Straumann® Dental Implant System: One system
Transcription
Straumann® Dental Implant System: One system
Straumann ® Dental implant system ONE SYSTEM – ONE INSTRUMENT KIT – ALL INDICATIONS* For all indications*! The Straumann® Dental Implant System offers you and your patients efficient and esthetic implant-borne restorations for a wide range of indications, giving you the flexibility you need in your treatment. Single tooth missing Partially edentulous Fully edentulous * From single teeth to edentulous solutions SIMPLICITY AND EFFICIENCY: SOFT TISSUE LEVEL SOLUTIONS Straumann® Soft Tissue Level is one of the most widely used soft tissue implant lines. With 10-year Designed to save time and increase e fficiency in your practice 2 long-term results for SLA®1, it is the ideal partner in your practice and the right choice for your patient treatment. Soft Tissue Level implant aims at reducing chair time and minimizing treatment complexity Designed to provide integrated soft tissue management through built-in machined collar design High treatment success and patient satisfaction supported by strong scientific evidence 3 Treatment workflow on soft tissue level IMPLANT SOLUTIONs Placement of an implant Healing cap Placement of a provisional abutment 2 REDUCING TREATMENT COMPLEXITY Take advantage of the easy accessibility to the implant by working at soft tissue level Lean prosthetic portfolio supported by the implant design Abutment-level impression makes workflow efficient and number of patient visits can be minimized 4 Simple impression taking and abutment placement due to the connection at soft tissue level Conventional impression taking Insertion of the abutment Crown in place 3 ESTHETICS AND FLEXIBILTY: BONE LEVEL IMPLANT SOLUTIONS The Straumann® Bone Level implant line provides you with additional flexibility to deliver an optimal Excellent esthetics due to bone preservation 5,6 and smart soft tissue management esthetic solution to patients. Bone Level implants complement the Straumann® Soft Tissue Level portfolio to offer you wide treatment flexibility and manifold options. Stable crestal bone supporting esthetic outcome 5,6 Exclusive self-guiding CrossFit ® connection designed for a precise fit and stability A wide range of treatment options with the convenience of a confident solution at bone level Bone level implant The precise and self-guiding CrossFit ® connection 4 FOR A WIDE RANGE OF TREATMENT OPTIONS Designed for outstanding esthetic results and flexibility in restorative procedures Broad range of materials and restorative options designed for an optimal result in every treatment step Natural appearance through full ceramic restorations with customized or standard abutments Smart soft tissue management from start to finish with Consistent Emergence Profiles™ Consistent Emergence Profiles™ Consistently matching geometries throughout the entire workflow Eases the fabrication of temporary and final restorations Excellent esthetic results 5,6 Healing abutment Temporary restoration Final restoration 5 A LEADING SURFACE INNOVATION: SLActive® For years, implants with the SLA® surface have delivered excellent results and high implant success rates.7,8 Straumann followed this state-of-the-art development in implant dentistry with the SLActive ® surface, the next generation in surface technology. Promoting faster osseointegration and providing higher predictability, SLActive has become a cen® tral feature of the implant portfolio. 6 MORE CONFIDENCE THROUGH HIGHER PREDICTABILITY 9,10,11 SLActive ® designed to deliver: Higher security and faster osseointegration for every indication 9,10,12–17 Reduced healing times from 6 – 8 weeks down to 3 – 4 weeks11 Increased treatment predictability in critical protocols 9 DRIVING MATERIAL INNOVATION: ROXOLID ® Roxolid®, the new “DNA” of implant materials, is a titanium-zirconium alloy, specifically developed for dental implantology. Roxolid® is designed to widen your treatment options with small diameter implants. Mechanical tests have demonstrated higher tensile ROXOLID ® THE NEW “DNA” OF IMPLANT MATERIALS Confidence when placing small diameter implants Flexibility of having more treatment options Designed to increase patients’ acceptance of implant treatment and fatigue strength of Roxolid® implants compared to titanium grade 4 implants.18,19 In combination with the SLActive ® surface, Roxolid® brings high strength and excellent o sseointegration properties to the Straumann® Dental Implant System portfolio. 7 SIMPLICITY: ONE SYSTEM The proven Straumann® Dental Implant System (SDIS) is a broad portfolio of Soft Tissue and Bone Level implants that allows you to deliver an optimal treatment to your patients. Implant portfolio Most common clinical situations The classic implant for o ne-stage surgery The implant for flexible healing protocols The implant for immediate placement and superior primary stability The implant for confidence and esthetics at bone level Straumann® Standard Straumann® Standard Plus Straumann® Tapered Effect Straumann® Bone Level Anterior region Posterior region Small interdental space (NN) Thin mucosa biotype Bone augmentation with simultaneous implant placement Submerged healing Thick mucosa biotype Non-submerged healing Immediate implant placement in extraction socket Internal sinus lift 8 Highly recommended Recommended Please note that the size limitations according to the instructions for use of each Straumann® product apply and must be observed. Each Straumann® product must be used in accordance with the instructions for use provided by Straumann. It is the practitioner’s responsibility to use the device in accordance with these instructions for use and to determine if the device fits the individual patient situation. SIMPLICITY: ONE INSTRUMENT KIT For your convenience, the appropriate Straumann® surgical instrument kit can be used for all implant lines of the Straumann Dental Implant System, in ® both conventional and guided surgery. FOR EASE OF HANDLING The easy-to-read user guide ensures a reliable working sequence through color-coded arrows and silicone sleeves The cassette can be packed to reflect the working procedure (which is performed either using the handpiece or manually with the ratchet) Clear illustrations and drill length stops confirm, at a glance, that the arrangement of instruments, screws and healing caps is complete and correct Straumann ® Instrument Kit Straumann ® Surgical Cassette Straumann ® Guided Surgery Cassette 9 PROSTHETIC OPTIONS COVERING A Variety OF INDICATIONS Choose between different materials and follow CHOOSE THE ACCURATE PROSTHETIC OPTION your preferred workflow! The Straumann® prosthet- Solid abutments are designed to facilitate the restoration ics portfolio offers you the esthetics and flexibility of implants Flexible and comprehensive synOcta ® portfolio offers the you need in your practice. perfect restorative solution Easy to achieve esthetics with anatomic abutments Prosthetics portfolio Titanium Cementable Solid synOcta ® Cementable synOcta ® Angled Screw-retained Single tooth Cemented Basic Solutions LOCATOR® Removable overdentures Fully edentulous Soft Tissue Level implants Fixed overdentures Bone Level implants CADCAM Screw-retained Partially edentulous Cemented Anatomic Bar Advanced Retentive anchor Individualized bar Natural-looking esthetics with CADCAM abutments Flexible and comprehensive Multi-Base portfolio designed for perfectly fitting screw-retained multiple unit restorations Due to their standard designs, LOCATOR® and bar components are ready to use in a variety of indications Gold synOcta ® 1.5 Multi-Base Straumann® CARES® synOcta ® Gold Screw-retained bridge Ceramics Cobalt-chrome Gold Anatomic IPS e.max ® Abutment CADCAM Solutions Straumann® CARES® Screw-retained bridge Premium Solutions Telescopic constructions synOcta ® 1.5 Multi-Base Gold Straumann® CARES ® Screw-retained Dolder ® Bar Straumann® CARES ® Screw-retained bridge RELIABILITY: BONE CONTROL DESIGN™ Bone Control Design™ is an implant design which The Straumann® Dental Implant System is your reli- has been applied consistently to the Straumann® able partner in implant treatment, giving you simple Dental Implant System. It is built on 5 key factors for and convenient solutions – for your success! bone preservation and thus provides a crucial foundation for esthetic results and long-term success. Optimize crestal bone preservation 1. Respecting the biological distance 5 4a. Microgap control Soft Tissue Level 4b. Microgap control Bone Level 2. Optimal position of smooth and rough surface interface 5. Implant surface osteoconductivity 3. Biomechanical implant design 12 references 1 Fischer K. ITI World Symposium. 2010 15–17 Apr; Geneva; Switzerland. 2 Applicable to simple cases according to the ITI rating. 3 Straumann® SLA Scientific Evidence first edition (2011). 4 A pplicable to simple cases according to the ITI rating and using a solid 5 12 daily dental practice. J. Oral Implantol. 2010;36(4):305–314. 13 regeneration in dehiscence-type defects at chemically modified (SLActive) B user D et al. Stability of Contour Augmentation and Esthetic Outcomes and conventional SLA titanium implants: A pilot study in dogs. Journal of a Prospective Study With Early Implant Placement Postextraction. Clinical Periodontology. 2007;34(1):78–86. 14 8 Becker J. Effects of surface hydrophilicity and microtopography on early Cordaro L et al. Submerged vs non-submerged healing of implants for stages of soft and hard tissue integration at non-submerged titanium single tooth replacement in the aesthetic zone: results from a multicentre implants: An immunohistochemical study in dogs. Journal of Periodontology. B ornstein M.M. et al. Early loading of non-submerged titanium implants 2007;78(11):2171–2184. 15 Histological and immunohistochemical analysis of initial and early spective study in partially edentulous patients. Clin. Oral Implants Res. subepithelial connective tissue attachment at chemically modified 2005;16:631–638. and conventional SLA® titanium implants. A pilot study in dogs. Clinical Oral Implants Research. 2007;11(3):245–455. Roccuzzo M. et al. Early loading of sandblasted and acid-etched implants: 16 Histological and immunohistochemical analysis of initial and early osseous G aneles J, Zöllner A, Jackowski J, ten Bruggenkate C, Beagle J, Guerra integration at chemically modified and conventional SLA® titanium implants: F. Immediate and early loading of Straumann implants with a chemically Preliminary results of a pilot study in dogs. Clinical Oral Implants Research. 1-year results from a prospective multicenter study. Clin. Oral Impl. Res. 2007;11(4):481–488. 17 B user D, Broggini N, Wieland M, Schenk RK, Denzer AJ, Cochran DL, 2008;19:1119–1128. Hoffmann B, Lussi A, Steinemann SG. Enhanced bone apposition to B ornstein MM, Wittneben JG, Brägger U, Buser D. Early loading at a chemically modified SLA titanium surface. J. Dent. Res. 2004 Jul;83(7): 529–533. 21 days of non-submerged titanium implants with a chemically modified 11 S chwarz F, Herten M, Sager M, Wieland M, Dard M, Becker J. Clin. Oral Implants Res. 2008;19:148–152. modified surface (SLActive ®) in the posterior mandible and maxilla: 10 S chwarz F, Herten M, Sager M, Wieland M, Dard M, Becker J. with a sandblasted and acid-etched surface. 5-year results of a pro- a randomized-controlled double-blind split-mouth study. Five-year results. 9 S chwarz F, Ferrari D, Herten M, Mihatovic I, Wieland M, Sager M, J. Periodontol. 2011;82(3):342–349. RCT. Oral presentation at Annual Meeting of EAO, 2010 in Glasgow (UK). 7 S chwarz F, Herten M, Sager M, Wieland M, Dard M, Becker J. Bone abutment. of Implant-supported Single Crowns in the Esthetic Zone. 3-Year Results of 6 Luongo G, Oteri G. A noninterventional study documenting use and success of implants with a new chemically modified titanium surface in sandblasted and acid-etched surface: 3-year results of a prospective 18 Norm ASTM F67 (states min. tensile strength of annealed titanium). study in the posterior mandible. J. Periodontol. 2010 Jun;81(6):809–818. 19 Data on file, used for all Straumann® titanium and Roxolid ® implants. O ates TW, Valderrama P, Bischof M, Nedir R, Jones A, Simpson J, Toutenburg H, Cochran DL. Enhanced implant stability with a chemically modified SLA® surface: a randomized pilot study. The International Journal of Oral & Maxillofacial Implants. 2007;22(5):755–760. 3 International Headquarters Institut Straumann AG Peter Merian-Weg 12 CH-4002 Basel, Switzerland Phone +41 (0)61 965 11 11 Fax +41 (0)61 965 11 01 Dolder ® is a registered trademark from Prof. Eugen Dolder, former director, School of Dentistry of Zurich. IPS e.max ® is a registered trademark of Ivoclar Vivadent AG, Liechtenstein. LOCATOR ® is a registered trademark of Zest Anchors, Inc., USA. Some items of the Straumann ® Dental Implant System are not available in all countries. © Institut Straumann AG, 2012. All rights reserved. Straumann ® and/or other trademarks and logos from Straumann ® mentioned herein are the trademarks or registered trademarks of Straumann Holding AG and/or its affiliates. All rights reserved. Straumann products are CE marked 03/12 152.912/en BG21012 w w w. s t rau m an n .c o m
Similar documents
Straumann Dental Implant System (SDIS) Brochure
The Straumann® Surgical Kit and Prosthetic Kit can be used for all implant lines of the Straumann Dental Implant System. For ease of use, you need only one restorative kit for both Soft Tissue Lev...
More informationSTRAUMANN® SOFT TISSUE LEVEL IMPLANT SYSTEM Time
pp SLActive ®: – Next generation in surface technology reducing healing times down to 3 – 4 weeks.10 SCIENTIFICALLY SUPPORTED materials pp Titanium grade 4: A well documented material in implant ...
More information