espa architecture
Transcription
espa architecture
ISSN 1614-9572 BACnet Europe Journal BACnet – World of Integration Frankfurt/Main April 6.–11., 2008, Hall 9.1, Stand 08 03/08 BACnet am Flughafen Airport goes BACnet 9 Interview: Unabhängigkeit Interview: Independence 13 Herausforderung Energiesparen Saving Energy as Challenge 20 Kommandopriorisierung Command Priorization 45 BACnet beflügelt Export BACnet boosts Export 57 DESIGO TX-I/O All field devices under firm control. The innovative and streamlined DESIGO TX-I/O™ product range offers flexibility, user-friendliness and compact design. The DESIGO TX-I/O modules conform to DIN-standards, save space, are short-circuit-proof and eliminate false wiring. Moreover, they allow concrete cleartext labeling giving an overview over the connections. Only four types of I/O modules are required to handle all types of signals. Optional features include manual control, multicolor LEDs and LCD. The new DESIGO TX-I/O modules are fully compatible with the proven PTM modules, thus protecting the customers' investments. www.siemens.com/buildingtechnologies s Inhalt – Content Editorial Notes 5 Editorial: Steil bergauf zur Integration – Editorial: A Rapid Step towards Integration 6 BACnet – Welt der Integration – The World of Integration Erfahrungsbericht – Field Report 9 BACnet Europe Journal 13 Hohe Unabhängigkeit von Einzelfabrikaten BACnet Technology – System Integration with several manufacturers 17 BACnet senkt Kosten an der Universität Bremen BACnet cuts costs at the University of Bremen ISSN 1614-9572 The BACnet Europe Journal is the European magazine for building automation based on BACnet technology. Experts, practitioners and professionals show the way in applying and developing the BACnet standard – from building automation trends to devices and application projects; from qualification and training to testing and certification; from who’s who in the BACnet community to useful information on events and publications. Special attention is given to members and activities of the BACnet Interest Group Europe (BIG-EU). Flughafen Frankfurt plant Gebäudeautomation mit BACnet Frankfurt Airport goes BACnet for Building Automation Anwendungen – Solutions Distribution This bi-annual and bi-lingual Journal (English/German) can be ordered free of charge by partners, members, media representatives and friends of the BACnet Europe Interest Group (BIG-EU) - registered society. Order the BACnet Europe Journal by E-Mail from info@big-eu.org 20 Deutsche Post: Energiesparen beginnt mit BACnet German postal service: Saving Energy Starts with BACnet 22 Fit for Future – neue Gebäudeleittechnik an der Universität Stuttgart Future-proof Building Services Management System at university of Stuttgart 24 Gebäudeautomation XXL auf der Neuen Messe Stuttgart Neue Messe Stuttgart is Building Automation XXL 26 Effektive Integration hinter historischer Fassade – Effective Integration behind ancient Facade 28 Höchstmaß an Energieeffizienz – Highest Level of Energy Efficiency 30 Landschaftsverband Rheinland – Integration in bestehende GLT BACnet Integration in Existing System 34 DSM senkt Energiekosten mit BACnet Antrieben – DSM cuts Energy Costs with BACnet Drives 36 Energiesparende Klimatechnik in der Berliner Charité Energy-saving Air Conditioning Technology at the Charité Hospital Berlin 38 Maximale Funktionalität, totale Integration – Maximum functionality, total integration 41 Fraport testet BACnet Geräte – Wettbewerb auf hohem Niveau Airport test BACnet Devices – Competition at High Stage Editor BACnet Europe Interest Group (BIG-EU), registered society, Droste-Hülshoff-Straße 1 44141 Dortmund Germany Phone: +49-2 31-56 77 72 69 Fax: +49-2 31-42 78 67 32 E-mail: info@big-eu.org URL: www.big-eu.org 43 BACnet Test Framework an der FH Dortmund University of Applied Sciences and Arts Dortmund meets BACnet Test Framework 45 Kommandopriorisierung mit BACnet – Command Priorization with BACnet Executive Board Volker Röhl, DeTeImmobilien (President), Bill Swan, Alerton/Honeywell (Vicepresident) Gijs de Koning, Regel Partners B.V. Roger Braun, Siemens Schweiz AG (Treasurer) Online distribution The BACnet Europe Journal is posted as a Portable Document Format (PDF)-File to www.big-eu.org and www.bacnet.de Produkte – Products Editorial Office MarDirect Marketing Direct GbR Bruno Kloubert Phone: +49-2 31-42 78 67 31 E-mail: kloubert@mardirect.de Picture credits BIG-EU, MarDirect and specified companies BACnet® is a registered trademark of the American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc. (ASHRAE) BACnet/IP Building Controller frei programmierbar Freely programmable BACnet/IP Controller 47 Deltas Fenster in die BACnet Welt – Delta´s Window to the BACnet World 48 Natives BACnet mit der `Wonderware System Platform´ Native BACnet with the Wonderware System Platform 49 Objektorientiertes System für offene Lösungen – Object-oriented System for open Solutions 51 Neue BACnet Automationsstationen – New Automation Stations for BACnet 53 Universal-Gataway Compact: Der Schlüssel zur Integration The Key to Integration: Universal-Gataway Compact 54 Extrem flexibel und reich an Funktionen – Extremly Flexible and High in Performance 55 BACnet-Watcher funktioniert ohne GLT – Operates without BMS: BACnet-Watcher BACnet Interest Group Europe Advertising MarDirect Marketing Direct GbR Britta von Helden Phone: +49-2 31-56 77 72 69 Fax: +49-2 31-42 78 67 32 E-mail: vonhelden@mardirect.de Copyright © BIG-EU 2008 – Further editorial use of articles in the BACnet Europe Journal is encouraged (!) with reference to the source. Please send a specimen copy to the editor, or if published online, send the URL per mail to kloubert@mardirect.de 46 57 AHR Expo: BACnet beflügelt Export – AHR Expo: BACnet boosts export 58 Normungsausschuss – SSPC 135 Meeting 60 Willkommen in der BIG-EU – Welcome to the BIG-EU 61 Fachbuch „Enregieeffizienz durch Gebäudeautomation“ 62 BACnet Kalender – Calendar of BACnet Events ISSN 1614-9572 BACnet Europe Journal BACnet – World of Integration Frankfurt/Main April 6.-11., 2008, Hall 9.1, Stand B59 08 03/08 Titelbild Cover picture Flughafen Frankfurt Frankfurt Airport Alle Ausgaben sind als Download im Servicebereich von www.big-eu.org verfügbar All issues can be downloaded from the service area of www.big-eu.org BACnet am Flughafen À«ÀÌÊ}iÃÊ iÌÊÊÊÊ Interview: Unabhängigkeit ÌiÀÛiÜ\Ê`i«i`iViÊÊʣΠHerausforderung Energiesparen ->Û}ÊiÀ}ÞÊ>ÃÊ >i}iÊÊÊÓä Kommandopriorisierung >`Ê*ÀÀâ>ÌÊÊÊ{x BACnet beflügelt Export iÌÊLÃÌÃÊÝ«ÀÌÊÊÊxÇ © Fraport AG BACnet Europe Journal 8 03/08 3 Ideenreichtum für die Welt von morgen Damit aus einer Vision Wirklichkeit wird, muss man das Unmögliche behandeln, als wenn es möglich wäre. Wir von Johnson Controls arbeiten daran, das Leben lebenswerter zu gestalten und die Orte zu verbessern, an denen die Menschen ihre Zeit verbringen. Dafür optimieren unsere Spezialisten Prozesse und planen maßgeschneiderte Lösungen für Ihre Industrieanlagen und Gebäudesysteme. Von Lüftung, Klima und Kälte bis zur Sicherheits-, Steuer- und Regelungstechnik: wir haben für viele Anwendungen die passende technische Antwort – und die entscheidenden Ideen, damit aus Ihren Visionen Wirklichkeit wird. Für mehr Energieeffizienz, mehr Qualität und mehr Verlässlichkeit in Ihrem Betrieb. Wann sprechen wir über Ihre Ideen? JOHNSON CONTROLS SYSTEMS & SERVICE GMBH | TELEFON: 0621 / 468-601 | FAX: 0621 / 468-314 | WWW.JOHNSONCONTROLS.DE Steil bergauf zur Integration A Rapid Step towards Integration Liebe Leser, BACnet hat sich in kurzer Zeit zum Weltstandard für ein offenes Kommunikationsprotokoll in der Gebäudeautomation entwickelt. Dies war auf Grund der vorherrschenden proprietären Systeme nicht unbedingt zu erwarten. Aber nach der Gründung der BIG-EU vor zehn Jahren ging es zuerst in Deutschland und anschließend in Europa steil bergauf. Getrieben wurde dies von den zielgerichteten Kräften aus dem Bereich der Hersteller, Planer und Immobilienbetreiber in der BIG-EU. Damit wurde die nachhaltige Weiterentwicklung von BACnet zum Weltstandard massiv unterstützt. Durch die Reaktion der Hersteller auf einen sich positiv abzeichnenden „BACnet-Markt“ stehen dem Fachplaner heute (fast) alle Möglichkeiten der Integration gebäudetechnischer Anlagen, Funktionen und Informationen zur Verfügung. Die Ziele der Betreiber und Investoren können mit heute verfügbaren Mitteln erreicht, ja teilweise sogar übertroffen werden. Das setzt aber die richtige fachtechnische Beratung und Planung voraus. Dear Reader, BACnet has in a very short period of time developed into the worldwide standard open communication protocol within building automation. This was not really to be expected due to the presence of the dominant proprietary systems. After the foundation of the BIG-EU ten years ago Germany tookoff and was immediately followed by the rest of Europe. This rapid climb to success was driven by numerous goal-oriented forces within the BIG-EU from the areas of manufacturing, planning and real estate. For this reason the sustainable development of BACnet as a worldwide standard has been solidly supported. Today, due to the reaction of manufactures towards a positively defined BACnet market (nearly) every possible option for the integration of building technology applications, functions and information is available to planers. Today, the goals set by these companies and investors can be reached, if not even partially surpassed, with the resources readily available. This of course assumes correct specialist consulting and planning. Für einen wirtschaftlichen und nutzerorientierten Gebäudeoder Liegenschaftsbetrieb ist es unabdingbar, dass zur richtigen Zeit die richtigen Informationen zur Verfügung stehen. Damit erhebt sich automatisch die Forderung nach der zentralen Betriebsführung und Integration aller Systeme. Sie ist eine Vorrausetzung, um z. B. Forderungen zur Energiekostenoptimierung und -abrechnung zu erfüllen (s. Artikel „Neue Messe Stuttgart“ und „Fraport“). For profitable and user oriented building & real estate businesses it is essential that the right information is available at the right time. This automatically raises the need for a central control system and the integration of all systems. This is a requirement that, for example, meets both energy and service cost optimisations (see article “New Stuttgart Fair” and “Fraport”). Abgesehen von dem betriebsorientierten Mehrwert durch BACnet erschließt das offene Kommunikationsprotokoll die Möglichkeit des freien Wettbewerbs. Dadurch sind der Investitionsschutz gewahrt, der Einsatz innovativer, nutzungsgerechter Technik gesichert und marktgerechte Kosten erzielbar. Apart from service oriented added value enabled through BACnet, the open communication protocol unlocks the possibility for open competition. Therefore investments are protected, the application of innovate, technology which is right for the task is assured and, is obtainable in line with market costs. Das Engagement der AMEV Arbeitsgruppe „BACnet in öffentlichen Gebäuden 2007“ und die Weiterentwicklung des Standardleistungsbuchs StLB Bau (070) fördern diesen Prozess. Assisting this process is the involvement of the AMEV working group “BACnet in Public Buildings 2007” and the further development of the standard performance book StLB Building (070). Mit dem Weltstandard BACnet steht uns ein offenes Kommunikationsprotokoll für die Gebäudeautomation mit starker Marktdurchdringung zur Verfügung. Ich lade Sie ein, den Stand der BIG-EU auf der Light+Building zu besuchen und sich über die neuesten Entwicklungen, Systemintegrationen und die durchgeführte Zertifizierung zu informieren. BACnet, a world standard for building automation and an open communication protocol which has strong market penetration is now available. I would like to invite you to visit the BIG-EU stand at light+building where it will be able to inform you about the latest developments, system integration and how certification operates. Auf Wiedersehen auf der Light+Building! See you again at light+building! Siegfried Weikmann Planungsgruppe M+M AG Mitglied des BIG-EU Beirates Member of the BIG-EU Advisory Board BACnet Europe Journal 8 03/08 5 BACnet Interest Group Europe BACnet – Welt der Integration The World of Integration BACnet live auf der Light+Building: Die BACnet Interest Group Europe (BIG-EU) zeigt mit 30 Ausstellern aus sieben Nationen, wie BACnet in der Praxis funktioniert. Die ausgestellten Produkte sind miteinander vernetzt. Der Gemeinschaftsstand ist angelegt wie ein MultiVendor-Projekt, in dem alle Komponenten einheitlich mit dem BACnet Protokoll kommunizieren. BACnet live at light+building: the BACnet Interest Group Europe (BIG-EU), comprising of 30 exhibitors from seven countries, shows how BACnet functions in practice. The exhibited products are all networked with each other. The association’s stand, B59 in Hall 9.1, is a multi-vendor project in which all components consistently communicate using the BACnet protocol. Auf ihrem bisher größten Messestand präsentiert sich die BIG-EU mit dem Slogan „BACnet – Welt der Integration. 10 Jahre Erfolg in Europa“. Vor genau zehn Jahren wurde die BIG-EU von 18 Unternehmen gegründet. Seitdem hat sich der herstellerneutrale Integration mit BACnet zum Erfolgsfaktor in der Gebäudeautomation entwickelt. Heute zählt die BIG-EU 80 Mitglieder – und von Monat zu Monat werden es mehr. Herstellerneutrale Zone in der Mitte Auf der Light+Building ist die BIG-EU mit 30 Ausstellern aus sieben Nationen vertreten. Die BACnet Gemeinschaft auf der Messe ist damit so groß wie nie zuvor. Zu den Ausstellern zählen: ABB Automation Products, Alerton, Axima, Delta Controls, GFR, Honeywell, I.T.E.N.O.S., INGA, INH GmbH/HHO-Automation, Johnson Controls Systems & Service, Kieback&Peter, 90 80 70 60 50 40 30 20 10 0 1998 1999 2000 2001 2002 2003 2004 2005 2006 Mitgliederentwicklung der BIG-EU 1998-2008. BIG-EU Membership development 1998-2008. 6 BACnet Europe Journal 8 03/08 2007 2008 Frankfurt/Main April 6.–11.2008 hall 9.1, stand B59 MBS, Neuberger Gebäudeautomation, Novar, Plüth Regelsysteme, Priva, Promotor Verlag, Regel Partners, SaiaBurgess, Samson, SauterCumulus, SE-Elektronic, Siemens SBT, SysMik, TAC, Trane, WAGO Kontakttechnik, Wonderware und WSPLab. Neu ist die herstellerneutrale Zone in der Mitte des Stands. Hier zeigt die BIG-EU die Vorteile von BACnet bei der Integration. Erfahrene Integratoren erklären die übergreifende Kommunikation am Beispiel von Automations- (BACnet – Building Controller B-BC) und Managementstationen (BACnet Operator Workstations – B-OWS). Aus den über 48 Diensten, die BACnet bietet, wird die Architektur von BACnet Systemen an fünf Beispielen gezeigt: Alarme, Zeitpläne, Trends, Datenaustausch und Gerätemanagement. Neu auf dem Stand sind auch die weltweit ersten Geräte mit europäischem BACnet Zertifikat. Als europäischer Nachweis für geprüfte BACnet Konformität ergänzt das Zertifi kat die amerikanische BTL Marke. Die BIG-EU sieht darin die Basis, um europäische Anforderungen zur Energieeffi zienz und zur Zertifi zierung von Gebäudeautomationssystemen wirksam umzusetzen. Feierliche Übergabe Die feierliche Übergabe der Konformitätsnachweise fi ndet am 7. April um 14.30 Uhr auf der Messe statt. Die Zertifi kate werden von WSPCert, der europäischen BACnet Zertifizierungsstelle überreicht. Die Genehmigungen zum Führen der BTL Marke vergibt die BIG-EU. Von den amerikanischen BACnet Testing Laboratories (BTL) entwickelt, bleibt die BTL Marke weiterhin das internationale Zeichen für BACnet konforme Produkte. Alle Produkte mit BTL Marke werden öffentlich gelistet. Die BIG-EU führt ihre Liste unter www.big-eu.org/ conformance/listeu.php/, die Liste der amerikanischen BACnet International (BI) ist über www.bacnetinternational.org/btl/ erreichbar. Die Listings sind Marktübersichten zu allen geprüften Geräten. Sie enthalten detaillierte Informationen über die eingetragenen Produkte, vom technischen Datenblatt bis zu den ausführlichen Konformitätserklärungen (Protocol Implementation Conformance Statement – PICS). BACnet hat mit der AMEV Empfehlung „BACnet in öffentlichen Gebäuden 2007“ und mit der Weiterentwicklung des Standardleistungs- Willkommen zum BACnet Gemeinschaftsstand auf der light+building 2008. Welcome at the joint BACnet booth at the light+building. buchs (StBL) Bau 070 neue Impulse erhalten. Über alle laufenden Entwicklungen und die Mitgliedschaft in der BIG-EU können sich alle Besucher am BACnet Stand B59 in Halle 9.1 informieren. The BIG-EU is exhibiting under the banner “BACnet – the World of Integration - 10 Years of Success in Europe“ and has its biggest exhibition stand ever. The BIG-EU was founded by 18 companies exactly 10 years ago. Since then manufacturer neutral integration with BACnet has developed into a success factor in building automation. Today the BIG-EU has 80 members and its membership is steadily growing month by month. Exhibitors from Seven Countries The BIG-EU is represented by 30 exhibitors from seven countries at light+building. The BACnet community at the exhibition is therefore bigger than it ever has been before. The exhibitors include: ABB Automation Products, Alerton, Axima, Delta Controls, GFR, Honeywell, I.T.E.N.O.S., INGA, INH GmbH/HHO-Automation, Johnson Controls Systems & Service, Kieback&Peter, MBS, Neuberger Gebäude- automation, Novar, Plüth Regelsysteme, Priva, Promotor Verlag, Regel Partners, SaiaBurgess, Samson, SauterCumulus, SE-Elektronic, Siemens SBT, SysMik, TAC, Trane, WAGO Kontakttechnik, Wonderware, WSPLab. The manufacturer neutral zone in the middle of the stand is new. Here the BIG-EU shows how BACnet functions in integration. BACnet provides a total of 48 services. Experienced integrators explain the overlapping communication of alarms, schedules, data exchange, trends and equipment management by examples such as the automation workstation (BACnet-Building Controller (B-BC)) and the management workstation (BACnet Operator Workstation (BOWS)). Also new on the stand is the first appliance in the world to carry a European BACnet certificate. The certificate will be presented on April 7th at 2.30 p.m. at the BACnet booth by WSPCert, the European BACnet cer- tification centre. The grants to use the BTL mark will be presented by the BIG-EU. Tested BACnet Conformity The certificate is European proof of the tested BACnet conformity and complements the American BTL mark. The BIG-EU sees in this the basis for effectively implementing the European demands for energy efficiency and certification of building automation systems. The BTL mark developed by the BACnet Testing Laboratories (BTL) remains nevertheless the international uniform symbol for BACnet conforming products. All products with the BTL mark are publicly listed. The BIG-EU maintains its list on www.big-eu.org/conformance/listeu.php/, and the list of the American BACnet International (BI) can be reached on www.bacnetinternational.org/btl/. The listings are a market overview of all tested equipment. They contain detailed information about the listed products from technical data specifications to an extensive conformity declaration (Protocol Implementatio Conformance Statement – PICS). BACnet has received a new impulse from the AMEV recommendation “BACnet in Public Buildings 2007” and the further development of the standard instruction book StBL (070). Visitors to the BACnet stand can gain information about current developments and membership of the BIG-EU in Hall 9.1, Stand B59. Bruno Kloubert Head of Marketing MarDirect kloubert@mardirect.de BACnet Europe Journal 8 03/08 7 Wpo!ejftfn!Tuvim!sfhfmo!voe!tufvfso!Tjf!ejf!Xfmu 9Vh^hiYVh;Vho^c^ZgZcYZVc9ZaiV8dcigdahcVi^kZg768cZiHnhiZbVgX]^iZ`ijgÄH^Z`ccZckdc>]gZb 6gWZ^iheaViojcYkdcWZgVaab^iiZahLZWoj\g^[[Vj[VaaZ>]gZ<ZW~jYZ[jc`i^dcZcoj\gZ^[Zc!h^ZhiZjZgcjcY WZglVX]Zc#9^ZhZhKZghegZX]Zc\^ai[g=Z^ojc\!A[ijc\!@a^bV!7ZaZjX]ijc\hhiZjZgjc\!Ojig^iih`dcigdaaZ jcY6cW^cYjc\kdc:B6$7B6#DWH^ZZ^c-%"hiX`^\Zh=dX]]Vjh!Z^c`aZ^cZh7gd\ZW~jYZ!Z^c)%"<ZW~jYZ 8Vbejh!Z^cEgdYj`i^dchjciZgcZ]bZcdYZgZ^c*%%7ZiiZc@gVc`Zc]Vjhh^cY#B^iYZgaZ^X]iojWZY^ZcZcYZc BVcV\ZbZcihd[ilVgZ7"DLHDG86k^ZljcYDG86lZW]VWZcH^ZY^Z@dcigdaaZWZgY^Z>c[dgbVi^dcZc jcYc^X]iVcYZgh]Zgjb!]ZghiZaaZg"jcY\ZlZg`ZWZg\gZ^[ZcY#B^i9ZaiV8dcigdah^hi>ciZ\gVi^dcZ^c[VX]# lll#YZaiVXdcigdah#Xdb Erfahrungsbericht Field Report Flughafen Frankfurt plant Gebäudeautomation mit BACnet Frankfurt Airport goes BACnet for Building Automation Die Fraport AG als Flughafenbetreiber hat früh erkannt, dass die Gebäudeautomation mit ihren Einrichtungen für einen energieeffizienten, wirtschaftlichen und sicheren Betrieb der Technischen Gebäudeausrüstung sorgt und eine Voraussetzung für ein umfassendes Gebäudemanagement ist. The Fraport AG, the airport operator has detected early that the building automation with its equipment provides an energy efficient, economic and reliable operation and management of the technical building equipment and is a prerequisite for a comprehensive building management. Der Flughafen Frankfurt Main zählt zu den wichtigsten Weltflughäfen. Der Flughafenbetreiber Fraport AG beabsichtigt umfassende Sanierungs- und Modernisierungsmaßnahmen mit den Zielen: fenen Gebäudeautomationssystems (GA-System) der Bestand des kompletten Flughafengeländes wie der beiden Terminals, der Service- und Verwaltungsgebäude sowie der Bedarf zukünftiger Bauprojekte betrachtet. Ertüchtigung des technischen Anlagenbestandes, Beitrag zum Klimaschutz; Reduzierung des Energieverbrauches und der CO2 Emissionen, Neuorganisation und Sanierung der Gebäudeautomation auf Basis eines neutralen Kommunikationsprotokolls, Kostenreduzierung durch Wettbewerb und Produktneutralität, Einsatz moderner Gebäudemanagementstrategien, Entscheidung für BACnet Die Entscheidung für BACnet als offenes Datenkommunikationsprotokoll im Jahr 2003 war zukunftsweisend und geschah parallel zur weltweiten Standardisierung in der ISO 16484-5. Entsprechend diesen Zielen wird der Gebäudeautomation ein hoher Stellenwert beigemessen. Bereits zwei Jahre vor dem geplanten Start der Planungen hat die Fraport AG ein Expertenteam zusammengestellt, um die Vorgaben an ein gewünschtes heterogenes System, also ein System mit unterschiedlichen Herstellern, zu defi nieren. Der BACnet Standard als Teil der Weltnorm für Gebäudeautomation DIN EN ISO 16484 bietet das umfänglichste und leistungsfähigste Datenkommunikationsprotokoll in der Gebäudeautomation, das ohne Lizenzrechte und ohne herstellerspezifische Hardware für jedermann zugänglich ist. Hierbei wurde zur Realisierung eines wettbewerbsof- BACnet basiert auf genormten Diensten, Objekten und Funktionen und wird laufend im Standardisierungsgremium des SSPC 135 an neue Anforderungen agepasst und ergänzt. Lastenheft BACnet bietet innerhalb der Norm durch eine Vielzahl von optionalen Eigenschaften ge- wisse Gestaltungsfreiräume bei den Objekten sowie unterschiedliche Realisierungsmöglichkeiten bei der Umsetzung von Funktionen. Hinsichtlich der Anforderungen eines Großflughafens an die gewünschte und erforderliche Interoperabilität zwischen GA-Systemen unterschiedlicher Hersteller ist es unumgänglich, neben der Forderung nach Normkonformität diverse zusätzliche Festlegungen zu treffen. Die Fraport AG hat mit Unterstützung der GA Ingenieurgesellschaft mbH ein umfangreiches Lastenheft „Gebäudeautomation“ erstellt. Hier sind neben den Anforderungen an BACnet hinsichtlich der zu unterstützenden Dienste in den jeweiligen Interoperabilitätsbereichen (BIBBs) Objekte und deren Eigenschaften, Meldungsklassen, Alarmprioritäten, Quittierungsoptionen, Kommunikationsvorgaben etc. auch Anforderungen an die konventionellen Bereiche der Gebäudeautomation festgelegt worden. Es wurden Vorgaben an das Benutzeradress-System, die GA-Funktionen und spezielle übergeordnete Funktionen des Flughafens, die einzusetzende Hardware, Schaltanlagen und Installation, Netzwerke, Systeme für besondere Anwendungen, Bedien- und Managementeinrichtungen, die Raumautomation sowie die Dokumentation definiert. Darüber hinaus wurden im Lastenheft „Gebäudeautomation“ alle gewerkespezifischen Schnittstellen und Liefergrenzen beschrieben. GA-Planung mit BACnet Der Einsatz offener Kommunikationsprotokolle (hier: BACnet) und die Realisierung heterogener GA-Systeme stellt eine Herausforderung an die planenden Ingenieure im Bereich der Gebäudeautomation dar, bietet aber auch neue Möglichkeiten. Beispielhaft sei hier eine Auswahl unterschiedlicher Netzwerkstandards, die Freiheit bei der Strukturierung der Meldungsklassen, der Alarmierung und der Priorisierung genannt. Neben den grundlegenden Kenntnissen der Gebäudeautomation müssen die planenden Ingenieure über fundierte BACnet Kenntnisse verfügen, um dessen Vorzüge wirtschaftlich und funktionell umsetzen und ein interoperables Gesamtsystem planen zu können. BACnet Europe Journal 8 03/08 9 Erfahrungsbericht Field Report Offene Systeme sind in der Luftfahrt schon lange Realität. In the aerospace open systems are reality for a long time. Ein umfangreiches Studium der GA-Weltnorm DIN EN ISO 16484 ist für eine Planung der Gebäudeautomation mit BACnet unerlässlich, als Einstieg kann der BIG-EU „Leitfaden zur Ausschreibung interoperabler Gebäudeautomation auf Basis von BACnet“ benutzt werden. Darüber hinaus muss ein fundiertes Fachwissen im Bereich der von BACnet unterstützten Netzwerkstandards zur gebührenden Berücksichtigung der damit zusammenhängenden wirtschaftlichen, organisatorischen und technischen Aspekte vorausgesetzt werden. Wie können nun die erforderlichen BACnet-Spezifikationen und die Umsetzung der Anforderungen eines Großprojektes sinnvollerweise planerisch erfasst und dargestellt werden? Hierzu ist der konsequente Einsatz der VDI-Richtlinie 3814 Blatt 1 bzw. der DIN EN ISO 16484-3 ein Muss! Mit Hilfe der Automationsschemen und der dazu korrespondierenden GA-Funktionslisten muss der planende Ingenieur alle projektspezifischen Anforderungen an sämtliche (Ein-/Ausgabe-, Verarbeitungs-,Managementund Bedien-) Funktionen mit Zuordnung der zu verwen- denden BACnet-Objekttypen in der Bemerkungsspalte spezifizieren. Der Forderung der DIN 18386 (VOB/C: ATV Gebäudeautomation) zur Verwendung von Funktionen als Abrechnungseinheiten wird hiermit ebenfalls entsprochen und es werden einheitliche kalkulierbare Dienstleistungspositionen erzeugt. Umsetzung der geforderten Funktionalität durch unterschiedliche Auftragnehmer zu gewährleisten. Aus Sicht der Integrationsplanung wird empfohlen, sämtliche Datenpunkte eines Aggregates sowie alle Datenpunkte mit einer eigenen Benutzeradresse in einer separaten Zeile der GA Funktionsliste darzustellen. Erst damit besteht die Möglichkeit, sämtliche zugehörigen Funktionen eindeutig zu beschreiben. Darüber hinaus müssen zusätzliche, ergänzende bzw. nicht zur Norm gehörende Funktionen datenpunktbezogen, zeilenweise in der Bemerkungsspalte und ggf. auf Beiblättern erläutert werden. Zur Erstellung der Leistungsverzeichnisse sollten bei öffentlichen Ausschreibungen die Leistungspositionen mit Hilfe des Standardleistungsbuches 070 (zurzeit erfolgt eine Anpassung auf die BACnet-Spezifikationen) verwendet werden. Für die Darstellung komplexer Steuerungsabläufe empfiehlt sich die Verwendung von Zustandsgraphen bzw. Ablaufdiagrammen gemäß der neuen VDI-Richtlinie 3814 Blatt 6. Bei der Fraport AG wurden bereits im Vorfeld dieser Richtlinie umfangreiche Ablaufdiagramme erstellt, um eine einheitliche Auf dieser Basis und mit einem konsequenten Einsatz einer Qualitätssicherung in allen Planungs- und Ausführungsphasen kann der Umsetzung der durch die Fraport AG selbst gesetzten Ziele bei einem der weltweit größten BACnet-Projekte optimistisch entgegengesehen werden. 10 BACnet Europe Journal 8 03/08 Bei der Integrationsplanung ist die demnächst erscheinende VDI-Richtlinie 3814 Blatt 5 – „Hinweise zur Systemintegration“ zu berücksichtigen. Mit dem Einsatz von qualifi zierten GA-Fachingenieuren in der Planung und bei Einhaltung dieser Empfehlungen wird den potentiellen Auftragnehmern eine nachvollziehbare und kalkulierbare Ausschreibungsunterlage zur Verfügung gestellt. Frankfurt Airport (FRA) is one of the world‘s most important international airports. The airport operator Fraport AG intends comprehensive renovation and modernization activities with the objectives: Upgrading of technical equipment stocks, Contribution to climate protection; reduction of energy consumption and CO2 emissions, Reorganization and renovation of the building automation in view of the future airport requirements, Cost reduction by competition and product neutrality, Use of modern building management strategies In accordance with these objectives, a great importance will be attached to the building automation. Just two years before the scheduled start of the planning, Fraport AG has assembled a team of experts to define the requirements of a desired heterogeneous system, which is a system with different manufacturers. The stock of the complete airport ground as the two terminals, the service and administrative buildings and the needs of future building projects were considered, to realize a competitive building Erfahrungsbericht Field Report automation and systems (BACS). control Decision for BACnet The decision for an open BACnet data communication protocol in 2003 was pioneering and happened parallel to the global standardization in the ISO 16484-5. BACnet is based on standardized services, objects and functions and is constantly adjusted and supplemented in the SSPC 135 standardization committee to new requirements. The BACnet standard as part of the global standard for building automation and control systems DIN EN ISO 16484 offers the most extensive and powerful communications protocol for building automation and control systems, without the license rights and without the need for specific vendor hardware. System requirements Within the standard BACnet offers by a number of optional properties some creative leeway with the objects and different implementation possibilities for the implementation of functions. It is essential, that in addition to a demand for standard conformity, several additional specifications, with regard to the requirements of a major airport to the desired and required interoperability between BAC-Systems from different manufacturers, are to be taken. Fraport AG has created with the support of the GA Ingenieurgesellschaft mbH an extensive requirement of building automation. Here, in addition to the requirements of BACnet in terms of support services in their respective areas of interoperability (BIBBs), objects and their properties, notification classes, alarm priorities, acknowledge options, communications, etc. also set requirements on the conventional areas of building automation. A user-address system, the BACS functions and the overall special functions of the airport, the type of hardware, switchgear and installation, networks, dedicated special systems, operating and management devices, room control and documentation are specified there too. In addition, the system requirement contains all interfaces between all maintenance groups and building automation and delivery boundaries. Building automation planning with BACnet The use of open communication protocols (here: BACnet) and the implementation of heterogeneous BAC-Systems represent not only a challenge to the building automation planners, but also offer new possibilities. A selection of different network standards, alarm notifications, priorities and a structural freedom of notification classes may serve here as an example. Apart from the basic knowledge of building automation, the planning engineers must have a competent knowledge of BACnet to plan its benefits economically and functionally and implement an interoperable system. An extensive study of building automation world standard DIN EN ISO 16484 is essential for planning building automation with BACnet, as entry may be used the BIG-EU “guide to specifying interoperable building automation and control systems using BACnet”. In addition, a substantial exper- tise in the field of BACnet supported network standards for due consideration of the associated economic, organizational and technical aspects will be provided. How can this necessary BACnet specifications and the implementation of the requirements of a major project be usefully collected and displayed? For this the consistent use of the VDI guideline 3814 part 1 respectively DIN EN ISO 16484-3 is a must! With the help of automation schematics and the corresponding BACS function lists, the planning engineer has to specify all project requirements for all (I-/O, processing-, management- and operator-) functions with an assignment to used BACnet object types in the remarks column. The demands of DIN 18386 (VOB / C: Building Automation ATV) for use of functions as accounting units, are also satisfied and there will be uniform predictable service positions. From the integration planning is recommended that all data points of a unit and all data points with a unique user address are displayed in a separate row in the BACS function list. Only thus it is possible, to clear all functions related to describe. Moreover, additional, complementary and no-standard functions based on each data point should be remarked line by line in the remarks column, and possibly explained on additional sheets. It is recommended to use state graphs and flow charts according to the new VDI guideline 3814 part 6, for a planning and presentation of complex control circuits. These flow charts have been already created by Fraport AG in order to uniform implementation of the required functionality contractors. by different The forthcoming new VDI guideline 3814, part 5 – “References of systems integration” shall be used for integration planning. The German master specification for tender 070 which is currently revised on the BACnet specifications shall be used for establishing of performance lists for public tenders procedures. An assignment of qualified BACS engineers in a planning procedure and compliance with these recommendations provides potential contractors with an understandable and predictable tender document. On this basis and with a consistent use of quality assurance in all planning and implementation phases of the implementation, Fraport AG may optimisticly look forward to realization own targets in one of the major BACnet projects worldwide. Bernd Hanke Head of Airport Facility Management Fraport AG Günter Meyer Head of Engineering Planning and Project Management Fraport AG Thomas Kohlhoff Marius Hartel Managing Partner GA Ingenieurgesellschaft mbH info@ga-ing.de www.ga-ing.de BACnet Europe Journal 8 03/08 11 12 BACnet Europe Journal 8 03/08 Erfahrungsbericht Field Report Hohe Unabhängigkeit von Einzelfabrikaten BACnet Technology - System Integration with several manufacturers Die Wöhler Holding GmbH & Co. KG hat für ihr Unternehmen, die Wöhler Messgeräte Kehrgeräte GmbH in Bad Wünnenberg, einen Neubau errichtet – auf 5000 m2 und mit höchsten Anforderungen an die Energieeffizienz, Sicherheit und Bedienung. Bei der Systemintegration mit diversen Herstellern zeigt sich BACnet als marktfähiger Kompromiss aus Funktionalität und Wirtschaftlichkeit. Wöhler Holding GmbH & Co.KG constructed the new building of Wöhler Messgeräte Kehrgeräte GmbH - at 5000 square meters footage and according to the highest standards of energy efficiency, safety, and operating. The BACnet driven system integration of several building services is a compromise of functionality and economic efficiency. Die innovativen technischen Gebäudesysteme sollten durchgängig mit BACnet realisiert werden. Der Planungsauftrag ging an das Ingenieurbüro Ottensmeier in Paderborn. Dessen Aufgabe war eine besonders energieeffi ziente Planung der technischen Gebäudeausstattung (TGA). Welche Gründe haben zur Entscheidung für BACnet geführt? Das fragten wir die Verantwortlichen: Thomas Wecker, Produktionsleiter Wöhler, Franz-Gerd Stuckmann, Geschäftsführer des BIG-EU Mitglieds SWG Stuckmann Wirtschaftliche Gebäudesysteme GmbH, Claus-Hermann Ottensmeier, Projektleiter der Ottensmeier Ingenieure und Arend Brink, Leiter Produktmanagement des Systemanbieters Kampmann GmbH. BACnet Europe Journal: Herr Wecker, was veranlasste Wöhler, das BACnet-Protokoll als Grundlage der MSRRegelungstechnik zu wählen? Thomas Wecker: Um die MSR-Technik zu planen, haben wir zunächst ein Grundsatzgespräch mit der Ottensmeier Ingenieurgruppe und ponenten. Wie konnten Sie das Projekt realisieren? Systembeteiligte (v.l.n.r.) Involved partners (from left to right) Franz-Gerd Stuckmann, SWG · Claus-Hermann Ottensmeier, OI · Thomas Wecker, Wöhler · Arend Brink, Kampmann. der SWG geführt. Einerseits mussten die gegebenen Systeme im Altbau berücksichtigt werden. Andererseits hatten wir komplexe Anforderungen an die neue Gebäudetechnik. Wir wollten nicht nur Lüftungs-, Kessel- und Zugangskontrollsysteme integrieren, sondern auch eine Einzelraumregelung für die Be- und Entlüftung sowie ein Lichtsteuerungssystem. Dafür war ein übergeordnetes Protokoll zu finden, das alle Informationen auf eine Bedienoberflä- che bringt. Das BACnet Protokoll erfüllt diese Anforderung. Den Planern von Ottensmeier gaben wir den Auftrag, die einzelnen Komponenten unter einer einheitlichen Regelstruktur zu integrieren. BACnet Europe Journal: Herr Ottensmeier, die zentrale Aufschaltung auf ein übergeordnetes Gebäudeleitsystem stellt besondere Anforderungen and die Kom- Claus-Hermann Ottensmeier: Wöhler hat sich für eine investitionssichere Integration entschieden. Das Ziel ist ein offenes, zukunftsfähiges Gebäudeleitsystem, das fabrikatsneutral eine Anbindung von Einzelkomponenten aus den verschiedenen TGA-Gewerken ermöglichte. Das Stichwort heißt Interoperabilität. Mit BACnet können die ausgewählten Systeme gemeinsame Funktionen ausführen und managen. Wichtig war, dass die direkte BACnet-Anbindung gegeben war. Diese konnte durch die Fa. Kampmann mit dem Frischluft-Klimagerät und durch SWG mit der MSRTechnik von Delta Controls realisiert werden. Auch das Zugangskontrollsystem und die Volumenstromregelung von Delta Controls haben eine direkte BACnet-Anbindung. Für weitere Einheiten wie die Kesselanlage von Viessmann wurde eine LON-BACnetKopplung realisiert. Ebenso für das im Gebäude integrierte Bus-System LCN, und zwar über ein externes Modul zum BACnet-Bus. BACnet Europe Journal 8 03/08 13 Erfahrungsbericht Field Report BACnet Europe Journal: Herr Stuckmann, welche Kriterien waren für Sie als Systemintegrator bei der Systemauswahl entscheidend? Franz-Gerd Stuckmann: Der Anspruch an die Homogenität des Automationssystems war groß. Um sowohl das Bestandssystem anzubinden als auch die Zutrittskontrolle, Alarmüberwachung und Beleuchtungssteuerung sowie Einzelraumregelung zu integrieren, haben wir uns für ein System von Delta Controls entschieden. Das hat zwei Vorteile: Erstens ist hier ein einheitliches System von der BACnet-Operator-Workstation bis zur Feldebene mit Einbindung der Volumenstromregler und Frequenzumformer über BACnet vorhanden. Zweitens ermöglichte der innovative modulare Aufbau die notwendige Installation durch ortsansässige Unternehmen. favorisierten Lüftungsgeräte einzusetzen. Diese sollten nach dem Prinzip Frischluft-Klima mit indirekter Verdunstungskühlung funktionieren. Das Automationssystem ist direkt über TCP/IP eingebunden. BACnet Europe Journal: Herr Wecker, mit dem neuen Gebäude haben Sie Ihre Gebäudeautomation vollständig integriert. Wurden Ihre Ziele erfüllt? Thomas Wecker: Die Entscheidung für BACnet war sehr wichtig für unser Unternehmen. Nun können wir von jedem Ort und jedem Rechner die Anlagen einfach bedienen und überwachen. Über die einheitliche Bedienoberfläche überwachen, optimieren und analysieren wir den Betrieb. Das reduziert zum Beispiel unseren Energieeinsatz. Außerdem können wir durch das integrierte Stö- rungs- und Alarmmanagement jederzeit auf allen Ebenen eingreifen. Das ist für uns – zusammen mit der Zutrittskontrolle – ein enormer Zugewinn an Sicherheit. BACnet Europe Journal: Wir danken Ihnen für das Interview. Wöhler Holding GmbH & Co.KG constructed the new Building of Wöhler Messgeräte Kehrgeräte GmbH according to energy efficiency specifications. The building had to meet the highest energy efficiency and security standards. BACnet compromise in functionality and economical efficiency is very important for system integration with several manufacturers. The technical building system should be implemented via BACnet Technology. Wöhler assigned the engineers of Ot- tensmeier to plan the energy efficient building. We asked the project participants, Thomas Wecker, Plant Manager Wöhler; Franz-Gerd Stuckmann, CEO SWG GmbH (Member of BIG-EU); ClausHermann Ottensmeier, Project Manager Ottensmeier Ingenieure; Arend Brink, Project Manager, Kampmann GmbH, why they decided to connect the building automation via BACnet. BACnet Europe Journal: Mr. Wecker, why did you choose BACnet as the basis for the Building Automation & Control system? Thomas Wecker: We arranged an initial meeting with the engineers of Ottensmeier (OI) and SWG Stuckmann Wirtschaftliche Gebäudesysteme GmbH (SWG), to plan the Building technology. We had to consider the existing system in the old building on the one BACnet Europe Journal: Herr Brink, was bewog Sie als Hersteller, Automationssysteme mit BACnet Kommunikation einzusetzen? Arend Brink: Nach Jahren der Entwicklung und diversen Gehversuchen mit verschiedenen Standards bot BACnet erstmals eine Philosophie, die auf einem marktfähigen Kompromiss aus Funktionalität und Wirtschaftlichkeit beruht. Die hohe Unabhängigkeit von Einzelfabrikaten ist ein weiterer wichtiger Grund, sich für BACnet zu entscheiden. So war es mit dem Automationssystem EMS 4 der GFR (Gesellschaft für Regelungstechnik und Energieeinsparung mbH) möglich, die Integration diverser Hersteller-Systeme an die BACnet Technologie. Intergration of several manufacturers systems to BACnet technology. 14 BACnet Europe Journal 8 03/08 Erfahrungsbericht Field Report Projektpartner Project partner Bauherr Owner Wöhler Holding GmbH & Co. KG www.woehler.de Planer TGA Planning building services Ottensmeier Ingenieure www.oi-tga.de Systemintegrator System integrator SWG Stuckmann Wirtschaftliche Gebäudesysteme GmbH www.swg-beckum.de Neubau der Wöhler Messgeräte Kehrgeräte. New building of Wöhler Messgeräte Kehrgeräte. hand and on the other hand the extensive requirements towards our new building technology. We wanted to have a technology with the capability to integrate a HVAC unit, Access Control and a Light Control system with a single user interface. The BACnet protocol met all our requirements. Therefore Ottenmeier Ingenieure assigned the task to integrate all demanding components into one Building control structure. BACnet Europe Journal: Mr. Ottensmeier, how did you integrate the different components into the project? Claus-Hermann Ottensmeier: Wöhler requested a futureorientated automation system with the capacity to connect manufacturers’ individual components. BACnet’s interoperability enabled us to connect the different Systems, like the HVAC Unit from Kampmann, the Delta Controls System (SWG), a volume flow control and an access control system directly through the protocol. To connect additional units, such as the boiler from Viessmann, we linked them through LON to BACnet. BACnet Europe Journal: Mr. Stuckmann, which criteria were the decisive factors in determine and selecting the system? Franz-Gerd Stuckmann: Wöhler had high expectations in building a homogeneous automation system. The Delta Controls System enabled us to integrate the individual building control units (e.g. BACnet-Operator-Workstation, Volume flow control) to their existing system. The innovative structure of the system enables local contractors to do necessary installations. BACnet Europe Journal: Mr. Brink, as a manufacturer, what was your motivation to use the BACnet technology? Arend Brink: After spending years in developing different standards, BACnet is finally offering a philosophy that is based on functionality and cost effectiveness. An important reason why we decided to use BACnet is its ability to integrate different manufacturer products into one system. As a result we were able to connect the preferred HVAC units as well as GFR´s (Gesellschaft für Regelungstechnik und Energieeinsparung GmbH) automation system EMS 4 directly through TCP/IP. MSR/DDC BACnet AC Unit Delta Controls www.deltacontrols.de Lüftungsgeräte Airconditioning devices Kampmann GmbH www.kampmann.de BACnet Europe Journal: Mr. Wecker, did you reach your goals by implementing the new building control system? Kessel Boiler unit Viessmann Werke GmbH & Co KG www.viessmann.de Thomas Wecker: The decision pro-BACnet was very important for our company. The system allows the user to connect and manage it independently from any location. By using BACnet we were able to reduce our energy costs, by controlling, optimizing and analyzing our building through one interface. Furthermore, we are able to connect directly to our security and alarm level, in case of emergency. This ensures our requirements towards access control and alarm security. Frequenzumformer Frequency converter Danfoss GmbH www.danfoss.de BACnet Europe Journal: Thank you for your time. LON-BACnet Kopplung LON-BACnet Coupling Loytec electronics GmbH www.loytec.de LCN-BACnet Kopplung LCN-BACnet Coupling MBS www.mbs-software.de Bus-System Elektro Bus-System for electric systems LCN www.lcn.de BACnet Europe Journal 8 03/08 15 Your building’s energy costs have a direct impact on the environment in your boardroom. And on the planet. What’s good for business is good for society. Turn to TAC for intergrated building systems that cut energy usage. Meet TAC at Light & Building in hall 9.1, booth E50 and learn more. Copyright © 2008, TAC, a company of Schneider Electric. Erfahrungsbericht Field Report BACnet senkt Kosten an der Universität Bremen BACnet cuts costs at the University of Bremen Die Universität Bremen verwendete beim Ausbau ihrer Gebäudeautomation die Automationsstation Cosmos 4000 Open von Plüth. Über die neutrale BACnet Schnittstelle kommuniziert sie mit der Gebäudeleittechnik M-Plus von Johnson Controls. Schon in der Planungsphase konnte Plüth alle vom Betreiber geforderten Funktionen testen – dank des Simulationsmodells. Damit war der reibungslose Ablauf des Projekts garantiert. To upgrade its building automation the University of Bremen used the automation station Cosmos 4000 Open by Plueth, which communicates with the Johnson Controls central building control system via a neutral BACnet interface. As early as during the planning stages a simulation model allowed Plueth to test all the functions required by the operator, so smooth processing of the project was guaranteed. Die Universität Bremen ist das Wissenschaftszentrum im Nordwesten Deutschlands. Die Forschungsstätte für 1.950 Wissenschaftlerinnen und Wissenschaftler bietet Studienplätze für ca. 22.800 Studierende und weitere 1.250 Arbeitsplätze für nichtwissenschaftliche Mitarbeiter. Der reibungslose Betrieb des ständig wachsenden Gebäudebestands kann nur durch eine entsprechende Infrastruktur mit der dazugehörigen Gebäudeautomation gewährleistet werden. Dafür ist es notwendig, dass Anlagen und Anlagenteile 24 Stunden pro Tag an 365 Tagen im Jahr fehlerfrei funktionieren. Die BACnet Funktionalität wird daher vor Beginn der eigentlichen Baumaßnahme mittels Netzwerkanalyser überprüft. Die für die Betreiber wesentlichen Funktionen werden hierbei mittels Simulationsmodell eingehend untersucht. Alle Funktionen zwischen der Gebäudeleittechnik M-Plus von Johnson Controls und der Plüth Cosmos 4000 Open wurden getestet, die vom Betreiber geforderten Funktionen realisiert. Der Netzwerkanalyser macht den Datenverkehr transparent. BACnet Funktionalität vorgeschrieben Von der Gesellschaft für Bremer Immobilien wurde gemeinsam mit dem Ingenieurbüro m+p aus Braunschweig ein Konzept für eine neutrale Managementebene erarbeitet. Durch BACnet wurde eine wesentliche Verbesserung der Wettbewerbssituation in der Gebäudeautomation geschaffen. Der Erfolg lässt sich an den gesunkenen Investitionskosten ablesen. Für die Neubaumaßnahmen wurde ein Pfl ichtenheft entwickelt, dass die BACnetFunktionalität ab der Automationsstation vorschreibt. Neue dezentrale Bedienplätze sollten ebenfalls über BACnet kommunizieren und gleichzeitig so konzipiert sein, dass die Anlagen beim Ausfall der GLT autark sind. Da die Gebäudeautomation der Universität über ein eigenes Ethernet-Netzwerk betrieben © Universität Bremen Universität Bremen. University of Bremen. wird, ist die Bedienung der Anlagen mittels Webbrowser möglich. Volle Funktionalität und einheitliche Bedienung Die vorhandene Siemens Siclimat X- GLT mit ihren 5.000 Datenpunkten wurde über eine OPC- Schnittstelle in das Gesamtsystem eingebunden. Auf diese Weise lässt sich der gesamte Anlagenbestand über ein einziges Managementsystem überwachen und bedienen. Die Vorteile der neuen Systemstruktur mit BACnet liegen auf der Hand: Einfache Handhabung über Web-Browser, Volle Funktionalität und BACnet Europe Journal 8 03/08 17 Erfahrungsbericht Field Report Bedienung via „WEB“ Siemens Siclimat X-Terminal einheitliche Bedienung zentral oder dezentral, Abnahmen vor Ort über einen transportablen Laptop. JCI M5 plus mit Schnittstellen für: E 0 -S D C -B u s N 1 -M e ta sys-B u s B A C n e t-C lien t O P C -C lien t In trane t N etzw erk der U ni B rem en G läserne W arte m it „W E B -B row ser“ GLT-EZ GLT-EZ V T 1 00 E0 S iclim a t X S e rve r V e rsion V 4 N1 Zukünftige Maßnahmen Alarmierung via OPC S 5_L in k S5 P rofibus D ez. B edienplätze A utom ationsebene Die neue GLT-Systemstruktur an der Universität Bremen. New BMS System architecture at the University of Bremen. E nergiezentrale S iem ens O P C -S erver B eliebiger B edienp latz m it „W E B -B row ser“ NCM G-GLT G-GLT S5 NMT IW S /G W S SMT TZI, NAE B A C net/IP NCM ZIK, Plüth B A C net/IP An zentraler Stelle plant die Universität Bremen nun eine gläserne Leitstation. Durch das moderne Gebäudemanagementsystem und Plüth Cosmos 4000 Open sind dafür die besten Voraussetzungen geschaffen. tion work started. The most important functions for the operator are analyzed indepth using a simulation model. All functions between the Johnson Controls central building control system M-Plus and the Plueth Cosmos 4000 Open are tested and the functions required by the operator realized. The network analyzer makes the data communication transparent. from the automation station. New decentralized operator stations should also communicate via BACnet and at the same time be designed so that, in the event of a failure of the building management system, the other systems can continue independently. Since the university building automation runs via its own Ethernet network the systems can be operated via a web browser. The University of Bremen is the scientific hub of North West Germany. The research facility for 1,950 scientists has some 22,800 students and an administrative and technical staff of 1,250. The smooth operation of the ever increasing complex of buildings can only be warranted with the right infrastructure and the corresponding building automation. This means that all systems and system parts have to function properly 24/7. BACnet functionality specified A joint project between the Gesellschaft für Bremer Immobilien (responsible for properties belonging to the City of Bremen) and the Braunschweig engineering consultants m+p provided a concept for a neutral management level. BACnet has been able to establish a major improvement in the competitive building automation environment and successes of which can be seen in lower investment costs. Full functionality and standardized operation An OPC interface integrated the existing Siemens Siclimat X- GLT with its 5,000 data points into the complete system, allowing the entire system to be monitored and operated via a single management system. Therefore a network analyzer was used to check BACnet functionality before construc- Specifications were drawn-up for new developments stipulating BACnet functionality 18 BACnet Europe Journal 8 03/08 NAE The University of Bremen is now planning a transparent master control station and, with the modern building management system and Plueth Cosmos 4000 Open, the best foundations have been laid for this. The advantages of the new system structure with BACnet are obvious: Easy handling with a web browser, Complete functionality and standardized centralized or decentralized operation, On-site approval possible via laptop. Bernd Hoopmann m+p consulting Nord GmbH bernd.hoopmann@ mp-gruppe.de www.mp-gruppe.de ABB standard drives for HVAC applications – fluent in native BACnet plus 16 other languages Frequenzumrichter für die Gebäudetechnik – beherrschen fließend BACnet und 16 weitere Sprachen ABB standard drives for HVAC applications. 5000 BACnet installations worldwide. 8000 HKL-Frequenzumrichter von ABB. 5000 BACnet Installationen weltweit. 8000 Here’s why ABB standard drives for HVAC applications Das sind die Gründe, warum HKL-Frequenzumrichter von ABB wirklich really make a difference: den Unterschied machen: • Suitable for standard induction motors rated • Für Standard-Asynchronmotoren mit einer Nennleistung von from 0,75 to 355 kW (1 to 550 HP) 0,75 bis 355 kW (1 bis 550 HP) geeignet • Native BACnet embedded as standard • BACnet standardmäßig integriert • Direct connection to BACnet MS/TP networks – • Direkte Ankopplung an BACnet MS/TP-Netzwerke - kein Gateway no gateway needed notwendig • BTL approved B-ASC (Application Specific Controller) • BTL-Zulassung B-ASC (Application Specific Controller) Visit us at www.abb.com/drives Besuchen Sie uns im Internet unter www.abb.de/motors&drives E-Mail: motors.drives@de.abb.com Anwendungen Solutions Deutsche Post: Energiesparen beginnt mit BACnet German postal service: Saving Energy Starts with BACnet Energiesparen zählt seit Jahrzehnten zu einem der wichtigsten Mittel zur langfristigen Kostenminimierung – eine Binsenweisheit, die jedoch auch eine extreme Herausforderung bedeuten kann. Wie groß, das beweist ein Blick in die Fracht- und Briefzentren bei der Deutsche Post AG. Saving energy has been among the most important measures for long term cost minimization. This commonplace can represent quite a challenge, however. Its real size can be illustrated by a glance at the freight and letter centres of the Deutsche Post AG. Die Deutsche Post Immobilienservice GmbH ist eine Konzerntochter der Deutsche Post AG und einer der größten Immobilienbesitzer Deutschlands. Sie verwaltet ca. 8.600 Liegenschaften, und zwar nicht nur Büround Verwaltungsgebäude, sondern auch zahlreiche Fracht- und Briefzentren. Diese Fracht- und Briefzentren stellen enorme Energieverbraucher dar. Stehen zum Beispiel die Rolltore bei niedrigen Temperaturen zu lange offen, so zieht dies einen massiv erhöhten Energiebedarf zum Erreichen der voreingestellten Raumtemperatur nach sich. Zählerstände in Echtzeit In der Vergangenheit konnte DPIS Zählerstände der einzelnen Liegenschaften lediglich manuell erfassen und ausschließlich rückschauende Analysen anhand der Versorgungsabrechnung vornehmen – ein umständliches und zudem recht ungenaues Vorgehen. Ziel war es daher, möglichst bald ein System zu testen und einzuführen, welches zeitnah die Zählerstände der Energiezähler zentral verfügbar macht und weitere Maßnahmen zur Energieeinsparung auf effiziente Art unterstützt. Umgebung gehostet, zugänglich per normalem WebBrowser. Dank BACnet erlaubt activeOperation die zentrale Überwachung und Steuerung dezentraler Anlagen verschiedenster Hersteller mit unterschiedlichsten Applikationen. DPIS entschied sich für das Produkt activeOperation der I.T.E.N.O.S. GmbH, Bonn, nicht zuletzt weil mit BACnet die Forderung nach einer standardisierten Kommunikationsschnittstelle erfüllt war. Voraussetzung bei DPIS war die Aus- bzw. Nachrüstung aller Standorte mit elektronisch lesbaren Zählern und busfähigen Temperatursensoren, deren Daten in Datenkonzentratoren gesammelt werden und hier zum Transport via BACnet bereitstehen. Die Vorteile für DPIS manifestierten sich schon nach wenigen Monaten Testbetrieb an allen vier Pilotstandorten. So erschöpft sich das System nicht im bloßen zentralen Erfassen von Zählerständen, sondern erlaubt darüber hinaus die Einleitung zeitnaher, gezielter Maßnahmen (per E-Mail, SMS etc.). Dank des integrierten Reporting- und Analysetools wird die Analyse von historischem und aktuellem Datenmaterial – und hiermit das Aufzeigen von Trends und Ausblicken – ermöglicht. Mit Hilfe ergänzenden Datenmaterials zu Jahreszeiten, Wetterlagen und standortspezifischen Faktoren können Energieflüsse ermittelt werden. Zentrale Überwachung dank BACnet activeOperation ist eine integrierte Portallösung für das Management von Gebäuden und Anlagen. Sie wird bei I.T.E.N.O.S. in hochsicherer activeOperation in Kombination mit BACnet versetzen DPIS nun in die Lage, Potenziale sowohl beim Energiesparen als auch beim Energieeinkauf möglichst optimal auszuschöpfen. 20 BACnet Europe Journal 8 03/08 Deutsche Post Immobilienservice GmbH (DPIS) is a subsidiary of Deutsche Post and one of the biggest real estate owners in Germany. DPIS manages approximately 8,600 properties, not only office and administrative buildings but also freight and letter centres. The freight and letter centres consume lots of energy. When for instance the rolling gates stay open too long at low temperatures, the consequence is a substantial increase in energy demand to reach the preset room temperature again. Energy counter readings real-time In the past, DPIS had to record the counter readings manually and could only perform retrospective analyses on the basis of the utility bills – a lengthy and quite imprecise method. Against this background, DPIS wanted the test and introduction of a new system as soon as possible. This system was supposed to make available the counter readings of the energy counters real-time and to support further measures to save energy in an efficient Anwendungen Solutions Wie im Post-Tower Bonn lässt sich auch in den Fracht- und Briefzentren der Deutschen Post AG Energie sparen. Like in the Post-Tower Bonn, the freight and letter centers of the German Post AG can save energy. identification of trends and forecasts. Additional data on seasons, weather and location specific factors help define energy flows. activeOperation in combination with BACnet enables DPIS, not only to save energy, but also to optimise their energy purchase. © Deutsche Post World Net way. DPIS decided for the product activeOperation of I.T.E.N.O.S., Bonn, mainly because the offer met the requirement of a standardized communication interface – BACnet. As a prerequisite, DPIS had to outfit all locations with electronically readable counters and bus-compatible temperature sensors. Their data is collected in data concentrators and is made available for transport via BACnet. Central control thanks to BACnet activeOperation is an integrated portal solution for the management of buildings and facilities. At I.T.E.N.O.S. it is hosted in high security surroundings, but accessible via normal web browser. Thanks to BACnet, activeOperation enables the central monitoring and control of decentralized facilities, of different vendors and with most different applications. The benefits for DPIS became clear already after few month of test operation in four pilot locations. The system is not only suitable for the central recording of counter readings, but also for the initiation of prompt and efficient measures (via e-mail, SMS or the like). Thanks to the integrated reporting and analysis tool, the analysis of historical as well as current data is enabled – and thus the Wolfgang Heck Telematik Leiter Technische Realisierung & Produktmanagement I.T.E.N.O.S. GmbH Wolfgang.Heck@itenos.de www.itenos.de BACnet Europe Journal 8 03/08 21 Anwendungen Solutions Fit for Future – neue Gebäudeleittechnik an der Universität Stuttgart Future-proof Building Supervisory Management System at the University of Stuttgart Mit einer modernen BACnet Kommunikation zur Leitebene und einer komfortablen Bedienoberfläche mit dem MPlus System hat die Universität Stuttgart ein zukunftsfähiges System erhalten, das die Bewirtschaftung der Gebäude sicher und wirtschaftlicher macht. With state-of-the-art communication between the BACnet and the control system and a user-friendly operator interface using the MPlus system, the University of Stuttgart now has a system that is fit for the future. This makes the building operation safer and more efficient. Im Zuge der Ausschreibung zur Errichtung einer modernen und einheitlichen Gebäudeleittechnik mit Energiemanagement Stufe 2 wurde die Johnson Controls Systems & Service GmbH im September 2006 damit beauftragt, die auf dem fi rmenneutralen Datenübertragungssystem FND basierende Leitzentrale der Universität Stuttgart auf die neueste Technik mittels BACnet Kommunikation zu erweitern. Gleichzeitig beauftragte das Universitätsbauamt im Rahmen der Ausschreibung zusätzliche Dienstleister mit der Erweiterung und Erneuerung der MSR-Technik einzelner Universitätsgebäude sowie deren Anbindung an das zentrale Gebäudeautomationssystem. Universitätsbauamt Stuttgart gemeinsam mit den GAPlanern der Fc.ingenieure das bestehende Pfl ichtenheft für FND um den BACnet Anteil entsprechend der AMEV Empfehlung „BACnet 2007“. Damit schufen sie die Voraussetzungen für die einheitliche Aufschaltung der verschiedenen neue MSR-Komponenten auf die Gebäudeleittechnik. Zudem wurde im Rahmen von Konformitätstests mit allen beteiligten Firmen die Einhaltung des Pfl ichtenhefts anhand von Beispielen durchgearbeitet, um ein gemeinsames Verständnis für die Projektierung der einzelnen Teilbereiche zu erzielen. Im Rahmen der Umsetzung installierte Johnson Controls dann zunächst die Gebäudeleittechnik mit Metasys® Web Access (MWA) und zwei Bedienplätze inklusive des SQL Datenbankservers. Das integrierte Softwarepaket des MPlus Systems bestehend aus M-Graphics (Anlagengrafi ken mit Animation), M-Alarm (Alarm Softwarepaket mit Reports), M-Trend (Trenddarstellung und Auswertung) sowie dem MPlusExplorer (zum Navigieren im System) ermöglicht die zentrale und komfortable Steuerung des Systems. Eine moderne SQL Datenbank dient zur Speicherung der Trenddaten. Einheitliche Aufschaltung Um den hohen Anforderungen der Universität gerecht zu werden und alle bisher verwendeten Benutzeradressen bei FND und BACnet zu vereinheitlichen, setzte Johnson Controls auf ein MPlus Serversystem mit „Name Server“. Vor dem Beginn der eigentlichen Umsetzung aktualisierte und ergänzte das Eine innovative Gebäudeleittechnik für die innovative Universität. An innovative Building Management Supervisory System for the innovative University. 22 BACnet Europe Journal 8 03/08 Anwendungen Solutions right conditions for consistent switching of the various BMS components by the building automation system. To achieve a common understanding for the various projects involving subsections of the system, conformity tests were performed with all of the companies involved, by working through examples to ensure compliance with the system specifications. Von FND zu BACnet Im nächsten Schritt stellten die Techniker von Johnson Controls die sechs GAKnoten von der bestehenden FND-Kommunikation zur Leitzentrale auf die neue BACnet Kommunikation um. Hierbei wurden die FND Datenpunkte in BACnet Objekte umgewandelt sowie das Zeitschalten in BACnet Objekte Kalender und Schedule umgesetzt. Das Ereignisschalten und die zyklischen Programme der jeweiligen GA-Knoten wurden beibehalten. Danach schalteten die Johnson Controls Experten die BACnet GA-Knoten und BACnet Controller in den einzelnen Teilbereichen auf das neue GLT MPlus System auf und passten die 16-stellige FND Adressen über Regeln an die neue 26-stellige Adress-Syntax an. Abschießend wurden die bestehenden Anlagengrafi ken konvertiert und dynamisiert. In the call for tenders for the installation of a state-ofthe-art integrated building services and Stage 2 energy management system, Johnson Controls Systems & Service GmbH in September 2006 was awarded a contract to bring the University of Stuttgart’s control centre, which was based on the vendor neutral FND communication protocol, up to date with the latest BACnet communications technology. As part of the same call for tenders, the University Construction Board awarded contracts to other vendors for the extension and modernisation of the BMS technology in individual buildings, as well as for connecting these buildings to the central building services management system. Consistent switching To meet the University’s high exacting expectations and standardise all existing FND and BACnet user addresses, Johnson Controls designed an MPlus server system including a name server. Prior to the actual implementation, the Stuttgart University Construction office partnered with the building automation planners at Fc.ingenieure to update and expand the existing system specifications for FND, to include BACnet in accordance with the “BACnet 2007” recommendations published by AMEV. This created the Johnson Controls then began the implementation by installing the building services management system with Metasys® Web Access (MWA) and two operator control stations including an SQL database server. The MPlus System is comprised of an integrated software package consisting of M-Graphics (animated system graphics), M-Alarm (alarm software with reports), M-Trend (trend display and evaluation), and the MPlusExplorer (for system navigation), allowing for convenient, centralized control of the system. The trend data is saved in a state-of-the-art SQL database. From FND to BACnet In the next step, the Johnson Controls engineers switched the six building automation nodes over from the existing communication system between the FND and the control centre to the new BACnet communication system. This involved converting the FND data points into BACnet objects as well as implementing the time switching as BACnet Calendar and Schedule objects. The event switching and the cycling programs of the various building automation nodes remained unchanged. The specialists from Johnson Controls then switched the BACnet building automation nodes and the BACnet Controller in the various portions of the system over to the new MPlus BSM system and converted the 16-figure FND addresses to the new 26-figure address syntax according to a rule system. Finally, they converted the existing system graphics and made them dynamic. Projektbeteiligte Project Participants Universitätsbauamt Stuttgart und Hohenheim Universität Stuttgart Dezernat Technik und Bauten Fc.ingenieure GmbH, Ettlingen Datentechnik Fries, Dachau H&K, Theres JohnsonControls Systems & Service GmbH, Stuttgart Kieback&Peter, Stuttgart Messner Gebäudetechnik, Stuttgart Siemens Building Technologies, Stuttgart Ewald Stadelmeier Ewald.stadelmeier@jci.com Johnson Controls Systems & Service GmbH www.johnsoncontrols.com BACnet Europe Journal 8 03/08 23 Anwendungen Solutions Gebäudeautomation XXL auf der Neuen Messe Stuttgart Neue Messe Stuttgart is Building Automation XXL Mit dem Bau der Neuen Messe Stuttgart waren 1000 Firmen mit insgesamt 10.000 Arbeitern beschäftigt. Sie richteten die bislang größte Baustelle Deutschlands ein. Zur Ausführung der Gebäudeautomation mit ihrem System ProGrafNT/PMC wurde Neuberger beauftragt. About 1,000 companies and 10,000 construction workers were involved in building the Neue Messe Stuttgart – Germany’s largest construction site so far. Neuberger received the order to execute the building automation using their ProGrafNT/PMC system. Für die Neue Messe Stuttgart entstanden auf einem 83 ha großen Grundstück sieben Standard-Messehallen, eine Hochhalle und ein Kongresszentrum, so dass nun 100.000 m² Ausstellungsfläche genutzt werden können. Für Neuberger war eine Herausforderung bei diesem 10 Mio. Euro Auftrag die Bewältigung des engen Zeitplans, denn die gesamte Bauzeit bis zur Teileröffnung betrug nur 33 Monate. Eine wichtige Anforderung an die Gebäudeautomation bestand in der Umsetzung des im Messebau dieser Größenordnung neuartigen Schichtlüftungsprinzips, um besonders energiesparend und komfortabel ein angenehmes Raumklima zu schaffen. Der laufenden Projektausführung kam die gute Zusammenarbeit mit der Planungsgruppe M+M AG zugute. 40.000 Informationspunkte Zum Leistungsumfang gehörten 400 Schaltschrankfelder, 166 Automationsstationen und insgesamt 40.000 Informationspunkte, darunter 2000 Temperaturfühler. Diese sind nicht nur in den 120 Lüftungsanlagen, den Heizungs- und Kälteanlagen, sondern auch in den Büros und Hallen installiert. Über 1000 km Kabel verbinden Motoren, Sensoren und Aktoren mit den Schaltschränken. Um ein solch ausgedehntes Gebäudeautomationsnetz mit vielen Teilnehmern und Informationspunkten fristgerecht und rationell aufbauen und fehlerfrei übergeben zu können, setzte man auf das leistungsfähige BACnet/IPProtokoll. Jede Halle und die Verbindungsgebäude erhielten einen eigenen Gebäudeleitrechner zur Kommunikation mit den Automationsstationen und den Raumreglern. Mit dem zentralen Management-Leitrechner im Serverraum der Hochhalle behält der für den Betrieb Verantwortliche ständig den Überblick über die gesamte Liegenschaft. Das weit verzweigte Netz verbindet durchgängig Management-, Leit- und Feldebene. Dabei ist eine ManagementGLT den elf Leitrechnern und sechs Bedienstationen in den Hallen übergeordnet. Für eine hohe Verfügbarkeit gibt es für die Management-GLT einen Backup-Server. Beide sind mit Ethernet gekoppelt und bilden ein redundantes Parallelsystem mit gegenseitiger Überwachung und zyklischer Datensicherung. Es steht so immer ein Reserveserver mit allen aktuellen Daten bereit. Monteure bei der Schaltschrank-Inbetriebnahme. Technicians on commissioning of control cabinet. 24 BACnet Europe Journal 8 03/08 Die Leitrechner kommunizieren mit 166 im gesamten Messegelände verteilten PMC -Automationsstatio nen und einer Siemens PX in der Heizungsanlage über das BACnet/IP-Protokoll. Die mit LON vernetzte Beleuchtung und Beschattung (ca. 5000 Informationspunkte) ist via LON-OPC-Server angebunden, eine Siemens S7-Automationsstation für den Entlastungstunnel via OPC. Neu entwickelter Verbrauchskostenmanager Um den Betreiber bei den umfangreichen und ständig wechselnden Verbrauchskostenverteilungen zu entlasten, wurde auf der Managementebene ein von Neuberger neu entwickelter Verbrauchskostenmanager eingesetzt. Er erhält von den Leitrechnern laufend alle Energieverbräuche der Heizungs-, LüftungsKlima- und Sanitäranlagen, die mit Hilfe von fast 2000 M-Bus-Zählern erfasst werden. Da neben den Verbräuchen auch alle Messwerte und Schaltzustände der großen Anlage im Langzeitarchiv geführt werden, entsteht im Laufe der Zeit eine wertvolle strukturierte Datenbasis, die man jederzeit in vorgefertigten Archivcharts visualisieren und zur Überprüfung und weiteren energetischen Optimierung verwenden kann. Im seit Herbst 2007 laufenden regulären Messebetrieb hat sich das innovative Sicht über die Neue Messe Stuttgart. Panoramic View at south Germany´s biggest exhibition hall Stuttgart. Klimatisierungs- und Automationskonzept bereits zur Zufriedenheit des Betreibers, der Aussteller und Messebesucher in der Praxis bewährt. On an area of 83 hectares 7 standard exhibition halls, the Grand Hall (South Germany’s biggest exhibition hall) as well as a Congress Center have been built. Thus, an exhibition space of 100,000 m² is available. With an order volume of 10 Mill. Euro this was the biggest order Neuberger ever obtained and the challenge was to fulfill all requirements within a very tight operating schedule as the total construction period lasted only 33 months. An important requirement to the building automation was the realization of an innovative layer ventilation system in order to create an agreable air condition in an energy-saving and comfortable way. The good Project realization also came due to the good Teamwork with the Planungsgruppe M+M AG. 40,000 information points The scope of supply includes 400 control cabinet fields, 166 automation stations and a total of 40,000 information points, among them there are 2,000 temperature sensors. These sensors are not only installed in the 120 ventilation plants and the heating and cooling plants but also in the offices and halls. More © Projektgesellschaft Neue Messe GmbH than 1,000 km of cable were used to connect motors, sensors and actuators with the control cabinets. mutual monitoring and cyclic data backup. So a backup server with all actual data is always available. In order to be able to establish such a comprehensive building automation system with many stations and data points efficiently and in due time and to fulfill all requirements, the highperformance BACnet/IP Protocol was used. The host computers communicate with 166 PMC automation stations which are distributed on the entire trade fair ground and a Siemens PX in the heating plant via the BACnet/IP Protocol. The LON internetworked lighting and shadowing (approx. 5,000 information points) is connected via LOC-OPC-Server and a Siemens S7 automation station for the discharge tunnel via OPC. Every hall as well as the link buildings are equipped with their own host computer for communication with the automation stations and the room controllers. Via the central management host computer in the server room of the Grand Hall the responsible person is able to supervise the entire property all the time. The widely branched network is continuously connecting the management level, process control level and field level. Here a supervisory Management Server monitors the 11 host computers and the 6 operator’s panels in the halls. To ensure a reliable availability of the Management Server, a backup server is provided. Both are connected via Ethernet and form a redundant parallel system with the large plant are recorded in the long-time archive and so, in the course of the time, a valuable and structured database will be generated, which can be visualized in archive charts at any time and can be used for analysis and further energy optimisation. Regular trade fair operations at Neue Messe Stuttgart began in autumn 2007 and since then the innovative air-conditioning and automation concept is working to the complete satisfaction of user, exhibitors and visitors. New operating cost manager In order to facilitate the extensive and ever-changing operating cost distribution to the user, an operating cost manager, developed by Neuberger, was used on the management level. This operating cost manager continuously receives all energy consumption values of the heating, ventilation, air conditioning plants and sanitary facilities from the host computers. These values are measured by means of nearly 2,000 M-Bus counters. Additionally to the consumption values all measured values and switching states of Bernd Deutschmann Technical writer Neuberger Gebäudeautomation GmbH & Co. KG info@neuberger.net www.neuberger.net BACnet Europe Journal 8 03/08 25 Anwendungen Solutions Effektive Integration hinter historischer Fassade Effective Integration behind ancient Facade Das Haus 104/110 Boulevard Haussmann mit sieben Geschossen, zwei Tiefgaragengeschossen und 12.000 Quadratmetern Bürofläche wurde jetzt vollständig saniert und restauriert. Bei der technischen Ausstattung setze man auf BACnet und die Gebäudeleittechnik von Kieback&Peter. The building 104/110 Boulevard Haussmann with its seven stories, a two-level underground parking lot and 12,000 m² office space has just recently been completely re-developed and renovated. For the technical facilities modern BACnet technology and Kieback&Peter were called for. Der Boulevard Haussmann in Paris gehört zu den großen Boulevards, die im 19. Jahrhundert unter der Herrschaft Napoleon III. von Baron Haussmann angelegt wurden. Bis heute prägen sie das Bild von Paris. Hier liegen die berühmten Kaufhäuser Galeries Lafayette und Le Printemps. Außerdem haben viele Banken und Versicherungen hier ihren Sitz. Die kompletten Umbauarbeiten hat die Firma Bouygues übernommen. Natives BACnet Die historische Fassade des Gebäudes wurde original im Architekturstil renoviert, den Baron Haussmann prägte. Bei der technischen Ausstattung setze man auf moderne Technologie. Dazu gehört moderne Gebäudeautomation: Kieback&Peter hat das Gebäude mit einer modernen Gebäudeleittechnik auf Basis des BACnet Protokolls ausgestattet. Das Automationssystem DDC4000 von Kieback&Peter steuert und regelt die Heizungsund Klimaanlagen sowie die Stromversorgung. Es verfügt über natives BACnet und kommuniziert über Ethernet (TCP/IP, BACnet). Die zwölf Luftreinigungsund Klimaanlagen und weitere Anlagen zur Wärmeund Kälteversorgung sind in das Automationssystem integriert. Das Automationssystem DDC4000 sorgt für sicheren und effi zienten Anlagenbetrieb. Die Automationsstation DDC4200 verfügt über einen Touchscreen mit großer Bedienoberfläche. Mit gut verständlichen Klartexten und Anlagenbildern ist die Bedienung einfach und komfortabel. Darüber hinaus können technische Störungen schnell identifi ziert werden und auch Auswertungen über Trendkurven vorgenommen werden. Auch Stromversorgung, Beleuchtung und Notstromaggregat sind integriert. Automationsstationen DDC4200 steuern und regeln die Niedrigspannungsversorgung. Das Stromaggregat ist über eine Schnittstelle Jbus/ BACnet angeschlossen. Es verfügt über seine eigene 26 BACnet Europe Journal 8 03/08 speicherprogrammierbare Steuerung, die für die Sicherheit zuständig ist. Die Stromzähler sind ebenfalls über Jbus/BACnet Schnittstellen mit dem System vernetzt. Energieeffizienz Für die Raumautomation wird das auf LON basierende Raumautomationssystem technolon mit Raumregler der Produktlinie RCN eingesetzt. Die RCN Regler sind eu.bac zertifi ziert. Die eu.bac Zertifi zierung garantiert hohe Regelgenauigkeit und Energieeffi zienz. Um die Raumautomation nahtlos mit dem IP-Netz zu verbinden, wurde eine LON/IP Architektur gewählt. Sie nutzt damit dasselbe Kommunikationsmedium wie BACnet/IP. Diese Architektur zeigt, dass LON und BACnet jeweils ihre eigene Rolle spielen und harmonisch über dasselbe Netz arbeiten können. Die Mitarbeiter können mit Funkfernbedienungen die Regler bedienen und die Raumkonditionen nach ihren Bedürfnissen einstellen. Die technolon Raumautomation steuert Temperatur und Sonnen- schutz in den Büroräumen genau nach Bedarf. Damit spart sie viel Energie. Auf der Managementebene wurde die Kieback&Peter Gebäudeleittechnik Neutrino-GLT installiert. In der Neutrino-GLT sind sowohl LON als auch BACnet integriert. Nicht weniger als 6.000 Datenpunkte werden über die GLT verwalten, davon 500 BACnet Objekte. In der GLT-Leitzentrale sind gleichzeitig ein Client und Server aktiv. Dem Server steht eine leistungsfähige GLT-Datenbank sowie der direkte kommunikative Zugriff auf alle Informationen der betriebstechnischen Anlage BTA zur Verfügung. Der Client hingegen ist für die Darstellung und Abarbeitung der GLT-Bedienoberfläche verantwortlich. The Boulevard Haussmann in Paris is one of the great boulevards constructed in the 19th century under Napoleon III by Baron Haussmann. Even today these Anwendungen Solutions Moderne Gebäudeautomation hinter historischer Fassade am Boulevard Haussmann in Paris. Modern building automation behind an historical facade of Boulevard Haussmann in Paris. DDC4200 automation station has a touch screen with a large user interface. With plain text and installation graphics that are easy to understand operation is quite straightforward. Any technical faults can be identified promptly and evaluations carried out via trend curves. The power supply, lighting and emergency power supply are also integrated. The DDC4200 automation stations control and regulate low-voltage power supply. The power supply is connected via a Jbus/BACnet interface and has its own API responsible for security. The electricity meters are also networked with the system via Jbus/BACnet interfaces. boulevards still very much shape the city. Here you can find the famous department stores Galleries Lafayette and Le Printemps. Many banks and insurance companies have their headquarters in this area. All structural alteration works were carried out by the construction company Bouygues. Nativ BACnet The historical facade of the building was restored in original Haussmann style, however for the technical facilities modern technology was called for. This includes modern building automation: Kieback&Peter installed a central building control system based on the BACnet protocol. The Kieback&Peter DDC4000 automation system controls and regulates the heating and air-conditioning systems together with the power supply. The DDC4000 automation system is native BACnet and communicates via Ethernet (TCP/ IP, BACnet). The 12 air-conditioning systems and other installations such as district heating and cooling are integrated in the automation system The DDC4000 automation system provides for secure and efficient system operation. The Energy efficiency The chosen room automation solution is the LON-based technolon system with room controllers from the RCN product range. The RCN controllers are eu.bac certified. The eu.bac certification guarantees high control accuracy and energy efficiency. LON/IP architecture ensures that the room automation is easily connected to the IP-network, using the same communication medium as BACnet/IP. This architecture shows that LON and BACnet both have their respective parts to play, but can work harmoniously via the same network. With a remote control the room occupants can set the controllers and thus adjust the room conditions to suit their requirements via radio frequency. technolon room automation regulates the temperature and antiglare protection as necessary, this way saving a lot of energy. The Neutrino-GLT central building control system was installed at management level. Both LON and BACnet are integrated in the Neutrino-GLT. No less than 6,000 data points are governed via the GLT, 500 of which are BACnet objects. In the GLT primary control unit both Client and Server are active at the same time. The Server can access a highperformance GLT database and also has direct, communicative access to all information of the operational systems BTA. The Client on the other hand is responsible for the presentation and execution of the GLT user interface. Lucien River General Manager Kieback&Peter France river@kieback-peter.fr www.keback-peter.de BACnet Europe Journal 8 03/08 27 Anwendungen Solutions Höchstmaß an Energieeffizienz Highest Level of Energy Efficiency Das Klinikum Bremerhaven/Reinkenheide ist ein Musterbeispiel für Energieeffizienz im Krankenhaus. Dank der umfassenden Erneuerung aller gebäudetechnischen Anlagen konnte der Energieverbrauch um über 25 Prozent reduziert werden. The Clinical Center of Bremerhaven/Reinkenheide is a model for energy efficiency in hospitals. The comprehensive upgrading of all building services installations enabled energy consumption to be reduced by more than 25%. Im Rahmen eines Energiespar-Contracting Projektes in Zusammenarbeit mit Siemens spart das Klinikum jährlich 519.000 Euro an Energiekosten und entlastet die Umwelt um 3.200 Tonnen CO2 pro Jahr. Um die Nachhaltigkeit und damit auch die Wirtschaftlichkeit zu sichern, wurde der Vertrag für eine Laufzeit von 12 Jahren geschlossen. Im Jahr 1976 eröffnet war das Klinikum Bremerhaven im Stadtteil Reinkenheide mit seinen 680 Betten das mo- dernste seiner Art im Land Bremen. Bis heute konnte es seine Spitzenstellung als Therapie- und Diagnosezentrum kontinuierlich ausbauen. Im Gegensatz dazu haben die gebäudetechnischen Anlagen über die Betriebsjahre ihre Leistungsfähigkeit und Effi zienz insbesondere im Hinblick auf den Energieverbrauch eingebüsst. Im Jahr 2004 mussten rund zwei Millionen Euro für Primärenergie aufgewendet werden. Es bestand dringender Handlungsbedarf für eine umfassende Sanierung und Modernisierung. Mit einer von der Klimaschutzagentur „Bremer Energie-Konsens“ erstellten Ausschreibung im Frühjahr 2006 wurde das Vergabeverfahren für das Energiespar-Contracting Projekt europaweit gestartet. Die Agentur steuerte den Vergabeprozess und stand auch während der Realisierungsphase dem Bauherrn beratend zur Seite. Die Siemens Division Building Technologies überzeugte mit einem Angebot, das eine Reduktion des Jahresenergieverbrauchs um 25 Prozent garantierte und gewann den Auftrag. Die baulichen Maßnahmen sowie die Modernisierungs- und Optimierungsmaßnahmen der technischen Anlagen begannen im April 2006 und dauerten rund 12 Monate, da nahezu alle notwendigen Baumaßnahmen im laufenden Betrieb durchgeführt werden mussten. 120 Einzelmaßnahmen Die umgesetzten rund 120 Maßnahmen betrafen alle gebäudebetriebstechnischen Einrichtungen, wie die Heizungsinfrastruktur, Kälteerzeugung, Erneuerung der G roß k üche n spü l m a s ch i nen, medizinische Druckluftversorgung, Niederspannungshauptversorgung und Dampfsterilisatoren. Die über 70 raumlufttechnischen Anlagen wurden komplett entkernt und mit der BACnet Automation DESIGO PX auf Contracting Partner Klinikum Bremerhaven. 28 BACnet Europe Journal 8 03/08 den neuesten Stand der Technik gebracht. Automatisierung und Energiemanagement kommunizieren mit BACnet/IP und stellen ein Höchstmaß an Energieeffi zienz sicher. Die Energieeinsparungen sind beachtlich, wie Jürgen Breuer, Technischer Leiter des Klinikums an einigen Beispielen aufzeigt. So konnte der Energiebedarf für Ferndampf zur Klimatisierung, zum Kochen und zur Sterilisation um rund 6 200 MWh oder um 72 Prozent verringert werden, was dem thermischen Energieverbrauch von rund 350 Einfamilienhäusern entspricht. Die Klimaanlagen, die nicht zum Operationsbereicht oder zur Intensivpflege gehören, beginnen jetzt erst bei einer Außentemperatur von 2°C zu heizen. Bevor jedoch die Temperatur unter diesen Grenzwert sinkt, kann über ein hocheffi zientes Wärmerückgewinnungssystem der Abluft soviel Energie entzogen werden, daß kein zusätzlicher Heizbetrieb notwendig ist, so Breuer. Ein weiteres großes Einsparpotenzial betrifft die bedarfsgerechte Wärmeversorgung des Gebäudes. Durch den Einsatz von hocheffi zienten Umwälzpumpen werden rund 50 MWh Strom pro Jahr eingespart. Durch die Erneuerung der Heizkreisregelung werden die Raumtemperaturen innerhalb der Nachtstun- Anwendungen Solutions den, beziehungsweise außerhalb der Nutzungszeiten in bestimmten Gebäudebereichen abgesenkt. Die Energieeinsparung für die Raumheizung liegt bei rund 5 000 MWh oder 50 Prozent, das ist in etwa soviel wie 280 Einfamilienhäuser verbrauchen. Das Wichtigste für die Patienten im Krankenhaus sind und bleiben kompetente Ärzte und moderne Medizintechnik. Doch das medizinische System und die rasche Genesung der Patienten funktioniert nur mit guter haustechnischer Infrastruktur. Hier hat das Klinikum Bremerhaven/Reinkenheide einen Meilenstein hinsichtlich Anlagenqualität, nachaltiger Kosteneinsparung und Energieoptimierung gesetzt. In the context of an Energy Management Contracting project in association with Siemens the Clinical Center is achieving savings of 519,000 euros in energy costs and reducing CO2 emissions by 3,200 tonnes annually. This contract was concluded for a period of twelve years in order to ensure sustainability and thus economic efficiency. The 680-bed Clinical Center opened in Bremerhaven/ Reinkenheide in 1976 was the most modern of its kind in the state of Bremen. It has continued to extend its leading position as a therapy and diagnostic center right up to the present day. By contrast, the productivity and efficiency of its building services installations have declined over the years, especially as regards energy consumption. Primary energy costs amounted to some two million euros in 2004. There was an urgent need for extensive refurbishment and upgrading. The bidding process for the Energy Management Contracting project was launched throughout Europe in the spring of 2006 with an invitation to tender drawn up by the “Bremen Energy Consensus” climate protection agency. The agency controlled the bidding process and also advised the owner of the premises during the implementation phase. Siemens’ Building Technologies Division submitted a convincing bid guaranteeing a 25% reduction in annual energy consumption, and won the contract. The structural works and the upgrading and optimization of the technical installations started in April 2006 and lasted about twelve months, since almost all the necessary structural work had to be performed while the premises continued to function normally. 120 separate steps Some 120 steps were taken, affecting all the building services installations, such as heating infrastructure, cooling equipment, replacing the canteen dishwashers, medical compressed-air supply, main low-voltage supply and steam sterilizers. More than 70 conditioned-air systems were completely disassembled and rebuilt to the latest state of the art with the BACnet based building automation systems DESIGO PX. Building automation and energy management operate based on BACnet/IP and assure the highest level of energy efficiency. Remarkable energy savings have been achieved, as Jürgen Breuer, Technical Manager of the Clinical Center, explains using several examples. For instance, the power required in terms of steam supplies for air conditioning, cooking and sterilization has been reduced by some 6 200 MWh or 72%, equivalent to the thermal energy consumption of about 350 singlefamily houses. The air conditioning systems outside of the operating or intensive care sectors now only start heating at outdoor temperatures of 2°C. However, before the temperature falls below this threshold, so much energy can be extracted from the exhaust air via a highly efficient heat recovery system that additional heating generation is unnecessary, Jürgen Breuer adds. Loaddemand heat supply to the building represents a further major source of potential savings. The use of highly efficient circulating pumps enables some 50 MWh of electricity to be saved annually. The upgrading of the heating circuit control system enables room temperatures in certain parts of the building to be reduced during the night, i.e. outside their hours of use. The energy savings on room heating amount to some 5 000 MWh or 50%, which corresponds approximately to the consumption of 280 single-family houses. The most important considerations for patients in the hospital are, as ever, competent Infrastruktur für Ärzte und Patienten. Infrastructure for doctors and patients. doctors and up-to-date medical technology. However, the medical system and the rapid recovery of patients depend on good building services infrastructure. This is where the Bremerhaven/ Reinkenheide Clinical Center has achieved a milestone in terms of installation quality, sustained cost economies and energy optimization. Michael Hartmann-Skörup Head of SBT DE BAU Energy & Environmental Solution Siemens Building Technologies GmbH & Co. oHG michael.hartmannskoerup@siemens.com www.siemens.com/ buildingtechnologies BACnet Europe Journal 8 03/08 29 Anwendungen Solutions Landschaftsverband Rheinland – Integration in bestehende GLT Rhineland Regional Council: BACnet Integration in Existing System Der Landschaftsverband Rheinland setzt bei seiner GLT auf ein offenes System und vollständige Integration. Die in seinen neugebauten Förderschulen in Linnich und Oberhausen eingesetzten DDC-Controller miles® -AS29 der Messner Gebäudetechnik werden via BACnet in die bestehende GLT eingebunden. The Rhineland Regional Council is focusing its building control tech-nology on an open system and full integration. The DDC controller miles®-AS29 from the Messner Gebäudetechnik GmbH company, which is being used in its newly built special education schools in Linnich and Oberhausen, will be integrated into the existing building control technology via BACnet. Der Landschaftsverband Rheinland (LVR) ist ein Zusammenschluss von 14 kreisfreien Städten und 13 Kreisen. Mit seinen 40 Förderschulen, zwei Krankenschulen, zehn Krankenhäusern, sechs Museen und seinem Heilpädagogischem Netzwerk sowie als größter Leistungsträger für Menschen mit Behinderungen in Deutschland erfüllt der LVR Aufgaben in der Behinderten- und Jugendhilfe, in der Psychiatrie und der Kultur, die rheinlandweit wahrgenommen werden. Seit Jahren ansteigende Schülerzahlen an den Rheinischen Förderschulen des LVR machten Neubauten in Linnich und Oberhausen erforderlich. Schwerpunkt dieser Förderschulen ist die Betreuung von körperbehinderten Kindern. Neben den Klassen-, Fachund Therapieräumen sowie die Verwaltungsräumen und die Schülerbibliothek wurden auch Turnhallen und Lehrschwimmbecken mit den zugehörigen Sanitärräumen errichtet. Offene GLT in Köln Bisher sind ca. zehn Liegenschaften des LVR in das Gebäudemanagementsystem der Hauptverwaltung in Köln integriert. Dabei sind sechs verschiedene Regelfabrikate über BACnet, LON oder OPC aufgeschaltet. Ziel ist es, alle Liegenschaften in das Managementsystem aufzunehmen. Die Zentrale arbeitet nach dem Prinzip der verteilten Server und kann somit praktisch unbegrenzte Datenmengen verarbeiten. Neben der Monitoring-Funktion übernimmt sie die Alarmüberwachung, die Trendaufzeichnung und dient als Webserver. Von allen angeschlossenen Liegen- 30 BACnet Europe Journal 8 03/08 schaften können deren Webseiten abgerufen werden und je nach Zugangsberechtigung des Users ist die Systembedienung möglich. Messner-miles® integriert sich via BACnet In den Förderschulen in Oberhausen und Linnich sind BACnet-Controller miles® AS29 der Messner Gebäudetechnik eingesetzt. Sie arbeiten für jede Schule als autarkes System. Im Wesentlichen übernehmen sie die Heizungs-, Lüftungsund Klimaregelung. Hinzu kommt der Datenaustausch mit der Badewassertechnik der Schwimmbäder, der über MODBus realisiert ist. Hierbei werden Messgrößen wie der Chlorgehalt, der Redox- Wert, PH-Wert usw. an die miles® -AS29 und von dort an die GLT übertragen. In der FS Oberhausen sind zusätzlich die LON-Regler der Fußboden-Heizungsverteilung über die miles® -LONKopplung eingebunden. Die miles® -Stationen verwalten 130 Regelkreise und geben die Stellgrößen für die Ventile vor. Wichtige Meldungen und Messwertänderungen werden über DSL-Router als BACnetObjekte an die GLT nach Köln übertragen. Da für den Datentransfer das COVPrinzip gilt, garantieren die schnellen DSL-Standleitungen kurze Übertragungszeiten wie in einem lokalen Förderschule des LVR in Oberhausen. The Rhineland Regional Council special education school in Oberhausen. Anwendungen Solutions Netzwerk. An der Leitzentrale wandelt ein BACnet-OPCServer die Informationen in das benötigte OPC-Format um. Umgekehrt ist die vollständige Bedienung der miles® Controller über die Zentrale möglich. Zunutze macht man sich diese Möglichkeit insbesondere, um von den Anlagenbildern aus Sollwerte zu ändern bzw. Ferienpläne über das Schedule-Objekt einzutragen. The Rhineland Regional Council is an affiliation of 14 urban authorities and 13 districts. With its 40 special education schools, two schools for the sick, ten hospitals, six museums and its orthopedagogy network as well being Germany’s largest service provider for disabled people, the Rhineland Regional Council provides disabled, youth, psychiatry and cultural services throughout the Rhineland. The steadily rising number of pupils attending the Rhineland Regional Council’s special education schools over recent years had necessitated the construction of new buildings in Linnich and Oberhausen. These special education schools focus on the care of physically disabled children. Gymnasiums and swimming pools for swimming lessons as well as the related sanitary facilities were also built in addition to classrooms, specialty rooms and therapy rooms, administrative space and the school library. Open building control technology in Cologne Up to now approximately ten of the Rhineland Regional Council’s properties have been integrated into the building management system of the head administrative office in Cologne. Six different makes of controllers are connected there via BACnet, LON or OPC. The goal is to include all properties in the management system. The control center works on the principle of distributed servers which allows it to process almost BACnetOPCServer unlimited amounts of data. In addition to the monitoring function, it also handles alarm monitoring, trend recording and is used as web server. Websites can be called up from all connected properties and system operator control is possible if the user has the appropriate access rights. Messner-miles® integrated via BACnet The special education schools in Oberhausen and Linnich are equipped with BACnetcontroller miles®AS29 from the Messner Gebäudetechnik GmbH company. These function as independent systems for each school. Essentially, they handle the control of heating, ventilation and airconditioning. Also included is the data exchange with the swimming pool water technology which is implemented via MODBus. Variables such as chlorine content, redox value, PH value, etc. are transmitted to the miles®AS29 and from there to the building control technology system. The special education school in Oberhausen also has the LON controllers for floor heating distribution linked via the miles®-LON coupling. The miles® stations manage 130 control loops and specify the control variables for the valves. Crucial messages and changes in measured values are transmitted via DSL routers as BACnet objects to the Cologne building control technology system. Since data transfer uses the COV principle, the high-speed DSL dedicated lines guarantee short transmission times similar to a local network. At the control center a BACnetOPC server converts the information into the required OPC format. Vice versa, the miles® controller can be fully managed at the control center. This is particularly useful when reference values have to be changed using system screens or vacation plans have to be entered in the schedule object. GLT Köln / BMS in Cologne BACnet/IP DSL-Router Server Webserver Rufdienste / Workstation Paging services SQL-Server FS Oberhausen BACnet/IP DSL-Router miles®-AS29 LON-Regler für Fußbodenheizungsverteilung LON controllers for floor heating distibution BACnet/IP FS Linnich DSL-Router MODBus-Kopplung zur Badewassertechnik MODBus coupling to swimming pool water technology miles®-AS29 MODBus-Kopplung zur Badewassertechnik MODBus coupling to swimming pool water technology Volker Barufke Marketing Messner Gebäudetechnik volker.barufke@messner.de www.messner.de BACnet Europe Journal 8 03/08 31 A TOUCH of EXCELlence in B Wenn Gebäudemanagement wirklich leicht sein soll. Excel Touch 1:1 168 x 126 mm Excel Touch Pure operating efficiency, with application specific, rapid-access lists for data points, time programs, and parameters - bus-wide. Ideal for new construction and existing buildings. Visualizes applications of Excel Web and Excel 800/500/100/50. Excel Web Freely programmable HVAC controller with: BACnet/IP, LONWORKS®, Linux, Email/SMS alarming, web access, and many more. uilding Management. Excel Touch Pure Bedieneffizienz, mit anlagenspezifischen Schnellzugriffslisten für Datenpunkte, Zeitprogramme und Parameter, busweit. Ideal für Neuanlagen und Nachrüstung. Excel Web Frei programmierbare DDC mit den modernsten Zutaten: BACnet/IP, LONWORKS®, Linux, Email/SMS Alarmierung, Webzugang und vielem mehr. Visualisiert Applikationen von Excel Web und Excel 800/500/100/50. More information: phone +44 (0) 870 600 1659 +49 (0) 69 8064 281 hbs.info@honeywell.com Anwendungen Solutions DSM senkt Energiekosten mit BACnet Antrieben DSM cuts Energy Costs with BACnet Drives DSM, ein niederländisches Unternehmen für Life Science und Materialforschung, spart seit der Installation von drehzahlgeregelten Antrieben in den beiden Laborgebäuden auf dem Research Campus des Werks Chemelot in Geleen (NL) jährlich etwa 25.000 Euro an Energiekosten. Some 25,000 Euros of energy are being saved each year by DSM, a Dutch life sciences and material sciences firm, following the installation of variable speed drives within two laboratory buildings, located on the Research Campus at the Chemelot site in Geleen, the Netherlands. Das Projekt wurde von dem niederländischen Systemintegrator Regel Partners durchgeführt. Auf Anraten des Elektro- und Mechaniklieferanten Burgers Ergon entschied sich DSM bei der HLK-Anlage für Standard Drive-Frequenzumrichter von ABB, um auch das BACnet Kommunikationsprotokoll nutzen zu können. BACnet stellt die serielle Verbindung zur neuen Gebäudeleittechnik (GLT) her. Hierdurch wird ein Fernzugriff auf den Frequenzumrichter über das Internet ermöglicht, sodass Sollwertänderungen komfortabel über einen PC vorgenommen werden können. Durch das System entfällt nicht nur die Überprüfung der Sollwerte vor Ort, es erlaubt dem Benutzer auch sofort auf Änderungen zu reagieren. Da das BACnet-Protokoll speziell für die Gebäudetechnik entwickelt wurde, bietet es auch Standard-Tools für die Geräteintegration. BACnet bedeutet nicht nur eine einfache Installation, sondern liefert auch mehr Daten und gibt DSM die Möglichkeit einer besseren Kontrolle, Überwachung und Einstellung der Antriebe von einem einzigen Bedienplatz aus. Es werden umfangreichere Informationen über die Leistung der einzelnen Antriebe geliefert, und die Funktion der Gesamtanlage kann überwacht werden. für HLK-Anwendungen sind auch von BTL (BACnet Testing Laboratories) zugelassen. Bei dem ursprünglichen Belüftungssystem in Geleen wurden Leitschaufeln am Einlass verwendet, die den Luftstrom mechanisch um 80 bis 85% begrenzt haben, während die Elektromotoren im Dauerbetrieb mit voller Drehzahl liefen. Bei 24 Motoren mit einer Gesamtleistung von mehr als 400 kW ergab dies eine erhebliche Energieverschwendung. Der Austausch der Leitschaufeln am Einlass durch eine Drehzahlregelung der Lüftermotoren am Ein- und Auslass führte zu einer Energieeinsparung von mindestens 10%. Alle Motoren wurden ausgetauscht und durch neue Motoren mit jeweils eigenem ABB Standard Drive (IP54) für HLK-Anwendungen ersetzt. Die Montage erfolgte entweder an der Wand oder auf Montageplatten in der Nähe der Motoren. Alle 24 Frequenzumrichter können eine eigene, eindeutige Bezeichnung erhalten und so leichter in das GLT-System integriert werden. Jeder Frequenzumrichter besitzt entsprechend der Schaltung oder der jeweiligen Aufgabe eine Klartextbezeichnung. Der Wartungstechniker kann dadurch den Frequenzumrichter, seine Funktion und seinen Standort sofort identifi zieren. So kann das Wartungsunternehmen die gesamte Anlage, einschließlich der Antriebe fernüberwachen und spart dadurch Zeit und Geld bei der Reaktion auf Anlagenstörungen. Seit 2004 bietet ABB Antriebe für HLK-Awendungen mit voll integrierter oder „nativer“ BACnet Kompatibilität an. Deshalb benötigt der ABB Standard Drive für HLK-Anwendungen keine Anpassung mittels zusätzlicher Buskoppler. Frequenzumrichter von ABB ABB Frequenzumrichter IP54 im Werk Chemelot von DSM. Wall-mounted ABB drives IP54 at the Chemelot site of DSM. 34 BACnet Europe Journal 8 03/08 Anwendungen Solutions Electro Drive, der Partner von ABB für HLK-Antriebe in den Niederlanden, lieferte die Frequenzumrichter. Die Inbetriebnahme erfolgte mit Hilfe der in die Geräte integrierten InbetriebnahmeAssistenten und dem Assistenten für serielle Kommunikation. Bei der Inbetriebnahme erspart BACnet den Leittechnikspezialisten den Aufwand, Gateways für die Kommunikation mit den Geräten zu installieren. Durch BACnet können die Frequenzumrichter schon beim Anschluss die erforderlichen Einstellungen laden. Mit Hilfe der BACnet Schnittstelle können die Inbetriebnahme und Abstimmung von einem zentralen Ort aus erfolgen, wodurch sich die erforderliche Inbetriebnahmedauer deutlich verkürzt. Außerdem können Parametersätze mittels Steuertafel bequem zwischen den Frequenzumrichtern kopiert werden. Der Benutzer braucht nur die BACnet Gerätenummer zu ändern. Heute werden die Betriebsstunden, alle Motormesswerte, die Verbrauchszähler und der Status der physischen E/A der Frequenzumrichter überwacht und die Daten erfasst, indem die Frequenzumrichter einzeln im GLT-System abgefragt werden. Nur die Motordrehzahl wird im GLT-System grafisch angezeigt. Die Steuerung der Frequenzumrichter erfolgt durch fest verdrahtete E/A. Künftig plant Burgers Ergon jedoch, die Antriebe über die serielle Kommunikationsverbindung anzusteuern. Hierdurch werden die Verkabelungskosten weiter gesenkt und Verkabelungsfehler in der Anlage vermieden. Under the guidance of Dutch system integrator, Regel Partners and upon the advice of the electrical and mechanical contractor, Burgers Ergon, DSM opted for ABB standard drives for HVAC in order to harness the inbuilt BACnet communication protocol. BACnet provides the serial link to the new BMS, thereby giving remote access to the drive over the Internet, making any change to setpoints possible from the comfort of a PC. Apart from avoiding the need to physically check setting values, this facility enables the user to react instantly to any change. As the BACnet protocol is specially developed for building services, it offers standard tools for integration of devices. BACnet provides DSM with ease of installation as well as offering more data, better control and ease of monitoring and adjusting the drives from a single point. It gives more information about how each drive is performing and helps to monitor the performance of the overall building installation. This enables the responsible maintenance company to monitor the entire system including drives, remotely, thereby saving time and money in responding to any system fault. ABB has been offering drives for HVAC applications with a fully incorporated, or “native”, BACnet capability since 2004. Thus the ABB standard drive for HVAC did not need to be adapted using addon software gateways. ABB standard drives for HVAC are also approved to BTL (BACnet Testing Laboratories). The original HVAC air handling system at Geleen used inlet guide vanes, which mechanically restricted air flow to between 80 to 85% while the electric motors would run continuously, at full speed. With 24 motors, totalling over 400kW, this amounted to high energy wastage. Replacing the inlet guide vanes with variable speed control of the supply and return fan motors, reduced the energy consumption by at least 10%. Each motor was replaced and the new motors fitted with their own IP54 rated ABB standard drive for HVAC, either wall-mounted or on a mounting rack close to the motors. All 24 drives can be named uniquely to ensure better integration to the BMS system. Each drive is identified in clear text, in accordance with electrical schematics or depending on the drive’s task. This enables the maintenance engineer to immediately identify the drive, its function and its location need once they are connected. The BACnet interface enables drive commissioning and/or tuning from a central location, thereby considerably shortening the required commissioning time. Furthermore, when one parameter set is identified, it can be easily copied to other drives using the drive’s control panel. Only the BACnet device number needs to be changed by the user. Today, the running hours, all motor measurements, energy counters and status of physical I/O from the drives are monitored and the data collected by checking each drive individually in the BMS. Only the motor speed is displayed graphically within the BMS. The drives controls are based on hardwired I/O, but in future installations, Burgers Ergon, plans to also control the drives over the serial communication link. This will further reduce cabling costs and avoid any misconnection during installation. The drives were delivered and commissioned by Electro Drive, the HVAC drives partner for ABB in the Netherlands. The commissioning of the drives was carried out using the onboard wizards known as the start-up assistant and serial communication assistant. During commissioning, BACnet saves the control specialists from having to spend time inputting gateways to talk to the equipment. BACnet enables the drives to download the settings they Marcel Zevenbergen Sales Engineer Motors and Drives ABB B.V. Netherlands marcel.zevenbergen@ nl.abb.com www.abb.com/ motors&drives BACnet Europe Journal 8 03/08 35 Anwendungen Solutions Energiesparende Klimatechnik in der Berliner Charité Energy-saving Air Conditioning Technology at the Charité Hospital Berlin Der Paul-Ehrlich-Hörsaal der Charité – Universitätsmedizin Berlin – wurde mit einem energiesparenden Klimagerät von Hansa ausgestattet. Es enthält modernste Steuerungstechnik von Saia-Burgess Controls mit spezieller Speichertechnologie und BACnet-Anbindung. The Paul Ehrlich auditorium at the Charité hospital – university hospital in Berlin – has been equipped with an energy-saving air conditioning system which comprises the latest control technology from Saia-Burgess Controls along with dedicated memory technology and BACnet connection. Gegründet 1710, zählt die Charité zu den ältesten und traditionsreichsten Krankenanstalten in Deutschland. Sie ist heute zugleich eine der größten Universitätskliniken Europas. Getreu ihrer Mission „Forschen, Lehren, Heilen, Helfen“ widmen sich rund 14.000 Mitarbeiter der Krankenversorgung, der Wissenschaft und der Ausbildung des ärztlichen Nachwuchses. In den Hörsaal des Instituts für Mikrobiologie wurde im Jahr 2006 eine neue Klimaanlage eingebaut. Deren Controller von Saia-Burgess Controls wurde via BACnet problemlos mit der bestehenden zentralen Gebäude-Leitwarte der Charité verbunden, die aus dem Hause TAC stammt. Entwickelt und umgesetzt wurde das Steuerungskonzept von Hansa, einem führenden Unternehmen der Klima-Branche mit mehr als 30 Jahren Erfahrung im Bereich Klimaanlagen und Lüftung. Energiesparende Klimageräte Klimaanlagen werden gerne mit Energieverschwendung gleichgesetzt. Das Gegenteil beweist die Firma Hansa, die Durch die Steuerung dokumentiert: 85% Energieeinsparung. Documented by the control: 85% energy savings. 36 BACnet Europe Journal 8 03/08 sich auf eine besonders effiziente Klimatechnik für Gebäude spezialisiert hat. Gerade in Zeiten des wirtschaftlichen Drucks hat dies auch die Charité überzeugt, ihren Paul-Ehrlich-Hörsaal mit Hansa-Klimatechnik auszustatten. Die Raumluft wird in dem kompakten Klimagerät (Serie HKG-KOV-ER-071-S) gefi ltert, be-/entfeuchtet und bei Bedarf gekühlt bzw. geheizt. Bei bestehenden Raumverhältnissen zeigen sich die Kompaktgeräte gegenüber den üblichen Normalausführungen im Vorteil. Innovative Steuerungstechnik Aus Sicherheitsgründen erlaubte die Charité den einfach zu realisierenden Fernzugriff auf die mit WebTechnologie ausgestattete Steuerung nicht. Stattdessen erbrachte die Steuerung selbst den Beleg der Energieeinsparung mit Hilfe des integrierten Saia File Systems. Hierbei werden in csv-Dateien die jeweiligen Energieverbräuche und Temperaturen in Kombination mit den Leistungsdaten der Ventilatoren und Pumpen aufgezeichnet. Bei jeder Wartung wird das File System ausgelesen und bei Hansa dokumentiert. Die Daten liefern eindeutige Informationen und belegen die im hohen Qualitätsanspruch begründeten Versprechungen Hansas. Im Vergleich zu Umluftkühlsystemen (auch Splitsysteme) benötigt die Klimaanlage von Hansa im realen Langzeiteinsatz überzeugende 85 Prozent weniger elektrische Energie. Datenaustausch via BACnet Eine wesentliche Vorgabe war die Einbindung der Klimaanlage in die bereits auf dem Gelände der Charité installierte Gebäude-Leittechnik. Die einzelnen Gebäude werden über eine Leitstation von TAC bedient und überwacht. Mit BACnet besteht eine Schnittstelle, mit der die Klimaanlage nahtlos in die bestehende Leittechnik eingebunden werden konnte, denn die eingesetzte Steuerung von Saia-Burgess Controls hat die BACnet-Funktionalität nach dem BACnet Standard 135-2004 integriert. Anwendungen Solutions Der Paul-Ehrlich-Hörsaal liegt im Campus Charité Mitte. The Paul-Ehrlich auditorium is situated in the hospital campus Charité Mitte. as the control system used, from Saia-Burgess Controls, has the BACnet functionality (BACnet Standard 135-2004) built in. Die Saia-Burgess Steuerung ist als BACnet Broadcast Management Device (BBMD) konfiguriert und kommuniziert mit einer weiteren BBMD im BACnet-Netzwerk der Charité. Es werden 56 BACnet-Objekte zur GLT übertragen. Der Zeitschaltkatalog wurde umgesetzt durch die Anlage eines BACnet-Objekts in der GLT. Über die BACnet-Anbindung sind also nicht nur ein einfacher Datenaustausch zwischen Klimagerät und GLT möglich, sondern auch komplexere Aufgabenstellungen wie Alarmierung und Trendaufzeichnungen. Founded in 1710, the Charité is one of Germany’s oldest and most tradition-rich healthcare institutions. Today, it is also one of Europe’s biggest university hospitals. True to the motto, “Research, Teaching, Healing, Helping”, around 14,000 employees apply themselves to healthcare, science and the training of the next generation of doctors. A new air conditioning system was fitted in the auditorium of the institute for microbiology in 2006. The controller of this system, from Saia-Burgess Controls, was effortlessly connected via BACnet with the existing central building management system at the Charité, which was built by the company TAC. The control concept was developed and implemented by Hansa, a leading company in the air conditioning industry with more than 30 years of experience in the field of air conditioning systems and ventilation. Energy-saving air conditioning systems Air conditioning systems are commonly associated with wasted energy. The opposite is proven by Hansa, which specialises in particularly efficient air conditioning technology for buildings. Precisely in these times of economic pressure, this factor has convinced the Charité to equip its Paul Ehrlich auditorium with Hansa climate technology. In this compact air conditioning system (series HKGKOV-ER-071-S), ambient air is filtered, de/humidified and where required, cooled or heated. Requiring no adjustment to existing room dimensions, the compact systems present an advantage compared with conventional standard models. Innovative control technology With safety considerations in mind, the Charité did not permit the easily realisable remove access to the webtechnology equipped controls. Instead, the control itself provides evidence of energy savings with the aid of the integrated Saia File System. In this process, the relevant energy consumption levels and temperatures, combined with output data of the valves and pumps, is listed in csv fi les. The fi le system is read out and documented at Hansa during every maintenance operation. The data deliver unambiguous information and realise Hansa’s promises based on a high claim to quality. During actual longterm use, the air conditioning system from Hansa requires a convincing 85% percent less electrical energy compared to circulating air cooling systems (including split systems). Data exchange via BACnet One significant stipulation was the integration of the air conditioning with the building control technology already installed on the Charité site. The individual buildings are operated and monitored by a control station from TAC. BACnet creates an interface with which the air conditioning system could be integrated seamlessly with the existing control technology, The Saia-Burgess control system is configured as a BACnet Broadcast Management Device (BBMD) and communicates with an additional BBMD in the BACnet network of the Charité. 56 BACnet objects are transmitted to the building control system. The timeswitch catalogue was implemented via the installation of a BACnet object in the building control system. Therefore, via the BACnet connection not only is an uncomplicated data exchange between air conditioning system and building control system possible, but also more complex tasks such as an alarm system and trend recording. Oliver Greune Product Manager Systemintegrator Business Infrastructure Automation Europe Saia-Burgess Controls AG oliver.greune@saia. burgess.com www.start-controls.com BACnet Europe Journal 8 03/08 37 Anwendungen Solutions Maximale Funktionalität, totale Integration Maximum functionality, total integration Auf einer Gesamtfläche von 225.000 m² vereint Polens kürzlich fertig gestellter Złote Tarasy Komplex im Herzen Warschaus Geschäfts-, Büro- und Entertainmentgebäude. Eine Multikinokette, diverse Shoppingarkaden, Gastronomieeinrichtungen sowie eine Freizeitanlage nehmen 65.000 m² der Fläche ein, weitere 65.000 m² stehen für Büroflächen zur Verfügung. Darüber hinaus erweitert eine Tiefgarage mit 1.700 Parkplätzen den Infrastrukturbereich für die Besucher. Covering a total surface area of 225,000 m2, Poland’s recently completed Złote Tarasy complex in the heart of Warsaw comprises commercial, office and entertainment buildings. A Multikino cinema, restaurants, entertainment centers and shops occupy 65,000 m2 of the space and a further 65 000 m2 is used for offices. An underground accommodates up to 1700 cars. Das Glanzstück von Złote Tarasy ist ein helles, luftiges Atrium – eine mehrstufige Terrasse unter einem Wellglasdach, auf der Besucher verweilen und den Sonnenschein genießen können, sogar in den Wintermonaten. Das moderne Geschäfts- und Freizeitzentrum gilt als das größte Multifunktionsprojekt, das je in Polen realisiert wurde. Aufgrund seiner Größe, der Vielzahl unterschiedlicher Funktionen und dem Anspruch, Gebäudeau- tomation und Sicherheitstechnik nahtlos miteinander zu vereinen, wurde ein System gesucht, das hohe Verfügbarkeit und maximale Integrationsfähigkeit miteinander verbindet. Die eingesetzte Andover Continuum Produktfamilie ermöglicht die gesamte Funktionalität der Liegenschaft, aufgeteilt in zwei unabhängig von einander agierende Systeme, die den „Tower Office“ und den Freizeitkomplex mit 18 Workstati- ons überwachen. Insgesamt 20.000 Datenpunkte integriert die Cyberstation als eingesetzte Leitebene mit folgenden Funktionsbereichen: Lüftung und Klimatisierung (über 40 Fan Coils, 350 Abluftventilatoren sowie Pumpen und weitere Geräte in Unterstationen), Beleuchtung (Steuerung und Kontrolle von mehr als 1.000 Lichtkreisen), Zutrittskontrolle (mit rund 250 Eingängen), Vollständige Integration des Integral Videoüberwachungssystems von TAC mit mehr als 420 Kameras in die Cyberstation Leitebene, Komplette Anbindung und Überwachung des Brandmeldesystems mit über 4.500 Datenpunkten über speziell entwickelte X-Driver in die Continuum Leitzentrale, Überwachung der Kältetechnik durch die Anbindung des Trane-Systems via BACnet/IP, Anbindung des Energiemanagementsystems zur Stromverteilung über Schneider Electric Modicon Controller (TSX PREMIUM), Anbindung von 35 Thyssen Rolltreppen und 45 Kone Aufzügen via ODBC, Integration von drei voneinander unabhängigen Monitoring- und Abrechnungssystemen für anfallende Verbräuche (Wasser, Heizung, Klima, Strom) über eine Ankopplung an den M-Bus. Der kürzlich fertiggestellte Komplex in Polens Hauptstadt gehört gegenwärtig zu den hochkarätigsten Investitionen in Mittel- und Osteuropa. Złote Tarasy vereint Business und Unterhaltung. Złote Tarasy comprise business an entertainment. 38 BACnet Europe Journal 8 03/08 Via BACnet/IP wird die Kältetechnik im Złote Tarasy Komplex in Warschau überwacht. Using BACnet/IP the BMS in Złote Tarasy in Warsaw enables to monitor the refrigeration system. The jewel in Złote Tarasy’s crown is a light, airy indoor courtyard - a multi-level terrace covered with a corrugated glass roof where visitors can, stroll, sit and enjoy the sunshine, even in the winter months. This modern business and entertainment centre represents the largest multi-functional project seen in Poland to date. Due to its size, the variety of different functions it houses and the claim to seamlessly combine building automation and security, the Złote Tarasy complex required a system which could guarantee highest availability and maximum integration capability. The chosen Andover Continuum product family allows the facility’s complete functionality, segmented into two independently acting systems, which monitor and control the “Tower Office” and the entertainment complex with 18 workstations in total. Both systems integrate over 20,000 points from all the buildings’ sub-systems. The integrated system consists of: Ventilation and air conditioning (approximately 40 air handlers and over 350 exhaust fans, pumps and devices in heat and cold distribution substations), Lighting control (control and monitoring over 1000 lighting circuits), Access control (approximately 250 entrances), Total integration of TACs Integral video surveillance system including more than 420 cameras into the Cyberstation Building Management System, Fire alarms: By using a specially developed X- Atrium. Courtyard. driver in the Building Management System, it is possible to monitor 4,500 fi re points, Refrigeration: Using the BACnet/IP data communication protocol the Building Management System enables the user to monitor the refrigeration system. This is in turn controlled by the Trane instrumentation & control system, An electricity management system lets operators read and visualize data captured from the building’s power distribution wiring system, managed by SchneiderModicon controllers of TSX PREMIUM series, Transport: ODBC interfaces were used to input data from 35 Thyssen escalators and 45 Kone lifts to the Building Management System, Connection of three independently working monitoring and settlement systems for utilities con- sumption (water, heating, cooling, electricity) via M-BusMonitoring and settlement system for utilities consumption. The recently completed building complex in Poland’s capital city joins the category of the highest class investments in the Central and Eastern Europe. Marek Olszewski HVAC Team Leader TAC Sp. z o.o. Warsaw Branch marek.olszewski@tac.com www.tac.com BACnet Europe Journal 8 03/08 39 ® Saia BACnet Building Controller Others call it native, we call it innovative. eb W el an -P P eX " / ma fi b u n s E O ce a n D I O L + A L N W o rk M s P -B u s M o d s N u K b X / E IB n e t Saia-Burgess Controls AG Bahnhofstrasse 18 | CH-3280 Murten | Schweiz T +41 26 672 71 11 | F +41 26 672 74 99 www.start-controls.com | pcd@saia-burgess.com r lle ro nt Co n g io in at c ld ct t tifi ui s je en No ct ® B ob je llm e et g er em ob u l o lin s p yst ic D) Cn ) nr Va u r C BA -B nt E of rve ed trie le s am s (F e n (B Eve ng /Se Sch en h fi dy ice / 0 + Cha ent ar o 5 flas ove dev + Cli lend p t on em ign u r e Ca th ng d or + wi ndi an th f e e i Tr at w + Cre D M + BB ro er P lay tion 3 CD Aut o a ®P Sai 7 Inte rn Tel et / In eco tra m net Anwendungen Solutions Fraport testet BACnet Geräte – Wettbewerb auf hohem Niveau Airport tests BACnet Devices – Competition at High Stage Die Fraport AG ließ mit Unterstützung durch die GA Ingenieurgesellschaft mbH und das Ingenieurbüro Pregizer ein eigenes BACnet Testlabor einrichten. Grundlage der Tests sind die individuellen Anforderungen, die der Flughafen an seine Liegenschaften stellt. Die BACnet Konformität wird mit dem BACnet Test Framework getestet, das von MBS entwickelt wurde. Fraport AG, the operating company of Frankfurt Airport, established an own BACnet test laboratory. Supporter were the GA Consulting Engineers and the Consulting Engineer Pregizer. The tests are basing on the individual requirements against the real estate of the airport. The BACnet conformance is tested with the BACnet Test Framework, designed by MBS. Als im Jahr 2002 im Zuge geplanter Ausbauten am Flughafen Frankfurt Main die Situation der Gebäudeautomation betrachtet wurde, stellte sich folgende Ausgangssituation dar: zwei unterschiedliche, getrennte Systeme eines einzelnen Herstellers, proprietäres Datenkommunikationsprotokoll, weit über 200.000 Datenpunkte, kein Wettbewerb in der Gebäudeautomation möglich. Als eines der primären Ziele für zukünftige Projekte am Flughafen wurde die Schaffung von Wettbewerb im Bereich der Gebäudeautomation auf Basis eines neutralen, offenen Datenkommunikationsprotokolls festgelegt. Um dieses Ziel zu erreichen, wurde nach intensiven Recherchen und Diskussionen in verschiedenen Bereichen der Fraport AG BACnet als geeignetes Datenkommunikationsprotokoll ausgewählt. Da BACnet eine gewisse Wahlfreiheit in der Umsetzung innerhalb des Protokolls durch die einzelnen Hersteller zulässt, ist auch bei bestehender BACnet Konformität eine volle Interoperabilität verschiedener Hersteller im Funktionsverbund nicht automatisch gegeben. BACnet für Großflughafen Eine Untersuchung bei der Fraport AG ergab, dass die besonderen Anforderungen eines Großflughafens an die Gebäudeautomation innerhalb der normativen Vorgaben der GA-Weltnorm mit dem BACnet Datenkommunikationsprotokoll realisiert werden könnten. Diese Anforderungen wurden in einem umfangreichen GALastenheft zusammengestellt und ausführlich beschrieben. Zum Zeitpunkt der Entscheidungsfi ndung gab es weltweit keine Möglichkeit, die geforderten BACnet-Funktionalitäten mit einem vertretbaren und reproduzierbaren Aufwand zu prüfen und zu dokumentieren. Lediglich manuelle Tests mit großem Zeit- und Kostenaufwand und mit eingeschränktem Funktionsumfang standen zur Verfügung. Die Fraport AG entschied sich darauf hin für einen innovativen und zukunftsweisenden Weg und ließ mit externer Unterstützung durch die GA Ingenieurgesellschaft mbH und das Ingenieurbüro Pregizer ein eigenes BACnet Testlabor einrichten, in dem mit einem innovativen Testverfahren die BACnet Konformität und die speziellen liegenschaftsspezifischen Anforderungen gemäß dem GA Lastenheft mit vertretbarem Aufwand getestet werden sollten. Mit der praktischen Durchführung der Prüfungen im Testlabor wurde die MBS GmbH, Krefeld beauftragt. Das war die Geburtsstunde des „BACnet Test Framework“, einer Software, die für diesen Zweck von MBS entwickelt wurde. Ziel der Testsoftware sollte die Ermöglichung einer automatisierten Prüfung der Konformität zum BACnetProtokoll sein – inklusive aller optionalen Eigenschaften von Geräten verschiedener Hersteller für Gebäudeautomationssysteme, die das BACnet-Protokoll verwenden. Zusätzlich wurden Möglichkeiten zur Durchführung von Interoperabilitäts- und Performance-Prüfungen realisiert. Mit einem zunächst begrenzten, aber langfristig erweiterbaren Kreis von Bietern wurden Geheimhaltungsund Kooperationsvereinbarungen geschlossen mit dem Ziel, die Projektanforderungen gemäß dem GA-Lastenheft in ihren Produkten umzusetzen. Zur Prüfung wurden von den Herstellern Testeinheiten bereitgestellt. Erweiterter Funktionsumfang Diese Testeinheiten wurden im Testlabor mit dem BACnet Test Framework auf Einhaltung der Konformität, in gemeinsamen Testrunden mit allen Herstellern auf Interoperabilität untereinander sowie auf Performance im FraportNetzwerk untersucht. Das BACnet Test Framework wird mittlerweile ebenfalls für die Zertifi zierungsprüfungen im europäischen Testlabor WSPLab in Stuttgart eingesetzt. BACnet Europe Journal 8 03/08 41 Anwendungen Solutions Durch die automatisierten Testverfahren ist es nun in bisher nicht erreichbarer Vollständigkeit und Schnelligkeit möglich, die Eigenschaften von BACnet Geräten zu erkennen und zu analysieren. Dies hat schon jetzt auch außerhalb des Frankfurter Flughafens zur Beschleunigung der BACnet-Umsetzung und Weiterentwicklung beigetragen. Dadurch werden in vermehrtem Maße BACnet Geräte zur Verfügung stehen, welche mit erweitertem Funktionsumfang bereits getestet und zertifi ziert sind. Jede größere Liegenschaft kann auf dieser Basis künftig liegenschaftsspezifi sche BACnet-Anforderungen auswählen und diese mit vertretbarem Aufwand normkonform überprüfen lassen. Dadurch wird erstmals „echter“ Wettbewerb mit BACnet auf einem hohen Standard ermöglicht. In 2002 during scheduled expansions at the Airport Frankfurt/Main, the situation in building automation was as follows: two different and separated systems of one single manufacturer proprietary communication protocol more than 200.000 datapoints no business competition in building automation possible As the primary intention for future building automation projects at the airport, establishment of business competition based on a neutral, manufacturer-independent and open data-communication protocol was specified. To succeed, BACnet was chosen as the appropriate data communication protocol after intensive research and internal discussions at different departments of Fraport AG. Due to the fact, that BACnet allows the freedom to choose certain functionality from the standard by manufacturers, a full interoperability of all functions between devices from different manufacturers cannot be expected by nature. BACnet for major airports A research by Fraport AG showed, that the special requirements of major airports in terms of building automation will be fulfilled using the world-wide norm BACnet. Those requirements were documented in an extensive functional specification for the building automation in future projects. But, at the time of this decision, it was not possible to test and document the specified and required BACnet functionality with appropriate and reproducible effort. Only manual tests with limited functionality range were available causing huge effort for manual testing. Fraport AG decided for an innovative and trend-setting approach and established an own test laboratory with external support by GA Consulting Engineers and Consulting Engineer Pregizer. The test laboratory was intended to establish innovative test methods to test the BACnet conformance and facility-specific requirements to building automation components with acceptable effort. The order to perform 42 BACnet Europe Journal 8 03/08 the practice tests in this test-laboratory was given to MBS, Krefeld. For this purpose, MBS developed the software “BACnet Test Framework”. Objective of this test software was enabling automated conformance testing of BACnet components including all optional properties of devices from different manufacturers. Additionally methods for testing the interoperability and performance of devices were developed. With a limited, but in future extendable number of manufacturers non-disclosure and cooperation-contracts were signed to achieve the project requirements specified in the functional specifications. For the testing purpose, the manufacturers provided test equipment to the laboratory. Enhanced scope of operation This test equipment was tested on conformance to BACnet using the BACnet Test Framework. In workshops with all manufacturers, the interoperability of the provided devices was tested as well as the performance within the Fraport network. Meanwhile, the BACnet Test Framework is used as the official test-tool of the European test laboratory WSPLab, Stuttgart as reported in earlier issues of this journal. Due to the automated test methods, testing the properties and conformance of BACnet devices can now be performed in integrity and rapidness, which was not possible up to now. Additionally, this fact already lead to speeding-up BACnet realizations and development of BACnet devices outside the scope of Fraport and Airport Frankfurt/Main. In the future more and more tested and certified BACnet implementations with enhanced functionality will be available on the market. On this basis, each larger facility may test their specific requirements on BACnet in the future with acceptable effort according to the norm. For the fi rst time, this allows “real and fair” business competition with BACnet at high stage. Bernd Hanke Head of Airport Facility Management Fraport AG Günter Meyer Head of Engineering Planning and Project Management Fraport AG Thomas Kohlhoff Managing Partner GA Ingenieurgesellschaft mbH Marius Hartel Managing Partner GA Ingenieurgesellschaft mbH Volker Pregizer Owner Consulting Ingenieurbüro Pregizer Frank Schubert MBS GmbH frank.schubert@ mbs-software.de www.mbs-software.de Anwendungen Solutions BACnet Test Framework an der FH Dortmund University of Applied Sciences and Arts Dortmund meets BACnet Test Framework An der Fachhochschule Dortmund wird eine Gruppe von Studierenden im Rahmen einer Projektarbeit umfangreiche Recherchen und Arbeiten zur Software BACnet Test Framework (BTF) durchführen. At the University of Applied Sciences and Arts Dortmund a group of students will perform extensive researches and workings on the software BACnet Test Framework (BTF) within a semester work. Die Software BACnet Test Framework wurde als europäisches Testtool ausgewählt und ist seit der ersten automatisierten Testrunde für BACnet-Geräte im europäischen Testlabor WSPLab, Stuttgart im Einsatz. Im Januar wurde die Installation der Software im Labor für Prozessoren und Bussysteme des Fachbereichs Informations- und Elektrotechnik der Fachhochschule Dortmund vorgenommen. Im Rahmen eines kurzen Workshops wurden die Studenten gründlich in die praktische Arbeit mit der Software eingeführt. Hierzu war Frank Schubert von der Herstel- lerfi rma MBS GmbH aus Krefeld anwesend und erarbeitete mit den an diesem Projekt beteiligten Studierenden die grundlegenden Vorbereitungen zur Arbeit mit der Software, angefangen bei der Installation, über die Einrichtung der Testumgebung für ein BACnet-Gerät bis hin zu ersten Testläufen. Im Rahmen der Projektarbeit sollen praktische Erfahrungen mit der automatisierten Prüfung von BACnetGeräten gesammelt werden. Mit Hilfe der integrierten Programmierschnittstelle des BACnet Test Framework lassen sich jedoch auch Ideen wie ein Electronic Protocol Conformance Statement (EPICS-) Generator realisieren. Die Projektarbeit wird einen Umfang von zwei Semestern haben. Darüber hinaus sind weitere Projekt- oder Diplomarbeiten geplant. Das BTF an der FH Dortmund. V. l. n. r.: Frank Schubert (MBS), Prof. Peter Fischer (FH Dortmund), Stephani Damaica, Dominik Obermeyer, Zhihao Liu (Studenten). The BTF at the University of Applied Sciences and Arts Dortmund. From left to right: Frank Schubert (MBS), Prof. Peter Fischer (University), Stephani Damaica, Dominik Obermeyer, Zhihao Liu (students). The software BACnet Test Framework was chosen as the European test-tool and is currently used in the first automated testround for BACnet devices at the European test-laboratory WSPLab in Stuttgart. On January, 8th the software was installed in the laboratory for processors and bus systems of the department for information technology and electrotechnique at the University of Applied Sciences and Arts, Dortmund. During the installation a workshop was made for the basic introduction to the practical work with the software. For this Frank Schubert from the manufacturer company of the software MBS, Krefeld and the group of students (see picture below) took the first practical steps in using the software to test BACnet devices. Within this semester work experiences in automated testing may be researched. Using the programming interface of the software additionally ideas like an EPICS-Generator (EPICS= EPICS=Electronic Protocol Conformance Statement) can also be realized. The semester work will have a length of approx. 2 semesters, further semesterworks or Diploma thesis are intended. Prof. Peter Fischer Faculty of Communications Engineering University of Applied Sciences and Arts Dortmund fischer@fh-dortmund.de BACnet Europe Journal 8 03/08 43 Systemintegration mit diversen Herstellern BACnet ● ist die zukunftsweisende Lösung für intelligente Gebäudesysteme ● bietet das einheitliche, herstellerübergreifende Management aller Systemebenen ● wirkt kostensenkend durch Synergieeffekte Mit BACnet dem Markt einen Schritt voraus. SWG Stuckmann Wirtschaftliche Gebäudesysteme GmbH Schinkelstraße 78 Telefon 0 25 21/8 27-0 www.swg-beckum.de 59227 Ahlen Telefax 0 25 21/8 27-2 49 info@swg-beckum.de networking|together© ICS – InlineControlServer Modular 32-Bit Control Station BACnet/IP, LONMARK TP/FT-10; opt. IP-852, DALI Webserver, Alarm, Trendlog, Scheduling, E-Mailing Embedded Visualization / LNS Plugins More details at light+building and at Niagara Summit SysMik at booth 9.1 E10 and 9.1 B59 Frankfurt am Main / 06. - 11. April 2008 May 4 - 6; Saddlebrook Resort - Tampa sysmik©2008 8 sysmik.com Anwendungen Solutions Kommandopriorisierung mit BACnet Command Priorization with BACnet In vielen Anwendungen der Gebäudeautomation spielt die Priorisierung von Kommandos eine wichtige Rolle. Beispielsweise ist es bei Wartungsarbeiten lebenswichtig, dass andere Prozesse wie Zeitschaltprogramme unterdrückt werden, solange in der Anlage gearbeitet wird. In many applications in building automation command priorization is important. For example for service access it is important to suppress processes like schedule programs while working. Für die so genannten kommandierbaren Objekte (also analoge, binäre und mehrstufige Ausgangs- und Werteobjekte) beschreibt der BACnet-Standard, wie die Priorisierung erfolgt. Die Priorisierung wird mit zwei Eigenschaften im Objekt selbst gespeichert. Hierfür gibt es zunächst den Automatikwert (Eigenschaft Relinquish-Default), der immer dann greift, wenn kein anderer höher priorisierter Wert geschrieben wurde. Neben dem Automatikwert sieht der BACnet-Standard 16 Prioritätsstufen (1=höchste, 16=niedrigste Priorität) vor, die unterschiedlichen Prozessen aber auch unterschiedlichen Benutzern zugeteilt werden können (Eigenschaft Priority Array). Soll ein Wert geschrieben werden, so wird gleichzeitig immer die Prioritätsstufe mit angegeben (Vorgabewert ist Stufe 16). Der jeweils höchste priorisierte Wert greift dann auch in die Anlage durch (d.h. wird z.B. auf den Ausgang geschrieben). Wird ein Wert auf einer niedrigeren Priorität geschrieben, so greift dieser nicht in die Anlage durch, solange noch ein höher priorisierter Wert vorhanden ist. Um den Wert wieder zurück zu nehmen, wird programmtechnisch die Konstante NULL auf die jeweilige Priorität geschrieben, was dazu führt, dass der vorherige Wert gelöscht und die nächst niedrigere Priorität durchgreift. Eine Besonderheit stellt die Prioritätsstufe 6 dar, diese ist für minimale Einschaltund Ausschaltzeiten reserviert und darf in keinem Fall von außen beschrieben werden. BACnet schreibt für bestimmte Prioritätsstufen die Bedeutung vor (z.B. 1= Manual Life-Safety, 8= Manual Operator), andere Prioritätsstufen sind im Projekt frei defi nierbar. Wichtig ist, dass nicht mehr benötigte Prioritäten (z.B. nach einem Serviceeinsatz) auch wieder gelöscht werden, da niedriger priorisierte Bediener ansonsten keine Chance haben, Werte zu verändern. Wird im Projekt keine Kommandopriorisierung benötigt, so können alle Prozesse die gleiche Priorität verwenden (z.B. 8 = Manual Operator), was dazu führt, dass immer der letzte Zugriff „gewinnt“. For the so-called commandable objects (analog, binary and multi-state output and value objects) the BACnet standard clearly describes the mechanisms of priorization. The priorization is stored within the object using two properties. The automatic value (property Relinquish Default) is used, when no other (higher) value was written to the object. Beyond the automatic value BACnet allows 16 levels for priorization (1=highest, 16=lowest), which can be assigned to certain processes or user levels (property Priority Array). external processes. The meaning of certain priority levels is defi ned in the BACnetstandard (e.g. 1= Manual Life-Safety, 8= Manual Operator), others can freely be defined in projects (Available). It is quite important to release values which are no longer required (e.g. after a service access) to allow lower priorized users the access to the objects again. If priorization of any kind is not required in a project, all processes may have the same priority (e.g. 8 = Manual Operator), which results in “last wins”. If a value is written to the object, the priority is given in the write-command (Default-Priority is 16). Only the highest value within the priority array is written to the output. If a value with a lower priority is written, it will not be written to the output as long as a higher priorized value exists. To erase a value from the priority array, the NULL constant is written to the object at the designated priority level, which leads to the next lower value to become active. The priority 6 is reserved for minimum on- and off-times and shall never be written by Frank Schubert ppa. Sales Manager MBS GmbH frank.schubert@ mbs-software.de www.mbs-software.de BACnet Europe Journal 8 03/08 45 Produkte Products BACnet/IP Building Controller frei programmierbar Freely programmable BACnet/IP Controller Im Frühjahr wird das in der Industrie- und Gebäudeautomation erfolgreiche WAGO-I/O-SYSTEM 750 um den BACnet/IP-Controller 750-830 erweitert. This spring, the 750-830 BACnet/IP Controller will join the WAGO-I/O-SYSTEM 750, which has been very successful in the industrial and building automation sectors. Der WAGO BACnet/IP-Controller 750-830 repräsentiert das Geräteprofil des BACnetBuilding-Controllers (B-BC). Konzipiert als frei programmierbares Gerät, kann er eine Vielzahl verschiedener Gebäudeautomations-, Steuerungs- und Regelungsaufgaben übernehmen. Der Controller bietet sowohl Client-, als auch Serverfunktionalität. Controller geladen werden. Zur Unterstützung der Anwender stehen Bibliotheken, zum Beispiel für HLK-Anwendungen mit integrierten Visualisierungselementen, zur Verfügung. Dafür ist im Controller ein interner WEB-Server vorhanden, auf dem HTMLSeiten für die webbasierten Anwendungen hinterlegt werden können. Bei der Anwendung als BACnet Native Server erkennt der Controller automatisch alle angesteckten digitalen und analogen E/A-Baugruppen und erstellt daraus BACnet-Objekte. Danach können mit dem kostenlosen WAGO Tool „WAGO BACnet Configurator“ die BACnet-Objekte aus dem Controller ausgelesen und gegebenenfalls modifiziert werden. Auch BACnetGeräte anderer Hersteller kann man mit diesem Tool einbinden. Als Schnittstelle zu KNX TP1-Netzwerken kann eine WAGO KNX/EIB/ TP1-Klemme an den BACnetController gesteckt werden. Mit der WAGO IEC-Programmiersoftware (WAGOI/O-PRO CAA) können darüber hinaus eigene Applikationen erstellt, BACnetObjekte erzeugt und in den BACnet/IP-Controller 750-830. The WAGO 750-830 BACnet/ IP Controller represents the device profile for the BACnet building controller (B-BC). Designed as a freely programmable device, this controller can perform a variety of building automation, control and regulating tasks, offering both client and server functions. When used as a BACnet native server, the controller automatically detects all digital and analog I/O modules connected to the system and generates the corresponding BACnet objects. Using WAGO IEC programming software (WAGO-I/OPRO CAA), it is also possible to create dedicated applica- tions and generate BACnet objects that can be loaded into the controller. Libraries (e.g., for HVAC applications with integrated visualization elements) are available to support users. Furthermore, the controller features an internal server on which HTML pages can be placed for use in Web-based applications. Using the „WAGO BACnet Configurator“ tool, BACnet objects can be read out from the controller and modified if necessary. BACnet devices from other manufacturers may also be integrated with this tool. A WAGO KNX/ EIB/TP1 module may be connected to the BACnet controller to interface with KNX TP1 networks. WAGO Kontakttechnik GmbH & Co. KG info@wago.com www.wago.com 46 BACnet Europe Journal 8 03/08 Produkte Products Deltas Fenster in die BACnet Welt Delta’s Window to the BACnet World Das Delta HMI (Human Maschine Interface) ist ein 7 Zoll Farb-Touchscreen und wird für die Visualisierung eines BACnet Gebäudeautomationssystems eingesetzt. The Delta HMI is a 7 inch colour touchscreen HMI (Human Machine Interface) used for interfacing with BACnet building automation systems. Das Delta HMI nutzt BACnet über Ethernet, um mit den DDC Controllern zu kommunizieren. Mit frei gestaltbaren 3D-Grafiken lassen sich kundenspezifische und anwenderfreundliche Applikationen erstellen. Applikation Das Delta HMI ermöglicht Bedienern, HLK- und Gebäudeautomationssysteme wie zum Beispiel Lüftungsanlagen, Kessel, Kälteanlagen, Beleuchtungssteuerung, Zutrittskontrolle und Sicherheitsgewerke mittels Echtzeit-Grafi k zu überwachen und zu verwalten. Das HMI kann auf der Wand oder im Schaltschrank montiert wer- den und ermöglicht es, Zeitpläne, Alarme und Trendlogs von Lüftungs-, Heizungsund Kühlanlagen und andere mechanische Einrichtungen zu überwachen und zu verändern. Das Delta HMI kann als Schnittstelle verwendet werden, um sehr einfach die Raumbelegung, den Temperatursollwert zu ändern und einen Lageplan zu visualisieren. Eigenschaften 7 Zoll Farbtouchscreen, attraktives, modernes Design, Kundenspezifi sche Grafi ken können direkt mit Deltas Illustrator erstellt werden, Überwachen und Steuern von BACnet Objekten sowie Eingängen, Ausgängen und Variablen, Modifizieren von BACnet Objekten wie Zeitpläne und Kalender, Alarme anzeigen und bestätigen, Sollwerte ändern, Ein- und Ausgänge überwachen, Multiuser Kennwörter für restriktive Zugriffsteuerung, einstellbare Zeitspanne für Hintergrundbeleuchtung, unterstützt BACnet über Ethernet-Kommunikation, Firmware kann über das Netzwerk geladen werden, Gestaltet für Schaltschrank- und Wandmontage, für Neubau- und Sanierung. The Delta HMI uses BACnet over Ethernet to communicate with controllers on a local area network. User created, 3D animated graphics allow the HMI to be completely customized for your specific application. Application The Delta HMI allows occupants to monitor and manage a building’s systems, such as air handlers, boilers, chillers, lighting, access and security. Systems and floor layouts can be monitored and adjusted, including temperature setpoints, schedules, calendars HMI Touchscreen Bediendisplay. HMI Touchscreen operator interface. and alarms. The Delta HMI is suitable for panel mounting in mechanical rooms, and also has a design quality that makes it appealing for use as a small building interface, mounted in public spaces, such as a reception area. Features 7 inch colour Touchscreen interface, Attractive, modern design to install in any location, Create custom 3D graphics using Delta Control’s Illustrator drawing tool, Monitor and command BACnet objects such as Inputs, Outputs and Variables, Modify BACnet objects such as schedules and calendars, Display and acknowledge alarms, Change system setpoints, Multiple users and passwords for restricting access, Adjustable backlighting timeout, Supports BACnet over Ethernet communications Designed for mounting in Panel, wall, new and retrofit locations, Firmware can be fl ash loaded over the network. Delta Controls Germany Ltd. dlukanic@deltacontrols.de www.deltacontrols.de BACnet Europe Journal 8 03/08 47 Produkte Products Natives BACnet mit der 'Wonderware System Platform' Native BACnet with the Wonderware System Platform Die 'Wonderware System Platform' ist eine flexible, skalierbare, objektorientierte Softwareplattform, die die Anforderungen des Managements von Liegenschaften aller Größen oder geografischen Verteilung erfüllt. The Wonderware System Platform is a flexible, scalable and object-orientated Software platform suited to fulfill all facility management requirements, regardless of size or geographical distribution. Mit der 'Wonderware System Platform' können nun die Vorteile der Objektorientierung des BACnet voll genutzt werden. Das von der Fa. Munich Software für die System Platform angebotene MSP BACnet Integration Package (kurz MSP BACnet) ermöglicht die automatische Konfiguration eines BACnetProjektes in der System Platform. Dieses Paket besteht aus den folgenden Komponenten: BACnet Application Generator – automatische/interaktive Applikationserstellung, DASBACnet Server – nativer BACnet Datenserver. Zur Konfiguration werden alle Teilnehmer eines BACnet-Netzwerkes eingelesen und wahlweise die in den Devices verwendeten Objekte oder die Devices selbst mit ihren Properties automatisch in der 'System Platform' als Objekt angelegt. Veränderungen an der BACnet-Konfiguration können später jederzeit neu synchroniert werden. Für den Systemintegrator bietet MSP BACnet: Integration der Konfiguration, Integration der Datenerfassung, Objektabbildung im Modell, Eingebaute Diagnose. Mit der 'System Platform' ist somit eine volle und herstellerneutrale Durchgängkeit zwischen der Automationsund Managementebene gewährleistet. Dies ermöglicht sowohl den Systemintegratoren wie auch Nutzern enorme Vorteile: Remotefunktionalität für Entwicklung, Administration und Wartung, Strukturierter Ansatz durch Objektvorlagen und Vererbung, Sicheres Änderungsmanagement durch integrierte Datenbank und Versionsverwaltung, Standardisierungsmöglichkeiten, Geringe Erstellungs- und Wartungskosten, Investitionssicherheit, Flexible Erweiterbarkeit. The Wonderware System Platform makes full use of all advantages that are part of the object-oriented structure of BACnet. The MSP BACnet Integration Package (MSP BACnet) developed by “Munich Software“ for the System Platform facilitates the automatic configuration of a BACnet application project within the System Platform. This package consists of the following components: BACnet Application Generator – automatic/interactive application development DASBACnet Server – native BACnet Data server The application generator scans all BACnet devices on the bus and generates the corresponding objects in the System Platform as well as the attributes, properties and IO configuration associated with it. Future changes of the BACnet devices and topology can easily be synchronized and updated. The MSP BACnet offers system integrators: Integrated configuration Integrated data collection Model-based object representation Built-in diagnostics The Wonderware System Platform is an open and independent platform that supports complete communication between the automation and management level. This encompasses various valuable benefits for system integrators as well as users: Remote functionality for development, administration and maintenance Logical and structured approach based on objecttemplates and derivation Integrated database and administration of version history for secure change management Standardization Low development and maintenance costs Protection of investment Scalability BACnet Integration mit der 'Wonderware System Platform'. BACnet integration with Wonderware System Platform. 48 BACnet Europe Journal 8 03/08 Wonderware GmbH gero.kura@ wonderware.com www. wonderware.com Produkte Products Objektorentiertes System für offene Lösungen Object-oriented System for Open Solutions Das Automationssystem DDC4000 von Kieback&Peter ist mit nativem BACnet offen für unabhängige, gewerkeübergreifende Lösungen. With native BACnet on board the Kieback&Peter DDC4000 automation system is open to independent, cross-functional solutions. Die gesamte Kommunikation zwischen den Systemkomponenten basiert auf BACnet. BACnet unterstützt auch den Datentransfer zwischen dem DDC4000-System und der Gebäudeleittechnik Neutrino-GLT. Objektorientierte Systeme Die Software verschafft dem DDC4000-System zusätzliche Flexibilität. Parametrierbare Objekte erfüllen vielfältige, beliebig kombinierbare Steuerungs- und Regelungsaufgaben. Die Aufgaben können online aktiviert und mit Kennwerten versehen werden. Die Software steuert auch Modems an und unterstützt den Versand von Fax und E-Mails. Einfache Bedienung Über einen farbigen Touchscreen hat der Nutzer „hautnahen“ Kontakt zu seinen Anlagen. Er sieht sofort, was läuft – über gut verständliche Bedienmenüs, skalierbare Anlagenbilder und Trendanzeigen. Er kann alles einfach per Fingertipp bedienen – unterstützt durch Informationsgrafi ken, die mit einem Blick erfasst werden können. Trendkurven schaffen Transparenz und erleichtern die Optimierung. TCP/IP, Webservices Die Kommunikation erfolgt über TCP/IP. Vorhandene Infrastrukturen in Gebäuden und Liegenschaften können genutzt werden. Webservices werden über den Internet Explorer einfach in das System integriert. So können die Automationsstationen fernbedient werden. Störmeldungen werden per E-Mail versendet. The entire communication between the system components is based on BACnet, which also supports the data transfer between the DDC4000 system and the Neutrino-GLT central building control system. Object-oriented Systems The software gives the DDC4000 system additional flexibility. Parameter-driven objects can carry out any combination of various control tasks. The tasks can be activated online and tagged with variables. The software also drives modems and supports fax and e-mail communication. Easy to operate With a colored touch screen the user has direct contact to Automationsstation DDC4200 mit Touchscreen. Automation Station DDC4200 with touchscreen. the system and can immediately see what is working – via easily understandable menus, scalable installation graphs and trend displays. All operations are literally at his fingertips – supported by information visuals, which can be captured at a glance. Trend curves provide for transparency and facilitate optimization. Web services are easily integrated into the system via Internet Explorer. This way the automation stations can be remotely controlled and fault reports sent by e-mail. TCP/IP, Web Services The DDC4000 automation stations communicate via TCP/IP. Existing infrastructures in the buildings can also be used. Kieback&Peter GmbH & Co. KG info@kieback-peter.com www.kieback-peter.de BACnet Europe Journal 8 03/08 49 For freedom of choice, flexibility and independence: choose Priva. Anders Norén Managing Director Priva Building Intelligence Ltd. Priva, a leading national and international specialist in building management systems. As a facilities manager, building manager or building owner, you are well aware of the importance of a future-proof, energy efficient and cost effective building management system. Flexible modular applications and guaranteed independence thanks to a network of reliable and expert installers, and total freedom of choice when integrating and interfacing with third-party applications. Whether your goal is to reduce carbon emissions and costs or increase comfort and user convenience, Priva’s intelligent technology allows you to optimise all aspects of your building management system without outside assistance. Are you looking for a building management system that provides freedom of choice, flexibility and independence? If so, Priva is the best choice. The art of having control Priva Building Intelligence | Postbus 18 | 2678 ZG De Lier | T +31 (0)174-522 600 | F +31 (0)174-522 700 | sales.building@priva.nl | www.ikkiesvoorpriva.nl room automation X-RUS – a new generation of room automation schön klein kompatibel smart small compatible Modernes Design modern design Einfache Montage easy to install Optimale Energieeffizienz ideal energy efficiency Reduzierte Brandlasten reduced thermal load Flexibles System: wenige Gerätetypen, für alle Raumautomationsaufgaben Flexible system: only few components to meet all challenges of room automation Individuelles Wohlfühlklima We’ll regulate that for you. Controller X-RUS1.0 SE-Elektronic GmbH Eythstr. 16 · D-73037 Göppingen just feel comfortable Tel. +49 (0) 7161/ 95 84 - 0 Fax +49 (0) 7161/ 95 84 - 45 Internet: www.se-elektronic.de BACnet MS/TP inside – open to communicate Produkte Products Neue BACnet Automationsstationen New Automation Stations for BACnet SAUTER stellt auf der Light+Building die neue Systemfamilie EY-modulo vor: Automationsstationen für Gebäude- und Raumautomation - komplett, modular, basierend auf BACnet/IP mit integrierter Web Technologie. At the Light+Building exhibition, SAUTER presents its new EY-modulo family of systems: automation stations for building and room automation - complete, modular and based on BACnet/IP with integrated web technology. Die BACnet Automationsstation modu525 und der BACnet Raumautomationsregler ecos 502 sind aus der Familie EY-modulo 5 mit nativem BACnet/IP. Die modu525 ist eine modulare Automationsstation, zugeschnitten auf die heutigen und zukünftigen Anforderungen der Gebäudeautomation und der primären Energieaufbereitung (HLK). Mit dem Raumautomationsregler ecos502 dringt BACnet/ IP erstmals in die Raumautomation vor. Die konsequente Verwendung von IP-Technologie erlaubt den reibungslosen Datenaustausch der Raumautomation mit der Primäranlage. Der Building Controller basiert auf einer modularen Struktur, so dass die Bedürfnisse einer Anlage flexibel mit I/O Modulen angepasst werden können. Ein ausgeklügeltes, großzügiges Beschriftungskonzept erlaubt den sicheren Anlagebetrieb vor Ort. Mit Kommunikationsmodulen moduCom kann die modu525 für die Integration von FeldbusSystemen wie Modbus/RTU, M-Bus usw. in BACnet/IP eingesetzt werden. Die Automationsstation modu525 wurde beim akkreditierten BACnet Testlabor (WSPLab) für den BACnet Konformitätstest eingereicht. Zusätzlich zur nativen BACnet Funktionalität verfügt die modu525 über einen integrierten Web Server, der die vollständige Visualisie- The building controller has a modular structure, so that the requirements of an installation can be met flexibly using I/O modules. A clever and generous method of inscription facilitates operation on site. With moduCom communication modules, the modu525 can be used to integrate field-bus systems such as Modbus/RTU, M-Bus etc. in BACnet/IP. Automationsstation modu525 und Raumautomationsregler ecos 502 (EY-modulo 5 Familie). Automation station modu525 and ecos 502 room automation controller (EY-modulo 5 Family). rung, Bedienung, Analyse und Alarmierung der Objekte mit einem Standard-Internet-Browser erlaubt. Die Visualisierung und Bedienung erfolgt hierbei über speziell für PC oder mobile Clients optimierte Web-Seiten. Innovativ wurde für die strukturierte Darstellung der Anlagen das „Structured View“ Objekt aus dem Addendum d des BAC-netStandards 135-2004 verwendet. Mit diesem integrierten moduWeb erhalten Sie somit jederzeit Zugriff auf die Anlage - vom Schaltschrank oder per Fernzugriff, über das lokale Netzwerk oder das Internet. At the Light+Building Fair Frankfurt, SAUTER will be unveiling its EY-modulo system: the modu525 BACnet automation station and the ecos502 BACnet room automation controller from the EY-modulo 5 family with native BACnet/IP. The modu525 is a modular automation station, tailored to the present and future demands of building automation and of primary energy processing (HVAC). With the ecos502 room automation controller, BACnet/IP is advancing into room automation systems for the first time. The resolute use of IP technology enables data from the room automation system to be exchanged readily with the primary installation. The modu525 automation station was submitted to WSPLab, an accredited BACnet testing laboratory for the BACnet conformity test. In addition to the native BACnet functionality, the modu525 has an integrated Web-Server that provides full visualisation, operation, analysis and alerting using a standard internet browser. Visualisation and operation are performed on web pages designed specially for PC or mobile clients. As an example of innovative thinking, the ‚structured view‘ object (from the addendum d to the BACnet standard 135-2004) is used to portray the structure of the installations. This integrated moduWeb provides access to the plant at all times – either from the motor control centre or by remote access via the local network or the internet. Fr. Sauter AG info@ch.sauter-bc.com www.sauter-controls.com BACnet Europe Journal 8 03/08 51 Produkte Products Universal-Gateway Compact: Der Schlüssel zur Integration The Key to Integration: Universal-Gateway Compact Die MBS GmbH aus Krefeld stellt zur Messe light+building 2008 die neue Produktlinie „Universal-Gateway Compact“ vor. At the fair light+building 2008 MBS, Krefeld introduces the new product-line „Universal-Gateway Compact“. Mit der neuen Produktlinie „Universal-Gateway Compact“ wird das Portfolio der bekannten und bewährten MBS Universal-Gateways nach unten abgerundet. Die Geräte sind mit USB-, Ethernet- sowie 2xRS232 und 1xRS485-Schnittstellen ausgestattet. Zur Überwachung sind ein interner Temperatursensor sowie ein Schaltausgang mit 1250W Anschlussleistung vorhanden. Das Gerät wird im Schaltschrank auf DIN-Hutschienen montiert. Der Spannungsanschluss ist als variabler AC/DC-Anschlussausgeführt und erlaubt den Anschluss an eine Vielzahl möglicher Spannungsquellen. Als Kommunikationsprotokolle steht eine Vielzahl offener und frei verfügbarer, aber auch hersteller-spezifischer Protokolle zur Verfügung. Als Besonderheit stehen BACnet-seitig erstmals vier der sechs möglichen Medien zur Verfügung: BACnet Ethernet (ISO8802-3) BACnet/IP nach Annex-J (inkl. BBMD und FDFunktionalität) BACnet/PTP über Modem BACnet/MSTP über RS485 Als weitere offene Protokolle stehen unter anderem Modbus (seriell und TCP/IP), EIB/ KNX, IEC 60870, ESPA 4.4.4, OPC-Data Access und viele mehr zur Verfügung. Die Konfiguration erfolgt mit Hilfe der enthaltenen kostenfreien Transfersoftware oder alternativ über den integrierten Webserver. Umfangreiche Diagnosefunktionen erlauben die Untersuchung der Kommunikation auf den angeschlossenen Schnittstellen. Mit dem Universal-Gateway Compact steht eine insbesondere für kleine Applikationen geeignete Lösung für die Integration verschiedener Kommunikationsaufgaben zur Verfügung. Die Geräte sind ab Jahresmitte 2008 verfügbar. Der Universal-Gateway Compact Universal-Gateway compact The new product-line „Universal-Gateway Compact“ completes the portfolio of well-known and approved Universal-Gateways. The devices provide USB-, Ethernet- as well as 2xRS232 and 1xRS485-interfaces. For external observation, an additional temperature-sensor and a relay switching output with 1250W connecting load are integrated. They are mounted to the cabinet using the integrated DIN rail mounting. The connection voltage offers a wide range of variable AC/DC power supply. The supported communication protocols cover proprietary protocols as well as open and freely available protocols. BBMD and FD-functionality) BACnet/PTP over Modem BACnet/MSTP over RS485 Further protocols are e.g. Modbus (serial and TCP/IP), EIB/KNX, IEC 60870, ESPA 4.4.4, OPC-Data Access and many more. For configuration purposes, the free-of-charge transfersoftware or the internal web-server may be used. Extensive diagnosis-functions allow detailed diagnosis on the connected interfaces. The „Universal-Gateway Compact“ products provide a qualified solution, especially for smaller integrations of communication tasks. The product will be available midyear 2008. As a special feature, 4 of the 6 available BACnet layers are supported: BACnet Ethernet (ISO8802-3) BACnet/IP Annex-J (incl. MBS GmbH frank.schubert@ mbs-software.de www.mbs-software.de BACnet Europe Journal 8 03/08 53 Produkte Products Extrem flexibel und reich an Funktionen Extremely Flexible and High in Performance Das LVIS-ME200 Touch Display ist eine grafische Bedieneinheit mit Automationsfunktionen und Fernzugriff für BACnet/IP oder BACnet MS/TP Netzwerke. Sie bietet eine extrem flexible Benutzerschnittstelle mit beispielloser Palette an Funktionen. The LVIS-ME200 touch display is a graphical user interface with automation functions and remote access. The display for for BACnet/IP or BACnet MS/TP networks is an extremely flexible graphical user interface with an unprecedented range of functions. Bis zu 500 BACnet Server Objekte (Binary, Analog oder Multi-State) plus Scheduling, Alarming und Trending Objekte werden vom LVIS-ME200 Touch Display unterstützt. Ebenso ClientFunktionen wie WriteProperty, ReadProperty und COV Subscription. Kenndaten: 5,7”, 320x240 Pixels, 256 Farben/VGA. Die mitgelieferte Software gewährleistet eine unkomplizierte Konfiguration des Geräts. Vordefi nierte Funktionen vereinfachen das Erstellen von leicht zu bedienenden Menüs und grafischen Seiten, welche mit kundenspezifischen Bildern (JPG, BMP, TIF, animierte GIF, etc.) angepasst werden können. Dynamische Informationen werden als numerische Werte, wechselnde Symbole, Balkendiagramme oder Text dargestellt. LVIS-ME200 unterstützt Automationsfunktionen wie Scheduling, Alarming und Trending. Als lokaler AlarmServer kann es Datenpunkte überwachen. Als AlarmClient greift LVIS-ME200 auf Alarm Server Objekte entfernter Geräten zu, um die Alarmzustände am Display darzustellen. Scheduling beinhaltet lokale Zeitschaltfunktionen und die Möglichkeit, lokale wie auch entfernte Scheduling Objekte über das Display zu konfigurieren. Die Trendfunktion beinhaltet die grafische Darstellung und das Protokollieren von Informationen, welche via FTP Download zur Verfügung stehen. Touch Display LVIS-ME200 mit Automationsfunktionen. Touch Display LVIS-ME200 with automation functions. 54 BACnet Europe Journal 8 03/08 Mathematische Berechnungen und Funktionen sowie logischen Operatoren (Boolesche Algebra) werden unterstützt. Aktionsobjekte stehen zur Verfügung, um ereignisbedingt verschiedenste Aktionen auszulösen. Eine ereignisgesteuerte Email-Benachrichtigung informiert unmittelbar über den Systemstatus. LVIS-ME200 bietet Fernzugriff über TCP/IP. Der Display-Inhalt kann mittels VNC Protokoll (Virtual Network Computing) auf einem PC, PDA oder Smart Phone dargestellt werden. VNC ist plattformunabhängig und es gibt eine Vielzahl von VNC Clients für unterschiedliche Betriebssysteme. The LVIS-ME200 supports up to 500 BACnet server objects (binary, analog, or multi-state) plus scheduling, alarming and trending objects as well as client functions like WriteProperty, ReadProperty and COV Subscription. Characteristics: 5,7”, 320x240 pixels, 256 colors/VGA. The Configuration Software supplied with the unit guarantees a straight-forward configuration. Predefined functions simplify creating easy-to-use menu layouts and graphical pages using customized images (JPG, BMP, TIF, animated GIF, etc.). Dynamic information is shown in the form of numeric values, changing icons, bar graphs or text. LVIS-ME200 offers basic automation functions such as alarming, scheduling, and trending. As a local AlarmServer it can supervise data points. As an alarm client, LVIS-ME200 is accessing alarm server objects on remote devices to display the conditions on its display. Scheduling includes a local scheduling service as well as the possibility to configure several local and remote schedulers through display elements. The trending capability includes trend graphs and data logs. Logged information is available via FTP download. Mathematical operations as well as Boolean expressions are supported. Action objects are available to trigger various actions on special occasions. An event-driven email notification promptly informs about the system status. LVIS-ME200 provides remote access via TCP/IP. The content of the display can be displayed on a PC, PDA, or smart phone using the VNC (Virtual Network Computing) protocol. VNC is platform-independent and VNC viewers are available for many operating systems. LOYTEC electronics GmbH sales@loytec.com www.loytec.com Produkte Products BACnet-Watcher funktioniert ohne GLT Operates without BMS: BACnet-Watcher Der BACnet-Watcher ist ein universelles Tool für einfaches Bedienen, Beobachten und Protokollieren von BACnetObjekten ohne GLT-System-Einsatz und Konfigurationsarbeiten. BACnet-Watcher is a universal tool for easy using, monitoring and logging of BACnet objects without BMS system applications and configuration. Das System stellt die gesammelten Daten von allen BACnet-Devices im lokalen IP-Netzwerk über einen HTML-Webserver den Netzwerk-Clients zur Verfügung. Daher ist es betriebssystemneutral und mit handelsüblichen Webbrowsern bedienbar. Eine optimaleDarstellung wird zum Beispiel mit Firefox, Iceweasel, Opera und Safari erreicht. Eine übersichtliche und einfache Wertedarstellung/-Änderung komplexer Properties, beispielsweise Calendar, Schedule usw. ist über einfache Eingabemasken direkt in den Objektlisten möglich. Anlagenzustände können mittels farblicher Hervorhebung der Devices und Objekte mit Status „OffNormal“ zur schnellen Störerkennung unterschieden werden. Funktionalität und Eigenschaften Nach dem Start erfolgt automatisch ein Netzwerkscan mit Abfrage aller Devices und Ihren Objekten inklusive aller zur Diagnose wichtigen Eigenschaften. Über Objekt- COV-Wer teände rungen oder zyklisches Polling ausgewählter Devices wird das Prozessabbild permanent aktualisiert. Auf weiteren Bedienebenen/Seiten folgen die hierarchische Darstellung aller Devices, Objekte und Eigenschaften sowie eine Propertyliste je Objekt. Anlagenbezogenes Bedienen und Beobachten erfolgt über speicherbare Favoritenlisten. Das sind frei zusammenstellbare Objektlisten über alle Devices. Über die Bedienung von Menüs erfolgen die Speicherung sowie das Auslesen von Trendlog-Daten mit Darstellung als Textliste oder als graphisch aufbereitete Trendkurven. BACnet-Watcher. Ein BACnet-Watcher mit angeschlossenem BACnetController ist zum Testen erreichbar unter: www.bacnet-watcher.com, Login: Username: bacnet, Password: watcher Auf www.bacnet-watcher.com gibt es den BACnet-Watcher zum Testen. The BACnet Watcher for testing at www.bacnet-watcher.com The system makes the collected data of all BACnetdevices in the local IP network via a HTML-Webserver for the network clients available. Consequently it is operating system neutral and user friendly with the customary WEB browser. Excellent display is provided by Firefox, Iceweasel, Opera or Safari. Funktions and features After booting, BACnetWatcher automatically starts its diagnosis with a network scan of all important features on all devices and their objects. Via “COV (change of value)” or “periodic polling of selected devices” the process image will be updated permanently. On further user levels/pages a hierachical display of all devices, objects and features as well as a property list per object follows. A clear and easy value representation/ change of complex properties, e.g. Calendar-, Schedule etc. is via easy input masks possible directly in the object list. For a plant status or quick error detection the devices and objects with an OffNormal status are highlighted in colour. Plant related using and monitoring will be carried out via a storable favorite lists. These are free composable objectlists over all devices. Via using menus readout and storing of trendlog-data will be carried out and displayed as a textlist or graphical presentation (trend curves). A BACnet-Watcher with connected BACnet-Controller is reachable for testing via: hwww.bacnet-watcher.com, Login: Username: bacnet, Password: watcher INH-GmbH / HHO_Automation nhartleb@inh-hho.de www.hho-automation.de BACnet Europe Journal 8 03/08 55 neuberger. weishaupt gruppe Neuberger Gebäudeautomation GmbH & Co.KG Oberer Kaiserweg 6 D-91541 Rothenburg o.d.Tauber Telefon 09861/402-0 Telefax 09861/402-333 E-Mail: info@neuberger.net Internet: www.neuberger.net Gebäudeautomation. Offen in allen Ebenen Automatisch. Effizient. Neue Messe Stuttgart Bedarfsorientierte Gebäudeautomation Wollen Sie Unabhängigkeit, Flexibilität und größtmögliche Freiheit? Dann entscheiden Sie sich für Priva. Wolfgang Mielke Geschäftsführer Priva Building Intelligence GmbH Priva, national und international der Spezialist für Gebäudemanagementsysteme. Als Facility Manager, Gebäudeverwalter oder Gebäudeeigentümer wissen Sie, wie wichtig ein zukunftsorientiertes und (Energie-)kosteneffizientes Gebäudemanagementsystem ist. Der flexible und modulare Aufbau unserer Systeme eröffnet Ihnen Unabhängigkeit in der Bearbeitung, völlige Freiheit bei der Integration von Drittsystemen und Verwendung der Feldgeräte. Ein Netzwerk von zuverlässigen, qualifizierten Installationspartnern garantiert zusätzliche Betriebssicherheit. Mit den intelligenten Technologien von Priva alle haben Sie alle Optionen für die optimale Funktionalität Ihres Gebäu- demanagementsystems selbst in der Hand. Die Kostenentwicklung haben Sie im Griff und durch die Steigerung von Komfort und die Benutzerfreundlichkeit, wächst die Zufriedenheit der Nutzer. Suchen Sie ein Gebäudemanagementsystem, das Ihnen alle Freiheiten, Flexibilität und Unabhängigkeit garantiert? Dann ist Priva die optimale Wahl. The art of having control Priva Building Intelligence | Postbus 18 | 2678 ZG De Lier | T +31 (0)174-522 600 | F +31 (0)174-522 700 | sales.building@priva.nl | www.ikkiesvoorpriva.nl BACnet Interest Group Europe AHR Expo: BACnet beflügelt Export AHR Expo: BACnet boosts export Mitglieder der BIG-EU präsentierten Ihre Produkte auf der AHR-Expo 2008 in New York. Die traditionsreiche Messe für Heizung, Lüftung, Klimatisierung und Kühlung entwickelt sich zunehmend zum globalen Marktplatz. Members of BIG-EU presented their products at the AHR Expo 2008 in New York. The long-established trade fair for heating, ventilation, air-conditioning and refrigeration is rapidly becoming a global marketplace. Es war die größte AHR Expo seit ihrer Gründung vor 72 Jahren. Vom 22.-24. Januar trafen sich in New York 60.000 Fachbesucher und Aussteller aus 132 Ländern. Auch die Mitglieder der BIG-EU nutzen den amerikanischen Marktplatz zunehmend für ihren Export. Die Teilnahme war erstmals zentral durch MarDirect organisiert worden. So war ein vollständiges Servicepaket zu günstigen Konditionen möglich, messetypische Besonderheiten konnten frühzeitig berücksichtigt werden. Kieback&Peter präsentierte in New York die Gebäudeleittechnik Neutrino GLT, das Gebäudeautomationssystem DDC4000, aber auch den BusModulRegler BMR sowie Ventile und Stellantriebe. Plüth stellte vier native BACnet Controller für unterschiedliche Projektgrößen und die native BACnet GLT COSMOweb vor. Eine hohe Besucherdichte ermöglichte zahlreiche Kontakte in die USA, aber auch in andere Länder und Kontinente. Die ersten Vertriebserfolge wurden schon während der Messe gemeldet. Traditionell wird die AHR Expo in Verbindung mit den ASHRAE Winter Meetings veranstaltet. Das bot der BACnet Community wieder die Chance, den weltweiten BACnet Erfolg in gemeinsamen Treffen weiter zu entwickeln. Die Vertreter der BIG-EU sitzen im Normungsgremium SSPC 135. In ihrem Liaison Meeting beschlossen die BIG-EU und die amerikanische BACnet International weitere gemeinsame Schritte. Außerdem nahmen die Vertreter der BIG-EU geschlossen an der Mitgliederversammlung der BACnet international teil. Die nächste AHR Expo findet in Chicago statt, vom 26.-28. Januar 2009. Die ASHRAE Winter Meetings beginnen bereits am 24. Januar. It was the largest ever AHR Expo since its beginnings 72 years ago. From January 22 – 24, New York City was the rendezvous for 60,000 trade visitors and exhibitors from 132 countries. The BIG-EU members are also increasingly using this American marketplace to promote their exports. For the first time participation was organized centrally by MarDirect. This way an allround service package was possible at favorable conditions and the Die bisher größte AHR Expo fand im Januar in New York statt. The largest ever AHR Expo took place in New York City in January. expo special features could be taken into consideration in good time. The exhibits that were presented by Kieback&Peter included the Neutrino GLT Building management system, the Building Automation System DDC4000, but also the Bus Module Controller BMR, control valves and servodrives. Plueth presented four native BACnet Controllers for projects of various scales and the native BACnet GLT COSMOweb. The record-breaking visitor attendance not only paved the way for numerous contacts in the USA, but also in other countries and continents. First sales success reports were made before the show was over. Tradition has it that the AHR Expo is always held in con- junction with the ASHRAE Winter Meetings. This again gave the BACnet community the opportunity of advancing the world-wide success of BACnet during these get-togethers. BIG-EU is represented in the BACnet Committee SSPC 135. Further concerted measures were resolved during the liaison meeting between BIG-EU and American BACnet International. The BIG-EU representatives also attended the Annual General Meeting of BACnet International. The next AHR Expo will take place in Chicago, from January 26 – 28, 2009, with the ASHRAE Winter Meetings beginning on January 24. Bruno Kloubert Head of Marketing MarDirect kloubert@mardirect.de BACnet Europe Journal 8 03/08 57 SAMSON Normungsausschuss SSPC 135 Meeting In New York traf sich unter der Leitung von Bill Swan das BACnet Standing Standard Project Committee (SSPC 135) zum ASHRAE Winter Meeting. The SSPC 135 Meeting during the AHRAE Winter Meeting in New York was conducted by its chairman Bill Swan. Der BACnet Ausschuss empfahl die öffentliche Revision von zehn Ergänzungen des BACnet Standards. Von großem Interesse war die Ergänzung q, die darauf zielt, den BACnet Standart über drahtlose ZigBee Netzwerke zu tunneln. In verschiedenen Arbeitsgruppen verfolgte der BACnet Ausschuss die Zulassung von neun weiteren Ergänzungen. Addendum j ist eine solche Ergänzung, die die physikalische Zutrittskontrolle unterstützt. Ein weiteres Addendum, das für die öffentliche Revision vorbereitet wurde, ist Addendum i. Es unterstützt Beleuchtungsanwendungen. BACnet on board Das frei konfigurierbare Automationssystem TROVIS 6600 wächst mit den Anforderungen: Ob Kleinanlage, mittlere Gebäudegröße oder verteilte Liegenschaft, es ist für alle Fälle gerüstet. Mit einem breiten Spektrum weiterer Anwendungen setzt der BACnet Ausschuss seine Arbeit fort. Darunter fällt die Integration von Gebäuden und Energieversorgung, die Erarbeitung von Standardgeräteprofilen für die Gebäudeautomation, die Steuerung der Videoüberwachung und die Betriebsüberwachung für Aufzüge. The BACnet committee recommended public review for 10 addenda to the BACnet standard including Addendum q, to tunnel BACnet over ZigBee wireless networks. In other developments, the BACnet committee worked towards approval of nine additional addenda during the meeting. One such addendum is Addendum j, support for physical access control. Another addendum being prepared for public review is Addendum i, support for lighting applications. The BACnet committee is continuing to work on a broad range of other items such as integrating buildings and the energy utilities, developing standard profiles for various building automation devices, CCTV control, and elevator monitoring. Ob als Stand-Alone-Gerät oder im Verbund mit Partnersystemen über BACnet/IP – TROVIS 6600 entspricht dem aktuellen Stand der Technik: SAMSON hat BACnet durchgehend integriert und das Profil BACnet Building Controller (B-BC) und darüber hinausgehende Funktionen implementiert. A01075DE Der im System integrierte Web-Server ermöglicht den vollgrafischen Zugriff auf alle Anlagendaten, von jedem Ort zu jeder Zeit. Hohe Funktionalität wird durch Ferneinwahl, Datalogging und Alarmmanagement erreicht. SAMSON AG · MESS- UND REGELTECHNIK Weismüllerstraße 3 · 60314 Frankfurt am Main Telefon: 069 4009-0 · Telefax: 069 4009-1507 E-Mail: samson@samson.de Internet: http://www.samson.de Das BACnet Komitee ist international besetzt. The SSPC 135 is internationally represented. Werden Sie Mitglied der BIG-EU Become a Member of the BIG-EU Europäischer Interessenverband für offene Gebäudeautomation mit BACnet® European interest group for open building automation systems with BACnet® Acht Gründe für Ihre Mitgliedschaft: Eight reasons for becoming a member: 1. Netzwerk 1. Network Nutzen Sie die BACnet Kontakte zu Betreibern und Investoren, Planern und Herstellern, Systemhäusern, Anlagenerrichtern und Systemintegratoren in Europa! Nehmen Sie Verbindung zu den BACnet Interest Groups in Nordamerika, Australien, Asien und im Mittleren Osten auf! Tauschen Sie persönliche Erfahrungen aus in Arbeitsgruppen, Mitgliederversammlungen, bei Ausstellungen und in unseren Mail-Communities. 2. Podium für Produkte und Projekte Take advantage of the BACnet network of European contacts to get in touch with operators and investors, planners and suppliers, system vendors, plant engineers and system integrators! Get connected with the BACnet Interest Groups in North America, Australia, Asia and the Middle East! Exchange experiences with others in working groups and general meetings, at exhibitions and in our mail communities. 2. A podium for products and projects Mit unserem BACnet Europe Journal und unserem Internetauftritt www.big-eu.org bieten wir Plattformen für BACnet Botschaften aus Ihrem Unternehmen zur Entwicklung des BACnet Standards. Informieren Sie über Ihr Unternehmen und Ihre BACnet Produkte und stellen Sie Ihre Referenzprojekte vor. Neue Mitglieder präsentieren sich mit einem Kurzprofil. 3. Referenz gegenüber dem Kunden With our BACnet Europe Journal and our Internet presence at www.bigeu.org, we offer platforms for spreading the latest BACnet news from your company for the development of the BACnet Standard. Tell others about your company and your BACnet products and present your reference projects. New members introduce themselves with a short company profile. 3. A reference for your clients Weisen Sie sich mit einer Mitgliedschaft in der BIG-EU als kompetenter BACnet Partner Ihren Kunden gegenüber aus! 4. Informationen aus erster Hand As a BIG-EU member, you will present yourself to your clients as a qualified BACnet partner. 4. First hand information Sichern Sie sich einen Wissensvorsprung bei der Entwicklung von BACnet Produkten. Die BIG-EU steht im Austausch mit dem Standing Standard Project Committee SSPC 135 der ASHRAE und informiert ihre Mitglieder über Innovationen zum BACnet Standard. 5. Mitgestaltung der BACnet ISO-Norm Make sure that you are the first to know about the latest BACnet developments when designing your products. The BIG-EU is in close contact with the Standing Standard Project Committee SSPC 135 of ASHRAE and informs its members about innovations to the BACnet Standard. 5. Develop the BACnet ISO Standard Wir begleiten die Normenentwicklung und kommunizieren die Anforderungen unserer Mitglieder an den BACnet Standard. Mitglieder sind eingeladen, in den Marketing- und Technik-Arbeitsgruppen mitzuwirken und Ihre Erfahrungen einzubringen. 6. Beteiligung an BACnet Veranstaltungen We participate in the development of the BACnet ISO Standard and make sure that the requests of our members are heard. Members are invited to participate in the Working Groups Marketing and Technique and to share their experiences. 6. Participation in BACnet events Beteiligen Sie sich an unseren Gemeinschaftsständen, zum Beispiel auf der light+building in Frankfurt/M, und an unseren BACnet Fachtagungen. 7. Trainingsangebote Take part in our community stands, e.g. at the light+building in Frankfurt, and in our `BACnet days´. 7. Training Nehmen Sie unsere Trainingsangebote wahr und gestalten Sie diese aktiv mit. 8. Zentrale Geschäftsstelle Take advantage of our BACnet training and take an active role in its development. 8. Head Office Unsere Geschäftsstelle steht Ihnen jederzeit mit Informationen über die BIG-EU und unsere Leistungen zur Verfügung. If you require any further information about the BIG-EU and its services, please do not hesitate to contact our Head Office. Ja, ich interessiere mich für die Leistungen der BIG-EU. Bitte senden Sie mir detaillierte Informationen über eine Mitgliedschaft zu. I am interested in the BIG-EU’s services. Please send me further information about becoming a member. Name ....................................................................................... Land/Country ........................................................................... Firma/Company ........................................................................ E-Mail ....................................................................................... Straße Nr./Street No .................................................................. Tel. ........................................................................................... PLZ Ort/City/town sort/post code ............................................. .................................................................................................. Datum, Unterschrift/Date, signature Seite kopieren und faxen an / Please copy this page and fax it to: +49-2 31-42 78 67 32 BACnet Interest Group Europe Willkommen in der BIG-EU Welcome to the BIG-EU INH-GmbH / HHO_Automation Tel. +41-61-725-11-22 www.hho-automation.de Die Ingenieurgesellschaft INH GmbH / HHO_Automation entwickelt seit 1990 Hardwareund Software für Komponenten der Gebäudeautomatisierung und Fernwirktechnik. Komponenten zum GLT/ DDC-System PROSYS wurde seit 1994 entwickelt, mit zugehörigen Software-Produkte werden grundsätzlich eigenentwickelt und gepflegt. Seit 1994 gehören zum Lieferprogramm Entwicklungs-und Lieferleistungen für die strukturierte Systemintegration verschiedener DDC/SPS-Systeme und Bussysteme. Im Jahr 2007 wurde die Entwicklung verschiedener BACnet-Produkte aufgenommen. Die INH-GmbH erbringt Produktlieferleistungen und Dienstleistungen zur Ausführung von HLKSE-Projekten im Bereich Gebäudeautomatisierung, Fernwirktechnik, Versorgungstechnik, Betriebsüberwachung. Seit 2007 ist die INH-GmbH Solution Provider der WAGO-Kontakttechnik GmbH & Co.KG. In 1990 the engineer association/company INH GmbH / HHO _Automation is founded. Since then it presents a high performenced processing company in the hard- and software for components in building automation and telecontrol engineering. In the year 1994 started the processing of the components for the BMS/DDC system PROSYS, that are self-developed and maintained. The product range contains processing- and setup for the structured system integration of different/miscellaneous DDC/SPS systems and bus systems. In 2007 the company started with developing of various BACnet products. INH-GmbH performs strongly in product delivery, engineering services to execute HVAC projects in the area/field of building automation, telecontrol engineering, supply engineering/ building services engineering and plantcontrolling. INH GmbH is solution provider of the WAGO-Kontakttechnik GmbH & Co.KG. Aquametro AG Tel. +41-61-725-11-22 www.aquametro.com Aquametro AG produziert und vertreibt weltweit Durchfluss- und Energiemessgeräte für Energieversorger, für die Haustechnik und für Anwendungen in der Prozessindustrie. Seit 1928 steht Aquametro für Zählertradition - durch Generationen von Qualitätsprodukten und die Bereitstellung angewandter Lösungen. Das Bewusstsein für die Vielfalt der Bedürfnisse, die wir weltweit antreffen, prägt unser Verhalten. Kurze Ablesezeit, Reduktion der Installationsund Integrationskosten sowie quantitative und qualitative Auswertungen stehen dabei im Vordergrund. Aquametro produces and markets throughout the world flow meters and energy meters for supply industries, building management and applications in the process industries. From 1928 onwards, Aquametro has been synonymous with metering technology - through the many generations of quality products and practical solutions we have provided. We 60 BACnet Europe Journal 8 03/08 are continually aware of the variety of specific requirements needed throughout the world - whether technological, economical, ecological or cultural – and this determines the way we act. The priorities are the need for quick readout times; low installation and integration costs and high-quality data processing. Fritz-Haber-Institut der Max-Planck-GesellschaftTel: +49-30-8413-30 www.fhi-berlin.mpg.de Das Fritz-Haber-Institut der Max-Planck-Gesellschaft, gegründet 1911 als Kaiser-Wilhelm-Institut für Physikalische Chemie und Elektrochemie, ist eine weltweit bekannte Stätte der Forschung im Bereich der physikalischen Chemie allgemein, und der Untersuchung von physikalisch-chemischen Vorgängen an Oberflächen und Grenzflächen im Besonderen. Mit seiner Eingliederung in die Max-PlanckGesellschaft 1953 wurde es nach seinem ersten Direktor benannt. Das Institut verfügt über die Abteilungen Anorganische Chemie, Chemische Physik, Molekülphysik, Physikalische Chemie und Theorie. The Fritz-Haber-Institute, founded as „Kaiser-WilhelmInstitut für Physikalische Chemie und Elektrochemie“ in 1911 is a world-renowned institution for research in physical chemistry in general, and the investigation of physical/chemical processes at surfaces and interfaces in particular. Integrated into the Max-Planck-Society in 1953, it was named in honour of its fi rst director. The institute incorporates the five depart- ments, Inorganic Chemistry, Chemical Physics, Molecular Physics, Physical Chemistry, and Theory. Salzburg Research Forschungsgesellschaft mbH Tel. +43-662-2288-200 www. salzburgresearch.at Salzburg Research ist die Forschungsgesellschaft des Landes Salzburg und betreibt angewandte Forschung im Bereich der Informations- und Kommunikations-Technologien. Die Forschungsabteilung ANC beschäftigt sich mit zuverlässigen, performanten und robusten Netzwerktechnologien. Dazu zählen das Modellieren und das Messen der Übertragungsqualitäten im Internet („Quality-of-Service“) ebenso wie die Entwicklung von Kommunikationsinfrastrukturen für verteilte Embedded Systems.Salzburg Research leistet Beiträge zur Standardisierung der Kommunikationstechnologien, u.a. in der Gebäudeautomatisierung und im Bereich der Sicherheits-IT. Salzburg Research is the research company of the State of Salzburg and conducts applied research in the areas of information and communication technologies. The research departments ANC focuses on reliable, performing and robust network technologies. Thereby the modelling and monitoring of the data transmission qualities (“quality-of-service”) is as well part of our work as the development of communication infrastructures for distributed embedded systems. Salzburg Research contributes to the standardization of communication technologies, e.g. in the building automation and in the area of secure IT. Fachbuch „Energieeffizienz durch Gebäudeautomation“ Die Energieeffi zienz von Gebäuden ist „das“ zentrale Thema im gesamten Umfeld des Bauens. Unter dem Leitbegriff der Gesamtenergieeffi zienz gilt es dabei, die einzelnen Phasen im Prozess der Gebäudeerstellung, Planung, Errichtung, Betreibung, Wartung und Pflege, Renovierung und Abbruch, gemeinsam zu betrachten. Ausgangspunkt für die europäischen Normen und deutschen Gesetze zum Energiesparen im Gebäudesektor ist die „Richtlinie 2002/91/ EG des europäischen Parlaments und des Rates vom 16. Dezember 2002 über die Gesamtenergieeffi zienz von Gebäuden“. Daraus entstand die zum 1. Oktober 2007 in Kraft getretene Novelle der deutschen Energieeinsparverordung. Das vorliegende Buch gibt Hinweise und Anregungen, die Gesetze, Verwaltungsvorschriften und Normen, aber auch die Angaben der Systemhersteller effi zient umzusetzen. Anhand der Vorstellung ausgeführter Praxisbeispiele erfährt der Leser, inwieweit durch den Einsatz von Gebäudeautomation als „Leitgewerk“ die Energieeffi zienz gesteigert und die Betriebskosten gesenkt werden können. Ein einführendes und vertiefendes Fachbuch für Bauingenieure, Architekten, Planer, Errichter, Systemintegratoren, die verschiedenen Vertreter der einzelnen Gewerke, Investoren, Betreiber und Benutzer. Der Herausgeber Peter Fischer ist Professor für Informations- und Kommunikationstechnik am Fachbereich Informations- und Elektrotechnik der Fachhochschule Dortmund. Peter Fischer (Hrsg.), Energie- und Kosteneffizienz durch gezielte Gebäudeautomation ISBN 978-3-922420-16-3 Promotor Verlag 1. Aufl. 2008 42,00 Euro Innovation by integration Does your organisation enjoy the advantages of BACnet? Interoperable system integration; a one-time investment that provides supplier independence; no licensing costs and freedom to choose hardware technology. Remote access utilizing BACnet over Ethernet makes systems operation from any location a reality. The result: low-cost investment + optimal ease-of-use = an innovative building management system. System Integrators with Content Regel Partners B.V. Hogebrinkerweg 8 3871 KN Hoevelaken P.O. Box 86 3870 CB Hoevelaken T. +31 (0)33 254 48 48 F. +31 (0)33 254 48 44 info@regelpartners.nl www.regelpartners.nl Regel Partners does it right! BACnet Europe Journal 8 03/08 61 4- #ONTROLISJUSTATOUCHAWAY BACnet Kalender Calendar of BACnet Events !LARMING 3CHEDULING 4RENDING .OTIFICATION Datum Date Ort Location Veranstaltung Event Kontakt Information 06.11.04.2008 Frankfurt, D l+b 2008 BIG-EU Office, info@big-eu.org 23.24.04.2008 Mannheim, D BACnet/VDI Training: Gebäudeautomation mit BACnet Frank Schubert, MBS GmbH, Krefeld, D, frank.schubert mbssoftware.de // Hans R. Kranz, HAK-Ingenieurberatung Haustechnik Automation Kranz, Forst, D, hans.kranz vdi.de 03.06.2008 London, GB BACnet Forum London BIG-EU Office, info@big-eu.org 05.06.2008 Berlin, D BIG-EU EB / AB Meeting Prof. Peter Fischer, Fachhochschule Dortmund, D, fischer fhdortmund.de 05.06.2008 Berlin, D BIG-EU General Meeting Prof. Peter Fischer, Fachhochschule Dortmund, D, fi scher fhdortmund.de 06.06.2008 Berlin, D BIG-EU WG-M Meeting Christian Müller, Honeywell GmbH, Offenbach, D, christian. mueller honeywell.com 06.06.2008 Berlin, D BIG-EU WG-T Meeting René Quirighetti, Siemens Building Technologies Ltd., Zug, CH, rene.quirighetti siemens.com 18.19.08.2008 Frankfurt, D BACnet/VDI Training: Gebäudeautomation mit BACnet Frank Schubert, MBS GmbH, Krefeld, D, frank.schubert mbssoftware.de // Hans R. Kranz, HAK-Ingenieurberatung Haustechnik Automation Kranz, Forst, D, hans.kranz vdi.de September 2008 Vienna, A BACnet Forum Wien BACnet Forum Wien September 2008 Vienna, A BIG-EU EB / AB Meeting Prof. Peter Fischer, Fachhochschule Dortmund, D, fi scher fhdortmund.de September 2008 Vienna, A BIG-EU WG-M Meeting Christian Müller, Honeywell GmbH, Offenbach, D, christian. mueller honeywell.com September 2008 Vienna, A BIG-EU WG-T Meeting René Quirighetti, Siemens Building Technologies Ltd., Zug, CH, rene.quirighetti siemens.com 07.10.10.2008 Essen, D BACnet booth Security Essen BIG-EU Office, info@big-eu.org Octrober 2008 Milano, I BACnet Forum Milano BIG-EU Office, Dortmund, D, info@big-eu.org 23.27.11.2008 Dubai, UAE BACnet booth The Big 5 Show Dubai 2008 Bruno Kloubert, MarDirect GbR, Dortmund, D., kloubert@ mardirect.de 27.28.11.2008 Düsseldorf, D BACnet/VDI Training: Gebäudeautomation mit BACnet Frank Schubert, MBS GmbH, Krefeld, D, frank.schubert mbssoftware.de // Hans R. Kranz, HAK-Ingenieurberatung Haustechnik Automation Kranz, Forst, D, hans.kranz vdi.de Nov 08 Paris, F BACnet Forum Paris Association BACnet France, Paris, mercurio@mardirect.de 27.-28.11.08 Düsseldorf, D BACnet/VDI Training: Gebäudeautomation mit BACnet Frank Schubert, MBS GmbH, frank.schubert mbs-software. de // Hans R. Kranz, HAK-Ingenieurberatung, Forst, D hans.kranz@vdi.de 01.12.2008 Krefeld, D BIG-EU EB / AB Meeting Prof. Peter Fischer, Fachhochschule Dortmund, D, fi scher fhdortmund.de 02.12.2008 Krefeld, D BIG-EU WG-M Meeting Christian Müller, Honeywell GmbH, Offenbach, D, christian. Mueller honeywell.com 02.12.2008 Krefeld, D BIG-EU WG-T Meeting René Quirighetti, Siemens Building Technologies Ltd., Zug, CH, rene.quirighetti siemens. com 2EMOTE!CCESS YFX #ALCULATION ,6)3#ONTROL AND$ISPLAY0ANEL 4HEPANELSOLUTIONFOR"!#NET¸NETWORKSAND ,ON-ARK¸SYSTEMSWITHEMBEDDEDAUTOMATION FUNCTIONSREMOTEACCESSANDEMAILNOTIFICATION ,/94%#ELECTRONICS'MB("LUMENGASSE7IEN!USTRIA INFO LOYTECCOMs4ELs&AX ,6)3ISATRADEMARKOF,/94%#ELECTRONICS'MB(,ON-ARKANDTHE,ON-ARK,OGOAREMANAGEDGRANTEDANDUSEDBY,ON-ARK )NTERNATIONALUNDERALICENSEGRANTEDBY%CHELON#ORPORATION"!#NETISAREGISTEREDTRADEMARKOFTHE!MERICAN3OCIETYOF(EATING 2EFRIGERATINGAND!IR#ONDITIONING%NGINEERS)NC!3(2!% NETWORKSUNDERCONTROL 4- Whenever limitless building automation is under discussion, talk turns to BACnet. And if it has to be modular, extensible and energy efficient as well, talk turns to SAUTER. SAUTER EY-modulo 5: with BACnet IP. Energy efficient, open and economical – module for module for module. The modular, native BACnet stations of the SAUTER EY-modulo 5 series are the intelligent solution in every respect for any needs relating to building management. With its optimal function modules, integrated web connection and comfortable intelligent unitary control, SAUTER sets new standards. Because it is freely programmable, SAUTER EY-modulo 5 provides perfect system integration and smooth operation. Find out more about its versatility: www.sauter-controls.com Systems Components Services Facility Management Foto © Hans Neleman/zefa/Corbis … wir sehen uns. Light+Building 2008 Stand 9.1, E40 … see you there. Gut aufgestellt Well positioned … and optimally set. Even in tough situations Kieback&Peter’s DDC4000 automation system doesn’t work up a sweat. The operation of the DDC4200 automation station via touch screen is simple, clear and secure. This allows you to dedicate your time to what really matters. … und bestens eingestellt. Mit dem Automationssystem DDC4000 von Kieback&Peter kommen Sie selbst in brenzligen Situationen nicht ins Schwitzen. Die Bedienung der Automationsstation DDC4200 über Touchscreen ist einfach, transparent und sicher. So haben Sie Zeit, sich den wirklich wichtigen Dingen zu widmen. Journal 8 GmbH 03/08& Co. KG, 12347 Berlin, Germany, Tel.: +49 30 600 95-0, E-Mail: info@kieback-peter.de 64 BACnet Europe Kieback&Peter www.kieback-peter.de