB Value or 12% of CIF/CIP value. However the payment shall be made on actual but not more than this Rate. 50. All the operating and service manuals in duplicate to be provided by the vendor at the time of handing over the machine. 51. The percentage (%) or amount of Indian Agency Commission must be mentioned in all offers of overseas suppliers who are offering through their Indian Agency. Authorization certificate issued by the principal in favor of Indian Agent must be enclosed. 52. If there is any discrepancy in terms between General Terms & Conditions of Tender Document and specification of any equipment, then the details given in General Terms & Conditions of Tender Document will be considered valid and will be binding. Accordingly, the terms of comprehensive maintenance contract will be governed by the General Terms & Conditions of Tender Documents. 53. EMD of unsuccessful bidder shall be returned to them in due course of time. 54. Catalogue, data sheet, complete module and other necessary document shall be provided in original form. In the shape of Duplicate or photocopier form of documents shall not be accepted. 55. In case of imported goods consignment must reach Indian port within currency of L/C. 56. No financial documents of any tenderer will be entertained after opening of financial bid/ technical bid. 57. The supplier will make atleastquarterly visit for maintenance during warranty period. Enclosed 1- Annexure A (Specifications of the Equipment) Enclosed 2- Annexure B (Letter of Submission) Enclosed 3- Annexure C (Format for Price Bid in Indian Currency) Enclosed 4- Annexure D (Format for Price Bid in Foreign Currency) Joint Director (MM) for Director Dr. Ram Manohar Lohia Institute of Medical Sciences Vibhooti Khand, Gomti Nagar, Lucknow. Page 7 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Department of Emergency Medicine DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions Portable USG (Fast Screening) DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR PORTABLE USG (FAST SCREENING) A state of art fully digital, compact portable trolley mounted Color Doppler Ultrasound machine is required with following technical features 1. Unit should be able to give very high image quality with advance technologies like compound imaging for better cardiac contrast resolution, tissue differentiation and edge detection, equivalent to high end cart based systems. Please specify the technology. 2. System should be able to support speckle reduction imaging for better tissue differentiation and edge enhancement please specify the technology. 3. The system shall have the ability to enhance tissue margins and improve contrast resolution by reducing artifacts and improving visualization of texture patterns & needle tip within the image, please specify the technology. It should be available in all probes. 4. Enhanced needle visualization in all probes 5. System should have both online (Read) as well as offline(Write) zoom facility 6. Imaging modes of Real time 2D, M mode ,B mode , spectral Doppler , Colour Doppler, Pulsed wave Doppler, Continuous wave Doppler, Power Doppler ,anatomical M mode with 2 lines must be available. 7. Auto clarity tools and auto optimization ( image ,tissue ,spectral ,color) 8. Simultaneous duplex/triplex imaging and simultaneous B/CF mode display 9. Calculation / analysis / measurement package to include emergency medicine ,vascular ,cardiac ,abdominal parameter 10. Continuous depth and zoom adjustment 11. Compound imaging , panoramic, harmonic ,speckle reduction imaging ,trapezoidal view 12. Broad band multi frequency probe technology 13. Capability for post processing of images 14. System must have fast start- up in less than 60 seconds from off condition, for use in critical and emergency situations. 15. System should support transducer technologies like phased array, convex, linear, TEE etc. for both adult and pediatric pts. 16. Cine memory on all modes. 17. The system shall process a dynamic range that is at least 165db. The system must display at a maximum depth of 35 cm. 18. The system must have a dedicated cardiac calculation packages with PISA, TDI calculation packages, vascular calculations package. Full array of measurement and calculation package for emergency care. 19. The unit must be compact, portable and lightweight,. 20. Unit must be sturdy to withstand user site handling damages. 21. Flat LCD/ TFT monitor of at least 15 inches or more with flicker free image. 22. Alphanumeric soft keys keyboard with easy access scans controls, facility to sanitize the system keyboard to avoid cross contamination. 23. The system must have the ability to function by AC/DC or battery power with the same degree of functionality, the battery life (run time) shall be at least one hour or more, this need to be demonstrated. 24. The system must have archive capability for storage and retrieval of images and clips data with integrated CD/DVD writer.(more is preferred) 25. Data transfer facility should be available as standard, to transfer images etc. easily into another system/computer etc. 26. The system shall support the all DICOM functionality, Storage, Print, and Work List, also ready to connect to PACS./HIS . Colored printer should directly be connected to USG machine. 27. The manufacture shall provide a loaner system / standby in case of failure of system. 28. The equipment should be supplied with trolley of the same manufacturer. 29. System configured application specific educational video tutorials should be provided as standard with the system. 30. System should both be European CE and US FDA certified. 31. System should be supplied with facility of electronic and active switching device for minimum two transducers and two parking port in trolley 32. Facility for training and education of residents Page 1 of 2 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 33. Easy tilting forward and backward to view in all angles. 34. Multiple preloaded application presets for emergency medicine Transducers to be supplied as standard 1. 2. 3. 4. 5-18 MHz multi-frequency, broadband linear array transducer,. Higher frequency will be preferred. 1-6 MHz multi-frequency broadband curved array transducer 1-4 MHz multi-frequency, broadband phased array transducer –trans cranial Doppler 4-13 MHz multi-frequency, broadband linear transducer for DVT and vascular probe 5. 4-8 MHz multi-frequency broadband phased array transducer for Pediatric Cardiology (approximate foot print of 10mm and depth of 14 cm). 6. Intima media thickness and biopsy guided capability 7. Prices of adult and pediatric TEE should be coated separate ESSENTIAL REQUIREMENT: The firm must, attach list of installations, and also provide performance certificates in last 5 years from major hospital of repute . Page 2 of 2 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions MRI Compatible Infusion Pump DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR MRI COMPATIBLE INFUSION PUMPS 1. Microprocessor-controlled motor capable of accurate propulsion 2. Should accept syringes of varying volume. 3. Should be easy to use and user friendly 4. Should have automatic detection of syringe size. 5. For 50 ml syringe flow rate should be from 0.1 ml/h to 1000 ml/hr. with up-to 0.1 ml/hr increments 6. Should be Bolus dose programmable with infused volume displayed. 7. Should have large ,bright display Panel with Provision for display of flow rate, battery indicator, Drug name & total infused volume all at a time. 8. Should have Drug Library of 30 drugs or more 9. Digital display of Occlusion pressure 10. Should have Occlusion pressure pre alarm ,KVO , 11. syringe empty and volume infused alarm 12. Should have PM line disconnection alarm 13. Should have volume limit pre alarm 14. Should have mains disconnection alarm 15. ,battery charge low alarm internal malfunction alarm 16. Should have sufficient battery backup even for transportation of pts. .(More is preferable) 17. Should display remaining battery life in Hrs. & minutes on operating flow rate 18. Should have Universal mounting accessary on both vertical & horizontal stand. 19. Should have facility of auto dose calculation 20. Flow rate accuracy should be +/- 1-2 % 21. Should have provision for MRI Compatibility. 22. USFDA and European CE approved 23. The firm must, attach list of installations, and also provide performance certificates in last 5 years from major hospital of repute Page 1 of 1 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions Incubator DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR INCUBATOR Heavy duty construction and hardware with glass window. High grade glass wool with sufficient insulation to avoid heat losses. Shelves --- Inner chamber has ribs for placing the shelves at convenient levels. Supplied with at least 2 Nos. of removable shelves. Heating Element is made of high quality material and suitable for uniform temperature all over the place. Temperature. Range 30 to 110 C±5°C with digital display and alarm for set temp. Over temperature indicator (visual/audible) Temperature set point lock Should have digital LED display with ON/OFF key , increase /decrease key ,USB port Fail safe feature remembers the operational mode in the event of power failure Ventilation- Air ventilator should be provided Size:- 300x300x300mm approx.. USFDA and European CE certified Must submit user list and performance report within last 5 years from major hospitals Page 1 of 1 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions Transport Monitor DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR TRANSPORT MONITOR 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 12. Should be suitable for adult, pediatric neonatal patients monitoring. Should have minimum 4 channels of waveforms with minimum 8‟‟ display Battery backup for minimum three hours should be provided as standard. Should have automatic graphic and tabular trending of all monitored parameters as standard Should have event recall with waveforms, graphical and tabular trends, alarm logs. Should have minimum support of ECG, NIBP, IBP , SpO2, Respiration & Temperature(core and skin). And invasive facility Should have Arrhythmia detection Should have excellent cable management with as minimum as possible cables at monitor & patient end for maximum comfort to patient as well as user. System should be US FDA and Europian CE approved SpO2: Should display digital value and Plethysmograph NIBP : Should display Systolic, diastolic, mean pressure in large , easy to read display It should have manual/ stat mode or automatic mode with adjustable time intervals from 2 – 240 minutes and adjustable alarm limits Scope of supply must include: 13. ECG Cable – 4 no SpO2 sensor for Adult and Pediatric – 1 no. each Rectal / Esophegal temperature probe – 1 no NIBP Hose – 2 no Adult & Paediatric Cuff – 5 each System should be able to facilitate web browsing facility to review each networked monitor‟s data. 14. The firm must, attach list of installations, and also provide performance certificates major hospital of repute Page 1 of 1 in last 5 years from DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions Anesthesia Work Stations DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR ANESTHESIA WORK STATIONS TECHNICAL SPECIFICATIONS FOR ANESTHESIA WORKSTATION 1. 2. 3. 4. Gas Management: Three Gas system : Oxygen , Air, Nitrous Oxide Oxygen cylinder yoke and Nitrous Oxide cylinder Yoke Pipeline inlet for Oxygen, Air, Nitrous Oxide Oxygen Concentration: 25% to 100% Electronic Gas Mixing measurement and display for accurate gas flows and mixing. Pneumatic Oxygen Backup flowmeter Auxillary Oxygen Flowmeter Oxygen Flush between 35 lpm -70 lpm Will have two drawers for storage Will have an additional optional receptacle for accepting/ integrating Anesthesia Gas monitoring module. Should have a decision support tool for optimizing FGF. Colour coded high pressure tubings 5 meter long for oxygen, nitrous oxide and air with suitable pipeline connectors. Hypoxic guard to ensure minimum 25% oxygen across all O2-N2O mixtures. Oxygen failure warning device. All alarms to be audio as well as visual. Should have 3 gas back up mechanical flow control in case of failure of electronics Vaporizers: Vaporizer must be isolated from the gas flow in the off position and prevent the simultaneous activation of more than one vaporizer. Vaporizer shall require no tools to mount. Vaporizer shall mount to a Selectatec® manifold which allows easy exchange between agents. Supplier must offer total vaporizer manufacturing capability- Sevoflurane, and Isoflurane. Isoflurane and Sevoflurane vaporizers to be standard accessories. Other vaporizers to be optional and price for each to be quoted. Back bar to accept two selectatec vaporizers Breathing System: Breathing system shall be fully autoclavable to134° C and natural latex free. It should be compact. Total circuit volume shall not exceed 2.7 L, including Absorber volume. Breathing system shall have integrated Volume sensing and shall be of a type that does not require daily maintenance. Ventilator bellows shall be integrally mounted to the breathing system. Should have Ascending Bellows design. Bag to vent switch shall be bi-stable and automatically begins mechanical ventilation in the ventilator position. Adjustable pressure limiting valve shall be flow and pressure compensated. Machine shall provide circle mode breathing circuits. Components coming in contact with patient gas shall be disposable or autoclavable. FIO2 monitoring should be available. Common Gas outlet should be standard supply for connecting open circuit. AGSS ready to be connected to hospital installed active system Ventilation The workstation should have integrated Anesthesia Ventilator system. Ventilator based on flow valve technology with ICU features and modes of ventilation . Visible bellows for visual indication of leaks in the systems . Ventilator shall have Volume Control and Pressure Controlled modes. Page 1 of 3 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Dual Mode – PCV, VCV and PS needed for difficult lung ventilation, Obese patients ,laproscopy , beating heart , and neonatal . Ventilator shall have a tidal volume compensation capability to adjust for losses due to compression, compliance and leaks; and compensation for fresh gas flow. The workstation should be capable of delivery of low flow and minimal flow anesthesia. Ventilator shall be capable of atleast 120 L/min peak flow to facilitate rapid movement through physiologic “dead space” in the Pressure Control mode SIMV and Pressure Support Ventilation with Apnea Back Up Ventilation should be offered It should have a cardiac bypass mode.during cardiac bypass procedure to stop the system from alarming , and turns off automatically , when the ventilator is turned back on . Compliance Measurement and Trending ( Preferable ):Measures and dispalys the patient‟s compliance to offer an view of the patient‟s lung condition. Vital Capacity & Cycling procedures ( Preferable ) : to automate the procedures for optimal Peep setting to recruit the lungs . Tidal Volume: 20ml to 1500ml in VCV .TV= min 5 ml in PCV mode. Rate : 4 to 100bpm Electronic Peep : Off, 4 to 30cms H2O Settable I:E ratios, Pause, Trigger ( 0.2-10 L/min ), Insp Pressure from 5 up to 50cms H2O Ventilator shall be capable of 120 L/min peak flow . Ventilator shall have a tidal volume compensation. Operates on a breath-by-breath basis and does not require special calibration. Inspiratory pressure (Pinspired) 5 - 60 cm H2O Pressure limit (Plimit) 12 to 100 cm H2O Machine should have atleast 60 mins battery backup Shall have integrated LED light strip that provides bi-level work surface illumination. Handle on side for easy positioning. Machine should have mounting capability of one O2 and one N2O pin-indexed cylinder. 5. Display: Around 12-15 “ Color TFT Display with High visibility and highly visible alarm light mounted on the Anesthesia Workstation Monitor should be Modular and flexible Colour touch screen display Up to 8 waveforms / 4 digit fields, 7 optimized user modes , Standard Adult, Pediatric & Neonate mode with OxyCRG Easy to set with Comp wheel , Split screen facility to view Mini trend for 5 -30 mins. Trend up to 72 hours of graphic and numerical data Should have an individual Battery backup, minimum of 2 hrs . ECG and IBP analog output. Should have arrhythmia and ST segment Analysis with ST Trend Monitor should have Simultaneous Monitoring facility for 2xIBP & 2xTemp for all monitors Basic Patient side module for Measuring Parameters like 5 lead ECG, NIBP, SPO2, RESP, 2xIBP, 2xTemp, EtCo2( side stream), Anaesthesia Gas monitoring, Level of Depth of Anaesthesia monitoring and NM monitoring Accessories - Standard use for ECG(2 in no.), SpO2 probes (2 each for adult &pediatric), NIBP(2 cuffs each for adult and pediatric& 1 for neonate), Temperature probes( 1 for core and 1 for skin), IBP cables (2 in no with 10 pressure transducers and their one holder), EtCO2- 5 filter assemblies and 10 tubings, for anaesthesia gas monitoring, depth of anaesthesia monitoring(with 25 disposable leads),NM Monitoring cables Recorder option for printing the up to 4 waveforms and alphanumeric data , and trends etc . Page 2 of 3 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 6. 7. 8. 9. Power: Will work on electric mains Anaesthesia workstation should have an individual battery backup of up to 45mins on fully charged battery . Should have integrated lighting for vaporizers and working table(optional) Braking Mechanism Front caster wheel should have a central braking mechanism Following upgrades should be offered as options – (Quote unit prices in price bid) 1. EtCO2 monitoring should be possible 2. EEG – minimum 4 channels with display of spectra 3. Cardiac Output module for measuring the cardiac output using the thermo-dilution technique with four Invasive pressure channels. 4. Module for monitoring Cardiac Output 5. Facility for monitoring transcutaneous O2 /CO2 and ScVO2 monitoring with Calibration kit 6. Facility for EtCO2 with dedicated accessories for Adult, Paediatric & Neonates (25 each) 7. Facility of automatic electronic charting solution with data archival facility for patient monitor and ventilator data. It should be single centralised server based for multiple beds upgrade. 1. Anaesthesia workstation and monitor should. USFDA and EUROPIAN CE 2. Must submit user list and performance report within last 5 years from major Government hospitals. Page 3 of 3 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions Cautery Machine DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR CAUTERY MACHINE The system should have Monopolar Cut & Coagulation, Bipolar and Vessel Fusion technology all integrated in one system. The input operating range of the system should be wide The equipment should adjust the power to get the desired surgical effect on the tissue. Monopolar outputs should have cutting modes. It should have Coag Modes . The Monopolar Mode should also have Haemostasis mode. The system should device with three button pencil with facility to control the power from the sterile zone. The system should gave Graf facility to show the deliver power and recall facility to recall the last setting used by user. The system should be compatible with argon machine & smoke evacuation system. Its should have Bi-Polar modes. The Systems should have Bipolar Current Monitor. The System should have Auto Bipolar start and stops where users can set the Auto start delay time and Auto Stop impedances range. The System should have LCD Backlight adjustment for good visibility in operating room. Vessel Fusion system should be able to seal artery, veins along with tissue bundle up to 7mm, and fused vessels should be able to withstand raised systolic blood pressure. The 7mm Vessel Fusion technology should be US FDA approved. It should have patient plate monitoring facility and should give audiovisual alarm and deactivate output if contact between patient and patient plate is not proper to eliminate the risk of patient burns. The system should be able to record last events. The system should have front panel calibration for fast and easy maintenance. On Screen review of error codes and diagnostics. The Equipment Should be US FDA/CE approved Installation should be made by the Trained Engineers. Monopolar footswitch-1 no. Vessel sealing footswitch-1 no. Hand switching pencil- 50 nos. Contact quality monitoring return electrode- 100 nos. Bayonet Bipolar forceps-1 no. Forceps cord-2 nos. Universal adaptor- 1 no. Open & laparoscopic 5mm seal and cut instrument with hand switch activation capability should provide with the system-20 nos each IndianOriginal trolley Reusable Open surgery Vessel seal instrument with Cord-2 nos All Accessories make of same Company. Page 1 of 1 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions General Instruments Set DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR GENERAL INSTRUMENTS SET SPECIFICATIONS : All instruments should be US FDA / EUROPEAN CE Approved 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. S. S. TRAY BIG with Lid 450mm x 350mm x 80mm K. DISH 1000ml K. DISH 500ml S. S. BOWL 1000 ml S. S. BOWL 500 ml S. S. BOWL 100ml SPONGE HOLDER 10” TOWEL CLIPS 5” BP HANDLE 3 BP HANDLE 4 BP HANDLE 7 ADSON TOOTHED ADSON NON-TOOTHED DISSECTING FORCEPS TOOTHED 6”‟ DISSECTING FORCEPS NON-TOOTH 6‟ DISSECTING FORCEPS TOOTHED 8” DISSECTING FORCEPS NON-TOTTH 8‟ DISSECTING FORCEPS NON-TOOTHED FINE 8” DISSECTING FORCEPS DEBEKEY DISSECTING SCISSORS CVD 7” METZ DISSECTING SCISSORS CVD 8” METZ DISSECTING SCISSORS CVD 6” MAYO SUTURE CUTTING SCISSRS STR 7” METZ SUTURE CUTTING SCISSRS STR 7” MAYO MOSQUITO CVD 12ccm MOSQUITO STR 12cm ARTERY Forceps STR 6” ARTERY Forceps CVD 6” ARTERY Forceps CVD 8” ARTERY Forceps STR 8” ALLIS Forceps 6” ALLIS Forceps 8” KOCHER CVD 8” KOCHER STR 8” BABCOCK Forceps 6‟ BABCOCK Forceps 8” RIGHT ANGLE 6” RIGHT ANGLE 8” FINE TIP RIGHT ANGLE 10” FINE TIP NEEDLE HOLDER 6” NEEDLE HOLDER 7” FINE TIP NEEDLE HOLDER 8” HEAVY INTESTINAL CLAMP CVD 10” INTESTINAL CLAMP STR 10” POOL SUCTION TIP L. B. RETRACTOR SMALL ½” X 2cms L. B. RETRACTOR 1” X 2cms L. B. RETRACTOR 2” X 2cms L. B. RETRACTOR 3” X 2cms MORRIES RETRACTOR DEVER‟SRETRACTOR (SETOF 6) Page 1 of 2 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Battery Operated Drill & Saw System Tender specifications Battery Power System should be versatile functions and should used in all applications require in large bones and small bones. The two trigger drill hand piece should have the feature of Drilling, Reaming & Oscillation mode. The cannulation of the drill hand piece should be more than 4.5mm. The modular Drill Hand piece should have adaptability to have variation in Speed and torque with different attachment to have different functions in drilling and reaming. The speed torque ratio should be at least of three variations like 1:1, 3:1 and 5:1. The drilling speed should be more than 900 RPM and torque should be available up to 11 Nm. Should have quick coupling drilling attachments for AO small , Wire Driver, Pin Driver and Jacobs chuck. Should have quick coupling Reaming attachments for AO large and Jacobs Chuck . Bur Attachment compatible Drill Hand piece for removal of cement in revision surgery for high speed application maximum speed 30,000 RPM Short, medium and long Bur guards and Bur(10 Nos) to be supplied with Bur attachment for cement removal The system should have dedicated oscillating saw hand piece. The speed of dedicated Oscillating Saw should be more tha 10,000 CPM. The oscillating saw hand piece should have rotating head at 4 intervals in 90deg each. The system should have Arthroplasty blades(10 Nos) and special trauma blades for sawing(10 Nos). Four station Battery charger. Should have NiMH battery (4 Nos). Sterilization Case for the complete system The system should be CE/US FDA Approved. ITEMS QUOTED SHOULD BE OF ONE MAKE Page 2 of 2 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions Trauma Set DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR TRAUMA SET SPECIFICATIONS : All instruments should be US FDA / EUROPEAN CE Approved BASIC TRAUMATOLOGY & OT INSTRUMENT SETS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Small Fragment Instrument Set Drill bit Ø 2,0 mm Drill bit Ø 2,5 mm Drill bit Ø 3,5 Tap 3,5 mm Cortex Tap 4,0 mm Cancellous Screwdriver 2,5 mm Hex Screw holding sleeve Screwdriver Shaft 2,5 mm Hex T-Handle, small Double Drill Sleeve 2,5 mm / 3,5mm Insert Drill Sleeve 2,5 mm/ 3,5 mm Drill Guide Neutral & Load 3,5 mm Universal Drill Guide 3,5 mm / 2,5 mm Perisoteal Elevator 6mm, curved 60 mm Depth Gauge Bending Iron for K-Wires 1,25 mm up to 2.5 mm Bending Template 3,5 mm 5 holes Bending Template 3,5 mm 7 holes Bending Template 3,5 mm 9 holes Bending Iron 2,7 mm/ 3,5 mm right Bending Iron 2,7 mm/ 3,5 mm left Hohmann Retractor 8mm Hohmann Retractor 15 mm 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 24 Sharp Hook 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Large Fragment Instrument Set Drill bit Ø 3,2 mm x 145 / 120 mm, three-fluted Drill bit Ø 4,5 mm x 145 / 120 mm, three-fluted Tap for 4,5 mm Screws Tap for 6,5 mm Cancellous Screws Countersink w. T-Handle for 4,5 mm and 6,5 mm Screws Large Screwdriver 3,5 mm Hex Large Screwdriver Shaft 3,5 mm Hex Large Screw Holding Sleeve for 4,5 mm and 6,5 mm Screws Double Drill Sleeve 4,5 mm / 3,2 mm Double Drill Sleeve 6,5 mm / 3,2 mm Insert Drill Sleeve 4,5 mm / 3,2mm Drill Guide neutral & load Universal Drill Sleeve 3,2 mm / 4,5 mm Tension Device Depth Gauge 110 mm for 4,5 mm and 6,5 mm Screws Bending Iron for 4,5 mm plates for use with 04.20110.001 Bending Template, 7 holes Bending Template, 9 holes Bending Template, 12 holes Sharp Hook 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Page 1 of 5 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 21 T Handle with QC 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Mini Fragment Instrument Set Tap 1,5 mm Tap 2,0 mm Tap 2,7 mm Countersink 2,7 mm / 4,0 mm Screwdriver Shaft 1,5 mm Hex Screwdriver 1,5 mm Hex Mini Quick Coupling Handle Quick Coupling Handle Double Drill Sleeve 1,5 mm / 1,1 mm Double Drill Sleeve 2,0 mm / 1,5 mm Double Drill Sleeve 2,7 mm / 2,0 mm Triple Drill Sleeve 2,0 mm Periosteal Elevator 3mm, straight Hohmann Retractor 6 mm Hohmann Retractor 8mm Hohmann Retractor 15 mm 38mm Depth Gauge with cap Bending Iron for 1,5 mm / 2,0 mm Plates Bending Pliers for 1,5mm/ 2,0mm Plates Bending Iron for K-Wires 0,8 mm - 1,25 mm Bending Iron for K-Wires 1,2 mm - 2,5 mm Sharp Hook 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 23 Pick Up Forceps 1,5 mm - 2,7 mm Screws 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Broken / Damaged Screw Instrument Set Screw holding forceps, 205 mm Mini Lexer gouge, 4 mm Mini Lexer gouge, 6 mm Mini Lexer gouge, 10 mm Conical extraction screw for 1,5/2,0 mm screws Conical extraction screw for 2,7/3,5/4,0 mm screws Conical extraction screw for 4,5/5,0/6,5/7,0 mm screws Sharp hook, 155 mm Hollow reamer, complete, for 1,5 mm screws Hollow reamer, complete, for 2,0 mm screws Hollow reamer, complete, for 2,7 mm screws Hollow reamer, complete, for 3,5/4,0 mm screws Hollow reamer, complete, for 4,5 mm screws Hollow reamer, complete, for 5,0/6,5/7,0 mm screws Hollow reamers tube 1,5 mm screws Hollow reamers tube 2,0 mm screws Hollow reamers tube 2,7 mm screws Hollow reamers tube 3,5/4,0 mm screws Hollow reamers tube 4,5 mm screws Hollow reamers tube 5,0/6,5/7,0 mm screws Extraction bolt f. 1,5 mm screws Extraction bolt f. 2,0 mm screws Extraction bolt f. 2,7mm screws Extraction bolt f. 3,5/4,0 mm screws 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Page 2 of 5 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 25 Extraction bolt f. 4,5 mm screws 1 Bone Holding Forcep Set 1 2 3 4 5 6 7 8 9 Self Centring Bone Holding Fcp 15cm Self Centring Bone Holding Fcp 19cm Self Centring Bone Holding Fcp 24cm Self Centring Bone Holding Fcp 26cm Self Centring Bone Holding Fcp 28cm Reduction Forceps, with points, , 135 mm Reduction Forceps, with points, broad, 170 mm Reduction forceps with points, 200 mm Reduction forceps, serrated, 160 mm 2 2 2 2 2 2 2 2 2 10 Reduction forceps, serrated, 240 mm 2 Wire Instrument Set 1 2 3 4 5 6 7 Triple Drill Sleeve 2,0 mm Forceps for Cerclage Wires Flat Nose Parallel Pliers, 185 mm Wire Passer 45 mm Wire Passer 70 mm A O Wire Tightener, 230 mm Bending Iron for K-Wires 1,2 mm - 2,5 mm 1 1 1 1 1 2 2 8 Wire Cutter 220 mm for Wires up to Ø 2.5 mm General Instrument Sets for Orthopaedics 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Mini-Hohmann Bone Lever 6mm 16cm Mini-Hohmann Bone Lever 8mm 22cm Lane Bone Lever 25.5cm Bristow Bone Lever 23cm Stille Bone Chisel 10mm 20cm Stille Bone Chisel 15mm 20cm Stille Bone Chisel 20mm 20cm Stille Bone Osteotome 10mm STR 20cm Stille Bone Osteotome 15mm STR 20cm Stille Bone Osteotome 20mm STR 20cm Perioseteum Elevator 6mm Straight 18.5cm Farabeuf Raspatory STR 15cm McDonald Bone Elevator 19cm Liston Bone Cutting Fcp STR 22cm Liston Bone Cutting Fcp CVD 22cm Stille-Liston Bone Cutting Fcp STR 27cm D/A Beyer Bone Rongeur 18cm D/A Rottgen-Ruskin Bone Rongeur 24cm D/A Weitlaner Retractor 13cm Sharp ( 3x4TH ) Weitlaner Retractor 16cm Sharp ( 3x4TH ) Adson Retractor 26cm Blunt Kocher-Langenbeck Retractor 21.5cm ( 35x8mm) Kocher-Langenbeck Retractor 21.5cm ( 55x11mm) Kocher-Langenbeck Retractor 21.5cm ( 80x16mm) Mayo-Collin Ret4ractor 15cm Set of 2 Volkmann Retractor Blunt 22cm (3 Prong) Hollow Handle Volkmann Bone Curettes 16cm Oval/Round D/E Volkman Bone Hook, (Choice of Sharp / Blunt) Kleinert-Kutz Wound Retractor (5mm) 13cm 2 2 1 1 2 2 2 2 2 2 2 2 2 1 1 1 2 1 2 3 2 2 2 2 2 2 2 2 2 Page 3 of 5 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 30 31 32 33 Kleinert-Kutz Wound Retractor (7mm) 13cm Finger Ring Cutter Saw Blade 16cm Hammer SS Handle 500gm Hammer SS Handle 270-320 gm 34 T-Handle Jacobs Chuck 2 2 1 1 1 Bending Press 1 Bending Press 1 Carpel Tunnel Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Tissue Fcp ( 1x2 TH ) 16cm Adson Tissue Fcp ( 1x2 TH ) 12cm Adson-Dressing Fcp 12cm Scalpel Handle no. 3 Scalpel Handle no. 7 Fergusson Suction Tube 17cm 12Fig 4mm Fergusson Suction Tube 17cm 14Fig 4 3/4mm Forester Sponge Holding Fcp Smooth STR 20cm Backhaus Towel Fcp 13cm Halstead Mosquito A/Fcp CVD ( Serr ) 12.5cm Rochester Pean A/Fcp CVD (Serr) 16cm Allis Tissue Fcp 5x6 TH 15cm Derf Needle Holder T/C 12cm De-Bakey Needle Holder T/C 18cm Metzenbaum-Fine Scissor CVD SH/BL 14.5cm T/C Metzenbaum-Fine Scissor STR BL/BL T/C 18cm Mayo-Noble Scissor STR 17cm Cushing Dressing Fcp STR 17.5cm Watson-Cheyne Probe 13cm Watson-Cheyne Probe 18cm Senn-Muller Retractor Sharp 16cm Langenbeck Retractor 21cm (35x7mm) Gillies Nerve Hook ( Fig. 1 ) 18cm Alm Retractor 10cm (4x4) Blunt 1 1 1 1 1 1 1 2 6 2 2 2 1 1 1 1 1 1 1 1 2 2 2 1 25 Weitlaner Retractor 13cm Blunt ( 3x4TH ) 1 General Spine Instruments 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Kerrison Disc rongeur 1mm, 200mm 8" 130deg Up Kerrison Disc rongeur 2mm, 200mm 8" 130 deg Up Kerrison Disc rongeur 3mm, 200mm 8" 130 deg Up Kerrison Disc rongeur 4mm, 200mm 8" 130deg Up Kerrison Disc rongeur 5mm, 200mm 8" 130deg Up Kerrison Punches with Ejector, 130 Degree Down, 2mm, 180mm Kerrison Punches with Ejector, 130 Degree Down, 3mm, 180mm reg Penfield dissector 17.5cm 7" Penfield dissector 19.5cm 7 3/4" Penfield dissector 19.5cm 7 3/4" Davis dissector 24.5cm 9 3/4" Volkmann Bone Curette 20 8" Volkmann Bone Curette 20 8" 000 Volkmann Bone Curette 20 8" 00 Volkmann Bone Curette 20 8" 0 Volkmann Bone Curette 20 8" 1 Volkmann Bone Curette 20 8" 0 Volkmann Bone Curette 20 8" 00 Page 4 of 5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Volkmann Bone Curette 20 8" 000 Stille Bone Rongeur 23cm D/A Stille-Luer Bone Rongeur STR 27cm D/A Echlin Bone Rongeur 3mm 23cm D/A Mayfield Bone Rongeur 17cm D/A Ferris-Smith Rongeur 2 x 10mm 18cm Shaft Straight Ferris-Smith Rongeur 3 x 10mm 18cm Shaft Straight Ferris-Smith Rongeur 4 x 10mm 18cm Shaft Straight Ferris-Smith Rongeur 2 x 10mm 18cm Shaft upward Ferris-Smith Rongeur 3 x 10mm 18cm Shaft Up ward Ferris-Smith Rongeur 4 x 10mm 18cm Shaft Up ard Ferris-Smith Rongeur 2 x 10mm 18cm Shaft Down ward Ferris-Smith Rongeur 3 x 10mm 18cm Shaft Down ward Ferris-Smith Rongeur 4 x 10mm 18cm Shaft Down ward Weitlaner Retractor 10.5cm Sharp ( 2x3TH ) Weitlaner Retractor 16cm Sharp ( 3x4TH ) Anderson-Adson Retractor 20cm Blunt Adson Retractor 26cm Blunt 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 37 Beckmann-Adson Retractor 31cm ( 44mm ) blunt 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Extra Kerrison Punch Set Kerrison Disc rongeur 1mm, 180mm 7" 40deg Up Kerrison Disc rongeur 2mm, 180mm 7" 40 deg Up Kerrison Disc rongeur 3mm, 180mm 7" 40 deg Up Kerrison Disc rongeur 4mm, 180mm 7" 40 deg Up Kerrison Disc rongeur 5mm, 180mm 7" 40 deg Up Kerrison Disc rongeur 1mm, 180mm 7" 40deg down Kerrison Disc rongeur 2mm, 180mm 7" 40 deg down Kerrison Disc rongeur 3mm, 180mm 7" 40 deg down Kerrison Disc rongeur 4mm, 180mm 7" 40 deg down Kerrison Disc rongeur 5mm, 180mm 7" 40 deg down Kerrison Disc rongeur 1mm, 180mm 7" 40deg Up Kerrison Disc rongeur 2mm, 180mm 7" 90 deg Up Kerrison Disc rongeur 3mm, 180mm 7" 90 deg Up Kerrison Disc rongeur 4mm, 180mm 7" 90 deg Up Kerrison Disc rongeur 5mm, 180mm 7" 90 deg Up Kerrison Disc rongeur 1mm, 180mm 7" 90 deg down Kerrison Disc rongeur 2mm, 180mm 7" 90 deg down Kerrison Disc rongeur 3mm, 180mm 7" 90 deg down Kerrison Disc rongeur 4mm, 180mm 7" 90 deg down 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 20 Kerrison Disc rongeur 5mm, 180mm 7" 90 deg down 1 2 3 4 Dressing Fcp STR 15cm Crile Rankin A/F STR 15cm Metzenbaum-Fine Scissor Curved 18cm Metzenbaum-Fine Scissor STR 18cm 10 10 5 5 5 Mayo-Hegar Needle Holder 5 Dressing Set - ( Suture removal ) Page 5 of 5 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions Micro Trauma Set DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR MICRO TRAUMA SET Micro trauma set 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Halsey Needle Holder 13cm Serr Kilner ( Ragnell ) Scissor 12cm Semken Tissue Fcp ( 1x2 TH ) 12cm Semken Dressing Fcp 12cm Alm Retractor 7cm Sharp Iris Scissor Standard STR 11.5cm Iris Scissor Standard CVD 11.5cm Fergusson Suction Tube 17cm 6Fig 2mm Fergusson Suction Tube 17cm 7Fig 2 1/2mm Fergusson Suction Tube 17cm 8Fig 2 2/3mm Adson Tissue Fcp ( 1x2 TH ) 12cm Adson-Dressing Fcp 12cm Castroviejo Needle Holder Smooth T/C 18cm STR Serr W/Ratchet Vascular set Operating Scissor STR Fig. 2 14cm SH/BL Mayo Scissor STR 17cm Mayo Scissor CVD 17cm Metzenbaum Scissor CVD SH/BL 18cm Metzenbaum Scissor CVD BL/BL 20cm Metzenbaum Scissor CVD SH/BL 23cm Universal Wire Cutting Scissor 12cm Universal Wire Cutting Scissor T/C 12cm Halstead Mosquito A/Fcp CVD ( Serr ) 12cm Crile A/Fcp CVD 14cm Coller-Crile A/Fcp CVD (Serr) 16cm Rochester Pean A/Fcp CVD (Serr) 16cm Oschsner-Kocher A/Fcp STR (1x2 TH) 16cm Oschsner-Kocher A/Fcp STR (1x2 TH) 18cm Backhaus Towel Fcp 13cm Scalpel Handle no. 3 Scalpel Handle no. 7 Scalpel Handle no. 3L Forester Sponge Holding Fcp Serrated STR 25cm Mayo-Hegar Needle Holder 16cm Mayo-Hegar Needle Holder T/C 16cm Mayo-Hegar Needle Holder 18cm Mayo-Hegar Needle Holder T/C 18cm Mayo-Hegar Needle Holder 20cm Mayo-Hegar Needle Holder T/C 20cm Dressing Fcp STR 14.5cm Dressing Fcp STR 20cm Tissue Fcp ( 1x2 TH ) 14.5cm Tissue Fcp ( 1x2 TH ) 20cm Adson Tissue Fcp ( 1x2 TH ) 12cm Allis Tissue Fcp 5x6 TH 15cm Allis Tissue Fcp 5x6 TH 19cm Allis-Adair Intestinal Fcp 15cm Babcock Tissue Fcp 16cm BABY-MIXTER Ligature Forceps 18cm Page 1 of 2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 1 1 1 2 1 1 1 1 6 6 6 6 6 2 8 4 2 2 6 4 4 4 4 2 2 2 2 2 1 2 6 2 2 2 4 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 Gemini Dissecting Fcp 16cm Gemini Dissecting Fcp 20cm Poole Suction Tube ( 10mm ) 22cm STR Poole Suction Tube ( 8mm ) 22cm CVD Yankauer Suction Tube 27cm Senn-Muller Retractor Sharp 16cm Parker-Langenbeck Retractor ( U.S. Army ) 21cm Set of 2 Roux Retractor Set of 3 Green Retractor 22cm Cushing Vein Retractor 12mm 24cm Richardson Retractor 26cm ( 28x20mm ) S/E Richardson Retractor 26cm ( 36x28mm ) S/E Richardson Retractor 26cm ( 44x38mm ) S/E Deaver Retractor 30cm ( 25mm ) Deaver Retractor 30cm ( 38mm ) Deaver Retractor 30cm ( 50mm ) Deaver Retractor 30cm ( 75mm ) Abdominal Spatula Malleable 33cm ( 25mm ) Abdominal Spatula Malleable 33cm ( 40mm ) Abdominal Spatula Malleable 33cm ( 50mm ) Volkmann Retractor Blunt 21.5cm (4 Prong) Weitlaner Retractor 16cm Sharp ( 3x4TH ) Adson Haemostatic Fcp (1x2 TH) STR 18cm Adson Haemostatic Fcp (1x2 TH) CVD 18cm Crafoord Haemostatic Fcp 18cm SPECIFICATIONS : All instruments should be US FDA / EUROPEAN CE Approved Page 2 of 2 4 2 1 1 2 4 1 1 1 2 2 2 2 2 1 1 2 1 1 1 2 2 2 4 4 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions Arthroscopy Set DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR ARTHROSCOPY SET High Definition Camera System for Arthroscopic Surgeries Full High Definition Digital Camera The system should have following features: It should be a Three Chip high definition camera with digital video of 1920x1080resolution camera head and console The system should have Digital /Optical Zoom to enhance the quality of Image size regardless of the telescope used. Button controls on camera Head to control vital functions of camera, like White Balance, Brightness etc. Video Outputs: Minimum : DVI, S-Video HDSDI The Camera should preferably have Signal to Noise ratio range of 60-70dB. The Camera Head should have a focusing coupler for even focus control. Should offer both NTSC and PAL Video Formats. The Unit should be compatible for recording of stills and videos using Universal Serial Bus. The system should be Menu driven, thus allowing the surgeon to program the camera head functions as per the surgical needs & requirement. Technical Specifications: Image System: 1/3” CCD Pixels AGC: Signal-to-noise ratio Video output: High Definition Medical Grade Monitor 1920 X 1080 pixels per chip Microprocessor controlled 60-70 dB S-Video HD-SDI & DVI (Minimum) The system should have: Hi Definition Colored Monitor 24’’-26” Flat Panel Monitor PAL system compatible. Composite, S-Video and HDSDI , DVI inputs(Minimum) Compact & Lightweight design. Resolution more than 1100 lines Xenon Light Source 300 W Xenon Light Source with 100-240 V Xenon bulb should emit light at temperature of 5700-6000K Minimum bulb life of 500hours. Light intensity adjustable from console. Universal Light cable acceptance on console. Display of Bulb hours elapsed on console Fiber Optic Light Cable Size should be diameter > 3.5mm, length >160 cm Arthroscopes Wide Angle, Direct View Arthroscopes Light Guide insertion on opposite side of the direction of view with a J-lock fixation for cannula. Page 1 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Working Length of Not more than 160mm Optimal centre-to-edge resolution for enhanced picture quality Angle of view: 70º 30º Diameter 4mm Fiber optic light transmission incorporated Standard ocular window for coupling the camera head Scratch resistance sapphire quoted tip lens Advanced Rod lens system for optimum brightness, contrast and definition Arthroscopes should be supplied with compatible cannulas high flow, double valve, fully rotatable with fenestrated tip & conical and blunt tip obturator. Arthroscopic Resection Shaver System The Shaver system should comprise of Controller Console, Shaver Hand-piece, Footpedal. Controller Unit The Controller console should have receptacles for both Shaver hand-piece, Foot Pedal and also other powered instrumentation The console screen should capture all information pertaining to minimum, maximum and set speeds for installed blade type; horizontal bar graph of blade speed relative to range; blade direction; diagnostic information. Should provide control for momentary push switches for increasing and decreasing speed setting. The Console should provide variable rpm ranging between 100rpm to 10,000 rpm as per the blade or burs used. The Motor should offer Forward, Reverse and Oscillation Mode for Resection. Shaver Hand Piece The autoclavable shaver handpiece, which is compact, lightweight and ergonomically designed, with optional hand control. The connecting cable should be autoclavable and replaceable with lenght of approx. 10Ft. The handpiece should be not more than 8 Inches length and 460gms. The handpiece should have suction control lever. The Shaver Handpiece should have safety mechanism of Blade Window Lock to avoid any unintentional tissue damages on pull out. The Shaver hand piece should have push-button motor controls: Forward, Reverse, Oscillate, and Blade and Window Lock. The Shaver should offer Maximum torque not be less than 29oz.in The shaver should be supplied with compatible shaver sterilization case. Input voltage of 100 to 240V, 50/60 Hz power consumption not more than 350VA. The variable speed foot pedal should be sturdy with a long connecting cable. The footpedal controls should include three standard operating modes, i.e. Forward, Reverse and Oscillation. The foot pedal should offer a blade window locking mode for enhanced safety during withdrawal of hand piece from joint space with blade mounted. Foot Pedal Page 2 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Consumables-Blades & Burs • Shaver System Should be supplied with 6 pieces of single use shaver blades of each of the following diameter i) 4.5mm Full radius Blade for ACL removal - 1pcs. ii) 3.5mm Cutter Blade for meniscus - 1pcs. iii) 5.5mm Incisor Blade -1pcs. iv) 4.5mm Syanovator Blade-1pcs. v) 4.0mm Abrader Burr -1pcs. vi) Cutting blade for saw-1pcs. vii) Electroblade -1 pc Hand Held Instruments All Hand Held Instruments should have single piece construction outer shaft and pin-less hinge design for distal tip, ensuring unsurpassed strength and cutting efficiency punches Basket Punch Duckbill straight Tip Profile – 2.52mm, Bite Width-3.17mm, Tip Width5.05mm Basket Punch Narrowline Upbiter 1.9mm, Bite width- 1.67mm, Tip width-2.89mm Basket Punch Duckling curved left 1.93mm, Bite width-3.17mm, Tip width-5mm Basket Punch Duckling curved right 1.93mm, Bite width- 3.17mm, Tip width-5mm Grasper:Cupped Grasper – 3.4mm with sliding lock mechanism Others Probe Straight 3.0mm Heavy hook with handle. ACL / PCL Drill Guide Systems: A comprehensive system suitable for Bone-Tendon-Bone as well as soft tissue grafts. Comprising of – Drill guide, aimers, and bullets - single hand operation – • • ACL Director Drill Guide Handle Director ACL Elbow Aimer ranging from 40 to 65 deg for drilling to the laser mark at the aimer’s elbow Director ACL Tip Aimer ranging from 40 to 65 deg for drilling to the tip of the aimer Director PCL Tibial Aimer with broad face tip that easily passes through notch & provides protection to posterior capsule during guide wire drilling Director PCL Femoral Aimer for outside in Drilling with medial incision, should have hoop tip to provide visual reference for the diameter of the fully reamed tunnel Director 4-Point Bullet with four sharp points for secure engagement of the guide at any angle Endoscopic cannulated drill bit 7mm for femoral tunnel drilling including calibration. Endoscopioc cannulated drill bit 7.5mm for femoral tunnel drilling including calibration. Page 3 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 • • • • • • • • • • • • • • • • • • • • • • • • • • • Endoscopic cannulated drill bit 8mm for femoral tunnel drilling including calibration Endoscopic cannulated drill bit 8.5mm for femoral tunnel drilling including calibration. Endoscopic cannulated drill bit 9mm for femoral tunnel drilling including calibration. Endoscopic cannulated drill bit 10mm for femoral tunnel drilling including calibration. Cannulated drill bit 7mm for tibial tunnel drilling Cannulated drill bit 7.5mm for tibial tunnel drilling Cannulated drill bit 8mm for tibial tunnel drilling Cannulated drill bit 8.5mm for tibial drilling Cannulated drill bit 9mm for tibial tunnel drilling Cannulated drill bit 10mm for tibial tunnel drilling Slotted sizing block with slots to measure graft ranging from 5mm to12mm with increment of 0.5mm. Also, includes the scale to measure the length of the graft Universal EndoFemoral Guide Handle Endofemoral Aimer, no offset 6mm Offset Endofemoral aimer 7mm Offset Endofemoral aimer Offset guide for precision tibial tunnel drilling, 2mm - 5mm Notchmaster Currette 8.0mm Tendon Stripper Slotted & Closed Depth Probe for measuring femoral tunnel length, Calibrated 10mm to 130mm in 2mm increments 4.5mm Endoscopic Cannulated Drill Bit Chondral Pick, Large 40 deg PCL Safety Stop PCL Elevator with Wire Catcher PCL Tibial Rasp PCL Tibial Currette, Closed PCL Tibial Currette, Open PCL Tibial & Femoral Aimer Graft Preparation Board with Tension Device Graft master Preparation Board Full Length Cutting Strip Endo Button Holder Graft Master Sliding Base – 02 no Suture Vise Suture Vise with Tensiometer Tissue Graspers - 02no Graft Master instruments Sterilization Tray Meniscal Stitcher Set A comprehensive system suitable for inside-out technique and should include: • • • • • • • Double Lumen Cannula,curved up-right Double Lumen Cannula,curved up-left Double lumen cannula ,straight Double Lumen cannula left/right Double lumen cannula,curved up/down Single cannula,2 included with set Thimble Page 4 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 • • Posterior Access Cannula Bending Tool Mosaicplasty System for treatment of cartilaginous defects A comprehensive system for treatment of focal cartilaginous defects using autogenous osteochondral transplantation technique. Suitable for Arthroscopic as well as open techniques • • • • • • • • • Tubular Chisels 4.5mm & 6.5mm Chisel Guards 4.5mm & 6.5mm Harvesting Tamps 4.5mm& 6.5mm Drill Guides 4.5mm & 6.5mm Dilators 4.5mm & 6.5mm Delivery Tamps 4.5mm & 6.5mm Trephines for hard bones 4.5mm & 6.5mm Trephine adapter Drill bits 4.5mm & 6.5mm Arthroscopic Coblation System Coblation based on low temperature BI-Polar Radio frequency technology. Should not have any need for the secondary patient grounding pad. The RF probe should have Multi Electrode Technology that will allow a uniform production of plasma The output voltage settings should be controlled by regulation on the generator from setting 1-10 The generator should have a feature of Automatic scope saver, i.e. when the probe comes too close to endoscope the controller pauses radiofrequency output and resumes radiofrequency output when the probe is returned to safe distance. The generator should have facility to use a foot control or a wireless footswitch for convenience and ease of use. There should be facility to adjust coblation and coagulation with different settings There should be a facility in the generator with inbuilt Timer device for minimally invasive treatments of Tendons and Fascia The generator should be able to take 42 different types of probes for open and minimally invasive arthroscopic procedures The generator should also have the facility to use a finger switch controlled probes. The RF generator should be able to take a wide range of probes for Tendon and fascia treatments also. Thermal Penetration should not be more than 150 Micron. The Unit should be USFDA and /or CE certified. The unit should be supplied with 2 pcs of Probes Arthroscopy Fluid Management System The Fluid management System offers to maintain& control intra-articular pressure regardless of varying outflow rates. The system can also be used with any arthroscopic inflow cannula and should include main control unit,disposable tubing sets, a wireless remote control, two Fluid Level Sensors The control unit should not require the user to increase distension pressure to achieve high flow rates.Outflow may be adjusted while maintaining the lowest distension pressure needed The Unit should have a LCD Display and should clearly depict High flow, Medium floe and Low Flows. Maximum flow rate of not less than 2.5 ltr./min Automatic Joint pressure maintenance up-to 150 mmHg Page 5 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Tubing Must be supplied with Disposable tube sets for inflow only (3pcs). Must be supplied with Disposable Tube sets for inflow and outflow (3pcs.). Shoulder Arthroscopy Instruments and Accessories. • Suture Manipulator which allows suture slide freely during extraction • Bankart Rasp • All purpose Grasper with low profile for Arthroscopic procedures • Tissue Elevator • Tissue penetrator cum suture retriever in below angles with Small Sharp penetration tip: 35Deg up 45 Deg Right 45 Deg left • Multifunctional Suture passer with provision of only 1 needle, which can hold the cuff & at the same time pass the suture & retrieve it in one step • Switching Stick 4.3mm, Non cannulated, 13” long • Open/Closed ended suture cutter, side loading with function of leaving sufficiently long tail without chance of cutting knot • Single hole knot pusher • Reusable cannulated obturator for 8.5mm cannula for easy cannula insertion • Reusable cannulated obturator for 5.5mm cannula for easy cannula insertion • Crochet hook • Shoulder Probe Disposable(s) 1. Threaded, preferably transparent Cannula & Obturator 8.5mm ,72mm long – 1 2. Threaded, preferably transparent Cannula with Obturator 5.5mm, 72 mm long – 1 Optional Shoulder Limb Positioner: Should be battery operated shoulder limb positioner Should offer instantaneous shoulder repositioning with in sterile zone itself Should deliver exceptional control of abduction, rotation & forward flexion in beach chair as well as lateral decubitus position Should come with a distal activation switch which can be attached to the sterile drape of the patient and can be used to reposition the shoulder by applying small pressure Should come with square rail clamps to connect it to the OT table Should have the provision for additional battery back up Should come with the battery charger Should come with traction accessory for the limb positioner Should come with a cart to make it comfortable to move from one place to another Digital High Definition Recording System The Full High-Definition Digital Documentation System should be a high-end computer system based on Windows embedded platform (for security purposes) designed specifically for recording, managing, editing and archiving surgical images and video in HD (1920x1080) resolution. The captured full high definition images & videos can be accessed from the hard drive for printing or saving onto multiple forms of external media which includes CD/DVD, USB Flash Drive or Hard Disk Drive(HDD) Page 6 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 It should have a touch screen display with 1TB Memory inclusive of External Hard Disk Drive (HDD) Video Formats compatible MPEG-1,MPEG – 2 and MPEG-4 (Minimum)and Still Image formats like JPEG(,jpg) and BMP(.bmp) Should offer multiple video signals like S Video, DVI, C-Video in both NTSC and PAL Formats. Video Signals available : DVI, S- Video, C-Video(Minimum) Functionality for Editing of Surgical Videos and Report Generation with Surgical Images Should be compatible to 100-240V 50/60 Hz Power requirements Wrist Arthroscopy Set Arthroscope 1.9mm & 30deg: Direct View Arthroscope Field of view: 80 deg Angle of view: 30 deg Diameter: 1.9mm Working length: 67mm Incorporated fibre optic light transmission Sapphire lens for improve scratch resistance Light post on opposite side of the direction of view with a j-lock fixation & stopcock 2.2mm short cannula, with flow port 2.2mm short trocar, sharp tip 2.2mm short obturator, conical tip Wrist Probe Wrist Arthroscopy Instruments Microvector Drill guide system Micro vector drill guide Offset drill guide K-wire guide, .045”(1.1mm) K-wire guide, .062”(1.6mm) K-wire guide, .125”(3.2mm) Microfracture Picks Microfracture Pick 90 deg, small Microfracture Pick 65 deg, small Microfracture Pick 40 deg, small Wrist Micro Hand Instrument Set Micro Grasper, Straight Micro Grasper, Up 10 deg Micro Punch, Straight Teardrop punch, right Teardrop punch, left Probe Page 7 of 7 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions X-Ray Machine DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR X-RAY MACHINE Compact, light weight easily transportable mobile radiographic unit Suitable for bedside Digital X-Ray for Emergency medicine department ,intensive care unit, trauma patients, operation theatres . The unit must included the following. 1. Power line connections : The unit should operate in single- phase power supply and should have overload protection. Plug in facility to any standard will outlet with automatic adaptation to line voltage 200 to 240 Volts 1.5 Amp plug. 2. The Generator : Must be Micro-processor controlled, high or ultra high frequency, output 10KW or above to give a constants output. 3. It should have a digital display of mA and KV and electronic timer. (i) KV range 40 KV to 125 KV (ii) mA range- 100 mA or more.( More will be preferred) (iii) Shortest exposure time (iv) KV and mA increase or decrease switch 4. X-ray Tube : Output should match the output of the generator, must have a rotating anode with at least 3000rpm and focal spot should be less then 1mm. Mention the heat storage capacity of the anode. Multi-leaf collimation should be possible with inbuilt light source. a) The collimator available in the equipment should have sufficient wattage of lamp for clear visualization of the area of interest in open areas like wards/ICUs b) It should have auto shut off facility to ensure longer life of the Collimator lamp. Collimotor tilt +/- 90 degree or more Self-diagnostic program with indicator for KV error, Filament error, tube heat thermal error 5. The unit must have an effective braking system for parking, transport and emergency braking. The tube stand must be fully counterbalanced with rotation in all directions. It must have an articulated arm for maximum positioning flexibility in any patient position. The angles in various planesto be specified by manufacturer. 6. All cables should be concealed in the arm system. 7. The exposure release switch should be detachable with a cord of at least 5 meters. 8. The unit must have good cassette storage facility 9. Grid, one each of size 12”x15” and 10”x12” ( ratio 6:1 Parallel grid) should be provided with each unit. 10. Two light weight Zero lead aprons should be provided with each unit. 11. Mention availability of spare parts, expertise in servicing and maintenance / repair facilities. 12. All technical information provided in the quotation must be substantiated with attached printed Original product data sheets, otherwise quotation may not be considered. 13. Quoted machine should be certified by AERB 14. USFDA and Europian CE 15. Must submit user list and performance report within last 5 years from major hospitals of repute Page 1 of 1 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Department of Pathology DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions Micro Tissue Array DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR MICRO TISSUE ARRAY Automated tissue microarray system with >50 Block Capacity Capbility for simultaneous loading, imaging, punching and drilling Automatic block and virtual slide matching Automatic slide localization on case center Core sizes varying from 0.6 to 2 or more mm TMA manual Kit should also be included. Capacity for 500 samples in one block from 0.6mm core Core extraction for molecular analysis Digital TMA with TMA evaluation software Page 1 of 1 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Department of Nuclear Medicine DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - A Tender Document Specifications, Terms and Conditions 128 Slice PET- CT DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 TECHNICAL SPECIFICATIONS FOR 128 SLICE PET-CT Supply Installation Testing and Commissioning of 128 slice Positron Emission Tomography/ Computed Tomography (PET/CT) Imaging System NOTE: PET-CT SCANNER AND LIMITED TURNKEY (As it where basis) SHOULD BE QUOTED AS A SINGLE PROJECT TO AVOID CONFUSION AT A LATER STAGE. Technical Specifications of Positron Emission Tomography/Computed Tomography (PET/CT) Imaging System 1. General Qualification Criteria: i. Nomenclature of standard equipment: A latest technology high–resolution state-of-the-art positron Emission Tomography Scanner integrated with 64 rows of solid state detectors with the capability of 128 slice CT generation. ii. Introductory year should be latest. iii. Must quote for its high-end latest technology model. iv. Original Datasheet, brochure and product literature. v. Latest Acquisition and Processing Software Version. vi. Quoted Model should be FDA approved. vii. AERB Certificate for the quoted model/ AERB type approval. viii. All Devices should be DICOM ready. Expected functions of standard equipment: Advanced positron Emission Tomography with integrated multi-slice CT studies for comprehensive Oncology, Cardiac, Respiratory, Abdominal, Neuro Studies including brain perfusion, general vascular and whole body imaging applications with optimal radiation dose efficiency. The system should be state of the art with fast acquisition speeds for imaging with good temporal resolution. The equipment will be complete with Patient Table, control and evaluation Unit, Computer system, latest user software and network module. The system should be installed on a l i m i t e d Turn Key basis or in the space provided by the institution, where it is to be installed according to the onsite feasibility. 2. i. ii. iii. iv. v. vi. vii. viii. x. xi. xii. xiii. xiv. PET Hardware Gantry should have integrated PET & CT hardware. Ring diameter should be 70 cm or more. The patient gantry aperture should be ≥ 70 cm and uniform for both PET and CT. Entire range of rotation times for full 360 degree with a minimum time of 0.4 or less. Laser alignment lights to define both internal and external scan planes, operate over full range of gantry and perpendicular relationship of coronal and axial lights. Controls located on all four sides. / Two each sides. Should have ECG gating and respiratory Gating with supporting hardware and Software. The PET scanner should employ non-hygroscopic high light yield (≥ 80%) and low decay time scintilator material like LYSO or LSO crystals for detecting 511 KeV gamma photons in coincidence with Time of Flight (TOF) technology. The system should have the capability of acquiring PET and CT images and fusion capabilities of both PET & CT images without moving the patients. System should have dynamic PET acquisition capability to acquire PET image independent of CT. Standard Carbon-fiber table top on the PET-CT gantry with patient‟s load bearing capacity of 180kg or more with ± 1 mm positional accuracy with indexed patients positioning system. Axial Field of view should be 16 cm or more. The transverse field of view should be ≥ 50 cm Page 1 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 xv. The scanner must have low power laser lines orthogonally mounted on the gantry for patient alignment and auto-contouring. The laser should be mounted in such a way that the patient can be positioned form either side of the gantry and the patient bed. xvi. Efficient Gantry cooling system for continuous running of the machine with tilt angle + 30 degree desired. 3. Performance Specifications: i. All specifications must comply with NEMA Standards Publication NU2-2007/NU-2012 or latest performance measurements without altering instrument parameters. QC Software to measure these parameters must be available in the system. ii. Axial spatial resolution at 1 cm from the central axis of the gantry should be ≤ 5 mm iii. System efficiency: sensitivity must be ≥ 5 cps/KBq at 350 KeV. iv. System Energy Resolution should be ≤ 12.0 % v. 3-D scatter Fraction should be ≤ 36% vi. Uniformity should be ≤ 2% variation. The coefficients of variations of Volume should be ≤ 5 % and System should be ≤ 1%. vii. During image reconstruction system should use Time-of-flight algorithms, when required for better lesion detectability. viii. System should be capable of reconstructing images at the rate of 20 to 40 images/ sec by using HD technology. ix. Attenuation correction should be CT based. Protocol/Algorithm for attenuation correction should be independent of metal/mA/IV contrast related artifacts 4. CT Hardware: The system should be the latest available slip-ring technology with 64 rows of solid state detectors. I. X-RAY GENERATOR Should be high frequency inverter type with power output sufficient to support and sustained continuous X ray generation for single continuous spiral acquisition time “ spiral on time” should be 100 seconds or more.( Better would be preferable). II. a) b) X-RAY TUBE: High performance CT X-ray tube is essential for uninterrupted long spirals. Anode heat storage capacity minimum should be 6.0 MHU, Tube Voltage between 80-140 kV, Maximum Tube Current at least 600 mA. c) Filter and beam limiting devices and other specific features to reduce radiation dose to the patient (with separate adult and pediatric modes) d) Specify the focal spot size and number according to IEC recommendations. e) Automatic selection of focal spots should be possible. III. Rotation time should be ≤ 0.4 sec IV. Image slice width should be from ≤ 1 mm to 10 mm. V. High contrast spatial resolution should be at 0% MTF 20 lp/cm, 10% MTF 15 lp/cm and 50% MTF10 lp/cm.(Specify actual resolution). VI. Low contrast spatial resolution 3 mm at 0.3%at 2 rads. Noise 0.3% at 2.5 rads. (Specify actual resolution). VII. Pitch factor (volume pitch) should be variable between 0.4 to 1.75 and should be freely selectable. Give details of all pitch selections. VIII. Standard Rotation times should be 0.4 to 2 sec for 360 degree. Specify the minimum and maximum with the range of pitch. Combinations of pitch slice thickness and spiral length should be easily selected by the user. The system should optimize the radiation dose and resolution for each selection. IX. Bolus triggered spiral acquisition should be possible. X. Single continuous spiral acquisition time “spiral on time” should be 100 seconds or more. XI. Gated cardiac and dynamic PET & CT imaging acquisition capability shall be provided. 4-D respiratory gating should be upgradable. Page 2 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 XII. Facility for reconstruction of PET and CT images and immediate display of images in 1024 x 1024 matrix parallel to acquisition in spiral mode in 512 x 512 or higher matrix. XIII. Patient Bed: a) Precision bed should be made of low attenuation carbon fiber and minimum sag of the patient table top. b) A separate flat carbon fiber table top with indexing should be provided for radiotherapy treatment planning. c) It should be able to bear 180 kg or more patient weight. d) The horizontal motion of the patient bed must be electrically motorized and computer controlled with an independent operator control option as well. Operator controls accessible from both sides of the patient must be provided for both horizontal and vertical movements. e) The horizontal travel of the bed should enable the full length scanning of a patient in one scan acquisition. Full body horizontal length should be ≥ 190 cm and vertical travel from 60 to 90 cm. f) A Digital readout of the horizontal and vertical position of the bed must exist and must be located near the aperture controls for the bed to provide ease in positioning g) Pediatric support, headrest, armrests, knee-leg support are to be provided (Med-tec or its equivalent). h) Attachable Flat table top on the PET-CT gantry with LASER system required software and complete sets of Immobilization devices. i) The List of Simulation accessories for PET-CT based treatment planning is as below. SR. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. DESCRIPTION N o . AIO COMPLETE SIMULATOR PACKAGE AIO Base plate in High Pressure Laminates(HPL) Head/ Neck solution Components Set of High Density head support (3 size with W / of lateral flaps) Set of High Density blocks and wedges (2 blocks and 2 wedges) Prone head support – coated Breast & Lung board Solution components Small base plate in high pressure laminates (HPL) Thorax abdomen – wedge 0 Thorax abdomen – wedge 5 Thorax abdomen – wedge 10 Thorax abdomen – wedge 15 Thorax abdomen- lateral support-0 Thorax abdomen- lateral support- 5(right / left) Thorax abdomen- lateral support- 10(right / left) Thorax abdomen- lateral support- 15(right / left) Thorax abdomen – Arm rest – High Thorax abdomen – Arm rest- Low Prone Breast Board Solution Component Prone Breast –caudal Cushion –standard 15cm clearance Prone Breast –caudal Cushion –standard 15cm clearance Prone Breast –caudal Cushion –standard 23cm clearance Prone Breast –caudal Cushion –standard 23cm clearance Prone Breast support cushion for contra lateral breast carbon fiber insert. Prone Breast lateral support (left/right) Prone Breast comfort wedge for contra lateral side Prone Head support - adjustable – 2 slots Page 3 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 32. 33. 34. Belly board & Pelvic Solution Component Belly & Pelvic Cushion Belly Board Insert – full Belly Board Insert – Large Belly Board Insert – Small Belly Board Insert hand grips 9 two pcs Belly& Pelvic Lateral support (left-right) Leg separator for AIO 2nd Generation Knee & Leg Positioning Cushions Knee & Leg Positioning Cushions- Low Knee & Leg Positioning Cushions- Wedge Knee & Leg Positioning Cushions- elevation 35. Knee & Leg Positioning Cushions-Base Plate Extension 36. Accessories – Hand Grip Grip pole system 25. 26 27. 28. 29. 30. 31. Accessories for individual Cushions 37. Side panels for individual cushions (4pcs) XIV. Computer system: (a) Latest high end reconstruction tools for pre and post processing of PET-CT data at main console. Facility of DVD & CD writing and image transferring with additional work station system. (b) LCD display monitor of at least 21 inch or more (diagonal) or more at all work stations. (c) Latest windows based DICOM compatible software to be provided for acquisition and processing. Latest and upgradeable software and hardware with all licenses (and upgrades for ten years) for all Oncology, Quantitative Cardiology including bolus tracking, CTA, coronary tree, plaque analysis, calcium scoring, bone mineral densitometry, myocardial perfusion quantification, coronary flow reserve and Quantitative Neurology including perfusion application should be provided. (d) Seamless connectivity to the existing server should be established for exporting the DICOM images and 4D Gated images from PET/CT to the RT planning systems for radiotherapy planning. (e) Connectivity with other DICOM enabled imaging modalities should be possible. This includes connectivity with PACS and HIS (HL7 compliant systems). (f) Computer Aided Detection (CAD) for lung nodule identification and growth rate calculation. (g) CT Fluoroscopy with monitor near gantry. Stereotactic software for localizing lesions in x, y, z planes compatible with third party Stereotactic frame. (h) Contouring facility for gross tumor volume and clinical target volume. Image and Radiotherapy structure transfer through network in DICOM to treatment planning system in Radiotherapy department. (i) Specialized Software: A l l p r o c e s s i n g w o r k m u s t h a v e Specialized Quantification software for Brain & cardiac studies (Quantification of Cerebral perfusion/cerebral blood flow and flow reserve, Quantification of metabolic parameters. Quantification of myocardial perfusion and flow reserve). 4DM or Equivalent for PET, SPECT, CT and MRI based myocardial perfusion study software with ECG gated studies, wall motion and wall thickening abnormality analysis/quantification with bulls eye map display. Separate Fusion software for registration of PET-CT images with imported Images and networking/ cabling with satisfactory demonstration. One additional computer (laptop) having core i7 or latest version processor, 4GB RAM, 500 GB or more HDD, High resolution 15 inch display and CD-DVD RW facility must be equipped with latest generation pharmacokinetic software and internal dose assessment software (OLINDA and MIRDOSE) as well as Imalytics or equivalent (Pharmacokinetic Modeling) Software. (j) The system should have a data editing facility for data acquired due to irregular heartbeat. Page 4 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 XV. Image storage server and processor a. Hardware should be high speed state of art processor with storage space not less than 10 terabyte or more storage, 4 GB RAM, with automatic archival systems & High speed volume rendering graphics card with minimum 2 GB RAM. b. The server should have either proprietary or reputed software (e.g. Terra Recon or equivalent), capable of advanced 3D processing and high end applications. c. Archiving: Image archiving system of ≥ 4 TB capacities capable of maintaining database of patients and images. Automatic Digital archiving of Data/studies on CD-R, CD-RW, DVD-R, DVD-RW along with compatible drives and 1000 CD-RW and 1000 DVD-RW to be provided. d. Latest anti-virus software should be loaded in the server for its protection and for protection of all client systems. The antivirus should be updated regularly for the next 10 years. e. A backup server facility should be available for retrieving the data when the main server crashes due to any reasons. Image Hard copy Device: a. Laser imager Dry chemistry DICOM with flexible formatting and software controlled operational capabilities with networking – latest model at the time of supply. Printing of films of 14”x17”, 10”x12”&10”x8” size in a resolution of 600 or more dpi. b. Two in nos. network Laser Color printers with compatible high capacity ink cartridges, with at least 16 million colors and 1200 dpi spatial resolution with accessories including workstation, digital DICOM compatible. c. Lamination machine with 100 no‟s of lamination roll for laminating paper images/reports. d. Thinking system TM of similar latest reporting software so as to enable comparison with older studies simultaneously: PET-CT processing and archiving software with all licenses and upgrades for a period of 10 years. XVI. Image transfer/networking i. DICOM send/receive with hospital PACS and with RTP server. ii. Query/retrieve iii. Basic print iv. HIS/RIS work list XVII. Post-Processing: Should be available in all workstations with all following applications 2-D, 3D including image zoom and pan, image manipulations, including averaging, reversal of gray-scale value, and mirroring; image filter functions, including advanced smooth algorithm and advanced bone removal algorithm. ii. Multi planar reconstruction of secondary views, with viewing perspectives in all planes. iii. Spatial alignment and visualization of two different data sets of one patient generated on different modalities or with different acquisition times. XVIII. Acquisition protocols: i. Acquisition Modes: Acquisition in 3D modes must include Static, Whole Body, Dynamic and Gated acquisition provisions. 3D whole Body acquisition protocols with prospective 3-D reconstruction algorithm. Iterative reconstruction technique should also be available. ii. Acquisition Protocols: The acquisition program should support pre-programmed scan protocols with acquisition and reconstruction parameters and patient information with simple, dynamic editing of parameters. These parameters would include all information necessary to acquire data on the PET scanner (e.g. scan duration, patient information, frame/list mode, bed motion), as well as information necessary for reconstruction. iii. Whole body Acquisition: Multi bed acquisitions (e.g. for the purpose of whole body oncology studies) should advance the bed from one position to the next Automatically iv. Dynamic Frame and List Mode Acquisition: The acquisition setup software must support multi-frame acquisitions of different (arbitrary) frame duration's with no loss of data between frames. v. Automatic Acquisition Start: The option to start an acquisition automatically must be provided. Page 5 of 18 i. DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 vi. Reconstruction Start: Image reconstruction should simultaneously start for the acquired images while acquisition is still in process. vii. viii. Reconstruction Time: mention time Pixel Size: The user should have the capability to specify the pixel size for reconstruction. The reconstruction program should support reconstruction in image sizes of at least 128x128 or higher. ix. ECG gating and respiratory gating should be part of the offer and are to be provided with necessary software. XIX. Work stations: i. ii. iii. iv. v. vi. vii. viii. ix. x. S.No Purpose of Work station Qty 1 2 Acquisition Common Processing Multimodality for Oncology, Cardiology and Neurology 1 5 3 RT Planning 1 4 Viewing Station with 60” LED monitor 1 In each of these 5 workstations all licenses (permanent site licenses) should be available for the aforesaid applications. Operator control functions: registration scheduling; protocol selection; reconstruction; standard evaluation applications; 3D display, Virtual Scopy including advanced colonoscopy, MPR, CMPR reconstruction during acquisition. Image fusion facility should also be incorporated on all workstations. Latest 4DM Cardiac PET – SPECT software. Computer aided diagnosis software for neurological applications with quantification ability (SISCOM or equivalent software) Provision to make DICOM/PDF/JPEG/AVI/MPEG digital output. Fusion software for CT/PET/SPECT/ MRI fusion and provision for multiple phases in 3D demonstration and treatment planning system. PET DICOM 3.0 or higher version must be implemented. It should have the ability to import MR/CT DICOM Data. Minimum size: minimum 21 inch or more diagonal LCD display for all work Stations. Superior quality furniture to be provided for all work stations – minimum of five chairs and one table with shelves for each work station. Lead glass window: One clear transparent 100 x 120 cm with adequate lead equivalence (as per AERB requirements) separating the PET/CT and the common console (total one in number). xi. Accessory steel cabinets for storage – 2 nos. XX. ACCESSORIES: 1. 4D compliant for Respiratory gating device for RT planning: The department of radiotherapy has Electa Infinity linear accelerator system in the same wing. Hence, the supplied system must be ready for non-invasive video based system using an infrared tracking camera and a reflective marker to accommodate both breath hold and free breathing pattern of patients breathing cycle (both prospective and re-prospective modes). It is the responsibility of the PET/CT vendor for the successful integration of 4D gated images with the Electa network system (for transfer of the same to the server of the RT planning system server). It is the responsibility of the PET/CT vendor to give all the necessary hardware and software‟s including required licenses for smooth integration of 4D gating of the PET/CT with RTP system and this should include license for PET/ SUV based contouring software in eclipse RTP. Page 6 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 2. FILM PRINTER: One Dry chemistry DICOM printer with flexible formatting and software controlled operational capabilities with networking – latest model at the time of supply. Printing of films of 14”x 17”, 10”x12” & 10”x8” size in a resolution of 600 or more dpi. 2 nos. packs of films of the above sized to be supplied. XX. List of components & consumables to be supplied with the PET/CT unit (to include in the bid): 1. ACCESSORIES : 1) Automatic Pressure injector – 01 (One) in nos. Digitally controlled CT contrast injection system (latest model – Dual Head) with Pedestal head mount, syringe heater with minimum 500 nos. of compatible syringe (200 ml) and connector for dual injection system. Anaesthesia Equipment (Boyles apparatuses) with crash cart and resuscitation Kit – One Multi function cardiac monitor (ECG, SPO2, & NIBP etc) Pulse Oxymeter, Defibrillator, Suction apparatus on trolley. 3) UPS: A 3 phase input/output UPS with Steal Maintenance Free (SMF) batteries for the complete system including CT with minimum 30 min. backup at full load should be provided, without discharge of battery voltage. 4) Infant Cradles: (Branded / Standard make) - 01(One) in nos. (Minimum 600 mm long and one 800 mm long cradle with stabilizing straps). 5) Phantoms and other accessories: For Quality control sets as required for Competent Authority (AERB, Mumbai) latest recommendation:-A complete sets of Phantoms and other accessories for CT & PET-CT Quality Assurance. a. For Spatial resolution: One nos. of Hamilton syringe (100 micro liter capacity), one packet of capillary tube (1mm diameter). b. For Sensitivity: A complete set of Sensitivity Phantom, c. For Scatter fraction, count-rate losses and randoms measurements : NEMA scatter fraction phantom d. For Image Quality and PET-CT image registration: Image Quality Phantom (IEC/NEMA 2001/2007 body phantom or equivalent). e. For Coincidence timing resolution for TOF positron emission tomography (If required): As per requirement of scanner. f. For 2-D–3-D Radioactivity concentration calibration: A Cylindrical Phantom ( fillable F-18 Phantom) g. For CT QC: CT Phantom (to test display profile with width, high contrast modulation and low contrast resolution, slice, image noise and image uniformity etc. h. For the kVp value and the half-value layer test (CT QC) : Type 1100 aluminium HVL filter set capable of adding 1–10 mm aluminium filtration to the beam. i. For Computed tomography number (CT QC): A phantom with areas of different densities, with, at a minimum, water, polyethylene, acrylic polymers, Teflon and air. 6) On site remote service diagnostic capabilities with broad band facility to be provided. 7) 12 leads ECG machine (standard make) – 01(One) sets 8) One set sources for calibration likes phantom (Germanium-68) Calibration Sources and other Sources, (calibrated for the date of installation) to last for least10 year-to be replaced as required. 9) Radiation detecting Alarms meter (standard imported make like Ludlum (Biodex, Capintec or better etc.) - 03 (Three) in nos 10) Radiation Sign: (Biodex, Capintec or better etc.) Each 07 (Seven) in nos. (Radiation Area, Radioactive Materials and other relevant messages caring) 11) Communication and Source security system - As required (five sets of High Resolution CCTV for security of radioactive source and monitoring of patients in post injection rooms with hard disk recording (at least one month‟s storage capacity) and multi image display monitor (32 inch ) & one set of public address system (with DVD player) along with 10 speakers placed in all rooms concealed in false ceiling. 2) 12) Latest Automatic Dosimetry (TLD) Reader along with annealing unit with 500 TLD Discs and 50 Discs Holder , TLD powder ( Lithium Fluoride / Calcium Fluoride Dysprosium / Calcium Fluoride Manganese ) with standard accessories ( Harshaw or any other equivalent make) : - 01(One) sets in nos Page 7 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 13) Lead Shielded (Minimum 2 mm thick) Waste Containers for PET Radiopharmaceutical waste (Biodex, Capintec or Ludlum) - 03(Three) nos. 14) Shielded L Bench – high energy type (PET compatible with lead glass (Biodex, Capintec or Ludlum): - 01(one) nos. 15) Shielded (Minimum 0.5 inch thick lead equivalent) Decay drum for long half life radioactive materials having energy 400 KeV or above (Biodex, Capintec or Ludlum): - 02(one) nos. 16) Digital Pocket dosimeter-Gamma & Beta: - 06(Six) nos. (Ludlum, Rotem, Biodex or Canberra) 17) Digital Portable radiation survey meter (Ludlum, Rotem or Victoreen) - 02(Two) nos. 18) Digital Handheld Contamination monitor (Ludlum, Rotem or Victoreen): - 01(one) nos. 19) Shielded syringe holders (Tungsten made) (Biodex, Capintec or Rotem): - one each for 2ml, 5 ml, 10ml 20) Shielding transport containers for FDG (Biodex, Capintec or Rotem):- One each for multi and single dose 21) Transport trolley for transport of shielding container (Biodex, Capintec or Rotem): - One each for Multidose and Single Vials 22) Light weight Radiation Protection Aprons with stand (Branded / Foreign made):- 05 (Five) in nos. (Both) 23) Area Zone Monitor (Ludlum, Rotem or Biodex): - 02 (Two) in nos. 24) Gonadal Shield, Thyroid Shield (of different sizes): - 04 (Four)in nos. each (Biodex, Capintec or Rotem) 25) PET Eye goggles with lead tinted glass (Biodex/Capintec/ Rotem)-02 (two) in nos. 26) Digital temperature and humidity control reader: - 03 (Three) in nos. (Branded/Standard made) 27) PET Dose Calibrator (CRC 55tR or equivalent) - 03 (Three) in nos. with one set of all three calibration sources (Ba-133, Co-57 and Cs-133) and one set of Molly Assay shield and other QC Phantoms and accessories for Dose Calibrator . 28) Lead lined glove (for PET Radiopharmaceutical Handling): - 02 (Two) sets in nos. (Biodex, Capintec or Ludlum) 29) Gun Monitor (Biodex, Capintec or Ludlum): - 01(One) in nos. 30) PET Dose Cabinet :-Heavy duty metal top table (SS or better) with provision of Dose Calibrator and LBench (Biodex, Capintec or Imported) installation with considering radiation safety requirements like lead bricks (Biodex, Capintec or Imported) - 01 (One) sets 31) Long Tool (72 inch or larger with lock and unlock option): - 01 (One) in nos. (Biodex, Capintec or Imported) 32) Decontamination Kit (Biodex, Capintec or Imported): - 02(One) in nos. 33) Various size forceps (12 and 18 inch) (Fisher or Branded): - Each 5 (five) in nos. 34) FDA approved mobile automatic PET tracer infusion system with all standard accessories and consumables (Medrad or Equivalent): 01 (One) in nos. 35) Glucometer (Imported): - 04 (Four) in nos. 36) Veinlite LED or Equivalen (Biodex, Capintec or Equivalent) -02 (two) in nos. 37) Digital Infusion Pump (Imported):- 02 (Two) in nos. 38) Automatic Blood pressure measuring apparatuses (Imported):- - 02 (Two) in nos. 39) Robotic Tools (hardware and software) for PET/CT guided biopsy with all standard accessories and consumables for first 50 cases (Latest available model) : - 01 sets 40) Electronic (fully Digital) weighing machine with Minimum range of 0-200kgs with SS top plate: - 02 (Two) in nos. Page 8 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 41) Post injection resting chair (Biodex or Equivalent): 05 nos. 42) Syringe carrier (0.25 Inch lead lined)(Biodex or Equivalent) :02 43) Injection Chair: 01(One) no. 44) PET Radioisotopes FUME HOOD with movable protective shield for 511 keV or above:01 in nos Specifications for Fume Hood: The fume hood should comply with the German International standard and safety requirements, the DIN 12924 NEU. Should be sliding window type with built-in double wall socket 220V,and water fitting with drainage basin, Size aprox 1200mm (W) x 820mm (D) x 2620 mm (H), Materials: The fume hood should be constructed of stainless steel(Type 304) .Inner chamber finished in chemical -resistant Epoxy paint and work surface covered with thick non glossy stainless steel sheet. Filter (Charcoal filters) and Exhaust to be lead suitable distance as per safety standards. Warranty & CMC as per tender terms. 45) High End Scanner (A3 size scanner with full optical resolution: (Optical Resolution of 9600 dpi by 9600 dpi across full A3 bed, and scan method single pass ) (HP, Canon or equivalent): - 01(One) in nos. 2. Supply of F-18 FDG isotope on site to be quoted along with this bid on yearly basis for 5 years and the payment will be made quarterly. The customer has all the discretion power to continue or discontinue the procurement of F-18 FDG after 01 year during the 5 year contract. 3. Supply of one 20 mCi (740 MBq) Gallium-68 PET generator and other chemicals used for labeling of peptides (DOTATATE & Similar molecules) for the 1st year after installation of facility and annual supply of same for next 4 years is also quoted separately on yearly basis. The contract for supply of Gallium-68 generator and other chemical necessary accessory components for DOTATATE/DOTANOC labeling is reviewed and renewed every year and the payment of which will be made on annual basis. 9. Germanium 68 pin source or other required source for the calibration of the system to be replaced as and when required for the period of warranty of 10 years. 10. PET RADIOPHARMACY SUPPLY *: Bid should include supply of F18 FDG dose for 10 patients (10mCi/patient at door step) per consignment for 225 days per annum for 5 years. Delivery will be as and when required in batches of 10 patient‟s dose. Bid should include supply of F-18 FDG up to site basis. The price for this should be quoted yearly basis separately for 5 years and the payment will be made quarterly. The customer has all the discretion powers to continue or discontinue the import of F-18 FDG after 1 year during the 5 year contract. a. b. Supply of one 20 mCi (740 MBq) Semi-automated Gallium-68 PET generator and other chemicals used for labeling of peptides (DOTATATE & Similar molecules) for 1st year after installation of facility and annual supply of same for next 4 years is also quoted separately on yearly basis. The contract for supply of Gallium-68 generator and other chemical necessary accessory components for DOTATATE/DOTANOC labeling is reviewed and renewed every year and the payment of which will be made on annual basis. Consumables for 68Ga-peptide synthesis: For 6 months (4 elutions per month) S.N. Name of the chemical Quantity Requirement 1. Metal free water 1 litre 3 bottles 2. Acetone 500ml 6 bottles Page 9 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 c. 3. Extra pure HCl 500ml 3 bottles 4. Ethanol 500ml 6 bottles 5. Ligand 1 mg 12-15 vials 6. Strata-XC 100/ pack 2 pks 7. RP C-18 or as per requirement 10/pack 10pks 8. 0.22 um filter 100/pack 1 box Any other necessary accessories required for the peptide synthesis should also be included in the list. 11. OPTIONAL ACCESSORIES: (TO BE QUOTED SEPARATELY)* *Cost of all the listed accessories should be provided separately as per General Conditions . 12. Limited Turn Key (As it where basis): a. Site Preparation: Design, planning, layout approval from competent authority and modification on turn-key basis, adhering to all the prescribed safety guidelines of competent authority (AERB) and GMP regulations like complete job of civil work at proposed PET-CT facility (like civil, flooring, false ceiling, wall finish/ painting, dust proof door and windows, electrical work, imported quality furniture (as per site requirement)) at available area designated for proposed PET-CT facility. Supply, Installation, Commissioning and seamless functioning of the entire system and also maintenance of turnkey project till completion of warranty and CMC of the system in all aspects. b. c. Civil work cost to be quoted separately as per actual requirements for the facility. Since the strict control of access to a medical facility is neither possible nor appropriate, safety within the facility should also be addressed through the design of circulation paths and functional relationships. d. Provisions for securing the personal belongings of staff, visitors, and patients/residents should be addressed. e. The physical environment should be designed to support the overall safety and security policies and protocols of the institution. Safety and security monitoring, when provided, should respect patient privacy and dignity. f. The Contractor must ensure that the works conform to the quality standards and to the satisfaction of the Employer. g. Quality Control: The works, plant and materials shall be subject to tests from time to time as per best practices in the industry. Wherever mentioned in the Contract, the tests must be carried out at the Contractor‟s expense. The materials shall be procured from reputed vendors approved by the Engineer. The Contractor must also supply samples to the Engineer for his approval and also carry out the tests as and when required by the Engineer. h. Periodic Progress and review: Periodical review of the progress of the project shall be carried out in every 21 days and at any time desired by the Employer. For this purpose the Contractor shall prepare and submit the progress reports as stated in the Contract. i. Superior quality furniture (Branded, Imported quality) to be provided for all work stations-Minimum two chairs and one table with shelves for each work station. j. Steel Almirahs for storage (Branded, Imported Quality) – five nos. k. Digital piped music -In all rooms with central Music Player of Sony or equivalent quality. l. Lead Glass window as recommended and required: Separating the scanner and console. m. Work station furniture (Godrej/ Standard make) Superior quality All the materials / equipments used in turnkey should be of international standards. The samples of the items should be submitted to the appropriate committee / Head of Nuclear Medicine, DRRMLIMS, for approval and supply. Institute has discretion to decide about the brand that would be used. Page 10 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 The contractor shall keep at site a latest copy of the following: a) b) Contractor‟s Documents that shall include but not limited to the technical documents as follows: Construction Drawings Detailed including any modifications etc. c) List of Codes, standards and specifications being followed. d) Documents required to satisfy all regulatory approvals, 13. Guarantee/ Warranty/ Maintenance for complete system: a) Guaranty for complete system – 05 Yrs. (The complete system incl. all accessories, X-Ray Tube & PET detectors, crystal and radioactive sources, and UPS with batteries after satisfactory functioning of the equipment.)The firm will be responsible for import of spare parts, custom clearance including taxes and transportation to the hospital during warranty and CMC period without any additional payment by the institute. b) Uptimes guarantee – 96 % uptime guarantees with provision of penalty. c) The firm shall make arrangements for demonstrations before trial run and at the time of commissioning of the systems and equipment. d) For Delays : if the supplier fails to deliver any or all of the goods or perform the services within the time period(s) specified in the contract, the purchaser shall, without prejudice to its other remedies under the contract, deduct from the contract price, as liquidated damages, a sum equivalent to 0.5 percent of the delivered price of the delayed goods or under formed services for each week of delay or part thereof until actual delivery or Performance, up to a maximum deduction of 10 (ten) percent of the delayed goods or services contract price. Once the maximum is reached, the purchaser may consider termination of the contract. e) For shortfall in equipment performance: Recovery shall be made from the supplier for not meeting the guaranteed Performance/productivity of the equipment during actual testing as detailed in „Technical Specifications‟, a sum equivalent to one percent of the cost of the equipment/plant for each unit of shortfall in the guaranteed Performance/productivity, where applicable. f) Comprehensive maintenance contract (CMC): - For whole system including x-ray tube replacement as and when required and accessories for a period of five (05) years after the expiry of warranty period. g) The Peripherals/accessories, electronics/electrical consumables (leads, probes, batteries etc), costly general consumables,3-D phantom source and rod source, and batteries of UPS will also form part of the warranty and thereafter CMC. Services, repairs and maintenance of all third party items will be the sole responsibility of primary vendor. Replacement/replenishment of the coolant for gantry will also form the part of warranty as well as CMC. h) The CMC contract shall be executed after the warranty period; however, rates shall be fixed from now. i) The supplier should provide comprehensive maintenance contract (with spare/consumables/Accessories including labour charges) inclusive of customs and all taxes for the next 5 year (i.e. year 6 to 10 inclusive). The CMC shall be in the range of 3 to 4.5% of the (FOB + Rupees value of the local items if any excluding turnkey) with annual inflation in the range of 5 to 8 % of the original CMC value. The entire item including consumables criteria will be accepted. j) Uptime Warranty: 96 % uptime, penalty in case fail to provide uptime of equipment, in which warranty extended for double duration will be levied or 10,000/- per working day subtracted from the CMC payment in case fail to provide uptime of equipment . th k) The vendor would be required to quote for CMC value which commence from sixth year onwards till 10 year. l) After sale service to be available locally in Lucknow with availability of an onsite certified PET-CT trained engineer (certificate has to produce along with bid) on same model. m) The Principal manufacturer to give undertaking that they will maintain and service the equipment in case Indian agent / supplier fails to provide. n) No. of trained and certified PET-CT service engineer on same model of equipment in North India especially in Lucknow. o) No. of Installation in India or Abroad.- Please provide a comprehensive list with their contact details 14. Final decision will be taken after on site satisfactory demonstration of the quoted model. 15. Availability of spares for Minimum 10 yrs. (Mandatory) – Page 11 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 16. Warranty: The supplier shall give a comprehensive warranty for five years after installation and satisfactory function of the system including all local items (and battery replacements). During warranty, if the firm is not able to provide 96% uptime, the warranty will be extended in double proportion to the period the equipment was non-functional. 17. Training: a) Period: - Four weeks (excluding journey period) at Society of Nuclear medicine and molecular imaging (SNMMI),USA or EANM,Vienna certified training centres having (128 slice or more PET-CT scanner) PET/CT and qualified/experienced Nuclear Medicine Faculty and Staff. b) No of Persons: -Four (04) in nos. c) India/Abroad: -Abroad (USA or Europe only) d) A comprehensive list of certified training centers to be provided along with this bid. e) On Site Training: - On site training by application specialist in phases to technical and clinical staff initially and also on as and when required basis till the satisfaction of the user. f) Two weeks training in best available site having same model available in India: - For Three (03) Persons. 18. Books /Journal:-Two (02) International journals of Nuclear medicine or related to Nuclear medicine subscription for 10 years. 19. CD Cassettes: -10 or more Training CDs/DVDs. 20. Operating and Service Manual: - All the operating and service manuals in duplicates to be provided by the vendor at the time of handing over the machine and their accessories. 21. Others -ISDN line with connectivity and paid up rental for 10 years. 22.Upgradeability:All software & hard ware upgrades to be provided free of cost for ten (10) Years. 23. The following documents are must be attached along with the technical bid a) Availability of similar Equipment (In India or abroad ) :b) Product literature of available similar model :c) User certificate ( From Three Users Minimum) required: d) List of institution/ hospital where such equipments are installed and being functioning: e) If item is to be procured on PAC basis give justifications (e.g.: Compatibility with existing equipmen f) Certified that QR covers available brands in the market and is not specific to one brand. 24. GENERAL CONDITIONS & REQUIREMENTS : In the above specifications wherever the word „shall‟ is mentioned, it is taken in the meaning that the required feature / facility / procedure / specification / standard is mandatory. All claims regarding meeting of the specifications shall be duly supported by appropriate, latest technical catalogues / brochures from the manufacturer. Simply stating that the equipment meets the specifications is not sufficient and any such quotations will be summarily rejected. Computer printed documents or laser printouts will not be accepted as technical catalogues / brochures. During the warranty period, software upgrades shall be provided free of cost wherever applicable. The vendors shall submit a compliance statement point wise in regard to the specifications asked for in the tender. It will be responsibility of the vendors to go through all the tender requirements carefully and accordingly address each and every point about their compliance. The compliance statement shall preferably be made in an Excel worksheet or any other tabular format for easy evaluation. A softcopy of the submitted (signed) compliance statement must be provided on a CD. The Supplier/Vendor should post a field service engineer based at Pondicherry for 24x7 equipment maintenance. The Engineer should be authorized by the vendor and respective training certificate of the engineer should be submitted at the time of commissioning a. Since the strict control of access to a medical facility is neither possible nor appropriate, safety within the facility should also be addressed through the design of circulation paths and functional relationships. Page 12 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 b. Provisions for securing the personal belongings of staff, visitors, and patients/residents should be c. addressed. The physical environment should be designed to support the overall safety and security policies and protocols of the institution. Safety and security monitoring, when provided, should respect patient privacy and dignity. I. • Maintenance and Training requirements for systems, machines and equipment The Contractor shall maintain all systems, machines and equipment during the defects liability period. The developer shall see to it that all the warranty and guaranty cards are properly filled and duly submitted to the Employer along with their maintenance manuals. • The Contractor shall train the staff of the Employer for the new systems, machines and equipment procured for the hospital. The minimum training period for the hospital staff should be 3 months which can be varied by the Employer. • The Contractor shall make arrangements for demonstrations before trial run and at the time of commissioning of the systems and equipment. • Operation and Maintenance Manual shall be supplied to the Employer for the new equipment and latest machinery. • These manuals shall contain in sufficient details, the procedures for operation and the maintenance schedule for the medical and other equipment such as air conditioning etc. II. Periodical Progress review Periodical review of the progress of the project shall be carried out in every 21 days and at any time desired by the Employer. For this purpose the Contractor shall prepare and submit the progress reports as stated in the Contract. The contractor shall keep at site a latest copy of the following: a. b. c. d. e. f. g. h. i. j. k. l. m. n. o. p. q. r. s. Contractor‟s Documents that shall include but not limited to the technical documents as follows: Construction Drawings Detailed including any modifications etc. List of Codes, standards and specifications being followed. Documents required to satisfy all regulatory approvals, A complete set of "as-built" records of the execution of the Works, showing the exact as-built locations, sizes and details of the work as executed. Any other document which the Engineer instructs from time to time Design documents as mentioned above. Operation and Maintenance Manuals Records of Contractor's Personnel, Labor and Equipment Charts, detailed descriptions of progress, including, each stage of design, procurement, manufacture, delivery, construction, erection, testing, commissioning and trial operation; Cash Flow Analysis of the past and estimate for the balance work on a fortnight basis. Photographs showing the status of manufacture and of progress on the Site; For the manufacture of each main item of Plant and Materials, the name of the manufacturer, location, percentage progress, and the actual or expected dates of: commencement of manufacture, Contractor's inspections, tests, and shipment and arrival at the Site; Copies of quality assurance documents, test results and certificates of Materials List of Variations, notices given under Sub-Clause 2.4 (Employer's Claims) and notices given under Sub-Clause 20.1 (Contractor's Claims); t. Safety statistics, including details of any hazardous incidents and activities relating to environmental aspects and public relations; Page 13 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 III. Quality Control The Contractor must ensure that the works conform to the quality standards and to the satisfaction of the Employer. The contractor shall submit his quality plan in accordance with the above The works, plant and materials shall be subject to tests from time to time as per best practices in the industry. Wherever mentioned in the Contract, the tests must be carried out at the Contractor‟s expense. The materials shall be procured from reputed vendors approved by the Engineer. The Contractor must also supply samples to the Engineer for his approval and also carry out the tests as and when required by the Engineer. The following furniture (both medical and general) room wise distribution as provided in Annexure A shall be supplied. The vendor shall propose the specification for approval of DRRMLIMS. The items to be quoted under medical and general furniture should be manufactured by the standard medical & general manufacturers and samples of the items should be submitted to the appropriate committee to be constituted by DR.RMLIMS for approval and supply. SCOPE OF WORK GENERAL A u g m e n t a t i o n of PET-CT Scanner in the Nuclear Medicine Department including necessary civil, electrical works & all services and SITC of Equipments like PET CT at DR.RMLIMS, Lucknow. WORK CONTENT Brief Scope The project involves procurement, installation, testing and commissioning of equipments, and construction of treatment rooms and associated facilities at the Oncology Building at DR.RMLIMS. The project has the following components. • Procurement, installation, testing and commissioning of Positron Emission Tomography / Computed Tomography (PET / CT) Imaging System. • Procurement, installation, testing and commissioning of Medical equipment & furniture. • Latest model Ceiling mounted LCD Projector with USB drive retractable white screen at Satellite work station cum seminar room. • Providing desktop computers with latest configuration, UPS, printers, printer cum fax cum Xerox machine etc. • Telephone connection (direct line with STD Facility) and intercom (all hardware included). The scope of work consists Project planning, design, construction, procurement, installation, testing and commissioning of equipments, and integrated commissioning of the PET-CT Facility. Necessary building work is to be designed and executed as per relevant codes, Technical Specifications, conceptual / layout drawings and AERB regulations. The work shall, inter-alia, include the following: i. The construction design shall be appropriate to the type of equipment to be installed and shall conform to AERB regulations. ii. Approval of Atomic Energy Regulatory Board shall be obtained for the design, construction, installation and commissioning of equipment. iii. Detailed design engineering including architectural design and construction documents, structural engineering, electrical engineering, heating ventilation and air conditioning plans, medical gases and manifold plan, plan for the central sterile services department, communication and networking plan, fire detection and protection plan and waste management etc. iv. Site clearance and dismantling of obstructions etc., before commencement of work. v. Getting approvals / permissions / permits of the statutory / local / governmental agencies including AERB for using the facility for patient care purposes. vi. Building construction and installation of all services and making all the building services fully and functionally operative. vii. Procurement, installation, testing and commissioning of medical equipment as per specifications provided. Page 14 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 viii. Procurement and installation of furniture and fixtures including internal and external signage‟s. ix. All aspects of quality assurance, including testing of medical equipments and other components of the work shall be done and the report to be given to DR.RMLIMS. Manufactures test data certifying compliance with specified performance requirements and with requirements of the contract document should be also given to DR.RMLIMS. x. Project Management to ensure completion of Project as per the specified timelines. xi. Submission of the completion (i.e. „as-built‟) drawings and other related documents. A soft copy in Auto CAD or other similar software‟s shall also be submitted. xii. Clearance of site before Handing over of the facilities after fulfilling all the obligations under “Employer‟s Requirement”. xiii. Making good any defect (if any) in Defects Liability Period. CIVIL WORKS Bidder shall be responsible for the design and construction of the proposed nuclear medicine block. Bidders are strongly advised to visit the site and carry out the assessment of works. All material should be of high quality and sample should get approved by DR.RMLIMS commencing the use. Bidder shall be responsible for complete design of facility as per AERB requirement and other statutory requirements. The bidder should ensure structural stability of existing building with 3 levels (G+2) building. All the walls/partitions of the PET-CT Facility should be as per AERB norms. Total area of construction will be around 250 square meters. Bidder shall be responsible for the interior design including construction of counters, doors with and without lead lining, windows and any other work required for the smooth functioning of the nuclear medicine department. List of Approved makes Wall tiles – Kajaria or Johnson Floor tiles - Kajaria or Johnson AIR- CONDITIONING ,DUCTING AND FALSE CEILING Bidder shall be responsible for air conditioning inside the proposed nuclear medicine department. The existing chiller has capacity to cater the demand of the proposed block. Bidder shall be responsible for supply, installation, testing and commission of the HVAC system ie AHU, ducting and other related work .Temperature should be 22 ± 2 degree Celsius and relative humidity should be 50 ± 5%.Total tonnage required will be around 15 TR. Proper insulation of ducting has to be done by the bidder. Bidder shall be responsible for the false ceiling work inside the proposed block. Bidder has to carry out all the works as per latest national/international standards. Heat dissipation of equipment in to scanner room should be considered in the design. Humidity control should be provided as required. 1 2 Air Handling Unit Fan Coil/Cassette Unit 3 4 5 6 7 Centrifugal fans Thermal Heat Recovery Wheel M/S. & GI Pipes Ball valve (up to 30 mm) Butterfly valve Blue Star, Carrier, Voltas, VTS, Caryaire, Edgetech, Zeco Blue Star, Voltas, Caryaire, Mukund, Edgetech, Zeco, Midea Nikotra, Comfrei, Kruger ABB, Bry Air, Novelaire Tata Steel, Jindal Danfoss, RB, Sant, Rapid Intervlalve, C&R, Audco, Advance, Econsto 8 9 10 11 12 Pressure Gauge Thermometer Ball valve (Fan Coil Units) Auto Air Vent Valve Grille/diffuser Fiebig, Wika, H Guru. Emerald, H Guru, Feibig Rapid Control, Emerald, Castel Rapid Control, RB, Anergy Caryaire, Ravistar, Air Master, Dynacraft, Page 15 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 13 14 Caryaire, Ravistar, Air Master, Dynacraft Air Breeze / Ajanta Armacell, Armaflex, Eurobatex, K Flex 18 Volume/Fire Damper Closed Cell Elastomeric Insulation along with adhesive Fibreglass (Foil Faced) Expanded Polystyrene (TF Two way motorized valve for AHU & FCUs Room Thermostat/Humidistat 19 20 Flow Switch Factory Fabricated Ducts. Honeywell, Siemens, Rapid Control Zeco, Rollarstar, Camduct, Western Air 15 16 17 UP Twiga, Owens Corning, Kimmco Beardsell, Qualty thermopack, Coolite Tour Andover , Johnson Control , Honeywell, Siemens Tour Andover , Johnson Control, Honeywell, Siemens ELECTRICAL WORKS Bidder shall be responsible for the design, installation, testing, and commissioning of the electrical system for the proposed block. Consignee will provide required three phase line from the existing substation. Approximate distance from the nearest substation is 500 m .All remain works including cabling, distribution panel, isolators, MCBs, Switches has to be done by the bidder. Bidder shall be responsible for electrical works and other cabling necessary for the efficient working of the equipment inside the proposed block. .Circuit breaker shall be ACB/MCCB. Panel board should be with 2 mm thick CRCA sheet manufactured by panel fabricator having valid CPRI certificate for fabricating similar type of panel. All work shall be carried out as per latest CPWD specification. The PET/CT is to be supported with UPS with 30 minutes back up (full load) The major power requirements Maximum power requirement for PET/CT - 150 KVA Maximum List of Approved makes Cables Gloster / Universal / Polycab Wires Finolex / RR kabe l/ Gloster / Anchor Switches - Legrand / MK / Crabtree FIRE FIGHTING Bidder should provide effective firefighting system. Bidder should extend fire sprinkler system from the existing system to the new block except equipment room. Equipment room should be supported with fire extinguisher. Safety clearance from the concerned authority has to be obtained by the bidder. Water should be drawn from the existing fire tank. PLUMBING WORKS All plumbing works associated with proper functioning of PET-CT Facility has to be carried out by the vendor. Proper drainage will be the responsibility of the vendor. Plumbing requirement for the active toilet has to be done by the bidder in accordance with the AERB norms. Water mains have to be drawn from the existing building. VENTILATION AND LIGHTING: Proper Ventilation system has to be provided for hot lab, Decontamination room, Waste room etc. Light fitting should be mirror reflector type. Light fittings should be Philips / Wipro / GE. Design criteria to be specified with the proposal by the Tenderer The design of the Tenderer shall be of international standards and should be complete in all respects as per international best practices. Detailed design including the design criteria, codes and standards and specifications of the materials to be used for the design should be submitted by the Tenderer along with his proposal. Other documents as detailed in Employer‟s Requirements and Sub-clause 4.2.4 of Instruction to Tenderers should be submitted along with the design. DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Page 16 of 18 Reference to the Standard Codes of Practice All Standards, Technical Specifications and Codes of practice referred to shall be latest editions including all applicable official amendments and revisions. The Contractor shall make available at site all relevant Indian Standard Codes of practice as applicable. Wherever Indian Standards do not cover some particular aspects of design/ construction, relevant International Standards shall be referred to. The contractor shall make available at site such standard codes of practice. In case of discrepancy among Standard codes of practice, Technical Specifications and provisions in Employer‟s Requirements, the order of precedence shall be as below: i) Provision in General Requirements of Employer‟s Requirements ii) Technical Specifications in Employer‟s Requirements, iii) Standard Codes of Practice. In case of discrepancy in reference to Standard Codes of Practice, the order of precedence shall be BIS, IRC, BS, ASTM, DIN iV) All radiation equipment installation should follow AERB requirement. 2.2.4 Dimensions The levels, measurements and other information concerning the existing site as shown on the conceptual / layout drawings are believed to be correct, but the tenderer should verify them for himself and also examine the nature of the ground as no claim or allowance whatsoever shall be entertained on account of any errors or omissions and commissions in the levels or strata turning out different from what is shown on the drawings. TIME SCHEDULE The tenderer shall submit with the tender “Time Schedule” for completion of various portions of works. This schedule is to be within the overall completion period of 06 months. The detailed program in the form of a Critical Path Method (CPM) network shall include all activities starting from design to completion. Supply, Installation, Testing and Commissioning of Positron Emission Tomography/Computed Tomography (PET/CT) Imaging System Primary vendor quote for the supply, installation and commissioning of (A) A state-of-the-art 128-slice PET/CT, and Site Preparation: Designing, planning and constructions on turnkey basis, adhering to all the prescribed AERB safety guidelines and local regulations. • • • • • • Installing and commissioning of the PET/CT equipment and its accessories. Getting approvals from the local and national regulatory authorities including AERB approval for using the facility for patient care purposes. AERB approval for full commissioning of the equipment. Certification: Type Approval Certificate / No objection certificate from AERB Mumbai for the equipment should be available. It is the responsibility of the vendor to obtain AERB certificates. Also it is the responsibility of the vendor to do all the quality assurance tests on the equipment and the report should be given to DR.RMLIMS. Manufactures test data certifying compliance with specified performance requirements and with requirements of the contract document should be also given to DR.RMLIMS. All equipment, accessories, other ancillary equipment needed, warranty, turnkey and accessories under turnkey should be part of tender. The turnkey part and the supply FDG and Gallium-68 generator with their accessories for 5 years should be quoted separately. However, the final bid evaluation will be done based on the final prices of all the above parts. All the Application, Operating and Service manuals in duplicates should be provided by the vendor at the time of handing over the machine. At least one of these manual sets to be provided in computer DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 • readable format, preferably as Word for Windows format document. Supply of F-18 FDG isotope on site to be quoted separately along with this bid on yearly basis for 5 years and the payment will be made quarterly. The customer has all the discretion power to continue or discontinue the procurement of F-18 FDG after 1 year during the 5 year contract. Page 17 of 18 • Supply of one 20 mCi Gallium-68 PET generator and other chemicals used for labeling of peptides st (DOTATATE & Similar molecules) for the 1 year after installation of facility and annual supply of same for next 4 years is also quoted separately on yearly basis. The contract for supply of Gallium-68 generator and other chemical necessary accessory components for DOTATATE/DOTANOC labeling is reviewed and renewed every year and the payment of which will be made on annual basis. • Upgradeability: The quoted price should include software (including licenses) and hardware upgrades to be provided free of cost for ten years (during warranty period and CAMC period). Any options or added facilities not indicated in the specifications may also be given. Any improved modifications or updated versions of the system can be included in the quotations. DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Page 18 of 18 DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Enclosure-C Tender Adv. Ref No.RMLIMS/MM(eq)/14-15/3745 Make & Model No. Quoted PRICE: INR ………… Accessories in INR ……… Price + Accessories Amount ……… VAT/CST (applicable as per rules) ……… Amount (Price + Accessories Amount+ VAT/CST) ……… CMC (From 6th to 10th Year) ………… 6th ………… 7th ……… 8th ………… 9th ………… 10th ………… Total CMC ………… Service Tax on CMC ( applicable as per rules ) ……… CMC Price + Service Tax ………… Amount + CMC with Service Tax (6th to 10thyrs) in INR ……… Total Cost [Amount + CMC with Service Tax (6th to 10thyrs) in INR] --------- DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure-D Tender Adv. Ref No.RMLIMS/MM(eq)/14-15/3745 Dated:26.12.2014 EQUIPMENT Name: Make & Model No. Quoted FOB PRICE: SGD/JPY/Euro/USD/YEN etc. ……… * Accessories (if any) in Forigen Currency …….. Price + Accessories ……… Less Indian Agency Commission (if any) …… Net FOB Value …… Add Freight & Insurance ……… Total CIP / CIF Value ……… * Custom Duty ……… * Clearence Charges …… * Add Indian Agency Commission ……… Cost of Equipment + Custom Duty Charges & Custom Clearance Charges ……… * Accessories (if any) in INR ……… VAT/CST ( applicable as per rules ) ………… Total Accessories Price (INR) + VAT/CST ………… CMC (From 6th to 10th Year) ………… 6th ………… 7th ……… 8th ……… 9th ……… 10th ………… Total CMC Value ……… Service Tax on CMC ( applicable as per rules ) ……… Total CMC Price (6th to 10thyrs) + Service Tax ………… NOTE:- (*) Conditions applied. * Custom Duty will be paid on actual or Quoted rate, whichever is less. * Clearance Charges will be paid on actual or maximum @ 1% of FOB Price, whichever is less. * Indian Agency Commission will be paid on the conversion rate of comparative chart on which basis the P.O. will be awarded. The IAC will be paid after final installation of the machine. * Accessories Detail List with Price may be annexed with this format. DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Enclosure-E Note:-Each & Every page or paper of the tender document should be serially numbered, siged & stamped by an authorized signatory of the bidder. Fill check list in proper manner as per below format:- S.No. 1 2 3 4 5 6 Description VAT Registration certificate duly attested copy by a Gazetted Officer should also be enclosed. VAT, Income Tax clearance certificate. The affidavit from a notary that the firm has never been black listed must be attached along with the tender failing which the tender will be rejected and no correspondence will be entertained in this regard. The tenderers should clearly state whether he/they are manufacturer, accredited agents, or sole representative (indicating the name of Principal) on the top of the Bid and the authority letter must be attached with technical bid, but authorization as Agent/ Distributor / Representative for this tender only will not be accepted.” The tenderer shall specify regarding after sales services within the Guarantee/Warranty period. Earnest Money be paid in shape of DD, TDR, FDR, drawn in favour of the "Finance Controller, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow", payable at Lucknow, U.P. India as mentioned in the tender notification. Page (From) Page (To) DR. RAM MANOHAR LOHIA INSTITUTE OF MEDICAL SCIENCES VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW PHONES: 0522-4918555, 4918504, FAX 0522-4918506 Annexure - B LETTER OF SUBMISSION Tender No. RMLIMS/MM(eq)/14-15/3745 Dated 26.12.2014 Full Name of the firm______________________________ Address ________________________________________ _________________________________________ Phone & Fax No.__________________________________ To, The Director, Dr. Ram Manohar Lohia Institute of Medical Sciences, Vibhooti Khand, Gomti Nagar, Lucknow. Dear Sir, I/We hereby offer to supply the stores detailed in the schedule hereafter or such portion there of as you may specify for the acceptance of tender and the price given in the said schedule and agreement to hold this offer open till ______________________________. I/We shall be bound by a communication of acceptance dispatched within the prescribed time. I/We have understood the instructions to tenderer and the conditions of contract and have thoroughly examined the specifications/drawings and / or / pattern quoted in the schedule here to and am/ are fully aware of the stores required and my/ our offer is to supply stores strictly in accordance with requirement Yours faithfully, (Signature of Tenderer) Dated :
Similar documents
Welcome to Dr. Ram Manohar Lohia Institute of Medical Sciences
The tender document may download from the institute's website & submitted with a Demand Draft of [Rs. 1,050 (Rs. One Thousand fifty only) {inclusive VAT} (Non-Refundable)]. Last date of download of...
More information