PAVIMENTOS CONTINUOS DE ALTA RESISTENCIA HEAVY
Transcription
PAVIMENTOS CONTINUOS DE ALTA RESISTENCIA HEAVY
PAVIME S US FLOORING O U IN T N O C Y HEAVY-DUT SISTENCIA S DE ALTA RE O U IN T N O C NTOS EPOXY FLOORS 2 Heavy-duty continuous floorings, thought for the most demanding uses TECNOFLOOR’s Industrial floor coatings are designed to pass the most demanding tests in frequent and intensive usage conditions. The loads and stresses that heavy-duty floorings are subject to on a daily basis, in combination with the safety, health and hygiene standards they must meet have lead us to, through a long research process, develop this range of flooring solutions, ideal for any application requiring a durable, resistant and visually appealing finishing. Some specific uses: INDUSTRIAL | manufacturing | distribution | storage | common areas | restrooms | food processing plants | restaurants | kitchen areas | luncheonettes | RESIDENTIAL | garages | basements | kitchens | porches | walkways | washing facilities | gyms | SALES AREAS | exhibition and sales rooms | rooms with high operator, forklift and/or carrier transit | vending machine areas | maintenance areas | storage | walkways | patios | aviation hangars | museums | television studios | areas with animals | PÚBLICO | fire stations | wastewater treatment | parks and recreation | police departments | penitentiary facilities | education centers | classrooms | cafeterias | locker rooms | museums | exhibition halls | MOTOR | dealerships | oil change services | car wash | repair workshops | retail shops | parking lots | fleet service areas CONTINUOUS HEAVY DUTY FLOORING | PAVIMENTOS CONTINUOS DE ALTA RESISTENCIA 3 Pavimentos continuos de alta resistencia pensados para los usos más exigentes Los pavimentos industriales TECNOFLOOR están concebidos para superar las pruebas más exigentes de un uso intensivo frecuente. Las cargas y tensiones diarias que deben soportar junto con los requerimientos de seguridad, salud e higiene, nos han llevado, tras una largo proceso de investigación, a desarrollar esta gama de pavimentos idóneos para cualquier aplicación en la que se requiera durabilidad, resistencia y un acabado decorativo. Algunos usos específicos: industrial | fabricación | distribución | almacenaje | zonas comunes | baños | plantas de procesamiento de alimentos| restaurantes | áreas de cocina | comedores | residencial | garajes | sótanos | cocinas | patios | porches | pasarelas | lavaderos | gimnasios | comercial | salas de exposición y venta | salas con tráfico intenso de personas, carros y/o carretillas | zonas con máquinas expendedoras | áreas de mantenimiento | almacenes |pasarelas | patios | hangares | museos | estudios de televisión | zonas con animales | público | bomberos | tratamiento de aguas | parques y recreación | departamentos de policía | centros penitenciarios | centros educativos | aulas |cafeterías | vestuarios | museos | salas de exposiciones | motor | concesionarios | servicios cambio de aceite | lavacoches | talleres de reparación | tiendas detalle | aparcamientos | áreas de servicio de flota EPOXY FLOORS TECNOFLOOR Tw-3040 WATER BASE BASE AGUA Water-based epoxy coating Revestimiento epoxi base acuosa TECNOFLOOR T-3020 is a fluid, pigmented, waterbased epoxy coating with optimal chemical and mechanical resistance properties. It has been especially designed for application in garages, parking lots, and vehicle transit areas, over flooring surfaces subject to the strictest decontamination and cleaning standards, and in the chemical and food processing industries. TECNOFLOOR T-3020 es un revestimiento epoxi pigmentado, fluido, en base acuosa con buenas resistencias químicas y mecánicas. Está especialmente diseñado para aplicaciones en garajes, aparcamientos, zonas de tráfico rodado, pavimentos con elevados requisitos de descontaminación y limpieza, industria química y alimentaria. 4 Possible Applications Aplicaciones posibles Avaliable colors Colores disponibles Paint Pintura RAL 3016 Multilayer Multicapa Multilayer Plus Multicapa Plus RAL 6001 RAL 7042 Advantages Ventajas •Water-based, odorless. •Base agua, sin olores. •Highly-fluid product, quick and easy to apply. •Elevada fluidez que permite una fácil y rápida aplicación del producto. •Finishing versatility, it can be used for multilayer, or painting purposes. •Easy to maintain, clean and decontaminate. •Optimal chemical resistance. •High coating capability. •Optimal adherence to concrete. •Allows water vapor diffusion. •Suitable for application on underlayment surfaces with a certain level of humidity. •Versatilidad en el acabado, puede aplicarse como multicapa o pintura. •Facilidad de mantenimiento, limpieza y descontaminación. •Buena resistencia química. •Elevado poder cubriente. •Buena adherencia al hormigón. •Permite transmisión del vapor de agua. •Puede aplicarse en soportes con cierto grado de humedad. CONTINUOUS HEAVY DUTY FLOORING | PAVIMENTOS CONTINUOS DE ALTA RESISTENCIA TECNOFLOOR T-3020 100% SOLID SÓLIDOS Epoxy 100% solid coating Revestimiento epoxi 100% sólidos TECNOFLOOR T-3020 is a pigmented, fluid, 100% high chemical and mechanical resistance solids epoxy coating for application over concrete flooring surfaces. It has been especially designed for application as protective coating over concrete surfaces and in heavy-duty industrial flooring finishings. TECNOFLOOR T-3020 es un revestimiento epoxi pigmentado, fluido, 100% sólidos de alta resistencia química y mecánica para el recubrimiento de pavimentos de hormigón. Está especialmente diseñado como recubrimiento de protección del hormigón y acabado de pavimentos industriales donde se requieran altas prestaciones. Possible Applications Aplicaciones posibles Avaliable colors Colores disponibles Paint Pintura Multilayer Multicapa standard colors RAL 3016 RAL 6001 Advantages Multilayer Plus Multicapa Plus 5 Self-Leveling Autonivelante special colors RAL 7042 RAL RANGE - CARTA RAL Ventajas •100% sólidos. •100% sólidos. •Solvent/odor free. •Exento de disolventes, sin olores. •Highly-fluid product, quick and easy to apply. •Elevada fluidez que permite una fácil y rápida aplicación del producto. •Finishing versatility, it can be used for selfleveling, multilayer, or painting purposes. •Easy to maintain, clean and decontaminate. •Optimal chemical resistance. •High coating power. •Optimal adherence to concrete. •Possibility to produce according to RAL color chart. •Versatilidad en el acabado, puede aplicarse como autonivelante, multicapa o pintura. •Facilidad de mantenimiento, limpieza y descontaminación. •Elevadas resistencias químicas. •Elevado poder cubriente. •Buena adherencia en el hormigón. •Posibilidad de fabricación según carta RAL. EPOXY FLOORS TECNOFLOOR T-3020 100% SOLID SÓLIDOS Epoxy 100% solids with antistatic properties Revestimiento epoxi 100% sólidos con propiedades antiestáticas With the same basis as TECNOFLOOR T-3020’s, we have modified its formulation to develop a continual flooring solution that, thanks to its zero-electric charge retention properties, is suitable for environments where these are an essential requirement. It is ideal for application in areas such as electronic laboratories, white rooms, surgery rooms, offices with sensible technologies, production lines, etc... Con la misma base del TECNOFLOOR T-3020 hemos modificado su formulación para desarrollar un pavimento continuo que no retiene carga eléctrica significativa, lo que permite su uso en entornos en los que éste sea un requisito fundamental. Se recomienda su aplicación en áreas como laboratorios electrónicos, salas blancas, quirófanos, oficinas con tecnología sensible, líneas de producción, etc ... 6 Possible Applications Aplicaciones posibles Avaliable colors Colores disponibles Self-Leveling Autonivelante standard colors RAL 3016 RAL 6001 special colors RAL 7042 In combination with an earth connection, this graphite-fiber rich formula is perfect for rendering antistatic surfaces. Esta fórmula contiene en su interior un elevado número de fibras de grafito que, unidas a una toma de tierra, proporcionan una superficie antiestática. RAL RANGE - CARTA RAL CONTINUOUS HEAVY DUTY FLOORING | PAVIMENTOS CONTINUOS DE ALTA RESISTENCIA Comparative|Comparativa Paint Pintura TECNOFLOOR Tw-3040 Water based epoxy coating Revestimiento epoxi base acuosa TECNOFLOOR T-3020 100% solids epoxy coating Revestimiento epoxi 100% solidos TECNOFLOOR T-3020 AS Antistatic 100% solids coating Rev. 100% sólidos antiestático Multilayer Multicapa Multilayer PLUS Multicapa PLUS S - E A Self-Leveling Autonivelante - - yes | si yes | si - A - yes | si yes | si optional | opcional S - - - E - - - A - - - S E S: shore | dureza E: economy | economía optional | opcional A: anti-slip | antideslizante Finishes|Acabados Painting Application Aplicación como Pintura Multilayer Application Aplicación como Multicapa 7 Self-Leveling Application Aplicación como Autonivelante Anti-Slip Self-Leveling Application Aplicación como Autonivelante Antideslizante EPOXY FLOORS Step-by-Step Application Guide Guía de aplicación paso a paso 1 Surface Preparation | Preparación del Soporte The underlayment surface must always be subject to a mechanical preparatory process: sandblasting, milling, or shot-blasting (see table in this page). Siempre debe realizarse una preparación mecánica de la superficie: lijado, fresado o granallado (ver tabla en esta página). Existing cracks, cavities or flaws, if any, must be filled and compacted previously, using repair mortar prepared with a combination of our PRIMER EP-1020 with 0.3 ~ 0.5 aggregate or calcium carbonate (1:1). This mixture ensures a high-strength quick-drying solution. En el caso de existencia de fisuras, coqueras o desperfectos se procederá a su relleno y compactado mediante un mortero de reparación que se realiza mezclando nuestra imprimación PRIMER EP-1020 con árido 0,3 ~ 0,5 o carbonato cálcico (1:1). Esta mezcla proporciona gran dureza y un rápido secado. Please contact our technical department to clarify any doubts you may have regarding before using the product. We are looking forward to help you. Siempre que tenga dudas le aconsejamos que antes de realizar cualquier acción se ponga en contacto con nuestro departamento técnico donde gustosamente le atenderemos. 8 Surface preparation guidance table | Tabla orientativa preparación del soporte TECNOFLOOR Tw-3040 Water based epoxy coating Revestimiento epoxi base acuosa TECNOFLOOR T-3020 100% solids epoxy coating Revestimiento epoxi 100% solidos TECNOFLOOR T-3020 AS Antistatic 100% solids coating Rev. 100% sólidos antiestático Application Aplicacion Action Required Acción requerida All | Todas Sand the surface, clean and vacuum Lijar la superficie, limpiar y aspirar P Self-Leveling | Autonivelante Grinding or milling the surface and clean / suck Lijar, granallar o fresar la superficie, limpiar y aspirar P Paint, multilayer or multilayer plus | Pintura, multicapa o multicapa plus Sand the surface, clean and vacuum Lijar la superficie, limpiar y aspirar NP All | Todas Sand the surface, clean and vacuum Lijar la superficie, limpiar y aspirar P Self-Leveling | Autonivelante Grinding or milling the surface and clean / suck Lijar, granallar o fresar la superficie, limpiar y aspirar NP Self-Leveling | Autonivelante Sand the surface, clean and vacuum Lijar la superficie, limpiar y aspirar P& NP P: porous surface | soporte poroso NP: non porous surface | soporte no poroso CONTINUOUS HEAVY DUTY FLOORING | PAVIMENTOS CONTINUOS DE ALTA RESISTENCIA 2 Priming | Imprimación Application of our priming products (see table in this page) is required for sealing purposes, to ensure proper bonding with the underlayment surface, and, therefore, a good anchoring and the proper surface finishing. The primer layer can be applied using a brush, roller or airlesstype unit. Es necesaria la aplicación de nuestras imprimaciones (ver tabla en esta página) para facilitar el sellado y la adherencia al soporte, consiguiendo así un buen anclaje y un acabado superficial correcto. Su aplicación se puede realizar con brocha, rodillo o equipo tipo airless. En el caso de superficies de hormigón, éste debe haber finalizado su proceso de curado de 28 días posteriores a su vertido, o en todo caso, se deberá comprobar el grado de humedad máximo permisible en la superficie del soporte (especificado en la ficha técnica de la imprimación). In the case of concrete surfaces, it will be necessary to allow a 28-day curation process after pouring. Otherwise, it will be necessary to check the maximum admissible humidity level on the underlayment service (specified in the product’s technical sheet). Choosing primer | Elección de la imprimación Application Aplicacion Action Required Acción requerida P& NP All | Todas PRIMER EPw-1070 TECNOFLOOR T-3020 P All | Todas PRIMER EP-1020 100% solids epoxy coating Revestimiento epoxi 100% solidos NP All | Todas PRIMER EPw-1070 TECNOFLOOR T-3020 AS P Self-Leveling | Autonivelante PRIMER EP-1020 Antistatic 100% solids coating Rev. 100% sólidos antiestático NP Self-Leveling | Autonivelante PRIMER EPw-1070 TECNOFLOOR Tw-3040 Water based epoxy coating Revestimiento epoxi base acuosa P: porous surface | soporte poroso NP: non porous surface | soporte no poroso 2 1 9 EPOXY FLOORS 3 A Painting Application | Aplicación como Pintura Upon completing the underlayment surface’s preparation process, and once the primer layer is dry (see technical sheet of the primer), using a roller or airless-like unit, proceed to apply as many TECNOFLOOR layers as you see fit, in accordance with the level of resistance you wish to achieve. Apply at least 2 layers of product, allowing a 24 h interval between them. For optimal finishing and in order to ensure an even surface spread and protection, apply layers perpendicularly to one another. 10 3 A Una vez preparado el soporte y con la imprimación seca (ver ficha técnica de la imprimación), se aplicará mediante rodillo o equipo tipo airless las capas necesarias de TECNOFLOOR en función de la resistencia deseada, siendo recomendable aplicar un mínimo de 2 capas con un intervalo de 24 h entre ellas. Para un acabado óptimo y conseguir que la superficie quede uniformemente cubierta y protegida, se recomienda que la aplicación de las distintas capas se haga de forma cruzada (perpendicular entre ellas). CONTINUOUS HEAVY DUTY FLOORING | PAVIMENTOS CONTINUOS DE ALTA RESISTENCIA 3 B Application as Multilayer | Aplicación como Multicapa Upon completing the underlayment surface’s preparation process, and once the primer layer is dry (see technical sheet of the primer), using a roller or airless-like unit, apply a first TECNOFLOOR layer. Una vez preparado el soporte y con la imprimación seca (ver ficha técnica de la imprimación), se aplicará mediante rodillo o equipo tipo airless una primera capa de TECNOFLOOR. Immediately afterwards, and while the product is still wet (very important), sprinkle a layer of aggregate until saturated. Inmediatamente después y con el producto húmedo (muy importante) se espolvoreará una capa de árido a saturación. Allow 24 hours and then sweep excess product, sandblast and, once again, sweep or vacuum surface to remove any leftover dust. A las 24 horas se barrerá el producto excedente, se lijará la superficie y se volverá a barrer / aspirar para retirar los restos del lijado. Apply a final TECNOFLOOR layer, covering the surface completely. Por último se aplicará una capa final de TECNOFLOOR para cubrir completamente la superficie. Repeat process as many times as required to achieve the desired strength. Estos pasos pueden repetirse tantas veces como sea necesario en función de la resistencia deseada. 11 3 B EPOXY FLOORS 3 C Application as Multilayer Plus | Aplicación como Multicapa Plus Upon completing the underlayment surface’s preparation process, and once the primer layer is dry (see technical sheet of the primer), using a roller or airless-like unit, apply a first TECNOFLOOR layer. While the product is still humid (very important), light sprinkle a layer of 0.3~1.3 aggregate and allow sufficient time for it to dry out. Once dry, sweep excess materials. Using a flat trowel, apply a new layer of TECNOFLOOR Tw-3040, this time mixed with aggregate 0.1 ~ 0.3 in proportion 1:1. While this last surface is still humid, light sprinkle another layer of 0.3~1.3 aggregate and let it dry out. 12 Once dry, sweep loose aggregate, and sandblast surface. Vacuum dust resulting from sandblasting operation. Using a squeegee, spread a layer of TECNOFLOOR diluted with 10% water. Steps in color can be repeated as many times as required, based on target thickness and resistance. 3 C Una vez preparado el soporte y con la imprimación seca (ver ficha técnica de la imprimación) se aplicará una primera capa de TECNOFLOOR. Con el producto aun húmedo se realizará un espolvoreado suave de árido 0,3 ~ 1,3 y se dejará secar. Una vez seco se barrerá el sobrante. Con una llana lisa se aplicará una nueva capa de TECNOFLOOR Tw-3040 que previamente se habrá mezclado con árido 0,1 ~ 0,3 en proporción 1:1. Con la capa anterior aun húmeda se realizará un nuevo espolvoreado suave de árido 0,3 ~ 1,3 y se dejará secar. Una vez seco se barrerá el árido no adherido, se lijará el resto y, finalmente, se aspirará el sobrante resultado del lijado. Por último se aplicará, con labio de goma, una capa de TECNOFLOOR diluido con un 10% de agua. Los pasos coloreados se pueden repetir tantas veces como sea quiera en función del espesor y la resistencia requeridos. CONTINUOUS HEAVY DUTY FLOORING | PAVIMENTOS CONTINUOS DE ALTA RESISTENCIA 3 D Self-Leveling Application | Aplicación como Autonivelante Upon completing the underlayment surface’s preparation process, and once the primer layer is dry (see technical sheet of the product), apply a TECNOFLOOR layer using a notched trowel. Make sure that layer thickness meets intended use requirements (recommended minimum thickness 2mm). It is essential to use a mechanical stirrer at low speed for mixing components A and B before use using, to prevent air bubble formation in the mixture, making sure to mix along the inner perimeter of the drum’s base thoroughly. Another possibility is to mix the product with 0.3 ~ 0.5 aggregate in 1:1 proportion and stir with mechanical stirrer at low speed. 20 minutes after applying TECNOFLOOR T-3020 it will be necessary to roll porcupine roller over surface to release trapped air. Outdoor Finishing: In outdoor applications, once the product is dry, apply a final layer of your TECNOTOPrange aliphatic enamel of choice. Anti-Slip Finishing: For Anti-Slip finishings, apply, once the product layer is dry, a final layer of our TECNOTOP range aliphatic enamel of choice mixed with a TECNOPLASTIC range micronized plastic (8% recommended). 3 D Una vez preparado el soporte y con la imprimación seca (ver ficha técnica de la imprimación) se aplicará mediante llana dentada (dientes triangulares) una capa de TECNOFLOOR con el espesor deseado (mínimo recomendado de 2mm.). Es muy importante que la mezcla previa de los componentes A y B se realice con agitador mecánico a bajas revoluciones para evitar aportar aire a la mezcla, insistiendo sobre todo en el perímetro interior de la base del bidón. Existe la posibilidad de mezclar el producto con un árido 0,3 ~ 0,5 en proporción 1:1 mezclando con el agitador mecánico a bajas revoluciones. Tras 20 minutos de la aplicación de TECNOFLOOR T-3020 es necesario pasar un rodillo de púas con el que facilitaremos la salida del aire ocluido. Acabado intemperie: en aplicaciones expuestas a la intemperie se aplicará, una vez seco el producto, una capa final de esmalte alifático de la gama TECNOTOP. Acabado antideslizante: para acabados antideslizante se aplicará, una vez seco el producto, una capa final de esmalte alifático de la gama TECNOTOP mezclado con plástico micronizado de la gama TECNOPLASTIC (8% homologado CTE SUA1). 13 EPOXY FLOORS Technical specifications|Características técnicas UNE-EN 1504.2 TECNOFLOOR Tw-3040 14 Density Densidad ± 1,3 g/cm3 Pot life at 23 ° C Pot life a 23 ºC ± 90’ ISO Viscosity nº 6 at 23 ° C Viscosidad ISO nº 6 a 23 ºC ± 1500 mPa.s Solids Contenido en sólidos ± 70% Recoat Time Tiempo de aplicación entre capas 12 ~ 24 hours Fully hardened past Totalmente endurecido pasados 7 days Shore D hardness 7 days Dureza Shore D a 7 días >75 Passable Transitable ± 24 hours Adhesion on concrete (UNE EN 1542:2000) Adherencia sobre hormigón (UNE EN 1542:2000) >2 MPa Surface temperature / environmental Temperatura del soporte/ambiental Min 8 ºC / Max 30 ºC Temperature Resistance Resistencia a la temperatura Min -20 ºC / Max 80 ºC Reaction to fire (UNE-EN 135011:2002) Comportamiento al fuego (EN 135011:2002) A2FLS1 Carbon dioxide permeability determination (UNE-EN 1062-6:2003) Determinación de la permeabilidad al dióxido de carbono (UNE-EN 1062-6:2003) SD > 50m Water vapor permeability determination. Capsule method (UNEEN ISO 7783:2012) Determinación de la permeabilidad al vapor de agua. Método de la cápsula (UNE-EN ISO 7783:2012) CLASE I: Sd < 5 m (permeable) Liquid water permeability determination Determinación de la permeabilidad al agua (UNE-EN 1062-3:2008) líquida (UNE-EN 1062-3:2008) w < 0,1 Kg/m2 X 0,5 R Determination abrasion resistance. TABER abrasion test apparatus (UNEEN ISO 5470-1:1959) Determinación de la resistencia a la abrasión. Aparato de ensayo de abrasión TABER (UNE-EN ISO 5470-1:1959) Mass loss = 262 mg Pérdida de masa = 262 mg Resistance against strong chemical aggression (UNE-EN 13529:2005) Resistencia a fuertes ataques químicos (UNE-EN 13529:2005) CLASE I : 3 days without pressure CLASE I : 3 días sin presión Quick buckling tests (resistance to impact). Drop weight test with large surface striker (UNE-EN-ISO 62721:2004) Ensayos de deformación rápida (resistencia al impacto). Ensayo de caída de una masa con percutor de gran superficie (UNE 62721:2004) Without cracks anf flaking. Mass of 1,000 g and 2,000 g. Sin fisuras ni escamado masa de 1.000 g y 2.000 g. Mass drop test (UNE-EN 1542:2000) Ensayo de caída de masa (UNE-EN 1542:2000) B > 1,5 CONTINUOUS HEAVY DUTY FLOORING | PAVIMENTOS CONTINUOS DE ALTA RESISTENCIA TECNOFLOOR T-3020 & TECNOFLOOR T-3020 AS Density Densidad 1,65 g/cm3 Pot life at 23 ° C Pot life a 23 ºC 40’ ISO Viscosity # 6 at 23 ° C Viscosidad ISO nº 6 a 23 ºC ± 800 mPa.s Recoat Time Tiempo de aplicación entre capas 12 ~ 48 hours Fully hardened past Totalmente endurecido pasados 7 days Shore D hardness 7 days Dureza Shore D a 7 días >80 Passable Transitable ± 24 horas Adhesion on 1542:2000) concrete (UNE EN Adherencia sobre 1542:2000) hormigón (UNE EN >2 MPa Surface temperature / environmental Temperatura del soporte/ambiental Min 8 ºC / Max 30 ºC Temperature Resistance Resistencia a la temperatura Min -20 ºC / Max 80 ºC Carbon dioxide permeability determination (UNE-EN 1062-6:2003) Determinación de la permeabilidad al dióxido de carbono (UNE-EN 1062-6:2003) SD < 50m Water vapor permeability determination. Capsule method (UNEEN ISO 7783:2012) Determinación de la permeabilidad al vapor de agua. Método de la cápsula (UNE-EN ISO 7783:2012) CLASE III Liquid water permeability determination Determinación de la permeabilidad al agua (UNE-EN 1062-3:2008) líquida (UNE-EN 1062-3:2008) w < 0,1 Kg/M2 X 0,5 R Determination abrasion resistance. TABER abrasion test apparatus (UNEEN ISO 5470-1:1959) Determinación de la resistencia a la abrasión. Aparato de ensayo de abrasión TABER (UNE-EN ISO 5470-1:1959) AR1 Resistance against strong chemical aggression (UNE-EN 13529:2005) Resistencia a fuertes ataques químicos (UNE-EN 13529:2005) CLASE I Quick buckling tests (resistance to impact). Drop weight test with large surface striker (UNE-EN-ISO 62721:2004) Ensayos de deformación rápida (resistencia al impacto). Ensayo de caída de una masa con percutor de gran superficie (UNE 62721:2004) IR > 4 Mass drop test (UNE-EN 1542:2000) Ensayo de caída de masa (UNE-EN 1542:2000) B > 1,5 15 Certified company: Memeber of: Distributed by / Distribuido por: TECNOPOL SISTEMAS, S.L. Pol. Ind. Z · c/Premsa, 5 CP: 08150 · Parets del Vallès · Barcelona (Spain) Telf. (+34) 93 568 21 11 · Fax. (+34) 93 568 02 11 e-mail: info@tecnopol.es · www.tecnopol.es @tecnopol_stms