Brochure
Transcription
Brochure
JLI-UV exhaust hood WWW.JEVEN.COM PAGE 2 JEVEN Kitchen ventilation Table of Contents Product description & Product code 3 Functioning principle, Parts 4 Dimensions 5 Positioning, Design Service 6 Exhaust air 7 Pressure loss & sound data, Lights 7 We want to help you in design of ventilation by offering Jeven designer service to your disposal. Design Service helps in design and makes unique proposal solution with Jeven products. Contact us: All rights reserved jeven@jeven.fi 010 231 2030 WWW.JEVEN.COM JEVEN Kitchen ventilation JLI-UV Exhaust Hood PRODUCT DESCRIPTION The Jeven JLI-UV hoods has been designed for kitchens where exhaust-only hoods are needed or supply air units are impossible to install. JLI-UV is equipped with exhaust units with damper plates and measurement taps. In addition to JCE cyclone filter, the JLI-UV canopy also has a UV-filter unit for removing grease and impurities from the exhaust air. JCE cyclone filters can be easily washed in a dishwasher. LIGHTS AND FILTERS The JLI-UV hood comes with ultraviolet filters, JCE cyclonic filters, a stainless steel mesh filter, a pressure guard switch and lights. The UV filter unit includes a UV frame with UV-tubes as well as a UV control unit and panel. MATERIAL The canopy’s base material is stainless steel, AISI 304. The side panels can be made of stainless steel (JLI-R-UV) or laminated glass (JLI-S-UV). ACCESSORIES Covering boards to enclose the area between the top of the hood and the ceiling. PRODUCT CODE JLI - R - UV - 2000 x 1500 x 540 - 1x400 - 1080 m3/h - CB Material R=Stainless steel S=Glass UV=UV-filter unit Length Width Height Number and size of the exhaust air connections Exhaust air flow, m3/h Accessories CB=Covering boards WWW.JEVEN.COM All rights reserved PAGE 3 PAGE 4 JEVEN Kitchen ventilation JLI-UV Exhaust Hood FUNCTIONING PRINCIPLE 3 1. Heat and impurities rise into the hood. 2 2. The effective three-phase UV-filter extracts the grease and impurities from the exhaust air. 3. Clean air is exhausted into the ducts. 1 PARTS 1. Outer casing 2. Lights 3. Light cable (approx. 2m) 4. UV filter unit 5. Exhaust air connection and airflow damper 6. Ceiling console 7. Hanging bracket 8. Pressure sensor 9. Pressure measuring hosepipe 10. UV control center 11. UV touch screen 12. Control panel cable 13. Electrical cable from the UV unit to the control center 14. The main power connecting cable which must be equipped with safety fuse 15. Electrical cable from the pressure sensor to the UV control centre 5 1 2 4 6 7 10 14 13 15 9 8 3 11 12 All rights reserved WWW.JEVEN.COM JEVEN Kitchen ventilation PAGE 5 JLI-UV Exhaust Hood DIMENSIONS Wall hood A L 40 0 40 0 B L-L JCE-UV Module 1 height width JCE-UV 75 Module 2 2x36W 2x36W width L (module) length Island type hood A Y Module 2 Y-Y height 2x58W JCE-UV 0 40 0 JCE-UV 2x58W 40 width B Module 1 width Y (module) length Hoods length, width and A, B-dimensions can be chosen freely. Max. module size is 3000mm x 1800mm. Filters require 500 mm of free space to open. B mm WWW.JEVEN.COM 75 All rights reserved Height F øD G mm mm mm mm Emin mm Kmin mm M mm 200 540 500 160 100 400 340 65 500 500 330 540 290 200 125 550 500 250 150 550 350 350 110 110 PAGE 6 JEVEN Kitchen ventilation JLI-UV Exhaust Hood X The size of the hood is determined by the size of the kitchen equipment. The overhang depends on the type of quipment and the distance between the hood and the equipment. For this type of equipment, the overhang should be at least 300 mm. The typical distance between the hood side and the floor is 2100-2200 mm. If the equipment has any doors that open upwards, make sure there is enough distance to the canopy. 2100-2200 POSITIONING >0.2 *X >400 Oven DESIGN SERVICE Jeven Design Service helps you choose the best solution for your professional kitchen project. Simply email us a drawing of the kitchen lay-out and a list of the cooking equipment to jeven@jeven.fi We will do all the calculations and prepare all the necessary drawings of the canopies. This service is always free of charge to you. All rights reserved WWW.JEVEN.COM JEVEN Kitchen ventilation PAGE 7 JLI-UV Exhaust Hood LIGHTS 2 1 40 The number of cyclones depends on the air outflow. The nominal airflow per cyclone is about 60 l/s (210 m³/h). With that airflow the pressure difference across the cyclone is 40-60 Pa. The factory always delivers an appropriate number of cyclones so that the pressure drop in every cyclone is in that range. 6 units of 39 W UV lamps are always included. The UV filter unit’s exterior dimensions stay always the same. 85 EXHAUST AIR B Recommended exhaust flow / spigot Spigot size ø mm 400 Exhaust flow l/s m3/h - 500 - 1800 Pressure loss Pa 40-60 1 Light fixture as standard, IP 54-67 T8: B=111mm,(1x18W, 1x36W, 1x58W) B=168mm, (2x18W, 2x36W, 2x58W) Colour temperature 840(Cool White) 2 About 2m cable, type EKK 3x1,5 Pressure loss Ps (Pa) PRESSURE LOSS AND SOUND DATA 120 100 Number of filter modules 2 3 4 5 678 1 80 70 60 50 By default, every hood module comes with a light fixture. The light fixture has a cable which should be connected to a junction box with a cable lock. The junction box is not included. dB(A) =50 dB(A) =40 40 30 80 100 160 200 320 400 500 800 l/s 120 240 600 300 500 700 1000 1400 2400 m³/h 1800 Sound power level Lw in each octave band is computed by adding the corresponding factor, Kok to the sound power level LpA. Lw= LpA+Kok. Factor, Kok 125 6 ±3 250 5 ±3 500 1000 2000 4000 4 -2 -9 -16 ±2 ±2 ±3 ±4 3.8.2015 Hz Kok tol. WWW.JEVEN.COM All rights reserved
Similar documents
Jeven JLI-TURBO technicalbroc
Product Description System Jeven JLI-Turbo hood has been designed for kitchens where exhaust hoods with high effiency grease extracting are needed and supply air units on the hoods are impossible t...
More informationJ S K I c o n d e n s a t i o n h o o d w i t h s u p p l y a i r
Simply email us a drawing of the kitchen lay-out and a list of the cooking equipment to jeven@jeven.fi We will do all the calculations and prepare all the necessary drawings of the canopies. This s...
More information